View
359
Download
14
Category
Preview:
Citation preview
. . . s i n c e 1 9 6 3
g e n e r a lc a t a l o g u e
e q u i p m e n t a n d s y s t e m s f o r a i r c o n d i t i o n i n g
3RC GROUP SpA • General Catalogue • 155.EN.0504
Soluzioni Affidabiliper
Applicazioni CriticheGeneral Index
INTRODUCTION 4
COMPANY PRESENTATION 10
REFERENCES 18
Over 22
Under 36
Displacement 52
Flexiclim System 60
Heat Pumps 66
Over 72
Displacement 80
Air cooled 88
Free-Cooling 138
Heat pumps 172
Multifunction 218
Water cooled 236
Evaporating units 254
Heat pump evaporating units 268
LIQUID CHILLERS IN 134a VERSION 274
AIR COOLED CONDENSERS AND DRY COOLERS 290
AIR CONDITIONERS FOR HI-TECH.AND COMFORT APPLICATIONS
AIR CONDITIONERS FORINFORMATION TECHNOLOGYAND COMMUNICATION
LIQUID CHILLERS
4 RC GROUP SpA • General Catalogue • 155.EN.0504
Introduction
INFORMATION TECHNOLOGY
MOBILE COMMUNICATION
TELECOMMUNICATION
BANKS & HI - TECH. OFFICES
INDUSTRIAL PROCESSES
The products described throughout this catalogue are the offspring ofa 40-year experience in designing and building of air conditioning units andliquid chillers.
Our production quality is guaranteed by the use of high reliability com-ponents and by continuous investments allowing our company to make useof the most advanced technologies.
The commitment in research and in our organisation grants a continu-ous growth of our products to meet the users’ requirements.
Company professional competence lets us offer each customer a mostqualified and considerable business relation.
The images here displayed generally summarize the different applica-tions to which our products are dedicated, starting from: Hi-Tech. to Com-fort applications, passing through Industry and Leisure.
Every application is characterized by precise working and plant logicsand all of them are joined by the one and only fundamental problems: theapplication criticality.
Critical Applications are defined by their requirement of which full “Con-tinuity & Quality” of service are not seen as optional but are demanded asfundamental to the service itself.
These applications normally operate 24 hours a day, 7 days a week, 12months a year.
They range from vital services supported by sophisticated electronicsystems, through installations providing information to the business com-munity and general public amenities designed to improve the quality of ourday to day lives.
Most of today’s products available on the market, especially waterchillers for support of room air conditioning units are designed and manu-factured to be used for Comfort Cooling applications, requiring only sea-sonal cooling during the summer period. Failure of these systems resultsonly in minimal personal discomfort to the occupants.
RC product range is specifically designed and manufactured to meetthe most demanding requirements of the Critical Application Project type interms of 24 hour a day, all year round operation, energy efficiency andbuilt-in redundancies.
RC equipment production has always been directed towards air condi-tioning and liquid refrigeration systems for applications with high criticalcontent. The first units manufactured in 1963, were in fact 3 Close ControlCabinet Units for the computing department of a Bank. Since then RC hasdeveloped significant expertise both in the system evaluation, equipmentmanufacture and in the research of suitable and innovative solutions. Thisexperience has contributed to a continuous improvement of the product ofwhich this issue of the RC Catalogue is the summary.
Technology, absolute reliability, high quality and the corresponding ex-acting attention to the various system requirements are the main ingredi-ents of the proposed wide product range.
5RC GROUP SpA • General Catalogue • 155.EN.0504
Soluzioni Affidabiliper
Applicazioni CriticheIntroduction
LEISURE AND ENTERTAINEMENT
SHOPPING CENTRES
TRANSPORT
HOSPITALS
SMALL OFFICES & HOME
The commitment of RC finds a reply in the thousands of product deliv-eries, destined to these types of installations. These particular applica-tions need reliable equipment in order to guarantee uninterrupted work-ing and to reduce the technical assistance required for routine mainte-nance procedures.
RC uses this design and manufacturing normally and generally; the prod-uct, specific for critical applications, is strictly mass-produced to ensurerepeatable high quality products as shown in the RC catalogues.
RC has always been at the leading edge of applied research and thenew technologies to improve its production capabilities.
This enterprise policy has given important results, further promotingRC products as a market leader on the international stage together withan International Worldwide Sales and After-Sales Network. Competent andalways well-informed engineers are always available to give current prod-uct and system application advice, best suited to the Client’s specific projectrequirements.
RC progressive sales network covers the whole world in an extensiveway. This network is supported by a widespread and qualified ServiceOrganization that guarantees an excellent after-sales service with reac-tion times corresponding only to the importance of that demanded by theClient’s service requirements.
The confirmation of RC continuing product quality is the systematicdevelopment of its products, in the applications where the system reliabil-ity is a priority.
To allow a simple use of this catalogue we have divided the whole pro-duction following the already tested logic applied to the company Internetsite www.rcgroup.it.
This partition helps to identify a specific product in a simple and intui-tive way.
A range of “plus point” (short descriptions reporting particular char-acteristics) supported by detailed images highlights the product particu-lar characteristics. The “plus point” are not strictly bound to the product,but they highlight the characteristics of a whole range; basically they arecontained throughout the pages detailing the specific product series.
The so highlighted Plus Points and with “®” symbol identify a RC GROUPinternational PATENT.
In the following pages we summarize the entire manufacturing and theplus contained in the catalogue, identifying them with a short description.
6 RC GROUP SpA • General Catalogue • 155.EN.0504
Plus Points List
PLUS POINTS
3SpeedAdaptiveRange
Air-Rail®ColdLayerCool4Free
CoolingDensityPlusDBelt
DirectControlDirectCool
DisplacementDNA@RC
Easy@ServEasyFit
EasyLinkEfficientFlow
EMCExtraCircuit
FastHeatFlexiBox
Flexiclim®ForcedDehumidification
HeatPackageHoneyCombMade2Last
MateMistral®
MP.COMNoiseControl
PerformancePlusProHumid
PureAirQuickStart
RCProactiveSave
ServiceFastSideBySide
SleepWellSmartLink
SolutionSpaceSaver
SynergyTopRate
TwinPowerVCoil
WindowMateYRFan
Description of “Plus Points” related to AIR CONDITIONING UNITS
3 speed air treatment fansIt satisfies every plant needsPatended induction system on displacement air deliveryProprietary RC technology for displacement air delivery optimizationIndirect Free-Cooling for units with built-in water condensing systemThe best ratio between occupied space and cooling capacityBelt drive system for air treatment fansProportional humidifier controlled by the microprocessorDirect Free-Cooling with proportional damperDisplacement air deliveryBig precision air conditioners technology shifted to small unitsAir filters removal from the front of the unit without opening any panelEasy to reposition or extend without technicians interventionKit for air suction and outdoor exhaustionFans speed regulation for displacement air deliveryElectromagnetic suitabilitySystem for available energy employment, or for an integrated backupLow thermal inertia electric heating system, with no ionization on airNoiseless terminal units with no maintenance needPatented Flexiclim SystemDehumidification without air flow modificationsHot water heating with 3 way valveOptimized air distribution grille for displacement air deliveryHousing designed to last in time and in bad weatherCondensing control system with speed modulation of condensers fansPatended control logic for displacement air delivery systemsThe new RC microprocessors generationNoise deading cups for compressors noise reductionTandem SCROLL type compressorsElectronic controlled proportional humidifierFlexible ducting for terminal units connectionEasy and quick unit start-upContinuity of work even in emergency situationsAir treatment fans speed modulation according to the loadStandard maintenance with the unit in working modeSerial installation to obtain high cooling capacities in reduced spaceLowest noise emission during the nightLAN network with no additional componentsMaximum energy saving with Heat Hunter units and Optimizer systemInspection and maintenance operations from the front of the unitSynergy within displacement units and traditional onesMaximum energy saving for each chilled water unitDouble electric feeding“V” shaped cooling coilsUnder window installationDirect or belt drive ventilation systems
7RC GROUP SpA • General Catalogue • 155.EN.0504
Soluzioni Affidabiliper
Applicazioni CritichePlus Points List
PLUS POINTS
4in40AdaptiveRangeAntirumbleBufferTankCentriCoolingDensityPlusDNA@RCDual®Easy@ServEMCFreezeProtectionFullHeatReclaim (FHR)Gamma ELN (Super Silent)GlycolFreeIDEA®Idrocompl®KeepCoolIdronicPackMade2LastMateMaximo&DualMP.COMMP99MyNoiseNoFreezeNoiseBoxOptimizer®PerformancePlusPump&PressurePumpStationQuickStartRCProactiveSCR&MP99ScrewScrollServiceFastSideBySideSleepWellSpaceSaverTR88Zytel
Description of “Plus Points” related to LIQUID CHILLERS
4 units in a 40 feet containerIt satisfies every plant needsAnti rumble rigid base frame
Water buffer tankCentrifugal fan unit version for indoor and/or ducted installations
The best ratio between occupied space and cooling capacityBig precision liquid chillers technology shifted to small units
The most powerful reciprocating compressor in the worldAccess to all components through comfortable frontal panels
Electromagnetic suitabilityEvaporator anti-freeze protection controlled by the microprocessor
Integrated system for total condensing heat reclaimTotal product redesign to minimize the noise emissions
Free-Cooling integrated system with no need of antifreezingPatented defrosting system with dynamic scanning of working parameters
Patented evaporator, expansion and water tank in a sole casingWorking continuity with high outdoor temperatures
Pump and tank in a sole package without plan measurements increaseHousing designed to last in time and in bad weather
Condensing control system with speed modulation of condensers fansFree-Cooling packaged liquid chillers up to 1.610 kW
The new RC microprocessors generation with AUTOADAPTIVE logicMicroprocessor system equipped with RC PROACTIVE proprietary logic
Range of solutions to control the noise emissionsAntifreeze system preventing the water in the evaporator from freezing
Compressors acoustic deading systemPatented system for variable water flow plants
Tandem SCROLL type compressors to grant the maximum energy efficiencyCirculation pump with water plant pressure control
Pump station inside the unit with no size increaseEasy and quick unit start-up
Continuity of work even in emergency situationsSCR system optimizing total and patial Free-Cooling cyclesDouble screw helicoidal compressors with high efficiency
The most modern technology in the field of medium/small compressors sizeStandard maintenance with the unit in working mode
Serial installation to obtain high cooling capacities in reduced spaceLowest noise emission during the night
Inspection and maintenance operations from the front of the unitSupervision and remote control system; up to 8 unità
Air delivery pipes made of patented plastic material
8 RC GROUP SpA • General Catalogue • 155.EN.0504
Plus Points List
AIR CONDITIONERS AIR CONDITIONERS FORINFORMATION TECHNOLOGY
AND COMMUNICATION
CONS
OLE O
VER
PEGA
SUS
OVER
COM
PACT
OVE
RCO
NSOL
E UND
ERPE
GASU
S UN
DER
COM
PACT
UND
ERHA
ET H
UNTE
RFL
EXIC
LIM O
VER
FLEX
ICLIM
UND
ERPE
GASU
S OV
ER H
P
MIN
IPAC
OVER
ENER
TEL O
VER
EBER
GY S
PLIT
OVE
REN
ERTE
L DL
PEGA
SUS
DL
3Speed • • • • • • • • •AdaptiveRange • • • • • • • • • • • • • • •
Air-Rail® •ColdLayer •
Autoadaptive •Cool4Free • •
CoolingDensityPlus • • • • • • • • • • • • • • •DBelt • • • • •
DirectControl • • • • • • • • • •DirectCool • • • • • •
Displacement • • •DNA@RC • •
Easy@Serv • • •EasyFit • •
EasyLink • • •EfficientFlow •
EMC • • • • • • • • • • • • • • •ExtraCircuit • •
FastHeat • • • • • • • • • • • • • • •FlexiBox • •
Flexiclim® • •ForcedDehumidification • • • • • • • • •
HeatPackage • • • • • • • • •HoneyComb •Made2Last • • • • • • • • • • • • • • •
Mate • • • • • • • • • • •Mistral® •
MP.COM •NoiseControl • • •
PerformancePlus • • •ProHumid • • • • • • • • • •
PureAir • •QuickStart • • • • • • • • • • • • • • •
RCProactive • • • • • • • • • • • • • • •Save • • • • • •
ServiceFast • • • • • • • • • • • • • • •SideBySide •
SleepWell • • • • •SmartLink • • • • • • • • • • • • • • •
Solution •SpaceSaver • • • • • • • • • • • • • • •
Synergy •TopRate • • • • • • • • • •
TwinPower • • • • •VCoil • •
WindowMate • •YRFan • • •
9RC GROUP SpA • General Catalogue • 155.EN.0504
Soluzioni Affidabiliper
Applicazioni CritichePlus Points List
LIQUID CHILLERS
AIR COOLED WATER COOLED
EASY
CILL
I.IDR
OCOM
PLUN
ICO
MOD
ULO
MAX
IMO
EASY
.PCI
LLI.I
DROC
OMPL
.PRE
VERS
O.P
MOD
ULO.
PM
ULTI
PLO
AQUA
.IDRO
COM
PLCO
DLPA
CKFR
IGO
DIVI
.IDRO
COM
PL.P
TEAM
.MAT
E
• • 4in40• • • • • • • • • • • • • • • AdaptiveRange• • • • • • Antirumble• • • • • • • • • • BufferTank
• • • • • • • Centri• • • • • • • • • • • • • • • CoolingDensityPlus• • • • • • • DNA@RC
• • • • • • Dual®• • • • • • • • • • • Easy@Serv• • • • • • • • • • • • • • • EMC• • • • • • • • • • • • • • FreezeProtection
• • • • FullHeatReclaim (FHR)• • • • • Gamma ELN
• GlycolFree• • • • • • IDEA®
• • • • Idrocompl®• KeepCool• • • • • • IdronicPack• • • • • • • • • • • • • • • Made2Last• • • • • • • • • • • Mate
• Maximo&Dual• • • MP.COM
• • • • • • • MP99• • • • • • • • MyNoise
• • • • • • • • • • • • • • NoFreeze• • • • NoiseBox
• Optimizer®• • • • • • • • • • • • PerformancePlus• • • • • • Pump&Pressure
• • • • • • PumpStation• • • • • • • • • • • • • • • QuickStart• • • • • • • • • • • • • • RCProactive
• SCR&MP99• • • • Screw
• • • • • • • • • • • • Scroll• • • • • • • • • • • • • • • ServiceFast
• • SideBySide• SleepWell
• • • • • • • • • • • • • • • SpaceSaver• • • • • • • TR88• • • • • Zytel
10 RC GROUP SpA • General Catalogue • 155.EN.0504
Freely taken from the article which appeared in “CDA-Condizionamento dell’AriaRiscaldamento Refrigerazione” of November 1999.
Almost all the entrepreneurial realities, which we have had the opportu-nity to become acquainted with on the occasion of our interviews, have incommon determination and initiative, qualities which put the Italian workworld in a positive light even though it is still so controversial and tor-mented.Every company, however, has its own peculiarities that can be discoveredduring interviews or felt in the air having just crossed the threshold.In the case of RC Group the first sensation was one of serenity, or better, ofefficiency without agitation. Tranquil its location at the foot of the Pavesehills, inviting its headquarters, serene the attitude of its office workersand factory workers, neat and tidy its plant. The activity is intense but, aswe will see, governed by organization and common sense.Roberto Caciolli, who gave us the interview, is one of the three owners, allin the management of the company, together with his brother Fabrizio andtheir friend Sergio Gallina.
History always helps us to understand the present and in the evolution ofyour Group, I believe it is almost indispensable to know the beginnings.The Company was established in 1963 with the aim of producing air conditioningand refrigeration systems for critical applications. One of the first products wasan air conditioner for a data processing centre for San Paolo Bank of Torino(probably one of the first air conditioner for data processing centres realized inItaly).
This typology required a lot of know-how at all levels, from the knowledgeof the problem to solve to the ability to choose the most appropriate tech-nological applications.Throughout the sixties the company grew slowly, without a real array ofproducts for mass-production, but producing on order what the marketrequired of the refrigeration and conditioning of the times, designing andrealizing personalized machines on the basis of the customer’s needs.The experience of those first years in its life profoundly influenced thecompany philosophy, making flexibility and speed of response to the marketneeds the cards which are still winning today.A first turn took place at the beginning of the seventies when we presenteda line of air conditioners especially dedicated to DPC and an agreement wassigned with a Multinational Leader in the computer field that wanted tooffer turnkey solutions to its clients.Not only the computer part was offered, but also all the equipment for thesite and whatever was necessary for the correct functioning of the ma-chines contained in it.
1963 1970 1980
The Company was estabilished in 1963with the aim of producing air condition-ing and refrigeration systems for criti-cal applications.The experience of those first years inits life profoundly influenced the com-pany philosophy, making flexibility andspeed of response to the market needsthe cards which are still winning today.
Company presentation
1963the first air conditioner for data processing centres
11RC GROUP SpA • General Catalogue • 155.EN.0504
Soluzioni Affidabiliper
Applicazioni Critiche
The agreement permitted RC Condizionatori to consolidate and presentingitself at the beginning of the eighties on the European market with a well-defined catalogue of specific products for DPC.In 1982 we created a distribution network, covering initially all of westernEurope with remarkable success right from the beginning, because in thatmoment the companies in the market were very few. It was a rapidly-growing market, with a high technological component, suitable for smalland medium-sized companies, rapid and flexible, that made it possible torealize extremely interesting economic results.The profits in this way were constantly reinvested, permitting the com-pany to multiply its proceeds of sales every year from 1978 to 1989, al-ways maintaining unchanged the quality of its products, of the service of-fered to its clients and of the company organization.
In the years immediately following there was a great crisis in the EDP field;did your orientation change?After 1989 the processing understood as a central unit of data processingdisappeared, that “big black box” which needed to be maintained underspecial predefined conditions by a special air conditioning system con-structed ad hoc. With the development of distributed computer systems and of the per-sonal computer, the market for conditioners for DPC dropped vertically.We had already prepared for this situation: already towards the end of1988 we had started pushing more for the refrigeration for civil air condi-tioning which, in any case, already represented an important part of ourproduction (about 20% of our proceeds of sales).Towards the end of 1989 we acquired a company in Rome, the AMP, special-ized in the construction of big size water chillers and of an array of recip-rocating compressors with specific capacities from 200 to 500 kW.These two realities fused in November 1998 giving life to the RC Group.Between the end of the eighties and the beginning of the nineties we var-ied our mix of products a great deal: at the end of the last decade about80% of our production was aimed at data processing centres and about20% at refrigeration for air conditioning in the advanced tertiary, butalready in 1991-1992 the proportion had changed its course reaching aratio of 40% to 60%.This permitted us to maintain a constant growth and to have sufficientresources to transfer immediately to the emerging field of digital and cel-lular telephony, first, and of advanced computer systems today (technolo-gies connected to the transmission, elaboration and storage of data withInternet Protocol), all experience acquired in the systems for DPC.The results attained in these areas brought us to such an increase in pro-ceeds of sales that, even facing a continual increase in the field of refrig-eration for civil uses and for the tertiary, the mix returned to a net pre-dominance of products with a high technological content.At the present time, in the field of telecommunication, mobile phones andadvanced computer systems we cover a very interesting quota of themarket, both in Italy and worldwide where, if we exclude the United States,we are one of the two leading companies with worldwide coverage.In 1992, again with the aim of diversifying the production, a new evapora-tor was immediately studied and patented which incorporates a system ofaccumulation and expansion tank and filling called Idrocompl.
DUAL compressor at 10 cylinderscooling capacity 500kW
RC Group commercial department
Towards the end of 1989 we acquired acompany in Rome, the AMP, specializedin the construction of big size waterchillers and of an array of reciprocat-ing compressors with specific capaci-ties from 200 to 500kW.
Company presentation
12 RC GROUP SpA • General Catalogue • 155.EN.0504
This component has become the starting point for the engineering of a newline of chillers with low capacity (7÷80kW) with innovative characteris-tics compared to the competition.Idrocompl boasts, in fact, a characteristic that makes it unique: it is abso-lutely resistant to the formation of ice on the inside, generated by wrongmanoeuvres or breakdown of the security devices.Since 2002 there have therefore been two productive poles, each with itsown philosophy at the product level:• AMP in Rome is the company that produces both the chillers with high
capacity (from 400 to 4000 kW) and a series of reciprocating compres-sors from 3 to 10 cylinders (presently the most powerful in the worldconstructed);
• RC Condizionatori in Pavia produces the middle range in the array of chill-ers (from 50 to 400 kW) and, in addition to that, is specialized in the partof air conditioning for telecommunication and for technological premisesof medium and large capacity and in the systems of air conditioning formobile communication;
• RC Condizionatori in Zeccone is specialized in small chillers (5÷270kW).Our productive growth over the nineties was therefore remarkable.
Consequently, the effort for organization to cover the various market ar-eas will also have been remarkable.
Yes, today our company is well represented throughout Italy with anetwork of Agents who are supported in turn by a network of technicalpost-sales service, even more vast and capillary. Abroad, instead, we workwith exclusive Distributors, companies which handle both the commerciali-zation of the product and the technical service.
Technical service is one of our favourite points: in our market of refer-ence, the technological field, machines must work 24 hours a day for 365days a year, so post-sales service is a key factor in the correct functioningof the system.
With the same philosophy we face also the civil and tertiary field, andso our authorized Service Centres are able to respond rapidly even in themost critical periods of the year.
How is this tissue of single realities managed? Centrally by the RC Group,or also by Rome?
At organizational level, the two divisions are maintained completelyindependent and are considered to be autonomous profit centres at pro-duction level, though they were fused in 1998 into a single legal entity,the RC Group. Research & Development, Commercial and Financial activi-ties are centralized. Centralized but not from a geographic standpoint,
Patented IDROCOMPL system
... our company is well representedthroughout Italy with a network ofAgents who are supported in turn by anetwork of technical post-sales service,even more vast and capillary.Abroad, instead, we work with exclu-sive Distributors, companies which han-dle both the commercialization of theproduct and the technical service.
Big Size Chiller assembly line
Company presentation
13RC GROUP SpA • General Catalogue • 155.EN.0504
Soluzioni Affidabiliper
Applicazioni Critiche
since the technical, commercial and financial personnel is distributedamong the two structures and cooperate through an advanced commu-nication system, allowing sharing of projects, data, images and docu-ments in real time.
What are the pros and cons of this organization of sales based on Distribu-tors?
The Distributor is a choice we made at the beginning and one we be-lieve in and will carry on with. On the one hand it becomes challenging interms of management because there are three independent companiesworking with their own objectives and their own mode of being present onthe market. But, on the other hand, they guarantee a strong motivation forreaching volumes of sales increasingly more interesting.
In addition to that, a high and efficient exchange of information is real-ized without any type of filter: the more the Distributors are able to trans-fer their market problems to us, the more we are able to solve them cre-ating in this way objectives in common and a virtuous circle.
The mutual satisfaction of this system is confirmed by the fact that theturnover of our distributors is very low: 80% of those activated in 1983are still operating.
Also the turnover on the inside of our Group is low, perhaps thanks tothe fact the Company has always followed very precise procedures, bothat the commercial and industrial levels, with no abstruse or strange ma-noeuvres. There is stability in the organization and in the management whichmakes us dependable on the inside and towards the outside.
What’s the strategy behind your success story?Today the group is managed by a team composed of three persons: my
brother Fabrizio, our partner Sergio Gallina and me. All of us share thesame objectives and responsibilities. Our task is to further develop andinnovate some of the peculiarities behind RC success, one of which is to beforerunners in many organizational and technological aspects.
For example, in 1984 we were about fifty people, with a turnover thattouched 5 million Euro; in 2001, with 216 people, our turnover has ex-ceeded 80 million Euro. This result has been attained thanks to our choice,dating back to 1980, to maintain inside this structure a strong componentat an engineering, marketing and sales level, by outsourcing a part of ourproduction, that is using some very specialized outside entities to manu-facture components or pieces based on our design.
How are you organized from the technical point of view?We have two technical organizations: one is purely dedicated to the re-search and development of our products and/or systems, the other fol-lows the product, from its engineering for production to its perfecting
Performances test room up to 800 kW
Air Conditioners assembly line
... in 1984 we were about fifty people,with a turnover that touched 5 millionEuro; in 2001, with 216 people, ourturnover has exceeded 80 million Euro.
Company presentation
14 RC GROUP SpA • General Catalogue • 155.EN.0504
according to the checks obtained from experience in the field.The technical organization of production is subdivided into 2 independ-
ent but inter-operative organizations, located in the production divisions ofPavia and Rome.
The management of all the technical issues of the group is the respon-sibility of Roberto Trecate, who has been working with us since 1968, whohas had a chance to see the product as a whole, from the phase of analysisof the needs of the client to the design, passing through the constructionand arriving at the installation and its maintenance in the field. A 360 de-gree view of the product, then, a very rare opportunity given the speciali-zation of the various fields. The research and development part is inte-grated with and collaborates daily with the technicians of the productionoffices in order to design new products and systems, without losing sightof their feasibility. At the moment when the prototype is accepted on thecommercial and performance level, the engineering is activated for theproduction and the successive commercial launch.
During my visit to the offices I noted a high level of computerization...In 1982 we had already developed software that permitted us to cre-
ate a virtual model of the product in order to be able to find out, with anacceptable margin of error, the performances even before having devel-oped the prototype. This software product was transformed into an elec-tronic catalogue that was distributed free of charge at our sales centresand among our clients in 1985.
It was perhaps one of the first electronic catalogues in our sector, andtoday it is fully integrated in our Enterprise Resource Planning software,since it has been turned into a Product Configurator for the manufacturingsystem. Today we are able to design the product and automatically gener-ate the software part that lets the distributor and the agent select it.
We care a lot about the computerized part which gives us daily sup-port that cannot be done without.
In 1983 we had already abolished drawing desks in favour of compu-ter-aided design (CAD), even though the operation really represented adisproportionate investment in our situation at that time.
Anticipating the times again in this aspect, we found ourselves readyfor the next steps with no effort. Today all products are developed with atridimensional CAD system, allowing an incredibly short Time to the Mar-ket vital to our success in the Information and Communication Technologybusiness. We have just implemented one of the most innovative ERP (sys-tems of resource planning for companies), for the real time managementof all corporate structures.
For years we have been using Internet to communicate with our salesnetwork and to give assistance by e-mail and we operate with a sophisti-cated system of Intranet that connects the 3 productive divisions in realtime at the level of voice, data and video.
The realization of Extranet is in progress which will permit our externalcollaborators to have direct access to all the company information regard-ing the products sold by them and to those currently in the catalogue.
Can you mention some other distinguishing organizational characteristics?In our company there are no managerial levels; it may be said that at
managerial level the company is “flat”.
RC WORLDproducts selection program
In 1982 we had already developed soft-ware that permitted us to create a vir-tual model of the product in order to beable to find out, with an acceptable mar-gin of error, the performances even be-fore having developed the prototype.
Medium Size Chiller assembly line
Company presentation
15RC GROUP SpA • General Catalogue • 155.EN.0504
Soluzioni Affidabiliper
Applicazioni Critiche
Of course there are persons who, apart from their daily work, havealso management duties, but there are no managers operating on the basisof data or information provided by someone else. Everybody has a well-defined job and the offices are managed independently.
And at the product level?Our basic philosophy is that of not creating simply a product, but mak-
ing it unique through a mixture of innovations and “plus”.
We feel, for example, that we are a leader company regarding thenoise limiting of the water chillers and for years we have catalogued, as astandard product, a whole array of water chillers called ELN, with excep-tional intrinsic characteristics of low sound levels.
At the beginning of the seventies we were the first to propose an aircooled water chiller with an inbuilt free-cooling system.
The present MAXIMO is the result of this thirty year experience thathas reached its high point in the original control software making an en-ergy savings possible that is still unequalled.
Confirming our desire to maintain an actual leadership in this sector,all MAXIMO chillers are now available with the patented Free-CoolingOptimizer system, that will double the energy savings normally achievedby a standard free-cooling system.
Also regarding the materials we have been the first to introduce somechanges which by now have been adopted by everyone: for example, startingin the eighties we were the first company in our field to utilize aluminiumprofile to make the structural part of the product (I am talking about airconditioners and water chillers); in the same years we started substitutingthe copper capillaries, a fragile point in the cooling circuit, with flexible plas-
CAD system for tridimensional design
Liquid chillers • Noise pressure level at 10m far
dB(A) 75
70
65
60
55
50
45
40
STD
LNO
ELN
20 70 110 400 880 kW
Outdoor air temperature
EER
(W/W
)
100
10
1-5 0 5 10 15 20 25 30 35 40 °C
www.rcgroup.it
Our basic philosophy is that of not cre-ating simply a product, but making itunique through a mixture of innovationsand “plus”.
... all MAXIMO chillers are now availablewith the patented Free-Cooling Optimizersystem, that will double the energy sav-ings normally achieved by a standardfree-cooling system.
Company presentation
1 = Water chiller with Free-Cooling Optimizer • 2 = Air cooled water chiller
16 RC GROUP SpA • General Catalogue • 155.EN.0504
tic pipes that were used in the air conditioning for automobiles.Then, still not satisfied with the performance of this product which had
a high porosity and therefore substantial losses over time, together with aMultinational operating in the field of plastic materials, we developed atype of material suitable for use in our field.
Now these flexible pipes are found in most good quality chillers, but forabout eight years we were the only company to have exclusivity. On thebasis of this experience we then proceeded to substitute with plastic ma-terial also the flow piping of compressors up to large dimensions.
Here the objective was not to eliminate breakdowns, but to limit thetransmission of the noise of the vibrations from the reciprocating com-pressor to the condensing system.
Today these applications are used by very many companies, but wewere the first to develop the idea and we promoted it.
In the field DPC we were the first to bring the compressors inside themachine in the environment, overcoming quite a lot of resistance from theclients, who were afraid of the noise and did not want to see repairmen intheir own data processing centres. We applied a whole series of expedi-ents so every problem has been overcome and now 99% of the units forthese centres have the compressor on the inside. We have always be-lieved in the need for innovation, not only on the product level but also onthe level of the component.
Another important aspect is that of regulation. Already by the end ofthe seventies we had electronic regulators with digital displays on ourmachines, which were substituted in 1984 with the first system of regula-tion using a microprocessor, completely developed by us from the hard-ware point of view as well as the software.
This experience has permitted us to develop a regulation which, dif-ferently from many others, really manages the unit. Indeed, all our con-trol systems with microprocessors come with the logic Proactive Con-trol System.
Thanks to this original system our control systems with microproc-essors are not only monitoring devices for what is happening, but theycontrol and regulate the complete functioning of the unit and the opera-tion of the security system, anticipating problems about to arise andguaranteeing in this way the continuous functioning of the unit even incritical situations.
The software used is innovative and patented, such as that for the heatpumps, called “Idea”, which makes it possible to obtain energy savings andefficiency decidedly superior to the average for the field.
Your company is one of the first of its field in Europe to obtain ISO 9000certification.
Actually we were the first company in our field in Europe to obtain ISO9000 certification; In Italy we were number 18, but those who preceded uswere of completely different types and dimensions.
Practically we already had an existing inside system of quality control;it meant simply to formalize it.
Today we have an office dedicated only to quality and we are repaidalso under this aspect: despite our being a somewhat small company, wehave been able, for example, to get contracts in the field of nuclear powerplants where the qualitative aspects, along with the security ones, are
MP2000microprocessor control system
Intelligent Defrosting system for Energy-saving Applications
... all our control systems with micro-processors come with the logicProactive Control System.Thanks to this original system our con-trol systems with microprocessors arenot only monitoring devices for what ishappening, but they control and regulatethe complete functioning of the unit andthe operation of the security system, an-ticipating problems about to arise andguaranteeing in this way the continuousfunctioning of the unit even in criticalsituations.
Company presentation
17RC GROUP SpA • General Catalogue • 155.EN.0504
Soluzioni Affidabiliper
Applicazioni Critiche
SOLUTIONnew air conditioning system for information technology
ISO 9000 corporate certification
particularly strict. Thanks to the organizational structure that we havecreated over the years we were able, in fact, to produce a whole series ofdocumentation that would have normally cost us a remarkable effort.
Another concept you care a lot about is “transparency”; what exactly doyou mean with this term?
Our whole operation is based on the maximum openness, from ourway of providing service to our availability to collaborate with designers,from our relationships with Distributors to the possibility of stages whichwe offer to students.
Talking about technical service, we are more oriented to transferringour know-how to the various outside centres and to our Distributors,rather than to intervene directly. Even though our service centres andDistributors are completely independent companies, they are treated as ifthey were an integral part of our Company and we are not afraid to pro-vide 100% of the information. Our company Extranet is in the finishingstages and it will permit the Distributor and the service centre to accessthe company know-how using a series of passwords. They will be able toget directly all the information regarding the product that has been soldand therefore, its complete history, from production to life in the field. Weare creating these systems so that they will seem to be automatic routinerather than duties.
Our Extranet will permit us to give a response in real time to any typeof request in order to constantly improve our service to our customers.
And what about the future?Capitalizing on our ability to provide the market with COMPLETE SOLU-
TIONS to air conditioning requirements is of the essence.SOLUTIONS in which products are only a part to the way we want to
differentiate our offer from competitor’s ones. SOLUTIONS that will allowus to take advantage of our 40 years of experience in this business.
SOLUTION, RC Group’s new air conditioning system aimed to serve thenew Information and Communication infrastructures, is our first concreteresult in this new way to interact with the market.
With SOLUTION the already interesting advantages offered by everysingle product are enhanced by the synergies created by their joint use.
SOLUTION is a new way to develop a system, to market it and to use itscharacteristics to allow an immediate and substantial return of invest-ment to the end user.
In the future, the real challenge in our sector will focus on solutions,not just on products.
In the future, the real challenge in oursector will focus on solutions, not juston products.
Company presentation
18 RC GROUP SpA • General Catalogue • 155.EN.0504
Albacom, Alcatel, Aletel, At&t, Belgacom, Blixer, Boujgue Telecom, British Telecom,Cegetel, Cerved Sinted, Colt, Comvik, EDS, France Telecom, Global Crossing, Hermes,Indosat, Iritel, Italtel, KPN, KPN Qwest, LDCom, Level 3, Mannesman, MCI Worldcom,Metroweb, Motorola, Netsiel, OTE, Pasifik Satelit Nusantara, PolishTelecom, Portugal Telecom, Post Danmark, Poste e Telegrafi, PtcTelecom, Retevision, Siemens, Stream, Swisscom, Telbank, Tele 2, Telecom Italia,Telecom South Africa, Telefonica, Telefonica Argentina, Telefony Brzeskie, TelefonyPolskie, Telenet, Telenokia, Telenor, Telia, Telkom, Telnet, Transpac, Unifon, Unisource.
Airtel, Alcatel, BlueTel, Boujgue Telecom, Cosmote, Ericsson, Ericsson Microwave,Libertel, Mannesman, Mercury Communications, Mobilcom, Motorola, Netcom GSM,Nokia, O-Tel-O, Omnitel, OTE, Orange, Proximus, PtcTelecom, Retevision Movil, Sie-mens, Sveriges Radio, Telecom Italia Mobile, Telefonica Moviles, Wind.
BANKSABN Bank, Alembank, AMRO Bank, Banca Agricola Milanese, Banca Arner, BancaCommerciale Italiana, Banca d’Italia, Banca del Lussemburgo, Banca di Roma, BancaNazionale del Lavoro, Banca Popolare di Milano, Banca Regionale Europea, BancaSella, Banca Toscana, Banco Ambrosiano Veneto, Bank of China Hua Qiao, BanqueBruxelles Lambert, Ca.Ri.Ge., Ca.Ri.P.Lo., Cassa di Risparmio di Firenze, Chase Man-hattan Bank, City Bank, Credit Agricole, Credit Suisse, Credito Italiano, Den NorskeBank, Deutsche Bank, Hypo Bank, Ing Bank, Istituto Bancario S. Paolo di Torino,Monte dei Paschi di Siena, Morgan Stanley, National WestBank, Paribas, Postbank,Rabo Bank, Swiss Bank Corporation, Union Bank of Switzerland.OFFICE BUILDINGSACI, Allianz Platz, Aok, Assicurazioni Generali, Bvk, Canal +, Club Med,Continentale, Eastern Pearl TV Tower, Fininvest, Gerling, IMI, Immo duTiomphe, INA, Kvb, Lloyd, Maa Assicurazioni, Pol-Kaufring (Canal +), RAI, RAS, RTLPlus, S. I. Les Eaux, Sat 1, ShangHai Zheng Xie, Sosintel, South Quay Plaza, StjarnTV, Sv Radio, SWIFT, Twice Trade Comm., Unibail, Videotime, Zbc.PUBLIC BODIESAem Milano, Acea Roma, Asl, Austrian Embassy - Bruxells, Avon & Sommerset PoliceH. Q., Borsa di Milano, British Government, Bundesbauddirektion Langer Eugen -Bonn, Bundeslander Versicherung - Wien, Camera dei Deputati, Edf - Nancy, EEC ArdenneAtrium & European Parliament - Bruxelles, Enea, Enel, Eni, Genio civile, Goteborg Posten,Insee - Lille, Israel Electrical Company, Istat, Supreme Court - Warsawa, Ministerodei Lavori Pubblici e del Tesoro, Ministry of Defence - Singapore, OMS - Geneva.
PUBLISHING INDUSTRIESDaily Express, Edipresse, Hurriyet Gazetecilik, Il Sole 24 Ore, Mondadori, PoligraficaS. Faustino, Rizzoli, Rotolito Lombarda.ELECTRONIC INDUSTRIESBarco, Beghelli, Bull, Cisco, Compaq, Digital, Ericsson, Fimi Phonola, Fujitsu,Getronics, Hewlett Packard, Honeywell, Ibm, Intel, Italtel, Magneti Marelli, Olivetti,Schneider Electric, Siemens, Telettra, Toshiba, Whirpool.CHEMICAL INDUSTRIESAgip, Du Pont, Enichem, Esso Italiana, Fisba Optik, Montell, Parek Chemical, Polfa,Procter & Gamble, Sika, Tioxide.MECHANICAL/STEEL INDUSTRIESAcciai Speciali Terni, Acciaierie Piombino, Alenia, Ansaldo, BMW, Bosch, CostruzioniAreonautiche Agusta, Electrocieplownia, Elsag Bailey, Fabrimetal, Ferrari, Fiat, Ford,Ilva, IVECO, Kroschu Kabelwerke, Laminazione sottile, Lucas Industries, Luxottica,
INFORMATION TECHNOLOGY
MOBILE COMMUNICATION
BANKING AND HI - TECH. OFFICES
INDUSTRIAL PROCESSES
References
19RC GROUP SpA • General Catalogue • 155.EN.0504
Soluzioni Affidabiliper
Applicazioni Critiche
Magneti Marelli, Magona, Merloni, Nissan, Nuova Magrini Galileo, Ocean, Opel,Renault, Sandvik, Skf, Trumpf, Valeo, Volkswagen.PHARMACEUTICAL INDUSTRIESAntibioticos, Astra Pharmaceutical, Bayer, Boots, GlaxoWellcome, Hoechst, Hoffmann- La Roche, Innogenetics, Janssen, Pharmaceutica, Johnson & Johnson, Merk Sharp& Dome, Novartis, Parek Chemicals, Pharmacia & Upjon, Polfa, Schiapparelli.FOOD INDUSTRIESBarilla, CocaCola, Dolma, Gancia, Heineken, Hilcona, Lipton, Masterfoods, Misura,Nestlé, Rana, Plasmon, Stollwerk, Unilever.
Algiers Nat. Library, Autogrill, Biblioteca Ambrosiana - Milano, Biblioteca Sormani -Milano, Casino di Venezia, Cine Warner - San Sebastian, City Hall - Luzern, CityTheatre - Beirut, Escuela de Musica - Madrid, Fiera di Modena, Forte Hotels, Galleriad’Arte Moderna - Torino, Hotel Europa&Regina - Venezia, Mc. Donald’s, MesseDusseldorf, Pablo Picasso Museum - Munster, Palazzo Civran Badoer -Venezia, Palazzo Ducale - Genova, Sporting Centre - Stockholm, Teatro Carlo Felice- Genova, Tianjin Sports Centre , Wettingen Sport Centre - Zurich.UNIVERSITYKth - Stockholm, Politecnico di Milano, Sthlm Universitet - Stockholm, U.l.b.University- Bruxelles, Univerity College London, Universidade Augiro - Aveiro, UniversitàCattolica - Milano, Università di Bologna, Università di Cagliari, Università diMessina, Università di Milano, Università di Venezia, University of Bath, Universityof Budapest, University of Manchester, University of Walles.
Alby Center, An-Hyp, Astrup Fearnley - Oslo, Bennet, Bio Famila - Saren,C+A, Carrefour, Cash & Carry, Coin, Comm. Center Targowek - Warsawa, Conad,Coop, Domus, El Corte Ingles, Esselunga, Euromercato, Hipercor, Ica Maxi, Ikea, LaRinascente, Oviesse, Rathausgalerie - Wuppertal, Rubens - Berchem, Sc Uno, StovnerCentre - Oslo, UPIM, World Trade Centre - Cardiff.
Aereoporto Marco Polo - Venezia, Aeroporto di Fiumicino - Roma, Aeroporto di Peretola- Firenze, Aeroporto F. Baracca - Roma, Aeroporto Malpensa 2000 - Varese, Aeroportomilitare di Ghedi, Aeroporto militare di Villafranca, Athens Airport, Atm Milano, CivilAviation Authority - Southampton, Ferrovie dello Stato, Flughafen Frankfurt, JakartaAirport, Johannesburg Airport, S.n.c.b. - N.m.b.s. - Bruxelles, Shanxi Hong Kong, ShipolAmsterdam, Wan Hai Airport - Wan Hai, Wu Han Station - Wu Han, Zurich Airport.
A.He.Pa - Thessaloniki, BPA Vent Montor - Linkoping, Chirurgische Klinik - Mun-ster, Clinique des Grangettes - Geneva, H. Famille - Reet, Hospital Cheux de Fonds,Hospital Civil - Charleroi, Hospital Santana - Lisbon, Hospital of Chur, Hospital ofSchiers, Istituto Gaslini - Genova, Istituto Tumori di Milano, Kantonsspital - Olten,Klinikum - Wuppertal, Krankenhaus - Waldbrol, Meb Nuclearmedizin - Bonn,Middelheim - Antwerpen, Ospedale S. Carlo di Nancy - Roma, Ospedale CivicoChirurgia Toracica - Palermo, Ospedale B. S. Lorenzo - Firenze, Ospedale Civicodi Palermo, Ospedale Civile di Pescara, Ospedale Civile di Treviso, Ospedale diAlessandria, Ospedale di Bel luno, Ospedale di Bolzano, Ospedale diBrunico, Ospedale di Como, Ospedale di Sondrio, Ospedale Gall iera -Genova, Ospedale Geriatrico - Sospiro, Ospedale S. Andrea - Ravenna, OspedaleS. Eugenio - Roma, Ospedale Pertini - Roma, Policlinico - Milano, Policlinico S.Matteo - Pavia, Policlinico S. Orsola - Bologna, Radium Hospitalet - Oslo, RomeAmerican Hospital - Roma, Spedali Civili - Brescia, St. Elizabeth Hospital - Uccle,US Hospital - Linkoping.
INDUSTRIAL PROCESSES
LEISURE AND ENTERTAINMENT
SHOPPING CENTERS
TRANSPORT
HOSPITALS
References
20 RC GROUP SpA • General Catalogue • 155.EN.0504
AIR CONDITIONING SYSTEM WITH UPFLOW AIR DELIVERY (OVER)It is the system traditionally used in the air conditioning field. The air distribution is from the top of the unit through a plenum deviceor through some ducts in case of false ceiling.The air flow in each area is predetermined during the design stage and it is not dependent on the actual state of the load to bedissipated.The system is normally applied in Comfort plants and in those plants having a defined low/medium room thermal loads density.
DIRECT EXPANSION UNITSAvailable up to 100 kW cooling capacity and over, these direct expansion air conditioning units are particularly suitable for low andmedium installations, where the compactness of the units and their simple installation are fundamental requirements. They are availableboth with remote air cooled condensers and in packaged version with built-in water cooled condenser. Equipped with Scroll typecompressors, characterized by high efficiency and low noise, RC GROUP direct expansion air conditioning units stand out for the buildingaccuracy, the high reliability and the extreme installation flexibility, thanks to a wide range of optional extras that have been conceivedto satisfy all demands.
CHILLED WATER UNITSSimilar to direct expansion units, the chilled water air conditioning units are suitable for medium - large installations matched todifferent kinds of liquid chillers.The range is very rich with a large number of optional extras suitable for every specific plant demand. The construction quality, thematerials used and the particular care at planning stage of RC GROUP chilled water units, guarantee noise levels among the lowest inthis product category.
PLAN
T TY
PEAir conditioners for hi-tech and comfort applications
21RC GROUP SpA • General Catalogue • 155.EN.0504
CONSOLE.DX.A.O • R407C • 6 ÷ 16 kWAir conditioners for hi-tech and comfort applications (air cooled).
CONSOLE.DX.W.O • R407C • 7 ÷ 17 kWAir conditioners for hi-tech and comfort applications (water cooled).
CONSOLE.CW.O • 6 ÷ 23 kWAir conditioners for hi-tech and comfort applications (chilled water).
PEGASUS.DX.A.O • R407C • 6 ÷ 93 kWAir conditioners for hi-tech and comfort applications (air cooled).
PEGASUS.DX.W.O • R407C • 6 ÷ 102 kWAir conditioners for hi-tech and comfort applications (water cooled).
PEGASUS.CW.O • 4 ÷ 144 kWAir conditioners for hi-tech and comfort applications (chilled water).
COMPACT.CW.O • 40 ÷ 217 kWAir conditioners for hi-tech and comfort applications (chilled water).
22 OVER VERSION
24
26
28
30
32
34
Air conditioners for hi-techand comfort applications
INDE
X
22 RC GROUP SpA • General Catalogue • 155.EN.0504
CONSOLE.DX.A.O - MODELCooling capacity (1) kWCooling capacity (2) kWAir flow m3/hCompressors n.Dimensions Length mm
Depth mmHeight mm
Net weight kgNoise pressure level (3) dB(A)
7.Z1 13.Z1 17.Z16,5 11,8 156,9 12,5 15,9
1300 2600 39001 1 1
1115 1515 1915465 465 465
1115 1115 1115130 200 26054 57 58,5
(1) Characteristics referred to evaporator air inlet at 24°C with 50% rH; condenser air inlet at 35°C.(2) Characteristics referred to evaporator air inlet at 27°C with 47% rH; condenser air inlet at 35°C.(3) Noise pressure 1m far from the unit in free field conditions.POWER SUPPLY: 400.3.50+Mp
Air conditioners for hi-tech and comfort applications - OVERTE
CHNI
CAL D
ATA
CONSOLE.DX.A.ODirect expansion air conditioning unit with remote air cooled condenser, suitable for under window installations
hi-tech. facilities and offices.
Ductable air flow delivery from the top or direct delivery into the room through directional grilles.
AdaptiveRangeA wide range of models and optional conceived to satisfy specific installation needs in terms of
capacity, filtering and ventilation.
IDEN
TIFIC
ATIO
N
23RC GROUP SpA • General Catalogue • 155.EN.0504
CHAR
ACTE
RIST
ICSHousing with aluminium profile frame •
with galvanized steel sheet panels
externally coated with PVC film
R407C refrigerant charge •
Scroll type compressors •
Centrifugal fans directly driven •
by electric motor
Microprocessor control system •
Electric board separated from air flow •
Door lock main switch •
Cooling connections •
through Rotalock valves
RS485 serial line •
Remote air cooled condenser •
Electric heating •
Hot water heating •
Humidification and dehumidification •
Hot gas reheating system •
Air delivery plenum •
OPTI
ONAL
CONSOLE.DX.A.OR407C • 6 ÷ 16 kW
The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.
DNA@RCThe large capacity precision
air conditioners technology
transferred to the units
dedicated to small areas.
QuickStartThe supply includes whatever is
needed for a correct unit working.
For the start-up the units only need
electrical, hydraulic and cooling
connections for a complete
installation in compliance with all the
current norms.
SpaceSaverInternal components lay out to
carry out all inspection and
maintenance operations from the
front of the unit, with no use of
side spaces.
HIGH
LIGHT
S
24 RC GROUP SpA • General Catalogue • 155.EN.0504
CONSOLE.DX.W.O - MODELCooling capacity (1) kWCooling capacity (2) kWAir flow m3/hCompressors n.Dimensions Length mm
Depth mmHeight mm
Net weight kgNoise pressure level (3) dB(A)
7.Z1 13.Z1 17.Z16,8 12,4 15,97,2 13,2 16,9
1300 2600 39001 1 1
1115 1515 1915465 465 465
1115 1115 1115150 220 28054 57 58,5
(1) Characteristics referred to evaporator air inlet at 24°C with 50% rH; condenser water inlet at 30°C.(2) Characteristics referred to evaporator air inlet at 27°C with 47% rH; condenser water inlet at 30°C.(3) Noise pressure 1m far from the unit in free field conditions.POWER SUPPLY: 400.3.50+Mp
TECH
NICA
L DAT
A
CONSOLE.DX.W.ODirect expansion air conditioning unit with built-in water cooled condenser, suitable for under window
installations hi-tech. facilities and offices.
Ductable air flow delivery from the top or direct delivery into the room through directional grilles.
WindowMateAir conditioners range designed for under window installation.
Air conditioners for hi-tech and comfort applications - OVERID
ENTI
FICAT
ION
25RC GROUP SpA • General Catalogue • 155.EN.0504
CHAR
ACTE
RIST
ICSHousing with aluminium profile frame •
with galvanized steel sheet panels
externally coated with PVC film
R407C refrigerant charge •
Scroll type compressors •
Centrifugal fans directly driven •
by electric motor
Microprocessor control system •
Electric board separated from air flow •
Door lock main switch •
RS485 serial line •
Water regulating valve •
Electric heating •
Hot water heating •
Humidification and dehumidification •
Hot gas reheating system •
Air delivery plenum •
OPTI
ONAL
CONSOLE.DX.W.OR407C • 7 ÷ 17 kW
The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.
RCProactiveMP2000 control and monitoring
system technology owned by RC
PROACTIVE, conceived to grant
continuous operation even in
emergency situations.
FastHeatLow thermal inertia system for
electric heating, without
ionization
effect on treated air.
ServiceFastCompressors, electric board and
electronic regulation system
housed in a technical compartment
separated from the air flow to
allow standard maintenance with
the unit in operation.
HIGH
LIGHT
S
26 RC GROUP SpA • General Catalogue • 155.EN.0504
CONSOLE.CW.O - MODELCooling capacity (1) kWCooling capacity (2) kWAir flow m3/hDimensions Length mm
Depth mmHeight mm
Net weight kgNoise pressure level (3) dB(A)
7 14 215,6 11,2 177,6 15,2 23
1300 2600 39001115 1515 1915465 465 465
1115 1115 1115110 175 23052 54,5 56
(1) Characteristics referred to evaporator air inlet at 24°C with 50% rH; chilled water inlet at 7°C.(2) Characteristics referred to evaporator air inlet at 27°C with 47,5% rH; chilled water inlet at 7°C.(3) Noise pressure 1m far from the unit in free field conditions.POWER SUPPLY: 400.3.50+Mp
TECH
NICA
L DAT
A
CONSOLE.CW.OChilled water feeding air conditioning unit, suitable for under window installations hi-tech. facilities
and offices.
Ductable air flow delivery from the top or direct delivery into the room through directional grilles.
CoolingDensityPlusOptimization system of internal lay out to grant the best ratio between the unit footprint and the
cooling capacity.
Air conditioners for hi-tech and comfort applications - OVERID
ENTI
FICAT
ION
27RC GROUP SpA • General Catalogue • 155.EN.0504
CHAR
ACTE
RIST
ICSHousing with aluminium profile frame •
with galvanized steel sheet panels
externally coated with PVC film
Centrifugal fans directly driven •
by electric motor
3 way proportional valve with •
emergency manual control
Microprocessor control system •
Electric board separated from air flow •
Door lock main switch •
RS485 serial line •
Electric heating •
Hot water heating •
Humidification and dehumidification •
Hot gas reheating system •
Air delivery plenum •
OPTI
ONAL
CONSOLE.CW.O5 ÷ 23 kW
The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.
ForcedDehumidificationSystem designed to keep the
room humidity without any air
flow restrictions prejudicial to
the cooling effectiveness.
EMCAll RC products are in compliance
with the norms about
electromagnetic compatibility.
SmartLinkSystem conceived for the
creation of a Local Area
Network (LAN), with unit
rotation and stand-by
management, without any
supplementary components.
HIGH
LIGHT
S
28 RC GROUP SpA • General Catalogue • 155.EN.0504
PEGASUS.DX.A.O - MODELSizeCooling capacity (1) kWCooling capaciity (2) kWAir flow m3/hCompressors n.Dimensions Length mm
Depth mmHeight mm
Net weight kgNoise pressure level (3) dB(A)
PEGASUS.DX.A.O - MODELSizeCooling capacity (1) kWCooling capaciity (2) kWAir flow m3/hCompressors n.Dimensions Length mm
Depth mmHeight mm
Net weight kgNoise pressure level (3) dB(A)
5.Z1 7.Z1 10.Z1 10.Z1 15.Z1 10.Z1 18.Z1 15.Z1 15.Z1 15.Z1 20.Z1 18.Z1 24.Z2 30.Z2 20.Z1S0 S0 S0 S1 S1 S2 S2 S3S S3 S4 S4 S5 S5 S5 S65,9 7 8,8 10,9 14,6 11,3 17,1 16,3 15,4 16,8 20,7 18,7 24,4 28 22,66,3 7,4 9,3 11,6 15,5 12 18,1 17,4 16,4 17,9 22 19,8 25,9 29,7 23,6
1580 1580 1580 3150 3150 3640 3640 5000 5000 5570 5570 6000 6000 6000 82001 1 1 1 1 1 1 1 1 1 1 1 2 2 2
645 645 645 645 645 755 755 760 900 1105 1105 1125 1125 1125 1360410 410 410 645 645 645 645 760 860 645 645 860 860 860 860
1680 1680 1680 1930 1930 1930 1930 1950 1950 1930 1930 1950 1950 1950 1950145 150 155 200 205 210 230 285 285 245 255 320 370 375 38051,5 51,5 51,5 52 52 54 54 55 55 54,5 54,5 55,6 55,6 55,6 58
24.Z2 30.Z2 36.Z2 30.Z2 40.Z2 40.Z2 52.Z2 52.Z2 60.Z2 74.Z2 88.Z2 60.Z2 74.Z2 88.Z2S6 S6 S6 S7 S7 S8 S8 S9 S9 S9 S9 S10 S10 S1026 30,1 34,7 31,3 38,8 41,5 49,8 53,6 60 73,3 81,6 65,3 78,6 87,9
27,5 32 36,9 33,3 41,5 44,2 53,1 57,1 64 78 86,6 69,6 83,8 938200 8200 8200 10400 10400 13500 13500 17000 17000 17000 17000 22800 24500 24500
2 2 2 2 2 2 2 2 2 2 2 2 2 21360 1360 1360 1750 1750 2210 2210 2680 2680 2680 2680 3415 3415 3415860 860 860 860 860 860 860 860 860 860 860 900 900 900
1950 1950 1950 1950 1950 1950 1950 1950 1950 1950 1950 1950 1950 1950425 430 445 580 600 700 820 950 980 1000 1030 1290 1300 131558 58 58 59 59 60 60 61,5 62,5 62,5 62,5 63,5 65,5 65,5
(1) Characteristics referred to evaporator air inlet at 24°C with 50% rH; condenser air inlet at 35°C.(2) Characteristics referred to evaporator air inlet at 27°C with 47% rH; condenser air inlet at 35°C.(3) Noise pressure 1m far from the unit in free field conditions.POWER SUPPLY: 230.1.50 for models 5.Z.1 and 7.Z.1• 400.3.50+Mp for other models
TECH
NICA
L DAT
A
AdaptiveRangeA wide range of models and optional conceived to satisfy specific installation needs in terms of
capacity, filtering and ventilation.
PEGASUS.DX.A.ODirect expansion air conditioning units with remote air cooled condenser.
Units are suitable for hi-tech. facilities, offices and comfort applications.
Ductable air flow delivery from the top or direct delivery into the room through a plenum device.
Air conditioners for hi-tech and comfort applications - OVERID
ENTI
FICAT
ION
29RC GROUP SpA • General Catalogue • 155.EN.0504
CHAR
ACTE
RIST
ICSHousing with aluminium profile frame •
with galvanized steel sheet panels
externally coated with PVC film
R407C refrigerant charge •
Scroll type compressors •
Centrifugal fans directly driven •
by electric motor
Microprocessor control system •
Electric board in separated •
technical compartment
Door lock main switch •
Cooling connections •
through Rotalock valves
RS485 serial line •
Remote control board •
Remote air cooled condenser •
Electric heating •
Hot water heating •
Drive system fans •
Humidification and dehumidification •
Compressors capacity control •
Double cooling circuit unit •
Extra-Circuit system •
Hot gas reheating system •
Air delivery plenum •
High efficiency filters •
OPTI
ONAL
PEGASUS.DX.A.OR407C • 6 ÷ 110 kW
The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.
PerformancePlusTandem SCROLL type
compressors to grant the
maximum energy efficiency in
any working condition.
MateIntegrated condensing control
system for stepless condenser fan
speed.
QuickStartThe supply includes whatever is
needed for a correct unit working. For
the start-up the units only need
electrical, hydraulic and cooling
connections for a complete installation
in compliance with all the current
norms.
