Hughes Proprietary
HughesNet Remote Software Version 5.4.0.X Training
HughesNet Powered By Partner and Value Added Reseller (VAR)
HNTR-0032 Rev.1 03/12/2007 Hughes Proprietary2
All rights reserved. This publication and its contents are proprietary to HUGHES. No part of this publication may be reproduced in any form or by any means without the written permission of HUGHES, 11717 Exploration Lane, Germantown, Maryland 20876.
Copyright © 2007 HUGHES Proprietary
Send any questions about this course to CSTRAINING@hns.com and mark the subject line HNTR-0032 Rev.1.
Proprietary Notice
HNTR-0032 Rev.1 03/12/2007 Hughes Proprietary3
About this Course
This course is for HughesNet Powered By Partner’s and Value Added Reseller (VAR) Help Desk Agents who provide technical support to HughesNet remotes running 5.4.0.X softwareThe new diagnostic features in the 5.4.0.X software are used to enhance HughesNet remote on-site troubleshooting efforts when walking the customer through standard troubleshooting steps
HNTR-0032 Rev.1 03/12/2007 Hughes Proprietary4
Course Pre-requisites
Pre-requisites to learning diagnostic features of 5.4.0.X software– Basic trouble isolation processes and procedures for
HughesNet Remotes with• Diagnostic tools on the remote’s System Control
Center, and• Advanced troubleshooting tools on the Advanced
Statistics pages
HNTR-0032 Rev.1 03/12/2007 Hughes Proprietary5
Course Outline
I. Introduction to remote SoftwareA. Help Desk Agent’s trouble isolation procedureB. Trouble isolation functionalityC. Remotes running 5.4.0.X software D. 5.4.0.X software home page diagnosticsE. 5.4.0.X software advanced statistics diagnostics F. Automated problem detection
II. 5.4.0.X Software System Control Center FeaturesIII. 5.4.0.X Software Advanced Statistics Page Diagnostic FeaturesIV. Hourly History Troubleshooting ProceduresV. Resources
A. KB Articles and Troubleshooting Procedures B. Home Page DiagnosticsC. Advanced Page Diagnostics
VI. Appendix A – Terms and AcronymsVII. Appendix B – KB ArticlesVIII. Appendix C – 5.4.0.X Software Diagnostic MessagesIX. Change Log
HNTR-0032 Rev.1 03/12/2007 Hughes Proprietary6
Course Objectives
To provide the knowledge of how to use Software Version 5.4.0.X diagnostic featuresUpon completion, you will be able to: – Identify which software version is assigned to which
HughesNet remote – Understand and use the 5.4.0.X diagnostic feature
HNTR-0032 Rev.1 03/12/2007 Hughes Proprietary8
Help Desk Agent’s Trouble Isolation Procedure
When troubleshooting a customer’s problem Help Desk Agents will: 1. Ask the customer what they have determined so far, if
they have used the Diagnostic tools, then determine what problem they were able to isolate to (i.e., I cannot access the System Control Center) and what steps they have performed (restarted unit, ping test, etc.) and record their observations, do a little verification of their observations
2. Help Desk Agents will step the customer through the troubleshooting process using the diagnostic features within the System Control Center and the Advanced Statistics pages and follow standard troubleshooting procedures
HNTR-0032 Rev.1 03/12/2007 Hughes Proprietary9
Trouble Isolation Functionality
HughesNet provisions its remote software builds to provide data outputs to be used specifically for trouble isolation purposes5.4.0.X Software features an Automated Problem Detection System that allows the automatic collection of data from many different statistical data collection points within the HughesNet remoteThis course presents the trouble isolation functionality within the 5.4.0.X software and the available operational statistical data history– Problem Troubleshooting outputs available to the
customer– Help Desk Agent facing Advanced Statistics Diagnostic
outputs
HNTR-0032 Rev.1 03/12/2007 Hughes Proprietary10
Remotes Running 5.4.0.X Software
5.4.0.X Software builds are assigned as follows:– DW6000 – Version 5.4.0.16– DW7X00 Series – Version 5.4.0.28– HN7X00S Series – Version 5.4.0.28
HNTR-0032 Rev.1 03/12/2007 Hughes Proprietary11
5.4.0.X Software Home Page Diagnostics
Diagnostic Utilities links on the System Control Center Home page– Connectivity Test– Problem TroubleshootingProblem Troubleshooting– What the Diagnostic Messages Mean?
