IFRF- May 2012Inclined Burner Firing System Eliminates Flame ImpingementBy: Ashutosh Garg

www.heatflux.com 2

Inclined Burner Firing System

• Client facing flame impingement and high tube metal temperatures in radiant section

• FIS recommended inclined burner firing system to eliminate flame impingement

• Carry out CFD Modeling of the Burners and Radiant Section to demonstrate the benefit of inclined burner firing system

www.heatflux.com 3

Burners-Existing

• Forced draft gas fired ultra low burners

• 24 burners, 12 Numbers in each cell

• Normal firing rates- 4.9 MMkcal/hr

• Burner air pressure drop- 22.5 mmwc

• Burner to tube center clearance – 1500 mm

www.heatflux.com 4

Existing Burner Arrangement

EXISTING FLOOR & PLENUM ARRANGEMENT

www.heatflux.com 5

Inclined Firing System Burner Arrangement

www.heatflux.com 6

Heater Geometry for Base Case

Outlet

Radiant tubes

Reed wall

Fuel inlets Air inlets

• Fuel inlets are mentioned independently for primary and secondary tips (shown in the figure) i.e. fuel distributor is not modeled in the current case

www.heatflux.com 7

Inclined Firing System Modification

• In this modification burner was made 12’’ closer towards center i.e. the BCD was made 15 ft 3.75’’

• Burner is inclined 5 deg towards center

• Reed wall is removed in this model

8

Burner Geometry

Recirculation hole Burner tiles

Staged tip with 3 holes

www.heatflux.com

www.heatflux.com 9

Results of CFD Modeling

• Velocity Vectors• Temperature Contours-Elevation• Temperature Contours- Plan View• CO Contours – Plan View• Path lines by temperature• Iso surfaces at 2000 ppm ( flame boundaries)- top view and

elevation view-colored by temperature• Conclusion

www.heatflux.com 10

Velocity vectors (ft/s)Base Case

• Velocity vectors shows that it is moving away from center due to circulation at center

Circulation zone

50 ft

36 ft

19 ft

0 ftheight

in ft

www.heatflux.com 11

Velocity vectors (ft/s) at 45 ° Inclined Firing System

• Velocity vectors shows that flame is inclined towards center, this is due to no circulation formed at the center of heater

No Circulation zone

50 ft

36 ft

19 ft

0 ftheight

in ft

www.heatflux.com 12

Velocity vectors (ft/s) at 45 deg –Base case vs. Inclined Firing System

50 ft

36 ft

19 ft

0 ft

height in ft

www.heatflux.com 13

Temperature contours (°C) – Base Case

30° Angle 40° Angle 50° Angle 60° Angle

www.heatflux.com 14

Temperature Contours (°C) – Inclined Firing System

40° Angle 50° Angle30° Angle 60° Angle

• High temperature regions are concentration in the center of burner. No high temperature species is moving towards radiant tubes

www.heatflux.com 15

Temperature Contours (°F) at 45° Section- Base Case VS. Inclined Firing System

Base case Inclined Firing System

16

Temperature contours at different section (°F)- Base Case

At 5 ft At 10 ft

At 15 ft At 20 ftwww.heatflux.com

17

Temperature contours at different section (°F)- Inclined Firing System

At 5 ft from heater base At 10 ft

At 15 ft At 20 ft

Low temperature

regions

www.heatflux.com

www.heatflux.com 18

Temperature contours(°F) at 5ftsection- Base Case VS. Inclined Firing System

1

At 5 ft

Base case

At 5 ft

Inclined Firing System

www.heatflux.com 19

Temperature contours(°F) at 10 ft section- Base Case VS. Inclined Firing System

Base case Inclined Firing System

At 10 ft At 10 ft

20

CO mass fraction contours (PPM) at different sections – Base Case

1At 5 ft from heater base At 10 ft

At 15 ft At 20 ftwww.heatflux.com

www.heatflux.com 21

CO mass fraction contours (PPM) at different sections - Inclined Firing System

At 5 ft from heater basement At 10 ft

At 15 ft At 20 ft

www.heatflux.com 22

CO mass fraction contours (PPM) at 15 ft section- Base Case VS. Inclined Firing System

1

Base case

At 15 ft At 15 ft

Inclined Firing System

www.heatflux.com 23

Iso surfaces of 2000 PPM of CO colored by temperature (°F)- Base Case

• Top and front views shows that flame is interacting with radiant tubes

Top viewQuarter section

Flame on radiant tubes

Front view

www.heatflux.com 24

Iso surfaces of 2000 PPM of CO colored by temperature (°F)- Inclined Firing System

• Top view shows that flame is not interacting with radiant tubes• Front view shows how the flame is inclined towards center of heater

section

Top view

Quarter section

Front view

25

Iso surface of CO mf 2000 PPM colored by temperatures (°F) Base Case VS. Inclined Firing System

Base Case Inclined Firing System

Top Viewwww.heatflux.com

www.heatflux.com 26

Summary

• Base case has the recirculation region at center of heater, there by diverting the flow towards the radiant tubes.

• Inclined Firing System- has no recirculation zone between opposite burners there by no bending of flame is observed

• High temperatures are confined to center of heater • FIS recommends inclined firing system revamp of

burners and floor revamp.