HIGH
LIGHT
S
30 RC GROUP SpA • General Catalogue • 155.EN.0504
PEGASUS.DX.W.O - MODELSizeCooling capacity (1) kWCooling capacity (2) kWAir flow m3/hCompressors n.Dimensions Length mm
Depth mmHeight mm
Net weight kgNoise pressure level (3) dB(A)
PEGASUS.DX.W.O - MODELSizeCooling capacity (1) kWCooling capacity (2) kWAir flow m3/hCompressors n.Dimensions Length mm
Depth mmHeight mm
Net weight kgNoise pressure level (3) dB(A)
5.Z1 7.Z1 10.Z1 10.Z1 15.Z1 10.Z1 18.Z1 15.Z1 15.Z1 15.Z1 20.Z1 18.Z1 24.Z2 30.Z2 20.Z1S0 S0 S0 S1 S1 S2 S2 S3S S3 S4 S4 S5 S5 S5 S66,2 7,3 9,1 11,5 15,7 11,9 18,7 17,8 16,7 17,9 22,2 20,8 26,8 30,2 24,56,6 7,8 9,7 12,2 16,7 12,7 19,9 19 17,8 19,1 23,7 22,1 28,5 32 26,1
1580 1580 1580 3150 3150 3640 3640 5000 5000 5570 5570 6000 6000 6000 82001 1 1 1 1 1 1 1 1 1 1 1 2 2 2
645 645 645 645 645 755 755 760 900 1105 1105 1125 1125 1125 1360410 410 410 645 645 645 645 760 860 645 645 860 860 860 8601680 1680 1680 1930 1930 1930 1930 1950 1950 1930 1930 1950 1950 1950 1950160 165 170 200 215 220 240 295 295 255 265 330 385 390 39051,5 51,5 51,5 52 52 54 54 55 55 54,5 54,5 55,6 55,6 55,6 58
24.Z2 30.Z2 36.Z2 30.Z2 40.Z2 40.Z2 52.Z2 52.Z2 60.Z2 74.Z2 88.Z2 60.Z2 74.Z2 88.Z2S6 S6 S6 S7 S7 S8 S8 S9 S9 S9 S9 S10 S10 S10
28,8 32,7 27,1 34,3 43,3 46,6 55,2 58,6 66,2 79,6 88 70,6 86,8 9630,6 34,7 39,4 36,4 46,1 50,2 59,2 62,6 70,6 84,9 94 75,5 92,9 1028200 8200 8200 10400 10400 13500 13500 17000 17000 17000 17000 22800 24500 24500
2 2 2 2 2 2 2 2 2 2 2 2 2 21360 1360 1360 1750 1750 2210 2210 2680 2680 2680 2680 3415 3415 3415860 860 860 860 860 860 860 860 860 860 860 900 900 9001950 1950 1950 1950 1950 1950 1950 1950 1950 1950 1950 1950 1950 1950440 445 460 635 645 745 870 1000 1035 1055 1095 1350 1370 141058 58 58 59 59 60 60 61,5 62,5 62,5 62,5 63,5 65,5 65,5
(1) Characteristics referred to evaporator air inlet at 24°C with 50% rH; condenser water inlet at 30°C.(2) Characteristics referred to evaporator air inlet at 27°C with 47% rH; condenser water inlet at 30°C.(3) Noise pressure 1m far from the unit in free field conditions.POWER SUPPLY: 230.1.50 for models 5.Z.1 and 7.Z.1• 400.3.50+Mp for other models
TECH
NICA
L DAT
A
ServiceFastCompressors, electric board and electronic regulation system housed in a technical compartment
separated from the air flow to allow ordinary maintenance while unit in operation.
PEGASUS.DX.W.ODirect expansion air conditioning units with built-in water cooled condenser.
Units are suitable for hi-tech. facilities, offices and comfort applications.
Ductable air flow delivery from the top or direct delivery into the room through a plenum device.
Air conditioners for hi-tech and comfort applications - OVERID
ENTI
FICAT
ION
31RC GROUP SpA • General Catalogue • 155.EN.0504
CHAR
ACTE
RIST
ICSHousing with aluminium profile frame •
with galvanized steel sheet panels
externally coated with PVC film
R407C refrigerant charge •
Scroll type compressors •
Centrifugal fans directly driven •
by electric motor
Microprocessor control system •
Built-in water cooled condenser •
Electric board in separated •
technical compartment
Door lock main switch •
RS485 serial line •
Remote control board •
Electric heating •
Hot water heating •
Drive system fans •
Humidification and dehumidification •
Compressors capacity control •
Double cooling circuit unit •
Extra-Circuit system •
Hot gas reheating system •
Free-Cooling system •
Air delivery plenum •
High efficiency filters •
OPTI
ONAL
PEGASUS.DX.W.OR407C • 6 ÷ 125 kW
The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.
ForcedDehumidificationSystem designed to keep the
room humidity without any air
flow restrictions prejudicial to
the cooling effectiveness.
ExtraCircuitSystem designed for an optimal use
of the available cooling energy, or
as an integrated backup system.
Cool4FreeSystem conceived for indirect free
cooling, specially developed for
units equipped with built-in water
cooled condensers.
HIGH
LIGHT
S
32 RC GROUP SpA • General Catalogue • 155.EN.0504
PEGASUS.CW.O - MODELSizeCooling capacity (1) kWCooling capacity (2) kWAir flow m3/hDimensions Length mm
Depth mmHeight mm
Net weight kgNoise pressure level (3) dB(A)
PEGASUS.CW.O - MODELSizeCooling capacity (1) kWCooling capacity (2) kWAir flow m3/hDimensions Length mm
Depth mmHeight mm
Net weight kgNoise pressure level (3) dB(A)
6 13 16 20 21 25 26S0 S1 S2 S3S S3 S4 S55,9 13,4 16,4 20,3 20,5 24,8 268 18,3 22,2 27,8 28,2 33,6 35,2
1580 3150 3640 5000 5100 5570 6000645 645 755 760 900 1105 1125410 645 645 760 860 645 860
1680 1930 1930 1950 1950 1930 1950130 160 180 235 235 200 27051 52 53 54 54 53,5 54,6
34 44 58 71 100 109S6 S7 S8 S9 S10 S10T
34,1 44,2 57,9 71,3 100 108,946,4 58,4 78,5 97 131,6 143,98200 10400 13500 17000 22800 264001360 1750 2210 2680 3415 3415860 860 860 860 900 900
1950 1950 1950 1950 1950 1950325 410 500 620 910 97054,7 58 60 62 63 70
(1) Characteristics referred to air inlet at 24°C with 50% rH; chilled water inlet at 7°C.(2) Characteristics referred to air inlet at 27°C with 47% rH; chilled water inlet at 7°C.(3) Noise pressure 1m far from the unit in free field conditions.POWER SUPPLY: 230.1.50 for model S0 • 400.3.50+Mp for other models
TECH
NICA
L DAT
A
SpaceSaverInternal components lay-out to carry out all inspection and maintenance operations from the
front of the unit, with no use of side spaces.
PEGASUS.CW.OChilled water feeding air conditioning units suitable for hi-tech. facilities, offices and comfort applications.
Ductable air flow delivery from the top or direct delivery into the room through a plenum device.
Air conditioners for hi-tech and comfort applications - OVERID
ENTI
FICAT
ION
33RC GROUP SpA • General Catalogue • 155.EN.0504
CHAR
ACTE
RIST
ICSHousing with aluminium profile frame •
with galvanized steel sheet panels
externally coated with PVC film
Centrifugal fans directly driven •
by electric motor
Microprocessor control system •
3 way proportional valve with •
emergency manual control
Electric board in separated •
technical compartment
Door lock main switch •
RS485 serial line •
Remote control board •
Electric heating •
Hot water heating •
Drive system fans •
Humidification and dehumidification •
Extra-Circuit system •
Air delivery plenum •
High efficiency filters •
OPTI
ONAL
PEGASUS.CW.O5 ÷ 144 kW
The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.
FastHeatLow thermal inertia
system for electric
heating, without
ionization effect on
treated air.
DirectControlHumidification system directly
controlled by the main
microprocessor according to
owned algorithms for the
proportional working.
SmartLinkSystem conceived for the
creation of a Local Area Network
(LAN), with unit rotation and
stand-by management, without
any supplementary components.
HIGH
LIGHT
S
34 RC GROUP SpA • General Catalogue • 155.EN.0504
COMPACT.CW.O - MODELSizeCooling capacity (1) kWCooling capacity (2) kWCooling capacity (3) kWCooling capacity (4) kWAir flow m3/hDimensions Length mm
Depth mmHeight mmHeight (5) mm
Net weight kgNoise pressure level (6) dB(A)
42 71 92 110 116 138 166G0 G1 G2 G2S G3 G3S G4
41,8 71 91,8 -- 115,9 -- 166,456 95 119,9 -- 155,5 -- 217,4
26,2 44,6 57,4 71,4 73,2 88,9 104,339,5 67 86,7 104,7 109,1 122,2 157,18500 14600 18600 20000 24200 24200 340001.125 1.750 2.210 2.210 2.680 2.680 3.415900 900 900 900 900 900 900
1.950 1.950 1.950 1.950 1.950 1.950 1.9502.435 2.435 2.435 2.435 2.435 2.435 2.435290 445 545 570 680 700 98551 53 54 54,5 54 54 59
(1) Characteristics referred to air inlet at 24°C with 50% UR; chilled water inlet at 7°C.(2) Characteristics referred to air inlet at 27°C with 47% UR; chilled water inlet at 7°C.(3) Characteristics referred to air inlet at 24°C with 50% UR; chilled water inlet at 10°C.(4) Characteristics referred to air inlet at 27°C with 47% UR; chilled water inlet at 10°C.(5) Unit height with base frame for air intake directly from the room(6) Noise pressure 1m far from the unit in free field conditions with ducted airflow delivery.POWER SUPPLY: 400.3.50+Mp
TECH
NICA
L DAT
A
CoolingDensityPlusOptimization system of internal lay-out to grant the best ratio between the unit footprint and the
cooling capacity.
COMPACT.CW.OChilled water units with upflow air delivery, suitable for hi-tech. facilities.
Air intake from the bottom of the unit and ductable air flow delivery from the top or direct delivery
into the room through a plenum device.
Air conditioners for hi-tech and comfort applications - OVERID
ENTI
FICAT
ION
35RC GROUP SpA • General Catalogue • 155.EN.0504
The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.
VCoilCooling coils with
differentiated geometry for
the best use of exchange
surfaces.
CHAR
ACTE
RIST
ICSHousing with aluminium profile frame •
with galvanized steel sheet panels
externally coated with PVC film
Centrifugal fans with belt drive system •
Microprocessor control system •
3 way proportional valve with •
emergency manual control
Electric board in separated •
technical compartment
Door lock main switch •
RS485 serial line •
Remote control board •
Electric heating •
Hot water heating •
Humidification and dehumidification •
Base frame from direct air •
intake from the room
Air intake/delivery plenum •
High efficiency filters •
OPTI
ONAL
COMPACT.CW.O40 ÷ 217 kW
DBeltDouble belt drive system with
wide regulation possibility
(starting from model G2).
ForcedDehumidificationSystem designed to keep the room
humidity without any air flow
restrictions prejudicial to the cooling
effectiveness.
HIGH
LIGHT
S
36 RC GROUP SpA • General Catalogue • 155.EN.0504
AIR CONDITIONING SYSTEM WITH DOWNFLOW AIR DELIVERY THROUGH RAISED FLOOR (UNDER)The air distribution is from the bottom by means of the plenum between the building floor and the raised floor.This solution is usually applied in hi-tech. room a/c and it is most favourable when the thermal load is uniformly distributed in all areasof the room.
DIRECT EXPANSION UNITSAvailable up to 100 kW cooling capacity and over, these direct expansion air conditioning units are particularly suitable for low andmedium installations, where the compactness of the units and their simple installation are fundamental requirements. They are availableboth with remote air cooled condensers and in packaged version with built-in water cooled condenser. Equipped with Scroll typecompressors, characterized by high efficiency and low noise, RC GROUP direct expansion air conditioning units stand out for the buildingaccuracy, the high reliability and the extreme installation flexibility, thanks also to a wide range of optional extras that have beenconceived to satisfy all demands.
CHILLED WATER UNITSSimilar to direct expansion units, the chilled water air conditioning units are suitable for medium - large installations matched todifferent kinds of liquid chillers.The range is very rich with a large number of optional extras suitable for every specific plant demand. The construction quality, thematerials used and the particular care at planning stage of RC GROUP chilled water units, guarantee noise levels among the lowest inthis product category.
PLAN
T TY
PEClose control air conditioners - UNDER
37RC GROUP SpA • General Catalogue • 155.EN.0504
CONSOLE.DX.A.U • R407C • 7 ÷ 17 kWClose control air conditioners (air cooled).
CONSOLE.DX.W.U • R407C • 7 ÷ 18 kWClose control air conditioners (water cooled).
CONSOLE.CW.U • 7 ÷ 29 kWClose control air conditioners (chilled water).
PEGASUS.DX.A.U • R407C • 6 ÷ 93 kWClose control air conditioners (air cooled).
PEGASUS.DX.W.U • R407C • 6 ÷ 102 kWClose control air conditioners (water cooled).
PEGASUS.CW.U • 6 ÷ 132 kWClose control air conditioners (chilled water).
COMPACT.CW.U • 40 ÷ 218 kWClose control air conditioners (chilled water).
38 UNDER VERSION
40
42
44
46
48
50
Close control air conditionersIN
DEX
38 RC GROUP SpA • General Catalogue • 155.EN.0504
Close control air conditioners - UNDERTE
CHNI
CAL D
ATA CONSOLE.DX.A.U - MODEL
Cooling capacity (1) kWCooling capacity (2) kWAir flow m3/hCompressors n.Dimensions Length mm
Depth mmHeight mm
Net weight kgNoise pressure level (3) dB(A)
7.Z1 13.Z1 17.Z16,8 12,3 15,67,3 13,1 16,7
1900 3800 57001 1 1
1115 1515 1915465 465 465
1040 1040 1040130 200 26056 59 61
(1) Characteristics referred to evaporator air inlet at 24°C with 50% rH; condenser air inlet at 35°C.(2) Characteristics referred to evaporator air inlet at 27°C with 47% rH; condenser air inlet at 35°C.(3) Noise pressure 1m far from the unit in free field conditions.POWER SUPPLY: 400.3.50+Mp
CONSOLE.DX.A.UDirect expansion air conditioning units with remote air cooled condenser.
Units are suitable for under window installation hi-tech. facilities.
Downflow air delivery for air distribution through raised floor.
AdaptiveRangeA wide range of models and optional conceived to satisfy specific installation needs in terms of
capacity, filtering and ventilation.
IDEN
TIFIC
ATIO
N
39RC GROUP SpA • General Catalogue • 155.EN.0504
CHAR
ACTE
RIST
ICSHousing with aluminium profile frame •
with galvanized steel sheet panels
externally coated with PVC film
R407C refrigerant charge •
Scroll type compressors •
Centrifugal fans directly driven •
by electric motor
Microprocessor control system •
Technical compartment •
separated from the air flow
Door lock main switch •
Cooling connections •
through Rotalock valves
RS485 serial line •
Remote air cooled condenser •
Electric heating •
Hot water heating •
Humidification and dehumidification •
Hot gas reheating system •
Fresh air filter •
Antivibration rubber holder •
OPTI
ONAL
CONSOLE.DX.A.UR407C • 7 ÷ 17 kW
The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.
RCProactiveMP2000 control and
monitoring system technology
owned by RC PROACTIVE,
conceived to grant continuous
operation even in emergency
situations.
ForcedDehumidificationSystem designed to keep the room
humidity without any air flow
restrictions prejudicial to the
cooling effectiveness.
HIGH
LIGHT
S
MateIntegrated condensing control
system for stepless condenser fan
speed.
40 RC GROUP SpA • General Catalogue • 155.EN.0504
Close control air conditioners - UNDERTE
CHNI
CAL D
ATA CONSOLE.DX.W.U - MODEL
Cooling capacity (1) kWCooling capacity (2) kWAir flow m3/hCompressors n.Dimensions Length mm
Depth mmHeight mm
Net weight kgNoise pressure level (3) dB(A)
7.Z1 13.Z1 17.Z17,1 13 16,57,6 13,8 17,6
1900 3800 57001 1 1
1115 1515 1915465 465 465
1040 1040 1040150 220 28056 59 61
(1) Characteristics referred to evaporator air inlet at 24°C with 50% rH; condenser water inlet at 30°C.(2) Characteristics referred to evaporator air inlet at 27°C with 47% rH; condenser water inlet at 30°C.(3) Noise pressure 1m far from the unit in free field conditions.POWER SUPPLY: 400.3.50+Mp
CoolingDensityPlusOptimization system of internal lay-out to grant the best ratio between the unit footprint and the
cooling capacity.
CONSOLE.DX.W.UDirect expansion air conditioning unit with built-in water cooled condenser, suitable for hi-tech.
facilities applications with under window installation.
Downflow air delivery for air distribution through raised floor.
IDEN
TIFIC
ATIO
N
41RC GROUP SpA • General Catalogue • 155.EN.0504
CHAR
ACTE
RIST
ICSHousing with aluminium profile frame •
with galvanized steel sheet panels
externally coated with PVC film
R407C refrigerant charge •
Scroll type compressors •
Centrifugal fans directly driven •
by electric motor
Microprocessor control system •
Technical compartment •
separated from air flow
Door lock main switch •
RS485 serial line •
Water regulating valve •
Electric heating •
Hot water heating •
Humidification and dehumidification •
Hot gas reheating system •
Fresh air filter •
Antivibration rubber holder •
OPTI
ONAL
CONSOLE.DX.W.UR407C • 7 ÷ 18 kW
The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.
SmartLinkSystem conceived for the
creation of a Local Area Network
(LAN), with unit rotation and
stand-by management, without
any supplementary components.
3SpeedDirect drive fans with 3
selectable speed motor.
ServiceFastCompressors, electric board
and electronic regulation
system housed in a technical
compartment separated from
the air flow to allow standard
maintenance with the unit in
operation.
HIGH
LIGHT
S
42 RC GROUP SpA • General Catalogue • 155.EN.0504
Close control air conditioners - UNDERTE
CHNI
CAL D
ATA CONSOLE.CW.U - MODEL
Cooling capacity (1) kWCooling capacity (2) kWAir flow m3/hDimensions Length mm
Depth mmHeight mm
Net weight kgNoise pressure level (3) dB(A)
7 14 217 13,9 21,2
9,6 19,1 291900 3800 57001115 1515 1915465 465 465
1040 1040 1040110 175 23054 57 59
(1) Characteristics referred to air inlet at 24°C with 50% rH; chilled water inlet at 7°C.(2) Characteristics referred to air inlet at 27°C with 47% rH; chilled water inlet at 7°C.(3) Noise pressure 1m far from the unit in free field conditions.POWER SUPPLY: 400.3.50+Mp
WindowMateAir conditioners range designed for under window installation.
CONSOLE.CW.UChilled water feeding unit suitable for hi-tech. facilities applications with under window installation.
Downflow air delivery for air distribution through raised floor.
IDEN
TIFIC
ATIO
N
43RC GROUP SpA • General Catalogue • 155.EN.0504
CHAR
ACTE
RIST
ICSHousing with aluminium profile frame •
with galvanized steel sheet panels
externally coated with PVC film
Centrifugal fans directly driven •
by electric motor
3 way proportional valve with •
emergency manual control
Microprocessor control system •
Technical compartment •
separated from air flow
Door lock main switch •
RS485 serial line •
Electric heating •
Hot water heating •
Humidification and dehumidification •
Summer/Winter automatic •
working mode selection
Fresh air filter •
Antivibration rubber holder •
OPTI
ONAL
CONSOLE.CW.U 7 ÷ 29 kW
The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.
FastHeatLow thermal inertia
system for electric
heating, without ionization
effect on treated air.
ProHumidImmersed electrodes humidifier
with proportional steam
production.
SpaceSaverComponents internal lay-out to
carry out all inspection and
maintenance operations from
the front of the unit, with no use
of side spaces.
HIGH
LIGHT
S
44 RC GROUP SpA • General Catalogue • 155.EN.0504
TECH
NICA
L DAT
AClose control air conditioners - UNDER
PEGASUS.DX.A.U - MODELSizeCooling capacity (1) kWCooling capacity (2) kWAir flow m3/hCompressors n.Dimensions Length mm
Depth mmHeight mm
Net weight kgNoise pressure level (3) dB(A)
PEGASUS.DX.A.U - MODELSizeCooling capacity (1) kWCooling capacity (2) kWAir flow m3/hCompressors n.Dimensions Length mm
Depth mmHeight mm
Net weight kgNoise pressure level (3) dB(A)
(1) Characteristics referred to air inlet at 24°C with 50% rH; condenser air inlet at 35°C.(2) Characteristics referred to air inlet at 27°C with 47% rH; condenser air inlet at 35°C.(3) Noise pressure 1m far from the unit in free field conditions with air delivery under the raised floor..POWER SUPPLY: 230.1.50 for models 5.Z.1 e 7.Z.1 • 400.3.50+Mp for other models
5.Z1 7.Z1 10.Z1 10.Z1 15.Z1 10.Z1 18.Z1 15.Z1 15.Z1 15.Z1 20.Z1 18.Z1 24.Z2 30.Z2 20.Z1S0 S0 S0 S1 S1 S2 S2 S3S S3 S4 S4 S5 S5 S5 S65,9 7 8,8 10,9 14,6 11,3 17,1 16,3 15,4 16,8 20,7 18,7 24,4 28 22,66,3 7,4 9,3 11,6 15,5 12 18,1 17,4 16,4 17,9 22 19,8 25,9 29,7 23,6
1580 1580 1580 3150 3150 3640 3640 5000 5000 5570 5570 6000 6000 6000 82001 1 1 1 1 1 1 1 1 1 1 1 2 2 2
645 645 645 645 645 755 755 760 900 1105 1105 1125 1125 1125 1360410 410 410 645 645 645 645 760 860 645 645 860 860 860 860
1680 1680 1680 1930 1930 1930 1930 1950 1950 1930 1930 1950 1950 1950 1950145 150 155 200 205 210 230 285 285 245 255 320 370 375 38051,5 51,5 51,5 48 48 49 49 51 51 49,5 49,5 51,5 51,5 51,5 53
24.Z2 30.Z2 36.Z2 30.Z2 40.Z2 40.Z2 52.Z2 52.Z2 60.Z2 74.Z2 88.Z2 60.Z2 74.Z2 88.Z2S6 S6 S6 S7 S7 S8 S8 S9 S9 S9 S9 S10 S10 S1026 30,1 34,7 31,3 38,8 41,5 49,8 53,6 60 73,3 81,6 65,3 78,6 87,9
27,5 32 36,9 33,3 41,5 44,2 53,1 57,1 64 78 86,6 69,6 83,8 938200 8200 8200 10400 10400 13500 13500 17000 17000 17000 17000 22800 24500 24500
2 2 2 2 2 2 2 2 2 2 2 2 2 21360 1360 1360 1750 1750 2210 2210 2680 2680 2680 2680 3415 3415 3415860 860 860 860 860 860 860 860 860 860 860 900 900 900
1950 1950 1950 1950 1950 1950 1950 1950 1950 1950 1950 1950 1950 1950425 430 445 580 600 700 820 950 980 1000 1030 1290 1300 131553 53 53 55 55 56 56 58 58 58 58 60 62 62
AdaptiveRangeA wide range of models and optional conceived to satisfy specific installation needs in terms of
capacity, filtering and ventilation.
PEGASUS.DX.A.UDirect expansion air conditioning units with and air cooled condenser suitable for hi-tech. facilities applications
and offices.
Downflow air delivery for air distribution through raised floor.
IDEN
TIFIC
ATIO
N
45RC GROUP SpA • General Catalogue • 155.EN.0504
CHAR
ACTE
RIST
ICSHousing with aluminium profile frame •
with galvanized steel sheet panels
externally coated with PVC film
R407C refrigerant charge •
Scroll type compressors •
Centrifugal fans directly driven •
by electric motor
Microprocessor control system •
Electric board in separated •
technical compartment
Door lock main switch •
Cooling connections through •
Rotalock valves
RS485 serial line •
Remote control board •
Remote air cooled condenser •
Electric heating •
Hot water heating •
Drive system fans •
Humidification and dehumidification •
Compressors capacity control •
Double cooling circuit unit •
Extra-Circuit system •
Hot gas reheating system •
Air intake/delivery plenum •
High efficiency filters •
OPTI
ONAL
PEGASUS.DX.A.UR407C • 6 ÷ 93 kW
The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.
ExtraCircuitSystem designed for an
optimal use of the
available cooling energy,
or as an integrated
backup system.
PerformancePlusTandem SCROLL type
compressors to grant the
maximum energy efficiency in
any working condition.
ForcedDehumidificationSystem designed to keep the
room humidity without any air
flow restrictions prejudicial to
the cooling effectiveness.
HIGH
LIGHT
S
46 RC GROUP SpA • General Catalogue • 155.EN.0504
PEGASUS.DX.W.U - MODELSizeCooling capacity (1) kWCooling capacity (2) kWAir flow m3/hCompressors n.Dimensions Length mm
Depth mmHeight mm
Net weight kgNoise pressure level (3) dB(A)
PEGASUS.DX.W.U - MODELSizeCooling capacity (1) kWCooling capacity (2) kWAir flow m3/hCompressors n.Dimensions Length mm
Depth mmHeight mm
Net weight kgNoise pressure level (3) dB(A)
5.Z1 7.Z1 10.Z1 10.Z1 15.Z1 10.Z1 18.Z1 15.Z1 15.Z1 15.Z1 20.Z1 18.Z1 24.Z2 30.Z2 20.Z1S0 S0 S0 S1 S1 S2 S2 S3S S3 S4 S4 S5 S5 S5 S66,2 7,3 9,1 11,5 15,7 11,9 18,7 17,8 16,7 17,9 22,2 20,8 26,8 30,2 24,56,6 7,8 9,7 12,2 16,7 12,7 19,9 19 17,8 19,1 23,7 22,1 28,5 32 26,1
1580 1580 1580 3150 3150 3640 3640 5000 5000 5570 5570 6000 6000 6000 82001 1 1 1 1 1 1 1 1 1 1 1 2 2 2
645 645 645 645 645 755 755 760 900 1105 1105 1125 1125 1125 1360410 410 410 645 645 645 645 760 860 645 645 860 860 860 8601680 1680 1680 1930 1930 1930 1930 1950 1950 1930 1930 1950 1950 1950 1950160 165 170 200 215 220 240 295 295 255 265 330 385 390 39051,5 51,5 51,5 48 48 49 49 51 51 49,5 49,5 51,5 51,5 51,5 53
24.Z2 30.Z2 36.Z2 30.Z2 40.Z2 40.Z2 52.Z2 52.Z2 60.Z2 74.Z2 88.Z2 60.Z2 74.Z2 88.Z2S6 S6 S6 S7 S7 S8 S8 S9 S9 S9 S9 S10 S10 S10
28,8 32,7 37,1 34,3 43,3 46,6 55,2 58,6 66,2 79,6 88 70,6 86,8 9630,6 34,7 39,6 36,4 46,1 50,2 59,2 62,6 70,6 84,9 94 75,5 92,9 1028200 8200 8200 10400 10400 13500 13500 17000 17000 17000 17000 22800 24500 24500
2 2 2 2 2 2 2 2 2 2 2 2 2 21360 1360 1360 1750 1750 2210 2210 2680 2680 2680 2680 3415 3415 3415860 860 860 860 860 860 860 860 860 860 860 900 900 9001950 1950 1950 1950 1950 1950 1950 1950 1950 1950 1950 1950 1950 1950440 445 460 635 645 745 870 1000 1035 1055 1095 1350 1370 141053 53 53 55 55 56 56 58 58 58 58 60 62 62
(1) Characteristics referred to air inlet at 24°C with 50% rH; condenser water inlet at 30°C.(2) Characteristics referred to air inlet at 27°C with 47% rH; condenser water inlet at 30°C.(3) Noise pressure 1m far from the unit in free field conditions with air delivery under the raised floor..POWER SUPPLY: 230.1.50 for models 5.Z.1 e 7.Z.1 • 400.3.50+Mp for other models
TECH
NICA
L DAT
AClose control air conditioners - UNDER
SmartLinkSystem conceived for the creation of a Local Area Network (LAN), with unit rotation and stand-by
management, without any supplementary components.
PEGASUS.DX.W.UDirect expansion air conditioning units with downflow air delivery and built-in water cooled condenser, suitable
for hi-tech. facilities and offices.
Downflow air delivery for air distribution through raised floor.
IDEN
TIFIC
ATIO
N
47RC GROUP SpA • General Catalogue • 155.EN.0504
CHAR
ACTE
RIST
ICSHousing with aluminium profile frame •
with galvanized steel sheet panels
externally coated with PVC film
R407C refrigerant charge •
Scroll type compressors •
Centrifugal fans directly driven •
by electric motor
Microprocessor control system •
Built-in water cooled condenser •
Electric board in separated •
technical compartment
Door lock main switch •
RS485 serial line •
Remote control board •
Electric heating •
Hot water heating •
Drive system fans •
Humidification and dehumidification •
Compressors capacity control •
Double cooling circuit unit •
Extra-Circuit system •
Hot gas reheating system •
Free-Cooling system •
Air intake/delivery plenum •
High efficiency filters •
OPTI
ONAL
PEGASUS.DX.W.UR407C • 6 ÷ 102 kW
The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.
NoiseControlNoise deading cups for a
further reduction of the
noise from the
compressors.
Cool4FreeSystem conceived for indirect free
cooling, specially developed for
units equipped with built-in water
cooled condensers.
QuickStartThe supply includes whatever is
needed for a correct unit
working. For the start-up the
units only need electrical,
hydraulic and cooling
connections for a complete
installation in compliance with
all the current norms.
HIGH
LIGHT
S
48 RC GROUP SpA • General Catalogue • 155.EN.0504
PEGASUS.CW.U - MODELSizeCooling capacity (1) kWCooling capacity (2) kWAir flow m3/hDimensions Length mm
Depth mmHeight mm
Net weight kgNoise pressure level (3) dB(A)
PEGASUS.CW.U - MODELSizeCooling capacity (1) kWCooling capacity (2) kWAir flow m3/hDimensions Length mm
Depth mmHeight mm
Net weight kgNoise pressure level (3) dB(A)
6 13 16 20 21 25S0 S1 S2 S3S S3 S45,9 13,4 16,4 20,3 20,5 24,88 18,3 22,2 27,8 28,2 33,6
1580 3150 3640 5000 5100 5570645 645 755 760 900 1105410 645 645 760 860 645
1680 1930 1930 1950 1950 1930130 160 180 235 235 20051 45,7 46,8 48 48 47,5
26 34 44 58 71 100S5 S6 S7 S8 S9 S1026 34,1 44,2 57,9 71,3 100
35,2 46,4 58,4 78,5 97 131,66000 8200 10400 13500 17000 228001125 1360 1750 2210 2680 3415860 860 860 860 860 900
1950 1950 1950 1950 1950 1950270 325 410 500 620 91048 51 53 55,2 57 58,3
(1) Characteristics referred to air inlet at 24°C with 50% rH; chilled water inlet at 7°C.(2) Characteristics referred to air inlet at 27°C with 47% rH; chilled water inlet at 7°C.(3) Noise pressure 1m far from the unit in free field conditions with air delivery under the raised floor.POWER SUPPLY: 230.1.50 for model S0 • 400.3.50+Mp for other models
TECH
NICA
L DAT
AClose control air conditioners - UNDER
TopRateSystem designed to achieve the maximum energy saving in 24x365 working installations, thanks
to external indirect SCR free-cooling system which is integrated to the set-point compensation
software standard supplied on all CW units.
PEGASUS.CW.UChilled water feeding units with downflow air delivery, suitable for hi-tech. facilities applications and offices.
Downflow air delivery for air distribution through raised floor.
IDEN
TIFIC
ATIO
N
49RC GROUP SpA • General Catalogue • 155.EN.0504
CHAR
ACTE
RIST
ICSHousing with aluminium profile frame •
with galvanized steel sheet panels
externally coated with PVC film
Centrifugal fans directly driven •
by electric motor
Microprocessor control system •
3 way proportional valve with •
emergency manual control
Electric board in separated •
technical compartment
Door lock main switch •
RS485 serial line •
Remote control board •
Electric heating •
Hot water heating •
Drive system fans •
Humidification and dehumidification •
Extra-Circuit system •
Air intake/delivery plenum •
High efficiency filters •
OPTI
ONAL
PEGASUS.CW.U6 ÷ 132 kW
The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.
YRFanPossibility to choose among
a wide range of both direct
and belt drive fan section.
ProHumidImmersed electrodes humidifier
with proportional
administration of steam
production.
RCProactiveMP2000 control and monitoring
system technology owned by RC
PROACTIVE, conceived to grant
continuous operation even in
emergency situations.
HIGH
LIGHT
S
50 RC GROUP SpA • General Catalogue • 155.EN.0504
COMPACT.CW.U - MODELSizeCooling capacity (1) kWCooling capacity (2) kWCooling capacity (3) kWCooling capacity (4) kWAir flow m3/hDimensions Length mm
Depth mmHeight mm
Net weight kgNoise pressure level (5) dB(A)
42 71 92 110 116 138 166G0 G1 G2 G2S G3 G3S G4
41,8 71 91,8 -- 115,9 -- 166,456 95 119,9 -- 155,5 -- 217,4
26,2 44,6 57,4 71,4 73,2 88,9 104,339,5 67 86,7 104,7 109,1 122,2 157,18500 14600 18600 20000 24200 24200 340001125 1750 2210 2210 2680 2680 3415900 900 900 900 900 900 1100
1950 1950 1950 1950 1950 1950 1950290 445 545 570 680 700 103551 53 54 54,5 54 54 59
(1) Characteristics referred to air inlet at 24°C with 50% rH; chilled water inlet at 7°C.(2) Characteristics referred to air inlet at 27°C with 47% rH; chilled water inlet at 7°C.(3) Characteristics referred to air inlet at 24°C with 50% rH; chilled water inlet at 10°C.(4) Characteristics referred to air inlet at 27°C with 47% rH; chilled water inlet at 10°C.(5) Noise pressure 1m far from the unit in free field conditions with air delivery under the raised floor.POWER SUPPLY: 400.3.50+Mp
TECH
NICA
L DAT
AClose control air conditioners - UNDER
CoolingDensityPlus200kW in less than 4m2 (DF=50 Kw/m2), the close control air conditioning unit with the highest
cooling density (kW per m2 of plan space) currently available in the market nowadays.
COMPACT.CW.UHigh capacity chilled water feeding units suitable for hi-tech. facilities applications.
Downflow air delivery for air distribution through raised floor.
IDEN
TIFIC
ATIO
N
51RC GROUP SpA • General Catalogue • 155.EN.0504
CHAR
ACTE
RIST
ICSHousing with aluminium profile frame •
with galvanized steel sheet panels
externally coated with PVC film
Belt drive system centrifugal fans •
Microprocessor control system •
3 way proportional valve with •
emergency manual control
Electric board in separated •
technical compartment
Door lock main switch •
RS485 serial line •
Remote control board •
Electric heating •
Hot water heating •
Humidification and dehumidification •
Air intake/delivery plenum •
High efficiency air filters •
OPTI
ONAL
COMPACT.CW.U40 ÷ 218 kW
The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.
Easy@ServePossibility of air filters
removal from the front
without opening any access
panels.
EMCAll RC products are in
compliance with the norms
about electromagnetic
compatibility.
SpaceSaverInternal components lay-out
to carry out all inspection
and maintenance operations
from the front of the unit,
with no use of side spaces.
HIGH
LIGHT
S
52 RC GROUP SpA • General Catalogue • 155.EN.0504
THE AIR-CONDITIONING SYSTEM WITH DISPLACEMENT AIR DELIVERYThe air-conditioning system with displacement air discharge is based on the principle that the air is distributed at a very lowspeed, while enabling a cooling effect by convection.This concept has been adjusted and applied by RC GROUP to the air-conditioning of telephone exchanges and rooms where theconcentration of electronic equipment is considerable, in order to maximise and optimise the results that can be obtained inthese specific ambients.
The modern Telecom devices have the aim of heat dissipation by air suction from the lower side close to the floor, and discharging itfrom the top. The air circulation in the equipment can be either natural, by convection, or in a forced way, through dedicated internalventilation systems.RC GROUP displacement system creates a cushion of cold air at the floor level, thanks to proprietary COLDLAYER technology, which isavailable for all the equipment installed in the room, and can reach also the equipment located in critical positions, thanks to patentedAIRRAIL® injectors.Every electronic equipment will “absorb” the amount of cold required to maintain a correct temperature level inside, through anatural convection effect.The greater the load inside the electronic equipment, the greater this effect.So, every electronic equipment uses only the amount required to dissipate its own thermal load, which is generated by maximising theresult and the energy efficiency of the system.This allows a better and more constant cooling of the electronic equipment ensuring the possibility to meet in real time any loadchanges, without any waste of energy.More than 2000 installations equipped with the RC GROUP displacement system have allowed our R&D division to develop, test andpatent the MISTRAL® control system.MISTRAL® ensures a perfect stratification of the temperatures in the room, as well as a perfect thermodynamic efficiency for theplant under any working conditions.MISTRAL®, thanks to the EFFICIENTFLOW technology, allows the system to adjust itself in real time to any load change, in terms ofquantity and distribution, while ensuring the best energy efficiency.
DIRECT EXPANSION UNITSAvailable up to 47 kW cooling capacity and over, these direct expansion air conditioning units are particularly suitable for low andmedium installations, where the compactness of the units and their simple installation are fundamental requirements.They are available both with remote air cooled condensers and in packaged version with built-in water cooled condenser.Equipped with Scroll type compressor, characterized by high efficiency and low noise, RC GROUP direct expansion air conditioning unitsstand out for the building accuracy, the high reliability and the extreme installation flexibility, thanks also to a wide range of optionalextras that have been conceived to satisfy all demands.
CHILLED WATER UNITSSimilar to direct expansion units, the HEAT HUNTER chilled water air conditioning units are suitable for variable water flow plantmatched to MAXIMO OPTIMIZER liquid chillers series.The range is very rich with a large number of optional extras suitable for every specific plant demand. The construction quality, thematerials used and the particular care at planning stage of RC GROUP chilled water units, guarantee noise levels among the lowest inthis product category.
PLAN
T TY
PEClose control air conditioners withDisplacement air delivery
53RC GROUP SpA • General Catalogue • 155.EN.0504
54 HEAT HUNTER
56
58
Close control air conditionerswith Displacement air delivery
INDE
X HEAT HUNTER.DX • 6 ÷ 45 kWClose control air conditioners (air cooled).
HEAT HUNTER.DW • 6 ÷ 47 kWClose control air conditioners (water cooled).
HEAT HUNTER.CW • 10 ÷ 65 kWClose control air conditioners (chilled water).
54 RC GROUP SpA • General Catalogue • 155.EN.0504
TECH
NICA
L DAT
A HEAT HUNTER.DX - MODELSizeCooling capacity (1) kWCooling capacity (2) kWCooling capacity (3) kWAir flow m3/hCompressors n.Dimensions Length mm
Depth mmHeight mm
Net weight kgNoise pressure level (4) dB(A)
(1) Characteristics referred to air inlet at 24°C with 50% rH; condenser air inlet at 35°C.(2) Characteristics referred to air inlet at 27°C with 42% rH; condenser air inlet at 35°C.(3) Characteristics referred to air inlet at 30°C with 35% rH; condenser air inlet at 35°C.(3) Radiated noise pressure 1m far from the unit in free field conditions.POWER SUPPLY: 400.3.50+Mp
007 009 010 013 015 016 020 023 026 030 037 045HH0 HH0 HH0 HH1 HH1 HH1 HH2 HH2 HH2 HH2 HH3 HH36,5 7,5 8,3 11,2 12,9 15,2 17,9 19,8 23,1 26,9 31,7 39,97 8,2 8,9 12,2 13,4 15,8 19,2 21,7 24,9 27,8 34,7 41,1
7,5 8,7 9,5 13 14,6 16,2 20,4 23,2 26,5 30,1 36,9 44,82200 2200 2200 3330 3330 3330 6660 6660 6660 6660 10000 10000
1 1 1 1 1 1 1 1 1 1 1 1785 785 785 1470 1470 1470 2005 2005 2005 2005 2540 2540600 600 600 600 600 600 600 600 600 600 600 600
1980 1980 1980 1980 1980 1980 1980 1980 1980 1980 1980 1980205 205 205 310 320 320 390 390 425 440 530 54045,7 45,7 45,6 48,4 49,5 49,8 51,9 52,2 53,5 56,1 56,6 57,3
ColdLayerRC proprietary technology to exploit at best the advantages of displacement air distribution,
tested in more than 2000 installations.
HEAT HUNTER.DXDirect expansion air conditioning units with remote air cooled condenser, suitable for hi-tech. facilities
applications and and telecom exchanges.
Displacement mode air delivery for air distribution directly into the room.
IDEN
TIFIC
ATIO
NClose control air conditioners withDisplacement air delivery
55RC GROUP SpA • General Catalogue • 155.EN.0504
PatentCH
ARAC
TERI
STIC
SBase in aluminium profile frame painted •
with epoxy powders, galvanized steel
inner frame and galvanized steel sheet
panels externally coated with PVC film
R407C refrigerant charge •
Scroll type compressor •
Inverter controlled centrifugal fans •
directly driven by electric motor
Microprocessor control system •
Electric board in separated •
technical compartment
Door lock main switch •
Cooling connections through •
Rotalock valves
RS485 serial line •
Remote air cooled condenser •
Electric heater •
Humidification and dehumidification •
Direct Free-Cooling system •
Condensate discharge pump •
Compressor noise deading cup •
High efficiency filters •
Remote temperature sensor •
OPTI
ONAL
HEAT HUNTER.DXR407C • 6 ÷ 45 kW
The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.
HIGH
LIGHT
S
HoneyCombAir distribution grid
featuring an optimised
geometry, to increase the
ColdLayer effect.
Air-Rail®System patented by RC, consisting of a series of
aerodynamic inductors, to optimise the laminar air flow in
the actual conditions of installation and positioning.
FastHeatLow thermal inertia system
for electric heating,
without ionization
effect on treated air.
56 RC GROUP SpA • General Catalogue • 155.EN.0504
TECH
NICA
L DAT
A HEAT HUNTER.DW - MODELSizeCooling capacity (1) kWCooling capacity (2) kWCooling capacity (3) kWAir flow m3/hCompressors n.Dimensions Length mm
Depth mmHeight mm
Net weight kgNoise pressure level (4) dB(A)
(1) Characteristics referred to air inlet at 24°C with 50% rH; water to the condenser 29,5-35°C.(2) Characteristics referred to air inlet at 27°C with 42% rH; water to the condenser 29,5-35°C.(3) Characteristics referred to air inlet at 30°C with 35% rH; water to the condenser 29,5-35°C.(3) Radiated noise pressure 1m far from the unit in free field conditions.POWER SUPPLY: 400.3.50+Mp
007 009 010 013 015 016 020 023 026 030 037 045HH0 HH0 HH0 HH1 HH1 HH1 HH2 HH2 HH2 HH2 HH3 HH36,7 8,2 9,3 11,9 14,1 16,6 19,7 21,3 25,4 29,4 35,9 44,37,4 8,5 9,6 12,9 14,6 17,2 21,1 23,3 26,4 30,4 38,8 45,87,9 9,4 10,5 13,8 15,8 17,8 22,8 24,9 29 31,4 41,3 47,3
2200 2200 2200 3330 3330 3330 6660 6660 6660 6660 10000 100001 1 1 1 1 1 1 1 1 1 1 1
785 785 785 1470 1470 1470 2005 2005 2005 2005 2540 2540600 600 600 600 600 600 600 600 600 600 600 600
1980 1980 1980 1980 1980 1980 1980 1980 1980 1980 1980 1980215 215 215 320 340 340 405 405 440 455 550 56545,7 45,7 45,6 48,4 49,5 49,8 51,9 52,2 53,5 56,1 56,6 57,3
IDEN
TIFIC
ATIO
NClose control air conditioners withDisplacement air delivery
DirectCoolProportional system for direct free-cooling, completely controlled by the microprocessor, for an
extreme reduction of compressor working hours and a high energy costs saving.
HEAT HUNTER.DWDirect expansion air conditioning units with built-in water cooled condenser, suitable for hi-tech. facilities
applications and and telecom exchanges.
Displacement mode air delivery for air distribution directly into the room.
57RC GROUP SpA • General Catalogue • 155.EN.0504
CHAR
ACTE
RIST
ICSBase in aluminium profile frame painted •
with epoxy powders, galvanized steel
inner frame and galvanized steel sheet
panels externally coated with PVC film
R407C refrigerant charge •
Scroll type compressor •
Inverter controlled centrifugal fans •
directly driven by electric motor
Microprocessor control system •
Built-in water cooled condenser •
Electric board in separated •
technical compartment
Door lock main switch •
RS485 serial line •
Proportional electric heater •
Humidification and dehumidification •
Direct Free-Cooling system •
Condensate discharge pump •
Compressor noise deading cup •
High efficiency filters •
Remote temperature sensor •
OPTI
ONAL
HEAT HUNTER.DWR407C • 6 ÷ 47 kW
The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.
HIGH
LIGHT
S
Design@RCA new method to
“coat” the
product, which
becomes fit for
the most
demanding
architectural
requirements.
MP.COMThe new RC GROUP microprocessor control generation able to
communicate with the most advanced supervision systems.
MP.COM is equipped with a flash memory running a GSM modem, able
to send SMS alarm messages, and with a Data Logger working as a
“black box” for a correct analysis of failure causes.
1 2 3 4
M P . C O M g r a p h i c i n t e r f a c e
5 76
8
RC GROUP
Patent
Mistral®Thanks to the MISTRAL patented control logic, Heat Hunter can
maintain a perfect stratification of the room air, while ensuring
the best thermodynamic efficiency under any working
conditions and with any internal load.
58 RC GROUP SpA • General Catalogue • 155.EN.0504
TECH
NICA
L DAT
A HEAT HUNTER.CW - MODELSizeCooling capacity (1) kWCooling capacity (2) kWCooling capacity (3) kWCooling capacity (4) kWCooling capacity (5) kWCooling capacity (6) kWAir flow m3/hDimensions Length mm
Depth mmHeight mm
Net weight kgNoise pressure level (7) dB(A)
(1) Characteristics referred to air inlet at 24°C with 50% rH; chilled water temperature 7/12°C - 0% glycol solution.(2) Characteristics referred to air inlet at 27°C with 42% rH; chilled water temperature 7/12°C - 0% glycol solution.(3) Characteristics referred to air inlet at 30°C with 35% rH; chilled water temperature 7/12°C - 0% glycol solution.(4) Characteristics referred to air inlet at 24°C with 50% rH; chilled water temperature 9/14°C - 0% glycol solution.(5) Characteristics referred to air inlet at 27°C with 42% rH; chilled water temperature 9/14°C - 0% glycol solution.(6) Characteristics referred to air inlet at 30°C with 35% rH; chilled water temperature 9/14°C - 0% glycol solution.(7) Radiated noise pressure 1m far from the unit in free field conditions.POWER SUPPLY: 400.3.50+Mp
014 021 025 044 066HH0 HH1 HH1 HH2 HH310,9 17,9 25,0 34,2 49,712,6 20,7 29,0 39,5 57,514,2 23,1 32,5 44,2 64,48,1 13,5 18,2 22,9 36,99,8 16,3 22,2 28,2 44,8
11,4 18,8 25,9 33,6 51,72200 3330 5500 6660 10000785 1470 1470 2005 2540600 600 600 600 600
1980 1980 1980 1980 1980165 270 290 355 43545,5 49,0 50,0 52,0 53,5
IDEN
TIFIC
ATIO
NClose control air conditioners withDisplacement air delivery
SynergyThe Heat Hunter system can be used to increase the capacity of existing plants, in perfect synergy
with traditional machines.
HEAT HUNTER.CWChilled water feeding air conditioning units, suitable for hi-tech. facilities applications and and telecom exchanges.
Displacement mode air delivery for air distribution directly into the room.
59RC GROUP SpA • General Catalogue • 155.EN.0504
CHAR
ACTE
RIST
ICSBase in aluminium profile frame painted •
with epoxy powders, galvanized steel
inner frame and galvanized steel sheet
panels externally coated with PVC film
Inverter controlled centrifugal fans •
directly driven by electric motor
2 way proportional valve with •
emergency manual control
for variable water flow plant
Microprocessor control system •
Electric board in separated •
technical compartment
Door lock main switch •
RS485 serial line •
Remote air cooled condenser •
Proportional electric heater •
Humidification and dehumidification •
Direct Free-Cooling system •
Condensate discharge pump •
High efficiency filters •
Remote temperature sensor •
OPTI
ONAL
HEAT HUNTER.CW10 ÷ 65 kW
The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.
HIGH
LIGHT
S
EfficientFlowProprietary energy saving
system based on the fans
speed modulation according
to the real room load
conditions, the whole applied
to displacement technology.
SideBySideUnits are designed to be installed side by side to obtain a sort
of “Cold Wall” of any length.
SolutionHeat Hunter, in combination with our free-cooling Maximo
Optimizer chillers, forms the proprietary SOLUTION system, to
maximise the energy saving in the presence of variable flow-
rate technological plants.
60 RC GROUP SpA • General Catalogue • 155.EN.0504
FLEXICLIM SYSTEM
Flexiclim, which is internationally patented and guaranteed by a huge number of important references both in Italy and abroad, isa flexible air distribution system and it is particularly suitable for those plants located in buildings where the inner air distributioncan be modified as the internal layout is revised, ie open space in offices or call centres, exposition rooms or museums areas fortemporary exhibitions. The air is treated by specific chilled water air conditioners with upflow or downflow air delivery. The
units are connected through flexible ducts to terminal distribution units with variable air flow. The great pro of this system is thepossibility to easily and rapidly move the terminal unit in order to meet the room changing needs (desks position, increase of desksnumber, expositive windows position, exposed works of art position). Installation rapidity and the possibility of primary air make thesystem very competitive in comparison with traditional primary air plants.
PLAN
T TY
PEFlexiclim System
61RC GROUP SpA • General Catalogue • 155.EN.0504
INDE
X FLEXICLIM - FLEXIOVER.CW.O • 16 ÷ 48 kWChilled water air conditioning system for offices and hi-tech facilities.
FLEXICLIM - FLEXIUNDER.CW.U • 16 ÷ 48 kWChilled water air conditioning system for offices and hi-tech facilities.
62 FLEXICLIM SYSTEM
64
Flexiclim System
62 RC GROUP SpA • General Catalogue • 155.EN.0504
PureAirSystem conceived to connect the local units to the terminal units in order to grant pure air in the
conditioned spaces, with no dependence from the maintenance status of the false ceiling.
FLEXIOVER.CW.O - MODELSizeCooling capacity (1) kWCooling capacity (2) kWAir flow m3/hAir delivery circular connections
For G1 terminals n. x ØFor G2 terminals n. x Ø
Dimensions Length mmDepth mmHeight mm
Net weight kgNoise pressure level (3) dB(A)
FLEXIBOX - MODELAir flow m3/hDimensions Length mm
Depth mmHeight mm
Net weight kgNoise pressure level (4) dB(A)
(1) Characteristics referred to air inlet at 24°C with 50% rH; chilled water inlet at 7°C.(2) Characteristics referred to air inlet at 27°C with 47% rH; chilled water inlet at 7°C.(3) Noise pressure 1m far from the unit in free field conditions with ducted air distribution.(4) NR values (Noise rating) referred to room sound absorption 20m2 Sabine; directivity factor Q=2.POWER SUPPLY: 400.3.50+Mp
21 33 50Z1 Z2 Z315 23,8 36,1
20,1 32,1 48,43150 5200 7500
6 x 145 11 x 145 14 x 1455 x 195 8 x 195 12 x 1951245 1595 2500645 645 645
1930 1930 1930280 370 53040 42 45
G1 G2150 ÷ 500 200 ÷ 800
500 500500 500180 2507 8
29 ÷ 39 34 ÷ 44
TECH
NICA
L DAT
AFlexiclim System - OVER
IDEN
TIFIC
ATIO
N
Patent
FLEXICLIM®.CW.OFlexible chilled water feeding air conditioning system, suitable for hi-tech. facilities applications, offices and call
centres with false ceiling. Air intake/delivery from the top.
63RC GROUP SpA • General Catalogue • 155.EN.0504
CHAR
ACTE
RIST
ICSHousing with aluminium profile frame •
with galvanized steel sheet panels
externally coated with PVC film
Sandwich panels •
Centrifugal fans directly driven •
by electric motor
Fans speed manual regulation •
Microprocessor control system •
Electric board in separated •
technical compartment
Door lock main switch •
Two configurations are available •
“M” configuration with single coil
“T” configuration with double coils
RS485 serial line •
Remote control board •
Electric heating •
Humidification and dehumidification •
Air delivery plenum •
Disposable air filters •
OPTI
ONAL
FLEXIOVER - FLEXICLIM.CW.O15 ÷ 48 kW
The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.
RC GROUP
MP2000
FlexiBoxLocal terminal cassettes; the
passive ventilation system
totally eliminates the noise
problem and the standard
maintenance need.
Flexiclim - Flexiover System
HIGH
LIGHT
S
64 RC GROUP SpA • General Catalogue • 155.EN.0504
FLEXIUNDER.CW.U - MODELSizeCooling capacity (1) kWCooling capacity (2) kWAir flow m3/hAir delivery circular connections
For G1 terminals n. x ØFor G2 terminals n. x Ø
Dimensions Length mmDepth mmHeight mm
Net weight kgNoise pressure level (3) dB(A)
FLEXIBOX - MODELAir flow m3/hDimensions Length mm
Depth mmHeight mm
Net weight kgNoise pressure level (4) dB(A)
21 33 50Z1 Z2 Z315 23,8 36,1
20,1 32,1 48,43150 5200 7500
6 x 145 11 x 145 14 x 1455 x 195 8 x 195 12 x 1951245 1595 2500645 645 6451930 1930 1930280 370 53040 42 45
G1 G2150 ÷ 500 200 ÷ 800
500 500500 500180 2507 8
29 ÷ 39 34 ÷ 44
(1) Characteristics referred to air inlet at 24°C with 50% rH; chilled water inlet at 7°C.(2) Characteristics referred to air inlet at 27°C with 47% rH; chilled water inlet at 7°C.(3) Noise pressure 1m far from the unit in free field conditions with under floor air distribution.(4) NR values (Noise rating) referred to room sound absorption 20m2 Sabine; directivity factor Q=2.POWER SUPPLY: 400.3.50+Mp
TECH
NICA
L DAT
AFlexiclim System - UNDER
EasyFitThanks to EASY FIT system it is not necessary to create air delivery and intake areas in the raised
floor; the repositioning of FlexiBox cassettes due to new space needs doesn’t require either specialized
technicians intervention or plant or floor modifications.
IDEN
TIFIC
ATIO
N
Patent
FLEXICLIM®.CW.UFlexible chilled water feeding air conditioning system, suitable for hi-tech. facilities applications, offices and call
centres with raised floor. Air intake/delivery from the bottom.
65RC GROUP SpA • General Catalogue • 155.EN.0504
CHAR
ACTE
RIST
ICSHousing with aluminium profile frame •
with galvanized steel sheet panels
externally coated with PVC film
Sandwich panels •
Centrifugal fans directly driven •
by electric motor
Fans speed manual regulation •
Microprocessor control system •
Electric board in separated •
technical compartment
Door lock main switch •
Two configurations are available •
“M” configuration with single coil
“T” configuration with double coils
RS485 serial line •
Remote control board •
Electric heating •
Humidification and dehumidification •
Disposable air filters •
OPTI
ONAL
FLEXIUNDER - FLEXICLIM.CW.U15 ÷ 48 kW
The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.
Flexiclim system is
internationally
patented and won the
reward for innovation
INTERCLIMA 1993.
RC GROUP
MP2000
Flexiclim - Flexiunder System
HIGH
LIGHT
S
66 RC GROUP SpA • General Catalogue • 155.EN.0504
HEAT PUMP UNITSClose control air conditioning reliability applied to “Comfort” all year long. Available up to a capacity reaching 86 kW, heat pumpair conditioning units are particularly suitable for low and medium installations, where the compactness of the units and theirsimple installation are fundamental requirements. They are available both with remote air cooled condenser and in packagedversion with built-in water cooled condenser.Equipped with Scroll type compressors, characterized by high efficiency and low noise, RC GROUP air conditioning units stand out
for construction care, the high reliability and the extreme installation flexibility, thanks to a wide range of optional extras that havebeen conceived to satisfy all demands.
PLAN
T TY
PEHeat pump air conditioners
67RC GROUP SpA • General Catalogue • 155.EN.0504
INDE
X PEGASUS.DX.A.P.O • R407C • 6 ÷ 86 kWHeat pump air conditioners (air cooled).
PEGASUS.DX.W.P.O • R407C • 6 ÷ 39 kWHeat pump air conditioners (water cooled).
68 HEAT PUMP VERSION
70
Heat pump air conditioners
68 RC GROUP SpA • General Catalogue • 155.EN.0504
PEGASUS.DX.A.P.O - MODELSizeCooling capacity (1) kWHeating capacity (2) kWAir flow m3/hCompressors n.Dimensions Length mm
Depth mmHeight mm
Net weight kgNoise pressure level (3) dB(A)
PEGASUS.DX.A.P.O - MODELSizeCooling capacity (1) kWHeating capacity (2) kWAir flow m3/hCompressors n.Dimensions Length mm
Depth mmHeight mm
Net weight kgNoise pressure level (3) dB(A)
5.Z1 7.Z1 10.Z1 15.Z1 18.Z1 20.Z1 24.Z2S0 S0 S1 S1 S2 S4 S56,3 7,4 11,4 15,3 18 21,8 25,65,7 6,7 10,3 14,2 16,5 19,4 22,1
1580 1580 3150 3150 3640 5570 60001 1 1 1 1 1 2
645 645 645 645 755 1105 1125410 410 645 645 645 645 860
1680 1680 1930 1930 1930 1930 1950145 150 205 210 235 265 38051,5 51,5 52 52 54 54,5 55,6
30.Z2 36.Z2 40.Z2 52.Z2 60.Z2 74.Z2 88.Z2S5 S6 S7 S8 S9 S9 S9
29,2 35,9 40,2 52,5 63 76,2 8626,7 33 35,6 45,8 53,5 73,7 83,96000 8200 10400 13500 17000 17000 17000
2 2 2 2 2 2 21125 1360 1750 2210 2680 2680 2680860 860 860 860 860 860 860
1950 1950 1950 1950 1950 1950 1950385 460 615 840 1000 1020 105055,6 58 59 60 62,5 62,5 62,5
(1) Characteristics referred to evaporator air inlet at 27°C with 47% rH; condenser air inlet at 35°C.(2) Characteristics referred to air inlet at 20°C, outdoor air at 7°C with 87% rH.(3) Noise pressure 1m far from the unit in free field conditions with ducted air distribution.POWER SUPPLY: 230.1.50 for models 5.Z.1 and 7.Z.1 • 400.3.50+Mp for other models
Heat pump air conditionersTE
CHNI
CAL D
ATA
DNA@RCThe large capacity precision air conditioning reliability transferred to “Comfort”
applications all year long.
