HPE FlexFabric 5940 Switch Series data sheet · Data eet Page 3 • Troubleshooting – Ingress and...

Preview:

Citation preview

Data sheet

Key features

•L2/L3VXLANandEVPNsupportforvirtualizedenvironments

•OpenFlowsupportforinvestmentprotectionandSDNenvironments

•High-density10GbE,40GbEwith40Gor100Guplinkforspineandleafdeployments

•UnifymanagementofvirtualandphysicalnetworkwithVEPAandIMC

•HPEFlexFabricNetworkAnalyticssolutioncapabilityforrealtimemicroburstdetection

Product overview

TheHPEFlexFabric5940SwitchSeriesisafamilyofhigh-performanceandlow-latency10GbE,40GbEtop-of-rack(ToR)datacenterswitches.Theswitchseriesalsoincludes100Gand40GuplinktechnologyandispartoftheHPEFlexFabricdata center solution,whichisacornerstoneoftheFlexNetworkarchitecture.

TheFlexFabric5940SwitchSeriesisideallysuitedfordeploymentattheaggregationorserveraccesslayeroflargeenterprisedatacenters,oratthecorelayerofmedium-sizedenterprises.

Withtheincreasedpaceofdeployingvirtualizedapplications,adoptingsoftware-definednetworking,andtheserver-to-servertraffic,manydatacentersnowrequirespineandToRswitchinnovationsthatwillmeettheirrequirements.TheHPEFlexFabric5940isoptimizedtomeettheincreasingrequirementsforhigher-performanceserverconnectivity,convergenceofEthernetandstoragetraffic,thecapabilitytohandlevirtualenvironments,andlowlatency.

Features and benefits

Quality of Service (QoS)•PowerfulQoSfeatures

–Flexible queue schedulingIncludingstrictpriority(SP),WRR,WDRR,WFQ,SP+WRR,SP+WDRR,SP+WFQ,configurablebuffer,timerange,queueshaping,CARwith8Kbpsgranularity

HPE FlexFabric 5940 Switch Series

Page 2Data sheet

–Packet filtering and remarkingPacketfilteringatL2throughL4;flowclassificationbasedonsourceMACaddress,destinationMACaddress,sourceIP(IPv4/IPv6)address,destinationIP(IPv4/IPv6)address,port,protocol,andVLAN

Data center optimized•Flexible high-port density

The5940SwitchSeriesenablescustomerstoscaletheirserver-edge10/40/100GbEToRdeploymentstonewheightswithhigh-density48fixedx10GbEwith6portsof40G;48fixedx10GbEwith6portsof100G;and32fixedx40GbE,alldeliveredina1RUdesign.The594032portsof40Gswitchcanalsobeconfiguredasa96x10GbEportdevicebyusinga40Gto10GbEsplittercablethatcanturn24ofthe40GbEportsintofour10GbEports.The48-portmodelscomeinSFP+orBASE-T.

The5940SwitchSeriesalsoincludes2-slot(1RU)and4-slot(2RU)optionswhichallowforcustomizationofportsattheToR.Moduleoptionsinclude8x40Gports;2x40Gand2x100Gports;24x10G(SFP+orBASE-T)with2x40Gports(MACsecandFCoptionsavailable).

•High-performance switchingCut-throughandnon-blockingarchitecturedeliverslowlatency(~1microsecondfor10GbE)forverydemandingenterpriseapplications;theswitchdelivershigh-performanceswitchingcapacityandwire-speedpacketforwarding

•Higher scalabilityHPEIntelligentResilientFabric(IRF)technologysimplifiesthearchitectureofserveraccessnetworks;uptonineHPE5940switchescanbecombinedtodeliverunmatchedscalabilityofvirtualizedaccesslayerswitchesandflattertwo-tiernetworksusingIRF,whichreducescostandcomplexity

•Advanced modular operating systemComwarev7software’smodulardesignandmultipleprocessesbringnativehighstability,independentprocessmonitoring,andrestart;theOSalsoallowsindividualsoftwaremodulestobeupgradedforhigheravailabilityandsupportsenhancedserviceabilityfunctionssuchashitlesssoftwareupgrades

•Reversible airflowEnhancedfordatacenterhot-coldaisledeploymentwithreversibleairflow—foreitherfront-to-backorback-to-frontairflow

•Redundant fans and power suppliesInternalredundantandhot-pluggablepowersuppliesanddualfantraysenhancereliabilityandavailability

•Lower OPEX and greener data centerProvidereversibleairflowandadvancedchassispowermanagement

•Jumbo framesWithframesizesofupto10,000bytesonGigabitEthernetand10-Gigabitports,allowshigh-performanceremotebackupanddisasterrecoveryservicestobeenabled

•VXLAN hardware supportVXLANL2andL3gatewaysupportforupto4Ktunnels

•Dynamic VXLAN configurationOVSDBandML2supportfordynamicVXLANconfiguration

•EVPNControlplaneprotocolforVXLANbasedonindustrystandards.ItenablesL2andL3control-planelearningofend-hostreachabilityinformation,enablingorganizationstoscaletheirVXLANinfrastructurebetter.IntegrationwithOpenStack®Neutronplug-inforoverlayautomationororchestration

Manageability•TheHPEFlexFabricNetworkAnalytics

solutionwithreal-timetelemetryanalysisprovidesinsightintodatacenternetworkoperation

–Tracksalltheaccountingassociatedwiththeadmissionandallocationprocessofallthebuffersandqueuesacrosstheingressandegressports

–Microburstcongestiondetection

–Richcongestionanalytics

–Buffercongestionstateandstatistics

–Formoreinformation,seetheHPE FlexFabric Network Analytics data sheetandHPE FlexFabric Network Analytics white paper.

•Full-featured consoleProvidescompletecontroloftheswitchwithafamiliarCLI

Page 3Data sheet

•Troubleshooting

– Ingressandegressportmonitoringenablenetworkproblemsolving

–TracerouteandpingEnabletestingofnetworkconnectivity

•Multiple configuration filesAllowsmultipleconfigurationfilestobestoredtoaflashimage

•SNMPv1, v2c, and v3Facilitatescentralizeddiscovery,monitoring,andsecuremanagementofnetworkingdevices

•Out-of-band interfaceIsolatesmanagementtrafficfromuserdataplanetrafficforcompleteisolationandtotalreachability,nomatterwhathappensinthedataplane

•Remote configuration and management Deliveredthroughasecurecommand-lineinterface(CLI)overTelnetandSSH;role-basedaccesscontrol(RBAC)providesmultiplelevelsofaccess;configurationrollbackandmultipleconfigurationsontheflashprovideeaseofoperation;remotevisibilityisprovidedwithsFlow®andSNMPv1,v2,orv3,andisfullysupportedinHPEIntelligentManagementCenter(IMC)

•ISSU and hot patching InServicesSoftwareUpgrade(ISSU)providessoftwareupgradesandhitlesspatchingofthemodularoperatingsystem

•Auto-configuration ProvidesautomaticconfigurationviaDHCPauto-configuration

•NTP, SNTPSynchronizestimekeepingamongdistributedtimeserversandclients;supportfornetworktimeprotocol(NTP),securenetworktimeprotocol(SNTP)

Resiliency and high availability•IRF technology

EnablesanHPEFlexFabrictodeliverresilient,scalable,andsecureddatacenternetworksforphysicalandvirtualizedenvironments;groupsuptonineHPE5940switchesinanIRFconfiguration,allowingthemtobeconfiguredandmanagedasasingleswitchwithasingleIPaddress;simplifiesToRdeploymentandmanagement,reducingdatacenterdeploymentandoperatingexpenses

•IEEE 802.1w Rapid Convergence Spanning Tree ProtocolIncreasesnetworkuptimethroughfasterrecoveryfromfailedlinks

•IEEE 802.1s Multiple Spanning TreeProvideshighlinkavailabilityinmultipleVLANenvironmentsbyallowingmultiplespanningtrees

•Virtual Router Redundancy Protocol (VRRP)Allowsgroupsoftworouterstobackeachotherupdynamicallytocreatehighlyavailableroutedenvironments

•Hitless patch upgradesAllowspatchesandnewservicefeaturestobeinstalledwithoutrestartingtheequipment,increasingnetworkuptimeandfacilitatingmaintenance

•Ultrafast protocol convergence (< 50 ms) with standard-based failure detectionBidirectionalForwardingDetection(BFD)enableslinkconnectivitymonitoringandreducesnetworkconvergencetimeforRIP,OSPF,BGP,IS-IS,VRRPandIRF

•Device Link Detection Protocol (DLDP)Monitorslinkconnectivityandshutsdownportsatbothendsifunidirectionaltrafficisdetected,preventingloopsinSTP-basednetworks

•Graceful restartAllowsrouterstoindicatetootherstheircapabilitytomaintainaroutingtableduringatemporaryshutdownandsignificantlyreducesconvergencetimesuponrecovery;supportsOSPF,BGP,andIS-IS

Layer 2 switching•MAC-based VLAN

Providesgranularcontrolandsecurity;usesRADIUStomapaMACaddress/usertospecificVLANs

•Address Resolution Protocol (ARP)Supportsstatic,dynamic,andreverseARPandARPproxy

•IEEE 802.3x Flow ControlProvidesintelligentcongestionmanagementviaPAUSEframes

•Ethernet Link AggregationProvidesIEEE802.3adLinkAggregationofupto16portspergroupandupto128groups;supportforLACP,LACPLocalForwardingFirst,andLACPshorttimeprovidesafast,resilientenvironmentthatisidealforthedatacenter

Page 4Data sheet

•Spanning Tree Protocol (STP)SupportsSTP(IEEE802.1D),RapidSTP(RSTP,IEEE802.1w),andMultipleSTP(MSTP,IEEE802.1s)

