- B t n r
Pollutants DENR-EMB Standard
o og ca xygen eman
(BOD)
mg
Chemical Oxygen Demand
COD
100 mg/l
Total Suspended Solids
(TSS)
70 mg/l
Color 150
Oil & Grease 5 mg/l
pH 6.5 9.0
7/28/2019 Green Initiative Brochure v5
4/18
l n t r tThe Philippine Clean Water Act of 2004 (Republic Act No. 9275aims to protect the countrys water bodies from pollution from
-
agriculture and community/household activities).
How will discharges of wastewater be controlled?
are required to get a permit to discharge from the DENR or the
Laguna Lake Development Authority.
How will the discharge of wastewater be discouraged?
Anyone discharging wastewater into a water body will have to
pay a wastewater charge.
What are the prohibited acts under The Clean Water Act?
Among others, the Act prohibits the following:
1. Discharging or depositing any water pollutant to the water
body.
2. Discharging, injecting or allowing to enter into the soil,
anyt ing t at wou po ute groun water.
3. Operating facilities that discharge regulated water pollutants
without the valid required permits.
7/28/2019 Green Initiative Brochure v5
5/18
Pr h t tAmong others, the Act prohibits the following:
.
body.
2. Discharging, injecting or allowing to enter into the soil,
anything that would pollute groundwater.
3. O eratin facilities that dischar e re ulated water ollutants
without the valid required permits.
4. Unauthorized transport or dumping into waters of sewage
sludge or solid waste.
5. Refusal to allow entry, inspection and monitoring as well as
access to reports and records by the DENR.
6. Refusal or failure to submit reports and/or designate
pollution control officers whenever required by the DENR.7. Disposal of potentially infectious medical waste into sea by
vessels.
8. Operate facilities that discharge or allow to seep, willfully or
through grave negligence, prohibited chemicals, substances,
or pollutants into water bodies.
7/28/2019 Green Initiative Brochure v5
6/18
n n P n lt
1st Offense: Upon the recommendation of the Pollution
Adjudication Board (PAB), anyone who commits prohibited act
such as discharging untreated wastewater into any water bod
will be fined for every day of violation, the amount of not les
than Php 10,000 but not more than Php 200,000.
2n Offense: Failure to undertake clean-up operations willfullyshall be punished by imprisonment of not less than two year
and not more than four years. This also includes a fine of no
less than Php 50,000 and not more than Php 100,000 per day o
v o a on.
3rd Offense: Failure or refusal to clean up which results in seriou
injury or loss of life or lead to irreversible water contamination o
, ,
imprisonment of not less than 6 years and 1 day and not mor
than 12 years and a fine of Php 500,000/day for each day the
contamination or omission continues.
7/28/2019 Green Initiative Brochure v5
7/18
Compliance
an o u ons-PACKEDMEDIATECHNOLOGY (RBC-PMT)
7/28/2019 Green Initiative Brochure v5
8/18
h t B . . .Rotating Biological Contactors, commonly called RBCs, are used inwastewater treatment plants (WWTPs). The primary function of these
bio-reactors at WWTPs is the reduction organic matter.
Design
A suspended/fixed growth biological treatment processes used to
consume organic matter (BOD) from wastewater.
ons s s o - m ame er s s, c ose y space on a ro a nghorizontal axis.
Disks are covered with a biofilm.
The disks are only partially submerged in wastewater.
As the disk rotates, the biofilm is exposed to the wastewater only
part of the time.
The rotation in and out of the wastewater serves to vary the feeding
cycle (starve/gorge) of the bacteria and microorganisms that make
up the biofilm.
The shaft rotates about 1-2 r m slowl .
Some advantages: Less Upset, High Loading Rate, Nitrification/De-
nitrification, Low O&M Cost, Durable Constructions, Odorless, No
Noise.
7/28/2019 Green Initiative Brochure v5
9/18
H w t w rkRBC Package Plants
Three separate processes (primary settlement, bio-contactor and fina
clarification) are combined in a single tank enclosed by low-profil
covers. T e integra primary tan co ects an stores screenings an
detritus and provides 90 days sludge storage to remove the need fo
separate on-site facilities, thus reducing capital and operational costs.
RBC Package Plants are generally supplied for small and medium
populations; where populations are large, multiple units can be used i
parallel.
Modular RBCs
Generally used for large populations, in a modular system in both primar
zone. Using individual tanks for each of the three unit processes provide
the greatest flexibility in process design and site layout. The Primar
section may be either a sealed septic or a conical upward flow settlementank. Biological treatment takes place in the self-contained Bio-Contacto
w c may e nsta e n e t er a or concrete tan . na sett emen
occurs in an upward flow clarifier.