PEGASUS.DX.A.P.OHeat pump air conditioning units with remote air cooled condenser suitable for comfort applications.
Ductable air flow delivery from the top or direct delivery into the room through a plenum device.
IDEN
TIFIC
ATIO
N
69RC GROUP SpA • General Catalogue • 155.EN.0504
CHAR
ACTE
RIST
ICSHousing with aluminium profile frame •
with galvanized steel sheet panels
externally coated with PVC film
R407C refrigerant charge •
Scroll type compressors •
Centrifugal fans directly driven •
by electric motor
Microprocessor control system •
Electric board in separated •
technical compartment
Door lock main switch •
Cooling connections through •
Rotalock valves
RS485 serial line •
Remote control board •
Remote air cooled condenser •
Electric or hot water heating •
Drive system fans •
Humidification •
Compressors capacity control •
Double cooling circuit unit •
Air delivery plenum •
Double expansion valve system •
High efficiency air filters •
OPTI
ONAL
PEGASUS.DX.A.P.OR407C • 6 ÷ 109 kW
The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.
MateSystemAir cooled condensers specially
designed to work coupled with
heat pump units version with
direct control by the
microprocessor mounted on the
unit.
QuickStartThe supply includes whatever is
needed for a correct unit
working. For the start-up the
units only need electrical,
hydraulic and cooling
connections for a complete
installation in compliance with all
the current norms.
SpaceSaverInternal components lay-out to
carry out all inspection and
maintenance operations from the
front of the unit, with no use of
side spaces.
HIGH
LIGHT
S
70 RC GROUP SpA • General Catalogue • 155.EN.0504
PEGASUS.DX.W.P.O - MODELSizeCooling capacity (1) kWHeating capacity (2) kWAir flow m3/hCompressors n.Dimensions Length mm
Depth mmHeight mm
Net weight kgNoise pressure level (3) dB(A)
5.Z1 7.Z1 10.Z1 15.Z1 18.Z1 20.Z1 24.Z2 30.Z2 36.Z2S0 S0 S1 S1 S2 S4 S5 S5 S66,6 7,98 12,2 16,7 19,9 23,6 28,5 32 396,2 7,5 10,5 15,7 18,7 22,2 26,3 30,6 36,8
1580 1580 3150 3150 3640 5570 6000 6000 82001 1 1 1 1 1 2 2 2
645 645 645 645 755 1105 1125 1125 1360410 410 645 645 645 645 860 860 860
1680 1680 1930 1930 1930 1930 1950 1950 1950160 165 205 220 250 275 395 400 47551,5 51,5 52 52 54 54,5 55,6 55,6 58
(1) Characteristics referred to evaporator air inlet at 27°C with 47% rH; condenser water inlet at 30°C.(2) Characteristics referred to air inlet at 20°C entering water to gas/water heat exchanger at 15°C.(3) Noise pressure 1m far from the unit in free field conditions with ducted air distribution.POWER SUPPLY: 230.1.50 for models 5.Z.1 and 7.Z.1 • 400.3.50+Mp for other models
Heat pump air conditionersTE
CHNI
CAL D
ATA
AdaptiveRangeA wide range of models and optional conceived to satisfy specific installation needs in terms of
capacity, filtering and ventilation.
PEGASUS.DX.W.P.OHeat pump air conditioning units with built-in water cooled condenser suitable for comfort applications.
Ductable air flow delivery from the top or direct delivery into the room through a plenum device.
IDEN
TIFIC
ATIO
N
71RC GROUP SpA • General Catalogue • 155.EN.0504
CHAR
ACTE
RIST
ICSHousing with aluminium profile frame •
with galvanized steel sheet panels
externally coated with PVC film
R407C refrigerant charge •
Scroll type compressors •
Centrifugal fans directly driven •
by electric motor
Microprocessor control system •
Built-in water cooled condenser •
Electric board in separated •
technical compartment
Door lock main switch •
RS485 serial line •
Remote control board •
Electric or hot water heating •
Drive system fans •
Humidification •
Compressors capacity control •
Double cooling circuit unit •
Air delivery plenum •
High efficiency air filters •
OPTI
ONAL
PEGASUS.DX.W.P.OR407C • 6 ÷ 39 kW
The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.
PerformancePlusTandem SCROLL type
compressors to grant
the maximum energy
efficiency in any working
condition.
SmartLinkSystem conceived for the
creation of a Local Area Network
(LAN), with unit rotation and
stand-by management, without
any supplementary components.
RCProactiveMP2000 control and
monitoring system
technology owned by RC
PROACTIVE, conceived to
grant continuous operation
even in emergency
situations.
HIGH
LIGHT
S
72 RC GROUP SpA • General Catalogue• 155.EN.0504
AIR CONDITIONING SYSTEM WITH UPFLOW AIR DELIVERY (OVER)It is the system traditionally used in the air conditioning field. The air distribution is from the top of the unit through a plenum deviceor through supply ducts in the case of false ceiling.The air is injected into the room at a low temperature but at high speed in correspondence to the corridors between the differentracks rows. The cold air moves from the top to the bottom with a turbulent flow, mixing with the hot air outgoing from the racks.By this mixing effect the temperature of the air entering the racks is higher than the a/c unit leaving air temperature.
The air flow in each area is predetermined during the design stage and it is not dependent on the actual state of the load to be dissipated.The system can be applied in those plants having low/medium room thermal loads density, such as old systems, but it might be not suitablein the last IT and TLC plants, where the single thermal loads are very high.
FREE-COOLING PROPORTIONAL SYSTEMFor a further energy-saving, the RC GROUP conditioners are equipped with a proportional automatic free-cooling system in order toobtain free cooling when the indoor temperature is higher than outdoor one.Practically the fresh air is used as a refrigerant in order to cool the ambient, when the outside conditions allow it.The cooling system is totally proportional and allows three working modes:- total free-cooling: only fresh air is used to cool the ambient;- partial free-cooling: the fresh air is used for a pre-cooling and the compressor or the chilled water are used to balance the load;- mechanical cooling: the compressor or the chilled water are used to cool the ambient.
PLAN
T TY
PEAir conditioners for information technologyand communication
73RC GROUP SpA • General Catalogue• 155.EN.0504
INDE
X MINIPAC.DX.A • R407C • 4 ÷ 19kWPackaged outdoor air conditioners for shelter
and telephone exchanges.
ENERTEL.DX.A.O • R407C • 5 ÷ 15 kWPackaged air conditioners for hi-tech. facilities
and telephone exchanges.
ENERGY.SPLIT.DX.A • R407C • 4 ÷ 15 kWSplit-system air conditioners for hi-tech. facilities
and telephone exchanges.
74 OVER VERSION
76
78
Air conditioners for informationtechnology and communication
74 RC GROUP SpA • General Catalogue• 155.EN.0504
MINIPAC.DX.A - MODELSizeCooling capacity (1) kWAir flow m3/hCompressors n.Dimensions Length mm
Depth mmHeight mm
Net weight kgNoise pressure level (2) dB(A)
MINIPAC.DX.A - MODELSizeCooling capacity (1) kWAir flow m3/hCompressors n.Dimensions Length mm
Depth mmHeight mm
Net weight kgNoise pressure level (2) dB(A)
4.R1 5.R1 6.Z1 8.Z1 9.Z1S0 S1 S1 S1/S S1/S4,2 5,2 6 8,3 9,1
1100 1750 1750 2200 22001 1 1 1 1
660 831 831 902 902548 583 583 668 668
1303 1500 1500 1758 1758135 155 165 195 20054 52 57 57 62
11.Z1 13.Z1 16.Z1 20.Z1S2 S2 S3 S3
11,2 12,1 16,2 19,33200 3700 4300 5000
1 1 1 11000 1000 1000 1000700 700 700 700
2004 2004 2352 2352220 235 270 29058 58 58 64
(1) Characteristics referred to evaporator air inlet at 27°C with 42% rH; condenser air inlet at 35°C.(2) Noise pressure 1m far from the unit in free filed conditions.POWER SUPPLY: 230.1.50 from model 4.Z1 to model 9.Z1
400.3.50+N from model 11.Z1 to model 20.Z1
TECH
NICA
L DAT
A
Made2LastHousing designed to last in time and in bad weather.
MINIPAC.DX.A.OOutdoor air cooled packaged air conditioning unit suitable for telecom exchanges and shelters.
Horizontal air flow delivery for direct room distribution.
Air conditioners for information technologyand communication - OVER
IDEN
TIFIC
ATIO
N
75RC GROUP SpA • General Catalogue• 155.EN.0504
CHAR
ACTE
RIST
ICSAluminium supporting housing •
Proportional free-cooling system •
R407C refrigerant charge •
Scroll or Rotative compressor •
Centrifugal fans •
Microprocessor control system •
Feeding voltage: •
Network + UPS at 230 Vac
Network + UPS at 48 Vdc
Built-in air cooled condenser •
Proportional condensing control •
RS485 serial line •
Remote control board •
Clogged filters alarm •
Room humidity sensor •
Electric heater •
LN function •
Mounting brackets kit •
OPTI
ONAL
MINIPAC.DX.AR407C • 4 ÷ 19 kW
The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.
TwinPowerDouble feeding voltage
system, network + UPS,
conceived to grant
working continuity even
during black-out periods.
Easy@ServeAll regulation and control
components are easily
accessible.
RCProactiveMP2000 control and management
system, with RC PROACTIVE
proprietary technology, conceived to
grant continuity of work even in
emergency situations.
HIGH
LIGHT
S
76 RC GROUP SpA • General Catalogue• 155.EN.0504
ENERTEL.DX.C.O - MODELSizeCooling capacity (1) kWAir flow m3/hCompressors n.Dimensions Length mm
Depth mmHeight mm
Net weight kgNoise pressure level (2) dB(A)
ENERTEL.DX.C.O - MODELSizeCooling capacity (1) kWAir flow m3/hCompressors n.Dimensions Length mm
Depth mmHeight mm
Net weight kgNoise pressure level (2) dB(A)
5.Z1 6.Z1 7.Z1S1 S1 S15,1 5,7 6,7
1700 1700 17001 1 1
650 650 650650 650 650
2000 2000 2000215 220 23560 60 60
8.Z1 10.Z1 11.Z1 13.Z1 15.Z1S2 S2 S2 S3 S39,2 10,4 11,5 13,3 14,6
3000 3000 3000 3400 34001 1 1 1 1
990 990 990 1190 1190650 650 650 650 650
2000 2000 2000 2000 2000320 330 340 390 40063 63 63 63 63
(1) Characteristics referred to evaporator air inlet at 27°C with 42% rH; condenser air inlet at 35°C.(2) Noise pressure 1m far from the unit in free filed conditions.POWER SUPPLY: 230.1.50 from model 5.Z1 to model 7.Z1
400.3.50+N from model 8.Z1 to model 15.Z1
TECH
NICA
L DAT
A
AdaptiveRangeA wide range of models and optional conceived to satisfy specific capacity, filtering, ventilation and plant needs.
ENERTEL.DX.A.OAir cooled packaged air conditioning unit suitable for telecom exchanges and hi-tech. facilities.
Ductable upflow air delivery or direct room distribution through a built-in plenum device.
Air conditioners for information technologyand communication - OVER
IDEN
TIFIC
ATIO
N
77RC GROUP SpA • General Catalogue• 155.EN.0504
CHAR
ACTE
RIST
ICSHousing with aluminium profile frame •
with galvanized steel sheet panels
externally coated with PVC film
Free-cooling proportional system •
R407C refrigerant charge •
Scroll type compressor •
Centrifugal fans •
Microprocessor control system •
Feeding voltage: •
Network + UPS a 230 Vac
Network + UPS a 48 Vdc
Built-in air cooled condenser •
Proportional condensing control •
RS485 serial line •
Remote control board •
Clogged filters alarm •
Room humidity sensor •
Electric heater •
LN function •
Fresh air kit for air suction •
and outdoor air discharge
OPTI
ONAL
ENERTEL.DX.A.OR407C • 5 ÷ 15 kW
The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001certified.
EMCAll RC products are in
compliance with the norms
about electromagnetic
suitability.
QuickStartThe supply includes
whatever is needed for a
correct unit working.
For the start-up the units
only need electrical and
hydraulic connections for
a complete installation in
compliance with all the
current norms.
SmartLinkSystem conceived for the creation of a
Local Area Network (LAN), with unit
rotation and stand-by management,
without any supplementary components.
HIGH
LIGHT
S
78 RC GROUP SpA • General Catalogue• 155.EN.0504
INDOOR EVAPORATING UNITENERGY.SPLIT.DX.A - MODELSizeCooling capacity (1) kWAir flow m3/hDimensions Length mm
Depth mmHeight mm
Net weight kgNoise pressure level (2) dB(A)
OUTDOOR CONDENSING UNITENERGY.SPLIT.DX.A - MODELCompressors n.Dimensions Length mm
Depth mmHeight mm
Net weight kgNoise pressure level (2) dB(A)
4.R1 5.R1 6.Z1 7.Z1 8.Z1 10.Z1 13.Z1 15.Z1S0 S0 S0 S1 S1 S1 S2 S24 5,1 5,7 6,5 7,9 10,1 12,3 14,7
1400 1400 1400 2000 2000 2000 3900 39001132 1132 1132 1293 1293 1293 1293 1293834 834 834 980 980 980 1380 1380290 290 290 357 357 357 357 357442 45 45 80 80 80 103 10355 55 55 54 54 61 65 65
4.R1 5.R1 6.Z1 7.Z1 8.Z1 10.Z1 13.Z1 15.Z11 1 1 1 1 1 1 1
852 852 1048 1048 1048 1305 1305 1305460 460 460 460 460 580 580 580610 610 830 830 830 900 900 90055 65 70 70 75 95 98 10555 55 53 53 57 57 57 58
(1) Characteristics referred to evaporator air inlet at 27°C with 42% rH; condenser air inlet at 35°C.(2) Noise pressure 1m far from the unit in free filed conditions.POWER SUPPLY: Indoor evaporating unit : 230.1.50
Outdoor condensing unit: 230.1.50 from model 4.R1 to model 8.Z1 included400.3.50+N from model 10.Z1 to model 15.Z1
TECH
NICA
L DAT
A
SpaceSaverComponents inner arrangement to carry out all inspection and maintenance operations from the
front of the unit, with no use of side spaces.
ENERGY.SPLIT.DX.A.OSplit-system air conditioning units for telecom exchanges and hi-tech. facilities
Horizontal air flow delivery for direct room distribution through a built-in plenum device.
Air conditioners for information technologyand communication - OVER
IDEN
TIFIC
ATIO
N
79RC GROUP SpA • General Catalogue• 155.EN.0504
CHAR
ACTE
RIST
ICSHousing with aluminium profile frame •
with galvanized steel sheet panels
externally coated with PVC film
Free-cooling proportional system •
R407C refrigerant charge •
Scroll type compressor •
Centrifugal fans •
Microprocessor control system •
Feeding voltage: •
Network + UPS at 230 Vac
Network + UPS at 48 Vdc
Built-in air cooled condenser •
Proportional condensing control •
RS485 serial line •
Clogged filters alarm •
Room humidity sensor •
Electric heater •
LN function •
Fresh air kit for air suction •
and outdoor air discharge
OPTI
ONAL
ENERGY.SPLIT.DX.AR407C • 4 ÷ 15 kW
The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001certified.
SleepWellProprietary Software for
unit working with the
lowest noise emission
during the night.
MateMATE integrated condensing control
system for a continuous speed
modulation of condensers fans.
DirectCoolProportional system for direct
free-cooling, completely
controlled by the
microprocessor, for an extreme
reduction of compressor
working hours and a high
energy costs saving.
HIGH
LIGHT
S
80 RC GROUP SpA • General Catalogue• 155.EN.0504
AIR CONDITIONING SYSTEM WITH DISPLACEMENT MODE AIR DELIVERY (DISPLACEMENT)The basic concept of the air conditioning system with displacement air delivery is based on the natural convection principle, wherethe cold air is at the lower ambient zones, while the hot air is at the higher ones. This concept has been developed and applied byRC GROUP for the air conditioning in Telephone Exchangers and Hi-Tech. facilities.The modern Telecom devices have the aim of heat dissipation by air suction from the lower side close to the floor, for dischargefrom the top side. The air circulation inside the Telecom device can be in natural convenction mode or through internal fans.The RC GROUP free-cooling air conditioning system with displacement air delivery supplies the cold air directly into the room close
to the floor with low air speed and intakes the air from the top side of the conditioner where the air temperature is higher.Therefore, the Telecom devices (to be cooled) intakes the cold air from the bottom and discharges the hot air from the top.The system and the extremely low air speed, cause a high air stratification with 10°C temperature difference between the coldest andthe hottest zone.By hot air suction in the higher ambient zone, the air conditioner remarkably increases both the thermodynamic performance and theefficiency, with consequent working conditions and energy consumption optimization.
CONVERSION OF DISPLACEMENT UNITS INTO DOWNFLOW AIR DELIVERY AIR CONDITIONING UNITS FOR AIR DISTRIBUTIONTHROUGH DOUBLE FLOOR (UNDER)“Kit under” optional allows the conversion of the Displacement units into Under air conditioning units.The air distribution is from the bottom by means of the plenum formed between the building floor and the raised floor. The air can be directlyinjected into the racks if these are opened at the bottom and properly sealed, in order to avoid any possible leakage in the environment.The cold air flows through each apparatus, cooling the electronic equipment.The air flow moves upwards, enters the bottom part of the apparatus and leaves from the top. The air conditioners is provided with anair inlet from the top, for air intake from the warmest area in the room improving the plant energy performances. The system preventsa strong mixture of the cold air injected into the room and the hot air coming from the racks, typical of upflow air conditioners. This solutionis most favourable when the thermal load is uniformly distributed in all areas of the room. If the load distribution is not homogeneous,the position of the grilles and of the air outlet nozzles will have to be suitable to the existing load needs.The air conditioning unit draws the air to be cooled at a temperature higher than the one measured around the equipment to be cooled,obtaining higher thermodynamic performances. The air can also be distributed through grilles on the raised floor, in front of the racksrows. In this case the cold air is injected into the room near the equipment to be cooled; the equipment can draw autonomously thenecessary cooling air.
FREE-COOLING PROPORTIONAL SYSTEMFor a further energy-saving, the RC GROUP conditioners are equipped with a proportional automatic free-cooling system in order toobtain free cooling when the indoor temperature is higher than outdoor one.Practically the fresh air is used as a refrigerant in order to cool the ambient, when the outside conditions allow it.- total free-cooling: only fresh air is used to cool the ambient;- partial free-cooling: the fresh air is used for a pre-cooling and the compressor or the chilled water are used to balance the load;- mechanical cooling: the compressor or the chilled water are used to cool the ambient.The outdoor air introduction into the room causes an increase of the inner pressure which must be avoided to grant a correct plant work.Therefore on ENERGY.SPLIT and PEGASUS units it is necessary to install an overpressure damper near the ceiling to allow the exceedinghot air discharge outdoor.On the contrary on packaged units it is not necessary to install the damper because the air is directly discharged by the unit.
PLAN
T TY
PEAir conditioners for information technologyand communication - DISPLACEMENT
81RC GROUP SpA • General Catalogue• 155.EN.0504
INDE
X ENERTEL.DX.A.DL • R134a • 6 ÷ 15 kWPackaged air conditioning units for hi-tech. facilities and telecom
exchanges.
PEGASUS.DX.A.DL • R407C • 5 ÷ 25 kWAir conditioning units with remote air cooled condenser for hi-tech.
facilities and telecom exchanges.
PEGASUS.CW.DL • 9 ÷ 55 kWChilled water feeding air conditioning units for hi-tech. facilities and
telecom exchanges.
86 DISPLACEMENT VERSION
88
90
Air conditioning units for informationtechnology and communication
82 RC GROUP SpA • General Catalogue• 155.EN.0504
ENERTEL.DX.C.DL - MODELSizeCooling capacity (1) kWAir flow m3/hCompressors n.Dimensions Length mm
Depth mmHeight mm
Net weight kgNoise pressure level (2) dB(A)
ENERTEL.DX.C.DL - MODELSizeCooling capacity (1) kWAir flow m3/hCompressors n.Dimensions Length mm
Depth mmHeight mm
Net weight kgNoise pressure level (2) dB(A)
6.Z1 7.Z1 8.Z1S1 S1 S16,6 7,3 7,8
1850 1850 18501 1 1
750 750 750625 625 6252250 2250 2250215 230 24057 57 57
9.Z1 10.Z1 13.Z1 15.Z1S2 S2 S3 S39,9 10,9 14,6 15,5
2400 2400 3800 38001 1 1 1
950 950 1200 1200625 625 625 6252250 2250 2250 2250320 320 380 39055 55 61 61
(1) Performance referred to room conditions at 1m from floor at 24°C with 50% rH, deriving from the air conditioner air temperature inlet at 30°C with 35% rH;condenser air inlet at 35°C.
(2) Noise pressure 1m far from the unit in free filed conditions.POWER SUPPLY: 230.1.50 from model 6.Z1 to model 8.Z1
400.3.50+N from model 9.Z1 to model 15.Z1
TECH
NICA
L DAT
A
DisplacementAir intake system at lowest speed to exploit the displacement air conditioning technology.
ENERTEL.DX.A.DLAir cooled packaged air conditioning units suitable for hi-tech. facilities and telecom exchanges.
Air flow from the front or from the side through a grille for displacement air distribution.
Thanks to “kit under” optional it is possible to convert the unit into a downflow air conditioning unit (under).
Air conditioners for information technologyand communication - DISPLACEMENT
IDEN
TIFIC
ATIO
N
83RC GROUP SpA • General Catalogue• 155.EN.0504
CHAR
ACTE
RIST
ICSHousing with aluminium profile frame •
with galvanized steel sheet panels
externally coated with PVC film
Free-cooling proportional system •
R134a refrigerant charge •
Scroll type compressor •
Centrifugal fans •
Microprocessor control system •
Feeding voltage: •
Network + UPS at 230 Vac
Network + UPS at 48 Vdc
Built-in air cooled condenser •
Proportional condensing control •
RS485 serial line •
Remote control board •
Clogged filters alarm •
Room humidity sensor •
Electric heater •
Fresh air kit for air suction •
and outdoor air discharge
Kit Under for unit conversion in •
downflow air conditioning unit
OPTI
ONAL
ENERTEL.DX.A.DLR134a • 6 ÷ 15 kW
The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001certified.
SpaceSaverDisplacement system
eliminates the need for
interspaces and ducts for the
correct air distribution inside
the rack.
DirectCoolProportional system for
direct free-cooling,
completely controlled by
the microprocessor, for an
extreme reduction of
compressor working
hours and a high energy
costs saving.
RCProactiveMP2000 control and management
system technology owned by RC
PROACTIVE, conceived to grant
continuity of work even in
emergency situations.
HIGH
LIGHT
S
84 RC GROUP SpA • General Catalogue• 155.EN.0504
AIR CONDITIONERSPEGASUS.DX.A.DL - MODELSizeCooling capacity (1) kWAir flow m3/hCompressors n.Dimensions Length mm
Depth mmHeight mm
Net weight kgNoise pressure level (2) dB(A)
REMOTE AIR COOLED CONDENSERTEAM.MATE.DX.A - MODELAir flow m3/hDimensions Length mm
Depth mmHeight mm
Net weight kgNoise pressure level (3) dB(A)
5.Z1 7.Z1 10.Z1 13.Z1 15.Z1 18.Z1 22.Z1 25.Z1S2 S2 S2 S4 S4 S4 S7/S S7/S5,9 7,6 10,6 13,5 16 18,4 23,1 26,3
1700 2150 2450 4000 4650 4650 6300 72501 1 1 1 1 1 1 1
755 755 755 1105 1105 1105 1720 1720645 645 645 645 645 645 645 6451930 1930 1930 1930 1930 1930 1930 1930220 225 235 260 265 270 375 38553 55 57 57 59 59 59 61
M.10 M.10 M.18 M.18 M.18 M.22 M.31 M.313400 3400 4400 4400 4400 5600 10100 10100850 850 850 850 850 1150 1350 150482 482 482 482 482 482 620 620726 726 726 726 726 726 1026 102631 31 37 37 37 47 95 95
29,3 29,3 31,3 31,3 31,3 30,3 39,3 39,3
(1) Performance referred to room conditions at 1m from floor at 24°C with 50% rH, deriving from the air conditioner air temperature inlet at 30°C with 35% rH;condenser air inlet at 35°C.
(2) Noise pressure 1m far from the unit in free filed conditions.(3) Noise pressure 10m far from the unit in free filed conditions, condensing coils side.POWER SUPPLY: 230.1.50 from model 5.Z1 to model 8.Z1
400.3.50+N from model 10.Z1 to model 25.Z1
TECH
NICA
L DAT
A
SpaceSaverDisplacement system eliminates the need for interspaces and ducts for the correct air distribution inside the rack.
PEGASUS.DX.A.DLDirect expansion air conditioning units with remote air cooled condenser suitable for hi-tech. facilities and telecom
exchanges. Air flow from the front or from the side through a grille for displacement air distribution. Thanks to
“kit under” optional it is possible to convert the unit into a downflow air conditioning unit (under).
Air conditioners for information technologyand communication - DISPLACEMENT
IDEN
TIFIC
ATIO
N
85RC GROUP SpA • General Catalogue• 155.EN.0504
CHAR
ACTE
RIST
ICSHousing with aluminium profile frame •
with galvanized steel sheet panels
externally coated with PVC film
Free-cooling proportional system •
R407C refrigerant charge •
Scroll type compressor •
Centrifugal fans •
Microprocessor control system •
Feeding voltage: •
Network + UPS at 230 Vac
Network + UPS at 48 Vdc
Remote air cooled condenser •
Proportional condensing control •
RS485 serial line •
Remote control board •
Clogged filters alarm •
Room humidity sensor •
Electric heater •
Fresh air kit for air suction •
and outdoor air discharge
Kit Under for unit conversion in •
downflow air conditioning unit
OPTI
ONAL
PEGASUS.DX.A.DLR134a • 5 ÷ 25 kW
The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001certified.
MateMATE Integrated condensing control
system for a continuous speed
modulation of condensers fans.
QuickStartThe supply includes whatever is needed
for a correct unit working.
For the start-up the units only need
electrical, hydraulic and cooling
connections for a complete installation in
compliance with all the current norms.
Easy@ServeAll regulation and control components are
easily accessible from the front of the unit.
HIGH
LIGHT
S
86 RC GROUP SpA • General Catalogue• 155.EN.0504
PEGASUS.CW.DL - MODELSizeCooling capacity (1) kWCooling capacity (2) kWAir flow m3/hDimensions Length mm
Depth mmHeight mm
Net weight kgNoise pressure level (3) dB(A)
8 11 22 35 48S2/S S2 S4 S7/S S8/S11,4 15 28,8 45,7 61,58,3 11,2 21,3 33,6 45,3
1500 2450 4650 7250 9800755 755 1105 1720 2180645 645 645 645 6451930 1930 1930 1930 1930175 180 200 295 37048 54 56,5 58 59
(1) Performance referred to room conditions at 1m from floor at 24°C with 50% rH, deriving from the air conditioner air temperature inlet at 30°C with 35% rH; chilled water inlet at 7°C.(2) Performance referred to room conditions at 1m from floor at 24°C with 50% rH, deriving from the air conditioner air temperature inlet at 30°C with 35% rH; chilled water inlet at 10°C.(3) Noise pressure 1m far from the unit in free filed conditions.POWER SUPPLY:The units in only cooling version are directly supplied by the UPS system at 230 Vac or 48VdcFor the units in cooling + heating version it is necessary to connect also the 400.3.50+N network supply.
TECH
NICA
L DAT
A
PerformancePlusDisplacement air distribution system grants an optimal temperatures stratification in the room
assuring the maximum possible thermodynamic efficiency in every situation.
PEGASUS.CW.DLChilled water feeding air conditioning unit suitable for hi-tech. facilities or telecom exchanges.
Air flow from the front and from the side through a grille for displacement air distribution.
Thanks to “kit under” optional it is possible to convert the unit into a downflow air conditioning unit (under).
Air conditioners for information technologyand communication - DISPLACEMENT
IDEN
TIFIC
ATIO
N
87RC GROUP SpA • General Catalogue• 155.EN.0504
CHAR
ACTE
RIST
ICSHousing with aluminium profile frame •
with galvanized steel sheet panels
externally coated with PVC film
Free-cooling proportional system •
3 way cooling valve with •
proportional action
Centrifugal fans •
Microprocessor control system •
Feeding voltage: •
Network + UPS at 230 Vac
Network + UPS at 48 Vdc
RS485 serial line •
Remote control board •
Clogged filters alarm •
Room humidity sensor •
Electric heater •
Fresh air kit for air suction •
and outdoor air discharge
Kit Under for unit conversion in •
downflow air conditioning unit
OPTI
ONAL
PEGASUS.CW.DL9 ÷ 55 kW
The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001certified.
SaveProprietary energy saving
system based on the fans
speed modulation according to
the real room load conditions,
the whole applied to
displacement technology.
TwinPowerDouble feeding voltage
system, network + UPS,
conceived to grant working
continuity even during
black-out periods.
EasyLinkAir kit for air suction and
outdoor air discharge
HIGH
LIGHT
S
88 RC GROUP SpA • General Catalogue • 155.EN.0504
RC GROUP liquid chillers: wide range of units in terms of models, compressors, refrigerants.
AIR COOLED LIQUID CHILLERSThe chillers are available in the versions with Scroll, Reciprocating and Screw type compressors.All models show a high energy efficiency and can be customized thanks to a wide range of optional extras including heat exchangers
for total or partial condensing heat reclaim.They are available with axial or centrifugal fans to allow the installation inside buildings with ducted air intake or exhaust systems.The latest generation and highly reliable microprocessor control system is equipped with RC PROACTIVE proprietary system and it isdesigned to be connected to the main Building Management and Remote Monitoring systems available on the market.
ELN RANGE (EXTREMELY LOW NOISE)For over 20 years RC Group has offered a standard catalogued range of units designed specifically to provide the "lowest noiseemission" equipment on the market.The design and continuous development of the ELN range has avoided using "bolt-on" acoustic kits, adding weight and reducing theserviceability of the equipment but instead has concentrated on removing the sound emissions at "source".By careful selection of matched components and innovative design of the condensing coil surface and airflow distribution, the ELN rangehas evolved into one of the quietest and thermally efficient Packaged Chillers in today's market place.This one solution grants : high efficiency, extremely low sound emissions and easy maintenance, no need to remove heavy noise reductionkits or acoustic barriers. The performance and durability of the RC Group solution lasts with time, unlike that of the materials of the"bolt-on" sound reduction kits that can decay over time.All RC Group chillers are available in the ELN range, including versions with axial or centrifugal fans.
PLAN
T TY
PEAir cooled liquid chillers
89RC GROUP SpA • General Catalogue • 155.EN.0504
EASY.A.STD “R” • R407C • 5 ÷ 41 kWLiquid chillers with scroll compressor.
EASY.A.STD “U” • R407C • 48 ÷ 186 kWLiquid chillers with scroll compressors.
EASY.A.STD “W” • R407C • 208 ÷ 460 kWLiquid chillers with scroll compressors.
CILLI.IDROCOMPL.A.STD.Z1 • R407C • 6 ÷ 17 kWIdrocompl liquid chillers with scroll compressor.
CILLI.IDROCOMPL.A.STD.Z2 • R407C • 20 ÷ 51 kWIdrocompl liquid chillers with scroll compressors.
UNICO.SCROLL.A.STD “G” • R407C • 20 ÷ 115 kWLiquid chillers with scroll compressors.
UNICO.SCROLL.A.ELN “G” • R407C • 19 ÷ 110 kWExtremely low noise liquid chillers with scroll compressors.
UNICO.RECIP.A.STD “G” • R407C • 137 ÷ 392 kWLiquid chillers with reciprocating compressors.
UNICO.RECIP.A.ELN “G” • R407C • 133 ÷ 271 kWExtremely low noise liquid chillers with reciprocating compressors.
UNICO.RECIP.A.STD “U” • R407C • 457 ÷ 990 kWLiquid chillers with reciprocating compressors.
UNICO.RECIP.A.ELN “U” • R407C • 355 ÷ 785 kWExtremely low noise liquid chillers with reciprocating compressors.
UNICO.RECIP.A.STD “M” • R407C • 500 ÷ 1950 kWLiquid chillers with reciprocating compressors.
MODULO.RECIP.A.STD • R407C • 200 ÷ 480 kWModular liquid chillers with reciprocating compressor.
UNICO.SCREW.A.STD “G” • R407C • 226 ÷ 379 kWLiquid chillers with screw compressors.
UNICO.SCREW.A.ELN “G” • R407C • 236 ÷ 314 kWExtremely low noise liquid chillers with screw compressors.
UNICO.SCREW.A.STD “U” • R407C • 444 ÷ 1137 kWLiquid chillers with screw compressors.
UNICO.SCREW.A.ELN “U” • R407C • 347 ÷ 850 kWExtremely low noise liquid chillers with screw compressors.
UNICO.SCREW.A.STD “M” • R407C • 564 ÷ 2331 kWLiquid chillers with screw compressors.
CILLI.IDROCOMPL.C.STD.Z1 • R407C • 6 ÷ 16 kWIdrocompl liquid chillers with scroll compressor.
CILLI.IDROCOMPL.C.STD.Z2 • R407C • 21 ÷ 51 kWIdrocompl liquid chillers with scroll compressors.
UNICO.SCROLL.C.STD “G” • R407C • 20 ÷ 112 kWLiquid chillers with scroll compressors.
UNICO.SCROLL.C.ELN “G” • R407C • 18 ÷ 110 kWExtremely low noise liquid chillers with scroll compressors.
UNICO.RECIP.C.STD “G” • R407C • 130 ÷ 265 kWLiquid chillers with reciprocating compressors.
UNICO.RECIP.C.ELN “G” • R407C • 130 ÷ 200 kWExtremely low noise liquid chillers with reciprocating compressors.
Air cooledliquid chillers
90 AXIAL FANS
92
94
96
98
100
102
104
106
108
110
112
114
116
118
120
122
124
126 CENTRIFUGAL FANS
128
130
132
134
136
INDE
X
90 RC GROUP SpA • General Catalogue • 155.EN.0504
EASY.A.STD “R” - MODELSizeCooling capacity (1) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgMean sound pressure level (2) dB(A)
EASY.A.STD “R” - MODELSizeCooling capacity (1) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgMean sound pressure level (2) dB(A)
M.5.Z1 M.6.Z1 M.8.Z1 M.9.Z1R1 R1 R1 R15,2 6,4 7,4 8,61 1 1 11 1 1 1
1048 1048 1048 1048460 460 460 460836 836 836 83680 80 82 8357 57 57 57
T.8.Z1 T.9.Z1 T.11.Z1 T.14.Z1 T.16.Z1 T.18.Z1 T.20.Z1 T.24.Z1 T.28.Z1 T.35.Z1 T.43.Z1R1 R1 R2 R2 R2 R2 R3 R3 R3 R4 R47,4 8,6 11 12,8 15,5 17,2 20 23,9 27,4 33,7 41,41 1 1 1 1 1 1 1 1 1 11 1 1 1 1 1 1 1 1 1 1
1048 1048 1305 1305 1305 1305 1305 1305 1305 1805 1805460 460 580 580 580 580 580 580 580 580 580836 836 900 900 900 900 1.285 1.285 1.285 1.285 1.28582 83 105 108 115 120 170 185 205 280 29557 57 57 57 60 60 59 59 62 62 62
(1) Data referred to chilled water temperature at 12/7°C; condenser air inlet at 35°C.(2) Mean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 230.1.50 for models “M” • 400.3.50+N for models “T”
Liquid chillers with axial fansTE
CHNI
CAL D
ATA
ServiceFastCompressors, electric board and electronic control system housed in a technical compartment
separated from the air flow to allow standard maintenance with the unit in operation.
EASY.A.STD “R”Packaged air cooled liquid chillers equipped with Scroll compressor and axial fans.
IDEN
TIFIC
ATIO
N
91RC GROUP SpA • General Catalogue • 155.EN.0504
CHAR
ACTE
RIST
ICSHousing in galvanized steel sheet •
externally coated with PVC film
Main components housed in a •
technical compartment separated
from the air flow
Plate evaporator •
Microprocessor control system •
Antifreeze system •
Water flow control •
Idronic group •
Modulating condensing control •
Remote control board •
RS485 serial line • OPTI
ONAL
EASY.A.STD “R”R407C • 5 ÷ 41 kW
The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.
DNA@RCTechnology of liquid chillers for
large installations transferred
to units dedicated to small
areas.
IdronicPackWater pump and tank in a
single package installed under
the chiller; a complete plant
without any increase in overall
dimensions.
Made2LastHousing designed to last in time
and in any weather condition.
HIGH
LIGHT
S
92 RC GROUP SpA • General Catalogue • 155.EN.0504
EASY.A.STD “U” - MODELSizeCooling capacity (1) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgMean sound pressure level (2) dB(A)
EASY.A.STD “U” - MODELSizeCooling capacity (1) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgMean sound pressure level (2) dB(A)
T.50.Z2 T.55.Z2 T.68.Z2 T.84.Z2U5 U5 U6 U6
47,8 55,9 67,5 83,82 2 2 21 1 1 1
2000 2000 2580 25801200 1200 1200 12001630 1630 1630 1630740 740 810 83561 61 62 62
T.100.Z2 T.125.Z2 T.150.Z3 T.188.Z3U7 U7 U8 U8
97,5 123 146,5 184,52 2 3 31 1 1 1
3020 3020 4120 41201200 1200 1800 18001950 1950 1950 19501060 1080 1620 166067 71 69 72
(1) Data referred to chilled water temperature at 12/7°C; condenser air inlet at 35°C.(2) Mean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 400.3.50+N
Liquid chillers with axial fansTE
CHNI
CAL D
ATA
AdaptiveRangeA wide range of models and optional designed for advanced air conditioning systems in
small and medium areas.
EASY.A.STD “U”Air cooled packaged liquid chillers equipped with Scroll compressors and axial fans.
IDEN
TIFIC
ATIO
N
93RC GROUP SpA • General Catalogue • 155.EN.0504
CHAR
ACTE
RIST
ICSHousing in galvanized steel sheet •
externally coated with PVC film
Main components housed in a •
technical compartment separated
from the air flow
Plate evaporator •
Microprocessor control system •
Antifreeze system •
Water flow control •
Modulating condensing control •
Step-step cooling capacity control •
Pump-Down stop •
Door lock main switch •
Idronic group •
Remote control board •
RS485 serial line •
Partial or total heat reclaim •
Mechanical flow switch •
Spring antivibration holders •
Outdoor air temperature sensor •
UDT, SQL or ASME VIII Div.1 approvals •
OPTI
ONAL
EASY.A.STD “U”R407C • 48 ÷ 185 kW
The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.
MP.COMThe new generation of RC
microprocessors with
AUTOADAPTIVE logic conceived to
self adapting in real time to the
effective working conditions
basing on punctual operating
parameters such as: water flow,
plant inertia, outdoor air
temperature and presence of
antifreeze solutions in the plant.
PerformancePlusUp to three SCROLL type compressors in parallel connection to grant
the maximum energy efficiency mainly in partial load operation, which
represent more than 70% of the yearlong working hours.
IdronicPackWater pump and tank in a single
package installed under the
chiller, a complete plant without
any increase in overall
dimensions.
HIGH
LIGHT
S
94 RC GROUP SpA • General Catalogue • 155.EN.0504
EASY.A.STD “W” - MODELSizeCooling capacity (1) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgMean sound pressure level (2) dB(A)
T.200.Z4 T.240.Z4 T.300.Z6 T.360.Z6 T.400.Z6 T..450.Z6W1 W1 W2 W2 W3 W3
208,7 247,7 312,3 370,8 410 4574 4 6 6 6 62 2 2 2 2 2
2606 2606 3756 3756 4840 48402320 2320 2320 2320 2320 23202490 2490 2490 2490 2490 24901820 2020 2670 2970 3050 315069 73 71 74 75 76
(1) Data referred to chilled water temperature at 12/7°C; condenser air inlet at 35°C.(2) Mean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 400.3.50+N
Liquid chillers with axial fansTE
CHNI
CAL D
ATA
EASY.A.STD “W”Air cooled packaged liquid chillers equipped with Scroll compressors and axial fans.
IDEN
TIFIC
ATIO
N
Made2LastHousing designed to last in time and in any weather condition: flexible capillary pipes to avoid problems deriving from
copper work hardening; antivibration holders under the compressors to reduce vibration transmission to the housing;
galvanized steel sheet parts; aluminium or stainless steel small parts.
95RC GROUP SpA • General Catalogue • 155.EN.0504
CHAR
ACTE
RIST
ICSHousing in epoxy painted •
galvanized steel sheet
Plate evaporator •
Microprocessor control system •
Water flow control •
Modulating condensing control •
Pump-Down stop •
Step-step cooling capacity control •
Door lock main switch •
Idronic group •
RS485 serial line •
Partial or total heat reclaim •
Mechanical flow switch •
Spring antivibration holders •
Outdoor air temperature sensor •
UDT, SQL or ASME VIII Div.1 approvals •
OPTI
ONAL
EASY.A.STD “W”R407C • 208 ÷ 450 kW
The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.
HIGH
LIGHT
S
QuickStartWhatever is needed for a correct operation is built-in.
Only electrical and water connections are needed at start-up for a
complete installation in full compliance with all the current norms.
MateIntegrated condensing control
system for a stepless speed
modulation of condensers
fans.
KeepCoolRC designs and dimensions its R407C chillers in such a
way as to ensure continuous operation also at extreme
outside temperatures, that, at present, are the norm also
in temperate zones.
96 RC GROUP SpA • General Catalogue • 155.EN.0504
Patent
CILLI.IDROCOMPL.A.STD.Z1 - MODELCooling capacity (1) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgMean sound pressure level (2) dB(A)
CILLI.IDROCOMPL.A.STD.Z1 - MODELCooling capacity (1) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgMean sound pressure level (2) dB(A)
M.7.Z1 M.8.Z1 M.9.Z16,2 7 8,41 1 11 1 1
1242 1242 1242447 447 447844 844 844135 137 14550 50 50
T.8.Z1 T.9.Z1 T.13.Z1 T.16.Z1 T.19.Z17 8,4 12,9 14,9 16,51 1 1 1 11 1 1 1 1
1242 1242 1342 1342 1342447 447 497 497 497844 844 969 969 969137 145 185 195 20550 50 54 54 54
(1) Data referred to chilled water temperature at 12/7°C; condenser air inlet at 35°C.(2) Mean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 230.1.50 for models “M” • 400.3.50+N for models “T”
Liquid chillers with axial fansTE
CHNI
CAL D
ATA
Idrocompl®Patented system including evaporator, water tank and expansion tank in a single component.
CILLI.IDROCOMPL.A.STD.Z1Air cooled packaged liquid chillers equipped with Scroll compressor, axial fan and Idrocompl system.
IDEN
TIFIC
ATIO
N
97RC GROUP SpA • General Catalogue • 155.EN.0504
CHAR
ACTE
RIST
ICSHousing in galvanized steel sheet •
externally coated with PVC film
IDROCOMPL system •
Microprocessor control system •
Antifreeze system •
On/off condensing control •
Circulating pump •
Modulating condensing control •
Remote control board •
RS485 serial line card • OPTI
ONAL
The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.
9
8
7
6
55
13
12
11
10
2 31 2 4
1. Water outlet2. Cooling circuits3. Magnesium anode4. Breather valve5. Temperature sensors6. Water pump (optional)7. Safety valve8. Water inlet9. Discharge tap10. Water tank11. Expansion tank12. Anticondensate insulation13. Gas/water heat exchanger
Idrocompl® System
NoFreezeAntifreeze system which totally
preserves from the risks
subsequent to water freezing
inside the evaporator.
CILLI.IDROCOMPL.A.STD.Z1R407C • 6 ÷ 17 kW
QuickStartWhatever is needed for a correct
operation is built-in.
Only electrical and water
connection are needed at start-up
for a complete installation in full
compliance with all the current
norms.
HIGH
LIGHT
S
98 RC GROUP SpA • General Catalogue • 155.EN.0504
CILLI.IDROCOMPL.A.STD.Z2 - MODELCooling capacity (1) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgMean sound pressure level (2) dB(A)
CILLI.IDROCOMPL.A.STD.Z2 - MODELCooling capacity (1) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgMean sound pressure level (2) dB(A)
T.24.Z2 T.28.Z2 T.34.Z221,4 24,2 28,7
2 2 21 1 1
1300 1300 1300895 895 895
1645 1645 1645375 385 42561 61 61
T.38.Z2 T.42.Z2 T.50.Z2 T.58.Z232,9 38 44,9 51,5
2 2 2 21 1 1 1
2000 2000 2000 2000895 895 895 895
1645 1645 1645 1645485 620 650 65562 64 64 64
(1) Data referred to chilled water temperature at 12/7°C; condenser air inlet at 35°C.(2) Mean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 400.3.50+N
Liquid chillers with axial fansTE
CHNI
CAL D
ATA
Made2LastHousing designed to last in time and in any weather condition: flexible capillary pipes to avoid
problems deriving from copper work hardening; antivibration holders under the
compressors to reduce vibration transmission to the housing; housing in anodized
aluminium; galvanized steel sheet parts; aluminium or stainless steel small parts.
IDEN
TIFIC
ATIO
N CILLI.IDROCOMPL.A.STD.Z2Air cooled packaged liquid chillers equipped with Scroll compressors, axial fans and Idrocompl system.
99RC GROUP SpA • General Catalogue • 155.EN.0504
CHAR
ACTE
RIST
ICSHousing with aluminium profile frame •
with galvanized steel sheet panels
externally coated with PVC film
IDROCOMPL system •
Microprocessor control system •
Antifreeze system •
On/off condensing control •
Circulating pump •
Modulating condensing control •
Remote control board •
RS485 serial line card •
Spring antivibration holders •
Main switch •
OPTI
ONAL
CILLI.IDROCOMPL.A.STD.Z2R407C • 20 ÷ 51 kW
The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.
CoolingDensityPlusOptimization of internal
layout to achieve the best
ratio between footprint and
cooling capacity.
ServiceFastCompressors, electric board and electronic control system housed in
a technical compartment separated from the air flow to allow
standard maintenance with the unit in operation.
ScrollThe state of the art technology
in the field of medium/small size
compressors.
HIGH
LIGHT
S
100 RC GROUP SpA • General Catalogue • 155.EN.0504
UNICO.SCROLL.A.STD “G” - MODELSizeCooling capacity (1) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgMean sound pressure level (2) dB(A)
UNICO.SCROLL.A.STD “G” - MODELSizeCooling capacity (1) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgMean sound pressure level (2) dB(A)
21.Z1 25.Z1 32.Z1 37.Z1 50.Z1 61.Z1G0 G0 G2 G2 G2 G4
20,3 23,2 32,5 36,7 49,3 56,51 1 1 1 1 11 1 1 1 1 1
1150 1150 2000 2000 2000 2600895 895 1040 1040 1040 1200
1640 1640 1690 1690 1690 1690330 330 480 540 590 75062 62 62 64 64 64
36.Z2 42.Z2 50.Z2 64.Z2 74.Z2 87.Z2 100.Z2 124.Z2G2 G2 G2 G4 G4 G6 G6 G6
34,6 40,3 45,5 60,4 69 87,5 97,9 114,92 2 2 2 2 2 2 22 2 2 2 2 2 2 2
2000 2000 2000 2600 2600 3600 3600 36001040 1040 1040 1200 1200 1290 1290 12901690 1690 1690 1690 1690 1690 1690 1690570 590 610 820 860 1180 1240 124064 64 64 64 65 65 65 66
(1) Data referred to chilled water temperature at 12/7°C; condenser air inlet at 35°C.(2) Mean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 400.3.50+N
Liquid chillers with axial fansTE
CHNI
CAL D
ATA
AdaptiveRangeA wide range of versions, models, to meet the requirements of a wide type of applications in
air conditioning systems for comfort, high-tech. and industrial cooling processes in any
climatic area.
UNICO.SCROLL.A.STD “G”Air cooled packaged liquid chillers equipped with Scroll compressors and axial fans.
Casing type: “G”.
IDEN
TIFIC
ATIO
N
101RC GROUP SpA • General Catalogue • 155.EN.0504
CHAR
ACTE
RIST
ICSHousing with aluminium profile frame •
with galvanized steel sheet panels
externally coated with PVC film
Main components housed in a •
technical compartment separated
from the air flow
Plate evaporator •
Microprocessor control system •
Step-step condensing control •
Pump-Down stop •
Differential pressure switch •
on water side
Door lock main switch •
LNO Kit for about a 6 dB(A) noise •
pressure level reduction
Modulating condensing control •
Pumping group with 1 or 2 pumps •
Water tank •
Partial or total heat reclaim •
Mechanical flow switch •
Spring antivibration holders •
RS232C-RS422-RS485 serial line •
Outdoor air temperature sensor •
UDT, SQL or ASME VIII Div.1 approvals •
OPTI
ONAL
UNICO.SCROLL.A.STD “G”R407C • 20 ÷ 115 kW
The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.
ScrollThe state of the art
technology in the field of
medium/small size
compressors.
PumpStationA complete built-in pumping
station (without size
increase), equipped with
instruments and safety
devices totally integrated with
the unit control system in
order to emphasize the RC
PROACTIVE system; possibility
to integrate PumpStation with
water tank without any
increase in footprint.
QuickStartWhatever is needed for a correct
operation is built-in.
Only electrical and water
connections are needed at start-
up for a complete installation in
full compliance with all the
current norms.
HIGH
LIGHT
S
Version available with R134a refrigerant chargesee page 274
102 RC GROUP SpA • General Catalogue • 155.EN.0504
ELN Range (Extremely low noise)For over 20 years RC Group has offered a complete range of units designed specifically to provide the "lowest noise
emission" equipment on the market.
The design and continuous development of the ELN range has avoided using "bolt-on" acoustic kits, adding weight and
reducing the serviceability of the equipment but instead has concentrated on removing the sound emissions at "source".
This one solution grants : high efficiency, extremely low sound emissions and easy maintenance, no need to remove
heavy noise reduction kits or acoustic barriers. The performance and durability of the RC Group solution lasts with
time, unlike that of the materials of the "bolt-on" sound reduction kits that can decay over time.
UNICO.SCROLL.A.ELN “G” - MODELSizeCooling capacity (1) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgMean sound pressure level (2) dB(A)
UNICO.SCROLL.A.ELN “G” - MODELSizeCooling capacity (1) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgMean sound pressure level (2) dB(A)
21.Z1 25.Z1 32.Z1 37.Z1 50.Z1 61.Z1G2 G2 G2 G4 G4 G4
19,1 22 29,2 34,7 45,8 55,41 1 1 1 1 11 1 1 1 1 1
2000 2000 2000 2600 2600 26001040 1040 1040 1200 1200 12001690 1690 1690 1690 1690 1690460 460 500 680 770 79050 53 51 53 54 55
36.Z2 42.Z2 50.Z2 64.Z2 74.Z2 87.Z2 100.Z2 124.Z2G4 G4 G4 G4 G6 G7 G7 G7
32,6 38,2 44,4 54,9 63,3 80,8 88,8 110,12 2 2 2 2 2 2 22 2 2 2 2 2 2 2
2600 2600 2600 2600 3600 3600 3600 36001200 1200 1200 1200 1290 1290 1290 12901690 1690 1690 1690 1690 2215 2215 2215720 750 750 820 1120 1230 1290 134053 51 55 55 53 56 56 57
(1) Data referred to chilled water temperature at 12/7°C; condenser air inlet at 35°C.(2) Mean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 400.3.50+N
Liquid chillers with axial fansTE
CHNI
CAL D
ATA
UNICO.SCROLL.A.ELN “G”Air cooled packaged liquid chillers in extremely low noise version equipped with Scroll
compressors and axial fans. Casing type: “G”.
IDEN
TIFIC
ATIO
N
103RC GROUP SpA • General Catalogue • 155.EN.0504
CHAR
ACTE
RIST
ICSHousing with aluminium profile frame •
with galvanized steel sheet panels
externally coated with PVC film
Main components housed in a •
technical compartment separated
from the air flow
Plate evaporator •
Microprocessor control system •
Modulating condensing control •
Pump-Down stop •
Differential pressure switch •
on water side
Door lock main switch •
Pumping group with 1 or 2 pumps •
Water tank •
Partial or total heat reclaim •
Mechanical flow switch •
Spring antivibration holders •
RS232C-RS422-RS485 serial line •
Outdoor air temperature sensor •
UDT, SQL or ASME VIII Div.1 approvals •
OPTI
ONAL
UNICO.SCROLL.A.ELN “G”R407C • 19 ÷ 110 kW
The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.
AntirumbleRigid base frame made of a
multiple layer structure with
high noise absorption
characteristics, to reduce the
noise emission from the bottom
of the unit.
ZytelThe special compressor
discharge piped made of
patented plastic material
avoid the vibrations
transmission from the
compressor to the
condensing coils reducing
the total noise emission
and avoiding the early
materials decay.
HIGH
LIGHT
S
Version available with R134a refrigerant chargesee page 274
104 RC GROUP SpA • General Catalogue • 155.EN.0504
UNICO.RECIP.A.STD “G” - MODELSizeCooling capacity (1) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgMean sound pressure level (2) dB(A)
UNICO.RECIP.A.STD “G” - MODELSizeCooling capacity (1) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgMean sound pressure level (2) dB(A)
142.F2 188.F2 220.F2 260.F2 300.F2G7 G7 G8 G8 G8
137,3 169,4 202 242,6 269,82 2 2 2 22 2 2 2 2
3600 3600 5170 5170 51701290 1290 1290 1290 12902115 2115 2155 2215 22151575 1730 2095 2435 245066 66 67 73 73
320.S2 350.F2 385.S2 440.S2G9 G9 G9 G9
303 325,5 356,1 392,62 2 2 22 2 2 2
5900 5900 5900 59001540 1540 1540 15402470 2470 2470 24704030 3330 4070 408074 74 74 74
(1) Data referred to chilled water temperature at 12/7°C; condenser air inlet at 35°C.(2) Mean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 400.3.50+N
Liquid chillers with axial fansTE
CHNI
CAL D
ATA
UNICO.RECIP.A.STD “G”Air cooled packaged liquid chillers equipped with reciprocating compressors and axial fans.
Casing type: “G”.
IDEN
TIFIC
ATIO
N
Made2LastHousing designed to last in time and in any weather condition: flexible capillary pipes to avoid
problems deriving from copper work hardening; antivibration holders under the
compressors to reduce vibration transmission to the housing; housing in anodized
aluminium; galvanized steel sheet parts; aluminium or stainless steel small parts.
105RC GROUP SpA • General Catalogue • 155.EN.0504
CHAR
ACTE
RIST
ICSHousing with aluminium profile frame •
with galvanized steel sheet panels
externally coated with PVC film
Main components housed in a •
technical compartment separated
from the air flow
Shell and tube evaporator •
Microprocessor control system •
Step-step condensing control •
Pump-Down stop •
Part-Winding compressors •
starting system (S)
Step-step cooling capacity control •
Door lock main switch •
LNO Kit for about a 6 dB(A) noise •
pressure level reduction
Modulating condensing control •
Pumping group with 1 or 2 pumps •
Water tank •
Partial or total heat reclaim •
Mechanical or electronic flow switch •
Spring antivibration holders •
RS232C-RS422-RS485 serial line •
Outdoor air temperature sensor •
UDT, SQL or ASME VIII Div.1 approvals •
OPTI
ONAL
UNICO.RECIP.A.STD “G”R407C • 137 ÷ 392 kW
The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.
ServiceFastCompressors, electric
board and electronic
control system housed in a
technical compartment
separated from the air
flow to allow standard
maintenance with the unit
in operation.
BufferTankWater tank to increase plant
inertia with an extreme reduction
of compressors start-up, harmful
for their reliability and
endurance.
HIGH
LIGHT
S
Version available with R134a refrigerant chargesee page 274
106 RC GROUP SpA • General Catalogue • 155.EN.0504
UNICO.RECIP.A.ELN “G” - MODELSizeCooling capacity (1) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgMean sound pressure level (2) dB(A)
UNICO.RECIP.A.ELN “G” - MODELSizeCooling capacity (1) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgMean sound pressure level (2) dB(A)
142.F2 188.F2 220.F2G8 G8 G8
133,5 163,6 187,82 2 22 2 2
5170 5170 51701290 1290 12902155 2155 21551915 2000 209054 54 57
260.F2 300.F2G9 G9
238,3 271,32 22 2
5900 59001540 15402470 24702670 267060 63
(1) Data referred to chilled water temperature at 12/7°C; condenser air inlet at 35°C.(2) Mean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 400.3.50+N
Liquid chillers with axial fansTE
CHNI
CAL D
ATA
UNICO.RECIP.A.ELN “G”Air cooled packaged liquid chillers in extremely low noise version equipped with reciprocating
compressors and axial fans. Casing type: “G”.
IDEN
TIFIC
ATIO
N
ELN Range (Extremely low noise)For over 20 years RC Group has offered a complete range of units designed specifically to provide the "lowest noise
emission" equipment on the market.
The design and continuous development of the ELN range has avoided using "bolt-on" acoustic kits, adding weight and
reducing the serviceability of the equipment but instead has concentrated on removing the sound emissions at "source".
This one solution grants : high efficiency, extremely low sound emissions and easy maintenance, no need to remove
heavy noise reduction kits or acoustic barriers. The performance and durability of the RC Group solution lasts with
time, unlike that of the materials of the "bolt-on" sound reduction kits that can decay over time.
107RC GROUP SpA • General Catalogue • 155.EN.0504
CHAR
ACTE
RIST
ICSHousing with aluminium profile frame •
with galvanized steel sheet panels
externally coated with PVC film
Main components housed in a •
technical compartment separated
from the air flow
Shell and tube evaporator •
Microprocessor control system •
Modulating condensing control •
Pump-Down stop •
Part-Winding compressors •
starting system (S)
Step-step cooling capacity control •
Door lock main switch •
Pumping group with 1 or 2 pumps •
Water tank •
Partial or total heat reclaim •
Part-Winding compressors •
starting system (F)
Mechanical or electronic flow switch •
Spring antivibration holders •
RS232C-RS422-RS485 serial line •
Outdoor air temperature sensor •
UDT, SQL or ASME VIII Div.1 approvals •
OPTI
ONAL
UNICO.RECIP.A.ELN “G”R407C • 133 ÷ 271 kW
The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.