•VLAN support Providessupportfor4,094VLANsbasedonport,MACaddress,IPv4subnet,protocol,andguestVLAN;supportsVLANmapping

•IGMP supportProvidessupportforIGMPSnooping,Fast-Leave,andGroup-Policy;IPv6IGMPSnoopingprovidesL2optimizationofmulticasttraffic

•DHCP supportProvidesfullDHCPSnoopingsupportforDHCPSnoopingOption82,DHCPRelayOption82,DHCPSnoopingtrust,andDHCPSnoopingitembackup

L3 services•Address Resolution Protocol

DeterminestheMACaddressofanotherIPhostinthesamesubnet;supportsstaticARPs;gratuitousARPallowsdetectionofduplicateIPaddresses;proxyARPallowsnormalARPoperationbetweensubnetsorwhensubnetsareseparatedbyaL2network

•Dynamic Host Configuration Protocol (DHCP)SimplifiesthemanagementoflargeIPnetworksandsupportsclientandserver;DHCPRelayenablesDHCPoperationacrosssubnets

•Operations, administration, and maintenance (OAM) supportProvidessupportforConnectivityFaultManagement(IEEE802.1ag)andEthernetintheFirstMile(IEEE802.3ah);providesadditionalmonitoringthatcanbeusedforfastfaultdetectionandrecovery

L3 routing•VRRP and VRRP Extended

Allowsquickfailoverofrouterports

•Policy-based routingMakesroutingdecisionsbasedonpoliciessetbythenetworkadministrator

•Equal-Cost Multipath (ECMP) Enablesmultipleequal-costlinksinaroutingenvironmenttoincreaselinkredundancyandscalebandwidth

•L3 IPv4 routingProvidesroutingofIPv4atmediaspeed;supportsstaticroutes,RIPandRIPv2,OSPF,BGP,andIS-IS

•Open shortest path first (OSPF)Deliversfasterconvergence;usesthislink-stateroutingInteriorGatewayProtocol(IGP),whichsupportsECMP,NSSA,andMD5authenticationforincreasedsecurityandgracefulrestartforfasterfailurerecovery

•Border Gateway Protocol 4 (BGP-4) DeliversanimplementationoftheExteriorGatewayProtocol(EGP)utilizingpathvectors;usesTCPforenhancedreliabilityfortheroutediscoveryprocess;reducesbandwidthconsumptionbyadvertisingonlyincrementalupdates;supportsextensivepoliciesforincreasedflexibility;scalestoverylargenetworks

•Intermediate system to intermediate system (IS-IS)UsesapathvectorIGP,whichisdefinedbytheISOorganizationforIS-ISroutingandextendedbyIETFRFC1195tooperateinbothTCP/IPandtheOSIreferencemodel(IntegratedIS-IS)

•Static IPv6 routingProvidessimplemanuallyconfiguredIPv6routing

•Dual IP stackMaintainsseparatestacksforIPv4andIPv6toeasethetransitionfromanIPv4-onlynetworktoanIPv6-onlynetworkdesign

•Routing Information Protocol next generation (RIPng)ExtendsRIPv2tosupportIPv6addressing

•OSPFv3ProvidesOSPFsupportforIPv6

•BGP+ExtendsBGP-4tosupportMultiprotocolBGP(MBGP),includingsupportforIPv6addressing

•IS-IS for IPv6ExtendsIS-IStosupportIPv6addressing

•IPv6 tunnelingAllowsIPv6packetstotraverseIPv4-onlynetworksbyencapsulatingtheIPv6packetintoastandardIPv4packet;supportsmanuallyconfigured,6to4,andIntra-SiteAutomaticTunnelAddressingProtocol(ISATAP)tunnels;isanimportantelementforthetransitionfromIPv4toIPv6

Page 5Data sheet

•Policy routing Allowscustomfiltersforincreasedperformanceandsecurity;supportsACLs,IPprefix,ASpaths,communitylists,andaggregatepolicies

•Bidirectional Forwarding Detection (BFD)EnableslinkconnectivitymonitoringandreducesnetworkconvergencetimeforRIP,OSPF,BGP,IS-IS,VRRPandIRF

•Multicast Routing PIM Dense and Sparse Modes Providesrobustsupportofmulticastprotocols

•L3 IPv6 routingProvidesroutingofIPv6atmediaspeed;supportsstaticrouting,RIPng,OSPFv3,BGP-4+forIPv6,andIS-ISv6

Additional information•Green IT and power

Improvesenergyefficiencythroughtheuseofthelatestadvancesinsilicondevelopment;shutsoffunusedports,andutilizesvariablespeedfans,reducingenergycosts

Management•USB support

–File copyAllowsuserstocopyswitchfilestoandfromaUSBflashdrive

•Port mirroringEnablestrafficonaporttobesimultaneouslysenttoanetworkanalyzerformonitoring

•RemoteconfigurationandmanagementIsavailablethroughaCLI

•IEEE 802.1AB Link Layer Discovery Protocol (LLDP)Advertisesandreceivesmanagementinformationfromadjacentdevicesonanetwork,facilitatingeasymappingbynetworkmanagementapplications

•sFlow (RFC 3176)ProvidesscalableASIC-basedwirespeednetworkmonitoringandaccountingwithnoimpactonnetworkperformance;thisallowsnetworkoperatorstogatheravarietyofsophisticatednetworkstatisticsandinformationforcapacityplanningandreal-timenetworkmonitoringpurposes

•Command authorizationLeveragesRADIUStolinkacustomlistofCLIcommandstoanindividualnetworkadministrator’slogin;anaudittraildocumentsactivity

•Dual flash imagesProvidesindependentprimaryandsecondaryoperatingsystemfilesforbackupwhileupgrading

•Command-line interfaceProvidesasecure,easy-to-useCLIforconfiguringthemoduleviaSSHoraswitchconsole;providesdirectreal-timesessionvisibility

•LoggingProvideslocalandremoteloggingofeventsviaSNMP(v2candv3)andsyslog;provideslogthrottlingandlogfilteringtoreducethenumberoflogeventsgenerated

•Management interface control Providesmanagementaccessthroughamodemportandterminalinterface,aswellasin-bandandout-of-bandEthernetports;providesaccessthroughterminalinterface,Telnet,orSSH

•Industry-standard CLI with a hierarchical structureReducestrainingtimeandexpenses,andincreasesproductivityinmultivendorinstallations

•Management securityRestrictsaccesstocriticalconfigurationcommands;offersmultipleprivilegelevelswithpasswordprotection;ACLsprovideTelnetandSNMPaccess;localandremotesyslogcapabilitiesallowloggingofallaccess

•Information centerProvidesacentralrepositoryforsystemandnetworkinformation;aggregatesalllogs,traps,anddebugginginformationgeneratedbythesystemandmaintainstheminorderofseverity;outputsthenetworkinformationtomultiplechannelsbasedonuser-definedrules

•Network managementHPE IMCcentrallyconfigures,updates,monitors,andtroubleshoots

•Remote intelligent mirroringMirrorsingress/egressACL-selectedtrafficfromaswitchportorVLANtoalocalorremoteswitchportanywhereonthenetwork

Page 6Data sheet

Security•Access control lists (ACLs)

ProvideIPL3filteringbasedonsourceordestinationIPaddressorsubnetandsourceordestinationTCP/UDPportnumber

•RADIUS/TACACS+Easesswitchmanagementsecurityadministrationbyusingapasswordauthenticationserver

•Secure ShellEncryptsalltransmitteddataforsecureremoteCLIaccessoverIPnetworks

•IEEE 802.1X and RADIUS network loginsControlsport-basedaccessforauthenticationandaccountability

•Port securityAllowsaccessonlytospecifiedMACaddresses,whichcanbelearnedorspecifiedbytheadministrator

Convergence•LLDP Media Endpoint Discovery

DefinesastandardextensionofLLDPthatstoresvaluesforparameterssuchasQoSandVLANtoconfigurenetworkdevicesautomaticallysuchasIPphones

Warranty and support•1-year warranty

Seehpe.com/networking/warrantysummaryforwarrantyandsupportinformationincludedwithyourproductpurchase.

•Software releases Tofindsoftwareforyourproduct,refertohpe.com/networking/support;fordetailsonthesoftwarereleasesavailablewithyourproductpurchase,refertohpe.com/networking/warrantysummary.

Page 7Data sheet

HPE FlexFabric 5940 48SFP+ 6QSFP+ Switch (JH395A)

HPE FlexFabric 5940 32QSFP+ Switch (JH396A)

HPE FlexFabric 5940 48XGT 6QSFP+ Switch (JH394A)

I/O ports and slots 48fixed1000/10000SFP+ports6QSFP+40GbEports

32QSFP+40GbEports 48 1/10GBASE-Tports6QSFP+40GbEports

Additional ports and slots 1RJ-45and1MiniUSB2.0serialconsoleport1RJ-45out-of-bandmanagementport1USB2.0

1RJ-45and1MiniUSB2.0serialconsoleport1RJ-45out-of-bandmanagementport1USB2.0

1RJ-45and1MiniUSB2.0serialconsoleport1RJ-45out-of-bandmanagementport1USB2.0

Power supplies 2powersupplyslots1minimumpowersupplyrequired(orderedseparately)

2powersupplyslots1minimumpowersupplyrequired(orderedseparately)

2powersupplyslots1minimumpowersupplyrequired(orderedseparately)

Fan tray 2fantrayslotsThecustomermustorderfantrays,asfantraysarenotincludedwiththeswitch.Thissystemrequirestwosame-directionairflowfantraystofunctionproperly.Thesystemshouldnotbeoperatedwithonlyonefantrayformorethan24hours.Thesystemshouldnotbeoperatedwithoutafantrayformorethantwominutes.Thesystemshouldnotbeoperatedoutsideofthetemperaturerangeof32°F(0°C)to113°F(45°C).Failuretocomplywiththeseoperatingrequirementsmayvoidtheproductwarranty.

