View
221
Download
0
Category
Preview:
Citation preview
AF-600 FPTM
Fan & Pump Drive Quick GuideGuia rapidaKurzanleitungGuide rapideGuida rapida
130R0288 *MG14E16S*
DET-759A/S/D/F/I
GE
GE EnergyIndustrial Solutions
© Copyright GE Industrial Solutions 2011
GE imagination at work
@
Industrial Solutions (formerly Power Protection),a division of GE Energy, is a fi rst class Europeansupplier of low and medium voltage productsincluding wiring devices, residential andindustrial electrical distribution components,automation products, enclosures and switchboards. Demand for the company’s products comes from wholesalers, installers, panelboard builders, contractors, OEMs and utilities worldwide.
www.ge.com/ex/industrialsolutions
BelgiumGE Industrial BelgiumNieuwevaart 51B-9000 GentTel. +32 (0)9 265 21 11
FinlandGE Energy Industrial SolutionsKuortaneenkatu 2FI-00510 HelsinkiTel. +358 (0)10 394 3760
FranceGE Energy Industrial SolutionsParis Nord 213, rue de la PerdrixF-95958 Roissy CDG CédexTel. +33 (0)800 912 816
GermanyGE Energy Industrial SolutionsVor den Siebenburgen 2D-50676 KölnTel. +49 (0)221 16539 - 0
HungaryGE Hungary Kft .Vaci ut 81-83.H-1139 BudapestTel. +36 1 447 6050
South AfricaGE Energy Industrial SolutionsUnit 4, 130 Gazelle AvenueCorporate Park Midrand 1685P.O. Box 76672 Wendywood 2144 Tel. +27 11 238 3000
SpainGE Energy Industrial SolutionsP.I. Clot del Tufau, s/nE-08295 Sant Vicenç de CastelletTel. +34 900 993 625
United Arab EmiratesGE Energy Industrial Solutions1101, City Tower 2, Sheikh Zayed RoadP.O. Box 11549, DubaiTel. +971 43131202
United KingdomGE Energy Industrial SolutionsHoughton CentreSalthouse RoadBlackmillsNorthamptonNN4 7EXTel. +44 (0)800 587 1239
ItalyGE Energy Industrial SolutionsCentro Direzionale ColleoniVia Paracelso 16Palazzo Andromeda B1I-20041 Agrate Brianza (MB)Tel. +39 2 61 773 1
NetherlandsGE Energy Industrial SolutionsParallelweg 10Nl-7482 CA HaaksbergenTel. +31 (0)53 573 03 03
PolandGE Power ControlsUl. Odrowaza 1503-310 WarszawaTel. +48 22 519 76 00
PortugalGE Energy Industrial SolutionsRua Camilo Castelo Branco, 805Apartado 27704401-601 Vila Nova de GaiaTel. +351 22 374 60 00
RussiaGE Energy Industrial Solutions27/8, Electrozavodskaya streetMoscow, 107023Tel. +7 495 937 11 11
United States of AmericaGE Energy Industrial Solutions41 Woodford AvenuePlainville, CT 06062
1 Safety
WARNINGHIGH VOLTAGE!Frequency converters contain high voltage whenconnected to AC mains input power. Installation, start up,and maintenance should be performed by qualifiedpersonnel only. Failure to perform installation, start up, andmaintenance by qualified personnel could result in deathor serious injury.
High VoltageFrequency converters are connected to hazardous mainsvoltages. Extreme care should be taken to protect againstshock. Only trained personnel familiar with electronicequipment should install, start, or maintain this equipment.
WARNINGUNINTENDED START!When the drive is connected to AC mains, the motor maystart at any time. The drive, motor, and any drivenequipment must be in operational readiness. Failure to bein operational readiness when the drive is connected to ACmains could result in death, serious injury, equipment, orproperty damage.
Unintended StartWhen the drive is connected to the AC mains, the motormay be started by means of an external switch, a serial buscommand, an input reference signal, or a cleared faultcondition. Use appropriate cautions to guard against anunintended start.
WARNINGDISCHARGE TIME!Frequency converters contain DC link capacitors that canremain charged even when AC mains is disconnected. Toavoid electrical hazards, remove AC mains from the drivebefore doing any service or repair and wait the amount oftime specified in Table 1.1. Failure to wait the specifiedtime after power has been removed prior to doing serviceor repair on the unit could result in death or serious injury.
Voltage Power SizeMinimum WaitingTime
200-240 V0.75-3.7 kW 1-5 HP 4 minutes
5.5-45 kW 7.5-60 HP 15 minutes
380-480 V
0.75-7.5 kW 1-10 HP 4 minutes
11-90 kW 15-125 HP 15 minutes
110-250 kW150-350 HP
20 minutes
315-1000 kW
450-1350 HP40 minutes
Voltage Power SizeMinimum WaitingTime
525-600 V
0.75-7.5 kW 1-10 HP 4 minutes
11-90 kW 15-125 HP 15 minutes
110-315 kW
150-400 HP20 minutes
355-1000 kW
450-1350 HP30 minutes
525-690 V
11-75 kW15-125 HP
15 minutes
110-400 kW150-550 HP
20 minutes
400-1400 kW600-1900 HP
30 minutes
SymbolsThe following symbols are used in this manual.
WARNINGIndicates a potentially hazardous situation which, if notavoided, could result in death or serious injury.
CAUTIONIndicates a potentially hazardous situation which, if notavoided, may result in minor or moderate injury. It mayalso be used to alert against unsafe practices.
CAUTIONIndicates a situation that may result in equipment orproperty damage-only accidents.
NOTEIndicates highlighted information that should be observedin order to avoid mistakes or operate equipment at lessthan optimal performance.
Approvals
Safety AF-600 FP Quick Guide
DET-759A 1
1 1
2 Introduction
Illustration 2.1 Exploded View Unit Size 1X
1 Keypad 10 Motor output terminals 96 (U), 97 (V), 98 (W)
2 RS-485 serial bus connector (+68, -69) 11 Relay 1 (01, 02, 03)
3 Analog I/O connector 12 Relay 2 (04, 05, 06)
4 Keypad input plug 13 Brake (-81, +82) and load sharing (-88, +89) terminals
5 Analog switches (A53), (A54) 14 Mains input terminals 91 (L1), 92 (L2), 93 (L3)
6 Cable strain relief / PE ground 15 USB connector
7 Decoupling plate 16 Serial bus terminal switch
8 Grounding clamp (PE) 17 Digital I/O and 24 V power supply
9 Shielded cable grounding clamp and strain relief 18 Control cable cover plate
NOTEPlease consult AF-600 FP Operating Instructions for other unit sizes.
Introduction AF-600 FP Quick Guide
2 DET-759A
22
3 Installation
3.1 Installation Site Checklist
• The drive relies on the ambient air for cooling.Observe the limits on ambient air temperature foroptimal operation
• Ensure that the installation location has sufficientsupport strength to mount the drive
• Keep the drive interior free from dust and dirt.Ensure that the components stay as clean aspossible. In construction areas, provide aprotective covering. Optional IP54 (NEMA 12)enclosures may be necessary.
• Keep the manual, drawings, and diagramsaccessible for detailed installation and operationinstructions. It is important that the manual isavailable for equipment operators.
• Locate equipment as near to the motor aspossible. Keep motor cables as short as possible.Check the motor characteristics for actualtolerances. Do not exceed
• 1000 ft [300 m] for unshielded motorleads
• 500 ft [150 m] for shielded cable.
3.2 Drive and Motor Pre-installationChecklist
• Compare the model number of unit on thenameplate to what was ordered to verify theproper equipment
• Ensure each of the following are rated for thesame voltage:
Line power
Drive
Motor
• Ensure that drive output current rating is equal toor greater than motor full load current for peakmotor performance.
Motor size and drive power must matchfor proper overload protection.
If drive rating is less than motor, fullmotor output cannot be achieved.
3.3 Mechanical Installation
3.3.1 Cooling
• To provide cooling airflow, mount the unit to asolid flat surface or to the optional back plate.
• Top and bottom clearance for air cooling must beprovided. Generally, 100-225 mm (4-10in) isrequired.
• Improper mounting can result in over heatingand reduced performance
• Derating for temperatures starting between 40°(104° F) and 50° C (122° F) and elevation 1000 m(3300 ft) above sea level must be considered. Seethe Design Guide for detailed information.
Illustration 3.1 Top and Bottom Cooling Clearance
Installation AF-600 FP Quick Guide
DET-759A 3
3 3
Voltage Power Size Clearance a/b
200-240 V
0.25-3.7 kW 1/3-5 HP 100 mm/4 in
5.5-30 kW 7.5-40 HP 200 mm/8 in
>30 kW/40 HP 225 mm/10 in
380-480 V
0.37-7.5 kW 1/2-10 HP 100 mm/4 in
11-55 kW 15-75 HP 200 mm/8 in
>55 kW/75 HP 225 mm/10 in
525-600 V
0.37-7.5 kW 1/2-10 HP 100 mm/4 in
11-55 kW 15-75 HP 200 mm/8 in
>55 kW/75 HP 225 mm/10 in
525-690 V all 225 mm/10 in
Table 3.1 Minimum Airflow Clearance Requirements
3.3.2 Lifting
• Check the weight of the unit to determine a safelifting method
• Ensure that the lifting device is suitable for thetask
• If necessary, plan for a hoist, crane, or forklift withthe appropriate rating to move the unit
• For lifting, use hoist rings on the unit, whenprovided
3.3.3 Mounting
• Mount the unit vertically
• The drive allows side by side installation.
• Ensure that the strength of the mounting locationwill support the unit weight
• Mount the unit to a solid flat surface or to theoptional backplate to provide cooling airflow (seeIllustration 3.2 and Illustration 3.3).
• Improper mounting can result in overheating andreduced performance.
• Use the slotted mounting holes on the unit forwall mounting, when provided.
Illustration 3.2 Proper Mounting with Backplate
Item A is a backplate properly installed for required airflowto cool the unit.
Illustration 3.3 Proper Mounting with Railings
NOTEBackplate is needed when mounted on railings.
Installation AF-600 FP Quick Guide
4 DET-759A
33
3.4 Electrical Installation
This section contains detailed instructions for wiring the drive. The following tasks are described.
• Wiring the motor to the drive output terminals
• Wiring the AC line power to the drive input terminals
• Connecting control and serial communication wiring
• After power has been applied, checking input and motor power; programming control terminals for their intendedfunctions
Illustration 3.4 shows a basic electrical connection.
Illustration 3.4 Basic Wiring Schematic Drawing.
Installation AF-600 FP Quick Guide
DET-759A 5
3 3
3.4.1 Requirements
WARNINGEQUIPMENT HAZARD!Rotating shafts and electrical equipment can be hazardous.All electrical work must conform to national and localelectrical codes. It is strongly recommended that instal-lation, start up, and maintenance be performed only bytrained and qualified personnel. Failure to follow theseguidelines could result in death or serious injury.
CAUTIONWIRING ISOLATION!Run input power, motor wiring and control wiring in threeseparate metallic conduits or use separated shielded cablefor high frequency noise isolation. Failure to isolate power,motor and control wiring could result in less thanoptimum drive and associated equipment performance.
For your safety, comply with the following requirements.
• Electronic controls equipment is connected tohazardous mains voltage. Extreme care should betaken to protect against electrical hazards whenapplying power to the unit.
• Run motor cables from multiple frequencyconverters separately. Induced voltage fromoutput motor cables run together can chargeequipment capacitors even with the equipmentturned off and locked out.
Overload and Equipment Protection
• An electronically activated function within thedrive provides overload protection for the motor.The overload calculates the level of increase toactivate timing for the trip (controller outputstop) function. The higher the current draw, thequicker the trip response. The overload providesClass 20 motor protection. See 7 Warnings andAlarms for details on the trip function.
• Because the motor wiring carries high frequencycurrent, it is important that wiring for mains,motor power, and control are run separately. Usemetallic conduit or separated shielded wire.Failure to isolate power, motor, and controlwiring could result in less than optimumequipment performance.
• All frequency converters must be provided withshort-circuit and over-current protection. Inputfusing is required to provide this protection, seeIllustration 3.5. See maximum fuse ratings in8.2.2 CE Compliance and 8.2.3 Fuse Tables.
Illustration 3.5 Drive Fuses
Wire Type and Ratings
• All wiring must comply with local and nationalregulations regarding cross-section and ambienttemperature requirements.
• GE recommends that all power connections bemade with a minimum 75° C rated copper wire.
3.4.2 Earth (Grounding) Requirements
WARNINGGROUNDING HAZARD!For operator safety, it is important to ground the driveproperly in accordance with national and local electricalcodes as well as instructions contained within thisdocument. Ground currents are higher than 3,5 mA. Failureto ground the drive properly could result in death orserious injury.
NOTEIt is the responsibility of the user or certified electricalinstaller to ensure correct grounding (earthing) of theequipment in accordance with national and local electricalcodes and standards.
• Follow all local and national electrical codes toground electrical equipment properly
• Proper protective grounding for equipment withground currents higher than 3,5 mA must beestablished, see Leakage Current (>3,5 mA)
• A dedicatedground wire is required for inputpower, motor power and control wiring
• Use the clamps provided with the equipment forproper ground connections
• Do not ground one drive to another in a “daisychain” fashion
Installation AF-600 FP Quick Guide
6 DET-759A
33
• Keep the ground wire connections as short aspossible
• Using high-strand wire to reduce electrical noiseis recommended
• Follow motor manufacturer wiring requirements
3.4.2.1 Leakage Current (>3.5 mA)
Follow national and local codes regarding protectivegrounding of equipment with a leakage current > 3.5 mA.Drive technology implies high frequency switching at highpower. This will generate a leakage current in the groundconnection. A fault current in the drive at the outputpower terminals might contain a DC component which cancharge the filter capacitors and cause a transient groundcurrent. The ground leakage current depends on varioussystem configurations including RFI filtering, shieldedmotor cables, and drive power.
EN/IEC61800-5-1 (Power Drive System Product Standard)requires special care if the leakage current exceeds 3.5 mA.Grounding must be reinforced in one of the followingways:
• Ground wire of at least 0.0155 in2 [10 mm2]
• Two separate ground wires both complying withthe dimensioning rules
See EN 60364-5-54 § 543.7 for further information.
Using RCDsWhere residual current devices (RCDs), also known asground leakage circuit breakers (ELCBs), are used, complywith the following:
Use RCDs of type B only which are capable ofdetecting AC and DC currents
Use RCDs with an inrush delay to prevent faultsdue to transient ground currents
Dimension RCDs according to the system configu-ration and environmental considerations
3.4.2.2 Grounding Using Shielded Cable
Grounding clamps are provided for motor wiring (seeIllustration 3.6).
Illustration 3.6 Grounding with Shielded Cable
3.4.2.3 Grounding Using Conduit
CAUTIONGROUNDING HAZARD!Do not use conduit connected to the drive as areplacement for proper grounding. Ground currents arehigher than 3.5mA. Improper grounding can result inpersonal injury or electrical shorts.
Dedicated grounding clamps are provided (SeeIllustration 3.7).
Illustration 3.7 Grounding with Conduit
Installation AF-600 FP Quick Guide
DET-759A 7
3 3
Illustration 3.8 Motor, Mains and Earth Wiring for Frame Sizes 2Xand Above Using Shielded Cable
1. Use a wire stripper to remove the insulation forproper grounding.
2. Secure the grounding clamp to the strippedportion of the wire with the screws provided.
3. Secure the grounding wire to the groundingclamp provided.
3.4.3 Motor Connection
WARNINGINDUCED VOLTAGE!Run output motor cables from multiple frequencyconverters separately. Induced voltage from output motorcables run together can charge equipment capacitors evenwith the equipment turned off and locked out. Failure torun output motor cables separately could result in deathor serious injury.
• Comply with local and national electrical codesfor cable sizes, see 9.1.1 Cables
• Motor wiring knockouts or access panels areprovided at the base of IP55/Nema 12 and IP66 /Nema 4X Indoor unit
• Do not install power factor correction capacitorsbetween the drive and the motor
• Do not wire a starting or pole-changing devicebetween the drive and the motor
• Connect the 3-phase motor wiring to terminals96 (U), 97 (V), and 98 (W)
• Ground the cable in accordance with groundinginstructions provided
• Follow motor manufacturer wiring requirements
The three following illustrations represent mains input,motor, and earth grounding for basic frequency converters.Actual configurations vary with unit types and optionalequipment.
3.4.4 AC Mains Connection
• Size wiring based upon the input current of thedrive.
• Comply with local and national electrical codesfor cable sizes, see 9.1.1 Cables.
• Connect 3-phase AC input power wiring toterminals L1, L2, and L3.
• Input power will be connected to the mains inputterminals.
• Ground the cable in accordance with groundinginstructions provided in 3.4.2 Earth (Grounding)Requirements
• All frequency converters may be used with anisolated input source as well as with groundreference power lines. When supplied from anisolated mains source (IT mains or floating delta)or TT/TN-S mains with a grounded leg (groundeddelta), set SP-50 RFI Filter to OFF. When off, theinternal RFI filter capacitors between the chassisand the intermediate circuit are isolated to avoiddamage to the intermediate circuit and to reduceearth capacity currents in accordance with IEC61800-3.
3.4.5 Control Wiring
• Isolate control wiring from high powercomponents in the drive.
• If the drive is connected to a thermistor, for PELVisolation, optional thermistor control wiring mustbe reinforced/double insulated. A 24 V DC supplyvoltage is recommended.
3.4.5.1 Access
• Remove access coverplate with a screwdriver. SeeIllustration 3.9.
• Or remove front cover by loosening attachingscrews. See Illustration 3.10.Tightening torque for front cover is 2.0 Nm forunit size 15 and 2.2 Nm for unit sizes 2X and 3X.
Installation AF-600 FP Quick Guide
8 DET-759A
33
Illustration 3.9 Control Wiring Access for IP20/Open ChassisEnclosures
Illustration 3.10 Control Wiring Access for IP55/Nema 12 andIP66/Nema 4/4X Indoor
3.4.5.2 Control Terminal Types
Illustration 3.14 shows the removable drive connectors.Terminal functions and default settings are summarized inTable 3.2.
Illustration 3.11 Control Terminal Locations
• Connector 1 provides four programmable digitalinputs terminals, two additional digital terminalsprogrammable as either input or output, a 24 VDC terminal supply voltage, and a common foroptional customer supplied 24 V DC voltage
• Connector 2 terminals (+)68 and (-)69 are for anRS-485 serial communications connection
• Connector 3 provides two analog inputs, oneanalog output, 10 V DC supply voltage, andcommons for the inputs and output
• Connector 4 is a USB port available for use withthe
• Also provided are two Form C relay outputs thatare in various locations depending upon the driveconfiguration and size
• Some options available for ordering with the unitmay provide additional terminals. See the manualprovided with the equipment option.
See 8.1 General Technical Data for terminal ratings details.
Installation AF-600 FP Quick Guide
DET-759A 9
3 3
Terminal DescriptionDigital Inputs/Outputs
Terminal ParameterDefaultSetting Description
12, 13 - +24V DC 24V DC supplyvoltage. Maximumoutput current is200mA total for all24V loads. Useable fordigital inputs andexternal transducers.
18 E-01 [8] Start
Digital inputs.
19 E-02 [0] Nooperation
32 E-05 [0] Nooperation
33 E-06 [0] No
operation
27 E-03 [0] No
operation
Selectable for either
digital input oroutput. Default settingis input.
29 E-04 [14] JOG
20 - Common for digitalinputs and 0Vpotential for 24Vsupply.
Analog Inputs/Outputs
39 -
Common for analogoutput
42 AN-50 Speed 0 -
High Limit
Programmable analog
output. The analogsignal is 0–20mA or4–20mA at a
maximum of 500Ω50 - +10V DC 10V DC analog supply
voltage. 15mAmaximum commonlyused for potenti-ometer or thermistor.
53 AN-1# Reference Analog input.
Selectable for voltageor current. SwitchesA53 and A54 select
mA or V.
54 AN-2# Feedback
55 -
Common for analoginput
Serial Communication
61 -
Integrated RC filter forcable shield. ONLY forconnecting the shieldwhen experiencingEMC problems.
68 (+) O-3# RS-485 Interface. Acontrol card switch isprovided fortermination resistance.
69 (-) O-3#
Terminal DescriptionDigital Inputs/Outputs
Terminal ParameterDefaultSetting DescriptionRelays
01, 02, 03 E-24 [0] [0] Alarm Form C relay output.Usable for AC or DCvoltage and resistiveor inductive loads.
04, 05, 06 E-24 [1] [0] Running
Table 3.2 Terminal Description
3.4.5.3 Wiring to Control Terminals
Control terminal connectors can be unplugged from thedrive for ease of installation, as shown in Illustration 3.12.
Illustration 3.12 Unplugging Control Terminals
1. Open the contact by inserting a small screwdriverinto the slot above or below the contact, asshown in Illustration 3.13.
2. Insert the bared control wire into the contact.
3. Remove the screwdriver to fasten the control wireinto the contact.
4. Ensure the contact is firmly established and notloose. Loose control wiring can be the source ofequipment faults or less than optimal operation.
Illustration 3.13 Connecting Control Wiring
Installation AF-600 FP Quick Guide
10 DET-759A
33
3.4.5.4 Using Shielded Control Cables
Correct shieldingThe preferred method in most cases is to secure controland serial communication cables with shielding clampsprovided at both ends to ensure best possible highfrequency cable contact.
50/60Hz ground loopsWith very long control cables, ground loops may occur. Toeliminate ground loops, connect one end of the shield-to-ground with a 100nF capacitor (keeping leads short).
Avoid EMC noise on serial communicationTo eliminate low-frequency noise between adjustablefrequency drives, connect one end of the shield toterminal 61. This terminal is connected to ground via aninternal RC link. Use twisted-pair cables to reduceinterference between conductors.
3.4.5.5 Control Terminal Functions
Drive functions are commanded by receiving control inputsignals.
• Each terminal must be programmed for thefunction it will be supporting in the parametersassociated with that terminal. See Table 3.2 forterminals and associated parameters.
• It is important to confirm that the controlterminal is programmed for the correct function.
• The default terminal programming is intended toinitiate drive functioning in a typical operationalmode.
3.4.5.6 Terminal 53 and 54 Switches
• Analog input terminals 53 and 54 can selecteither voltage (0 to 10V) or current (0/4–20mA)input signals
• Remove power to the drive before changingswitch positions
• Set switches A53 and A54 to select the signaltype. U selects voltage, I selects current.
• The switches are accessible when the keypad hasbeen removed (see Illustration 3.14). Note thatsome option cards available for the unit maycover these switches and must be removed tochange switch settings. Always remove power tothe unit before removing option cards.
• Terminal 53 default is for a speed reference signalin open-loop set in DR-61 Terminal 53 SwitchSetting
• Terminal 54 default is for a feedback signal inclosed-loop set in DR-63 Terminal 54 SwitchSetting
130BT310.10
Illustration 3.14 Location of Terminals 53 and 54 Switches
Installation AF-600 FP Quick Guide
DET-759A 11
3 3
3.4.6 Serial Communication
Connect RS-485 serial communication wiring to terminals(+)68 and (-)69.
• Shielded serial communication cable isrecommended
• See 3.4.2 Earth (Grounding) Requirements forproper grounding
Illustration 3.15 Serial Communication Wiring Diagram
For basic serial communication set-up, select the following
1. Protocol type in O-30 Protocol.
2. Drive address in O-31 Address.
3. Baud rate in O-32 Drive Port Baud Rate.
• Four communication protocols are internal to thedrive. Follow the motor manufacturer wiringrequirements.
Drive profile
Modbus RTU
Metasys N2®
Apogee FLN®
• Functions can be programmed remotely usingthe protocol software and RS-485 connection orin parameter group O-## Options / Comms
• Selecting a specific communication protocolchanges various default parameter settings tomatch that protocol’s specifications along withmaking additional protocol-specific parametersavailable.
• Option cards which install into the drive areavailable to provide additional communicationprotocols. See the option-card documentation forinstallation and operation instructions
Installation AF-600 FP Quick Guide
12 DET-759A
33
4 Start Up and Functional Testing
4.1 Pre-start
4.1.1 Safety Inspection
WARNINGHIGH VOLTAGE!If input and output connections have been connectedimproperly, there is potential for high voltage on theseterminals. If power leads for multiple motors areimproperly run through the same conduit, there is apotential for leakage current to charge capacitors withinthe drive, even when disconnected from line power input.For initial start-up, make no assumptions about powercomponents. Follow pre-start procedures. Failure to followpre-start procedures could result in personal injury ordamage to equipment.
1. Input power to the unit must be OFF and lockedout. Do not rely on the drive disconnect switchesfor input power isolation.
2. Verify that there is no voltage on input terminalsL1 (91), L2 (92), and L3 (93), phase-to-phase andphase-to-ground,
3. Verify that there is no voltage on outputterminals 96 (U), 97 (V), and 98 (W), phase-to-phase and phase-to-ground.
4. Confirm continuity of the motor by measuringohm values on U-V (96-97), V-W (97-98), and W-U(98-96).
5. Check for proper grounding of the drive as wellas the motor.
6. Inspect the drive for loose connections onterminals.
7. Record the following motor nameplate data:power, voltage, frequency, full load current, andnominal speed. These values are needed toprogram motor nameplate data later.
8. Confirm that the supply voltage matches voltageof drive and motor.
Start Up and Functional Tes... AF-600 FP Quick Guide
DET-759A 13
4 4
4.1.2 Start-up Check List
CAUTIONBefore applying power to the unit, inspect the entire installation as detailed in Table 4.1. Check mark those items whencompleted.
Inspect for Description Auxiliary equipment • Look for auxiliary equipment, switches, disconnects, or input fuses/circuit
breakers that may reside on the input power side of the adjustable frequencydrive or output side to the motor. Ensure that they are ready for full speedoperation.
• Check function and installation of any sensors used for feedback to the drive.
• Remove power factor correction caps on motor(s), if present.
Cable routing • Ensure that input power, motor wiring, and control wiring are separated or inthree separate metallic conduits for high frequency noise isolation.
Control wiring • Check for broken or damaged wires and loose connections.
• Check that control wiring is isolated from power and motor wiring for noiseimmunity.
• Check the voltage source of the signals, if necessary.
• The use of shielded cable or twisted pair is recommended. Ensure that theshield is terminated correctly.
Cooling clearance • Measure to make sure that the top and bottom clearance is adequate toensure proper airflow for cooling.
EMC considerations • Check for proper installation regarding electromagnetic compatibility.
Environmental considerations • See equipment label for the maximum ambient operating temperature limits.
• Humidity levels must be 5%–95% non-condensing.
Fusing and circuit breakers • Check for proper fusing or circuit breakers.
• Check that all fuses are inserted firmly and in operational condition and that allcircuit breakers are in the open position.
Grounding • The unit requires a ground wire from its chassis to the building ground.
• Check for good ground connections that are tight and free of oxidation.
• Grounding to conduit or mounting the back panel to a metal surface is not asuitable ground.
Input and output power wiring • Check for loose connections.
• Check that motor and line power are in separate conduits or separatedshielded cables.
Panel interior • Inspect to ensure that the unit interior is free of dirt, metal chips, moisture, andcorrosion.
Switches • Ensure that all switch and disconnect settings are in the proper positions.
Vibration • Check that the unit is mounted solidly or that shock mounts are used, asnecessary.
• Check for an unusual amount of vibration.
Table 4.1 Start-up Check List
Start Up and Functional Tes... AF-600 FP Quick Guide
14 DET-759A
44
4.2 Applying Power to the Drive
WARNINGHIGH VOLTAGE!Adjustable frequency drives contain high voltage whenconnected to AC line power. Installation, startup andmaintenance should be performed by qualified personnelonly. Failure to perform installation, startup andmaintenance by qualified personnel could result in deathor serious injury.
WARNINGUNINTENDED START!When drive is connected to AC line power, the motor maystart at any time. The drive, motor, and any drivenequipment must be in operational readiness. Failure to bein operational readiness when the drive is connected to ACline power could result in death, serious injury, equipment,or property damage.
1. Confirm input voltage is balanced within 3%. Ifnot, correct input voltage imbalance beforeproceeding. Repeat procedure after voltagecorrection.
2. Ensure optional equipment wiring, if present,matches installation application.
3. Ensure that all operator devices are in the OFFposition. Panel doors closed or cover mounted.
4. Apply power to the unit. DO NOT start the driveat this time. For units with a disconnect switch,turn to the ON position to apply power to thedrive.
4.3 Basic Operational Programming
Drives require basic operational programming prior torunning for best performance. Basic operationalprogramming requires entering motor-nameplate data forthe motor being operated and the minimum andmaximum motor speeds. Enter data in accordance with thefollowing procedure. Parameter settings recommended areintended for start up and checkout purposes. Applicationsettings may vary.
Enter data with power ON, but prior to operating thedrive.
1. Press [Quick Menu] on the keypad.
2. Use the navigation keys to scroll to Quick Startand press [OK].
3. Select language and press [OK]. Then enter themotor data in parameters P-02, P-03, P-06, P-07,F-04 and F-05 (induction motors only, for PMmotors, skip these parameters for now). Theinformation can be found on the motornameplate. The entire quick menu is shown in
P-07 Motor Power [kW] or P-02 MotorPower [HP]
F-05 Motor Rated Voltage
F-04 Base Frequency
P-03 Motor Current
P-06 Base Speed
4. F-07 Accel Time 1 is recommended as 60 secondsfor fans or 10 seconds for pumps.
5. F-08 Decel Time 1 is recommended as 60 secondsfor fans or 10 seconds for pumps.
6. For F-10 enter Elec OL Trip 1 for Class 20overload protection. For further information,please see 3.4.1 Requirements
7. For F-16 Motor Speed Low Limit [Hz] enter theapplication requirements. If these values areunknown at this time, the following values arerecommended. These values will ensure initialdrive operation. However, take any precautionsnecessary to prevent equipment damage. Makesure that the recommended values are safe touse for functional testing before starting theequipment.
Fan = 20 Hz
Pump = 20 Hz
Compressor = 30 Hz
8. In F-15 Motor Speed High Limit [Hz] enter themotor frequency from F-04 Base Frequency.
This concludes the quick set-up procedure. Press [Status]to return to the operational display.
In P-04 Auto Tune select Reduced Auto Tune or Full AutoTune and follow on-screen instructions. See 4.4 Auto Tune
Start Up and Functional Tes... AF-600 FP Quick Guide
DET-759A 15
4 4
4.4 Auto Tune
Auto tune is a test procedure that measures the electricalcharacteristics of the motor to optimize compatibilitybetween the drive and the motor.
• The drive builds a mathematical model of themotor for regulating output motor current. Theprocedure also tests the input phase balance ofelectrical power. It compares the motor character-istics with the data entered in P-02, P-03, P-06,P-07, F-04 and F-05.
• It does not cause the motor to run or harm tothe motor
• Some motors may be unable to run the completeversion of the test. In that case, select ReducedAuto Tune
• If an output filter is connected to the motor,select Reduced Auto Tune
• If warnings or alarms occur, see 7 Warnings andAlarms
• Run this procedure on a cold motor for bestresults
4.5 Check Motor Rotation
Prior to running the drive, check the motor rotation. Themotor will run briefly at 5Hz or the minimum frequency setin F-16 Motor Speed Low Limit [Hz].
1. Press [Main Menu] twice on the keypad.
2. Enter Parameter Data Set and scroll to P-## MotorData and press [OK] to enter.
3. Scroll to P-08 Motor Rotation Check.
4. Press [OK].
5. Scroll to Enable.
The following text will appear: Note! Motor may run inwrong direction.
6. Press [OK].
7. Follow the on-screen instructions.
To change the direction of rotation, remove power to thedrive and wait for power to discharge. Reverse theconnection of any two of the three motor cables on themotor or drive side of the connection.
4.6 Local Control Test
CAUTIONMOTOR START!Ensure that the motor, system, and any attachedequipment is ready for start. It is the responsibility of theuser to ensure safe operation under any operationalcondition. Failure to ensure that the motor, system, andany attached equipment is ready for start could result inpersonal injury or equipment damage.
NOTEThe hand key on the keypad provides a local startcommand to the drive. The OFF key provides the stopfunction.When operating in local mode, the up and down arrowson the keypad increase and decrease the speed output ofthe drive. The left and right arrow keys move the displaycursor in the numeric display.
1. Press [Hand].
2. Accelerate the drive by pressing [] to full speed.Moving the cursor left of the decimal pointprovides quicker input changes.
3. Note any acceleration problems.
4. Press [OFF].
5. Note any deceleration problems.
If acceleration problems were encountered
• If warnings or alarms occur, see
• Check that motor data is entered correctly
• Increase the accel time in F-07 Accel Time 1
• Increase current limit in F-43 Current Limit
• Increase torque limit in F-40 Torque Limiter(Driving)
If deceleration problems were encountered
• If warnings or alarms occur, see
• Check that motor data is entered correctly
• Increase the decel time in F-08 Decel Time 1
See 7.1 Warning and Alarm Definitions for resetting thedrive after a trip.
NOTE4.1 Pre-start through 4.6 Local Control Test in this chapterconcludes the procedures for applying power to the drive,basic programming, set-up, and functional testing.
Start Up and Functional Tes... AF-600 FP Quick Guide
16 DET-759A
44
4.7 System Start Up
The procedure in this section requires user-wiring andapplication programming to be completed. is intended tohelp with this task. The following procedure isrecommended after application set-up by the user iscompleted.
CAUTIONMOTOR START!Ensure that the motor, system, and any attachedequipment is ready for start. It is the responsibility of theuser to ensure safe operation under any operationalcondition. Failure to ensure that the motor, system, andany attached equipment is ready for start could result inpersonal injury or equipment damage.
1. Press [Auto].
2. Ensure that external control functions areproperly wired to the drive and all programmingcompleted.
3. Apply an external run command.
4. Adjust the speed reference throughout the speedrange.
5. Remove the external run command.
6. Note any problems.
If warnings or alarms occur, see 7 Warnings and Alarms.
Start Up and Functional Tes... AF-600 FP Quick Guide
DET-759A 17
4 4
5 User Interface
5.1 Keypad
The keypad is the combined display and keys on the frontof the unit. The keypad is the user interface to theadjustable frequency drive.
The keypad has several user functions.
• Start, stop, and control speed when in localcontrol
• Display operational data, status, warnings andcautions
• Programming adjustable frequency drivefunctions
• Manually reset the adjustable frequency driveafter a fault when auto-reset is inactive
NOTEThe display contrast can be adjusted by pressing [STATUS]and the up/down key.
5.1.1 Keypad Layout
The keypad is divided into four functional groups (seeIllustration 5.1).
Illustration 5.1 Keypad
a. Display area.
b. Display menu keys for changing the display toshow status options, programming, or errormessage history.
c. Navigation keys for programming functions,moving the display cursor, and speed control inlocal operation. Also included are the statusindicator lights.
d. Operational mode keys and reset.
User Interface AF-600 FP Quick Guide
18 DET-759A
55
5.1.2 Setting Keypad Display Values
The display area is activated when the adjustablefrequency drive receives power from AC line voltage, a DCbus terminal, or an external 24 V supply.
The information displayed on the keypad can becustomized for user application.
• Each display readout has a parameter associatedwith it.
• Options are selected in the menu Keypad Set-up.
• Display 2 has an alternate larger display option.
• The adjustable frequency drive status at thebottom line of the display is generated automat-ically and is not selectable.
Display Parameter number Default setting
1.1 K-20 Motor RPMs
1.2 K-21 Motor current
1.3 K-22 Motor power (kW)
2 K-23 Motor frequency
3 K-24 Reference in percent
5.1.3 Display Menu Keys
Menu keys are used for menu access for parameter set-up,toggling through status display modes during normaloperation, and viewing fault log data.
Key FunctionStatus Press to show operational information.
• In Auto mode, press and hold to togglebetween status read-out displays
• Press repeatedly to scroll through eachstatus display.
• Press and hold [Status] plus [] or [] to
adjust the display brightness
• The symbol in the upper right corner of thedisplay shows the direction of motorrotation and which set-up is active. This isnot programmable.
Quick Menu Allows access to programming parameters for
initial set-up instructions and many detailedapplication instructions.
• Press to access Quick Start for sequenced
instructions to program the basic frequencycontroller set-up
• Press to access Fan Macros, Pump Macros,Compressor Macros, or Closed Loop forsequenced instructions to program
applications
• Press to access Trending for realtimelogging on keypad display.
• Press to access Parameter Data Check forchanges in parameter data set.
• Follow the sequence of parameters aspresented for the function set-up
Main Menu Allows access to all programming parameters.
• Press twice to access top-level index
• Press once to return to the last locationaccessed.
• Press and hold to enter a parameternumber for direct access to that parameter.
Alarm Log Displays a list of current warnings, the last 10alarms, and the maintenance log.
• For details about the drive before it enteredthe alarm mode, select the alarm numberusing the navigation keys and press [OK].
User Interface AF-600 FP Quick Guide
DET-759A 19
5 5
5.1.4 Navigation Keys
Navigation keys are used for programming functions andmoving the display cursor. The navigation keys alsoprovide speed control in local (hand) operation. Threedrive status indicator lights are also located in this area.
Key Function
Back Reverts to the previous step or list in the menustructure.
Cancel Cancels the last change or command as long as
the display mode has not changed.
Info Press for a definition of the function being
displayed.
NavigationKeys
Use the four navigation arrows to move betweenitems in the menu.
OK Use to access parameter groups or to enable achoice.
Light Indicator Function
Green ON The ON light activates when the
drive receives power from AC linevoltage, a DC bus terminal, or anexternal 24V supply.
Yellow WARN When warning conditions are met,the yellow WARN light comes onand text appears in the displayarea identifying the problem.
Red ALARM A fault condition causes the redalarm light to flash and an alarmtext is displayed.
5.1.5 Operation Keys
Operation keys are found at the bottom of the keypad.
Key Function
Hand Press to start the drive in local control.
• Use the navigation keys to control drivespeed
• An external stop signal by control input orserial communication overrides the local hand
Off Stops the motor but does not remove power tothe drive.
Auto Puts the system in remote operational mode.
• Responds to an external start command bycontrol terminals or serial communication
• Speed reference is from an external source
Reset Resets the drive manually after a fault has beencleared.
5.2 Backup and Copying Parameter Settings
Programming data is stored internally in the drive.
• The data can be uploaded into the keypadmemory as a storage backup
• Once stored in the keypad, the data can bedownloaded back into the drive
• Data can also be downloaded into otheradjustable frequency drives by connecting thekeypad into those units and downloading thestored settings. (This is a quick way to programmultiple units with the same settings.)
• Initialization of the drive to restore factory defaultsettings does not change data stored in thekeypad memory
WARNINGUNINTENDED START!When the drive is connected to AC line power, the motormay start at any time. The drive, motor, and any drivenequipment must be in operational readiness. Failure tocomply could result in death, serious injury, equipment orproperty damage.
User Interface AF-600 FP Quick Guide
20 DET-759A
55
5.2.1 Uploading Data to the keypad
1. Press [OFF] to stop the motor before uploadingor downloading data.
2. Go to K-50 Keypad Copy.
3. Press [OK].
4. Select All to keypad.
5. Press [OK]. A progress bar shows the uploadingprogress.
6. Press [Hand] or [Auto] to return to normaloperation.
5.2.2 Downloading Data from the keypad
1. Press [OFF] to stop the motor before uploadingor downloading data.
2. Go to K-50 Keypad Copy.
3. Press [OK].
4. Select All from keypad.
5. Press [OK]. A progress bar shows thedownloading process.
6. Press [Hand] or [Auto] to return to normaloperation.
5.3 Restoring Default Settings
CAUTIONInitialization restores the unit to factory default settings.Any programming, motor data, localization, andmonitoring records will be lost. Uploading data to thekeypad provides a backup prior to initialization.
Restoring the drive parameter settings back to defaultvalues is done by initialization of the adjustable frequencydrive. Initialization can be through H-03 Restore FactorySettings or manually.
• Initialization using H-03 Restore Factory Settingsdoes not change drive data such as operatinghours, serial communication selections, personalmenu settings, fault log, alarm log, and othermonitoring functions
• Using H-03 Restore Factory Settings is generallyrecommended.
• Manual initialization erases all motor,programming, localization, and monitoring dataand restores factory default settings.
5.3.1 Recommended Initialization
1. Press [Main Menu] twice to access parameters.
2. Scroll to H-03 Restore Factory Settings.
3. Press [OK].
4. Scroll to [2] Restore Factory Settings.
5. Press [OK].
6. Remove power to the unit and wait for thedisplay to turn off.
7. Apply power to the unit.
Default parameter settings are restored during start-up.This may take slightly longer than normal.
8. Alarm 80 is displayed.
9. Press [Reset] to return to operation mode.
5.3.2 Manual Initialization
1. Remove power to the unit and wait for thedisplay to turn off.
2. Press and hold [Status], [Main Menu], and [OK] atthe same time and apply power to the unit.
Factory default parameter settings are restored duringstartup. This may take slightly longer than normal.
Manual initialization does not reset the following driveinformation
• ID-00 Operating Hours
• ID-03 Power Up's
• ID-04 Over Temp's
• ID-05 Over Volt's
User Interface AF-600 FP Quick Guide
DET-759A 21
5 5
6.1.1 Main Menu StructureK-
## K
eypa
d S
et-u
pK-
37 D
ispl
ay T
ext
1K-
8# D
ays
and
Dat
e/Ti
me
Read
out
F-2#
Fun
dam
enta
l 2E-
## D
igita
l In/
Out
K-0#
Key
pad
Bas
ic S
ettin
gsK-
38 D
ispl
ay T
ext
2K-
81 W
orki
ng D
ays
F-24
Hol
ding
Tim
eE-
0# D
igita
l Inp
uts
K-01
Lan
guag
eK-
39 D
ispl
ay T
ext
3K-
82 A
dditi
onal
Wor
king
Day
sF-
26 M
otor
Noi
se (C
arrie
r Fr
eq)
E-00
Dig
ital I
/O M
ode
K-02
Mot
or S
peed
Uni
tK-
4# K
eypa
d B
utto
ns
K-83
Add
ition
al N
on-W
orki
ng
Day
sF-
27 M
otor
Ton
e Ra
ndom
E-01
Ter
min
al 1
8 D
igita
l Inp
ut
K-03
Reg
iona
l Set
tings
K-40
[Han
d] B
utto
n o
n K
eypa
dK-
89 D
ate
and
Tim
e Re
adou
tF-
3# F
unda
men
tal 3
E-02
Ter
min
al 1
9 D
igita
l Inp
ut
K-04
Ope
ratin
g S
tate
at
Pow
er-u
pK-
41 [O
ff] B
utto
n o
n K
eypa
dF-
## F
unda
men
tal P
ars
F-37
Adv
. Sw
itchi
ng P
atte
rnE-
03 T
erm
inal
27
Dig
ital I
nput
K-05
Loc
al M
ode
Uni
tK-
42 [A
uto]
But
ton
on
Key
pad
F-0#
Fun
dam
enta
l 0F-
38 O
verm
odul
atio
nE-
04 T
erm
inal
29
Dig
ital I
nput
K-1#
Key
pad
Set
-up
Ope
ratio
nsK-
43 [R
eset
] Bu
tton
on
Key
pad
F-01
Fre
quen
cy S
ettin
g 1
F-4#
Fun
dam
enta
l 4E-
05 T
erm
inal
32
Dig
ital I
nput
K-10
Act
ive
Set-
upK-
5# C
opy/
Save
F-02
Ope
ratio
n M
etho
dF-
40 T
orqu
e Li
mite
r (D
rivin
g)E-
06 T
erm
inal
33
Dig
ital I
nput
K-11
Edi
t Se
t-up
K-50
Key
pad
Cop
yF-
03 M
ax O
utpu
t Fr
eque
ncy
1F-
41 T
orqu
e Li
mite
r (B
raki
ng)
E-1#
Add
Acc
el/D
ecel
Ram
ps
K-12
Thi
s Se
t-up
Lin
ked
toK-
51 S
et-u
p C
opy
F-04
Bas
e Fr
eque
ncy
F-43
Cur
rent
Lim
itE-
10 A
ccel
Tim
e 2
K-13
Rea
dout
: Lin
ked
Set
-ups
K-6#
Pas
swor
d P
rote
ctio
nF-
05 M
otor
Rat
ed V
olta
geF-
5# E
xten
ded
Ref
eren
ces
E-11
Dec
el T
ime
2
K-14
Rea
dout
: Edi
t Se
t-up
s /
Chan
nel
K-60
Mai
n M
enu
Pas
swor
dF-
07 A
ccel
Tim
e 1
F-52
Min
imum
Ref
eren
ceE-
2# D
igita
l Out
puts
K-2#
Key
pad
Dis
play
K-61
Acc
ess
to M
ain
Men
u w
/o
Pass
wor
dF-
08 D
ecel
Tim
e 1
F-53
Max
imum
Ref
eren
ceE-
20 T
erm
inal
27
Dig
ital O
utpu
t
K-20
Dis
play
Lin
e 1.
1 Sm
all
K-65
Qui
ck M
enu
Pas
swor
dF-
1# F
unda
men
tal 1
F-54
Ref
eren
ce F
unct
ion
E-21
Ter
min
al 2
9 D
igita
l Out
put
K-21
Dis
play
Lin
e 1.
2 Sm
all
K-66
Acc
ess
to Q
uick
Men
u w
/oPa
ssw
ord
F-10
Ele
ctro
nic
Ove
rload
F-6#
Ref
eren
ces
E-24
Fun
ctio
n R
elay
K-22
Dis
play
Lin
e 1.
3 Sm
all
K-7#
Clo
ck S
ettin
gsF-
11 M
otor
Ext
erna
l Fan
F-64
Pre
set
Rela
tive
Refe
renc
eE-
26 O
n D
elay
, Rel
ay
K-23
Dis
play
Lin
e 2
Larg
eK-
70 D
ate
and
Tim
eF-
12 M
otor
The
rmis
tor
Inpu
tF-
9# D
igita
l Pot
.Met
erE-
27 O
ff D
elay
, Rel
ay
K-24
Dis
play
Lin
e 3
Larg
eK-
71 D
ate
Form
atF-
15 M
otor
Spe
ed H
igh
Lim
it[H
z]F-
90 S
tep
Siz
eE-
5# I/
O M
ode
/ A
dd O
n I/
O
K-25
Qui
ck S
tart
K-72
Tim
e Fo
rmat
F-16
Mot
or S
peed
Low
Lim
it
[Hz]
F-91
Acc
el/D
ecel
Tim
eE-
51 T
erm
inal
27
Mod
e
K-3#
Key
pad
Cus
tom
Rea
dout
K-74
DST
/Sum
mer
time
F-17
Mot
or S
peed
Hig
h L
imit
[RPM
]F-
92 P
ower
Res
tore
E-52
Ter
min
al 2
9 M
ode
K-30
Uni
t fo
r Cu
stom
Rea
dout
K-76
DST
/Sum
mer
time
Star
tF-
18 M
otor
Spe
ed L
ow L
imit
[RPM
]F-
93 M
axim
um L
imit
E-53
Ter
min
al X
30/2
Dig
ital I
nput
K-31
Min
Val
ue o
f Cu
stom
Rea
dout
K-77
DST
/Sum
mer
time
End
F-
94 M
inim
um L
imit
E-54
Ter
min
al X
30/3
Dig
ital I
nput
K-32
Max
Val
ue o
f Cu
stom
Rea
dout
K-79
Clo
ck F
ault
F-
95 A
ccel
/Dec
el R
amp
Del
ayE-
55 T
erm
inal
X30
/4 D
igita
l Inp
ut
About Programming AF-600 FP Quick Guide
22 DET-759A
66
E-56
Ter
m X
30/6
Dig
i Out
(OPC
GPI
O)
E-96
Pul
se O
ut #
29 T
imeo
ut P
rese
tP-
07 M
otor
Pow
er [k
W]
H-5
# Lo
ad In
dep.
Set
.A
N-1
# A
nalo
g In
put
53
E-57
Ter
m X
30/7
Dig
i Out
(OPC
GPI
O)
E-97
Pul
se O
ut #
X30/
6 Bu
s Co
ntro
lP-
08 M
otor
Rot
atio
n C
heck
H-5
8 Fl
ysta
rt T
est
Puls
es C
urre
ntA
N-1
0 Te
rmin
al 5
3 Lo
w V
olta
ge
E-6#
Pul
se In
put
E-98
Pul
se O
ut #
X30/
6 Ti
meo
ut P
rese
tP-
09 S
lip C
ompe
nsat
ion
H-5
9 Fl
ysta
rt T
est
Puls
es F
requ
ency
AN
-11
Term
inal
53
Hig
h V
olta
ge
E-60
Ter
m. 2
9 Lo
w F
requ
ency
C-##
Fre
q C
ontr
ol F
unct
P-10
Slip
Com
pens
atio
n T
ime
Cons
tant
H-6
# Lo
ad D
epen
. Set
.A
N-1
2 Te
rmin
al 5
3 Lo
w C
urre
nt
E-61
Ter
m. 2
9 H
igh
Fre
quen
cyC-
0# F
req
Con
trol
Fun
ctP-
3# A
dv. M
otor
Dat
aH
-64
Reso
nanc
e D
ampe
ning
AN
-13
Term
inal
53
Hig
h C
urre
nt
E-62
Ter
m. 2
9 Lo
w R
ef./F
eedb
. Val
ueC-
01 J
ump
Fre
quen
cy F
rom
[Hz]
P-30
Sta
tor
Resi
stan
ce (R
s)H
-65
Reso
nanc
e D
ampe
ning
Tim
eCo
nsta
ntA
N-1
4 Te
rmin
al 5
3 Lo
w R
ef./F
eedb
.Va
lue
E-63
Ter
m. 2
9 H
igh
Ref
./Fee
db. V
alue
C-02
Jum
p S
peed
Fro
m [R
PM]
P-31
Rot
or R
esis
tanc
e (R
r)H
-7#
Adj
usta
ble
War
ning
sA
N-1
5 Te
rmin
al 5
3 H
igh
Ref
./Fee
db.
Valu
e
E-64
Pul
se F
ilter
Tim
e Co
nsta
nt #
29C-
03 J
ump
Spe
ed T
o [R
PM]
P-35
Mai
n R
eact
ance
(Xh)
H-7
0 W
arni
ng C
urre
nt L
owA
N-1
6 Te
rmin
al 5
3 Fi
lter
Tim
e Co
nsta
nt
E-65
Ter
m. 3
3 Lo
w F
requ
ency
C-04
Jum
p F
requ
ency
To
[Hz]
P-36
Iron
Los
s Re
sist
ance
(Rfe
)H
-71
War
ning
Cur
rent
Hig
hA
N-1
7 Te
rmin
al 5
3 Li
ve Z
ero
E-66
Ter
m. 3
3 H
igh
Fre
quen
cyC-
05 M
ulti-
step
Fre
quen
cy 1
- 8
H-#
# H
igh
Per
f Pa
rsH
-72
War
ning
Spe
ed L
owA
N-2
# A
nalo
g In
put
54
E-67
Ter
m. 3
3 Lo
w R
ef./F
eedb
. Val
ueC-
2# J
og S
et-u
pH
-0#
Hig
h P
erf
Ope
ratio
nsH
-73
War
ning
Spe
ed H
igh
AN
-20
Term
inal
54
Low
Vol
tage
E-68
Ter
m. 3
3 H
igh
Ref
./Fee
db. V
alue
C-20
Jog
Spe
ed [H
z]H
-03
Rest
ore
Fact
ory
Sett
ings
H-7
4 W
arni
ng R
efer
ence
Low
AN
-21
Term
inal
54
Hig
h V
olta
ge
E-69
Pul
se F
ilter
Tim
e Co
nsta
nt #
33C-
21 J
og S
peed
[RPM
]H
-04
Aut
o-Re
set
(Tim
es)
H-7
5 W
arni
ng R
efer
ence
Hig
hA
N-2
2 Te
rmin
al 5
4 Lo
w C
urre
nt
E-7#
Pul
se O
utpu
tC-
22 J
og A
ccel
/Dec
el T
ime
H-0
5 A
uto-
Rese
t (R
eset
Inte
rval
)H
-76
War
ning
Fee
dbac
k Lo
wA
N-2
3 Te
rmin
al 5
4 H
igh
Cur
rent
E-70
Ter
min
al 2
7 Pu
lse
Out
put
Varia
ble
C-3#
Fre
quen
cy S
ettin
g 2
and
3H
-06
Fan
Ope
ratio
nH
-77
War
ning
Fee
dbac
k H
igh
AN
-24
Term
inal
54
Low
Ref
./Fee
db.
Valu
e
E-71
Pul
se O
utpu
t M
ax F
req
#27
C-30
Fre
quen
cy C
omm
and
2H
-08
Reve
rse
Lock
H-7
8 M
issi
ng M
otor
Pha
se F
unct
ion
AN
-25
Term
inal
54
Hig
h R
ef./F
eedb
.Va
lue
E-72
Ter
min
al 2
9 Pu
lse
Out
put
Varia
ble
C-34
Fre
quen
cy C
omm
and
3H
-09
Star
t M
ode
H-8
# St
op A
djus
tmen
tsA
N-2
6 Te
rmin
al 5
4 Fi
lter
Tim
e Co
nsta
nt
E-74
Pul
se O
utpu
t M
ax F
req
#29
C-4#
Sem
i-Aut
o J
ump
Fre
q S
et-u
pH
-3#
Stop
Spe
edH
-80
Func
tion
at
Stop
AN
-27
Term
inal
54
Live
Zer
o
E-75
Ter
min
al X
30/6
Pul
se O
utpu
tVa
riabl
eC-
40 S
emi-A
uto
Jum
p F
req
Set
-up
H-3
6 Tr
ip S
peed
Low
[RPM
]H
-81
Min
Spe
ed fo
r Fu
nctio
n a
t St
op[R
PM]
AN
-3#
Ana
log
Inpu
t X3
0/11
E-76
Pul
se O
utpu
t M
ax F
req
#X3
0/6
P-##
Mot
or D
ata
H-3
7 Tr
ip S
peed
Low
[Hz]
H-8
2 M
in S
peed
for
Func
tion
at
Stop
[Hz]
AN
-30
Term
inal
X30
/11
Low
Vol
tage
E-9#
Bus
Con
trol
led
P-0#
Mot
or D
ata
H-4
# A
dvan
ced
Set
tings
AN
-##
Ana
log
In/O
utA
N-3
1 Te
rmin
al X
30/1
1 H
igh
Vol
tage
E-90
Dig
ital &
Rel
ay B
us C
ontr
olP-
02 M
otor
Pow
er [H
P]H
-40
Conf
igur
atio
n M
ode
AN
-0#
Ana
log
I/O
Mod
e
AN
-34
Term
. X30
/11
Low
Ref
./Fee
db.
Valu
e
E-93
Pul
se O
ut #
27 B
us C
ontr
olP-
03 M
otor
Cur
rent
H-4
3 To
rque
Cha
ract
eris
tics
AN
-00
Live
Zer
o T
imeo
ut T
ime
AN
-35
Term
. X30
/11
Hig
h R
ef./F
eedb
.Va
lue
E-94
Pul
se O
ut #
27 T
imeo
ut P
rese
tP-
04 A
uto
Tun
eH
-48
Cloc
kwis
e D
irect
ion
AN
-01
Live
Zer
o T
imeo
ut F
unct
ion
AN
-36
Term
. X30
/11
Filte
r Ti
me
Cons
tant
E-95
Pul
se O
ut #
29 B
us C
ontr
olP-
06 B
ase
Spee
d
AN
-02
Fire
Mod
e Li
ve Z
ero
Tim
eout
Func
tion
AN
-37
Term
. X30
/11
Live
Zer
o
About Programming AF-600 FP Quick Guide
DET-759A 23
6 6
AN
-4#
Ana
log
Inpu
t X3
0/12
SP-#
# Sp
ecia
l Fun
ctio
nsSP
-5#
Envi
ronm
ent
O-1
3 Co
nfig
urab
le S
tatu
s W
ord
STW
O-8
# D
rive
Port
Dia
gnos
tics
AN
-40
Term
inal
X30
/12
Low
Vol
tage
SP-1
# Li
ne O
n/O
ffSP
-50
RFI F
ilter
O-3
# D
rive
Port
Set
tings
O-8
0 Bu
s M
essa
ge C
ount
AN
-41
Term
inal
X30
/12
Hig
h V
olta
geSP
-10
Line
failu
reSP
-51
DC
Lin
k Co
mpe
nsat
ion
O-3
0 Pr
otoc
olO
-81
Bus
Erro
r Co
unt
AN
-44
Term
. X30
/12
Low
Ref
./Fee
db.
Valu
eSP
-11
Line
Vol
tage
at
Inpu
t Fa
ult
SP-5
3 Fa
n M
onito
rO
-31
Add
ress
O-8
2 Sl
ave
Mes
sage
s Rc
vd
AN
-45
Term
. X30
/12
Hig
h R
ef./F
eedb
.
Valu
eSP
-12
Func
tion
at
Line
Imba
lanc
eSP
-55
Out
put
Filte
rO
-32
Driv
e Po
rt B
aud
Rat
eO
-83
Slav
e Er
ror
Coun
t
AN
-46
Term
. X30
/12
Filte
r Ti
me
Cons
tant
SP-2
# Re
set
Func
tions
SP-5
9 A
ctua
l Num
ber
of In
vert
erU
nits
O-3
3 D
rive
Port
Par
ityO
-89
Dia
gnos
tics
Coun
t
AN
-47
Term
. X30
/12
Live
Zer
oSP
-23
Type
code
Set
ting
SP-6
# A
utom
atic
Der
ate
O-3
4 Es
timat
ed c
ycle
tim
eO
-9#
Bus
Jog
/ F
eedb
ack
AN
-5#
Ana
log
Out
put
42SP
-25
Trip
Del
ay a
t To
rque
Lim
itSP
-60
Func
tion
at
Ove
rTe
mpe
ratu
reO
-35
Min
imum
Res
pons
e D
elay
O-9
0 Bu
s Jo
g 1
Spe
ed
AN
-50
Term
inal
42
Out
put
SP-2
6 Tr
ip D
elay
at
Driv
e Fa
ult
SP-6
1 Fu
nctio
n a
t D
rive
Ove
rload
O-3
6 M
axim
um R
espo
nse
Del
ayO
-91
Bus
Jog
2 S
peed
AN
-51
Term
inal
42
Out
put
Min
Sca
leSP
-28
Prod
uctio
n S
ettin
gs
SP-6
2 D
rive
Ove
rload
Der
ate
Curr
ent
O-3
7 M
axim
um In
ter-
Char
Del
ayO
-94
Bus
Feed
back
1
AN
-52
Term
inal
42
Out
put
Max
Sca
leSP
-29
Serv
ice
Code
O-#
# O
ptio
ns /
Com
ms
O-4
# D
rive
MC
pro
toco
l set
O-9
5 Bu
s Fe
edba
ck 2
AN
-53
Term
inal
42
Out
put
Bus
Cont
rol
SP-3
# Cu
rren
t Li
mit
Ctr
l.O
-0#G
ener
al S
ettin
gsO
-40
Tele
gram
Sel
ectio
nO
-96
Bus
Feed
back
3
AN
-54
Term
inal
42
Out
put
Tim
eout
Pres
etSP
-30
Curr
ent
Lim
Ctr
l, Pr
opor
tiona
l Gai
nO
-01
Cont
rol S
iteO
-42
PCD
writ
e co
nfig
urat
ion
AO
-##
Ana
log
I/O
Opt
ion
AN
-6#
Ana
log
Out
put
X30/
8SP
-31
Curr
ent
Lim
Ctr
l, In
tegr
atio
n T
ime
O-0
2 Co
ntro
l Wor
d S
ourc
eO
-43
PCD
read
con
figur
atio
nA
O-0
# A
nalo
g I/
O M
ode
AN
-60
Term
inal
X30
/8 O
utpu
tSP
-32
Curr
ent
Lim
Ctr
l, Fi
lter
Tim
eO
-03
Cont
rol W
ord
Tim
eout
Tim
eO
-5#
Dig
ital/B
usA
O-0
0 Te
rmin
al X
42/1
Mod
e
AN
-61
Term
inal
X30
/8 M
in. S
cale
SP-4
# En
ergy
Sav
ings
O-0
4 Co
ntro
l Wor
d T
imeo
ut
Func
tion
O-5
0 Co
astin
g S
elec
tA
O-0
1 Te
rmin
al X
42/3
Mod
e
AN
-62
Term
inal
X30
/8 M
ax. S
cale
SP-4
0 VT
Lev
elO
-05
End-
of-T
imeo
ut F
unct
ion
O-5
2 D
C B
rake
Sel
ect
AO
-02
Term
inal
X42
/5 M
ode
AN
-63
Term
inal
X30
/8 O
utpu
t Bu
sCo
ntro
lSP
-41
Ener
gy S
avin
gs M
in. M
agne
tizat
ion
O-0
6 Re
set
Cont
rol W
ord
Tim
eout
O-5
3 St
art
Sele
ctA
O-1
# A
nalo
g In
put
X42/
1
AN
-64
Term
inal
X30
/8 O
utpu
t Ti
meo
utPr
eset
SP-4
2 En
ergy
Sav
ings
Min
. Fre
quen
cyO
-07
Dia
gnos
is T
rigge
rO
-54
Reve
rsin
g S
elec
tA
O-1
0 Te
rmin
al X
42/1
Low
Vol
tage
SP
-43
Mot
or C
osph
iO
-1#
Cont
rol S
ettin
gsO
-55
Set-
up S
elec
tA
O-1
1 Te
rmin
al X
42/1
Hig
h V
olta
ge
O-1
0 Co
ntro
l Wor
d P
rofil
eO
-56
Pres
et R
efer
ence
Sel
ect
AO
-14
Term
. X42
/1 L
ow R
ef./F
eedb
.
Valu
e
About Programming AF-600 FP Quick Guide
24 DET-759A
66
AO
-15
Term
. X42
/1 H
igh
Ref
./Fee
db.
Valu
eA
O-6
# A
nalo
g O
ut X
42/1
1PB
-94
Chan
ged
Par
amet
ers
(5)
EN-3
3 CI
P Re
visi
onBN
-73
MS/
TP M
ax In
fo F
ram
es
AO
-16
Term
. X42
/1 F
ilter
Tim
e Co
nsta
ntA
O-6
0 Te
rmin
al X
42/1
1 O
utpu
tEN
-##
Ethe
rnet
EN-3
4 CI
P Pr
oduc
t Co
deBN
-74
"I-A
m"
Serv
ice
AO
-17
Term
. X42
/1 L
ive
Zero
AO
-61
Term
inal
X42
/11
Min
. Sca
leEN
-0#
IP S
ettin
gsEN
-8#
Oth
er E
ther
net
Serv
ices
BN-7
5 In
itial
izat
ion
Pas
swor
d
AO
-2#
Ana
log
Inpu
t X4
2/3
AO
-62
Term
inal
X42
/11
Max
. Sca
leEN
-00
IP A
ddre
ss A
ssig
nmen
tEN
-80
FTP
Serv
er
DN
-##
Dev
iceN
et S
eria
l Com
mun
icat
ion
Bus
AO
-21
Term
inal
X42
/3 H
igh
Vol
tage
AO
-63
Term
inal
X42
/11
Bus
Cont
rol
EN-0
1 IP
Add
ress
EN-8
1 H
TTP
Serv
erD
N-0
# Co
mm
on S
ettin
gs
AO
-21
Term
inal
X42
/3 H
igh
Vol
tage
AO
-64
Term
inal
X42
/11
Tim
eout
Pre
set
EN-0
2 Su
bnet
Mas
kEN
-82
SMTP
Ser
vice
DN
-00
Dev
iceN
et P
roto
col
AO
-24
Term
. X42
/3 L
ow R
ef./F
eedb
. Val
uePB
-##
Prof
ibus
EN-0
3 D
efau
lt G
atew
ayEN
-89
Tran
spar
ent
Sock
etCh
anne
l Por
tD
N-0
1 Ba
ud R
ate
Sele
ct
AO
-25
Term
. X42
/3 H
igh
Ref
./Fee
db.
Valu
ePB
-15
PCD
Writ
e Co
nfig
urat
ion
EN-0
4 D
HCP
Ser
ver
EN-9
# A
dvan
ced
Eth
erne
tSe
rvic
esD
N-0
2 M
AC
ID
AO
-26
Term
. X42
/3 F
ilter
Tim
e Co
nsta
ntPB
-16
PCD
Rea
d C
onfig
urat
ion
EN-0
5 Le
ase
Expi
res
EN-9
0 Ca
ble
Dia
gnos
ticD
N-0
5 Re
adou
t Tr
ansm
it E
rror
Cou
nter
AO
-27
Term
. X42
/3 L
ive
Zero
PB-1
8 N
ode
Add
ress
EN-0
6 N
ame
Serv
ers
EN-9
1 M
DI-X
DN
-06
Read
out
Rece
ive
Erro
r Co
unte
r
AO
-3#
Ana
log
Inpu
t X4
2/5
PB-2
2 Te
legr
am S
elec
tion
EN-0
7 D
omai
n N
ame
EN-9
2 IG
MP
Snoo
ping
DN
-07
Read
out
Bus
Off
Cou
nter
AO
-30
Term
inal
X42
/5 L
ow V
olta
gePB
-23
Para
met
ers
for
Sign
als
EN-0
8 H
ost
Nam
eEN
-93
Cabl
e Er
ror
Leng
thD
N-1
# D
evic
eNet
AO
-31
Term
inal
X42
/5 H
igh
Vol
tage
PB-2
7 Pa
ram
eter
Edi
tEN
-09
Phys
ical
Add
ress
EN-9
4 Br
oadc
ast
Stor
mPr
otec
tion
DN
-10
Proc
ess
Dat
a Ty
pe S
elec
tion
AO
-34
Term
. X42
/5 L
ow R
ef./F
eedb
. Val
uePB
-28
Proc
ess
Cont
rol
EN-1
# Et
hern
et L
ink
Para
met
ers
EN-9
5 Br
oadc
ast
Stor
m F
ilter
DN
-11
Proc
ess
Dat
a Co
nfig
Writ
e
AO
-35
Term
. X42
/5 H
igh
Ref
./Fee
db.
