View
6
Download
0
Category
Preview:
Citation preview
Huachuang Animation Industrial Park, Guangzhou, Guangdong, Chinawww.dotels.cn www.axen-heatpump.com
Dotels Technology Co., Ltd
DST00-C1904
DST00-C
1801 Heat Pu
mp
Heat Pump
ECO Friendly
Dotels, as a professional heat pump manufacture, is established in 2007,and focus on R&D, manufacture air to water heat pump equipments.
7 product linesLocated in Guangzhou
80,000 units per year6 product lines
Located in Wuhan
180,000 units per year
Dotels headquaters Wuhan production bases
2018 Found the commercial heat pump division;
2017 Launched the swimming pool heat pump with R32 refrigerant system;
2017 Launched the wave inverter series swimming pool heat pump;
2017 Built the manufacture basement in Wuhan;
2015 Expanded the productive capacity in Guangzhou production basement.
2014 Established Dotels brand;
2010 Launched the swimming pool heat pump;
2008 Entered the heat pump �eld;
Dotels Milestone
Dotels Sales Volume - Millions USD
ISO9001-2015Quality Management System forquality assuranceCerti�cate No.: 02815Q10078R1M
ISO14001-2015Environmental Management SystemCerti�cate No.: 02816E10166R1M
ISO/IEC 17025-2005, CNAS-CL01Laboratory issued by CNASCerti�cate No.: CNAS L10796
Year
2008
2010
2014
2015
2017
2018
2012 2013
2.67 6.28 11.6 17.6
78.2
155.0
214.6
2014 2015 2016 2017 2018 (Year)
03 04
Contents
Why choose an air to water heat pump? 4
Swimming Pool Heat Pump 7
Product lineups 5
Wave Inverter Series 9
Fan Coil Units 38
Console H/P 41
Chillers 30
Sanitary Hot Water Heat Pump 22
Jetline Series 15
Summer Line Series 19
ECO Series 17
Controller 20
Apolo Series 24
Alps Series 26
Comfort Series 27
ECO Series 28
Top Part 29
Air Cooled Modular Chillers 31
Water Cooled Modular chillers 34
Air Cooled Screw Chillers 36
Mini Pac 21
Why choose an air to water heat pump?
Air to water heat pump is renewable.Air to water heat pump only uses less energy than furnaces, gas / electric water heater. The heat pump product absorbs energy from the surrounding air of the outdoor unit and transfers the energy into the refrigerant of the unit. The heat energy is upgraded using a refrigerant cycle and this renewable heat energy is transferred in the water by heat-exchanger.
Air to water heat pump has great �nancial bene�ts.Air to water heat pump will most likely save a lot of money on your annual fuel bills due to the unit’s high COP (Coe�cient of performance). When the unit can achieve COP between 3 - 4, meaning the unit can produce 3kW to 4kW of heat for every 1kW power consummed.
Heat from thesurrounding air
Power consummed
Heat energyoutput3kW
1kW
4kW
Air to water heat pump is more reliable.
Air to water heat pump
Safe to operate Risk of �re and explosion
Expensive to operate Expensive to operate Expensive to operate
Expensive to install Lifespan of several yearsLifespan of several years
Risk of electric shocks Risk of �re and explosion
Easy for installation
Cheap to operate
Gas water heater Electric water heater Boiler
Air to water heat pump is help to decrease your carbon footprint.Compared with gas water heater and boiler, because heat pump water heater does not directly use combustion to generate heat, the unit don’t cause as much pollution and have a smaller carbon footpring. Air to water heat pump only need a small amount of electricity to run the compressor and fan motor. Comparison of the power needed to heat 1 ton water from 15ºC to 55ºC under the same conditions:
Air to water HP
Consumption
Average e�ciency
Calori�c value
Energy resource GasAir & electricity
24,000kcal/m3
2.08m3
10,200kcal/kg
5.6kg
4.6 0.70.8 0.95
860kcal/kW.h
10kW.h
860kcal/kW.h
48.9kW.h
Electricity Diesel oil
Gas water heater Electric water heater Boiler
05 06
Product LineupsSwimming Pool Heat Pumps
Series
R329 - 14
15 - 16
17 - 18
19 - 20
21
R410A
R32
R32
R410A
R32
R32
R410A
Heating capacity range (kW)3.0 30.020.010.0 15.0 25.0
Pages
Wave inverter series
Jetline series
ECO series
Summer line series
Mini Pac series
5.3 31.7
5.3 31.7
R410A4.7 28.2
3.3 22.0
8.3 13.3
4.7 10.5
4.5 11.77
4.5 11.77
3.0 4.5
Sanitary Hot Water Heat Pumps (R134a)
Series
24 - 25
26
27
28
Heating capacity/Tank volume0.9kW/80L 2.0kW/300L2.0kW/200L0.9kW/100L 2.0kW/150L 2.0kW/250L
Pages
Apolo series
Alps series
Comfort series
ECO series
Series
29
Heating capacity range0.9kW 2.0kW
Pages
Top part
Chillers
Series
31 - 33
Cooling capacity range30.0kW 65.0kW 130.0kW
Pages
R410A Air cooled modular chillers
Series
34 - 35
Cooling capacity range73.4kW 110.1kW 146.8kW
Pages
R410A Water cooled modular chillers
Console H/P (R410A)
Series
42
42
Heating capacity3.00kW 4.00kW
Pages
Indoor unit
Outdoor unit
Fan coil units
Series
39 - 40
Air �ow (@ high speed) (CFM)200 300 400 500 600 1,000 1,200 1,400800
Pages
Concealed duct
237.3 1,084.6
Series
36 - 37
Cooling capacity range200kW 400kW 600kW 800kW 1,000kW 1,200kW
Pages
R134a Air cooled screw chillers
07 08
Swimming Pool
Heat Pump
Swimming Pool
Heat Pump
Dotels swimming pool heat pump is one of the most economical system to heat your swimming pool e�ciently and will substantially reduce your pool running costs. It’s a good swimming pool solution that Dotels swimming pool heat pump is combined with the pool �ltration and pumping system.
Plastic cabinet
Galvanized steelcabinet
High e�ciency
Titaniumheat-exchanger
Anti-UV cover
Plug & play
Pressure gauge
Wi-FiWi-Fi
Convenient installationIt is very convenience that only inlet/outlet water pipes and electricity cables need to connect.LCD controller with large screen as standard, and 15m shield cable as optional.Inlet and outlet water pipe connectors, drainage pipe for condensing water and rubber gaskets for unit �xing as assessories. (Except Mini PAC)
Operating reliabilityMulti-protections, including pressure protections, water �ow protection, temperature protections.When there is malfunction happened, diagnosis will be automatically made and the result will be displayed in controller screen.Built-in automatic 4-way valve for defrost. (Except Mini PAC)
Waveinverter series Jet lines series Summer line
seriesECO series Mini PAC
General Features
Plastic ABS cabinet(For swimming pool HPs except ECO series)
Plastic ABS panels, excellent weather resistance, pass 72 hours Weatherability Test.
Galvaized steel cabinet (For ECO series)
Powder-coated panel for galvaized steel cabinet made of galvanized steel passes 1,000 hours Salt Spray Test.
Anti-UV cover as optional (Except Mini PAC)
Anti-UV cover is made of silver plasters. The cover will provide products good protection during the idle period of the product.Titanium tube
heat-exchangerSpiral Titanium
tube
Prolonged operating lifeSpiral titanium tube heat-exchanger
Titanium tube with PVC casing provides superior corrosion resistance.Spiral tube design, expand the surface area of the Titanium tube and water to provide heater transfer at a great rate.
Yes
Yes
Yes Yes Yes
Yes
Yes
-----
----- -----
----- -----
----- -----
-----
-----
-----
-----
-----
-----
Yes
Yes
Yes Yes Yes Yes
Yes Yes Yes Yes
Yes
Yes Yes
Yes Yes Yes
Yes Yes Yes Yes
09 10
Plastic cabinetHigh e�ciency
Titanumheat-exchanger
Anti-UV coverPressure gauge
Wi-FiWi-Fi
Wave Inverter SeriesFiWi
Full DCInverter
Save energy and money with high e�cient running
Well-known brand compressor: GMCC, twin-rotary (except size 031 & 032), DC inverter technology, more e�cient.High e�cient brushless DC motor running with low noise.Thanks to electronic expansion valve, more accurate for refrigerant control.High COP/EER performance to save engergy and money.Notes: The swimming pool capacity is 45m3, and the temperature keeps 26ºC.
Heating Capacity
(DTSP035 @A26ºC, RH80%/inlet water 26ºC)
COP
100% 80% 50% 20%
4
8
12
16
6.15
14.6
10.4
7.8
0
Heating Capacity
(DTSP035 @A15ºC, RH70%/inlet water 26ºC)
COP 4.9
0
2
4
6
8
100% 80% 50% 20%
7.6
5.96.7
20%
Cooling Capacity
(DTSP035 @35ºC/inlet water 28ºC)
7.46.9
5.64.41
EER
0
2
4
6
8
50%80%100%
Settingtemperature
Time
Full wave inverterunitON/OFF unit
Time
Full wave inverterunit
ON/OFF unit
Startcurrent
On On
O�
HP start
Stable running and high reliable
Full DC inverter technology, the unit can keep more stable running than ON/OFF unit, and keep the temperature of the pool water more accurate.
Soft start design to guarantee the safety of whole house’s electricity supply. When the unit start to working, the current will slowly increase from 0A.
Super quiet GMCC compressor and DC motor help full wave inverter heat pump to quiet running.With CFD air �ow technology, newly designed fan blower and outlet grille bring super quiet and high e�cient opera-tion.