2fantrayslotsThecustomermustorderfantrays,asfantraysarenotincludedwiththeswitch.Thissystemrequirestwosame-directionairflowfantraystofunctionproperly.Thesystemshouldnotbeoperatedwithonlyonefantrayformorethan24hours.Thesystemshouldnotbeoperatedwithoutafantrayformorethantwominutes.Thesystemshouldnotbeoperatedoutsideofthetemperaturerangeof32°F(0°C)to113°F(45°C).Failuretocomplywiththeseoperatingrequirementsmayvoidtheproductwarranty.

2fantrayslotsThecustomermustorderfantrays,asfantraysarenotincludedwiththeswitch.Thissystemrequirestwosame-directionairflowfantraystofunctionproperly.Thesystemshouldnotbeoperatedwithonlyonefantrayformorethan24hours.Thesystemshouldnotbeoperatedwithoutafantrayformorethantwominutes.Thesystemshouldnotbeoperatedoutsideofthetemperaturerangeof32°F(0°C)to113°F(45°C).Failuretocomplywiththeseoperatingrequirementsmayvoidtheproductwarranty.

Physical characteristicsDimensions

Weight

17.32(w)x18.11(d)x1.72(h)in.(44x46x4.36cm)22.05lb(10kg)shippingweight

17.32(w)x25.98(d)x1.74(h)in.(44x66x4.42cm)35.27lb(16kg)shippingweight

17.32(w)x25.98(d)x1.72(h)in.(44x66x4.36cm)28.66lb(13kg)shippingweight

Memory and processor 512MBflash;Packetbuffersize:16MB,2GBSDRAM

1GBflash;Packetbuffersize:16MB,4GBSDRAM

512MBflash;Packetbuffersize:16MB,2GBSDRAM

Performance10GbpsLatencyThroughputRouting/SwitchingcapacityRoutingtablesizeMACaddresstablesize

<1µs(64-bytepackets)Upto1071Mpps1440Gbps250Kentries(IPv4),64Kentries(IPv6)288Kentries

<1µs(64-bytepackets)Upto1904Mpps2560Gbps250Kentries(IPv4),64Kentries(IPv6)288Kentries

<1µs(64-bytepackets)Upto1071Mpps1440Gbps250Kentries(IPv4),64Kentries(IPv6)288Kentries

EnvironmentOperatingtemperatureOperatingrelativehumidityAcoustic

32°Fto113°F(0°Cto45°C)10%to90%,noncondensingLow-Speed:59.4dB,High-Speed:72.4dB

32°Fto113°F(0°Cto45°C)10%to95%,noncondensingLow-Speed:62.6dB,High-Speed:74.4dB

32°Fto113°F(0°Cto45°C)10%to90%,noncondensingLow-Speed:65dB,High-Speed:78dB

HPE FlexFabric 5940 Switch Series

Specifications

Page 8Data sheet

HPE FlexFabric 5940 48SFP+ 6QSFP+ Switch (JH395A)

HPE FlexFabric 5940 32QSFP+ Switch (JH396A)

HPE FlexFabric 5940 48XGT 6QSFP+ Switch (JH394A)

Electrical characteristicsFrequencyMaximumheatdissipationVoltage

MaximumpowerratingNotes

50/60Hz512BTU/hr(540.19kJ/hr)100–240VAC,rated-40to-60VDC,rated(dependingonpowersupplychosen)150WMaximumpowerratingandmaximumheatdissipationaretheworst-casetheoreticalmaximumnumbersprovidedforplanningtheinfrastructurewithfullyloadedPoE(ifequipped),100%traffic,allportspluggedin,andallmodulespopulated.

50/60Hz1027BTU/hr(1083.54kJ/hr)100–240VAC,rated-40to-60VDC,rated(dependingonpowersupplychosen)301WMaximumpowerratingandmaximumheatdissipationaretheworst-casetheoreticalmaximumnumbersprovidedforplanningtheinfrastructurewithfullyloadedPoE(ifequipped),100%traffic,allportspluggedin,andallmodulespopulated.

50/60Hz912BTU/hr(962.21kJ/hr)100–240VAC,rated-40to-60VDC,rated(dependingonpowersupplychosen)270WMaximumpowerratingandmaximumheatdissipationaretheworst-casetheoreticalmaximumnumbersprovidedforplanningtheinfrastructurewithfullyloadedPoE(ifequipped),100%traffic,allportspluggedin,andallmodulespopulated.

Safety UL60950-1;EN60825-1SafetyofLaserProducts-Part1;EN60825-2SafetyofLaserProducts-Part2;IEC60950-1;CAN/CSA-C22.2No.60950-1;Anatel;ULAR;GOST;EN60950-1/A11;FDA21CFRSubchapterJ;NOM;RoHSCompliance

UL60950-1;EN60825-1SafetyofLaserProducts-Part1;EN60825-2SafetyofLaserProducts-Part2;IEC60950-1;CAN/CSA-C22.2No.60950-1;Anatel;ULAR;GOST;EN60950-1/A11;FDA21CFRSubchapterJ;NOM;RoHSCompliance

UL60950-1;EN60825-1SafetyofLaserProducts-Part1;EN60825-2SafetyofLaserProducts-Part2;IEC60950-1;CAN/CSA-C22.2No.60950-1;Anatel;ULAR;GOST;EN60950-1/A11;FDA21CFRSubchapterJ;NOM;RoHSCompliance

Emissions VCCIClassA;EN55022ClassA;ICES-003ClassA;ANSIC63.4 2003;AS/NZSCISPR22ClassA;EN61000-3-2:2006;EN61000-3-3:1995+A1:2001+A2:2005;EMCDirective2004/108/EC;FCC(CFR47,Part15)ClassA;ANSI/TIA-1057LLDPMediaEndpointDiscovery(LLDP-MED)

VCCIClassA;EN55022ClassA;ICES-003ClassA;ANSIC63.4 2003;AS/NZSCISPR22ClassA;EN61000-3-2:2006;EN61000-3-3:1995+A1:2001+A2:2005;EMCDirective2004/108/EC;FCC(CFR47,Part15)ClassA;ANSI/TIA-1057LLDPMediaEndpointDiscovery(LLDP-MED)

VCCIClassA;EN55022ClassA;ICES-003ClassA;ANSIC63.4 2003;AS/NZSCISPR22ClassA;EN61000-3-2:2006;EN61000-3-3:1995+A1:2001+A2:2005;EMCDirective2004/108/EC;FCC(CFR47,Part15)ClassA;ANSI/TIA-1057LLDPMediaEndpointDiscovery(LLDP-MED)

HPE FlexFabric 5940 Switch Series

Specifications (continued)

Page 9Data sheet

HPE FlexFabric 5940 48SFP+ 6QSFP+ Switch (JH395A)

HPE FlexFabric 5940 32QSFP+ Switch (JH396A)

HPE FlexFabric 5940 48XGT 6QSFP+ Switch (JH394A)

ImmunityGenericENESDRadiatedEFT/BurstSurgeConductedPowerfrequencymagneticfieldVoltagedipsandinterruptionsHarmonicsFlicker

ETSIEN300 386V1.3.3EN55024:1998+A1:2001+A2:2003EN61000-4-2;IEC61000-4-2EN61000-4-3;IEC61000-4-3EN61000-4-4;IEC61000-4-4EN61000-4-5;IEC61000-4-5EN61000-4-6;IEC61000-4-6IEC61000-4-8;EN61000-4-8EN61000-4-11;IEC61000-4-11EN61000-3-2;IEC61000-3-2EN61000-3-3;IEC61000-3-3

ETSIEN300 386V1.3.3EN55024:1998+A1:2001+A2:2003EN61000-4-2;IEC61000-4-2EN61000-4-3;IEC61000-4-3EN61000-4-4;IEC61000-4-4EN61000-4-5;IEC61000-4-5EN61000-4-6;IEC61000-4-6IEC61000-4-8;EN61000-4-8EN61000-4-11;IEC61000-4-11EN61000-3-2;IEC61000-3-2EN61000-3-3;IEC61000-3-3

ETSIEN300 386V1.3.3EN55024:1998+A1:2001+A2:2003EN61000-4-2;IEC61000-4-2EN61000-4-3;IEC61000-4-3EN61000-4-4;IEC61000-4-4EN61000-4-5;IEC61000-4-5EN61000-4-6;IEC61000-4-6IEC61000-4-8;EN61000-4-8EN61000-4-11;IEC61000-4-11EN61000-3-2;IEC61000-3-2EN61000-3-3;IEC61000-3-3

Management IMC—IntelligentManagementCenter;Command-lineinterface;Out-of-bandmanagement;SNMPmanager;Telnet;FTP

IMC—IntelligentManagementCenter;Command-lineinterface;Out-of-bandmanagement;SNMPmanager;Telnet;FTP

IMC—IntelligentManagementCenter;Command-lineinterface;Out-of-bandmanagement;SNMPmanager;Telnet;FTP

Notes Thecustomermustorderapowersupply,asthedevicedoesnotcomewithone.AtleastoneJC680AorJH336Aisrequired.

Thecustomermustorderapowersupply,asthedevicedoesnotcomewithone.AtleastoneJC680AorJH336Aisrequired.

Thecustomermustorderapowersupply,asthedevicedoesnotcomewithone.AtleastoneJC680AorJH336Aisrequired.

Services RefertotheHewlettPackardEnterprisewebsiteathpe.com/networking/servicesfordetailsontheservice-leveldescriptionsandproductnumbers.Fordetailsaboutservicesandresponsetimesinyourarea,pleasecontactyourlocalHewlettPackardEnterprisesalesoffice.