Valu
ePB
-53
Prof
ibus
War
ning
Wor
dEN
-10
Link
Sta
tus
EN-9
8 In
terf
ace
Coun
ters
DN
-12
Proc
ess
Dat
a Co
nfig
Rea
d
AO
-36
Term
. X42
/5 F
ilter
Tim
e Co
nsta
ntPB
-63
Act
ual B
aud
Rat
eEN
-11
Link
Dur
atio
nEN
-99
Med
ia C
ount
ers
DN
-13
War
ning
Par
amet
er
AO
-37
Term
. X42
/5 L
ive
Zero
PB-7
0 Ed
it S
et-u
pEN
-12
Aut
o N
egot
iatio
nLN
-##
LON
WO
RKS
DN
-14
Net
Ref
eren
ce
AO
-4#
Ana
log
Out
X42
/7PB
-71
Prof
ibus
Sav
e D
ata
Valu
esEN
-13
Link
Spe
edLN
-0#
LonW
orks
IDD
N-1
5 N
et C
ontr
ol
AO
-40
Term
inal
X42
/7 O
utpu
tPB
-72
Prof
ibus
Driv
eRes
etEN
-14
Link
Dup
lex
LN-0
0 N
euro
n ID
DN
-2#
COS
Filte
rs
AO
-41
Term
inal
X42
/7 M
in. S
cale
PB-7
5 D
O Id
entif
icat
ion
EN-2
# Pr
oces
s D
ata
LN-1
# LO
N F
unct
ions
DN
-20
COS
Filte
r 1
AO
-42
Term
inal
X42
/7 M
ax. S
cale
PB-8
0 D
efin
ed P
aram
eter
s (1
)EN
-20
Cont
rol I
nsta
nce
LN-1
0 D
rive
Prof
ileD
N-2
1 CO
S Fi
lter
2
AO
-43
Term
inal
X42
/7 B
us C
ontr
olPB
-81
Def
ined
Par
amet
ers
(2)
EN-2
1 Pr
oces
s D
ata
Conf
ig W
rite
LN-1
5 LO
N W
arni
ng W
ord
DN
-22
COS
Filte
r 3
AO
-44
Term
inal
X42
/7 T
imeo
ut P
rese
tPB
-82
Def
ined
Par
amet
ers
(3)
EN-2
2 Pr
oces
s D
ata
Conf
ig R
ead
LN-1
7 XI
F Re
visi
onD
N-2
3 CO
S Fi
lter
4
AO
-5#
Ana
log
Out
X42
/9PB
-83
Def
ined
Par
amet
ers
(4)
EN-2
8 St
ore
Dat
a Va
lues
LN-1
8 Lo
nWor
ks R
evis
ion
DN
-3#
Para
met
er A
cces
s
AO
-50
Term
inal
X42
/9 O
utpu
tPB
-84
Def
ined
Par
amet
ers
(5)
EN-2
9 St
ore
Alw
ays
LN-2
# LO
N P
aram
. Acc
ess
DN
-30
Arr
ay In
dex
AO
-51
Term
inal
X42
/9 M
in. S
cale
PB-9
0 Ch
ange
d P
aram
eter
s (1
)EN
-3#
Ethe
rNet
/IPLN
-21
Stor
e D
ata
Valu
esD
N-3
1 St
ore
Dat
a Va
lues
AO
-52
Term
inal
X42
/9 M
ax. S
cale
PB-9
1 Ch
ange
d P
aram
eter
s (2
)EN
-30
War
ning
Par
amet
erBN
-##
BACn
etD
N-3
2 D
evic
enet
Rev
isio
n
AO
-53
Term
inal
X42
/9 B
us C
ontr
olPB
-92
Chan
ged
Par
amet
ers
(3)
EN-3
1 N
et R
efer
ence
BN-7
0 BA
Cnet
Dev
ice
Inst
ance
DN
-33
Stor
e A
lway
s
AO
-54
Term
inal
X42
/9 T
imeo
ut P
rese
tPB
-93
Chan
ged
Par
amet
ers
(4)
EN-3
2 N
et C
ontr
olBN
-72
MS/
TP M
ax M
aste
rsD
N-3
4 D
evic
eNet
Pro
duct
Cod
e
About Programming AF-600 FP Quick Guide
DET-759A 25
6 6
ID-#
# D
rive
Info
rmat
ion
ID-4
2 Vo
ltage
DR-
12 M
otor
Vol
tage
DR-
6# In
puts
& O
utpu
tsD
R-95
Ext
. Sta
tus
Wor
d 2
ID-0
# O
pera
ting
Dat
aID
-43
Soft
war
e Ve
rsio
nD
R-13
Fre
quen
cyD
R-60
Dig
ital I
nput
DR-
96 M
aint
enan
ce W
ord
ID-0
0 O
pera
ting
Hou
rsID
-44
GE
Mod
el N
umbe
rD
R-14
Mot
or C
urre
ntD
R-61
Ter
min
al 5
3 Sw
itch
Sett
ing
LG-#
# Lo
gs &
I/O
Opt
Sta
tus
ID-0
1 Ru
nnin
g H
ours
ID-4
5 A
ctua
l Typ
ecod
e St
ring
DR-
15 F
requ
ency
[%]
DR-
62 A
nalo
g In
put
53LG
-0#
Mai
nten
ance
Log
ID-0
2 kW
h C
ount
erID
-46
GE
Prod
uct
No.
DR-
16 T
orqu
e [N
m]
DR-
63 T
erm
inal
54
Switc
hSe
ttin
gLG
-00
Mai
nten
ance
Log
: Ite
m
ID-0
3 Po
wer
Up'
sID
-47
GE
Pow
er C
ard
Mod
el N
oD
R-17
Spe
ed [R
PM]
DR-
64 A
nalo
g In
put
54LG
-01
Mai
nten
ance
Log
: Act
ion
ID-0
4 O
ver
Tem
p's
ID-4
8 Ke
ypad
ID N
umbe
rD
R-18
Mot
or T
herm
alD
R-65
Ana
log
Out
put
42 [m
A]
LG-0
2 M
aint
enan
ce L
og: T
ime
ID-0
5 O
ver
Volt'
sID
-49
SW ID
Con
trol
Car
dD
R-22
Tor
que
[%]
DR-
66 D
igita
l Out
put
[bin
]LG
-03
Mai
nten
ance
Log
: Dat
e an
dTi
me
ID-0
6 Re
set
kWh
Cou
nter
ID-5
0 SW
ID P
ower
Car
dD
R-3#
Driv
e St
atus
DR-
67 F
req.
Inpu
t #2
9 [H
z]LG
-1#
Fire
Mod
e Lo
g
ID-0
7 Re
set
Runn
ing
Hou
rs C
ount
erID
-51
Driv
e Se
rial N
umbe
rD
R-30
DC
Lin
k Vo
ltage
DR-
68 F
req.
Inpu
t #3
3 [H
z]LG
-10
Fire
Mod
e Lo
g: E
vent
ID-0
8 N
umbe
r of
Sta
rts
ID-5
3 Po
wer
Car
d S
eria
l Num
ber
DR-
32 B
rake
Ene
rgy
/sD
R-69
Pul
se O
utpu
t #2
7 [H
z]LG
-11
Fire
Mod
e Lo
g: T
ime
ID-1
# D
ata
Tren
ding
Set
ID-6
# O
ptio
n Id
ent
DR-
33 B
rake
Ene
rgy
/2 m
inD
R-70
Pul
se O
utpu
t #2
9 [H
z]LG
-12
Fire
Mod
e Lo
g: D
ate
and
Tim
e
ID-1
0 Tr
endi
ng S
ourc
eID
-60
Opt
ion
Mou
nted
DR-
34 H
eats
ink
Tem
p.D
R-71
Rel
ay O
utpu
t [b
in]
LG-3
# I/O
Opt
ion
Sta
tus
ID-1
1 Tr
endi
ng In
terv
alID
-61
Opt
ion
SW
Ver
sion
DR-
35 D
rive
Ther
mal
DR-
72 C
ount
er A
LG-3
0 A
nalo
g In
put
X42/
1
ID-1
2 Tr
igge
r Ev
ent
ID-6
2 O
ptio
n O
rder
ing
No
DR-
36 D
rive
Nom
inal
Cur
rent
DR-
73 C
ount
er B
LG-3
1 A
nalo
g In
put
X42/
3
ID-1
3 Tr
endi
ng M
ode
ID-6
3 O
ptio
n S
eria
l No
DR-
37 D
rive
Max
. Cur
rent
DR-
75 A
nalo
g In
X30
/11
LG-3
2 A
nalo
g In
put
X42/
5
ID-1
4 Sa
mpl
es B
efor
e Tr
igge
rID
-9#
Para
met
er In
foD
R-38
Log
ic C
ontr
olle
r St
ate
DR-
76 A
nalo
g In
X30
/12
LG-3
3 A
nalo
g O
ut X
42/7
[V]
ID-2
# H
isto
ric L
ogID
-92
Def
ined
Par
amet
ers
DR-
39 C
ontr
ol C
ard
Tem
p.D
R-77
Ana
log
Out
X30
/8 [m
A]
LG-3
4 A
nalo
g O
ut X
42/9
[V]
ID-2
0 H
isto
ric L
og: E
vent
ID-9
3 M
odifi
ed P
aram
eter
sD
R-40
Tre
ndin
g B
uffe
r Fu
llD
R-8#
Ser
ial c
omm
unic
atio
nbu
s &
Driv
e Po
rtLG
-35
Ana
log
Out
X42
/11
[V]
ID-2
1 H
isto
ric L
og: V
alue
DR-
## D
ata
Read
outs
DR-
43 T
imed
Act
ions
Sta
tus
DR-
80 F
ield
bus
CTW
1A
P-##
HVA
C A
ppl.
Para
m.
ID-2
2 H
isto
ric L
og: T
ime
DR-
0# G
ener
al S
tatu
sD
R-49
Cur
rent
Fau
lt S
ourc
eD
R-82
Fie
ldbu
s RE
F 1
AP-
0# M
isce
llane
ous
ID-2
3 H
isto
ric L
og: D
ate
and
Tim
eD
R-00
Con
trol
Wor
dD
R-5#
Ref
. & F
eedb
.D
R-84
Com
m. O
ptio
n S
TWA
P-00
Ext
erna
l Int
erlo
ck D
elay
ID-3
# A
larm
Log
DR-
01 R
efer
ence
[Uni
t]D
R-50
Ext
erna
l Ref
eren
ceD
R-85
Driv
e Po
rt C
TW 1
AP-
2# N
o-Fl
ow D
etec
tion
ID-3
0 A
larm
Log
: Err
or C
ode
DR-
02 R
efer
ence
[%]
DR-
52 F
eedb
ack
[Uni
t]D
R-86
Driv
e Po
rt R
EF 1
AP-
20 L
ow P
ower
Aut
o S
et-u
p
ID-3
1 A
larm
Log
: Val
ueD
R-03
Sta
tus
Wor
dD
R-53
Dig
i Pot
Ref
eren
ceD
R-9#
Dia
gnos
is R
eado
uts
AP-
21 L
ow P
ower
Det
ectio
n
ID-3
2 A
larm
Log
: Tim
eD
R-05
Mai
n A
ctua
l Val
ue [%
]D
R-54
Fee
dbac
k 1
[Uni
t]D
R-90
Ala
rm W
ord
AP-
22 L
ow S
peed
Det
ectio
n
ID-3
3 A
larm
Log
: Dat
e an
d T
ime
DR-
09 C
usto
m R
eado
utD
R-55
Fee
dbac
k 2
[Uni
t]D
R-91
Ala
rm W
ord
2A
P-23
No-
Flow
Fun
ctio
n
ID-4
# D
rive
Iden
tific
atio
nD
R-1#
Mot
or S
tatu
sD
R-56
Fee
dbac
k 3
[Uni
t]D
R-92
War
ning
Wor
dA
P-24
No-
Flow
Del
ay
ID-4
0 D
rive
Type
DR-
10 P
ower
[kW
]D
R-58
PID
Out
put
[%]
DR-
93 W
arni
ng W
ord
2A
P-26
Dry
Pum
p F
unct
ion
ID-4
1 Po
wer
Sec
tion
DR-
11 P
ower
[hp]
D
R-94
Ext
. Sta
tus
Wor
dA
P-27
Dry
Pum
p D
elay
About Programming AF-600 FP Quick Guide
26 DET-759A
66
AP-
3# N
o-Fl
ow P
ower
Tun
ing
AP-
71 C
ompr
esso
r St
art
Max
Spe
ed [H
z]FB
-09
Fire
Mod
e A
larm
Han
dlin
gT-
14 M
aint
enan
ce D
ate
and
Tim
eCL
-03
Feed
back
2 S
ourc
e
AP-
30 N
o-Fl
ow P
ower
AP-
72 C
ompr
esso
r St
art
Max
Tim
e to
Trip
FB-1
# D
rive
Bypa
ssT-
15 R
eset
Mai
nten
ance
Wor
dCL
-04
Feed
back
2 C
onve
rsio
n
AP-
31 P
ower
Cor
rect
ion
Fac
tor
AP-
73 S
tart
ing
Acc
eler
atio
n T
ime
FB-1
0 D
rive
Bypa
ss F
unct
ion
T-16
Mai
nten
ance
Tex
tCL
-05
Feed
back
2 S
ourc
e U
nit
AP-
32 L
ow S
peed
[RPM
]A
P-75
Sho
rt C
ycle
Pro
tect
ion
FB-1
1 D
rive
Bypa
ss D
elay
Tim
eT-
5# E
nerg
y Lo
gCL
-06
Feed
back
3 S
ourc
e
AP-
33 L
ow S
peed
[Hz]
AP-
76 In
terv
al b
etw
een
Sta
rts
FB-2
0 Lo
cked
Rot
or F
unct
ion
T-50
Ene
rgy
Log
Res
olut
ion
CL-0
7 Fe
edba
ck 3
Con
vers
ion
AP-
34 L
ow S
peed
Pow
er [k
W]
AP-
77 M
inim
um R
un T
ime
FB-2
1 Lo
cked
Rot
or C
oeffi
cien
t 1
T-51
Per
iod
Sta
rtCL
-08
Feed
back
3 S
ourc
e U
nit
AP-
35 L
ow S
peed
Pow
er [H
P]A
P-8#
Flo
w C
ompe
nsat
ion
FB-2
2 Lo
cked
Rot
or C
oeffi
cien
t 2
T-53
Ene
rgy
Log
CL-1
2 Re
fere
nce/
Feed
back
Uni
t
AP-
36 H
igh
Spe
ed [R
PM]
AP-
80 F
low
Com
pens
atio
nFB
-23
Lock
ed R
otor
Coe
ffici
ent
3T-
54 R
eset
Ene
rgy
Log
CL-1
3 M
inim
um R
efer
ence
/Fee
db.
AP-
37 H
igh
Spe
ed [H
z]A
P-81
Squ
are-
linea
r Cu
rve
App
roxi
mat
ion
FB-2
4 Lo
cked
Rot
or C
oeffi
cien
t 4
T-6#
Tre
ndin
gCL
-14
Max
imum
Ref
eren
ce/F
eedb
.
AP-
38 H
igh
Spe
ed P
ower
[kW
]A
P-82
Wor
k Po
int
Calc
ulat
ion
FB-3
0 M
issi
ng M
otor
Fun
ctio
nT-
60 T
rend
Var
iabl
eCL
-20
Feed
back
Fun
ctio
n
AP-
39 H
igh
Spe
ed P
ower
[HP]
AP-
83 S
peed
at
No-
Flow
[RPM
]FB
-31
Mis
sing
Mot
or C
oeffi
cien
t 1
T-61
Con
tinuo
us B
in D
ata
CL-2
1 Se
tpoi
nt 1
AP-
4# S
leep
Mod
eA
P-84
Spe
ed a
t N
o-Fl
ow [H
z]FB
-32
Mis
sing
Mot
or C
oeffi
cien
t 2
T-62
Tim
ed B
in D
ata
CL-2
2 Se
tpoi
nt 2
AP-
40 M
inim
um R
un T
ime
AP-
85 S
peed
at
Des
ign
Poi
nt [R
PM]
FB-3
3 M
issi
ng M
otor
Coe
ffici
ent
3T-
63 T
imed
Per
iod
Sta
rtCL
-23
Setp
oint
3
AP-
41 M
inim
um S
leep
Tim
eA
P-86
Spe
ed a
t D
esig
n P
oint
[Hz]
FB-3
4 M
issi
ng M
otor
Coe
ffici
ent
4T-
64 T
imed
Per
iod
Sto
pCL
-3#
Feed
back
Adv
. Con
v
AP-
42 W
ake-
up S
peed
[RPM
]A
P-87
Pre
ssur
e at
No-
Flow
Spe
edT-
## T
imed
Fun
ctio
nsT-
65 M
inim
um B
in V
alue
CL-3
0 Re
frig
eran
t
AP-
43 W
ake-
up S
peed
[Hz]
AP-
88 P
ress
ure
at R
ated
Spe
edT-
0# T
imed
Act
ions
T-66
Res
et C
ontin
uous
Bin
Dat
aCL
-31
Use
r D
efin
ed R
efrig
eran
t A
1
AP-
44 W
ake-
up R
ef./F
B D
iffer
ence
AP-
89 F
low
at
Des
ign
Poi
ntT-
00 O
N T
ime
T-67
Res
et T
imed
Bin
Dat
aCL
-32
Use
r D
efin
ed R
efrig
eran
t A
2
AP-
45 S
etpo
int
Boos
tA
P-90
Flo
w a
t Ra
ted
Spe
edT-
01 O
N A
ctio
nT-
8# P
ayba
ck C
ount
erCL
-33
Use
r D
efin
ed R
efrig
eran
t A
3
AP-
46 M
axim
um B
oost
Tim
eFB
-##
Fire
/Byp
ass
Ope
ratio
nT-
02 O
FF T
ime
T-80
Pow
er R
efer
ence
Fac
tor
CL-3
4 D
uct
1 A
rea
[m2]
AP-
5# E
nd o
f Cu
rve
FB-0
# Fi
re M
ode
T-03
OFF
Act
ion
T-81
Ene
rgy
Cost
CL-3
5 D
uct
1 A
rea
[in2]
AP-
50 E
nd o
f Cu
rve
Func
tion
FB-0
0 Fi
re M
ode
Func
tion
T-04
Occ
urre
nce
T-82
Inve
stm
ent
CL-3
6 D
uct
2 A
rea
[m2]
AP-
51 E
nd o
f Cu
rve
Del
ayFB
-01
Fire
Mod
e Co
nfig
urat
ion
T-08
Tim
ed A
ctio
ns M
ode
T-83
Ene
rgy
Savi
ngs
CL-3
7 D
uct
2 A
rea
[in2]
AP-
6# B
roke
n B
elt
Det
ectio
nFB
-02
Fire
Mod
e U
nit
T-09
Tim
ed A
ctio
ns R
eact
ivat
ion
T-84
Cos
t Sa
ving
sCL
-38
Air
Den
sity
Fac
tor
[%]
AP-
60 B
roke
n B
elt
Func
tion
FB-0
3 Fi
re M
ode
Min
Ref
eren
ceT-
1# M
aint
enan
ceCL
-##
PID
Clo
sed-
loop
CL-7
# PI
D A
utot
unin
g
AP-
61 B
roke
n B
elt
Torq
ueFB
-04
Fire
Mod
e M
ax R
efer
ence
T-10
Mai
nten
ance
Item
CL-0
# Fe
edba
ckCL
-70
Clos
ed L
oop
Typ
e
AP-
62 B
roke
n B
elt
Del
ayFB
-05
Fire
Mod
e Pr
eset
Ref
eren
ceT-
11 M
aint
enan
ce A
ctio
nCL
-00
Feed
back
1 S
ourc
eCL
-71
PID
Per
form
ance
AP-
7# C
ompr
esso
rFB
-06
Fire
Mod
e Re
fere
nce
Sour
ceT-
12 M
aint
enan
ce T
ime
Base
CL-0
1 Fe
edba
ck 1
Con
vers
ion
CL-7
2 PI
D O
utpu
t Ch
ange
AP-
70 C
ompr
esso
r St
art
Max
Spe
ed[R
PM]
FB-0
7 Fi
re M
ode
Feed
back
Sou
rce
T-13
Mai
nten
ance
Tim
e In
terv
alCL
-02
Feed
back
1 S
ourc
e U
nit
CL-7
3 M
inim
um F
eedb
ack
Leve
l
About Programming AF-600 FP Quick Guide
DET-759A 27
6 6
CL-7
4 M
axim
um F
eedb
ack
Leve
lXC
-22
Ext.
1 In
tegr
al T
ime
XC-6
4 Ex
t. 3
Dif.
Gai
n L
imit
PC-5
2 A
ltern
atio
n T
ime
Inte
rval
LC-4
3 Lo
gic
Rule
Ope
rato
r 2
CL-7
9 PI
D A
utot
unin
gXC
-23
Ext.
1 D
iffer
enta
tion
Tim
ePC
-##
Pum
p C
ontr
olle
rPC
-53
Alte
rnat
ion
Tim
er V
alue
LC-4
4 Lo
gic
Rule
Boo
lean
3
CL-8
# PI
D B
asic
Set
tings
XC-2
4 Ex
t. 1
Dif.
Gai
n L
imit
PC-0
# Sy
stem
Set
tings
PC-5
4 A
ltern
atio
n P
rede
fined
Tim
eLC
-5#
Stat
es
CL-8
1 PI
D N
orm
al/
Inve
rse
Cont
rol
XC-3
# Ex
t. C
L 2
Ref./
Fb.
PC-0
0 Pu
mp
Con
trol
ler
PC-5
5 A
ltern
ate
if Lo
ad <
50%
LC-5
1 Lo
gic
Cont
rolle
r Ev
ent
CL-8
2 PI
D S
tart
Spe
ed [R
PM]
XC-3
0 Ex
t. 2
Ref
./Fee
dbac
k U
nit
PC-0
2 M
otor
Sta
rtPC
-56
Stag
ing
Mod
e at
Alte
rnat
ion
LC-5
2 Lo
gic
Cont
rolle
r A
ctio
n
CL-8
3 PI
D S
tart
Spe
ed [H
z]XC
-31
Ext.
2 M
inim
um R
efer
ence
PC-0
4 Pu
mp
Cyc
ling
PC-5
8 Ru
n N
ext
Pum
p D
elay
B-##
Bra
king
Fun
ctio
ns
CL-8
4 O
n R
efer
ence
Ban
dwid
thXC
-32
Ext.
2 M
axim
um R
efer
ence
PC-0
5 Fi
xed
Lea
d P
ump
PC-5
9 Ru
n o
n L
ine
Del
ayB-
0# D
C B
rake
CL-9
# PI
D C
ontr
olle
rXC
-33
Ext.
2 R
efer
ence
Sou
rce
PC-0
6 N
umbe
r of
Pum
psPC
-8#
Stat
usB-
00 D
C H
old
Cur
rent
CL-9
1 PI
D A
nti W
indu
pXC
-34
Ext.
2 F
eedb
ack
Sour
ce
PC-1
0 M
inim
um R
un T
ime
Ove
rrid
ePC
-80
Pum
p S
tatu
sB-
01 D
C B
rake
Cur
rent
CL-9
3 PI
D P
ropo
rtio
nal G
ain
XC-3
5 Ex
t. 2
Setp
oint
PC-1
1 M
inim
um R
un T
ime
Ove
rrid
e Va
lue
PC-8
1 Pu
mp
Sta
tus
B-02
DC
Bra
king
Tim
e
CL-9
4 PI
D In
tegr
al T
ime
XC-3
7 Ex
t. 2
Ref
eren
ce [U
nit]
PC-2
# Ba
ndw
idth
Set
tings
PC-8
2 Le
ad P
ump
B-03
DC
Bra
ke C
ut In
Spe
ed [R
PM]
CL-9
5 PI
D D
iffer
entia
tion
Tim
eXC
-38
Ext.
2 Fe
edba
ck [U
nit]
PC-2
0 St
agin
g B
andw
idth
PC-8
3 Re
lay
Stat
usB-
04 D
C B
rake
Cut
In S
peed
[Hz]
CL-9
6 PI
D D
iff. G
ain
Lim
itXC
-39
Ext.
2 O
utpu
t [%
]PC
-21
Ove
rrid
e Ba
ndw
idth
PC-8
4 Pu
mp
ON
Tim
eB-
1# B
rake
Ene
rgy
Func
t.
XC-#
# Ex
t. P
ID C
lose
d-lo
opXC
-4#
Ext.
CL
2 PI
DPC
-22
Fixe
d S
peed
Ban
dwid
thPC
-85
Rela
y O
N T
ime
B-10
Bra
ke F
unct
ion
XC-0
# Ex
t. CL
Aut
otun
ing
XC-4
0 Ex
t. 2
Nor
mal
/Inve
rse
Cont
rol
PC-2
3 SB
W S
tagi
ng D
elay
PC-8
6 Re
set
Rela
y Co
unte
rsB-
16 A
C b
rake
Max
. Cur
rent
XC-0
0 Cl
osed
Loo
p T
ype
XC-4
1 Ex
t. 2
Prop
ortio
nal G
ain
PC-2
4 SB
W D
esta
ging
Del
ayPC
-9#
Serv
ice
B-17
Ove
r-vo
ltage
Con
trol
XC-0
1 PI
D P
erfo
rman
ceXC
-42
Ext.
2 In
tegr
al T
ime
PC-2
5 O
BW T
ime
PC-9
0 Pu
mp
Inte
rlock
XC-0
2 PI
D O
utpu
t Ch
ange
XC-4
3 Ex
t. 2
Diff
eren
tatio
n T
ime
PC-2
6 D
esta
ge A
t N
o-Fl
owPC
-91
Man
ual A
ltern
atio
n
XC-0
3 M
inim
um F
eedb
ack
Leve
lXC
-44
Ext.
2 D
if. G
ain
Lim
itPC
-27
Stag
e Fu
nctio
nLC
-##
Logi
c Co
ntro
ller
XC-0
4 M
axim
um F
eedb
ack
Leve
lXC
-5#
Ext.
CL
3 Re
f./Fb
.PC
-28
Stag
e Fu
nctio
n T
ime
LC-0
# LC
Set
tings
XC-0
9 PI
D A
utot
unin
gXC
-50
Ext.
3 R
ef./F
eedb
ack
Uni
tPC
-29
Des
tage
Fun
ctio
nLC
-00
Logi
c Co
ntro
ller
Mod
e
XC-1
# Ex
t. C
L 1
Ref./
Fb.
XC-5
1 Ex
t. 3
Min
imum
Ref
eren
cePC
-30
Des
tage
Fun
ctio
n T
ime
LC-0
1 St
art
Even
t
XC-1
0 Ex
t. 1
Ref
./Fee
dbac
k U
nit
XC-5
2 Ex
t. 3
Max
imum
Ref
eren
cePC
-4#
Stag
ing
Set
tings
LC-0
2 St
op E
vent
XC-1
1 Ex
t. 1
Min
imum
Ref
eren
ceXC
-53
Ext.
3 R
efer
ence
Sou
rce
PC-4
0 D
ecel
Ram
p D
elay
LC-0
3 Re
set
Logi
c Co
ntro
ller
XC-1
2 Ex
t. 1
Max
imum
Ref
eren
ceXC
-54
Ext.
3 F
eedb
ack
Sour
cePC
-41
Acc
el R
amp
Del
ayLC
-1#
Com
para
tors
XC-1
3 Ex
t. 1
Ref
eren
ce S
ourc
eXC
-55
Ext.
3 S
etpo
int
PC-4
2 St
agin
g T
hres
hold
LC-1
0 Co
mpa
rato
r O
pera
nd
XC-1
4 Ex
t. 1
Fee
dbac
k So
urce
XC-5
7 Ex
t. 3
Ref
eren
ce [U
nit]
PC-4
3 D
esta
ging
Thr
esho
ldLC
-11
Com
para
tor
Ope
rato
r
XC-1
5 Ex
t. 1
Setp
oint
XC-5
8 Ex
t. 3
Feed
back
[Uni
t]PC
-44
Stag
ing
Spe
ed [R
PM]
LC-1
2 Co
mpa
rato
r Va
lue
XC-1
7 Ex
t. 1
Ref
eren
ce [U
nit]
XC-5
9 Ex
t. 3
Out
put
[%]
PC-4
5 St
agin
g S
peed
[Hz]
LC-2
# Ti
mer
s
XC-1
8 Ex
t. 1
Feed
back
[Uni
t]XC
-6#
Ext.
CL 3
PID
PC-4
6 D
esta
ging
Spe
ed [R
PM]
LC-2
0 Lo
gic
Cont
rolle
r Ti
mer
XC-1
9 Ex
t. 1
Out
put
[%]
XC-6
0 Ex
t. 3
Nor
mal
/Inve
rse
Cont
rol
PC-4
7 D
esta
ging
Spe
ed [H
z]LC
-4#
Logi
c Ru
les
XC-2
# Ex
t. C
L 1
PID
XC-6
1 Ex
t. 3
Pro
port
iona
l Gai
nPC
-5#
Alte
rnat
ion
Set
tings
LC-4
0 Lo
gic
Rule
Boo
lean
1
XC-2
0 Ex
t. 1
Nor
mal
/Inve
rse
Cont
rol
XC-6
2 Ex
t. 3
Inte
gral
Tim
ePC
-50
Lead
Pum
p A
ltern
atio
nLC
-41
Logi
c Ru
le O
pera
tor
1
XC-2
1 Ex
t. 1
Prop
ortio
nal G
ain
XC-6
3 Ex
t. 3
Diff
eren
tatio
n T
ime
PC-5
1 A
ltern
atio
n E
vent
LC-4
2 Lo
gic
Rule
Boo
lean
2
About Programming AF-600 FP Quick Guide
28 DET-759A
66
6.2 Remote Programming with DCT-10
GE has a software program available for developing,storing, and transferring drive programming. The allowsthe user to connect a PC to the drive and perform liveprogramming rather than using the keypad. Additionally,all drive programming can be done offline and simplydownloaded to thedrive. Or the entire drive profile can beloaded onto the PC for backup storage or analysis.
The USB connector or RS-485 terminal are available forconnecting to the drive.
For more details, please go to www.geelectrical.com/drives.
About Programming AF-600 FP Quick Guide
DET-759A 29
6 6
7 Warnings and Alarms
7.1 Warning and Alarm Definitions
Table 7.1 defines whether a warning is issued prior to an alarm, and whether the alarm trips the unit or trip locks the unit.
No. Description Warning Alarm/Trip Alarm/Trip Lock Parameter Reference1 10 Volts low X
2 Live zero error (X) (X) AN-01 Live Zero TimeoutFunction
4 Mains phase loss (X) (X) (X) SP-12 Function at LineImbalance
5 DC link voltage high X
6 DC link voltage low X
7 DC over voltage X X
8 DC under voltage X X
9 Inverter overloaded X X
10 Motor over temperature (X) (X) F-10 Electronic Overload
11 Motor thermistor over temperature (X) (X) F-10 Electronic Overload
12 Torque limit X X
13 Over Current X X X
14 Earth fault X X X
15 Hardware mismatch X X
16 Short Circuit X X
17 Control word timeout (X) (X) O-04 Control Word
Timeout Function
18 Start Failed
23 Internal Fan Fault X
24 External Fan Fault X SP-53 Fan Monitor
29 Drive over temperature X X X
30 Motor phase U missing (X) (X) (X) H-78 Missing Motor PhaseFunction
31 Motor phase V missing (X) (X) (X) H-78 Missing Motor Phase
Function
32 Motor phase W missing (X) (X) (X) H-78 Missing Motor PhaseFunction
33 Inrush fault X X
34 Fieldbus communication fault X X
35 Option Fault X X
36 Mains failure X X
38 Internal fault X X
39 Heatsink sensor X X
40 Overload of Digital Output Terminal 27 (X) E-00 Digital I/O Mode,E-51 Terminal 27 Mode
41 Overload of Digital Output Terminal 29 (X) E-00 Digital I/O Mode,E-52 Terminal 29 Mode
42 Overload of Digital Output On X30/6 (X) E-56 Term X30/6 Digi Out(OPCGPIO)
42 Overload of Digital Output On X30/7 (X) E-57 Term X30/7 Digi Out
(OPCGPIO)
45 45 Earth Fault 2
46 Pwr. card supply X X
Warnings and Alarms AF-600 FP Quick Guide
30 DET-759A
77
No. Description Warning Alarm/Trip Alarm/Trip Lock Parameter Reference47 24V supply low X X X
48 1.8V supply low X X
49 Speed limit X (X) H-36 Trip Speed Low [RPM]
50 calibration failed X
51 check Unom and Inom X
52 low Inom X
53 motor too big X
54 motor too small X
55 Parameter out of range X
56 interrupted by user X
57 timeout X
58 internal fault X X
59 Current limit X
60 External Interlock X
62 Output Frequency at Maximum Limit X
64 Voltage Limit X
65 Control Board Over-temperature X X X
66 Heat sink Temperature Low X
67 Option Configuration has Changed X
69 Pwr. Card Temp X X
70 Illegal Drive configuration X
76 Power Unit Setup X
79 Illegal PS config X X
80 Drive Initialized to Default Value X
91 Analog input 54 wrong settings X
92 NoFlow X X AP-2#
93 Dry Pump X X AP-2#
94 End of Curve X X AP-5#
95 Broken Belt X X AP-6#
96 Start Delayed X AP-7#
97 Stop Delayed X AP-7#
98 Clock Fault X K-7#
201 Fire M was Active
202 Fire M Limits Exceeded
203 Missing Motor
204 Locked Rotor
243 Brake IGBT X X
244 Heatsink temp X X X
245 Heatsink sensor X X
246 Pwr.card supply X X
247 Pwr.card temp X X
248 Illegal PS config X X
250 New spare parts X
251 New Type Code X X
Table 7.1 Alarm/Warning code list
(X) Dependent on parameter1) Cannot be Auto reset via H-04 Auto-Reset (Times)
NOTEPlease consult AF-600 FP Operating Instructions for detailed description and troubleshooting.
Warnings and Alarms AF-600 FP Quick Guide
DET-759A 31
7 7
8 Specifications
8.1 General Technical Data
Mains supply (L1, L2, L3):Supply voltage 200-240 V ±10%, 380-480 V ±10%, 525-600 V ±10%, 525-690 V ±10%
Mains voltage low / mains drop-out:During low mains voltage or a mains drop-out, the drive continues until the intermediate circuit voltage drops below theminimum stop level, which corresponds typically to 15% below the drive's lowest rated supply voltage. Power-up and full torquecannot be expected at mains voltage lower than 10% below the drive's lowest rated supply voltage.
Supply frequency 50/60Hz ±5%Max. imbalance temporary between mains phases 3.0% of rated supply voltageTrue Power Factor () ≥ 0.9 nominal at rated loadDisplacement Power Factor (cos) near unity (> 0.98)Switching on input supply L1, L2, L3 (power-ups) ≤ 7.5 kW/10 HP and below maximum twice/min.Switching on input supply L1, L2, L3 (power-ups) ≥ 7.5 kW/10 HP and below maximum once/min.Switching on input supply L1, L2, L3 (power-ups) ≥ 110 kW/150 HP and above maximum once/2 min.Environment according to EN60664-1 overvoltage category III / pollution degree 2
The unit is suitable for use on a circuit capable of delivering not more than 100.000 RMS symmetrical Amperes, 240/480/600 Vmaximum.
Motor output (U, V, W):Output voltage 0–100% of supply voltageOutput frequency 0–1000 Hz*Switching on output UnlimitedAccel/Decel Times 1–3600 sec.
* Dependent on power size.
Torque characteristics:Starting torque (Constant torque) maximum 110% for 1 min.*
Starting torque maximum 135% up to 0.5 sec.*
Overload torque (Constant torque) maximum 110% for 1 min.*
*Percentage relates to the adjustable frequency drive's nominal torque.
Cable lengths and cross sections:Max. motor cable length, screened/armoured 150 mMax. motor cable length, unscreened/unarmoured 300 mMaximum cross section to control terminals, rigid wire 1.5 mm2/16 AWG (2 x 0.75 mm2)Maximum cross section to control terminals, flexible cable 1 mm2/18 AWGMaximum cross section to control terminals, cable with enclosed core 0.5 mm2/20 AWGMinimum cross section to control terminals 0.25 mm2
Specifications AF-600 FP Quick Guide
32 DET-759A
88
Digital inputs:Programmable digital inputs 4 (6)Terminal number 18, 19, 27 1), 29, 32, 33,Logic PNP or NPNVoltage level 0–24V DCVoltage level, logic'0' PNP < 5V DCVoltage level, logic'1' PNP > 10V DCVoltage level, logic '0' NPN > 19 V DCVoltage level, logic '1' NPN < 14V DCMaximum voltage on input 28V DCInput resistance, Ri approx. 4kΩ
All digital inputs are galvanically isolated from the supply voltage (PELV) and other high-voltage terminals.1) Terminals 27 and 29 can also be programmed as output.
Analog inputs:Number of analog inputs 2Terminal number 53, 54Modes Voltage or currentMode select Switches A53 and A54Voltage mode Switch A53/A54 = (U)Voltage level 0 to + 10 V (scaleable)Input resistance, Ri approx. 10 kΩMax. voltage ± 20 VCurrent mode Switch A53/A54 = (I)Current level 0/4 to 20 mA (scaleable)Input resistance, Ri approx. 200 ΩMax. current 30 mAResolution for analog inputs 10 bit (+ sign)Accuracy of analog inputs Max. error 0.5% of full scaleBandwidth 200 Hz
The analog inputs are galvanically isolated from the supply voltage (PELV) and other high-voltage terminals.
Pulse inputs:Programmable pulse inputs 2Terminal number pulse 29, 33Max. frequency at terminal, 29, 33 110 kHz (push-pull driven)Max. frequency at terminal, 29, 33 5 kHz (open collector)Min. frequency at terminal 29, 33 4 HzVoltage level see section on Digital inputMaximum voltage on input 28 V DCInput resistance, Ri approx. 4 kΩPulse input accuracy (0.1–1 kHz) Max. error: 0.1% of full scaleAnalog output:Number of programmable analog outputs 1Terminal number 42Current range at analog output 0/4 - 20 mA
Specifications AF-600 FP Quick Guide
DET-759A 33
8 8
Max. resistor load to common at analog output 500 ΩAccuracy on analog output Max. error: 0.8% of full scaleResolution on analog output 8 bit
The analog output is galvanically isolated from the supply voltage (PELV) and other high-voltage terminals.
Control card, RS-485 serial communication:Terminal number 68 (P,TX+, RX+), 69 (N,TX-, RX-)Terminal number 61 Common for terminals 68 and 69
The RS-485 serial communication circuit is functionally seated from other central circuits and galvanically isolated from thesupply voltage (PELV).
Digital output:Programmable digital/pulse outputs 2Terminal number 27, 29 1)
Voltage level at digital/frequency output 0–24 VMax. output current (sink or source) 40 mAMax. load at frequency output 1 kΩMax. capacitive load at frequency output 10 nFMinimum output frequency at frequency output 0 HzMaximum output frequency at frequency output 32 kHzAccuracy of frequency output Max. error: 0.1% of full scaleResolution of frequency outputs 12 bit
1) Terminal 27 and 29 can also be programmed as input.
The digital output is galvanically isolated from the supply voltage (PELV) and other high-voltage terminals.
Control card, 24 V DC output:Terminal number 12, 13Max. load 200 mA
The 24 V DC supply is galvanically isolated from the supply voltage (PELV), but has the same potential as the analog and digitalinputs and outputs.
Relay outputs:Programmable relay outputs 2Relay 01 Terminal number 1-3 (break), 1-2 (make)Max. terminal load (AC-1)1) on 1-3 (NC), 1-2 (NO) (Resistive load) 240V AC, 2AMax. terminal load (AC-15)1) (Inductive load @ cosφ 0.4) 240V AC, 0.2AMax. terminal load (DC-1)1) on 1-2 (NO), 1-3 (NC) (Resistive load) 60V DC, 1AMax. terminal load (DC-13)1) (Inductive load) 24V DC, 0.1ARelay 02 Terminal number 4-6 (break), 4-5 (make)Max. terminal load (AC-1)1) on 4-5 (NO) (Resistive load)2)3) 400V AC, 2AMax. terminal load (AC-15)1) on 4-5 (NO) (Inductive load @ cosφ 0.4) 240V AC, 0.2AMax. terminal load (DC-1)1) on 4-5 (NO) (Resistive load) 80V DC, 2AMax. terminal load (DC-13)1) on 4-5 (NO) (Inductive load) 24V DC, 0.1AMax. terminal load (AC-1)1) on 4-6 (NC) (Resistive load) 240V AC, 2AMax. terminal load (AC-15)1) on 4-6 (NC) (Inductive load @ cosφ 0.4) 240V AC, 0.2AMax. terminal load (DC-1)1) on 4-6 (NC) (Resistive load) 50V DC, 2AMax. terminal load (DC-13)1) on 4-6 (NC) (Inductive load) 24V DC, 0.1AMin. terminal load on 1-3 (NC), 1-2 (NO), 4-6 (NC), 4-5 (NO) 24V DC 10mA, 24V AC 2 mAEnvironment according to EN 60664-1 overvoltage category III/pollution degree 2
1) IEC 60947 t 4 and 5The relay contacts are galvanically isolated from the rest of the circuit by reinforced isolation (PELV).2) Overvoltage Category II3) UL applications 300V AC 2A
Specifications AF-600 FP Quick Guide
34 DET-759A
88
Control card, 10 V DC output:Terminal number 50Output voltage 10.5 V ±0.5 VMax. load 25 mA
The 10 V DC supply is galvanically isolated from the supply voltage (PELV) and other high-voltage terminals.
Control characteristics:Resolution of output frequency at 0–1000 Hz +/- 0.003 HzSystem response time (terminals 18, 19, 27, 29, 32, 33) ≤ 2 msSpeed control range (open-loop) 1:100 of synchronous speedSpeed accuracy (open-loop) 30–4000 rpm: Maximum error of ±8 rpm
All control characteristics are based on a 4-pole asynchronous motor
Surroundings:Vibration test all enclosure types 1.0 gRelative humidity 5% - 95% (IEC 721-3-3; Class 3K3 (non-condensing) during operationAggressive environment (IEC 60068-2-43) H2S test class KdTest method according to IEC 60068-2-43 H2S (10 days)Ambient temperature (at 60 AVM switching mode)- with derating max. 50° C1)
- with full output power of typical EFF2 motors (up to 90% output current) max. 50 ° C1)
- at full continuous Drive output current max. 45 ° C1)
1) For more information on derating see the AF-600 FP Design Guide, section on Special Conditions.
Minimum ambient temperature during full-scale operation 0° CMinimum ambient temperature at reduced performance - 10° CTemperature during storage/transport -25 - +65/70° CMaximum altitude above sea level without derating 1000 mMaximum altitude above sea level with derating 3000 m
Derating for high altitude, see section on special conditions
EMC standards, Emission EN 61800-3, EN 61000-6-3/4, EN 55011, IEC 61800-3
EMC standards, ImmunityEN 61800-3, EN 61000-6-1/2,
EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6Control card performance:Scan interval 5 ms
Control Card, USB Serial Communication:USB standard 1.1 (Full speed)USB plug USB type B “device” plug
CAUTIONConnection to PC is carried out via a standard host/device USB cable.The USB connection is galvanically isolated from the supply voltage (PELV) and other high-voltage terminals.The USB connection is not galvanically isolated from protection ground. Use only isolated laptop/PC as connection to theUSB connector on drive or an isolated USB cable/drive.
Specifications AF-600 FP Quick Guide
DET-759A 35
8 8
Protection and Features:
• Electronic thermal overload motor protection against overload.
• Temperature monitoring of the heatsink ensures that the drive trips if the temperature reaches 203° F ± 9° F [95°C ± 5° C]. An overload temperature cannot be reset until the temperature of the heatsink is below 158° F ± 9° F[70° C ± 5° C] (Guideline - these temperatures may vary for different power sizes, enclosures, etc.). The drive hasan auto derating function to avoid it's heatsink reaching 203° F [95° C].
• The drive is protected against short-circuits on motor terminals U, V, W.
• If a line phase is missing, the drive trips or issues a warning (depending on the load).
• Monitoring of the intermediate circuit voltage ensures that the drive trips if the intermediate circuit voltage is toolow or too high.
• The drive is protected against ground faults on motor terminals U, V, W.
Specifications AF-600 FP Quick Guide
36 DET-759A
88
8.2.1 Fuses
It is recommended to use fuses and/ or circuit breakers on the supply side as protection in case of component break-downinside the drive (first fault).
NOTEThis is mandatory in order to ensure compliance with IEC 60364 for CE or NEC 2009 for UL.
WARNINGPersonnel and property must be protected against the consequence of internal component break-down in the drive.
Branch Circuit ProtectionIn order to protect the installation against electrical and fire hazard, all branch circuits in an installation, switch gear,machines etc., must be protected against short-circuit and overcurrent according to national/international regulations.
NOTEThe recommendations given do not cover branch circuit protection for UL.
Short-circuit protection:GE recommends using the fuses/circuit breakers mentioned below to protect service personnel and property in case ofcomponent break-down in the drive.
Overcurrent protection:The drive provides overload protection to limit threats to human life, property damage and to avoid fire hazard due tooverheating of the cables in the installation. The drive is equipped with an internal overcurrent protection (F-43 CurrentLimit) that can be used for upstream overload protection (UL applications excluded). Moreover, fuses or circuit breakers canbe used to provide the overcurrent protection in the installation. Overcurrent protection must always be provided inaccordance with national regulations.
WARNINGIn case of malfunction, not following the recommendation may result in personnel risk and damage to the drive and otherequipment.
The following tables list the recommended rated current. Recommended fuses are of the type gG for small to mediumpower sizes. For larger powers, aR fuses are recommended. Circuit breakers must be used provided they meet the national/international regulations and they limit the energy into the drive to an equal or lower level than the compliant circuitbreakers.If fuses/circuit breakers are chosen according to recommendations, possible damage to the drive will be limited to damagemainly within the unit.
8.2.2 CE Compliance
Fuses or circuit breakers are mandatory to comply with IEC 60364. GE recommend using a selection of the following.
The fuses below are suitable for use on a circuit capable of delivering 100,000 Arms (symmetrical), 240 V, or 480 V, or 500 V,or 600 V depending on the drive voltage rating. With the proper fusing, the drive short circuit current rating (SCCR) is100,000 Arms.
Specifications AF-600 FP Quick Guide
DET-759A 37
8 8
AF-600 3-phase Recommended fuse size Recommended max fuse
[HP]
1
gG-16 gG-252
3
5 gG-20 gG-32
7.5
gG-50 gG-6310
15
20gG-80 gG-125
25
30 gG-125 gG-150
40 aR-160 aR-160
50 aR-200 aR-200
60 aR-250 aR-250
Table 8.1 200–240 V, IP20/Open Chassis
AF-600 3-phase Recommended fuse size Recommended max fuse
[HP]
1
gG-20 gG-322
3
5
7.5
gG-63 gG-8010
15
20 gG-80 gG-100
25gG-125 gG-160
30
40 aR-160 aR-160
50 aR-200 aR-200
60 aR-250 aR-250
Table 8.2 200–240 V, IP55/Nema 12
Specifications AF-600 FP Quick Guide
38 DET-759A
88
AF-600 3-phase Recommended fuse size Recommended max fuse
[HP]
1
gG-16 gG-252
3
5
7.5gG-20 gG-32
10
15
gG-50 gG-6320
25
30
gG-80 gG-12540
50
60 gG-125 gG-150
75 aR-160 aR-160
100aR-250 aR-250
125
150 gG-300 gG-300
200 gG-350 gG-350
250 gG-400 gG-400
300 gG-500 gG-500
350 gG-630 gG-630
450 aR-700 aR-700
500
aR-900 aR-900550
600
650aR-1600 aR-1600
750
900aR-2000 aR-2000
1000
1200aR-2500 aR-2500
1350
Table 8.3 380–480 V, IP20/Open Chassis
Specifications AF-600 FP Quick Guide
DET-759A 39
8 8
AF-600 3-phase Recommended fuse size Recommended max fuse
[HP]
1 gG-20 gG-32
2
3
5
7.5
10
15 gG-50 gG-80
20
25
30 gG-80 gG-100
40
50 gG-125 gG-160
60
75
100 aR-250 aR-250
125
150 gG-300 gG-300
200 gG-350 gG-350
250 gG-400 gG-400
300 gG-500 gG-500
350 gG-630 gG-630
450 aR-700 aR-700
500
aR-900 aR-900550
600
650aR-1600 aR-1600
750
900aR-2000 aR-2000
1000
1200aR-2500 aR-2500
1350
Table 8.4 380–480 V, IP55/Nema 12
Specifications AF-600 FP Quick Guide
40 DET-759A
88
AF-600 3-phase Recommended fuse size Recommended max fuse
[HP]
1
gG-10 gG-252
3
5
7.5gG-16 gG-32
10
15
gG-35 gG-6320
25
30
gG-63 gG-12540
50
60gG-100 gG-150
75
100aR-250 aR-250
125
150 aR-315 aR-315
200aR-350 aR-350
250
300 aR-400 aR-400
350 aR-500 aR-500
400 aR-550 aR-550
450aR-700 aR-700
500
600aR-900 aR-900
650
750
aR-1600 aR-1600950
1000
1150
1350 aR-2000 aR-2000
Table 8.5 525–600 V, IP20/Open Chassis
Specifications AF-600 FP Quick Guide
DET-759A 41
8 8
AF-600 3-phase Recommended fuse size Recommended max fuse
[kW] / [HP]
11/15 gG-25
gG-6315/20
gG-3218.5/25
22/30 gG-40
30/40gG-63
gG-80
37/50 gG-100
45/60 gG-80 gG-125
55/75 gG-100
gG-16075/100gG-125
90/125
110/150 aR-250 aR-250
132/200 aR-315 aR-315
160/250aR-350 aR-350
200/300
250/350 aR-400 aR-400
315/450 aR-500 aR-500
400/550 aR-550 aR-550
450/600aR-700 aR-700
500/650
560/750aR-900 aR-900
630/900
710/1000
aR-1600 aR-1600800/1150
900/1250
1000/1350
1200/1600 aR-2000 aR-2000
1400/1900 aR-2500 aR-2500
Table 8.6 525-690 V, IP21/Nema 1 and IP55/Nema 12
Specifications AF-600 FP Quick Guide
42 DET-759A
88
8.2.3 NEC and UL Compliance
Fuses or circuit breakers are mandatory to comply with NEC 2009. We recommend using a selection of the following.
The fuses below are suitable for use on a circuit capable of delivering 100,000 Arms (symmetrical), 240V, or 480V, or 600Vdepending on the drive voltage rating. With the proper fusing, the drive Short Circuit Current Rating (SCCR) is 100,000 Arms.
Recommended max. fuse
AF-600 1-phasePower
AF-600 3-phasePower
Bussmann Bussmann Bussmann Bussmann Bussmann Bussmann
HP HP Type RK1 1) Type J Type T Type CC Type CC Type CC
1 KTN-R-10 JKS-10 JJN-10 FNQ-R-10 KTK-R-10 LP-CC-10
2 KTN-R-15 JKS-15 JJN-15 FNQ-R-15 KTK-R-15 LP-CC-15
2 3 KTN-R-20 JKS-20 JJN-20 FNQ-R-20 KTK-R-20 LP-CC-20
3 5 KTN-R-30 JKS-30 JJN-30 FNQ-R-30 KTK-R-30 LP-CC-30
5 7.5–10 KTN-R-50 KS-50 JJN-50 - - -
7.5 15 KTN-R-60 JKS-60 JJN-60 - - -
10 20 KTN-R-80 JKS-80 JJN-80 - - -
25–30 KTN-R-125 JKS-125 JJN-125 - - -
20 40 KTN-R-150 JKS-150 JJN-150 - - -
30 50 KTN-R-200 JKS-200 JJN-200 - - -
60 KTN-R-250 JKS-250 JJN-250 - - -
Table 8.7 200–240 V
Recommended max. fuse
AF-600 1-phasePower
AF-600 3-phasePower
SIBA Littel fuseFerraz-
ShawmutFerraz-
Shawmut
HP HP Type RK1 Type RK1 Type CC Type RK13)
1 5017906-010 KLN-R-10 ATM-R-10 A2K-10-R
2 5017906-016 KLN-R-15 ATM-R-15 A2K-15-R
2 3 5017906-020 KLN-R-20 ATM-R-20 A2K-20-R
3 5 5012406-032 KLN-R-30 ATM-R-30 A2K-30-R
5 7.5–10 5014006-050 KLN-R-50 - A2K-50-R
7.5 15 5014006-063 KLN-R-60 - A2K-60-R
10 20 5014006-080 KLN-R-80 - A2K-80-R
25–30 2028220-125 KLN-R-125 - A2K-125-R
20 40 2028220-150 KLN-R-150 - A2K-150-R
30 50 2028220-200 KLN-R-200 - A2K-200-R
60 2028220-250 KLN-R-250 - A2K-250-R
Table 8.8 200–240 V
Specifications AF-600 FP Quick Guide
DET-759A 43
8 8
Recommended max. fuse
AF-600 1-phase
AF-600 3-phase
Bussmann Littel fuseFerraz-
ShawmutFerraz-
Shawmut
HP HP Type JFHR22) Type JFHR2 Type JFHR24) Type J
1 FWX-10 - - HSJ-10
2 FWX-15 - - HSJ-15
2 3 FWX-20 - - HSJ-20
3 5 FWX-30 - - HSJ-30
5 7.5–10 FWX-50 - - HSJ-50
7.5 15 FWX-60 - - HSJ-60
10 20 FWX-80 - - HSJ-80
25–30 FWX-125 - - HSJ-125
20 40 FWX-150 L25S-150 A25X-150 HSJ-150
30 50 FWX-200 L25S-200 A25X-200 HSJ-200
60 FWX-250 L25S-250 A25X-250 HSJ-250
Table 8.9 200–240 V
1) KTS fuses from Bussmann may substitute KTN for 240 V adjustable frequency drives.
2) FWH fuses from Bussmann may substitute FWX for 240 V adjustable frequency drives.
3) A6KR fuses from FERRAZ SHAWMUT may substitute A2KR for 240 V adjustable frequency drives.
4) A50X fuses from FERRAZ SHAWMUT may substitute A25X for 240 V adjustable frequency drives.
Recommended max. fuse
AF-6001-phase
AF-6003-phase
Bussmann Bussmann Bussmann Bussmann Bussmann Bussmann
[HP] [HP] Type RK1 Type J Type T Type CC Type CC Type CC
1 KTS-R-6 JKS-6 JJS-6 FNQ-R-6 KTK-R-6 LP-CC-6
2–3 KTS-R-10 JKS-10 JJS-10 FNQ-R-10 KTK-R-10 LP-CC-10
5 KTS-R-20 JKS-20 JJS-20 FNQ-R-20 KTK-R-20 LP-CC-20
7.5 KTS-R-25 JKS-25 JJS-25 FNQ-R-25 KTK-R-25 LP-CC-25
10 KTS-R-30 JKS-30 JJS-30 FNQ-R-30 KTK-R-30 LP-CC-30
15–20 KTS-R-40 JKS-40 JJS-40 - - -
25 KTS-R-50 JKS-50 JJS-50 - - -
10 30 KTS-R-60 JKS-60 JJS-60 - - -
15 40 KTS-R-80 JKS-80 JJS-80 - - -
50 KTS-R-100 JKS-100 JJS-100 - - -
60 KTS-R-125 JKS-125 JJS-125 - - -
25 75 KTS-R-150 JKS-150 JJS-150 - - -
50 100 KTS-R-200 JKS-200 JJS-200 - - -
125 KTS-R-250 JKS-250 JJS-250 - - -
Table 8.10 380–480 V, 125 hp and below
Specifications AF-600 FP Quick Guide
44 DET-759A
88
Recommended max. fuse
AF-600 1-phase AF-600 3-phase SIBA Littel fuseFerraz-
ShawmutFerraz-
Shawmut
[HP] [HP] Type RK1 Type RK1 Type CC Type RK1
1 5017906-006 KLS-R-6 ATM-R-6 A6K-10-6
2–3 5017906-010 KLS-R-10 ATM-R-10 A6K-10-R
5 5017906-020 KLS-R-20 ATM-R-20 A6K-20-R
7.5 5017906-025 KLS-R-25 ATM-R-25 A6K-25-R
10 5012406-032 KLS-R-30 ATM-R-30 A6K-30-R
15–20 5014006-040 KLS-R-40 - A6K-40-R
25 5014006-050 KLS-R-50 - A6K-50-R
10 30 5014006-063 KLS-R-60 - A6K-60-R
15 40 2028220-100 KLS-R-80 - A6K-80-R
50 2028220-125 KLS-R-100 - A6K-100-R
60 2028220-125 KLS-R-125 - A6K-125-R
25 75 2028220-160 KLS-R-150 - A6K-150-R
50 100 2028220-200 KLS-R-200 - A6K-200-R
125 2028220-250 KLS-R-250 - A6K-250-R
Table 8.11 380–480 V, 125 hp and below
Recommended max. fuse
AF-600 1-phase AF-600 3-phase Bussmann Ferraz-Shawmut Ferraz-Shawmut Littel fuse
[HP] [HP] Type JFHR2 Type J Type JFHR21) Type JFHR2
1 FWH-6 HSJ-6 - -
2–3 FWH-10 HSJ-10 - -
5 FWH-20 HSJ-20 - -
7.5 FWH-25 HSJ-25 - -
10 FWH-30 HSJ-30 - -
15–20 FWH-40 HSJ-40 - -
25 FWH-50 HSJ-50 - -
10 30 FWH-60 HSJ-60 - -
15 40 FWH-80 HSJ-80 - -
50 FWH-100 HSJ-100 - -
60 FWH-125 HSJ-125 - -
25 75 FWH-150 HSJ-150 - -
50 100 FWH-200 HSJ-200 A50-P-225 L50-S-225
125 FWH-250 HSJ-250 A50-P-250 L50-S-250
Table 8.12 380–480 V, 125 hp and below
1) Ferraz-Shawmut A50QS fuses may substitute for A50P fuses.
Specifications AF-600 FP Quick Guide
DET-759A 45
8 8
Recommended max. fuse
AF-600 Bussmann Bussmann Bussmann Bussmann Bussmann Bussmann
[HP] Type RK1 Type J Type T Type CC Type CC Type CC
1 KTS-R-5 JKS-5 JJS-6 FNQ-R-5 KTK-R-5 LP-CC-5
2–3 KTS-R-10 JKS-10 JJS-10 FNQ-R-10 KTK-R-10 LP-CC-10
5 KTS-R20 JKS-20 JJS-20 FNQ-R-20 KTK-R-20 LP-CC-20
7.5 KTS-R-25 JKS-25 JJS-25 FNQ-R-25 KTK-R-25 LP-CC-25
10 KTS-R-30 JKS-30 JJS-30 FNQ-R-30 KTK-R-30 LP-CC-30
15–20 KTS-R-35 JKS-35 JJS-35 - - -
25 KTS-R-45 JKS-45 JJS-45 - - -
30 KTS-R-50 JKS-50 JJS-50 - - -
40 KTS-R-60 JKS-60 JJS-60 - - -
50 KTS-R-80 JKS-80 JJS-80 - - -
60 KTS-R-100 JKS-100 JJS-100 - - -
75 KTS-R-125 JKS-125 JJS-125 - - -
100 KTS-R-150 JKS-150 JJS-150 - - -
125 KTS-R-175 JKS-175 JJS-175 - - -
Table 8.13 525–600 V, 125 hp and below
Recommended max. fuse
AF-600 SIBA Littel fuseFerraz-
ShawmutFerraz-
Shawmut
[HP] Type RK1 Type RK1 Type RK1 Type J
1 5017906-005 KLS-R-005 A6K-5-R HSJ-6
2–3 5017906-010 KLS-R-010 A6K-10-R HSJ-10
5 5017906-020 KLS-R-020 A6K-20-R HSJ-20
7.5 5017906-025 KLS-R-025 A6K-25-R HSJ-25
10 5017906-030 KLS-R-030 A6K-30-R HSJ-30
15–20 5014006-040 KLS-R-035 A6K-35-R HSJ-35
25 5014006-050 KLS-R-045 A6K-45-R HSJ-45
30 5014006-050 KLS-R-050 A6K-50-R HSJ-50
40 5014006-063 KLS-R-060 A6K-60-R HSJ-60
50 5014006-080 KLS-R-075 A6K-80-R HSJ-80
60 5014006-100 KLS-R-100 A6K-100-R HSJ-100
75 2028220-125 KLS-R-125 A6K-125-R HSJ-125
100 2028220-150 KLS-R-150 A6K-150-R HSJ-150
125 2028220-200 KLS-R-175 A6K-175-R HSJ-175
Table 8.14 525–600 V, 125 hp and below
1) 170M fuses shown from Bussmann use the -/80 visual indicator. –TN/80 Type T, -/110 or TN/110 Type T indicatorfuses of the same size and amperage may be substituted.
Specifications AF-600 FP Quick Guide
46 DET-759A
88
Recommended max. fuse
AF-600 Bussmann PNAlternateExternal
Bussmann PN
AlternateExternal
Bussmann PN
AlternateExternalSiba PN
Alternate ExternalLittlefuse PN
AlternateExternalFerraz-
Shawmut PN
Alternate ExternalFerraz-Shawmut PN
[HP] Type JFHR2 Type JFHR2 Type T/JDDZ Type JFHR2 Type JFHR2 Type JFHR2
150 170M3017 FWH-300 JJS-300 2028220-315 L50-S-300 A50-P-300
200 170M3018 FWH-350 JJS-350 2028220-315 L50-S-350 A50-P-350
250 170M4012 FWH-400 JJS-400 206xx32-400 L50-S-400 A50-P-400
300 170M4014 FWH-500 JJS-500 206xx32-500 L50-S-500 A50-P-500
350 170M4016 FWH-600 JJS-600 206xx32-600 L50-S-600 A50-P-600
450 170M4017 20 610 32.700 6.9URD31D08A0700
500 170M6013 22 610 32.900 6.9URD33D08A0900
550 170M6013 22 610 32.900 6.9URD33D08A0900
600 170M6013 22 610 32.900 6.9URD33D08A0900
650 170M7081
750 170M7081
900 170M7082
1000 170M7082
1200 170M7083
1350 170M7083
Table 8.15 380–480 V, above 125 hp
AF-600 Bussmann PN Rating Alternate Siba PN
[HP]
650 170M8611 1100A, 1000V 20 781 32.1000
750 170M8611 1100A, 1000V 20 781 32.1000
900 170M6467 1400A, 700V 20 681 32.1400
1000 170M6467 1400A, 700V 20 681 32.1400
1200 170M8611 1100A, 1000V 20 781 32.1000
1350 170M6467 1400A, 700V 20 681 32.1400
Table 8.16 380–480 V, Frame Size 6, Inverter Module DC Link Fuses
Specifications AF-600 FP Quick Guide
DET-759A 47
8 8
AF-600Bussmann PN Alternate External
Siba PNAlternate External
Ferraz-Shawmut PN
[HP] Type JFHR2 Type JFHR2
150 170M3017 2061032,315 6.9URD30D08A0315
200 170M3018 2061032,35 6.9URD30D08A0350
250 170M4011 2061032,35 6.9URD30D08A0350
300 170M4012 2061032,4 6.9URD30D08A0400
350 170M4014 2061032,5 6.9URD30D08A0500
400 170M5011 2062032,55 6.9URD32D08A0550
450 170M4017 20 610 32.700 6.9URD31D08A0700
500 170M4017 20 610 32.700 6.9URD31D08A0700
600 170M6013 22 610 32.900 6.9URD33D08A0900
650 170M6013 22 610 32.900 6.9URD33D08A0900
750 170M7081
950 170M7081
1050 170M7081
1150 170M7081
1350 170M7082
1550 170M7083
Table 8.17 525–690 V, above 125 hp
AF-600 Bussmann PN Rating Alternate Siba PN
[HP]
750 170M8611 1100A, 1000V 20 781 32.1000
950 170M8611 1100A, 1000V 20 781 32.1000
1050 170M8611 1100A, 1000V 20 781 32.1000
1150 170M8611 1100A, 1000V 20 781 32.1000
1350 170M8611 1100A, 1000V 20 781 32.1000
1550 170M8611 1100A, 1000V 20 781 32.1000
Table 8.18 525–690 V, Frame Size 6, Inverter Module DC Link Fuses
*170M fuses from Bussmann shown use the -/80 visual indicator; -TN/80 Type T, -/110 or TN/110 Type T indicator fuses of the same size andamperage may be substituted for external use
**Any minimum 500 V UL listed fuse with associated current rating may be used to meet UL requirements.
Specifications AF-600 FP Quick Guide
48 DET-759A
88
9 Terminal and Applicable Wire
9.1 Cables
Pow
er [k
W /
HP]
Encl
osur
eM
ains
Mot
orLo
ad s
hare
Brak
eEa
rth*
200-
240
V38
0-48
0 V
525-
600
V52
5-69
0 V
Tigh
teni
ng
torq
ue[N
m /
in-
lbs]
Wire
siz
e[m
m2
(AW
G)]
Tigh
teni
ngto
rque
[Nm
/ in
-lb
s]
Wire
siz
e[m
m2
(AW
G)]
Tigh
teni
ng
tor
que
[Nm
/ in
-lb
s]
Wire
siz
e[m
m2
(AW
G)]
Tigh
teni
ng
torq
ue[N
m /
in-
lbs]
Wire
siz
e[m
m2
(AW
G)]
Tigh
teni
ng
torq
ue[N
m /
in-
lbs]
0.75
-2.2
kW1-
3HP
0.75
-3.7
kW1-
5HP
IP20
1.8
/ 16
4 (1
0)
1.8
/ 16
4 (1
0)1.
8 /
164
(10)
1.8
/ 16
4 (1
0)
3 /
27
3.7k
W 5
HP
5.5-
7.5k
W7.
5-10
HP
0.75
-7.5
kW1-
10H
P
IP20
0.75
-3.7
kW1-
5HP
0.75
-7.5
kW1-
10H
P0.
75-7
.5kW
1-10
HP
IP
55 o
rIP
665.
5-11
kW7.
5-15
HP
11-1
8.5k
W15
-25H
P11
-18.
5kW
15-2
5HP
IP
2016
(6)
16 (6
)16
(6)
16 (6
)5.
5-11
kW7.
5-15
HP
11-1
8.5k
W15
-25H
P11
-18.
5kW
15-2
5HP
IP
55 o
rIP
661.
5 /
141.
5 /
14
15-1
8.5k
W20
-25H
P22
-37k
W30
-50H
P22
-37k
W30
-50H
P
IP20
4.5
/ 40
35 (2
)4.
5 /
4035
(2)
4.5
/ 40
35 (2
)4.
5 /
4035
(2)
15kW
20H
P22
-30k
W30
-40H
P22
-30k
W30
-40H
P11
-30k
W15
-40H
PIP
55 o
rIP
663.
7 /
333.
7 /
33
22-3
0kW
30-4
0HP
45-5
5kW
60-7
5HP
45-5
5kW
60-7
5HP
IP
2010
/ 8
950
(1)
10 /
89
50 (1
)10
/ 8
950
(1)
10 /
89
50 (1
)
18.5
-30k
W25
-40H
P37
-55k
W50
-75H
P37
-55k
W50
-75H
P
IP55
or
IP66
90 (3
/0)
90 (3
/0)
90 (3
/0)
90 (3
/0)
37-4
5kW
50-6
0HP
75-9
0kW
100-
125H
P75
-90k
W10
0-12
5HP
IP
2014
/ 1
24
150
(300
mcm
)14
/ 1
24
150
(300
mcm
)14
/ 1
2495
(4/0
)14
/ 1
2495
(4/0
)
37-4
5kW
50-6
0HP
75-9
0kW
100-
125H
P75
-90k
W10
0-12
5HP
37-9
0kW
50-1
25H
PIP
55 o
rIP
6612
0 (4
/0)
120
(4/0
)12
0 (4
/0)
120
(4/0
)
11
0-13
2kW
150-
200H
P
110-
160k
W15
0-25
0HP
all
19 /
168
2x70
(2x2
/0)
19 /
168
2x70
(2x2
/0)
9.5
/ 84
2x70
(2x2
/0)
9.5
/ 84
2x70
(2x2
/0)
19 /
168
16
0-25
0kW
250-
350H
P
200-
400k
W30
0-55
0HP
all
2x18
5(2
x350
mcm
)2x
185
(2x3
50m
cm)
2x18
5(2
x350
mcm
)2x
185
(2x3
50m
cm)
31
5-45
0kW
450-
600H
P
450-
630k
W60
0-90
0HP
all
4x24
0(4
x500
mcm
)4x
240
(4x5
00m
cm)
19 /
168
4x24
0(4
x500
mcm
)
50
0-71
0kW
650-
1000
HP
71
0-90
0kW
1000
-125
0HP
all
8x24
0(8
x500
mcm
)
8x15
0(8
x300
mcm
)4x
120
(4x2
50m
cm)
4x18
5(4
x350
mcm
)
80
0-10
00kW
1200
-135
0HP
10
00-1
400k
W13
50-1
900H
Pal
l12
x150
(12x
300m
cm)
6x18
5(6
x350
mcm
)
* M
axim
um c
able
siz
e ac
cord
ing
to
nat
iona
l cod
e
Terminal and Applicable Wir... AF-600 FP Quick Guide
DET-759A 49
9 9
1 Seguridad
ADVERTENCIA¡ALTA TENSIÓN!Los convertidores de frecuencia contienen tensiones altascuando están conectados a una potencia de entrada dered de CA. La instalación, puesta en marcha y manteni-miento solo deben ser realizados por personal cualificado.En caso de que la instalación, el arranque y el manteni-miento no fueran efectuados por personal cualificado,podrían causarse lesiones graves o incluso la muerte.
Alta tensiónLos convertidores de frecuencia están conectados atensiones de red peligrosas. Deben extremarse las precau-ciones para evitar descargas eléctricas. La instalación,puesta en marcha y mantenimiento solo deben serrealizados por personal cualificado que esté familiarizadocon los equipos electrónicos.
ADVERTENCIA¡ARRANQUE ACCIDENTAL!Cuando el convertidor de frecuencia se conecta a la red deCA, el motor puede arrancar en cualquier momento. Elconvertidor de frecuencia, el motor y cualquier equipoaccionado deben estar listos para funcionar. Si no estánpreparados para el funcionamiento cuando se conecta elconvertidor de frecuencia a la red de CA, podrían causarselesiones personales o incluso la muerte, así como daños alequipo u otros objetos.
Arranque accidentalCuando el convertidor de frecuencia está conectado a lared de CA, el motor puede arrancar accionado por uninterruptor externo, un comando de bus serie, una señalde referencia de entrada o un fallo no eliminado. Tome lasprecauciones necesarias para protegerse contra losarranques accidentales.