Three modes design, maximise your pool season
Boost Mode
20% - 100% capacity output
Fast heating
Late spring/early autumn in cooler climate
Boost
20% - 80% capacity output
As standard
Spring to Autumn in warm climate
Smart Mode
Smart
20% - 50% capacity output
Using at night
Middle of summer in hot climate
Silent Mode
Silent
Time
Wat
er te
mpe
ratu
re
Boos
t mod
eSm
art m
ode
Silen
t mode
Runn
ing
freq
uenc
y
Water temperatureTS2
F1
F0
Boost mode
Smart mode
Silent modeF2
TS1TSet
Super silence, much quieter
Model
Sound pressure level (@4m)
Sound pressure level (@10m)
dB(A)
dB(A)
27.4 - 35.8
DTSP031 (N8) DTSP032 (N8) DTSP033 (N8) DTSP034 (N8) DTSP035 (N8)
29.5 - 36.6 29.4 - 37.3 30.4 - 37.9 30.6 - 38.2
19.1 - 27.2 19.5 - 27.4 20.5 - 27.9 20.6 - 28.2 20.8 - 28.6
Model
Sound pressure level (@4m)
Sound pressure level (@10m)
dB(A)
dB(A)
32.8 - 40.5
DTSP036 (N8) DTSP037 (N8) DTSP038 (N8) DTSP040 (N8)DTSP039 (N8) DTSP041 (N8)
33.2 - 40.9 35.3 - 41.1 36.4 - 44.7 37.9 - 46.9
23.0 - 31.8 23.6 - 32.2 24.3 - 33.4 26.6 - 36.5
35.6 - 41.8
24.6 - 33.7 27.3 - 38.2
Controller
11 12
Speci�cations - R32
Notes:1. Advised pool volume for the pool with isothermal cover.2. The speci�cation may be changed for product improvement, please refer to the nameplate of product.
Model DTSP031N8 DTSP032N8 DTSP034N8DTSP033N8
Advised pool volume 10m3 - 20m3
Operating ambient air temperature
kW
kW
kW
mm
mm
mm
kg
Pcs
5.10 - 7.90
1.60 - 5.30
1.50 - 2.80
4.51 - 7.55
6.25 - 14.50
1.10 - 3.80
Performance condition 1 - Air: 26°C, RH80%, inlet / outlet water temperature: 26°C / 28°C.
Performance condition 2 - Air: 15°C, RH70%, inlet water / outlet temperature: 26°C / 28°C.
Performance condition 3 - Air: 35°C DB, inlet / outlet water temperature: 28°C / 26°C.
Heating capacity
COP
Heating capacity
COP
Cooling capacity
EER
Dimension
Net / Gross weight
Loading (40HQ / 20GP)
Unit (W×D×H)
Packing (W×D×H)
R32
Φ50
2 - 3
860×330×668
950×410×800
35 / 42
15m3 - 30m3
4.80 - 7.80
1.60 - 7.20
1.70 - 3.60
4.48 - 7.53
6.22 - 14.55
-5°C - 43°C
1.30 - 5.10
-5°C - 43°C
R32
Φ50
3 - 4
860×330×668
950×410×800
38 / 45
20m3 - 40m3
5.00 - 7.70
1.90 - 9.20
1.80 - 4.60
4.47 - 7.46
6.24 - 14.71
1.60 - 6.70
-5°C - 43°C
R32
Φ50
3 - 5
860×330×668
950×410×800
40 / 48
210 / 68210 / 68
25m3 - 50m3
4.90 - 7.80
2.70 - 10.90
2.40 - 6.00
4.32 - 7.34
6.27 - 14.80
2.18 - 8.13
-5°C - 43°C
R32
Φ50
4 - 6
986×356×668
1,080×435×800
44 / 54
168 / 56
230V~, 1Ph, 50Hz 230V~, 1Ph, 50Hz 230V~, 1Ph, 50Hz 230V~, 1Ph, 50Hz
210 / 68
Refrigerant type
Power supply
Inlet /outlet water pipes
Advised water �ow m3/h
Model DTSP035N8
Advised pool volume
Operating ambient air temperature
kW
kW
kW
mm
mm
mm
kg
Pcs
Performance condition 1 - Air: 26°C, RH80%, inlet / outlet water temperature: 26°C / 28°C.
Performance condition 2 - Air: 15°C, RH70%, inlet water / outlet temperature: 26°C / 28°C.
Performance condition 3 - Air: 35°C DB, inlet / outlet water temperature: 28°C / 26°C.
Heating capacity
COP
Heating capacity
COP
Cooling capacity
EER
Dimension
Net / Gross weight
Loading (40HQ / 20GP)
Unit (W×D×H)
Packing (W×D×H)
30m3 - 60m3
4.90 - 7.60
3.40 - 14.30
3.20 - 7.87
4.41 - 7.42
6.15 - 14.62
2.86 - 10.65
-5°C - 43°C
R32
230V~, 1Ph, 50Hz
Φ50
5 - 7
986×356×668
1,080×435×800
46 / 56
168 / 56
Refrigerant type
Power supply
Inlet /outlet water pipes
Advised water �ow m3/h
DTSP036N8 DTSP037N8 DTSP038N8
35m3 - 70m3
4.85 - 7.44
4.30 - 17.40
3.90 - 9.60
4.24 - 7.40
6.00 - 14.50
3.49 - 13.00
R32
Φ50
6 - 8
986×356×668
1,080×435×800
56 / 66
40m3 - 80m3
5.10 - 7.52
4.80 - 21.20
4.30 - 11.50
4.38 - 7.48
6.36 - 14.55
-5°C - 43°C
3.76 - 15.70
-5°C - 43°C
R32
Φ50
7 - 9
1,076×426×720
1,161×490×855
67 / 80
60m3 - 100m3
4.80 - 7.50
5.70 - 23.20
5.30 - 12.80
4.17 - 7.25
6.10 - 14.50
4.64 - 17.34
-5°C - 43°C
R32
Φ50
8 - 10
1,076×426×720
1,161×490×855
70 / 83
129 / 42129 / 42
230V~, 1Ph, 50Hz 230V~, 1Ph, 50Hz 230V~, 1Ph, 50Hz
168 / 56
Speci�cations - R410A
Model DTSP031 DTSP032 DTSP034DTSP033
Advised pool volume 10m3 - 20m3
Operating ambient air temperature
kW
kW
kW
mm
mm
mm
kg
Pcs
5.10 - 7.90
1.60 - 5.30
1.50 - 2.80
4.51 - 7.55
6.25 - 14.50
1.10 - 3.80
Performance condition 1 - Air: 26°C, RH80%, inlet / outlet water temperature: 26°C / 28°C.
Performance condition 2 - Air: 15°C, RH70%, inlet water / outlet temperature: 26°C / 28°C.
Performance condition 3 - Air: 35°C DB, inlet / outlet water temperature: 28°C / 26°C.
Heating capacity
COP
Heating capacity
COP
Cooling capacity
EER
Dimension
Net / Gross weight
Loading (40HQ / 20GP)
Unit (W×D×H)
Packing (W×D×H)
R410A
Φ50
2 - 3
860×330×668
950×410×800
35 / 42
15m3 - 30m3
4.80 - 7.80
1.60 - 7.20
1.70 - 3.60
4.48 - 7.53
6.22 - 14.55
-10°C - 43°C
1.30 - 5.10
-10°C - 43°C
R410A
Φ50
3 - 4
860×330×668
950×410×800
38 / 45
20m3 - 40m3
5.00 - 7.70
1.90 - 9.20
1.80 - 4.60
4.47 - 7.46
6.24 - 14.71
1.60 - 6.70
-10°C - 43°C
R410A
Φ50
3 - 5
860×330×668
950×410×800
40 / 48
210 / 68210 / 68
25m3 - 50m3
4.90 - 7.80
2.70 - 10.90
2.40 - 6.00
4.32 - 7.34
6.27 - 14.80
2.18 - 8.13
-10°C - 43°C
R410A
Φ50
4 - 6
986×356×668
1,080×435×800
44 / 54
168 / 56
230V~, 1Ph, 50Hz 230V~, 1Ph, 50Hz 230V~, 1Ph, 50Hz 230V~, 1Ph, 50Hz
210 / 68
Refrigerant type
Power supply
Inlet /outlet water pipes
Advised water �ow m3/h
Notes:1. Advised pool volume for the pool with isothermal cover.2. The speci�cation may be changed for product improvement, please refer to the nameplate of product.
Model DTSP039N8 DTSP040N8 DTSP041N8
Advised pool volume
Operating ambient air temperature
kW
kW
kW
mm
mm
mm
kg
Pcs
Performance condition 1 - Air: 26°C, RH80%, inlet / outlet water temperature: 26°C / 28°C.
Performance condition 2 - Air: 15°C, RH70%, inlet water / outlet temperature: 26°C / 28°C.
Performance condition 3 - Air: 35°C DB, inlet / outlet water temperature: 28°C / 26°C.
Heating capacity
COP
Heating capacity
COP
Cooling capacity
EER
Dimension
Net / Gross weight
Loading (40HQ / 20GP)
Unit (W×D×H)
Packing (W×D×H)
65m3 - 110m3
4.91 - 7.53
6.20 - 25.10
5.80 - 13.90
4.15 - 7.22
6.20 - 14.52
5.15 - 18.52
-5°C - 43°C
R32
Φ50
8 - 11
1,076×426×720
1,161×490×855
72 / 85
129 / 42
70m3 - 130m3
4.95 - 7.51
6.60 - 29.00
6.20 - 16.00
4.29 - 7.54
6.10 - 14.54
5.43 - 21.28
-5°C - 43°C
R32
Φ50
9 - 12
1,176×451×822
1,261×515×957
90 / 108
80 / 38
80m3 - 150m3
4.90 - 7.60
7.70 - 31.70
7.20 - 17.50
4.21 - 7.44
6.11 - 14.60
6.34 - 23.68
-5°C - 43°C
R32
230V~, 1Ph, 50Hz 230V~, 1Ph, 50Hz 230V~, 1Ph, 50Hz
Φ50
12 - 15
1,176×451×822
1,261×515×957
98 / 116
80 / 38
Refrigerant type
Power supply
Inlet /outlet water pipes
Advised water �ow m3/h
Notes:1. Advised pool volume for the pool with isothermal cover.2. The speci�cation may be changed for product improvement, please refer to the nameplate of product.