RefertotheHewlettPackardEnterprisewebsiteathpe.com/networking/servicesfordetailsontheservice-leveldescriptionsandproductnumbers.Fordetailsaboutservicesandresponsetimesinyourarea,pleasecontactyourlocalHewlettPackardEnterprisesalesoffice.

RefertotheHewlettPackardEnterprisewebsiteathpe.com/networking/servicesfordetailsontheservice-leveldescriptionsandproductnumbers.Fordetailsaboutservicesandresponsetimesinyourarea,pleasecontactyourlocalHewlettPackardEnterprisesalesoffice.

HPE FlexFabric 5940 Switch Series

Specifications (continued)

Page 10Data sheet

HPE FlexFabric 5940 48SFP+ 6QSFP28 Switch (JH390A) HPE FlexFabric 5940 48XGT 6QSFP28 Switch (JH391A)

I/O ports and slots 48fixed1000/10000SFP+ports6QSFP28 100GbEports

48 1/10GBASE-Tports6QSFP28 100GbEports

Additional ports and slots 1RJ-45and1MiniUSBserialconsoleport1RJ-45and1SFPout-of-bandmanagementport1USB2.0

1RJ-45and1MiniUSBserialconsoleport1RJ-45and1SFP+out-of-bandmanagementport1USB2.0

Power supplies 2powersupplyslots1minimumpowersupplyrequired(orderedseparately)

2powersupplyslots1minimumpowersupplyrequired(orderedseparately)

Fan tray 2fantrayslotsThecustomermustorderfantrays,asfantraysarenotincludedwiththeswitch.Thissystemrequirestwosame-directionairflowfantraystofunctionproperly.Thesystemshouldnotbeoperatedwithonlyonefantrayformorethan24hours.Thesystemshouldnotbeoperatedwithoutafantrayformorethantwominutes.Thesystemshouldnotbeoperatedoutsideofthetemperaturerangeof32°F(0°C)to113°F(45°C).Failuretocomplywiththeseoperatingrequirementsmayvoidtheproductwarranty.

2fantrayslotsThecustomermustorderfantrays,asfantraysarenotincludedwiththeswitch.Thissystemrequirestwosame-directionairflowfantraystofunctionproperly.Thesystemshouldnotbeoperatedwithonlyonefantrayformorethan24hours.Thesystemshouldnotbeoperatedwithoutafantrayformorethantwominutes.Thesystemshouldnotbeoperatedoutsideofthetemperaturerangeof32°F(0°C)to113°F(45°C).Failuretocomplywiththeseoperatingrequirementsmayvoidtheproductwarranty.

Physical characteristicsDimensionsWeight

17.32(w)x18.11(d)x1.72(h)in.(44x46x4.36cm)24.25lb(11kg)shippingweight

17.32(w)x25.98(d)x1.72(h)in.(44x66x4.36cm)28.66lb(13kg)shippingweight

Memory and processor 1GBflash;Packetbuffersize:16MB,4GBSDRAM 1GBflash;Packetbuffersize:16MB,4GBSDRAM

Performance10GbpsLatencyThroughputRouting/SwitchingcapacityRoutingtablesizeMACaddresstablesize

<1µs(64-bytepackets)Upto1607Mpps2160Gbps250Kentries(IPv4),64Kentries(IPv6)288Kentries

<1µs(64-bytepackets)Upto1607Mpps2160Gbps250Kentries(IPv4),64Kentries(IPv6)288Kentries

EnvironmentOperatingtemperatureOperatingrelativehumidityAcoustic

32°Fto113°F(0°Cto45°C)10%to90%,noncondensingLow-Speed:60.1dB,High-Speed:75.9dB

32°Fto113°F(0°Cto45°C)10%to90%,noncondensingLow-Speed:57.4dB,High-Speed:66.1dB

HPE FlexFabric 5940 Switch Series

Specifications (continued)

Page 11Data sheet

HPE FlexFabric 5940 48SFP+ 6QSFP28 Switch (JH390A) HPE FlexFabric 5940 48XGT 6QSFP28 Switch (JH391A)

Electrical characteristicsFrequencyMaximumheatdissipationVoltage

MaximumpowerratingNotes

50/60Hz669BTU/hr(705.83kJ/hr)100–240VAC,rated-40to-60VDC,rated(dependingonpowersupplychosen)196WMaximumpowerratingandmaximumheatdissipationaretheworst-casetheoreticalmaximumnumbersprovidedforplanningtheinfrastructurewithfullyloadedPoE(ifequipped),100%traffic,allportspluggedin,andallmodulespopulated.

50/60Hz1092BTU/hr(1152.12kJ/hr)100–240VAC,rated-40to-60VDC,rated(dependingonpowersupplychosen)320WMaximumpowerratingandmaximumheatdissipationaretheworst-casetheoreticalmaximumnumbersprovidedforplanningtheinfrastructurewithfullyloadedPoE(ifequipped),100%traffic,allportspluggedin,andallmodulespopulated.

Safety UL60950-1;EN60825-1SafetyofLaserProducts-Part1;EN60825-2SafetyofLaserProducts-Part2;IEC60950-1;CAN/CSA-C22.2No.60950-1;Anatel;ULAR;GOST;EN60950-1/A11;FDA21CFRSubchapterJ;NOM;RoHSCompliance

UL60950-1;EN60825-1SafetyofLaserProducts-Part1;EN60825-2SafetyofLaserProducts-Part2;IEC60950-1;CAN/CSA-C22.2No.60950-1;Anatel;ULAR;GOST;EN60950-1/A11;FDA21CFRSubchapterJ;NOM;RoHSCompliance

Emissions VCCIClassA;EN55022ClassA;ICES-003ClassA;ANSIC63.4 2003;AS/NZSCISPR22ClassA;EN61000-3-2:2006;EN61000-3-3:1995+A1:2001+A2:2005;EMCDirective2004/108/EC;FCC(CFR47,Part15)ClassA;ANSI/TIA-1057LLDPMediaEndpointDiscovery(LLDP-MED)

VCCIClassA;EN55022ClassA;ICES-003ClassA;ANSIC63.4 2003;AS/NZSCISPR22ClassA;EN61000-3-2:2006;EN61000-3-3:1995+A1:2001+A2:2005;EMCDirective2004/108/EC;FCC(CFR47,Part15)ClassA;ANSI/TIA-1057LLDPMediaEndpointDiscovery(LLDP-MED)

ImmunityGenericENESDRadiatedEFT/BurstSurgeConductedPowerfrequencymagneticfieldVoltagedipsandinterruptionsHarmonicsFlicker

ETSIEN300 386V1.3.3EN55024:1998+A1:2001+A2:2003EN61000-4-2;IEC61000-4-2EN61000-4-3;IEC61000-4-3EN61000-4-4;IEC61000-4-4EN61000-4-5;IEC61000-4-5EN61000-4-6;IEC61000-4-6IEC61000-4-8;EN61000-4-8EN61000-4-11;IEC61000-4-11EN61000-3-2;IEC61000-3-2EN61000-3-3;IEC61000-3-3

ETSIEN300 386V1.3.3EN55024:1998+A1:2001+A2:2003EN61000-4-2;IEC61000-4-2EN61000-4-3;IEC61000-4-3EN61000-4-4;IEC61000-4-4EN61000-4-5;IEC61000-4-5EN61000-4-6;IEC61000-4-6IEC61000-4-8;EN61000-4-8EN61000-4-11;IEC61000-4-11EN61000-3-2;IEC61000-3-2EN61000-3-3;IEC61000-3-3

Management IMC—IntelligentManagementCenter;Command-lineinterface;Out-of-bandmanagement;SNMPmanager;Telnet;FTP

IMC—IntelligentManagementCenter;Command-lineinterface;Out-of-bandmanagement;SNMPmanager;Telnet;FTP

Notes Thecustomermustorderapowersupply,asthedevicedoesnotcomewithone.AtleastoneJC680AorJH336Aisrequired.

Thecustomermustorderapowersupply,asthedevicedoesnotcomewithone.AtleastoneJC680AorJH336Aisrequired.

Services RefertotheHewlettPackardEnterprisewebsiteathpe.com/networking/servicesfordetailsontheservice-leveldescriptionsandproductnumbers.Fordetailsaboutservicesandresponsetimesinyourarea,pleasecontactyourlocalHewlettPackardEnterprisesalesoffice.

RefertotheHewlettPackardEnterprisewebsiteathpe.com/networking/servicesfordetailsontheservice-leveldescriptionsandproductnumbers.Fordetailsaboutservicesandresponsetimesinyourarea,pleasecontactyourlocalHewlettPackardEnterprisesalesoffice.

HPE FlexFabric 5940 Switch Series

Specifications (continued)

Page 12Data sheet

HPE FlexFabric 5940 2-slot Switch (JH397A) HPE FlexFabric 5940 4-slot Switch (JH398A)

I/O ports and slots 2moduleslots2QSFP+40GbEportsSupportsamaximumof18 40GbEportsor48 1/10GBASE-Tportsor48SFP+portsor48Convergedports,oracombination

4moduleslotsSupportsamaximumof32 40GbEportsor96 1/10GBASE-Tportsor96SFP+portsor96Convergedports,oracombination

Additional ports and slots 1RJ-45and1MiniUSB2.0serialconsoleport1RJ-45out-of-bandmanagementport1USB2.0

1RJ-45and1MiniUSB2.0serialconsoleport1RJ-45out-of-bandmanagementport1USB2.0

Power supplies 2powersupplyslots1minimumpowersupplyrequired(orderedseparately)

4powersupplyslots2minimumpowersuppliesrequired(orderedseparately)

Fan tray 2fantrayslotsThecustomermustorderfantrays,asfantraysarenotincludedwiththeswitch.Thissystemrequirestwosame-directionairflowfantraystofunctionproperly.Thesystemshouldnotbeoperatedwithonlyonefantrayformorethan24hours.Thesystemshouldnotbeoperatedwithoutafantrayformorethantwominutes.Thesystemshouldnotbeoperatedoutsideofthetemperaturerangeof32°F(0°C)to113°F(45°C).Failuretocomplywiththeseoperatingrequirementsmayvoidtheproductwarranty.