ADVERTENCIA¡TIEMPO DE DESCARGA!Los convertidores de frecuencia contienen condensadoresde enlace de CC que pueden seguir cargados después deque se haya desconectado la red de CA. Para evitardescargas eléctricas, desconecte la red de CA delconvertidor de frecuencia antes de realizar cualquierreparación o tarea de mantenimiento y espere el tiempoespecificado en Tabla 1.1. Si después de desconectar laalimentación no espera el tiempo especificado antes derealizar cualquier reparación o tarea de mantenimiento enla unidad, se pueden producir daños graves o incluso lamuerte.
Tensión PotenciaTiempo de esperamínimo
200-240 V0,75-3,7 kW 1-5 CV 4 minutos
5,5-45 kW 7,5-60 CV 15 minutos
380-480 V
0,75-7,5 kW 1-10 CV 4 minutos
11-90 kW 15-125 CV 15 minutos
110-250 kW150-350 CV
20 minutos
315-1000 kW450-1350 CV
40 minutos
525-600 V
0,75-7,5 kW 1-10 CV 4 minutos
11-90 kW 15-125 CV 15 minutos
110-315 kW
150-400 CV20 minutos
355-1000 kW450-1350 CV
30 minutos
525-690 V
11-75 kW15-125 CV
15 minutos
110-400 kW150-550 CV
20 minutos
400-1400 kW600-1900 CV
30 minutos
SímbolosEn este manual se utilizan los siguientes símbolos.
Seguridad Guía rápida del AF-600 FP
DET-759A/S 1
1 1
ADVERTENCIAIndica situaciones potencialmente peligrosas que, si no seevitan, pueden producir lesiones graves e incluso lamuerte.
PRECAUCIÓNIndica una situación potencialmente peligrosa que, si no seevita, puede producir lesiones leves o moderadas. Tambiénpuede utilizarse para alertar contra prácticas inseguras.
PRECAUCIÓNIndica una situación que puede producir accidentes quedañen únicamente al equipo o a otros bienes.
¡NOTA!Indica información destacada que debe tenerse en cuentapara evitar errores o utilizar el equipo con un rendimientoinferior al óptimo.
Homologaciones
Seguridad Guía rápida del AF-600 FP
2 DET-759A/S
11
2 Introducción
Ilustración 2.1 Despiece del tamaño de la unidad 1X
1 Teclado 10 Terminales de salida del motor 96 (U), 97 (V), 98 (W)
2 Conector bus serie RS-485 (+68, –69) 11 Relé 1 (01, 02, 03)
3 Conector E / S analógico 12 Relé 2 (04, 05, 06)
4 Conector de entrada del Teclado 13 Terminales de freno (–81, +82) y carga compartida (–88, +89)
5 Conmutadores analógicos (A53, A54) 14 Terminales de entrada de red 91 (L1), 92 (L2), 93 (L3)
6 Protector de cable / conexión a tierra de protección 15 Conector USB
7 Placa de desacoplamiento 16 Interruptor terminal de bus serie
8 Abrazadera para conexión a tierra (de protección) 17 E / S digital y fuente de alimentación de 24 V
9 Abrazadera de conexión a tierra de cable apantallado y
protector de cable
18 Placa protectora del cable de control
¡NOTA!Consulte el manual de funcionamiento de AF-600 para los demás tamaños de unidad.
Introducción Guía rápida del AF-600 FP
DET-759A/S 3
2 2
3 Instalación
3.1 Lista de verificación del lugar deinstalación
• El convertidor de frecuencia utiliza el aireambiente para la refrigeración. Deben cumplirselos límites de la temperatura del aire ambientepara garantizar un funcionamiento óptimo.
• Asegúrese de que el lugar de instalación tengasuficiente fuerza de apoyo para montar elconvertidor de frecuencia.
• Mantenga el interior del convertidor defrecuencia libre de polvo y suciedad. Asegúresede que los componentes estén lo más limpiosque sea posible. Utilice una cubierta protectoraen áreas de construcción. Puede ser necesaria laprotección opcional IP54 (NEMA 12).
• Guarde el manual, los dibujos y los diagramas amano para contar con instrucciones deinstalación y funcionamiento detalladas. Esimportante que el manual esté disponible para eloperador del equipo.
• Coloque el equipo lo más cerca posible delmotor. Los cables del motor deben ser lo máscortos que sea posible. Compruebe las caracte-rísticas del motor para averiguar las toleranciasactuales. No deben superarse los siguientesvalores:
• 300 m (1000 ft) para cables del motorno apantallados.
• 150 m (500 ft) para cables apantallados.
3.2 Lista de verificación previa a lainstalación del Convertidor defrecuencia y el motor
• Compare el número de modelo de la unidad enla placa de características con el del pedido paraverificar que cuenta con el equipo correcto.
• Asegúrese de que los siguientes componentestengan la misma tensión nominal:
Red (potencia)
Convertidor de frecuencia
Motor
• Asegúrese de que la intensidad nominal de salidadel convertidor de frecuencia es igual o superiora la intensidad de carga plena del motor para unrendimiento máximo de este último.
El tamaño del motor y la potencia delconvertidor de frecuencia deben sercompatibles para conseguir unaprotección de sobrecarga adecuada.
Si el valor nominal del convertidor defrecuencia es inferior al del motor, nopodrá obtenerse una salida del motorcompleta.
3.3 Instalación mecánica
3.3.1 Refrigeración
• Para suministrar un flujo de aire de refrigeración,monte la unidad en una superficie plana sólida oen la placa posterior opcional.
• Se requiere un espacio libre por encima y pordebajo para la refrigeración por aire.Generalmente, son necesarios 100-225 mm(4-10 in).
• Un montaje incorrecto puede provocar unsobrecalentamiento y disminuir el rendimiento.
• Debe tenerse en cuenta la reducción de potenciapara temperaturas entre 40 °C (104 °F) y 50 °C(122 °F) y una elevación de 1000 m (3300 ft)sobre el nivel del mar. Consulte la Guía de Diseñopara obtener más detalles.
Ilustración 3.1 Espacio libre para refrigeración por encima y pordebajo
Instalación Guía rápida del AF-600 FP
4 DET-759A/S
33
Tensión Potencia Espacio libre a / b
200-240 V
0,25-3,7 kW 1/3-5 CV 100 mm / 4 in
5,5-30 kW 7,5-40 CV 200 mm / 8 in
> 30 kW / 40 CV 225 mm / 10 in
380-480 V
0,37-7,5 kW 1/2-10 CV 100 mm / 4 in
11-55 kW 15-75 CV 200 mm / 8 in
> 55 kW / 75 CV 225 mm / 10 in
525-600 V
0,37-7,5 kW 1/2-10 CV 100 mm / 4 in
11-55 kW 15-75 CV 200 mm / 8 in
> 55 kW / 75 CV 225 mm / 10 in
525-690 V todos 225 mm / 10 in
Tabla 3.1 Requisitos de espacio libre mínimo para el flujo de aire
3.3.2 Elevación
• Compruebe el peso de la unidad para determinarun método de elevación seguro.
• Asegúrese de que el dispositivo de elevación esidóneo para la tarea.
• Si fuera necesario, busque una grúa o carretillaelevadora adecuada para mover la unidad.
• Utilice los cáncamos de elevación para laelevación de la unidad, en caso de que los haya.
3.3.3 Montaje
• Monte la unidad en posición vertical.
• El convertidor de frecuencia permite la instalaciónlado a lado.
• Asegúrese de que la resistencia del lugar dondeva a realizar el montaje soportará el peso de launidad.
• Monte la unidad sobre una superficie plana ysólida o sobre la placa posterior opcional parasuministrar un flujo de aire de refrigeración(véase la Ilustración 3.2 y la Ilustración 3.3).
• Un montaje incorrecto puede provocar unsobrecalentamiento y disminuir el rendimiento.
• Utilice los agujeros de montaje ranurados de launidad para el montaje en pared, cuandodisponga de ellos.
Ilustración 3.2 Montaje correcto con placa posterior
El elemento A es una placa posterior instalada correc-tamente para que circule el flujo de aire necesario pararefrigerar la unidad.
Ilustración 3.3 Montaje correcto con raíles
¡NOTA!Se necesita una placa posterior cuando se realiza elmontaje con raíles.
Instalación Guía rápida del AF-600 FP
DET-759A/S 5
3 3
3.4 Instalación eléctrica
Esta sección contiene instrucciones detalladas sobre el cableado del convertidor de frecuencia. Se describen las tareassiguientes.
• Cableado del motor a los terminales de salida del convertidor de frecuencia.
• Cableado de la red de CA a los terminales de entrada del convertidor de frecuencia.
• Conexión del cableado de control y de la comunicación serie.
• Después de aplicar potencia, comprobación de la potencia del motor y de entrada y programación de losterminales de control según sus funciones previstas.
La Ilustración 3.4 muestra una conexión eléctrica básica.
Ilustración 3.4 Dibujo esquemático del cableado básico
Instalación Guía rápida del AF-600 FP
6 DET-759A/S
33
3.4.1 Requisitos
ADVERTENCIA¡PELIGRO!Los ejes en rotación y los equipos eléctricos representanun peligro. Los trabajos eléctricos deben ser conformescon los códigos eléctricos locales y nacionales. Serecomienda encarecidamente que la instalación, la puestaen marcha y el mantenimiento sean efectuadosúnicamente por personal formado y cualificado. Si noobserva estas directrices, puede provocar lesiones graves eincluso la muerte.
PRECAUCIÓN¡AISLAMIENTO DEL CABLEADO!Coloque el cableado de control, la potencia de entrada y elcableado del motor en tres conductos metálicos indepen-dientes o utilice cables apantallados separados para elaislamiento del ruido de alta frecuencia. Si no se aísla elcableado de alimentación, del motor y de control, puedeproducirse una reducción en el rendimiento óptimo delconvertidor de frecuencia y del equipo asociado.
Los siguientes requisitos deben cumplirse por suseguridad.
• El equipo de control electrónico está conectado atensión de red peligrosa. Deben extremarse lasprecauciones para evitar descargas eléctricascuando se aplica potencia a la unidad.
• Coloque los cables del motor de múltiplesconvertidores de frecuencia por separado. Latensión inducida desde los cables del motor desalida, si están juntos, puede cargar los conden-sadores del equipo, incluso si este está apagado ybloqueado.
Protección del equipo y sobrecarga
• Una función que se activa electrónicamente en elinterior del convertidor de frecuencia ofreceprotección de sobrecarga al motor. La sobrecargacalcula el nivel de aumento para activar lasecuencia para la función de desconexión (paradade salida del controlador). Cuanto mayor sea laintensidad, más rápida será la respuesta dedesconexión. La sobrecarga proporciona unaprotección contra sobrecarga del motor de clase20. Consulte en 7 Advertencias y alarmas losdetalles sobre la función de desconexión.
• Puesto que el cableado del motor transportaintensidad de alta frecuencia, es importante queel cableado de red, de potencia del motor y decontrol vayan por separado. Utilice un conductometálico o un cable apantallado separado. Si no
se aísla el cableado de control, de alimentación ydel motor, puede reducirse el rendimientoóptimo del equipo.
• Todos los convertidores de frecuencia debencontar con protección contra cortocircuitos ysobreintensidad. Se necesitan fusibles de entradapara proporcionar esta protección. Véase laIlustración 3.5. Consulte los valores nominalesmáximos de los fusibles en 8.2.2 Cumplimiento dela normativa CE y 8.2.3 Tabla de fusibles.
Ilustración 3.5 Convertidor de frecuencia Fusibles
Tipo de cables y valores nominales
• Todos los cableados deben cumplir las normasnacionales y locales sobre las secciones de cablesy temperatura ambiente.
• GE recomienda que todas las conexiones depotencia se efectúen con un cable de cobre conuna temperatura nominal mínima de 75 °C.
3.4.2 Requisitos de toma de tierra
ADVERTENCIA¡PELIGRO POR PUESTA A TIERRA!Para la seguridad del operador, es importante realizar laconexión a tierra del convertidor de frecuencia correc-tamente, de acuerdo con los códigos eléctricos nacionalesy locales y según las instrucciones incluidas en estedocumento. Las corrientes de puesta a tierra sonsuperiores a 3,5 mA. No realizar la conexión a tierracorrecta del convertidor de frecuencia podría ser causa delesiones serias e incluso muerte.
¡NOTA!Es responsabilidad del usuario o del instalador eléctricocertificado garantizar la conexión a tierra correcta delequipo de acuerdo con las normas y los códigos eléctricosnacionales y locales.
Instalación Guía rápida del AF-600 FP
DET-759A/S 7
3 3
• Siga todas las normas locales y nacionales parauna conexión eléctrica a tierra adecuada para elequipo.
• Debe establecerse una conexión a tierra correctapara el equipo con corrientes de puesta a tierrasuperiores a 3,5 mA. Véase Corriente de fuga(>3,5 mA).
• Se necesita un cable de puesta a tierra específicopara el cableado de control, de la potencia deentrada y de potencia del motor.
• Utilice las abrazaderas suministradas con elequipo para una correcta conexión a tierra.
• No conecte a tierra un convertidor de frecuenciaunido a otro en un sistema de «cadena»».
• Las conexiones a tierra deben ser lo más cortasposible.
• Se recomienda el uso de cable con muchosfilamentos para reducir el ruido eléctrico.
• Siga los requisitos de cableado del fabricante delmotor.
3.4.2.1 Corriente de fuga (> 3,5 mA)
Siga las normas locales y nacionales sobre la conexiónprotectora a tierra del equipo con una corriente de fuga >3,5 mA. La tecnología delConvertidor de frecuencia implica una conmutación de altafrecuencia con alta potencia. De este modo, se genera unacorriente de fuga en la conexión a tierra. Es posible queuna corriente a masa en los terminales de potencia desalida del convertidor de frecuencia contenga uncomponente de CC que podría cargar los condensadoresde filtro y provocar una corriente a tierra transitoria. Lacorriente de fuga a tierra depende de las diversas configu-raciones del sistema, incluido el filtro RFI, los cables delmotor apantallados y la potencia del convertidor defrecuencia.
La norma EN/CEI 61800-5-1 (estándar de producto dePower Drive Systems) requiere una atención especial si lacorriente de fuga supera los 3,5 mA. La toma de tierradebe reforzarse de una de las siguientes maneras:
• Cable de toma de tierra de 10 mm2 comomínimo
• Dos cables de toma de tierra separadosconformes con las normas de dimensionamiento
Consulte el apartado 543.7 de la norma EN 60364-5-54para obtener más información.
Uso de RCDEn caso de que se usen dispositivos de corriente residual(RCD), llamados también disyuntores de fuga a tierra(ELCB), habrá que cumplir las siguientes indicaciones:
Solo deben utilizarse RCD de tipo B capaces dedetectar corrientes de CA y CC.
Deben utilizarse RCD con un retardo de entradapara evitar fallos provocados por las corrientes atierra de transitorios.
La dimensión de los RCD debe ser conforme a laconfiguración del sistema y las consideracionesmedioambientales.
3.4.2.2 Puesta a tierra con un cableapantallado
Se suministran abrazaderas de conexión a tierra para elcableado del motor (véase la Ilustración 3.6).
Ilustración 3.6 Puesta a tierra con un cable apantallado
3.4.2.3 Puesta a tierra con un conducto
PRECAUCIÓN¡PELIGRO POR PUESTA A TIERRA!No utilice el conducto conectado al convertidor defrecuencia como sustituto de una conexión a tierraadecuada. Las corrientes de fuga a tierra son superiores a3,5 mA. Una puesta a tierra incorrecta puede provocarlesiones personales o descargas eléctricas.
Se suministran abrazaderas específicas para la conexión atierra (véase la Ilustración 3.7).
Instalación Guía rápida del AF-600 FP
8 DET-759A/S
33
Ilustración 3.7 Puesta a tierra con un conducto
Ilustración 3.8 Cableado de motor, red y toma de tierra parabastidores de tamaño 2X y superiores utilizando cableapantallado.
1. Utilice un pelacables para retirar el aislamientopara una conexión a tierra correcta.
2. Asegure la abrazadera de conexión a tierra a laporción pelada del cable utilizando los tornillossuministrados.
3. Fije el cable de conexión a tierra con laabrazadera de conexión a tierra suministrada.
3.4.3 Conexión del motor
ADVERTENCIA¡TENSIÓN INDUCIDA!Coloque los cables del motor de salida de múltiplesconvertidores de frecuencia por separado. La tensióninducida desde los cables del motor de salida, si estánjuntos, puede cargar los condensadores del equipo, inclusosi este está apagado y bloqueado. No colocar los cablesdel motor de salida separados puede provocar lesionesgraves o incluso la muerte.
• Observe los códigos eléctricos locales ynacionales en las dimensiones de los cables.Consulte
• En la base de las unidades IP55 / Nema 12 eIP66 / Nema 4X interiores se suministrantroqueles o paneles de acceso para el cableadodel motor.
• No instale condensadores de corrección del factorde potencia entre el convertidor de frecuencia yel motor.
• No conecte un dispositivo de arranque o decambio de polaridad entre el convertidor defrecuencia y el motor.
• Conecte el cableado del motor trifásico a losterminales 96 (U), 97 (V) y 98 (W).
• Ponga a tierra el cable según las instrucciones deconexión a tierra.
• Observe los requisitos de cableado del fabricantedel motor.
Las tres ilustraciones siguientes representan la entrada dered, motor y toma de tierra para convertidores defrecuencia básicos. Las configuraciones reales puedenvariar según los tipos de unidades y el equipo opcional.
3.4.4 Conexión de red de CA
• El tamaño del cableado se basa en la intensidadde entrada del convertidor de frecuencia.
• Observe los códigos eléctricos locales ynacionales en las dimensiones de los cables.Consulte .
• Conecte el cableado de alimentación de entradatrifásica de CA a los terminales L1, L2 y L3.
• Debe conectarse la alimentación de entrada a losterminales de entrada de la red.
Instalación Guía rápida del AF-600 FP
DET-759A/S 9
3 3
• Ponga a tierra el cable según las instrucciones deconexión a tierra indicadas en 3.4.2 Requisitos detoma de tierra.
• Todos los convertidores de frecuencia puedenutilizarse con una fuente de entrada aislada, asícomo con líneas de alimentación con conexión atierra. Si la alimentación proviene de una fuentede red aislada (red eléctrica IT o triánguloflotante) o de redes TT / TN-S con toma de tierra(triángulo de puesta a tierra), desconecteSP-50 Filtro RFI (póngalo en OFF). En la posiciónOFF, los condensadores de filtro RFI internos quehay entre el chasis y el circuito intermedio seaíslan para evitar dañar al circuito intermedio yreducir la intensidad capacitiva a tierra según CEI61800-3.
3.4.5 Cableado de control
• Aísle el cableado de control de los componentesde alta potencia del convertidor de frecuencia.
• Si el convertidor de frecuencia se conecta a untermistor, para el aislamiento PELV, el cableadode control del termistor opcional debe estarreforzado / doblemente aislado. Se recomiendauna tensión de alimentación de 24 V CC.
3.4.5.1 Acceso
• Retire la placa de cubierta de acceso con undestornillador. Consulte Ilustración 3.9.
• También puede retirar la cubierta frontalaflojando los tornillos de fijación. ConsulteIlustración 3.10.El par de apriete para la cubierta frontal es2,0 Nm para la unidad de tamaño 15 y 2,2 Nmpara los tamaños 2X y 3X.
Ilustración 3.9 Acceso al cableado de control de las proteccionesIP20 / con chasis abierto
Ilustración 3.10 Acceso al cableado de control de las protec-ciones IP55 / Nema 12 e IP66 / Nema 4 / 4X interior
3.4.5.2 Tipos de terminal de control
Ilustración 3.14 muestra los conectores extraíbles delconvertidor de frecuencia. Las funciones de los terminalesy los ajustes predeterminados están resumidos en laTabla 3.2.
Ilustración 3.11 Ubicación de los terminales de control
Instalación Guía rápida del AF-600 FP
10 DET-759A/S
33
• El conector 1 proporciona cuatro terminales deentrada digital programables, dos terminalesdigitales adicionales programables como entradao salida, tensión de alimentación para terminalesde 24 V CC y una opción común para la tensiónopcional suministrada por el cliente de 24 V CC.
• Los terminales del conector 2 (+)68 y (-)69 sonpara una conexión de comunicación serie RS-485.
• El conector 3 proporciona dosentradas analógicas,una salida analógica, tensión de alimentación de10 V CC y opciones comunes para entrada ysalida.
• El conector 4 es un puerto USB disponible paraser utilizado con el DCT-10.
• También se incluyen dos salidas de relé en formade C, que se encuentran en diferentesubicaciones en función de la configuración y eltamaño del convertidor de frecuencia.
• Algunas de las opciones que se pueden solicitarcon la unidad proporcionan terminalesadicionales. Consulte el manual suministrado conla opción del equipo.
Consulte 8.1 Especificaciones técnicas generales paraobtener mas información.
Descripción del terminalEntradas / salidas digitales
Terminal Parámetro
Ajustespredeter-minados Descripción
12, 13 - +24 V CC Tensión de alimen-
tación de 24 V CC. Laintensidad máxima desalida es de 200 mA
para todas las cargasde 24 V. Se utilizapara entradas digitales
y transductoresexternos.
18 E-01 [8] Arranque
Entradas digitales.
19 E-02 [0] Sin funcio-namiento
32 E-05 [0] Sin funcio-namiento
33 E-06 [0] Sin funcio-namiento
27 E-03 [0] Sin funcio-
namientoSe puede seleccionarpara entrada o salidadigital. El ajuste
predeterminado esentrada.
29 E-04 [14]VELOCIDADFIJA
Descripción del terminalEntradas / salidas digitales
Terminal Parámetro
Ajustespredeter-minados Descripción
20 - Común para entradasdigitales y 0 Vpotencial para alimen-tación de 24 V.
Entradas / salidas analógicas
39 -
Común para salidaanalógica.
42 AN-50 Velocidad 0 -
Límite alto
Salida analógica
programable. La señalanalógica es de0-20 mA o 4-20 mA a
un máximo de 500 Ω.
50 - +10 V CC Tensión de alimen-tación analógica de10 V CC. Se utilizanormalmente unmáximo de 15 mApara unpotenciómetro otermistor.
53 AN-1# Referencia Entrada analógica.
Seleccionable paratensión o intensidad.Los interruptores A53
y A54 seleccionan mAo V.
54 AN-2# Realimen-
tación
55 -
Común para entradas
analógicas.
Comunicación serie
61 -
Filtro RC integradopara el apantalla-miento de cables.SOLO para conectar elapantallamientocuando se produzcanproblemas de CEM.
68 (+) O-3# Interfaz RS-485. Elinterruptor de latarjeta de control sesuministra para laresistencia determinación.
69 (-) O-3#
Relés
01, 02, 03 E-24 [0] [0] Alarma Salida de relé en
forma de C. Se utilizapara tensión de CA oCC y cargas resistivas
o inductivas.
04, 05, 06 E-24 [1] [0] En funcio-namiento
Tabla 3.2 Descripción del terminal
Instalación Guía rápida del AF-600 FP
DET-759A/S 11
3 3
3.4.5.3 Cableado a los terminales decontrol
Los conectores del terminal de control puedendesconectarse del convertidor de frecuencia para facilitar lainstalación, tal y como se muestra en la Ilustración 3.12.
Ilustración 3.12 Desconexión de los terminales de control
1. Abra el contacto insertando un pequeño destorni-llador en la ranura situada encima o debajo delcontacto, tal y como muestra la Ilustración 3.13.
2. Inserte el cable de control desnudo en elcontacto.
3. Retire el destornillador para fijar el cable decontrol en el contacto.
4. Asegúrese de que el contacto esté bien sujeto yno esté suelto. Un cableado de control sueltopuede ser la causa de fallos en el equipo o de unfuncionamiento deficiente.
Ilustración 3.13 Conexión del cableado de control
3.4.5.4 Con cables de control apantallados
Apantallamiento correctoEn la mayoría de los casos, el método preferido consiste enfijar los cables de control y comunicación serie conabrazaderas de pantallas en ambos extremos para
garantizar el mejor contacto posible con el cable de altafrecuencia.
Lazos de tierra de 50 / 60 HzSi se utilizan cables de control muy largos, puedenaparecer lazos de tierra. Este problema se puede solucionarconectando un extremo del apantallamiento a tierramediante un condensador de 100 nF (manteniendo loscables cortos).
Evite el ruido de CEM en la comunicación seriePuede eliminarse el ruido de baja frecuencia entre conver-tidores de frecuencia si se conecta un extremo delapantallamiento al terminal 61. Este terminal se conecta atierra mediante un enlace RC interno. Utilice cables de partrenzado a fin de reducir la interferencia entreconductores.
3.4.5.5 Funciones del terminal de control
Las funciones del Convertidor de frecuencia se efectúan através de las señales de entrada de control.
• Cada terminal debe programarse para la funciónque va a asistir en los parámetros asociados conese terminal. Consulte en la Tabla 3.2 losterminales y los parámetros asociados.
• Es importante confirmar que el terminal decontrol está programado para la función correcta.
• La programación del terminal por defecto sirvepara iniciar el funcionamiento del convertidor defrecuencia en un modo operativo típico.
3.4.5.6 Conmutadores de los terminales 53y 54
• Los terminales de entrada analógicos 53 y 54pueden seleccionar señales de entrada tanto para
Instalación Guía rápida del AF-600 FP
12 DET-759A/S
33
la tensión (de 0 a 10 V) como para la corriente(de 0 o 4 a 20 mA).
• Apague la alimentación del convertidor defrecuencia antes de cambiar las posiciones delconmutador.
• Configure los conmutadores A53 y A54 paraseleccionar el tipo de señal. U selecciona latensión; I selecciona la intensidad.
• Puede accederse a los conmutadores cuando seha retirado el teclado (véase la Ilustración 3.14).Tenga en cuenta que algunas tarjetas de opcióndisponibles con la unidad podrían cubrir estosconmutadores y, por tanto, es necesario quitarlaspara cambiar la configuración de losconmutadores. Desconecte siempre la alimen-tación de la unidad antes de quitar las tarjetas deopción.
• El terminal 53 predeterminado es para una señalde referencia de velocidad en lazo abiertoconfigurada en DR-61 Ajuste interruptor terminal53.
• El terminal 54 predeterminado es para una señalde realimentación en lazo cerrado configurada enDR-63 Ajuste interruptor terminal 54.
130BT310.10
Ilustración 3.14 Ubicación de los conmutadores de los terminales53 y 54
3.4.6 Comunicación serie
es una interfaz de bus de dos hilos compatible con latopología de red multi-drop, es decir, en la que los nodosse pueden conectar como un bus, o mediante cablesconectados a una línea de tronco común. Se puedenconectar un total de 32 nodos a un segmento de red.
Los repetidores dividen los segmentos de la red. Tenga encuenta que cada repetidor funciona como un nodo dentrodel segmento en el que está instalado. Cada nodoconectado en una red determinada, debe tener unadirección de nodo única en todos los segmentos.Cada segmento debe terminarse en ambos extremos,utilizando bien el conmutador de terminación (S801) delconvertidor de frecuencia, o bien una red predispuesta deresistencias de terminación. Utilice siempre cable de partrenzado y apantallado (STP) para cablear el bus, y sigasiempre unas buenas prácticas de instalación.Es importante disponer de una conexión a toma de tierrade baja impedancia para el apantallamiento de cada nodo,también a frecuencias altas. Por ello, debe conectar unagran superficie del apantallamiento a la toma de tierra, porejemplo, por medio de una abrazadera de cable o unprensacables conductor. Puede ser necesario utilizar cablesecualizadores de potencial para mantener el mismopotencial de masa en toda la red, particularmente eninstalaciones en las que hay grandes longitudes de cable.Para evitar diferencias de impedancia, utilice siempre elmismo tipo de cable en toda la red. Cuando conecte unmotor al convertidor de frecuencia, utilice siempre cablede motor apantallado.
Cable: par trenzado apantallado (STP)
Impedancia: 120 ΩLong. de cable: máx. 1200 m (incluidos los ramales conectables)
Máx. 500 metros entre estaciones.
Instalación Guía rápida del AF-600 FP
DET-759A/S 13
3 3
4 Arranque y pruebas de funcionamiento
4.1 Arranque previo
4.1.1 Inspección de seguridad
ADVERTENCIA¡ALTA TENSIÓN!Si las conexiones de entrada y salida se han conectadoincorrectamente, existe la posibilidad de que pase altatensión por estos terminales. Si los cables de potencia paramotores múltiples discurren incorrectamente por el mismoconducto, existe la posibilidad de que la corriente de fugacargue los condensadores dentro del convertidor defrecuencia, incluso estando desconectado de la entrada dered. Para el arranque inicial, no dé nada por sentado sobrelos componentes de potencia. Siga los procedimientosprevios al arranque. Si no sigue estos procedimientosprevios al arranque podrían provocarse lesiones personaleso daños al equipo.
1. La potencia de entrada de la unidad debe estardesactivada y bloqueada. No confíe en losinterruptores de desconexión del convertidor defrecuencia para aislar la potencia de entrada.
2. Verifique que no hay tensión en los terminales deentrada L1 (91), L2 (92) y L3 (93), entre fases y defase a conexión a tierra.
3. Verifique que no hay tensión en los terminales desalida 96 (U), 97(V) y 98 (W), entre fases y de fasea conexión a tierra.
4. Confirme la continuidad del motor midiendo losvalores en ohmios en U-V (96-97), V-W (97-98) yW-U (98-96).
5. Compruebe la correcta conexión a tierra delconvertidor de frecuencia y del motor.
6. Revise el convertidor de frecuencia en busca deconexiones o terminales flojos.
7. Registre los siguientes datos de la placa decaracterísticas del motor: potencia, tensión,frecuencia, corriente a plena carga y velocidadnominal. Estos valores son necesarios paraprogramar los datos de la placa de característicasdel motor más adelante.
8. Compruebe si la tensión de alimentación coincidecon la del convertidor de frecuencia y del motor.
Arranque y pruebas de funci... Guía rápida del AF-600 FP
14 DET-759A/S
44
4.1.2 Lista de verificación del arranque
PRECAUCIÓNAntes de aplicar potencia a la unidad, inspeccione toda la instalación tal y como se indica en la Tabla 4.1. Marque loselementos una vez los haya inspeccionado.
Inspeccionar Descripción Equipo auxiliar • Busque los equipos auxiliares, conmutadores, desconectores, fusiblesde entrada
o magnetotérmicos que pueda haber en el lado de la potencia de entrada delconvertidor de frecuencia o en el de salida al motor. Asegúrese de que estánlistos para un funcionamiento a máxima velocidad.
• Compruebe el estado funcional y la instalación de los sensores utilizados parala realimentación al convertidor de frecuencia.
• Elimine las tapas de corrección del factor de potencia en los motores, siestuvieran presentes.
Recorrido de los cables • Asegúrese de que la potencia de entrada, el cableado del motor y el cableadode control están separados o van por tres conductosmetálicos independientespara el aislamiento del ruido de alta frecuencia.
Cableado de control • Compruebe que no existan cables rotos o dañados ni conexiones flojas.
• Compruebe que el cableado de control está aislado del cableado de control yde potencia para protegerlo contra los ruidos.
• Compruebe la fuente de tensión de las señales, si fuera necesario.
• Se recomienda el uso de un cable apantallado o de par trenzado. Asegúrese deque la pantalla está correctamente terminada.
Espacio libre para la refrige-ración
• Realice las mediciones necesarias para comprobar que la zona despejada porencima y por debajo es adecuada para garantizar el flujo de aire correcto parasu refrigeración.
Consideraciones sobre CEM • Compruebe que la instalación es correcta en cuanto a compatibilidad electro-magnética.
Consideraciones medioam-bientales
• Consulte en la etiqueta del equipo los límites de temperatura de latemperatura ambiente de funcionamiento máxima.
• Los niveles de humedad deben ser inferiores al 5-95 % sin condensación.
Fusibles y magnetotérmicos • Compruebe si los fusibles o magnetotérmicos son los adecuados.
• Compruebe que todos los fusibles estén bien insertados y en buen estado, yque todos los magnetotérmicos estén en la posición abierta.
Toma de tierra • La unidad requiere un cable de conexión a tierra desde su chasis hasta la tomade tierra de la planta.
• Compruebe que las conexiones a tierra son buenas y están bien apretadas ylibres de óxido.
• La conexión a tierra a un conducto o el montaje del panel posterior en unasuperficie metálica no se considera una conexión a tierra adecuada.
Cableado de entrada y salidade alimentación
• Revise posibles conexiones sueltas.
• Compruebe que el motor y la red están en conductos separados o en cablesapantallados separados.
Interior del panel • Compruebe que el interior de la unidad está libre de suciedad, virutasmetálicas, humedad y corrosión.
Interruptores • Asegúrese de que todos los ajustes de conmutación y desconexión se
encuentren en las posiciones correctas.
Arranque y pruebas de funci... Guía rápida del AF-600 FP
DET-759A/S 15
4 4
Inspeccionar Descripción Vibración • Compruebe que la unidad está montada de manera sólida, o bien sobre
soportes que amortigüen los golpes, en caso necesario.
• Compruebe que no exista ninguna vibración excesiva.
Tabla 4.1 Lista de verificación del arranque
4.2 Aplicar potencia al Convertidor de frecuencia
ADVERTENCIA¡ALTA TENSIÓN!Los convertidores de frecuencia contienen tensiones altascuando están conectados a la red de CA. La instalación,puesta en marcha y mantenimiento solo deben serrealizados por personal cualificado. No seguir estasrecomendaciones puede ser causa de lesiones serias eincluso muerte.
ADVERTENCIA¡ARRANQUE ACCIDENTAL!Cuando el convertidor de frecuencia se conecta a la red deCA, el motor puede arrancar en cualquier momento. Elconvertidor de frecuencia, el motor y cualquier equipoaccionado deben estar listos para funcionar. En casocontrario, podrían causarse lesiones personales o incluso lamuerte, así como daños al equipo u otros objetos.
1. Confirme que la tensión de entrada estáequilibrada en un margen del 3 %. De no ser así,corrija el desequilibrio de tensión de entradaantes de continuar. Repita el procedimientodespués de corregir la tensión.
2. Asegúrese de que el cableado del equipoopcional si lo hay, es compatible con la aplicaciónde la instalación.
3. Asegúrese de que todos los dispositivos deloperador están en la posición OFF. Las puertasdel panel deben estar cerradas o montadas en lacubierta.
4. Aplique potencia a la unidad. NO arranque elconvertidor de frecuencia en este momento. En elcaso de las unidades con un interruptor dedesconexión, seleccione la posición ON paraaplicar potencia al convertidor de frecuencia.
4.3 Programación operativa básica
Los convertidores de frecuencia necesitan una progra-mación operativa básica antes de poder funcionar a plenorendimiento. La programación operativa básica requiere laintroducción de los datos de la placa de características delmotor para que el este pueda ponerse en funcionamientoy la velocidad del motor máxima y mínima. Introduzca los
datos de acuerdo con el siguiente procedimiento. Losajustes de parámetros recomendados se proporcionan parael arranque y la comprobación. Los ajustes de la aplicaciónpueden variar.
Estos datos deben introducirse con la alimentaciónconectada, pero antes de que empiece a funcionar elconvertidor de frecuencia.
1. Pulse la tecla [Quick Menu] (Menú rápido) en elteclado.
2. Utilice las teclas de navegación para avanzarhasta Arranque rápido y pulse [OK] (Aceptar).
3. Seleccione el idioma y pulse [OK] (Aceptar).Introduzca los datos de motor en los parámetrosP-02, P-03, P-06, P-07, F-04 y F-05 (únicamente enlos motores de inducción; con los motores PMomita estos pasos de momento). Encontrará lainformación en la placa de características delmotor. El menú rápido al completo se muestraen .
P-07 Potencia motor [kW] o P-02 Potenciamotor [CV]
F-05 Tensión nominal del motor
F-04 Frecuencia
P-03 Intensidad del motor
P-06 Velocidad básica
4. En F-07 Tiempo acel 1, se recomiendan 60segundos para ventiladores o 10 segundos parabombas.
5. En F-08 Tiempo decel 1, se recomiendan 60segundos para ventiladores o 10 segundos parabombas.
6. Para F-10 introduzca SC elec. Descon. 1 para laprotección de sobrecarga de clase 20. Paraobtener más información, consulte la sección3.4.1 Requisitos.
7. Introduzca los requisitos de aplicación paraF-16 Límite bajo veloc. motor [Hz]. Si desconoceestos valores en este momento, se recomiendanlos siguientes. Estos valores garantizarán elfuncionamiento inicial del convertidor de
Arranque y pruebas de funci... Guía rápida del AF-600 FP
16 DET-759A/S
44
frecuencia. No obstante, debe tomar todas lasprecauciones necesarias para evitar daños en elequipo. Asegúrese de que los valoresrecomendados son seguros para su uso en laspruebas de funcionamiento antes de arrancar elequipo.
Ventilador = 20 Hz
Bomba = 20 Hz
Compresor = 30 Hz
8. En F-15 Límite alto veloc. motor [Hz] introduzca lafrecuencia del motor de F-04 Frecuencia.
Así concluye el procedimiento de configuración rápida.Pulse [Status] (Estado) para volver al display deoperaciones.
En P-04 Autoajuste seleccione Autoajuste reducido oAutoajuste completo y siga las instrucciones de la pantalla.Consulte 4.4 Autoajuste
4.4 Autoajuste
Elautoajuste es un procedimiento de prueba que mide lascaracterísticas eléctricas del motor para optimizar lacompatibilidad entre el convertidor de frecuencia y elmotor.
• El convertidor de frecuencia se basa en unmodelo matemático para regular la intensidad delmotorde salida. El procedimiento también sometea prueba el equilibrio de la fase de entrada de lapotencia eléctrica y compara las característicasdel motor con los datos introducidos en losparámetros P-02, P-03, P-06, P-07, F-04 y F-05.
• Esto no hace que el motor funcione y tampoco lodaña.
• Algunos motores pueden no ser capaces deejecutar toda la versión de la prueba. En ese caso,seleccione Autoajuste reducido
• Si hay un filtro de salida conectado al motor,seleccione Autoajuste reducido
• Si tienen lugar advertencias o alarmas, consulte 7 Advertencias y alarmas
4.5 Comprobación del giro del motor
Antes de hacer funcionar el convertidor de frecuencia,compruebe el giro del motor. El motor funcionarábrevemente a 5 Hz o a la frecuencia mínima fijada enF-16 Límite bajo veloc. motor [Hz].
1. Pulse [Main Menu] (Menú principal) dos veces enel teclado.
2. Introduzca los datos de parámetros, desplácesehasta P-## Datos motor y pulse [OK] (Aceptar).
3. Desplácese hasta P-08 Comprob. rotación motor.
4. Pulse [OK] (Aceptar).
5. Desplácese hasta Activar.
Aparecerá el siguiente texto: Nota: el motor puede girar enel sentido equivocado.
6. Pulse [OK] (Aceptar).
7. Siga las instrucciones en pantalla.
Para cambiar el sentido de giro, apague la alimentacióndel convertidor de frecuencia y espere hasta que sedescargue. Invierta la conexión de dos cables cualesquierade los tres cables de motor en el lado del motor o delconvertidor de frecuencia de la conexión.
4.6 Prueba de control local
PRECAUCIÓN¡ARRANQUE DEL MOTOR!Asegúrese de que el motor, el sistema y cualquier equipoconectado están listos para arrancar. Es responsabilidad delusuario garantizar un funcionamiento seguro bajocualquier circunstancia. De lo contrario, podrían provocarselesiones graves o daños al equipo.
¡NOTA!La tecla [Hand] (Manual) del teclado proporciona uncomando de arranque local para el convertidor defrecuencia. La tecla OFF es la función de parada.Cuando funciona en modo local, las flechas arriba y abajoen el teclado aumentan o disminuyen la salida develocidad del convertidor de frecuencia. Las teclas deflecha de izquierda y derecha mueven el cursor por eldisplay numérico.
1. Pulse [Hand].
2. Acelere el convertidor de frecuencia pulsando []hasta la velocidad máxima. Si se mueve el cursora la izquierda de la coma decimal, se consiguenefectuar los cambios de entrada másrápidamente.
3. Observe cualquier problema de aceleración.
4. Pulse [OFF] (Apagar).
5. Observe cualquier problema de desaceleración.
Si se detectan problemas de aceleración:
• Si tienen lugar advertencias o alarmas, consulte 7 Advertencias y alarmas
• Compruebe que los datos del motor se hanintroducido correctamente.
Arranque y pruebas de funci... Guía rápida del AF-600 FP
DET-759A/S 17
4 4
• Incremente el tiempo de acel. en F-07 Tiempo acel1.
• Incremente el límite de intensidad en F-43 Límiteintensidad.
• Incremente el límite de par en F-40 Limitador depar (funcionam.).
Si se detectan problemas de desaceleración:
• Si tienen lugar advertencias o alarmas, consulte 7 Advertencias y alarmas
• Compruebe que los datos del motor se hanintroducido correctamente.
• Incremente el tiempo de desacel. en F-08 Tiempodecel 1.
Consulte 7.1 Definiciones de advertencia y alarma parareiniciar el convertidor de frecuencia tras una desconexión.
¡NOTA!Los apartados 4.1 Arranque previo a 4.6 Prueba de controllocal de este capítulo concluyen los procedimientos paraaplicar potencia al convertidor de frecuencia, la progra-mación básica, la configuración y las pruebas defuncionamiento.
4.7 Arranque del sistema
El procedimiento de este apartado requiere que se hayacompletado el cableado por parte del usuario y la progra-mación de la aplicación. pretende servir de ayuda en estatarea. Se recomienda el siguiente procedimiento una vezque el usuario ha finalizado la configuración de laaplicación.
PRECAUCIÓN¡ARRANQUE DEL MOTOR!Asegúrese de que el motor, el sistema y cualquier equipoconectado están listos para arrancar. Es responsabilidad delusuario garantizar un funcionamiento seguro bajocualquier circunstancia operativa. De lo contrario, podríanprovocarse lesiones graves o daños al equipo.
1. Pulse [Auto].
2. Asegúrese de que las funciones de controlexterno están correctamente conectadas alconvertidor de frecuencia y que toda la progra-mación está completada.
3. Aplique un comando de ejecución externo.
4. Ajuste la referencia de velocidad en todo elintervalo de velocidad.
5. Elimine el comando de ejecución externo.
6. Observe cualquier problema.
Si se producen advertencias o alarmas, consulte7 Advertencias y alarmas.
Arranque y pruebas de funci... Guía rápida del AF-600 FP
18 DET-759A/S
44
5 Interfaz de usuario
5.1 Teclado
El teclado es la pantalla y las teclas combinadas de la partefrontal de la unidad. El teclado es la interfaz de usuariocon el convertidor de frecuencia.
El teclado cuenta con varias funciones de usuario.
• Arranque, parada y control de velocidad cuandoestá en control local.
• Visualización de los datos de funcionamiento,estado, advertencias y precauciones.
• Programación de las funciones del convertidor defrecuencia.
• Reinicio manual del convertidor de frecuencia trasun fallo cuando el reinicio automático estáinactivo
¡NOTA!Puede ajustar el contraste del display pulsando [STATUS] yla tecla arriba / abajo.
5.1.1 Diseño del Teclado
El teclado se divide en cuatro grupos funcionales (véaseIlustración 5.1).
Ilustración 5.1 Teclado
a. Área del display.
b. Teclas del menú de display para cambiar eldisplay y visualizar opciones de estado, progra-mación o historial de mensajes de error.
c. Teclas de navegación para programar funciones,desplazar el cursor del display y controlar lavelocidad en funcionamiento local. Tambiénincluye luces indicadoras de estado.
d. Teclas de modo de funcionamiento y reinicio.
Interfaz de usuario Guía rápida del AF-600 FP
DET-759A/S 19
5 5
5.1.2 Configuración de los valores dedisplay del Teclado
El área del display se activa cuando el convertidor defrecuencia recibe potencia de la tensión de red, a través deun terminal de bus CC o de una fuente de alimentaciónexterna de 24 V.
La información visualizada en el teclado puede persona-lizarse para la aplicación del usuario.
• Cada lectura del display tiene un parámetroasociado.
• Las opciones se seleccionan en el menú rápidoAjuste teclado.
• El display 2 cuenta con una opción alternativa dedisplay más grande.
• El estado del convertidor de frecuencia en la líneainferior del display se genera automáticamente yno puede seleccionarse.
Display número de parámetro Ajustes predeter-
minados
1.1 K-20 RPM del motor
1.2 K-21 Intensidad del motor
1.3 K-22 Potencia del motor(kW)
2 K-23 Frecuencia del motor
3 K-24 Referencia en
porcentaje
5.1.3 Teclas de menú del display
Las teclas del menú se utilizan para acceder al menú deajuste de los parámetros, para cambiar entre los modos deldisplay de estado durante el funcionamiento normal y paravisualizar los datos del registro de fallos.
Tecla FunciónEstado Púlsela para mostrar la información del funcio-
namiento.
• En modo automático, manténgala pulsadapara cambiar entre las pantallas de lectura
de estado.
• Púlsela repetidamente para avanzar porcada pantalla de estado.
• Mantenga pulsada la tecla [Status] (Estado)
y [] o [] para ajustar el brillo de la
pantalla.
• El símbolo de la esquina superior derechadel display muestra el sentido de giro delmotor y qué configuración está activa. Noes programable.
Menú rápido Permite acceder a parámetros de programaciónpara obtener instrucciones de configuracióninicial, así como muchas otras instruccionesdetalladas sobre la aplicación.
• Pulse para acceder a Arranque rápido paraseguir las instrucciones de la pantalla paraprogramar la configuración del controladorde frecuencia básica.
• Púlsela para acceder a Macros de ventilador,Macros de bomba o Lazo cerrado y recibiruna secuencia de instrucciones paraprogramar las aplicaciones.
• Pulse para acceder a Tendencia para unregistro en tiempo real en el display delteclado.
• Pulse para acceder a Comprobación de
datos de parámetros para los cambios en elconjunto de datos de parámetros.
• Siga la secuencia de parámetros como sepresentan para la configuración de lafunción.
Interfaz de usuario Guía rápida del AF-600 FP
20 DET-759A/S
55
Tecla FunciónMenú principal Permite el acceso a todos los parámetros de
programación.
• Púlsela dos veces para acceder al índice denivel superior.
• Púlsela una vez para volver al último puntoal que accedió.
• Manténgala pulsada para introducir unnúmero de parámetro y accederdirectamente a dicho parámetro.
Registro de
alarmas
Muestra una relación de advertencias actuales,
las últimas 10 alarmas y el registro de manteni-miento.
• Para obtener más información sobre el
convertidor de frecuencia antes de queentrase en el modo de alarma, seleccione elnúmero de alarma utilizando las teclas de
navegación y pulse [OK] (Aceptar).
5.1.4 Teclas de navegación
Las teclas de navegación se utilizan para programarfunciones y desplazar el cursor de la pantalla. Las teclas denavegación también permiten el control de velocidad enfuncionamiento (manual) local. En esta área, también selocalizan tres luces indicadoras del estado del convertidorde frecuencia.
Tecla Función
[Back] Vuelve al paso o lista anterior en la estructura delmenú.
[Cancel] Cancela el último cambio o comando, siempre y
cuando el modo de pantalla no haya cambiado.
[Info] Púlsela para obtener una definición de la funciónque se está visualizando.
Teclas denavegación
Utilice las cuatro flechas de navegación paradesplazarse entre los elementos del menú.
OK Utilícela para acceder a grupos de parámetros opara activar una selección.
Luz Indicación Función
Verde ON La luz de encendido se activa
cuando el convertidor defrecuencia recibe potencia de latensión de red a través de un
terminal de bus de CC o de laalimentación externa de 24 V.
Amarillo WARN Cuando se cumplen lascondiciones de advertencia, la luzde advertencia amarilla seenciende y aparece un texto en lapantalla que identifica elproblema.
Rojo ALARM Un fallo hace que la luz de alarmaroja parpadee y aparezca un textode alarma.
5.1.5 Teclas de funcionamiento
Las teclas de funcionamiento están en la parte inferior delteclado.
Tecla FunciónHand Púlsela para arrancar el convertidor de frecuencia
en control local.
• Utilice las teclas de navegación para controlarla velocidad del convertidor de frecuencia.
• Una señal de parada externa emitida por laentrada de control o comunicación serieinvalida la tecla [Hand] local.
Off Detiene el motor pero no desconecta la potencia
del convertidor de frecuencia.
Interfaz de usuario Guía rápida del AF-600 FP
DET-759A/S 21
5 5
Tecla FunciónAuto Pone el sistema en modo de funcionamiento
remoto.
• Responde a un comando de arranque externoemitido por los terminales de control ocomunicación serie.
• La referencia de velocidad procede de unafuente externa.
Reset Reinicia el convertidor de frecuenciamanualmente una vez se ha eliminado un fallo.
5.2 Copias de seguridad y copias de losajustes de parámetros
Los datos de programación se almacenan internamente enel convertidor de frecuencia.
• Los datos pueden cargarse en la memoria delteclado como copia de seguridad de almacena-miento.
• Una vez almacenados en el teclado, los datospueden descargarse de nuevo en el convertidorde frecuencia.
• Los datos también se pueden descargar en otrosconvertidores de frecuencia conectándoles elteclado y descargando los ajustes almacenados.(Esta es la manera rápida de programar variasunidades con los mismos ajustes.)
• La inicialización del convertidor de frecuenciapara restaurar los ajustes predeterminados defábrica no cambia los datos almacenados en lamemoria del teclado.
ADVERTENCIA¡ARRANQUE ACCIDENTAL!Cuando el convertidor de frecuencia se conecta a la red deCA, el motor puede arrancar en cualquier momento. Elconvertidor de frecuencia, el motor y cualquier equipoaccionado deben estar listos para funcionar. En casocontrario, podrían causarse lesiones personales o incluso lamuerte, así como daños al equipo u otros objetos.
5.2.1 Cargar datos al teclado
1. Pulse [OFF] (Desactivado) para detener el motorantes de cargar o descargar datos.
2. Vaya a K-50 Copia Teclado.
3. Pulse [OK].
4. Seleccione Todos al teclado.
5. Pulse [OK]. Una barra de progreso muestra elprogreso de carga.
6. Pulse [Hand] (Manual) o [Auto] (Automático) paravolver al funcionamiento normal.
5.2.2 Descargar datos desde el teclado
1. Pulse [OFF] (Desactivado) para detener el motorantes de cargar o descargar datos.
2. Vaya a K-50 Copia Teclado.
3. Pulse [OK].
4. Seleccione Todos desde el teclado.
5. Pulse [OK]. Una barra de progreso muestra elproceso de descarga.
6. Pulse [Hand] (Manual) o [Auto] (Automático) paravolver al funcionamiento normal.
5.3 Restablecimiento de los ajustespredeterminados
PRECAUCIÓNLa inicialización restaura la unidad a los ajustes predeter-minados de fábrica. Todos los registros de programación,datos de motor, ubicación y monitorización se perderán. Sicarga los datos al teclado, dispondrá de una copia deseguridad antes de la inicialización.
La restauración de los ajustes de parámetros delconvertidor de frecuencia a los valores predeterminados selleva a cabo a través de la inicialización del convertidor defrecuencia. La inicialización puede efectuarse a través deH-03 Restaurar ajustes de fábrica o manualmente.
• La inicialización empleando H-03 Restaurar ajustesde fábrica no cambia los datos del convertidor defrecuencia, como las horas de funcionamiento, lasselecciones de comunicación serie, los ajustespersonales del menú, el registro de fallos, elregistro de alarmas y otras funciones de monitori-zación.
• Se recomienda el uso de H-03 Restaurar ajustes defábrica.
• La inicialización manual elimina todos los datosdel motor, programación, ubicación y monitori-zación y restaura los ajustes predeterminados defábrica.
5.3.1 Inicialización recomendada
1. Pulse [Main Menu] (Menú principal) dos vecespara acceder a los parámetros.
2. Desplácese hasta H-03 Restaurar ajustes de fábrica.
3. Pulse [OK].
Interfaz de usuario Guía rápida del AF-600 FP
22 DET-759A/S
55
4. Avance hasta [2] Restaurar ajustes de fábrica.
5. Pulse [OK] (Aceptar).
6. Apague la alimentación de la unidad y espere aque el display se apague.
7. Encienda la alimentación de la unidad.
Los ajustes predeterminados de los parámetros serestauran durante el arranque. Esto puede llevar algo másde tiempo de lo normal.
8. Se muestra la alarma 80.
9. Pulse [Reset] (Reinicio) para volver al modo defuncionamiento.
5.3.2 Inicialización manual
1. Apague la alimentación de la unidad y espere aque el display se apague.
2. Mantenga pulsadas las teclas [Status] (Estado),[Main Menu] (Menú principal) y [OK] (Aceptar) almismo tiempo mientras enciende la unidad.
Los ajustes predeterminados de fábrica de los parámetrosse restablecen durante el arranque. Esto puede llevar algomás de tiempo de lo normal.
Con la inicialización manual no se efectúa unreinicio de lasiguiente información del convertidor de frecuencia.
• ID-00 Horas de funcionamiento
• ID-03 Arranques
• ID-04 Sobretemperat.
• ID-05 Sobretensión
Interfaz de usuario Guía rápida del AF-600 FP
DET-759A/S 23
5 5
6.1.1 Estructura del menú principalK-
## A
just
e te
clad
oK-
37 T
exto
dis
play
1K-
8# L
ect.
día
s+fe
cha/
hora
F-2#
Fun
dam
enta
l 2E-
## E
/S d
igita
l
K-0#
Aju
stes
bás
icos
tecl
ado
K-38
Tex
to d
ispl
ay 2
K-81
Día
s la
bora
bles
F-24
Tie
mpo
man
teni
doE-
0# E
ntra
das
digi
tale
s
K-01
Idio
ma
K-39
Tex
to d
ispl
ay 3
K-82
Día
s la
bora
bles
adi
cion
ales
F-26
Rui
do m
otor
(Fre
c. p
orta
dora
)E-
00 M
odo
E/S
dig
ital
K-02
Uni
dad
de
velo
cida
d d
e m
otor
K-4#
Bot
ones
tec
lado
K-83
Día
s no
labo
rabl
es
adic
iona
les
F-27
Ton
o m
otor
ale
ator
ioE-
01 T
erm
inal
18
entr
ada
digi
tal
K-03
Aju
stes
regi
onal
esK-
40 B
otón
[Han
d] d
el t
ecla
doK-
89 F
echa
y h
ora
F-3#
Fun
dam
enta
l 3E-
02 T
erm
inal
19
entr
ada
digi
tal
K-04
Est
ado
ope
raci
ón e
n a
rran
que
K-41
Bot
ón [O
ff] d
el t
ecla
doF-
## P
arám
etro
s fu
ndam
enta
les
F-37
Pat
rón
con
mut
ació
n a
vanz
.E-
03 T
erm
inal
27
entr
ada
digi
tal
K-05
Uni
dad
de
mod
o lo
cal
K-42
Bot
ón [A
uto]
del
tec
lado
F-0#
Fun
dam
enta
l 0F-
38 S
obre
mod
ulac
ión
E-04
Ter
min
al 2
9 en
trad
a di
gita
l
K-1#
Ope
rac.
aju
ste
tecl
ado
K-43
Bot
ón [R
eset
] de
l tec
lado
F-01
Aju
ste
frec
uenc
ia 1
F-4#
Fun
dam
enta
l 4E-
05 T
erm
inal
32
entr
ada
digi
tal
K-10
Aju
ste
activ
oK-
5# C
opia
r/G
uard
arF-
02 M
étod
o fu
ncio
nam
ient
oF-
40 L
imita
dor
de p
ar (f
unci
onam
.)E-
06 T
erm
inal
33
entr
ada
digi
tal
K-11
Edi
tar
ajus
teK-
50 C
opia
Tec
lado
F-03
Fre
cuen
cia
salid
a m
áx. 1
F-41
Lím
ite d
e pa
r (fr
enad
o)E-
1# R
ampa
s ac
el./d
ecel
. adi
cion
ales
K-12
Aju
ste
actu
al e
nlaz
ado
aK-
51 C
opia
de
ajus
teF-
04 F
recu
enci
aF-
43 L
ímite
inte
nsid
adE-
10 T
iem
po a
cel 2
K-13
Lec
tura
: Aju
stes
rela
cion
ados
K-6#
Pro
tecc
ión
por
con
tras
eña
F-05
Ten
sión
nom
inal
del
mot
orF-
5# R
efs
ampl
iada
sE-
11 T
iem
po d
ecel
2
K-14
Lec
tura
: edi
tar
ajus
tes
/ Ca
nal
K-60
Con
tras
eña
men
ú p
rinci
pal
F-07
Tie
mpo
ace
l 1F-
52 R
efer
enci
a m
ínim
aE-
2# S
alid
as d
igita
les
K-2#
Dis
play
tec
lado
K-61
Acc
eso
a m
enú
prin
c. s
in
cont
rase
ñaF-
08 T
iem
po d
ecel
1F-
53 R
efer
enci
a m
áxim
aE-
20 S
alid
a di
gita
l ter
min
al 2
7
K-20
Lín
ea d
e pa
ntal
la p
eque
ña 1
.1K-
65 C
ontr
aseñ
a M
enú
rápi
doF-
1# F
unda
men
tal 1
F-54
Fun
ción
de
refe
renc
iaE-
21 S
alid
a di
gita
l ter
min
al 2
9
K-21
Lín
ea d
e pa
ntal
la p
eque
ña 1
.2K-
66 A
cces
o a
men
ú r
ápid
o s
inco
ntra
seña
F-10
Sob
reca
rga
elec
trón
ica
F-6#
Ref
eren
cias
E-24
Rel
é de
func
ión
K-22
Lín
ea d
e pa
ntal
la p
eque
ña 1
.3K-
7# A
just
es d
el r
eloj
F-11
Ven
t. ex
tern
o m
otor
F-64
Ref
eren
cia
inte
rna
rela
tiva
E-26
Ret
ardo
con
ex.,
relé
K-23
Lín
ea d
e pa
ntal
la g
rand
e 2
K-70
Fec
ha y
hor
aF-
12 E
ntra
da te
rmis
tor
mot
orF-
9# P
oten
cióm
. dig
ital
E-27
Ret
ardo
des
cone
x, r
elé
K-24
Lín
ea d
e pa
ntal
la g
rand
e 3
K-71
For
mat
o d
e fe
cha
F-15
Lím
ite a
lto v
eloc
. mot
or[H
z]F-
90 T
amañ
o d
e pa
soE-
5# M
odo
E/S
/ E
/S a
dici
onal
K-25
Arr
anqu
e rá
pido
K-72
For
mat
o d
e ho
ra
F-16
Lím
ite b
ajo
vel
oc. m
otor
[Hz]
F-91
Tie
mpo
ace
l./de
cel.
E-51
Ter
min
al 2
7 m
odo
E/S
K-3#
Lec
tura
per
sona
lizad
aK-
74 H
orar
io d
e ve
rano
F-17
Lím
ite a
lto v
eloc
. mot
or
[RPM
]F-
92 R
estit
ució
n d
e En
ergí
aE-
52 T
erm
inal
29
mod
o E
/S
K-30
Uni
dad
par
a le
ctur
a pe
rson
aliz
.K-
76 In
icio
del
hor
ario
de
vera
noF-
18 L
ímite
baj
o v
eloc
. mot
or[R
PM]
F-93
Lím
ite m
áxim
oE-
53 T
erm
inal
X30
/2 e
ntra
da d
igita
l
K-31
Val
or m
ínim
o d
e le
ctur
a pe
rson
a-liz
ada
K-77
Fin
del
hor
ario
de
vera
no
F-94
Lím
ite m
ínim
oE-
54 T
erm
inal
X30
/3 e
ntra
da d
igita
l
K-32
Val
or m
áxim
o d
e le
ctur
a pe
rson
a-liz
ada
K-79
Fal
lo d
e re
loj
F-
95 A
cel./
dece
l. re
tard
o d
e ra
mpa
E-55
Ter
min
al X
30/4
ent
rada
dig
ital
Sobre la programación Guía rápida del AF-600 FP
24 DET-759A/S
66
E-56
Sal
. dig
. ter
m. X
30/6
(OPC
GPI
O)
E-96
Tie
mpo
lím
. pre
det.
salid
a pu
lsos
#29
P-07
Pot
enci
a m
otor
[kW
]H
-5#
Aj.
inde
p. c
arga
AN
-1#
Entr
ada
anal
ógic
a 53
E-57
Sal
. dig
. ter
m. X
30/7
(OPC
GPI
O)
E-97
Con
trol
de
bus
salid
a de
pul
sos
#X30
/6P-
08 C
ompr
ob. r
otac
ión
mot
orH
-58
Flys
tart
Tes
t Pu
lses
Cur
rent
AN
-10
Term
inal
53
esca
la b
aja
V
E-6#
Ent
rada
de
puls
osE-
98 T
. lím
. pre
det.
sal.
puls
os #
X30/
6P-
09 C
ompe
nsac
ión
des
lizam
.H
-59
Flys
tart
Tes
t Pu
lses
Fre
quen
cyA
N-1
1 Te
rmin
al 5
3 es
cala
alta
V
E-60
Ter
m. 2
9 ba
ja fr
ecue
ncia
C-##
Fun
cion
es c
ontr
ol fr
ecue
ncia
P-10
Tie
mpo
com
pens
. des
lizam
.
cons
tant
eH
-6#
Aj.
depe
nd. c
arga
AN
-12
Term
inal
53
esca
la b
aja
mA
E-61
Ter
m. 2
9 al
ta fr
ecue
ncia
C-0#
Fun
cion
es c
ontr
ol fr
ecue
ncia
P-3#
Dat
os a
vanz
. mot
orH
-64
Am
ortig
uaci
ón d
e re
sona
ncia
AN
-13
Term
inal
53
esca
la a
lta m
A
E-62
Ter
m. 2
9 va
lor
bajo
ref.
/rea
lim.
C-01
Sal
to d
e fr
ecue
ncia
des
de [H
z]P-
30 R
esis
tenc
ia e
stát
or (R
s)H
-65
Cons
t. tie
mpo
am
ortig
ua. d
ere
sona
ncia
AN
-14
Term
. 53
valo
r ba
jo r
ef. /
real
im.
E-63
Ter
m. 2
9 va
lor
alto
ref
. /re
alim
.C-
02 V
eloc
idad
byp
ass
desd
e [R
PM]
P-31
Res
iste
ncia
roto
r (R
r)H
-7#
Aju
ste
Adv
ert.
AN
-15
Term
. 53
valo
r al
to r
ef. /
real
im.
E-64
Tie
mpo
filtr
o p
ulso
s co
nsta
nte
#29
C-03
Vel
ocid
ad b
ypas
s ha
sta
[RPM
]P-
35 R
eact
anci
a pr
inc.
(Xh)
H-7
0 A
dver
t. in
tens
. baj
aA
N-1
6 Te
rmin
al 5
3 tie
mpo
filtr
oco
nsta
nte
E-65
Ter
m. 3
3 ba
ja fr
ecue
ncia
C-04
Sal
to d
e fr
ecue
ncia
a [H
z]P-
36 R
esis
tenc
ia p
érdi
da h
ierr
o (R
fe)
H-7
1 A
dver
t. in
tens
. alta
AN
-17
Term
inal
53
cero
act
ivo
E-66
Ter
m. 3
3 al
ta fr
ecue
ncia
C-05
Fre
cuen
cia
mul
tiaju
ste
1 -
8H
-##
Pará
met
ros
de a
lto re
ndim
ient
oH
-72
Adv
ert.
vel
oc. b
aja
AN
-2#
Entr
ada
anal
ógic
a 54
E-67
Ter
m. 3
3 va
lor
bajo
ref.
/rea
lim.
C-2#
Aju
ste
Velo
c. fi
jaH
-0#
Func
. alto
ren
dim
.H
-73
Adv
ert.
vel
oc. a
ltaA
N-2
0 Te
rmin
al 5
4 es
cala
baj
a V
E-68
Ter
m. 3
3 va
lor
alto
ref.
/rea
lim.
C-20
Vel
ocid
ad fi
ja [H
z]H
-03
Rest
aura
r aj
uste
s de
fábr
ica
H-7
4 A
dver
tenc
ia re
fere
ncia
baj
aA
N-2
1 Te
rmin
al 5
4 es
cala
alta
V
E-69
Tie
mpo
filtr
o p
ulso
s co
nsta
nte
#33
C-21
Vel
ocid
ad fi
ja [R
PM]
H-0
4 D
esc.
rei
nic.
aut
om.
H-7
5 A
dver
tenc
ia re
fere
ncia
alta
AN
-22
Term
inal
54
esca
la b
aja
mA
E-7#
Sal
ida
puls
osC-
22 T
iem
po v
eloc
. fija
ace
l./de
cel.
H-0
5 Re
inic
. aut
om. (
Inte
rv. r
ein.
)H
-76
Adv
erte
ncia
real
imen
taci
ón b
aja
AN
-23
Term
inal
54
esca
la a
lta m
A
E-70
Ter
min
al 2
7 sa
lida
puls
os v
aria
ble
C-3#
Aju
stes
de
frec
uenc
ia 2
y 3
H-0
6 Fu
nc. v
entil
ador
H-7
7 A
dver
tenc
ia re
alim
enta
ción
alta
AN
-24
Term
. 54
valo
r ba
jo r
ef. /
real
im.
E-71
Fre
c. m
áx. s
alid
a de
pul
sos
#27
C-30
Com
ando
de
frec
uenc
ia 2
H-0
8 Bl
oque
o in
vers
ión
H-7
8 Fu
nció
n fa
llo fa
se m
otor
AN
-25
Term
. 54
valo
r al
to r
ef. /
real
im.
E-72
Ter
min
a 29
sal
ida
puls
os v
aria
ble
C-34
Com
ando
de
frec
uenc
ia 3
H-0
9 A
rran
que
H-8
# A
just
es d
e pa
rada
AN
-26
Term
inal
54
tiem
po fi
ltro
cons
tant
e
E-74
Fre
c. m
áx. s
alid
a de
pul
sos
#29
C-4#
Aj.
salto
frec
. sem
iaut
.H
-3#
Velo
cida
d d
e pa
rada
H-8
0 Fu
nció
n d
e pa
rada
AN
-27
Term
inal
54
cero
act
ivo
E-75
Ter
min
al X
30/6
var
. sal
ida
puls
osC-
40 A
j sal
to fr
ec s
emia
utH
-36
Velo
cida
d b
aja
desc
onex
ión
[RPM
]H
-81
Vel.
mín
. par
a fu
nc. p
arad
a [R
PM]
AN
-3#
Entr
ada
anal
ógic
a X3
0/11
E-76
Fre
c. m
áx. s
alid
a de
pul
sos
#X30
/6P-
## D
atos
mot
orH
-37
Velo
cida
d b
aja
desc
onex
ión
[Hz]
H-8
2 Ve
l. m
ín. p
ara
func
. par
ada
[Hz]
AN
-30
Term
inal
X30
/11
baja
tens
ión
E-9#
Con
trol
ado
por
bus
P-0#
Dat
os m
otor
H-4
# A
just
es a
vanz
ados
AN
-##
E/S
anal
ógic
aA
N-3
1 Te
rmin
al X
30/1
1 al
ta te
nsió
n
E-90
Con
trol
de
bus
digi
tal y
de
relé
P-02
Pot
enci
a m
otor
[CV]
H-4
0 M
odo
Con
figur
ació
nA
N-0
# M
odo
E/S
ana
lógi
co
AN
-34
Term
. X30
/11
valo
r ba
jo re
f. /
real
im.
E-93
Con
trol
de
bus
salid
a de
pul
sos
#27
P-03
Inte
nsid
ad d
el m
otor
H-4
3 Ca
ract
erís
ticas
de
par
AN
-00
Tiem
po L
ímite
Cer
o A
ctiv
oA
N-3
5 Te
rm. X
30/1
1 va
lor
alto
ref
. /re
alim
.