Model DTSP035
Advised pool volume
Operating ambient air temperature
kW
kW
kW
mm
mm
mm
kg
Pcs
Performance condition 1 - Air: 26°C, RH80%, inlet / outlet water temperature: 26°C / 28°C.
Performance condition 2 - Air: 15°C, RH70%, inlet water / outlet temperature: 26°C / 28°C.
Performance condition 3 - Air: 35°C DB, inlet / outlet water temperature: 28°C / 26°C.
Heating capacity
COP
Heating capacity
COP
Cooling capacity
EER
Dimension
Net / Gross weight
Loading (40HQ / 20GP)
Unit (W×D×H)
Packing (W×D×H)
30m3 - 60m3
4.90 - 7.60
3.40 - 14.30
3.20 - 7.87
4.41 - 7.42
6.15 - 14.62
2.86 - 10.65
-10°C - 43°C
R410A
230V~, 1Ph, 50Hz
Φ50
986×356×668
1,080×435×800
46 / 56
168 / 56
Refrigerant type
Power supply
Inlet /outlet water pipes
Advised water �ow m3/h
DTSP036 DTSP037 DTSP038
35m3 - 70m3
4.85 - 7.44
4.30 - 17.40
3.90 - 9.60
4.24 - 7.40
6.00 - 14.50
3.49 - 13.00
R410A
Φ50
6 - 85 - 7
986×356×668
1,080×435×800
56 / 66
40m3 - 80m3
5.10 - 7.52
4.80 - 21.20
4.30 - 11.50
4.38 - 7.48
6.36 - 14.55
-10°C - 43°C
3.76 - 15.70
-10°C - 43°C
R410A
Φ50
7 - 9
1,076×426×720
1,161×490×855
67 / 80
60m3 - 100m3
4.80 - 7.50
5.70 - 23.20
5.30 - 12.80
4.17 - 7.25
6.10 - 14.50
4.64 - 17.34
-10°C - 43°C
R410A
Φ50
8 - 10
1,076×426×720
1,161×490×855
70 / 83
129 / 42129 / 42
230V~, 1Ph, 50Hz 230V~, 1Ph, 50Hz 230V~, 1Ph, 50Hz
168 / 56
Model DTSP039 DTSP040 DTSP041
Advised pool volume
Operating ambient air temperature
kW
kW
kW
mm
mm
mm
kg
Pcs
Performance condition 1 - Air: 26°C, RH80%, inlet / outlet water temperature: 26°C / 28°C.
Performance condition 2 - Air: 15°C, RH70%, inlet water / outlet temperature: 26°C / 28°C.
Performance condition 3 - Air: 35°C DB, inlet / outlet water temperature: 28°C / 26°C.
Heating capacity
COP
Heating capacity
COP
Cooling capacity
EER
Dimension
Net / Gross weight
Loading (40HQ / 20GP)
Unit (W×D×H)
Packing (W×D×H)
65m3 - 110m3
4.91 - 7.53
6.20 - 25.10
5.80 - 13.90
4.15 - 7.22
6.20 - 14.52
5.15 - 18.52
-10°C - 43°C
R410A
Φ50
8 - 11
1,076×426×720
1,161×490×855
72 / 85
129 / 42
70m3 - 130m3
4.95 - 7.51
6.60 - 29.00
6.20 - 16.00
4.29 - 7.54
6.10 - 14.54
5.43 - 21.28
-10°C - 43°C
R410A
Φ50
9 - 12
1,176×451×822
1,261×515×957
90 / 108
80 / 38
80m3 - 150m3
4.90 - 7.60
7.70 - 31.70
7.20 - 17.50
4.21 - 7.44
6.11 - 14.60
6.34 - 23.68
-10°C - 43°C
R410A
230V~, 1Ph, 50Hz 230V~, 1Ph, 50Hz 230V~, 1Ph, 50Hz
Φ50
12 - 15
1,176×451×822
1,261×515×957
98 / 116
80 / 38
Refrigerant type
Power supply
Inlet /outlet water pipes
Advised water �ow m3/h
Controller
Applications sketch
Model LWC02-V03
Dimensions (W×H) 115mm × 135mm
Power supply
Screen LCD
DC 12V (From unit’s PCB)
Other functions
Wi-Fi function Standard, built-in Wi-Fi module
1. There are 3 modes, Boost, Smart and Silent, under cooling or heating mode.2. Ambient temperature and pool temperature are displayed. 3. Operating parameter query function.4. Backlight, standard for orange color.5. Error check function.
By-passvalve
Automatedprocessing system
2-wayvalve
2-wayvalve
Drainagevalve
2-wayvalve
FiltrationPump
From pool
To pool
2-wayvalve
Swimming poolHeat pump
13 14
Plastic cabinetHigh e�ciency
Titanumheat-exchanger
Anti-UV coverPressure gauge
Wi-FiWi-Fi
Jetline SeriesFiWi
Speci�cations - R32
Model DTSP-05N8-J DTSP-07N8-J DTSP-13N8-JDTSP-09N8-J
Advised pool volume 25m3 - 35m3
Operating ambient air temperature
kW
kW
kW
mm
mm
dB(A)
mm
kg
Pcs
4.99
4.70
3.25
3.12
6.38
4.01
Performance condition 1 - Air: 27°C DB / 24°C WB, inlet / outlet water temperature: 27°C / 28°C.
Performance condition 2 - Air: 15°C DB / 12°C WB, inlet water / outlet temperature: 26°C / 28°C.
Performance condition 3 - Air: 35°C DB, inlet / outlet water temperature: 28°C / 26°C.
Heating capacity
COP
Heating capacity
COP
Cooling capacity
EER
Dimension
Net / Gross weight
Loading (40HQ / 20GP)
Unit (W×D×H)
Packing (W×D×H)
R32
220-240V~, 1Ph, 50Hz 220-240V~, 1Ph, 50Hz 220-240V~, 1Ph, 50Hz 220-240V~, 1Ph, 50Hz
Φ50
1.9
18
895×340×610
965×394×755
40 / 50
30m3 - 40m3
4.96
6.80
4.14
3.09
6.50
-5°C - 43°C
5.06
-5°C - 43°C
R32
Φ50
2.6
18
895×340×610
965×394×755
45 / 55
35m3 - 50m3
5.01
8.10
6.88
3.48
6.42
7.10
-5°C - 43°C
R32
Φ50
2.9
20
923×360×661
993×414×806
51 / 66
192 / 62201 / 96
45m3 - 65m3
5.09
10.50
7.98
3.62
6.61
9.11
-5°C - 43°C
R32
Φ50
3.9
21
923×360×661
993×414×806
58 / 73
192 / 62201 / 96
Refrigerant type
Power supply
Inlet /outlet water pipes
Advised water �ow
Sound pressure level (@4m)
m3/h
Controller: KS139135
Notes:1. Advised pool volume for the pool with isothermal cover.2. The speci�cation may be changed for product improvement, please refer to the nameplate of product.
Speci�cations - R410A
Notes:1. Advised pool volume for the pool with isothermal cover.2. The speci�cation may be changed for product improvement, please refer to the nameplate of product.
Model AXSPS-30 AXSPS-40 AXSPS-70AXSPS-50
Advised pool volume 20m3 - 25m3
Operating ambient air temperature
kW
kW
kW
mm
mm
dB(A)
mm
kg
Pcs
5.01
4.70
2.67
3.21
6.38
3.10
Performance condition 1 - Air: 27°C DB / 24°C WB, inlet / outlet water temperature: 27°C / 29°C.
Performance condition 2 - Air: 15°C DB / 12°C WB, inlet water / outlet temperature: 26°C / 28°C.
Performance condition 3 - Air: 35°C DB, inlet / outlet water temperature: 28°C / 26°C.
Heating capacity
COP
Heating capacity
COP
Cooling capacity
EER
Dimension
Net / Gross weight
Loading (40HQ / 20GP)
Unit (W×D×H)
Packing (W×D×H)
R410A
220-240V~, 1Ph, 50Hz 220-240V~, 1Ph, 50Hz 220-240V~, 1Ph, 50Hz 220-240V~, 1Ph, 50Hz
Φ50
1.4
36
895×370×610
922×370×740
38 / 48
25m3 - 35m3
4.99
6.80
3.25
3.12
6.50
-7°C - 43°C
4.01
-7°C - 43°C
R410A
Φ50
1.9
37
895×370×610
922×370×740
40 / 50
30m3 - 40m3
4.96
8.10
4.14
3.09
6.42
5.06
-7°C - 43°C
R410A
Φ50
2.5
38
895×370×610
922×370×740
45 / 55
231 / 108231 / 108
35m3 - 50m3
5.01
10.50
6.88
3.48
6.61
7.10
-7°C - 43°C
R410A
Φ50
3.4
38
923×410×661
950×410×786
51 / 66
210 / 68231 / 108
Refrigerant type
Power supply
Inlet /outlet water pipes
Advised water �ow
Sound pressure level (@4m)
m3/h
220-240V~, 1Ph, 50Hz 220-240V~, 1Ph, 50Hz 220-240V~, 1Ph, 50Hz 220-240V~, 1Ph, 50Hz
Model AXSPS-90 AXSPS-110 AXSPS-160 AXSPS-180AXSPS-130
Advised pool volume 45m3 - 65m3
Operating ambient air temperature
kW
kW
kW
mm
mm
dB(A)
mm
kg
Pcs
5.09
13.90
7.98
3.62
6.65
9.11
Performance condition 1 - Air: 27°C DB / 24°C WB, inlet / outlet water temperature: 27°C / 29°C.