7/28/2019 Green Initiative Brochure v5
10/18
Operation &
Operating a stand alone facility like our treatment system bring
a lot of challen e. Normall most desi ners are not re ared to
Maintenance
do it or sometimes are faced with very costly prospects to have i
done "in-house". With these considerations in mind, we offe
our services to operate and maintain the treatment facilities tha
we have installed. Our years of experience give us the edge and
confidence to operate and provide the best treatment for youspecific wastewater issues. We are sharing this confidence with
you as we build mutual trust and partnerships to clean ou
environment. Indeed, it is our pride to be operating a system
which is truly our own - a Filipino ingenuity.
Henceforth, sustaining our technology's operation, operating andmaintaining it will be our commitment to you. However, ou
c ents may c oose to operate t e system t emse ves or re ou
services to do the dirty job of handling their wastewater. In the
services (as applied to individual and common installations) tha
we offer, we also see to it that our clients are able to mee
.
believe that the mark of a truly efficient system is when it passe
regulatory standards without having to pretend. We look forward
to this partnership with you.
7/28/2019 Green Initiative Brochure v5
11/18
Principles of
DISCS
C-PM
some light synthetic material (Amazon screen) will
keep on rotating via the horizontal axis at a rather
slow speed (1.5 rpm) inside a wastewater
treatment tank.
BIOMASS
A microbial film or a layer of sludge that will
digest all the organic pollutants during the
rocess and de rade it biolo icall .
The upper half of the rotating disc will haveBREATHING-PHASE
take up oxygen so that the BIOMASS will exist
and the biological degradation of the organic
pollutants inside the wastewater will take place.
While the lower half of the rotating discs is half
submerged to the wastewater to take up organic
pollutants in order to undergo the treatment
EATING-PHASE
process.
7/28/2019 Green Initiative Brochure v5
12/18
Why Choose-
Features Benefits
oca ze par s an ma er a s
for RBC
ow e ec ve cos an
affordable
Few moving parts Easy and low maintenance
Few pumps and motor Low power consumption
Close loop Minimal disposal of sludge
Fiber Reinforced Plastic (FRP) Low maintenance cost
Movable and lightweight FRP Flexible use of space
No chemical additive Low operational cost
Possible water re-use Savings from consumption
Modular Lower ex ansion and retrofit
costs
7/28/2019 Green Initiative Brochure v5
13/18
Standard
1. Rotating Shaft : 2.0 inches Stainless Stee
pec ca ons
2. Media Packs : Amazon Screen
3. Treatment Capacity : 75-100 cu.m
4. Treatment Efficacy : up to 95%
5. Minimum Space Required : 2.5m x 6.5m
. e g : e ow ons7. Diameter : 1.8m
8. Tank Dimension : 2.2m x 4.5m x 1.6m
9. Rotation Speed : 1.5 rpm
. ,
11. Power Consumption : 3 HP/module
12. Overhead Tank Capacity : 4 cu.m. capacity with
metal stand support on th
1. Clarifier Capacity : 2 cu.m.
2. Plastic Media Material : Plastic Screen
3. WWTP Tank : Fiber Reinforced Plastic
(FRP) with cover and meta
cradle4. Flow Rate : 3 cu.m. per hour
7/28/2019 Green Initiative Brochure v5
14/18
7/28/2019 Green Initiative Brochure v5
15/18
7/28/2019 Green Initiative Brochure v5
16/18
Success Stories
Metro San Jose Medical Center
situated in San Jose,
Batangas City
Packed Media Technology (RBC-PMT)
Date installed : September 2002
Volume : 75 cu.m. per day.
St. Vincent HospitalCebu City
Toyota Service CenterCebu City
7/28/2019 Green Initiative Brochure v5
17/18
Success Stories
Lapu-Lapu City, Cebu
10 units of Rotating Biological Contactor
Packed Media Technology (RBC-PMT)
Servicing Three(3) Barangays in Lapu-Lapu City,
Province of Cebu
Robinland Condominium Phil Export Zone Authority,Cebu City Head Office - Cebu City
7/28/2019 Green Initiative Brochure v5
18/18
Contact us
GREEN INITIATIVE ECOSERVICES CORP.
31 Lopez Jaena St., Brgy. Taong
Marikina City Philippines 1803
Tel. No: 654 3266
o e os: -
0933-4744346
Email: info@green-initiative.com
www.green-initiative.com.ph
Recommended