E-94
Tie
mpo
lím
. pre
det.
sal
ida
puls
os#2
7P-
04 A
utoa
just
eH
-48
Cloc
kwis
e D
irect
ion
AN
-01
Func
ión
Cer
o A
ctiv
oA
N-3
6 Te
rm. t
erm
inal
X30
/11
E-95
Con
trol
de
bus
salid
a de
pul
sos
#29
P-06
Vel
ocid
ad b
ásic
a
AN
-02
Func
ión
Cer
o A
ctiv
o e
n m
odo
ince
ndio
AN
-37
Term
. X30
/11
cero
act
ivo
Sobre la programación Guía rápida del AF-600 FP
DET-759A/S 25
6 6
AN
-4#
Entr
ada
anal
ógic
a X3
0/12
SP-#
# Fu
ncio
nes
espe
cial
esSP
-5#
Am
bien
teO
-13
Códi
go d
e es
tado
conf
igur
able
STW
O-8
# D
iagn
óstic
o p
uert
o c
onve
rtid
or
AN
-40
Term
inal
X30
/12
baja
tens
ión
SP-1
# Lí
nea
On/
Off
SP-5
0 Fi
ltro
RFI
O-3
# Co
nfig
urac
ión
del
pue
rto
del
conv
ertid
orO
-80
Cont
ador
men
saje
s de
bus
AN
-41
Term
inal
X30
/12
alta
tens
ión
SP-1
0 Fa
llo d
e al
imen
taci
ón d
e re
dSP
-51
DC
Lin
k Co
mpe
nsat
ion
O-3
0 Pr
otoc
olo
O-8
1 Co
ntad
or e
rror
es d
e bu
s
AN
-44
Term
. X30
/12
valo
r ba
jo re
f. /
real
im.
SP-1
1 Fa
llo e
n e
ntra
da t
ensi
ón d
e re
dSP
-53
Mon
itor
del v
entil
ador
O-3
1 D
irecc
ión
O-8
2 M
ensa
jes
de e
scla
vo re
cibi
dos
AN
-45
Term
. X30
/12
valo
r al
to r
ef. /
real
im.
SP-1
2 Fu
nció
n d
eseq
uil.
línea
SP-5
5 O
utpu
t Fi
lter
O-3
2 Ve
loc.
bau
dios
pue
rto
con
v.O
-83
Cont
ador
err
ores
de
escl
avo
AN
-46
Term
. X30
/12
cons
t. tie
mpo
filtr
oSP
-2#
Func
ione
s de
rese
tSP
-59
Act
ual N
umbe
r of
Inve
rter
Uni
tsO
-33
Parid
ad d
e pu
erto
con
vert
.O
-89
Cuen
ta d
e di
agnó
stic
os
AN
-47
Term
. X30
/12
cero
act
ivo
SP-2
3 A
just
e de
cód
igo
des
crip
tivo
SP-6
# Re
ducc
ión
aut
omát
ica
O-3
4 Es
timat
ed c
ycle
tim
eO
-9#
Vel.
fija
del b
us /
Rea
limen
taci
ón
AN
-5#
Salid
a an
alóg
ica
42SP
-25
Reta
rdo
des
con.
con
lím
. de
par
SP-6
0 Fu
ncio
nam
ient
o c
onso
bret
emp.
O-3
5 Re
tard
o re
spue
sta
mín
.O
-90
Velo
c Bu
s Jo
g 1
AN
-50
Term
inal
42
salid
aSP
-26
Ret.
de d
esc.
en
fallo
del
con
vert
.
SP-6
1 Fu
nció
n c
on c
onve
rt.
sobr
ecar
g.O
-36
Reta
rdo
resp
uest
a m
áx.
O-9
1 Ve
loc
Bus
Jog
2
AN
-51
Term
inal
42
salid
a es
c. m
ín.
SP-2
8 A
j. pr
oduc
ción
SP-6
2 Co
rrie
nte
redu
c. c
onve
rt.
sobr
ecar
g.O
-37
Reta
rdo
máx
. int
erca
rac.
O-9
4 Re
alim
enta
ción
de
bus
1
AN
-52
Term
inal
42
salid
a es
c. m
áx.
SP-2
9 Có
digo
de
serv
icio
O-#
# O
pcio
nes
/ Co
mun
ic.
O-4
# Co
nf. p
rot.
MC
con
v.O
-95
Real
im. d
e bu
s 2
AN
-53
Term
inal
42
cont
rol b
us d
e sa
lida
SP-3
# Ct
rl. lí
m. i
nten
s.O
-0#
Aju
stes
gen
eral
esO
-40
Sele
cció
n d
e te
legr
ama
O-9
6 Re
alim
. de
bus
3
AN
-54
Term
inal
42
Tiem
po lí
m. s
alid
apr
edet
.SP
-30
Ctro
l. lím
. int
ens.
, Gan
anci
a pr
opor
c.O
-01
Pues
to d
e co
ntro
lO
-42
Conf
ig. e
scrit
ura
PCD
AO
-##
Opc
ión
E/S
ana
lógi
ca
AN
-6#
Salid
a an
alóg
ica
X30/
8SP
-31
Cont
rol l
ím. i
nten
., Ti
empo
inte
grac
.O
-02
Fuen
te c
ódig
o c
ontr
olO
-43
Conf
ig. l
ectu
ra P
CDA
O-0
# M
odo
E/S
ana
lógi
co
AN
-60
Term
inal
X30
/8 s
alid
aSP
-32
Curr
ent
Lim
Ctr
l, Fi
lter
Tim
e
O-0
3 Va
lor
de t
iem
po lí
mite
cód
.
ctrl.
O-5
# D
igita
l/Bus
AO
-00
Mod
o T
erm
inal
X42
/1
AN
-61
Term
inal
X30
/8 e
scal
a m
inSP
-4#
Aho
rro
ene
rgét
ico
O-0
4 Fu
nció
n ti
empo
lím
ite c
ód.
ctrl.
O-5
0 Se
lecc
ión
iner
cia
AO
-01
Mod
o T
erm
inal
X42
/3
AN
-62
Term
inal
X30
/8 e
scal
a m
inSP
-40
Niv
el V
TO
-05
Func
ión
tiem
po lí
mite
O-5
2 Se
lecc
ión
fren
o C
CA
O-0
2 M
odo
Ter
min
al X
42/5
AN
-63
Term
inal
X30
/8 c
ontr
ol b
us d
esa
lida
SP-4
1 A
horr
o e
nerg
étic
o a
horr
o e
nerg
íaO
-06
Rein
icia
r si
tiem
po lí
mite
cód.
ctr
l.O
-53
Sele
c. a
rran
que
AO
-1#
Entr
ada
anal
ógic
a X4
2/1
AN
-64
Term
. X30
/8 T
. lím
. sal
ida
pred
et.
SP-4
2 A
horr
o e
nerg
étic
o F
recu
enci
aO
-07
Acc
iona
dor
diag
nóst
ico
O-5
4 Se
lec.
sen
tido
inve
rso
AO
-10
Term
inal
X42
/1 b
aja
tens
ión
SP
-43
Cosp
hi d
el m
otor
O-1
# A
just
es d
e co
ntro
lO
-55
Sele
c. a
just
eA
O-1
1 Te
rmin
al X
42/1
alta
ten
sión
O-1
0 Tr
ama
del c
ódig
o d
e co
ntro
lO
-56
Sele
c. r
efer
enci
a in
tern
a
AO
-14
Term
. X42
/1 v
alor
baj
o re
f. /
real
im.
Sobre la programación Guía rápida del AF-600 FP
26 DET-759A/S
66
AO
-15
Term
. X42
/1 v
alor
alto
ref.
/rea
lim.
AO
-6#
Salid
a an
alóg
ica
X42/
11PB
-94
Pará
met
ros
cam
biad
os (5
)EN
-33
CIP
Revi
sion
BN-7
3 M
áx. t
ram
as in
fo M
S/TP
AO
-16
Term
. X42
/1 c
onst
. tie
mpo
filtr
oA
O-6
0 Te
rmin
al X
42/1
1 sa
lida
EN-#
# Et
hern
etEN
-34
CIP
Prod
uct
Code
BN-7
4 "S
tart
up I
am"
AO
-17
Term
. X42
/1 c
ero
act
ivo
AO
-61
Term
inal
X42
/11
esca
la m
inEN
-0#
Aju
stes
de
IPEN
-8#
Otr
os s
ervi
cios
Eth
erne
tBN
-75
Cont
rase
ña in
icia
lizac
.
AO
-2#
Entr
ada
anal
ógic
a X4
2/3
AO
-62
Term
inal
X42
/11
esca
la m
inEN
-00
IP A
ddre
ss A
ssig
nmen
tEN
-80
FTP
Serv
erD
N-#
# Bu
s de
cam
po D
evic
eNet
AO
-21
Term
inal
X42
/3 a
lta te
nsió
nA
O-6
3 Te
rmin
al X
42/1
1 co
ntro
l bus
de
salid
aEN
-01
IP A
ddre
ssEN
-81
HTT
P Se
rver
DN
-0#
Aju
stes
com
unes
AO
-21
Term
inal
X42
/3 a
lta te
nsió
nA
O-6
4 Te
rm. X
42/1
1 T.
lím
. sal
ida
pred
et.
EN-0
2 Su
bnet
Mas
kEN
-82
SMTP
Ser
vice
DN
-00
Prot
ocol
o D
evic
eNet
.
AO
-24
Term
. X42
/3 v
alor
baj
o re
f. /r
ealim
.PB
-##
Prof
ibus
EN-0
3 D
efau
lt G
atew
ayEN
-89
Tran
spar
ent
Sock
etCh
anne
l Por
tD
N-0
1 Se
lecc
. vel
oc. e
n b
audi
os
AO
-25
Term
. X42
/3 v
alor
alto
ref.
/rea
lim.
PB-1
5 Co
nfig
. esc
ritur
a PC
DEN
-04
DH
CP S
erve
rEN
-9#
Serv
icio
s Et
hern
etav
anza
dos
DN
-02
ID M
AC
AO
-26
Term
. X42
/3 c
onst
. tie
mpo
filtr
oPB
-16
Conf
ig. l
ectu
ra P
CDEN
-05
Leas
e Ex
pire
sEN
-90
Cabl
e D
iagn
ostic
DN
-05
Lect
ura
cont
ador
err
ores
tran
sm.
AO
-27
Term
. X42
/3 c
ero
act
ivo
PB-1
8 D
irecc
ión
de
nodo
EN-0
6 N
ame
Serv
ers
EN-9
1 M
DI-X
DN
-06
Lect
ura
cont
ador
err
ores
rece
pció
n
AO
-3#
Entr
ada
anal
ógic
a X4
2/5
PB-2
2 Se
lecc
ión
de
tele
gram
aEN
-07
Dom
ain
Nam
eEN
-92
IGM
P Sn
oopi
ngD
N-0
7 Le
ctur
a co
ntad
or b
us d
esac
.
AO
-30
Term
inal
X42
/5 b
aja
tens
ión
PB-2
3 Pa
rám
etro
s pa
ra s
eñal
esEN
-08
Hos
t N
ame
EN-9
3 Ca
ble
Erro
r Le
ngth
DN
-1#
Dev
iceN
et
AO
-31
Term
inal
X42
/5 a
lta te
nsió
nPB
-27
Edit.
par
ámet
ros
EN-0
9 Ph
ysic
al A
ddre
ssEN
-94
Broa
dcas
t St
orm
Prot
ectio
nD
N-1
0 Se
lecc
ión
tip
o d
e da
tos
proc
eso
AO
-34
Term
. X42
/5 v
alor
baj
o re
f. /r
ealim
.PB
-28
Cont
rol d
e pr
oces
oEN
-1#
Pará
met
ros
de e
nlac
e Et
hern
etEN
-95
Broa
dcas
t St
orm
Filt
erD
N-1
1 Es
critu
ra c
onfig
. dat
os p
roce
so
AO
-35
Term
. X42
/5 v
alor
alto
ref.
/rea
lim.
PB-5
3 Có
digo
de
adve
rten
cia
de
Prof
ibus
EN-1
0 Li
nk S
tatu
sEN
-98
Inte
rfac
e Co
unte
rsD
N-1
2 Le
ctur
a co
nfig
. dat
os p
roce
so
AO
-36
Term
. X42
/5 c
onst
. tie
mpo
filtr
oPB
-63
Velo
cida
d r
eal e
n b
audi
osEN
-11
Link
Dur
atio
nEN
-99
Med
ia C
ount
ers
DN
-13
Pará
met
ro d
e ad
vert
enci
a
AO
-37
Term
. X42
/5 c
ero
act
ivo
PB-7
0 Ed
itar
ajus
teEN
-12
Aut
o N
egot
iatio
nLN
-##
LON
WO
RKS
DN
-14
Refe
renc
ia d
e re
d
AO
-4#
Salid
a an
alóg
ica
X42/
7PB
-71
Gra
bar
valo
res
de d
atos
EN-1
3 Li
nk S
peed
LN-0
# ID
de
LonW
orks
DN
-15
Cont
rol d
e re
d
AO
-40
Term
inal
X42
/7 s
alid
aPB
-72
Rein
icia
r un
idad
Pro
fibus
EN-1
4 Li
nk D
uple
xLN
-00
ID d
e N
euro
nD
N-2
# Fi
ltros
CO
S
AO
-41
Term
inal
X42
/7 e
scal
a m
in9-
75 D
O Id
entif
icat
ion
EN-2
# D
atos
de
proc
eso
LN-1
# Fu
ncio
nes
LON
DN
-20
Filtr
o C
OS
1
AO
-42
Term
inal
X42
/7 e
scal
a m
inPB
-80
Pará
met
ros
defin
idos
(1)
EN-2
0 Co
ntro
l Ins
tanc
eLN
-10
Perf
il de
uni
dad
DN
-21
Filtr
o C
OS
2
AO
-43
Term
inal
X42
/7 c
ontr
ol b
us d
esa
lida
PB-8
1 Pa
rám
etro
s de
finid
os (2
)EN
-21
Proc
ess
Dat
a Co
nfig
Writ
eLN
-15
Cód.
de
adve
rten
cia
LON
DN
-22
Filtr
o C
OS
3
AO
-44
Term
. X42
/7 T
. lím
. sal
ida
pred
et.
PB-8
2 Pa
rám
etro
s de
finid
os (3
)EN
-22
Proc
ess
Dat
a Co
nfig
Rea
dLN
-17
Revi
sión
XIF
DN
-23
Filtr
o C
OS
4
AO
-5#
Salid
a an
alóg
ica
X42/
9PB
-83
Pará
met
ros
defin
idos
(4)
EN-2
8 St
ore
Dat
a Va
lues
LN-1
8 Re
visi
ón L
onW
orks
DN
-3#
Acc
eso
par
ám.
AO
-50
Term
inal
X42
/9 s
alid
aPB
-84
Pará
met
ros
defin
idos
(5)
EN-2
9 St
ore
Alw
ays
LN-2
# Pa
rám
. LO
N A
cces
oD
N-3
0 Ín
dice
Mat
riz
AO
-51
Term
inal
X42
/9 e
scal
a m
inPB
-90
Pará
met
ros
cam
biad
os (1
)EN
-3#
Ethe
rNet
/IPLN
-21
Gra
bar
valo
res
de d
atos
DN
-31
Gra
bar
valo
res
de d
atos
AO
-52
Term
inal
X42
/9 e
scal
a m
inPB
-91
Pará
met
ros
cam
biad
os (2
)EN
-30
War
ning
Par
amet
erBN
-##
BACn
etD
N-3
2 Re
visi
ón D
evic
enet
AO
-53
Term
inal
X42
/9 c
ontr
ol b
us d
esa
lida
PB-9
2 Pa
rám
etro
s ca
mbi
ados
(3)
EN-3
1 N
et R
efer
ence
BN-7
0 In
stan
cia
BACn
etD
N-3
3 A
lmac
enar
sie
mpr
e
AO
-54
Term
. X42
/9 T
. lím
. sal
ida
pred
et.
PB-9
3 Pa
rám
etro
s ca
mbi
ados
(4)
EN-3
2 N
et C
ontr
olBN
-72
Máx
. mae
st. M
S/TP
DN
-34
Códi
go d
e pr
oduc
to D
evic
eNet
Sobre la programación Guía rápida del AF-600 FP
DET-759A/S 27
6 6
ID-#
# In
form
ació
n d
el c
onve
rtid
orID
-42
máx
ima
DR-
12 T
ensi
ón n
omin
al d
el m
otor
DR-
6# E
ntra
das
y sa
lidas
DR-
95 C
ódig
o d
e es
tado
am
pl. 2
ID-0
# D
atos
func
.ID
-43
Vers
ión
de
soft
war
eD
R-13
Fre
cuen
cia
DR-
60 E
ntra
da d
igita
lD
R-96
Cód
igo
man
teni
mie
nto
ID-0
0 H
oras
de
func
iona
mie
nto
ID-4
4 N
úmer
o d
e m
odel
o G
ED
R-14
Inte
nsid
ad d
el m
otor
DR-
61 A
just
e in
terr
upto
rte
rmin
al 5
3LG
-##
Regs
.+es
tado
E/S
opc
.
ID-0
1 H
oras
func
iona
m.
ID-4
5 Ca
dena
de
códi
goD
R-15
Fre
cuen
cia
[%]
DR-
62 E
ntra
da a
naló
gica
53
LG-0
# Re
g. m
ante
nim
ient
o
ID-0
2 Co
ntad
or k
Wh
ID-4
6 N
úm. p
rodu
cto
GE
DR-
16 P
ar [N
m]
DR-
63 A
just
e in
terr
upto
rte
rmin
al 5
4LG
-00
Reg.
man
teni
mie
nto:
Ítem
ID-0
3 A
rran
ques
ID-4
7 N
úm. m
odel
o t
arj.
pot.
GE
DR-
17 V
eloc
idad
[RPM
]D
R-64
Ent
rada
ana
lógi
ca 5
4LG
-01
Reg.
man
teni
mie
nto:
Acc
ión
ID-0
4 So
bret
empe
rat.
ID-4
8 N
úmer
o ID
del
tecl
ado
DR-
18 T
érm
ico
mot
orD
R-65
Sal
ida
anal
ógic
a 42
[mA
]LG
-02
Reg.
man
teni
mie
nto:
Hor
a
ID-0
5 So
bret
ensi
ónID
-49
Tarje
ta c
ontr
ol id
SW
DR-
22 P
ar [%
]D
R-66
Sal
ida
digi
tal [
bin]
LG-0
3 Re
g. m
ante
nim
ient
o: F
echa
yho
ra
ID-0
6 Re
inic
iar
cont
ador
kW
hID
-50
Tarje
ta p
oten
cia
id S
WD
R-3#
Est
ado
Driv
e
DR-
67 E
ntra
da fr
ecue
ncia
#29
[Hz]
LG-1
# Re
g. m
odo
Fue
go
ID-0
7 Re
inic
io c
onta
dor
de h
oras
func
iona
m.
ID-5
1 N
úmer
o s
erie
dis
pos.
DR-
30 T
ensi
ón d
e bu
s CC
DR-
68 E
ntra
da fr
ecue
ncia
#33
[Hz]
LG-1
0 Re
g. m
odo
ince
ndio
: Eve
nto
ID-0
8 N
úm. d
e ar
ranq
ues
ID-5
3 N
úmer
o s
erie
tar
jeta
pot
enci
aD
R-32
Ene
rgía
fren
o /
sD
R-69
Sal
ida
puls
os #
27 [H
z]LG
-11
Reg.
mod
o in
cend
io: H
ora
ID-1
# A
just
es t
ende
ncia
dat
osID
-6#
Iden
tific
. opc
ión
DR-
33 E
nerg
ía fr
eno
/ 2
min
DR-
70 S
alid
a pu
lsos
#29
[Hz]
LG-1
2 Re
g. m
odo
ince
ndio
: Fec
ha y
hora
ID-1
0 Te
nden
cias
ID-6
0 O
pció
n in
stal
ada
DR-
34 T
emp.
dis
ipad
orD
R-71
Sal
ida
Relé
[bin
]LG
-3#
Esta
do o
pció
n E
/S
ID-1
1 In
terv
alo
ten
denc
iaID
-61
Vers
ión
SW
opc
ión
DR-
35 T
érm
ico
con
vert
idor
DR-
72 C
onta
dor
ALG
-30
Entr
. ana
lóg.
X42
/1
ID-1
2 Ev
ento
de
disp
aro
ID-6
2 N
.º p
edid
o o
pció
nD
R-36
Inte
ns. n
omin
al c
onve
rt.
DR-
73 C
onta
dor
BLG
-31
Entr
. ana
lóg.
X42
/3
ID-1
3 Te
nden
cias
ID-6
3 N
.º s
erie
opc
ión
DR-
37 In
tens
. máx
. con
vert
.D
R-75
Ent
. ana
lóg.
X30
/11
LG-3
2 En
tr. a
naló
g. X
42/5
ID-1
4 M
uest
ras
ante
s de
dis
p.ID
-9#
Info
rm. p
arám
etro
DR-
38 E
stad
o c
ontr
olad
or ló
gico
DR-
76 E
nt. a
naló
g. X
30/1
2LG
-33
Sal.
anal
. X42
/7 [V
]
ID-2
# Re
gist
ro h
istó
rico
ID-9
2 Pa
rám
etro
s de
finid
osD
R-39
Tem
p. t
arje
ta c
ontr
ol.
DR-
77 S
alid
a an
alóg
ica
X30/
8[m
A]
LG-3
4 Sa
l. an
al. X
42/9
[V]
ID-2
0 Re
gist
ro h
istó
rico:
eve
nto
ID-9
3 Pa
rám
etro
s m
odifi
cado
sD
R-40
Buf
fer
de r
egis
tro
llen
oD
R-8#
Bus
de
cam
po y
pue
rto
conv
.LG
-35
Sal.
anal
. X42
/11
[V]
ID-2
1 Re
gist
ro h
istó
rico:
Val
orD
R-##
Lec
tura
s de
dat
osD
R-43
Tim
ed A
ctio
ns S
tatu
sD
R-80
Fie
ldbu
s CT
W 1
AP-
## P
ar. a
plic
. HVA
C
ID-2
2 Re
gist
ro h
istó
rico:
Tie
mpo
DR-
0# E
stad
o g
ener
alD
R-49
Cur
rent
Fau
lt S
ourc
eD
R-82
Fie
ldbu
s RE
F 1
AP-
0# V
ario
s
ID-2
3 Re
gist
ro h
istó
rico:
Fec
ha y
hor
aD
R-00
Cód
igo
de
cont
rol
DR-
5# R
ef. &
rea
lim.
DR-
84 O
pció
n c
omun
. STW
AP-
00 R
etar
do p
arad
a ex
t.
ID-3
# Re
g. a
larm
aD
R-01
Ref
eren
cia
[Uni
dad]
DR-
50 R
efer
enci
a ex
tern
aD
R-85
Pue
rto
con
vert
idor
CTW
1A
P-2#
Det
ec. f
alta
cau
dal
ID-3
0 Re
g. a
larm
a: C
ódig
o d
e fa
lloD
R-02
Ref
eren
cia
%D
R-52
Rea
limen
taci
ón [U
nida
d]D
R-86
Pue
rto
con
v. R
EF 1
AP-
20 A
just
e au
to b
aja
pote
ncia
ID-3
1 Re
g. a
larm
a: V
alor
DR-
03 C
ódig
o e
stad
oD
R-53
Ref
eren
cia
Dig
i pot
DR-
9# L
ect.
dia
gnós
tico
AP-
21 D
etec
ción
baj
a po
tenc
ia
ID-3
2 Re
g. a
larm
a: h
ora
DR-
05 V
alor
real
prin
c. [%
]D
R-54
Rea
lim. 1
[Uni
dad]
DR-
90 C
ódig
o d
e al
arm
aA
P-22
Det
ecci
ón d
e ba
ja v
eloc
idad
ID-3
3 Re
g. a
larm
a: F
echa
y h
ora
DR-
09 L
ectu
ra p
erso
naliz
ada
DR-
55 R
ealim
. 2 [U
nida
d]D
R-91
Cód
igo
de
alar
ma
2A
P-23
Fun
ción
falta
de
caud
al
ID-4
# Id
. del
con
vert
idor
DR-
1# E
stad
o m
otor
DR-
56 R
ealim
. 3 [U
nida
d]D
R-92
Cód
. de
adve
rten
cia
AP-
24 R
etar
do fa
lta d
e ca
udal
ID-4
0 Ti
po c
onve
rt.
DR-
10 P
oten
cia
[kW
]D
R-58
Sal
ida
PID
[%]
DR-
93 C
ódig
o d
e ad
vert
enci
a 2
AP-
26 F
unci
ón b
omba
sec
a
ID-4
1 Se
cció
n d
e al
imen
taci
ónD
R-11
Pot
enci
a [C
V]
DR-
94 C
ódig
o e
stad
o a
mp.
AP-
27 R
etar
do b
omba
sec
a
Sobre la programación Guía rápida del AF-600 FP
28 DET-759A/S
66
AP-
3# A
j. po
t. fa
lta c
aud.
AP-
73 S
tart
ing
Acc
eler
atio
n T
ime
FB-2
0 Lo
cked
Rot
or F
unct
ion
T-53
Reg
istr
o e
nerg
íaCL
-14
Máx
ima
refe
renc
ia/r
ealim
.
AP-
30 P
oten
cia
sin
cau
dal
AP-
75 P
rote
c. c
iclo
cor
toFB
-21
Lock
ed R
otor
Coe
ffici
ent
1T-
54 R
eini
ciar
regi
stro
ene
rgía
CL-2
0 Fu
nció
n d
e re
alim
.
AP-
31 F
acto
r co
rrec
ción
pot
enci
aA
P-76
Inte
rval
o e
ntre
arr
anqu
esFB
-22
Lock
ed R
otor
Coe
ffici
ent
2T-
6# T
ende
ncia
sCL
-21
Valo
r de
con
sign
a 1
AP-
32 V
eloc
. baj
a [R
PM]
AP-
77 T
iem
po e
jecu
ción
mín
.FB
-23
Lock
ed R
otor
Coe
ffici
ent
3T-
60 V
aria
ble
de t
ende
ncia
CL-2
2 Va
lor
de c
onsi
gna
2
AP-
33 V
eloc
. baj
a [H
z]A
P-8#
Com
pens
ació
n c
auda
lFB
-24
Lock
ed R
otor
Coe
ffici
ent
4T-
61 D
atos
bin
con
tinuo
sCL
-23
Valo
r de
con
sign
a 3
AP-
34 P
oten
cia
velo
c. b
aja
[kW
]A
P-80
Com
pens
ació
n c
auda
lFB
-30
Mis
sing
Mot
or F
unct
ion
T-62
Dat
os b
in t
empo
rizad
osCL
-3#
Conv
. av.
rea
lim.
AP-
35 P
oten
cia
velo
c. b
aja
[CV]
AP-
81 A
prox
imac
ión
cur
va c
uadr
ada-
linea
lFB
-31
Mis
sing
Mot
or C
oeffi
cien
t 1
T-63
Inic
io p
erío
do t
empo
rizad
oCL
-30
Refr
iger
ante
AP-
36 V
eloc
. alta
[RPM
]A
P-82
Cál
culo
pun
to d
e tr
abaj
oFB
-32
Mis
sing
Mot
or C
oeffi
cien
t 2
T-64
Fin
per
íodo
tem
poriz
ado
CL-3
1 Re
frig
er. d
ef. p
or u
suar
io A
1
AP-
37 V
eloc
. alta
[Hz]
AP-
83 V
eloc
idad
sin
cau
dal [
RPM
]FB
-33
Mis
sing
Mot
or C
oeffi
cien
t 3
T-65
Val
or b
in m
ínim
oCL
-32
Refr
iger
. def
. por
usu
ario
A2
AP-
38 P
oten
cia
velo
c. a
lta [k
W]
AP-
84 V
eloc
idad
sin
cau
dal [
Hz]
FB-3
4 M
issi
ng M
otor
Coe
ffici
ent
4
T-66
Rei
nici
ar d
atos
bin
cont
inuo
sCL
-33
Refr
iger
. def
. por
usu
ario
A3
AP-
39 P
oten
cia
velo
c. a
lta [C
V]A
P-85
Vel
ocid
ad p
unto
dis
eño
[RPM
]T-
## F
unc.
tem
por.
T-67
Rei
nici
ar d
atos
bin
tem
poriz
ados
CL-3
4 D
uct
1 A
rea
[m2]
AP-
4# M
odo
repo
soA
P-86
Vel
ocid
ad p
unto
dis
eño
[Hz]
T-0#
Acc
ione
s te
mpo
riz.
T-8#
Con
tado
r re
cupe
r.CL
-35
Duc
t 1
Are
a [in
2]
AP-
40 T
iem
po e
jecu
ción
mín
.A
P-87
Pre
sión
a v
eloc
idad
sin
cau
dal
T-00
Tie
mpo
act
iv.
T-80
Fac
tor
refe
renc
ia p
oten
cia
CL-3
6 D
uct
2 A
rea
[m2]
AP-
41 T
iem
po re
poso
mín
.A
P-88
Pre
sión
a v
eloc
idad
nom
inal
T-01
Acc
ión
act
iv.
T-81
Cos
te e
nerg
étic
oCL
-37
Duc
t 2
Are
a [in
2]
AP-
42 V
eloc
. rei
nici
o [R
PM]
AP-
89 C
auda
l en
pun
to d
e di
seño
T-02
Tie
mpo
des
activ
.T-
82 In
vers
ión
CL-3
8 A
ir D
ensi
ty F
acto
r [%
]
AP-
43 V
eloc
. rei
nici
o [H
z]A
P-90
Cau
dal a
vel
ocid
ad n
omin
alT-
03 A
cció
n d
esac
tiv.
T-83
Aho
rro
ene
rgét
ico
CL-7
# A
utoa
just
e PI
D
AP-
44 R
efer
. des
pert
ar/D
if. re
alim
.FB
-##
Func
. inc
endi
o/by
pass
T-04
Rep
etic
ión
T-84
Aho
rro
CL-7
0 Ti
po d
e la
zo c
erra
do
AP-
45 R
efue
rzo
de
cons
igna
FB-0
# M
odo
Ince
ndio
T-08
Tim
ed A
ctio
ns M
ode
CL-#
# La
zo c
erra
do P
IDCL
-71
Mod
o C
onfig
urac
ión
AP-
46 T
iem
po re
fuer
zo m
áx.
FB-0
0 Fu
nció
n M
odo
Ince
ndio
T-09
Tim
ed A
ctio
ns R
eact
ivat
ion
CL-0
# Re
alim
enta
ción
CL-7
2 Ca
mbi
o d
e sa
lida
PID
AP-
5# F
in d
e cu
rva
FB-0
1 Co
nfig
urac
ión
de
Mod
o In
cend
ioT-
1# M
ant.
prev
.CL
-00
Fuen
te re
alim
. 1CL
-73
Niv
el m
ínim
o d
e re
alim
.
AP-
50 F
unc.
fin
de
curv
aFB
-02
Uni
dad
Mod
o In
cend
ioT-
10 E
lem
ento
de
man
teni
m.
CL-0
1 Co
nver
sión
rea
lim. 1
CL-7
4 N
ivel
máx
imo
de
real
im.
AP-
51 R
etar
do fi
n d
e cu
rva
FB-0
3 Re
fere
ncia
mín
. Mod
o In
cend
ioT-
11 A
cció
n d
e m
ante
nim
.CL
-02
Uni
dad
fuen
te re
alim
. 1CL
-79
Aut
oaju
ste
PID
AP-
6# D
etec
. cor
rea
rota
FB-0
4 Re
fere
ncia
máx
. Mod
o In
cend
ioT-
12 B
ase
tiem
po m
ante
nim
.CL
-03
Fuen
te r
ealim
. 2CL
-8#
Aju
stes
bás
icos
PID
AP-
60 F
unc.
cor
rea
rota
FB-0
5 Re
fere
ncia
inte
rna
en M
odo
Ince
ndio
T-13
Inte
rval
o t
iem
po m
ante
nim
.CL
-04
Conv
ersi
ón r
ealim
. 2CL
-81
Ctrl
nor
mal
/inve
rso
de
PID
AP-
61 P
ar c
orre
a ro
taFB
-06
Fuen
te re
fere
ncia
Mod
o In
cend
ioT-
14 F
echa
y h
ora
man
teni
m.
CL-0
5 U
nida
d fu
ente
rea
lim. 2
CL-8
2 Ve
loc.
arr
anqu
e PI
D [R
PM]
AP-
62 R
etar
do c
orre
a ro
taFB
-07
Fuen
te re
alim
. mod
o in
cend
ioT-
15 C
ódig
o r
eini
cio
man
teni
m.
CL-0
6 Fu
ente
real
im. 3
CL-8
3 Ve
loc.
arr
anqu
e PI
D [H
z]
AP-
7# C
ompr
esor
FB-0
9 M
anej
o a
larm
as M
odo
Ince
ndio
T-16
Tex
to m
ante
nim
.CL
-07
Conv
ersi
ón r
ealim
. 3CL
-84
Anc
ho b
anda
en
refe
renc
ia
AP-
70 C
ompr
esso
r St
art
Max
Spe
ed[R
PM]
FB-1
# By
pass
con
vert
idor
T-5#
Reg
istr
o e
nerg
íaCL
-08
Uni
dad
fuen
te r
ealim
. 3CL
-9#
Cont
rola
dor
PID
AP-
71 C
ompr
esso
r St
art
Max
Spe
ed[H
z]FB
-10
Func
ión
byp
ass
conv
ertid
orT-
50 R
esol
ució
n re
gist
ro e
nerg
íaCL
-12
Refe
renc
ia/U
nida
dre
alim
enta
ción
CL-9
1 Sa
tura
ción
de
PID
AP-
72 C
ompr
esso
r St
art
Max
Tim
e to
Trip
FB-1
1 Ti
empo
de
reta
rdo
byp
ass
conv
.T-
51 In
icio
per
íodo
CL-1
3 M
ínim
a re
fere
ncia
/rea
lim.
CL-9
3 G
anan
cia
prop
orc.
PID
Sobre la programación Guía rápida del AF-600 FP
DET-759A/S 29
6 6
CL-9
4 Ti
empo
inte
gral
PID
XC-3
0 Re
f./U
nida
d r
ealim
. 2 E
xt.
XC-6
2 Ti
empo
inte
gral
3 E
xt.
PC-4
3 U
mbr
al d
esco
nex.
por
eta
pas
LC-0
0 M
odo
Con
trol
ador
Lóg
ico
CL-9
5 Ti
empo
dife
renc
ial P
IDXC
-31
Refe
renc
ia m
ínim
a 2
Ext.
XC-6
3 Ti
empo
dife
renc
ial 3
Ext
.PC
-44
Velo
c. c
onex
. por
eta
pas
[RPM
]LC
-01
Even
to a
rran
que
CL-9
6 Lí
mite
gan
anci
a di
f. PI
D p
roc.
XC-3
2 Re
fere
ncia
máx
ima
2 Ex
t.XC
-64
Lím
ite g
anan
cia
dif.
PID
proc
.PC
-45
Velo
c. c
onex
. por
eta
pas
[Hz]
LC-0
2 Ev
ento
par
ada
XC-#
# Lz
cer
r. am
p. P
IDXC
-33
Fuen
te r
efer
enci
a 2
Ext.
PC-#
# Co
ntro
lado
r bo
mba
PC-4
6 Ve
loc.
des
cone
x. p
or e
tapa
s [R
PM]
LC-0
3 Re
in. L
ogic
Con
trol
l.
XC-0
# A
utoa
just
e co
ntr.
ext.
XC-3
4 Fu
ente
rea
lim. 2
Ext
.PC
-0#
Aju
stes
del
sis
tem
aPC
-47
Velo
c. d
esac
t. po
r et
apas
[Hz]
LC-1
# Co
mpa
rado
res
XC-0
0 Ti
po d
e la
zo c
erra
doXC
-35
Cons
igna
2 E
xt.
PC-0
0 Co
ntro
lado
r bo
mba
PC-5
# A
just
es a
ltern
anci
aLC
-10
Ope
rand
o c
ompa
rado
r
XC-0
1 M
odo
Con
figur
ació
nXC
-37
Refe
renc
ia 2
am
p. [U
nida
d]PC
-02
Arr
anqu
e de
l mot
orPC
-50
Alte
rn. b
omba
guí
aLC
-11
Ope
rado
r co
mpa
rado
r
XC-0
2 Ca
mbi
o d
e sa
lida
PID
XC-3
8 Re
alim
. 2 a
mp.
[Uni
dad]
PC-0
4 Ro
taci
ón b
omba
sPC
-51
Even
to a
ltern
anci
aLC
-12
Valo
r co
mpa
rado
r
XC-0
3 N
ivel
mín
imo
de
real
im.
XC-3
9 Sa
lida
2 am
p. [%
]PC
-05
Bom
ba g
uía
fija
PC-5
2 In
terv
alo
tiem
po a
ltern
anci
aLC
-2#
Tem
poriz
ador
es
XC-0
4 N
ivel
máx
imo
de
real
im.
XC-4
# PI
D C
L 2
ext.
PC-0
6 N
úmer
o d
e bo
mba
sPC
-53
Valo
r te
mpo
r. al
tern
anci
a
LC-2
0 Te
mpo
rizad
or d
el c
ontr
olad
or
lógi
co
XC-0
9 A
utoa
just
e PI
DXC
-40
Cont
rol n
orm
al/in
vers
o 2
Ext
.PC
-10
Min
imum
Run
Tim
eO
verr
ide
PC-5
4 H
ora
pred
ef. a
ltern
anci
aLC
-4#
Regl
as ló
gica
s
XC-1
# Re
f./Re
a. C
L 1
ext.
XC-4
1 G
anan
cia
prop
orci
onal
2 E
xt.
PC-1
1 M
inim
um R
un T
ime
Ove
rrid
e Va
lue
PC-5
5 A
ltern
ar s
i la
carg
a <
50%
LC-4
0 Re
gla
lógi
ca b
oole
ana
1
XC-1
0 Re
f./U
nida
d re
alim
. 1 E
xt.
XC-4
2 Ti
empo
inte
gral
2 E
xt.
PC-2
# A
just
es a
ncho
de
band
aPC
-56
Mod
o c
onex
. por
eta
pas
en a
ltern
.LC
-41
Ope
rado
r re
gla
lógi
ca 1
XC-1
1 Re
fere
ncia
mín
ima
1 Ex
t.XC
-43
Tiem
po d
ifere
ncia
l 2 E
xt.
PC-2
0 A
ncho
ban
da c
onex
ión
por
etap
asPC
-58
Reta
rdo
arr
anqu
e si
guie
nte
bom
baLC
-42
Regl
a ló
gica
boo
lean
a 2
XC-1
2 Re
fere
ncia
máx
ima
1 Ex
t.XC
-44
Lím
ite g
anan
cia
dif.
PID
pro
c.
PC-2
1 A
ncho
de
band
a de
His
tére
sis
PC-5
9 Re
tard
o fu
ncio
nam
ient
o e
n lí
nea
LC-4
3 O
pera
dor
regl
a ló
gica
2
XC-1
3 Fu
ente
ref
eren
cia
1 Ex
t.XC
-5#
Ref./
Rea.
CL
3 ex
t.PC
-22
Anc
ho b
anda
vel
oc. f
ijaPC
-8#
Esta
doLC
-44
Regl
a ló
gica
boo
lean
a 3
XC-1
4 Fu
ente
real
im. 1
Ext
.XC
-50
Ref./
Uni
dad
real
im. 3
Ext
.PC
-23
Reta
rdo
con
exió
n S
BWPC
-80
Esta
do b
omba
LC-5
# Es
tado
s
XC-1
5 Co
nsig
na 1
Ext
.XC
-51
Refe
renc
ia m
ínim
a 3
Ext.
PC-2
4 Re
tard
o d
esco
nex.
SBW
PC-8
1 Es
tado
bom
baLC
-51
Even
to d
el c
ontr
olad
or
XC-1
7 Re
fere
ncia
1 a
mp.
[Uni
dad]
XC-5
2 Re
fere
ncia
máx
ima
3 Ex
t.PC
-25
Tiem
po O
BWPC
-82
Bom
ba p
rinci
pal
LC-5
2 A
cció
n d
e co
ntro
lado
r ló
gico
XC-1
8 Re
alim
. 1 a
mp.
[Uni
dad]
XC-5
3 Fu
ente
ref
eren
cia
3 Ex
t.PC
-26
Des
cone
x. s
i no
hay
cau
dal
PC-8
3 Es
tado
rel
éB-
## F
unci
ones
de
fren
o
XC-1
9 Sa
lida
1 am
p. [%
]XC
-54
Fuen
te r
ealim
. 3 E
xt.
PC-2
7 Fu
nció
n a
ctiv
. por
eta
pas
PC-8
4 Ti
empo
act
iv. b
omba
B-0#
Fre
no C
C
XC-2
# PI
D C
L 1
ext.
XC-5
5 Co
nsig
na 3
Ext
.PC
-28
Tiem
po fu
nció
n a
ctiv
. por
etap
asPC
-85
Tiem
po a
ctiv
. rel
éB-
00 C
C m
ante
nida
XC-2
0 Co
ntro
l nor
mal
/inve
rso
1 E
xt.
XC-5
7 Re
fere
ncia
3 a
mp.
[Uni
dad]
PC-2
9 Fu
nció
n d
esac
tiv. p
or e
tapa
sPC
-86
Rein
icia
r co
ntad
ores
rel
ésB-
01 In
tens
. fre
no C
C
XC-2
1 G
anan
cia
prop
orci
onal
1 E
xt.
XC-5
8 Re
alim
. 3 a
mp.
[Uni
dad]
PC-3
0 Ti
empo
func
ión
des
activ
.po
r et
apas
PC-9
# Se
rvic
ioB-
02 T
iem
po d
e fr
enad
o C
C
XC-2
2 Ti
empo
inte
gral
1 E
xt.
XC-5
9 Sa
lida
3 Ex
t. [%
]PC
-4#
Aj.
cone
x. e
tapa
sPC
-90
Para
da b
omba
B-03
Vel
ocid
ad a
ctiv
ació
n fr
eno
CC
[RPM
]
XC-2
3 Ti
empo
dife
renc
ial 1
Ext
.XC
-6#
PID
CL
3 ex
t.
PC-4
0 Re
tard
o r
ampa
dec
el.
PC-9
1 A
ltern
. man
ual
B-04
Vel
ocid
ad d
e co
nexi
ón d
el fr
eno
CC
[Hz]
XC-2
4 Lí
mite
gan
anci
a di
f. PI
Dpr
oc.
XC-6
0 Co
ntro
l nor
mal
/inve
rso
3 E
xt.
PC-4
1 Re
tard
o r
ampa
ace
l.LC
-##C
ontr
olad
or ló
gico
B-1#
Fun
c. e
nerg
. fre
no
XC-3
# Re
f./Re
a. C
L 2
ext.
XC-6
1 G
anan
cia
prop
orci
onal
3 E
xt.
PC-4
2 U
mbr
al c
onex
. por
eta
pas
LC-0
# A
just
es L
CB-
10 F
unci
ón d
e fr
eno
B-16
Inte
nsid
ad m
áx. c
onve
rt.
B-17
Con
trol
de
sobr
eten
sión
Sobre la programación Guía rápida del AF-600 FP
30 DET-759A/S
66
6.2 Programación remota con DCT-10
GE cuenta con un programa de software para el desarrollo,el almacenamiento y la transferencia de la convertidor defrecuencia programación. El DCT-10 permite al usuarioconectar un PC al convertidor de frecuencia y realizar unaprogramación en vivo en lugar de utilizar el teclado.Además, toda la programación del convertidor defrecuencia puede realizarse sin estar conectado ydescargarse en elconvertidor de frecuencia. Tambiénpuede cargarse todo el perfil del convertidor de frecuenciaen el PC para almacenamiento de seguridad o análisis.
El conector USB o el terminal RS-485 están disponiblespara su conexión al convertidor de frecuencia.
Consulte www.geelectrical.com/drives para obtener másdetalles.
Sobre la programación Guía rápida del AF-600 FP
DET-759A/S 31
6 6
7 Advertencias y alarmas
7.1 Definiciones de advertencia y alarma
La Tabla 7.1 indica si se emite una advertencia antes de una alarma y si la alarma desconecta o bloquea por alarma launidad.
N.º Descripción Advertencia
Alarma / Desconexión
Alarma / Bloqueo poralarma
Referencia deparámetros
1 10 V bajo X
2 Err. cero activo (X) (X) AN-01 Función Cero Activo
4 Pérdida de fase de red (X) (X) (X) SP-12 Función desequil.línea
5 Tensión del enlace de CC alta X
6 Tensión del enlace de CC baja X
7 Sobretensión CC X X
8 Baja tensión CC X X
9 Sobrecarga del inversor X X
10 Exceso de temperatura del motor Sobrecargatermoelectrónica
(X) (X) F-10 Sobrecargaelectrónica
11 Exceso de temperatura del termistor delmotor
(X) (X) F-10 Sobrecargaelectrónica
12 Límite de par X X
13 Sobreintensidad X X X
14 Fallo de conexión a tierra X X X
15 Hardware incorrecto X X
16 Cortocircuito X X
17 Tiempo límite de código de control (X) (X) O-04 Función tiempo límite
cód. ctrl.
18 Arranque fallido
23 Fallo del ventilador interno X
24 Fallo del ventilador externo X SP-53 Monitor delventilador
29 Sobretemperatura del convertidor defrecuencia
X X X
30 Falta la fase U del motor (X) (X) (X) H-78 Función fallo fasemotor
31 Falta la fase V del motor (X) (X) (X) H-78 Función fallo fase
motor
32 Falta la fase W del motor (X) (X) (X) H-78 Función fallo fasemotor
33 Fallo en la carga de arranque X X
34 Fallo en la comunicación del bus de campo X X
35 Fallo de opción X X
36 Fallo de red X X
38 Fallo interno X X
39 Sensor disipador X X
40 Sobrecarga del terminal de salida digital 27 (X) E-00 Modo E/S digital,E-51 Terminal 27 modo E/S
41 Sobrecarga del terminal de salida digital 29 (X) E-00 Modo E/S digital,E-52 Terminal 29 modo E/S
Advertencias y alarmas Guía rápida del AF-600 FP
32 DET-759A/S
77
N.º Descripción Advertencia
Alarma / Desconexión
Alarma / Bloqueo poralarma
Referencia deparámetros
42 Sobrecarga de la salida digital en X30/6 (X) E-56 Sal. dig. term. X30/6(OPCGPIO)
42 Sobrecarga de la salida digital en X30/7 (X) E-57 Sal. dig. term. X30/7
(OPCGPIO)
45 45 Fallo de conexión a tierra 2
46 Fuente de alimentación de la tarjeta depotencia
X X
47 Fuente de alimentación baja de 24 V X X X
48 Fuente de alimentación baja de 1,8 V X X
49 Límite de velocidad X (X) H-36 Velocidad baja
desconexión [RPM]
50 autoajuste fallo de calibración X
51 autoajuste comprobación de Unom e Inom X
52 autoajuste Inom baja X
53 autoajuste motor demasiado grande X
54 autoajuste motor demasiado pequeño X
55 autoajuste Parámetro fuera de rango X
56 autoajuste interrumpido por el usuario X
57 autoajuste tiempo límite X
58 autoajuste fallo interno X X
59 Límite de intensidad X
60 Bloqueo externo X
62 Frecuencia de salida en límite máximo X
64 Límite de tensión X
65 Exceso de temperatura en placa de control X X X
66 Temperatura del disipador baja X
67 La configuración de opciones ha cambiado X
69 Temp. tarj.alim. X X
70 Configuración del Convertidor de frecuenciaincorrecta
X
76 Conf. ud. potenc X
79 Conf. PS no vál. X X
80 Convertidor de frecuencia inicializado a valorpredeterminado
X
91 Ajuste incorrecto de la entrada analógica 54 X
92 Sin caudal X X AP-2#
93 Bomba seca X X AP-2#
94 Fin de curva X X AP-5#
95 Correa rota X X AP-6#
96 Arr. retardado X AP-7#
97 Parada retardada X AP-7#
98 Fallo de reloj X K-7#
201 Modo incendio estaba activo
202 Límites modo incendio excedidos
203 Falta un motor
204 Rotor bloqueado
243 IGBT del freno X X
244 Temp. disipador X X X
245 Sensor disipador X X
246 Alim. tarj. pot. X X
247 Temp. tarj. pot. X X
248 Conf. PS no vál. X X
Advertencias y alarmas Guía rápida del AF-600 FP
DET-759A/S 33
7 7
N.º Descripción Advertencia
Alarma / Desconexión
Alarma / Bloqueo poralarma
Referencia deparámetros
250 Nuevas piezas rec. X
251 Nuevo cód. desc X X
Tabla 7.1 Lista de códigos de alarma / advertencia
(X) Dependiente del parámetro1) No puede realizarse el reinicio automático a través de H-04 Desc. reinic. autom.
¡NOTA!Consulte la descripción detallada y la solución de problemas en el manual de funcionamiento de AF-600 FP
Advertencias y alarmas Guía rápida del AF-600 FP
34 DET-759A/S
77
8 Especificaciones
8.1 Especificaciones técnicas generales
Alimentación de red (L1, L2, L3):Tensión de alimentación 200-240 V ±10 %, 380-480 V ±10 %, 525-600 V ±10 %, 525-690 V ±10 %
Tensión de red baja / corte de red:Durante un episodio de tensión de red baja o un corte de red, el convertidor de frecuencia continúa hasta que la tensión delcircuito intermedio desciende por debajo del nivel de parada mínimo, que generalmente es del 15 % por debajo de la tensión dealimentación nominal más baja del convertidor de frecuencia. No se puede esperar un arranque y un par completo con unatensión de red inferior al 10 % por debajo de la tensión de alimentación nominal más baja del convertidor de frecuencia.
Frecuencia de alimentación 50 / 60 Hz ±5 %Máximo desequilibrio transitorio entre fases de red 3,0 % de la tensión de alimentación nominalFactor de potencia real () ≥0,9 a la carga nominalFactor de potencia de desplazamiento (cos) cerca de la unidad (> 0,98)Conmutación en la entrada de alimentación L1, L2, L3 (arranques) ≤ 7,5 kW / 10 CV e inferior Máximo dos veces/minConmutación en la entrada de alimentación L1, L2, L3 (arranques) ≥ 7,5 kW / 10 CV e inferior Máximo una vez/minConmutación en la entrada de alimentación L1, L2, L3 (arranques) ≥ 110 kW / 150 CV y por encima Máximo una vez/2 minEntorno según la norma EN 60664-1 Categoría de sobretensión III / grado de contaminación 2
La unidad es adecuada para ser utilizada en un circuito capaz de proporcionar no más de 100 000 amperios simétricos RMS,240 / 480 / 600 V máximo.
Salida del motor (U, V, W):Tensión de salida 0-100 % de la tensión de alimentaciónFrecuencia de salida (0,25-75 kW) / (75 kW / 125 CV) 0-1000 HzFrecuencia de salida (90-1000 kW) / (90 kW / 150 CV) 0-8001) HzFrecuencia de salida en modo de flujo 0-300 HzConmutación en la salida IlimitadaTiempos de rampa 0,01-3600 s
1) Dependiente de la potencia y de la tensión
Características de par:Par de arranque (par constante) máximo 160 % durante 60 s 1)
Par de arranque máximo 180 % hasta 0,5 s 1)
Par de sobrecarga (par constante) máximo 160 % durante 60 s 1)
Par de arranque (par variable) máximo 110 % durante 60 s 1)
Par de sobrecarga (par variable) máximo 110 % durante 60 s
Tiempo de incremento de par en (independiente de fsw) 10 msTiempo de incremento de par en control del vector de flujo (para 5 kHz de fsw) 1 ms
1) El porcentaje es con relación al par nominal.2) El tiempo de respuesta de par depende de la aplicación y de la carga pero, por norma general, el paso de par de 0 a lareferencia equivale a entre 4 y 5 veces el tiempo de incremento de par.
Longitudes y secciones de cables:Longitud máx. del cable de motor, apantallado / blindado 150 mLongitud máxima del cable de motor, no apantallado / no blindado 300 mSección de cable máxima para los terminales de control, cable rígido 1,5 mm2 / 16 AWG (2 x 0,75 mm2)Sección de cable máxima para los terminales de control, cable flexible 1 mm2 /18 AWGSección de cable máxima para los terminales de control, cable con núcleo recubierto 0,5 mm2 / 20 AWGSección de cable mínima para los terminales de control 0,25 mm2
Especificaciones Guía rápida del AF-600 FP
DET-759A/S 35
8 8
Entradas digitales:Entradas digitales programables 4 (6)1)
Número de terminal 18, 19, 271), 291), 32, 33,Lógica PNP o NPNNivel de tensión 0-24 V CCNivel de tensión, «0» lógico PNP < 5 V CCNivel de tensión, «1» lógico PNP > 10 V CCNivel de tensión, «0» lógico NPN2) > 19 V CCNivel de tensión, «1» lógico NPN2) < 14 V CCTensión máxima de entrada 28 V CCRango de frecuencia de impulsos 0-110 kHz(Ciclo de trabajo) Anchura de impulsos mín. 4,5 msResistencia de entrada, Ri aprox. 4 kΩ
Parada de seguridad del terminal 372) (el terminal 37 es de lógica PNP fija):Nivel de tensión 0-24 V CCNivel de tensión, «0» lógico PNP < 4 V CCNivel de tensión, «1» lógico PNP >20 V CCTensión máxima de entrada 28 V CCIntensidad de entrada típica a 24 V 50 mA rmsIntensidad de entrada típica a 20 V 60 mA rmsCapacitancia de entrada 400 nF
Todas las entradas digitales están galvánicamente aisladas de la tensión de alimentación (PELV) y demás terminales de altatensión.1) El terminal 27 y 29 también se pueden programar como salida.
2) Consulte para más información sobre el terminal 37 y la Parada de seguridad.
Entradas analógicas:N.º de entradas analógicas 2Número de terminal 53, 54Modos Tensión o intensidadSelección de modo Interruptor S201 e interruptor S202Modo de tensión Interruptor S201 / Interruptor S202 = OFF (U)Nivel de tensión De –10 a +10 V (escalable)Resistencia de entrada, Ri aprox. 10 kΩTensión máx. ± 20 VModo de intensidad Interruptor S201 / Interruptor S202 = ON (I)Nivel de intensidad De 0 / 4 a 20 mA (escalable)Resistencia de entrada, Ri 200 Ω aproximadamenteIntensidad máx. 30 mAResolución de entradas analógicas 10 bit (signo +)Precisión de las entradas analógicas Error máx: 0,5 % de escala totalAncho de banda 100 Hz
Las entradas analógicas están galvánicamente aisladas de la tensión de alimentación (PELV) y de los demás terminales de altatensión.
Especificaciones Guía rápida del AF-600 FP
36 DET-759A/S
88
Entradas de pulsos / encoder:Entradas de pulsos / encoder programables 2/1Número de terminal de pulso / encoder 29, 331) / 322), 332)
Frecuencia máx. en los terminales 29, 32, 33 110 kHz (en contrafase)Frecuencia máx. en los terminales 29, 32, 33 5 kHz (colector abierto)Frecuencia mínima en los terminales 29, 32, 33 4 HzNivel de tensión Consulte Tensión máxima de entrada 28 V CCResistencia de entrada, Ri aprox. 4 kΩPrecisión de la entrada de pulsos (0,1-1 kHz) Error máx.: un 0,1 % de la escala completaPrecisión de la entrada de encoder (1-11 kHz) Error máx.: 0,05 % de la escala completa
Las entradas de pulsos y encoder (terminales 29, 32, 33) se encuentran galvánicamente aisladas de la tensión de alimentación(PELV) y demás terminales de alta tensión.1) Las entradas de pulsos son la 29 y la 332) Entradas de encoder: 32 = A y 33 = B
Salida analógica:Número de salidas analógicas programables 1Número de terminal 42Rango de intensidad en la salida analógica 0 / 4-20 mACarga máx. entre conexión a tierra y salida analógica 500 ΩPrecisión en salida analógica Error máx.: un 0,5 % de la escala completaResolución en la salida analógica 12 bits
La salida analógica está galvánicamente aislada de la tensión de alimentación (PELV) y de los demás terminales de alta tensión.
Tarjeta de control, comunicación serie RS-485:Número de terminal 68 (P,TX+, RX+), 69 (N,TX-, RX-)N.º de terminal 61 Común para los terminales 68 y 69
El circuito de comunicación serie RS-485 se encuentra separado funcionalmente de otros circuitos y galvánicamente aislado de latensión de alimentación (PELV).
Salida digital:Salidas digitales o de impulsos programables 2Número de terminal 27, 29 1)
Nivel de tensión en la salida digital / de frecuencia 0-24 VIntensidad de salida máx. (disipador o fuente) 40 mACarga máx. en salida de frecuencia 1 kΩCarga capacitiva máx. en salida de frecuencia 10 nFFrecuencia de salida mín. en salida de frecuencia 0 HzFrecuencia de salida máx. en salida de frecuencia 32 kHzPrecisión de salida de frecuencia Error máx.: 0,1 % de la escala totalResolución de salidas de frecuencia 12 bits
1) Los terminales 27 y 29 también pueden programarse como entradas.
La salida digital está galvánicamente aislada de la tensión de alimentación (PELV) y de los demás terminales de alta tensión.
Tarjeta de control, salida de 24 V CC:Número de terminal 12, 13Tensión de salida 24 V +1, –3 VCarga máx. 200 mA
La alimentación de 24 V CC está galvánicamente aislada de la tensión de alimentación (PELV), aunque tiene el mismo potencialque las entradas y salidas analógicas y digitales.
Salidas de relé:Salidas de relé programables 2 en forma de CN.º de terminal del relé 01 1-3 (desconexión), 1-2 (conexión)Carga máx. del terminal (CA-1)1) en 1-3 (NC), 1-2 (NA) (carga resistiva) 240 V CA, 2 ACarga máx. del terminal (CA-15)1) (Carga inductiva @ cosφ 0,4): 240 V CA, 0,2 ACarga máx. del terminal (CC-1)1) en 1-2 (NA), 1-3 (NC) (carga resistiva) 60 V CC, 1 A
Especificaciones Guía rápida del AF-600 FP
DET-759A/S 37
8 8
Carga máx. del terminal (CC-13)1) (carga inductiva) 24 V CC, 0,1 AN.º de terminal del relé 02 4-6 (desconexión), 4-5 (conexión)Carga máx. del terminal (CA-1)1) en 4-5 (NA) (Carga resistiva)2)3) Sobretensión cat. II 400 V CA, 2 ACarga máx. del terminal (CA-15)1) en 4-5 (NA) (carga inductiva a cosφ 0,4) 240 V CA, 0,2 ACarga máx. del terminal (CC-1)1) en 4-5 (NA) (carga resistiva) 80 V CC, 2 ACarga máx. del terminal (CC-13)1) en 4-5 (NA) (carga inductiva) 24 V CC, 0,1 ACarga máx. del terminal (CA-1)1) en 4-6 (NC) (carga resistiva) 240 V CA, 2 ACarga máx. del terminal (CA-15)1) en 4-6 (NC) (carga inductiva a cosφ 0,4) 240 V CA, 0,2 ACarga máx. del terminal (CC-1)1) en 4-6 (NC) (carga resistiva) 50 V CC, 2 ACarga máx. del terminal (CC-13)1) en 4-6 (NC) (carga inductiva) 24 V CC, 0,1 ACarga mín. del terminal en 1-3 (NC), 1-2 (NA), 4-6 (NC), 4-5 (NA) 24 V CC 10 mA, 24 V CA 20 mAAmbiente conforme a la norma EN 60664-1 Categoría de sobretensión III / grado de contaminación 2
1) CEI 60947 partes 4 y 5Los contactos del relé están galvánicamente aislados con respecto al resto del circuito con un aislamiento reforzado (PELV).2) Categoría de sobretensión II3) Aplicaciones UL 300 V CA 2 A
Tarjeta de control, salida de 10 V CC:Número de terminal 50Tensión de salida 10,5 V ±0,5 VCarga máx. 15 mA
La alimentación de 10 V CC está galvánicamente aislada de la tensión de alimentación (PELV) y de los demás terminales de altatensión.
Características de control:Resolución de frecuencia de salida a 0-1000 Hz ± 0,003 HzPrecisión repetida del Arranque / parada precisos (terminales 18, 19) ≤± 0,1 msTiempo de respuesta del sistema (terminales 18, 19, 27, 29, 32, 33) ≤ 2 msRango de control de velocidad (lazo abierto) 1:100 de velocidad síncronaIntervalo de control de velocidad (lazo cerrado) 1:1000 de velocidad síncronaPrecisión de velocidad (lazo abierto) 30-4000 rpm: error ±8 rpmPrecisión de la velocidad (lazo cerrado), dependiente de la resolución del dispositivo derealimentación. 0-6000 rpm: error ±0,15 rpmPrecisión de control del par (realimentación de velocidad) error máx.±5 % del par nominal
Todas las características de control se basan en un motor asíncrono de 4 polos
Entorno:Prueba de vibración de todos los tipos de protección 1,0 gHumedad relativa 5 %-95 % (CEI 721-3-3; Clase 3K3 (sin condensación) durante el funcionamientoEntorno agresivo (CEI 60068-2-43) prueba H2S Clase KdMétodo de prueba conforme a CEI 60068-2-43 H2S (10 días)Temperatura ambiente (en modo de conmutación 60 AVM)- con reducción de potencia máx. 50 °C1)
- con potencia de salida completa de motores EFF2 típicos (hasta un 90 % de la intensidad de salida) máx. 50 °C1)
- a plena intensidad de salida continua máx. 45 °C1)
1) Para obtener más información sobre la reducción de potencia, véase en la Guía de Diseño AF-600 FP la sección sobreCondiciones especiales.
Temperatura ambiente mínima durante el funcionamiento a escala completa 0 °CTemperatura ambiente mínima con rendimiento reducido – 10 °CTemperatura durante el almacenamiento / transporte –25-+65 / 70 °CAltitud máxima sobre el nivel del mar sin reducción de potencia 1000 mAltitud máxima sobre el nivel del mar con reducción de potencia 3000 m
Reducción de potencia por grandes altitudes (consulte la sección de condiciones especiales).
Normas CEM, emisión EN 61800-3, EN 61000-6-3/4, EN 55011, CEI 61800-3Normas CEM, inmunidad EN 61800-3, EN 61000-6-1/2,
Especificaciones Guía rápida del AF-600 FP
38 DET-759A/S
88
EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6Rendimiento de la tarjeta de control:Intervalo de exploración 1 msTarjeta de control, comunicación serie USB:USB estándar 1.1 (Velocidad máxima)Conector USB Conector de dispositivos USB tipo B
La conexión al PC se realiza por medio de un cable USB de dispositivo o host estándar.La conexión USB se encuentra galvánicamente aislada de la tensión de alimentación (PELV) y del resto de los terminales de altatensión.La conexión a tierra USB no se encuentra galvánicamente aislada de la protección a tierra. Utilice únicamente un ordenadorportátil aislado como conexión entre el PC y el conector USB del convertidor de frecuencia.
Protección y funciones:
• Protección térmico-electrónica del motor contra sobrecarga.
• El control de la temperatura del disipador garantiza la desconexión del convertidor de frecuencia si la temperaturaalcanza un valor predeterminado. La señal de temperatura de sobrecarga no se puede desactivar hasta que latemperatura del disipador térmico se encuentre por debajo de los valores indicados en las tablas de las siguientespáginas (valores orientativos, estas temperaturas pueden variar para diferentes potencias, tamaños de unidad,clasificaciones de protección, etc.).
• El convertidor de frecuencia está protegido frente a cortocircuitos entre los terminales U, V y W del motor.
• Si falta una fase de red, el convertidor de frecuencia se desconectará o emitirá una advertencia (en función de lacarga).
• El control de la tensión del circuito intermedio asegura que el convertidor de frecuencia se desconecte si latensión del circuito intermedio es demasiado baja o demasiado elevada.
• El convertidor de frecuencia comprueba constantemente la aparición de niveles graves de temperatura interna,corriente de carga, tensión alta en el circuito intermedio y velocidades de motor bajas. En respuesta a un nivelcrítico, el convertidor de frecuencia puede ajustar la frecuencia de conmutación y/o cambiar el patrón deconmutación a fin de asegurar el rendimiento del convertidor de frecuencia.
Especificaciones Guía rápida del AF-600 FP
DET-759A/S 39
8 8
8.2.1 Fusibles
Se recomienda utilizar fusibles y / o magnetotérmicos en el lado de la fuente de alimentación a modo de protección encaso de avería de componentes internos del convertidor de frecuencia (primer fallo).
¡NOTA!Esto es obligatorio a fin de asegurar el cumplimiento de los requisitos de la norma CEI 60364 para CE y del NEC 2009 paraUL.
ADVERTENCIAEl personal y los bienes deben estar protegidos contra las consecuencias de la avería de componentes en el interior delconvertidor de frecuencia.
Protección de circuito derivadoPara proteger la instalación frente a peligros eléctricos e incendios, todos los circuitos derivados de una instalación, aparatosde conexión, máquinas, etc., deben estar protegidos frente a cortocircuitos y sobrecorrientes de acuerdo con las normativasnacionales e internacionales.
¡NOTA!Las recomendaciones dadas no se aplican a la protección de circuito derivado para UL.
Protección ante cortocircuitos:GE recomienda utilizar los fusibles / magnetotérmicos mencionados a continuación para proteger al personal de servicio ylos bienes en caso de avería de un componente en el convertidor de frecuencia.
Protección para sobrecorriente:El convertidor de frecuencia proporciona protección de sobrecarga para limitar los peligros mortales y los daños a lapropiedad y evitar el riesgo de incendio debido al sobrecalentamiento de los cables de la instalación. El convertidor defrecuencia va equipado con una protección interna frente a sobrecorriente (F-43 Límite intensidad) que puede utilizarsecomo protección frente a sobrecargas para las líneas de alimentación (aplicaciones UL excluidas). Además, pueden utilizarsefusibles o magnetotérmicos para proteger la instalación contra sobrecorriente. La protección frente a sobrecorriente deberáatenerse a la normativa nacional.
ADVERTENCIAEn caso de mal funcionamiento, el hecho de no seguir esta recomendación podría dar lugar a riesgos personales y daños alconvertidor de frecuencia y otros equipos.
En las tablas siguientes se indica la intensidad nominal recomendada. Los fusibles recomendados son de tipo gG parapotencias bajas y medias. Para potencias superiores, se recomiendan los fusibles aR. Los magnetotérmicos se emplearánsiempre que cumplan las normas nacionales / internacionales y que limiten la energía en el interior del convertidor defrecuencia a un nivel igual o inferior al de los magnetotérmicos conformes.Si los fusibles / magnetotérmicos se seleccionan siguiendo las recomendaciones, los posibles daños en el convertidor defrecuencia se reducirán principalmente a daños en el interior de la unidad.
8.2.2 Cumplimiento de la normativa CE
Los fusibles o magnetotérmicos son obligatorios para cumplir con la norma IEC 60364. GE recomienda utilizar una selecciónde los siguientes.
Los siguientes fusibles son adecuados para su uso en un circuito capaz de proporcionar 100 000 Arms (simétricos), 240 V, o480 V, o 500 V, o 600 V, dependiendo de la clasificación de tensión del convertidor de frecuencia. Con los fusiblesadecuados, la clasificación de corriente de cortocircuito (SCCR) del convertidor de frecuencia es 100 000 Arms.