CoolingDensityPlusOptimization of internal layout to achieve the best ratio between
footprint and cooling capacity.
RCProactiveMP99 microprocessor control
and monitoring system
technology owned by RC
PROACTIVE, designed to grant
continuous operation even in
emergency situations.
HIGH
LIGHT
S
Version available with R134a refrigerant chargesee page 274
108 RC GROUP SpA • General Catalogue • 155.EN.0504
UNICO.RECIP.A.STD “U” - MODELSizeCooling capacity (1) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgMean sound pressure level (2) dB(A)
UNICO.RECIP.A.STD “U” - MODELSizeCooling capacity (1) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgMean sound pressure level (2) dB(A)
495.S2 550.S2 600.S2 660.S2U10 U10 U11 U11
457,1 493,9 563,8 601,62 2 2 22 2 2 2
5500 5500 6490 64902130 2130 2130 21302430 2430 2430 24304450 4460 4960 514076 76 76 76
770.S2 880.S2 990.S2 1100.S2U12 U13 U14 U14
705,5 802,1 914,9 988,92 2 2 22 2 2 2
7480 8470 9460 94602130 2130 2130 21302430 2430 2430 24305870 6540 7140 715077 78 78 78
(1) Data referred to chilled water temperature at 12/7°C; condenser air inlet at 35°C.(2) Mean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 400.3.50+N
Liquid chillers with axial fansTE
CHNI
CAL D
ATA
UNICO.RECIP.A.STD “U”Air cooled packaged liquid chillers equipped with reciprocating compressors and axial fans.
Casing type: “U”.
IDEN
TIFIC
ATIO
N
FreezeProtectionEvaporator with built-in antifreeze heater and high thickness insulation, combined with
proprietary software for the automatic start up of the pumping group with direct scanning
from the digital antifreeze sensor.
109RC GROUP SpA • General Catalogue • 155.EN.0504
CHAR
ACTE
RIST
ICSHousing with aluminium profile frame •
with galvanized steel sheet panels
externally coated with PVC film
Main components housed in a •
technical compartment separated
from the air flow
Shell and tube evaporator •
Microprocessor control system •
Modulating condensing control •
Pump-Down stop •
Part-Winding compressors •
starting system
Step-step cooling capacity control •
Door lock main switch •
LNO Kit for about a 6 dB(A) noise •
pressure level reduction
Modulating condensing control •
Pumping group with 1 or 2 pumps •
Water tank •
Partial or total heat reclaim •
Mechanical or electronic flow switch •
Spring antivibration holders •
RS232C-RS422-RS485 serial line •
Outdoor air temperature sensor •
UDT, SQL or ASME VIII Div.1 approvals •
OPTI
ONAL
UNICO.RECIP.A.STD “U”R407C • 457 ÷ 990 kW
The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.
ServiceFastCompressors, electric
board and electronic
control system housed in
a technical compartment
separated from the air
flow to allow standard
maintenance with the unit
in operation.
MyNoiseSolutions range (STD-LNO) conceived to allow the selection directly
from the catalogue of the most suitable product for the specific
legislative or environmental demands regarding the noise emission
control.
HIGH
LIGHT
S
Version available with R134a refrigerant chargesee page 274
110 RC GROUP SpA • General Catalogue • 155.EN.0504
UNICO.RECIP.A.ELN “U” - MODELSizeCooling capacity (1) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgMean sound pressure level (2) dB(A)
UNICO.RECIP.A.ELN “U” - MODELSizeCooling capacity (1) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgMean sound pressure level (2) dB(A)
320.S2 350.F2 385.S2 440.S2 495.S2U10 U10 U10 U10 U11
307,9 333,7 356,3 392,9 456,22 2 2 2 22 2 2 2 2
5500 5500 5500 5500 64902130 2130 2130 2130 21302430 2430 2430 2430 24304300 3600 4340 4350 495063 63 63 63 63
550.S2 600.S2 660.S2 770.S2 880.S2U11 U12 U12 U13 U14
492,7 558,4 595 693,9 786,12 2 2 2 22 2 2 2 2
6490 7480 7480 8470 94602130 2130 2130 2130 21302430 2430 2430 2430 24304960 5670 5670 6370 702063 63 63 64 64
(1) Data referred to chilled water temperature at 12/7°C; condenser air inlet at 35°C.(2) Mean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 400.3.50+N
Liquid chillers with axial fansTE
CHNI
CAL D
ATA
UNICO.RECIP.A.ELN “U”Air cooled packaged liquid chillers in extremely low noise version equipped with reciprocating
compressors and axial fans. Casing type: “U”.
IDEN
TIFIC
ATIO
N
ELN Range (Extremely low noise)For over 20 years RC Group has offered a complete range of units designed specifically to provide the "lowest noise
emission" equipment on the market.
The design and continuous development of the ELN range has avoided using "bolt-on" acoustic kits, adding weight and
reducing the serviceability of the equipment but instead has concentrated on removing the sound emissions at "source".
This one solution grants : high efficiency, extremely low sound emissions and easy maintenance, no need to remove
heavy noise reduction kits or acoustic barriers. The performance and durability of the RC Group solution lasts with
time, unlike that of the materials of the "bolt-on" sound reduction kits that can decay over time.
111RC GROUP SpA • General Catalogue • 155.EN.0504
CHAR
ACTE
RIST
ICSHousing with aluminium profile frame •
with galvanized steel sheet panels
externally coated with PVC film
Main components housed in a •
technical compartment separated
from the air flow
Shell and tube evaporator •
Microprocessor control system •
Modulating condensing control •
Pump-Down stop •
Part-Winding compressors •
starting system
Step-step cooling capacity control •
Door lock main switch •
Pumping group with 1 or 2 pumps •
Water tank •
Partial or total heat reclaim •
Mechanical or electronic flow switch •
Spring antivibration holders •
RS232C-RS422-RS485 serial line •
UDT, SQL or ASME VIII Div.1 approvals •
OPTI
ONAL
UNICO.RECIP.A.ELN “U”R407C • 355 ÷ 785 kW
The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.
Easy@ServeAll components are
accessible through handy
hinged panels equipped
with antiwind lock,
without removal of heavy
noise deading boxes.
AntirumbleRigid base frame made of a multiple
layer structure with high noise
absorption characteristics, to reduce
the noise emission from the bottom of
the unit.
It is an essential device in all those
installations where the units are
installed ”raised” from the floor
through distribution bars and/or
antivibration holders.
HIGH
LIGHT
S
Version available with R134a refrigerant chargesee page 274
112 RC GROUP SpA • General Catalogue • 155.EN.0504
UNICO.RECIP.A.STD “M” - MODELSizeCooling capacity (1) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgMean sound pressure level (2) dB(A)
UNICO.RECIP.A.STD “M” - MODELSizeCooling capacity (1) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgMean sound pressure level (2) dB(A)
550.S2 600.S2 660.S2 770.S2 880.S2 990.S2 1100.S2 1210.S3 1320.S3M16 M16 M16 M17 M17 M18 M18 M19 M20506,4 558,2 600,4 703,8 782,2 893,4 972,4 1092,7 1197,4
2 2 2 2 2 2 2 3 32 2 2 2 2 2 2 3 3
5000 5000 5000 6070 6070 7140 7140 8490 95602350 2350 2350 2350 2350 2350 2350 2350 23502510 2510 2510 2510 2510 2510 2510 2510 25105110 5110 5110 5900 6060 6620 6620 8350 916084 84 84 84 84 84 85 85 85
1420.S3 1530.S3 1640.S3 1750.S4 1860.S4 1970.S4 2080.S4 2190.S4M20 M21 M21 M17+M17 M18+M17 M18+M17 M18+M18 M18+M18
1286,5 1393,5 1463,6 1564,4 1672,8 1733,6 1875,5 1944,93 3 3 4 4 4 4 43 3 3 4 4 4 4 4
9560 10630 10630 12190 13260 13260 14330 143302350 2350 2350 2350 2350 2350 2350 23502510 2510 2510 2510 2510 2510 2510 25109420 9600 9600 11920 12580 12580 13240 1324085 85 85 86 86 86 86 86
(1) Data referred to chilled water temperature at 12/7°C; condenser air inlet at 35°C.(2) Mean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 400.3.50+N
Liquid chillers with axial fansTE
CHNI
CAL D
ATA
UNICO.RECIP.A.STD “M”Air cooled packaged liquid chillers equipped with reciprocating compressors and axial fans.
Casing type: “M”. M+M model casing is separated into two different sections to allow easier transport
and handling.
IDEN
TIFIC
ATIO
N
MyNoiseSolutions range (STD-LNO) conceived to allow the selection directly from the catalogue of the
most suitable product for the specific legislative or environmental demands regarding the
noise emission control.
113RC GROUP SpA • General Catalogue • 155.EN.0504
CHAR
ACTE
RIST
ICSHousing made of epoxy painted •
galvanized steel sheet
Shell and tube evaporator •
Microprocessor control system •
Step-step condensing control •
Pump-Down stop •
Part-Winding compressors •
starting system
Step-step cooling capacity control •
Door lock main switch •
LNO Kit for about a 6 dB(A) noise •
pressure level reduction
Modulating condensing control •
Partial or total heat reclaim •
Mechanical or electronic flow switch •
Spring antivibration holders •
RS232C-RS422-RS485 serial line •
Outdoor air temperature sensor •
UDT, SQL or ASME VIII Div.1 approvals •
OPTI
ONAL
UNICO.RECIP.A.STD “M”R407C • 500 ÷ 1950 kW
The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.
ServiceFastCompressors, electric board
and electronic control system
housed in a technical
compartment separated from
the air flow to allow standard
maintenance with the unit in
operation.
AdaptiveRangeA wide range of models and optional designed to meet
the requirements of a wide type of applications in large
air conditioning installations and industrial cooling
systems.
HIGH
LIGHT
S
Version available with R134a refrigerant chargesee page 274
114 RC GROUP SpA • General Catalogue • 155.EN.0504
CoolingDensityPlus480kW in 6,5 m2 (DF = 74 kW/m2), the chiller with the highest Cooling Density (kW per m2 of
space in plan) currently available in the market.
MODULO.RECIP.A.STD - MODELCooling capacity (1) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgMean sound pressure level (2) dB(A)
MODULO.RECIP.A.STD - MODELCooling capacity (1) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgMean sound pressure level (2) dB(A)
220.S1 330.S1208 297,11 11 1
2830 28302300 23002395 23952700 296077 78
440.S1 550.S1396,5 478,4
1 11 1
2830 28302300 23002395 23953130 330080 80
(1) Data referred to chilled water temperature at 12/7°C; condenser air inlet at 35°C.(2) Mean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 400.3.50+N
Liquid chillers with axial fansTE
CHNI
CAL D
ATA
MODULO.RECIP.A.STDModular air cooled packaged liquid chillers equipped with reciprocating compressor and axial fans.
IDEN
TIFIC
ATIO
N
115RC GROUP SpA • General Catalogue • 155.EN.0504
CHAR
ACTE
RIST
ICSHousing made of epoxy painted •
galvanized steel sheet
Shell and tube evaporator •
Microprocessor control system •
Step-step condensing control •
Pump-Down stop •
Part-Winding compressors •
starting system
Step-step cooling capacity control •
Door lock main switch •
LNO Kit for about a 6 dB(A) noise •
pressure level reduction
Modulating condensing control •
Pumping group with 1 or 2 pumps •
Mechanical or electronic flow switch •
Spring antivibration holders •
RS232C-RS422-RS485 serial line •
Outdoor air temperature sensor •
UDT, SQL or ASME VIII Div.1 approvals •
OPTI
ONAL
MODULO.RECIP.A.STDR407C • 200 ÷ 480 kW
The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.
PumpStationA complete built-in pumping
station (without size increase),
equipped with instruments and
safety devices totally
integrated with the unit control
system in order to emphasize
the RC PROACTIVE system.
TR88Supervision and remote control
system; up to 8 MODULO can be
supervised in installations with
constant and variable flow
rate.
SideBySideMODULO is designed to be installed side by side to obtain
very high cooling capacities in reduced areas (for instance:
2 MW in only 26 m2 footprint!)
HIGH
LIGHT
S
Version available with R134a refrigerant chargesee page 274
116 RC GROUP SpA • General Catalogue • 155.EN.0504
UNICO.SCREW.A.STD “G” - MODELSizeCooling capacity (1) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgMean sound pressure level (2) dB(A)
UNICO.SCREW.A.STD “G” - MODELSizeCooling capacity (1) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgMean sound pressure level (2) dB(A)
230.V1 280.V1 330.V1 370.V1G8 G9 G9 G9
226,7 274,1 337,1 372,31 1 1 11 1 1 1
5170 5900 5900 59001290 1540 1540 15402155 2470 2470 24702265 3155 3300 332071 72 72 72
200.V2 240.V2 280.V2 320.V2 380.V2G8 G8 G9 G9 G9
205 241,3 242,4 331,6 3792 2 2 2 22 2 2 2 2
5170 5170 5900 5900 59001290 1290 1540 1540 15402155 2155 2470 2470 24702300 2310 3145 3590 362572 72 73 73 73
(1) Data referred to chilled water temperature at 12/7°C; condenser air inlet at 35°C.(2) Mean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 400.3.50+N
Liquid chillers with axial fansTE
CHNI
CAL D
ATA
UNICO.SCREW.A.STD “G”Air cooled packaged liquid chillers equipped with screw compressors and axial fans.
Casing type: “G”.
IDEN
TIFIC
ATIO
N
ScrewHelical twin screw compressors with high efficiency, possibility of proportional or multistep
setting, designed for air cooled chillers (high condensing temperatures).
117RC GROUP SpA • General Catalogue • 155.EN.0504
CHAR
ACTE
RIST
ICSHousing with aluminium profile frame •
with galvanized steel sheet panels
externally coated with PVC film
Main components housed in a •
technical compartment separated
from the air flow
Shell and tube evaporator •
Microprocessor control system •
Step-step condensing control •
Pump-Down stop •
Oil cooling system •
Star/delta compressors starting system •
Door lock main switch •
LNO Kit for about a 6 dB(A) noise •
pressure level reduction
Modulating condensing control •
Pumping group with 1 or 2 pumps •
Water tank •
Partial heat reclaim •
Mechanical or electronic flow switch •
Spring antivibration holders •
RS232C-RS422-RS485 serial line •
Outdoor air temperature sensor •
UDT, SQL or ASME VIII Div.1 approvals •
OPTI
ONAL
UNICO.SCREW.A.STD “G”R407C • 226 ÷ 379 kW
The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.
Easy@ServAll components are
accessible from the front
of the unit allowing the
check and set of all
systems with the unit in
working mode.
RCProactiveMP99 microprocessor control and
monitoring system technology owned
by RC PROACTIVE, designed to grant
continuity of work even in
emergency situations.
HIGH
LIGHT
S
Version available with R134a refrigerant chargesee page 274
118 RC GROUP SpA • General Catalogue • 155.EN.0504
UNICO.SCREW.A.ELN “G” - MODELSizeCooling capacity (1) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgMean sound pressure level (2) dB(A)
UNICO.SCREW.A.ELN “G” - MODELSizeCooling capacity (1) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgMean sound pressure level (2) dB(A)
230.V1 280.V1G9 G9236 280,71 11 1
5900 59001540 15402470 24703075 315560 60
200.V2 240.V2 280.V2 320.V2G8 G9 G9 G9
191,7 245,3 278,5 314,32 2 2 22 2 2 2
5170 5900 5900 59001290 1540 1540 15402155 2470 2470 24702300 3120 3145 359056 61 61 61
(1) Data referred to chilled water temperature at 12/7°C; condenser air inlet at 35°C.(2) Mean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 400.3.50+N
Liquid chillers with axial fansTE
CHNI
CAL D
ATA
IDEN
TIFIC
ATIO
N UNICO.SCREW.A.ELN “G”Air cooled packaged liquid chillers in extremely low noise version equipped with screw compressors
and axial fans. Casing type: “G”.
ELN Range (Extremely low noise)Over 20 years of experience in sound reduction techniques together with SCREW technology enable RC Group to grant
sound emission levels never achieved in chillers with such reduced dimensions.
The result as for all ELN range chillers is achieved by a specific design philosophy concentrated on removing the sound
emissions at "source", without using "bolt-on" acoustic kits that can result in detrimental product efficiency, maintenance
and durability.
Screw ELN range allows design compliance to meet specific legislative or environmental acoustic control measures.
119RC GROUP SpA • General Catalogue • 155.EN.0504
CHAR
ACTE
RIST
ICSHousing with aluminium profile frame •
with galvanized steel sheet panels
externally coated with PVC film
Main components housed in a •
technical compartment separated
from the air flow
Shell and tube evaporator •
Microprocessor control system •
Modulating condensing control •
Pump-Down stop •
Step-step cooling capacity control •
Oil cooling system •
Star/delta compressors starting system •
Door lock main switch •
Pumping group with 1 or 2 pumps •
Water tank •
Partial heat reclaim •
Mechanical or electronic flow switch •
Spring antivibration holders •
RS232C-RS422-RS485 serial line •
Outdoor air temperature sensor •
UDT, SQL or ASME VIII Div.1 approvals •
OPTI
ONAL
UNICO.SCREW.A.ELN “G”R407C • 236 ÷ 314 kW
The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.
HIGH
LIGHT
S
AntirumbleRigid base frame made of a multiple
layer structure with high noise
absorption characteristics, to reduce
the noise emission from the bottom of
the unit.
It is an essential device in all those
installations where the units are
installed ”raised” from the floor
through distribution bars and/or
antivibration holders.
MateIntegrated condensing control
system for a stepless speed
modulation of condensers fans.
Version available with R134a refrigerant chargesee page 274
120 RC GROUP SpA • General Catalogue • 155.EN.0504
UNICO.SCREW.A.STD “U” - MODELSizeCooling capacity (1) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgMean sound pressure level (2) dB(A)
UNICO.SCREW.A.STD “U” - MODELSizeCooling capacity (1) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgMean sound pressure level (2) dB(A)
420.V1 470.V1 500.V1 550.V1U10 U10 U10 U11
444,1 477,1 498,5 587,71 1 1 11 1 1 1
5500 5500 5500 64902130 2130 2130 21302430 2430 2430 24303800 4000 4100 450075 75 75 75
460.V2 560.V2 660.V2 740.V2 840.V2 940.V2 1000.V2 1100.V2U10 U11 U11 U12 U13 U13 U14 U14
468,6 567,6 655,7 733,3 855,7 941,2 1003,7 1137,82 2 2 2 2 2 2 22 2 2 2 2 2 2 2
5500 6490 6490 7480 8470 8470 9460 94602130 2130 2130 2130 2130 2130 2130 21302430 2430 2430 2430 2430 2430 2430 24304200 4850 4900 5600 6500 6700 7350 737076 76 76 77 78 78 79 79
(1) Data referred to chilled water temperature at 12/7°C; condenser air inlet at 35°C.(2) Mean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 400.3.50+N
Liquid chillers with axial fansTE
CHNI
CAL D
ATA
UNICO.SCREW.A.STD “U”Air cooled packaged liquid chillers equipped with screw compressors and axial fans.
Casing type: “U”.
Made2LastHousing designed to last in time and in any weather condition: flexible capillary pipes to avoid
problems deriving from copper work hardening; antivibration holders under the
compressors to reduce vibration transmission to the housing; housing in anodized
aluminium; galvanized steel sheet parts; aluminium or stainless steel small parts.
IDEN
TIFIC
ATIO
N
121RC GROUP SpA • General Catalogue • 155.EN.0504
CHAR
ACTE
RIST
ICSHousing with aluminium profile frame •
with galvanized steel sheet panels
externally coated with PVC film
Main components housed in a •
technical compartment separated
from the air flow
Shell and tube evaporator •
Microprocessor control system •
Step-step condensing control •
Pump-Down stop •
Step-step cooling capacity control •
Oil cooling system •
Star/delta compressors starting system •
Door lock main switch •
LNO Kit for about a 6 dB(A) noise •
pressure level reduction
Modulating condensing control •
Pumping group with 1 or 2 pumps •
Water tank •
Partial or total heat reclaim •
Mechanical or electronic flow switch •
Spring antivibration holders •
RS232C-RS422-RS485 serial line •
Outdoor air temperature sensor •
UDT, SQL or ASME VIII Div.1 approvals •
OPTI
ONAL
UNICO.SCREW.A.STD “U”R407C • 444 ÷ 1137 kW
The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.
ScrewHelical twin screw compressors with high efficiency, possibility of
proportional or multistep setting, designed for air cooled chillers
(high condensing temperatures).
HIGH
LIGHT
S
MyNoiseSolutions range (STD-LNO) conceived to
allow the selection directly from the
catalogue of the most suitable product for
the specific legislative or environmental
demands regarding the noise emission
control.
Version available with R134a refrigerant chargesee page 274
122 RC GROUP SpA • General Catalogue • 155.EN.0504
UNICO.SCREW.A.ELN “U” - MODELSizeCooling capacity (1) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgMean sound pressure level (2) dB(A)
UNICO.SCREW.A.ELN “U” - MODELSizeCooling capacity (1) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgMean sound pressure level (2) dB(A)
330.V1 370.V1 420.V1 470.V1 500.V1 550.V1U10 U10 U10 U11 U11 U12
347,1 376,9 426,8 480,1 501,9 585,11 1 1 1 1 11 1 1 1 1 1
5500 5500 5500 6490 6490 74802130 2130 2130 2130 2130 21302430 2430 2430 2430 2430 24303560 3610 3900 4400 4480 500062 62 62 62 62 62
380.V2 460.V2 560.V2 660.V2 740.V2 840.V2U10 U11 U12 U12 U13 U14384 472 564,7 644,3 732,7 850,12 2 2 2 2 22 2 2 2 2 2
5500 6490 7480 7480 8470 94602130 2130 2130 2130 2130 21302430 2430 2430 2430 2430 24303900 4600 5200 5270 6150 695063 63 63 64 64 64
(1) Data referred to chilled water temperature at 12/7°C; condenser air inlet at 35°C.(2) Mean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 400.3.50+N
Liquid chillers with axial fansTE
CHNI
CAL D
ATA
IDEN
TIFIC
ATIO
N UNICO.SCREW.A.ELN “U”Air cooled packaged liquid chillers in extremely low noise version equipped with screw compressors
and axial fans. Casing type: “U”.
ELN Range (Extremely low noise)Over 20 years of experience in sound reduction techniques together with SCREW technology enable RC Group to grant
sound emission levels never achieved in chillers with such reduced dimensions.
The result as for all ELN range chillers is achieved by a specific design philosophy concentrated on removing the sound
emissions at "source", without using "bolt-on" acoustic kits that can result in detrimental product efficiency, maintenance
and durability.
Screw ELN range allows design compliance to meet specific legislative or environmental acoustic control measures.
123RC GROUP SpA • General Catalogue • 155.EN.0504
CHAR
ACTE
RIST
ICSHousing with aluminium profile frame •
with galvanized steel sheet panels
externally coated with PVC film
Main components housed in a •
technical compartment separated
from the air flow
Shell and tube evaporator •
Microprocessor control system •
Modulating condensing control •
Pump-Down stop •
Step-step cooling capacity control •
Oil cooling system •
Star/delta compressors starting system •
Door lock main switch •
Pumping group with 1 or 2 pumps •
Water tank •
Partial or total heat reclaim •
Mechanical or electronic flow switch •
Spring antivibration holders •
RS232C-RS422-RS485 serial line •
Outdoor air temperature sensor •
UDT, SQL or ASME VIII Div.1 approvals •
OPTI
ONAL
UNICO.SCREW.A.ELN “U”R407C • 347 ÷ 850 kW
The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.
Easy@ServAll components are accessible through handy hinged panels equipped
with antiwind lock, without removal of heavy noise deading boxes.
HIGH
LIGHT
S
PumpStationA complete built-in pumping station
(without size increase), equipped
with instruments and safety
devices totally integrated with the
unit control system in order to
emphasize the RC PROACTIVE
system; possibility to integrate
PumpStation with water tank
without any increase in footprint.
Version available with R134a refrigerant chargesee page 274
124 RC GROUP SpA • General Catalogue • 155.EN.0504
UNICO.SCREW.A.STD “M” - MODELSizeCooling capacity (1) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgMean sound pressure level (2) dB(A)
UNICO.SCREW.A.STD “M” - MODELSizeCooling capacity (1) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgMean sound pressure level (2) dB(A)
560.V2 650.V2 740.V2 840.V2 940.V2 1000.V2 1100.V2M16 M16 M17 M18 M18 M19 M19564,5 649 738,9 867,4 951,4 1027 1165,5
2 2 2 2 2 2 22 2 2 2 2 2 2
5000 5000 6070 7140 7140 8210 82102350 2350 2350 2350 2350 2350 23502510 2510 2510 2510 2510 2510 25104650 4700 5500 6500 6750 7450 750079 79 79 80 80 81 81
1260.V3 1410.V3 1500.V3 1650.V3 1780.V4 1880.V4 2000.V4 2200.V4M20 M21 M21 M22 M17+M18 M18+M18 M19+M19 M19+M19
1300,2 1405,2 1517,1 1715,8 1781 1868,2 2053,9 2331,13 3 3 3 4 4 4 43 3 3 3 4 4 4 4
9560 10630 10630 11700 13260 14330 16470 164702350 2350 2350 2350 2350 2350 2350 23502510 2510 2510 2510 2510 2510 2510 25108950 9000 9770 10400 12670 13500 14500 1475084 84 84 84 85 85 85 85
(1) Data referred to chilled water temperature at 12/7°C; condenser air inlet at 35°C.(2) Mean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 400.3.50+N
Liquid chillers with axial fans
UNICO.SCREW.A.STD “M”Air cooled packaged liquid chillers equipped with screw compressors and axial fans.
Casing type: “M”. M+M model casing is separated into two different sections to allow
easier transport and handling.
FreezeProtectionEvaporator with built-in antifreeze heater and high thickness insulation, combined with
proprietary software for the automatic start up of the pumping group with direct scanning
from the digital antifreeze sensor.
IDEN
TIFIC
ATIO
NTE
CHNI
CAL D
ATA
125RC GROUP SpA • General Catalogue • 155.EN.0504
CHAR
ACTE
RIST
ICSHousing made of epoxy painted •
galvanized steel sheet
Shell and tube evaporator •
Microprocessor control system •
Step-step condensing control •
Pump-Down stop •
Star/delta compressors starting system •
Step-step cooling capacity control •
Oil cooling system •
Door lock main switch •
LNO Kit for about a 6 dB(A) noise •
pressure level reduction
Modulating condensing control •
Partial or total heat reclaim •
Mechanical or electronic flow switch •
Spring antivibration holders •
RS232C-RS422-RS485 serial line •
Outdoor air temperature sensor •
UDT, SQL or ASME VIII Div.1 approvals •
OPTI
ONAL
UNICO.SCREW.A.STD “M”R407C • 560 ÷ 2331 kW
The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.
CoolingDensityPlusOptimization of internal layout to achieve the best ratio between
footprint and cooling capacity.
HIGH
LIGHT
S
ScrewHelical twin screw compressors
with high efficiency, possibility of
proportional or multistep setting,
designed for air cooled chillers
(high condensing temperatures).
Version available with R134a refrigerant chargesee page 274
126 RC GROUP SpA • General Catalogue • 155.EN.0504
CILLI.IDROCOMPL.C.STD.Z1 - MODELCooling capacity (1) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgMean sound pressure level (2) dB(A)
CILLI.IDROCOMPL.C.STD.Z1 - MODELCooling capacity (1) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgMean sound pressure level (2) dB(A)
M.7.Z1 M.8.Z1 M.9.Z16,1 6,9 8,21 1 11 1 1
1242 1242 1242447 447 447844 844 844140 140 15058 58 58
T.8.Z1 T.9.Z1 T.13.Z1 T.16.Z1 T.19.Z16,9 8,2 12,6 14,4 15,91 1 1 1 11 1 1 1 1
1242 1242 1342 1342 1342447 447 497 497 497844 844 969 969 969142 150 185 200 24058 58 64 64 64
(1) Data referred to chilled water temperature at 12/7°C; condenser air inlet at 35°C.(2) Mean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 230.1.50 for models “M” • 400.3.50+N for models “T”
Liquid chillers with centrifugal fansTE
CHNI
CAL D
ATA
IDEN
TIFIC
ATIO
N CILLI.IDROCOMPL.C.STD.Z1Air cooled packaged liquid chillers equipped with Scroll compressor, centrifugal fan and Idrocompl
system.
ServiceFastCompressor, electric board and electronic control system housed in a technical compartment separated
from the air flow to allow standard maintenance with the unit in operation.
127RC GROUP SpA • General Catalogue • 155.EN.0504
CHAR
ACTE
RIST
ICSHousing in galvanized steel sheet •
externally coated with PVC film
IDROCOMPL system •
Microprocessor control system •
Antifreeze system •
On/off condensing control •
Circulating pump •
Modulating condensing control •
Remote control board •
RS485 serial line •
Spring antivibration holders •
Main switch •
OPTI
ONAL
CILLI.IDROCOMPL.C.STD.Z1R407C • 6 ÷ 16 kW
The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.
CentriCentrifugal fan version for indoor and/or ducted
installations.
HIGH
LIGHT
S
ScrollThe state of the art technology in
the field of medium/small size
compressors.
Pump&PressureBuilt-in circulating pump with
water pressure control,
controlled by the central
microprocessor system.
128 RC GROUP SpA • General Catalogue • 155.EN.0504
Patent
CILLI.IDROCOMPL.C.STD.Z2 - MODELCooling capacity (1) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgMean sound pressure level (2) dB(A)
CILLI.IDROCOMPL.C.STD.Z2 - MODELCooling capacity (1) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgMean sound pressure level (2) dB(A)
T.24.Z2 T.28.Z2 T.34.Z221,4 24,2 28,7
2 2 21 1 1
1300 1300 1300895 895 8951645 1645 1645375 385 42566 66 66
T.38.Z2 T.42.Z2 T.50.Z2 T.58.Z232,9 38 44,9 51,5
2 2 2 21 1 1 1
2000 2000 2000 2000895 895 895 8951645 1645 1645 1645485 620 650 65568 69 69 69
(1) Data referred to chilled water temperature at 12/7°C; condenser air inlet at 35°C.(2) Mean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 400.3.50+N
Liquid chillers with centrifugal fansTE
CHNI
CAL D
ATA
IDEN
TIFIC
ATIO
N CILLI.IDROCOMPL.C.STD.Z2Air cooled packaged liquid chillers equipped with Scroll compressors, centrifugal fan and Idrocompl
system.
IdrocomplPatented system including evaporator, water tank and expansion tank in a single component.
129RC GROUP SpA • General Catalogue • 155.EN.0504
CHAR
ACTE
RIST
ICSHousing with aluminium profile frame •
with galvanized steel sheet panels
externally coated with PVC film
IDROCOMPL system •
Microprocessor control system •
Antifreeze system •
On/off condensing control •
Circulating pump •
Modulating condensing control •
Remote control board •
RS485 serial line •
Spring antivibration holders •
Main switch •
OPTI
ONAL
CILLI.IDROCOMPL.C.STD.Z2R407C • 21÷ 51 kW
The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.
NoFreezeAntifreeze system which totally
preserves from the risks
subsequent to water freezing
inside the evaporator.
HIGH
LIGHT
S
9
8
7
6
55
13
12
11
10
2 31 2 41. Water outlet2. Cooling circuits3. Magnesium anode4. Breather valve5. Temperature sensors6. Water pump (optional)7. Safety valve8. Water inlet9. Discharge tap10. Water tank11. Expansion tank12. Anticondensate insulation13. Gas/water heat exchanger
Idrocompl® system
PerformancePlusSCROLL type compressors in parallel connection to grant the
maximum energy efficiency mainly in partial load operation, which
represent more than 70% of the yearlong working hours.
130 RC GROUP SpA • General Catalogue • 155.EN.0504
UNICO.SCROLL.C.STD “G” - MODELSizeCooling capacity (1) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgMean sound pressure level (2) dB(A)
UNICO.SCROLL.C.STD “G” - MODELSizeCooling capacity (1) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgMean sound pressure level (2) dB(A)
21.Z1 25.Z1 32.Z1 37.Z1 50.Z1 61.Z1G1 G1 G1 G3 G3 G3
19,2 21,8 28,7 35,2 46,9 56,81 1 1 1 1 11 1 1 1 1 1
1150 1150 1150 2000 2000 2000895 895 895 1040 1040 1040
1960 1960 1960 2010 2010 2010390 390 435 670 740 76059 59 66 60 68 68
36.Z2 42.Z2 50.Z2 64.Z2 74.Z2 87.Z2 100.Z2 124.Z2G3 G3 G3 G3 G5 G7 G7 G7
32,5 38 43,1 56,3 69 83,8 92,8 1122 2 2 2 2 2 2 22 2 2 2 2 2 2 2
2000 2000 2000 2000 2600 3600 3600 36001040 1040 1040 1040 1200 1290 1290 12902010 2010 2010 2010 2240 2010 2010 2010690 710 720 790 1060 1450 1510 154059 60 64 68 70 69 69 69
(1) Data referred to chilled water temperature at 12/7°C; condenser air inlet at 35°C.(2) Mean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 400.3.50+N
Liquid chillers with centrifugal fansTE
CHNI
CAL D
ATA
UNICO.SCROLL.C.STD “G”Air cooled packaged liquid chillers equipped with Scroll compressors and centrifugal fans.
Casing type: “G”.
IDEN
TIFIC
ATIO
N
ScrollUNICO.SCROLL range is equipped with latest generation of Scroll compressors to grant the
highest efficiency and reduced noise emission.
131RC GROUP SpA • General Catalogue • 155.EN.0504
CHAR
ACTE
RIST
ICSHousing with aluminium profile frame •
with galvanized steel sheet panels
externally coated with PVC film
Main components housed in a •
technical compartment separated
from the air flow
Plate evaporator •
Microprocessor control system •
Step-step condensing control •
Pump-Down stop •
Differential pressure switch •
on water side
Door lock main switch •
LNO Kit for about a 6 dB(A) noise •
pressure level reduction
Modulating condensing control •
Pumping group with 1 or 2 pumps •
Water tank •
Partial or total heat reclaim •
Mechanical flow switch •
Spring antivibration holders •
RS232C-RS422-RS485 serial line •
Outdoor air temperature sensor •
UDT, SQL or ASME VIII Div.1 approvals •
OPTI
ONAL
UNICO.SCROLL.C.STD “G”R407C • 20 ÷ 112 kW
The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.
CentriCentrifugal fan version for
indoor and/or ducted
installations.
HIGH
LIGHT
S
Made2LastHousing designed to last
in time and in any
weather condition.
SpaceSaverInternal components layout
allows full frontal
inspection and maintenance
operations.
Version available with R134a refrigerant chargesee page 274
132 RC GROUP SpA • General Catalogue • 155.EN.0504
UNICO.SCROLL.C.ELN “G” - MODELSizeCooling capacity (1) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgMean sound pressure level (2) dB(A)
UNICO.SCROLL.C.ELN “G” - MODELSizeCooling capacity (1) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgMean sound pressure level (2) dB(A)
21.Z1 25.Z1 32.Z1 37.Z1 50.Z1 61.Z1G3 G3 G3 G5 G5 G5
18,5 21,5 28,3 32,9 45 56,41 1 1 1 1 11 1 1 1 1 1
2000 2000 2000 2600 2600 26001040 1040 1040 1200 1200 12002010 2010 2010 2240 2240 2240590 590 630 840 900 91047 49 51 53 54 58
36.Z2 42.Z2 50.Z2 64.Z2 74.Z2 87.Z2 100.Z2 124.Z2G5 G5 G5 G5 G7 G8 G8 G8
30,6 36,3 42,9 55,9 63,2 82,7 91,6 109,32 2 2 2 2 2 2 22 2 2 2 2 2 2 2
2600 2600 2600 2600 3600 5170 5170 51701200 1200 1200 1200 1290 1290 1290 12902240 2240 2240 2240 2010 2050 2050 2050860 880 920 970 1360 1850 1910 197052 55 54 58 55 56 56 56
(1) Data referred to chilled water temperature at 12/7°C; condenser air inlet at 35°C.(2) Mean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 400.3.50+N
Liquid chillers with centrifugal fansTE
CHNI
CAL D
ATA
UNICO.SCROLL.C.ELN “G”Air cooled packaged liquid chillers in extremely low noise version equipped with Scroll
compressors and centrifugal fans. Casing type: “G”.
IDEN
TIFIC
ATIO
N
ELN Range (Extremely low noise)Over 20 years of experience in sound reduction techniques together with SCROLL technology enable RC Group to grant excellent
sound emission levels for this equipment.
The result as for all ELN range chillers is achieved by a specific design philosophy concentrated on removing the sound emissions
at "source", without using "bolt-on" acoustic kits that result in detrimental product efficiency, maintenance and durability.
133RC GROUP SpA • General Catalogue • 155.EN.0504
CHAR
ACTE
RIST
ICSHousing with aluminium profile frame •
with galvanized steel sheet panels
externally coated with PVC film
Main components housed in a •
technical compartment separated
from the air flow
Plate evaporator •
Microprocessor control system •
Modulating condensing control •
Pump-Down stop •
Differential pressure switch •
on water side
Door lock main switch •
Pumping group with 1 or 2 pumps •
Water tank •
Partial or total heat reclaim •
Mechanical flow switch •
Spring antivibration holders •
RS232C-RS422-RS485 serial line •
Outdoor air temperature sensor •
UDT, SQL or ASME VIII Div.1 approvals •
OPTI
ONAL
UNICO.SCROLL.C.ELN “G”R407C • 18 ÷ 110 kW
The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.
QuickStartThe supply includes whatever
is needed for a correct unit
working.
For the start-up the units only
need electrical, hydraulic and
cooling connections for a
complete installation in
compliance with all the current
norms.
HIGH
LIGHT
S
ZytelThe special compressor air
supply pipelines made of
patented plastic material
avoid the vibrations
transmission from the
compressor to the
condensing coils reducing the
total noise emission and
avoiding the early materials
decay.
Version available with R134a refrigerant chargesee page 274
134 RC GROUP SpA • General Catalogue • 155.EN.0504
UNICO.RECIP.C.STD “G” - MODELSizeCooling capacity (1) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgMean sound pressure level (2) dB(A)
UNICO.RECIP.C.STD “G” - MODELSizeCooling capacity (1) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgMean sound pressure level (2) dB(A)
142.F2 188.F2 220.F2G7 G7 G8
130,5 165,6 193,82 2 22 2 2
3600 3600 51701290 1290 12902010 2010 20501795 1930 238071 71 74
260.F2 300.F2G8 G8237 264,62 22 2
5170 51701290 12902050 20502740 277076 77
(1) Data referred to chilled water temperature at 12/7°C; condenser air inlet at 35°C.(2) Mean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 400.3.50+N
Liquid chillers with centrifugal fansTE
CHNI
CAL D
ATA
IDEN
TIFIC
ATIO
N UNICO.RECIP.C.STD “G”Air cooled packaged liquid chillers equipped with reciprocating compressors and centrifugal fans.
Casing type: “G”.
AdaptiveRangeA wide range of versions and optional for advanced air conditioning systems in big areas and
cooling plants in the industrial field.
135RC GROUP SpA • General Catalogue • 155.EN.0504
CHAR
ACTE
RIST
ICSHousing with aluminium profile frame •
with galvanized steel sheet panels
externally coated with PVC film
Main components housed in a •
technical compartment separated
from the air flow
Shell and tube evaporator •
Microprocessor control system •
Step-step condensing control •
Pump-Down stop •
Step-step cooling capacity control •
Door lock main switch •
LNO Kit for about a 6 dB(A) noise •
pressure level reduction
Modulating condensing control •
Pumping group with 1 or 2 pumps •
Water tank •
Partial or total heat reclaim •
Part winding compressors •
starting system
Mechanical flow switch •
Spring antivibration holders •
RS232C-RS422-RS485 serial line •
Outdoor air temperature sensor •
UDT, SQL or ASME VIII Div.1 approvals •
OPTI
ONAL
UNICO.RECIP.C.STD “G”R407C • 130 ÷ 265 kW
The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.
PumpStationA complete built-in pumping station (without size increase), equipped
with instruments and safety devices totally integrated with the unit
control system in order to emphasize the RC PROACTIVE system;
possibility to integrate PumpStation with water tank without any
increase in footprint.
HIGH
LIGHT
S
BufferTankWater tank to increase plant
inertia with an extreme
reduction of compressors
start-up, harmful for their
reliability and endurance.
Version available with R134a refrigerant chargesee page 274
136 RC GROUP SpA • General Catalogue • 155.EN.0504
UNICO.RECIP.C.ELN “G” - MODELSizeCooling capacity (1) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgMean sound pressure level (2) dB(A)
142.F2 188.F2 220.F2G8 G8 G8131 165,8 196,32 2 22 2 2
5170 5170 51701290 1290 12902050 2050 20502140 2300 239560 61 67
(1) Data referred to chilled water temperature at 12/7°C; condenser air inlet at 35°C.(2) Mean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 400.3.50+N
Liquid chillers with centrifugal fansTE
CHNI
CAL D
ATA
UNICO.RECIP.C.ELN “G”Air cooled packaged liquid chillers in extremely low noise version equipped with reciprocating
compressors and centrifugal fans. Casing type: “G”.
IDEN
TIFIC
ATIO
N
ELN Range (Extremely low noise)For over 20 years RC Group has offered a complete range of units designed specifically to provide the "lowest noise
emission" equipment on the market.
The design and continuous development of the ELN range has avoided using "bolt-on" acoustic kits, adding weight and
reducing the serviceability of the equipment but instead has concentrated on removing the sound emissions at "source".
This one solution grants : high efficiency, extremely low sound emissions and easy maintenance, no need to remove
heavy noise reduction kits or acoustic barriers. The performance and durability of the RC Group solution lasts with
time, unlike that of the materials of the "bolt-on" sound reduction kits that can decay over time.
137RC GROUP SpA • General Catalogue • 155.EN.0504
CHAR
ACTE
RIST
ICSHousing with aluminium profile frame •
with galvanized steel sheet panels
externally coated with PVC film
Main components housed in a •
technical compartment separated
from the air flow
Shell and tube evaporator •
Microprocessor control system •
Modulating condensing control •
Pump-Down stop •
Step-step cooling capacity control •
Door lock main switch •
Pumping group with 1 or 2 pumps •
Water tank •
Partial or total heat reclaim •
Part winding compressors •
starting system
Mechanical or electronic flow switch •
Spring antivibration holders •
RS232C-RS422-RS485 serial line •
Outdoor air temperature sensor •
UDT, SQL or ASME VIII Div.1 approvals •
OPTI
ONAL
UNICO.RECIP.C.ELN “G”R407C • 130 ÷ 200 kW
The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.
ServiceFastCompressors, electric board
and electronic control system
housed in a technical
compartment separated from
the air flow to allow standard
maintenance with the unit in
operation.
HIGH
LIGHT
S
MateBuilt-in condensing control system for a stepless air flow modulation
through patented system of dampers directly set on the fans outlet.
Version available with R134a refrigerant chargesee page 274
138 RC GROUP SpA • General Catalogue• 155.EN.0504
RC GROUP liquid chillers: wide range of units in terms of models, compressors, refrigerants.
FREE-COOLING LIQUID CHILLERSLiquid chillers with built-in indirect SRC free-cooling system are specifically designed to reduce energy consumption wherecooling energy is required even in wintertime and mid-season, as required in air conditioning systems for information technology,
communication and industrial cooling.The units are equipped with a combined system to use outdoor air for water free cooling or precooling.Thanks to a proprietary control logic developed by RC through a 30-year experience in production of these chillers, the energy savingachieved through this type of chillers is always the maximum allowed by the outdoor air temperature, without any compromise.These chillers are available also in OPTIMIZER version, internationally patented, able to multiply the energy savings achieved throughindirect free-cooling solutions specially in areas with a temperate climate. Also this range of units is available both with axial andcentrifugal fans for indoor installations.
ELN RANGE (EXTREMELY LOW NOISE)For over 20 years RC Group has offered a standard catalogued range of units designed specifically to provide the "lowest noiseemission" equipment on the market.The design and continuous development of the ELN range has avoided using "bolt-on" acoustic kits, adding weight and reducing theserviceability of the equipment but instead has concentrated on removing the sound emissions at "source".By careful selection of matched components and innovative design of the condensing coil surface and airflow distribution, the ELN rangehas evolved into one of the quietest and thermally efficient Packaged Chillers in today's market place.This one solution grants : high efficiency, extremely low sound emissions and easy maintenance, no need to remove heavy noise reductionkits or acoustic barriers. The performance and durability of the RC Group solution lasts with time, unlike that of the materials of the"bolt-on" sound reduction kits that can decay over time.All RC Group chillers are available in the ELN range, including versions with axial or centrifugal fans.
PLAN
T TY
PEAir cooled free-cooling liquid chillers
139RC GROUP SpA • General Catalogue • 155.EN.0504
MAXIMO.SCROLL.A.STD “G” • R407C • 21 ÷ 127 kWFree-cooling liquid chillers with scroll compressors.
MAXIMO.SCROLL.A.ELN “G” • R407C • 22 ÷ 120 kWExtremely low noise free-cooling liquid chillers with scroll compressors.
MAXIMO.RECIP.A.STD “G” • R407C • 146 ÷ 412 kWFree-cooling liquid chillers with reciprocating compressors.
MAXIMO.RECIP.A.ELN “G” • R407C • 137 ÷ 292 kWExtremely low noise free-cooling liquid chillers
with reciprocating compressors.
MAXIMO.RECIP.A.STD “U” • R407C • 486 ÷ 1040 kWFree-cooling liquid chillers with reciprocating semihermetic compressors.
MAXIMO.RECIP.A.ELN “U” • R407C • 323 ÷ 617 kWExtremely low noise free-cooling liquid chillers
with reciprocating compressors.
MAXIMO.RECIP.A.STD “W” • R407C • 1220 ÷ 1610 kWFree-cooling liquid chillers with reciprocating compressors.
MAXIMO.SCREW.A.STD “G” • R407C • 249 ÷ 392 kWFree-cooling liquid chillers with screw compressors.
MAXIMO.SCREW.A.ELN “G” • R407C • 261 ÷ 300 kWExtremely low noise free-cooling liquid chillers with screw compressors.
MAXIMO.SCREW.A.STD “U” • R407C • 472 ÷ 1096 kWFree-cooling liquid chillers with screw compressors.
MAXIMO.SCREW.A.ELN “U” • R407C • 366 ÷ 802 kWExtremely low noise free-cooling liquid chillers with screw compressors.
MAXIMO.SCREW.A.STD “W” • R407C • 1399 ÷ 1869 kWFree-cooling liquid chillers with screw semihermetic compressors.
MAXIMO.SCROLL.C.STD “G” • R407C • 21 ÷ 122 kWFree-cooling liquid chillers with scroll compressors.
MAXIMO.SCROLL.C.ELN “G” • R407C • 22 ÷ 121 kWExtremely low noise free-cooling liquid chillers with scroll compressors.
MAXIMO.RECIP.C.STD “G” • R407C • 140 ÷ 288 kWFree-cooling liquid chillers with reciprocating compressors.
MAXIMO.RECIP.C.ELN “G” • R407C • 138 ÷ 214 kWExtremely low noise free-cooling liquid chillers with reciprocating
compressors.
140 AXIAL FANS
142
144
146
148
150
152
154
156
158
160
162
164 CENTRIFUGAL FANS
166
168
170
Air cooled free-coolingliquid chillers
INDE
X
140 RC GROUP SpA • General Catalogue• 155.EN.0504
MAXIMO.SCROLL.A.STD “G” - MODELSizeCooling capacity (1) kWFree-Cooling capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgMean sound pressure level (3) dB(A)
MAXIMO.SCROLL.A.STD “G” - MODELSizeCooling capacity (1) kWFree-Cooling capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgMean sound pressure level (3) dB(A)
21.Z1 25.Z1 32.Z1 37.Z1 50.Z1 61.Z1G0 G0 G2 G2 G4 G4
21,6 23,8 32,5 39,5 53 63,519,2 19,5 29 38,1 49,9 51,5
1 1 1 1 1 11 1 1 1 1 1
1150 1150 2000 2000 2600 26001100 1100 1250 1250 1410 14101640 1640 1690 1690 1690 1690370 370 545 615 840 87062 62 62 64 64 64
36.Z2 42.Z2 50.Z2 64.Z2 74.Z2 87.Z2 100.Z2 124.Z2G2 G2 G4 G4 G6 G6 G6 G7
37,1 42,7 50,5 64,1 74,2 94,8 105,2 126,737,6 38,7 49,5 58 70,2 87,9 89,7 117,4
2 2 2 2 2 2 2 22 2 2 2 2 2 2 2
2000 2000 2600 2600 3600 3600 3600 36001250 1250 1410 1410 1560 1560 1560 15601690 1690 1690 1690 1690 1690 1690 2215650 660 890 940 1230 1380 1440 158064 64 64 65 65 66 66 66
(1) Data referred to chilled water temperature at 15/10°C; outdoor air temperature at 35°C.(2) Data referred to inlet chilled water temperature at 15°C; outdoor air temperature at 2,5°C.(3) Mean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 400.3.50+N
Free-cooling liquid chillers with axial fansTE
CHNI
CAL D
ATA
IDEN
TIFIC
ATIO
N MAXIMO.SCROLL.A.STD “G”Air cooled packaged liquid chillers equipped with energy saving free-cooling SCR system, Scroll compressors
and axial fans. Casing type: “G”.
SCR&MP99 (RC GROUP free-cooling system)RC revealed to be a pioneer in energy saving field applied to air cooled liquid chillers by developing in 1979 the first
(absolutely) chiller with integrated free-cooling system called SCR.
Nowadays RC is the manufacturer with the longest experience in this specific field with thousand of installations all over
the world, from Siberia to South Africa, from Buenos Aires to Beijing through Madrid and London.
MAXIMO.SCROLL represents the latest generation of chillers with free-cooling SCR system and combines RC peerless
experience with SCROLL latest generation technology to grant the quickest return of the investment.
141RC GROUP SpA • General Catalogue • 155.EN.0504
CHAR
ACTE
RIST
ICSHousing with aluminium profile frame •
with galvanized steel sheet panels
externally coated with PVC film
Main components housed in a •
technical compartment separated
from the air flow
Plate evaporator •
Free-cooling system •
Microprocessor control system •
Modulating condensing control •
Pump-Down stop •
Differential pressure switch •
on water side
Door lock main switch •
Optimizer system •
LNO Kit for about a 6 dB(A) noise •
pressure level reduction
Pumping group with 1 or 2 pumps •
Water tank •
Partial heat reclaim •
Mechanical flow switch •
Spring antivibration holders •
RS232C-RS422-RS485 serial line •
UDT, SQL or ASME VIII Div.1 approvals •
OPTI
ONAL
MAXIMO.SCROLL.A.STD “G”R407C • 21 ÷ 127 kW
The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.
RCProactiveMP99 microprocessor control and
monitoring system with
technology owned by RC
PROACTIVE, designed to grant
continuity of work even in
emergency situations.
HIGH
LIGHT
S
QuickStartWhatever is needed for a correct
operation is built-in.
Electrical and water connections
only are needed at start-up for a
complete installation in full
compliance with all the current
norms.
Version available with R134a refrigerant chargesee page 274
142 RC GROUP SpA • General Catalogue• 155.EN.0504
MAXIMO.SCROLL.A.ELN “G” - MODELSizeCooling capacity (1) kWFree-Cooling capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgMean sound pressure level (3) dB(A)
MAXIMO.SCROLL.A.ELN “G” - MODELSizeCooling capacity (1) kWFree-Cooling capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgMean sound pressure level (3) dB(A)
21.Z1 25.Z1 32.Z1 37.Z1 50.Z1 61.Z1G2 G2 G4 G4 G5 G5
22,2 24,6 32,1 38,4 52,7 61,523 23,4 29,9 36,8 52,5 53,91 1 1 1 1 11 1 1 1 1 1
2000 2000 2600 2600 2600 26001250 1250 1410 1410 1410 14101690 1690 1690 1690 2240 2240545 545 750 800 1090 109551 51 55 52 55 55
36.Z2 42.Z2 50.Z2 64.Z2 74.Z2 87.Z2 100.Z2 124.Z2G4 G4 G5 G7 G7 G7 G7 G836 42,8 50,1 63,4 74,6 90,1 99,4 120,1
36,3 41,1 52 62,5 77,8 87,6 89,1 120,22 2 2 2 2 2 2 22 2 2 2 2 2 2 2
2600 2600 2600 3600 3600 3600 3600 51701410 1410 1410 1560 1560 1560 1560 15901690 1690 2240 2215 2215 2215 2215 2155890 910 1080 1430 1550 1650 1710 207052 55 55 51 55 51 51 53
(1) Data referred to chilled water temperature at 15/10°C; outdoor air temperature at 35°C.(2) Data referred to inlet chilled water temperature at 15°C; outdoor air temperature at 2,5°C.(3) Mean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 400.3.50+N
Free-cooling liquid chillers with axial fansTE
CHNI
CAL D
ATA
IDEN
TIFIC
ATIO
N MAXIMO.SCROLL.A.ELN “G”Air cooled packaged liquid chillers in extremely low noise version equipped with energy saving free-cooling
SCR system, Scroll compressors and axial fans. Casing type: “G”.
ELN Range (Extremely low noise)For over 20 years RC Group has offered a complete range of units designed specifically to provide the "lowest noise
emission" equipment on the market.
The design and continuous development of the ELN range has avoided using "bolt-on" acoustic kits, adding weight and
reducing the serviceability of the equipment but instead has concentrated on removing the sound emissions at "source".
This one solution grants : high efficiency, extremely low sound emissions and easy maintenance, no need to remove heavy
noise reduction kits or acoustic barriers. The performance and durability of the RC Group solution lasts with time, unlike
that of the materials of the "bolt-on" sound reduction kits that can decay over time.
143RC GROUP SpA • General Catalogue • 155.EN.0504
CHAR
ACTE
RIST
ICSHousing with aluminium profile frame •
with galvanized steel sheet panels
externally coated with PVC film
Main components housed in a •
technical compartment separated
from the air flow
Plate evaporator •
Free-cooling system •
Microprocessor control system •
Modulating condensing control •
coupled with flooding system
Pump-Down stop •
Differential pressure switch •
on water side
Door lock main switch •
Optimizer system •
Pumping group with 1 or 2 pumps •
Water tank •
Partial heat reclaim •
Mechanical flow switch •
Spring antivibration holders •
RS232C-RS422-RS485 serial line •
UDT, SQL or ASME VIII Div.1 approvals •
OPTI
ONAL
MAXIMO.SCROLL.A.ELN “G”R407C • 22 ÷ 120 kW
The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.
HIGH
LIGHT
S
PumpStationA complete built-in pumping
station (without size
increase), equipped with
instruments and safety
devices totally integrated
with the unit control system
in order to emphasize the RC
PROACTIVE system.
ZytelThe special compressor discharge
piped made of patented plastic
material avoid the vibrations
transmission from the compressor
to the condensing coils reducing the
total noise emission and avoiding
the early materials decay.
Version available with R134a refrigerant chargesee page 274
144 RC GROUP SpA • General Catalogue• 155.EN.0504
MAXIMO.RECIP.A.STD “G” - MODELSizeCooling capacity (1) kWFree-Cooling capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgMean sound pressure level (3) dB(A)
MAXIMO.RECIP.A.STD “G” - MODELSizeCooling capacity (1) kWFree-Cooling capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgMean sound pressure level (3) dB(A)
142.F2 188.F2 220.F2 260.F2 300.F2G7 G8 G8 G8 G8
146,2 183,1 216,4 259,5 285,7117,2 173,6 213,2 220 223,1
2 2 2 2 22 2 2 2 2
3600 5170 5170 5170 51701560 1590 1590 1590 15902115 2155 2155 2215 22152095 2310 2465 2830 286066 66 67 73 73
320.S2 350.F2 385.S2 440.S2G9 G9 G9 G9
325,9 354,8 377,2 412,1254,8 257,8 274,6 275,8
2 2 2 22 2 2 2
5900 5900 5900 59002070 2070 2070 20702470 2470 2470 24705130 4430 5170 518072 72 72 72
(1) Data referred to chilled water temperature at 15/10°C; outdoor air temperature at 35°C.(2) Data referred to inlet chilled water temperature at 15°C; outdoor air temperature at 2,5°C.(3) Mean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 400.3.50+N
Free-cooling liquid chillers with axial fansTE
CHNI
CAL D
ATA
IDEN
TIFIC
ATIO
N MAXIMO.RECIP.A.STD “G”Air cooled packaged liquid chillers equipped with energy saving free-cooling SCR system, reciprocating
compressors and axial fans. Casing type: “G”.
SCR&MP99 (RC GROUP free-cooling system)MAXIMO chillers control system is based on a RC proprietary software and it is the sum of RC experiences achieved
through thousand of installations all over the world, from Siberia to South Africa, from Buenos Aires to Beijing through
Madrid and London.
The possibility to test SCR system directly in numerous and different climatic situations and in various application fields
(precision and comfort air conditioning, industrial and process cooling for chemical, pharmaceutical, food and mechanical
industry) allowed RC to develop a specific know-how which is not easily achievable by other companies working in the
same field.
This solution brings energy savings that cannot be matched by competitors equipment.
145RC GROUP SpA • General Catalogue • 155.EN.0504
CHAR
ACTE
RIST
ICSHousing with aluminium profile frame •
with galvanized steel sheet panels
externally coated with PVC film
Main components housed in a •
technical compartment separated
from the air flow
Shell and tube evaporator •
Free-cooling system •
Microprocessor control system •
Modulating condensing control •
coupled with flooding system
Pump-Down stop •
Part-Winding compressors •
starting system (S)
Step-step cooling capacity control •
Door lock main switch •
Optimizer system •
LNO Kit for about a 6 dB(A) noise •
pressure level reduction
Pumping group with 1 or 2 pumps •
Water tank •
Partial heat reclaim •
Part-Winding compressors •
starting system (F)
Mechanical flow switch •
Spring antivibration holders •
RS232C-RS422-RS485 serial line •
UDT, SQL or ASME VIII Div.1 approvals •
OPTI
ONAL
MAXIMO.RECIP.A.STD “G”R407C • 146 ÷ 412 kW
The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.