Performance condition 2 - Air: 15°C DB / 12°C WB, inlet water / outlet temperature: 26°C / 28°C.
Performance condition 3 - Air: 35°C DB, inlet / outlet water temperature: 28°C / 26°C.
Heating capacity
COP
Heating capacity
COP
Cooling capacity
EER
Dimension
Net / Gross weight
Loading (40HQ / 20GP)
Unit (W×D×H)
Packing (W×D×H)
R410A
Φ50
4.2
39
923×410×661
950×410×786
58 / 73
50m3 - 75m3
5.05
16.20
9.31
3.32
6.57
-7°C - 43°C
11.04
-7°C - 43°C
R410A
Φ50
5.0
39
923×410×661
950×410×786
63 / 78
60m3 - 85m3
5.01
18.20
10.60
3.18
6.46
13.01
-7°C - 43°C
R410A
Φ50
6.0
40
1,215×485×713
1,242×485×844
72 / 90
126 / 40210 / 68
80m3 - 110m3
4.92
23.30
12.95
3.01
6.38
16.06
-7°C - 43°C
R410A
Φ50
7.3
40
1,215×485×713
1,242×485×844
95 / 113
126 / 40
380-420V~, 3Ph, 50Hz
90m3 - 120m3
5.04
28.20
15.73
3.16
6.44
19.43
-7°C - 43°C
R410A
Φ50
7.7
44
1,200×494×887
1,280×494×1,056
105 / 125
84 / 38210 / 68
Refrigerant type
Power supply
Inlet /outlet water pipes
Advised water �ow
Sound pressure level (@4m)
m3/h
15 16
High e�ciency
Titanumheat-exchanger
Anti-UV coverPressure gauge
Wi-FiWi-Fi
ECO SeriesFiWi
Speci�cations - R32
Controller: KS139135
Notes:1. Advised pool volume for the pool with isothermal cover.2. The speci�cation may be changed for product improvement, please refer to the nameplate of product.
Speci�cations - R410A
Notes:1. Advised pool volume for the pool with isothermal cover.2. The speci�cation may be changed for product improvement, please refer to the nameplate of product.
Model KY-30N8-B01 KY-50N8-B01 KY-90N8-B01KY-70N8-B01
Advised pool volume 15m3 - 20m3
Operating ambient air temperature
kW
kW
kW
mm
mm
dB(A)
mm
kg
Pcs
5.92
3.30
3.71
3.64
4.65
4.50
Performance condition 1 - Air: 27°C DB / 24°C WB, inlet / outlet water temperature: 27°C / 29°C.
Performance condition 2 - Air: 15°C DB / 12°C WB, inlet / outlet water temperature: 26°C / 28°C.
Performance condition 3 - Air: 35°C DB, inlet / outlet water temperature: 28°C / 26°C.
Heating capacity
COP
Heating capacity
COP
Cooling capacity
EER
Dimension
Net / Gross weight
Loading (40HQ / 20GP)
Unit (W×D×H)
Packing (W×D×H)
R32
Φ50
2.0
35
816×307×553
885×360×670
37 / 41
20m3 - 30m3
5.72
4.80
4.57
3.29
4.53
-5°C - 43°C
6.41
-5°C - 43°C
R32
Φ50
3.0
36
816×307×553
885×360×670
40 / 46
30m3 - 40m3
5.79
7.10
7.13
3.48
4.58
9.15
-5°C - 43°C
R32
Φ50
5.0
37
913×367×718
1,010×450×851
47 / 53
210 / 68231 / 108
40m3 - 50m3
5.80
9.13
9.16
3.50
4.66
11.77
-5°C - 43°C
R32
220-240V~, 1Ph, 50Hz 220-240V~, 1Ph, 50Hz 220-240V~, 1Ph, 50Hz 220-240V~, 1Ph, 50Hz
Φ50
8.0
38
913×367×718
1,010×450×851
54 / 60
210 / 68231 / 108
Refrigerant type
Power supply
Inlet /outlet water pipes
Advised water �ow
Sound pressure level (@4m)
m3/h
Model ECO-30 ECO-55 ECO-100ECO-70
Advised pool volume 10m3 - 15m3
Operating ambient air temperature
kW
kW
kW
mm
mm
dB(A)
mm
kg
Pcs
6.01
2.75
2.71
3.20
4.66
3.30
Performance condition 1 - Air: 27°C DB / 24°C WB, inlet / outlet water temperature: 27°C / 29°C.
Performance condition 2 - Air: 15°C DB / 12°C WB, inlet water / outlet temperature: 26°C / 28°C.
Performance condition 3 - Air: 35°C DB, inlet / outlet water temperature: 28°C / 26°C.
Heating capacity
COP
Heating capacity
COP
Cooling capacity
EER
Dimension
Net / Gross weight
Loading (40HQ / 20GP)
Unit (W×D×H)
Packing (W×D×H)
R410A
Φ50
1.65
35
816×303×553
885×360×670
37 / 41
15m3 - 20m3
6.06
4.35
3.38
3.02
4.70
-7°C - 43°C
5.78
-7°C - 43°C
R410A
Φ50
2.8
35
816×303×553
885×360×670
39 / 43
20m3 - 30m3
6.00
4.85
3.78
3.01
4.65
7.01
-7°C - 43°C
R410A
Φ50
3.5
36
816×303×553
885×360×670
40 / 44
231 / 108231 / 108
30m3 - 45m3
6.08
6.90
5.38
3.20
4.71
10.00
-7°C - 43°C
R410A
220-240V~, 1Ph, 50Hz 220-240V~, 1Ph, 50Hz 220-240V~, 1Ph, 50Hz 220-240V~, 1Ph, 50Hz
Φ50
4.8
37
913×367×718
1,010×450×851
47 / 53
210 / 68231 / 108
Refrigerant type
Power supply
Inlet /outlet water pipes
Advised water �ow
Sound pressure level (@4m)
m3/h
Model ECO-130 ECO-180 ECO-220 ECO-220TECO-180T
Advised pool volume 40m3 - 55m3
Operating ambient air temperature
kW
kW
kW
mm
mm
dB(A)
mm
kg
Pcs
6.06
8.56
6.68
3.10
4.70
12.50
Performance condition 1 - Air: 27°C DB / 24°C WB, inlet / outlet water temperature: 27°C / 29°C.
Performance condition 2 - Air: 15°C DB / 12°C WB, inlet water / outlet temperature: 26°C / 28°C.
Performance condition 3 - Air: 35°C DB, inlet / outlet water temperature: 28°C / 26°C.
Heating capacity
COP
Heating capacity
COP
Cooling capacity
EER
Dimension
Net / Gross weight
Loading (40HQ / 20GP)
Unit (W×D×H)
Packing (W×D×H)
R410A
Φ50
6.2
38
913×367×718
1,010×450×851
54 / 60
65m3 - 80m3
6.11
12.80
9.98
3.10
4.74
-7°C - 43°C
18.00
-7°C - 43°C
R410A
Φ50
7.0
40
942×398×817
1,022×458×952
63 / 73
65m3 - 80m3
6.11
12.80
9.98
3.10
4.74
18.00
-7°C - 43°C
R410A
Φ50
7.0
40
942×398×817
1,022×458×952
63 / 73
126 / 40210 / 68
80m3 - 100m3
6.04
14.68
11.45
3.01
4.68
22.00
-7°C - 43°C
R410A
Φ50
8.0
41
942×398×817
1,022×458×952
75 / 85
126 / 40
80m3 - 100m3
6.04
14.68
11.45
3.01
4.68
22.00
-7°C - 43°C
R410A
Φ50
8.0
41
942×398×817
1,022×458×952
75 / 85
126 / 40210 / 68
Refrigerant type
Power supply
Inlet /outlet water pipes
Advised water �ow
Sound pressure level (@4m)
m3/h
220-240V~, 1Ph, 50Hz 220-240V~, 1Ph, 50Hz 380-415V~, 3Ph, 50Hz 380-415V~, 3Ph, 50Hz220-240V~, 1Ph, 50Hz
Galvanized steelcabinet
17 18
19 20
Controller
Speci�cations - R410A
Notes:1. Advised pool volume for the pool with isothermal cover.2. The speci�cation may be changed for product improvement, please refer to the nameplate of product.
Plastic cabinetHigh e�ciency
Titanumheat-exchanger
Anti-UV coverPressure gauge
Wi-FiWi-Fi
Summer Line SeriesFiWi
Speci�cations - R32
Controller: KS139135
Notes:1. Advised pool volume for the pool with isothermal cover.2. The speci�cation may be changed for product improvement, please refer to the nameplate of product.
Model KY-30N8-B01 KY-50N8-B01 KY-90N8-B01KY-70N8-B01
Advised pool volume 15m3 - 20m3
Operating ambient air temperature
kW
kW
kW
mm
mm
dB(A)
mm
kg
Pcs
5.92
3.30
3.71
3.64
4.65
4.50
Performance condition 1 - Air: 27°C DB / 24°C WB, inlet / outlet water temperature: 27°C / 29°C.
Performance condition 2 - Air: 15°C DB / 12°C WB, inlet / outlet water temperature: 26°C / 28°C.
Performance condition 3 - Air: 35°C DB, inlet / outlet water temperature: 28°C / 26°C.