Especificaciones Guía rápida del AF-600 FP
40 DET-759A/S
88
AF-600 trifásico Tamaño de fusible recomendado Fusible máx. recomendado
kW / CV
0,75 / 1
gG-16 gG-251,5 / 2
2,2 / 3
3,7 / 5 gG-20 gG-32
5,5 / 7,5
gG-50 gG-637,5 / 10
11 / 15
15 / 20gG-80 gG-125
18,5 / 25
22 / 30 gG-125 gG-150
30 / 40 aR-160 aR-160
37 / 50 aR-200 aR-200
45 / 60 aR-250 aR-250
Tabla 8.1 200-240 V, IP20 / Chasis abierto
AF-600 trifásico Tamaño de fusible recomendado Fusible máx. recomendado
kW / CV
0,75 / 1
gG-20 gG-321,5 / 2
2,2 / 3
3,7 / 5
5,5 / 7,5
gG-63 gG-807,5 / 10
11 / 15
15 / 20 gG-80 gG-100
18,5 / 25gG-125 gG-160
22 / 30
30 / 40 aR-160 aR-160
37 / 50 aR-200 aR-200
45 / 60 aR-250 aR-250
Tabla 8.2 IP55 / Nema 12 e IP66 / Nema 4X interiores
Especificaciones Guía rápida del AF-600 FP
DET-759A/S 41
8 8
AF-600 trifásico Tamaño de fusible recomendado Fusible máx. recomendado
kW / CV
0,75 / 1
gG-16 gG-251,5 / 2
2,2 / 3
3,7 / 5
5,5 / 7,5gG-20 gG-32
7,5 / 10
11 / 15
gG-50 gG-6315 / 20
18,5 / 25
22 / 30
gG-80 gG-12530 / 40
37 / 50
45 / 60 gG-125 gG-150
55 / 75 aR-160 aR-160
75 / 100aR-250 aR-250
90 / 125
110 / 150 gG-300 gG-300
132 / 200 gG-350 gG-350
160 / 250 gG-400 gG-400
200 / 300 gG-500 gG-500
250 / 350 gG-630 gG-630
315 / 450 aR-700 aR-700
355 / 500
aR-900 aR-900400 / 550
450 / 600
500 / 650aR-1600 aR-1600
560 / 750
630 / 900aR-2000 aR-2000
710 / 1000
800 / 1200aR-2500 aR-2500
1000 / 1350
Tabla 8.3 380-480 V, IP20 / Chasis abierto
Especificaciones Guía rápida del AF-600 FP
42 DET-759A/S
88
AF-600 trifásico Tamaño de fusible recomendado Fusible máx. recomendado
kW / CV
0,75 / 1 gG-20 gG-32
1,5 / 2
2,2 / 3
3,7 / 5
5,5 / 7,5
7,5 / 10
11 / 15 gG-50 gG-80
15 / 20
18,5 / 25
22 / 30 gG-80 gG-100
30 / 40
37 / 50 gG-125 gG-160
45 / 60
55 / 75
75 / 100 aR-250 aR-250
90 / 125
110 / 150 gG-300 gG-300
132 / 200 gG-350 gG-350
160 / 250 gG-400 gG-400
200 / 300 gG-500 gG-500
250 / 350 gG-630 gG-630
315 / 450 aR-700 aR-700
355 / 500
aR-900 aR-900400 / 550
450 / 600
500 / 650aR-1600 aR-1600
560 / 750
630 / 900aR-2000 aR-2000
710 / 1000
800 / 1200aR-2500 aR-2500
1000 / 1350
Tabla 8.4 380-480 V, IP55 / Nema 12
Especificaciones Guía rápida del AF-600 FP
DET-759A/S 43
8 8
AF-600 trifásico Tamaño de fusible recomendado Fusible máx. recomendado
kW / CV
0,75 / 1
gG-10 gG-251,5 / 2
2,2 / 3
3,7 / 5
5,5 / 7,5gG-16 gG-32
7,5 / 10
11 / 15
gG-35 gG-6315 / 20
18,5 / 25
22 / 30
gG-63 gG-12530 / 40
37 / 50
45 / 60gG-100 gG-150
55 / 75
75 / 100aR-250 aR-250
90 / 125
Tabla 8.5 525-600 V, IP20 / Chasis abierto
AF-600 trifásico Tamaño de fusible recomendado Fusible máx. recomendado
kW / CV
0,75 / 1
gG-16 gG-32
1,5 / 2
2,2 / 3
3,7 / 5
5,5 / 7,5
7,5 / 10
11 / 15
gG-35 gG-8015 / 20
18,5 / 25
22 / 30gG-50 gG-100
30 / 40
37 / 50gG-125 gG-160
45 / 60
55 / 75
aR-250 aR-25075 / 100
90 / 125
Tabla 8.6 525-600 V, IP55 / Nema 12
Especificaciones Guía rápida del AF-600 FP
44 DET-759A/S
88
AF-600 trifásico Tamaño de fusible recomendado Fusible máx. recomendado
kW / CV
11 / 15 gG-25
gG-6315 / 20
gG-3218.5 / 25
22 / 30 gG-40
30 / 40gG-63
gG-80
37 / 50 gG-100
45 / 60 gG-80 gG-125
55 / 75 gG-100
gG-16075 / 100gG-125
90 / 125
110 / 150 aR-250 aR-250
132 / 200 aR-315 aR-315
160 / 250aR-350 aR-350
200 / 300
250 / 350 aR-400 aR-400
315 / 450 aR-500 aR-500
400 / 550 aR-550 aR-550
450 / 600aR-700 aR-700
500 / 650
560 / 750aR-900 aR-900
630 / 900
710 / 1000
aR-1600 aR-1600800 / 1150
900 / 1250
1000 / 1350
1200 / 1600 aR-2000 aR-2000
1400 / 1900 aR-2500 aR-2500
Tabla 8.7 525-690 V, IP21/Nema 1 and IP55/Nema 12
Especificaciones Guía rápida del AF-600 FP
DET-759A/S 45
8 8
8.2.3 Conformidad con UL y NEC
Los fusibles o magnetotérmicos son obligatorios para cumplir con el NEC 2009. Recomendamos utilizar una selección de lossiguientes.
Los siguientes fusibles son adecuados para su uso en un circuito capaz de proporcionar 100 000 Arms (simétricos), 240 V,480 V o 600 V, dependiendo de la clasificación de tensión del convertidor de frecuencia. Con los fusibles adecuados, laclasificación de corriente de cortocircuito (SCCR) del convertidor de frecuencia es 100 000 Arms.
Fusible máx. recomendado
AF-600potencia
monofásico
AF-600potenciatrifásico
Bussmann Bussmann Bussmann Bussmann Bussmann Bussmann
kW / CV kW / CV Tipo RK1 1) Tipo J Tipo T Tipo CC Tipo CC Tipo CC
0,75 / 1 KTN-R-10 JKS-10 JJN-10 FNQ-R-10 KTK-R-10 LP-CC-10
1,5 / 2 KTN-R-15 JKS-15 JJN-15 FNQ-R-15 KTK-R-15 LP-CC-15
1,5 / 2 2,2 / 3 KTN-R-20 JKS-20 JJN-20 FNQ-R-20 KTK-R-20 LP-CC-20
2,2 / 3 3,7 / 5 KTN-R-30 JKS-30 JJN-30 FNQ-R-30 KTK-R-30 LP-CC-30
3,7 / 5 5,5-7,5 / 7,5-10
KTN-R-50 KS-50 JJN-50 - - -
5,5 / 7,5 11 / 15 KTN-R-60 JKS-60 JJN-60 - - -
7,5 / 10 15 / 20 KTN-R-80 JKS-80 JJN-80 - - -
18,5-22 / 25-30
KTN-R-125 JKS-125 JJN-125 - - -
15 / 20 30 / 40 KTN-R-150 JKS-150 JJN-150 - - -
23 / 30 37 / 50 KTN-R-200 JKS-200 JJN-200 - - -
45 / 60 KTN-R-250 JKS-250 JJN-250 - - -
Tabla 8.8 200-240V
Fusible máx. recomendado
AF-600potenciamonofási
co
AF-600potenciatrifásico
SIBA Fusible LittelFerraz-
ShawmutFerraz-
Shawmut
kW / CV kW / CV Tipo RK1 Tipo RK1 Tipo CC Tipo RK13)
0,75 / 1 5017906-010 KLN-R-10 ATM-R-10 A2K-10-R
1,5 / 2 5017906-016 KLN-R-15 ATM-R-15 A2K-15-R
1,5 / 2 2,2 / 3 5017906-020 KLN-R-20 ATM-R-20 A2K-20-R
2,2 / 3 3,7 / 5 5012406-032 KLN-R-30 ATM-R-30 A2K-30-R
3,7 / 5 5,5-7,5 / 7,5-10
5014006-050 KLN-R-50 - A2K-50-R
5,5 / 7,5 11 / 15 5014006-063 KLN-R-60 - A2K-60-R
7,5 / 10 15 / 20 5014006-080 KLN-R-80 - A2K-80-R
18,5-22 / 25-30
2028220-125 KLN-R-125 - A2K-125-R
15 / 20 30 / 40 2028220-150 KLN-R-150 - A2K-150-R
23 / 30 37 / 50 2028220-200 KLN-R-200 - A2K-200-R
45 / 60 2028220-250 KLN-R-250 - A2K-250-R
Tabla 8.9 200-240V
Especificaciones Guía rápida del AF-600 FP
46 DET-759A/S
88
Fusible máx. recomendado
AF-600monofási
co
AF-600trifásico Bussmann Fusible Littel
Ferraz-Shawmut
Ferraz-Shawmut
kW / CV kW / CV Tipo JFHR22) Tipo JFHR2 Tipo JFHR24) Tipo J
0,75 / 1 FWX-10 - - HSJ-10
1,5 / 2 FWX-15 - - HSJ-15
1,5 / 2 2,2 / 3 FWX-20 - - HSJ-20
2,2 / 3 3,7 / 5 FWX-30 - - HSJ-30
3,7 / 5 5,5-7,5 / 7,5-10
FWX-50 - - HSJ-50
5,5 / 7,5 11 / 15 FWX-60 - - HSJ-60
7,5 / 10 15 / 20 FWX-80 - - HSJ-80
18,5-22 /
25-30
FWX-125 - - HSJ-125
15 / 20 30 / 40 FWX-150 L25S-150 A25X-150 HSJ-150
23 / 30 37 / 50 FWX-200 L25S-200 A25X-200 HSJ-200
45 / 60 FWX-250 L25S-250 A25X-250 HSJ-250
Tabla 8.10 200-240V
1) Los fusibles KTS de Bussmann pueden sustituir a los KTN en los convertidores de frecuencia de 240 V.
2) Los fusibles FWH de Bussmann pueden sustituir a los FWX en los convertidores de frecuencia de 240 V.
3) Los fusibles A6KR de FERRAZ SHAWMUT pueden sustituir a los A2KR en los convertidores de frecuencia de240 V.
4) Los fusibles A50X de FERRAZ SHAWMUT pueden sustituir a los A25X en los convertidores de frecuencia de240 V.
Fusible máx. recomendado
AF-600monofásico
AF-600trifásico
Bussmann Bussmann Bussmann Bussmann Bussmann Bussmann
kW / CV kW / CV Tipo RK1 Tipo J Tipo T Tipo CC Tipo CC Tipo CC
0,75 / 1 KTS-R-6 JKS-6 JJS-6 FNQ-R-6 KTK-R-6 LP-CC-6
1,5-2,2 / 2-3
KTS-R-10 JKS-10 JJS-10 FNQ-R-10 KTK-R-10 LP-CC-10
3,7 / 5 KTS-R-20 JKS-20 JJS-20 FNQ-R-20 KTK-R-20 LP-CC-20
5,5 / 7,5 KTS-R-25 JKS-25 JJS-25 FNQ-R-25 KTK-R-25 LP-CC-25
7,5 / 10 KTS-R-30 JKS-30 JJS-30 FNQ-R-30 KTK-R-30 LP-CC-30
11-15 /15-20
KTS-R-40 JKS-40 JJS-40 - - -
18,5 / 25 KTS-R-50 JKS-50 JJS-50 - - -
7,5 / 10 22 / 30 KTS-R-60 JKS-60 JJS-60 - - -
11 / 15 30 / 40 KTS-R-80 JKS-80 JJS-80 - - -
37 / 50 KTS-R-100 JKS-100 JJS-100 - - -
45 / 60 KTS-R-125 JKS-125 JJS-125 - - -
18,5 / 25 55 / 75 KTS-R-150 JKS-150 JJS-150 - - -
37 / 50 75 / 100 KTS-R-200 JKS-200 JJS-200 - - -
90 / 125 KTS-R-250 JKS-250 JJS-250 - - -
Tabla 8.11 380-480 V, 125 CV e inferior
Especificaciones Guía rápida del AF-600 FP
DET-759A/S 47
8 8
Fusible máx. recomendado
AF-600monofásico
AF-600 trifásico SIBA Fusible LittelFerraz-
ShawmutFerraz-
Shawmut
kW / CV kW / CV Tipo RK1 Tipo RK1 Tipo CC Tipo RK1
0,75 / 1 5017906-006 KLS-R-6 ATM-R-6 A6K-10-6
1,5-2,2 / 2-3 5017906-010 KLS-R-10 ATM-R-10 A6K-10-R
3,7 / 5 5017906-020 KLS-R-20 ATM-R-20 A6K-20-R
5,5 / 7,5 5017906-025 KLS-R-25 ATM-R-25 A6K-25-R
7,5 / 10 5012406-032 KLS-R-30 ATM-R-30 A6K-30-R
11-15 / 15-20 5014006-040 KLS-R-40 - A6K-40-R
18,5 / 25 5014006-050 KLS-R-50 - A6K-50-R
7,5 / 10 22 / 30 5014006-063 KLS-R-60 - A6K-60-R
11 / 15 30 / 40 2028220-100 KLS-R-80 - A6K-80-R
37 / 50 2028220-125 KLS-R-100 - A6K-100-R
45 / 60 2028220-125 KLS-R-125 - A6K-125-R
18,5 / 25 55 / 75 2028220-160 KLS-R-150 - A6K-150-R
37 / 50 75 / 100 2028220-200 KLS-R-200 - A6K-200-R
90 / 125 2028220-250 KLS-R-250 - A6K-250-R
Tabla 8.12 380-480 V, 125 CV e inferior
Fusible máx. recomendado
AF-600monofásico
AF-600 trifásico Bussmann Ferraz- Shawmut Ferraz- Shawmut Fusible Littel
kW / CV kW / CV Tipo JFHR2 Tipo J Tipo JFHR21) Tipo JFHR2
0,75 / 1 FWH-6 HSJ-6 - -
1,5-2,2 / 2-3 FWH-10 HSJ-10 - -
3,7 / 5 FWH-20 HSJ-20 - -
5,5 / 7,5 FWH-25 HSJ-25 - -
7,5 / 10 FWH-30 HSJ-30 - -
11-15 / 15-20 FWH-40 HSJ-40 - -
18,5 / 25 FWH-50 HSJ-50 - -
7,5 / 10 22 / 30 FWH-60 HSJ-60 - -
11 / 15 30 / 40 FWH-80 HSJ-80 - -
37 / 50 FWH-100 HSJ-100 - -
45 / 60 FWH-125 HSJ-125 - -
18,5 / 25 55 / 75 FWH-150 HSJ-150 - -
37 / 50 75 / 100 FWH-200 HSJ-200 A50-P-225 L50-S-225
90 / 125 FWH-250 HSJ-250 A50-P-250 L50-S-250
Tabla 8.13 380-480 V, 125 CV e inferior
1) Los fusibles A50QS de Ferraz Shawmut pueden ser sustituidos por los A50P.
Especificaciones Guía rápida del AF-600 FP
48 DET-759A/S
88
Fusible máx. recomendado
AF-600 Bussmann Bussmann Bussmann Bussmann Bussmann Bussmann
kW / CV Tipo RK1 Tipo J Tipo T Tipo CC Tipo CC Tipo CC
0,75 / 1 KTS-R-5 JKS-5 JJS-6 FNQ-R-5 KTK-R-5 LP-CC-5
1,5-2,2 / 2-3 KTS-R-10 JKS-10 JJS-10 FNQ-R-10 KTK-R-10 LP-CC-10
3,7 / 5 KTS-R20 JKS-20 JJS-20 FNQ-R-20 KTK-R-20 LP-CC-20
5,5 / 7,5 KTS-R-25 JKS-25 JJS-25 FNQ-R-25 KTK-R-25 LP-CC-25
7,5 / 10 KTS-R-30 JKS-30 JJS-30 FNQ-R-30 KTK-R-30 LP-CC-30
11-15 / 15-20 KTS-R-35 JKS-35 JJS-35 - - -
18,5 / 25 KTS-R-45 JKS-45 JJS-45 - - -
22 / 30 KTS-R-50 JKS-50 JJS-50 - - -
30 / 40 KTS-R-60 JKS-60 JJS-60 - - -
37 / 50 KTS-R-80 JKS-80 JJS-80 - - -
45 / 60 KTS-R-100 JKS-100 JJS-100 - - -
55 / 75 KTS-R-125 JKS-125 JJS-125 - - -
75 / 100 KTS-R-150 JKS-150 JJS-150 - - -
90 / 125 KTS-R-175 JKS-175 JJS-175 - - -
Tabla 8.14 525-600 V, 125 CV e inferior
Fusible máx. recomendado
AF-600 SIBA Fusible LittelFerraz-
ShawmutFerraz-
Shawmut
kW / CV Tipo RK1 Tipo RK1 Tipo RK1 Tipo J
0,75 / 1 5017906-005 KLS-R-005 A6K-5-R HSJ-6
1,5-2,2 / 2-3 5017906-010 KLS-R-010 A6K-10-R HSJ-10
3,7 / 5 5017906-020 KLS-R-020 A6K-20-R HSJ-20
5,5 / 7,5 5017906-025 KLS-R-025 A6K-25-R HSJ-25
7,5 / 10 5017906-030 KLS-R-030 A6K-30-R HSJ-30
11-15 / 15-20 5014006-040 KLS-R-035 A6K-35-R HSJ-35
18,5 / 25 5014006-050 KLS-R-045 A6K-45-R HSJ-45
22 / 30 5014006-050 KLS-R-050 A6K-50-R HSJ-50
30 / 40 5014006-063 KLS-R-060 A6K-60-R HSJ-60
37 / 50 5014006-080 KLS-R-075 A6K-80-R HSJ-80
45 / 60 5014006-100 KLS-R-100 A6K-100-R HSJ-100
55 / 75 2028220-125 KLS-R-125 A6K-125-R HSJ-125
75 / 100 2028220-150 KLS-R-150 A6K-150-R HSJ-150
90 / 125 2028220-200 KLS-R-175 A6K-175-R HSJ-175
Tabla 8.15 525-600 V, 125 CV e inferior
1) Los fusibles 170M de Bussmann mostrados utilizan el indicador visual - / 80. Los fusibles con el indicador –TN / 80 tipo T, - / 110 o TN / 110 tipo T del mismo tamaño y amperaje pueden ser sustituidos.
Especificaciones Guía rápida del AF-600 FP
DET-759A/S 49
8 8
AF-600 trifásico Bussmann Bussmann Bussmann SIBA Fusible Littel Ferraz-Shawmut Ferraz-Shawmut
kW / CV Tipo RK1 Tipo J Tipo T Tipo RK1 Tipo RK1 Tipo RK1 Tipo J
11 / 15 KTS-R-30 JKS-30 JJS-30 5017906-030 KLS-R-030 A6K-30R HST-30
15 / 20 KTS-R-35 JKS-35 JJS-35 5014006-040 KLS-R-035 A6K-35R HST-35
18,5 / 25 KTS-R-45 JKS-45 JJS-45 5014006-050 KLS-R-045 A6K-45R HST-45
22 / 30 KTS-R50 JKS-50 JJS-50 5014006-050 KLS-R-50 A6K-50R HST-50
30 / 40 KTS-R-60 JKS-60 JJS-60 5014006-063 KLS-R-060 A6K-60R HST-60
37 / 50 KTS-R-80 JKS-80 JJS-80 5014006-080 KLS-R-075 A6K-80R HST-80
45 / 60 KTS-R-100 JKS-100 JJS-100 5014006-100 KLS-R-100 A6K-100R HST-100
55 / 75 KTS-R125 JKS-125 JJS-125 2028220-125 KLS-125 A6K-125R HST-125
75 / 100 KTS-R150 JKS-150 JJS-150 2028220-150 KLS-150 A6K-150R HST-150
90 / 125 KTS-R175 JKS-175 JJS-175 2028220-200 KLS-175 A6K-175R HST-175
Tabla 8.16 525-690, IP21 / Nema 1 e IP55 / Nema 12
Especificaciones Guía rápida del AF-600 FP
50 DET-759A/S
88
Fusible máx. recomendado
AF-600 Bussmann PNAlternativa
ExternaBussmann PN
AlternativaExterna
Bussmann PN
AlternativaExternaSiba PN
Alternativa ExternaLittlefuse PN
AlternativaExternaFerraz-
-Shawmut PN
Alternativa ExternaFerraz-Shawmut PN
kW /
CVTipo JFHR2 Tipo JFHR2 Tipo T / JDDZ Tipo JFHR2 Tipo JFHR2 Tipo JFHR2
110 /150
170M3017 FWH-300 JJS-300 2028220-315 L50-S-300 A50-P-300
132 /200
170M3018 FWH-350 JJS-350 2028220-315 L50-S-350 A50-P-350
160 /250
170M4012 FWH-400 JJS-400 206xx32-400 L50-S-400 A50-P-400
200 /300
170M4014 FWH-500 JJS-500 206xx32-500 L50-S-500 A50-P-500
250 /
350
170M4016 FWH-600 JJS-600 206xx32-600 L50-S-600 A50-P-600
315 /
450
170M4017 20 610 32,700 6.9URD31D08A0700
355 /500
170M6013 22 610 32,900 6.9URD33D08A0900
400 /550
170M6013 22 610 32,900 6.9URD33D08A0900
450 /600
170M6013 22 610 32,900 6.9URD33D08A0900
500 /650
170M7081
560 /
750
170M7081
630 /900
170M7082
710 /1000
170M7082
800 /1200
170M7083
1000 /1350
170M7083
Tabla 8.17 380-480 V, por encima de 125 CV
AF-600 Bussmann PN Clasificación Alternativa Siba PN
kW / CV
500 / 650 170M8611 1100 A, 1000 V 20 781 32,1000
560 / 750 170M8611 1100 A, 1000 V 20 781 32,1000
630 / 900 170M6467 1400 A, 700 V 20 681 32,1400
710 / 1000 170M6467 1400 A, 700 V 20 681 32,1400
800 / 1200 170M8611 1100 A, 1000 V 20 781 32,1000
1000 / 1350 170M6467 1400 A, 700 V 20 681 32,1400
Tabla 8.18 Tamaño del bastidor 6, fusibles de enlace de CC de módulo inversor, 380-480 V
Especificaciones Guía rápida del AF-600 FP
DET-759A/S 51
8 8
AF-600Bussmann PN Alternativa Externa
Siba PNAlternativa ExternaFerraz-Shawmut PN
kW / CV Tipo JFHR2 Tipo JFHR2
132 / 200 170M3017 2061032,315 6.9URD30D08A0315
160 / 250 170M3018 2061032,35 6.9URD30D08A0350
200 / 300 170M4011 2061032,35 6.9URD30D08A0350
250 / 350 170M4012 2061032,4 6.9URD30D08A0400
315 / 450 170M4014 2061032,5 6.9URD30D08A0500
400 / 550 170M5011 2062032,55 6.9URD32D08A0550
450 / 600 170M4017
500 / 650 170M4017 20 610 32,700 6.9URD31D08A0700
560 / 750 170M6013 20 610 32,700 6.9URD31D08A0700
630 / 900 170M6013 22 610 32,900 6.9URD33D08A0900
710 / 1000 170M7081 22 610 32,900 6.9URD33D08A0900
800 / 1150 170M7081
900 / 1250 170M7081
1000 / 1350 170M7081
1200 / 1600 170M7082
1400 / 1900 170M7083
Tabla 8.19 525-690 V, por encima de 125 CV
AF-600 Bussmann PN Clasificación Alternativa Siba PN
kW / CV
710 / 1000 170M8611 1100 A, 1000 V 20 781 32,1000
800 / 1150 170M8611 1100 A, 1000 V 20 781 32,1000
900 / 1250 170M8611 1100 A, 1000 V 20 781 32.1000
1000 / 1350 170M8611 1100 A, 1000 V 20 781 32,1000
1200 / 1600 170M8611 1100 A, 1000 V 20 781 32,1000
1400 / 1900 170M8611 1100 A, 1000 V 20 781 32,1000
Tabla 8.20 Tamaño del bastidor 6, fusibles de enlace de CC de módulo del inversor, 525-690 V
*Los fusibles 170M de Bussmann mostrados utilizan el indicador visual - / 80, -TN / 80 tipo T, - / 110 o TN / 110 tipo T del mismo tamaño yamperaje. Pueden ser sustituidos para su uso externo.
**Para cumplir con los requisitos UL puede utilizarse cualquier fusible UL que aparezca en la lista, mínimo 500 V, con la corriente nominal corres-pondiente.
Especificaciones Guía rápida del AF-600 FP
52 DET-759A/S
88
9 Terminal y cable aplicable
9.1 Cables
Pote
ncia
[kW
/ C
V]Pr
otec
ción
Red
Mot
orCa
rga
com
part
ida
Fren
oTo
ma
detie
rra*
200-
240V
380-
480V
525-
600V
525-
690V
Par
deap
riete
[Nm
/ in
--lb
]
Dim
ensi
ones
de c
able
[mm
2(A
WG
)]
Par
deap
riete
[Nm
/ in
--lb
]
Dim
ensi
ones
de c
able
[mm
2 (A
WG
)]
Par
deap
riete
[Nm
/ in
--lb
]
Dim
ensi
ones
de c
able
[mm
2(A
WG
)]
Par
deap
riete
[Nm
/ in
--lb
]
Dim
ensi
ones
de c
able
[mm
2 (A
WG
)]
Par
deap
riete
[Nm
/ in
--lb
]0,
75-2
,2 k
W 1
-3 C
V0,
75-3
,7 k
W1-
5 CV
IP20
1,8
/ 16
4 (1
0)
1,8
/ 16
4 (1
0)1,
8 /
164
(10)
1,8
/ 16
4 (1
0)
3 /
27
3,7
kW5
CV5,
5-7,
5 kW
7,5-
10 C
V0,
75-7
,5 k
W 1
-10
CV
IP20
0,75
-3,7
kW
1-5
CV
0,75
-7,5
kW
1-10
CV
0,75
-7,5
kW
1-1
0 CV
IP
55 o
IP66
5,5-
11 k
W7,
5-15
CV
11-1
8,5
kW15
-25
CV11
-18,
5 kW
15-2
5 CV
IP
2016
(6)
16 (6
)16
(6)
16 (6
)5,
5-11
kW
7,5-
15 C
V11
-18,
5 kW
15-2
5 CV
11-1
8,5
kW15
-25
CV
IP55
oIP
661,
5 /
141,
5 /
14
15-1
8,5
kW
20-2
5 CV
22-3
7 kW
30-5
0 CV
22-3
7 kW
30-5
0 CV
IP
204,
5 /
4035
(2)
4,5
/ 40
35 (2
)4,
5 /
4035
(2)
4,5
/ 40
35 (2
)15
kW
20 C
V22
-30
kW30
-40
CV22
-30
kW30
-40
CV11
-30
kW15
-40
CVIP
55 o
IP66
3,7
/ 33
3,7
/ 33
22-3
0 kW
30-4
0 CV
45-5
5 kW
60-7
5 CV
45-5
5 kW
60-7
5 CV
IP
20
10 /
89
50 (1
)
10 /
89
50 (1
)
10 /
89
50 (1
)
10 /
89
50 (1
)
18.5
-30
kW
25-4
0 CV
37-5
5 kW
50-7
5 CV
37-5
5 kW
50-7
5 CV
IP
55 o
IP66
90 (3
/0)
90 (3
/0)
90 (3
/0)
90 (3
/0)
37-4
5 kW
50-6
0 CV
75-9
0 kW
100-
125
CV
75-9
0 kW
100-
125
CV
IP
20
14 /
124
150
(300
mcm
)14
/ 1
24
150
(300
mcm
)14
/ 1
24
95 (4
/0)
14 /
124
95 (4
/0)
37-4
5 kW
50-6
0 CV
75-9
0 kW
100-
125
CV
75-9
0 kW
100-
125
CV
37-9
0 kW
50-1
25 C
VIP
55 o
IP66
120
(4/0
)12
0 (4
/0)
120
(4/0
)12
0 (4
/0)
11
0-13
2 kW
150-
200
CV
110-
160
kW15
0-25
0 CV
todo
s
19 /
168
2 x
70 (2
x2
/ 0)
19 /
168
2 x
70 (2
x2
/ 0)
9,5
/ 84
2 x
70 (2
x2
/ 0)
9,5
/ 84
2 x
70 (2
x2
/ 0)
19 /
168
16
0-25
0 kW
250-
350
CV
200-
400
kW30
0-55
0 CV
todo
s2
x 18
5 (2
x35
0 m
cm)
2 x
185
(2 x
350
mcm
)2
x 18
5 (2
x35
0 m
cm)
2 x
185
(2 x
350
mcm
)
315-
450
kW45
0-60
0 CV
45
0-63
0 kW
600-
900
CVto
dos
4 x
240
(4 x
500
mcm
)4
x 24
0 (4
x50
0 m
cm)
19 /
168
4 x
240
(4 x
500
mcm
)
50
0-71
0 kW
650-
1000
CV
71
0-90
0 kW
1000
-125
0 CV
todo
s8
x 24
0 (8
x50
0 m
cm)
8 x
150
(8 x
300
mcm
)4
x 12
0 (4
x25
0 m
cm)
4 x
185
(4 x
350
mcm
)
80
0-10
00 k
W12
00-1
350
CV
10
00-1
400
kW13
50-1
900
CVto
dos
12 x
150
(12
x 30
0 m
cm)
6 x
185
(6 x
350
mcm
)
* D
imen
sión
máx
ima
del c
able
seg
ún e
l cód
igo
nac
iona
l
Terminal y cable aplicable Guía rápida del AF-600 FP
DET-759A/S 53
9 9
1 Sicherheit
WARNUNGHOCHSPANNUNG!Bei Anschluss an die Netzversorgung führen Frequenzum-richter Hochspannung. Installation, Inbetriebnahme undWartung dürfen ausschließlich von qualifiziertemFachpersonal vorgenommen werden. Werden Installation,Inbetriebnahme und Wartung nicht von qualifiziertemFachpersonal durchgeführt, kann dies den Tod oderschwere Verletzungen zur Folge haben.
HochspannungFrequenzumrichter sind an gefährliche Netzspannungenangeschlossen. Es müssen alle möglichen Schutzmaß-nahmen gegen elektrischen Schlag ergriffen werden. Nurgeschultes Fachpersonal, das mit elektronischen Gerätenund Betriebsmitteln vertraut ist, ist befugt, diese Geräte zuinstallieren, zu starten oder zu warten.
WARNUNGUNERWARTETER ANLAUF!Bei Anschluss des Frequenzumrichters an das Netz kannder Motor jederzeit anlaufen. Der Frequenzumrichter, derMotor und alle angetriebenen Geräte müssen betriebs-bereit sein. Sind sie beim Anschluss desFrequenzumrichters an das Wechselstromnetz nichtbetriebsbereit, kann dies zu schweren Verletzungen oderzum Tod sowie zu Sachschäden und Schäden an derAusrüstung führen.
Unerwarteter AnlaufWenn der Frequenzumrichter an das Netz angeschlossenist, kann der Motor über einen externen Schalter, einenseriellen Busbefehl, ein Sollwertsignal oder einenbehobenen Fehlerzustand gestartet werden. Ergreifen Siezum Schutz vor unerwartetem Anlauf entsprechendeVorsichtsmaßnahmen.
WARNUNGENTLADUNGSZEIT!Die Zwischenkreiskondensatoren des Frequenzumrichterskönnen auch bei abgeschalteter und getrennter Netzver-sorgung geladen bleiben. Trennen Sie zum Schutz vorelektrischen Gefahren die Netzversorgung vomFrequenzumrichter, bevor Sie Wartungs- oder Reparaturar-beiten durchführen und halten Sie die in Tabelle 1.1vorgegebene Wartezeit ein. Wird diese Wartezeit nachEntfernen der Netzversorgung vor Wartungs- oder Repara-turarbeiten am Frequenzumrichter nicht eingehalten, kanndies Tod oder schwere Verletzungen zur Folge haben.
Nennspannung
Leistungsgröße Minimale Wartezeit
200-240 V0,75-3,7 kW 4 Minuten
5,5-45 kW 15 Minuten
380-480 V
0,75-7,5 kW 4 Minuten
11-90 kW 15 Minuten
110-250 kW 20 Minuten
315-1000 kW 40 Minuten
525-600 V
0,75-7,5 kW 4 Minuten
11-90 kW 15 Minuten
110-315 kW 20 Minuten
355-1000 kW 30 Minuten
525-690 V
11-75 kW 15 Minuten
110-400 kW 20 Minuten
400-1400 kW 30 Minuten
SymboleIn diesem Handbuch werden die folgenden Symboleverwendet.
WARNUNGKennzeichnet eine potenziell gefährliche Situation, die,wenn sie nicht vermieden wird, den Tod oder schwereVerletzungen zur Folge haben könnte.
VORSICHTKennzeichnet eine potenziell gefährliche Situation, die,wenn sie nicht vermieden wird, leichte Verletzungen zurFolge haben könnte. Es kann ebenfalls als Warnung vorunsicheren Verfahren dienen.
VORSICHTKennzeichnet eine Situation, die Unfälle mit Geräte- oderSachschäden zur Folge haben könnte.
HINWEISKennzeichnet wichtige Hinweise, die beachtet werdenmüssen, um Fehler oder Betrieb von Geräten, in dem nichtdie optimale Leistung erbracht wird, zu vermeiden.
Zulassungen
Sicherheit AF-600 FP-Kurzanleitung
DET-759A/D 1
1 1
2 Einführung
Abbildung 2.1 Explosionszeichnung, Größe 1X
1 Tastatur 10 Motorausgangsklemmen 96 (U), 97 (V), 98 (W)
2 Anschluss serielle RS-485-Schnittstelle (+68, -69) 11 Relais 1 (01, 02, 03)
3 Analoger I/O-Anschluss 12 Relais 2 (04, 05, 06)
4 Tastatur-Netzstecker 13 Klemmen für Bremse (-81, +82) und Zwischenkreiskopplung (-88,
+89)
5 Analoge Schalter (A53), (A54) 14 Netzeingangsklemmen 91 (L1), 92 (L2), 93 (L3)
6 Zugentlastung für Kabel/PE 15 USB-Anschluss
7 Abschirmblech 16 Klemmenschalter serielle Schnittstelle
8 Erdungsschelle (PE) 17 Digitale I/O- und 24-V-Stromversorgung
9 Erdungsschelle und Kabelzugentlastung für abgeschirmtes
Kabel
18 Abdeckplatte der Steuerkabel
HINWEISSchlagen Sie bei anderen Gerätegrößen bitte im AF-600 FP Produkthandbuch nach.
Einführung AF-600 FP-Kurzanleitung
2 DET-759A/D
22
3 Installation
3.1 Checkliste Installationsort
• Der Frequenzumrichter benötigt Umgebungsluftzur Kühlung. Für optimalen Betrieb müssen dieBeschränkungen der Umgebungslufttemperaturbeachtet werden.
• Stellen Sie sicher, dass der Einbauort stabil genugfür die Montage des Frequenzumrichters ist.
• Das Innere des Frequenzumrichters muss frei vonStaub und Schmutz bleiben. Stellen Sie sicher,dass die Komponenten so sauber wie möglichbleiben. Im Bereich von Baustellen ist eineSchutzabdeckung erforderlich. Optional werdenggf. Gehäuse mit Schutzart IP54 benötigt.
• Bewahren Sie das Handbuch, die Zeichnungenund die Schaltbilder für genaue Installations- undBetriebsanweisungen leicht zugänglich auf. DasHandbuch muss für Bediener des Gerätsunbedingt zugänglich sein.
• Stellen Sie Geräte so nah wie möglich am Motorauf. Halten Sie die Motorkabel so kurz wiemöglich. Prüfen Sie die Motorkenndaten auftatsächliche Toleranzen. Überschreiten Sie diefolgenden Längen nicht:
• 300 m bei nicht abgeschirmtenMotorkabeln
• 150 m bei abgeschirmten Kabeln
3.2 Checkliste vor der Installation fürFrequenzumrichter und Motor
• Vergleichen Sie die Modellnummer des Geräts aufdem Typenschild mit den Bestellangaben, umsicherzustellen, dass Sie das richtige Gerät haben.
• Vergewissern Sie sich, dass Folgendes für diegleiche Nennspannung ausgelegt ist:
Netzversorgung
Frequenzumrichter
Motor
• Stellen Sie sicher, dass der Frequenzumrichter fürden richtigen Strom ausgelegt ist. Dieser mussmindestens so groß sein wie der Volllaststromdes Motors, damit der Motor volle Leistungerbringen kann
Die Motorgröße und dieFrequenzumrichter-Leistung müssen für
korrekten Überlastschutz überein-stimmen
Wenn die Nennleistung desFrequenzumrichters weniger beträgt alsdie des Motors, kann nicht die volleMotorausgangsleistung erreicht werden
3.3 Mechanische Installation
3.3.1 Kühlung
• Sorgen Sie durch Montage des Geräts auf einerflachen, stabilen Oberfläche oder an deroptionalen Rückwand für eine ausreichendeLuftzirkulation zur Kühlung.
• Es muss ausreichend Freiraum über und unterdem Frequenzumrichter zur Luftzirkulationvorgesehen werden. In der Regel werden 100-225mm benötigt.
• Eine unsachgemäße Montage kann Überhitzungund eine reduzierte Leistung zur Folge haben.
• Eine Leistungsreduzierung aufgrund hoherTemperaturen zwischen 40 °C und 50 °C undeiner Höhenlage von 1000 m über dem Meeres-spiegel muss berücksichtigt werden. WeitereInformationen finden Sie im Projektierungs-handbuch.
Abbildung 3.1 Abstand zur Kühlung oben und unten
Installation AF-600 FP-Kurzanleitung
DET-759A/D 3
3 3
Nennspannung Leistungsgröße Freiraum a/b
200-240 V
0,25-3,7 kW 100 mm
5,5-30 kW 200 mm
> 30 kW 225 mm
380-480 V
0,37-7,5 kW 100 mm
11-55 kW 200 mm
> 55 kW 225 mm
525-600 V
0,37-7,5 kW 100 mm
11-55 kW 200 mm
> 55 kW 225 mm
525-690 V alle 225 mm
Tabelle 3.1 Mindestanforderungen an den Freiraum zur Luftzirkulation
3.3.2 Heben
• Überprüfen Sie das Gewicht des Frequenzum-richters, um ein sicheres Hebeverfahren zubestimmen.
• Vergewissern Sie sich, dass die Hebevorrichtungfür die Aufgabe geeignet ist.
• Planen Sie ggf. zum Transportieren des Geräts einHebezeug, einen Kran oder einen Gabelstaplermit der entsprechenden Tragfähigkeit ein.
• Verwenden Sie zum Heben die Heberinge amFrequenzumrichter, sofern vorgesehen.
3.3.3 Montage
• Montieren Sie das Gerät senkrecht.
• Der Frequenzumrichter ermöglicht eine Side-by-Side-Installation
• Achten Sie darauf, dass der Montageort stabilgenug ist, um das Gewicht des Frequenzum-richters zu tragen.
• Befestigen Sie den Frequenzumrichter auf einerebenen, stabilen Oberfläche oder an deroptionalen Rückwand, um die Luftzirkulation zurKühlung zu gewährleisten (siehe Abbildung 3.2und Abbildung 3.3).
• Eine unsachgemäße Montage kann Überhitzungund reduzierte Leistung zur Folge haben.
• Verwenden Sie die Montagenute am Frequen-zumrichter zur Wandmontage, sofern vorhanden.
Abbildung 3.2 Korrekte Montage mit Rückwand
Element A ist eine Rückwand, die für die erforderlicheLuftzirkulation zum Kühlen des Geräts ordnungsgemäßmontiert ist.
Abbildung 3.3 Korrekte Montage mit Schienen
HINWEISBei Montage auf Schienen wird eine Rückwand benötigt.
Installation AF-600 FP-Kurzanleitung
4 DET-759A/D
33
3.4 Elektrische Installation
Dieser Abschnitt enthält detaillierte Anweisungen zur Verkabelung des Frequenzumrichters. Folgende Aufgaben werdenbeschrieben:
• Anschluss des Motors an die Ausgangsklemmen des Frequenzumrichters
• Anschluss des Wechselstromnetzes an die Eingangsklemmen des Frequenzumrichters
• Anschließen der Steuer- und seriellen Schnittstellenkabel
• Prüfung der Eingangs- und Motorleistungs- Programmierungs-Steuerklemmen auf ihre bestimmungsgemäßeFunktion nach Anlegen der Energiezufuhr
Abbildung 3.4 zeigt einen einfachen elektrischen Anschluss.
Abbildung 3.4 Einfacher Schaltplan
Installation AF-600 FP-Kurzanleitung
DET-759A/D 5
3 3
3.4.1 Voraussetzungen
WARNUNGGERÄTEGEFAHR!Drehende Wellen und elektrische Betriebsmittel könnenGefahren darstellen. Alle Elektroarbeiten müssen den VDE-Vorschriften und anderen geltendenElektroinstallationsvorschriften entsprechen. Installation,Inbetriebnahme und Wartung dürfen nur von qualifi-ziertem Fachpersonal vorgenommen werden. EineNichtbeachtung dieser Richtlinien kann Tod oder schwereVerletzungen zur Folge haben.
VORSICHTISOLIERUNG VON KABELNVerlegen Sie die Netzkabel, Motorkabel und Steuerkabelzum Schutz vor Hochfrequenzstörgeräuschen in dreigetrennten Kabelkanälen oder verwenden Sie getrennteabgeschirmte Kabel. Dies kann andernfalls die einwandfreieund optimale Funktion des Frequenzumrichters und derangeschlossenen Geräte beeinträchtigen.
Beachten Sie zu Ihrer eigenen Sicherheit die folgendenAnforderungen.
• Elektronische Steuer- und Regeleinrichtungensind an gefährliche Netzspannung angeschlossen.Bei Anlegen der Energiezufuhr an den Frequen-zumrichter müssen alle notwendigenSchutzmaßnahmen ergriffen werden.
• Verlegen Sie Motorkabel von mehreren Frequen-zumrichtern getrennt. Induzierte Spannung vonnebeneinander verlegten Motorkabeln kannGerätekondensatoren auch dann aufladen, wenndie Geräte freigeschaltet sind.
Überlast- und Geräteschutz
• Eine elektronisch aktivierte Funktion imFrequenzumrichter bietet Überlastschutz für denMotor. Die Überlastfunktion berechnet zurVorgabe der Zeit für die Aktivierung der Abschalt-funktion (Reglerausgangsstopp) das Maß derÜberlastzunahme. Je höher die Stromaufnahme,desto schneller das Abschaltverhalten. DieÜberlastfunktion bietet Motor-Überlastschutz derKlasse 20. Siehe 7 Warnungen und Alarmmel-dungen für nähere Informationen zurAbschaltfunktion.
• Da die Motorkabel Hochfrequenzstrom führen, isteine getrennte Verlegung der Kabel für dieNetzversorgung, Motorleistung und Steuerungwichtig. Verwenden Sie hierzu Kabelkanäle odergetrennte abgeschirmte Kabel. Ohne Trennungder Netz-, Motor- und Steuerkabel könnte die
optimale Funktion des Frequenzumrichters undder angeschlossenen Geräte beeinträchtigtwerden.
• Alle Frequenzumrichter müssen mit Kurzschluss-und Überlastschutz versehen werden. DieserSchutz wird durch Sicherungen am Einganggewährleistet, siehe Abbildung 3.5. 8.2.2 CE-Konformität und 8.2.3 Sicherungstabellen zeigt diemaximalen Nennwerte der Sicherungen.
Abbildung 3.5 Frequenzumrichter Sicherungen
Leitungstyp und Nennwerte
• Die Querschnitte und Hitzebeständigkeit der zuverwendenden Kabel sollten Sie in Überein-stimmung mit den örtlichen Normen wählen.
• GE empfiehlt, alle Leistungsanschlüsse mittelsKupferdraht mit einer Hitzebeständigkeit vonmindestens 75 °C vorzunehmen.
3.4.2 Erdungsanforderungen
WARNUNGERDUNGSGEFAHR!Aus Gründen der Bedienersicherheit ist es wichtig,Frequenzumrichter gemäß der geltenden Vorschriften undentsprechend den Anweisungen in dieser Druckschriftrichtig zu erden. Der Ableitstrom gegen Erde ist höher als3,5 mA. Eine nicht vorschriftsmäßige Erdung desFrequenzumrichters kann zum Tod oder schweren Verlet-zungen führen.
HINWEISEs obliegt dem Benutzer oder einem zertifizierten Elektro-installateur, für eine einwandfreie Erdung der Gerätegemäß geltenden nationalen und örtlichen Elektroinstallati-onsvorschriften und -normen zu sorgen.
Installation AF-600 FP-Kurzanleitung
6 DET-759A/D
33
• Beachten Sie alle örtlichen und nationalenElektroinstallationsvorschriften zur einwandfreienErdung elektrischer Geräte und Betriebsmittel.
• Bei Frequenzumrichtern mit Erdströmen vonmehr als 3,5 mA muss eine verstärkte Schutz-erdung angeschlossen werden (siehe hierzuAbleitstrom (>3,5 mA)
• Für Netz-, Motor- und Steuerkabel ist einspezieller Schutzleiter erforderlich.
• Verwenden Sie die im Lieferumfang der Frequen-zumrichter enthaltenen Kabelschellen, um dieGeräte großflächig zu erden.
• Erden Sie keinen Frequenzumrichter durchVerkettung mit einem anderen
• Halten Sie die Leitungen zur Erdung so kurz wiemöglich.
• Zur Reduzierung elektrischer Störgeräusche wirddie Verwendung von mehrdrahtigen Leitungenempfohlen.
• Befolgen Sie die Verkabelungsanforderungen desMotorherstellers.
3.4.2.1 Ableitstrom (> 3,5 mA)
Folgen Sie den nationalen und lokalen Vorschriften zurSchutzerdung der Ausrüstung mit einem Ableitstrom > 3,5mA. Die Technologie desFrequenzumrichters beinhaltet Hochfrequenzschaltungenbei hoher Leistung. Dadurch entsteht ein Ableitstrom inder Erdverbindung. Fehlerströme an den Ausgangs-klemmen des Frequenzumrichters können eineGleichstromkomponente enthalten, durch die die Filterkon-densatoren aufgeladen sowie ein Transienten-Erdstromverursacht werden kann. Der Erdableitstrom hängt vonverschiedenen Systemkonfigurationen ab, einschließlichEMV-Filterung, abgeschirmten Motorkabeln und derLeistung des Frequenzumrichters.
EN 61800-5-1 (Produktnorm für Elektrische Leistungsant-riebssysteme mit einstellbarer Drehzahl) stellt besondereAnforderungen, wenn der Erdableitstrom 3,5 mAübersteigt. Die Erdverbindung muss auf eine der folgendenArten verstärkt werden:
• Erdverbindung mit einem Leitungsquerschnittvon mindestens 10 mm2
• zwei getrennt verlegte Erdungskabel, die dievorgeschriebenen Maße einhalten
Weitere Informationen in EN 60364-5-54 § 543.7.
FehlerstromschutzschalterWenn Fehlerstromschutzschalter (RCDs), auch alsErdschlusstrennschalter bezeichnet, zum Einsatz kommen,sind die folgenden Anforderungen einzuhalten:
Verwenden Sie netzseitig nur allstromsensitiveFehlerschutzschalter (Typ B)
Verwenden Sie RCDs mit Einschaltverzögerung,um Fehler durch transiente Erdströme zuvermeiden
Bemessen Sie RCDs in Bezug auf Systemkonfigu-ration und Umgebungsbedingungen
3.4.2.2 Erdung über abgeschirmte Kabel
Erdungsschellen werden für Motorkabel mitgeliefert (sieheAbbildung 3.6).
Abbildung 3.6 Erdung mit abgeschirmtem Kabel
3.4.2.3 Erdung über Kabelkanäle
VORSICHTERDUNGSGEFAHR!Verwenden Sie keinen an den Frequenzumrichterangeschlossenen Kabelkanal als Ersatz für eine ordnungs-gemäße Erdung. Der Ableitstrom gegen Erde ist höher als3,5 mA. Falsche Erdung kann zu Personenschäden oderKurzschlüssen führen.
Es werden spezielle Erdungsschellen mitgeliefert (sieheAbbildung 3.7).
Installation AF-600 FP-Kurzanleitung
DET-759A/D 7
3 3
Abbildung 3.7 Erdung über Kabelkanäle
Abbildung 3.8 Motor-, Netz und Erdungsanschluss für Baugröße2X und höher bei Verwendung abgeschirmter Kabel
1. Isolieren Sie das Kabel 9-10 mm ab, um fürrichtige Erdung zu sorgen.
2. Befestigen Sie die Erdungsschelle mit denmitgelieferten Schrauben am abisolierten Teil desKabels.
3. Befestigen Sie das Erdungskabel an dervorgesehenen Erdungsschelle.
3.4.3 Motoranschluss
WARNUNGINDUZIERTE SPANNUNG!Verlegen Sie abgehende Motorkabel von mehrerenFrequenzumrichtern getrennt. Die induzierte Spannungvon nebeneinander verlegten Motorkabeln kann Geräte-kondensatoren auch dann aufladen, wenn die Gerätefreigeschaltet sind. Werden die Motorkabel nicht getrenntvoneinander installiert, kann dies schwere Personen-schäden oder sogar tödliche Verletzungen zur Folgehaben.
• Die Querschnitte der zu verwendenden Kabelsollten Sie in Übereinstimmung mit dengeltenden Elektroinstallationsvorschriften wählen.Siehe 9.1.1 Kabel.
• Ausstoßblenden oder Zugangsplatten fürMotorkabel sind am Unterteil von Frequenzum-richtern mit Schutzart IP55 oder höhervorgesehen.
• Installieren Sie Kondensatoren zur Korrektur desLeistungsfaktors nicht zwischen demFrequenzumrichter und dem Motor.
• Schalten Sie kein Anlass- oder Polwechselgerätzwischen den Frequenzumrichter und den Motor.
• Schließen Sie die 3 Phasen des Motorkabels andie Klemmen 96 (U), 97 (V) und 98 (W) an.
• Erden Sie das Kabel gemäß den Erdungsanwei-sungen in diesem Handbuch.
• Befolgen Sie die Verkabelungsanforderungen desMotorherstellers.
Die drei nachstehenden Abbildungen zeigen vereinfachteAnschlussbilder für Netz, Motor und Erdung eines Frequen-zumrichters. Die tatsächlichen Konfigurationen sind je nachTyp des Frequenzumrichters und der optionalen Geräteunterschiedlich.
3.4.4 Netzanschluss
• Legen Sie die Verdrahtung je nach Eingangsstromdes Frequenzumrichters aus.
• Die Querschnitte der zu verwendenden Kabelsollten Sie in Übereinstimmung mit dengeltenden Elektroinstallationsvorschriften wählen.Siehe 9.1.1 Kabel.
• Schließen Sie die 3 Phasen des Netzeingangs andie Klemmen L1, L2 und L3 an.
• Netzleistung wird an die Netz-Eingangsklemmenangeschlossen.
Installation AF-600 FP-Kurzanleitung
8 DET-759A/D
33
• Erden Sie das Kabel gemäß den Erdungsanwei-sungen in 3.4.2 Erdungsanforderungen
• Alle Frequenzumrichter können über eine isolierteNetzstromquelle oder geerdete Netzleitungenversorgt werden. Wird der Frequenzumrichter voneiner isolierten Netzstromquelle (IT-Netz oderpotentialfreie Dreieckschaltung) oder einemTT/TN-S Netz mit geerdetem Zweig (geerdeteDreieckschaltung) versorgt, so stellen Sie denEMV-Schalter über SP-50 EMV-Filter auf OFF (AUS).In der Position OFF sind die internen EMV-Filterkondensatoren zwischen Gehäusemasse undZwischenkreis abgeschaltet, um Schäden amZwischenkreis zu vermeiden und Erdkapazitäts-ströme gemäß IEC 61800-3 zu verringern.
3.4.5 Steuerkabel
• Trennen Sie Steuerkabel von Hochspannungsbau-teilen des Frequenzumrichters.
• Ist der Frequenzumrichter an einen Thermistorangeschlossen, müssen Thermistorsteuerkabel zurBeibehaltung des PELV-Schutzgrads verstärkt/zweifach isoliert sein. Eine 24-V-DC-Versorgungs-spannung wird empfohlen.
3.4.5.1 Zugriff
• Entfernen Sie die Abdeckplatte mithilfe einesSchraubendrehers. Siehe Abbildung 3.9.
• Entfernen Sie alternativ die Frontabdeckungdurch Lösen der Befestigungsschrauben. SieheAbbildung 3.10.Das Anzugsdrehmoment für die Frontabdeckungbeträgt 2,0 Nm bei der Einheitengröße 15 und 2,2Nm bei den Einheitengrößen 2X und 3X.
Abbildung 3.9 Zugriff auf die Steuerklemmen in den GehäusenIP 20
Abbildung 3.10 Zugriff auf die Steuerverdrahtung in denGehäusen IP 55 und IP 66 4/4X Indoor
3.4.5.2 Steuerklemmentypen
Abbildung 3.14 zeigt die abnehmbaren Stecker desFrequenzumrichters. Eine Zusammenfassung der Klemmen-funktionen und Werkseinstellungen finden Sie inTabelle 3.2.
Abbildung 3.11 Lage der Steuerklemmen
Installation AF-600 FP-Kurzanleitung
DET-759A/D 9
3 3
• Anschluss 1 stellt vier programmierbare Digital-eingangsklemmen, zwei zusätzliche digitaleKlemmen, die entweder als Eingang oderAusgang programmiert werden können, eine 24-VDC-Klemmen-Versorgungsspannung und einen„Common“-Ausgang für eine optionale, vomKunden bereitgestellte 24-V DC-Spannung bereit
• Anschluss 2, Klemmen (+)68 und (-)69, sind füreine serielle RS-485-Kommunikationsverbindungbestimmt
• Anschluss 3 stellt zwei Analogeingänge, einenAnalogausgang, 10-V DC-Versorgungsspannungund „Common“-Anschlüsse für die Ein- undAusgänge bereit
• Anschluss 4 ist ein USB-Anschluss zurVerwendung mit der DCT-10
• Es werden ebenfalls zwei Form-C-Relaisausgängebereitgestellt, die sich je nach Konfiguration undGröße des Frequenzumrichters an verschiedenenPositionen befinden
• Einige Optionsmodule, die zur Bestellung mitdem Gerät verfügbar sind, stellen ggf. weitereKlemmen bereit. Näheres finden Sie im Handbuchder Geräteoption.
Nähere Angaben zu Klemmenspezifikationen finden Sie in 8.1 Allgemeine technische Daten.
KlemmenbeschreibungDigitalein-/-ausgänge
Klemme Parameter
Werksein-stellung
Einstellung Beschreibung12, 13 - +24 V DC 24-V-DC-Versorgungs-
spannung MaximalerAusgangsstrom ist 200mA insgesamt für alle
24-V-Lasten.Verwendbar für Digita-leingänge und externe
Messwandler.
18 E-01 [8] Start
Digitaleingänge.
19 E-02 [0] OhneFunktion
32 E-05 [0] OhneFunktion
33 E-06 [0] OhneFunktion
27 E-03 [0] Ohne
FunktionWählbar als Digitalein-oder -ausgang.Werkseinstellung ist
Eingang.29 E-04 [14] Festdrz.
(JOG)
KlemmenbeschreibungDigitalein-/-ausgänge
Klemme Parameter
Werksein-stellung
Einstellung Beschreibung20 - „Common“ für Digita-
leingänge und 0-V-Potential für 24-V-Stromversorgung.
Analogeingänge/-ausgänge
39 -
„Common“ für Analog-ausgang
42 AN-50 Drehzahl 0 -
Max. Drehzahl
Programmierbarer
Analogausgang. DasAnalogsignal ist 0-20mA oder 4-20 mA bei
maximal 500 Ω50 - +10 V DC 10-V DC-Analogversor-
gungsspannung.Maximal 15 mA, in derRegel für Potenti-ometer oderThermistor verwendet.
53 AN-1# Sollwert Analogeingang.
Programmierbar fürSpannung oder Strom.Schalter A53 und A54
wählen mA oder V.
54 AN-2# Istwert
55 -
„Common“ für Analog-
eingang
Serielle Kommunikation
61 -
Integriertes RC-Filterfür Kabelabschirmung.NUR zum Anschlussder Abschirmung beiEMV-Problemen.
68 (+) O-3# RS-485-Schnittstelle.Ein Schalter auf derSteuerkarte dient zumZuschalten desAbschlusswiderstands.
69 (-) O-3#
Relais
01, 02, 03 E-24 [0] [0] Alarm Form-C-Relaisausgang.
Verwendbar fürWechsel- oder Gleich-spannung und
ohmsche oderinduktive Lasten.
04, 05, 06 E-24 [1] [0] Betrieb
Tabelle 3.2 Klemmenbeschreibung
Installation AF-600 FP-Kurzanleitung
10 DET-759A/D
33
3.4.5.3 Verkabelung der Steuerklemmen
Steuerklemmenanschlüsse können zur einfacheren Instal-lation vom Frequenzumrichter getrennt werden, wie inAbbildung 3.12 dargestellt.
Abbildung 3.12 Trennen der Steuerklemmen
1. Lösen Sie den Kontakt, indem Sie einen kleinenSchraubendreher in den Schlitz über oder unterdem Kontakt einführen, wie in Abbildung 3.13dargestellt.
2. Führen Sie das 9-10 mm abisolierte Steuerkabelin den Kontakt ein.
3. Entfernen Sie den Schraubendreher. Das Kabel istnun in der Klemme befestigt.
4. Stellen Sie sicher, dass der Kontakt fest hergestelltist. Lose Steuerkabel können Fehler oder einenBetrieb von Geräten zur Folge haben, in demnicht die optimale Leistung erbracht wird.
Abbildung 3.13 Anschluss der Steuerkabel
3.4.5.4 Verwendung abgeschirmterSteuerkabel
Richtige AbschirmungDie bevorzugte Methode zur Abschirmung ist in denmeisten Fällen die beidseitige Befestigung von Steuer- undseriellen Schnittstellenkabeln mit Schirmbügeln, um
möglichst großflächigen Kontakt von Hochfrequenzkabelnzu erreichen.
50/60-Hz-ErdschleifeBei sehr langen Steuerkabeln können Erdschleifenauftreten. Zur Eliminierung von Erdschleifen können Sie einEnde der Verbindung zwischen Abschirmung und Erdungan einen 100-nF-Kondensator anschließen (Leitungen kurzhalten).
Vermeidung von EMV-Störgeräuschen an Kabeln für serielleKommunikationSie können niederfrequente Störströme zwischen Frequen-zumrichtern eliminieren, indem Sie das eine Ende derAbschirmung mit Klemme 61 verbinden. Diese Klemme istintern über ein RC-Glied mit Erde verbunden. VerwendenSie verdrillte Leiter (Twisted-Pair), um die zwischen denLeitern eingestrahlten Störungen zu reduzieren.
3.4.5.5 Funktion der Steuerklemmen
Befehle für Funktionen des Frequenzumrichters werdendurch den Empfang von Eingangssignalen erteilt.
• Jede Klemme muss für ihre jeweilige Funktion inden Parametern programmiert werden, die mitdieser Klemme verknüpft sind. Tabelle 3.2 zeigtKlemmen und zugehörige Parameter.
• Es ist wichtig, zu bestätigen, dass die Steuer-klemme für die richtige Funktion programmiertist.
• Die standardmäßige Klemmenprogrammierungsoll den Betrieb des Frequenzumrichters in einertypischen Betriebsart starten.
3.4.5.6 Schalter für die Klemmen 53 und 54
• Bei den Analogeingangsklemmen 53 und 54können Sie als Eingangssignale Spannung (0 bis10 V) oder Strom (0/4-20 mA) wählen.
• Trennen Sie vor Änderung der Schaltpositionenden Frequenzumrichter von der Stromversorgung
Installation AF-600 FP-Kurzanleitung
DET-759A/D 11
3 3
• Stellen Sie die Schalter A53 und A54 zur Wahl desSignaltyps ein: U wählt Spannung, I wählt Strom.
• Sie erreichen die Schalter, wenn Sie das Tastaturabnehmen (siehe Abbildung 3.14). Die Options-module in Steckplatz B decken diese Schalter ggf.ab. Entfernen Sie diese zum Ändern der Schalter-einstellungen. (Trennen Sie vor Arbeiten amFrequenzumrichter immer die Energiezufuhr.)
• Werkseinstellung für Klemme 53 ist ein Drehzahl-sollwertsignal bei Regelung ohne Rückführung,programmiert in DR-61 AE 53 Modus.
• Werkseinstellung für Klemme 54 ist einIstwertsignal bei Regelung mit Rückführung,programmiert in DR-63 AE 54 Modus
130BT310.10
Abbildung 3.14 Lage der Schalter für die Klemmen 53 und 54
3.4.6 Serielle Kommunikation
ist eine zweiadrige Busschnittstelle, die mit einerMultidrop-Netzwerktopologie kompatibel ist, d. h. Knotenkönnen als Bus oder über Abzweigkabel über einegemeinsame Leitung verbunden werden. Insgesamtkönnen 32 Teilnehmer mit einem Netzwerksegmentverbunden werden.Netzwerksegmente sind durch Busverstärker (Repeater)unterteilt. Beachten Sie, dass jeder Repeater als Teilnehmerin dem Segment fungiert, in dem er installiert ist. Jeder miteinem Netzwerk verbundene Teilnehmer muss über alleSegmente hinweg eine einheitliche Knotenadresseaufweisen.Schließen Sie die Segmente an beiden Enden ab –entweder mithilfe des Terminierungsschalters (S801) desFrequenzumrichters oder mit einem Abschlusswiders-tandsnetz. Verwenden Sie stets ein STP-Kabel (ScreenedTwisted Pair) für die Busverkabelung, und beachten Siestets die bewährten Installationsverfahren.
Der Masseanschluss der Abschirmung mit niedrigerImpedanz ist auch bei hohen Frequenzen wichtig.Schließen Sie daher die Abschirmung großflächig an Massean, z. B. mit einer Kabelschelle oder einer leitfähigenKabelverschraubung. Ein unterschiedliches Erdpotentialzwischen Geräten kann durch Anbringen einesAusgleichskabel gelöst werden, das parallel zumSteuerkabel verlegt wird, vor allem in Anlagen mit großenKabellängen.Verwenden Sie zur Vermeidung von Impedanzabwei-chungen stets den gleichen Kabeltyp im gesamtenNetzwerk. Verwenden Sie beim Anschluss eines Motors anden Frequenzumrichter immer ein abgeschirmtesMotorkabel.
Kabel: Screened Twisted Pair (STP)
Impedanz: 120 ΩKabellänge: Max. 1200 m (einschließlich Abzweigleitungen)
Max. 500 m zwischen Stationen
Installation AF-600 FP-Kurzanleitung
12 DET-759A/D
33
4 Inbetriebnahme und Funktionsprüfung
4.1 Vor Inbetriebnahme
4.1.1 Sicherheitsinspektion
WARNUNGHOCHSPANNUNG!Wenn Ein- und Ausgangsklemmen falsch angeschlossenwerden, besteht die Gefahr, dass an diesen Hochspannunganliegt. Wenn Stromversorgungsleitungen für mehrereMotoren fälschlicherweise im selben Kabelkanal geführtwerden, können Ableitströme entstehen, durch dieKondensatoren im Frequenzumrichter aufgeladen werdenkönnen, selbst wenn sie vom Netzeingang getrennt sind.Beim ersten Start sollten keine Annahmen über dieFrequenzumrichter getroffen werden. Führen Siestattdessen die vor dem Start erforderlichen Verfahrendurch. Werden diese Verfahren nicht durchgeführt, kanndies zu Verletzungen von Personen sowie Schäden amGerät führen.
1. Die Eingangsspannung zum Frequenzumrichtermuss AUS geschalten und gesichert sein.Verlassen Sie sich nicht allein auf dieFrequenzumrichter Trennschalter zur Isolierungdes Eingangsstroms.
2. Stellen Sie sicher, dass an den EingangsklemmenL1 (91), L2 (92) und L3 (93) keine Spannungzwischen zwei Phasen sowie zwischen denPhasen und der Erde vorliegt.
3. Vergewissern Sie sich, dass keine Spannung anden Ausgangsklemmen 96 (U), 97 (V) und 98 (W)(Phase zu Phase und Phase zu Erde) anliegt.
4. Prüfen Sie den korrekten Motoranschluss durchMessen der Widerstandswerte an U-V (96-97), V-W(97-98) und W-U (98-96).
5. Überprüfen Sie die korrekte Erdverbindung desFrequenzumrichters sowie des Motors.
6. Überprüfen Sie den Frequenzumrichter auf loseVerbindungen an den Klemmen.
7. Notieren Sie die folgenden Daten vom Motor-Typenschild: Leistung, Spannung, Frequenz,Nennstrom und Nenndrehzahl. Sie benötigendiese Werte später zur Programmierung derMotor-Typenschilddaten im Frequenzumrichter.
8. Vergewissern Sie sich, dass die Versorgungs-spannung der Spannung des Frequenzumrichtersund Motors entspricht.
Inbetriebnahme und Funktion... AF-600 FP-Kurzanleitung
DET-759A/D 13
4 4
4.1.2 Checkliste vor der Inbetriebnahme
VORSICHTPrüfen Sie vor Anlegen der Netzspannung an den Frequenzumrichter die gesamte Anlage, wie in Tabelle 4.1 beschrieben.Markieren Sie die geprüften Punkte anschließend mit einem Haken.
Prüfpunkt Beschreibung Zusatzeinrichtungen • Erfassen Sie Zusatzeinrichtungen, Zubehör, Schalter, Trenner oder
Netzsicherungen bzw. Hauptschalter, die netz- oder motorseitig angeschlossensein können. Stellen Sie sicher, dass diese für einen Berieb bei voller Drehzahlbereit sind.
• Überprüfen Sie die Funktionalität und Installation aller Sensoren für dieRückführung zum Frequenzumrichter.
• Entfernen Sie die Kondensatoren zur Korrektur des Leistungsfaktors am Motor,falls vorhanden.
Kabelführung • Verlegen Sie Netzkabel, Motorkabel und Steuerkabel in drei getrenntenKabelkanälen (zum Schutz vor Hochfrequenzstörgeräuschen).
Steuerkabel • Prüfen Sie, ob Kabel gebrochen oder beschädigt sind und ob lose Verbin-dungen vorliegen.
• Stellen Sie zur Gewährleistung der Störfestigkeit sicher, dass Steuerkabelgetrennt von Netz- und Motorkabeln verlaufen.
• Prüfen Sie den Stellbereich der Signale.
• GE empfiehlt die Verwendung von abgeschirmten Kabeln oder Twisted-Pair-Kabeln. Stellen Sie sicher, dass die Abschirmung richtig abgeschlossen ist.
Luftzirkulation • Messen Sie, ob für eine ausreichende Luftzirkulation entsprechende Freiräumeüber und unter dem Frequenzumrichter vorhanden sind. Die Werte finden Sieweiter vorne in diesem Handbuch.
EMV-Aspekte • Prüfen Sie auf EMV-gerechte Installation.
Umgebungsbedingungen • Beachten Sie die Grenzwerte der maximalen Umgebungs- und Betriebstem-peratur auf dem Typenschild.
• Die relative Luftfeuchtigkeit muss zwischen 5 und 95 % ohne Kondensat-bildung liegen.
Sicherungen und Trennschalter • Stellen Sie sicher, dass die richtigen Sicherungen oder Trennschalter eingebautsind.
• Prüfen Sie, dass alle Sicherungen fest eingesetzt und in einem betriebsfähigenZustand sowie alle Trennschalter geöffnet sind.
Erdung • Stellen Sie sicher, dass ein Erdleiter zwischen dem Frequenzumrichter und derGebäudeerdung angeschlossen ist.
• Prüfen Sie, dass die Anlage eine Erdverbindung besitzt und die Kontakte festangezogen sind und keine Oxidation aufweisen.
• Eine Erdung an Kabelkanälen oder eine Montage der Rückwand an einerMetallfläche stellen keine ausreichende Erdung dar.
Netz- und Motorkabel • Prüfen Sie, dass alle Kontakte fest angeschlossen sind.
• Stellen Sie sicher, dass Motor- und Netzkabel in getrennten Kabelkanälenverlegt sind oder verwenden Sie getrennte abgeschirmte Kabel.
Gehäuseinneres • Stellen Sie sicher, dass das Innere des Frequenzumrichters frei von Schmutz,Metallspänen, Feuchtigkeit und Korrosion ist.
Inbetriebnahme und Funktion... AF-600 FP-Kurzanleitung
14 DET-759A/D
44
Prüfpunkt Beschreibung Schalter • Stellen Sie sicher, dass alle Schalter und Trennschalter in der richtigen Schaltpo-
sition sind.
Vibrationen • Stellen Sie sicher, dass der Frequenzumrichter je nach Anforderung stabilmontiert ist oder Schwingungsdämpfer verwendet werden.
• Prüfen Sie, ob übermäßige Vibrationen vorhanden sind.
Tabelle 4.1 Checkliste vor der Inbetriebnahme
4.2 Anlegen von Spannung an den Frequenzumrichter
WARNUNGHOCHSPANNUNG!Frequenzumrichter führen bei Anschluss an dieNetzspannung Hochspannung. Installation, Inbetriebnahmeund Wartung dürfen daher nur von qualifiziertemFachpersonal durchgeführt werden. Nichtbeachtung kannzu schweren Verletzungen oder zum Tod führen.