MyNoiseSolutions range (STD-LNO) conceived to allow the selection directly
from the catalogue of the most suitable product for the specific
legislative or environmental demands regarding the noise emission
control.
HIGH
LIGHT
S
MateIntegrated condensing
control system for a
stepless speed modulation
of condenser fans.
SCR&MP99The high energy saving of SCR
system is obtained through the RC
proprietary software which
optimizes total or partial free-
cooling cycles according to the
specific climatic and inner load
conditions.
Version available with R134a refrigerant chargesee page 274
146 RC GROUP SpA • General Catalogue• 155.EN.0504
MAXIMO.RECIP.A.ELN “G” - MODELSizeCooling capacity (1) kWFree-Cooling capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgMean sound pressure level (3) dB(A)
MAXIMO.RECIP.A.ELN “G” - MODELSizeCooling capacity (1) kWFree-Cooling capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgMean sound pressure level (3) dB(A)
142.F2 188.F2 220.F2G8 G8 G8
137,6 177,2 207,1123 145,8 168,82 2 22 2 2
5170 5170 51701590 1590 15902155 2155 21552225 2370 246553 53 56
260.F2 300.F2G9 G9
256,6 292,1196,7 219,5
2 22 2
5900 59002070 20702470 24703270 339058 61
(1) Data referred to chilled water temperature at 15/10°C; outdoor air temperature at 35°C.(2) Data referred to inlet chilled water temperature at 15°C; outdoor air temperature at 2,5°C.(3) Mean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 400.3.50+N
Free-cooling liquid chillers with axial fansTE
CHNI
CAL D
ATA
IDEN
TIFIC
ATIO
N MAXIMO.RECIP.A.ELN “G”Air cooled packaged liquid chillers in extremely low noise version equipped with energy saving free-cooling
SCR system, reciprocating compressors and axial fans. Casing type: “G”.
ELN Range (Extremely low noise)Highest energy saving and lowest sound emission together in the same product.
Thanks to MAXIMO ELN it is possible to take advantage of SCR indirect free-cooling system even in those situations requiring the
lowest noise levels in order to meet specific legislative or environmental demands.
The result as for all ELN range chillers is achieved by a specific design philosophy concentrated on removing the sound emissions
at "source", without using "bolt-on" acoustic kits.
This solution grants continuity of performance in both sound level and cooling capacity. The system is managed by PROACTIVE
logic as all RC microprocessor based control systems.
147RC GROUP SpA • General Catalogue • 155.EN.0504
CHAR
ACTE
RIST
ICSHousing with aluminium profile frame •
with galvanized steel sheet panels
externally coated with PVC film
Main components housed in a •
technical compartment separated
from the air flow
Shell and tube evaporator •
Free-cooling system •
Microprocessor control system •
Modulating condensing control •
coupled with flooding system
Pump-Down stop •
Step-step cooling capacity control •
Door lock main switch •
Optimizer system •
Pumping group with 1 or 2 pumps •
Water tank •
Partial heat reclaim •
Part-Winding compressors •
starting system
Mechanical flow switch •
Spring antivibration holders •
RS232C-RS422-RS485 serial line •
UDT, SQL or ASME VIII Div.1 approvals •
OPTI
ONAL
MAXIMO.RECIP.A.ELN “G”R407C • 137 ÷ 292 kW
The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.
SleepWellProprietary software
for lowest noise
emission working
during the night.
HIGH
LIGHT
S
ServiceFastCompressors, electric board
and electronic control system
housed in a technical
compartment separated from
the air flow to allow standard
maintenance with the unit in
operation.
Version available with R134a refrigerant chargesee page 274
148 RC GROUP SpA • General Catalogue• 155.EN.0504
Patent
MAXIMO.RECIP.A.STD “U” - MODELSizeCooling capacity (1) kWFree-Cooling capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgMean sound pressure level (3) dB(A)
MAXIMO.RECIP.A.STD “U” - MODELSizeCooling capacity (1) kWFree-Cooling capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgMean sound pressure level (3) dB(A)
495.S2 550.S2 600.S2 660.S2U10 U10 U11 U11484 522 597,4 635,9
376,5 380,5 472,9 476,92 2 2 22 2 2 2
5500 5500 6490 64902385 2385 2385 23852430 2430 2430 24305430 5440 6500 650075 75 75 75
770.S2 880.S2 990.S2 1100.S2U12 U13 U14 U14746 848,7 968,6 1040,5
561,3 655,5 753,1 756,92 2 2 22 2 2 2
7480 8470 9460 94602385 2385 2385 23852430 2430 2430 24307860 8840 9310 932076 77 77 77
(1) Data referred to chilled water temperature at 15/10°C; outdoor air temperature at 35°C.(2) Data referred to inlet chilled water temperature at 15°C; outdoor air temperature at 2,5°C.(3) Mean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 400.3.50+N
Free-cooling liquid chillers with axial fansTE
CHNI
CAL D
ATA
IDEN
TIFIC
ATIO
N MAXIMO.RECIP.A.STD “U”Air cooled packaged liquid chillers equipped with energy saving free-cooling SCR system, reciprocating
compressors and axial fans. Casing type: “U”.
Optimizer®RC Group, once again, has been the first company of its field to manufacture free-cooling chillers up to 1.000 Kw. The
leadership in this market segment is confirmed by a large number of units of this size installed in the last years all over
Europe.
Thanks to the experience reached gradually in these “huge” installations, RC designed and patented a new system to
extend SCR free-cooling system use also in temperate climate areas or to increase the energy savings in cold areas.
The so called OPTIMIZER system is composed by a set of innovations at a hydraulic connections and control software
level. OPTIMIZER is internationally patented.
149RC GROUP SpA • General Catalogue • 155.EN.0504
CHAR
ACTE
RIST
ICSHousing with aluminium profile frame •
with galvanized steel sheet panels
externally coated with PVC film
Main components housed in a •
technical compartment separated
from the air flow
Shell and tube evaporator •
Free-cooling system •
Microprocessor control system •
Modulating condensing control •
coupled with flooding system
Pump-Down stop •
Part-Winding compressors •
starting system
Step-step cooling capacity control •
Door lock main switch •
Optimizer system •
LNO Kit for about a 6 dB(A) noise •
pressure level reduction
Pumping group with 1 or 2 pumps •
Water tank •
Partial heat reclaim •
Mechanical flow switch •
Spring antivibration holders •
RS232C-RS422-RS485 serial line •
UDT, SQL or ASME VIII Div.1 approvals •
OPTI
ONAL
MAXIMO.RECIP.A.STD “U”R407C • 485 ÷ 1040 kW
The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.
AdaptiveRangeA complete range of models and optional designed for high air
conditioning systems in large installations and in industrial cooling.
HIGH
LIGHT
S
GlycolFreeFree-cooling integrated system for plants where
antifreezer are not allowed.
Version available with R134a refrigerant chargesee page 274
150 RC GROUP SpA • General Catalogue• 155.EN.0504
MAXIMO.RECIP.A.ELN “U” - MODELSizeCooling capacity (1) kWFree-Cooling capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgMean sound pressure level (3) dB(A)
MAXIMO.RECIP.A.ELN “U” - MODELSizeCooling capacity (1) kWFree-Cooling capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgMean sound pressure level (3) dB(A)
320.S2 350.F2 385.S2 440.S2U10 U10 U10 U11323 351,3 371,1 421
299,9 304,4 294,6 358,12 2 2 22 2 2 2
5500 5500 5500 64902385 2385 2385 23852430 2430 2430 24305280 4580 5310 620062 62 62 62
495.S2 550.S2 600.S2 660.S2U12 U12 U12 U12
493,4 532,5 580,6 617,7427,5 432,8 439,2 443,2
2 2 2 22 2 2 2
7480 7480 7480 74802385 2385 2385 23852430 2430 2430 24307470 7480 7660 766062 62 62 62
(1) Data referred to chilled water temperature at 15/10°C; outdoor air temperature at 35°C.(2) Data referred to inlet chilled water temperature at 15°C; outdoor air temperature at 2,5°C.(3) Mean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 400.3.50+N
Free-cooling liquid chillers with axial fansTE
CHNI
CAL D
ATA
IDEN
TIFIC
ATIO
N MAXIMO.RECIP.A.ELN “U”Air cooled packaged liquid chillers in extremely low noise version equipped with energy saving free-cooling
SCR system, reciprocating compressors and axial fans. Casing type: “U”.
ELN Range (Extremely low noise)An extremely compact chilled water production unit with a noise level meeting the most strict demands.
MAXIMO.RECIP.A.ELN “U”, range up to 600 Kw including SCR free-cooling system and RC ELN technology.
151RC GROUP SpA • General Catalogue • 155.EN.0504
CHAR
ACTE
RIST
ICSHousing with aluminium profile frame •
with galvanized steel sheet panels
externally coated with PVC film
Main components housed in a •
technical compartment separated
from the air flow
Shell and tube evaporator •
Free-cooling system •
Microprocessor control system •
Modulating condensing control •
coupled with flooding system
Pump-Down stop •
Part-Winding compressors •
starting system
Step-step cooling capacity control •
Door lock main switch •
Optimizer system •
LNO Kit for about a 6 dB(A) noise •
pressure level reduction
Pumping group with 1 or 2 pumps •
Water tank •
Partial heat reclaim •
Mechanical flow switch •
Spring antivibration holders •
RS232C-RS422-RS485 serial line •
UDT, SQL or ASME VIII Div.1 approvals •
OPTI
ONAL
MAXIMO.RECIP.A.ELN “U”R407C • 323 ÷ 617 kW
The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.
Easy@ServeAll components are
accessible through handy
hinged panels equipped
with antiwind lock, without
removal of heavy noise
deading boxes.
HIGH
LIGHT
S
PumpStationA complete built-in pumping station
(without size increase), equipped
with instruments and safety devices
totally integrated with the unit
control system in order to emphasize
the RC PROACTIVE system.
Version available with R134a refrigerant chargesee page 274
PatentOptimizer®Patented OPTIMIZER system for
variable water flow or; thanks to
this solution it is possible to
extend the application to
temperate climate areas and/or
to appreciably increase the
energy savings obtained through
indirect free-cooling systems.
152 RC GROUP SpA • General Catalogue• 155.EN.0504
MAXIMO.RECIP.A.STD “W” - MODELSizeCooling capacity (1) kWFree-Cooling capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgMean sound pressure level (3) dB(A)
MAXIMO.RECIP.A.STD “W” - MODELSizeCooling capacity (1) kWFree-Cooling capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgMean sound pressure level (3) dB(A)
1210.S3 1320.S3 1420.S3W21 W21 W22
1220,5 1292,3 1429,61058,4 1059,3 1188,4
3 3 33 3 3
10800 10800 118702350 2350 23502610 2610 2610
13650 13815 1489085 85 85
1530.S3 1640.S3W22 W23
1507,7 1612,81197,1 1309,1
3 33 3
11870 129402350 23502610 2610
14895 1582185 85
(1) Data referred to chilled water temperature at 15/10°C; outdoor air temperature at 35°C.(2) Data referred to inlet chilled water temperature at 15°C; outdoor air temperature at 2,5°C.(3) Mean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 400.3.50+N
Free-cooling liquid chillers with axial fansTE
CHNI
CAL D
ATA
IDEN
TIFIC
ATIO
N MAXIMO.RECIP.A.STD “W”Air cooled packaged liquid chillers equipped with energy saving free-cooling SCR system, reciprocating
compressors and axial fans. Casing type: “W”.
Maximo&DualThe competitors start proposing free-cooling chillers up to 1.000 Kw....... once again RC redefines the field
limits.
MAXIMO W, a range of chillers equipped with SCR system supplying up to 1.610 Kw in a single unit. The range
is in the catalogue, as always, and the reliability is supported by the experience of many units installed on
site. Since many years RC has been developing its know-how on systems, management and components level.
MAXIMO W is equipped with RC Group DUAL compressors which grant up to 550 Kw cooling capacity; the
biggest reciprocating compressor available today on the market.
153RC GROUP SpA • General Catalogue • 155.EN.0504
CHAR
ACTE
RIST
ICSHousing made of epoxy painted •
galvanized steel sheet
Shell and tube evaporator •
Free-cooling system •
Microprocessor control system •
Modulating condensing control •
coupled with flooding system
Pump-Down stop •
Part-Winding compressors •
starting system
Step-step cooling capacity control •
Door lock main switch •
LNO Kit for about a 6 dB(A) noise •
pressure level reduction
Partial heat reclaim •
Mechanical flow switch •
Spring antivibration holders •
RS232C-RS422-RS485 serial line •
UDT, SQL or ASME VIII Div.1 approvals •
OPTI
ONAL
MAXIMO.RECIP.A.STD “W”R407C • 1220 ÷ 1610 kW
The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.
CoolingDensityPlusOptimization of internal layout to achieve the best ratio between
footprint and cooling capacity.HIGH
LIGHT
S
Version available with R134a refrigerant chargesee page 274
Patent
Dual®RC Group DUAL compressors are equipped with innovative
technologies such as: valves in composite material (covered by
international patent), specifically designed to be used with ester
oils and green refrigerants; compressor built-in filters section is
easy to inspect and maintain; internal spaces are designed to
maximize the efficiency both at full load and at partial loads;
proprietary unloading system; a wide range of innovative design
has been used in the liquid dynamic handling in order to reduce
vibration transmission and overall sound level.
154 RC GROUP SpA • General Catalogue• 155.EN.0504
MAXIMO.SCREW.A.STD “G” - MODELSizeCooling capacity (1) kWFree-Cooling capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgMean sound pressure level (3) dB(A)
MAXIMO.SCREW.A.STD “G” - MODELSizeCooling capacity (1) kWFree-Cooling capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgMean sound pressure level (3) dB(A)
230.V1 280.V1 330.V1 370.V1G8 G9 G9 G9
249,1 316,3 363,8 392,3229,5 310,9 310,8 313,8
1 1 1 11 1 1 1
5170 5900 5900 59001590 2070 2070 20702155 2470 2470 24702825 4255 4400 442070 71 71 71
200.V2 240.V2 280.V2 320.V2G8 G8 G9 G9
216,4 265,5 309,2 350,7228,5 230,4 303,4 315,9
2 2 2 22 2 2 2
5170 5170 5900 59001590 1590 2070 20702155 2155 2470 24702860 2870 4245 469071 71 72 72
(1) Data referred to chilled water temperature at 15/10°C; outdoor air temperature at 35°C.(2) Data referred to inlet chilled water temperature at 15°C; outdoor air temperature at 2,5°C.(3) Mean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 400.3.50+N
Free-cooling liquid chillers with axial fansTE
CHNI
CAL D
ATA
IDEN
TIFIC
ATIO
N MAXIMO.SCREW.A.STD “G”Air cooled packaged liquid chillers equipped with energy saving free-cooling SCR system, screw compressors
and axial fans. Casing type: “G”.
RCProactiveAll MAXIMO range is equipped with microprocessors systems provided with RC PROACTIVE logic conceived to grant
continuity of work even in emergency situations.
For instance: in case of a restart after a possible stop of the units due to a blackout, the proprietary RESTART system
(PROACTIVE logic integrated system), activates a restart procedure granting the chiller in operation even with a return
water high temperature. Usually this situation would cause an immediate stop of the chiller (complete stop with manual
restart need) for high pressure. RESTART is vital in all those plants with high thermal load and low inertia, where even a
few minutes of energy loss (usually time needed for diesel generator start-up) would increase the water temperature in
excess of that possible for any other chiller to start without the RESTART system.
155RC GROUP SpA • General Catalogue • 155.EN.0504
CHAR
ACTE
RIST
ICSHousing with aluminium profile frame •
with galvanized steel sheet panels
externally coated with PVC film
Main components housed in a •
technical compartment separated
from the air flow
Shell and tube evaporator •
Free-cooling system •
Microprocessor control system •
Modulating condensing control •
coupled with flooding system
Pump-Down stop •
Star/delta compressors •
starting system
Oil cooling system •
Step-step cooling capacity control •
Door lock main switch •
Optimizer system •
LNO Kit for about a 6 dB(A) noise •
pressure level reduction
Pumping group with 1 or 2 pumps •
Water tank •
Partial heat reclaim •
Mechanical flow switch •
Spring antivibration holders •
RS232C-RS422-RS485 serial line •
UDT, SQL or ASME VIII Div.1 approvals •
OPTI
ONAL
MAXIMO.SCREW.A.STD “G”R407C • 249 ÷ 392 kW
The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.
QuickStartWhatever is needed for a correct operation is built-in.
Electrical and water connections only are needed at start-up for
a complete installation in full compliance with all the current
norms.
HIGH
LIGHT
S
MateIntegrated condensing control system for a stepless speed
modulation of condensers fans.
Version available with R134a refrigerant chargesee page 274
156 RC GROUP SpA • General Catalogue• 155.EN.0504
MAXIMO.SCREW.A.ELN “G” - MODELSizeCooling capacity (1) kWFree-Cooling capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgMean sound pressure level (3) dB(A)
MAXIMO.SCREW.A.ELN “G” - MODELSizeCooling capacity (1) kWFree-Cooling capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgMean sound pressure level (3) dB(A)
230.V1 280.V1G9 G9
261,4 300,2255,6 252,8
1 11 1
5900 59002070 20702470 24704175 425559 59
200.V2 240.V2 280.V2G8 G9 G9
208,3 271,9 295,7185,8 255,7 250
2 2 22 2 2
5170 5900 59001590 2070 20702155 2470 24702860 4220 424555 60 69
(1) Data referred to chilled water temperature at 15/10°C; outdoor air temperature at 35°C.(2) Data referred to inlet chilled water temperature at 15°C; outdoor air temperature at 2,5°C.(3) Mean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 400.3.50+N
Free-cooling liquid chillers with axial fansTE
CHNI
CAL D
ATA
IDEN
TIFIC
ATIO
N MAXIMO.SCREW.A.ELN “G”Air cooled packaged liquid chillers in extremely low noise version equipped with energy saving free-cooling
SCR system, screw compressors and axial fans. Casing type: “G”.
AntiRumbleHighest energy saving and lowest noise emission together in the same product.
MAXIMO SCREW ELN exploits the typical low vibration operation of screw compressors to obtain a high
performing product at noise reduction level.
The unit base frame is realised with ANTIRUMBLE system and is made of a multiple layer structure with high
noise absorption characteristics, thus allowing the keeping of a high noise efficiency even in cases where the
units are installed in a “raised” position through weight distribution bars and/or antivibration holders.
157RC GROUP SpA • General Catalogue • 155.EN.0504
CHAR
ACTE
RIST
ICSHousing with aluminium profile frame •
with galvanized steel sheet panels
externally coated with PVC film
Main components housed in a •
technical compartment separated
from the air flow
Shell and tube evaporator •
Free-cooling system •
Microprocessor control system •
Modulating condensing control •
coupled with flooding system
Pump-Down stop •
Star/delta compressors •
starting system
Oil cooling system •
Step-step cooling capacity control •
Door lock main switch •
Optimizer system •
Pumping group with 1 or 2 pumps •
Water tank •
Partial heat reclaim •
Mechanical flow switch •
Spring antivibration holders •
RS232C-RS422-RS485 serial line •
UDT, SQL or ASME VIII Div.1 approvals •
OPTI
ONAL
MAXIMO.SCREW.A.ELN “G”R407C • 261 ÷ 300 kW
The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.
Made2LastHousing designed to last in time and in bad weather: flexible
capillary piping to avoid problems deriving from copper work
hardening; antivibration holders under the compressors to
reduce vibration transmission to the housing; electric cables
in conduit and metallic cableways; housing in anodized
aluminium; galvanized steel sheet parts; aluminium or stainless
steel small parts.
HIGH
LIGHT
S
FreezeProtectionEvaporator with built-in antifreeze
heater and high thickness insulation,
combined with proprietary software
for the automatic start up of the
pumping group with direct scanning
from the digital antifreeze sensor.
Version available with R134a refrigerant chargesee page 274
158 RC GROUP SpA • General Catalogue• 155.EN.0504
MAXIMO.SCREW.A.STD “U” - MODELSizeCooling capacity (1) kWFree-Cooling capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgMean sound pressure level (3) dB(A)
MAXIMO.SCREW.A.STD “U” - MODELSizeCooling capacity (1) kWFree-Cooling capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgMean sound pressure level (3) dB(A)
420.V1 470.V1 500.V1 550.V1U10 U10 U10 U11
472,9 520,9 543,4 622379 380,4 382,5 480,41 1 1 11 1 1 1
5500 5500 5500 64902385 2385 2385 23852430 2430 2430 24304880 4900 5000 580074 74 74 74
380.V2 460.V2 560.V2 660.V2 740.V2 840.V2 940.V2 1000.V2U10 U10 U11 U12 U12 U113 U14 U14
428,7 507,7 595 705,2 793,6 933,8 1043,7 1096,3373,2 379 477,4 557,6 566,3 665 760,9 765,8
2 2 2 2 2 2 2 22 2 2 2 2 2 2 2
5500 5500 6490 7480 7480 8470 9460 94602385 2385 2385 2385 2385 2385 2385 23852430 2430 2430 2430 2430 2430 2430 24304860 4980 6150 7250 7600 8600 9390 1085075 75 75 76 76 77 77 77
(1) Data referred to chilled water temperature at 15/10°C; outdoor air temperature at 35°C.(2) Data referred to inlet chilled water temperature at 15°C; outdoor air temperature at 2,5°C.(3) Mean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 400.3.50+N
Free-cooling liquid chillers with axial fansTE
CHNI
CAL D
ATA
IDEN
TIFIC
ATIO
N MAXIMO.SCREW.A.STD “U”Air cooled packaged liquid chillers equipped with energy saving free-cooling SCR system, screw compressors
and axial fans. Casing type: “U”.
ScrewMAXIMO SCREW represents the latest evolution in terms of energy saving granting the best energy
performances in all operating modes, Total Free-Cooling, Partial Free-Cooling and Mechanical Cooling.
SCREW compressors are helical twin high efficiency compressors granting the possibility of multistep or
proportional regulation. They are specifically designed to be used in air cooled chillers (high condensing
temperatures).
159RC GROUP SpA • General Catalogue • 155.EN.0504
CHAR
ACTE
RIST
ICSHousing with aluminium profile frame •
with galvanized steel sheet panels
externally coated with PVC film
Main components housed in a •
technical compartment separated
from the air flow
Shell and tube evaporator •
Free-cooling system •
Microprocessor control system •
Modulating condensing control •
coupled with flooding system
Pump-Down stop •
Star/delta compressors •
starting system
Oil cooling system •
Step-step cooling capacity control •
Door lock main switch •
Optimizer system •
LNO Kit for about a 6 dB(A) noise •
pressure level reduction
Pumping group with 1 or 2 pumps •
Water tank •
Partial heat reclaim •
Mechanical flow switch •
Spring antivibration holders •
RS232C-RS422-RS485 serial line •
UDT, SQL or ASME VIII Div.1 approvals •
OPTI
ONAL
MAXIMO.SCREW.A.STD “U”R407C • 472 ÷ 1096 kW
The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.
MyNoiseSolutions range (STD-LNO) conceived to
allow the selection directly from the
catalogue of the most suitable product
for the specific legislative or
environmental demands regarding the
noise emission control.
HIGH
LIGHT
S
Version available with R134a refrigerant chargesee page 274
Patent
Optimizer®Patented OPTIMIZER system for variable water flow or; thanks
to this solution it is possible to extend the application range to
temperate climate areas and/or to appreciably increase the
energy savings obtained through indirect free-cooling systems.
160 RC GROUP SpA • General Catalogue• 155.EN.0504
MAXIMO.SCREW.A.ELN “U” - MODELSizeCooling capacity (1) kWFree-Cooling capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgMean sound pressure level (3) dB(A)
MAXIMO.SCREW.A.ELN “U” - MODELSizeCooling capacity (1) kWFree-Cooling capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgMean sound pressure level (3) dB(A)
330.V1 370.V1 420.V1 470.V1 500.V1 550.V1U10 U10 U11 U11 U12 U12
366,4 400,9 477,2 515,7 651,5 628310,5 301,3 393 380,1 462,4 450,3
1 1 1 1 1 11 1 1 1 1 1
5500 5500 6490 6490 7480 74802385 2385 2385 2385 2385 23852430 2430 2430 2430 2430 24304830 4850 5400 5580 7050 709061 61 61 61 61 61
320.V2 380.V2 460.V2 560.V2 660.V2 740.V2U10 U10 U11 U12 U13 U14
360,5 407,1 502 601 705,5 802,1309,7 301,9 378,9 447,7 522 602,6
2 2 2 2 2 22 2 2 2 2 2
5500 5500 6490 7480 8470 94602385 2385 2385 2385 2385 23852430 2430 2430 2430 2430 24304840 4890 6000 7300 8100 885062 62 62 62 63 63
(1) Data referred to chilled water temperature at 15/10°C; outdoor air temperature at 35°C.(2) Data referred to inlet chilled water temperature at 15°C; outdoor air temperature at 2,5°C.(3) Mean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 400.3.50+N
Free-cooling liquid chillers with axial fansTE
CHNI
CAL D
ATA
MAXIMO.SCREW.A.ELN “U”Air cooled packaged liquid chillers in extremely low noise version equipped with energy saving free-cooling SCR
system, screw compressors and axial fans. Casing type: “U”.
ELN Range (Extremely low noise)RC Group experience in sound reduction techniques together with SCREW technology grant sound emission levels never achieved
in chillers with such reduced dimensions.
The result as for all ELN range chillers is achieved by a specific design philosophy concentrated on removing the sound emissions
at "source", without using "bolt-on" acoustic kits that can result in detrimental product efficiency, maintenance and durability.
Screw compressor characteristics reduce the requirement of "heavy weight" acoustic treatment so often required when
using reciprocating compressors.
Screw ELN range allows design compliance to meet specific legislative or environmental acoustic control measures
IDEN
TIFIC
ATIO
N
161RC GROUP SpA • General Catalogue • 155.EN.0504
CHAR
ACTE
RIST
ICSHousing with aluminium profile frame •
with galvanized steel sheet panels
externally coated with PVC film
Main components housed in a •
technical compartment separated
from the air flow
Shell and tube evaporator •
Free-cooling system •
Microprocessor control system •
Modulating condensing control •
coupled with flooding system
Pump-Down stop •
Star/delta compressors •
starting system
Oil cooling system •
Step-step cooling capacity control •
Door lock main switch •
Optimizer system •
LNO Kit for about a 6 dB(A) noise •
pressure level reduction
Pumping group with 1 or 2 pumps •
Water tank •
Partial heat reclaim •
Mechanical flow switch •
Spring antivibration holders •
RS232C-RS422-RS485 serial line •
UDT, SQL or ASME VIII Div.1 approvals •
OPTI
ONAL
MAXIMO.SCREW.A.ELN “U”R407C • 366 ÷ 802 kW
The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.
GlycolFreeThanks to a system of exchangers set inside the unit,
the free-cooling circuit is 100% protected from
freezing problems, while there is no antifreeze in the
building.
HIGH
LIGHT
S
RCProactiveMicroprocessor control and
monitoring system technology owned
by RC PROACTIVE, designed to grant
continuity of work even in emergency
situations.
Version available with R134a refrigerant chargesee page 274
162 RC GROUP SpA • General Catalogue• 155.EN.0504
MAXIMO.SCREW.A.STD “W” - MODELSizeCooling capacity (1) kWFree-Cooling capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgMean sound pressure level (3) dB(A)
1260.V3 1410.V3 1500.V3 1650.V3W21 W22 W23 W23
1399,3 1525,9 1671,9 1869,31088,6 1196 1333 1332,5
3 3 3 33 3 3 3
10800 11870 12940 129402350 2350 2350 23502610 2610 2610 2610
13830 15000 16100 1625084 84 84 84
(1) Data referred to chilled water temperature at 15/10°C; outdoor air temperature at 35°C.(2) Data referred to inlet chilled water temperature at 15°C; outdoor air temperature at 2,5°C.(3) Mean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 400.3.50+N
Free-cooling liquid chillers with axial fansTE
CHNI
CAL D
ATA
MAXIMO.SCREW.A.STD “W”Air cooled packaged liquid chillers equipped with energy saving free-cooling SCR system, screw compressors
and axial fans. Casing type: “W”.
IDEN
TIFIC
ATIO
N
RCProactiveMAXIMO W, a range of chillers equipped with SCR system and supplying up to 1.650 Kw for a single unit and with last
generation SCREW compressors. Also MAXIMO W is equipped with RESTART proprietary software.
In case of a restart after a possible stop of the units due to a blackout, this particular system activates a restart
procedure granting the chiller in operation even with a return water high temperature. Usually this situation would cause
an immediate stop of the chiller (complete stop with manual restart need) for high pressure. RESTART is vital in all those
plants with high thermal load and low inertia, where even a few minutes of energy loss (usually time needed for diesel
generator start-up) would increase the water temperature in excess of that possible for any other chiller to start without
the RESTART system.
163RC GROUP SpA • General Catalogue • 155.EN.0504
CHAR
ACTE
RIST
ICSHousing made of epoxy painted •
galvanized steel sheet
Shell and tube evaporator •
Free-cooling system •
Microprocessor control system •
Modulating condensing control •
coupled with flooding system
Pump-Down stop •
Star/delta compressors •
starting system
Oil cooling system •
Step-step cooling capacity control •
Door lock main switch •
LNO Kit for about a 6 dB(A) noise •
pressure level reduction
Partial heat reclaim •
Mechanical flow switch •
Spring antivibration holders •
RS232C-RS422-RS485 serial line •
UDT, SQL or ASME VIII Div.1 approvals •
OPTI
ONAL
MAXIMO.SCREW.A.STD “W”R407C • 1399 ÷ 1869 kW
The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.
CoolingDensityPlus1.650 kW in 30 m2 (DF = 55 kW/m2), the free-cooling chiller with
the highest Cooling Density (kW per m2 plant space) available today
on the market.
HIGH
LIGHT
S
ScrewTwin SCREW compressor are helical twin compressors with high
efficiency which grant the possibility of multistep or proportional
regulation and are specifically designed to be used in air cooled
chillers (high condensing temperatures).
Version available with R134a refrigerant chargesee page 274
164 RC GROUP SpA • General Catalogue• 155.EN.0504
MAXIMO.SCROLL.C.STD “G” - MODELSizeCooling capacity (1) kWFree-Cooling capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgMean sound pressure level (3) dB(A)
MAXIMO.SCROLL.C.STD “G” - MODELSizeCooling capacity (1) kWFree-Cooling capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgMean sound pressure level (3) dB(A)
21.Z1 25.Z1 32.Z1 37.Z1 50.Z1 61.Z1G1 G1 G1 G3 G3 G3
20,9 23,8 31,4 38,6 52,1 6217,7 19,5 22,6 35,4 45,8 45,8
1 1 1 1 1 11 1 1 1 1 1
1150 1150 1150 2000 2600 26001100 1100 1100 1250 1410 14101960 1960 1960 2010 2010 2010435 435 460 740 820 84059 59 66 60 68 68
36.Z2 42.Z2 50.Z2 64.Z2 74.Z2 87.Z2 100.Z2 124.Z2G3 G3 G3 G3 G5 G7 G7 G7
35,8 42,6 47 61,4 75,6 92,1 101,8 122,133,4 38,3 39,6 45,7 66,3 87,4 89,1 92
2 2 2 2 2 2 2 22 2 2 2 2 2 2 2
2000 2000 2000 2000 2600 3600 3600 36001250 1250 1250 1250 1410 1560 1560 15602010 2010 2010 2010 2010 2010 2010 2010760 780 790 880 1210 1630 1690 173059 60 64 68 70 69 69 69
(1) Data referred to chilled water temperature at 15/10°C; outdoor air temperature at 35°C.(2) Data referred to inlet chilled water temperature at 15°C; outdoor air temperature at 2,5°C.(3) Mean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 400.3.50+N
Free-cooling liquid chillers with centrifugal fansTE
CHNI
CAL D
ATA
IDEN
TIFIC
ATIO
N MAXIMO.SCROLL.C.STD “G”Air cooled packaged liquid chillers equipped with energy saving free-cooling SCR system, Scroll compressors
and centrifugal fans. Casing type: “G”.
CentriMAXIMO SCROLL represents the latest generation of free-cooling chillers with SCR systems bringing together the vast RC
experience and the SCROLL latest generation technology to grant a more rapid return of the investment.
CENTRI version whose condensing section is equipped with centrifugal fans, allows the use of MAXIMO chillers even for INDOOR
installations. Indeed CENTRI allows the static pressure supplied by the fans section to conform to the possible pressure drops
due to duct system of condensing air intake and/or expulsion.
165RC GROUP SpA • General Catalogue • 155.EN.0504
CHAR
ACTE
RIST
ICSHousing with aluminium profile frame •
with galvanized steel sheet panels
externally coated with PVC film
Main components housed in a •
technical compartment separated
from the air flow
Plate evaporator •
Free-cooling system •
Microprocessor control system •
Modulating condensing control •
coupled with flooding system
Pump-Down stop •
Differential pressure switch •
on water side
Door lock main switch •
Optimizer system •
LNO Kit for about a 6 dB(A) noise •
pressure level reduction
Pumping group with 1 or 2 pumps •
Water tank •
Partial heat reclaim •
Mechanical flow switch •
Spring antivibration holders •
RS232C-RS422-RS485 serial line •
UDT, SQL or ASME VIII Div.1 approvals •
OPTI
ONAL
MAXIMO.SCROLL.C.STD “G”R407C • 21 ÷ 122 kW
The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.
AdaptiveRangeMultiple versions, optional
and mountings for a various
range of applications in
continental or cold climate
areas, from 24h/day hi-tech.
applications to nonstop
industrial processes
cooling.
HIGH
LIGHT
S
ScrollMAXIMO.SCROLL range is equipped with last generation SCROLL
compressors to grant the highest efficiency and the lowest noise
emission.
Version available with R134a refrigerant chargesee page 274
166 RC GROUP SpA • General Catalogue• 155.EN.0504
MAXIMO.SCROLL.C.ELN “G” - MODELSizeCooling capacity (1) kWFree-Cooling capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgMean sound pressure level (3) dB(A)
MAXIMO.SCROLL.C.ELN “G” - MODELSizeCooling capacity (1) kWFree-Cooling capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgMean sound pressure level (3) dB(A)
21.Z1 25.Z1 32.Z1 37.Z1 50.Z1 61.Z1G3 G3 G3 G5 G5 G5
21,8 25 31,9 39,5 53 63,521,2 23,8 27,7 39,2 49,9 51,5
1 1 1 1 1 11 1 1 1 1 1
2000 2000 2000 2600 2600 26001250 1250 1250 1410 1410 14102010 2010 2010 2010 2010 2010660 660 690 980 1060 107048 50 53 52 60 60
36.Z2 42.Z2 50.Z2 64.Z2 74.Z2 87.Z2 100.Z2 124.Z2G5 G5 G5 G5 G7 G8 G8 G8
36,5 42,7 48,7 63 74,8 94,5 104,8 121,436,9 39,8 44,3 51,4 72 111,7 114,2 117,4
2 2 2 2 2 2 2 22 2 2 2 2 2 2 2
2600 2600 2600 2600 3600 5170 5170 51701410 1410 1410 1410 1560 1590 1590 15902010 2010 2010 2010 2010 2050 2050 20501020 1030 1040 1110 1450 2060 2120 219051 52 54 60 61 60 60 60
(1) Data referred to chilled water temperature at 15/10°C; outdoor air temperature at 35°C.(2) Data referred to inlet chilled water temperature at 15°C; outdoor air temperature at 2,5°C.(3) Mean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 400.3.50+N
Free-cooling liquid chillers with centrifugal fansTE
CHNI
CAL D
ATA
MAXIMO.SCROLL.C.ELN “G”Air cooled packaged liquid chillers in extremely low noise version equipped with energy saving free-cooling SCR
system, Scroll compressors and centrifugal fans. Casing type: “G”.
ELN Range (Extremely Low Noise)RC ELN technology applied to MAXIMO free-cooling chillers.
These top levels are the result as for all ELN range chillers of a specific design philosophy concentrated on removing the sound
emissions at "source", without using "bolt-on" acoustic kits.
The use of the latest generation SCROLL compressors highlights the ELN range of characteristics making plant selection of
critical acoustic systems easy.
IDEN
TIFIC
ATIO
N
167RC GROUP SpA • General Catalogue • 155.EN.0504
CHAR
ACTE
RIST
ICSHousing with aluminium profile frame •
with galvanized steel sheet panels
externally coated with PVC film
Main components housed in a •
technical compartment separated
from the air flow
Plate evaporator •
Free-cooling system •
Microprocessor control system •
Modulating condensing control •
coupled with flooding system
Pump-Down stop •
Differential pressure switch •
on water side
Door lock main switch •
Optimizer system •
Pumping group with 1 or 2 pumps •
Water tank •
Partial heat reclaim •
Mechanical flow switch •
Spring antivibration holders •
RS232C-RS422-RS485 serial line •
UDT, SQL or ASME VIII Div.1 approvals •
OPTI
ONAL
MAXIMO.SCROLL.C.ELN “G”R407C • 22 ÷ 121 kW
The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.
Made2LastHousing designed to last in time and in any weather conditions:
flexible capillary ducting to avoid problems deriving from copper
work hardening; antivibration holders under the compressors to
reduce vibration transmission to the housing; electric cables in
conduit and metallic cableways; housing in anodized aluminium;
galvanized steel sheet parts; aluminium or stainless steel small
parts.
HIGH
LIGHT
S
QuickStartWhatever is needed for a correct operation is built-in. Electrical
and water connections only are needed at start-up for a complete
installation in full compliance with all the current norms.
Version available with R134a refrigerant chargesee page 274
168 RC GROUP SpA • General Catalogue• 155.EN.0504
Free-cooling liquid chillers with centrifugal fansTE
CHNI
CAL D
ATA MAXIMO.RECIP.C.STD “G” - MODEL
SizeCooling capacity (1) kWFree-Cooling capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgMean sound pressure level (3) dB(A)
MAXIMO.RECIP.C.STD “G” - MODELSizeCooling capacity (1) kWFree-Cooling capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgMean sound pressure level (3) dB(A)
142.F2 188.F2 220.F2G7 G7 G8
139,3 178,9 210,393,9 102,9 163,6
2 2 22 2 2
3600 3600 51701560 1560 15902010 2010 20501990 2140 276071 71 74
260.F2 300.F2G8 G8
258,5 287,2179,2 187
2 22 2
5170 51701590 15902050 20503130 315576 77
(1) Data referred to chilled water temperature at 15/10°C; outdoor air temperature at 35°C.(2) Data referred to inlet chilled water temperature at 15°C; outdoor air temperature at 2,5°C.(3) Mean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 400.3.50+N
MAXIMO.RECIP.C.STD “G”Air cooled packaged liquid chillers equipped with energy saving free-cooling SCR system, reciprocating
compressors and centrifugal fans. Casing type: “G”.
CentriThanks to CENTRI it is now possible to take advantage from the energy savings granted by SCR free-cooling
system even in ducted or INDOOR applications.
CENTRI version allows the adaptation of MAXIMO air performances to plant needs, with regards to air intake
and/or expulsion duct system or to additional pressure drops due to grilles or insulation devices.
IDEN
TIFIC
ATIO
N
169RC GROUP SpA • General Catalogue • 155.EN.0504
CHAR
ACTE
RIST
ICSHousing with aluminium profile frame •
with galvanized steel sheet panels
externally coated with PVC film
Main components housed in a •
technical compartment separated
from the air flow
Shell and tube evaporator •
Free-cooling system •
Microprocessor control system •
Modulating condensing control •
coupled with flooding system
Pump-Down stop •
Step-step cooling capacity control •
Door lock main switch •
Optimizer system •
LNO Kit for about a 6 dB(A) noise •
pressure level reduction
Pumping group with 1 or 2 pumps •
Water tank •
Partial heat reclaim •
Part-Winding compressors •
starting system
Mechanical flow switch •
Spring antivibration holders •
RS232C-RS422-RS485 serial line •
UDT, SQL or ASME VIII Div.1 approvals •
OPTI
ONAL
MAXIMO.RECIP.C.STD “G”R407C • 140 ÷ 288 kW
The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.
CoolingDensityPlusOptimization of internal layout to achieve the best ratio
between footprint and cooling capacity.
PumpStationA complete built-in pumping station (without size increase),
equipped with instruments and safety devices totally integrated
with the unit control system in order to emphasize its working.
HIGH
LIGHT
S
Version available with R134a refrigerant chargesee page 274
170 RC GROUP SpA • General Catalogue• 155.EN.0504
Free-cooling liquid chillers with centrifugal fansTE
CHNI
CAL D
ATA MAXIMO.RECIP.C.ELN “G” - MODEL
SizeCooling capacity (1) kWFree-Cooling capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgMean sound pressure level (3) dB(A)
142.F2 188.F2 220.F2G8 G8 G8
138,5 176,2 213,7119,9 132,6 154,5
2 2 22 2 2
5170 5170 51701590 1590 15902050 2050 20502360 2500 270060 61 67
(1) Data referred to chilled water temperature at 15/10°C; outdoor air temperature at 35°C.(2) Data referred to inlet chilled water temperature at 15°C; outdoor air temperature at 2,5°C.(3) Mean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 400.3.50+N
MAXIMO.RECIP.C.ELN “G”Air cooled packaged liquid chillers in extremely low noise version equipped with energy saving free-cooling SCR
system, reciprocating compressors and centrifugal fans. Casing type: “G”.
IDEN
TIFIC
ATIO
N
RCProactiveHighest energy saving, lowest noise emission and possibility to INDOOR installation, all in the same product.
Thanks to MAXIMO ELN CENTRI version, it is possible to take advantage from SCR indirect energy saving system
even in those situations where it is necessary to install the chiller in arranged spaces or to apply additional
acoustic control systems (barriers) in order to achieve the prescribed acoustic parameters. Everything is
managed through PROACTIVE logic, typical of all RC microprocessor controls range.
171RC GROUP SpA • General Catalogue • 155.EN.0504
CHAR
ACTE
RIST
ICSHousing with aluminium profile frame •
with galvanized steel sheet panels
externally coated with PVC film
Main components housed in a •
technical compartment separated
from the air flow
Shell and tube evaporator •
Free-cooling system •
Microprocessor control system •
Modulating condensing control •
coupled with flooding system
Pump-Down stop •
Step-step cooling capacity control •
Door lock main switch •
Optimizer system •
LNO Kit for about a 6 dB(A) noise •
pressure level reduction
Pumping group with 1 or 2 pumps •
Water tank •
Partial heat reclaim •
Part-Winding compressors •
starting system
Mechanical flow switch •
Spring antivibration holders •
RS232C-RS422-RS485 serial line •
UDT, SQL or ASME VIII Div.1 approvals •
OPTI
ONAL
MAXIMO.RECIP.C.ELN “G”R407C • 138 ÷ 214 kW
The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.
Easy@ServeAll components are accessible through handy
frontal panels without removal of heavy noise
reduction boxes.HIGH
LIGHT
S
ZytelThe special compressor air supply pipelines made of patented plastic
material avoid the vibrations transmission from the compressor to
the condensing coils reducing the total noise emission and avoiding
the early materials decay.
Version available with R134a refrigerant chargesee page 274
172 RC GROUP SpA • General Catalogue• 155.EN.0504
RC GROUP liquid chillers: wide range of units in terms of models, compressors and refrigerants.
HEAT PUMPRC GROUP heat pump chillers are available with Scroll, reciprocating and Screw compressors and are characterised by a highenergy efficiency and by a total reliability even in coldest climates, thanks to the control logic of internationally patented IDEA
(Intelligent Defrosting system for Energy saving Applications) defrosting cycles.This dynamic parameters reading logic which is able to identify the real presence of ice on the evaporating coil, allows a 20% energysavings.Moreover, being an autoadaptive logic, it excludes the possibility of regulation parameters choice and can automatically adapt both toworking conditions and to climate.Units are available both with axial and centrifugal fans.
ELN RANGE (EXTREMELY LOW NOISE)For over 20 years RC Group has offered a standard catalogued range of units designed specifically to provide the "lowest noiseemission" equipment on the market.The design and continuous development of the ELN range has avoided using "bolt-on" acoustic kits, adding weight and reducing theserviceability of the equipment but instead has concentrated on removing the sound emissions at "source".By careful selection of matched components and innovative design of the condensing coil surface and airflow distribution, the ELN rangehas evolved into one of the quietest and thermally efficient Packaged Chillers in today's market place.This one solution grants : high efficiency, extremely low sound emissions and easy maintenance, no need to remove heavy noise reductionkits or acoustic barriers. The performance and durability of the RC Group solution lasts with time, unlike that of the materials of the"bolt-on" sound reduction kits that can decay over time.All RC Group chillers are available in the ELN range, including versions with axial or centrifugal fans.
PLAN
T TY
PEHeat pump air cooled liquid chillers
173RC GROUP SpA • General Catalogue• 155.EN.0504
Heat pump air cooledliquid chillers
EASY.A.P.STD “R” • R407C • 5 ÷ 41 kWHeat pump liquid chillers with scroll compressor.
EASY.A.P.STD “U” • R407C • 47 ÷ 175 kWHeat pump liquid chillers with scroll compressors.
EASY.A.P.STD “W” • R407C • 205 ÷ 450 kWHeat pump liquid chillers with scroll compressors.
CILLI.IDROCOMPL.A.P.STD.Z1 • R407C • 6 ÷ 16 kWIdrocompl heat pump liquid chillers with scroll compressors.
CILLI.IDROCOMPL.A.P.STD.Z2 • R407C • 20 ÷ 50 kWIdrocompl heat pump liquid chillers with scroll compressors.
REVERSO.SCROLL.A.P.STD “G” • R407C • 20 ÷ 112 kWHeat pump liquid chillers with scroll compressors.
REVERSO.SCROLL.A.P.ELN “G” • R407C • 19 ÷ 108 kWExtremely low noise heat pump liquid chillers with scroll compressors.
REVERSO.RECIP.A.P.STD “G” • R407C • 132 ÷ 392 kWHeat pump liquid chillers with reciprocating compressors.
REVERSO.RECIP.A.P.ELN “G” • R407C • 130 ÷ 267 kWExtremely low noise heat pump liquid chillers with reciprocating compr.
REVERSO.RECIP.A.P.STD “U” • R407C • 450 ÷ 980 kWHeat pump liquid chillers with reciprocating compressors.
REVERSO.RECIP.A.P.ELN “U” • R407C • 360 ÷ 780 kWExtremely low noise heat pump liquid chillers with reciprocating compr.
MODULO.RECIP.A.P.STD • R407C • 207 ÷ 480 kWModular heat pump liquid chillers with reciprocating compressor.
REVERSO.SCREW.A.P.STD “G” • R407C • 235 ÷ 376 kWHeat pump liquid chillers with screw compressors.
REVERSO.SCREW.A.P.ELN “G” • R407C • 237 ÷ 312 kWExtremely low noise heat pump liquid chillers with screw compressors.
REVERSO.SCREW.A.P.STD “U” • R407C • 440 ÷ 1117 kWHeat pump liquid chillers with screw compressors.
REVERSO.SCREW.A.P.ELN “U” • R407C • 341 ÷ 832 kWExtremely low noise heat pump liquid chillers with screw compressors.
CILLI.IDROCOMPL.C.P.STD.Z1 • R407C • 6 ÷ 16 kWIdrocompl heat pump liquid chillers with scroll compressor.
CILLI.IDROCOMPL.C.P.STD.Z2 • R407C • 21 ÷ 51 kWIdrocompl heat pump liquid chillers with scroll compressors.
REVERSO.SCROLL.C.P.STD “G” • R407C • 19 ÷ 110 kWHeat pump liquid chillers with scroll compressors.
REVERSO.SCROLL.C.P.ELN “G” • R407C • 18 ÷ 107 kWExtremely low noise heat pump liquid chillers with scroll compressors.
REVERSO.RECIP.C.P.STD “G” • R407C • 126 ÷ 260 kWHeat pump liquid chillers with reciprocating compressors.
REVERSO.RECIP.C.P.ELN “G” • R407C • 130 ÷ 200 kWExtremely low noise heat pump liquid chillers with reciprocating compr.
174 AXIAL FANS
176
178
180
182
184
186
188
190
192
194
196
198
200
202
204
206 CENTRIFUGAL FANS
208
210
212
214
216
INDE
X
174 RC GROUP SpA • General Catalogue• 155.EN.0504
EASY.A.P.STD “R” - MODELSizeCooling capacity (1) kWHeating capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgMean sound pressure level (3) dB(A)
EASY.A.P.STD “R” - MODELSizeCooling capacity (1) kWHeating capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgMean sound pressure level (3) dB(A)
M.5.Z1 M.6.Z1 M.8.Z1 M.9.Z1R1 R1 R1 R15,2 6,4 7,3 8,56,1 7,5 8,6 10,31 1 1 11 1 1 1
1048 1048 1048 1048460 460 460 460836 836 836 83680 80 82 8357 57 57 57
T.8.1 T.9.Z1 T.11.Z1 T.14.Z1 T.16.Z1 T.18.Z1 T.20.Z1 T.24.Z1 T.28.Z1 T.35.Z1 T.43.Z1R1 R1 R2 R2 R2 R2 R3 R3 R3 R4 R47,4 8,5 10,9 12,6 15,2 17 19,7 23,5 26,8 32,6 418,6 10,3 13,3 15,4 18,5 20,8 24 28,6 32 39,6 50,21 1 1 1 1 1 1 1 1 1 11 1 1 1 1 1 1 1 1 1 1
1048 1048 1305 1305 1305 1305 1305 1305 1305 1805 1805460 460 580 580 580 580 580 580 580 580 580836 836 900 900 900 900 1.285 1.285 1.285 1.285 1.28582 83 105 108 115 120 179 194 214 294 30957 57 57 57 60 60 59 59 62 62 62
(1) Data referred to chilled water temperature at 12/7°C; air to condenser at 35°C.(2) Data referred to inlet hot water temperature at 40°C; air to gas/air heat exchanger at 7°C with 90%RH.(3) Mean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 230.1.50 for “M” models • 400.3.50+N for “T” models
Heat pump liquid chillers with axial fansTE
CHNI
CAL D
ATA
IDEN
TIFIC
ATIO
N EASY.A.P.STD “R”Heat pump air cooled packaged liquid chillers equipped with Scroll compressor and axial fans.
ServiceFastHeat pump version of EASY range makes this product the ideal solution for air small/medium air conditioning
systems in all areas where winter temperatures are mild.
Moreover by equipping EASY.P with IDRONICPACK you obtain a “package” needing only hydraulic and electrical
connections to be fully operative and satisfy all year long heat and chill requests.
175RC GROUP SpA • General Catalogue• 155.EN.0504
CHAR
ACTE
RIST
ICSHousing in galvanized steel sheet •
externally coated with PVC film
Plate gas/water heat exchanger •
Microprocessor control system •
Cycle inversion valve •
Antifreeze system •
Water flow control •
Idronic group •
Modulating condensing control •
Remote control board •
RS485 serial line • OPTI
ONAL
EASY.A.P.STD “R”R407C • 5 ÷ 41 kW
The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.
HIGH
LIGHT
S
IdronicPackWater pump and tank in a
single package installed under
the chiller; a complete plant
without any increase in overall
dimensions.
Made2LastHousing designed to last in time
and in any weather condition
thanks to the use of CORROSION
PROOF materials and
technology.
QuickStartWhatever is needed for a
correct operation is built-in.
Electrical and water
connections only are needed
at start-up for a complete
installation in full compliance
with all the current norms.
176 RC GROUP SpA • General Catalogue• 155.EN.0504
(1) Data referred to chilled water temperature at 12/7°C; air to condenser at 35°C.(2) Data referred to inlet hot water temperature at 40°C; air to gas/air heat exchanger at 7°C with 90%RH.(3) Mean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 400.3.50+N
Heat pump liquid chillers with axial fansTE
CHNI
CAL D
ATA EASY.A.P.STD “U” - MODEL
SizeCooling capacity (1) kWHeating capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgMean sound pressure level (3) dB(A)
EASY.A.P.STD “U” - MODELSizeCooling capacity (1) kWHeating capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgMean sound pressure level (3) dB(A)
T.50.Z2 T.55.Z2 T.68.Z2 T.84.Z2U5 U5 U6 U6
47,1 54,8 67,1 83,157,9 66,5 80,3 101
2 2 2 21 1 1 1
2000 2000 2580 25801200 1200 1200 12001630 1630 1630 1630750 750 820 84561 61 62 62
T.100.Z2 T.125.Z2 T.150.Z3 T.188.Z3U7 U7 U8 U8
96,1 120,2 141,8 175,5119,7 146,8 177,8 216,9
2 2 3 31 1 1 1
3020 3020 4120 41201200 1200 1800 18001950 1950 1950 19501110 1130 1660 170067 71 69 72
IDEN
TIFIC
ATIO
N EASY.A.P.STD “U”Heat pump air cooled packaged liquid chillers equipped with Scroll compressors and axial fans.
PerformancePlusEASY P with PERFORMANCEPLUS system; up to three scroll type compressors in parallel connection to
grant the maximum energy efficiency in partial load operation, which represents more than 70% of the
yearlong working hours.
PERFORMANCEPLUS system emphasizes the energy saving characteristics granted by IDEA patented
software, proving EASY P heat pumps to be the most efficient solution currently available on the market
from the point of view of the electric consumption.
177RC GROUP SpA • General Catalogue• 155.EN.0504
CHAR
ACTE
RIST
ICSHousing in galvanized steel sheet •
externally coated with PVC film
Plate gas/water heat exchanger •
Microprocessor control system •
Antifreeze system •
Water flow control •
Modulating condensing control •
Cycle inversion valve •
Pump-Down stop •
IDEA defrosting system •
Door lock main switch •
Idronic group •
Remote control board •
RS485 serial line •
Partial heat reclaim •
Mechanical flow switch •
Spring antivibration holders •
Outdoor air temperature sensor •
UDT, SQL or ASME VIII Div.1 approvals •
OPTI
ONAL
EASY.A.P.STD “U”R407C • 47 ÷ 175 kW
The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.
HIGH
LIGHT
S
MPComThe new generation of RC
microprocessors with
AUTOADAPTIVE logic self-adapting in
real time to the effective working
conditions of the unit according to
precise parameters such as:
water flow, plant inertia, outdoor
air temperature and presence of
antifreeze solutions in the plant.
ServiceFastCompressors, electric board
and electronic control system
housed in a technical
compartment separated from
the air flow to allow standard
maintenance with the unit in
operation.
178 RC GROUP SpA • General Catalogue• 155.EN.0504
Made2LastHousing designed to last in time and in any weather condition: flexible capillary pipes to avoid problems deriving from
copper work hardening; antivibration holders under the compressors to reduce vibration transmission to the housing;
galvanized steel sheet parts; aluminium or stainless steel small parts.
(1) Data referred to chilled water temperature at 12/7°C; air to condenser at 35°C.(2) Data referred to inlet hot water temperature at 40°C; air to gas/air heat exchanger at 7°C with 90%RH.(3) Mean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 400.3.50+N
Heat pump liquid chillers with axial fansTE
CHNI
CAL D
ATA EASY.A.P.STD “U” - MODEL
SizeCooling capacity (1) kWHeating capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgMean sound pressure level (3) dB(A)
T.200.Z4 T.240.Z4 T.300.Z6 T.360.Z6 T.400.Z6 T..450.Z6W1 W1 W2 W2 W3 W3
205,1 242,1 309,3 366 400 445241,7 285,3 364 430,3 472 520
4 4 6 6 6 62 2 2 2 2 2
2606 2606 3756 3756 4840 48402320 2320 2320 2320 2320 23202490 2490 2490 2490 2490 24901960 2160 2880 3180 3260 336069 73 71 74 75 76
IDEN
TIFIC
ATIO
N
EASY.A.P.STD “W”Heat pump air cooled packaged liquid chillers equipped with Scroll compressors and axial fans.
179RC GROUP SpA • General Catalogue• 155.EN.0504
CHAR
ACTE
RIST
ICSHousing in epoxy painted •
galvanized steel sheet
Plate gas/water heat exchanger •
Microprocessor control system •
Antifreeze system •
Water flow control •
Modulating condensing control •
Cycle inversion valve •
Pump-Down stop •
IDEA defrosting system •
Door lock main switch •
Idronic group •
RS485 serial line •
Partial heat reclaim •
Mechanical flow switch •
Spring antivibration holders •
Outdoor air temperature sensor •
UDT, SQL or ASME VIII Div.1 approvals •
OPTI
ONAL
EASY.A.P.STD “W”R407C • 205 ÷ 450 kW
The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.
HIGH
LIGHT
S
ScrollThe state of the art technology in the field of medium/small size
compressors to grant excellent performances even in medium
and small dimensions plants.
Patent
Idea®“Patented” defrosting system with dynamic reading of working
parameters. Thanks to proprietary software it senses the real
presence of brine on the coil, it grants defrosting cycles limited to
the real working conditions and brings a remarkable energy saving
(more than 20-30% on the average) and a higher working continuity.
180 RC GROUP SpA • General Catalogue• 155.EN.0504
CILLI.IDROCOMPL.A.P.STD.Z1 - MODELCooling capacity (1) kWHeating capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgMean sound pressure level (3) dB(A)
CILLI.IDROCOMPL.A.P.STD.Z1 - MODELCooling capacity (1) kWHeating capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgMean sound pressure level (3) dB(A)
M.7.Z1 M.8.Z1 M.9.Z16,2 6,9 8,37,1 8,1 9,81 1 11 1 1
1242 1242 1242447 447 447844 844 844138 140 14850 50 50
T.8.Z1 T.9.Z1 T.13.Z1 T.16.Z1 T.19.Z16,9 8,3 12,7 14,5 15,78,1 9,8 14,6 17,1 17,81 1 1 1 11 1 1 1 1
1242 1242 1342 1342 1342447 447 497 497 497844 844 969 969 969140 148 189 199 20950 50 54 54 54
Heat pump liquid chillers with axial fansTE
CHNI
CAL D
ATA
(1) Data referred to chilled water temperature at 12/7°C; air to condenser at 35°C.(2) Data referred to inlet hot water temperature at 40°C; air to gas/air heat exchanger at 7°C with 90%RH.(3) Mean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 230.1.50 for “M” models • 400.3.50+N for “T” models
IDEN
TIFIC
ATIO
N CILLI.IDROCOMPL.A.P.STD.Z1Heat pump air cooled packaged liquid chillers equipped with Scroll compressor, axial fan and Idrocompl
system.