• Diagnostic Message List (Appendix C)• Diagnostic Messages links
HNTR-0032 Rev.1 03/12/2007 Hughes Proprietary12
5.4.0.X Software Advance Statistics Diagnostics
Hourly HistoryArchived RecordsIP Address StatsLAN1 StatsTTMP HistoryPer TPS HistoryCPU Usage StatsGenerate TrafficExpert Diagnostic Links on the Advanced Statistics Page– Ping Test link
HNTR-0032 Rev.1 03/12/2007 Hughes Proprietary13
Automated Problem Detection
Each problem detected by the remote is associated with a set of statistics– Each statistic, in turn, is associated with thresholds to
classify it as Good, Bad or Marginal – If all statistics included in a problem signature have
“Good” values, the problem is not indicated – If any of the statistics included in the signature is “Bad”,
the problem may get indicated– If any of the statistics in a problem signature have
“Marginal” values, the problem is indicated• For example, Stream-NAK-to-Ack percentage is
included in the signature for Uplink Errors• If the Stream-Nak-to-Ack percentage during a
specific time interval exceeds the “Bad” threshold, it shall cause “Uplink Errors” to be identified as an issue during that interval
HNTR-0032 Rev.1 03/12/2007 Hughes Proprietary15
Software Diagnostic Utilities
There is a new Problem Troubleshooting
link that is available to the customer from the System Control Center Home Page
HNTR-0032 Rev.1 03/12/2007 Hughes Proprietary16
Problem Troubleshooting
This feature is intended to include typical troubleshooting steps that can be used by the customer to allow faster and better troubleshooting on his own or under the guidance of a Help Desk AgentFor example:– The customer is provided a drop-down menu with typical
customer problems such as:• “Web Pages paint slowly”• “It takes a long time to download big files”
– Another drop-down menu with a time interval is provided• Last 15 minutes• 15-30 minutes ago
HNTR-0032 Rev.1 03/12/2007 Hughes Proprietary17
Problem Troubleshooting Steps
The customer selects a problem description that most resembles the problem being experienced (5 choices are available); a time frame in which the problem occurred; and conducts a diagnostic test that will provide a troubleshooting analysis whose output will direct the user to take some specific troubleshooting step(s)
Customer Troubleshooting Choices
HNTR-0032 Rev.1 03/12/2007 Hughes Proprietary18
Problem Troubleshooting Choices
The Five Problem Choices are:– My web pages paint slowly– I see red Xs or broken images on web pages– Big files download slowly– Takes a long time to send big email attachments– I cant browse any web site
HNTR-0032 Rev.1 03/12/2007 Hughes Proprietary19
Problem Troubleshooting Process
The customer’s problem and the time interval information is used to determine system problems that may be causing the problemThe detected system problems are then displayed as separate line items with appropriate help information as Diagnostic Messages for each problemIf no problem is detected the Help Desk Agent will use the knowledge base to conduct more advanced troubleshooting
HNTR-0032 Rev.1 03/12/2007 Hughes Proprietary20
Customer Problem – System Problem Mapping
Customer Problem Corresponding System Problem List
My web pages paint slowly Cabling/Antenna Pointing, Fair Access Policy, Outroute, Network Congestion, Uplink Errors, Slow Uplink, Web Acceleration - NOC, Web Acceleration - VSAT, DNS Acceleration - NOC, DNS Acceleration - VSAT, VSAT Internal, LAN
I see red Xs or broken images on web pages
LAN, Uplink Errors, Outroute, Web Acceleration - NOC, Web Acceleration - VSAT, DNS Acceleration - NOC, DNS Acceleration - VSAT, VSAT Internal
Big files download slowly LAN, Uplink Errors, Outroute, Fair Access Policy, Network Congestion, Web Acceleration - NOC, Web Acceleration - VSAT, VSAT Internal
Takes a long time to send big email attachments
Uplink Errors, Slow Uplink, Outroute, LAN, Cabling/Antenna Pointing, VSAT Internal, Network Congestion
I cannot browse any web sites
LAN, Cabling/Antenna Pointing, Outroute, Fair Access Policy, Uplink Errors, Web Acceleration - NOC, Web Acceleration - VSAT, DNS Acceleration - NOC, DNS Acceleration - VSAT, VSAT Internal
This table represents diagnosed customer problems mapped to system level problems