WARNUNGUNERWARTETER ANLAUF!Bei Anschluss des Frequenzumrichters an das Netz kannder Motor jederzeit anlaufen. Der Frequenzumrichter, derMotor und alle angetriebenen Geräte müssen betriebs-bereit sein. Nichtbeachtung kann zu schwerenVerletzungen oder zum Tod sowie zu Sachschäden undSchäden an der Ausrüstung führen.
1. Stellen Sie sicher, dass die Abweichung in derSpannungssymmetrie höchstens ±3 % beträgt. Istdies nicht der Fall, so korrigieren Sie dieUnsymmetrie der Eingangsspannung, bevor Siefortfahren. Wiederholen Sie dieses Verfahren nachder Spannungskorrektur.
2. Stellen Sie sicher, dass die Verkabelung optionalerAusrüstung, sofern vorhanden, dem Zweck derAnlage entspricht.
3. Stellen Sie sicher, dass alle Bedienvorrichtungenauf AUS stehen. Die Gehäusetüren müssengeschlossen bzw. die Abdeckung muss montiertsein.
4. Schalten Sie die Stromversorgung des Geräts ein.Der Frequenzumrichter darf zu diesem ZeitpunktNICHT gestartet werden. Bei Geräten mitTrennschalter muss dieser auf EIN gestelltwerden, damit der Frequenzumrichter mit Stromversorgt wird.
4.3 Grundlegende Programmierung
Eine grundlegende Programmierung von Frequenzum-richtern vor dem eigentlichen Betrieb ist für eine optimaleLeistung erforderlich. Hierzu werden die Typenschilddatendes betriebenen Motors sowie die minimale und maximaleMotordrehzahl eingegeben. Geben Sie die Daten wienachstehend beschrieben ein. Die empfohlenen Parameter-einstellungen sind lediglich für die Inbetriebnahme undeine erste Funktionsprüfung bestimmt. Anwendungsein-stellungen können abweichen.
Geben Sie die Daten ein, während die Energiezufuhr zumFrequenzumrichter EIN, jedoch noch keine Funktion desFrequenzumrichters aktiviert ist.
1. Drücken Sie auf [Quick Menu] am Tastatur.
2. Navigieren Sie mit den Navigationstasten zurKurzinbetriebnahme und drücken Sie auf [OK].
3. Wählen Sie die Sprache und drücken Sie auf [OK].Geben Sie dann die Motordaten über dieParameter P-02, P-03, P-06, P-07, F-04 und F-05ein (nur Induktionsmotoren, überspringen Siediese Parameter bei PM-Motoren zunächst). Dieentsprechenden Angaben finden Sie auf demMotor-Typenschild. Das gesamte Quick-Menü wirdin angezeigt.
P-07 Motornennleistung [kW] oderP-02 Motornennleistung [HP]
F-05 Motornennspannung
F-04 Grundfrequenz
P-03 Motorstrom
P-06 Grunddrehzahl
4. Für F-07 Beschl.-Zeit 1 wird bei Lüftern eineEinstellung von 60 Sekunden, bei Pumpen von 10Sekunden empfohlen.
5. Für F-08 Verzög.-Zeit 1 wird bei Lüftern eineEinstellung von 60 Sekunden, bei Pumpen von 10Sekunden empfohlen.
Inbetriebnahme und Funktion... AF-600 FP-Kurzanleitung
DET-759A/D 15
4 4
6. Geben Sie unter F-10 für einen Überlastschutz derKlasse 20 die Option Elektr. ÜL Alarm 1 ein.Weitere Informationen finden Sie in 3.4.1 Voraus-setzungen
7. Geben Sie bei F-16 Min. Drehzahl [Hz] die Wertenach Anforderungen der Anwendung ein. Wenndiese Werte noch unbekannt sind, werden diefolgenden Werte empfohlen. Mit diesen kann einerster Betrieb des Frequenzumrichters gewähr-leistet werden. Ergreifen Sie jedoch allenotwendigen Vorsichtsmaßnahmen, um Geräte-schäden zu verhindern. Stellen Sie sicher, dass dieempfohlenen Werte einen sicheren Betrieb für dieFunktionsprüfung ermöglichen, bevor Sie dieGeräte starten.
Lüfter = 20 Hz
Pumpe = 20 Hz
Verdichter = 30 Hz
8. Geben Sie in F-15 Max. Frequenz [Hz] dieMotorfrequenz aus F-04 Grundfrequenz ein.
Damit ist die Kurzinbetriebnahme abgeschlossen. DrückenSie auf [Status], um zur Betriebsanzeige zurückzukehren.
Wählen Sie in P-04 Auto tune Reduziertes Auto tune oderKomplettes Auto tune aus und befolgen Sie dieAnweisungen auf dem Bildschirm. Siehe 4.4 Auto Tune
4.4 Auto Tune
Bei Auto tune handelt es sich um ein Testverfahren, mitdem elektrische Kenndaten des Motors zur Optimierungder Kompatibilität zwischen Frequenzumrichter und Motorgemessen werden.
• Der Frequenzumrichter bildet zur Regelung desAusgangsmotorstroms ein mathematischesModell des Motors. Das Verfahren testet ebenfallsdie Eingangsphasensymmetrie der Spannung. Esvergleicht die tatsächlichen Motorwerte mit denDaten, die in P-02, P-03, P-06, P-07, F-04 und F-05eingegeben werden.
• Das Verfahren erzeugt während der Messung keinMotordrehmoment und beschädigt den Motorauch nicht.
• Eine komplette Anpassung ist bei einigenMotoren ggf. nicht möglich. Wählen Sie in diesemFall Reduziertes Auto tune aus.
• Wenn ein Ausgangsfilter an den Motorangeschlossen ist, wählen Sie Reduziertes Autotune aus.
• Sollten Warnungen oder Alarme auftreten, siehe 7 Warnungen und Alarmmeldungen
4.5 Prüfen der Motordrehrichtung
Prüfen Sie vor dem Betrieb des Frequenzumrichter dieMotordrehrichtung. Der Motor läuft kurz mit 5 Hz oder derin F-16 Min. Drehzahl [Hz] eingestellten minimalenFrequenz.
1. Drücken Sie zweimal auf die Taste [Main Menu]auf dem Tastenfeld.
2. Geben Sie den Parameterdatensatz ein, blätternSie zu P-## Motordaten und drücken Sie [OK]zum Bestätigen.
3. Blättern Sie zu P-08 Motordrehrichtungsprüfung.
4. Drücken Sie [OK].
5. Navigieren Sie zu Aktiviert.
Der folgende Text wird angezeigt: Achtung! Motordreh-richtung ggf. falsch.
6. Drücken Sie [OK].
7. Befolgen Sie die Anweisungen auf demBildschirm.
Zum Ändern der Drehrichtung entfernen Sie die Energie-zufuhr zum Frequenzumrichter und warten Sie aufEntladen der Hochspannungskondensatoren. VertauschenSie die Anschlüsse von zwei der drei motor- oderFrequenzumrichter seitigen Motorkabel.
4.6 Prüfung der lokalen Steuerung
VORSICHTSTARTEN DES MOTORS!Sorgen Sie dafür, dass der Motor, das System und alleangeschlossenen Geräte startbereit sind. Es obliegt demBenutzer, einen sicheren Betrieb unter allen Bedingungensicherzustellen. Wird nicht dafür gesorgt, dass der Motor,das System und alle angeschlossenen Geräte startbereitsind, können Personen- oder Geräteschäden auftreten.
HINWEISDie Hand-Taste auf dem Tastatur sendet einen lokalenStartbefehl an den Frequenzumrichter. Die OFF-Taste dientzum Stoppen des Frequenzumrichters.Beim Betrieb im Ortbetrieb kann die Ausgangsdrehzahl desFrequenzumrichters mithilfe der Pfeiltasten am Tastaturerhöht und gesenkt werden. Die Pfeiltasten nach links undrechts bewegen den Cursor im numerischen Display.
1. Drücken Sie [Hand].
2. Beschleunigen Sie den Frequenzumrichter durchDrücken der Taste [] bis zur vollen Drehzahl.Wenn Sie den Cursor links neben den
Inbetriebnahme und Funktion... AF-600 FP-Kurzanleitung
16 DET-759A/D
44
Dezimalpunkt setzen, sind schnellere Eingangsän-derungen möglich.
3. Achten Sie darauf, ob Beschleunigungsproblemeauftreten.
4. Drücken Sie auf [OFF].
5. Achten Sie darauf, ob Verzögerungsproblemeauftreten.
Bei Beschleunigungsproblemen
• Sollten Warnungen oder Alarme auftreten, siehe 7 Warnungen und Alarmmeldungen
• Stellen Sie sicher, dass die Motordaten korrekteingegeben wurden.
• Erhöhen Sie die Beschleunigungszeit inF-07 Beschl.-Zeit 1
• Erhöhen Sie die Stromgrenze in F-43 Stromgrenze.
• Erhöhen Sie die Drehmomentgrenze inF-40 Momentgrenze (motorisch).
Bei Verzögerungsproblemen
• Sollten Warnungen oder Alarme auftreten, siehe 7 Warnungen und Alarmmeldungen
• Stellen Sie sicher, dass die Motordaten korrekteingegeben wurden.
• Erhöhen Sie die Verzög.-Zeit in F-08 Verzög.-Zeit 1
Siehe 7.1 Definitionen von Warn-/Alarmmeldungen zumZurücksetzen des Frequenzumrichters nach einerAbschaltung (Alarm).
HINWEIS4.1 Vor Inbetriebnahme bis 4.6 Prüfung der lokalen Steuerungin diesem Kapitel beschreiben die Verfahren zum Anlegender Netzspannung am Frequenzumrichter, grundlegendeProgrammierung, Konfiguration und Funktionsprüfung.
4.7 Systemstart
Vor der Durchführung des in diesem Abschnittbeschriebenen Verfahrens müssen Anwenderverkabelungund Anwendungsprogrammierung abgeschlossen sein. hilftbei dieser Aufgabe. Das folgende Verfahren wird nacherfolgter Anwendungskonfiguration durch den Benutzerempfohlen.
VORSICHTSTARTEN DES MOTORS!Sorgen Sie dafür, dass der Motor, das System und alleangeschlossenen Geräte startbereit sind. Es obliegt demBenutzer, einen sicheren Betrieb unter allen Betriebsbedin-gungen sicherzustellen. Wird nicht dafür gesorgt, dass derMotor, das System und alle angeschlossenen Gerätestartbereit sind, können Personen- oder Geräteschädenauftreten.
1. Drücken Sie [Auto].
2. Stellen Sie sicher, dass externe Steuerungsfunk-tionen korrekt an den Frequenzumrichterangeschlossen sind und die gesamte Program-mierung beendet ist.
3. Legen Sie einen externen Startbefehl an.
4. Stellen Sie den Drehzahlsollwert über denDrehzahlbereich ein.
5. Entfernen Sie den externen Startbefehl.
6. Notieren Sie eventuelle Probleme.
Sollten Warnungen oder Fehler auftreten, siehe7 Warnungen und Alarmmeldungen.
Inbetriebnahme und Funktion... AF-600 FP-Kurzanleitung
DET-759A/D 17
4 4
5 Benutzerschnittstelle
5.1 Tastenfeld
Die Bedieneinheit/Tastatur ist die Displayeinheit mitintegriertem Tastenfeld an der Vorderseite des Geräts. DieBedieneinheit/Tastatur ist die Benutzerschnittstelle desFrequenzumrichters.
Die Bedieneinheit/Tastatur verfügt über verschiedeneFunktionen für Benutzer.
• Start, Stopp und Regelung der Drehzahl beiHand-Steuerung
• Anzeige von Betriebsdaten, Zustand, Warn- undAlarmmeldungen
• Programmierung von Funktionen des Frequen-zumrichters
• Quittieren Sie den Frequenzumrichter nach einemFehler manuell, wenn automatisches Quittiereninaktiv ist.
HINWEISDer Displaykontrast kann durch Drücken der Taste[STATUS] sowie der Pfeiltaste eingestellt werden.
5.1.1 Ausführung des Tastatur
Das Tastatur verfügt über 4 separate Funktionsgruppen(siehe Abbildung 5.1).
Abbildung 5.1 Tastatur
a. Displaybereich.
b. Menütasten zur Änderung der Zustandsanzeige,zum Programmieren oder zum Zugriff auf denAlarm- und Fehlerspeicher.
c. Navigationstasten zur Programmierung vonFunktionen, Bewegen des Cursors und Drehzahl-regelung bei Hand-Steuerung. Hier befinden sichKontrollanzeigen zur Anzeige des Zustands.
Benutzerschnittstelle AF-600 FP-Kurzanleitung
18 DET-759A/D
55
d. Tasten zur Wahl der Betriebsart und zumQuittieren (Reset).
5.1.2 Einstellung von Displaywerten amTastatur
Das Display ist aktiviert, wenn der Frequenzumrichter überNetzspannung, eine DC-Zwischenkreisklemme oder eineexterne 24-V-Stromversorgung mit Spannung versorgtwird.
Die am Tastatur angezeigten Informationen können für diejeweilige Anwendung angepasst werden.
• Mit jeder Displayanzeige ist ein Parameterverknüpft.
• Optionen werden im Menü Tastenfeldsatzausgewählt.
• Display 2 hat eine alternative, größere Display-option.
• Der Zustand des Frequenzumrichters in derunteren Zeile des Displays wird automatischabgerufen und ist nicht wählbar.
Display Parameternummer Werkseinstellung
1.1 K-20 Motordrehzahl
1.2 K-21 Motornennstrom
1.3 K-22 Motornennleistung(kW)
2 K-23 Motornennfrequenz
3 K-24 Sollwert in Prozent
5.1.3 Menütasten am Display
Die Menütasten dienen zum Zugriff auf Menüs zur Parame-tereinstellung, zur Änderung der Statusanzeige imnormalen Betrieb und zur Anzeige von Einträgen imFehlerspeicher.
Taste FunktionStatus Drücken Sie diese Taste, um Betriebsinforma-
tionen anzuzeigen.
• Halten Sie die Taste im Autobetriebgedrückt, um zwischen den Zustandsan-zeigen umzuschalten.
• Drücken Sie die Taste mehrmals, um jedeZustandsanzeige zu durchblättern.
• Halten Sie [Status] gedrückt. Drücken Sie
gleichzeitig auf [] oder [], um die
Helligkeit des Displays anzupassen.
• Das Symbol oben rechts im Display zeigt dieMotordrehrichtung und den aktiven Parame-tersatz. Dies ist nicht programmierbar.
Quick Menu Bietet schnellen Zugang zu Parametern zurProgrammierung für die erste Inbetriebnahmeund vielen detaillierten Anwendungshinweisen.
• Drücken Sie die Taste, um auf Kurzinbe-triebnahme zuzugreifen, die allenotwendigen Parameter und Anweisungenzur grundlegenden Programmierung desFrequenzumrichters enthält.
• Drücken Sie die Taste, um auf Lüfter-Makros,
Pumpen-Makros, Verdichter-Makros oder MitRückführung für strukturelle Anweisungenzur Programmierung von Anwendungenzuzugreifen.
• Drücken Sie die Taste, um auf Trends zur
Echtzeit-Protokollierung auf dem Display desTastenfelds zuzugreifen.
• Drücken Sie die Taste, um auf die Parame-terdatenprüfung zuzugreifen, umÄnderungen im Parameterdatensatz festzu-stellen.
• Gehen Sie die Parameter in der gezeigtenReihenfolge durch, um die wichtigstenFunktionen einzurichten.
Benutzerschnittstelle AF-600 FP-Kurzanleitung
DET-759A/D 19
5 5
Taste FunktionMain Menu Dient zum Zugriff auf alle Programmierpa-
rameter.
• Drücken Sie die Taste zweimal, um zurnächsthöheren Menüebene zu gelangen.
• Drücken Sie die Taste einmal, um zumzuletzt aufgerufenen Menü oder Parameterzurückzukehren.
• Halten Sie die Taste gedrückt, um eineParameternummer zum direkten Zugriff aufdiesen Parameter einzugeben.
Alarm Log Zeigt eine Liste aktueller Warnungen, der
letzten 10 Alarme und den Wartungsspeicher.
• Einzelheiten zum Zustand desFrequenzumrichters vor dem Auftreten des
Alarmzustands sehen Sie, wenn Sie dieAlarmnummer mit den Navigationstastenauswählen und auf [OK] drücken.
5.1.4 Navigationstasten
Navigationstasten dienen zum Navigieren der Program-mierungsfunktionen und Bewegen des Displaycursors. DieNavigationstasten ermöglichen zudem eine Drehzahlre-gelung im Handbetrieb (Ortsteuerung). In diesem Bereichbefinden sich darüber hinaus die drei Kontrollanzeigen(LEDs) des Frequenzumrichters zur Anzeige des Zustands.
Taste FunktionBack Bringt Sie zum früheren Schritt oder zur früheren
Liste in der Menüstruktur zurück.
Cancel Macht die letzte Änderung oder den letzten Befehl
rückgängig, so lange der Anzeigemodus bzw. dieDisplayanzeige nicht geändert worden ist.
Info Zeigt Informationen zu einem Befehl, einemParameter oder einer Funktion im Anzeigefenster.
Taste FunktionNavigations-tasten
Navigieren Sie mithilfe der vier Navigationspfeilezwischen den verschiedenen Optionen in denMenüs.
OK Diese Taste wird benutzt, um auf Parameter-
gruppen zuzugreifen oder die Wahl einesParameters zu bestätigen.
LED Anzeige Funktion
Grün ON Die ON-LED ist aktiv, wenn derFrequenzumrichter an dieNetzspannung, eine DC-Zwischen-kreisklemme oder eine externe 24-V-Stromversorgung angeschlossenist.
Gelb WARN Wenn ein Warnzustand auftritt,leuchtet die gelbe WARN-LED auf.Im Display erscheint zusätzlichText, der das Problem angibt.
Rot ALARM Bei einem Fehlerzustand blinkt die
rote Alarm-LED. Im Displayerscheint zusätzlich ein Alarmtext.
5.1.5 Tasten zur lokalen Bedienung
Bedientasten befinden sich unten am Tastatur.
Taste FunktionHand Drücken Sie diese Taste, um den
Frequenzumrichter mit Hand-Steuerung zustarten.
• Mit den Navigationstasten können Sie dieDrehzahl des Frequenzumrichters regeln.
• Ein externes Stoppsignal über Steuersignaleoder serielle Kommunikation hebt den
Handbetrieb auf.
Off Stoppt den angeschlossenen Motor, schaltetjedoch nicht die Stromversorgung zumFrequenzumrichter ab.
Auto Diese Taste versetzt das System in denFernbetrieb (Autobetrieb).
• Sie reagiert auf einen externen Startbefehlüber Steuerklemmen oder serielle Kommuni-kation.
• Der Drehzahlsollwert stammt von einerexternen Quelle.
Benutzerschnittstelle AF-600 FP-Kurzanleitung
20 DET-759A/D
55
Taste FunktionReset Dient dazu, den Frequenzumrichter nach
Behebung eines Fehlers manuell zurückzusetzen.
5.2 Sichern und Kopieren vonParametereinstellungen
Programmierdaten werden intern im Frequenzumrichtergespeichert.
• Die Daten können zur Sicherung in den Speicherdes Tastatur geladen werden.
• Nach dem Sichern im Tastatur können die Datenauch wieder in den Frequenzumrichterübertragen werden.
• Zudem können die Daten auch in andereFrequenzumrichter übertragen werden, indemdas Tastatur an diese Frequenzumrichterangeschlossen und die gespeicherten Einstel-lungen übertragen werden. (So lassen sichmehrere Frequenzumrichter schnell mit dengleichen Einstellungen programmieren.)
• Die Initialisierung des Frequenzumrichters zurWiederherstellung von Werkseinstellungen ändertdie im Speicher des Tastatur gespeicherten Datennicht.
WARNUNGUNERWARTETER ANLAUF!Bei Anschluss des Frequenzumrichters an das Netz kannder Motor jederzeit anlaufen. Der Frequenzumrichter, derMotor und alle angetriebenen Geräte müssen betriebs-bereit sein. Sind sie beim Anschluss an das Netz nichtbetriebsbereit, kann dies zu schweren Verletzungen oderzum Tod sowie zu Sachschäden und Schäden an derAusrüstung führen.
5.2.1 Daten vom Frequenzumrichter imTastatur speichern
1. Drücken Sie die [OFF]-Taste, um den Motor zustoppen, bevor Sie Daten laden oder speichern.
2. Gehen Sie zu K-50 Tastenfeldkopie.
3. Drücken Sie [OK].
4. Wählen Sie Speichern in Tastatur.
5. Drücken Sie [OK]. Der Vorgang kann an einemStatusbalken verfolgt werden.
6. Drücken Sie auf [Hand] oder [Auto], um zumNormalbetrieb zurückzukehren.
5.2.2 Daten vom Tastatur zumFrequenzumrichter übertragen
1. Drücken Sie die [OFF]-Taste, um den Motor zustoppen, bevor Sie Daten laden oder speichern.
2. Gehen Sie zu K-50 Tastenfeldkopie.
3. Drücken Sie [OK].
4. Wählen Sie Lade von Tastatur, Alle.
5. Drücken Sie [OK]. Der Vorgang kann an einemStatusbalken verfolgt werden.
6. Drücken Sie auf [Hand] oder [Auto], um zumNormalbetrieb zurückzukehren.
5.3 Wiederherstellen derWerkseinstellungen
VORSICHTDie Initialisierung stellt die Werkseinstellungen desFrequenzumrichters wieder her. Alle Daten zur Program-mierung, Motordaten, Lokalisierungsinformationen undÜberwachungsdatensätze gehen verloren. Durch Speichernder Daten im Tastatur können sie vor der Initialisierunggesichert werden.
Das Zurücksetzen der Parametereinstellungen desFrequenzumrichters auf die Werkseinstellungen erfolgt perInitialisierung des Frequenzumrichters. Eine Initialisierungist über H-03 Auf Werkseinst. oder manuell möglich.
• Die Initialisierung über H-03 Auf Werkseinst. ändertkeine Daten des Frequenzumrichters wie Betriebs-stunden, über die serielle Schnittstelle gewählteOptionen, Einstellungen im Benutzer-Menü,Fehlerspeicher, Alarm Log und weitere Überwa-chungsfunktionen.
• Generell wird die Verwendung von H-03 AufWerkseinst. empfohlen.
• Eine manuelle Initialisierung löscht alle Daten zuMotor, Programmierung, Lokalisierung undÜberwachung und stellt die Werkseinstellungenwieder her.
5.3.1 Empfohlene Initialisierung
1. Drücken Sie zweimal auf [Main Menu], um aufParameter zuzugreifen.
2. Blättern Sie zu H-03 Auf Werkseinst..
3. Drücken Sie [OK].
4. Wählen Sie [2] Werkseinstellungen wiederherstellen.
5. Drücken Sie auf [OK].
Benutzerschnittstelle AF-600 FP-Kurzanleitung
DET-759A/D 21
5 5
6. Schalten Sie den Frequenzumrichterspannungslos und warten Sie, bis das Displayabschaltet.
7. Legen Sie die Spannungsversorgung an denFrequenzumrichter an.
Die Werkseinstellungen der Parameter werden währendder Inbetriebnahme wiederhergestellt. Dies kann etwaslänger als normal dauern.
8. Alarm 80 wird angezeigt.
9. Mit [Reset] kehren Sie zum normalen Betriebzurück.
5.3.2 Manuelle Initialisierung
1. Schalten Sie den Frequenzumrichterspannungslos und warten Sie, bis das Displayabschaltet.
2. Drücken Sie gleichzeitig die Tasten [Status], [MainMenu] und [OK] und legen Sie die Stromver-sorgung an den Frequenzumrichter an.
Die Werkseinstellungen der Parameter werden währendder Inbetriebnahme wiederhergestellt. Dies kann etwaslänger als normal dauern.
Manuelle Initialisierung setzt die folgendenFrequenzumrichterinformationen nicht zurück:
• ID-00 Betriebsstunden
• ID-03 Anzahl Netz-Ein
• ID-04 Anzahl Übertemperaturen
• ID-05 Anzahl Überspannungen
Benutzerschnittstelle AF-600 FP-Kurzanleitung
22 DET-759A/D
55
6.1.1 Aufbau des HauptmenüsK-
## T
asta
turk
onfig
urat
ion
K-37
Dis
play
text
1K-
8# A
nzei
ge D
atum
/Uhr
zeit
F-2#
Gru
ndle
gend
2E-
## D
igit.
Ein
-/A
usgä
nge
K-0#
Tas
tatu
r-G
rund
eins
tellu
ngen
K-38
Dis
play
text
2K-
81 A
rbei
tsta
geF-
24 H
alte
zeit
E-0#
Dig
itale
ingä
nge
K-01
Spr
ache
K-39
Dis
play
text
3K-
82 Z
usät
zl. A
rbei
tsta
geF-
26 M
tr-G
eräu
sch
(Trg
rfrq
)E-
00 S
chal
tlogi
k
K-02
Hz/
UPM
Um
scha
ltung
K-4#
Tas
tenf
eld-
Tast
enK-
83 Z
usät
zl. N
icht
arbe
itsta
geF-
27 P
WM
-Jitt
erE-
01 K
lem
me
18 D
igita
lein
gang
K-03
Län
dere
inst
ellu
ngen
K-40
[Han
d]-T
aste
auf
Tas
tenf
eld
K-89
Anz
eige
Dat
um/U
hrze
itF-
3# G
rund
lege
nd 3
E-02
Kle
mm
e 19
Dig
itale
inga
ng
K-04
Net
z-Ei
n M
odus
K-41
[Off]
-Tas
te a
uf T
aste
nfel
dF-
## G
rund
lege
nde
Para
met
erF-
37 E
rw. S
chal
tmod
usE-
03 K
lem
me
27 D
igita
lein
gang
K-05
Ort
-Bet
rieb
Ein
heit
K-42
[Aut
o]-T
aste
auf
Key
pad
F-0#
Gru
ndle
gend
0F-
38 Ü
berm
odul
atio
nE-
04 K
lem
me
29 D
igita
lein
gang
K-1#
Par
amet
ersä
tze
K-43
[Res
et]-T
aste
auf
Tas
tenf
eld
F-01
Fre
quen
zein
stel
lung
1F-
4# G
rund
lege
nd 4
E-05
Kle
mm
e 32
Dig
itale
inga
ng
K-10
Akt
iver
Sat
zK-
5# K
opie
/Spe
iche
rnF-
02 B
etrie
bsar
tF-
40 M
omen
tgre
nze
(mot
oris
ch)
E-06
Kle
mm
e 33
Dig
itale
inga
ng
K-11
Pro
gram
m S
atz
K-50
Tas
tenf
eldk
opie
F-03
Max
. Aus
gang
sfre
quen
z 1
F-41
Mom
entg
renz
e (g
ener
ator
isch
)
E-1#
Zus
ätzl
iche
Bes
chl.-
/Ver
zög.
Ram
pen
K-12
Sat
z ve
rknü
pfen
mit
K-51
Par
amet
ersa
tzko
pie
F-04
Gru
ndfr
eque
nzF-
43 S
trom
gren
zeE-
10 B
esch
l.-Ze
it 2
K-13
Anz
eige
: Ver
knüp
fte
Para
me-
ters
ätze
K-6#
Pas
swor
tsch
utz
F-05
Mot
orne
nnsp
annu
ngF-
5# E
rwei
tert
e So
llwer
teE-
11 V
erzö
g.-Z
eit
2
K-14
Anz
eige
: Par
.sät
ze/K
anal
bea
rbei
ten
K-60
Hau
ptm
enü
Pas
swor
tF-
07 B
esch
l.-Ze
it 1
F-52
Min
imal
er S
ollw
ert
E-2#
Dig
itala
usgä
nge
K-2#
Tas
tenf
eld-
Dis
play
K-61
Hau
ptm
enü
Zug
riff
ohne
PW
F-08
Ver
zög.
-Zei
t 1
F-53
Max
imal
er S
ollw
ert
E-20
Kle
mm
e 27
Dig
itala
usga
ng
K-20
Dis
play
zeile
1.1
K-65
Qui
ck-M
enü-
Pass
wor
tF-
1# G
rund
lege
nd 1
F-54
Sol
lwer
tfun
ktio
nE-
21 K
lem
me
29 D
igita
laus
gang
K-21
Dis
play
zeile
1.2
K-66
Qui
ckm
enü
Zug
riff
ohne
PW
F-10
Ele
ktro
nisc
he Ü
berla
stF-
6# S
ollw
erte
E-24
Rel
aisf
unkt
ion
K-22
Dis
play
zeile
1.3
K-7#
Uhr
eins
tellu
ngen
F-11
Fre
mdb
elüf
tung
F-64
Rel
ativ
er F
ests
ollw
ert
E-26
Ein
Ver
zög.
, Rel
ais
K-23
Dis
play
zeile
2K-
70 D
atum
und
Zei
tF-
12 T
herm
isto
rans
chlu
ssF-
9# D
igita
lpot
iE-
27 A
us V
erzö
g., R
elai
s
K-24
Dis
play
zeile
3K-
71 D
atum
sfor
mat
F-15
Max
. Fre
quen
z [H
z]F-
90 D
igita
lpot
i Ein
zels
chrit
tE-
5# E
/A-M
odus
/ Z
us. E
/A
K-25
Kur
zinb
etrie
bnah
me
K-72
Uhr
zeitf
orm
atF-
16 M
in. D
rehz
ahl [
Hz]
F-91
Bes
chl.-
/Ver
zög.
-Zei
tE-
51 K
lem
me
27 F
unkt
ion
K-3#
Tas
tenf
eld-
Benu
tzer
def.
K-74
MES
Z/So
mm
erze
itF-
17 M
ax. D
rehz
ahl [
UPM
]
F-92
Dig
italp
oti s
peic
hern
bei
Net
z-
Aus
E-52
Kle
mm
e 29
Fun
ktio
n
K-30
Ein
heit
für
benu
tzer
def.
Anz
eige
K-76
MES
Z/So
mm
erze
itsta
rtF-
18 M
in. D
rehz
ahl [
UPM
]F-
93 D
igita
lpot
i Max
. Gre
nze
E-53
Kle
mm
e X3
0/2
Dig
itale
inga
ng
K-31
Min
. Wer
t be
nutz
erde
f. A
nzei
geK-
77 M
ESZ/
Som
mer
zeite
nde
F-
94 D
igita
lpot
i Min
. Gre
nze
E-54
Kle
mm
e X3
0/3
Dig
itale
inga
ng
K-32
Max
. Wer
t be
nutz
erde
f. A
nzei
geK-
79 U
hrfe
hler
F-
95 R
ampe
nver
zöge
rung
E-55
Kle
mm
e X3
0/4
Dig
itale
inga
ng
Zur Programmierung AF-600 FP-Kurzanleitung
DET-759A/D 23
6 6
E-56
Kl.
X30/
6 D
igita
laus
gang
(OPC
GPI
O)
E-96
Kle
mm
e 29
, Wer
t be
i Bus
-Tim
eout
P-07
Mot
orne
nnle
istu
ng [k
W]
H-5
# La
stun
abh.
Ein
stel
l.A
N-1
# A
nalo
gein
gang
53
E-57
Kl.
X30/
7 D
igita
laus
gang
(OPC
GPI
O)
E-97
Kle
mm
e X3
0/6,
Wer
t be
iBu
sste
ueru
ngP-
08 M
otor
dreh
richt
ungs
prüf
ung
H-5
8 Fa
ngsc
haltu
ng T
estim
puls
e St
rom
AN
-10
Klem
me
53 S
kal.
Min
.Spa
nnun
g
E-6#
Pul
sein
gang
E-98
Kle
mm
e X3
0/6,
Wer
t be
i Bus
-Ti
meo
utP-
09 S
chlu
pfau
sgle
ich
H-5
9 Fa
ngsc
haltu
ng T
estim
puls
eFr
eque
nzA
N-1
1 Kl
emm
e 53
Ska
l. M
ax.S
pann
ung
E-60
Kle
mm
e 29
Min
. Fre
quen
zC-
## F
requ
enzr
egel
funk
tione
nP-
10 S
chlu
pfau
sgle
ich
Zei
tkon
stan
teH
-6#
Last
abh.
Ein
stel
l.A
N-1
2 Kl
emm
e 53
Ska
l. M
in.S
trom
E-61
Kle
mm
e 29
Max
. Fre
quen
zC-
0# F
requ
enzr
egel
funk
tione
nP-
3# E
rw. M
otor
date
nH
-64
Reso
nanz
däm
pfun
gA
N-1
3 Kl
emm
e 53
Ska
l. M
ax.S
trom
E-62
Kle
mm
e 29
Min
. Sol
l-/Is
twer
tC-
01 A
usbl
. Dre
hzah
l von
[Hz]
P-30
Sta
torw
ider
stan
d (R
s)H
-65
Reso
nanz
däm
pfun
g Z
eitk
onst
ante
AN
-14
Klem
me
53 S
kal.
Min
.-Sol
l-/Is
twer
t
E-63
Kle
mm
e 29
Max
. Sol
l-/Is
twer
tC-
02 A
usbl
. Dre
hzah
l von
[UPM
]P-
31 R
otor
wid
erst
and
(Rr)
H-7
# W
arnu
ngen
Gre
nzen
AN
-15
Klem
me
53 S
kal.
Max
.-Sol
l-/Is
twer
t
E-64
Pul
sein
gang
29
Filte
rzei
tC-
03 A
usbl
. Dre
hzah
l bis
[UPM
]P-
35 H
aupt
reak
tanz
(Xh)
H-7
0 W
arnu
ng S
trom
nie
drig
AN
-16
Klem
me
53 F
ilter
zeit
E-65
Kle
mm
e 33
Min
. Fre
quen
zC-
04 A
usbl
. Dre
hzah
l bis
[Hz]
P-36
Eis
enve
rlust
wid
erst
and
(Rfe
)H
-71
War
nung
Str
om h
och
AN
-17
Klem
me
53 S
igna
lfehl
er
E-66
Kle
mm
e 33
Max
. Fre
quen
zC-
05 M
ehrs
tufe
nfre
quen
z 1-
8H
-##
Hoc
hlei
stun
gspa
ram
eter
H-7
2 W
arnu
ng D
rehz
. nie
drig
AN
-2#
Ana
loge
inga
ng 5
4
E-67
Kle
mm
e 33
Min
. Sol
l-/ Is
twer
tC-
2# J
og-K
onfig
urat
ion
H-0
# H
ochl
eist
ungs
betr
ieb
H-7
3 W
arnu
ng D
rehz
. hoc
hA
N-2
0 Kl
emm
e 54
Ska
l. M
in.S
pann
ung
E-68
Kle
mm
e 33
Max
. Sol
l-/Is
twer
tC-
20 F
estd
rehz
ahl J
og [H
z]H
-03
Auf
Wer
ksei
nst.
H-7
4 W
arnu
ng S
ollw
ert
nied
r.A
N-2
1 Kl
emm
e 54
Ska
l. M
ax.S
pann
ung
E-69
Pul
sein
gang
33
Filte
rzei
tC-
21 F
estd
rehz
ahl J
og [U
PM]
H-0
4 A
utom
. Qui
tt. (
x)H
-75
War
nung
Sol
lwer
t ho
chA
N-2
2 Kl
emm
e 54
Ska
l. M
in.S
trom
E-7#
Pul
saus
gang
C-22
Bes
chl./
Verz
ög.-Z
eit
JOG
H-0
5 A
uto-
Qui
ttie
ren
(Qui
ttie
rinte
rval
l)H
-76
War
nung
Istw
ert
nied
r.A
N-2
3 Kl
emm
e 54
Ska
l. M
ax.S
trom
E-70
Kle
mm
e 27
Pul
saus
gang
C-3#
Fre
quen
zein
stel
lung
2 u
nd 3
H-0
6 Lü
fter
betr
ieb
H-7
7 W
arnu
ng Is
twer
t ho
ch
AN
-24
Klem
me
54 S
kal.
Min
.-Sol
l-/
Istw
ert
E-71
Aus
gang
27
Max
. Fre
quen
zC-
30 F
requ
enzb
efeh
l 2H
-08
Reve
rsie
rung
sspe
rre
H-7
8 M
otor
phas
en Ü
berw
achu
ngA
N-2
5 Kl
emm
e 54
Ska
l. M
ax.-S
oll-/
Istw
ert
E-72
Kle
mm
e 29
Pul
saus
gang
C-34
Fre
quen
zbef
ehl 3
H-0
9 St
artm
odus
H-8
# St
oppf
unkt
ion
AN
-26
Klem
me
54 F
ilter
zeit
E-74
Aus
gang
29
Max
. Fre
quen
zC-
4# H
alba
utom
. Übe
rspr
.-Fre
q.-
Konf
igur
atio
nH
-3#
Stop
p D
rehz
ahl
H-8
0 Fu
nktio
n b
ei S
topp
AN
-27
Klem
me
54 S
igna
lfehl
er
E-75
Kle
mm
e X3
0/6
Puls
ausg
ang
C-40
Hal
baut
om. S
prun
gfre
q.H
-36
Min
. Abs
chal
tdre
hzah
l [U
PM]
H-8
1 Ei
n.-D
rehz
ahl f
ür S
topp
funk
tion
[UPM
]A
N-3
# A
nalo
gein
gang
X30
/11
E-76
Aus
gang
X30
/6 M
ax. F
requ
enz
P-##
Mot
orda
ten
H-3
7 M
in. A
bsch
altd
rehz
ahl [
Hz]
H-8
2 Ei
n.-F
requ
enz
für
Stop
pfun
ktio
n
[Hz]
AN
-30
Kl.X
30/1
1 Sk
al. M
in. S
pann
ung
E-9#
Bus
steu
erun
gP-
0# M
otor
date
nH
-4#
Erw
eite
rte
Eins
tellu
ngen
AN
-##
Ana
loge
in-/
ausg
änge
AN
-31
Kl.X
30/1
1 Sk
al. M
ax.S
pann
ung
E-90
Dig
./Rel
ais
Aus
g. B
usst
euer
ung
P-02
Mot
orne
nnle
istu
ng [H
P]H
-40
Rege
lver
fahr
enA
N-0
# G
rund
eins
tellu
ngen
AN
-34
Klem
me
X30/
11 S
kal.
Min
.-Sol
l-/Is
twer
t
E-93
Kle
mm
e 27
, Wer
t be
iBu
sste
ueru
ngP-
03 M
otor
stro
mH
-43
Dre
hmom
entv
erha
lten
der
Las
tA
N-0
0 Si
gnal
ausf
all Z
eit
AN
-35
Kl. X
30/1
1 Sk
al.M
ax.-S
oll-/
Istw
ert
E-94
Kle
mm
e 27
, Wer
t be
i Bus
-Tim
eout
P-04
Aut
o t
une
H-4
8 Re
chts
lauf
AN
-01
Sign
alau
sfal
l Fun
ktio
nA
N-3
6 Kl
emm
e X3
0/11
Filt
erze
it
E-95
Kle
mm
e 29
, Wer
t be
i
Buss
teue
rung
P-06
Gru
nddr
ehza
hl
AN
-02
Not
fallb
etrie
b S
igna
laus
fall
Funk
tion
AN
-37
Kl. X
30/1
1 Si
gnal
fehl
er
Zur Programmierung AF-600 FP-Kurzanleitung
24 DET-759A/D
66
AN
-4#
Ana
loge
inga
ng X
30/1
2SP
-##
Sond
erfu
nktio
nen
SP-5
# U
mge
bung
O-1
3 Zu
stan
dsw
ort
Konf
igur
atio
nO
-8#
Driv
e Se
r.-D
iagn
ose
AN
-40
Klem
me
X30/
12 S
kal.
Min
.Spa
nnun
gSP
-1#
Net
zaus
fall
SP-5
0 EM
V-Fi
lter
O-3
# Se
r. FU
-Sch
nitt
stel
leO
-80
Zähl
er B
usm
eldu
ngen
AN
-41
Klem
me
X30/
12 S
kal.
Max
.Spa
nnun
gSP
-10
Net
zaus
fall
SP-5
1 Zw
isch
enkr
eisk
ompe
nsat
ion
O-3
0 Pr
otok
oll
O-8
1 Zä
hler
Bus
fehl
er
AN
-44
Klem
me
X30/
12 S
kal.
Min
.-Sol
l-/
Istw
ert
SP-1
1 N
etza
usfa
ll-Sp
annu
ngSP
-53
Lüft
erüb
erw
achu
ngO
-31
Ans
chrif
tO
-82
Zähl
er S
lave
mel
dung
en
AN
-45
Kl. X
30/1
2 Sk
al.M
ax.-S
oll-/
Istw
ert
SP-1
2 N
etzp
hase
n-U
nsym
met
rieSP
-55
Aus
gang
sfilt
erO
-32
FU-B
audr
ate
O-8
3 Zä
hler
Sla
vefe
hler
AN
-46
Klem
me
X30/
12 F
ilter
zeit
SP-2
# Re
set/
Initi
alis
iere
nSP
-59
Anz
ahl a
ktiv
er W
echs
el-
richt
erO
-33
Parit
ät/S
topp
bits
O-8
9 D
iagn
osez
ähle
r
AN
-47
Kl. X
30/1
2 Si
gnal
fehl
erSP
-23
Type
ncod
eein
stel
lung
SP-6
# A
uto-
Redu
zier
.O
-34
Ges
chät
zte
Zykl
usze
itO
-9#
Bus-
Fest
dreh
zahl
AN
-5#
Ana
loga
usga
ng 4
2SP
-25
Dre
hmom
.gre
nze
Verz
öger
ungs
zeit
SP-6
0 Fu
nktio
n b
ei Ü
bert
em-
pera
tur
O-3
5 FC
-Ant
wor
tzei
t M
in.-D
elay
O-9
0 Bu
s-Fe
stdr
ehza
hl 1
AN
-50
Klem
me
42 A
nalo
gaus
gang
SP-2
6 FU
-Feh
ler
Abs
chal
tver
zöge
rung
SP-6
1 Fu
nktio
n b
ei F
U-Ü
berla
stO
-36
FC-A
ntw
ortz
eit
Max
.-Del
ayO
-91
Bus-
Fest
dreh
zahl
2
AN
-51
Kl. 4
2, A
usga
ng m
in. S
kalie
rung
SP-2
8 Pr
oduk
tions
eins
tellu
ngen
SP-6
2 Ü
berla
st R
eduz
iers
trom
O-3
7 FC
Inte
rcha
r. M
ax.-D
elay
O-9
4 Bu
s Is
twer
t 1
AN
-52
Kl. 4
2, A
usga
ng m
ax. S
kalie
rung
SP-2
9 Se
rvic
ecod
eO
-##
Opt
./Sch
nitt
stel
len
O-4
# FU
/MC-
Prot
okol
lO
-95
Bus
Istw
ert
2
AN
-53
Kl. 4
2, W
ert
bei B
usst
euer
ung
SP-3
# St
rom
gren
zeO
-0#G
rund
eins
tellu
ngen
O-4
0 Te
legr
amm
typ
O-9
6 Bu
s Is
twer
t 3
AN
-54
Kl. 4
2, W
ert
bei B
us-T
imeo
utSP
-30
Regl
er P
-Ver
stär
kung
O-0
1 Fü
hrun
gsho
heit
O-4
2 PC
D-K
onfig
urat
ion
Sch
reib
enA
O-#
# A
nalo
g-E/
A-O
ptio
n
AN
-6#
Ana
loga
usga
ng X
30/8
SP-3
1 Re
gler
I-Ze
itO
-02
Akt
ives
Ste
uerw
ort
O-4
3 PC
D-K
onfig
urat
ion
Les
enA
O-0
# A
nalo
g-E/
A-M
odus
AN
-60
Kl. X
30/8
Ana
loga
usga
ngSP
-32
Regl
er, F
ilter
zeit
O-0
3 St
euer
wor
t Ti
meo
ut-Z
eit
O-5
# Be
tr. B
us/K
lem
me
AO
-00
Klem
me
X42/
1 Fu
nktio
n
AN
-61
Kl. X
30/8
, Aus
gang
min
.Sk
alie
rung
SP-4
# En
ergi
eein
spar
unge
nO
-04
Steu
erw
ort
Tim
eout
-Fun
ktio
nO
-50
Mot
orfr
eila
ufA
O-0
1 Kl
emm
e X4
2/3
Funk
tion
AN
-62
Kl. X
30/8
, Aus
gang
max
.Sk
alie
rung
SP-4
0 Q
uadr
.Mom
. Anp
assu
ngO
-05
Steu
erw
ort
Tim
eout
-End
eO
-52
DC
Bre
mse
AO
-02
Klem
me
X42/
5 Fu
nktio
n
AN
-63
Kl. X
30/8
, Wer
t be
i Bus
steu
erun
gSP
-41
Min
imal
e En
ergi
espa
r-M
agne
tisie
rung
O-0
6 Ti
meo
ut S
teue
rwor
tqu
ittie
ren
O-5
3 St
art
AO
-1#
Ana
loge
inga
ng X
42/1
AN
-64
Kl. X
30/8
, Wer
t be
i Bus
-Tim
eout
SP-4
2 En
ergi
eein
spar
. Min
. Fre
quen
zO
-07
Dia
gnos
e Tr
igge
rO
-54
Reve
rsie
rung
AO
-10
Kl.X
42/1
Ska
l. M
in. S
pann
ung
SP
-43
Mot
or C
os-P
hiO
-1#
Rege
lein
stel
lung
enO
-55
Satz
anw
ahl
AO
-11
Kl.X
42/1
Ska
l. M
ax.S
pann
ung
O-1
0 St
euer
wor
tpro
filO
-56
Fest
sollw
erta
nwah
l
AO
-14
Klem
me
X42/
1 Sk
al. M
in.-S
oll-/
Istw
ert
Zur Programmierung AF-600 FP-Kurzanleitung
DET-759A/D 25
6 6
AO
-15
Klem
me
X42/
1 Sk
al. M
ax.-S
oll-/
Istw
ert
AO
-6#
Ana
loga
usga
ng X
42/1
1PB
-94
Geä
nder
te P
aram
eter
(5)
EN-3
3 CI
P Re
visi
onBN
-73
MS/
TP M
ax. I
nfo-
Fram
es
AO
-16
Klem
me
X42/
1 Fi
lterz
eit
AO
-60
Kl. X
42/1
1 A
nalo
gaus
gang
EN-#
# Et
hern
etEN
-34
CIP
Prod
uktc
ode
BN-7
4 "S
tart
up I
am"
AO
-17
Klem
me
X42/
1 Si
gnal
fehl
erA
O-6
1 Kl
emm
e X4
2/11
Min
. Ska
lieru
ngEN
-0#
IP-E
inst
ellu
ngen
EN-8
# D
iens
teBN
-75
Initi
alis
ieru
ng P
assw
ort
AO
-2#
Ana
loge
inga
ng X
42/3
AO
-62
Kl. X
42/1
1, A
usga
ng m
ax.
Skal
ieru
ngEN
-00
IP-A
dres
szuw
eisu
ngEN
-80
FTP-
Serv
erD
N-#
# D
evic
eNet
-Fel
dbus
AO
-21
Kl.X
42/3
Ska
l. M
ax.S
pann
ung
AO
-63
Klem
me
X42/
11, W
ert
bei
Buss
teue
rung
EN-0
1 IP
-Adr
esse
EN-8
1 H
TTP-
Serv
erD
N-0
# G
rund
eins
tellu
ngen
AO
-21
Kl.X
42/3
Ska
l. M
ax.S
pann
ung
AO
-64
Kl. X
42/1
1, W
ert
bei B
us-T
imeo
utEN
-02
Subn
et M
ask
EN-8
2 SM
TP-S
ervi
ceD
N-0
0 D
evic
eNet
-Pro
toko
ll
AO
-24
Klem
me
X42/
3 Sk
al. M
in.-S
oll-/
Istw
ert
PB-#
# Pr
ofib
usEN
-03
Stan
dard
-Gat
eway
EN-8
9 Tr
ansp
aren
t So
cket
Chan
nel P
ort
DN
-01
Baud
rate
naus
wah
l
AO
-25
Klem
me
X42/
3 Sk
al. M
ax.-S
oll-/
Istw
ert
PB-1
5 PC
D-K
onfig
urat
ion
Sch
reib
enEN
-04
DH
CP-S
erve
rEN
-9#
Erw
eite
rte
Die
nste
DN
-02
MA
C-ID
Adr
esse
AO
-26
Klem
me
X42/
3 Fi
lterz
eit
PB-1
6 PC
D-K
onfig
urat
ion
Les
enEN
-05
Leas
e lä
uft
abEN
-90
Kabe
ldia
gnos
eD
N-0
5 Zä
hler
Übe
rtra
gung
sfeh
ler
AO
-27
Klem
me
X42/
3 Si
gnal
fehl
erPB
-18
Teiln
ehm
erad
ress
eEN
-06
Nam
eser
ver
EN-9
1 M
DI-X
DN
-06
Zähl
er E
mpf
angs
fehl
er
AO
-3#
Ana
loge
inga
ng X
42/5
PB-2
2 Te
legr
amm
typ
EN-0
7 D
omai
n N
ame
EN-9
2 IG
MP-
Snoo
ping
DN
-07
Zähl
er B
us-O
ff
AO
-30
Kl.X
42/5
Ska
l. M
in. S
pann
ung
PB-2
3 Si
gnal
-Par
amet
erEN
-08
Hos
t-N
ame
EN-9
3 Fe
hler
Kab
ellä
nge
DN
-1#
Dev
iceN
et
AO
-31
Kl.X
42/5
Ska
l. M
ax.S
pann
ung
PB-2
7 Pa
ram
eter
bea
rbei
ten
EN-0
9 Ph
ys. A
dres
seEN
-94
Broa
dcas
t St
orm
Sch
utz
DN
-10
Proz
essd
aten
typ
AO
-34
Klem
me
X42/
5 Sk
al. M
in.-S
oll-/
Istw
ert
PB-2
8 Pr
ofib
us S
teue
rung
dea
ktiv
iere
nEN
-1#
Verb
indu
ngEN
-95
Broa
dcas
t St
orm
Filt
er
DN
-11
Proz
essd
aten
Sch
reib
en K
onfig
u-
ratio
n
AO
-35
Klem
me
X42/
5 Sk
al. M
ax.-S
oll-/
Istw
ert
PB-5
3 Pr
ofib
us-W
arnw
ort
EN-1
0 Ve
rb.s
tatu
sEN
-98
Schn
ittst
elle
nzäh
ler
DN
-12
Proz
essd
aten
Les
en K
onfig
u-
ratio
n
AO
-36
Klem
me
X42/
5 Fi
lterz
eit
PB-6
3 A
ktiv
e Ba
udra
teEN
-11
Verb
.dau
erEN
-99
Med
ienz
ähle
rD
N-1
3 W
arnp
aram
eter
AO
-37
Klem
me
X42/
5 Si
gnal
fehl
erPB
-70
Prog
ram
m S
atz
EN-1
2 A
uto.
Ver
bind
ung
LN-#
# LO
NW
ORK
SD
N-1
4 D
evic
eNet
Sol
lwer
t
AO
-4#
Ana
loga
usga
ng X
42/7
PB-7
1 D
aten
wer
te s
peic
hern
EN-1
3 Ve
rb.g
esch
w.
LN-0
# Lo
nWor
ks ID
DN
-15
Dev
iceN
et S
teue
rung
AO
-40
Kl. X
42/7
Ana
loga
usga
ngPB
-72
Freq
.um
r. R
eset
EN-1
4 Ve
rb.d
uple
xLN
-00
Neu
ron
IDD
N-2
# CO
S-Fi
lter
AO
-41
Kl. X
42/7
, Aus
gang
min
. Ska
lieru
ng9-
75 D
O Id
entif
icat
ion
EN-2
# Pr
ozes
sdat
enLN
-1#
LON
-Fun
ktio
nen
DN
-20
COS-
Filte
r 1
AO
-42
Kl. X
42/7
, Aus
gang
max
.
Skal
ieru
ngPB
-80
Def
inie
rte
Para
met
er (1
)EN
-20
Steu
erin
stan
zLN
-10
FU-P
rofil
DN
-21
COS-
Filte
r 2
AO
-43
Klem
me
X42/
7, W
ert
bei
Buss
teue
rung
PB-8
1 D
efin
iert
e Pa
ram
eter
(2)
EN-2
1 Pr
ozes
sdat
en S
chre
iben
Kon
figu-
ratio
nLN
-15
LON
War
nwor
tD
N-2
2 CO
S-Fi
lter
3
AO
-44
Kl. X
42/7
, Wer
t be
i Bus
-Tim
eout
PB-8
2 D
efin
iert
e Pa
ram
eter
(3)
EN-2
2 Pr
ozes
sdat
en L
esen
Kon
figur
atio
nLN
-17
XIF-
Revi
sion
DN
-23
COS-
Filte
r 4
AO
-5#
Ana
loga
usga
ng X
42/9
PB-8
3 D
efin
iert
e Pa
ram
eter
(4)
EN-2
8 D
aten
wer
te s
peic
hern
LN-1
8 Lo
nWor
ks-R
evis
ion
DN
-3#
Para
met
erzu
griff
AO
-50
Kl. X
42/9
Ana
loga
usga
ngPB
-84
Def
inie
rte
Para
met
er (5
)EN
-29
EEPR
OM
spe
iche
rnLN
-2#
LON
Par
am. Z
ugrif
fD
N-3
0 A
rray
Inde
x
AO
-51
Kl. X
42/9
, Aus
gang
min
. Ska
lieru
ngPB
-90
Geä
nder
te P
aram
eter
(1)
EN-3
# Et
herN
et/IP
LN-2
1 D
aten
wer
te s
peic
hern
DN
-31
Dat
enw
erte
spe
iche
rn
AO
-52
Kl. X
42/9
, Aus
gang
max
.Sk
alie
rung
PB-9
1 G
eänd
erte
Par
amet
er (2
)EN
-30
War
npar
amet
erBN
-##
BACn
etD
N-3
2 D
evic
eNet
Rev
isio
n
AO
-53
Klem
me
X42/
9, W
ert
bei
Buss
teue
rung
PB-9
2 G
eänd
erte
Par
amet
er (3
)EN
-31
Dev
iceN
et S
ollw
ert
BN-7
0 BA
Cnet
-Ger
äteb
erei
chD
N-3
3 EE
PRO
M s
peic
hern
AO
-54
Kl. X
42/9
, Wer
t be
i Bus
-Tim
eout
PB-9
3 G
eänd
erte
Par
amet
er (4
)EN
-32
Dev
iceN
et S
teue
rung
BN-7
2 M
S/TP
Max
. Mas
ters
DN
-34
Dev
iceN
et-P
rodu
ktco
de
Zur Programmierung AF-600 FP-Kurzanleitung
26 DET-759A/D
66
ID-#
# In
fo/W
artu
ngID
-42
Span
nung
DR-
12 M
otor
span
nung
DR-
6# A
nzei
g. E
in-/
Aus
g.D
R-95
Erw
. Zus
tand
swor
t 2
ID-0
# Be
trie
bsda
ten
ID-4
3 So
ftw
arev
ersi
onD
R-13
Fre
quen
zD
R-60
Dig
itale
ingä
nge
DR-
96 W
artu
ngsw
ort
ID-0
0 Be
trie
bsst
unde
nID
-44
GE-
Mod
elln
umm
erD
R-14
Mot
orst
rom
DR-
61 A
E 53
Mod
usLG
-##
Prot
okol
le &
E/A
-Sta
tus
ID-0
1 M
otor
lauf
stun
den
ID-4
5 Ty
penc
ode
(akt
uell)
DR-
15 F
requ
enz
[%]
DR-
62 A
nalo
gein
g. 5
3LG
-0#
War
tung
spro
toko
ll
ID-0
2 kW
h-Zä
hler
ID-4
6 G
E Pr
oduk
t-N
r.D
R-16
Dre
hmom
ent
[Nm
]D
R-63
AE
54 M
odus
LG-0
0 W
artu
ngsp
roto
koll:
Pos
.
ID-0
3 A
nzah
l Net
z-Ei
nID
-47
GE
Leis
tung
skar
te-M
odel
l-Nr.
DR-
17 D
rehz
ahl [
UPM
]D
R-64
Ana
loge
ing.
54
LG-0
1 W
artu
ngsp
roto
koll:
Akt
ion
ID-0
4 A
nzah
l Übe
rtem
pera
ture
nID
-48
Tast
enfe
ld-ID
-Nr.
DR-
18 T
herm
. Mot
orsc
hutz
DR-
65 A
nalo
gaus
gang
42
[mA
]LG
-02
War
tung
spro
toko
ll: Z
eit
ID-0
5 A
nzah
l Übe
rspa
nnun
gen
ID-4
9 St
euer
kart
e SW
-Ver
sion
DR-
22 D
rehm
omen
t [%
]D
R-66
Dig
itala
usgä
nge
LG-0
3 W
artu
ngsp
roto
koll:
Dat
um u
ndZe
it
ID-0
6 Re
set
Zähl
er-k
Wh
ID-5
0 Le
istu
ngst
eil S
W-V
ersi
onD
R-3#
Anz
eige
n-FU
DR-
67 P
ulse
ing.
29
[Hz]
LG-1
# N
otfa
llbet
riebs
prot
okol
l
ID-0
7 Re
set
Mot
orla
ufst
unde
nzäh
ler
ID-5
1 Ty
p S
erie
nnum
mer
DR-
30 D
C-Sp
annu
ngD
R-68
Pul
sein
g. 3
3 [H
z]LG
-10
Not
fallb
etrie
bspr
otok
oll:
Erei
gnis
ID-0
8 A
nzah
l der
Sta
rts
ID-5
3 Le
istu
ngst
eil S
erie
nnum
mer
DR-
32 B
rem
slei
stun
g/s
DR-
69 P
ulsa
usg.
27
[Hz]
LG-1
1 N
otfa
llbet
riebs
prot
okol
l: Ze
it
ID-1
# Tr
endd
aten
-Ein
stel
lung
enID
-6#
Inst
all.
Opt
ione
nD
R-33
Bre
msl
eist
ung/
2 m
inD
R-70
Pul
saus
g. 2
9 [H
z]LG
-12
Not
fallb
etrie
bspr
otok
oll:
Dat
umun
d Z
eit
ID-1
0 Tr
endq
uelle
ID-6
0 O
ptio
n in
stal
liert
DR-
34 K
ühlk
örpe
rtem
p.D
R-71
Rel
aisa
usgä
nge
LG-3
# E/
A-O
ptio
nszu
stan
d
ID-1
1 Tr
end-
Abt
astr
ate
ID-6
1 SW
-Ver
sion
Opt
ion
DR-
35 G
erät
etem
pera
tur
DR-
72 Z
ähle
r A
LG-3
0 A
nalo
gein
g. X
42/1
ID-1
2 Ec
htze
itkan
al T
rigge
rere
igni
sID
-62
Opt
ions
best
elln
r.D
R-36
Nen
n-FU
-Str
omD
R-73
Zäh
ler
BLG
-31
Ana
loge
ing.
X42
/3
ID-1
3 Pr
otok
olla
rtID
-63
Opt
ions
serie
nnr.
DR-
37 M
ax. S
trom
Fre
quen
zum
richt
erD
R-75
Ana
loge
ing.
X30
/11
LG-3
2 A
nalo
gein
g. X
42/5
ID-1
4 Ec
htze
itkan
al W
erte
vor
Trig
ger
ID-9
# Pa
ram
eter
info
DR-
38 L
ogic
Con
tr.Z
usta
ndD
R-76
Ana
loge
ing.
X30
/12
LG-3
3 A
nalo
gaus
gang
X42
/7 [V
]
ID-2
# Pr
otok
ollie
rung
ID-9
2 D
efin
iert
e Pa
ram
eter
DR-
39 S
teue
rkar
tent
emp.
DR-
77 A
nalo
gaus
gang
X30
/8[m
A]
LG-3
4 A
nalo
gaus
gang
X42
/9 [V
]
ID-2
0 Pr
otok
oll:
Erei
gnis
ID-9
3 G
eänd
erte
Par
amet
erD
R-40
Tre
ndsp
eich
er v
oll
DR-
8# A
nzei
g. S
chni
ttst
.LG
-35
Ana
loga
usga
ng X
42/1
1 [V
]
ID-2
1 Pr
otok
oll:
Wer
tD
R-##
Dat
enan
zeig
enD
R-43
Sta
tus
Zeitg
este
uert
e A
ktio
nen
DR-
80 B
us S
teue
rwor
t 1
AP-
## H
LK-
Anw
endu
ngsp
aram
.
ID-2
2 Pr
otok
oll:
Zeit
DR-
0# A
nzei
gen-
Allg
emei
nD
R-49
Str
omfe
hler
quel
leD
R-82
Fel
dbus
Sol
lwer
t 1
AP-
0# V
ersc
hied
enes
ID-2
3 Pr
otok
oll:
Dat
um u
nd Z
eit
DR-
00 S
teue
rwor
tD
R-5#
Sol
l- &
Istw
erte
DR-
84 F
eldb
us-K
omm
. Opt
ion
STW
AP-
00 V
erzö
geru
ng e
xt. V
errie
gelu
ng
ID-3
# Fe
hler
spei
cher
DR-
01 S
ollw
ert
[Ein
heit]
DR-
50 E
xter
ner
Sollw
ert
DR-
85 F
C S
teue
rwor
t 1
AP-
2# N
o-Fl
ow E
rken
nung
ID-3
0 Fe
hler
spei
cher
: Feh
lerc
ode
DR-
02 S
ollw
ert
[%]
DR-
52 Is
twer
t [E
inhe
it]D
R-86
FU
Sol
lwer
t 1
AP-
20 L
eist
ung
tie
f A
utok
onfig
.
ID-3
1 Fe
hler
spei
cher
: Wer
tD
R-03
Zus
tand
swor
tD
R-53
Dig
iPot
Sol
lwer
tD
R-9#
Bus
Dia
gnos
eA
P-21
Erf
assu
ng L
eist
ung
tie
f
ID-3
2 Fe
hler
spei
cher
: Zei
tD
R-05
Hau
ptis
twer
t [%
]D
R-54
Istw
ert
1 [E
inhe
it]D
R-90
Ala
rmw
ort
AP-
22 E
rfas
sung
Dre
hzah
l tie
f
ID-3
3 Fe
hler
spei
cher
: Dat
um u
nd Z
eit
DR-
09 B
enut
zerd
ef. A
nzei
geD
R-55
Istw
ert
2 [E
inhe
it]D
R-91
Ala
rmw
ort
2A
P-23
No-
Flow
Fun
ktio
n
ID-4
# Ty
pend
aten
DR-
1# A
nzei
gen-
Mot
orD
R-56
Istw
ert
3 [E
inhe
it]D
R-92
War
nwor
tA
P-24
No-
Flow
Ver
zöge
rung
ID-4
0 FU
-Typ
DR-
10 L
eist
ung
[kW
]D
R-58
PID
-Aus
gang
[%]
DR-
93 W
arnw
ort
2A
P-26
Tro
cken
lauf
funk
tion
ID-4
1 Le
istu
ngst
eil
DR-
11 L
eist
ung
[HP]
D
R-94
Erw
. Zus
tand
swor
tA
P-27
Tro
cken
lauf
verz
öger
ung
Zur Programmierung AF-600 FP-Kurzanleitung
DET-759A/D 27
6 6
AP-
3# N
o-Fl
ow L
eist
ungs
anpa
ssun
gA
P-71
Kom
pres
sors
tart
Max
. Fre
quen
z [H
z]FB
-09
Ala
rmha
ndha
bung
Not
fallb
etrie
bT-
14 D
atum
und
Uhr
zeit
War
tung
CL-0
3 Is
twer
tans
chlu
ss 2
AP-
30 N
o-Fl
ow L
eist
ung
AP-
72 K
ompr
esso
rsta
rt M
ax. A
nlau
fzei
tFB
-1#
FU-B
ypas
sT-
15 W
artu
ngsw
ort
quitt
iere
nCL
-04
Istw
ertu
mw
andl
. 2
AP-
31 L
eist
ungs
korr
ektu
rfak
tor
AP-
73 A
nlau
fbes
chle
unig
ungs
zeit
FB-1
0 FU
-Byp
ass-
Funk
tion
T-16
War
tung
stex
tCL
-05
Aus
gang
sein
heit
Istw
ert
2
AP-
32 D
rehz
ahl t
ief
[UPM
]A
P-75
Kur
zzyk
lus-
Schu
tzFB
-11
Verz
öger
ungs
zeit
FU
-Byp
ass
T-5#
Ene
rgie
prot
okol
lCL
-06
Istw
erta
nsch
luss
3
AP-
33 D
rehz
ahl n
iedr
ig [H
z]A
P-76
Inte
rval
l zw
isch
en S
tart
sFB
-20
Funk
tion
blo
ckie
rter
Rot
orT-
50 E
nerg
iepr
otok
olla
uflö
sung
CL-0
7 Is
twer
tum
wan
dl. 3
AP-
34 L
eist
ung
Dre
hzah
l tie
f [k
W]
AP-
77 M
in. L
aufz
eit
FB-2
1 Bl
ocki
erte
r Ro
tor
Koef
fizie
nt 1
T-51
Zei
trau
mst
art
CL-0
8 A
usga
ngse
inhe
it Is
twer
t 3
AP-
35 L
eist
ung
Dre
hzah
l tie
f [H
P]A
P-8#
Dur
chflu
ssau
sgle
ich
FB-2
2 Bl
ocki
erte
r Ro
tor
Koef
fizie
nt 2
T-53
Ene
rgie
prot
okol
lCL
-12
Soll-
/Istw
erte
inhe
it
AP-
36 D
rehz
ahl h
och
[UPM
]A
P-80
Dur
chflu
ssau
sgle
ich
FB-2
3 Bl
ocki
erte
r Ro
tor
Koef
fizie
nt 3
T-54
Res
et E
nerg
iepr
otok
oll
CL-1
3 M
inim
aler
Sol
l-/Is
twer
t
AP-
37 D
rehz
ahl h
och
[Hz]
AP-
81 Q
uadr
.-lin
eare
Kur
venn
äher
ung
FB-2
4 Bl
ocki
erte
r Ro
tor
Koef
fizie
nt 4
T-6#
Tre
ndda
rste
llung
CL-1
4 M
axim
aler
Sol
l-/Is
twer
t
AP-
38 L
eist
ung
Dre
hzah
l hoc
h [k
W]
AP-
82 A
rbei
tspu
nktb
erec
hn.
FB-3
0 M
otor
ausf
allfu
nktio
nT-
60 T
rend
varia
ble
CL-2
0 Is
twer
tfun
ktio
n
AP-
39 L
eist
ung
Dre
hzah
l hoc
h [H
P]A
P-83
Dre
hzah
l bei
No-
Flow
[UPM
]FB
-31
Mot
orau
sfal
l Koe
ffizi
ent
1T-
61 K
ontin
uier
liche
BIN
-Dat
enCL
-21
Sollw
ert
1
AP-
4# E
nerg
iesp
arm
odus
AP-
84 F
requ
enz
bei N
o-Fl
ow [H
z]FB
-32
Mot
orau
sfal
l Koe
ffizi
ent
2T-
62 G
etim
te B
in-D
aten
CL-2
2 So
llwer
t 2
AP-
40 M
in. L
aufz
eit
AP-
85 D
rehz
ahl a
n A
usle
gung
spun
kt[U
PM]
FB-3
3 M
otor
ausf
all K
oeffi
zien
t 3
T-63
Sta
rt G
etim
ter
Zeitr
aum
CL-2
3 So
llwer
t 3
AP-
41 M
in. E
nerg
iesp
ar-S
topp
zeit
AP-
86 F
req.
an
Aus
legu
ngsp
unkt
[Hz]
FB-3
4 M
otor
ausf
all K
oeffi
zien
t 4
T-64
Sto
pp G
etim
ter
Zeitr
aum
CL-3
# Rü
ckm
eldu
ng E
rw. U
mw
andl
AP-
42 E
nerg
iesp
ar-S
tart
dreh
z. [U
PM]
AP-
87 D
ruck
bei
No-
Flow
-Dre
hzah
lT-
## T
imer
-Fun
ktio
nen
T-65
Min
imal
er B
in-W
ert
CL-3
0 Kä
ltem
ittel
AP-
43 E
nerg
iesp
arst
art-
Dre
hz. [
Hz]
AP-
88 D
ruck
bei
Nen
ndre
hzah
lT-
0# Z
eita
blau
fste
ueru
ngT-
66 R
eset
Kon
tinui
erlic
he B
in-
Dat
enCL
-31
Benu
tzer
def.