2fantrayslotsThecustomermustorderfantrays,asfantraysarenotincludedwiththeswitch.Thissystemrequirestwosame-directionairflowfantraystofunctionproperly.Thesystemshouldnotbeoperatedwithonlyonefantrayformorethan24hours.Thesystemshouldnotbeoperatedwithoutafantrayformorethantwominutes.Thesystemshouldnotbeoperatedoutsideofthetemperaturerangeof32°F(0°C)to113°F(45°C).Failuretocomplywiththeseoperatingrequirementsmayvoidtheproductwarranty.

Physical characteristicsDimensions

WeightFullconfigurationweight

17.32(w)x25.98(d)x1.74(h)in.(44.00x66.0x4.42cm)(1Uheight)39.68lb(18kg)shippingweight35.27lb(16kg)

17.32(w)x25.98(d)x3.47(h)in.(44.00x66.0x8.81cm)(2Uheight)66.14lb(30kg)shippingweight59.52lb(27kg)

Memory and processor 1GBflash;Packetbuffersize:16MB,4GBSDRAM 1GBflash;Packetbuffersize:16MB,4GBSDRAM

Performance10GbpsLatencyThroughputRouting/SwitchingcapacityRoutingtablesizeMACaddresstablesize

<1µs(64-bytepackets)Upto1071Mpps1440Gbps250Kentries(IPv4),64Kentries(IPv6)288Kentries

<1µs(64-bytepackets)Upto1904Mpps2560Gbps250Kentries(IPv4),64Kentries(IPv6)288Kentries

ReliabilityMTBF(years)MTTR(hours)

47.21

35.81

EnvironmentOperatingtemperatureOperatingrelativehumidityAcoustic

32°Fto113°F(0°Cto45°C)10%to90%,noncondensingLow-Speed:69.8dB,High-Speed:82.2dB

32°Fto113°F(0°Cto45°C)10%to90%,noncondensingLow-Speed:61.3dB,High-Speed:78.4dB

HPE FlexFabric 5940 Switch Series

Specifications (continued)

Page 13Data sheet

HPE FlexFabric 5940 2-slot Switch (JH397A) HPE FlexFabric 5940 4-slot Switch (JH398A)

Electrical characteristicsFrequencyMaximumheatdissipationVoltage

MaximumpowerratingIdlepowerNotes

50/60Hz2921BTU/hr100–240VAC,rated-40to-60VDC,rated(dependingonpowersupplychosen)450W105WIdlepoweristheactualpowerconsumptionofthedevicewithnoportsconnected.Maximumpowerratingandmaximumheatdissipationaretheworst-casetheoreticalmaximumnumbersprovidedforplanningtheinfrastructurewithfullyloadedPoE(ifequipped),100%traffic,allportspluggedin,andallmodulespopulated.

50/60Hz1535BTU/hr100–240VAC,rated-40to-60VDC,rated(dependingonpowersupplychosen)856W139WIdlepoweristheactualpowerconsumptionofthedevicewithnoportsconnected.Maximumpowerratingandmaximumheatdissipationaretheworst-casetheoreticalmaximumnumbersprovidedforplanningtheinfrastructurewithfullyloadedPoE(ifequipped),100%traffic,allportspluggedin,andallmodulespopulated.

Safety UL60950-1;EN60825-1SafetyofLaserProducts-Part1;EN60825-2SafetyofLaserProducts-Part2;IEC60950-1;CAN/CSA-C22.2No.60950-1;Anatel;ULAR;GOST;EN60950-1/A11;FDA21CFRSubchapterJ;NOM;RoHSCompliance

UL60950-1;EN60825-1SafetyofLaserProducts-Part1;EN60825-2SafetyofLaserProducts-Part2;IEC60950-1;CAN/CSA-C22.2No.60950-1;Anatel;ULAR;GOST;EN60950-1/A11;FDA21CFRSubchapterJ;NOM;RoHSCompliance

Emissions VCCIClassA;EN55022ClassA;ICES-003ClassA;ANSIC63.4 2003;AS/NZSCISPR22ClassA;EN61000-3-2:2006;EN61000-3-3:1995+A1:2001+A2:2005;EMCDirective2004/108/EC;FCC(CFR47,Part15)ClassA;ANSI/TIA-1057LLDPMediaEndpointDiscovery(LLDP-MED)

VCCIClassA;EN55022ClassA;ICES-003ClassA;ANSIC63.4 2003;AS/NZSCISPR22ClassA;EN61000-3-2:2006;EN61000-3-3:1995+A1:2001+A2:2005;EMCDirective2004/108/EC;FCC(CFR47,Part15)ClassA;ANSI/TIA-1057LLDPMediaEndpointDiscovery(LLDP-MED)

ImmunityGenericENESDRadiatedEFT/BurstSurgeConductedPowerfrequencymagneticfieldVoltagedipsandinterruptionsHarmonicsFlicker

ETSIEN300 386V1.3.3EN55024:1998+A1:2001+A2:2003EN61000-4-2;IEC61000-4-2EN61000-4-3;IEC61000-4-3EN61000-4-4;IEC61000-4-4EN61000-4-5;IEC61000-4-5EN61000-4-6;IEC61000-4-6IEC61000-4-8;EN61000-4-8EN61000-4-11;IEC61000-4-11EN61000-3-2,IEC61000-3-2EN61000-3-3,IEC61000-3-3

ETSIEN300 386V1.3.3EN55024:1998+A1:2001+A2:2003EN61000-4-2;IEC61000-4-2EN61000-4-3;IEC61000-4-3EN61000-4-4;IEC61000-4-4EN61000-4-5;IEC61000-4-5EN61000-4-6;IEC61000-4-6IEC61000-4-8;EN61000-4-8EN61000-4-11;IEC61000-4-11EN61000-3-2,IEC61000-3-2EN61000-3-3,IEC61000-3-3

Management IMC—IntelligentManagementCenter;Command-lineinterface;Out-of-bandmanagement;SNMPmanager;Telnet;FTP

IMC—IntelligentManagementCenter;Command-lineinterface;Out-of-bandmanagement;SNMPmanager;Telnet;FTP

Notes Thecustomermustorderapowersupply,asthedevicedoesnotcomewithone.AtleastoneJC680AorJC336Aisrequired.

Services RefertotheHewlettPackardEnterprisewebsiteat hpe.com/networking/servicesfordetailsontheservice-leveldescriptionsandproductnumbers.Fordetailsaboutservicesandresponsetimesinyourarea,pleasecontactyourlocalHewlettPackardEnterprisesalesoffice.

RefertotheHewlettPackardEnterprisewebsiteathpe.com/networking/servicesfordetailsontheservice-leveldescriptionsandproductnumbers.Fordetailsaboutservicesandresponsetimesinyourarea,pleasecontactyourlocalHewlettPackardEnterprisesalesoffice.

HPE FlexFabric 5940 Switch Series

Specifications (continued)

Page 14Data sheet

Standards and protocols(Appliestoallproductsinseries)

BGP RFC1163BorderGatewayProtocol(BGP)RFC1771BGPv4RFC1997BGPCommunitiesAttributeRFC2918RouteRefreshCapability

RFC3392CapabilitiesAdvertisementwithBGP-4RFC4271ABorderGatewayProtocol4(BGP-4)RFC4360BGPExtendedCommunitiesAttribute

RFC4456BGPRouteReflection:AnAlternativetoFullMeshInternalBGP(IBGP)RFC4760MultiprotocolExtensionsforBGP-4RFC7432BGPMPLS-BasedEthernetVPN

Device management RFC1157SNMPv1/v2cRFC1305NTPv3RFC1591DNS(client)RFC1902(SNMPv2)

RFC1908(SNMPv1/2Coexistence)RFC2573(SNMPv3Applications)RFC2576(CoexistencebetweenSNMPv1,v2,andv3)RFC2819RMON

MultipleConfigurationFilesMultipleSoftwareImagesSSHv1/SSHv2SecureShellTACACS/TACACS+

General protocols IEEE802.1adQ-in-QIEEE802.1AX-2008LinkAggregationIEEE802.1DMACBridgesIEEE802.1pPriorityIEEE802.1QVLANsIEEE802.1sMultipleSpanningTreesIEEE802.1wRapidReconfigurationofSpanningTreeIEEE802.3adLinkAggregationControlProtocol(LACP)IEEE802.3ae10-GigabitEthernetIEEE802.3agEthernetOAMIEEE802.3ahEthernetinFirstMileoverPointtoPointFiber—EFMFIEEE802.3xFlowControlRFC768UDPRFC783TFTPProtocol(revision2)RFC791IPRFC792ICMPRFC793TCPRFC826ARPRFC854TELNETRFC856TELNETRFC868TimeProtocolRFC896CongestionControlinIP/TCPInternetworksRFC950InternetStandardSubnettingProcedureRFC1027ProxyARPRFC1058RIPv1RFC1091TelnetTerminal-TypeOptionRFC1141IncrementalupdatingoftheInternetchecksumRFC1142OSIIS-ISIntra-domainRoutingProtocolRFC1191PathMTUdiscovery

