GNT400 - datasheet.octopart.com

Preview:

Citation preview

GNT400Front End Series 400 Watt AC/DC

Universal Input Power Supply

InputVoltageRange Universalinput,80-270VAC(Seenote).

InputFrequency 45-65Hz

InputCurrent 120VAC,4.2A.230VAC,2.1A.

InrushCurrent Activecircuit,37Amax.peak.

InputFuse F1,F2,6.3Aforlineandneutral.

PowerFactor 0.99typical,0.96minimum.

EarthLeakageCurrent 100µAat120Vac,60HzNormal.400µAat264V,50HzSinglefault.

OutputPower 400Wwithfancooling.Seederatingchartforotherconditions.

PeakOutputPower 450Wfor1minute,10%dutycycle.

OutputVoltage Seechart.

VoltageAdjustability +/-5%minimum.

MinimumLoad Notrequired.

TotalRegulation Seechart.

• Compact 4” x 7” x 1.5” U Channel (1U Compatible) • 9.5 W/in3 • 100-240 VAC Input with Active PFC • 12 to 48 V DC Output at 400 W • 5 Vdc 100 mA Standby Output • 12 V DC Fan Output • Approved to UL, CSA and EN/IEC Standards • 300 W Convection Rating • Less than 100 μA Leakage • Compliance to EN55011/22 Conducted Noise B • RoHS Compliant-Category 6

2 Year Warranty

TransientResponse 500µsto1%,0.2A/µs,3.5%for50%steploadchange.

TurnOnTime 500msmax.

Hold-upTime 20msat400W.

Over/Undershoot 3.5%max.

OverloadProtection Cyclingtype,470Wtypical.

OvervoltageProtection Seechart.

RippleandNoise 1%pk-pkmax.,20MHzBW.

RemoteSense Compensatesforupto500mV.

CommercialSafetyStandards UL/EN/CSA60950-1.

MedicalSafetyStandards UL/EN/IEC60601-1

ThermalConsiderations Component RecommendedMax.Temperature T5coverindentation 90°C T1Insidecoil 100°C

SwitchingFrequency Output170kHz+/-8kHz.PFC140kHz+/-8kHz.

Specifications All specifications are typical at nominal input, full load at 25°C unless otherwise stated

The GNT400 provides 400 W of DC output power in a compact package. Standby, control and monitoring inputs and outputs provide all the essential elements for a variety of applications including, single board computers, running motors, pumps, and solenoids. Approval to EN60601-1 and EN60950 improves design-in time and reduces end system compliance costs.

SL Power Electronics Corp. • 6050 King Drive • Ventura, CA 93003 • Phone:805.486.4565 • Fax:805.487.8911 • Email:info@slpower.com • www.slpower.com

GNT400Front End Series 400 Watt AC/DC

Universal Input Power Supply

Model Volts FanCooled Convection Ripple Total OVP Number Amps Amps &Noise Regulation Threshold

GNT412ABG 12V 33.3A 25A 120mV +/-2% 14V+/-0.75V

GNT424ABG 24V 16.7A 12.5A 240mV +/-2% 26.5V+/-1V

GNT436ABG 36V 11.1A 8.3A 360mV +/-2% 39V+/-1V

GNT448ABG 48V 8.4A 6.3A 480mV +/-2% 55V+/-2V

MTBF 300KhoursperTelcordia.

OvertemperatureProtection Automatic.

Efficiency typical88%@120VAC,91%@240.

Signals PSOn-LowtoInhibit. PSOff-TTLHitoInhibit. PwrOK-HiwhenACisOK100-200msdelay. PwrOK-PFLow4mswarning. DCOK-Hiwhenoutputis>95%.

FanOutput 12Vdc@250mA(turnsoffduringInhibit).

5VStandbyVoltage Alwayson,upto100mA.

EMC/EMIInformation ConductedEmissions EN55011/22 ClassB RadiatedEmissions EN55011/22 ClassA Linefreq.Harmonics EN61000-3-2 ClassA VoltageFluctuations EN61000-3-3 Complies ESD EN61000-4-2 Cont.6kV,Air8kV RadiatedImmunity EN61000-4-3 3V/m FastTransients(EFT) EN61000-4-4 2kV5kHz LineSurgeImmunity EN61000-4-5 2kVCM,1kVDif. ConductedImmunity EN61000-4-6 3Vrms PowerFreq.Mag.Field EN61000-4-8 3A/m VoltageDipImmunity EN61000-4-11 ContactFactory

GeneralSpecifications(continuedfromp.1)

1.Whentheinputvoltageis<90Vac,derateoutputpowerto300Wfancooledor250Wconvection. 2.UsingEorTcoveroptionsallowsfor400Wcontinuousoperationupto40°C. 3.For400W@50°C,use100Ifmfancooling.

Note

OperatingTemperature 0to70°C(seechart).

StorageTemperature -40to+85°C.

OperatingAltitude -500to10,000ft.

Non-operatingAltitude -500to40,000ft.

RelativeHumidity 5%-95%.

Vibration 5Hz-500Hz,2.5grms.

Shock MIL-STD-810E,516.4partIV.

EnvironmentalSpecifications

2 of 4

SL Power Electronics Corp. • 6050 King Drive • Ventura, CA 93003 • Phone:805.486.4565 • Fax:805.487.8911 • Email:info@slpower.com • www.slpower.com

OutputPowerDeratingCurve

0

50

100

150

200

250

300

350

400

450

0 10 20 30 40 50 60 70

Degrees C

Ou

tpu

t P

ow

er (

Wat

ts)

Fan Cooled

Convection Cooled

GNT400Front End Series 400 Watt AC/DC

Universal Input Power Supply

3 of 4

SL Power Electronics Corp. • 6050 King Drive • Ventura, CA 93003 • Phone:805.486.4565 • Fax:805.487.8911 • Email:info@slpower.com • www.slpower.com

MountingOptions

Mating Connectors (Tyco/Amp)Location Option TypeInput A #6-32 Lug .325 CTR

B WireC Amp 640250-5 and 3-770476-1

Output B #10-32 LugT Wire

J3 Amp 64xxxx-8 with socketsJ Fan Amp 64xxxx-2 with sockets

GNT400Front End Series 400 Watt AC/DC

Universal Input Power Supply

SL Power Electronics Corp. • 6050 King Drive • Ventura, CA 93003 • Phone:805.486.4565 • Fax:805.487.8911 • Email:info@slpower.com • www.slpower.comDataSheet©2007SLPowerElectronicsCorp.Theinformationandspecificationscontainedinthisdatasheetarebelievedtobecorrectattimeofpublication.However,SLPoweracceptsnoresponsibilityforconsequencesarisingfromreproductionerrorsorinaccuracies.Specificationsaresubjecttochangewithoutnotice.Rev.04/18/07

4 of 4

MountingOptions(continuedfromp.3)

Recommended