Patent
Idrocompl®The high reliability of IDROCOMPL system in heat pump version to meet all air conditioning requirements
12 months a year, in areas with temperate climate.
Easy installation together with NOFREEZE system totally protecting the evaporator from risks of water
freezing, make this product the ideal solution for small air conditioning systems.
181RC GROUP SpA • General Catalogue• 155.EN.0504
CHAR
ACTE
RIST
ICSHousing in galvanized steel sheet •
externally coated with PVC film
IDROCOMPL system •
Microprocessor control system •
Antifreeze system •
On/off condensing control •
Circulation pump •
Modulating condensing control •
Remote control board •
RS485 serial line • OPTI
ONAL
CILLI.IDROCOMPL.A.P.STD.Z1R407C • 6 ÷ 16 kW
The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.
HIGH
LIGHT
S
Pump&PressurePUMP&PRESSURE kit consists of a
built-in circulation pump and of a
water pressure control system.
Through this kit CILLI IDROCOMPL P
becomes a real “package” only
needing electrical and hydraulic
connections to be 100% operating
respecting all the current norms.
Made2LastHousing designed to last in time and in any
weather condition: flexible capillary pipes to
avoid problems deriving from copper work
hardening; antivibration holders under the
compressors to reduce vibration
transmission to the housing; galvanized
steel sheet parts; aluminium or stainless
steel small parts.
182 RC GROUP SpA • General Catalogue• 155.EN.0504
CILLI.IDROCOMPL.A.P.STD.Z2 - MODELCooling capacity (1) kWHeating capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgMean sound pressure level (3) dB(A)
CILLI.IDROCOMPL.A.P.STD.Z2 - MODELCooling capacity (1) kWHeating capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgMean sound pressure level (3) dB(A)
T.24.Z2 T.28.Z2 T.34.Z220,4 23,7 27,923,4 26,6 32,4
2 2 21 1 1
1300 1300 1300895 895 895
1645 1645 1645385 395 43561 61 61
T.38.Z2 T.42.Z2 T.50.Z2 T.58.Z231,2 37,2 43,5 49,836,1 42,1 48,7 56,9
2 2 2 21 1 1 1
2000 2000 2000 2000895 895 895 895
1645 1645 1645 1645495 635 665 67062 64 64 64
(1) Data referred to chilled water temperature at 12/7°C; air to condenser at 35°C.(2) Data referred to inlet hot water temperature at 40°C; air to gas/air heat exchanger at 7°C with 90%RH.(3) Mean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 400.3.50+N
Heat pump liquid chillers with axial fansTE
CHNI
CAL D
ATA
IDEN
TIFIC
ATIO
N CILLI.IDROCOMPL.A.P.STD.Z2Heat pump air cooled packaged liquid chillers equipped with Scroll compressors, axial fans and Idrocompl
system.
Patent
Idrocompl®Patented system including in a single device the evaporator, the water tank and the expansion tank.
183RC GROUP SpA • General Catalogue• 155.EN.0504
CHAR
ACTE
RIST
ICSHousing with aluminium profile frame •
with galvanized steel sheet panels
externally coated with PVC film
IDROCOMPL system •
Microprocessor control system •
Antifreeze system •
On/off condensing control •
Circulation pump •
Modulating condensing control •
Remote control board •
RS485 serial line •
Spring antivibration holders •
Door lock main switch •
OPTI
ONAL
CILLI.IDROCOMPL.A.P.STD.Z2R407C • 20 ÷ 50 kW
The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.
ServiceFastCompressors, electric board and
electronic control system housed in a
technical compartment separated from
the air flow to allow standard
maintenance with the unit in operation.
9
8
7
6
55
13
12
11
10
2 31 2 4
1. Water outlet2. Cooling circuits3. Magnesium anode4. Breather valve5. Temperature sensors6. Water pump (optional)7. Safety valve8. Water inlet9. Discharge tap10. Water tank11. Expansion tank12. Anticondensate insulation13. Gas/water heat exchanger
Idrocompl® System
HIGH
LIGHT
S
QuickStartWhatever is needed for a correct
operation is built-in.
Electrical and water connections only are
needed at start-up for a complete
installation in full compliance with all the
current norms.
184 RC GROUP SpA • General Catalogue• 155.EN.0504
REVERSO.SCROLL.A.P.STD “G” - MODELSizeCooling capacity (1) kWHeating capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgMean sound pressure level (3) dB(A)
REVERSO.SCROLL.A.P.STD “G” - MODELSizeCooling capacity (1) kWHeating capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgMean sound pressure level (3) dB(A)
21.Z1 25.Z1 32.Z1 37.Z1 50.Z1 61.Z1G0 G0 G2 G2 G2 G4
20,3 23,2 32,5 36,7 49,3 56,523,6 26,6 35,6 42,2 55,4 66,9
1 1 1 1 1 11 1 1 1 1 1
1150 1150 2000 2000 2000 2600895 895 1040 1040 1040 1200
1640 1640 1690 1690 1690 1690350 350 500 560 610 77062 62 62 64 64 64
36.Z2 42.Z2 50.Z2 64.Z2 74.Z2 87.Z2 100.Z2 124.Z2G2 G2 G2 G4 G4 G6 G6 G6
34,2 39,7 44,6 57 68,4 86,3 96,1 112,340,1 47,1 54,5 69,2 83,2 100,8 113 134,3
2 2 2 2 2 2 2 22 2 2 2 2 2 2 2
2000 2000 2000 2600 2600 3600 3600 36001040 1040 1040 1200 1200 1290 1290 12901690 1690 1690 1690 1690 1690 1690 1690600 620 640 850 890 1210 1270 127064 64 64 64 65 66 66 66
(1) Data referred to outlet chilled water temperature at 7°C; air to condenser at 35°C.(2) Data referred to hot water temperature at 40/45°C; air to gas/air heat exchanger at 7°C with 90%RH.(3) Mean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 400.3.50+N
Heat pump liquid chillers with axial fansTE
CHNI
CAL D
ATA
IDEN
TIFIC
ATIO
N REVERSO.SCROLL.A.P.STD “G”Heat pump air cooled packaged liquid chillers equipped with Scroll compressors and axial fans. Casing
type: “G”.
PerformancePlusPERFORMANCEPLUS system emphasizes the energy saving characteristics granted by IDEA patented software, proving
REVERSO SCROLL heat pumps to be the most efficient solution currently available on the market from the point of view of the
electric consumption.
185RC GROUP SpA • General Catalogue• 155.EN.0504
CHAR
ACTE
RIST
ICSHousing with aluminium profile frame •
with galvanized steel sheet panels
externally coated with PVC film
Main components housed in a •
technical compartment separated
from the air flow
Plate gas/water heat exchanger •
Microprocessor control system •
Cycle inversion valve •
Step-step condensing control •
Pump-Down stop •
IDEA defrosting system •
Differential pressure switch •
on water side
Door lock main switch •
LNO Kit for about a 6 dB(A) noise •
pressure level reduction
Modulating condensing control •
Pumping group with 1 or 2 pumps •
Water tank •
Partial heat reclaim •
Mechanical flow switch •
Spring antivibration holders •
RS232C-RS422-RS485 serial line •
UDT, SQL or ASME VIII Div.1 approvals •
OPTI
ONAL
REVERSO.SCROLL.A.P.STD “G”R407C • 20 ÷ 112 kW
The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.
MyNoiseSolutions range (STD-LNO) conceived to allow the selection
directly from the catalogue of the most suitable product for the
specific legislative or environmental demands regarding the noise
emission control.
HIGH
LIGHT
S
Patent
IDEA®“Patented” defrosting system with
dynamic reading of working parameters.
Thanks to proprietary software it senses
the real presence of brine on the coil, it
grants defrosting cycles limited to the
real working conditions and brings a
remarkable energy saving (more than
20-30% on the average) and a higher
working continuity.
186 RC GROUP SpA • General Catalogue• 155.EN.0504
REVERSO.SCROLL.A.P.ELN “G” - MODELSizeCooling capacity (1) kWHeating capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgMean sound pressure level (3) dB(A)
REVERSO.SCROLL.A.P.ELN “G” - MODELSizeCooling capacity (1) kWHeating capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgMean sound pressure level (3) dB(A)
21.Z1 25.Z1 32.Z1 37.Z1 50.Z1 61.Z1G2 G2 G2 G4 G4 G4
18,8 21,6 29 34,4 45,2 54,323,5 27 35 41,5 54,3 66,9
1 1 1 1 1 11 1 1 1 1 1
2000 2000 2000 2600 2600 26001040 1040 1040 1200 1200 12001690 1690 1690 1690 1690 1690480 480 520 700 790 81050 53 51 53 54 55
36.Z2 42.Z2 50.Z2 64.Z2 74.Z2 87.Z2 100.Z2 124.Z2G4 G4 G4 G4 G6 G7 G7 G7
32,3 37,7 43,7 54,6 62,8 79,8 87,6 107,839,5 46,7 53,9 69,2 80,9 96,3 107,3 133,9
2 2 2 2 2 2 2 22 2 2 2 2 2 2 2
2600 2600 2600 2600 3600 3600 3600 36001200 1200 1200 1200 1290 1290 1290 12901690 1690 1690 1690 1690 2215 2215 2215750 780 780 850 1150 1260 1320 137053 51 55 55 53 56 56 57
(1) Data referred to outlet chilled water temperature at 7°C; air to condenser at 35°C.(2) Data referred to hot water temperature at 40/45°C; air to gas/air heat exchanger at 7°C with 90%RH.(3) Mean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 400.3.50+N
Heat pump liquid chillers with axial fansTE
CHNI
CAL D
ATA
REVERSO.SCROLL.A.P.ELN “G”Heat pump air cooled packaged liquid chillers in extremely low noise version equipped with Scroll
compressors and axial fans. Casing type: “G”.
IDEN
TIFIC
ATIO
N
ELN Range (Extremely low noise)RC ELN design technology applied to heat pumps.
Thanks to a specific design philosophy concentrated on removing the sound emissions at "source", REVERSO ELN range
requires no additional hardware that can result in detrimental product efficiency, maintenance and durability.
In this way the product achieves easy selection, installation and maintenance, granting cooling and acoustic performan-
ce and durability in time.
187RC GROUP SpA • General Catalogue• 155.EN.0504
CHAR
ACTE
RIST
ICSHousing with aluminium profile frame •
with galvanized steel sheet panels
externally coated with PVC film
Main components housed in a •
technical compartment separated
from the air flow
Plate gas/water heat exchanger •
Microprocessor control system •
Cycle inversion valve •
Step-step condensing control •
Pump-Down stop •
IDEA defrosting system •
Differential pressure switch •
on water side
Door lock main switch •
Modulating condensing control •
Pumping group with 1 or 2 pumps •
Water tank •
Partial heat reclaim •
Mechanical flow switch •
Spring antivibration holders •
RS232C-RS422-RS485 serial line •
UDT, SQL or ASME VIII Div.1 approvals •
OPTI
ONAL
REVERSO.SCROLL.A.P.ELN “G”R407C • 19 ÷ 108 kW
The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.
AdaptiveRangeA great variety of versions, models, optional and mountings to
satisfy a wide applications spectrum in air conditioning plants
for comfort, or advanced services in areas with mild climate.
HIGH
LIGHT
S
PumpStationA complete built-in pumping
station (without size
increase), equipped with
instruments and safety
devices totally integrated
with the unit control system
in order to emphasize its
working.
RCProactivePossibility to integrate PumpStation with water tank without
any unit dimensions increase.
188 RC GROUP SpA • General Catalogue• 155.EN.0504
REVERSO.RECIP.A.P.STD “G” - MODELSizeCooling capacity (1) kWHeating capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgMean sound pressure level (3) dB(A)
REVERSO.RECIP.A.P.STD “G” - MODELSizeCooling capacity (1) kWHeating capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgMean sound pressure level (3) dB(A)
142.F2 188.F2 220.F2 260.F2 300.F2G7 G7 G8 G8 G8
132,3 169,4 201,4 239,2 264,9150,8 188,9 222,5 265,3 298,6
2 2 2 2 22 2 2 2 2
3600 3600 5170 5170 51701290 1290 1290 1290 12902115 2115 2155 2215 22151665 1790 2240 2490 254066 66 67 73 73
320.S2 350.F2 385.S2 440.S2G9 G9 G9 G9
308,8 332,7 352,9 392333,3 389,6 388,4 429,8
2 2 2 22 2 2 2
5900 5900 5900 59001540 1540 1540 15402470 2470 2470 24704105 3397 4199 420974 74 74 74
(1) Data referred to outlet chilled water temperature at 7°C; air to condenser at 35°C.(2) Data referred to hot water temperature at 40/45°C; air to gas/air heat exchanger at 7°C with 90%RH.(3) Mean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 400.3.50+N
Heat pump liquid chillers with axial fansTE
CHNI
CAL D
ATA
IDEN
TIFIC
ATIO
N REVERSO.RECIP.A.P.STD “G”Heat pump air cooled packaged liquid chillers equipped with reciprocating compressors and axial fans.
Casing type: “G”.
Made2LastMedium capacity heat pump liquid chillers designed and built using MADE2LAST technology: flexible capillary pipes
to avoid problems deriving from copper work hardening; antivibration holders under the compressors to reduce
vibration transmission to the housing; housing in anodized aluminium; galvanized steel sheet parts; aluminium or
stainless steel small parts.
A housing designed to last in time and in any weather condition.
189RC GROUP SpA • General Catalogue• 155.EN.0504
CHAR
ACTE
RIST
ICSHousing with aluminium profile frame •
with galvanized steel sheet panels
externally coated with PVC film
Main components housed in a •
technical compartment separated
from the air flow
Shell and tube gas/water heat exchanger •
Microprocessor control system •
Step-step condensing control •
Pump-Down stop •
Part-Winding compressors •
starting system (S)
Step-step cooling capacity control •
Door lock main switch •
LNO Kit for about a 6 dB(A) noise •
pressure level reduction
Modulating condensing control •
Pumping group with 1 or 2 pumps •
Water tank •
Partial or total heat reclaim •
Part-Winding compressors •
starting system (F)
Mechanical or electronic flow switch •
Spring antivibration holders •
RS232C-RS422-RS485 serial line •
UDT, SQL or ASME VIII Div.1 approvals •
OPTI
ONAL
REVERSO.RECIP.A.P.STD “G”R407C • 132 ÷ 392 kW
The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.
BufferTankWater tank to increase plant
inertia with an important
reduction of compressors
start and stop for more
reliability and operating life.
HIGH
LIGHT
S
ServiceFastCompressors, electric board
and electronic control system
housed in a technical
compartment separated from
the air flow to allow standard
maintenance with the unit in
operation.
190 RC GROUP SpA • General Catalogue• 155.EN.0504
REVERSO.RECIP.A.P.ELN “G” - MODELSizeCooling capacity (1) kWHeating capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgMean sound pressure level (3) dB(A)
REVERSO.RECIP.A.P.ELN “G” - MODELSizeCooling capacity (1) kWHeating capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgMean sound pressure level (3) dB(A)
142.F2 188.F2 220.F2G8 G8 G8
129,1 163,7 187,7147,7 183,8 210,1
2 2 22 2 2
5170 5170 51701290 1290 12902155 2155 21551940 2045 222054 54 57
260.F2 300.F2G9 G9
236,1 267,3267,4 307
2 22 2
5900 59001540 15402470 24702790 291060 63
Heat pump liquid chillers with axial fansTE
CHNI
CAL D
ATA
(1) Data referred to outlet chilled water temperature at 7°C; air to condenser at 35°C.(2) Data referred to hot water temperature at 40/45°C; air to gas/air heat exchanger at 7°C with 90%RH.(3) Mean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 400.3.50+N
REVERSO.RECIP.A.P.ELN “G”Heat pump air cooled packaged liquid chillers in extremely low noise version equipped with reciprocating
compressors and axial fans. Casing type: “G”.
IDEN
TIFIC
ATIO
N
ELN Range (Extremely Low Noise)The redesign of the range to achieve excellence noise level typical of ELN logic, keeps REVERSO product
among the highest category levels for easy installation and maintenance characteristics, even when it is
proposed in EXTREMELY LOW NOISE version.
All operations control is remitted to MP99 microprocessor system, equipped with RC PROACTIVE
proprietary software, to grant continuity of work even in emergency situations.
191RC GROUP SpA • General Catalogue• 155.EN.0504
CHAR
ACTE
RIST
ICSHousing with aluminium profile frame •
with galvanized steel sheet panels
externally coated with PVC film
Main components housed in a •
technical compartment separated
from the air flow
Shell and tube gas/water heat exchanger •
Microprocessor control system •
Modulating condensing control •
Pump-Down stop •
Step-step cooling capacity control •
Door lock main switch •
Pumping group with 1 or 2 pumps •
Water tank •
Partial or total heat reclaim •
Part-Winding compressors •
starting system
Mechanical or electronic flow switch •
Spring antivibration holders •
RS232C-RS422-RS485 serial line •
UDT, SQL or ASME VIII Div.1 approvals •
OPTI
ONAL
REVERSO.RECIP.A.P.ELN “G”R407C • 130 ÷ 267 kW
The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.
SleepWellProprietary software for
lowest noise emission working
during the night.
HIGH
LIGHT
S
AntirumbleRigid base frame made of a multiple
layer structure with high noise
absorption characteristics, to reduce
the noise emission from the bottom of
the unit.
It is an essential component for all
those installations where the units are
installed “raised” from the floor
through weight distribution bars and/
or antivibration holders.
192 RC GROUP SpA • General Catalogue• 155.EN.0504
REVERSO.RECIP.A.P.STD “U” - MODELSizeCooling capacity (1) kWHeating capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgMean sound pressure level (3) dB(A)
REVERSO.RECIP.A.P.STD “U” - MODELSizeCooling capacity (1) kWHeating capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgMean sound pressure level (3) dB(A)
495.S2 550.S2 600.S2 660.S2U10 U10 U11 U11
456,2 491,5 553,2 588501,9 542,1 612 650,2
2 2 2 22 2 2 2
5500 5500 6490 64902130 2130 2130 21302430 2430 2430 24305114 5119 5700 570076 76 76 76
770.S2 880.S2 990.S2 1100.S2U13 U13 U14 U14
714,9 795,5 901 976,6794 882,6 995,6 1075,72 2 2 22 2 2 2
8470 8470 9460 94602130 2130 2130 21302430 2430 2430 24307051 7216 7892 789778 78 78 78
Heat pump liquid chillers with axial fansTE
CHNI
CAL D
ATA
(1) Data referred to outlet chilled water temperature at 7°C; air to condenser at 35°C.(2) Data referred to hot water temperature at 40/45°C; air to gas/air heat exchanger at 7°C with 90%RH.(3) Mean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 400.3.50+N
IDEN
TIFIC
ATIO
N REVERSO.RECIP.A.P.STD “U”Heat pump air cooled packaged liquid chillers equipped with reciprocating compressors and axial fans.
Casing type: “U”.
REVERSO “U” range includes heat pump liquid chillers up to 1.000 kW capacity, among the biggest available on the market
today. This allows to considerably reduce spaces and hydraulic and electrical connections in large air conditioning
systems.
This solution grants high installation and management savings. Moreover, the reduced number of compressors/fans used to
achieve these capacities decreases the risk rate usually considered as directly proportional to the number of moving
parts. RC is among the world leaders in this specific field, with hundred of installations realised with REVERSO liquid
chillers of capacity between 750 and 1.000 kW, indeed an experience hardly comparable.
193RC GROUP SpA • General Catalogue• 155.EN.0504
CHAR
ACTE
RIST
ICSHousing with aluminium profile frame •
with galvanized steel sheet panels
externally coated with PVC film
Main components housed in a •
technical compartment separated
from the air flow
Shell and tube gas/water heat exchanger •
Microprocessor control system •
Step-step condensing control •
Pump-Down stop •
Part-Winding compressors •
starting system
Step-step cooling capacity control •
Door lock main switch •
LNO Kit for about a 6 dB(A) noise •
pressure level reduction
Modulating condensing control •
Pumping group with 1 or 2 pumps •
Water tank •
Partial or total heat reclaim •
Mechanical or electronic flow switch •
Spring antivibration holders •
RS232C-RS422-RS485 serial line •
UDT, SQL or ASME VIII Div.1 approvals •
OPTI
ONAL
REVERSO.RECIP.A.P.STD “U”R407C • 450 ÷ 980 kW
The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.
CoolingDensityPlus1.000 kW cooling/heating capacity “package” in 20 m2 only.HI
GHLIG
HTS
PumpStationMoreover, adding PUMPSTATION, a real built-in pumping station, the
heat station turns to be immediately operative simply by making all
the electrical and hydraulic connections.
194 RC GROUP SpA • General Catalogue• 155.EN.0504
REVERSO.RECIP.A.P.ELN “U” - MODELSizeCooling capacity (1) kWHeating capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgMean sound pressure level (3) dB(A)
REVERSO.RECIP.A.P.ELN “U” - MODELSizeCooling capacity (1) kWHeating capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgMean sound pressure level (3) dB(A)
320.S2 350.F2 385.S2 440.S2 495.S2U10 U10 U11 U11 U12314 341,1 364,9 407,7 465,7
347,2 406,2 403,7 448,8 512,72 2 2 2 22 2 2 2 2
5500 5500 6490 6490 74802130 2130 2130 2130 21302430 2430 2430 2430 24304790 4082 4750 5360 547063 63 63 63 63
550.S2 600.S2 660.S2 770.S2 880.S2U12 U13 U13 U14 U14
503,8 558,3 594,6 703,8 780,1554,8 615,9 654,4 791,9 878,9
2 2 2 2 22 2 2 2 2
7480 8470 8470 9460 94602130 2130 2130 2130 21302430 2430 2430 2430 24305680 5870 5870 6850 731063 64 64 64 64
Heat pump liquid chillers with axial fansTE
CHNI
CAL D
ATA
(1) Data referred to outlet chilled water temperature at 7°C; air to condenser at 35°C.(2) Data referred to hot water temperature at 40/45°C; air to gas/air heat exchanger at 7°C with 90%RH.(3) Mean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 400.3.50+N
IDEN
TIFIC
ATIO
N REVERSO.RECIP.A.P.ELN “U”Heat pump air cooled packaged liquid chillers in extremely low noise version equipped with reciprocating
compressors and axial fans. Casing type: “U”.
ELN Range (Extremely Low Noise)For over 20 years RC Group has offered a complete range of units designed specifically to provide the "lowest noise emission"
equipment on the market.
The design and continuous development of the ELN range has avoided using "bolt-on" acoustic kits, adding weight and reducing
the serviceability of the equipment but instead has concentrated on removing the sound emissions at "source".
This one solution grants : high efficiency, extremely low sound emissions and easy maintenance, no need to remove heavy
noise reduction kits or acoustic barriers. The performance and durability of the RC Group solution lasts with time, unlike
that of the materials of the "bolt-on" sound reduction kits that can decay over time.
195RC GROUP SpA • General Catalogue• 155.EN.0504
CHAR
ACTE
RIST
ICSHousing with aluminium profile frame •
with galvanized steel sheet panels
externally coated with PVC film
Main components housed in a •
technical compartment separated
from the air flow
Shell and tube gas/water heat exchanger •
Microprocessor control system •
Modulating condensing control •
Pump-Down stop •
Part-Winding compressors •
starting system
Step-step cooling capacity control •
Door lock main switch •
Pumping group with 1 or 2 pumps •
Water tank •
Partial or total heat reclaim •
Mechanical or electronic flow switch •
Spring antivibration holders •
RS232C-RS422-RS485 serial line •
UDT, SQL or ASME VIII Div.1 approvals •
OPTI
ONAL
REVERSO.RECIP.A.P.ELN “U”R407C • 360 ÷ 780 kW
The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.
HIGH
LIGHT
S
Easy@ServeAll components are accessible through handy hinged panels
equipped with antiwind lock, without removal of heavy noise
deading boxes.
Patent
Idea®“Patented” defrosting system with dynamic reading of
working parameters. Thanks to proprietary software it
senses the real presence of brine on the coil, it grants
defrosting cycles limited to the real working conditions and
brings a remarkable energy saving (more than 20-30% on the
average) and a higher working continuity.
196 RC GROUP SpA • General Catalogue• 155.EN.0504
MODULO.RECIP.A.P.STD - MODELCooling capacity (1) kWHeating capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgMean sound pressure level (3) dB(A)
MODULO.RECIP.A.P.STD - MODELCooling capacity (1) kWHeating capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgMean sound pressure level (3) dB(A)
220.S1 330.S1207,1 293,1220,5 329,3
1 11 1
2830 28302300 23002395 23952970 325077 78
440.S1 550.S1392 477,3
431,1 529,21 11 1
2830 28302300 23002395 23953400 357080 80
Heat pump liquid chillers with axial fansTE
CHNI
CAL D
ATA
(1) Data referred to outlet chilled water temperature at 7°C; air to condenser at 35°C.(2) Data referred to hot water temperature at 40/45°C; air to gas/air heat exchanger at 7°C with 90%RH.(3) Mean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 400.3.50+N
MODULO.RECIP.A.P.STDHeat pump air cooled packaged liquid chillers equipped with reciprocating compressor and axial
fans.
IDEN
TIFIC
ATIO
N
CoolingDensityPlusAll RC Group experience in large capacity Heat Pump concentrated in an extremely small space thanks to COOLING DENSITY
PLUS system.
480 kW of cooling capacity and 530 kW of heating in only 6,5 m2 grant MODULO the record as a heat pump liquid chiller with
the highest Cooling Density (kW per m2 plant space) available on the market today (CD = 82 kW/m2).
197RC GROUP SpA • General Catalogue• 155.EN.0504
CHAR
ACTE
RIST
ICSHousing made of epoxy painted •
galvanized steel sheet
Shell and tube gas/water heat exchanger •
Microprocessor control system •
Step-step condensing control •
Pump-Down stop •
Part-Winding compressors •
starting system
Step-step cooling capacity control •
Door lock main switch •
LNO Kit for about a 6 dB(A) noise •
pressure level reduction
Modulating condensing control •
Pumping group with 1 or 2 pumps •
Mechanical or electronic flow switch •
Spring antivibration holders •
RS232C-RS422-RS485 serial line •
UDT, SQL or ASME VIII Div.1 approvals •
OPTI
ONAL
MODULO.RECIP.A.P.STDR407C • 207 ÷ 480 kW
The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.
SideBySideMODULO is designed to be installed side by side to obtain
very high cooling capacities in reduced areas (for instance
2 MW in only 26 m2!).HIGH
LIGHT
S
PumpStationA complete built-in pumping station (without size increase), equipped
with instruments and safety devices totally integrated with the unit
control system in order to emphasize RC PROACTIVE working.
4in40Thanks to 4in40 size system, four
MODULO chillers can be loaded into
a container, thus severely
reducing transport costs.
198 RC GROUP SpA • General Catalogue• 155.EN.0504
REVERSO.SCREW.A.P.STD “G” - MODELSizeCooling capacity (1) kWHeating capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgMean sound pressure level (3) dB(A)
REVERSO.SCREW.A.P.STD “G” - MODELSizeCooling capacity (1) kWHeating capacity (2) kWCompressors n.Gas circuits n.Dimension Length mm
Depth mmHeight mm
Net weight kgMean sound pressure level (3) dB(A)
230.V1 280.V1 330.V1 370.V1G8 G9 G9 G9
235 272,6 332 371,6289,8 335,6 395,3 450,8
1 1 1 11 1 1 1
5170 5900 5900 59001290 1540 1540 15402155 2470 2470 24702485 3255 3375 340071 72 72 72
200.V2 240.V2 280.V2 320.V2 380.V2G8 G8 G9 G9 G9
204,5 242,9 272,3 326,9 376,8254,1 314,6 340,2 394,3 463,1
2 2 2 2 22 2 2 2 2
5170 5170 5900 5900 59001290 1290 1540 1540 15402155 2155 2470 2470 24702425 2530 3300 3665 375972 72 73 73 73
(1) Data referred to outlet chilled water temperature at 7°C; air to condenser at 35°C.(2) Data referred to hot water temperature at 40/45°C; air to gas/air heat exchanger at 7°C with 90%RH.(3) Mean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 400.3.50+N
Heat pump liquid chillers with axial fansTE
CHNI
CAL D
ATA
IDEN
TIFIC
ATIO
N REVERSO.SCREW.A.P.STD “G”Heat pump air cooled packaged liquid chillers equipped with screw compressors and axial fans.
Casing type: “G”.
Patent
IDEA®Medium capacity heat pump liquid chillers equipped with last generation screw compressors to emphasize high efficiency
characteristics granted by patented defrosting system IDEA.
IDEA is the first system with dynamic reading of working parameters directly included in the built-in management system of
the unit. Thanks to the proprietary software, it senses the real presence of brine on the coil, grants defrosting cycles
limited to the real working conditions and brings a remarkable energy saving (more than 20-30% on the average) and a
higher working continuity.
199RC GROUP SpA • General Catalogue• 155.EN.0504
CHAR
ACTE
RIST
ICSHousing with aluminium profile frame •
with galvanized steel sheet panels
externally coated with PVC film
Main components housed in a •
technical compartment separated
from the air flow
Shell and tube gas/water heat exchanger •
Microprocessor control system •
Step-step condensing control •
Pump-Down stop •
Step-step cooling capacity control •
Oil cooling system •
Star/delta compressors starting system •
Door lock main switch •
LNO Kit for about a 6 dB(A) noise •
pressure level reduction
Modulating condensing control •
Pumping group with 1 or 2 pumps •
Water tank •
Partial heat reclaim •
Mechanical or electronic flow switch •
Spring antivibration holders •
RS232C-RS422-RS485 serial line •
UDT, SQL or ASME VIII Div.1 approvals •
OPTI
ONAL
REVERSO.SCREW.A.P.STD “G”R407C • 235 ÷ 376 kW
The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.
MyNoiseSolutions range (STD-LNO) conceived to allow the selection
directly from the catalogue of the most suitable product for the
specific legislative or environmental demands regarding the
noise emission control.
HIGH
LIGHT
S
AntirumbleRigid base frame made of a multiple layer structure with high noise
absorption characteristics, to reduce the noise emission from the
bottom of the unit. It is an essential component for all those installations
where the units are installed “raised” from the floor through weight
distribution bars and/or antivibration holders.
200 RC GROUP SpA • General Catalogue• 155.EN.0504
REVERSO.SCREW.A.P.ELN “G” - MODELSizeCooling capacity (1) kWHeating capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgMean sound pressure level (3) dB(A)
REVERSO.SCREW.A.P.ELN “G” - MODELSizeCooling capacity (1) kWHeating capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgMean sound pressure level (3) dB(A)
230.V1 280.V1G9 G9
237,8 279289,5 339,2
1 11 1
5900 59001540 15402470 24703075 315560 60
200.V2 240.V2 280.V2 320.V2G8 G9 G9 G9
200,1 246,9 278,6 312,7258,5 314,2 343,6 398,5
2 2 2 22 2 2 2
5170 5900 5900 59001290 1540 1540 15402155 2470 2470 24702425 3280 3300 366556 61 61 61
(1) Data referred to outlet chilled water temperature at 7°C; air to condenser at 35°C.(2) Data referred to hot water temperature at 40/45°C; air to gas/air heat exchanger at 7°C with 90%RH.(3) Mean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 400.3.50+N
Heat pump liquid chillers with axial fansTE
CHNI
CAL D
ATA
IDEN
TIFIC
ATIO
N REVERSO.SCREW.A.P.ELN “G”Heat pump air cooled packaged liquid chillers in extremely low noise version equipped with screw
compressors and axial fans. Casing type: “G”.
ELN Range (Extremely Low Noise)The particular noise emissions characterising screw compressors emphasizes the results obtained thanks to the redesign in ELN
version of the range, achieving excellent noise levels hardly to be found in the market.
At any rate REVERSO preserves the easiest installation and maintenance levels of its category.
SLEEPWELL proprietary system highlights the unit lowest noise emission during the night hours.
201RC GROUP SpA • General Catalogue• 155.EN.0504
CHAR
ACTE
RIST
ICSHousing with aluminium profile frame •
with galvanized steel sheet panels
externally coated with PVC film
Main components housed in a •
technical compartment separated
from the air flow
Shell and tube gas/water heat exchanger •
Microprocessor control system •
Modulating condensing control •
Pump-Down stop •
Step-step cooling capacity control •
Oil cooling system •
Star/delta compressors starting system •
Door lock main switch •
Pumping group with 1 or 2 pumps •
Water tank •
Partial heat reclaim •
Mechanical or electronic flow switch •
Spring antivibration holders •
RS232C-RS422-RS485 serial line •
UDT, SQL or ASME VIII Div.1 approvals •
OPTI
ONAL
REVERSO.SCREW.A.P.ELN “G”R407C • 237 ÷ 312 kW
The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.
Easy@ServeAll components are accessible through frontal panels,
without removal of heavy noise deading boxes.HIGH
LIGHT
S
RCProactiveAll operations control is carried out by MP99 microprocessor
system, equipped with RC PROACTIVE proprietary logic to grant
continuity of work even in emergency situations.
202 RC GROUP SpA • General Catalogue• 155.EN.0504
REVERSO.SCREW.A.P.STD “U” - MODELSizeCooling capacity (1) kWHeating capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgMean sound pressure level (3) dB(A)
REVERSO.SCREW.A.P.STD “U” - MODELSizeCooling capacity (1) kWHeating capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgMean sound pressure level (3) dB(A)
420.V1 470.V1 500.V1 550.V1U10 U10 U10 U11
440,3 471,9 492,4 577,2508,2 546,3 572,3 672,4
1 1 1 11 1 1 1
5500 5500 5500 64902130 2130 2130 21302430 2430 2430 24304380 4400 4450 500075 75 75 75
460.V2 560.V2 660.V2 740.V2 840.V2 940.V2 1000.V2 1100.V2U10 U11 U11 U12 U13 U13 U14 U14
463,9 563,8 658,4 726,7 843,8 917,6 990,6 1117,2554,8 671,5 803,9 867,3 978,4 1095,6 1145,8 1335,6
2 2 2 2 2 2 2 22 2 2 2 2 2 2 2
5500 6490 6490 7480 8470 8470 9460 94602130 2130 2130 2130 2130 2130 2130 21302430 2430 2430 2430 2430 2430 2430 24304480 5400 5410 6200 7300 7330 8050 807076 76 76 77 78 78 79 79
(1) Data referred to outlet chilled water temperature at 7°C; air to condenser at 35°C.(2) Data referred to hot water temperature at 40/45°C; air to gas/air heat exchanger at 7°C with 90%RH.(3) Mean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 400.3.50+N
Heat pump liquid chillers with axial fansTE
CHNI
CAL D
ATA
IDEN
TIFIC
ATIO
N REVERSO.SCREW.A.P.STD “U”Heat pump air cooled packaged liquid chillers equipped with screw compressors and axial fans.
Casing type: “U”.
The use of large screw compressors allows us to propose a range of heat pump liquid chillers with capacity up to
1.100 kW, indeed amongst the largest available on the market today. Thanks to this solution it is possible to meet the
most strict needs in terms of occupied spaces and hydraulic and electrical connections in large air conditioning
systems.
The results are great installation and operational savings. Moreover the reduced number of compressors/fans used
to achieve these capacities decreases the risk probability usually considered as directly proportional to the number
of moving parts.
203RC GROUP SpA • General Catalogue• 155.EN.0504
CHAR
ACTE
RIST
ICSHousing with aluminium profile frame •
with galvanized steel sheet panels
externally coated with PVC film
Main components housed in a •
technical compartment separated
from the air flow
Shell and tube gas/water heat exchanger •
Microprocessor control system •
Step-step condensing control •
Pump-Down stop •
Step-step cooling capacity control •
Oil cooling system •
Star/delta compressors starting system •
Door lock main switch •
LNO Kit for about a 6 dB(A) noise •
pressure level reduction
Modulating condensing control •
Pumping group with 1 or 2 pumps •
Water tank •
Partial or total heat reclaim •
Mechanical or electronic flow switch •
Spring antivibration holders •
RS232C-RS422-RS485 serial line •
UDT, SQL or ASME VIII Div.1 approvals •
OPTI
ONAL
REVERSO.SCREW.A.P.STD “U”R407C • 440 ÷ 1117 kW
The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.
PumpStationThanks to PUMPSTATION, a
complete built-in pumping
station, the heat station turns
to be immediately operative
simply by making all the
electrical and hydraulic
connections.
HIGH
LIGHT
S
ScrewTwin SCREW high efficiency compressors granting the possibility of
multistep or proportional regulation. They are specifically designed
to be used in air cooled chillers (high condensing temperatures).
204 RC GROUP SpA • General Catalogue• 155.EN.0504
REVERSO.SCREW.A.P.ELN “U” - MODELSizeCooling capacity (1) kWHeating capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgMean sound pressure level (3) dB(A)
REVERSO.SCREW.A.P.ELN “U” - MODELSizeCooling capacity (1) kWHeating capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgMean sound pressure level (3) dB(A)
330.V1 370.V1 420.V1 470.V1 500.V1 550.V1U10 U10 U10 U11 U11 U12341 374,5 423,4 474,8 500,7 580,7410 450,5 512,2 558,7 588,3 6851 1 1 1 1 11 1 1 1 1 1
5500 5500 5500 6490 6490 74802130 2130 2130 2130 2130 21302430 2430 2430 2430 2430 24304000 4050 4400 4950 4990 550062 62 62 62 62 62
380.V2 460.V2 560.V2 660.V2 740.V2 840.V2U10 U11 U12 U12 U13 U14
379,8 476,2 561 647,2 726,1 832,5462,7 566,9 681,3 809,7 904,2 1003,7
2 2 2 2 2 22 2 2 2 2 2
5500 6490 7480 7480 8470 94602130 2130 2130 2130 2130 21302430 2430 2430 2430 2430 24304300 4950 5880 5900 6750 780063 63 63 64 64 64
(1) Data referred to outlet chilled water temperature at 7°C; air to condenser at 35°C.(2) Data referred to hot water temperature at 40/45°C; air to gas/air heat exchanger at 7°C with 90%RH.(3) Mean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 400.3.50+N
Heat pump liquid chillers with axial fansTE
CHNI
CAL D
ATA
IDEN
TIFIC
ATIO
N REVERSO.SCREW.A.P.ELN “U”Heat pump air cooled packaged liquid chillers in extremely low noise version equipped with screw
compressors and axial fans. Casing type: “U”.
ELN Range (Extremely Low Noise)Screw compressors meet perfectly RC Group ELN (Extremely Low Noise) design.
High frequencies noise emission together with the almost absent vibrations, typical of screw compressors, allow the total
concentration of the design on the condensing part.
This attention produces a highly valuable product from the energy point of view (highest efficiency), with easy maintenance
(without any “heavy” noise deading box) and a durability of acoustic performances in time (noise deading materials decay).
205RC GROUP SpA • General Catalogue• 155.EN.0504
CHAR
ACTE
RIST
ICSHousing with aluminium profile frame •
with galvanized steel sheet panels
externally coated with PVC film
Main components housed in a •
technical compartment separated
from the air flow
Shell and tube gas/water heat exchanger •
Microprocessor control system •
Modulating condensing control •
Pump-Down stop •
Step-step cooling capacity control •
Oil cooling system •
Star/delta compressors starting system •
Door lock main switch •
Pumping group with 1 or 2 pumps •
Water tank •
Partial or total heat reclaim •
Mechanical or electronic flow switch •
Spring antivibration holders •
RS232C-RS422-RS485 serial line •
UDT, SQL or ASME VIII Div.1 approvals •
OPTI
ONAL
REVERSO.SCREW.A.P.ELN “U”R407C • 341 ÷ 832 kW
The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.
ServiceFastCompressors, electric board and electronic control system
housed in a technical compartment separated from the air flow to
allow standard maintenance with the unit in operation.HIGH
LIGHT
S
Patent
IDEA®As for all RC Group heat pump liquid chillers, this range products are
standard equipped with IDEA patented system for the control of
defrosting cycles through dynamic reading of working parameters.
IDEA is perfectly integrated with unit management and control system
to emphasize RC PROACTIVE working mode, granting in the mean time a
high energy saving (more of 20-30% on the average) and a higher
working continuity.
206 RC GROUP SpA • General Catalogue• 155.EN.0504
CILLI.IDROCOMPL.C.P.STD.Z1 - MODELCooling capacity (1) kWHeating capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgMean sound pressure level (3) dB(A)
CILLI.IDROCOMPL.C.P.STD.Z1 - MODELCooling capacity (1) kWHeating capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgMean sound pressure level (3) dB(A)
M.7.Z1 M.8.Z1 M.9.Z16,1 6,8 8,17 8 9,61 1 11 1 1
1242 1242 1242447 447 447844 844 844143 143 15358 58 58
T.8.Z1 T.9.Z1 T.13.Z1 T.16.Z1 T.19.Z16,8 8,1 12,6 14,1 15,68 9,6 14,5 16,7 17,71 1 1 1 11 1 1 1 1
1242 1242 1342 1342 1342447 447 497 497 497844 844 969 969 969145 153 189 204 24458 58 64 64 64
Heat pump liquid chillers with centrifugal fansTE
CHNI
CAL D
ATA
(1) Data referred to outlet chilled water temperature at 7°C; air to condenser at 35°C.(2) Data referred to hot water temperature at 40/45°C; air to gas/air heat exchanger at 7°C with 90%RH.(3) Mean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 230.1.50 for models “M” • 400.3.50+N for models “T”
IDEN
TIFIC
ATIO
N CILLI.IDROCOMPL.C.P.STD.Z1Heat pump air cooled packaged liquid chillers equipped with Scroll compressor centrifugal fan and
Idrocompl system.
CentriHigh reliability of IDROCOMPL system in heat pump version to meet all air conditioning requirements 12
months a year, in mild climate areas.
CENTRI version, with centrifugal fans for indoor and/or ducted installations makes this product the best
solution for small areas air conditioning, where the outdoor installation is not possible due to space and
environmental reasons.
207RC GROUP SpA • General Catalogue• 155.EN.0504
CHAR
ACTE
RIST
ICSHousing in galvanized steel sheet •
externally coated with PVC film
IDROCOMPL system •
Microprocessor control system •
Antifreeze system •
On/off condensing control •
Circulation pump •
Modulating condensing control •
Remote control board •
RS485 serial line •
Spring antivibration holders •
Door lock main switch •
OPTI
ONAL
CILLI.IDROCOMPL.C.P.STD.Z1R407C • 6 ÷ 16 kW
The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.
Pump&PressurePUMP&PRESSURE kit consists of a
circulation pump installed inside the
unit and of a control system of the
water plant pressure. Through this
kit CILLI IDROCOMPL P becomes a real
heat station only needing electrical
and hydraulic connections to be 100%
operating respecting all the current
norms.
HIGH
LIGHT
S
NoFreezeAnti-freeze system that totally
prevents the risks of freezing water
inside the evaporator.
208 RC GROUP SpA • General Catalogue• 155.EN.0504
CILLI.IDROCOMPL.C.P.STD.Z2 - MODELCooling capacity (1) kWHeating capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgMean sound pressure level (3) dB(A)
CILLI.IDROCOMPL.C.P.STD.Z2 - MODELCooling capacity (1) kWHeating capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgMean sound pressure level (3) dB(A)
T.24.Z2 T.28.Z2 T.34.Z220,7 24,8 28,723,6 26,9 32,9
2 2 21 1 1
1300 1300 1300895 895 895
1645 1645 1645465 470 48066 66 66
T.38.Z2 T.42.Z2 T.50.Z2 T.58.Z232,3 37,6 44,1 50,836,8 42,4 49 57,4
2 2 2 21 1 1 1
2000 2000 2000 2000895 895 895 895
1645 1645 1645 1645490 760 765 77068 69 69 69
Heat pump liquid chillers with centrifugal fansTE
CHNI
CAL D
ATA
(1) Data referred to outlet chilled water temperature at 7°C; air to condenser at 35°C.(2) Data referred to hot water temperature at 40/45°C; air to gas/air heat exchanger at 7°C with 90%RH.(3) Mean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 400.3.50+N
IDEN
TIFIC
ATIO
N CILLI.IDROCOMPL.C.P.STD.Z2Heat pump air cooled packaged liquid chillers equipped with Scroll compressors, centrifugal fans
and Idrocompl system.
Made2LastEven CILLI range heat pump liquid chillers are built according to MADE2LAST logic, usual for RC Group high capacity liquid chillers. A
housing designed to last in time and in any weather condition: flexible capillary pipes to avoid problems deriving from copper work
hardening; antivibration holders under the compressors to reduce vibration transmission to the housing; housing in anodized
aluminium; galvanized steel sheet parts; aluminium or stainless steel small parts.
209RC GROUP SpA • General Catalogue• 155.EN.0504
CHAR
ACTE
RIST
ICSHousing with aluminium profile frame •
with galvanized steel sheet panels
externally coated with PVC film
IDROCOMPL system •
Microprocessor control system •
Antifreeze system •
On/off condensing control •
Circulation pump •
Modulating condensing control •
Remote control board •
RS485 serial line •
Spring antivibration holders •
Door lock main switch •
OPTI
ONAL
CILLI.IDROCOMPL.C.P.STD.Z2R407C • 21÷ 51 kW
The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.
HIGH
LIGHT
S
ScrollThe state of the art technology in the field of medium/small size
compressors to grant excellent performances even in medium
and small dimensions plants.
Moreover SCROLL compressors grant a very high reliability
rate (MTBF) even in presence of reduced maintenance routine
plants.
9
8
7
6
55
13
12
11
10
2 31 2 4
1. Water outlet2. Cooling circuits3. Magnesium anode4. Breather valve5. Temperature sensors6. Water pump (optional)7. Safety valve8. Water inlet9. Discharge tap10. Water tank11. Expansion tank12. Anticondensate insulation13. Gas/water heat exchanger
Idrocompl® system
Patent
Idrocompl®Patented system including evaporator,
water tank and expansion tank in a
single component.
210 RC GROUP SpA • General Catalogue• 155.EN.0504
21.Z1 25.Z1 32.Z1 37.Z1 50.Z1 61.Z1G1 G1 G1 G3 G3 G3
18,9 21,4 28,6 34,9 46,2 55,622,8 26,1 34,3 41,1 53,8 66,3
1 1 1 1 1 11 1 1 1 1 1
1150 1150 1150 2000 2000 2000895 895 895 1040 1040 1040
1960 1960 1960 2010 2010 2010410 410 455 690 760 78059 59 66 60 68 68
36.Z2 42.Z2 50.Z2 64.Z2 74.Z2 87.Z2 100.Z2 124.Z2G3 G3 G3 G3 G5 G7 G7 G7
32,3 37,5 42,5 56 68,4 82,7 91,4 109,638,7 45,7 52,2 68,5 83,2 96,5 107,6 132,6
2 2 2 2 2 2 2 22 2 2 2 2 2 2 2
2000 2000 2000 2000 2600 3600 3600 36001040 1040 1040 1040 1200 1290 1290 12902010 2010 2010 2010 2240 2010 2010 2010720 740 750 820 1090 1480 1540 157059 60 64 68 70 69 69 69
Heat pump liquid chillers with centrifugal fansTE
CHNI
CAL D
ATA
(1) Data referred to outlet chilled water temperature at 7°C; air to condenser at 35°C.(2) Data referred to hot water temperature at 40/45°C; air to gas/air heat exchanger at 7°C with 90%RH.(3) Mean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 400.3.50+N
REVERSO.SCROLL.C.P.STD “G”Heat pump air cooled packaged liquid chillers equipped with Scroll compressors and centrifugal fans.
Casing type: ”G”.
IDEN
TIFIC
ATIO
N
REVERSO SCROLL represents the latest generation of heat pump liquid chillers with IDEA patented dynamic defrosting system
and combines current SCROLL technology with RC 40-year experience to grant investment durability in time.
CENTRI version, whose condensing section is equipped with centrifugal fans, allows the use of REVERSO liquid chillers even in
INDOOR installations.
REVERSO.SCROLL.C.P.STD “G” - MODELSizeCooling capacity (1) kWHeating capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgMean sound pressure level (3) dB(A)
REVERSO.SCROLL.C.P.STD “G” - MODELSizeCooling capacity (1) kWHeating capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgMean sound pressure level (3) dB(A)
211RC GROUP SpA • General Catalogue• 155.EN.0504
CHAR
ACTE
RIST
ICSHousing with aluminium profile frame •
with galvanized steel sheet panels
externally coated with PVC film
Main components housed in a •
technical compartment separated
from the air flow
Shell and tube gas/water heat exchanger •
Microprocessor control system •
Step-step condensing control •
Pump-Down stop •
Differential pressure switch •
on water side
Door lock main switch •
LNO Kit for about a 6 dB(A) noise •
pressure level reduction
Modulating condensing control •
Pumping group with 1 or 2 pumps •
Water tank •
Partial or total heat reclaim •
Mechanical flow switch •
Spring antivibration holders •
RS232C-RS422-RS485 serial line •
UDT, SQL or ASME VIII Div.1 approvals •
OPTI
ONAL
REVERSO.SCROLL.C.P.STD “G”R407C • 19 ÷ 110 kW
The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.
CentriCENTRI allows the static pressure supplied by the fan
section to conform to the possible pressure drops due to
duct system of condensing air intake and/or expulsion.
HIGH
LIGHT
S
AdaptiveRangeA great variety of versions,
models and optional extras to
meet many requirements in hi-
tech., hotels, cinemas and
shopping centres air
conditioning systems in any
climate condition.
Easy@ServeAll components are accessible
through frontal panels, without
removal of heavy noise deading
boxes.
212 RC GROUP SpA • General Catalogue• 155.EN.0504
21.Z1 25.Z1 32.Z1 37.Z1 50.Z1 61.Z1G3 G3 G3 G5 G5 G5
18,3 21,1 28,1 32,6 44,3 55,223,2 26,8 35,2 40,6 53,9 67,4
1 1 1 1 1 11 1 1 1 1 1
2000 2000 2000 2600 2600 26001040 1040 1040 1200 1200 12002010 2010 2010 2240 2240 2240610 610 650 860 920 93047 49 51 53 54 58
36.Z2 42.Z2 50.Z2 64.Z2 74.Z2 87.Z2 100.Z2 124.Z2G5 G5 G5 G5 G7 G8 G8 G8
30,3 35,9 42,2 55,6 62,7 81,7 90,2 107,138,3 45,7 53,1 69,7 79,3 97,6 109 133,7
2 2 2 2 2 2 2 22 2 2 2 2 2 2 2
2600 2600 2600 2600 3600 5170 5170 51701200 1200 1200 1200 1290 1290 1290 12902240 2240 2240 2240 2010 2050 2050 2050890 910 950 1000 1390 1880 1940 200052 55 54 58 55 56 56 56
Heat pump liquid chillers with centrifugal fansTE
CHNI
CAL D
ATA
(1) Data referred to outlet chilled water temperature at 7°C; air to condenser at 35°C.(2) Data referred to hot water temperature at 40/45°C; air to gas/air heat exchanger at 7°C with 90%RH.(3) Mean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 400.3.50+N
REVERSO.SCROLL.C.P.ELN “G”Heat pump air cooled packaged liquid chillers in extremely low noise version equipped with Scroll
compressors and centrifugal fans. Casing type: ”G”.
IDEN
TIFIC
ATIO
N
ELN Range (Extremely Low Noise)RC ELN design technology applied to REVERSO heat pumps.
Thanks to a specific design philosophy concentrated on removing the sound emissions at "source", REVERSO ELN
range requires no additional hardware that can result in detrimental product efficiency, maintenance and durability.
The use of the latest generation SCROLL compressors highlights the ELN range of characteristics making plant
selection of critical acoustic systems easy.
REVERSO.SCROLL.C.P.ELN “G” - MODELSizeCooling capacity (1) kWHeating capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgMean sound pressure level (3) dB(A)
REVERSO.SCROLL.C.P.ELN “G” - MODELSizeCooling capacity (1) kWHeating capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgMean sound pressure level (3) dB(A)
213RC GROUP SpA • General Catalogue• 155.EN.0504
CHAR
ACTE
RIST
ICSHousing with aluminium profile frame •
with galvanized steel sheet panels
externally coated with PVC film
Main components housed in a •
technical compartment separated
from the air flow
Shell and tube gas/water heat exchanger •
Microprocessor control system •
Modulating condensing control •
Pump-Down stop •
Differential pressure switch •
on water side
Door lock main switch •
Pumping group with 1 or 2 pumps •
Water tank •
Partial or total heat reclaim •
Mechanical flow switch •
Spring antivibration holders •
RS232C-RS422-RS485 serial line •
UDT, SQL or ASME VIII Div.1 approvals •
OPTI
ONAL
REVERSO.SCROLL.C.P.ELN “G”R407C • 18 ÷ 107 kW
The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.
Made2LastHousing designed to last in time and in any weather condition:
flexible capillary pipes to avoid problems deriving from copper
work hardening; antivibration holders under the compressors to
reduce vibration transmission to the housing; housing in anodized
aluminium; galvanized steel sheet parts; aluminium or stainless
steel small parts.
HIGH
LIGHT
S
AntirumbleRigid base frame made of a
multiple layer structure with high
noise absorption characteristics,
to reduce the noise emission
from the bottom of the unit. It is
an essential component for all
those installations where the
units are installed “raised” from
the floor through weight
distribution bars and/or
antivibration holders.
214 RC GROUP SpA • General Catalogue• 155.EN.0504
142.F2 188.F2 220.F2G7 G7 G8
126,4 165,7 193,5141,9 187,9 215,5
2 2 22 2 2
3600 3600 51701290 1290 12902010 2010 20501810 1975 251071 71 74
260.F2 300.F2G8 G8
233,9 260,3263,4 298,3
2 22 2
5170 51701290 12902050 20502775 283076 77
Heat pump liquid chillers with centrifugal fansTE
CHNI
CAL D
ATA
(1) Data referred to outlet chilled water temperature at 7°C; air to condenser at 35°C.(2) Data referred to hot water temperature at 40/45°C; air to gas/air heat exchanger at 7°C with 90%RH.(3) Mean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 400.3.50+N
REVERSO.RECIP.C.P.STD “G”Heat pump air cooled packaged liquid chillers equipped with reciprocating compressors and centrifugal
fans. Casing type: ”G”.
IDEN
TIFIC
ATIO
N
CentriThanks to CENTRI it is now possible to take advantage from the energy savings granted by IDEA patented
defrosting system even in INDOOR or ducted applications.
CENTRI version allows REVERSO air performances to conform to plant needs, about the need to duct the air
intake and/or expulsion or regarding the additional pressure drops due to grilles and/or insulating
systems.
REVERSO.RECIP.C.P.STD “G” - MODELSizeCooling capacity (1) kWHeating capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgMean sound pressure level (3) dB(A)
REVERSO.RECIP.C.P.STD “G” - MODELSizeCooling capacity (1) kWHeating capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgMean sound pressure level (3) dB(A)
215RC GROUP SpA • General Catalogue• 155.EN.0504
CHAR
ACTE
RIST
ICSHousing with aluminium profile frame •
with galvanized steel sheet panels
externally coated with PVC film
Main components housed in a •
technical compartment separated
from the air flow
Shell and tube gas/water heat exchanger •
Microprocessor control system •
Step-step condensing control •
Pump-Down stop •
Step-step cooling capacity control •
Door lock main switch •
LNO Kit for about a 6 dB(A) noise •
pressure level reduction
Modulating condensing control •
Pumping group with 1 or 2 pumps •
Water tank •
Partial or total heat reclaim •
Part-Winding compressors •
starting system
Mechanical flow switch •
Spring antivibration holders •
RS232C-RS422-RS485 serial line •
UDT, SQL or ASME VIII Div.1 approvals •
OPTI
ONAL
REVERSO.RECIP.C.P.STD “G”R407C • 126 ÷ 260 kW
The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.
CoolingDensityPlusOptimization system of internal layout to achieve the best
ratio between footprint and cooling capacity.
HIGH
LIGHT
S
MyNoiseSolutions range (STD-LNO) conceived to allow the selection
directly from the catalogue of the most suitable product for
the specific legislative or environmental demands regarding
the noise emission control.
216 RC GROUP SpA • General Catalogue• 155.EN.0504
REVERSO.RECIP.C.P.ELN “G” - MODELSizeCooling capacity (1) kWHeating capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgMean sound pressure level (3) dB(A)
142.F2 188.F2 220.F2G8 G8 G8
126,8 165,9 195,9145,8 192,6 226
2 2 22 2 2
5170 5170 51701290 1290 12902050 2050 20502140 2345 252560 61 67
Heat pump liquid chillers with centrifugal fansTE
CHNI
CAL D
ATA
(1) Data referred to outlet chilled water temperature at 7°C; air to condenser at 35°C.(2) Data referred to hot water temperature at 40/45°C; air to gas/air heat exchanger at 7°C with 90%RH.(3) Mean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 400.3.50+N
REVERSO.RECIP.C.P.ELN “G”Heat pump air cooled packaged liquid chillers in extremely low noise version equipped with reciprocating
compressors and centrifugal fans. Casing type: ”G”.
IDEN
TIFIC
ATIO
N
The highest energy saving, the lowest noise emission and the possibility of INDOOR installation in a unique product.
Thanks to REVERSO CENTRI version it is possible to take advantage from IDEA dynamic defrosting system even in those
situations where it is necessary to install the chiller in dedicated areas or there is the need of additional acoustic
restraint systems (barriers) to achieved imposed acoustic parameters.
All is managed by PROACTIVE logic characterising all RC microprocessor controls range.
217RC GROUP SpA • General Catalogue• 155.EN.0504
CHAR
ACTE
RIST
ICSHousing with aluminium profile frame •
with galvanized steel sheet panels
externally coated with PVC film
Main components housed in a •
technical compartment separated
from the air flow
Shell and tube gas/water heat exchanger •
Microprocessor control system •
Modulating condensing control •
Pump-Down stop •
Step-step cooling capacity control •
Door lock main switch •
Pumping group with 1 or 2 pumps •
Water tank •
Partial or total heat reclaim •
Part-Winding compressors •
starting system
Mechanical or electronic flow switch •
Spring antivibration holders •
RS232C-RS422-RS485 serial line •
UDT, SQL or ASME VIII Div.1 approvals •
OPTI
ONAL
REVERSO.RECIP.C.P.ELN “G”R407C • 130 ÷ 200 kW
The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.