RFC1213ManagementInformationBaseforNetworkManagementofTCP/IP-basedInternetsRFC1253(OSPFv2)RFC1531DynamicHostConfigurationProtocolRFC1533DHCPOptionsandBOOTPVendorExtensionsRFC1534DHCP/BOOTPInteroperationRFC1541DHCPRFC1542ClarificationsandExtensionsfortheBootstrapProtocolRFC1591DNS(clientonly)RFC1624IncrementalInternetChecksumRFC1723RIPv2RFC1812IPv4RoutingRFC2030SimpleNetworkTimeProtocol(SNTP)v4RFC2131DHCPRFC2236IGMPSnoopingRFC2338VRRPRFC2453RIPv2RFC2581TCPCongestionControlRFC2644DirectedBroadcastControlRFC2767DualStacksIPv4&IPv6RFC2865RemoteAuthenticationDialInUserService(RADIUS)RFC2868RADIUSAttributesforTunnelProtocolSupportRFC2890KeyandSequenceNumberExtensionstoGRERFC3046DHCPRelayAgentInformationOptionRFC3411anArchitectureforDescribingSimpleNetworkManagementProtocol(SNMP)ManagementFrameworksRFC3412MessageProcessingandDispatchingfortheSimpleNetworkManagementProtocol(SNMP)

RFC3413SimpleNetworkManagementProtocol(SNMP)ApplicationsRFC3416ProtocolOperationsforSNMPRFC3417TransportMappingsfortheSimpleNetworkManagementProtocol(SNMP)RFC3418ManagementInformationBase(MIB)fortheSimpleNetworkManagementProtocol(SNMP)RFC3768VirtualRouterRedundancyProtocol(VRRP)RFC4250TheSecureShell(SSH)ProtocolAssignedNumbersRFC4251TheSecureShell(SSH)ProtocolArchitectureRFC4252TheSecureShell(SSH)AuthenticationProtocolRFC4253TheSecureShell(SSH)TransportLayerProtocolRFC4254TheSecureShell(SSH)ConnectionProtocolRFC4292IPForwardingTableMIBRFC4293ManagementInformationBasefortheInternetProtocol(IP)RFC4364BGP/MPLSIPVirtualPrivateNetworks(VPNs)RFC4419Diffie-HellmanGroupExchangefortheSecureShell(SSH)TransportLayerProtocolRFC4594ConfigurationGuidelinesforDiffServServiceClassesRFC4601ProtocolIndependentMulticast-SparseMode(PIM-SM):ProtocolSpecification(revised)RFC4604UsingInternetGroupManagementProtocolVersion3(IGMPv3)andMulticastListenerDiscoveryProtocolVersion2(MLDv2)forSource-SpecificMulticastRFC4607Source-SpecificMulticastforIPRFC4941PrivacyExtensionsforStatelessAddressAuto-configurationinIPv6RFC5340OSPFforIPv6RFC5905NetworkTimeProtocolVersion4:ProtocolandAlgorithmsSpecificationRFC2929DNSIANAConsiderations

Page 15Data sheet

Standards and protocols(Appliestoallproductsinseries)(continued)

IPv6 RFC2080RIPngforIPv6RFC2460IPv6SpecificationRFC2461IPv6NeighborDiscoveryRFC2462IPv6StatelessAddressAuto-configurationRFC2463ICMPv6RFC2464TransmissionofIPv6overEthernetNetworksRFC2473GenericPacketTunnelinginIPv6RFC2545UseofMP-BGP-4forIPv6

RFC2563ICMPv6RFC2711IPv6RouterAlertOptionRFC2740OSPFv3forIPv6RFC2767DualStackHostsusingBISRFC3315DHCPv6(clientandrelay)RFC3484DefaultAddressSelectionforIPv6RFC3810MulticastListenerDiscoveryVersion2(MLDv2)forIPv6

RFC4213BasicTransitionMechanismsforIPv6HostsandRoutersRFC4291IPVersion6AddressingArchitectureRFC4443ICMPv6RFC4552Authentication/ConfidentialityforOSPFv3RFC4862IPv6StatelessAddressAuto-configurationRFC5095DeprecationofType0RoutingHeadersinIPv6

MIBs RFC1213MIBIIRFC1907SNMPv2MIBRFC2571SNMPFrameworkMIBRFC2572SNMP-MPDMIB

RFC2573SNMP-NotificationMIBRFC2573SNMP-TargetMIBRFC2574SNMPUSMMIBRFC2737EntityMIB(version2)

RFC3414SNMP-User-based-SMMIBRFC3415SNMP-View-based-ACMMIBLLDP-EXT-DOT1-MIBLLDP-EXT-DOT3-MIBLLDP-MIB

Network management RFC2580ConformanceStatementsforSMIv2 RFC3164BSDsyslogProtocol

OSPF RFC1587OSPFNSSARFC2328OSPFv2RFC3101OSPFNSSA

RFC3137OSPFStubRouterAdvertisementRFC3623GracefulOSPFRestartRFC4577OSPFastheProvider/CustomerEdgeProtocolforBGP/MPLSIPVirtualPrivateNetworks(VPNs)

RFC4811OSPFOut-of-BandLSDBResynchronizationRFC4812OSPFRestartSignalingRFC4813OSPFLink-LocalSignaling

QoS/CoS IEEE802.1p(CoS)RFC2475DiffServArchitecture

RFC2597DiffServAssuredForwarding(AF) RFC3247SupplementalInformationfortheNewDefinitionoftheEFPHB(ExpeditedForwardingPer-HopBehavior)RFC3260NewTerminologyandClarificationsforDiffServ

Security RFC1321TheMD5Message-DigestAlgorithmRFC2818HTTPOverTLS

RFC6192PartialSupport—ProtectingtheRouterControlPlane

Accesscontrollists(ACLs)SSHv2SecureShell

Page 16Data sheet

HPE FlexFabric 5940 Switch Series accessories

HPE FlexFabric 5940 48SFP+ 6QSFP+ Switch (JH395A)HPEX120 1GSFPRJ45TTransceiver(JD089B)

HPEX120 1GSFPLCSXTransceiver(JD118B)

HPEX120 1GSFPLCLXTransceiver(JD119B)

HPEX125 1GSFPLCLH40 1310nmTransceiver(JD061A)

HPEX120 1GSFPLCLH40 1550nmTransceiver(JD062A)

HPEX125 1GSFPLCLH80Transceiver(JD063B)

HPEX130 10GSFP+LCSRTransceiver(JD092B)

HPEX130 10GSFP+LCLRTransceiver(JD094B)

HPEX240 10GSFP+SFP+3mDACable(JD097C)

HPEX240SFP+SFP+5mDACCable(JG081C)

HPEX240 10GSFP+SFP+0.65mDACable(JD095C)

HPEX240 10GSFP+SFP+1.2mDACable(JD096C)

HPEX2A0 10GSFP+toSFP+7mActiveOpticalCable(JL290A)

HPEX2A0 10GSFP+toSFP+10mActiveOpticalCable(JL291A)

HPEX2A0 10GSFP+toSFP+20mActiveOpticalCable(JL292A)

HPEX140 40GQSFP+LCLR4SM10km1310nmTransceiver(JG661A)

HPEX140 40GQSFP+MPOMM850nmCSR4 300mTransceiver(JG709A)

HPEX140 40GQSFP+MPOSR4Transceiver(JG325B)

HPEX140 40GQSFP+LCBiDi100mMMTransceiver(JL251A)

HPEX140 40GQSFP+LCLR4L2kmSMTransceiver(JL286A)

HPEX140 40GQSFP+LCER4 40kmSMTransceiver(JL306A)

HPEX240 40GQSFP+QSFP+1mDACCable(JG326A)

HPEX240 40GQSFP+QSFP+3mDACCable(JG327A)

HPEX240 40GQSFP+QSFP+5mDACCable(JG328A)

HPEX240QSFP+4x10GSFP+1mDACCable(JG329A)

HPEX240QSFP+4x10GSFP+3mDACCable(JG330A)

HPEX240QSFP+4x10GSFP+5mDACCable(JG331A)

HPEX2A0 40GQSFP+toQSFP+7mActiveOpticalCable(JL287A)

HPEX2A0 40GQSFP+toQSFP+10mActiveOpticalCable(JL288A)

HPEX2A0 40GQSFP+toQSFP+20mActiveOpticalCable(JL289A)

HPE58x0AFBack(PowerSide)toFront(PortSide)Airflow300WACPowerSupply(JG900A)

HPE58x0AFBack(PowerSide)toFront(PortSide)Airflow300WDCPowerSupply(JG901A)

Page 17Data sheet

HPE58x0AF650WACPowerSupply(JC680A)

HPEFlexFabricSwitch650W48VHotPlugNEBS-compliantDCPowerSupply

HPE58x0AFBack(powerside)toFront(portside)AirflowFanTray(JC682A)

HPE58x0AFFront(portside)toBack(powerside)AirflowFanTray(JC683A)

HPEX711Front(portside)toBack(powerside)AirflowHighVolumeFanTray(JG552A)

HPEX712Back(powerside)toFront(portside)AirflowHighVolumeFanTray(JG553A)

HPE FlexFabric 5940 32QSFP+ Switch (JH396A)HPEX140 40GQSFP+LCLR4SM10km1310nmTransceiver(JG661A)

HPEX140 40GQSFP+MPOMM850nmCSR4 300mTransceiver(JG709A)

HPEX140 40GQSFP+MPOSR4Transceiver(JG325B)

HPEX140 40GQSFP+LCBiDi100mMMTransceiver(JL251A)

HPEX140 40GQSFP+LCLR4L2kmSMTransceiver(JL286A)

HPEX140 40GQSFP+LCER4 40kmSMTransceiver(JL306A)

HPEX240 40GQSFP+QSFP+1mDACCable(JG326A)

HPEX240 40GQSFP+QSFP+3mDACCable(JG327A)

HPEX240 40GQSFP+QSFP+5mDACCable(JG328A)

HPEX240QSFP+4x10GSFP+1mDACCable(JG329A)