Heating capacity
COP
Heating capacity
COP
Cooling capacity
EER
Dimension
Net / Gross weight
Loading (40HQ / 20GP)
Unit (W×D×H)
Packing (W×D×H)
R32
Φ50
2.0
35
816×307×553
885×360×670
37 / 41
20m3 - 30m3
5.72
4.80
4.57
3.29
4.53
-5°C - 43°C
6.41
-5°C - 43°C
R32
Φ50
3.0
36
816×307×553
885×360×670
40 / 46
30m3 - 40m3
5.79
7.10
7.13
3.48
4.58
9.15
-5°C - 43°C
R32
Φ50
5.0
37
913×367×718
1,010×450×851
47 / 53
210 / 68231 / 108
40m3 - 50m3
5.80
9.13
9.16
3.50
4.66
11.77
-5°C - 43°C
R32
220-240V~, 1Ph, 50Hz 220-240V~, 1Ph, 50Hz 220-240V~, 1Ph, 50Hz 220-240V~, 1Ph, 50Hz
Φ50
8.0
38
913×367×718
1,010×450×851
54 / 60
210 / 68231 / 108
Refrigerant type
Power supply
Inlet /outlet water pipes
Advised water �ow
Sound pressure level (@4m)
m3/h
Model AXSPS-68 AXSPS-108AXSPS-88
Advised pool volume 25m3 - 35m3
Operating ambient air temperature
kW
kW
kW
mm
mm
dB(A)
mm
kg
Pcs
6.61
6.29
4.86
2.89
4.88
8.30
Performance condition 1 - Air: 27°C DB / 24°C WB, inlet / outlet water temperature: 27°C / 29°C.
Performance condition 2 - Air: 15°C DB / 12°C WB, inlet water / outlet temperature: 26°C / 28°C.
Performance condition 3 - Air: 35°C DB, inlet / outlet water temperature: 28°C / 26°C.
Heating capacity
COP
Heating capacity
COP
Cooling capacity
EER
Dimension
Net / Gross weight
Loading (40HQ / 20GP)
Unit (W×D×H)
Packing (W×D×H)
R410A
Φ50
3.10
35
1,075×400×667
1,110×410×813
49 / 64
-7°C - 43°C
35m3 - 50m3
6.65
8.28
7.39
2.98
4.90
10.80
-7°C - 43°C
R410A
Φ50
3.95
36
1,075×400×667
1,110×410×813
54 / 69
231 / 108
50m3 - 65m3
6.76
10.18
8.79
2.90
4.89
13.30
-7°C - 43°C
R410A
220-240V~, 1Ph, 50Hz 220-240V~, 1Ph, 50Hz 220-240V~, 1Ph, 50Hz
Φ50
4.80
37
1,075×400×667
1,110×410×813
61 / 76
210 / 68231 / 108
Refrigerant type
Power supply
Inlet /outlet water pipes
Advised water �ow
Sound pressure level (@4m)
m3/h
Model KS139135
Dimensions (W×H) 86mm × 86mm
Power supply
Screen LCD
DC 12V (From unit’s PCB)
Other functions
Wi-Fi function Customized (Wi-Fi kit should be connected with controller)
1. 24 hours real time clock.2. Ambient temperature and setting temperature are displayed. 3. Operating parameter query function.4. Backlight, standard for orange color.5. Error check function.
2221
Sanitary Hot Water
Heat Pump
Sanitary Hot Water
Heat Pump
Mini Pac
Speci�cations - R32
Notes:1. Advised pool volume for the pool with isothermal cover.2. The speci�cation may be changed for product improvement, please refer to the nameplate of product.
Model
Advised pool volume
Operating ambient air temperature
kW
kW
mm
mm
dB(A)
mm
kg
Pcs
Performance condition 1 - Air: 27°C DB / 24°C WB, inlet / outlet water temperature: 27°C / 29°C.
Performance condition 2 - Air: 15°C DB / 12°C WB, inlet / outlet water temperature: 26°C / 28°C.
Heating capacity
COP
Heating capacity
COP
Dimension
Net / Gross weight
Loading (40HQ / 20GP)
Unit (W×D×H)
Packing (W×D×H)
DTSP-025mini
7m3 - 10m3
4.41
2.20
3.61
3.00
2.0
R32
DN32
310×300×358
370×350×388
20 / 24
7°C - 35°C
32
220-240V~, 1Ph, 50Hz
1,224 / 480
DTSP-045mini
10m3 - 18m3
4.40
3.40
3.58
4.50
2.0
R32
DN32
370×435×460
420×460×490
28 / 31
7°C - 35°C
32
220-240V~, 1Ph, 50Hz
650 / 260
Refrigerant type
Power supply
Inlet /outlet water pipes
Advised water �ow
Sound pressure level (@10m)
m3/h
High e�ciency
Titanumheat-exchanger Plug & play
Galvanized steelcabinet
Controller: RC-112E
23 24
Dotels sanitary hot water heat pump will simultaneously cool down the room and provide hot water to cover allyour daily needs. The units are by all means the most energy e�cient and cost e�ective way of water heating. Saves money and contributes to a cleaner environment.
General FeaturesHigh e�ciency Flexible air duct connections
60Pa static pressure ensure that the inlet and outlet air duct total equivalent length is up to 8m.
High reliableThanks to EXV control technology, accuracy control of refrigerant is achieved.Multi-protections are available: Over-load protection of compressor, Temperature on/o� protection, High pressure switch and Low pressure switch.Automatic anti-legionella per week, more reliable and health.
Convenient installation & operationAdopt all-in-one design, only plumber installations and plugging in.User-friendly screen controller with LED display.Operating status and error codes can be clearly displayed on controller screen.
Utilization of varies heat sourcesCompatible with solar panel, solar PV and other heat sources, like boilers. (Customized)
Well-known, GMCC, compressor, high e�ciency.Adopt D-shape pipe to increase conduction heating surface between refrigerant pipe and inner water tank and high e�cient ratio of heat-exchanger.
D-shape aluminium pipe as standard,D-shape copper pipe as option.
Cool and fresh air
Fromoutdoor
Apolo SeriesErP energy class: A
Ambient temperature: -5°C to 43°C
Setting temperature: 10°C to 70°C
Default 50°C
* Stainless steel water tank. Built-in solar pipe is optional.
Model AXHW-20a-200L AXHW-20a-250L AXHW-20a-300L
Power supply 220 - 240V~, 50Hz, 1Ph
Nominal tank volume L
kW
kW
W
mm
mm
mm
kg
Pcs
486
2.588
450
°C 60
°C 70
A
2.02
1.6
200
Heating capacity (Heat pump only) #
EBH (Electric backup heater)
Input (Heat pump only) #
COP*
ErP energy class
Air �ow
Available
Dimension
Net / Gross weight
Loading (40GP / 20GP)
Unit (ΦD×H)
Packing (L×W×H)
About 2 - 3 peoples
Rotary
R134a / EXV
G3/4’
G3/4’
G1/2‘
177
Φ560×1,750
615×615×1,870
90 / 100
80 / 40
220 - 240V~, 50Hz, 1Ph
486
2.164
450
60
70
A
2.02
1.6
250
About 4 - 5 peoples
Rotary
R134a / EXV
G3/4’
G3/4’
G1/2‘
177
Φ640×1,633
695×695×1,753
100 / 112
51 / 27
220 - 240V~, 50Hz, 1Ph
486
2.708
450
60
70
A
2.02
1.6
300
About more than 6 peoples
Rotary
R134a / EXV
G3/4’
G3/4’
G1/2‘
177
Φ640×1,845
695×695×1,965
110 / 122
51 / 27
Compressor
Refrigerant type / control
Inlet / Outlet water pipe connection
Drainage water connection
Condensing water connection
Duct diameter of air inlet / outlet
m3/h
Heat pump onlyMax.leaving watertemperature
Heat pump + EBH
Notes:#: Test condition - ambient temperature is 20°C DB/12°C WB, water temperature is from 15°C to 55°C.*: Test condition - EN16147, XL, ambient temperature is7°C DB/6°C WB, water temperature is from 10°C to 53°C.The speci�cation may be changed for product improvement, please refer to the nameplate of product.
25 26
Apolo SeriesErP energy class: A+ or A
Ambient temperature: -5°C to 43°C
Setting temperature: 10°C to 70°C
Default 50°C
* Stainless steel water tank. Built-in solar pipe is optional.
Model AXHW-20a-200L(H2) AXHW-20a-250L(H2) AXHW-20a-300L(H2)
Power supply 220 - 240V~, 50Hz, 1Ph
Nominal tank volume L
kW
kW
W
mm
mm
mm
kg
Pcs
700
2.588
450
°C
60°C
70
A
2.02
1.6
200
Heating capacity (Heat pump only) #
EBH (Electric backup heater)
Max. input (Heat pump only) #
COP*
ErP energy class
Air �ow
Available
Dimension
Net / Gross weight
Loading (40GP / 20GP)
Unit (ΦD×H)
Packing (L×W×H)
About 2 - 3 peoples
Rotary
R134a / EXV
G3/4’
G3/4’
G1/2‘
177
Φ560×1,750
615×615×1,870
90 / 100
80 / 40
220 - 240V~, 50Hz, 1Ph
700
2.164
450
60
70
A
2.02
1.6
250
About 4 - 5 peoples
Rotary
R134a / EXV
G3/4’
G3/4’
G1/2‘
177
Φ640×1,633
695×695×1,753
100 / 112
51 / 27
220 - 240V~, 50Hz, 1Ph
700
2.708
450
60
70
A
2.02
1.6
300
About more than 6 peoples
Rotary
R134a / EXV
G3/4’
G3/4’
G1/2‘
177
Φ640×1,845
695×695×1,965
110 / 122
51 / 27
Compressor
Refrigerant type / control
Inlet / Outlet water pipe connection
Drainage water connection
Condensing water connection
Duct diameter of air inlet / outlet
m3/h
Heat pump onlyMax. leaving watertemperature
Heat pump + EBH
Notes:#: Test condition - ambient temperature is 20°C DB/12°C WB, water temperature is from 15°C to 55°C.*: Test condition - EN16147, XL, ambient temperature is7°C DB/6°C WB, water temperature is from 10°C to 53°C.The speci�cation may be changed for product improvement, please refer to the nameplate of product.