HNTR-0032 Rev.1 03/12/2007 Hughes Proprietary21
Diagnostic Message for “Cable/Antenna Pointing”:
Appendix C: 5.4.0.x Software Diagnostic Messages details all diagnostic messages
System Problems = Diagnostic Message Results
HNTR-0032 Rev.1 03/12/2007 Hughes Proprietary22
There are Thirteen possible diagnostic messages– Cabling/Antenna Pointing– Downlink– Uplink– Uplink Queuing– TCP Acceleration– IP Gateway– RTT– Web Acceleration [N]– Web Acceleration [I]– DNS Acceleration [N]– DNS Acceleration [I]– IDU– LAN
Software Diagnostic Messages
The Cabling/Antenna Pointing Diagnostic Message appears as:
Appendix C - 5.4.0.X SoftwareDiagnostic Messages display what the customer will view
HNTR-0032 Rev.1 03/12/2007 Hughes Proprietary23
5.4.0.X Software Advanced Statistics Page
Diagnostic Features
HNTR-0032 Rev.1 03/12/2007 Hughes Proprietary24
Gathering and Maintaining Problem Statistics
The remote gathers and maintains various statistics from different data points in the system at short interval, typically 5 minutes, and long intervals, typically 1 hourA problem is flagged in a time interval if the status of “at least” one of the statistics in the problem’s signature is Bad
HNTR-0032 Rev.1 03/12/2007 Hughes Proprietary25
Diagnostic Links on Advanced Statistics Page
Two categories of Diagnostics Links:– Main: Links
that are most commonly used for troubleshooting
– Expert: Links that are to be used only by Engineering
Main
Expert
HNTR-0032 Rev.1 03/12/2007 Hughes Proprietary26
Main Diagnostic Links
Hourly HistoryArchived RecordsIP Address StatsLAN1 StatsTTMP HistoryPer TPS HistoryCPU Usage StatsGenerate Traffic
HNTR-0032 Rev.1 03/12/2007 Hughes Proprietary27
Hourly History Link
Green check mark means that the module status was ACCEPTABLE Red X mark means that the module status was BAD in that monitoring interval Black exclamation mark (in yellow background) means that the module status was MARGINAL The Hourly History link shows the problems detected in each hour interval in the past 24 hours
Hourly System Problem History
HNTR-0032 Rev.1 03/12/2007 Hughes Proprietary28
Archived Records Link
The Archived Records page provides diagnostics reports from previous days that are saved to the remote’s flash disk
Engineering will pull these reports from time to time to review the saved historical diagnostic information
When instructed Help Desk Agents will either click the Save System History button or instruct the customer to do so
HNTR-0032 Rev.1 03/12/2007 Hughes Proprietary29
Expert Folder
Links under the Expert folder are for more detailed debuggingThey provide more detailed module level statistics and other utilities that are only expected to be used by EngineeringPing Test link provides access to a ping utility tool
HNTR-0032 Rev.1 03/12/2007 Hughes Proprietary30
Ping TestThe Ping Test utility allows the user to initiate pings from within the remote
It provides the following links:– Ping Host: This link allows the user to ping
a specific host IP address– It comes filled with default values for various
parameters required for the ping test– The host field should contain the IP address
of the host to be pinged, pinging hosts using their domain name is not currently supported
HNTR-0032 Rev.1 03/12/2007 Hughes Proprietary31
Ping Test, ContinuedThere are two types of ping tests – Host Is Alive – sends 5 simultaneous ping request packets without
any inter request delay to the host, the host is considered alive if response is received to even one of the ping requests
– The number of echo requests parameter is ignored while doing a “host is alive” type test
– Link Health – sends the configured number of ping request packets with the configured inters request delay
– This is typically used to check the health of link by sending a few ping packets and looking at the results to see if there were any timeouts and the minimum/maximum and average ping response times
HNTR-0032 Rev.1 03/12/2007 Hughes Proprietary32
Ping Test, ContinuedA ping test can be repeated by specifying a timeout value in the “repeat test after” field– This field can be left empty if the test is not to be
repeated– If a timeout value of less than 10ms is configured for
any of the timeout fields then the ping test utility internally sets them to 10ms.