Kälte
mitt
el A
1
AP-
44 E
nerg
iest
art-
SW/IW
-Diff
eren
zA
P-89
Dur
chflu
ss a
m A
usle
gung
spun
ktT-
00 E
IN-Z
eit
T-67
Res
et G
etim
te B
in-D
aten
CL-3
2 Be
nutz
erde
f. Kä
ltem
ittel
A2
AP-
45 S
ollw
ert-
Boos
tA
P-90
Dur
chflu
ss b
ei N
ennd
rehz
ahl
T-01
EIN
-Akt
ion
T-8#
Am
ortis
atio
nszä
hler
CL-3
3 Be
nutz
erde
f. Kä
ltem
ittel
A3
AP-
46 M
ax. B
oost
-Zei
tFB
-##
Not
fallb
etrie
bT-
02 A
US-
Zeit
T-80
Sol
lwer
tfak
tor
Leis
tung
CL-3
4 Q
uers
chni
tt L
uftk
anal
1 [m
2]
AP-
5# K
ennl
inie
nend
eFB
-0#
Not
fallb
etrie
bT-
03 A
US-
Akt
ion
T-81
Ene
rgie
kost
enCL
-35
Que
rsch
nitt
Luf
tkan
al 1
[in2
]
AP-
50 K
ennl
inie
nend
efun
ktio
nFB
-00
Not
fallb
etrie
bsfu
nktio
nT-
04 E
reig
nis
T-82
Inve
stiti
onCL
-36
Que
rsch
nitt
Luf
tkan
al 2
[m2]
AP-
51 K
ennl
inie
nend
ever
z.FB
-01
Not
fallb
etrie
bsko
nfig
urat
ion
T-08
Mod
us Z
eitg
este
uert
e A
ktio
nen
T-83
Ene
rgie
eins
paru
ngen
CL-3
7 Q
uers
chni
tt L
uftk
anal
2 [i
n2]
AP-
6# R
iem
enbr
uche
rken
nung
FB-0
2 Ei
nhei
t N
otfa
llbet
rieb
T-09
Rea
ktiv
ieru
ng Z
eitg
est.
Akt
ion
T-84
Kst
.-Ein
spar
.CL
-38
Luft
dich
tefa
ktor
[%]
AP-
60 R
iem
enbr
uchf
unkt
ion
FB-0
3 M
in. S
ollw
ert
Not
fallb
etrie
bT-
1# W
artu
ngCL
-##
PID
-Reg
ler
CL-7
# PI
D A
uto-
Anp
assu
ng
AP-
61 R
iem
enbr
uchm
omen
tFB
-04
Max
. Sol
lwer
t N
otfa
llbet
rieb
T-10
War
tung
spun
ktCL
-0#
Istw
ert
CL-7
0 PI
D-R
egle
rart
AP-
62 R
iem
enbr
uchv
erzö
geru
ngFB
-05
Fest
sollw
ert
Not
fallb
etrie
bT-
11 W
artu
ngsa
ktio
nCL
-00
Istw
erta
nsch
luss
1CL
-71
PID
-Ver
halte
n
AP-
7# V
erdi
chte
rFB
-06
Sollw
ertq
uelle
Not
fallb
etrie
bT-
12 W
artu
ngsz
eitb
asis
CL-0
1 Is
twer
tum
wan
dl. 1
CL-7
2 PI
D-A
usga
ngsä
nder
ung
AP-
70 K
ompr
esso
rsta
rt M
ax. D
rehz
ahl
[UPM
]FB
-07
Istw
ertq
uelle
Not
fallb
etrie
bT-
13 W
artu
ngsz
eitin
terv
all
CL-0
2 A
usga
ngse
inhe
it Is
twer
t 1
CL-7
3 M
in. I
stw
erth
öhe
Zur Programmierung AF-600 FP-Kurzanleitung
28 DET-759A/D
66
CL-7
4 M
axim
ale
Istw
erth
öhe
XC-2
2 Er
w. I
-Zei
t 1
XC-6
4 Er
w. D
-Ver
stär
k./G
renz
e 3
PC-5
2 W
echs
elze
itint
erva
llLC
-43
Logi
kreg
el V
erkn
üpfu
ng 2
CL-7
9 PI
D A
uto-
Anp
assu
ngXC
-23
Erw
. D-Z
eit
1PC
-##
Pum
penr
egle
rPC
-53
Wec
hsel
zeiti
nter
vallg
eber
LC-4
4 Lo
gikr
egel
Boo
lesc
h 3
CL-8
# PI
D-G
rund
eins
tell.
XC-2
4 Er
w. D
-Ver
stär
k./G
renz
e 1
PC-0
# Sy
stem
eins
tellu
ngen
PC-5
4 W
echs
elfe
stze
itLC
-5#
LC-P
rogr
amm
CL-8
1 PI
D-N
orm
al/In
vers
-Reg
elun
gXC
-3#
Erw
. PID
Sol
l-/Is
tw. 2
PC-0
0 Pu
mpe
nreg
ler
PC-5
5 W
echs
el b
ei L
ast
<50%
LC-5
1 Lo
gic
Cont
rolle
r Er
eign
is
CL-8
2 PI
D-S
tart
dreh
zahl
[UPM
]XC
-30
Erw
. Sol
l-/Is
twer
tein
heit
2PC
-02
Mot
orst
art
PC-5
6 Zu
scha
ltmod
us b
ei W
echs
elLC
-52
Logi
c Co
ntro
ller
Akt
ion
CL-8
3 PI
D-S
tart
dreh
zahl
[Hz]
XC-3
1 Er
w. M
inim
aler
Sol
lwer
t 2
PC-0
4 Pu
mpe
nrot
atio
nPC
-58
Verz
öger
ung
Näc
hste
Pum
peB-
## B
rem
sfun
ktio
nen
CL-8
4 Ba
ndbr
eite
Ist=
Sollw
ert
XC-3
2 Er
w. M
axim
aler
Sol
lwer
t 2
PC-0
5 Fe
ste
Führ
ungs
pum
pePC
-59
Verz
öger
ung
Net
zbet
rieb
B-0#
DC
Hal
t/D
C B
rem
se
CL-9
# PI
D-R
egle
rXC
-33
Erw
. var
iabl
er S
ollw
ert
2PC
-06
Anz
ahl d
er P
umpe
nPC
-8#
Stat
usB-
00 D
C-H
alte
stro
m
CL-9
1 PI
D-A
nti-W
indu
pXC
-34
Erw
. Ist
wer
tans
chlu
ss 2
PC-1
0 M
in. L
aufz
eitk
orre
ktur
PC-8
0 Pu
mpe
nzus
tand
B-01
DC-
Brem
sstr
om
CL-9
3 PI
D-P
ropo
rtio
nalv
erst
ärku
ngXC
-35
Erw
. Sol
lwer
t 2
PC-1
1 M
in. L
aufz
eitk
orre
ktur
wer
tPC
-81
Pum
penz
usta
ndB-
02 D
C-Br
emsz
eit
CL-9
4 PI
D In
tegr
atio
nsze
itXC
-37
Erw
. Sol
lwer
t 2
[Ein
heit]
PC-2
# Ba
ndbr
eite
nein
stel
lung
enPC
-82
Führ
ungs
pum
peB-
03 D
C-Br
emse
Ein
[UPM
]
CL-9
5 PI
D-D
iffer
entia
tions
zeit
XC-3
8 Er
w. I
stw
ert
2 [E
inhe
it]PC
-20
Scha
ltban
dbre
itePC
-83
Rela
isst
atus
B-04
DC-
Brem
se E
in [H
z]
CL-9
6 PI
D-P
roze
ss D
-Ver
stär
k./
Gre
nze
XC-3
9 Er
w. A
usga
ng 2
[%]
PC-2
1 Sc
haltg
renz
ePC
-84
Pum
pe E
IN-Z
eit
B-1#
Gen
erat
or. B
rem
sen
XC-#
# Er
w. P
ID-R
egle
rXC
-4#
Erw
. Pro
zess
-PID
2PC
-22
Fest
e D
rehz
ahlb
andb
reite
PC-8
5 Re
lais
EIN
-Zei
tB-
10 B
rem
sfun
ktio
n
XC-0
# Er
w. P
ID-A
uto-
Anp
assu
ngXC
-40
Erw
. Nor
mal
/Inve
rs-R
egel
ung
2PC
-23
SBB
Zus
chal
tver
zöge
rung
PC-8
6 Re
set
Rela
iszä
hler
B-16
AC-
Brem
se m
ax. S
trom
XC-0
0 PI
D-R
egle
rart
XC-4
1 Er
w. P
-Ver
stär
kung
2PC
-24
SBB
Abs
chal
tver
zöge
rung
PC-9
# Se
rvic
eB-
17 Ü
bers
pann
ungs
steu
erun
g
XC-0
1 PI
D-V
erha
lten
XC-4
2 Er
w. I
-Zei
t 2
PC-2
5 Sc
haltv
erzö
geru
ngPC
-90
Pum
penv
errie
gelu
ng
XC-0
2 PI
D-A
usga
ngsä
nder
ung
XC-4
3 Er
w. D
-Zei
t 2
PC-2
6 N
o-Fl
ow A
bsch
altu
ngPC
-91
Man
uelle
r W
echs
el
XC-0
3 M
in. I
stw
erth
öhe
XC-4
4 Er
w. D
-Ver
stär
k./G
renz
e 2
PC-2
7 Zu
scha
ltfun
ktio
nLC
-##
Logi
c Co
ntro
ller
XC-0
4 M
axim
ale
Istw
erth
öhe
XC-5
# Er
w. P
ID S
oll-/
Istw
. 3PC
-28
Zusc
haltf
unkt
ions
zeit
LC-0
# LC
-Ein
stel
lung
en
XC-0
9 PI
D A
uto-
Anp
assu
ngXC
-50
Erw
. Sol
l-/Is
twer
tein
heit
3PC
-29
Abs
chal
tfun
ktio
nLC
-00
Logi
c Co
ntro
ller
XC-1
# Er
w. P
ID S
oll-/
Istw
. 1XC
-51
Erw
. Min
imal
er S
ollw
ert
3PC
-30
Abs
chal
tfun
ktio
nsze
itLC
-01
SL-C
ontr
olle
r St
art
XC-1
0 Er
w. S
oll-/
Istw
erte
inhe
it 1
XC-5
2 Er
w. M
axim
aler
Sol
lwer
t 3
PC-4
# Zu
scha
ltein
stel
l.LC
-02
SL-C
ontr
olle
r St
opp
XC-1
1 Er
w. M
inim
aler
Sol
lwer
t 1
XC-5
3 Er
w. v
aria
bler
Sol
lwer
t 3
PC-4
0 Ve
rzög
erun
gsra
mpe
LC-0
3 LC
-Par
amet
er In
itial
isie
ren
XC-1
2 Er
w. M
axim
aler
Sol
lwer
t 1
XC-5
4 Er
w. I
stw
erta
nsch
luss
3PC
-41
Besc
hleu
nigu
ngsr
ampe
LC-1
# Ve
rgle
iche
r
XC-1
3 Er
w. v
aria
bler
Sol
lwer
t 1
XC-5
5 Er
w. S
ollw
ert
3PC
-42
Zusc
halts
chw
elle
LC-1
0 Ve
rgle
iche
r-O
pera
nd
XC-1
4 Er
w. I
stw
erta
nsch
luss
1XC
-57
Erw
. Sol
lwer
t 3
[Ein
heit]
PC-4
3 A
bsch
alts
chw
elle
LC-1
1 Ve
rgle
iche
r-Fu
nktio
n
XC-1
5 Er
w. S
ollw
ert
1XC
-58
Erw
. Ist
wer
t 3
[Ein
heit]
PC-4
4 Zu
scha
ltdre
hzah
l [U
PM]
LC-1
2 Ve
rgle
iche
r-W
ert
XC-1
7 Er
w. S
ollw
ert
1 [E
inhe
it]XC
-59
Erw
. Aus
gang
3 [%
]PC
-45
Zusc
haltd
rehz
ahl [
Hz]
LC-2
# Ti
mer
XC-1
8 Er
w. I
stw
ert
1 [E
inhe
it]XC
-6#
Erw
. Pro
zess
-PID
3PC
-46
Abs
chal
tdre
hzah
l [U
PM]
LC-2
0 LC
-Tim
er
XC-1
9 Er
w. A
usga
ng 1
[%]
XC-6
0 Er
w. N
orm
al/In
vers
-Reg
elun
g 3
PC-4
7 A
bsch
altd
rehz
ahl [
Hz]
LC-4
# Lo
gikr
egel
n
XC-2
# Er
w. P
roze
ss-P
ID 1
XC-6
1 Er
w. P
-Ver
stär
kung
3PC
-5#
Wec
hsel
eins
tell.
LC-4
0 Lo
gikr
egel
Boo
lesc
h 1
XC-2
0 Er
w. N
orm
al/In
vers
-Reg
elun
g1
XC-6
2 Er
w. I
-Zei
t 3
PC-5
0 Fü
hr.-P
umpe
n-W
chsl
LC-4
1 Lo
gikr
egel
Ver
knüp
fung
1
XC-2
1 Er
w. P
-Ver
stär
kung
1XC
-63
Erw
. D-Z
eit
3PC
-51
Wec
hsel
erei
gnis
LC-4
2 Lo
gikr
egel
Boo
lesc
h 2
Zur Programmierung AF-600 FP-Kurzanleitung
DET-759A/D 29
6 6
6.2 Externe Programmierung mit DCT-10
GE stellt ein Softwareprogramm zur Verfügung, mit demProgramme zur Programmierung des Frequenzumrichtersentwickelt, gespeichert und übertragen werden können.Mithilfe der DCT-10 können Sie einen PC an denFrequenzumrichter anschließen und ihn online program-mieren, statt das Tastatur zu benutzen. Zudem kann diegesamte Programmierung des Frequenzumrichters offlineerfolgen und dann einfach in den Frequenzumrichterübertragen werden. Alternativ kann das gesamteFrequenzumrichterprofil zur Speicherung oder Analyse aufden PC geladen werden.
Zum Anschluss an den Frequenzumrichter stehen der USB-Anschluss und die RS-485-Klemme zur Verfügung.
Nähere Informationen finden Sie unterwww.geelectrical.com/drives
Zur Programmierung AF-600 FP-Kurzanleitung
30 DET-759A/D
66
7 Warnungen und Alarmmeldungen
7.1 Definitionen von Warn-/Alarmmeldungen
Tabelle 7.1 legt fest, ob vor einem Alarm eine Warnung ausgegeben wird, und ob der Alarm den Frequenzumrichterabschaltet oder eine Abschaltblockierung erfolgt.
Nr. Beschreibung Warnung
Alarm/Abschaltung
Alarm/Abschaltblo-ckierung
Parameterbezeichnung
1 10 Volt niedrig X 2 Signalfehler (X) (X) AN-01 Signalausfall
Funktion4 Netzunsymmetrie (X) (X) (X) SP-12 Netzphasen-
Unsymmetrie5 DC-Spannung hoch X 6 DC-Spannung niedrig X 7 DC-Überspannung X X 8 DC-Unterspannung X X 9 WR-Überlast X X 10 Motortemperatur Elektronisch-thermische
Überlast(X) (X) F-10 Elektronische
Überlast11 Motor Thermistor (X) (X) F-10 Elektronische
Überlast12 Moment.grenze X X 13 Überstrom X X X 14 Erdschluss X X X 15 Inkompatible Hardware X X 16 Kurzschluss X X 17 Steuerwort-Timeout (X) (X) O-04 Steuerwort
Timeout-Funktion18 Startfehler 23 Interne Lüfter X 24 Externe Lüfter X SP-53 Lüfterüber-
wachung29 Umrichter Übertemperatur X X X 30 Motorphase U fehlt (X) (X) (X) H-78 Motorphasen
Überwachung31 Motorphase V fehlt (X) (X) (X) H-78 Motorphasen
Überwachung32 Motorphase W fehlt (X) (X) (X) H-78 Motorphasen
Überwachung33 Inrush Fehler X X 34 Feldbus-Fehler X X 35 Optionsfehler X X 36 Netzausfall X X 38 Interner Fehler X X 39 Kühlkörpersensor X X 40 Digitalausgang 27 ist überlastet (X) E-00 Schaltlogik,
E-51 Klemme 27Funktion
41 Digitalausgang 29 ist überlastet (X) E-00 Schaltlogik,E-52 Klemme 29
Funktion42 Digitalausgang X30/6 ist überlastet (X) E-56 Kl. X30/6 Digital-
ausgang (OPCGPIO)42 Digitalausgang X30/7 ist überlastet (X) E-57 Kl. X30/7 Digital-
ausgang (OPCGPIO)45 45 Erdschluss 2
Warnungen und Alarmmeldunge... AF-600 FP-Kurzanleitung
DET-759A/D 31
7 7
Nr. Beschreibung Warnung
Alarm/Abschaltung
Alarm/Abschaltblo-ckierung
Parameterbezeichnung
46 Umrichter Versorgung X X 47 24-V-Fehler X X X 48 1,8-V-Fehler X X 49 Drehzahlgrenze X (X) H-36 Min. Abschaltd-
rehzahl [UPM]50 Auto Tune-Kalibrierungsfehler X 51 Auto Tune Motordaten überprüfen X 52 Auto Tune Motornennstrom X 53 Auto Tune-Motor zu groß X 54 Auto Tune-Motor zu klein X 55 Auto Tune Parameter außerhalb der
Toleranz X
56 Auto Tune durch Benutzer abgebrochen X 57 Auto Tune-Timeout X 58 Auto Tune interner Fehler X X 59 Stromgrenze X 60 Externe Verriegelung X 62 Ausgangsfrequenz Grenze X 64 Motorspannung Grenze X 65 Steuerkarte Übertemperatur X X X 66 Temperatur zu niedrig X 67 Optionen neu X 69 Umr. Übertemperatur X X 70 Ungültige Frequenzumrichter-Konfigu-
ration X
76 Leistungsteil Konfiguration X 79 Ung. LT-Konfig. X X 80 Initialisiert X 91 AI54 Einstellungsfehler X 92 Kein Durchfluss X X AP-2#93 Trockenlauf X X AP-2#94 Kennlinienende X X AP-5#95 Riemenbruch X X AP-6#96 Startverzögerung X AP-7#97 Stoppverzögerung X AP-7#98 Uhrfehler X K-7#201 Notfallbetrieb war aktiv 202 Über Grenzw. Notfallb. 203 Motor fehlt 204 Blockierter Rotor 243 Bremse IGBT X X 244 Kühlkörpertemperatur X X X 245 Kühlkörpersensor X X 246 Umrichter Versorgung X X 247 Umr.Übertemp. X X 248 Ung. LT-Konfig. X X 250 Neues Ersatzteil X 251 Typencode neu X X
Tabelle 7.1 Liste der Alarm-/Warncodes
(X) Parameterabhängig1) Autom. Quittieren über H-04 Autom. Quitt. (x) nicht möglich
HINWEISEine detaillierte Beschreibung sowie Hilfe zur Fehlersuche und -behebung finden Sie im AF-600 FP Produkthandbuch.
Warnungen und Alarmmeldunge... AF-600 FP-Kurzanleitung
32 DET-759A/D
77
8 Technische Daten
8.1 Allgemeine technische Daten
Netzversorgung (L1, L2, L3):Versorgungsspannung 200-240 V ±10 %, 380-480 V ±10 %, 525-600 V ±10 %, 525-690 V ±10 %
Niedrige Netzspannung/Netzausfall:Bei niedriger Netzspannung oder Netzausfall arbeitet der Frequenzumrichter weiter, bis die Spannung des Zwischenkreises unterden minimalen Stopppegel abfällt - normalerweise 15 % unter der niedrigsten Versorgungsnennspannung des Frequenzum-richters. Bei einer Netzspannung unter 10 % der niedrigsten Versorgungsnennspannung des Frequenzumrichters kann keineEinschaltung mit vollem Drehmoment erwartet werden.
Netzfrequenz 50/60 Hz ±5 %Max. kurzzeitiges Ungleichgewicht zwischen Netzphasen 3,0 % der VersorgungsnennspannungVerzerrungsleistungsfaktor () ≥ 0,9 bei NennlastVerschiebungsleistungsfaktor (cos) nahe 1 (> 0,98)Schalten am Netzeingang L1, L2, L3 (Netz-Ein) ≤ 7,5 kW / 10 HP und darunter max. 2 x/Min.Schalten am Netzeingang L1, L2, L3 (Netz-Ein) ≥ 7,5 kW / 10 HP und darunter max. 1 x/Min.Schalten am Netzeingang L1, L2, L3 (Netz-Ein) ≥ 110 kW / 150 HP und darüber Max. 1 x/2 Min.Umgebung nach EN 60664-1 Überspannungskategorie III / Verschmutzungsgrad 2
Das Gerät eignet sich für Netzversorgungen, die maximal 100.000 ARMS (symmetrisch) bei maximal je 240/480/600 V liefernkönnen.
Motorausgang (U, V, W):Ausgangsspannung 0-100 % der VersorgungsspannungAusgangsfrequenz (0,25-75 kW)/(75 kW) 0-1000 HzAusgangsfrequenz (90-1000 kW)(90 kW) 0-8001)HzAusgangsfrequenz bei Fluxvektorbetrieb 0-300 HzSchalten am Ausgang UnbegrenztRampenzeiten 0,01-3600 s
1) Spannungs- und leistungsabhängig
Drehmomentverhalten der Last:Startdrehmoment (konstantes Drehmoment) maximal 160 % für 60 S1)
Startdrehmoment maximal 180 % bis zu 0,5 s1)
Überlastmoment (konstantes Drehmoment) maximal 160 % für 60 S1)
Startdrehmoment (quadratisches Drehmoment) maximal 110 % für 60 s1)
Überlastmoment (quadratisches Drehmoment) maximal 110 % für 60 s
Drehmomentanstiegzeit in (unabhängig von fsw) 10 msDrehmomentanstiegzeit bei Flux-Vektorbetrieb (bei 5 kHz fsw) 1 ms
1) Prozentwert entspricht dem Nenndrehmoment.2) Die Drehmomentantwortzeit hängt von der Anwendung und der Last ab, aber als allgemeine Regel gilt, dass der Drehmoment-schritt von 0 bis zum Referenzwert das Vier- bis Fünffache der Drehmomentanstiegzeit beträgt.
Kabellängen und Querschnitte:Max. Motorkabellänge, abgeschirmtes Kabel 150 mMax. Motorkabellänge, nicht abgeschirmt 300 mMax. Querschnitt für Steuerklemmen, starrer Draht 1,5 mm2/16 AWG (2 x 0,75 mm2)Max. Querschnitt für Steuerklemmen, flexibles Kabel 1 mm2/18 AWGMax. Querschnitt für Steuerklemmen, Kabel mit Aderendhülse 0,5 mm2/20 AWGMin. Querschnitt für Steuerklemmen 0,25 mm2
Technische Daten AF-600 FP-Kurzanleitung
DET-759A/D 33
8 8
Digitaleingänge:Programmierbare Digitaleingänge 4 (6)1)
Klemmennummer 18, 19, 271), 291), 32, 33,Logik PNP oder NPNSpannungsbereich 0-24 V DCSpannungsniveau, logisch „0“ PNP < 5 V DCSpannungsniveau, logisch „1“ PNP > 10 V DCSpannungsniveau, logisch „0“ NPN2) > 19 V DCSpannungsniveau, logisch „1“ NPN2) < 14 V DCMaximale Spannung am Eingang 28 V DCPulsfrequenzbereich 0-110 kHz(Arbeitszyklus) Min. Pulsbreite 4,5 msEingangswiderstand, Ri ca. 4 kΩAnalogeingänge:Anzahl Analogeingänge 2Klemmennummer 53, 54Betriebsarten Spannung oder StromBetriebsartwahl Schalter S201 und Schalter S202Einstellung Spannung Schalter S201/Schalter S202 = AUS (U)Spannungsniveau -10 bis +10 V DC (skalierbar)Eingangswiderstand, Ri ca. 10 kΩMax. Spannung ± 20 VEinstellung Strom Schalter S201/Schalter S202 = EIN (I)Strombereich 0/4 bis 20 mA (skalierbar)Eingangswiderstand, Ri ca. 200 ΩMax. Strom 30 mAAuflösung der Analogeingänge 10 Bit (+ Vorzeichen)Genauigkeit der Analogeingänge Max. Abweichung 0,5 % der GesamtskalaBandbreite 100 Hz
Die Analogeingänge sind galvanisch von der Versorgungsspannung (PELV) und anderen Hochspannungsklemmen getrennt.
Puls-/Drehgeber-Eingänge:Programmierbare Puls-/Drehgeber-Eingänge 2/1Klemmennummer Puls-/Drehgeber 29, 331) / 322), 332)
Max. Frequenz an Klemme 29, 32, 33 110 kHz (Gegentakt)Max. Frequenz an Klemme 29, 32, 33 5 kHz (offener Kollektor)Min. Frequenz an Klemme 29, 32, 33 4 HzSpannungsniveau siehe DigitaleingängeMaximale Spannung am Eingang 28 V DCEingangswiderstand, Ri ca. 4kΩPulseingangsgenauigkeit (0,1-1 kHz) Max. Abweichung: 0,1 % der GesamtskalaGenauigkeit des Drehgebereingangs (1-11 kHz) Max. Abweichung: 0,05 % der Gesamtskala
Die Puls- und Drehgebereingänge (Klemmen 29, 32, 33) sind galvanisch von der Versorgungsspannung PELV (Schutzklein-spannung – Protective extra low voltage) und anderen Hochspannungsklemmen getrennt.1) Pulseingänge sind 29 und 332) Drehgebereingänge: 32 = A und 33 = B
Technische Daten AF-600 FP-Kurzanleitung
34 DET-759A/D
88
Analogausgänge:Anzahl programmierbarer Analogausgänge 1Klemmennummer 42Strombereich am Analogausgang 0/4-20 mAMax. Last GND – Analogausgang 500 ΩGenauigkeit am Analogausgang Max. Abweichung: 0,5 % der GesamtskalaAuflösung am Analogausgang 12 Bit
Der Analogausgang ist galvanisch von der Versorgungsspannung (PELV = Protective extra low voltage / Schutzkleinspannung)und anderen Hochspannungsklemmen getrennt.
Steuerkarte, RS-485 serielle Schnittstelle:Klemmennummer 68 (P,TX+, RX+), 69 (N,TX-, RX-)Klemmennummer 61 Masse für Klemmen 68 und 69
Die serielle RS-485-Schnittstelle ist von anderen zentralen Stromkreisen funktional und von der Versorgungsspannung (PELV)galvanisch getrennt.
Digitalausgänge:Programmierbare Digital-/Pulsausgänge 2Klemmennummer 27, 29 1)
Spannungsbereich am Digital-/Pulsausgang 0-24 VMax. Ausgangsstrom (Körper oder Quelle) 40 mAMax. Last am Pulsausgang 1 kΩMax. kapazitive Last am Pulsausgang 10 nFMin. Ausgangsfrequenz am Pulsausgang 0 HzMax. Ausgangsfrequenz am Pulsausgang 32 kHzGenauigkeit am Pulsausgang Max. Abweichung: 0,1 % der GesamtskalaAuflösung der Pulsausgänge 12 Bit
1) Die Klemmen 27 und 29 können auch als Eingang programmiert werden.
Der Digitalausgang ist galvanisch von der Versorgungsspannung (PELV) und anderen Hochspannungsklemmen getrennt.
Steuerkarte, 24 V DC-Ausgang:Klemmennummer 12, 13Ausgangsspannung 24 V +1, -3 VMax. Last 200 mA
Die 24-V-DC-Versorgung ist galvanisch von der Versorgungsspannung (PELV) getrennt, hat jedoch das gleiche Potential wie dieAnalog- und Digitalein- und -ausgänge.
Technische Daten AF-600 FP-Kurzanleitung
DET-759A/D 35
8 8
Relaisausgang:Programmierbare Relaisausgänge 2 Form CKlemmennummer Relais 01 1-3 (öffnen), 1-2 (schließen)Max. Klemmenleistung (AC-1)1) an 1-3 (öffnen), 1-2 (schließen) (ohmsche Last) 240 V AC, 2 AMax. Klemmenleistung (AC-15)1) (induktive Last @ cosφ 0,4) 240 V AC, 0,2 AMax. Klemmenleistung (DC-1)1) an 1-2 (schließen), 1-3 (öffnen) (ohmsche Last) 60 V DC, 1 AMax. Klemmenleistung (DC-13)1) (induktive Last) 24 V DC, 0,1 AKlemmennummer Relais 02 4-6 (öffnen), 4-5 (schließen)Max. Klemmenleistung (AC-1)1) an 4-5 (NO) (ohmsche Last)2)3) Überspannungs-Kat. II 400 V AC, 2 AMax. Klemmenleistung (AC-15)1) an 4-5 (NO) (induktive Last @ cosφ 0,4) 240 V AC, 0,2 AMax. Klemmenleistung (DC-1)1) an 4-5 (schließen) (ohmsche Last) 80 V DC, 2 AMax. Klemmenleistung (DC-13)1) an 4-5 (schließen) (induktive Last) 24 V DC, 0,1 AMax. Klemmenleistung (AC-1)1) an 4-6 (öffnen) (ohmsche Last) 240 V AC, 2 AMax. Klemmenleistung (AC-15)1) auf 4-6 (NC/Öffner) (induktive Last bei cosφ 0,4) 240 V AC, 0,2 AMax. Klemmenleistung (DC-1)1) an 4-6 (öffnen) (ohmsche Last) 50 V DC, 2 AMax. Klemmenleistung (DC-13)1) an 4-6 (öffnen) (induktive Last) 24 V DC, 0,1 AMin. Klemmenleistung an 1-3 (öffnen), 1-2 (schließen), 4-6 (öffnen), 4-5 (schließen) 24 V DC 10 mA, 24 V AC 20 mAUmgebung nach EN 60664-1 Überspannungskategorie III/Verschmutzungsgrad 2
1) IEC 60947 Teil 4 und 5Die Relaiskontakte sind durch verstärkte Isolierung (PELV – Protective extra low voltage/Schutzkleinspannung) vom Rest derSchaltung galvanisch getrennt.2) Überspannungskategorie II3) UL-Anwendungen 300 V AC 2 A
Steuerkarte, 10 V DC-Ausgang:Klemmennummer 50Ausgangsspannung 10,5 V ±0,5 VMax. Last 15 mA
Die 10-V-DC-Versorgung ist von der Versorgungsspannung (PELV (Schutzkleinspannung - Protective extra low voltage)) undanderen Hochspannungsklemmen galvanisch getrennt.
Steuerungseigenschaften:Auflösung der Ausgangsfrequenz bei 0-1000 Hz ± 0,003 HzWiederholgenauigkeit für Präz. Start/Stopp (Klemmen 18, 19) ≤± 0,1 msSystem-Reaktionszeit (Klemmen 18, 19, 27, 29, 32, 33) ≤ 2 msDrehzahlregelbereich (ohne Rückführung) 1:100 der SynchrondrehzahlDrehzahlregelbereich (mit Rückführung) 1:1000 der SynchrondrehzahlDrehzahlgenauigkeit (ohne Rückführung) 30 - 4000 UPM: Abweichung ±8 UPMDrehzahlgenauigkeit (mit Rückführung), je nach Auflösung des Istwertgebers 0 - 6000 UPM: Abweichung ±0,15 UPMDrehmomentregelgenauigkeit (Drehzahlrückführung) max. Abweichung±5 % der Gesamtskala
Alle Angaben zu Steuerungseigenschaften basieren auf einem 4-poligen Asynchronmotor
Technische Daten AF-600 FP-Kurzanleitung
36 DET-759A/D
88
Umgebung:Vibrationstest alle Gehäuse 1,0 gRelative Luftfeuchtigkeit 5 % - 95 % (IEC 721-3-3; Klasse 3K3 (nicht kondensierend) bei BetriebAggressive Umgebungsbedingungen (IEC 60068-2-43) H2S-Test Prüfung kDPrüfverfahren nach IEC 60068-2-43 Hydrogensulfid (10 Tage)Umgebungstemperatur (bei 60° AVM Schaltmodus)- mit Leistungsreduzierung max. 50 °C1)
- bei voller Ausgangsleistung typischer EFF2-Motoren (bis zu 90 % Ausgangsstrom) max. 50 °C1)
- bei vollständigem Dauerausgangsstrom des FU max. 45 °C1)
1) Zur Leistungsreduzierung siehe AF-600 FP Projektierungshandbuch, Abschnitt Besondere Bedingungen.
Min. Umgebungstemperatur bei Volllast 0°CMin. Umgebungstemperatur bei reduzierter Leistung - 10 °CTemperatur bei Lagerung/Transport -25 - +65/70 °CMax. Höhe über dem Meeresspiegel ohne Leistungsreduzierung 1000 mMax. Höhe über dem Meeresspiegel mit Leistungsreduzierung 3000 m
Zur Leistungsreduzierung aufgrund von hohem Luftdruck siehe Abschnitt Besondere Bedingungen
EMV-Normen, Störaussendung EN 61800-3, EN 61000-6-3/4, EN 55011, IEC 61800-3
EMV-Normen, StörfestigkeitEN 61800-3, EN 61000-6-1/2,
EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6Steuerkartenleistung:Abtastintervall 1 msSteuerkarte, USB serielle Schnittstelle:USB-Standard 1.1 (Full Speed)USB-Stecker USB-Stecker Typ B (Gerät)
Die Verbindung zum PC erfolgt über ein standardmäßiges Host/Geräte-USB-Kabel.Die USB-Verbindung ist galvanisch von der Versorgungsspannung (PELV, Schutzkleinspannung) und anderen Hochspannungs-klemmen getrennt.Der USB-Erdanschluss ist nicht galvanisch von der Schutzerde getrennt. Verwenden Sie nur einen isolierten Laptop für die USB-Verbindung mit dem Frequenzumrichter.
Schutz und Funktionen:
• Elektronischer thermischer Motor-Überlastschutz.
• Die Temperaturüberwachung des Kühlkörpers stellt sicher, dass der Frequenzumrichter abgeschaltet wird, wenndie Temperatur einen vordefinierten Wert erreicht. Eine Überlastabschaltung durch hohe Temperatur kann erstzurückgesetzt werden, nachdem die Kühlkörpertemperatur wieder unter die in den folgenden Tabellen festge-legten Werte gesunken ist (dies ist nur eine Richtschnur: Temperaturen können je nach Leistungsgröße,Gerätegröße, Schutzart usw. verschieden sein).
• Der Frequenzumrichter ist gegen Kurzschlüsse an Motorklemmen U, V, W geschützt.
• Wenn eine Netzphase fehlt, schaltet der Frequenzumrichter ab oder gibt eine Warnung aus (abhängig von derLast).
• Die Überwachung der Zwischenkreisspannung stellt sicher, dass der Frequenzumrichter abgeschaltet wird, wenndie Zwischenkreisspannung zu gering oder zu hoch ist.
• Der Frequenzumrichter überprüft ständig, ob kritische Werte von Innentemperatur, Laststrom, Hochspannung imZwischenkreis oder niedrige Motordrehzahlen vorliegen. Als Reaktion auf einen kritischen Wert kann derFrequenzumrichter die Taktfrequenz anpassen und/oder den Schaltmodus zur Leistungssicherung desFrequenzumrichters ändern.
Technische Daten AF-600 FP-Kurzanleitung
DET-759A/D 37
8 8
8.2.1 Sicherungen
Es wird empfohlen, versorgungsseitig Sicherungen und/oder Trennschalter als Schutz bei Defekt von Bauteilen imFrequenzumrichter (erster Fehler) zu verwenden.
HINWEISDies ist obligatorisch, um Übereinstimmung mit IEC 60364 für CE oder NEC 2009 für UL sicherzustellen.
WARNUNGPersonal und Anlagen müssen gegen die Folgen eines Bauteildefekts im Frequenzumrichter geschützt werden.
AbzweigschutzZum Schutz der Installation vor elektrischen Gefahren und Bränden müssen alle Abzweigkreise in einer Installation, inGetrieben, Maschinen usw. gemäß nationalen und internationalen Richtlinien vor Kurzschluss und Überstrom geschützt sein.
HINWEISDie gegebenen Empfehlungen bieten keinen Abzweigschutz zur Erfüllung der UL-Anforderungen.
Kurzschluss-Schutz:GE empfiehlt die Verwendung der unten aufgeführten Sicherungen / Trennschalter zum Schutz von Wartungspersonal undGegenständen im Falle einer Bauteilstörung im Frequenzumrichter.
Überstromschutz:Der Frequenzumrichter bietet Überlastschutz, um Lebensgefahren zu begrenzen und Sachschäden sowie Brandgefahraufgrund überhitzender Kabel in der Installation zu vermeiden. Der Frequenzumrichter verfügt über einen externenÜberstromschutz (F-43 Stromgrenze), der zum vorgeschalteten Überlastschutz verwendet werden kann (außer für UL-Anwendungen). Darüber hinaus können Sicherungen oder Trennschalter verwendet werden, um der Installation denerforderlichen Überstromschutz zu bieten. Überstromschutz muss immer gemäß den einschlägigen Vorschriften ausgeführtwerden.
WARNUNGIm Falle einer Fehlfunktion kann das Nichtbeachten der Empfehlung zu Gefahren für den Bediener und Schäden amFrequenzumrichter und anderen Geräten führen.
In den folgenden Tabellen werden die empfohlenen Nennströme aufgelistet. Empfohlene Sicherungen für kleine bis mittlereLeistungsgrößen entsprechen dem Typ gG. Bei größeren Leistungen werden aR-Sicherungen empfohlen. Leistrungstrenn-schalter können unter der Voraussetzung verwendet werden, dass sie die dem Frequenzumrichter zugeführte Energie aufein Niveau begrenzen, das dem der Sicherungen entspricht oder niedriger ist.Wenn Sicherungen/Trennschalter gemäß den Empfehlungen verwendet werden, werden mögliche Schäden am Frequen-zumrichter hauptsächlich auf Schäden innerhalb des Geräts beschränkt.
8.2.2 CE-Konformität
Sicherungen und Trennschalter müssen zwingend der IEC 60364 entsprechen. GE empfiehlt die Auswahl eines der folgendenElemente.
Die unten stehenden Sicherungen sind für die Verwendung in einer Schaltung geeignet, die 100.000 Aeff (symmetrisch),240 V, 480 V, 500 V oder 600 V liefert (je nach Nennspannung des Frequenzumrichters). Mit der korrekten Sicherung liegtder Nennkurzschlussstrom (SCCR) des Frequenzumrichters bei 100.000 Aeff.
Technische Daten AF-600 FP-Kurzanleitung
38 DET-759A/D
88
AF-600 3-phasig Empfohlene Sicherungsgröße Empfohlene maximale Sicherung
[kW]
0,75
gG-16 gG-251,5
2,2
3,7 gG-20 gG-32
5,5
gG-50 gG-637,5
11
15gG-80 gG-125
18,5
22 gG-125 gG-150
30 aR-160 aR-160
37 aR-200 aR-200
45 aR-250 aR-250
Tabelle 8.1 200-240 V, IP20
AF-600 3-phasig Empfohlene Sicherungsgröße Empfohlene maximale Sicherung
[kW]
0,75
gG-20 gG-321,5
2,2
3,7
5,5
gG-63 gG-807,5
11
15 gG-80 gG-100
18,5gG-125 gG-160
22
30 aR-160 aR-160
37 aR-200 aR-200
45 aR-250 aR-250
Tabelle 8.2 IP55/NEMA 12 und IP66/NEMA 4/4X Innenräume
Technische Daten AF-600 FP-Kurzanleitung
DET-759A/D 39
8 8
AF-600 3-phasig Empfohlene Sicherungsgröße Empfohlene maximale Sicherung
[kW]
0,75
gG-16 gG-251,5
2,2
3,7
5,5gG-20 gG-32
7,5
11
gG-50 gG-6315
18,5
22
gG-80 gG-12530
37
45 gG-125 gG-150
55 aR-160 aR-160
75aR-250 aR-250
90
110 gG-300 gG-300
132 gG-350 gG-350
160 gG-400 gG-400
200 gG-500 gG-500
250 gG-630 gG-630
315 aR-700 aR-700
355
aR-900 aR-900400
450
500aR-1600 aR-1600
560
630aR-2000 aR-2000
710
800aR-2500 aR-2500
1000
Tabelle 8.3 380-480 V, IP20
Technische Daten AF-600 FP-Kurzanleitung
40 DET-759A/D
88
AF-600 3-phasig Empfohlene Sicherungsgröße Empfohlene maximale Sicherung
[kW]
0,75 gG-20 gG-32
1,5
2,2
3,7
5,5
7,5
11 gG-50 gG-80
15
18,5
22 gG-80 gG-100
30
37 gG-125 gG-160
45
55
75 aR-250 aR-250
90
110 gG-300 gG-300
132 gG-350 gG-350
160 gG-400 gG-400
200 gG-500 gG-500
250 gG-630 gG-630
315 aR-700 aR-700
355
aR-900 aR-900400
450
500aR-1600 aR-1600
560
630aR-2000 aR-2000
710
800aR-2500 aR-2500
1000
Tabelle 8.4 380-480 V, IP55
Technische Daten AF-600 FP-Kurzanleitung
DET-759A/D 41
8 8
AF-600 3-phasig Empfohlene Sicherungsgröße Empfohlene maximale Sicherung
[kW]
0,75
gG-10 gG-251,5
2,2
3,7
5,5gG-16 gG-32
7,5
11
gG-35 gG-6315
18,5
22
gG-63 gG-12530
37
45gG-100 gG-150
55
75aR-250 aR-250
90
Tabelle 8.5 525-600 V, IP20
AF-600 3-phasig Empfohlene Sicherungsgröße Empfohlene maximale Sicherung
[kW]
0,75
gG-16 gG-32
1,5
2,2
3,7
5,5
7,5
11
gG-35 gG-8015
18,5
22gG-50 gG-100
30
37gG-125 gG-160
45
55
aR-250 aR-25075
90
Tabelle 8.6 525-600 V, IP55
Technische Daten AF-600 FP-Kurzanleitung
42 DET-759A/D
88
AF-600 3-phasig Empfohlene SicherungsgrößeEmpfohlene maximale
Sicherung
[kW]
11 gG-25
gG-6315
gG-3218.5
22 gG-40
30gG-63
gG-80
37 gG-100
45 gG-80 gG-125
55 gG-100
gG-16075gG-125
90
110 aR-250 aR-250
132 aR-315 aR-315
160aR-350 aR-350
200
250 aR-400 aR-400
315 aR-500 aR-500
400 aR-550 aR-550
450aR-700 aR-700
500
560aR-900 aR-900
630
710
aR-1600 aR-1600800
900
1000
1200 aR-2000 aR-2000
1400 aR-2500 aR-2500
Tabelle 8.7 525-690 V, IP21/Nema 1 and IP55/Nema 12
Technische Daten AF-600 FP-Kurzanleitung
DET-759A/D 43
8 8
8.2.3 NEC- und UL-Konformität
Sicherungen und Trennschalter müssen obligatorisch der NEC 2009 entsprechen. Wir empfehlen die Auswahl eines derfolgenden Bauteile.
Das Schaltvermögen der nachstehenden Sicherungen ist für 100.000 Arms (symmetrisch) bei 240 V, 480 V oder 600 V,abhängig von der Nennspannung des Frequenzumrichters, ausgelegt. Bei Verwendung der richtigen Sicherungen ist dieKurzschlussstromfähigkeit des Frequenzumrichters 100.000 Arms.
Empfohlene maximale Sicherung
AF-600 1-Phasenlei
stung
AF-600 3-Phasenlei
stungBussmann Bussmann Bussmann Bussmann Bussmann Bussmann
[kW] [kW] Typ RK1 1) Typ J Typ T Typ CC Typ CC Typ CC
0,75 KTN-R-10 JKS-10 JJN-10 FNQ-R-10 KTK-R-10 LP-CC-10
1,5 KTN-R-15 JKS-15 JJN-15 FNQ-R-15 KTK-R-15 LP-CC-15
1,5 2,2 KTN-R-20 JKS-20 JJN-20 FNQ-R-20 KTK-R-20 LP-CC-20
2,2 3,7 KTN-R-30 JKS-30 JJN-30 FNQ-R-30 KTK-R-30 LP-CC-30
3,7 5,5-7,5 KTN-R-50 KS-50 JJN-50 - - -
5,5 11 KTN-R-60 JKS-60 JJN-60 - - -
7,5 15 KTN-R-80 JKS-80 JJN-80 - - -
18,5-22 KTN-R-125 JKS-125 JJN-125 - - -
15 30 KTN-R-150 JKS-150 JJN-150 - - -
23 37 KTN-R-200 JKS-200 JJN-200 - - -
45 KTN-R-250 JKS-250 JJN-250 - - -
Tabelle 8.8 200-240V
Empfohlene maximale Sicherung
AF-600 1-
Phasenleistung
AF-600 3-
Phasenleistung
SIBA LittelfuseFerraz-
ShawmutFerraz-
Shawmut
[kW] [kW] Typ RK1 Typ RK1 Typ CC Typ RK13)
0,75 5017906-010 KLN-R-10 ATM-R-10 A2K-10-R
1,5 5017906-016 KLN-R-15 ATM-R-15 A2K-15-R
1,5 2,2 5017906-020 KLN-R-20 ATM-R-20 A2K-20-R
2,2 3,7 5012406-032 KLN-R-30 ATM-R-30 A2K-30-R
3,7 5,5-7,5 5014006-050 KLN-R-50 - A2K-50-R
5,5 11 5014006-063 KLN-R-60 - A2K-60-R
7,5 15 5014006-080 KLN-R-80 - A2K-80-R
18,5-22 2028220-125 KLN-R-125 - A2K-125-R
15 30 2028220-150 KLN-R-150 - A2K-150-R
23 37 2028220-200 KLN-R-200 - A2K-200-R
45 2028220-250 KLN-R-250 - A2K-250-R
Tabelle 8.9 200-240V
Technische Daten AF-600 FP-Kurzanleitung
44 DET-759A/D
88
Empfohlene maximale Sicherung
AF-600 1-phasig
AF-600 3-phasig
Bussmann LittelfuseFerraz-
ShawmutFerraz-
Shawmut
[kW] [kW] Typ JFHR22) Typ JFHR2 Typ JFHR24) Typ J
0,75 FWX-10 - - HSJ-10
1,5 FWX-15 - - HSJ-15
1,5 2,2 FWX-20 - - HSJ-20
2,2 3,7 FWX-30 - - HSJ-30
3,7 5,5-7,5 FWX-50 - - HSJ-50
5,5 11 FWX-60 - - HSJ-60
7,5 15 FWX-80 - - HSJ-80
18,5-22 FWX-125 - - HSJ-125
15 30 FWX-150 L25S-150 A25X-150 HSJ-150
23 37 FWX-200 L25S-200 A25X-200 HSJ-200
45 FWX-250 L25S-250 A25X-250 HSJ-250
Tabelle 8.10 200-240V
1) KTS-Sicherungen von Bussmann können KTN bei 240-V-Frequenzumrichtern ersetzen.
2) FWH-Sicherungen von Bussmann können FWX bei 240-V-Frequenzumrichtern ersetzen.
3) A6KR-Sicherungen von FERRAZ SHAWMUT können A2KR bei 240-V-Frequenzumrichtern ersetzen.
4) A50X-Sicherungen von FERRAZ SHAWMUT können A25X bei 240-V-Frequenzumrichtern ersetzen.
Empfohlene maximale Sicherung
AF-6001-phasig
AF-6003-phasig
Bussmann Bussmann Bussmann Bussmann Bussmann Bussmann
[kW] [kW] Typ RK1 Typ J Typ T Typ CC Typ CC Typ CC
0,75 KTS-R-6 JKS-6 JJS-6 FNQ-R-6 KTK-R-6 LP-CC-6
1,5-2,2 KTS-R-10 JKS-10 JJS-10 FNQ-R-10 KTK-R-10 LP-CC-10
3,7 KTS-R-20 JKS-20 JJS-20 FNQ-R-20 KTK-R-20 LP-CC-20
5,5 KTS-R-25 JKS-25 JJS-25 FNQ-R-25 KTK-R-25 LP-CC-25
7,5 KTS-R-30 JKS-30 JJS-30 FNQ-R-30 KTK-R-30 LP-CC-30
11-15 KTS-R-40 JKS-40 JJS-40 - - -
18,5 KTS-R-50 JKS-50 JJS-50 - - -
7,5 22 KTS-R-60 JKS-60 JJS-60 - - -
11 30 KTS-R-80 JKS-80 JJS-80 - - -
3 KTS-R-100 JKS-100 JJS-100 - - -
45 KTS-R-125 JKS-125 JJS-125 - - -
18,5 55 KTS-R-150 JKS-150 JJS-150 - - -
37 75 KTS-R-200 JKS-200 JJS-200 - - -
90 KTS-R-250 JKS-250 JJS-250 - - -
Tabelle 8.11 380-480 V, 125 HP und darunter
Technische Daten AF-600 FP-Kurzanleitung
DET-759A/D 45
8 8
Empfohlene maximale Sicherung
AF-600 1-phasig
AF-600 3-phasig
SIBA LittelfuseFerraz-
ShawmutFerraz-
Shawmut
[kW] [kW] Typ RK1 Typ RK1 Typ CC Typ RK1
0,75 5017906-006 KLS-R-6 ATM-R-6 A6K-10-6
1,5-2,2 5017906-010 KLS-R-10 ATM-R-10 A6K-10-R
3,7 5017906-020 KLS-R-20 ATM-R-20 A6K-20-R
5,5 5017906-025 KLS-R-25 ATM-R-25 A6K-25-R
7,5 5012406-032 KLS-R-30 ATM-R-30 A6K-30-R
11-15 5014006-040 KLS-R-40 - A6K-40-R
18,5 5014006-050 KLS-R-50 - A6K-50-R
7,5 22 5014006-063 KLS-R-60 - A6K-60-R
11 30 2028220-100 KLS-R-80 - A6K-80-R
37 2028220-125 KLS-R-100 - A6K-100-R
45 2028220-125 KLS-R-125 - A6K-125-R
18,5 55 2028220-160 KLS-R-150 - A6K-150-R
37 75 2028220-200 KLS-R-200 - A6K-200-R
90 2028220-250 KLS-R-250 - A6K-250-R
Tabelle 8.12 380-480 V, 125 HP und darunter
Empfohlene maximale Sicherung
AF-600 1-phasigAF-600 3-
phasigBussmann Ferraz-Shawmut Ferraz-Shawmut Littelfuse
[kW] [kW] Typ JFHR2 Typ J Typ JFHR21) Typ JFHR2
0,75 FWH-6 HSJ-6 - -
1,5-2,2 FWH-10 HSJ-10 - -
3,7 FWH-20 HSJ-20 - -
5,5 FWH-25 HSJ-25 - -
7,5 FWH-30 HSJ-30 - -
11-15 FWH-40 HSJ-40 - -
18,5 FWH-50 HSJ-50 - -
7,5 22 FWH-60 HSJ-60 - -
11 30 FWH-80 HSJ-80 - -
37 FWH-100 HSJ-100 - -
45 FWH-125 HSJ-125 - -
18,5 55 FWH-150 HSJ-150 - -
37 75 FWH-200 HSJ-200 A50-P-225 L50-S-225
90 FWH-250 HSJ-250 A50-P-250 L50-S-250
Tabelle 8.13 380-480 V, 125 HP und darunter
1) A50QS-Sicherungen von Ferraz-Shawmut können A50P-Sicherungen ersetzen.
Technische Daten AF-600 FP-Kurzanleitung
46 DET-759A/D
88
Empfohlene maximale Sicherung
AF-600 Bussmann Bussmann Bussmann Bussmann Bussmann Bussmann
[kW] Typ RK1 Typ J Typ T Typ CC Typ CC Typ CC
0,75 KTS-R-5 JKS-5 JJS-6 FNQ-R-5 KTK-R-5 LP-CC-5
1,5-2,2 KTS-R-10 JKS-10 JJS-10 FNQ-R-10 KTK-R-10 LP-CC-10
3,7 KTS-R20 JKS-20 JJS-20 FNQ-R-20 KTK-R-20 LP-CC-20
5,5 KTS-R-25 JKS-25 JJS-25 FNQ-R-25 KTK-R-25 LP-CC-25
7,5 KTS-R-30 JKS-30 JJS-30 FNQ-R-30 KTK-R-30 LP-CC-30
11-15 KTS-R-35 JKS-35 JJS-35 - - -
18,5 KTS-R-45 JKS-45 JJS-45 - - -
22 KTS-R-50 JKS-50 JJS-50 - - -
30 KTS-R-60 JKS-60 JJS-60 - - -
37 KTS-R-80 JKS-80 JJS-80 - - -
45 KTS-R-100 JKS-100 JJS-100 - - -
55 KTS-R-125 JKS-125 JJS-125 - - -
75 KTS-R-150 JKS-150 JJS-150 - - -
90 KTS-R-175 JKS-175 JJS-175 - - -
Tabelle 8.14 525-600 V, 125 HP und darunter
Empfohlene maximale Sicherung
AF-600 SIBA LittelfuseFerraz-
ShawmutFerraz-
Shawmut
[kW] Typ RK1 Typ RK1 Typ RK1 Typ J
0,75 5017906-005 KLS-R-005 A6K-5-R HSJ-6
1,5-2,2 5017906-010 KLS-R-010 A6K-10-R HSJ-10
3,7 5017906-020 KLS-R-020 A6K-20-R HSJ-20
5,5 5017906-025 KLS-R-025 A6K-25-R HSJ-25
7,5 5017906-030 KLS-R-030 A6K-30-R HSJ-30
11-15 5014006-040 KLS-R-035 A6K-35-R HSJ-35
18,5 5014006-050 KLS-R-045 A6K-45-R HSJ-45
22 5014006-050 KLS-R-050 A6K-50-R HSJ-50
30 5014006-063 KLS-R-060 A6K-60-R HSJ-60
37 5014006-080 KLS-R-075 A6K-80-R HSJ-80
45 5014006-100 KLS-R-100 A6K-100-R HSJ-100
55 2028220-125 KLS-R-125 A6K-125-R HSJ-125
75 2028220-150 KLS-R-150 A6K-150-R HSJ-150
90 2028220-200 KLS-R-175 A6K-175-R HSJ-175
Tabelle 8.15 525-600 V, 125 HP und darunter
1) Die dargestellten 170M-Sicherungen von Bussmann verwenden den optischen -/80-Kennmelder. Die Kennmel-dersicherungen –TN/80 Typ T, -/110 oder TN/110 Typ T derselben Größe und Stromstärke können ersetzt werden.
Technische Daten AF-600 FP-Kurzanleitung
DET-759A/D 47
8 8
AF-600 3-phasig Bussmann Bussmann Bussmann SIBA Littelfuse Ferraz-Shawmut Ferraz-Shawmut
[kW] Typ RK1 Typ J Typ T Typ RK1 Typ RK1 Typ RK1 Typ J
11 KTS-R-30 JKS-30 JJS-30 5017906-030 KLS-R-030 A6K-30R HST-30
15 KTS-R-35 JKS-35 JJS-35 5014006-040 KLS-R-035 A6K-35R HST-35
18,5 KTS-R-45 JKS-45 JJS-45 5014006-050 KLS-R-045 A6K-45R HST-45
22 KTS-R50 JKS-50 JJS-50 5014006-050 KLS-R-50 A6K-50R HST-50
30 KTS-R-60 JKS-60 JJS-60 5014006-063 KLS-R-060 A6K-60R HST-60
37 KTS-R-80 JKS-80 JJS-80 5014006-080 KLS-R-075 A6K-80R HST-80
45 KTS-R-100 JKS-100 JJS-100 5014006-100 KLS-R-100 A6K-100R HST-100
55 KTS-R125 JKS-125 JJS-125 2028220-125 KLS-125 A6K-125R HST-125
75 KTS-R150 JKS-150 JJS-150 2028220-150 KLS-150 A6K-150R HST-150
90 KTS-R175 JKS-175 JJS-175 2028220-200 KLS-175 A6K-175R HST-175
Tabelle 8.16 525-690, IP21/NEMA 1 und IP55/NEMA 12
Technische Daten AF-600 FP-Kurzanleitung
48 DET-759A/D
88
Empfohlene maximale Sicherung
AF-600Bussmann
Teilenummer
Alternativextern
BussmannTeilenummer
Alternativ externBussmann
Teilenummer
Alternativ externSiba
Teilenummer
Alternativ externLittelfuse
Teilenummer
AlternativexternFerraz-
ShawmutTeilenummer
Alternativ externFerraz-Shawmut
Teilenummer
[kW] Typ JFHR2 Typ JFHR2 Typ T/JDDZ Typ JFHR2 Typ JFHR2 Typ JFHR2
110 170M3017 FWH-300 JJS-300 2028220-315 L50-S-300 A50-P-300
132 170M3018 FWH-350 JJS-350 2028220-315 L50-S-350 A50-P-350
160 170M4012 FWH-400 JJS-400 206xx32-400 L50-S-400 A50-P-400
200 170M4014 FWH-500 JJS-500 206xx32-500 L50-S-500 A50-P-500
250 170M4016 FWH-600 JJS-600 206xx32-600 L50-S-600 A50-P-600
315 170M4017 20 610 32.700 6.9URD31D08A0700
355 170M6013 22 610 32.900 6.9URD33D08A0900
400 170M6013 22 610 32.900 6.9URD33D08A0900
450 170M6013 22 610 32.900 6.9URD33D08A0900
500 170M7081
560 170M7081
630 170M7082
710 170M7082
800 170M7083
1000 170M7083
Tabelle 8.17 380-480 V, über 125 HP
AF-600 Bussmann Teilenummer Nennwert AC Siba Teilenummer
[kW]
500 170M8611 1100 A, 1000 V 20 781 32.1000
560 170M8611 1100 A, 1000 V 20 781 32.1000
630 170M6467 1400 A, 700 V 20 681 32.1400
710 170M6467 1400 A, 700 V 20 681 32.1400
800 170M8611 1100 A, 1000 V 20 781 32.1000
1000 170M6467 1400 A, 700 V 20 681 32.1400
Tabelle 8.18 380-480 V, Baugröße 6, Wechselrichtermodul DC-Zwischenkreissicherungen
Technische Daten AF-600 FP-Kurzanleitung
DET-759A/D 49
8 8
AF-600Bussmann Teilenummer Alternativ extern
Siba TeilenummerAlternativ extern
Ferraz-Shawmut Teilenummer
[kW] Typ JFHR2 Typ JFHR2
132 170M3017 2061032,315 6.9URD30D08A0315
160 170M3018 2061032,35 6.9URD30D08A0350
200 170M4011 2061032,35 6.9URD30D08A0350
250 170M4012 2061032,4 6.9URD30D08A0400
315 170M4014 2061032,5 6.9URD30D08A0500
400 170M5011 2062032,55 6.9URD32D08A0550
450 170M4017
500 170M4017 20 610 32.700 6.9URD31D08A0700
560 170M6013 20 610 32.700 6.9URD31D08A0700
630 170M6013 22 610 32.900 6.9URD33D08A0900
710 170M7081 22 610 32.900 6.9URD33D08A0900
800 170M7081
900 170M7081
1000 170M7081
1200 170M7082
1400 170M7083
Tabelle 8.19 525-690 V, über 125 HP
AF-600 Bussmann Teilenummer Nennwert AC Siba Teilenummer
[kW]
710 170M8611 1100 A, 1000 V 20 781 32.1000
800 170M8611 1100 A, 1000 V 20 781 32.1000
900 170M8611 1100 A, 1000 V 20 781 32.1000
1000 170M8611 1100 A, 1000 V 20 781 32.1000
1200 170M8611 1100 A, 1000 V 20 781 32.1000
1400 170M8611 1100 A, 1000 V 20 781 32.1000
Tabelle 8.20 525-690 V, Baugröße 6, Wechselrichtermodul DC-Zwischenkreissicherungen
* Die dargestellten 170M-Sicherungen von Bussmann verwenden den optischen -/80-Kennmelder. Die Kennmeldersicherungen -TN/80 Typ T, -/110oder TN/110 Typ T derselben Größe und Stromstärke können für den externen Gebrauch ausgetauscht werden.
** Zur Erfüllung der UL-Anforderungen kann jede UL-gelistete Sicherung mit mindestens 500 V und dazugehörigem Nennstrom verwendet werden.
Technische Daten AF-600 FP-Kurzanleitung
50 DET-759A/D
88
9 Klemme und zugehöriger Draht
9.1 Kabel
Leis
tung
[kW
]G
ehäu
se
Net
zM
otor
Zwis
chen
krei
skop
plun
gBr
emse
Mas
se*
200-
240V
380-
480V
525-
600V
525-
690V
A
nzug
sd-
rehm
ome
nte
[Nm
]
Leite
rque
r-sc
hnitt
[mm
2]
Anz
ugsd
-re
hmom
ente
[Nm
]
Leite
rque
r-sc
hnitt
[mm
2]
Anz
ugsd
-re
hmom
ent
e [N
m]
Leite
rque
r-sc
hnitt
[mm
2]
Anz
ugsd
-re
hmom
ent
e [N
m]
Leite
rque
r-sc
hnitt
[mm
2]
Anz
ugsd
-re
hmom
ent
e [N
m]
0,75
-2,2
kW0,
75-3
,7 k
W
IP
20
1,8
4 (1
0)
1,8
4 (1
0)1,
84
(10)
1,8
4 (1
0)
3 /
27
3,7
kW5,
5-7,
5 kW
0,75
-7,5
kW
IP20
0,75
-3,7
kW0,
75-7
,5 k
W0,
75-7
,5kW
IP
55od
erIP
665,
5-11
kW
11-1
8,5
kW11
-18,
5 kW
IP
20
16 (6
)16
(6)
16 (6
)16
(6)
5,5-
11 k
W11
-18,
5 kW
11-1
8,5
kW
IP55
oder
IP66
1,5
1,5
15-1
8,5
kW22
-37
kW22
-37
kW
IP20
4,5
35 (2
)4,
535
(2)
4,5
35 (2
)
4,5
35 (2
)15
kW
22-3
0 kW
22-3
0 kW
11-3
0 kW
IP55
oder
IP66
3,7
3,7
22-3
0 kW
45-5
5 kW
45-5
5 kW
IP
20
10 /
89
50 (1
)
10 /
89
50 (1
)
10 /
89
50 (1
)
10 /
89
50 (1
)
18,5
-30
kW37
-55
kW37
-55
kW
IP55
oder
IP66
90 (3
/0)
90 (3
/0)
90 (3
/0)
90 (3
/0)
37-4
5 kW
75-9
0 kW
75-9
0 kW
IP
20
14 /
124
150
(300
MCM
)14
/ 1
24
150
(300
MCM
)14
/ 1
24
95 (4
/0)
14 /
124
95 (4
/0)
37-4
5 kW
75-9
0 kW
75-9
0 kW
37-9
0 kW
IP55
oder
IP66
120
(4/0
)12
0 (4
/0)
120
(4/0
)12
0 (4
/0)
11
0-13
2 kW
11
0-16
0 kW
alle
19 /
168
2x70
(2x2
/0)
19 /
168
2x70
(2x2
/0)
9,5
2x70
(2x2
/0)
9,5
2x70
(2x2
/0)
19 /
168
16
0-25
0 kW
20
0-40
0 kW
alle
2x18
5(2
x350
MCM
)
2x18
5 (2
x350
MCM
)2x
185
(2x3
50 M
CM)
2x18
5 (2
x350
MCM
)
315-
450
kW
450-
630
kWal
le4x
240
(4x5
00M
CM)
4x24
0 (4
x500
MCM
)
19 /
168
4x24
0(4
x500
MCM
)
50
0-71
0 kW
71
0-90
0 kW
alle
8x24
0(8
x500
MCM
)
8x15
0 (8
x300
MCM
)4x
120
(4x2
50 M
CM)
4x18
5 (4
x350
MCM
)
80
0-10
00 k
W
1000
-140
0 kW
alle
12x1
50(1
2x30
0M
CM)
6x18
5 (6
x350
MCM
)
* M
axim
aler
Kab
elqu
ersc
hnitt
nac
h n
atio
nale
r Vo
rsch
rift
Klemme und zugehöriger Drah... AF-600 FP-Kurzanleitung
DET-759A/D 51
9 9
1 Sécurité
AVERTISSEMENTHAUTE TENSION !Les variateurs de fréquence contiennent des tensionsélevées lorsqu'ils sont reliés à l'alimentation secteur CA.L'installation, le démarrage et la maintenance doivent êtreeffectués uniquement par du personnel qualifié. Le non-respect de cette instruction peut entraîner la mort ou desblessures graves.
Haute tensionLes variateurs de fréquence sont raccordés à des tensionssecteur dangereuses. Des précautions rigoureuses doiventêtre prises pour se protéger contre les chocs. Seul dupersonnel formé, connaissant les équipements électro-niques, doit installer, démarrer et entretenir ce matériel.
AVERTISSEMENTDÉMARRAGE IMPRÉVU !Lorsque le variateur est connecté à l'alimentation secteurCA, le moteur peut démarrer à tout moment. Le variateur,le moteur et tout équipement entraîné doivent être prêts àfonctionner. S'ils ne sont pas prêts à fonctionner alors quele variateur est relié au secteur CA, cela peut entraîner lamort, des blessures graves ou des dégâts matériels.
Démarrage imprévuLorsque le variateur est connecté à l'alimentation secteurCA, le moteur peut être démarré par un commutateurexterne, un ordre du bus série, un signal de référenced'entrée ou du fait d'une condition de panne supprimée.Prendre les précautions appropriées pour éviter toutdémarrage imprévu.
AVERTISSEMENTTEMPS DE DÉCHARGE !Les variateurs de fréquence contiennent des condensateursdans le circuit intermédiaire qui peuvent rester chargésmême lorsque l'alimentation CA est déconnectée. Pouréviter les dangers liés à l'électricité, couper l'alimentationCA du variateur avant d'entreprendre tout entretien ouréparation et attendre pendant le temps spécifié dans lepar. Tableau 1.1. Le non-respect du temps d'attente spécifiéaprès la mise hors tension avant tout entretien ouréparation peut entraîner le décès ou des blessures graves.
Tension PuissanceTemps d'attenteminimum
200-240 V0,75-3,7 kW 1-5 HP 4 minutes
5,5-45 kW 7,5-60 HP 15 minutes
Tension PuissanceTemps d'attenteminimum
380-480 V
0,75-7,5 kW 1-10 HP 4 minutes
11-90 kW 15-125 HP 15 minutes
110-250 kW
150-350 HP20 minutes
315-1000 kW
450-1350 HP40 minutes
525-600 V
0,75-7,5 kW 1-10 HP 4 minutes
11-90 kW 15-125 HP 15 minutes
110-315 kW150-400 HP
20 minutes
355-1000 kW
450-1350 HP30 minutes
525-690 V
11-75 kW
15-125 HP15 minutes
110-400 kW150-550 HP
20 minutes
400-1400 kW600-1900 HP
30 minutes
SymbolesLes symboles suivants sont utilisés dans ce manuel.
Sécurité Guide rapide de l'AF-600 FP
DET-759A/F 1
1 1
AVERTISSEMENTIndique une situation potentiellement dangereuse qui, sielle n'est pas évitée, peut entraîner des blessures graves oule décès.
ATTENTIONIndique une situation potentiellement dangereuse qui, sielle n'est pas évitée, peut entraîner des blessures superfi-cielles à modérées. Ce signe peut aussi être utilisé pourmettre en garde contre des pratiques non sûres.
ATTENTIONIndique une situation qui peut entraîner des dégâtsmatériels.
REMARQUE!Met en évidence une information qui doit être attenti-vement prise en considération pour éviter toute erreur outoute utilisation non optimale de l'équipement.
Homologations
Sécurité Guide rapide de l'AF-600 FP
2 DET-759A/F
11
2 Introduction
Illustration 2.1 Éclaté de l'unité de taille 1X
1 Clavier 10 Bornes de sortie du moteur 96 (U), 97 (V), 98 (W)
2 Connecteur du bus série RS-485 (+68, -69) 11 Relais 1 (01, 02, 03)
3 Connecteur d'E/S analogiques 12 Relais 2 (04, 05, 06)
4 Fiche d'entrée du Clavier 13 Bornes de freinage (-81, +82) et de répartition de la charge (-88,
+89)
5 Commutateurs analogiques (A53), (A54) 14 Bornes d'entrée d'alimentation secteur 91 (L1), 92 (L2), 93 (L3)
6 Serre-câble/terre de protection (PE) 15 Connecteur USB
7 Plaque de connexion à la terre 16 Commutateur de la borne du bus série
8 Bride de mise à la terre (PE) 17 E/S digitales et alimentation 24 V
9 Bride de mise à la terre et serre-câble pour câble blindé 18 Cache du câble de commande
REMARQUE!Se reporter au Manuel d'utilisation de l'AF-600 FP pour plus d'informations sur les autres tailles d'unité.