Alps SeriesErP energy class: A
Ambient temperature: -5°C to 43°C
Setting temperature: 10°C to 70°C
Default 50°C
* Stainless steel water tank. Built-in solar pipe is optional.
Model AXHW-20a-200L AXHW-20a-250L AXHW-20a-300L
Power supply 220 - 240V~, 50Hz, 1Ph
Nominal tank volume L
kW
kW
W
mm
mm
mm
kg
Pcs
700
2.588
450
°C 60
°C 70
A
2.02
1.6
200
Heating capacity (Heat pump only) #
EBH (Electric backup heater)
Max. input (Heat pump only) #
COP*
ErP energy class
Air �ow
Available
Dimension
Net / Gross weight
Loading (40GP / 20GP)
Unit (ΦD×H)
Packing (L×W×H)
About 2 - 3 peoples
Rotary
R134a / EXV
G3/4’
G3/4’
G1/2‘
177
Φ560×1,750
615×615×1,870
90 / 100
80 / 40
220 - 240V~, 50Hz, 1Ph
700
2.164
450
60
70
A
2.02
1.6
250
About 4 - 5 peoples
Rotary
R134a / EXV
G3/4’
G3/4’
G1/2‘
177
Φ640×1,633
695×695×1,753
100 / 112
51 / 27
220 - 240V~, 50Hz, 1Ph
700
2.708
450
60
70
A
2.02
1.6
300
About more than 6 peoples
Rotary
R134a / EXV
G3/4’
G3/4’
G1/2‘
177
Φ640×1,845
695×695×1,965
110 / 122
51 / 27
Compressor
Refrigerant type / control
Inlet / Outlet water pipe connection
Drainage water connection
Condensing water connection
Duct diameter of air inlet / outlet
m3/h
Heat pump onlyMax. leaving watertemperature
Heat pump + EBH
Notes:#: Test condition - ambient temperature is 20°C DB/12°C WB, water temperature is from 15°C to 55°C.*: Test condition - EN16147, XL, ambient temperature is7°C DB/6°C WB, water temperature is from 10°C to 53°C.The speci�cation may be changed for product improvement, please refer to the nameplate of product.
27
Comfort SeriesErP energy class: A
Ambient temperature: -7°C to 43°C
Setting temperature: 10°C to 70°C
Default 50°C
ECO Series (Wall-mounted)ErP energy class: A
Ambient temperature: -7°C to 43°C
Setting temperature: 10°C to 70°C
Default 50°C
* Enamel water tank. * Enamel water tank.
Model AXHW-20c-150L AXHW-20c-200L AXHW-20c-250L
Power supply 220 - 240V~, 50Hz, 1Ph
Nominal tank volume L
kW
kW
W
mm
mm
mm
mm
mm
mm
kg
Pcs
497
3.80
450
°C 70
°C 70
A
1.9
2.0
150
Heating capacity (Heat pump only)
EBH (Electric backup heater)
Max. input (Heat pump only)
COP
ErP energy class
Air �ow
Available
Dimension
Net / Gross weight
Loading (40GP / 20GP)
Unit (ΦD×H)
Packing (L×W×H)
About 2 - 3 peoples
Rotary
R134a / EXV
DN15
DN15
Φ9
177
Φ510×1,730
600×585×1,830
81 / 100
80 / 40
220 - 240V~, 50Hz, 1Ph
497
3.80
450
70
70
A
1.9
2.0
200
About 4 - 5 peoples
Rotary
R134a / EXV
DN15
DN15
Φ9
177
Φ570×1,747
710×680×1,842
102 / 112
51 / 27
220 - 240V~, 50Hz, 1Ph
497
3.80
450
70
70
A
1.9
2.0
250
About more than 6 peoples
Rotary
R134a / EXV
DN15
DN15
Φ9
177
Φ570×2,015
710×680×2,110
115 / 122
51 / 27
Compressor
Refrigerant type / control
Inlet / Outlet water pipe connection
Drainage water connection
Condensing water connection
Duct diameter of air inlet / outlet
m3/h
Heat pump onlyMax. leaving watertemperature
Heat pump + EBH
Notes:1. Test condition - ambient temperature is 20°C DB/12°C WB, water temperature is from 15°C to 55°C.2. The speci�cation may be changed for product improvement, please refer to the nameplate of product.
28
Model RSJ-09/080RD RSJ-09/100RD
Power supply 220-240V~, 50Hz, 1Ph
Nominal tank volume L
kW
kW
W
mm
mm
mm
kg
Pcs
250
3.53
120
°C 70
°C 70
A
0.9
1.2
80
Heating capacity (Heat pump only)
EBH (Electric backup heater)
Input (Heat pump only)
COP
ErP energy class
Air �ow
Dimension
Net / Gross weight
Loading (40GP / 20GP)
Unit (ΦD×H)
Packing (L×W×H)
Rotary
R134a / EXV
G1/2’’
G1/2’’
120
Φ410×1,485
520×510×1,650
46 / 66
88 / 44
220-240V~, 50Hz, 1Ph
250
3.53
120
70
70
A
0.9
1.2
100
Rotary
-7°C - 43°C -7°C - 43°C
R134a / EXV
G1/2’’
G1/2’’
120
Φ410×1,515
520×510×1,680
51 / 71
88 / 44
Compressor
Refrigerant type / control
Inlet water pipe connection
Outlet water pipe connection
Duct diameter of air inlet / outlet
Notes:Test condition - ambient temperature is 20°C DB/12°C WB, water temperature is from 15°C to 55°C.The speci�cation may be changed for product improvement, please refer to the nameplate of product.
m3/h
Heat pump only
Operating ambient temperature
Max. leaving watertemperature Heat pump + EBH
30
Chillers Chillers
29
Top PartErP energy class: A
Ambient temperature: -5°C to 43°C
Setting temperature: 10°C to 70°C
Default 50°C
Model AXHW-9a AXHW-20a AXHW-20b
Power supply 220 - 240V~, 50Hz, 1Ph
Suggesting tank volume L
kW
m3/h
mm
mm
kg
kg
Pcs
Rotary
R134a
kg Null
Without casing
mm Null
mm Φ9.52
EXV
1.00
250
80 - 100
Heating capacity (Heat pump only) #
Air �ow
Compressor
Refrigerant
Type
Factory charged
Control
Casing
DimensionUnit (ΦD×H)
Packing (L×W×H)
Φ464×365
540×488×405
18
28
368 / 176
220 - 240V~, 50Hz, 1Ph
Rotary
R134a
Null
Plastic
177
Φ9.52
EXV
2.00
450
200 - 300
Φ520×425
695×695×530
25
29
204 / 96
220 - 240V~, 50Hz, 1Ph
Rotary
R134a
0.92
Plastic
177
Φ9.52, stop valves
EXV
2.00
450
200 - 300
Φ550×410
695×695×553
25
29
204 / 96
Net weight
Gross weight
Loading (40GP / 20GP)
Notes:#: Test condition - ambient temperature is 20°C DB/12°C WB,water temperature is from 15°C to 55°C.The speci�cation may be changed for product improvement, please refer to the nameplate of product.
Duct diameter of air inlet / outlet
Refrigerant pipe between tank and top part
Panel AAXHW-20a
Panel BAXHW-20b
31 32
Air Cooled Modular Chillers
Speci�cations - R410A
Model DTS-KAC-300R/DS-A
Cooling
kW
Btu/h
kW
Outdoor ambient temperature
kW
kW
kW
A
Fan type / Quantity
Type
kPaWater resistance loss
Water �ow
Type / Quantity
10.0
32.0
Cooling: 10°C - 46°C; Heating: -10°C - 21°C
9.8
24.0
12.6
102,300
30.0
Input
InputHeating
Max. input
Max. current
Dimension
Net / Gross weight kg
Air �ow
mm
mm
mm
Loading (40HQ / 20GP)
Sound pressure level
Air side heat-exchanger
Water sideheat-exchanger
Water pipeInlet / outlet pipe ID
Connection type
Fan motor
R410A / EXV +Capillary
320 / 340
65
18 / 8
1,100×1,953×919
1,120×1,953×919
Fin coil
Axial / 1
Shell and tube
12,000
Danfoss Copeland
380 - 450V~, 3Ph, 50Hz
DTS-KAC-700R/DS-A
20.4
69.0
21.5
28.2
47.6
221,780
65.0
Fixed scroll / 1 Digital scroll / 1
Danfoss Copeland
Fixed scroll / 1 Digital scroll / 1
R410A / EXV +Capillary
2,014×1,953×919
2,034×1,953×939
590 / 610
67
12 / 4
Fin coil
Axial / 2
Shell and tube
24,000
380 - 400V~, 3Ph, 50Hz
40
11.2
DN65 / DN65
Flexible jointFlexible joint
DN50 / DN50
5.3
40
Power supply
Refrigerant type / Control
CompressorBrand
dB(A)
Unit (W×D×H)
Packing (W×D×H)
m3/h
m3/h
DTS-KAC-300R/S-A
10.0
32.0
9.8
24.0
12.6
102,300
30.0
Fixed scroll / 1
R410A / EXV +Capillary
320 / 340
65
18 / 8
1,100×1,953×919
1,120×1,953×919
Fin coil
Axial / 1
Shell and tube
12,000
Danfoss
380 - 450V~, 3Ph, 50Hz
Flexible joint
DN50 / DN50
5.3
40
Notes:1. All the above datas are based on the following condition: Cooling - Water side fouling factor is 0.086m2.°C/kW; Entering/leaving chilled water temperature is 12°C/7°C; Outdoor ambient temperature is 35°C. Heating - Water side fouling factor is 0.086m2.°C/kW; Entering/leaving chilled water temperature is 40°C/45°C; Outdoor ambient temperature is 7°CDB/6°CWB.2. The speci�cation may be changed for product improvement, please refer to the nameplate of product.