HNTR-0032 Rev.1 03/12/2007 Hughes Proprietary34
Hourly History Page = Timely Diagnostic Data
Hourly History is the source of historical data that Help Desk Agents will always use when troubleshooting HughesNet remotes running 5.4.0.X SoftwareFollowing is an explanation of how the Hourly History page functions as well as instructions as to what Help Desk Agents are to do when using this page
HNTR-0032 Rev.1 03/12/2007 Hughes Proprietary35
Hourly History
The Hourly History link shows the problems detected in each hour interval in the past 24 hours
Clicking on the images (Red X, Green Check etc) shows up the module/system statistics for that monitoring interval
Double Clicking the Green Check mark shows all statistics being monitored by the software
Hourly System Problem History
HNTR-0032 Rev.1 03/12/2007 Hughes Proprietary36
Statistics being monitored by the software include: System Level
Diagnostics Transport Layer
Diagnostic Statistics Address Statistics PEP Diagnostic
Statistics DNS Diagnostic
Statistics Turbopage
Diagnostic Statistics VSAT Internal
Diagnostic Statistics CPU Usage (percent
of monitoring interval)
LAN Traffic Activity Web Traffic
Response Time Statistics
Cable/Antenna Pointing Green Check mark
HNTR-0032 Rev.1 03/12/2007 Hughes Proprietary37
The results of clicking on a Red X mark is demonstrated here In this case, Uplink
Queuing Errors have a problem
Only the statistics that are determined to be outside predetermined parameters are displayed as “BAD” and/or with an asterisk (*)
Help Desk Agents are to note all “Bad” and/or with an asterisk parameters into the trouble ticket along with the values displayed
Uplink Queuing Errors Red X mark
Monitored statisticalinformation
showing BAD and/or *
HNTR-0032 Rev.1 03/12/2007 Hughes Proprietary38
Associating Rx and Tx Code Problems to Hourly History
Tx and Rx Codes appear on the System Control Center System Status page
CSRs can associate these codes to one of two “Problem” fields on the Hourly History page
Rx Code errors will be associated to the Cabling/Antenna Pointing “Problem” field
Tx Code errors will be associated to the Uplink “Problem” field
If either code shows a problem, more in depth troubleshooting may be performed by investigating any Red X in either of these two “Problem” fields Hourly System Problem History
HNTR-0032 Rev.1 03/12/2007 Hughes Proprietary40
User Guides and KB Articles
KB Articles in the Knowledgebase SystemStandard Troubleshooting Procedures– Customer perceived problem and error messages
• System Control Center• Advance Statistics Pages
HNTR-0032 Rev.1 03/12/2007 Hughes Proprietary42
Terms and Acronyms
Acronym Definition
IRU Indoor Receive Unit managing all Inroute data traffic
GWU Gateway Unit managing all data traffic between the IRU and ITU and network interfaces to the GWU
ODU Outdoor Unit comprising of all Antenna LNB, Transmitter, Antenna Pointing and Cabling configurations
SHU Self Hosted Unit that comprising of an IRU, ITU and GWU along with phone and network interfaces depending on the SHU build
SCC System Control Center page displayed from the SHU’s Internal Web Server allowing views of the remote’s diagnostic outputs
Rx and Tx Codes Receive and Transmit signal status organized in a numerical code system with associated definitions to be used for trouble isolation purposes. There are Nine Rx Codes and Twenty Seven Tx Codes
Advanced Configuration and Statistics
The page displayed from the SHU’s Internal Web Server allowing advanced views of the remote’s diagnostic outputs
HNTR-0032 Rev.1 03/12/2007 Hughes Proprietary44
5.4.0.X KB Articles
KB Article Title
3504 How to Access the System Control Center (Software Version 5.4.0 and Above)
3506 Reference: The System Control Center (Software Version 5.4.0 and Above)
3518 How to Use the Browsing Optimization Utility in the System Control Center (Software Version 5.4.0 and Above)
3521 Problem Troubleshooting via the System Control Center (Software Version 5.4.0 and Above)
3522 How to Test for Connectivity via the System Control Center (Software Version 5.4.0 and Above)
3545 How to Access Advanced Configuration and Statistics (Software Version 5.4.0 and Above)
3551 Troubleshoot Line-of-Sight Issues
3552 Troubleshoot Weather Issues
3553 How to Power Cycle a HughesNet Remote (Software Version 5.4.0 and Above)
3554 How to Ping a HughesNet Remote (Software Version 5.4.0 and Above)
HNTR-0032 Rev.1 03/12/2007 Hughes Proprietary46
Thirteen Possible Diagnostic Messages
Cabling/Antenna PointingDownlinkUplinkUplink QueuingTCP AccelerationIP GatewayRTTWeb Acceleration [N]Web Acceleration [I]DNS Acceleration [N]DNS Acceleration [I]IDULAN
HNTR-0032 Rev.1 03/12/2007 Hughes Proprietary60
Change Log
DATE SLIDE NO. CHANGE
03.07.07 10 Changed 2 bullets to reflect latest software build number for DW7000 and HN7000S family of remotes
03.07.07 25, 26, 27, 28, 30, 31, 32, 35 and
38
Updated graphics to reflect 5.4.0.28 software views
03.07.07 All Slides Removed any reference to “Recent History” link