HPEX240QSFP+4x10GSFP+3mDACCable(JG330A)

HPEX240QSFP+4x10GSFP+5mDACCable(JG331A)

HPEX2A0 40GQSFP+toQSFP+7mActiveOpticalCable(JL287A)

HPEX2A0 40GQSFP+toQSFP+10mActiveOpticalCable(JL288A)

HPEX2A0 40GQSFP+toQSFP+20mActiveOpticalCable(JL289A)

HPE58x0AF650WACPowerSupply(JC680A)

HPEFlexFabricSwitch650W48VHotPlugNEBS-compliantDCPowerSupply

HPEX711Front(portside)toBack(powerside)AirflowHighVolumeFanTray(JG552A)

HPEX712Back(powerside)toFront(portside)AirflowHighVolumeFanTray(JG553A)

HPE FlexFabric 5940 48XGT 6QSFP+ Switch (JH394A)HPEX140 40GQSFP+LCLR4SM10km1310nmTransceiver(JG661A)

HPEX140 40GQSFP+MPOMM850nmCSR4 300mTransceiver(JG709A)

HPEX140 40GQSFP+MPOSR4Transceiver(JG325B)

HPEX140 40GQSFP+LCBiDi100mMMTransceiver(JL251A)

HPEX140 40GQSFP+LCLR4L2kmSMTransceiver(JL286A)

HPEX140 40GQSFP+LCER4 40kmSMTransceiver(JL306A)

HPEX240 40GQSFP+QSFP+1mDACCable(JG326A)

Page 18Data sheet

HPEX240 40GQSFP+QSFP+3mDACCable(JG327A)

HPEX240 40GQSFP+QSFP+5mDACCable(JG328A)

HPEX240QSFP+4x10GSFP+1mDACCable(JG329A)

HPEX240QSFP+4x10GSFP+3mDACCable(JG330A)

HPEX240QSFP+4x10GSFP+5mDACCable(JG331A)

HPEX2A0 40GQSFP+toQSFP+7mActiveOpticalCable(JL287A)

HPEX2A0 40GQSFP+toQSFP+10mActiveOpticalCable(JL288A)

HPEX2A0 40GQSFP+toQSFP+20mActiveOpticalCable(JL289A)

HPE58x0AF650WACPowerSupply(JC680A)

HPEFlexFabricSwitch650W48VHotPlugNEBS-compliantDCPowerSupply

HPEX711Front(portside)toBack(powerside)AirflowHighVolumeFanTray(JG552A)

HPEX712Back(powerside)toFront(portside)AirflowHighVolumeFanTray(JG553A)

HPE FlexFabric 5940 48SFP+ 6QSFP28 Switch (JH390A)HPEX120 1GSFPRJ45TTransceiver(JD089B)

HPEX120 1GSFPLCSXTransceiver(JD118B)

HPEX120 1GSFPLCLXTransceiver(JD119B)

HPEX125 1GSFPLCLH40 1310nmTransceiver(JD061A)

HPEX120 1GSFPLCLH40 1550nmTransceiver(JD062A)

HPEX125 1GSFPLCLH80Transceiver(JD063B)

HPEX130 10GSFP+LCSRTransceiver(JD092B)

HPEX130 10GSFP+LCLRTransceiver(JD094B)

HPEX240 10GSFP+SFP+3mDACable(JD097C)

HPEX240SFP+SFP+5mDACCable(JG081C)

HPEX240 10GSFP+SFP+0.65mDACable(JD095C)

HPEX240 10GSFP+SFP+1.2mDACable(JD096C)

HPEX2A0 10GSFP+toSFP+7mActiveOpticalCable(JL290A)

HPEX2A0 10GSFP+toSFP+10mActiveOpticalCable(JL291A)

HPEX2A0 10GSFP+toSFP+20mActiveOpticalCable(JL292A)

HPEX140 40GQSFP+LCLR4SM10km1310nmTransceiver(JG661A)

HPEX140 40GQSFP+MPOMM850nmCSR4 300mTransceiver(JG709A)

HPEX140 40GQSFP+MPOSR4Transceiver(JG325B)

HPEX140 40GQSFP+LCBiDi100mMMTransceiver(JL251A)

HPEX140 40GQSFP+LCLR4L2kmSMTransceiver(JL286A)

Page 19Data sheet

HPEX140 40GQSFP+LCER4 40kmSMTransceiver(JL306A)

HPEX240 40GQSFP+QSFP+1mDACCable(JG326A)

HPEX240 40GQSFP+QSFP+3mDACCable(JG327A)

HPEX240 40GQSFP+QSFP+5mDACCable(JG328A)

HPEX150 100GQSFP28MPOSR4 100mMMTransceiver(JL274A)

HPEX150 100GQSFP28LCLR4 10kmSMTransceiver(JL275A)

HPEX150 100GQSFP28LCSWDM4100mMMTransceiver(JH419A)

HPEX150 100GQSFP28MPOPSM4500mSMTransceiver(JH420A)

HPEX150 100GQSFP28CWDM4 2kmSMTransceiver(JH673A)

HPEX240 100GQSFP28toQSFP28 1mDirectAttachCopperCable(JL271A)

HPEX240 100GQSFP28 3mDACCable(JL272A)

HPEX240 100GQSFP28toQSFP28 5mDirectAttachCopperCable(JL273A)

HPE58x0AFBack(PowerSide)toFront(PortSide)Airflow300WACPowerSupply(JG900A)

HPE58x0AFBack(PowerSide)toFront(PortSide)Airflow300WDCPowerSupply(JG901A)

HPE58x0AF650WACPowerSupply(JC680A)

HPEFlexFabricSwitch650W48VHotPlugNEBS-compliantDCPowerSupply

HPE58x0AFBack(powerside)toFront(portside)AirflowFanTray(JC682A)

HPE58x0AFFront(portside)toBack(powerside)AirflowFanTray(JC683A)

HPEX711Front(portside)toBack(powerside)AirflowHighVolumeFanTray(JG552A)

HPEX712Back(powerside)toFront(portside)AirflowHighVolumeFanTray(JG553A)

HPE FlexFabric 5940 48XGT 6QSFP28 Switch (JH391A)HPEX140 40GQSFP+LCLR4SM10km1310nmTransceiver(JG661A)

HPEX140 40GQSFP+MPOMM850nmCSR4 300mTransceiver(JG709A)

HPEX140 40GQSFP+MPOSR4Transceiver(JG325B)

HPEX140 40GQSFP+LCBiDi100mMMTransceiver(JL251A)

HPEX140 40GQSFP+LCLR4L2kmSMTransceiver(JL286A)

HPEX140 40GQSFP+LCER4 40kmSMTransceiver(JL306A)

HPEX240 40GQSFP+QSFP+1mDACCable(JG326A)

HPEX240 40GQSFP+QSFP+3mDACCable(JG327A)

HPEX240 40GQSFP+QSFP+5mDACCable(JG328A)

Page 20Data sheet

HPEX150 100GQSFP28MPOSR4 100mMMTransceiver(JL274A)

HPEX150 100GQSFP28LCLR4 10kmSMTransceiver(JL275A)

HPEX150 100GQSFP28LCSWDM4 100mMMTransceiver(JH419A)

HPEX150 100GQSFP28MPOPSM4 500mSMTransceiver(JH420A)

HPEX150 100GQSFP28CWDM4 2kmSMTransceiver(JH673A)

HPEX240 100GQSFP28toQSFP28 1mDirectAttachCopperCable(JL271A)

HPEX240 100GQSFP28 3mDACCable(JL272A)

HPEX240 100GQSFP28toQSFP28 5mDirectAttachCopperCable(JL273A)

HPE58x0AF650WACPowerSupply(JC680A)

HPEFlexFabricSwitch650W48VHotPlugNEBS-compliantDCPowerSupply

HPEX711Front(portside)toBack(powerside)AirflowHighVolumeFanTray(JG552A)

HPEX712Back(powerside)toFront(portside)AirflowHighVolumeFanTray(JG553A)

HPE FlexFabric 5940 2-slot Switch (JH397A)HPEX240 10GSFP+SFP+5mDACCable(JG081C)

HPEX240 10GSFP+SFP+0.65mDACCable(JD095C)

HPEX130 10GSFP+LCLH80kmTransceiver—onlyonportswithPHY(JG915A)

HPEFlexFabricSwitch650W48VHotPlugNEBS-compliantDCPowerSupply

HPE5930 24-portSFP+and2-portQSFP+Module(JH180A)

HPE5930 24-portSFP+and2-portQSFP+withMACsecModule(JH181A)

HPE5930 24-port10GBASE-Tand2-portQSFP+withMACsecModule(JH182A)

HPE5930 8-portQSFP+Module(JH183A)

HPE5930 24-portConvergedPortand2-portQSFP+Module(JH184A)

HPE5940 2-portQSFP+and2-portQSFP28Module(JH409A)

HPEFlexFabric5950 8-portQSFP28MACsecModule(JH957A)

HPEX125 1GSFPLCLH40 1310nmTransceiver(JD061A)

HPEX120 1GSFPLCLH40 1550nmTransceiver(JD062A)

HPEX125 1GSFPLCLH70Transceiver(JD063B)

HPEX120 1GSFPRJ45TTransceiver(JD089B)

HPEX120 1GSFPLCSXTransceiver(JD118B)

HPEX120 1GSFPLCLXTransceiver(JD119B)

HPEX240 10GSFP+SFP+7mDirectAttachCopperCable(JC784C)

Page 21Data sheet

HPEX130 10GSFP+LCSRTransceiver(JD092B)

HPEX130 10GSFP+LCLRTransceiver(JD094B)

HPEX240 10GSFP+toSFP+1.2mDirectAttachCopperCable(JD096C)