Capacity
Capacity
Wired controller
FeaturesProlonged operating life & High reliable
Reliable key componentsDanfoss compressor CXH140 with optimized interleaving scrolls, fewer moving parts and smooth operating. (Copeland compressor as optional)Adopt shell and tube heat-exchanger with higher-pressure applications for water side.The fan motors’ protective level meets IP55 and insulation class meets F level.Metal fan is designed with excellent anti-corrosion performance.Advanced microcomputer control system with powerful error diagnostics, andmain protection functions are: over-load protection, high pressure protection,low pressure protedction, anti-freezing protection, over-heating protection, temperature sensor detection and power supply detection.
Motor & fan
Backup functionWhen one of the slave units is failed or in protecting status, other slave units will still keep running.
Master Slave 1 Slave 2 Slave 3 Master Slave 1 Slave 2 Slave 3
Running
StopFault
Any unit can operate as the master when a group of units are combined. It will covercome the problem where if a master unit were to fault, the entire system would then shut down.
Master Slave 1 Slave 2 Slave 3 Master Newmaster Slave 2 Slave 3
Running
StopFault
Widely used applicationsFlexible capacity
Cooling capacityCompressor Qty
65kW
30kW
30kW
65kW
130kW
2
Fixed Digital
4
/
1 1
11 1
/
/
DTS-KAC-700R/S-A
DTS-KAC-1400R/S-A
DTS-KAC-300R/S-A
DTS-KAC-700R/DS-A
DTS-KAC-300R/DS-A
Combined units
Max. quantity
16
16
16
16
1,040kW
1,040kW
1,040kW
1,104kW
1,104kW
480kW
480kW
512kW
512kW
1,104kW8
Max. cooling capacity Max. heating capacityModel
Wide outlet water temperature
Mode
Cooling
Heating
Temperature range of outlet water
Standard
5°C - 17°C 0°C - 17°C
22°C - 50°C40°C - 50°C
Customized
3433
Water Cooled Modular ChillersSpeci�cations - R410A
Model DTS-KAC-700R/S-A DTS-KAC-1400R/S-A
Cooling
kW
Btu/h
kW
Outdoor ambient temperature
kW
kW
kW
A
Fan type / Quantity
Type
kPaWater resistance loss
Water �ow
Type / Quantity
20.4 40.8
69.0 138.0
21.5
Cooling: 10°C - 46°C; Heating: -10°C - 21°C Cooling: 10°C - 46°C; Heating: -10°C - 21°C
43.0
28.2
47.6 93.8
55.5
221,780 443,560
65.0 130.0
Input
InputHeating
Max. input
Max. current
Dimension
Net / Gross weight kg
Air �ow
mm
mm
mm
Loading (40HQ / 20GP)
Sound pressure level
Air side heat-exchanger
Water sideheat-exchanger
Water pipeInlet / outlet pipe ID
Connection type
Fan motor
Fixed scroll / 2 Fixed scroll / 4
R410A / EXV +Capillary R410A / EXV +Capillary
2,014×1,953×919
2,034×1,953×939
590 / 610
67
1,080 / 1,100
70
12 / 4 5 / 2
2,014×2,117×1,964
2,034×2,117×1,984
Fin coil Fin coil
Axial / 2 Axial / 4
Shell and tube Shell and tube
24,000 48,000
Danfoss Danfoss
380 - 400V~, 3Ph, 50Hz 380 - 400V~, 3Ph, 50Hz
40
11.2
DN65 / DN65
Flexible joint Flexible joint
DN65 / DN65
22.4
60
Power supply
Refrigerant type / Control
CompressorBrand
dB(A)
Unit (W×D×H)
Packing (W×D×H)
m3/h
m3/h
Notes:1. All the above datas are based on the following condition: Cooling - Water side fouling factor is 0.086m2.°C/kW; Entering/leaving chilled water temperature is 12°C/7°C; Outdoor ambient temperature is 35°C. Heating - Water side fouling factor is 0.086m2.°C/kW; Entering/leaving chilled water temperature is 40°C/45°C; Outdoor ambient temperature is 7°CDB/6°CWB.2. The speci�cation may be changed for product improvement, please refer to the nameplate of product.
Capacity
Capacity
FeaturesAdvanced refrigerant system design
Adopt unbalance parallel technology for compressor to maintain the safe oil levelEnsure that return oil is equally devided, and unitform crankcase pressure and oil level are purposely kept in equilibration parallel system. The dynamic technology ranks the compressors according to the crankcase pressure levels, and return oil is not distributed equally but according to the order based on the ranks.Famous brand scroll compressor, fewer moving parts and smooth operating.Backup function is available in the group of compressors, and operation with part load is achieved.
Fit and �exibilityModular design to achieve expandable arrays. Cooling capacity for the water-cooled scroll chillers can be ampli�ed whith up to 8 units.Space-conscious design elements, the chillers can be widely suitable for many commerical and industrial applictions, including education, healthcare, hospital and govermant building.All units are factory assembled, charged and run tested to ensure a smooth and trouble-free installation.Adopt intelligence PLC control system and user-friendly interface. It is convenient to be used.RS485 port is reserved.
Simpler service and low running costThanks for fewer moving parts, the reliability of scroll compress is improved.No need to take as long for mechanical team to perform routine maintenance tasks. Translate to a lower cost per service and a lower cost of ownership over the life of the equipment. Automatically record operating histories, so it is easy to inquiry the error or protection informations.
Unbalance parallel technology
35 36
Speci�cations - R410A
Model DTS-WAC-75MCB/Na DTS-WAC-110MCB/Na DTS-WAC-150MCB/Na
CoolingkW
kW
RefrigerantControl
Type
Type
Entering water temp °C
°C
°C
°C
Type
Leaving water temp
kPa
kPa
Water �ow
Water resistance loss
Water �ow
380V~, 3Ph, 50Hz 40.8
Scroll Scroll
2
R410A R410A
4
Thermal expansion valve
Shell and tube heat-exchanger
Thermal expansion valve
15.23 30.46
73.4 146.8
Input
QuantityCompressor
Evaporator
Unit dimension
Net weight kg
kg
Entering water temp
mm
mm
mm
mm
mm
Operating weight
Gross weight
Water pipe joint
Water pipe joint
Width
Condenser
12.62 25.25
7 7
750
1,400
680
700
1,180
1,200
820 1,420
800
1,600
DN65 DN80
Shell and tube heat-exchanger
35 35
30 30
35 45
12 12
15.24
45
DN65
2,300
380V~, 3Ph, 50Hz
Scroll
3
R410A
Thermal expansion valve
22.85
110.1
18.93
7
750
1,400
880
900
1,060
DN65
35
30
45
12
22.86
55
DN65
2,300 2,500
DN80
55
30.48
Power supply
Leaving water temp
Water resistance loss
kg
Depth
Height
m3/h
m3/h
Notes:1. All the above datas are based on the following condition: Cooling - Entering/leaving chilled water temperature is 12°C/7°C; Entering/leaving cooled water temperature is 30°C/35°C. 2. The speci�cation may be changed for product improvement, please refer to the nameplate of product.
Capacity
Type
1
Notes:1. All the above datas are based on the following condition: Cooling - Entering/leaving chilled water temperature is 12°C/7°C; Outdoor ambient temperature is 35°C. Heating - Leaving chilled water temperature is 45°C; Outdoor ambient temperature is 7°CDB/6°CWB.2. The speci�cation may be changed for product improvement, please refer to the nameplate of product.
Speci�cations - R134a
Model DTS-255LAB/Nb
CoolingCapacity kW
kW
Compressor
Type
kW
kW
Type
Air �ow
kPaMotor input
Dimensions
Water �ow
73.1
261.0
Semi-hermetic, screw compressor
72.6
25% - 100%
1
237.3
380V~, 3Ph, 50Hz
Input
InputHeating
Quantity
Capacity step
kg
Fan type×Qty.
mm
Net weight
Condenser
Shell and tube heat-exchanger
3,724×2,340×2,580
Fan coil heat-exchanger
108,000
Axial×6
55.1
R134a
DTS-425LAB/Nb
110.4
405.2
109.9
25% - 100%
368.3
380V~, 3Ph, 50Hz
40.8
58.9
63.4
4,964×2,340×2,580
Fan coil heat-exchanger
144,000
Axial×8
R134a
12.0
5,0002,750
9.0
Refrigerant type
Evaporator
kPa
Type
Pressure drop
Unit (W×D×H)
m3/h
m3/h
DTS-310LAB/Nb
84.8
299.7
85.4
25% - 100%
1
272.4
380V~, 3Ph, 50Hz
46.9
4,964×2,340×2,580
Fan coil heat-exchanger
144,000
Axial×8
43.8
R134a
4,500
12.0
Power supply
Capacity
Leaving water temperatureMode Outdoor ambient temperatureDi�. water temperature
between leaving and entering
Cooling 5°C - 15°C 2.5°C - 6°C 15°C - 48°C
-15°C - 24°C2.5°C - 6°C40°C - 50°CHeating
Air Cooled Screw Chillers
3837
Fan Coil UnitsFan Coil Units
Speci�cations - R134a
Model DTS-550LAB/Nb
CoolingCapacity kW
kW
Compressor
Type
kW
kW
Type
Air �ow
kPaMotor input
Dimensions
Water �ow
138.7
526.6
Semi-hermetic, screw compressor
139.8
25% - 100%
1
478.7
380V~, 3Ph, 50Hz
Input
InputHeating
Quantity
Capacity step
kg
Fan type×Qty.
mm
Net weight
Condenser
Shell and tube heat-exchanger
6,204×2,340×2,580
Fan coil heat-exchanger
180,000
Axial×10
44.4
R134a
DTS-850LAB/Nb
220.9
810.4
219.9
2
12.5% - 100%
736.7
380V~, 3Ph, 50Hz
82.3
62.7
126.7
9,924×2,340×2,580
Fan coil heat-exchanger
288,000
Axial×16
R134a
24.0
10,0005,600
15.0
Refrigerant type
Evaporator
kPa
Type
Pressure drop
Unit (W×D×H)
m3/h
m3/h
DTS-620LAB/Nb
160.5
596.5
161.7
25% - 100%
1
542.3
380V~, 3Ph, 50Hz
93.3
7,130×2,380×2,560
Fan coil heat-exchanger
252,000
Axial×14
49.1
R134a
6,800
21.0
Power supply
Capacity
Notes:1. All the above datas are based on the following condition: Cooling - Entering/leaving chilled water temperature is 12°C/7°C; Outdoor ambient temperature is 35°C. Heating - Leaving chilled water temperature is 45°C; Outdoor ambient temperature is 7°CDB/6°CWB.2. The speci�cation may be changed for product improvement, please refer to the nameplate of product.