Easy@ServeAll components are accessible through frontal
panels, without removal of heavy noise deading
boxes.
HIGH
LIGHT
S
PumpStationA complete built-in pumping station (without size increase),
equipped with instruments and safety devices totally integrated
with the unit control system in order to emphasize RC PROACTIVE
working.
218 RC GROUP SpA • General Catalogue• 155.EN.0504
RC GROUP liquid chillers: wide range of units in terms of models, compressors and refrigerants.
MULTIFUNCTION CHILLERSThese chillers are specifically designed for 4 pipe air conditioning systems, where the simultaneous production of hot water andchilled water is requested. They claim a total reliability thanks to the experience acquired during more than 10 years and thanks
to hundred of installations both in Italy and abroad.The units are available both with axial and centrifugal fans.
ELN RANGE (EXTREMELY LOW NOISE)For over 20 years RC Group has offered a standard catalogued range of units designed specifically to provide the "lowest noiseemission" equipment on the market.The design and continuous development of the ELN range has avoided using "bolt-on" acoustic kits, adding weight and reducing theserviceability of the equipment but instead has concentrated on removing the sound emissions at "source".By careful selection of matched components and innovative design of the condensing coil surface and airflow distribution, the ELN rangehas evolved into one of the quietest and thermally efficient Packaged Chillers in today's market place.This one solution grants : high efficiency, extremely low sound emissions and easy maintenance, no need to remove heavy noise reductionkits or acoustic barriers. The performance and durability of the RC Group solution lasts with time, unlike that of the materials of the"bolt-on" sound reduction kits that can decay over time.All RC Group chillers are available in the ELN range, including versions with axial or centrifugal fans.
PLAN
T TY
PEMultifunction air cooledliquid chillers
219RC GROUP SpA • General Catalogue• 155.EN.0504
Multifunction air cooledliquid chillers
MULTIPLO.SCROLL.A.STD “G” • R407C • 60 ÷ 115 kWMultifunction liquid chillers with scroll compressors.
MULTIPLO.SCROLL.A.ELN “G” • R407C • 60 ÷ 115 kWExtremely low noise multifunction liquid chillers with scroll
compressors.
MULTIPO.RECIP.A.STD “G” • R407C • 130 ÷ 282 kWMultifunction liquid chillers with reciprocating compressors.
MULTIPLO.RECIP.A.ELN “G” • R407C • 120 ÷ 282 kWExtremely low noise multifunction liquid chillers with reciprocating
compressors.
MULTIPLO.SCROLL.C.STD “G” • R407C • 57 ÷ 115 kWMultifunction liquid chillers with scroll compressors.
MULTIPLO.SCROLL.C.ELN “G” • R407C • 55 ÷ 115 kWExtremely low noise multifunction liquid chillers with scroll compressors.
MULTIPLO.RECIP.C.STD “G” • R407C • 128 ÷ 282 kWMultifunction liquid chillers with reciprocating compressors.
MULTIPLO.RECIP.C.ELN “G” • R407C • 121 ÷ 282 kWExtremely low noise multifunction liquid chillers with reciprocating
compressors.
220 AXIAL FANS
222
224
226
228 CENTRIFUGAL FANS
230
232
234
INDE
X
220 RC GROUP SpA • General Catalogue• 155.EN.0504
MULTIPLO.SCROLL.A.STD “G” - MODELSizeCooling capacity (1) kWHeating capacity (2) kWCooling capacity (3) kWHeating capacity (3) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgMean sound pressure level (3) dB(A)
64.Z2 74.Z2 100.Z2 124.Z2G6 G6 G8B G8B
62,1 69,6 93,7 109,174,3 84,1 112,1 132,559,5 69,4 94,6 114,981,5 94,5 129,7 158,9
2 2 2 22 2 2 2
3600 3600 5170 51701290 1290 1290 12901690 1690 1730 17301060 1160 1485 153564 64 64 64
(1) Only cooling: Data referred to outlet chilled water temperature at 7°C; air to condenser at 35°C.(2) Only heating: Data referred to hot water temperature at 40/45°C; air to gas/air heat exchanger at 7°C with 90%RH.(3) Cooling and heating: Data referred to outlet chilled water temperature at 7°C; hot water temperature 40/45°CMean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 400.3.50+N
Multifunction liquid chillers with axial fansTE
CHNI
CAL D
ATA
MULTIPLO.SCROLL.A.P.STD “G”Multifunction air cooled packaged liquid chillers equipped with Scroll compressors and axial fans.
Casing type: ”G”.
IDEN
TIFIC
ATIO
N
MULTIPLO: multifunction unit with total reclaim for simultaneous production of chilled and hot water for “comfort” and
industrial applications in every climatic area. It is recommended for Hotels, Health Centres, Hospitals and all
installations where the simultaneous production of chilled and hot water is required all year long.
As for REVERSO units, also MULTIPLO units are equipped with IDEA, RC Group “patented” defrost system with dynamic
reading of the working parameters. Thanks to proprietary software, IDEA senses the real presence of brine on the
coil, granting defrosting cycles limited to the real working conditions to bring a high energy saving (more than 20-30%
on the average) and a higher working continuity.
221RC GROUP SpA • General Catalogue• 155.EN.0504
CHAR
ACTE
RIST
ICSHousing with aluminium profile frame •
with galvanized steel sheet panels
externally coated with PVC film
Main components housed in a •
technical compartment separated
from the air flow
Plate gas/water heat exchanger •
Microprocessor control system •
Modulating condensing control •
Pump-Down stop •
Differential pressure switch •
on water side
Door lock main switch •
Pumping group with 1 or 2 pumps •
Chilled water tank •
Hot water tank •
Mechanical flow switch •
Spring antivibration holders •
RS232C-RS422-RS485 serial line •
UDT, SQL or ASME VIII Div.1 approvals •
OPTI
ONAL
MULTIPLO.SCROLL.A.STD “G”R407C • 60 ÷ 115 kW
The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.
ScrollThe state of the art technology in the field of medium/small size
compressors to grant excellent performances even in medium/
small plants.
SCROLL compressors grant a high reliability rate (MTBF), which
is an essential requirement in plants with continuous working (12
months a year) and it is specific of MULTIPLO applications.
HIGH
LIGHT
S
MateMATE integrated control system for a stepless speed modulation of
condensers fans.
222 RC GROUP SpA • General Catalogue• 155.EN.0504
MULTIPLO.SCROLL.A.ELN “G” - MODELSizeCooling capacity (1) kWHeating capacity (2) kWCooling capacity (3) kWHeating capacity (3) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgMean sound pressure level (3) dB(A)
64.Z2 74.Z2 100.Z2 124.Z2G6 G6 G8B G8B
56,8 63,6 87,6 107,170,3 80,1 108 13459,5 69,4 94,6 114,981,5 94,5 129,7 158,9
2 2 2 22 2 2 2
3600 3600 5170 51701290 1290 1290 12901690 1690 1730 17301060 1160 1485 153554 56 56 57
(1) Only cooling: Data referred to outlet chilled water temperature at 7°C; air to condenser at 35°C.(2) Only heating: Data referred to hot water temperature at 40/45°C; air to gas/air heat exchanger at 7°C with 90%RH.(3) Cooling and heating: Data referred to outlet chilled water temperature at 7°C; hot water temperature 40/45°CMean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 400.3.50+N
Multifunction liquid chillers with axial fansTE
CHNI
CAL D
ATA
MULTIPLO.SCROLL.A.P.ELN “G”Multifunction air cooled packaged liquid chillers in extremely low noise equipped with Scroll compressors
and axial fans. Casing type: ”G”.
IDEN
TIFIC
ATIO
N
MULTIPLO: multifunction unit with total reclaim for simultaneous production of chilled and hot water for “comfort” and
industrial applications in every climatic area.
This series represents the ELN (Extremely Low Noise) range of this particular product.
This product being particularly suitable for Hospitals, Health Centres and Hotels needs, ELN version represents the perfect
solution to respect the requested acoustic parameters (often requested by law) for this kind of applications. RC ELN design
keeps the easy installation and maintenance characteristics of the product, granting an acoustic and cooling performances
durability in time.
223RC GROUP SpA • General Catalogue• 155.EN.0504
CHAR
ACTE
RIST
ICSHousing with aluminium profile frame •
with galvanized steel sheet panels
externally coated with PVC film
Main components housed in a •
technical compartment separated
from the air flow
Plate gas/water heat exchanger •
Microprocessor control system •
Modulating condensing control •
Pump-Down stop •
Differential pressure switch •
on water side
Door lock main switch •
Pumping group with 1 or 2 pumps •
Chilled water tank •
Hot water tank •
Mechanical flow switch •
Spring antivibration holders •
RS232C-RS422-RS485 serial line •
UDT, SQL or ASME VIII Div.1 approvals •
OPTI
ONAL
MULTIPLO.SCROLL.A.ELN “G”R407C • 60 ÷ 115 kW
The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.
Easy@ServeAll components are accessible through frontal panels, without
removal of heavy noise reduction boxes.HIGH
LIGHT
S
QuickStartWhatever is needed for a correct unit working is built-in.
Electrical and water connections only are needed at start-up for
a complete installation in full compliance with all the current
norms.
224 RC GROUP SpA • General Catalogue• 155.EN.0504
MULTIPLO.RECIP.A.STD “G” - MODELSizeCooling capacity (1) kWHeating capacity (2) kWCooling capacity (3) kWHeating capacity (3) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgMean sound pressure level (3) dB(A)
142.F2 188.F2 220.F2 260.F2 300.F2G8B G8 G8 G8 G8
128,9 167,6 194 236,3 261,7148,5 195,8 229,2 270,9 305,1136,3 172,4 203,8 246 282,7180,1 227,7 271,5 323 377,7
2 2 2 2 22 2 2 2 2
5170 5170 5170 5170 51701290 1290 1290 1290 12901730 2280 2280 2280 22801800 1950 2260 2600 265065 65 65 73 73
(1) Only cooling: Data referred to outlet chilled water temperature at 7°C; air to condenser at 35°C.(2) Only heating: Data referred to hot water temperature at 40/45°C; air to gas/air heat exchanger at 7°C with 90%RH.(3) Cooling and heating: Data referred to outlet chilled water temperature at 7°C; hot water temperature 40/45°CMedium noise pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 400.3.50+N
Multifunction liquid chillers with axial fansTE
CHNI
CAL D
ATA
MULTIPLO.RECIP.A.P.STD “G”Multifunction air cooled packaged liquid chillers equipped with reciprocating compressors and axial fans.
Casing type: ”G”.
IDEN
TIFIC
ATIO
N
MULTIPLO: multifunction unit with total reclaim for simultaneous production of chilled and hot water equipped with high
efficiency reciprocating compressors and condensing section with latest generation axial fans. Multiplo is suitable for those
applications where the simultaneous production of chilled and hot water for distribution through plant with four pipes is
required all year long.
PUMPSTATION system installation (a real built-in station with pumps dedicated to hot and chilled water distribution),
transforms MULTIPLO into an independent and auto-controlled heating station without increase of plant dimensions.
This grants a strong reduction of installation costs limiting it to electrical and hydraulic connections.
225RC GROUP SpA • General Catalogue• 155.EN.0504
CHAR
ACTE
RIST
ICSHousing with aluminium profile frame •
with galvanized steel sheet panels
externally coated with PVC film
Main components housed in a •
technical compartment separated
from the air flow
Plate gas/water heat exchanger •
Microprocessor control system •
Modulating condensing control •
Pump-Down stop •
Door lock main switch •
Pumping group with 1 or 2 pumps •
Chilled water tank •
Hot water tank •
Mechanical flow switch •
Part-Winding compressors •
starting system
Spring antivibration holders •
RS232C-RS422-RS485 serial line •
UDT, SQL or ASME VIII Div.1 approvals •
OPTI
ONAL
MULTIPLO.RECIP.A.STD “G”R407C • 130 ÷ 282 kW
The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.
Made2LastAlso MULTIPLO liquid chillers are designed according to MADE2LAST
logic: flexible capillary pipes to avoid problems deriving from
copper work hardening; antivibration holders under the
compressors to reduce vibration transmission to the housing;
housing in anodized aluminium; galvanized steel sheet parts;
aluminium or stainless steel small parts. A housing designed to last
in time and in any weather condition.
HIGH
LIGHT
S
BufferTankPUMPSTATION system can be
completed with BUFFERTANK
optional, integrated water tank to
increase plant inertia with an
important reduction of
compressors start and stop for
more reliability and operating life.
All without any increase of
footprint.
226 RC GROUP SpA • General Catalogue• 155.EN.0504
MULTIPLO.RECIP.A.ELN “G” - MODELSizeCooling capacity (1) kWHeating capacity (2) kWCooling capacity (3) kWHeating capacity (3) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgMean sound pressure level (3) dB(A)
142.F2 188.F2 220.F2 260.F2 300.F2G8B G8 G8 G8 G8120 155,3 183,1 222,3 251,6
139,9 184,1 219,3 256,2 295,7136,3 172,4 203,8 246 282,7180,1 227,7 271,5 323 377,7
2 2 2 2 22 2 2 2 2
5170 5170 5170 5170 51701290 1290 1290 1290 12901730 2280 2280 2280 22801800 1950 2260 2600 265057 57 58 65 65
(1) Only cooling: Data referred to outlet chilled water temperature at 7°C; air to condenser at 35°C.(2) Only heating: Data referred to hot water temperature at 40/45°C; air to gas/air heat exchanger at 7°C with 90%RH.(3) Cooling and heating: Data referred to outlet chilled water temperature at 7°C; hot water temperature 40/45°CMean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 400.3.50+N
Multifunction liquid chillers with axial fansTE
CHNI
CAL D
ATA
MULTIPLO.RECIP.A.P.ELN “G”Multifunction air cooled packaged liquid chillers in extremely low noise version equipped with
reciprocating compressors and axial fans. Casing type: ”G”.
IDEN
TIFIC
ATIO
N
MULTIPLO: multifunction unit with total reclaim for simultaneous production of chilled and hot water equipped with high
efficiency reciprocating compressors and condensing section with latest generation axial fans.
The ELN (Extremely Low Noise) version of this range grants excellent noise levels, typical of RC ELN logic, keeping one of the
highest easy installation and maintenance characteristic of this field.
All operations are controlled by MP99 microprocessor control system equipped with RC PROACTIVE proprietary logic to
grant continuous operation even in emergency situations.
227RC GROUP SpA • General Catalogue• 155.EN.0504
CHAR
ACTE
RIST
ICSHousing with aluminium profile frame •
with galvanized steel sheet panels
externally coated with PVC film
Main components housed in a •
technical compartment separated
from the air flow
Plate gas/water heat exchanger •
Microprocessor control system •
Modulating condensing control •
Pump-Down stop •
Door lock main switch •
Pumping group with 1 or 2 pumps •
Chilled water tank •
Hot water tank •
Mechanical flow switch •
Part-Winding compressors •
starting system
Spring antivibration holders •
RS232C-RS422-RS485 serial line •
UDT, SQL or ASME VIII Div.1 approvals •
OPTI
ONAL
MULTIPLO.RECIP.A.ELN “G”R407C • 120 ÷ 282 kW
The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.
AdaptiveRangeA great variety of versions, models and optional to meet many
requirements in hi-tech. applications in Hotels, Health Centres,
Hospitals and all structures requiring a simultaneous production
of chilled or hot water all year long in mild climate areas.
HIGH
LIGHT
S
ServiceFastCompressors, electric board and electronic control system
housed in a technical compartment separated from the air flow to
allow standard maintenance with the unit in operation.
228 RC GROUP SpA • General Catalogue• 155.EN.0504
MULTIPLO.SCROLL.C.STD “G” - MODELSizeCooling capacity (1) kWHeating capacity (2) kWCooling capacity (3) kWHeating capacity (3) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgMean sound pressure level (3) dB(A)
64.Z2 74.Z2 100.Z2 124.Z2G7 G7 G8 G8
56,8 65,2 93,7 111,370,3 82,8 112,1 13459,5 69,4 94,6 114,981,5 94,5 129,7 158,9
2 2 2 22 2 2 2
3600 3600 5170 51701290 1290 1290 12902010 2010 2050 20501400 1330 2065 208566 68 65 67
(1) Only cooling: Data referred to outlet chilled water temperature at 7°C; air to condenser at 35°C.(2) Only heating: Data referred to hot water temperature at 40/45°C; air to gas/air heat exchanger at 7°C with 90%RH.(3) Cooling and heating: Data referred to outlet chilled water temperature at 7°C; hot water temperature 40/45°CMean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 400.3.50+N
Multifunction liquid chillers with centrifugal fansTE
CHNI
CAL D
ATA
MULTIPLO.SCROLL.C.P.STD “G”Multifunction air cooled packaged liquid chillers equipped with Scroll compressors and centrifugal fans.
Casing type: ”G”.
IDEN
TIFIC
ATIO
N
CentriMULTIPLO: multifunction unit with total reclaim for simultaneous production of chilled and hot water equipped with last
generation SCROLL compressors and CENTRI fan section with centrifugal fans.
The use of centrifugal fans makes this MULTIPLO series suitable also for INDOOR installations.
Indeed CENTRI allows the static pressure supplied by the fan section to conform to the possible pressure drops due to duct
system of condensing air intake and/or expulsion.
229RC GROUP SpA • General Catalogue• 155.EN.0504
CHAR
ACTE
RIST
ICSHousing with aluminium profile frame •
with galvanized steel sheet panels
externally coated with PVC film
Main components housed in a •
technical compartment separated
from the air flow
Plate gas/water heat exchanger •
Microprocessor control system •
Modulating condensing control •
Pump-Down stop •
Differential pressure switch •
on water side
Door lock main switch •
Pumping group with 1 or 2 pumps •
Chilled water tank •
Hot water tank •
Mechanical flow switch •
Spring antivibration holders •
RS232C-RS422-RS485 serial line •
UDT, SQL or ASME VIII Div.1 approvals •
OPTI
ONAL
MULTIPLO.SCROLL.C.STD “G”R407C • 57 ÷ 115 kW
The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.
CoolingDensityPlusOptimization internal layout to achieve the best ratio between
footprint and cooling capacity.
HIGH
LIGHT
S
PumpStationA complete built-in pumping station equipped with pumps
for hot and chilled water distribution transforms
MULTIPLO into an independent and auto-controlled
heating/cooling “package” without increasing plant
dimensions.
This solution allows a strong reduction of installation
costs limiting it to a the unit electrical and hydraulic
connections.
230 RC GROUP SpA • General Catalogue• 155.EN.0504
MULTIPLO.SCROLL.C.ELN “G” - MODELSizeCooling capacity (1) kWHeating capacity (2) kWCooling capacity (3) kWHeating capacity (3) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgMean sound pressure level (3) dB(A)
64.Z2 74.Z2 100.Z2 124.Z2G7 G7 G8 G8
55,1 63,3 87,8 109,369,3 81,6 108 135,459,5 69,4 94,6 114,981,5 94,5 129,7 158,9
2 2 2 22 2 2 2
3600 3600 5170 51701290 1290 1290 12902010 2010 2050 20501400 1330 2065 208564 66 58 62
(1) Only cooling: Data referred to outlet chilled water temperature at 7°C; air to condenser at 35°C.(2) Only heating: Data referred to hot water temperature at 40/45°C; air to gas/air heat exchanger at 7°C with 90%RH.(3) Cooling and heating: Data referred to outlet chilled water temperature at 7°C; hot water temperature 40/45°CMean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 400.3.50+N
Multifunction liquid chillers with centrifugal fansTE
CHNI
CAL D
ATA
MULTIPLO.SCROLL.C.P.ELN “G”Multifunction air cooled packaged liquid chillers in extremely low noise version equipped with Scroll
compressors and centrifugal fans. Casing type: ”G”.
IDEN
TIFIC
ATIO
N
ELN Range (Extremely Low Noise)Over 20 years of experience in sound reduction techniques together with SCROLL technology enable RC Group to grant excellent
sound emission levels for this equipment.
These top sound levels are the result of a specific design philosophy concentrated on removing the sound emissions at "source",
without using "bolt-on" acoustic kits.
The use of the latest generation SCROLL compressors highlights the ELN range of characteristics making plant selection of critical
acoustic systems easy.
231RC GROUP SpA • General Catalogue• 155.EN.0504
CHAR
ACTE
RIST
ICSHousing with aluminium profile frame •
with galvanized steel sheet panels
externally coated with PVC film
Main components housed in a •
technical compartment separated
from the air flow
Plate gas/water heat exchanger •
Microprocessor control system •
Modulating condensing control •
Pump-Down stop •
Differential pressure switch •
on water side
Door lock main switch •
Pumping group with 1 or 2 pumps •
Chilled water tank •
Hot water tank •
Mechanical flow switch •
Spring antivibration holders •
RS232C-RS422-RS485 serial line •
UDT, SQL or ASME VIII Div.1 approvals •
OPTI
ONAL
MULTIPLO.SCROLL.C.ELN “G”R407C • 55 ÷ 115 kW
The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.
SleepWellProprietary software for
lowest noise emission working
during the night.
Essential requirement for the
respect of acoustic norms in
plants devoted to Hospitals and
Hotels.
HIGH
LIGHT
S
AntirumbleRigid base frame made of a multiple layer structure with high noise
absorption characteristics, to reduce the noise emission from the
bottom of the unit. It is an essential component for all those
installations where the units are installed “raised” from the floor
through weight distribution bars and/or antivibration holders.
232 RC GROUP SpA • General Catalogue• 155.EN.0504
MULTIPLO.RECIP.C.STD “G” - MODELSizeCooling capacity (1) kWHeating capacity (2) kWCooling capacity (3) kWHeating capacity (3) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgMean sound pressure level (3) dB(A)
142.F2 188.F2 220.F2 260.F2 300.F2G8 G8 G8 G8 G8
128,1 165,6 193,9 229,1 254,1147,8 194,2 223,4 262,5 296,5136,3 172,4 203,8 246 282,7180,1 227,7 271,5 323 377,7
2 2 2 2 22 2 2 2 2
5170 5170 5170 5170 51701290 1290 1290 1290 12902050 2050 2050 2050 20502310 2480 2570 2960 300069 71 75 76 77
(1) Only cooling: Data referred to outlet chilled water temperature at 7°C; air to condenser at 35°C.(2) Only heating: Data referred to hot water temperature at 40/45°C; air to gas/air heat exchanger at 7°C with 90%RH.(3) Cooling and heating: Data referred to outlet chilled water temperature at 7°C; hot water temperature 40/45°CMean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 400.3.50+N
Multifunction liquid chillers with centrifugal fansTE
CHNI
CAL D
ATA
MULTIPLO.RECIP.C.P.STD “G”Multifunction air cooled packaged liquid chillers equipped with reciprocating compressors and centrifugal
fans. Casing type: ”G”.
IDEN
TIFIC
ATIO
N
MULTIPLO: multifunction unit with total reclaim for simultaneous production of chilled and hot water
equipped with high efficiency reciprocating compressors and condensing section with centrifugal fans.
Thanks to CENTRI it is now possible to take advantage from MULTIPLO multipurpose flexibility even in
INDOOR or ducted applications.
Indeed CENTRI version allows the MULTIPLO air performances to conform to the plant needs, regarding
pressure drops due to grilles and/or insulation systems and to the need of a duct system for air intake
and/or expulsion.
233RC GROUP SpA • General Catalogue• 155.EN.0504
CHAR
ACTE
RIST
ICSHousing with aluminium profile frame •
with galvanized steel sheet panels
externally coated with PVC film
Main components housed in a •
technical compartment separated
from the air flow
Plate gas/water heat exchanger •
Microprocessor control system •
Modulating condensing control •
Pump-Down stop •
Door lock main switch •
Pumping group with 1 or 2 pumps •
Chilled water tank •
Hot water tank •
Mechanical flow switch •
Part-Winding compressors •
starting system
Spring antivibration holders •
RS232C-RS422-RS485 serial line •
UDT, SQL or ASME VIII Div.1 approvals •
OPTI
ONAL
MULTIPLO.RECIP.C.STD “G”R407C • 128 ÷ 282 kW
The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.
MyNoiseSolutions range (STD-LNO) conceived to allow the selection
directly from the catalogue of the most suitable product for the
specific legislative or environmental demands regarding the
noise emission control.
HIGH
LIGHT
S
PumpStationA complete built-in pumping station
(without size increase), equipped
with instruments and safety
devices totally integrated with the
unit control system in order to
emphasize RC PROACTIVE working;
possibility to integrate
PumpStation with water tank
without any increase in footprint.
234 RC GROUP SpA • General Catalogue• 155.EN.0504
MULTIPLO.RECIP.C.ELN “G” - MODELSizeCooling capacity (1) kWHeating capacity (2) kWCooling capacity (3) kWHeating capacity (3) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgMean sound pressure level (3) dB(A)
142.F2 188.F2 220.F2 260.F2 300.F2G8 G8 G8 G8 G8
121,8 156,3 183,5 221,7 250,4141,6 185,8 214,1 254,7 292,7136,3 172,4 203,8 246 282,7180,1 227,7 271,5 323 377,7
2 2 2 2 22 2 2 2 2
5170 5170 5170 5170 51701290 1290 1290 1290 12902050 2050 2050 2050 20502310 2480 2570 2960 300062 64 69 72 74
(1) Only cooling: Data referred to outlet chilled water temperature at 7°C; air to condenser at 35°C.(2) Only heating: Data referred to hot water temperature at 40/45°C; air to gas/air heat exchanger at 7°C with 90%RH.(3) Cooling and heating: Data referred to outlet chilled water temperature at 7°C; hot water temperature 40/45°CMean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 400.3.50+N
Multifunction liquid chillers with centrifugal fansTE
CHNI
CAL D
ATA
MULTIPLO.RECIP.C.P.ELN “G”Multifunction air cooled packaged liquid chillers in extremely low noise version equipped with
reciprocating compressors and centrifugal fans. Casing type: ”G”.
IDEN
TIFIC
ATIO
N
MULTIPLO: multifunction unit with total reclaim for simultaneous production of chilled and hot water equipped with high efficiency
reciprocating compressors and condensing section with centrifugal fans.
ELN (Extremely Low Noise) version with the highest energy saving, the lowest noise emission and possibility of INDOOR
installation, all gathered in a single unit.
Thanks to MULTIPLO ELN CENTRI version it is now possible to take advantage from the simultaneous production of hot and chilled
water even in those situations where it is necessary to install the chiller in dedicated areas or there is the need of additional
acoustic restraint systems (barriers) to achieved imposed acoustic parameters.
All is managed by PROACTIVE logic characterising all RC microprocessor controls range.
235RC GROUP SpA • General Catalogue• 155.EN.0504
CHAR
ACTE
RIST
ICSHousing with aluminium profile frame •
with galvanized steel sheet panels
externally coated with PVC film
Main components housed in a •
technical compartment separated
from the air flow
Plate gas/water heat exchanger •
Microprocessor control system •
Modulating condensing control •
Pump-Down stop •
Door lock main switch •
Pumping group with 1 or 2 pumps •
Chilled water tank •
Hot water tank •
Mechanical flow switch •
Part-Winding compressors •
starting system
Spring antivibration holders •
RS232C-RS422-RS485 serial line •
UDT, SQL or ASME VIII Div.1 approvals •
OPTI
ONAL
MULTIPLO.RECIP.C.ELN “G”R407C • 121 ÷ 282 kW
The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.
Easy@ServeAll components are accessible through frontal panels,
without removal of heavy noise deading boxes.
HIGH
LIGHT
S
AntirumbleRigid base frame made of a multiple layer structure with high noise
absorption characteristics, to reduce the noise emission from the
bottom of the unit. It is an essential component for all those
installations where the units are installed “raised” from the floor
through weight distribution bars and/or antivibration holders.
236 RC GROUP SpA • General Catalogue• 155.EN.0504
RC GROUP liquid chillers: wide range of units in terms of models, compressors and refrigerants.
WATER COOLED LIQUID CHILLERSRC GROUP liquid chillers are equipped with Scroll, reciprocating or screw compressors.Energy efficiency is one of the main feature of all models; the wide range of accessories and versions, exchanger for total or
partial condensing heat reclaim are available, allow multiple applications.The latest generation and high reliability microprocessor control system is equipped with RC PROACTIVE proprietary system suitablefor connection with all main Building Management and Remote Monitoring systems available today on the market.
PLAN
T TY
PEWater cooled liquid chillers
237RC GROUP SpA • General Catalogue• 155.EN.0504
Water cooledliquid chillers
AQUA.IDROCOMPL.W.NRM.Z1 • R407C • 6 ÷ 18 kWIdrocompl liquid chillers with scroll compressor.
AQUA.IDROCOMPL.W.NRM.Z2 • R407C • 23 ÷ 57 kWIdrocompl liquid chillers with scroll compressors.
COLDPACK.W.NRM • R407C • 50 ÷ 210 kWLiquid chillers with scroll compressors.
FRIGO.SCROLL.W.NRM “G” • R407C • 15 ÷ 137 kWLiquid chillers with scroll compressors.
FRIGO.RECIP.W.NRM “G” • R407C • 150 ÷ 310 kWLiquid chillers with reciprocating compressors.
FRIGO.RECIP.W.NRM “S” • R407C • 232 ÷ 3440 kWLiquid chillers with reciprocating compressors.
FRIGO.SCREW.W.NRM “V” • R407C • 130 ÷ 1403 kWLiquid chillers with screw compressors.
FRIGO.SCREW.W.NRM “V” • R407C • 1397 ÷ 4200 kWLiquid chillers with screw compressors.
238 WATER COOLING
240
242
244
246
248
250
252
INDE
X
238 RC GROUP SpA • General Catalogue• 155.EN.0504
AQUA.IDROCOMPL.W.NRM.Z1 - MODELCooling capacity (1) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgNoise pressure level (2) dB(A)
AQUA.IDROCOMPL.W.NRM.Z1 - MODELCooling capacity (1) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgNoise pressure level (2) dB(A)
M.7.Z1 M.8.Z1 M.9.Z16,5 7,2 9,11 1 11 1 1
667 667 667497 497 497969 969 969125 125 12548 50 50
T.8.Z1 T.9.Z1 T.13.Z1 T.16.Z1 T.19.Z17,2 9,1 12,9 15,2 18,11 1 1 1 11 1 1 1 1
667 667 667 667 667497 497 497 497 497969 969 969 969 969125 125 145 150 16050 50 52 52 52
(1) Data referred to chilled water temperature 12/7°C; condenser inlet water at 30°C.(2) Noise pressure level 1m far from the unit in free field conditions.POWER SUPPLY: 230.1.50 for models “M” • 400.3.50+N for models “T”
Water cooled liquid chillersTE
CHNI
CAL D
ATA
AQUA.IDROCOMPL.W.NRM.Z1Water cooled packaged liquid chillers equipped with Scroll compressor, plate condenser and Idrocompl
system.
Water cooled liquid chillers equipped with latest generation SCROLL compressors and IDROCOMPL international
patented integrated system.
IDROCOMPL includes also NOFREEZE working mode, totally protecting from the risks due to water freezing
inside the evaporator.
IDEN
TIFIC
ATIO
N
239RC GROUP SpA • General Catalogue• 155.EN.0504
CHAR
ACTE
RIST
ICSHousing made of galvanized steel sheet •
externally coated with PVC film
IDROCOMPL system •
Plate condenser •
Microprocessor control system •
Antifreeze system •
Circulating pump •
Water regulating valve •
Remote control board •
RS485 serial line card • OPTI
ONAL
The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.
AQUA.IDROCOMPL.W.NRM.Z1R407C • 6 ÷ 18 kW
9
8
7
6
55
13
12
11
10
2 31 2 4
1. Water outlet2. Cooling circuits3. Magnesium anode4. Breather valve5. Temperature sensors6. Water pump (optional)7. Safety valve8. Water inlet9. Discharge tap10. Water tank11. Expansion tank12. Anticondensate insulation13. Gas/water heat exchanger
Idrocompl® System
HIGH
LIGHT
S
Patent
Idrocompl®Patented system including
in a single package the
evaporator, the water
tank and the expansion
tank.
240 RC GROUP SpA • General Catalogue• 155.EN.0504
AQUA.IDROCOMPL.W.NRM.Z2 - MODELCooling capacity (1) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgNoise pressure level (2) dB(A)
AQUA.IDROCOMPL.W.NRM.Z2 - MODELCooling capacity (1) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgNoise pressure level (2) dB(A)
T.24.Z2 T.28.Z2 T.34.Z2 T.38.Z223 27,6 32,9 37,12 2 2 21 1 1 1
1342 1342 1342 1342497 497 497 497
1340 1340 1340 1340265 275 300 32554 54 54 54
T.42.Z2 T.50.Z2 T.58.Z241,4 49,3 57
2 2 21 1 1
1608 1608 1608708 708 708
1360 1360 1360482 487 50555 55 55
(1) Data referred to chilled water temperature 12/7°C; condenser inlet water at 30°C.(2) Noise pressure level 1m far from the unit in free field conditions.POWER SUPPLY: 400.3.50+N
Water cooled liquid chillersTE
CHNI
CAL D
ATA
IDEN
TIFIC
ATIO
N AQUA.IDROCOMPL.W.NRM.Z2Water cooled packaged liquid chillers equipped with Scroll compressors, plate condenser and Idrocompl
system.
AQUA IDROCOMPL, water cooled liquid chillers equipped with latest generation SCROLL compressors and IDROCOMPL international
patented integrated system.
Thanks to QUICK START design logic, AQUA IDROCOMPL can be considered plug and play units.
For the start-up the units only need electrical and hydraulic connections for a complete installation in compliance with all the
current norms.
241RC GROUP SpA • General Catalogue• 155.EN.0504
CHAR
ACTE
RIST
ICSHousing made of galvanized steel sheet •
externally coated with PVC film
IDROCOMPL system •
Plate condenser •
Microprocessor control system •
Antifreeze system •
Circulating pump •
Water regulating valve •
Remote control board •
RS485 serial line card •
Spring antivibration holders •
Main switch •
OPTI
ONAL
AQUA.IDROCOMPL.W.NRM.Z2R407C • 23 ÷ 57 kW
The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.
SpaceSaverSPACE SAVER, components
internal layout allows all
inspection and maintenance
operations from the front of
the unit, with no use of side
spaces.
HIGH
LIGHT
S
Pump&PressureBuilt-in circulating pump with hydraulic plant pressure control,
all is managed by central microprocessor system.
242 RC GROUP SpA • General Catalogue• 155.EN.0504
COLDPAK.W.NRM - MODELCooling capacity (1) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgNoise pressure level (2) dB(A)
COLDPAK.W.NRM - MODELCooling capacity (1) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgNoise pressure level (2) dB(A)
T.50.Z2 T.55.Z2 T.68.Z2 T.84.Z249,2 56,6 72,8 85,4
2 2 2 21 1 1 1
695 695 695 6951200 1200 1200 12001500 1500 1500 1500465 465 490 61559 60 61 61
T.100.Z2 T.125.Z2 T.150.Z3 T.185.Z3112,5 138,4 170,2 208,9
2 2 3 31 1 1 1
795 795 895 8951200 1200 1800 18001700 1700 1700 1700720 740 990 102062 62,5 63,5 64
(1) Data referred to chilled water temperature 12/7°C; condenser inlet water at 30°C.(2) Noise pressure level 1m far from the unit in free field conditions.POWER SUPPLY: 400.3.50+N
Water cooled liquid chillersTE
CHNI
CAL D
ATA
IDEN
TIFIC
ATIO
N COLDPACK.W.NRMWater cooled packaged liquid chillers equipped with Scroll compressors and plate condenser.
COLDPACK, water cooled liquid chillers equipped with latest generation SCROLL compressors.
The use of SCROLL compressors in parallel connection allows increased energy efficiency in partial load operation,
representing approx. 70% of working hours of a liquid chiller in CRITICAL APPLICATION and 30% of the hours of a liquid
chiller in COMFORT applications.
243RC GROUP SpA • General Catalogue• 155.EN.0504
CHAR
ACTE
RIST
ICSHousing made of galvanized steel sheet •
externally coated with PVC film
Plate evaporator •
Plate condenser •
Microprocessor control system •
Antifreeze system •
Water flow control •
Pump-Down stop •
Door lock main switch •
Water regulating valve •
Remote control board •
Partial heat reclaim •
Mechanical flow switch •
Spring antivibration holders •
RS485 serial line •
UDT, SQL or ASME VIII Div.1 approvals •
OPTI
ONAL
COLDPACK.W.NRMR407C • 50 ÷ 210 kW
The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.
CoolingDensityPlusOptimization system of internal layout to achieve the best
ratio between occupied space and cooling capacity.HIGH
LIGHT
S
MP.ComThe new generation of RC microprocessors with AUTOADAPTIVE logic.
Self-adapting in real time to the actual operating parameters of the
system: such as water flow, plant inertia, outdoor air temperature
and presence of antifreeze solutions in the plant.
244 RC GROUP SpA • General Catalogue• 155.EN.0504
FRIGO.SCROLL.W.NRM “G” - MODELSizeCooling capacity (1) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgNoise pressure level (2) dB(A)
FRIGO.SCROLL.W.NRM “G” - MODELSizeCooling capacity (1) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgNoise pressure level (2) dB(A)
15.Z1 22.Z1 29.Z1 36.Z1 43.Z1 52.Z1 60.Z1 70.Z1G1 G1 G1 G1 G1 G1 G1 G1
15,2 22,1 31,4 37,2 43,6 52,3 57,6 68,81 1 1 1 1 1 1 11 1 1 1 1 1 1 1
620 620 620 620 620 620 620 620825 825 825 825 825 825 825 825
1400 1400 1400 1400 1400 1400 1400 1400200 200 240 240 260 260 300 30059 58 58 59 59 60 60 61
44.Z2 58.Z2 72.Z2 86.Z2 104.Z2 120.Z2 140.Z2G2 G2 G2 G2 G2 G2 G2
44,2 62,8 74,5 87,2 104,7 115,2 137,62 2 2 2 2 2 22 2 2 2 2 2 2
1200 1200 1200 1200 1200 1200 1200825 825 825 825 825 825 825
1400 1400 1400 1400 1400 1400 1400380 460 460 520 520 580 58060 60 61 61 62 62 63
(1) Data referred to chilled water temperature 12/7°C; condenser inlet water at 30°C.(2) Noise pressure level 1m far from the unit in free field conditions.POWER SUPPLY: 400.3.50+N
Water cooled liquid chillersTE
CHNI
CAL D
ATA
IDEN
TIFIC
ATIO
N FRIGO.SCROLL.W.NRM “G”Water cooled packaged liquid chillers equipped with Scroll compressors and plate condenser.
Reference size: “G”.
FRIGO, water cooled liquid chillers equipped with latest generation SCROLL compressors and plate heat exchangers.
All components are housed in a cabinet for reduced noise emission according to all strict current field norms.
The built-in SPACE SAVER function guarantees the possibility to carry out all inspection and maintenance operations from the
front of the unit, thus allowing the side by side installation of more units with high savings of occupied space.
245RC GROUP SpA • General Catalogue• 155.EN.0504
CHAR
ACTE
RIST
ICSHousing with aluminium profile frame •
with galvanized steel sheet panels
externally coated with PVC film
Plate evaporator •
Plate condenser •
Microprocessor control system •
Pump-Down stop •
Door lock main switch •
Water regulating valve •
Partial heat reclaim •
Mechanical flow switch •
Spring antivibration holders •
RS232C-RS422-RS485 serial line •
Outdoor air temperature sensor •
UDT, SQL or ASME VIII Div.1 approvals •
OPTI
ONAL
FRIGO.SCROLL.W.NRM “G”R407C • 15 ÷ 137 kW
The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.
ScrollThe state of the art in the field of medium/small size
compressors to grant excellent performances even in medium/
small plants.
SCROLL compressors grant a high reliability rate (MTBF),
which is an essential requirement for units dedicated to
industrial processes or CRITICAL applications.
HIGH
LIGHT
S
TR88Supervision and remote control system; up to 8 FRIGO can be supervised
in installations with fixed and variable flow rate.
Version available with R134a refrigerant chargesee page 274
246 RC GROUP SpA • General Catalogue• 155.EN.0504
FRIGO.RECIP.W.NRM “G” - MODELSizeCooling capacity (1) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgNoise pressure level (2) dB(A)
160.F2 204.F2 240.F2 286.F2 332.F2G3 G3 G4 G4 G4
151,5 193 226,1 269,2 3102 2 2 2 22 2 2 2 2
2700 2700 2900 2900 2900850 850 850 850 8501300 1300 1500 1500 15001130 1230 1500 1740 198082,5 79,5 83 83,4 86,5
(1) Data referred to chilled water temperature 12/7°C; condenser inlet water at 30°C.(2) Noise pressure level 1m far from the unit in free field conditions.POWER SUPPLY: 400.3.50+N
Water cooled liquid chillersTE
CHNI
CAL D
ATA
IDEN
TIFIC
ATIO
N FRIGO.RECIP.W.NRM “G”Water cooled packaged liquid chillers equipped with reciprocating compressors and shell and
tube condenser. Reference size: “G”.
FRIGO, water cooled liquid chillers equipped with high efficiency reciprocating compressors and cleanable shell and tube
heat exchangers.
The unit is designed around a frame allowing extraordinary maintenance operations, as for example the heat exchangers
or compressors change in an easy and fast way avoiding any dangerous operation for the unit. Everything is based on
EASY@SERVE logic, characteristic for all RC products range.
247RC GROUP SpA • General Catalogue• 155.EN.0504
CHAR
ACTE
RIST
ICSHousing made of epoxy painted •
galvanized steel sheet
Shell and tube evaporator •
Shell and tube condenser •
Microprocessor control system •
Pump-Down stop •
One capacity step each compressor •
Door lock main switch •
Water regulating valve •
Partial heat reclaim •
Part-Winding compressors •
starting system
Mechanical or electronic flow switch •
Rubber antivibration holders •
Compressors noise absorption cabinet •
RS232C-RS422-RS485 serial line •
Outdoor air temperature sensor •
UDT, SQL or ASME VIII Div.1 approvals •
OPTI
ONAL
FRIGO.RECIP.W.NRM “G”R407C • 150 ÷ 310 kW
The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.
MP99MP99 microprocessor control
system, with RC PROACTIVE
proprietary logic granting
continuous and safe operation in
any condition.
HIGH
LIGHT
S
FullHeatReclaim (FHR)All FRIGO models can be equipped with FULLHEATRECLAIM (FHR)
system for a total condensing heat reclaim, allowing
simultaneous production of chilled and hot water.
Version available with R134a refrigerant chargesee page 274
248 RC GROUP SpA • General Catalogue• 155.EN.0504
FRIGO.RECIP.W.NRM “S” - MODELCooling capacity (1) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgNoise pressure level (2) dB(A)
FRIGO.RECIP.W.NRM “S” - MODELCooling capacity (1) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgNoise pressure level (2) dB(A)
245.S1 370.S1 490.S1 640.S1 370.S2 430.S2 490.S2 550.S2 610.S2 675.S2 740.S2 860.S2 980.S2 1100.S2 1220.S2226,7 333,8 436 577,8 344,1 399,1 452 516,2 572,7 628,5 679,2 803,9 913,8 1042,4 1152,3
1 1 1 1 2 2 2 2 2 2 2 2 2 2 21 1 1 1 2 2 2 2 2 2 2 2 2 2 2
3000 3000 3000 3000 3550 3550 3550 3550 3550 3550 3550 3550 3550 3700 37001100 1100 1100 1100 1000 1000 1000 1000 1000 1000 1000 1300 1300 1300 13001980 1980 1980 1980 1850 1850 1850 1850 1850 1850 1850 2000 2000 2000 20001767 1910 2330 2518 2530 2700 2750 2880 2980 3100 3120 3480 3720 3900 400083 85 86 86 85 86 86 87 87 88 88 89 89 89 89
1350.S3 1470.S3 1590.S3 1710.S3 1830.S3 1960.S4 2080.S4 2200.S4 2320.S4 2440.S4 2940.S6 3180.S6 3420.S6 3660.S61254,5 1359,6 1500,1 1611 1718,8 1827,7 1955,5 2066,4 2196,9 2304,5 2719,2 3000,1 3222 3437,7
3 3 3 3 3 4 4 4 4 4 6 6 6 63 3 3 3 3 4 4 4 4 4 6 6 6 6
4890 4890 4890 4890 4890 3550 3550 3550 3700 3700 4890 4890 4890 48901430 1430 1550 1550 1550 2360 2360 2360 2360 2360 3100 3220 3220 32202150 2150 2000 2000 2000 1850 1850 1850 1850 1850 2150 2000 2000 21505200 5230 5520 5560 5600 7900 8100 8250 8350 8500 11520 12100 12390 1267090 90 90 90 90 91 91 91 91 91 91 91 92 92
(1) Data referred to chilled water temperature 12/7°C; condenser inlet water at 30°C.(2) Noise pressure level 1m far from the unit in free field conditions.POWER SUPPLY: 400.3.50
Water cooled liquid chillersTE
CHNI
CAL D
ATA
IDEN
TIFIC
ATIO
N FRIGO.RECIP.W.NRM “S”Water cooled packaged liquid chillers equipped with reciprocating compressors and shell and
tube condenser. Reference size: “S”.
FRIGO, water cooled liquid chillers equipped with industrial reciprocating compressors and cleanable shell and tube heat
exchangers.
The unit is designed for heavy duty service as process cooling in food industry, for example the fitted compressors are
designed and manufactured by RC Group. Some basic components like valves, are covered by international patents and are
specific for the latest generation of refrigerants and synthetic oils.
249RC GROUP SpA • General Catalogue• 155.EN.0504
CHAR
ACTE
RIST
ICSStructure in high thickness galvanized •
steel sheet protected with epoxy paint
Shell and tube evaporator •
Shell and tube condensers •
Microprocessor control system •
Pump-Down stop •
Part-Winding compressors •
starting system
One capacity step each compressor •
Door lock main switch •
Water regulating valve •
Partial heat reclaim •
Mechanical or electronic flow switch •
Rubber antivibration holders •
Compressors noise absorption cabinet •
RS232C-RS422-RS485 serial line •
Outdoor air temperature sensor •
UDT, SQL or ASME VIII Div.1 approvals •
OPTI
ONAL
FRIGO.RECIP.W.NRM “S”R407C • 232 ÷ 3440 kW
The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.
EMCAll RC products are in
compliance with the
norms about
electromagnetic
compatibility.
HIGH
LIGHT
S
CoolingDensityPlusOptimization of internal layout to achieve the best ratio between
footprint and cooling capacity.
Version available with R134a refrigerant chargesee page 274
250 RC GROUP SpA • General Catalogue• 155.EN.0504
FRIGO.SCREW.W.NRM - MODELCooling capacity (1) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgNoise pressure level (2) dB(A)
FRIGO.SCREW.W.NRM - MODELCooling capacity (1) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgNoise pressure level (2) dB(A)
130.V1 160.V1 180.V1 210.V1 240.V1 290.V1 360.V1 420.V1 470.V1 530.V1 580.V1 620.V1 680.V1130 163,2 178,9 202,7 241,6 291,2 351,9 413,4 464,2 513,6 571,8 609,5 703,91 1 1 1 1 1 1 1 1 1 1 1 11 1 1 1 1 1 1 1 1 1 1 1 1
2150 2150 2150 2150 2150 2150 2150 2150 2150 2150 2150 2150 2150900 900 900 900 900 900 900 900 900 900 900 900 9001950 1950 1950 1950 1950 1950 1950 1950 1950 1950 1950 1950 1950
79 79 79 79 80 80 80 80 81 81 81 82 82
260.V2 320.V2 360.V2 420.V2 480.V2 580.V2 720.V2 840.V2 940.V2 1060.V2 1160.V2 1240.V2 1360.V2258,1 326,4 357,7 404,6 481,5 582,6 704 826,9 935 1035,1 1144,5 1219,6 1403
2 2 2 2 2 2 2 2 2 2 2 2 22 2 2 2 2 2 2 2 2 2 2 2 2
3550 3550 3550 3550 3550 3550 3550 3550 3550 3550 3550 3550 35501000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 10001850 1850 1850 1850 1850 1850 1850 1850 1850 1850 1850 1850 1850
82 82 83 83 83 84 84 85 85 85 85 85 85
(1) Data referred to chilled water temperature 12/7°C; condenser inlet water at 30°C.(2) Noise pressure level 1m far from the unit in free field conditions.POWER SUPPLY: 400.3.50
Water cooled liquid chillersTE
CHNI
CAL D
ATA
IDEN
TIFIC
ATIO
N FRIGO.SCREW.W.NRMWater cooled packaged liquid chillers equipped with screw compressors and shell and tube
condenser.
FRIGO, water cooled liquid chillers equipped with screw compressors and cleanable shell and tube heat exchangers.
Units are equipped with MP99 microprocessor system with RC PROACTIVE proprietary logic to grant working continuity
even in emergency situations.
251RC GROUP SpA • General Catalogue• 155.EN.0504
CHAR
ACTE
RIST
ICSStructure in high thickness galvanized •
steel sheet protected with epoxy paint
Shell and tube evaporator •
Shell and tube condensers •
Microprocessor control system •
Pump-Down stop •
Star/Delta Starters compressors •
One capacity step each compressor •
Door lock main switch •
Water regulating valve •
Partial heat reclaim •
Mechanical or electronic flow switch •
Rubber antivibration holders •
Compressors noise absorption cabinet •
RS232C-RS422-RS485 serial line •
Outdoor air temperature sensor •
UDT, SQL or ASME VIII Div.1 approvals •
OPTI
ONAL
FRIGO.SCREW.W.NRM “V”R407C • 130 ÷ 1403 kW
The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.
ScrewHelical twin screw compressors with high efficiency, possibility
of proportional or multistep setting.HIGH
LIGHT
S
FullHeatReclaim (FHR)Integrated system for a total
condensing heat reclaim
allowing simultaneous
production of chilled and hot
water.
Version available with R134a refrigerant chargesee page 274
252 RC GROUP SpA • General Catalogue• 155.EN.0504
FRIGO.SCREW.W.NRM - MODELCooling capacity (1) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgNoise pressure level (2) dB(A)
FRIGO.SCREW.W.NRM - MODELCooling capacity (1) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgNoise pressure level (2) dB(A)
1410.V3 1590.V3 1740.V3 1860.V3 2040.V31397,7 1559,1 1724,7 1830,5 2100,2
3 3 3 3 33 3 3 3 3
4890 4890 4890 4890 48901430 1430 1430 1430 14302150 2150 2150 2150 2150
87 87 87 87 87
2220.V4 2320.V4 2480.V4 2720.V4 3180.V6 3480.V6 3700.V6 4080.V62070,2 2289,1 2439,2 2806 3118,5 34490,5 3661 4200,5
4 4 4 4 6 6 6 64 4 4 4 6 6 6 6
3550 3550 3550 3550 4890 4890 4890 48902360 2360 2360 2360 3200 3200 3200 32001850 1850 1850 1850 2150 2150 2150 2150
85 85 85 85 87 87 87 87
(1) Data referred to chilled water temperature 12/7°C; condenser inlet water at 30°C.(2) Noise pressure level 1m far from the unit in free field conditions.POWER SUPPLY: 400.3.50
Water cooled liquid chillersTE
CHNI
CAL D
ATA
IDEN
TIFIC
ATIO
N FRIGO.SCREW.W.NRMWater cooled packaged liquid chillers equipped with screw compressors and shell and tube
condenser.
FRIGO, water cooled liquid chillers equipped with screw compressors and cleanable shell and tube heat exchangers.
SCREW compressors and special NOISEBOX use allows the installation of the units in areas with a very strict noise
requirements.
NOISEBOX is designed to grant easy inspection of compressors.
253RC GROUP SpA • General Catalogue• 155.EN.0504
CHAR
ACTE
RIST
ICSStructure in high thickness galvanized •
steel sheet protected with epoxy paint
Shell and tube evaporator •
Shell and tube condensers •
Microprocessor control system •
Pump-Down stop •
Star/Delta Starters compressors •
One capacity step each compressor •
Door lock main switch •
Water regulating valve •
Partial heat reclaim •
Mechanical or electronic flow switch •
Rubber antivibration holders •
Compressors noise absorption cabinet •
RS232C-RS422-RS485 serial line •
Outdoor air temperature sensor •
UDT, SQL or ASME VIII Div.1 approvals •
OPTI
ONAL
FRIGO.SCREW.W.NRM “V”R407C • 1397 ÷ 4200 kW
The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.
AdaptiveRangeA wide range of models, versions and optional extras for any
kind of duty service applications in hi-tech. and comfort air
conditioning and industrial process cooling.
HIGH
LIGHT
S
CoolingDensityPlusThanks to COOLING DENSITY PLUS system, FRIGO SCREW range
achieves 4.200 kW cooling capacity in only 16 m2 granting a
Cooling Density (kW per m2 of plant space) of 268 kW/m2.
Version available with R134a refrigerant chargesee page 274
254 RC GROUP SpA • General Catalogue• 155.EN.0504
RC GROUP liquid chillers: wide range of units in terms of models, compressors and refrigerants.
EVAPORATING UNITSThis range of liquid chillers is equipped with Scroll or reciprocating compressors.Energy efficiency is one of the main features of all models; the wide range of accessories and versions allow multiple applications.
The air condensers to be matched are available with axial or centrifugal fans to allow the installation inside buildings with ducted airintake/discharge.The latest generation and high reliability microprocessor control system is equipped with RC PROACTIVE proprietary system and it issuitable for the connection with all main Building Management e Remote Monitoring systems available today on the market.
PLAN
T TY
PEIndoor Condenserless Chillers
255RC GROUP SpA • General Catalogue• 155.EN.0504
DIVI.IDROCOMPL.A.NRM.Z1 • R407C • 6 ÷ 17 kWIdrocompl condenserless chillers with scroll compressor.
DIVI.IDROCOMPL.A.NRM.Z2 • R407C • 21 ÷ 52 kWIdrocompl condenserless chillers with scroll compressors.
COLDPACK.A.NRM • R407C • 45 ÷ 197 kWCondenserless chillers with scroll compressors.
FRIGO.SCROLL.A.NRM “G” • R407C • 13 ÷ 118 kWCondenserless chillers with scroll compressors.
FRIGO.RECIP.A.NRM “G” • R407C • 132 ÷ 273 kWCondenserless chillers with reciprocating compressors.
FRIGO.RECIP.A.NRM “S” • R407C • 205 ÷ 3040 kWCondenserless chillers with reciprocating compressors.
256 INDOOR CONDENSERLESS CHILLERS
258
260
262
264
266
Indoor Condenserless ChillersIN
DEX
256 RC GROUP SpA • General Catalogue• 155.EN.0504
DIVI.IDROCOMPL.A.NRM.Z1 - MODELCooling capacity (1) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgNoise pressure level (2) dB(A)
DIVI.IDROCOMPL.A.NRM.Z1 - MODELCooling capacity (1) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgNoise pressure level (2) dB(A)
M.7.Z1 M.8.Z1 M.9.Z16,2 6,9 8,71 1 11 1 1
667 667 667497 497 497969 969 969120 120 12548 50 50
T.8.Z1 T.9.Z1 T.13.Z1 T.16.Z1 T.19.Z17 8,7 12,7 14,9 16,61 1 1 1 11 1 1 1 1
667 667 667 667 667497 497 497 497 497969 969 969 969 969120 125 135 140 15550 50 52 52 52
Data referred to coupling with remote air cooled condensers TEAM.MATE produced by RC GROUP.(1) Data referred to chilled water temperature 12/7°C; air to remote condenser at 35°C.(2) Noise pressure level 1m far from the unit in free field conditions.POWER SUPPLY: 230.1.50 for models “M” • 400.3.50+N for models “T”
Indoor Condenserless ChillersTE
CHNI
CAL D
ATA
IDEN
TIFIC
ATIO
N DIVI.IDROCOMPL.A.NRM.Z1Condenserless chillers equipped with Scroll compressor and Idrocompl system.
Matched to remote air cooled condenser.
NoFreezeAntifreeze system which totally preserves from the risks subsequent to water freezing inside
the evaporator.
257RC GROUP SpA • General Catalogue• 155.EN.0504
CHAR
ACTE
RIST
ICSHousing made of galvanized steel sheet •
externally coated with PVC film
IDROCOMPL system •
Microprocessor control system •
Rotalock stop valves on •
gas delivery and liquid return
Antifreeze system •
Remote air cooled condenser •
Circulating pump •
Remote control board •
RS485 serial line • OPTI
ONAL
The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.
DIVI.IDROCOMPL.A.NRM.Z1R407C • 6 ÷ 17 kW
HIGH
LIGHT
S
9
8
7
6
55
13
12
11
10
2 31 2 4
1. Water outlet2. Cooling circuits3. Magnesium anode4. Breather valve5. Temperature sensors6. Water pump (optional)7. Safety valve8. Water inlet9. Discharge tap10. Water tank11. Expansion tank12. Anticondensate insulation13. Gas/water heat exchanger
Idrocompl® system
Patent
Idrocompl®Patented system including evaporator, water tank and
expansion tank in a single component.
258 RC GROUP SpA • General Catalogue• 155.EN.0504
DIVI.IDROCOMPL.A.NRM.Z2 - MODELCooling capacity (1) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgNoise pressure level (2) dB(A)
DIVI.IDROCOMPL.A.NRM.Z2 - MODELCooling capacity (1) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgNoise pressure level (2) dB(A)
T.24.Z2 T.28.Z2 T.34.Z2 T.38.Z220,9 25,1 29,2 33,9
2 2 2 21 1 1 1
1342 1342 1342 1342497 497 497 497
1340 1340 1340 1340265 275 285 29554 54 54 54
T.42.Z2 T.50.Z2 T.58.Z237,3 46 51,9
2 2 21 1 1
1608 1608 1608708 708 708
1360 1360 1360462 485 49555 55 55
Data referred to coupling with remote air cooled condensers TEAM.MATE produced by RC GROUP.(1) Data referred to chilled water temperature 12/7°C; air to remote condenser at 35°C.(2) Noise pressure level 1m far from the unit in free field conditions.POWER SUPPLY: 400.3.50+N
Indoor Condenserless ChillersTE
CHNI
CAL D
ATA
IDEN
TIFIC
ATIO
N DIVI.IDROCOMPL.A.NRM.Z2Condenserless chillers equipped with Scroll compressors and Idrocompl system.
Matched to remote air cooled condenser.
SpaceSaverBuilt-in SPACE SAVER function grants the possibility to carry out all inspection and maintenance operations from the
front of the unit, allowing the side-by-side installation of more units with a high space saving.