HPEX240 10GSFP+toSFP+3mDirectAttachCopperCable(JD097C)

HPEX130 10GSFP+LCER40kmTransceiver(JG234A)

HPEX130 10GSFP+LCLH80TunableTransceiver(JL250A)

HPEX2A0 10GSFP+toSFP+7mActiveOpticalCable(JL290A)

HPEX2A0 10GSFP+toSFP+10mActiveOpticalCable(JL291A)

HPEX2A0 10GSFP+toSFP+20mActiveOpticalCable(JL292A)

HPEX140 40GQSFP+MPOSR4Transceiver(JG325B)

HPEX240 40GQSFP+toQSFP+1mDirectAttachCopperCable(JG326A)

HPEX240 40GQSFP+toQSFP+3mDirectAttachCopperCable(JG327A)

HPEX240 40GQSFP+toQSFP+5mDirectAttachCopperCable(JG328A)

HPEX240 40GQSFP+to4x10GSFP+1mDirectAttachCopperSplitterCable(JG329A)

HPEX240 40GQSFP+to4x10GSFP+3mDirectAttachCopperSplitterCable(JG330A)

HPEX240 40GQSFP+to4x10GSFP+5mDirectAttachCopperSplitterCable(JG331A)

HPEX140 40GQSFP+LCLR4SM10km1310nmTransceiver(JG661A)

HPEX140 40GQSFP+MPOMM850nmCSR4 300mTransceiver(JG709A)

HPEX140 40GQSFP+LCBiDi100mMMTransceiver(JL251A)

HPEX140 40GQSFP+LCLR4L2kmSMTransceiver(JL286A)

HPEX2A0 40GQSFP+toQSFP+7mActiveOpticalCable(JL287A)

HPEX2A0 40GQSFP+toQSFP+10mActiveOpticalCable(JL288A)

HPEX2A0 40GQSFP+toQSFP+20mActiveOpticalCable(JL289A)

HPEX240 100GQSFP28toQSFP28 5mDirectAttachCopperCable(JL273A)

HPEX240 100GQSFP28toQSFP28 1mDirectAttachCopperCable(JL271A)

HPEX240 100GQSFP28toQSFP28 3mDirectAttachCopperCable(JL272A)

HPEX150 100GQSFP28MPOSR4 100mMMTransceiver(JL274A)

HPEX150 100GQSFP28LCLR4 10kmSMTransceiver(JL275A)

HPEX150 100GQSFP28LCSWDM4100mMMTransceiver(JH419A)

HPEX150 100GQSFP28CWDM4 2kmSMTransceiver(JH673A)

HPE58x0AF650WACPowerSupply(JC680A)

HPEX711Front(portside)toBack(powerside)AirflowHighVolumeFanTray(JG552A)

HPEX712Back(powerside)toFront(portside)AirflowHighVolumeFanTray(JG553A)

Page 22Data sheet

HPE FlexFabric 5940 4-slot Switch (JH398A)HPEX240 10GSFP+SFP+5mDACCable(JG081C)

HPEX240 10GSFP+SFP+0.65mDACCable(JD095C)

HPEX130 10GSFP+LCLH80kmTransceiver—onlyonportswithPHY(JG915A)

HPEFlexFabricSwitch650W48VHotPlugNEBS-compliantDCPowerSupply

HPE5930 24-portSFP+and2-portQSFP+Module(JH180A)

HPE5930 24-portSFP+and2-portQSFP+withMACsecModule(JH181A)

HPE5940 2-portQSFP+and2-portQSFP28Module(JH409A)

HPE5930 24-port10GBASE-Tand2-portQSFP+withMACsecModule(JH182A)

HPE5930 8-portQSFP+Module(JH183A)

HPE5930 24-portConvergedPortand2-portQSFP+Module(JH184A)

HPEFlexFabric5950 8-portQSFP28MACsecModule(JH957A)

HPEX125 1GSFPLCLH40 1310nmTransceiver(JD061A)

HPEX120 1GSFPLCLH40 1550nmTransceiver(JD062A)

HPEX125 1GSFPLCLH70Transceiver(JD063B)

HPEX120 1GSFPRJ45TTransceiver(JD089B)

HPEX120 1GSFPLCSXTransceiver(JD118B)

HPEX120 1GSFPLCLXTransceiver(JD119B)

HPEX240 10GSFP+SFP+7mDirectAttachCopperCable(JC784C)

HPEX130 10GSFP+LCSRTransceiver(JD092B)

HPEX130 10GSFP+LCLRTransceiver(JD094B)

HPEX240 10GSFP+toSFP+1.2mDirectAttachCopperCable(JD096C)

HPEX240 10GSFP+toSFP+3mDirectAttachCopperCable(JD097C)

HPEX130 10GSFP+LCER40kmTransceiver(JG234A)

HPEX130 10GSFP+LCLH80TunableTransceiver(JL250A)

HPEX2A0 10GSFP+toSFP+7mActiveOpticalCable(JL290A)

HPEX2A0 10GSFP+toSFP+10mActiveOpticalCable(JL291A)

HPEX2A0 10GSFP+toSFP+20mActiveOpticalCable(JL292A)

HPEX140 40GQSFP+MPOSR4Transceiver(JG325B)

HPEX240 40GQSFP+toQSFP+1mDirectAttachCopperCable(JG326A)

HPEX240 40GQSFP+toQSFP+3mDirectAttachCopperCable(JG327A)

HPEX240 40GQSFP+toQSFP+5mDirectAttachCopperCable(JG328A)

HPEX240 40GQSFP+to4x10GSFP+1mDirectAttachCopperSplitterCable(JG329A)

HPEX240 40GQSFP+to4x10GSFP+3mDirectAttachCopperSplitterCable(JG330A)

HPEX240 40GQSFP+to4x10GSFP+5mDirectAttachCopperSplitterCable(JG331A)

Page 23Data sheet

HPEX140 40GQSFP+LCLR4SM10km1310nmTransceiver(JG661A)

HPEX140 40GQSFP+MPOMM850nmCSR4 300mTransceiver(JG709A)

HPEX140 40GQSFP+LCBiDi100mMMTransceiver(JL251A)

HPEX140 40GQSFP+LCLR4L2kmSMTransceiver(JL286A)

HPEX2A0 40GQSFP+toQSFP+7mActiveOpticalCable(JL287A)

HPEX2A0 40GQSFP+toQSFP+10mActiveOpticalCable(JL288A)

HPEX2A0 40GQSFP+toQSFP+20mActiveOpticalCable(JL289A)

HPEX240 100GQSFP28toQSFP28 5mDirectAttachCopperCable(JL273A)

HPEX240 100GQSFP28toQSFP28 1mDirectAttachCopperCable(JL271A)

HPEX240 100GQSFP28toQSFP28 3mDirectAttachCopperCable(JL272A)

HPEX150 100GQSFP28MPOSR4 100mMMTransceiver(JL274A)

HPEX150 100GQSFP28LCLR4 10kmSMTransceiver(JL275A)

HPEX150 100GQSFP28LCSWDM4100mMMTransceiver(JH419A)

HPEX150 100GQSFP28CWDM4 2kmSMTransceiver(JH673A)

HPE58x0AF650WACPowerSupply(JC680A)

HPEFlexFabric5930 4-slotBack(PowerSide)toFront(PortSide)AirflowFanTray(JH185A)

HPEFlexFabric5930 4-slotFront(PortSide)toBack(PowerSide)AirflowFanTray(JH186A)

Switch bundlesSelectHPEFlexFabricSwitch5940modelsareavailablewithpowersuppliesandfantraysincluded.

HPEFlexFabric5940 2-slot2QSFP+Front-to-BackACBundle(JQ041A):Includes(1)HPEFlexFabric5940 2-slotSwitch(JH397A),(2)powersupplies(JC680A),(2)front-to-backfantrays(JG552A).

HPEFlexFabric5940 2-slot2QSFP+Back-to-FrontACBundle(JQ042A):Includes(1)HPEFlexFabric5940 2-slotSwitch(JH397A),(2)powersupplies(JC680A),(2)back-to-frontfantrays(JG553A)

HPEFlexFabric5940 4-slotFront-to-BackACBundle(JQ043A):Includes(1)HPEFlexFabric5940 4-slotSwitch(JH398A),(4)powersupplies(JC680A),(2)front-to-backfantrays(JH186A)

HPEFlexFabric5940 4-slotBack-to-FrontACBundle(JQ044A):Includes(1)HPEFlexFabric5940 4-slotSwitch(JH398A),(4)powersupplies(JC680A),(2)back-to-frontfantrays(JH185A)

Learnmoreathpe.com/networking

Sign up for updates

Make the right purchase decision. Click here to chat with our presales specialists.

Data sheet

©Copyright2016–2018HewlettPackardEnterpriseDevelopmentLP.Theinformationcontainedhereinissubjecttochangewithoutnotice.TheonlywarrantiesforHewlettPackardEnterpriseproductsandservicesaresetforthintheexpresswarrantystatementsaccompanyingsuchproductsandservices.Nothinghereinshouldbeconstruedasconstitutinganadditionalwarranty.HewlettPackardEnterpriseshallnotbeliablefortechnicaloreditorialerrorsoromissionscontainedherein.

TheOpenStackWordMarkiseitheraregisteredtrademark/servicemarkortrademark/servicemarkoftheOpenStackFoundation,intheUnitedStatesandothercountriesandisusedwiththeOpenStackFoundation’spermission.Wearenotaffiliatedwith,endorsedorsponsoredbytheOpenStackFoundation,ortheOpenStackcommunity.sFlowisaregisteredtrademarkofInMonCorp.Allotherthird-partytrademark(s)is/arepropertyoftheirrespectiveowner(s).

4AA6-6465ENN,May2018,Rev.11