Model DTS-975LAB/Nb
CoolingCapacity kW
kW
Compressor
Type
kW
kW
Type
Air �ow
kPaMotor input
Dimensions
Water �ow
249.2
931.8
Semi-hermetic, screw compressor
249.7
12.5% - 100%
2
847.1
380V~, 3Ph, 50Hz
Input
InputHeating
Quantity
Capacity step
kg
Fan type×Qty.
mm
Net weight
Condenser
Shell and tube heat-exchanger
11,164×2,340×2,580
Fan coil heat-exchanger
324,000
Axial×18
67.1
R134a
DTS-1240LAB/Nb
321.1
1,193.0
323.4
2
12.5% - 100%
1,084.6
380V~, 3Ph, 50Hz
145.7
44.8
186.5
14,260×2,380×2,560
Fan coil heat-exchanger
504,000
Axial×28
R134a
42.0
13,60010,600
27.0
Refrigerant type
Evaporator
kPa
Type
Pressure drop
Unit (W×D×H)
m3/h
m3/h
DTS-1100LAB/Nb
277.5
1,053.2
279.6
12.5% - 100%
2
957.5
380V~, 3Ph, 50Hz
164.7
12,404×2,340×2,580
Fan coil heat-exchanger
360,000
Axial×20
37.8
R134a
11,200
30.0
Power supply
Capacity
19 4037
Speci�cations - AC Motor
Model DTS-FP200-TYA DTS-FP300-TYA DTS-FP400-TYA
Air �ow (H / M / L)340 / 270 / 190m3/h
kW
Pa
L/h
kWCooling
Heating
CFM
kPa
dB(A)
mm
mm
kg
Pcs
3.30 / 2.85 / 2.33
G3/4’’
Standard: 12; customized: 30Pa and 50Pa
11
Water �ow
34 36 38
Inlet & Outlet water pipe
Capacity (H / M / L)
External static pressure
Water pressure drop
Sound pressure level (@12Pa)
Drainage pipe
Dimension
Net / Gross weight
Loading (40HQ / 40 / 20GP)
Unit (W×D×H)
Packing (W×D×H)
G3/4’’
653×461×228
700×510×242
690 / 621 / 297
510 / 390 / 290
4.68 / 4.13 / 3.33
G3/4’’
G3/4’’
200 / 159 / 112
22
300 / 229 / 171
793×461×228
840×510×242
12 / 13 13 / 14
600 / 540 / 261
680 / 540 / 400
5.98 / 5.19 / 4.16
2.10 / 1.84 / 1.43 2.90 / 2.54 / 1.99 3.80 / 3.37 / 2.65
G3/4’’
G3/4’’
13.5
360 520 680
400 / 318 / 235
893×461×228
940×510×242
15 / 16.5
470 / 423 / 207
220V~, 1Ph, 50Hz 220V~, 1Ph, 50Hz 220V~, 1Ph, 50HzPower supply
Model DTS-FP500-TYA DTS-FP600-TYA DTS-FP800-TYA
Air �ow (H / M / L)850 / 660 / 490m3/h
kW
Pa
L/h
kWCooling
Heating
CFM
kPa
dB(A)
mm
mm
kg
Pcs
7.12 / 6.12 / 5.12
G3/4’’
Standard: 12; customized: 30Pa and 50Pa
21
Water �ow
42 45 46
Inlet & Outlet water pipe
Capacity (H / M / L)
External static pressure
Water pressure drop
Sound pressure level (@12Pa)
Drainage pipe
Dimension
Net / Gross weight
Loading (40HQ / 40 / 20GP)
Unit (W×D×H)
Packing (W×D×H)
G3/4’’
973×461×228
1,020×510×242
460 / 414 / 198
1,020 / 790 / 590
8.46 / 7.28 / 6.09
G3/4’’
G3/4’’
500 / 388 / 288
28
600 / 465 / 347
1,073×461×228
1,120×510×242
16.5 / 18 19 / 20.5
460 / 414 / 198
1,360 / 1,050 / 800
11.60 / 9.98 / 8.35
4.70 / 4.11 / 3.22 5.60 / 4.88 / 3.82 7.55 / 6.58 / 5.14
G3/4’’
G3/4’’
29
780 920 1,280
800 / 618 / 471
1,403×461×228
1,450×510×242
27 / 29
310 / 279 / 135
220V~, 1Ph, 50Hz 220V~, 1Ph, 50Hz 220V~, 1Ph, 50HzPower supply
Model DTS-FP1000-TYA DTS-FP1200-TYA DTS-FP1400-TYA
Air �ow (H / M / L)1,700 / 1,350 / 1,000m3/h
kW
Pa
L/h
kWCooling
Heating
CFM
kPa
dB(A)
mm
mm
kg
Pcs
13.90 / 11.96 / 9.99
G3/4’’
Standard: 12; customized: 30Pa and 50Pa
17
Water �ow
48 49 51
Inlet & Outlet water pipe
Capacity (H / M / L)
External static pressure
Water pressure drop
Sound pressure level (@12Pa)
Drainage pipe
Dimension
Net / Gross weight
Loading (40HQ / 40 / 20GP)
Unit (W×D×H)
Packing (W×D×H)
G3/4’’
1,503×461×228
1,550×510×242
300 / 270 / 126
2,040 / 1,620 / 1,200
16.50 / 14.20 / 11.88
G3/4’’
G3/4’’
1,000 / 794 / 588
25
1,200 / 953 / 706
1,803×461×228
1,850×510×242
30.5 / 32.5 36 / 38.5
240 / 216 / 108
2,380 / 1,890 / 1,400
19.20 / 16.52 / 13.82
9.26 / 7.98 / 6.40 11.16 / 9.54 / 7.48 12.80 / 11.13 / 8.96
G3/4’’
G3/4’’
28
1,580 1,860 2,160
1,400 / 1,112 / 824
2,013×461×228
2,060×510×242
39 / 43
230 / 207 / 99
220V~, 1Ph, 50Hz 220V~, 1Ph, 50Hz 220V~, 1Ph, 50HzPower supply
Notes:1. The parameters are based on the following conditions: Cooling - Return air temperature 27°CDB/19°CWB; entering water temperature is 7°C, and leaving water temperature is 12°C. Hooling - Return air temperature 21°C; entering water temperature is 50°C.2. The speci�cation may be changed for product improvement, please refer to the nameplate of product.
Notes:1. The parameters are based on the following conditions: Cooling - Return air temperature 27°CDB/19°CWB; entering water temperature is 7°C, and leaving water temperature is 12°C. Hooling - Return air temperature 21°C; entering water temperature is 50°C.2. The speci�cation may be changed for product improvement, please refer to the nameplate of product.
Concealed Duct FCUs
42
Notes:1. The speci�cation may be changed for product improvement, please refer to the nameplate of product.
Console H/P
Speci�cations - R410A
Indoor unit
Outdoor unit
RFC-30G/BP-A RFC-40G/BPh-A
RFC-30W/BP-A
Operating ambient air temperature
kW
kW
kW
mm
mm
dB(A)
mm
kg
kg
2.15
3.00
3.19
3.26
4.10
3.00
Performance condition 1 - Air: -20°C DB / 24°C WB, entering air temperature: 20°C.
Performance condition 2 - Air: 7°C DB / 6°C WB, entering air temperature: 20°C.
Performance condition 3 - Air: 35°C DB, entering air temperature: 28°C.
Heating capacity
COP
Heating capacity
COP
Cooling capacity
EER
Dimension
Net / Gross weight (Indoor unit)
Net / Gross weight (Outdoor unit)
Unit (W×D×H)
Packing (W×D×H)
R410A / EXV
Φ6.35 / Φ9.52
DC with EVI / Brushless DC
42 (Indoor) / 52 (Outdoor)
698×207×599 (Indoor unit); 792×300×550 (Outdoor unit)
790×292×726 (Indoor unit); 907×400×604 (Outdoor unit)
15 / 19
RFC-40W/BPh-A
2.05
4.00
4.12
3.28
3.80
Heating: -30°C - 27°C; Cooling: 18°C - 43°C
4.00
R410A / EXV
Φ6.35 / Φ9.52
DC with EVI / Brushless DC
42 (Indoor) / 54 (Outdoor)
15 / 19
34 / 40
220~, 1Ph, 50Hz 220~, 1Ph, 50Hz
31 / 36
Refrigerant type / Control
Power supply
Connection refrigerant pipes
Compressor / Fan motor
Sound pressure level
Console H/PConsole H/P
Recommended