259RC GROUP SpA • General Catalogue• 155.EN.0504
CHAR
ACTE
RIST
ICSHousing made of galvanized steel sheet •
externally coated with PVC film
IDROCOMPL system •
Microprocessor control system •
Rotalock stop valves on •
gas delivery and liquid return
Antifreeze system •
Remote air cooled condenser •
Circulating pump •
Remote control board •
RS485 serial line •
Rubber antivibration holders •
Main switch •
OPTI
ONAL
DIVI.IDROCOMPL.A.NRM.Z2R407C • 21 ÷ 52 kW
The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.
Made2LastHousing designed to last in time and in any weather condition:
flexible capillary pipes to avoid problems deriving from copper
work hardening; antivibration holders under the compressors to
reduce vibration transmission to the housing; galvanized steel
sheet parts; aluminium or stainless steel small parts.
HIGH
LIGHT
S
Easy@ServeAll components are
accessible through
handy frontal panels.
260 RC GROUP SpA • General Catalogue• 155.EN.0504
COLDPACK.A.NRM - MODELCooling capacity (1) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgNoise pressure level (2) dB(A)
COLDPACK.A.NRM - MODELCooling capacity (1) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgNoise pressure level (2) dB(A)
T.50.Z2 T.55.Z2 T.68.Z2 T.84.Z245,3 52 68 78,1
2 2 2 21 1 1 1
695 695 695 6951200 1200 1200 12001500 1500 1500 1500420 420 445 49059 60 61 61
T.100.Z2 T.125.Z2 T.150.Z3 T.185.Z3105,5 131,1 159,1 196,7
2 2 3 31 1 1 1
795 795 895 8951200 1200 1800 18001700 1700 1700 1700670 680 925 94062 62,5 63,5 64
Data referred to coupling with remote air cooled condensers TEAM.MATE produced by RC GROUP.(1) Data referred to chilled water temperature 12/7°C; air to remote condenser at 35°C.(2) Noise pressure level 1m far from the unit in free field conditions.POWER SUPPLY: 400.3.50+N
Indoor Condenserless ChillersTE
CHNI
CAL D
ATA
IDEN
TIFIC
ATIO
N COLDPACK.A.NRMCondenserless chillers equipped with Scroll compressors.
Matched to remote air cooled condenser.
COLDPACK: condenserless chiller equipped with SCROLL compressors; the most modern technology in the field of medium/
small compressors to grant excellent performances even in small/medium installations.
COLDPACK range is designed according to COOLING DENSITY PLUS logic for internal layout optimization, in order to guarantee
a better ratio between occupied space and supplied cooling capacity.
261RC GROUP SpA • General Catalogue• 155.EN.0504
CHAR
ACTE
RIST
ICSHousing made of galvanized steel sheet •
externally coated with PVC film
Plate evaporator •
Microprocessor control system •
Antifreeze system •
Water flow control •
Pump-Down stop •
Rotalock stop valves on •
gas delivery and liquid return
Door lock main switch •
Remote air cooled condenser •
Partial or total heat reclaim •
Mechanical flow switch •
Rubber antivibration holders •
RS485 serial line •
UDT, SQL or ASME VIII Div.1 approvals •
OPTI
ONAL
COLDPACK.A.NRMR407C • 45 ÷ 197 kW
The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.
AdaptiveRangeA wide range of models, optional extras and versions for
many applications, in comfort and hi-tech. air conditioning
systems.
HIGH
LIGHT
S
MP.ComThe new generation of RC microprocessors with AUTOADAPTIVE
logic. Self-adapting in real time to the actual operating parameters
of the system: such as water flow, plant inertia, outdoor air
temperature and presence of antifreeze solutions in the plant.
262 RC GROUP SpA • General Catalogue• 155.EN.0504
FRIGO.SCROLL.A.NRM “G” - MODELSizeCooling capacity (1) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgNoise pressure level (2) dB(A)
FRIGO.SCROLL.A.NRM “G” - MODELSizeCooling capacity (1) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgNoise pressure level (2) dB(A)
15.Z1 22.Z1 29.Z1 36.Z1 43.Z1 52.Z1 60.Z1 70.Z1G1 G1 G1 G1 G1 G1 G1 G1
13,3 18,5 26,4 31,8 37,4 42 51,2 59,11 1 1 1 1 1 1 11 1 1 1 1 1 1 1
620 620 620 620 620 620 620 620825 825 825 825 825 825 825 825
1400 1400 1400 1400 1400 1400 1400 1400190 190 230 230 240 240 270 27059 58 58 59 59 60 60 61
44.Z2 58.Z2 72.Z2 86.Z2 104.Z2 120.Z2 140.Z2G2 G2 G2 G2 G2 G2 G2
36,7 52,8 63,6 74,8 84,1 102,4 118,32 2 2 2 2 2 22 2 2 2 2 2 2
1200 1200 1200 1200 1200 1200 1200825 825 825 825 825 825 825
1400 1400 1400 1400 1400 1400 1400370 450 450 490 490 530 53060 60 61 61 62 62 63
Data referred to coupling with remote air cooled condensers TEAM.MATE produced by RC GROUP.(1) Data referred to chilled water temperature 12/7°C; air to remote condenser at 35°C.(2) Noise pressure level 1m far from the unit in free field conditions.POWER SUPPLY: 400.3.50+N
Indoor Condenserless ChillersTE
CHNI
CAL D
ATA
IDEN
TIFIC
ATIO
N FRIGO.SCROLL.A.NRM “G”Condenserless chillers equipped with Scroll compressors.
Matched to remote air cooled condenser.
FRIGO.A, condenserless chiller equipped with latest generation SCROLL compressors and plate heat exchangers. All
components are housed in a cabinet for reduced noise emission according to all strict current field norms.
The built-in SPACE SAVER function guarantees the possibility to carry out all inspection and maintenance operations from the
front of the unit, thus allowing the side by side installation of more units with high savings of occupied space.
263RC GROUP SpA • General Catalogue• 155.EN.0504
CHAR
ACTE
RIST
ICSHousing with aluminium profile frame •
with galvanized steel sheet panels
externally coated with PVC film
Plate evaporator •
Microprocessor control system •
Pump-Down stop •
Door lock main switch •
Remote air cooled condenser •
Partial or total heat reclaim •
Mechanical flow switch •
Rubber antivibration holders •
RS232C-RS422-RS485 serial line •
Outdoor air temperature sensor •
UDT, SQL or ASME VIII Div.1 approvals •
OPTI
ONAL
FRIGO.SCROLL.A.NRM “G”R407C • 13 ÷ 118 kW
The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.
CoolingDensityPlusOptimization of internal layout to achieve the best ratio
between footprint and cooling capacity.HIGH
LIGHT
S
EMCAll RC products are in compliance with the norms about
electromagnetic compatibility.
Version available with R134a refrigerant chargesee page 274
264 RC GROUP SpA • General Catalogue• 155.EN.0504
FRIGO.RECIP.A.NRM “G” - MODELSizeCooling capacity (1) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgNoise pressure level (2) dB(A)
160.F2 204.F2 240.F2 286.F2 332.F2G3 G3 G4 G4 G4
132,2 172,2 199,6 241,8 273,12 2 2 2 22 2 2 2 2
2700 2700 2900 2900 2900850 850 850 850 850
1300 1300 1500 1500 15001070 1080 1350 1560 171082,5 79,5 83 83,4 86,5
Data referred to coupling with remote air cooled condensers TEAM.MATE produced by RC GROUP.(1) Data referred to chilled water temperature 12/7°C; air to remote condenser at 35°C.(2) Noise pressure level 1m far from the unit in free field conditions.POWER SUPPLY: 400.3.50+N
Indoor Condenserless ChillersTE
CHNI
CAL D
ATA
IDEN
TIFIC
ATIO
N FRIGO.RECIP.A.NRM “G”Condenserless chillers equipped with reciprocating compressors.
Matched to remote air cooled condenser.
FRIGO.A, Condenserless chiller equipped with high efficiency reciprocating compressors and cleanable shell and tube heat
exchangers.
The unit is designed around a frame allowing extraordinary maintenance operations, as for example the heat exchangers
or compressors change in an easy and fast way avoiding any dangerous operation for the unit. Everything is based on
EASY@SERVE logic, characteristic for all RC products range.
265RC GROUP SpA • General Catalogue• 155.EN.0504
CHAR
ACTE
RIST
ICSHousing made of epoxy painted •
galvanized steel sheet
Shell and tube evaporator •
Microprocessor control system •
Pump-Down stop •
One capacity step each compressor •
Door lock main switch •
Remote air cooled condenser •
Partial or total heat reclaim •
Part-Winding compressors •
starting system
Mechanical or electric flow switch •
Rubber antivibration holders •
Compressors noise absorption cabinet •
RS232C-RS422-RS485 serial line •
Outdoor air temperature sensor •
UDT, SQL or ASME VIII Div.1 approvals •
OPTI
ONAL
FRIGO.RECIP.A.NRM “G”R407C • 132 ÷ 273 kW
The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.
MP99MP99 microprocessor control system, with RC PROACTIVE
proprietary logic granting continuous and safe operation in
any condition.HIGH
LIGHT
S
ZytelThe special compressor discharge pipes made of patented plastic
material avoid the breaking problems due to materials decay
(vibrations) typical of outdated copper pipelines and allow the fast
change of various pressure control components without any
refrigerant leak .
Version available with R134a refrigerant chargesee page 274
266 RC GROUP SpA • General Catalogue• 155.EN.0504
FRIGO.RECIP.A.RNM “S” - MODELCooling capacity (1) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgNoise pressure level (2) dB(A)
FRIGO.RECIP.A.RNM “S” - MODELCooling capacity (1) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgNoise pressure level (2) dB(A)
245.S1 370.S1 490.S1 640.S1 370.S2 430.S2 490.S2 550.S2 610.S2 675.S2 740.S2 860.S2 980.S2 1100.S2 1220.S2203,9 304,6 409,4 509,4 309,5 361,8 406,6 460,3 508,2 561,8 609,4 718,5 814,4 921,5 1017,4
1 1 1 1 2 2 2 2 2 2 2 2 2 2 21 1 1 1 2 2 2 2 2 2 2 2 2 2 2
3000 3000 3000 3000 3550 3550 3550 3550 3550 3550 3550 3550 3550 3700 37001100 1100 1100 1100 1000 1000 1000 1000 1000 1000 1000 1300 1300 1300 13001980 1980 1980 1980 1850 1850 1850 1850 1850 1850 1850 2000 2000 2000 20001655 1765 2065 2117 2440 2560 2560 2680 2760 2862 2876 3260 3420 3560 364083 85 86 86 85 86 86 87 87 88 88 89 89 89 89
1350.S3 1470.S3 1590.S3 1710.S3 1830.S3 1960.S4 2080.S4 2200.S4 2320.S4 2440.S4 2940.S6 3180.S6 3420.S6 3660.S61120,3 1215,2 1329,5 1425,3 1520,4 1628,7 1736 1831,7 1939,2 2034,8 2430,4 2658,9 2850,6 3040,9
3 3 3 3 3 4 4 4 4 4 6 6 6 63 3 3 3 3 4 4 4 4 4 6 6 6 6
4890 4890 4890 4890 4890 3550 3550 3550 3700 3700 4890 4890 4890 48901430 1430 1550 1550 1550 2360 2360 2360 2360 2360 3100 3220 3220 32202150 2150 2000 2000 2000 1850 1850 1850 1850 1850 2150 2000 2000 21504750 4690 4960 4990 5010 7140 7330 7460 7540 7670 10330 10870 11130 1137090 90 90 90 90 91 91 91 91 91 91 91 92 92
Data referred to coupling with remote air cooled condensers TEAM.MATE produced by RC GROUP.(1) Data referred to chilled water temperature 12/7°C; air to remote condenser at 35°C.(2) Noise pressure level 1m far from the unit in free field conditions.POWER SUPPLY: 400.3.50+N
Indoor Condenserless ChillersTE
CHNI
CAL D
ATA
IDEN
TIFIC
ATIO
N FRIGO.RECIP.A.NRM “S”Condenserless chillers equipped with reciprocating compressors.
Matched to remote air cooled condenser.
FRIGO, Condenserless chiller equipped with industrial reciprocating compressors and cleanable shell and tube heat
exchangers.
The unit is designed for heavy duty service as process cooling in food industry, for example the fitted compressors
are designed and manufactured by RC Group.
Some basic components, like valves, are covered by international patents and are specific for last generation of
refrigerants and synthetic oils.
267RC GROUP SpA • General Catalogue• 155.EN.0504
CHAR
ACTE
RIST
ICSStructure in high thickness galvanized •
steel sheet protected with epoxy paint
Shell and tube evaporator •
Microprocessor control system •
Pump-Down stop •
Part-Winding compressors •
starting system
One capacity step each compressor •
Door lock main switch •
Remote air cooled condenser •
Partial or total heat reclaim •
Mechanical or electric flow switch •
Rubber antivibration holders •
Compressors noise absorption cabinet •
RS232C-RS422-RS485 serial line •
Outdoor air temperature sensor •
UDT, SQL or ASME VIII Div.1 approvals •
OPTI
ONAL
FRIGO.RECIP.A.NRM “S”R407C • 205 ÷ 3040 kW
The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.
NoiseBoxNoise reduction system designed to grant the easy and
complete inspection of the compressors and associated
components.HIGH
LIGHT
S
TR88Supervision and remote control
system; up to 8 FRIGO can be
supervised in installation with
constant and variable flow rate.
Version available with R134a refrigerant chargesee page 274
268 RC GROUP SpA • General Catalogue• 155.EN.0504
RC GROUP liquid chillers: wide range of units in terms of models, compressors and refrigerants.
HEAT PUMP CONDENSERLESS CHILLERSThis range of liquid chillers uses Scroll compressors.All models are characterised by a high efficiency and can be customized thanks to a wide range of optional extras.
The air cooled condensers to be matched are available with axial or centrifugal fans to allow the units installation inside building withducted air intake/discharge.
PLAN
T TY
PEIndoor Heat Pump Condenserless Chillers
269RC GROUP SpA • General Catalogue• 155.EN.0504
DIVI.IDROCOMPL.A.P.NRM.Z1 • R407C • 6 ÷ 17 kWIdrocompl heat pump condenserless chillers with scroll compressor.
DIVI.IDROCOMPL.A.P.NRM.Z2 • R407C • 21 ÷ 52 kWIdrocompl heat pump condenserless chillers with scroll compressors.
270 HEAT PUMP EVAPORATING UNITS
272
Indoor Heat PumpCondenserless chillers
INDE
X
270 RC GROUP SpA • General Catalogue• 155.EN.0504
DIVI.IDROCOMPL.A.P.NRM.Z1 - MODELCooling capacity (1) kWHeating capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgNoise pressure level (3) dB(A)
DIVI.IDROCOMPL.A.P.NRM.Z1 - MODELCooling capacity (1) kWHeating capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgNoise pressure level (3) dB(A)
M.7.Z1 M.8.Z1 M.9.Z16,1 6,9 8,67 7,9 10,31 1 11 1 1
667 667 667497 497 497969 969 969123 123 12848 50 50
T.8.Z1 T.9.Z1 T.13.Z1 T.16.Z1 T.19.Z16,9 8,6 12,5 14,6 16,27,9 10,3 14,3 17 18,61 1 1 1 11 1 1 1 1
667 667 667 667 667497 497 497 497 497969 969 969 969 969123 128 139 144 15950 50 52 52 52
Data referred to coupling with remote air cooled condensers TEAM.MATE produced by RC GROUP.(1) Data referred to chilled water temperature 12/7°C; air to remote condenser at 35°C.(2) Data referred to hot water temperature 40/45°C; air to gas/air heat exchanger 7°C with 90%UR.(3) Noise pressure level 1m far from the unit in free field conditions.POWER SUPPLY: 230.1.50 for models “M” • 400.3.50+N for models “T”
Indoor Heat Pump Condenserless ChillersTE
CHNI
CAL D
ATA
IDEN
TIFIC
ATIO
N DIVI.IDROCOMPL.A.P.NRM.Z1Heat pump condenserless chillers equipped with Scroll compressor and Idrocompl system.
Matched to remote air cooled condenser.
AdaptiveRangeA wide range of models, optional extras and versions for application in hi-tech., hotels,
cinemas and shopping centres air conditioning systems.
271RC GROUP SpA • General Catalogue• 155.EN.0504
CHAR
ACTE
RIST
ICSHousing made of galvanized steel sheet •
externally coated with PVC film
IDROCOMPL system •
Cycle inversion valve •
Microprocessor control system •
Rotalock stop valves on •
gas delivery and liquid return
Antifreeze system •
Remote air cooled condenser •
Circulating pump •
Remote control board •
RS485 serial line • OPTI
ONAL
The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.
DIVI.IDROCOMPL.A.P.NRM.Z1R407C • 6 ÷ 17 kW
CoolingDensityPlusOptimization of internal layout to achieve the best
ratio between footprint and cooling capacity.
HIGH
LIGHT
S
Pump&PressurePUMP&PRESSURE kit consists of a built-in circulation pump and
of a water pressure control. Through this kit DIVI.IDROCOMPL.P
becomes a real heating station only needing electrical and
hydraulic connections to be 100% operating respecting all the
current norms.
272 RC GROUP SpA • General Catalogue• 155.EN.0504
DIVI.IDROCOMPL.A.P.NRM.Z2 - MODELCooling capacity (1) kWHeating capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgNoise pressure level (3) dB(A)
DIVI.IDROCOMPL.A.P.NRM.Z2 - MODELCooling capacity (1) kWHeating capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgNoise pressure level (3) dB(A)
T.24.Z2 T.28.Z2 T.34.Z2 T.38.Z220,6 24,5 28,4 32,623,5 28,3 33 37,5
2 2 2 21 1 1 1
1342 1342 1342 1342497 497 497 497
1340 1340 1340 1340275 285 295 30554 54 54 54
T.42.Z2 T.50.Z2 T.58.Z236,9 45,3 50,941,9 51,5 57,4
2 2 21 1 1
1608 1608 1608708 708 708
1360 1360 1360477 500 51055 55 55
Indoor Heat Pump Condenserless ChillersTE
CHNI
CAL D
ATA
Data referred to coupling with remote air cooled condensers TEAM.MATE produced by RC GROUP.(1) Data referred to chilled water temperature 12/7°C; air to remote condenser at 35°C.(2) Data referred to hot water temperature 40/45°C; air to gas/air heat exchanger 7°C with 90%UR.(3) Noise pressure level 1m far from the unit in free field conditions.POWER SUPPLY: 230.1.50 for models “M” • 400.3.50+N for models “T”
IDEN
TIFIC
ATIO
N DIVI.IDROCOMPL.A.P.NRM.Z2Heat pump condenserless chillers equipped with Scroll compressors and Idrocompl system.
Matched to remote air cooled condenser.
DIVI.IDROCOMP.P, heat pump condenserless chillers equipped with latest generation Scroll compressors and IDROCOMPL
integrated patented system.
IDROCOMPL system includes also NOFREEZE system which totally preserves from the risks subsequent to water freezing inside
the evaporator.
273RC GROUP SpA • General Catalogue• 155.EN.0504
CHAR
ACTE
RIST
ICSHousing made of galvanized steel sheet •
externally coated with PVC film
IDROCOMPL system •
Cycle inversion valve •
Microprocessor control system •
Rotalock stop valves on •
gas delivery and liquid return
Antifreeze system •
Remote air cooled condenser •
Circulating pump •
Remote control board •
RS485 serial line •
Rubber antivibration holders •
Main switch •
OPTI
ONAL
DIVI.IDROCOMPL.A.P.NRM.Z2R407C • 20 ÷ 51 kW
The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.
Made2LastHousing designed to last in time and in any weather condition: ZYTEL
flexible capillary pipes to avoid problems deriving from copper
work hardening; antivibration holders under the compressors to
reduce vibration transmission to the housing; galvanized steel
sheet parts; aluminium or stainless steel small parts.
HIGH
LIGHT
S
SpaceSaverPossibility to carry out all
inspection and maintenance
operations from the front of the
unit, SPACE SAVER allows units
side-by-side installation with high
savings of space.
274 RC GROUP SpA • General Catalogue• 155.EN.0504
R134a refrigerant is a HFC (hydrofluorocarbon) gas,
without Clhoride.
It is classified as a green gas with the lowest environmental
impact having an ozone depletion potential (ODP) equals to
zero; moreover it is not toxic, it is not flammable and has a
very low GWP (Greenhouse Warming Potential) index.
R134a is a pure refrigerant gas having characteristics
making it different from all azeotropic mixtures: pressure
and temperature remain unchanged during its status
changes; from liquid status to vapour and vice versa.
Door lock main switch•
It is also classified as low pressure refrigerant gas because
comparing it with R407c, at the same temperature the
pressure is definitively lower. For example at a temperature
of 50°C corresponds a pressure of 13,2 bar for R134a
against 20 bar for R407C.
For the above reasons R134a represents the solution
granting the most proper operation in installations with
high condensing temperatures.
RC GROUP liquid chillers range with R134a refrigerant
charge is very wide in terms of both units types and used
compressors.
In particular SCREW versions are equipped with high
efficiency twin screw compressors, specifically designed
to work with this refrigerant.
RC GROUP R134a liquid chillers have the same manufacturing
characteristics, optional list and microprocessor control
system as R407C units.
Liquid chillers with R134a
275RC GROUP SpA • General Catalogue• 155.EN.0504
Liquid chillers with R134a
AIR COOLED LIQUID CHILLERS
Axial fans
UNICO.SCROLL.A.STD / ELN
UNICO.RECIP.A.STD / ELN
UNICO.SCREW.A.STD / ELN
MODULO.RECIP.A.STD
Centrifugal fans
UNICO.SCROLL.C.STD / ELN
UNICO.RECIP.C.STD / ELN
FREE-COOLING AIR COOLED LIQUID CHILLERS
Axial fans
MAXIMO.SCROLL.A.STD / ELN
MAXIMO.RECIP.A.STD / ELN
MAXIMO.SCREW.A.STD / ELN
Centrifugal fans
MAXIMO.SCROLL.C.STD / ELN
MAXIMO.RECIP.C.STD / ELN
WATER COOLED LIQUID CHILLERS
FRIGO.SCROLL.W.NRM
FRIGO.RECIP.W.NRM
FRIGO.SCREW.W.NRM
CONDENSERLESS LIQUID CHILLERS
FRIGO.SCROLL.A.NRM
FRIGO.RECIP.A.NRM
FRIGO.SCREW.A.NRM
The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.
It is important to specify that these chillers components are different
from the ones of R407C units, so, comparing the two same models, you
can notice a different size, in particular with reference to air cooled
units.
For obvious space reasons we did not include the chapter related to
these units in this catalogue.
R134a liquid chillers catalogue is available only in electronic format (PDF)
and you can get it by requesting it to the RC GROUP Commercial Department
or by downloading it from company Internet site www.rcgroup.it.
276 RC GROUP SpA • General Catalogue• 155.EN.0504
New air cooled liquid chillers equipped with screw compressors.
AIR COOLED LIQUID CHILLERS EQUIPPED WITH SCREW COMPRESSORSAll models show a high energy efficiency and can be customized thanks to a wide range of optional extras including heat exchangersfor total or partial condensing heat reclaim.The latest generation and highly reliable microprocessor control system is equipped with RC PROACTIVE proprietary system and
it is designed to be connected to the main Building Management and Remote Monitoring systems available on the market.
PLAN
T TY
PEAir cooled liquid chillers - R134a
277RC GROUP SpA • General Catalogue• 155.EN.0504
UNICO.SCREW.A.FLX “U” • R407C • 450 ÷ 1050 kWLiquid chillers with screw compressors.
UNICO.SCREW.A.HEF “M” • R407C • 450 ÷ 1580 kWLiquid chillers with screw compressors.
UNICO.SCREW.A.XTR “U” • R407C • 460 ÷ 1100 kWLiquid chillers with screw compressors.
INDE
XAir cooled liquid chillers - R134a
278 AXIAL FANS
280
282
278 RC GROUP SpA • General Catalogue• 155.EN.0504
UNICO.SCREW.A.FLX “U” - MODELSizeCooling capacity (1) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgMean sound pressure level (2) dB(A)
450.V2 545.V2 620.V2 700.V2 780.V3 895.V3 1045.V3U9 U9 U10 U10 U12/11 U12/11 U13/12
452 544,4 620 697,7 780,3 895,3 1047,52 2 2 2 3 3 32 2 2 2 3 3 3
4510 4510 5500 5500 7480 7480 84702130 2130 2130 2130 2130 2130 21302430 2430 2430 2430 2430 2430 24304160 4850 5480 5340 6750 7970 837075 75 76 76 77 77 77
(1) Data referred to chilled water temperature at 12/7°C; condenser air inlet at 35°C.(2) Mean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 400.3.50+N
Air cooled liquid chillers with axial fans - R134aTE
CHNI
CAL D
ATA
UNICO.SCREW.A.FLX “U”Air cooled packaged liquid chillers equipped with screw compressors and axial fans.
Casing type: “U”.
IDEN
TIFIC
ATIO
N
FLX SeriesA range of highly FLeXible air-cooled chillers, to meet the most important requirements typical of modern
plants, with a good quality/price/performance ratio.
279RC GROUP SpA • General Catalogue• 155.EN.0504
CHAR
ACTE
RIST
ICSHousing with aluminium profile frame •
with galvanized steel sheet panels
externally coated with PVC film
Main components housed in a •
technical compartment separated
from the air flow
Shell and tube evaporator •
Microprocessor control system •
Step-step condensing control •
Pump-Down stop •
Step-step cooling capacity control •
Oil cooling system •
Star/delta compressors starting system •
Door lock main switch •
LNO Kit for about a 6 dB(A) noise •
pressure level reduction
Modulating condensing control •
Condensing control with Inverter •
Pumping group with 1 or 2 pumps •
Water tank •
Partial heat reclaim •
Mechanical or electronic flow switch •
Spring antivibration holders •
RS232C-RS422-RS485 serial line •
Outdoor air temperature sensor •
UDT, SQL or ASME VIII Div.1 approvals •
OPTI
ONAL
UNICO.SCREW.A.FLX “U”R134a • 450 ÷ 1050 kW
The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.
HIGH
LIGHT
S
PumpStationA complete built-in pumping station
(without size increase), equipped
with instruments and safety
devices totally integrated with the
unit control system in order to
emphasize the RC PROACTIVE
system; possibility to integrate
PumpStation with water tank
without any increase in footprint.
Easy@ServAll components are accessible through handy hinged panels equipped
with antiwind lock, without removal of heavy noise deading boxes.
Made2LastHousing designed to last in time and in any weather condition:
flexible capillary pipes to avoid problems deriving from
copper work hardening; antivibration holders under the
compressors to reduce vibration transmission to the
housing; housing in anodized aluminium; galvanized steel
sheet parts; aluminium or stainless steel small parts.
280 RC GROUP SpA • General Catalogue• 155.EN.0504
UNICO.SCREW.A.HEF “M” - MODELSizeCooling capacity (1) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgMean sound pressure level (2) dB(A)
UNICO.SCREW.A.HEF “M” - MODELSizeCooling capacity (1) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgMean sound pressure level (2) dB(A)
450.V2 500.V2 580.V2 630.V2 680.V2 790.V2 860.V3M15 M15 M161 M16 M16 M17 M18450,4 502,2 582,1 628,9 681,8 790,8 863,4
2 2 2 2 2 2 32 2 2 2 2 2 3
3930 3930 5000 5000 5000 6070 74202350 2350 2350 2350 2350 2350 23502510 2510 2510 2510 2510 2510 25104650 4700 5210 5880 6020 6500 731081 81 81 82 82 82 83
930.V3 1000.V3 1160.V3 1260.V4 1360.V4 1480.V4 1580.V4M18 M18 M19 M20 M20 M21 M22934 1001 1159,5 1257,7 1363,6 1474,9 1581,53 3 3 4 4 4 43 3 3 4 4 4 4
7420 7420 8490 9560 9560 10630 117002350 2350 2350 2350 2350 2350 23502510 2510 2510 2510 2510 2510 25108320 8530 9090 11000 11270 11750 1223083 83 84 84 84 84 84
(1) Data referred to chilled water temperature at 12/7°C; condenser air inlet at 35°C.(2) Mean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 400.3.50+N
Air cooled liquid chillers with axial fans - R134aTE
CHNI
CAL D
ATA
IDEN
TIFIC
ATIO
N UNICO.SCREW.A.HEF “M”Air cooled packaged liquid chillers equipped with screw compressors and axial fans.
Casing type “M”.
HEF SeriesIf the energy efficiency is your priority, the High EFficiency range has been designed to deliver
optimum values, among the highest available on today market.
281RC GROUP SpA • General Catalogue• 155.EN.0504
CHAR
ACTE
RIST
ICSHousing made of epoxy painted •
galvanized steel sheet
Shell and tube evaporator •
Microprocessor control system •
Step-step condensing control •
Pump-Down stop •
Step-step cooling capacity control •
Oil cooling system •
Star/delta compressors starting system •
Door lock main switch •
LNO Kit for about a 6 dB(A) noise •
pressure level reduction
Modulating condensing control •
Condensing control with Inverter •
Partial or total heat reclaim •
Mechanical or electronic flow switch •
Spring antivibration holders •
RS232C-RS422-RS485 serial line •
Outdoor air temperature sensor •
UDT, SQL or ASME VIII Div.1 approvals •
OPTI
ONAL
UNICO.SCREW.A.HEF “M”R134a • 450 ÷ 1580 kW
The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.
HIGH
LIGHT
S
ScrewHelical twin screw compressors
with high efficiency, possibility of
proportional or multistep setting,
designed for air cooled chillers
(high condensing temperatures).
FreezeProtectionEvaporator with built-in antifreeze heater and high thickness
insulation, combined with proprietary software for the
automatic start up of the pumping group with direct scanning
from the digital antifreeze sensor.
282 RC GROUP SpA • General Catalogue• 155.EN.0504
UNICO.SCREW.A.XTR “U” - MODELSizeCooling capacity (1) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgMean sound pressure level (2) dB(A)
450.V2 545.V2 620.V2 700.V2 780.V3 895.V3 1045.V3U9 U9 U10 U10 U12/11 U12/11 U13/12
452 544,4 620 697,7 780,3 895,3 1047,52 2 2 2 3 3 32 2 2 2 3 3 3
4510 4510 5500 5500 7480 7480 84702130 2130 2130 2130 2130 2130 21302430 2430 2430 2430 2430 2430 24304160 4850 5480 5340 6750 7970 837075 75 76 76 77 77 77
(1) Data referred to chilled water temperature at 12/7°C; condenser air inlet at 35°C.(2) Mean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 400.3.50+N
Air cooled liquid chillers with axial fans - R134aTE
CHNI
CAL D
ATA
IDEN
TIFIC
ATIO
N UNICO.SCREW.A.XTR “U”Air cooled packaged liquid chillers equipped with screw compressors and axial fans.
Casing type “U”.
XTR SeriesThis series has been designed to meet eXTReme requirements. Its sound levels are the lowest in this sector,
and thanks to an excellent efficiency, coupled with continuous operation up to an outside temperature of 56°C,
this series is a reference point in the segment of high-capacity chillers.
283RC GROUP SpA • General Catalogue• 155.EN.0504
CHAR
ACTE
RIST
ICSHousing with aluminium profile frame •
with galvanized steel sheet panels
externally coated with PVC film
Main components housed in a •
technical compartment separated
from the air flow
Shell and tube evaporator •
Microprocessor control system •
Modulating condensing control •
Pump-Down stop •
Step-step cooling capacity control •
Oil cooling system •
Star/delta compressors starting system •
Door lock main switch •
Condensing control with Inverter •
Pumping group with 1 or 2 pumps •
Water tank •
Partial or total heat reclaim •
Mechanical or electronic flow switch •
Spring antivibration holders •
RS232C-RS422-RS485 serial line •
Outdoor air temperature sensor •
UDT, SQL or ASME VIII Div.1 approvals •
OPTI
ONAL
UNICO.SCREW.A.XTR “U”R134a • 460 ÷ 1100 kW
The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.
HIGH
LIGHT
S
RCProactiveMicroprocessor control and monitoring
system technology owned by RC
PROACTIVE, designed to grant continuity of
work even in emergency situations.
AntirumbleRigid base frame made of a multiple
layer structure with high noise
absorption characteristics, to reduce
the noise emission from the bottom of
the unit.
It is an essential device in all those
installations where the units are
installed ”raised” from the floor
through distribution bars and/or
antivibration holders.
ServiceFastCompressors, electric
board and electronic
control system housed in
a technical compartment
separated from the air
flow to allow standard
maintenance with the unit
in operation.
284 RC GROUP SpA • General Catalogue• 155.EN.0504
New air cooled liquid chillers equipped with screw compressors.
FREE-COOLING LIQUID CHILLERSLiquid chillers with built-in indirect SRC free-cooling system are specifically designed to reduce energy consumption wherecooling energy is required even in wintertime and mid-season, as required in air conditioning systems for information technology,
communication and industrial cooling.The units are equipped with a combined system to use outdoor air for water free cooling or precooling.Thanks to a proprietary control logic developed by RC through a 30-year experience in production of these chillers, the energy savingachieved through this type of chillers is always the maximum allowed by the outdoor air temperature, without any compromise.These chillers are available also in OPTIMIZER version, internationally patented, able to multiply the energy savings achieved throughindirect free-cooling solutions specially in areas with a temperate climate.
PLAN
T TY
PEAir cooled free-cooling liquid chillers - R134a
285RC GROUP SpA • General Catalogue• 155.EN.0504
MAXIMO.SCREW.A.FLX “U” • R407C • 488 ÷ 1130 kWFree-cooling liquid chillers with screw compressors.
MAXIMO.SCREW.A.XTR “U” • R407C • 488 ÷ 1000 kWFree-cooling liquid chillers with screw compressors.
286 AXIAL FANS
288
Air cooled free-coolingliquid chillers - R134a
INDE
X
286 RC GROUP SpA • General Catalogue• 155.EN.0504
MAXIMO.SCREW.A.FLX “U” - MODELSizeCooling capacity (1) kWFree-Cooling capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgMean sound pressure level (3) dB(A)
440.V2 550.V2 610.V2 690.V2 765.V3 875.V3 1010.V3U9 U10 U10 U11 U12/11 U13/12 U14/13
488,9 617,2 679,6 775,5 855,8 979,4 1136,4290,7 392,7 392,5 493,7 493,4 587,8 688,6
2 2 2 2 3 3 32 2 2 2 3 3 3
4510 5500 5500 6490 7480 8470 94602385 2385 2385 2385 2385 2385 23852430 2430 2430 2430 2430 2430 24305060 6310 6470 7400 8690 9760 1085075 76 76 77 77 77 77
(1) Data referred to chilled water temperature at 15/10°C; outdoor air temperature at 35°C.(2) Data referred to inlet chilled water temperature at 15°C; outdoor air temperature at 2,5°C.(3) Mean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 400.3.50+N
Free-cooling liquid chillers with axial fans - R134aTE
CHNI
CAL D
ATA
IDEN
TIFIC
ATIO
N MAXIMO.SCREW.A.FLX “U”Air cooled packaged liquid chillers equipped with energy saving free-cooling SCR system, screw compressors
and axial fans. Casing type: “U”.
Serie FLXA range of highly FLeXible free-cooling chillers, to meet the most important requirements typical of modern
plants, with a good quality/price/performance ratio.
287RC GROUP SpA • General Catalogue• 155.EN.0504
CHAR
ACTE
RIST
ICSHousing with aluminium profile frame •
with galvanized steel sheet panels
externally coated with PVC film
Main components housed in a •
technical compartment separated
from the air flow
Shell and tube evaporator •
Free-cooling system •
Microprocessor control system •
Modulating condensing control •
coupled with flooding system
Pump-Down stop •
Star/delta compressors starting system •
Oil cooling system •
Step-step cooling capacity control •
Door lock main switch •
Optimizer system •
LNO Kit for about a 6 dB(A) noise •
pressure level reduction
Condensing control with Inverter •
coupled with flooding system
Pumping group with 1 or 2 pumps •
Water tank •
Partial heat reclaim •
Mechanical or electronic flow switch •
Spring antivibration holders •
RS232C-RS422-RS485 serial line •
UDT, SQL or ASME VIII Div.1 approvals •
OPTI
ONAL
MAXIMO.SCREW.A.FLX “U”R134a • 488 ÷ 1130 kW
The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.
HIGH
LIGHT
S
GlycolFreeThanks to a system of
exchangers set inside the unit,
the free-cooling circuit is 100%
protected from freezing
problems, while there is no
antifreeze in the building.
CoolingDensityPlusOptimization of internal layout to achieve the best ratio
between footprint and cooling capacity.
288 RC GROUP SpA • General Catalogue• 155.EN.0504
MAXIMO.SCREW.A.XTR “U” - MODELSizeCooling capacity (1) kWFree-Cooling capacity (2) kWCompressors n.Gas circuits n.Dimensions Length mm
Depth mmHeight mm
Net weight kgMean sound pressure level (3) dB(A)
465.V2 585.V2 640.V2 725.V2 815.V3 940.V3U10 U11 U11 U12 U14/13 U14/13
488,9 629,4 681,8 779,8 875,6 1006,2330,6 416,9 415,6 495,3 578 580,1
2 2 2 2 3 32 2 2 2 3 3
5500 6490 6490 7480 9460 94602385 2385 2385 2385 2385 23852430 2430 2430 2430 2430 24305600 7020 7110 8200 10260 1045063 64 64 64 65 65
(1) Data referred to chilled water temperature at 15/10°C; outdoor air temperature at 35°C.(2) Data referred to inlet chilled water temperature at 15°C; outdoor air temperature at 2,5°C.(3) Mean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 400.3.50+N
Free-cooling liquid chillers with axial fans - R134aTE
CHNI
CAL D
ATA
IDEN
TIFIC
ATIO
N MAXIMO.SCREW.A.XTR “U”Air cooled packaged liquid chillers equipped with energy saving free-cooling SCR system, screw compressors and
axial fans. Casing type: “U”.
Made2LastHousing designed to last in time and in bad weather: flexible capillary piping to avoid problems deriving from
copper work hardening; antivibration holders under the compressors to reduce vibration transmission to the
housing; electric cables in conduit and metallic cableways; housing in anodized aluminium; galvanized steel sheet
parts; aluminium or stainless steel small parts.
289RC GROUP SpA • General Catalogue• 155.EN.0504
CHAR
ACTE
RIST
ICSHousing with aluminium profile frame •
with galvanized steel sheet panels
externally coated with PVC film
Main components housed in a •
technical compartment separated
from the air flow
Shell and tube evaporator •
Free-cooling system •
Microprocessor control system •
Modulating condensing control •
coupled with flooding system
Pump-Down stop •
Star/delta compressors starting system •
Oil cooling system •
Step-step cooling capacity control •
Door lock main switch •
Optimizer system •
Condensing control with Inverter •
coupled with flooding system
Pumping group with 1 or 2 pumps •
Water tank •
Partial heat reclaim •
Mechanical or electronic flow switch •
Spring antivibration holders •
RS232C-RS422-RS485 serial line •
UDT, SQL or ASME VIII Div.1 approvals •
OPTI
ONAL
MAXIMO.SCREW.A.XTR “U”R134a • 488 ÷ 1000 kW
The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.
HIGH
LIGHT
S
RCProactiveMicroprocessor control and
monitoring system technology owned
by RC PROACTIVE, designed to grant
continuity of work even in emergency
situations.
SolutionMaximo Optimizer, in combination with our Heat Hunter
displacement air-conditioners series, form the Solution
proprietary system to optimise the energy saving in the presence
of variable flow-rate technological plants.
290 RC GROUP SpA • General Catalogue• 155.EN.0504
Air cooled condensers and dry coolers are specifically designed to work matched with RC GROUP air conditioning units and liquidchillers.They are available with axial or centrifugal fans to allow the installation in buildings with ducted air intake/discharge.The low noise versions offer working conditions with an extremely reduce noise pressure.
PLAN
T TY
PEAir cooled condensers and dry coolers
291RC GROUP SpA • General Catalogue• 155.EN.0504
Air cooled condensersDry coolers
AIR COOLED CONDENSERS
TEAM.MATE.DX.A • 8 ÷ 158 kWAir cooled condensers for outdoor installation.
TEAM.MATE.DX.A • 200 ÷ 610 kWAir cooled condensers for outdoor installation.
TEAM.MATE.DX.C • 8 ÷ 24 kWAir cooled condensers for indoor installation.
TEAM.MATE.DX.C.ELN • 12 ÷ 140 kWAir cooled condensers for indoor installation.
DRY COOLERS
TEAM.MATE.DC.A • 16 ÷ 113 kWDry coolers for outdoor installation.
TEAM.MATE.DC.A • 140 ÷ 600 kWDry coolers for outdoor installation.
TEAM.MATE.DC.C • 13 ÷ 120 kWDry coolers for indoor installation.
292 AXIAL FANS
294
296 CENTRIFUGAL FANS
298
300 AXIAL FANS
302
304 CENTRIFUGAL FANS
INDE
X
292 RC GROUP SpA • General Catalogue• 155.EN.0504
TEAM.MATE.DX.A - D - MODELNominal capacity (1) kWDimensions Length mm
Depth mmHeight mm
Net weight kgMean sound pressure level (2) dB(A)
TEAM.MATE.DX.A - L - MODELNominal capacity (1) kWDimensions Length mm
Depth mmHeight mm
Net weight kgMean sound pressure level (2) dB(A)
M.10D M.18D M.22D M.31D M.37D M.50D M.72D M.79D M.88D M.105D M.118D M.145D M.158D10,2 18,1 21,6 30,6 37,3 49,9 72,5 79 87,8 105,3 118,5 145,2 158,4850 850 1150 1350 1350 1550 2500 2500 3580 3580 3580 4660 4660482 482 482 620 620 620 630 630 630 630 630 630 630726 726 726 1026 1026 1026 1135 1135 1135 1135 1135 1135 113531 37 47 95 110 130 155 185 210 230 260 300 34055 57 56 65 65 64,2 67,2 67,2 68,5 68,5 68,5 67,5 67,5
M.10L M.18L M.22L M.31L M.37L M.50L M.72L M.79L M.88L M.105L M.118L M.145L M.158L8,3 13,6 16,5 24,3 28,6 38,8 56 58,9 70,8 82,7 88,3 111,9 118850 850 1150 1350 1350 1550 2500 2500 3580 3580 3580 4660 4660482 482 482 620 620 620 630 630 630 630 630 630 630726 726 726 1026 1026 1026 1135 1135 1135 1135 1135 1135 113531 37 47 95 110 130 155 185 210 230 260 300 340
47,3 49,3 48,3 57,3 57,3 56,5 59,5 59,5 60,8 60,8 60,8 59,8 59,8
(1) Data referred to condenser inlet air at 35°C, condensing temperature 50°C(2) Mean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 230.1.50
Air cooled condensers with axial fansTE
CHNI
CAL D
ATA
MyNoiseSolutions range (D or L) conceived to allow the selection directly from the catalogue of the most suitable product for
the specific legislative or environmental demands regarding the noise emission control.
This solution grants a highly valuable product from the energy point of view, with easy maintenance and a durability of
the results in time (noise deading materials decay).
TEAM.MATE.DX.AAir cooled condensers for outdoor installation equipped with axial fans.
IDEN
TIFIC
ATIO
N
293RC GROUP SpA • General Catalogue• 155.EN.0504
CHAR
ACTE
RIST
ICSHorizontal air flow •
Housing made of externally epoxy •
painted galvanized steel sheet
RIV1200 speed regulator for •
modulating condensing control
Stop valves on cooling connections •
Supporting legs for vertical •
air flow versionOP
TION
AL
The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.
TEAM.MATE.DX.A8 ÷ 158 kW
Made2LastHousing suitable for outdoor installation and designed for long
operating life consisting of galvanized steel sheet parts and
aluminium or stainless steel small parts.
MateIntegrated condensing control
system for a stepless speed
modulation of condensers
fans.
HIGH
LIGHT
S
294 RC GROUP SpA • General Catalogue• 155.EN.0504
Air cooled condensers with axial fansTE
CHNI
CAL D
ATA TEAM.MATE.DX.A.STD - MODEL
Motor connectionNominal capacity (1) kWDimensions Length mm
Depth mmHeight mm
Net weight kgMean sound pressure level (2) dB(A)
TEAM.MATE.DX.A.ELN - MODELMotor connectionNominal capacity (1) kWDimensions Length mm
Depth mmHeight mm
Net weight kgMean sound pressure level (2) dB(A)
T.244D T.244L T.367D T.367L T.489D T.489L T.612D T.612L∆ Y ∆ Y ∆ Y ∆ Y
244,7 201,8 367,1 302,8 489,4 403,7 611,8 504,63240 3240 4740 4740 6240 6240 7740 77402345 2345 2345 2345 2345 2345 2345 23451385 1385 1385 1385 1385 1385 1385 1385740 740 1000 1000 1280 1280 1540 154075,2 69,2 76,5 70,5 75,5 69,5 77,4 71,4
T.244D T.244L T.367D T.367L T.489D T.489L T.612D T.612L∆ Y ∆ Y ∆ Y ∆ Y
209,8 173,2 314,7 259,8 419,5 346,4 524,4 4333240 3240 4740 4740 6240 6240 7740 77402345 2345 2345 2345 2345 2345 2345 23451385 1385 1385 1385 1385 1385 1385 1385740 740 1000 1000 1280 1280 1540 154072,2 66,2 73,5 67,5 72,5 66,5 74,4 68,4
(1) Data referred to condenser inlet air at 35°C, condensing temperature 50°C(2) Mean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 230.1.50
TEAM.MATE.DX.AAir cooled condensers for outdoor installation equipped with axial fans.
Made2LastHousing suitable for outdoor installation and designed for long operating life consisting of galvanized steel sheet parts and
aluminium or stainless steel small parts.
IDEN
TIFIC
ATIO
N
295RC GROUP SpA • General Catalogue• 155.EN.0504
CHAR
ACTE
RIST
ICSVertical air flow •
Stainless steel housing •
Stop valves on cooling connections •
One circuit breaker for each fan •
In alternative to circuit breakers •
a control electric box is available
with modulating or step-step
condensing control
OPTI
ONAL
The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.
TEAM.MATE.DX.A200 ÷ 610 kW
QuickStartPlug and play unit in full compliance with current norms.
Electrical and refrigerant connections only are requested for
start-up.
EMCAll RC products are in
compliance with the
norms about
electromagnetic
compatibility.
HIGH
LIGHT
S
296 RC GROUP SpA • General Catalogue• 155.EN.0504
TEAM.MATE.DX.C - D - MODELNominal capacity (1) kWDimensions Length mm
Depth mmHeight mm
Net weight kgMean sound pressure level (2) dB(A)
TEAM.MATE.DX.C - L - MODELNominal capacity (1) kWDimensions Length mm
Depth mmHeight mm
Net weight kgMean sound pressure level (2) dB(A)
M.11.D M.14.D M.16.D M.24.D11,2 13,9 15,4 24930 930 930 1270850 850 850 930
9690 690 690 97070 70 75 8563 65 65 63
M.11.L M.14.L M.16.L M.24.L8,7 11 12 18,4930 930 930 1270850 850 850 930
9690 690 690 97070 70 75 85
55,3 58,3 58,3 55,3
(1) Data referred to condenser inlet air at 35°C, condensing temperature 50°C(2) Mean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 230.1.50
Air cooled condensers with centrifugal fansTE
CHNI
CAL D
ATA
TEAM.MATE.DX.CAir cooled condensers for indoor installation equipped with centrifugal fans.
IDEN
TIFIC
ATIO
N
CentriCENTRI version, with centrifugal fans for indoor or ducted installation makes this product the ideal
solution for small areas air conditioning where outdoor installation is not possible due to space or
environmental problems.
297RC GROUP SpA • General Catalogue• 155.EN.0504
CHAR
ACTE
RIST
ICSHorizontal air flow •
Housing with aluminium profile frame •
with galvanized steel sheet panels
externally coated with PVC film
RIV1200 speed regulator for •
modulating condensing control
Stop valves on cooling connections •
Vertical air flow •OP
TION
AL
The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.
TEAM.MATE.DX.C8 ÷ 24 kW
Made2LastHousing suitable for outdoor installation and designed for
long operating life consisting of galvanized steel sheet
parts and aluminium or stainless steel small parts.
HIGH
LIGHT
S
MateIntegrated condensing control
system for a stepless speed
modulation of condensers fans.
298 RC GROUP SpA • General Catalogue• 155.EN.0504
TEAM.MATE.DX.C.STD - MODELNominal capacity (1) kWDimensions Length mm
Depth mmHeight mm
Net weight kgMean sound pressure level (2) dB(A)
TEAM.MATE.DX.C.ELN - MODELNominal capacity (1) kWDimensions Length mm
Depth mmHeight mm
Net weight kgMean sound pressure level (2) dB(A)
T.15 T.17 T.21 T.31 T.44 T.57 T.82 T.92 T.116 T.14014,3 17 21 31 44,2 57,3 82,5 92,3 116,1 140,9930 930 1050 1270 1550 1850 2200 2200 2700 2700850 850 930 930 1100 1100 1180 1180 1400 1500690 690 820 970 1040 1190 1230 1230 1540 175070 75 85 140 170 295 320 340 460 56066 68 63 70,5 76 72,7 77,2 78,2 81,2 83,2
T.15 T.17 T.21 T.31 T.44 T.57 T.82 T.92 T.116 T.14012,1 14,2 17,7 26 37,4 48,2 70,1 77,7 97,8 119,2930 930 1050 1270 1550 1850 2200 2200 2700 2700850 850 930 930 1100 1100 1180 1180 1400 1500690 690 820 970 1040 1190 1230 1230 1540 175070 75 85 140 170 295 320 340 460 56059 61,5 56 62 67 63,7 69,2 70,2 74,2 76,2
(1) Data referred to condenser inlet air at 35°C, condensing temperature 50°C(2) Mean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 230.1.50
Air cooled condensers with centrifugal fansTE
CHNI
CAL D
ATA
IDEN
TIFIC
ATIO
N TEAM.MATE.DX.CAir cooled condensers for indoor installation equipped with centrifugal fans.
AdaptiveRangeA wide range of models, for application in any air conditioning installation.
299RC GROUP SpA • General Catalogue• 155.EN.0504
CHAR
ACTE
RIST
ICSHorizontal air flow •
Housing with aluminium profile frame •
with galvanized steel sheet panels
externally coated with PVC film
Electric box •
Stop valves on cooling connections •
up to T.44 model included
Insulated panels (ELN version) •
Vertical air flow •
Stop valves on cooling connections •
from T.57 model
Modulating condensing control • OPTI
ONAL
The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.
TEAM.MATE.DX.C12 ÷ 140 kW
MyNoiseSolutions range (STD-ELN) conceived
to allow the selection directly from
the catalogue of the most suitable
product for the specific legislative
or environmental demands
regarding the noise emission
control.
HIGH
LIGHT
S
QuickStartPlug and play unit in full compliance
with current norms. Electrical and
refrigerant connections only are
requested for start-up.
300 RC GROUP SpA • General Catalogue• 155.EN.0504
TEAM.MATE.DC.A.STD - MODELNominal capacity (1) kWDimensions Length mm
Depth mmHeight mm
Net weight kgMean sound pressure level (2) dB(A)
TEAM.MATE.DC.A.ELN - MODELNominal capacity (1) kWDimensions Length mm
Depth mmHeight mm
Net weight kgMean sound pressure level (2) dB(A)
M.20 M.26 M.36 M.56 M.83 M.11320,4 26,4 35,7 56,1 82,6 113,51350 1350 1550 2500 3580 4660620 620 620 630 630 630
1026 1026 1026 1135 1135 113595 110 130 185 260 34065 65 64,2 67,2 68,5 67,5
M.20 M.26 M.36 M.56 M.83 M.11316,8 21,4 29,1 45,6 67,9 92,31350 1350 1550 2500 3580 4660620 620 620 630 630 630
1026 1026 1026 1135 1135 113595 110 130 185 260 34057 57 55,2 59,2 60,5 59,5
(1) Data referred to inlet water temperature at 45°C; outdoor air temperature 35°C.(2) Mean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 230.1.50
Dry coolers with axial fansTE
CHNI
CAL D
ATA
TEAM.MATE.DC.ADry coolers for outdoor installation equipped with axial fans.
IDEN
TIFIC
ATIO
N
MyNoiseSolutions range conceived to allow the selection directly from the catalogue of the most suitable product for the
specific legislative or environmental demands regarding the noise emission control.
This solution grants a highly valuable product from the energy point of view, with easy maintenance and a durability of
the results in time (noise deading materials decay).
301RC GROUP SpA • General Catalogue• 155.EN.0504
CHAR
ACTE
RIST
ICSHorizontal air flow •
Housing made of externally epoxy •
painted galvanized steel sheet
One circuit breaker for each fan •
up to M56 model included
Supporting legs for •
vertical air flow version
One circuit breaker for each fan •
from M83 model OPTI
ONAL
The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.
TEAM.MATE.DC.A16 ÷ 113 kW
AdaptiveRangeA wide range of models, for application in any air
conditioning installation.
Made2LastHousing suitable for outdoor installation and designed for long
operating life consisting of galvanized steel sheet parts and
aluminium or stainless steel small parts.
HIGH
LIGHT
S
302 RC GROUP SpA • General Catalogue• 155.EN.0504
TEAM.MATE.DC.A.STD - MODELMotor connectionNominal capacity (1) kWDimensions Length mm
Depth mmHeight mm
Net weight kgMean sound pressure level (2) dB(A)
TEAM.MATE.DC.A.ELN - MODELMotor connectionNominal capacity (1) kWDimensions Length mm
Depth mmHeight mm
Net weight kgMean sound pressure level (2) dB(A)
T.198D T.198L T.294D T.294L T.377D T.377L T.500D T.500L∆ Y ∆ Y ∆ Y ∆ Y
198,4 159,1 293,9 236,1 377 303,9 499,7 400,53315 3315 4815 4815 6315 6315 7815 78152345 2345 2345 2345 2345 2345 2345 23451385 1385 1385 1385 1385 1385 1385 1385840 840 1120 1120 1460 1460 1740 174072 66 74 68 73 67 74 68
T.198D T.198L T.294D T.294L T.377D T.377L T.500D T.500L∆ Y ∆ Y ∆ Y ∆ Y
166 138,2 245,9 205,3 316,8 264,9 418 347,83315 3315 4815 4815 6315 6315 7815 78152345 2345 2345 2345 2345 2345 2345 23451385 1385 1385 1385 1385 1385 1385 1385840 840 1120 1120 1460 1460 1740 174067 61 69 63 68 62 69 63
(1) Data referred to inlet water temperature at 45°C; outdoor air temperature 35°C.(2) Mean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 400.3.50
Dry coolers with axial fansTE
CHNI
CAL D
ATA
TEAM.MATE.DC.ADry coolers for outdoor installation equipped with axial fans.
EMCAll RC products are in compliance with the norms about electromagnetic compatibility.
IDEN
TIFIC
ATIO
N
303RC GROUP SpA • General Catalogue• 155.EN.0504
CHAR
ACTE
RIST
ICSVertical air flow •
Housing in stainless steel •
One circuit breaker for each fan •OP
TION
AL
The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.
TEAM.MATE.DC.A140 ÷ 500 kW
Made2LastHousing suitable for outdoor installation and
designed for long operating life consisting of
galvanized steel sheet parts and aluminium or
stainless steel small parts.
HIGH
LIGHT
S
FanSpeedIntegrated control system for stepless fans speed modulation.
304 RC GROUP SpA • General Catalogue• 155.EN.0504
TEAM.MATE.DC.C.STD - MODELNominal capacity (1) kWDimensions Length mm
Depth mmHeight mm
Net weight kgMean sound pressure level (2) dB(A)
TEAM.MATE.DC.C.ELN - MODELNominal capacity (1) kWDimensions Length mm
Depth mmHeight mm
Net weight kgMean sound pressure level (2) dB(A)
T.16 T.23 T.34 T.44 T.63 T.86 T.11916 23,5 34 44,3 63,4 86,7 119,2
1050 1270 1550 1850 2200 2700 2700930 930 1100 1100 1180 1400 1500820 970 1040 1190 1230 1450 175080 135 163 287 310 450 55063 70,5 76 72,7 77,2 81,2 83,2
T.16 T.23 T.34 T.44 T.63 T.86 T.11913,2 19,5 28,2 36,7 53 72,9 99,21050 1270 1550 1850 2200 2700 2700930 930 1100 1000 1180 1400 1500820 970 1040 1190 1230 1450 175080 135 163 287 310 450 55056 62 67 63,7 69,2 74,2 76,2
(1) Data referred to inlet water temperature at 45°C; outdoor air temperature 35°C.(2) Mean sound pressure level 1m far from the unit in free field conditions, according to ISO 3744 norm.POWER SUPPLY: 400.3.50
Dry coolers with centrifugal fansTE
CHNI
CAL D
ATA
CentriCENTRI version, with centrifugal fans for indoor or ducted installation makes this product
the ideal solution for small areas air conditioning where outdoor installation is not possible
due to space or environmental problems.
TEAM.MATE.DC.CDry coolers for indoor installation equipped with centrifugal fans.
IDEN
TIFIC
ATIO
N
305RC GROUP SpA • General Catalogue• 155.EN.0504
CHAR
ACTE
RIST
ICSHorizontal air flow •
Housing with aluminium profile frame •
with galvanized steel sheet panels
externally coated with PVC film
One circuit breaker for each fan •
up to T34 model included
Vertical air flow •
One circuit breaker for each fan •
from T44 model
OPTI
ONAL
The units are in compliance with EC 98/37, EC 89/336, EC 73/23, EC 97/23norms and subsequent modifications.RC GROUP is ISO 9001 certified.
TEAM.MATE.DC.C13 ÷ 120 kW
AdaptiveRangeA wide range of models, for application in any air conditioning
installation.HIGH
LIGHT
S
Made2LastHousing suitable for outdoor installation and designed for
long operating life consisting of galvanized steel sheet parts
and aluminium or stainless steel small parts.
RC GROUPw w w . r c g r o u p . i t
RC GROUP S.p.A. • Via Roma, 5 • 27010 Valle Salimbene (PV), Italy • e-mail: sales@rcgroup.it • Tel. +39 (0) 382 433 811 • Fax +39 (0) 382 587 148