Introduction Guide rapide de l'AF-600 FP
DET-759A/F 3
2 2
3 Installation
3.1 Liste de vérification du site d'installation
• Le refroidissement du variateur repose sur lacirculation de l'air ambiant. Observer leslimitations concernant la température de l'airambiant pour un fonctionnement optimal.
• Vérifier que l'emplacement d'installation a unerésistance suffisante pour supporter le variateur.
• Préserver l'intérieur du variateur de toutepoussière ou saleté. Veiller à ce que lescomposants restent le plus propre possible. Dansles zones de construction, prévoir une enveloppede protection. Les protections IP54 (NEMA 12)optionnelles peuvent être nécessaires.
• Garder le manuel, les dessins et les schémas àportée de main pour consulter les instructionsd'installation et de fonctionnement détaillées. Leprésent manuel doit rester à portée de main desopérateurs de l'équipement.
• Placer l'équipement aussi près que possible dumoteur. Maintenir les câbles du moteur aussicourts que possible. Vérifier les caractéristiquesdu moteur pour connaître les tolérances exactes.Ne pas dépasser
• 300 m (1000 pieds) pour les câbles dumoteur non blindés
• 150 m (500 pieds) pour les câblesblindés.
3.2 Liste de vérification de pré-installationdu moteur et du Variateur
• Comparer le numéro de modèle de l'unité sur laplaque signalétique à celle qui a été commandéepour s'assurer qu'il s'agit du bon équipement.
• Vérifier que les éléments suivants sontdimensionnés pour la même tension :
Secteur (alimentation)
Variateur
Moteur
• Veiller à ce que le courant nominal de sortie duvariateur soit supérieur ou égal au courant depleine charge du moteur pour une performanceoptimale de ce dernier.
La taille du moteur et la puissance duvariateur doivent correspondre pour une
protection contre les surchargesadaptée.
Si les caractéristiques nominales duvariateur sont inférieures à celles dumoteur, la puissance maximale dumoteur ne peut être atteinte.
3.3 Installation mécanique
3.3.1 Refroidissement
• Pour créer une circulation d'air de refroidis-sement, monter l'unité sur une surface planesolide ou sur la plaque arrière optionnelle.
• Un dégagement en haut et en bas doit êtreprévu pour le refroidissement. Généralement, undégagement de 100-225 mm (4-10 pouces) estnécessaire.
• Le montage incorrect peut entraîner unesurchauffe et une performance réduite.
• Le déclassement doit être envisagé en cas detempératures entre 40 °C (104 °F) et 50 °C (122°F) et d'une altitude de 1000 m (3300 pieds) au-dessus du niveau de la mer. Consulter le Manuelde configuration pour des renseignementsdétaillés.
Illustration 3.1 Dégagement en haut et en bas pour le refroidis-sement
Installation Guide rapide de l'AF-600 FP
4 DET-759A/F
33
Tension Puissance Dégagement a/b
200-240 V
0,25-3,7 kW 1/3-5 HP 100 mm/4 in
5,5-30 kW 7,5-40 HP 200 mm/8 in
> 30 kW/40 HP 225 mm/10 in
380-480 V
0,37-7,5 kW 1/2-10 HP 100 mm/4 in
11-55 kW 15-75 HP 200 mm/8 in
> 55 kW/75 HP 225 mm/10 in
525-600 V
0,37-7,5 kW 1/2-10 HP 100 mm/4 in
11-55 kW 15-75 HP 200 mm/8 in
> 55 kW/75 HP 225 mm/10 in
525-690 V toutes 225 mm/10 in
Tableau 3.1 Exigences de dégagement minimum pour la circulation d'air
3.3.2 Levage
• Vérifier le poids de l'unité pour déterminer laméthode de levage la plus sûre.
• S'assurer que le dispositif de levage est adapté àla tâche à réaliser.
• Si nécessaire, prévoir un élévateur, une grue ouun chariot élévateur à fourche présentant lescaractéristiques qui conviennent au déplacementde l'unité.
• Pour le levage, utiliser les anneaux de levage surl'unité le cas échéant.
3.3.3 Installation
• Monter l'unité à la verticale.
• Le variateur permet l'installation côte à côte.
• Veiller à ce que l'emplacement d'installation soitsuffisamment résistant pour supporter le poids del'unité.
• Monter l'unité sur une surface plane solide ou surla plaque arrière optionnelle pour permettre unecirculation d'air de refroidissement (voirl'Illustration 3.2 et l'Illustration 3.3).
• Le montage incorrect peut entraîner unesurchauffe et une performance réduite.
• Utiliser les trous de montage ovalisés (si présents)sur l'unité pour le montage mural.
Illustration 3.2 Installation correcte sur plaque arrière
L'élément A est une plaque arrière correctement installéepour que la circulation d'air nécessaire refroidisse l'unité.
Illustration 3.3 Installation correcte sur rails
REMARQUE!La plaque arrière est nécessaire pour le montage sur rails.
Installation Guide rapide de l'AF-600 FP
DET-759A/F 5
3 3
3.4 Installation électrique
Cette section contient des instructions détaillées pour le câblage du variateur. Les tâches suivantes sont décrites.
• Câblage du moteur aux bornes de sortie du variateur
• Câblage du secteur CA aux bornes d'entrée du variateur
• Raccordement du câblage de commande et de la communication série
• Une fois que la tension a été appliquée, vérification de la puissance d'entrée et de la puissance du moteur ;programmation des bornes de commande selon leurs fonctions prévues
L'Illustration 3.4 montre un raccordement électrique de base.
Illustration 3.4 Dessin schématique des câblages de base.
Installation Guide rapide de l'AF-600 FP
6 DET-759A/F
33
3.4.1 Exigences
AVERTISSEMENTDANGERS LIÉS À L'ÉQUIPEMENT !Les arbres tournants et les équipements électriquespeuvent être dangereux. Tous les travaux électriquesdoivent être conformes aux réglementations électriqueslocales et nationales. L'installation, le démarrage et lamaintenance doivent être effectués uniquement par dupersonnel formé et qualifié. Le non-respect de cesconsignes est susceptible d'entraîner la mort ou desblessures graves.
ATTENTIONISOLATION DU CÂBLAGE !Acheminer les câbles d'alimentation, du moteur et decommande dans trois conduits métalliques ou utiliser uncâble blindé pour une bonne isolation du bruit hautefréquence. Toute mauvaise isolation des câblages del'alimentation, du moteur et de commande risque deprovoquer une baisse de la performance du variateur et del'équipement correspondant par rapport aux conditionsoptimales.
Pour des raisons de sécurité, respecter les aspectssuivants :
• L'équipement de commandes électroniques estraccordé à des tensions secteur dangereuses. Desprécautions rigoureuses doivent être prises pourse protéger contre les chocs électriques lors del'application de la tension à l'unité.
• Acheminer séparément les câbles moteurprovenant de plusieurs variateurs de fréquence.La tension induite des câbles moteur de sortieacheminés ensemble peut charger les conden-sateurs de l'équipement, même lorsquel'équipement est hors tension et verrouillé.
Protection de l'équipement et protection contre lessurcharges
• Une fonction activée électroniquement dans levariateur fournit une protection contre lessurcharges au moteur. La protection calcule leniveau d'augmentation pour activer la tempori-sation de la fonction de déclenchement (arrêt dela sortie du contrôleur). Plus le courant est élevé,plus la réponse d'arrêt est rapide. Cette fonctionoffre une protection du moteur de classe 20. Voirla section 7 Avertissements et alarmes pour desdétails sur la fonction de déclenchement.
• Comme le câblage du moteur envoie desimpulsions électriques haute fréquence, il estimportant d'acheminer séparément les câbles
d'alimentation secteur, de puissance du moteuret de commande. Utiliser un conduit métalliqueou un câble blindé séparé. Toute mauvaiseisolation des câblages de l'alimentation, dumoteur et de commande risque de provoquerune baisse de la performance de l'équipementpar rapport aux conditions optimales.
• Tous les variateurs de fréquence doivent êtrefournis avec une protection contre les court-circuits et les surcourants. Des fusibles d'entréesont nécessaires pour assurer cette protection,voir l'Illustration 3.5. Voir les calibres maximauxdes fusibles dans les sections 8.2.2 Conformité CEet 8.2.3 Tableaux de fusibles.
Illustration 3.5 Fusibles du Variateur
Caractéristiques et types de câbles
• L'ensemble du câblage doit être conforme auxréglementations nationales et locales en matièred'exigences de sections de câble et detempérature ambiante.
• GE recommande de choisir des raccords depuissance en cuivre prévus pour 75 °C minimum.
3.4.2 Exigences de mise à la terre
AVERTISSEMENTDANGERS LIÉS À LA MISE À LA TERRE !Pour la sécurité de l'opérateur, il est important de mettrele variateur à la terre correctement conformément auxréglementations électriques locales et nationales et auxinstructions contenues dans ce manuel. Les courants à laterre sont supérieurs à 3,5 mA. Le fait de ne pas mettre levariateur à la terre peut entraîner le décès ou des blessuresgraves.
Installation Guide rapide de l'AF-600 FP
DET-759A/F 7
3 3
REMARQUE!Il est de la responsabilité de l'utilisateur ou de l'installateurélectrique certifié de veiller à la mise à la terre correcte del'équipement selon les réglementations et les normesélectriques locales et nationales.
• Respecter toutes les réglementations locales etnationales pour une mise à la terre correcte del'équipement électrique.
• Une mise à la terre protectrice correcte de l'équi-pement avec des courants à la terre supérieurs à3,5 mA doit être prévue, voir Courant de fuite(> 3,5 mA).
• Un fil de terre dédié est nécessaire pour l'alimen-tation d'entrée, la puissance du moteur et lecâblage de commande.
• Utiliser les brides fournies avec l'équipement pourdes mises à la terre correctes.
• Ne pas relier un variateur à un autre variateur defréquence en "guirlande".
• Maintenir aussi courtes que possible les liaisonsde mise à la terre.
• Il est recommandé d'utiliser un câble à plusieursbrins pour réduire le bruit électrique.
• Respecter les exigences de câblage spécifiées parle fabricant du moteur.
3.4.2.1 Courant de fuite (> 3,5 mA)
Suivre les réglementations locales et nationales concernantla protection de mise à la terre de l'équipement en cas decourant de fuite > 3,5 mA.La technologie du Variateur implique une commutation defréquence élevée à des puissances importantes. Celagénère un courant de fuite dans la connexion à la terre.Un courant de défaut dans le variateur au niveau dubornier de puissance de sortie peut contenir unecomposante CC pouvant charger les condensateurs dufiltre et entraîner un courant à la terre transitoire. Lecourant de fuite à la terre dépend des différentes configu-rations du système dont le filtrage RFI, les câbles dumoteur blindés et la puissance du variateur.
La norme EN/CEI 61800-5-1 (norme produit concernant lessystèmes d'entraînement électriques) exige une attentionparticulière si le courant de fuite dépasse 3,5 mA. La miseà la terre doit être renforcée de l'une des façons suivantes :
• Fil de terre d'au moins 10 mm2
• Deux fils de terre séparés respectant lesconsignes de dimensionnement
Voir la norme EN 60364-5-54, paragraphe 543.7 pour plusd'informations.
Utilisation de RCDLorsque des relais de protection différentielle (RCD), aussiappelés disjoncteurs de mise à la terre (ELCB), sont utilisés,respecter les éléments suivants :
Utiliser les RCD de type B uniquement car ils sontcapables de détecter les courants CA et CC.
Utiliser des RCD avec un retard du courantd'appel pour éviter les pannes dues aux courantsà la terre transitoires.
Dimensionner les RCD selon la configuration dusystème et en tenant compte de l'environnementd'installation.
3.4.2.2 Mise à la terre à l'aide d'un câbleblindé
Les brides de mise à la terre sont fournies pour le câblagedu moteur (voir l'Illustration 3.6).
Illustration 3.6 Mise à la terre avec câble blindé
3.4.2.3 Mise à la terre à l'aide d'un conduit
ATTENTIONDANGERS LIÉS À LA MISE À LA TERRE !Ne pas utiliser le conduit raccordé au variateur pourremplacer une mise à la terre correcte. Les courants à laterre sont supérieurs à 3,5 mA. La mise à la terre incorrectepeut entraîner des blessures ou des courts-circuitsélectriques.
Des brides de mise à la terre dédiées sont fournies (voirl'Illustration 3.7).
Installation Guide rapide de l'AF-600 FP
8 DET-759A/F
33
Illustration 3.7 Mise à la terre avec conduit
Illustration 3.8 Câblage du moteur, du secteur et de la terrepour les châssis de taille 2X et au-delà l'aide d'un câble blindé
1. Utiliser une pince à dénuder pour retirerl'isolation pour une mise à la terre correcte.
2. Fixer la bride de mise à la terre à la portiondénudée du fil à l'aide des vis fournies.
3. Fixer le fil de terre à la bride de mise à la terrefournie.
3.4.3 Raccordement du moteur
AVERTISSEMENTTENSION INDUITE !Acheminer séparément les câbles du moteur de sortieprovenant de plusieurs variateurs de fréquence. La tensioninduite des câbles moteur de sortie acheminés ensemblepeut charger les condensateurs de l'équipement, mêmelorsque l'équipement est hors tension et verrouillé. Le faitde ne pas acheminer les câbles moteur de sortieséparément peut entraîner le décès ou des blessuresgraves.
• Respecter les réglementations locales etnationales pour les tailles de câbles, voir9.1.1 Câbles.
• Des caches amovibles pour câbles moteur ou despanneaux d'accès sont prévus en bas des unitésIP55/NEMA 12 et IP66/Nema 4X intérieur.
• Ne pas installer de condensateurs de correctiondu facteur de puissance entre le variateur et lemoteur.
• Ne pas câbler un dispositif d'amorçage ou à pôlescommutables entre le variateur et le moteur.
• Raccorder le câblage du moteur triphasé auxbornes 96 (U), 97 (V) et 98 (W).
• Relier le câble à la terre conformément auxinstructions de mise à la terre fournies.
• Respecter les exigences de câblage spécifiées parle fabricant du moteur.
Les trois illustrations suivantes représentent l'entréesecteur, le moteur et la mise à la terre des variateurs defréquence de base. Les configurations réelles peuventvarier selon les types d'unités et les équipementsoptionnels.
3.4.4 Raccordement au secteur CA
• Dimensionner les câbles selon le courant d'entréedu variateur.
• Respecter les réglementations locales etnationales pour les sections de câble, voir9.1.1 Câbles.
• Raccorder l'alimentation d'entrée CA triphaséeaux bornes L1, L2 et L3.
• L'alimentation doit être reliée aux bornes d'entréesecteur.
Installation Guide rapide de l'AF-600 FP
DET-759A/F 9
3 3
• Relier le câble à la terre conformément auxinstructions de mise à la terre fournies à lasection 3.4.2 Exigences de mise à la terre.
• Tous les variateurs de fréquence peuvent êtreutilisés avec une source d'entrée isolée mais aussiavec des lignes électriques reliées à la terre.Lorsque le variateur est alimenté par une sourceélectrique isolée de la terre (réseau IT ou triangleisolé de la terre) ou par un réseau TT/TNS avecmasse (triangle mis à la terre), régler le par.SP-50 Filtre RFI sur Inactif. Lorsqu'ils sont inactifs,les condensateurs internes du filtre RFI entre lechâssis et le circuit intermédiaire sont coupéspour éviter d'endommager le circuit intermédiaireet pour réduire les courants à effet de masseselon la norme CEI 61800-3.
3.4.5 Câblage de commande
• Isoler le câblage de commande à partir descomposants haute puissance du variateur.
• Si le variateur est raccordé à une thermistance,pour l'isolation PELV, le câblage de commande dela thermistance optionnelle doit être renforcé/doublement isolé. Une tension d'alimentation de24 V CC est recommandée.
3.4.5.1 Accès
• Retirer la plaque d'accès à l'aide d'un tournevis.Voir l'Illustration 3.9.
• Ou bien retirer le couvercle avant en desserrantles vis de fixation. Voir l'Illustration 3.10.Le couple de serrage du couvercle avant est de2,0 Nm pour l'unité de taille 15 et de 2,2 Nmpour les tailles 2X et 3X.
Illustration 3.9 Accès au câblage de commande pour protectionsIP20/châssis ouvert
Illustration 3.10 Accès au câblage de commande pourprotections IP55/Nema 12 et IP66/Nema 4/4X intérieur
3.4.5.2 Types de bornes de commande
L'Illustration 3.14 montre les connecteurs amovibles duvariateur. Les fonctions des bornes et leurs réglages pardéfaut sont résumés dans le Tableau 3.2.
Illustration 3.11 Emplacement des bornes de commande
Installation Guide rapide de l'AF-600 FP
10 DET-759A/F
33
• Le connecteur 1 comporte quatre bornesd'entrées digitales programmables, deux bornes(entrées ou sorties) digitales programmablessupplémentaires, une tension d'alimentation desbornes de 24 V CC et une borne commune pourla tension de 24 V CC fournie en option par leclient.
• Les bornes du connecteur 2 (+) 68 et (-) 69servent à la connexion de la communication sérieRS-485.
• Le connecteur 3 comporte deux entréesanalogiques, une sortie analogique, une tensiond'alimentation de 10 V CC et des bornescommunes pour les entrées et la sortie.
• Le connecteur 4 est un port USB disponible àutiliser avec le DCT-10.
• Deux sorties relais en forme de C sont aussifournies et se trouvent à différents emplacementsen fonction de la configuration du variateur et desa taille.
• Certaines options, disponibles pour êtrecommandées avec l'unité, prévoient des bornessupplémentaires. Voir le manuel fourni avecl'équipement optionnel.
Voir 8.1 Caractéristiques techniques pour avoir desprécisions sur les valeurs nominales des bornes.
Description des bornesEntrées/sorties digitales
Borne ParamètreRéglage
par défaut Description12, 13 - +24 V CC Tension d'alimentation
24 V CC. Le courantmaximum de sortieest de 200 mA au
total pour toutes lescharges de 24 V.Utilisable pour les
entrées digitales et lestransformateursexternes.
18 E-01 [8] Démarrage
Entrées digitales.19 E-02 [0] Inactif
32 E-05 [0] Inactif
33 E-06 [0] Inactif
27 E-03 [0] Inactif Peut être sélectionné
pour une entrée ouune sortie digitale. Leréglage par défaut est
Entrée.
29 E-04 [14] Jogging
20 - Commune aux entréesdigitales et potentielde 0 V pour l'alimen-tation 24 V.
Description des bornesEntrées/sorties digitales
Borne ParamètreRéglage
par défaut DescriptionEntrées/sorties analogiques
39 -
Commune à la sortieanalogique
42 AN-50 Vit. 0 - limitesupér.
Sortie analogiqueprogrammable. Lesignal analogique estde 0-20 mA ou 4-20mA à un maximum de
500 Ω50 - +10 V CC Tension d'alimentation
analogique de 10 VCC. Un maximum de15 mA est généra-lement utilisé pour unpotentiomètre ou unethermistance.
53 AN-1# Référence Entrée analogique.Peut être sélectionnéepour la tension ou lecourant. SélectionnermA ou V pour lescommutateurs A53 etA54.
54 AN-2# Retour
55 -
Commune aux entréesanalogiques.
Communication série
61 -
Filtre RC intégré pour
le blindage des câbles.UNIQUEMENT pour laconnexion du
blindage en cas deproblèmes CEM.
68 (+) O-3# Interface RS-485. Uncommutateur de cartede commande estfourni pour larésistance de laterminaison.
69 (-) O-3#
Relais
01, 02, 03 E-24 [0] [0] Alarme Sortie relais en formede C. Utilisable pourune tension CA ou CCet des chargesrésistives ouinductives.
04, 05, 06 E-24 [1] [0] Fonctionne
Tableau 3.2 Description des bornes
Installation Guide rapide de l'AF-600 FP
DET-759A/F 11
3 3
3.4.5.3 Câblage vers les bornes decommande
Les connecteurs des bornes de commande peuvent êtredébranchés du variateur pour faciliter l'installation, commeindiqué sur l'Illustration 3.12.
Illustration 3.12 Bornes de commande débranchées
1. Ouvrir le contact en insérant un petit tournevisdans la fente au-dessus ou au-dessous ducontact, comme indiqué sur l'Illustration 3.13.
2. Insérer un fil de commande dénudé dans lecontact.
3. Retirer le tournevis pour fixer le fil de commandedans le contact.
4. S'assurer que le contact est bien établi et n'estpas desserré. Un câblage de commande mal serrépeut être source de pannes ou d'un fonction-nement non optimal.
Illustration 3.13 Raccordement du câblage de commande
3.4.5.4 Utilisation de câbles de commandeblindés
Blindage correctLa méthode privilégiée dans la plupart des cas est de fixerles câbles de commande et de communication série avecdes étriers de blindage à chaque extrémité pour garantir lemeilleur contact de câble haute fréquence possible.
Boucles de mise à la terre de 50/60 HzEn présence de câbles de commande très longs, desboucles de mise à la terre peuvent survenir. Pour remédierà ce problème, relier l'une des extrémités du blindage à laterre via un condensateur 100 nF (fils courts).
Éviter le bruit CEM sur la communication sériePour éliminer le bruit basse fréquence entre les variateursde fréquence, relier l'une des extrémités du blindage à laborne 61. Cette borne est reliée à la terre via une liaisonRC interne. Utiliser une paire torsadée afin de réduirel'interférence entre les conducteurs.
3.4.5.5 Fonctions des bornes de commande
Les fonctions du Variateur sont commandées par laréception de signaux d'entrée de commande.
• Chaque borne doit être programmée pour lafonction qu'elle doit prendre en charge dans lesparamètres associés à cette borne. Voir leTableau 3.2 sur les bornes et leurs paramètresconnexes.
• Il est important de confirmer que la borne decommande est programmée pour la fonctioncorrecte.
• La programmation des bornes par défaut sert àlancer le fonctionnement du variateur sur unmode d'exploitation typique.
Installation Guide rapide de l'AF-600 FP
12 DET-759A/F
33
3.4.5.6 Commutateurs des bornes 53 et 54
• Les bornes d'entrées analogiques 53 et 54permettent de choisir des signaux d'entrée detension (0 à 10 V) ou de courant (0/4-20 mA).
• Couper l'alimentation du variateur avant dechanger la position des commutateurs.
• Régler les commutateurs A53 et A54 poursélectionner le type de signal. U sélectionne latension, I sélectionne le courant.
• Les commutateurs sont accessibles lorsque leclavier a été retiré (voir l'Illustration 3.14). Noterque certaines cartes d'option disponibles pourl'unité peuvent cacher ces commutateurs. Ellesdoivent donc être retirées pour modifier lesréglages des commutateurs. Toujours mettrel'unité hors tension avant de démonter les cartesd'option.
• La valeur par défaut de la borne 53 concerne lesignal de référence de vitesse en boucle ouverteréglé dans le par. DR-61 Régl.commut.born.53.
• La valeur par défaut de la borne 54 concerne lesignal de retour en boucle fermée réglé dans lepar. DR-63 Régl.commut.born.54.
130BT310.10
Illustration 3.14 Emplacement des commutateurs des bornes 53
et 54
3.4.6 Communication série
Le est une interface de bus à deux fils compatible avecune topologie de réseau multipoints, c.-à-d. que desnœuds peuvent être connectés comme un bus ou via descâbles de dérivation depuis un tronçon de ligne commun.Un total de 32 nœuds peut être connecté à un segmentde réseau.
Les répéteurs divisent les segments de réseaux. Noter quechaque répéteur fonctionne comme un nœud au sein dusegment sur lequel il est installé. Chaque nœud connectéau sein d'un réseau donné doit disposer d'une adresse denœud unique pour tous les segments.Terminer chaque segment aux deux extrémités, à l'aidesoit du commutateur de terminaison (S801) du variateur defréquence soit d'un réseau de résistances de terminaisonpolarisé. Utiliser toujours un câble blindé à paire torsadée(STP) pour le câblage du bus et suivre toujours les règleshabituelles en matière d'installation.Il est important de disposer d'une mise à la terre de faibleimpédance du blindage à chaque nœud, y compris àhautes fréquences. Pour cela, il convient de relier unegrande surface du blindage à la terre, par exemple à l'aided'un étrier de serrage ou d'un presse-étoupe conducteur. Ilpeut être nécessaire d'appliquer des câbles d'égalisation depotentiel pour maintenir le même potentiel de terre danstout le réseau, en particulier sur les installationscomportant des câbles longs.Pour éviter toute disparité d'impédance, utiliser toujours lemême type de câble dans le réseau entier. Lors du raccor-dement d'un moteur au variateur, utiliser toujours un câblede moteur blindé.
Câble : paire torsadée blindée (STP)
Impédance : 120 ΩLongueur de câble : max. 1200 m (y compris les câbles dedérivation)
Max. 500 m de station à station
Installation Guide rapide de l'AF-600 FP
DET-759A/F 13
3 3
4 Démarrage et test de fonctionnement
4.1 Pré-démarrage
4.1.1 Inspection de sécurité
AVERTISSEMENTHAUTE TENSION !Si les connexions d'entrée et de sortie ont été raccordéesde manière incorrecte, il y a un risque de haute tension àces bornes. Si les fils d'alimentation de plusieurs moteurssont mal acheminés dans un même conduit, il existe unrisque de courant de fuite qui charge les condensateurs ausein du variateur, même si celui-ci est déconnecté del'entrée secteur. Pour le démarrage initial, ne faire aucunesupposition concernant les composants de puissance.Suivre les procédures de pré-démarrage. Le non-respect deces procédures pourrait entraîner des blessures ouendommager l'équipement.
1. L'alimentation d'entrée de l'unité doit êtredésactivée et verrouillée. Ne pas compter sur lessectionneurs du variateur pour l'isolation del'alimentation d'entrée.
2. Vérifier l'absence de tension aux bornes d'entréeL1 (91), L2 (92) et L3 (93), phase-phase et phase-terre.
3. Vérifier l'absence de tension aux bornes de sortie96 (U), 97 (V) et 98 (W), phase-phase et phase-terre.
4. Contrôler la continuité du moteur en mesurantles valeurs en ohms aux bornes U-V (96-97), V-W(97-98) et W-U (98-96).
5. Vérifier la bonne mise à la terre du variateur etdu moteur.
6. Inspecter le variateur pour détecter lesconnexions desserrées sur les bornes.
7. Noter les données de la plaque signalétique dumoteur suivantes : puissance, tension, fréquence,courant de pleine charge et vitesse nominale. Cesvaleurs sont nécessaires pour programmer lesdonnées de la plaque signalétique du moteurultérieurement.
8. Vérifier que la tension d'alimentation correspondà la tension du variateur et du moteur.
Démarrage et test de foncti... Guide rapide de l'AF-600 FP
14 DET-759A/F
44
4.1.2 Liste de vérification avant le démarrage
ATTENTIONAvant de mettre l'appareil sous tension, inspecter l'ensemble de l'installation de la façon décrite dans le Tableau 4.1. Cocherles éléments une fois l'inspection finie.
Inspecter Description Équipement auxiliaire • Rechercher les équipements auxiliaires, commutateurs, sectionneurs ou fusibles
d'entrée/disjoncteurs qui peuvent se trouver du côté puissance d'entrée duvariateur de fréquence ou du côté sortie du moteur. S'assurer qu'ils sont prêtspour une exploitation à plein régime.
• Vérifier la fonction et l'installation des capteurs utilisés pour le signal de retourvers le variateur.
• Retirer les bouchons de correction du facteur de puissance du ou des moteursle cas échéant.
Passage des câbles • Vérifier que le câblage de l'alimentation, le câblage du moteur et le câblage decommande sont séparés ou placés dans trois conduits métalliques distinctspour obtenir une isolation des bruits haute fréquence.
Câblage de commande • Rechercher d'éventuels fils cassés ou endommagés et des branchementsdesserrés.
• Vérifier que le câblage de commande est isolé de l'alimentation et du câblemoteur pour l'immunité au bruit.
• Vérifier la source de tension des signaux si nécessaire.
• L'utilisation de câble blindé ou de paire torsadée est recommandée. Vérifierque le blindage est correctement terminé.
Espace pour le refroidissement • Veiller à ce que le dégagement en haut et en bas soit adéquat pour assurer lacirculation de l'air à des fins de refroidissement.
Considérations CEM • Contrôler l'installation au regard de sa compatibilité électromagnétique.
Considérations environne-mentales
• Consulter l'étiquette de l'équipement pour connaître les limites de températureambiante de fonctionnement maximum.
• Les niveaux d'humidité doivent être de 5 à 95 % sans condensation.
Fusibles et disjoncteurs • Vérifier que les fusibles et les disjoncteurs sont adaptés.
• Vérifier que tous les fusibles sont correctement insérés et en bon état et quetous les disjoncteurs sont en position ouverte.
Mise à la terre • L'unité nécessite un fil de terre dédié depuis son châssis jusqu'à la terre dubâtiment.
• Vérifier que les mises à la terre sont correctes, étanches et exemptesd'oxydation.
• La mise à la terre vers un conduit ou le montage du panneau arrière sur unesurface métallique n'est pas considérée comme une mise à la terre adaptée.
Câble de puissance d'entrée etde sortie
• Rechercher d'éventuelles connexions desserrées.
• Vérifier que les câbles moteur et secteur passent par des conduits ou descâbles blindés séparés.
Intérieur du panneau • Vérifier que l'intérieur de l'unité est exempt de saletés, de particulesmétalliques, d'humidité et de corrosion.
Commutateurs • Vérifier que les paramètres du commutateur et du sectionneur sont réglés
correctement.
Démarrage et test de foncti... Guide rapide de l'AF-600 FP
DET-759A/F 15
4 4
Inspecter Description Vibrations • Vérifier que l'unité est montée solidement ou que des supports amortisseurs
sont utilisés si nécessaire.
• Rechercher tout niveau de vibrations inhabituel.
Tableau 4.1 Liste de vérification avant le démarrage
4.2 Application d'alimentation au Variateur
AVERTISSEMENTHAUTE TENSION !Les variateurs de fréquence contiennent des tensionsélevées lorsqu'ils sont reliés au secteur CA. L'installation, ledémarrage et la maintenance doivent être effectuésuniquement par du personnel qualifié. Le non-respect decette instruction peut entraîner le décès ou des blessuresgraves.
AVERTISSEMENTDÉMARRAGE IMPRÉVU !Lorsque le variateur est connecté à l'alimentation secteurCA, le moteur peut démarrer à tout moment. Le variateur,le moteur et tout équipement entraîné doivent être prêts àfonctionner. Le non respect de ces recommandations peutentraîner la mort, des blessures graves ou des dégâtsmatériels.
1. S'assurer que la tension d'entrée est équilibréedans une limite de 3 %. Si ce n'est pas le cas,corriger le déséquilibre de la tension d'entréeavant de continuer. Répéter la procédure aprèsavoir corrigé la tension.
2. S'assurer que le câblage des équipementsoptionnels éventuellement installés est adapté àl'application.
3. Veiller à ce que tous les dispositifs de l'opérateursoient réglés sur la position OFF. Les portes dupanneau doivent être fermées ou montées d'uncouvercle.
4. Mettre l'unité sous tension. NE PAS démarrer levariateur à ce moment. Pour les unités avec unsectionneur, tourner sur la position ON pourappliquer une tension au variateur.
4.3 Programmation opérationnelle de base
Les variateurs nécessitent une programmation de basepour fonctionner de manière optimale. La programmationde base prévoit la saisie des vitesses du moteur minimaleet maximale et des données de la plaque signalétique dumoteur pour le bon fonctionnement du moteur. Saisir lesdonnées selon la procédure suivante. Les réglages desparamètres recommandés sont prévus à des fins de
démarrage et de vérification. Les réglages de l'applicationpeuvent varier.
Saisir les données avec une tension appliquée, mais avantde faire fonctionner le variateur.
1. Appuyer sur [Quick Menu] sur le clavier.
2. Utiliser les touches de navigation pour accéder audémarrage rapide et appuyer sur [OK].
3. Sélectionner la langue puis appuyer sur [OK].Saisir ensuite les données du moteur dans lesparamètres P-02, P-03, P-06, P-07, F-04 et F-05(moteurs à induction uniquement, pour lesmoteurs PM, ignorer ces paramètres pourl'instant). Ces informations sont présentes sur laplaque signalétique du moteur. La structure dumenu rapide complet est indiquée dans la section.
P-07 Puissance moteur [kW] ouP-02 Puissance moteur [CV]
F-05 Tension nominale du moteur
F-04 Fréquence base
P-03 Courant moteur
P-06 Vitesse de base
4. Il est conseillé de régler le F-07 Temps d'accél. 1sur 60 secondes pour les ventilateurs ou 10secondes pour les pompes.
5. Il est conseillé de régler le F-08 Temps décél. 1 sur60 secondes pour les ventilateurs ou 10 secondespour les pompes.
6. Pour F-10, saisir le déclenchement 1 de lasurcharge électronique pour la protectionsurcharge de classe 20. Pour plus d'informations,se reporter à 3.4.1 Exigences.
7. Pour F-16 Vitesse moteur limite basse [Hz], saisir lesexigences de l'application. Si ces valeurs sontinconnues à cet instant, les valeurs suivantes sontrecommandées. Ces valeurs garantissent le bonfonctionnement initial du variateur. Cependant,prendre toute précaution nécessaire pour éviterd'endommager l'équipement. S'assurer que lesvaleurs recommandées sont sûres pour un usage
Démarrage et test de foncti... Guide rapide de l'AF-600 FP
16 DET-759A/F
44
dans le cadre des tests de fonctionnement avantde démarrer l'équipement.
Ventilateur = 20 Hz
Pompe = 20 Hz
Compresseur = 30 Hz
8. Dans F-15 Vitesse moteur limite haute [Hz], saisir lafréquence du moteur obtenue dansF-04 Fréquence base.
Ceci clôt la procédure de configuration rapide. Appuyer sur[Status] pour revenir à l'écran d'utilisation.
Au par. P-04 Réglage automatique, sélectionner Régl. autoréduit ou Régl. auto complet et suivre les instructionsaffichées à l'écran. Voir 4.4 Réglage automatique
4.4 Réglage automatique
Le réglage automatique est une procédure de test quimesure les caractéristiques électriques du moteur pouroptimiser la compatibilité entre le variateur et le moteur.
• Le variateur construit un modèle mathématiquedu moteur pour la régulation du courant dumoteur de sortie. La procédure teste égalementl'équilibre de la phase d'entrée de l'alimentationélectrique. Elle compare les caractéristiques dumoteur aux données saisies dans les paramètresP-02, P-03, P-06, P-07, F-04 et F-05.
• Cela ne démarre ni n'endommage le moteur.
• Il est parfois impossible d'effectuer une versioncomplète du test sur certains moteurs. Dans cecas, sélectionner Régl. auto réduit.
• Lorsqu'un filtre de sortie est raccordé au moteur,sélectionner Régl. auto réduit.
• Si des avertissements ou des alarmes seproduisent, consulter le chapitre 7 Avertissementset alarmes.
4.5 Contrôle de la rotation du moteur
Avant de faire fonctionner le variateur, vérifier la rotationdu moteur. Le moteur fonctionne un court instant à 5 Hzou à la fréquence minimale réglée au F-16 Vitesse moteurlimite basse [Hz].
1. Appuyer deux fois sur [Main Menu] sur le clavier.
2. Accéder au réglage des données paramètre, fairedéfiler jusqu'à P-## Données moteur et appuyersur [OK] pour accéder à ce niveau.
3. Accéder au par. P-08 Ctrl rotation moteur.
4. Appuyer sur [OK].
5. Accéder à Activé.
Le texte suivant s'affiche : Note! Mot. peut tourner dansmauvais sens.
6. Appuyer sur [OK].
7. Suivre les instructions à l'écran.
Pour changer le sens de rotation, mettre le variateur horstension et attendre que les circuits se déchargent complè-tement. Intervertir le branchement de deux des trois câblesdu moteur sur le côté moteur ou variateur de laconnexion.
4.6 Test de commande locale
ATTENTIONDÉMARRAGE DU MOTEUR !S'assurer que le moteur, le système et tous leséquipements rattachés sont prêts à démarrer. Il incombe àl'utilisateur de garantir le fonctionnement sûr dans toutesles conditions. S'ils n'étaient pas prêts, cela pourraitentraîner des blessures ou des dégâts matériels.
REMARQUE!La touche Hand du clavier transmet un ordre dedémarrage local au variateur. La touche OFF assure lafonction d'arrêt.Pendant l'exploitation en mode local, les flèches haut etbas sur le clavier augmentent et diminuent la sortie devitesse du variateur. Les touches fléchées gauche et droitedéplacent le curseur sur l'affichage numérique.
1. Appuyer sur [Hand].
2. Faire accélérer le variateur jusqu'à sa vitessemaximum en appuyant sur []. En déplaçant lecurseur à gauche du point décimal, il est possiblede modifier plus rapidement l'entrée.
3. Noter tout problème d'accélération.
4. Appuyer sur [OFF].
5. Noter tout problème de décélération.
Si des problèmes d'accélération surviennent :
• Si des avertissements ou des alarmes seproduisent, consulter le chapitre 7 Avertissementset alarmes.
• Vérifier que les données du moteur ont étécorrectement saisies.
• Augmenter le temps d'accélération au par.F-07 Temps d'accél. 1
• Augmenter la limite de courant au par.F-43 Limite de courant.
• Augmenter la limite de couple au par.F-40 Limiteur couple (entraînement).
Démarrage et test de foncti... Guide rapide de l'AF-600 FP
DET-759A/F 17
4 4
Si des problèmes de décélération sont décelés :
• Si des avertissements ou des alarmes seproduisent, consulter le chapitre 7 Avertissementset alarmes.
• Vérifier que les données du moteur ont étécorrectement saisies.
• Augmenter le temps de décélération au par.F-08 Temps décél. 1
Voir la section 7.1 Définitions des avertissements et desalarmes à propos de la réinitialisation du variateur après undéclenchement.
REMARQUE!Les sections 4.1 Pré-démarrage à 4.6 Test de commandelocale de ce chapitre concernent les procédures de misesous tension du variateur, de la programmation de base,de la configuration et du test de fonctionnement.
4.7 Démarrage du système
La procédure décrite dans cette section part du principeque le câblage par l'utilisateur et la programmation del'application sont achevés. Le chapitre apporte une aidepour cette tâche. La procédure suivante est recommandéeune fois que l'utilisateur a terminé la configuration del'application.
ATTENTIONDÉMARRAGE DU MOTEUR !S'assurer que le moteur, le système et tous leséquipements rattachés sont prêts à démarrer. Il incombe àl'utilisateur de garantir le fonctionnement sûr dans toutesles conditions d'exploitation. S'ils n'étaient pas prêts, celapourrait entraîner des blessures ou des dégâts matériels.
1. Appuyer sur [Auto].
2. S'assurer que les fonctions de contrôle externessont correctement câblées vers le variateur et quetoute la programmation est finie.
3. Appliquer un ordre de marche externe.
4. Ajuster la référence de la vitesse dans la plage devitesse.
5. Arrêter l'ordre de marche externe.
6. Noter tout problème.
Si des avertissements ou des alarmes se produisent,consulter le chapitre 7 Avertissements et alarmes.
Démarrage et test de foncti... Guide rapide de l'AF-600 FP
18 DET-759A/F
44
5 Interface utilisateur
5.1 Clavier
Le clavier est un ensemble composé d'un écran et detouches situé à l'avant de l'unité. Le clavier est l'interfaceutilisateur du variateur de fréquence.
Le clavier a plusieurs fonctions pour l'utilisateur :
• Démarrage, arrêt et vitesse de contrôle encommande locale
• Affichage des données d'exploitation, de l'état,des avertissements et mises en garde
• Programmation des fonctions du variateur defréquence
• Reset manuel du variateur de fréquence aprèsune panne lorsque le reset automatique estinactif
REMARQUE!Le contraste de l'affichage peut être réglé en appuyant sur[STATUS] et les touches haut/bas.
5.1.1 Disposition du Clavier
Le clavier est divisé en quatre groupes fonctionnels (voirIllustration 5.1).
Illustration 5.1 Clavier
a. Zone d'affichage.
b. Touches de menu de l'écran pour changerl'affichage afin de montrer les options d'état, laprogrammation ou l'historique des messagesd'erreur.
c. Touches de navigation pour les fonctions deprogrammation, le déplacement du curseur et lacommande de vitesse en mode local. Des voyantsd'état se trouvent aussi dans cette zone.
Interface utilisateur Guide rapide de l'AF-600 FP
DET-759A/F 19
5 5
d. Touches de modes d'exploitation et de réinitiali-sation.
5.1.2 Réglage des valeurs affichées sur leClavier
La zone d'affichage est activée lorsque le variateur defréquence est alimenté par la tension secteur, par uneborne du circuit CC ou par une alimentation 24 V externe.
L'information affichée sur le clavier peut être personnaliséepour l'application de l'utilisateur.
• Chaque lecture d'affichage a un paramètre qui luiest associé.
• Les options sont choisies dans le menu Processclavier.
• L'affichage 2 a une option possible d'affichageplus grand.
• L'état du variateur de fréquence sur la ligneinférieure de l'écran est généré automatiquementet ne peut être sélectionné.
Affichage Numéro de paramètre Réglage par défaut
1.1 K-20 Vitesse moteur [tr/min]
1.2 K-21 Courant moteur
1.3 K-22 Puissance du moteur(kW)
2 K-23 Fréquence du moteur
3 K-24 Référence en %
5.1.3 Touches de menu de l'affichage
Les touches de menu servent à l'accès aux menus, à laconfiguration des paramètres, à la navigation parmi lesmodes d'affichage d'état en fonctionnement normal et à lavisualisation des données de la mémoire des défauts.
Touche FonctionStatus Utiliser cette touche pour voir les informations
d'exploitation.
• En mode Auto, appuyer sur cette touche etla maintenir enfoncée pour basculer d'unécran de lecture d'état à un autre.
• Appuyer plusieurs fois dessus pour parcourirchaque écran d'état.
• Actionner et maintenir enfoncée la touche
[Status] et appuyer sur [] ou [] pour
régler la luminosité de l'écran.
• Le symbole dans l'angle supérieur droit del'écran montre le sens de rotation dumoteur et quel process est actif. Ceci n'estpas programmable.
Quick Menu Permet d'accéder aux paramètres de program-mation pour des instructions de configurationinitiale et de nombreuses instructions détailléespour l'application.
• Utiliser pour accéder au Démarrage rapide etsuivre les instructions étape par étape pourprogrammer la configuration basique duvariateur de fréquence.
• Utiliser pour accéder à Macros ventilat.,
Macros pompe, Macros compresseur ouBoucle fermée et suivre les instructions étapepar étape pour programmer les applications.
• Appuyer pour accéder à la tendance del'enregistrement en temps réel sur
l'affichage clavier.
• Appuyer pour accéder à la vérification desdonnées paramètre et contrôler les modifi-cations apportées au réglage des donnéesparamètre.
• Suivre la séquence des paramètres comme
présenté pour la configuration desfonctions.
Interface utilisateur Guide rapide de l'AF-600 FP
20 DET-759A/F
55
Touche FonctionMain Menu Permet d'accéder à tous les paramètres de
programmation.
• Appuyer deux fois sur cette touche pouraccéder à l'index le plus élevé.
• Actionner une fois pour revenir au dernierélément consulté.
• Appuyer sur la touche et la maintenirenfoncée pour saisir un numéro deparamètre afin d'y accéder directement.
Alarm Log Affiche une liste des avertissements actuels, les
10 dernières alarmes et le journal demaintenance.
• Pour obtenir des détails sur le variateur
avant qu'il ne soit passé en mode alarme,sélectionner le numéro de l'alarme à l'aidedes touches de navigation, puis appuyer sur
[OK].
5.1.4 Touches de navigation
Les touches de navigation servent à programmer desfonctions et à déplacer le curseur à l'écran. Elles peuventaussi permettre de commander la vitesse en mode local(hand). Trois voyants d'état du variateur se trouventégalement dans cette zone.
Touche FonctionBack Renvoie à l'étape ou à la liste du niveau précédent
de la structure de menu.
Cancel Annule la dernière modification ou commande tant
que le mode d'affichage n'a pas été modifié.
Info Utiliser Info pour lire une définition de la fonctionaffichée.
Touches denavigation
Utiliser les quatre flèches de navigation pour sedéplacer entre les options du menu.
Touche FonctionOK Utiliser OK pour accéder aux groupes de
paramètres ou pour activer un choix.
Couleur Voyant Fonction
Vert ON Le voyant ON est activé lorsque levariateur est alimenté par latension secteur, par une connexiondu circuit intermédiaire CC ou parune alimentation 24 V externe.
Jaune WARN Lorsque des conditions d'avertis-sement sont présentes, le voyantjaune WARN s'allume et un texteapparaît dans la zone d'affichagepour signaler le problème.
Rouge ALARM Une condition de panne entraînele clignotement du voyantd'alarme rouge et un messages'affiche.
5.1.5 Touches d'exploitation
Les touches d'exploitation se trouvent en bas du clavier.
Touche FonctionHand Appuyer sur cette touche pour démarrer le
variateur en commande locale.
• Utiliser les touches de navigation pourcontrôler la vitesse du variateur.
• Un signal d'arrêt externe via une entrée decommande ou la communication série annulela commande locale.
Off Arrête le moteur, mais ne coupe pas la tensionappliquée au variateur.
Auto Met le système en mode d'exploitation àdistance.
• Répond à un ordre de démarrage externe viades bornes de commande ou la communi-cation série.
• La référence de vitesse provient d'une sourceexterne.
Reset Réinitialise le variateur manuellement aprèsqu'une panne a été corrigée.
Interface utilisateur Guide rapide de l'AF-600 FP
DET-759A/F 21
5 5
5.2 Sauvegarde et copie des réglages desparamètres
Les données de programmation sont enregistrées eninterne sur le variateur.
• Les données peuvent être chargées dans lamémoire du clavier à des fins de sauvegarde.
• Une fois enregistrées sur le clavier, les donnéespeuvent être téléchargées vers le variateur.
• Elles peuvent aussi être téléchargées vers d'autresvariateurs de fréquence en raccordant le clavier àces unités et en téléchargeant les réglagesenregistrés. (Ceci est une méthode rapide pourprogrammer plusieurs unités avec les mêmesréglages.)
• L'initialisation du variateur pour restaurer lesréglages d'usine par défaut ne modifie pas lesdonnées stockées dans la mémoire du clavier.
AVERTISSEMENTDÉMARRAGE IMPRÉVU !Lorsque le variateur est connecté à l'alimentation secteurCA, le moteur peut démarrer à tout moment. Le variateur,le moteur et tout équipement entraîné doivent être prêts àfonctionner. Le non respect de ces recommandations peutentraîner la mort, des blessures graves ou des dégâtsmatériels.
5.2.1 Chargement de données vers leclavier
1. Appuyer sur [OFF] pour arrêter le moteur avantde charger ou télécharger des données.
2. Aller au par. K-50 Copie clavier.
3. Appuyer sur [OK].
4. Sélectionner Lect.PAR.clavier.
5. Appuyer sur [OK]. Une barre de progressionindique l'avancement du chargement.
6. Appuyer sur [Hand] ou [Auto] pour revenir aufonctionnement normal.
5.2.2 Téléchargement de données depuisle clavier
1. Appuyer sur [OFF] pour arrêter le moteur avantde charger ou télécharger des données.
2. Aller au par. K-50 Copie clavier.
3. Appuyer sur [OK].
4. Sélectionner Ecrit.PAR. clavier.
5. Appuyer sur [OK]. Une barre de progressionindique l'avancement du téléchargement.
6. Appuyer sur [Hand] ou [Auto] pour revenir aufonctionnement normal.
5.3 Restauration des réglages par défaut
ATTENTIONL'initialisation restaure les réglages d'usine par défaut del'unité. Tous les enregistrements de programmation, dedonnées du moteur, de localisation et de surveillance sontperdues. Le chargement des données vers le clavierpermet de réaliser une sauvegarde avant l'initialisation.
Pour restaurer les paramètres du variateur aux valeurs pardéfaut, initialiser le variateur de fréquence. L'initialisationpeut se faire via le par. H-03 Restaur. régl.usine ou manuel-lement.
• L'initialisation à l'aide du par. H-03 Restaur.régl.usine ne modifie pas les données du variateurtelles que les heures de fonctionnement, lessélections de communication série, les réglagesdu menu personnel, la mémoire des défauts, lejournal d'alarme et les autres fonctions desurveillance.
• Le recours au par. H-03 Restaur. régl.usine estgénéralement recommandé.
• L'initialisation manuelle efface toutes les donnéesdu moteur, de programmation, de localisation etde surveillance et restaure les réglages d'usinepar défaut.
5.3.1 Initialisation recommandée
1. Appuyer deux fois sur [Main Menu] pour accéderaux paramètres.
2. Accéder au par. H-03 Restaur. régl.usine.
3. Appuyer sur [OK].
4. Défiler jusqu'à [2] Restaura° régl.usine.
5. Appuyer sur [OK].
6. Mettre l'unité hors tension et attendre quel'affichage s'éteigne.
7. Mettre l'unité sous tension.
Les réglages des paramètres par défaut sont restaurés lorsdu démarrage. Celui-ci peut prendre plus de temps que lanormale.
8. L'alarme 80 s'affiche.
9. Appuyer sur [Reset] pour revenir au moded'exploitation.
Interface utilisateur Guide rapide de l'AF-600 FP
22 DET-759A/F
55
5.3.2 Initialisation manuelle
1. Mettre l'unité hors tension et attendre quel'affichage s'éteigne.
2. Appuyer en même temps sur [Status], [MainMenu] et [OK] et les maintenir enfoncées tout enmettant l'unité sous tension.
Les réglages des paramètres par défaut sont restauréspendant le démarrage. Celui-ci peut prendre plus de tempsque la normale.
L'initialisation manuelle ne réinitialise pas les informationssuivantes du variateur :
• ID-00 Heures ss tens°
• ID-03 Mise sous tension
• ID-04 Surtemp.
• ID-05 Surtension
Interface utilisateur Guide rapide de l'AF-600 FP
DET-759A/F 23
5 5
6.1.1 Structure du menu principalK-
## P
roce
ss c
lavi
erK-
37 A
ffich
. tex
te 1
K-8#
Lec
t. jo
urs,
dat
e/h
F-2#
Fon
dam
enta
l 2E-
## E
/S d
igita
les
K-0#
Rég
l. ba
siq.
cla
vier
K-38
Affi
ch. t
exte
2K-
81 J
ours
de
fct
F-24
Tps
mai
ntie
nE-
0# E
ntré
es d
igita
les
K-01
Lan
gue
K-39
Affi
ch. t
exte
3K-
82 J
ours
de
fct
supp
.F-
26 B
ruit
(fré
q.po
rt.)
E-00
Mod
e E/
S di
gita
l
K-02
Uni
té v
it. m
ot.
K-4#
Tou
ches
du
cla
vier
K-83
Jou
rs d
'arr
êt s
upp.
F-27
Ton
alité
mot
. alé
atoi
reE-
01 E
.dig
it.bo
rn.1
8
K-03
Rég
lage
s ré
gion
aux
K-40
Tou
che
[Han
d] d
u c
lavi
erK-
89 L
ectu
re d
ate
et h
eure
F-3#
Fon
dam
enta
l 3E-
02 E
.dig
it.bo
rn.1
9
K-04
Éta
t ex
ploi
. à m
ise
ss t
ensi
onK-
41 T
ouch
e [O
ff] d
u c
lavi
erF-
## P
ar. f
onda
men
t.F-
37 T
ype
mod
ulat
ion
av.
E-03
E.d
igit.
born
.27
K-05
Uni
té m
ode
loca
lK-
42 T
ouch
e [A
uto]
sur
cla
vier
F-0#
Fon
dam
enta
l 0F-
38 S
urm
odul
atio
nE-
04 E
.dig
it.bo
rn.2
9
K-1#
Ges
t° p
roc.
clav
ier
K-43
Tou
che
[Res
et]
du c
lavi
erF-
01 R
égl.
de fr
éque
nce
1F-
4# F
onda
men
tal 4
E-05
E.d
igit.
born
.32
K-10
Pro
cess
act
uel
K-5#
Cop
ie/S
auve
gard
eF-
02 M
étho
de d
e fc
tF-
40 L
imite
ur c
oupl
e (e
ntra
înem
ent)
E-06
E.d
igit.
born
.33
K-11
Pro
gram
mer
pro
cess
K-50
Cop
ie c
lavi
erF-
03 F
rq.so
rt.li
m.h
te 1
F-41
Lim
iteur
cou
ple
(frei
nage
)E-
1# R
amp.
acc
/déc
sup
p
K-12
Ce
régl
age
lié à
K-51
Cop
ie p
roce
ssF-
04 F
réqu
ence
bas
eF-
43 L
imite
de
cour
ant
E-10
Tem
ps d
'acc
él. 2
K-13
Lec
ture
: Rég
lage
s jo
ints
K-6#
Pro
tect
ion
par
mot
de
pass
eF-
05 T
ensi
on n
omin
ale
dum
oteu
rF-
5# R
éf. é
tend
ues
E-11
Tem
ps d
écél
. 2
K-14
Lec
ture
: Edi
tion
régl
ages
/ c
anal
K-60
Mt
de p
asse
men
u p
rinc.
F-07
Tem
ps d
'acc
él. 1
F-52
Réf
éren
ce m
inim
ale
E-2#
Sor
ties
digi
tale
s
K-2#
Affi
chag
e cl
avie
r
K-61
Acc
ès m
enu
prin
c. s
s m
t de
pass
eF-
08 T
emps
déc
él. 1
F-53
Réf
. max
.E-
20 S
.dig
it.bo
rn.2
7
K-20
Affi
ch. l
igne
1.1
pet
itK-
65 M
ot d
e pa
sse
men
u ra
pide
F-1#
Fon
dam
enta
l 1F-
54 F
onct
ion
réfé
renc
eE-
21 S
.dig
it.bo
rn.2
9
K-21
Affi
ch. l
igne
1.2
pet
itK-
66 A
ccès
men
u ra
pide
ss
mt
depa
sse.
F-10
Sur
char
ge é
lect
roni
que
F-6#
Réf
éren
ces
E-24
Fon
ctio
n re
lais
K-22
Affi
ch. l
igne
1.3
pet
itK-
7# R
égl.
horlo
geF-
11 V
entil
. ext
. mot
.F-
64 R
éf.p
rédé
f.rel
ativ
eE-
26 R
elai
s, r
etar
d O
N
K-23
Affi
ch. l
igne
2 g
rand
K-70
Rég
ler
date
&he
ure
F-12
Ent
rée
ther
mis
tanc
e m
ot.
F-9#
Pot
entio
mèt
re d
ig.
E-27
Rel
ais,
ret
ard
OFF
K-24
Affi
ch. l
igne
3 g
rand
K-71
For
mat
dat
eF-
15 V
itess
e m
oteu
r lim
iteha
ute
[Hz]
F-90
Dim
ensi
on d
e pa
sE-
5# M
ode
E/S
/ Ex
tens
ion
E/S
K-25
Dém
arra
ge r
apid
eK-
72 F
orm
at h
eure
F-16
Vite
sse
mot
eur
limite
bass
e [H
z]F-
91 T
ps a
ccél
./déc
él.
E-51
Mod
e bo
rn.2
7
K-3#
Lec
t.par
amét
r. cl
avie
rK-
74 H
eure
d'é
té
F-17
Vit.
mot
., lim
ite s
upér
. [tr
/
min
]F-
92 R
esta
urat
ion
de
puis
sanc
eE-
52 M
ode
born
.29
K-30
Uni
té p
our
affic
h. c
lient
.K-
76 D
ébut
heu
re d
'été
F-18
Vit.
mot
., lim
ite in
fér.
[tr/
min
]F-
93 L
imite
max
imal
eE-
53 E
.dig
it.bo
rn. X
30/2
K-31
Val
eur
min
. de
lect
.par
amét
r.K-
77 F
in h
eure
d'é
té
F-94
Lim
ite m
inim
ale
E-54
E.d
igit.
born
. X30
/3
K-32
Val
eur
max
de
lect
.par
amét
r.K-
79 D
éf.h
orlo
ge
F-95
Ret
ard
ram
pe a
ccél
./déc
él.
E-55
E.d
igit.
born
. X30
/4
Programmation Guide rapide de l'AF-600 FP
24 DET-759A/F
66
E-56
S.d
igit.
born
. X30
/6 (O
PCG
PIO
)E-
96 T
empo
. pré
défin
ie s
ortie
impu
lsio
ns 2
9P-
07 P
uiss
ance
mot
eur
[kW
]H
-5#
Proc
.indé
p. c
harg
eA
N-1
# En
trée
AN
A 5
3
E-57
S.d
igit.
born
. X30
/7 (O
PCG
PIO
)E-
97 C
trl b
us s
ortie
impu
ls.X
30/6
P-08
Ctr
l rot
atio
n m
oteu
rH
-58
Flys
tart
Tes
t Pu
lses
Cur
rent
AN
-10
Ech.
min
.U/b
orn.
53
E-6#
Ent
rée
impu
lsio
nsE-
98 T
empo
. pré
déf.s
ortie
impu
ls.X
30/6
P-09
Com
pens
atio
n d
u g
lisse
men
tH
-59
Flys
tart
Tes
t Pu
lses
Fre
quen
cyA
N-1
1 Ec
h.m
ax.U
/bor
n.53
E-60
F.b
as b
orn.
29C-
## F
onct
ions
de
ctrl
de
fréq
.P-
10 C
ste
tps
com
p.gl
iss.
H-6
# Pr
oc.d
épen
d. c
harg
eA
N-1
2 Ec
h.m
in.I/
born
.53
E-61
F.h
aute
bor
n.29
C-0#
Fon
ctio
ns d
e ct
rl d
e fr
éq.
P-3#
Don
nées
av.
mot
eur
H-6
4 A
mor
t. ré
sona
nce
AN
-13
Ech.
max
.I/bo
rn.5
3
E-62
Val
.ret./
Réf.b
as.b
orn.
29
C-01
Sau
t de
fréq
. de
[Hz]
P-30
Rés
ista
nce
stat
or (R
s)H
-65
Tps
amor
t.res
onan
ceA
N-1
4 Va
l.ret
./Réf
.bas
.bor
n. 5
3
E-63
Val
.ret./
Réf.h
aut.b
orn.
29
C-02
Sau
t de
vit.
de
[tr/
mn]
P-31
Rés
ista
nce
roto
r (R
r)H
-7#
Ave
rtis
sem
ents
régl
able
sA
N-1
5 Va
l.ret
./Réf
.hau
t.bor
n. 5
3
E-64
Tps
filtr
e pu
lses
/29
C-03
Sau
t de
vit.
à [t
r/m
n]P-
35 R
éact
ance
prin
cipa
le (X
h)H
-70
Ave
rtis
. cou
rant
bas
AN
-16
Cons
t.tps
.fil.b
orn.
53
E-65
F.b
as b
orn.
33C-
04 S
aut
de fr
éq. à
[Hz]
P-36
Rés
ista
nce
pert
e de
fer
(Rfe
)H
-71
Ave
rtis
. cou
rant
hau
tA
N-1
7 Zé
ro s
igna
l bor
ne 5
3
E-66
F.h
aute
bor
n.33
C-05
Fré
q. m
ultip
le 1
-8H
-##
Para
mèt
res
haut
e pe
rfH
-72
Ave
rtis
. vite
sse
bass
eA
N-2
# En
trée
AN
A 5
4
E-67
Val
.ret./
Réf.b
as.b
orn.
33
C-2#
Rég
l. jo
ggin
gH
-0#
Opé
ratio
ns h
aute
per
fH
-73
Ave
rtis
. vite
sse
haut
eA
N-2
0 Ec
h.m
in.U
/bor
n.54
E-68
Val
.ret./
Réf.h
aut.b
orn.
33
C-20
Fré
q.Jo
g. [H
z]H
-03
Rest
aur.
régl
.usi
neH
-74
Ave
rtis
. réf
éren
ce b
asse
AN
-21
Ech.
max
.U/b
orn.
54
E-69
Tps
filtr
e pu
lses
/33
C-21
Fré
q.Jo
g. [t
r/m
in]
H-0
4 A
uto-
rese
t (n
b)H
-75
Ave
rtis
. réf
éren
ce h
aute
AN
-22
Ech.
min
.I/bo
rn.5
4
E-7#
Sor
tie im
puls
ions
C-22
Tps
acc
él. e
t dé
cél.
jog.
H-0
5 Re
set
auto
(int
erva
lle d
e re
set)
H-7
6 A
vert
is.re
tour
bas
AN
-23
Ech.
max
.I/bo
rn.5
4
E-70
Fré
q.pu
ls./S
.bor
n.27
C-3#
Fré
q. ré
gl. 2
et
3H
-06
Fct
vent
ilate
urH
-77
Ave
rtis
.reto
ur h
aut
AN
-24
Val.r
et./R
éf.b
as.b
orn.
54
E-71
Fré
q. m
ax. s
ortie
impu
lsio
ns 2
7C-
30 C
trl d
e fr
éque
nce
2H
-08
Verr
ouill
age
inve
rsio
nH
-78
Surv
. pha
se m
ot.
AN
-25
Val.r
et./R
éf.h
aut.b
orn.
54
E-72
Fré
q.pu
ls./S
.bor
n.29
C-34
Ctr
l de
fréq
uenc
e 3
H-0
9 M
ode
dém
ar.
H-8
# Ré
glag
es a
rrêt
sA
N-2
6 Co
nst.t
ps.fi
l.bor
n.54
E-74
Fré
q. m
ax. s
ortie
impu
lsio
ns 2
9C-
4# R
égl.
saut
fréq
. sem
i-aut
oH
-3#
Vit.
arr
êtH
-80
Fonc
tion
à l'
arrê
tA
N-2
7 Zé
ro s
igna
l bor
ne 5
4
E-75
Fré
q.pu
ls./S
.bor
n.X3
0/6
C-40
Sau
t fr
éq. s
emia
uto
H-3
6 A
rrêt
vit.
bas
se [t
r/m
in]
H-8
1 Vi
t. m
in. p
our
fonc
t. à
l'arr
êt [t
r/m
in]
AN
-3#
Entr
ée A
NA
X30
/11
E-76
Fré
q. m
ax. s
ortie
impu
lsio
ns X
30/6
P-##
Don
nées
mot
.H
-37
Arr
êt v
it. b
asse
[Hz]
H-8
2 Vi
t. m
in. p
our
fonc
t. à
l'arr
êt [H
z]A
N-3
0 Ec
h.m
in.U
/bor
n. X
30/1
1
E-9#
Con
trôl
e pa
r bu
sP-
0# D
onné
es m
ot.
H-4
# Ré
gl. a
vanc
ésA
N-#
# E/
S an
a.A
N-3
1 Ec
h.m
ax.U
/bor
n. X
30/1
1
E-90
Ctr
l bus
sor
tie d
ig.&
rela
isP-
02 P
uiss
ance
mot
eur
[CV]
H-4
0 M
ode
Conf
ig.
AN
-0#
Mod
e E/
S an
a.A
N-3
4 Va
l. re
t./Ré
f.bas
.bor
n. X
30/1
1
E-93
Ctr
l par
bus
sor
tie im
puls
ions
27
P-03
Cou
rant
mot
eur
H-4
3 Ca
ract
.cou
ple
AN
-00
Tem
poris
atio
n/60
AN
-35
Val.
ret./
Réf.h
aut.b
orn.
X30
/11
E-94
Tem
po. p
rédé
finie
sor
tieim
puls
ions
27
P-04
Rég
lage
aut
omat
ique
H-4
8 Cl
ockw
ise
Dire
ctio
nA
N-0
1 Fo
nctio
n/Te
mpo
60A
N-3
6 Co
nst.
tps
filtr
e bo
rne
X30/
11
E-95
Ctr
l par
bus
sor
tie im
puls
ions
29
P-06
Vite
sse
de b
ase
A
N-0
2 Fo
nctio
n/te
mpo
60 m
ode
ince
ndie
AN
-37
Zéro
sig
nal b
orn
X30
/11
Programmation Guide rapide de l'AF-600 FP
DET-759A/F 25
6 6
AN
-4#
Entr
ée A
NA
X30
/12
SP-#
# Fo
nctio
ns s
péci
ales
SP-5
# En
viro
nnem
ent
O-1
3 M
ot é
tat
conf
igur
able
O-8
# D
iagn
ostic
s po
rt v
aria
teur
AN
-40
Ech.
min
.U/b
orn.
X30
/12
SP-1
# Li
gne
on/o
ffSP
-50
Filtr
e RF
IO
-3#
Régl
. por
t va
riate
urO
-80
Com
pt.m
essa
ge b
us
AN
-41
Ech.
max
.U/b
orn.
X30
/12
SP-1
0 Pa
nne
de li
gne
SP-5
1 D
C L
ink
Com
pens
atio
nO
-30
Prot
ocol
eO
-81
Com
pt.e
rreu
r bu
s
AN
-44
Val.
ret./
Réf.b
as.b
orn.
X30
/12
SP-1
1 Te
nsio
n li
gne
si p
anne
ent
rée
SP-5
3 Su
rvei
llanc
e ve
ntila
teur
O-3
1 A
dres
seO
-82
Com
pt.m
essa
ge e
scla
ve
AN
-45
Val.
ret./
Réf.h
aut.b
orn.
X30
/12
SP-1
2 Fo
nct.s
ur d
ésiq
ui.li
gne
SP-5
5 O
utpu
t Fi
lter
O-3
2 Vi
t. T
rans
. por
t va
riate
urO
-83
Com
pt.e
rreu
r es
clav
e
AN
-46
Cons
t. t
ps fi
ltre
born
e X3
0/12
SP-2
# Fo
nctio
ns re
set
SP-5
9 A
ctua
l Num
ber
of In
vert
erU
nits
O-3
3 Pa
rité
port
var
iate
urO
-89
Com
pt. d
iagn
ostic
s
AN
-47
Zéro
sig
nal b
orn
X30
/12
SP-2
3 Ré
glag
e co
de d
e ty
peSP
-6#
Déc
lass
emen
t au
toO
-34
Estim
ated
cyc
le t
ime
O-9
# Bu
s jo
g./r
etou
r
AN
-5#
Sort
ie A
NA
42
SP-2
5 D
élai
s A
l./C.
limit
?SP
-60
Fonc
tion
en
sur
tem
péra
ture
O-3
5 Re
tard
rép
onse
min
.O
-90
Vite
sse
Bus
Jog
1
AN
-50
S.bo
rn.4
2SP
-26
Tem
ps e
n U
lim
it.SP
-61
Fonc
t. e
n s
urch
arge
varia
teur
O-3
6 Re
tard
rép
onse
max
O-9
1 Vi
tess
e Bu
s Jo
g 2
AN
-51
Eche
lle m
in s
.bor
n.42
SP-2
8 Ré
glag
es p
rodu
ctio
nSP
-62
Cour
. déc
lass
.surc
h.va
riate
urO
-37
Reta
rd in
ter-
char
max
O-9
4 Re
tour
du
bus
1
AN
-52
Eche
lle m
ax s
.bor
n.42
SP-2
9 Co
de s
ervi
ceO
-##
Opt
ions
/ C
omm
sO
-4#
Déf
.pro
toc.
var.M
CO
-95
Reto
ur d
u b
us 1
AN
-53
Ctrl
bus
sor
tie b
orn.
42
SP-3
# Ct
rl I
lim. c
oura
ntO
-0#
Régl
. gén
érau
xO
-40
Séle
ctio
n T
élég
ram
me
O-9
6 Re
tour
bus
3
AN
-54
Tem
po p
réré
glée
sor
tie b
orn.
42
SP-3
0 Ct
rl.I l
imite
, Gai
n P
O-0
1 Ty
pe c
ontr
ôle
O-4
2 Co
nfig
. écr
iture
PCD
AO
-##
Opt
ion
E/S
ana
.
AN
-6#
Sort
ie A
NA
X30
/8SP
-31
Ctrl.
I lim
ite, t
ps In
tég.
O-0
2 So
urce
con
trôl
eO
-43
Conf
ig. l
ectu
re P
CDA
O-0
# M
ode
E/S
ana.
AN
-60
Sort
ie b
orne
X30
/8SP
-32
Curr
ent
Lim
Ctr
l, Fi
lter
Tim
eO
-03
Mot
de
ctrl.
Act
ion
dép
as.tp
sO
-5#
Dig
ital/B
usA
O-0
0 M
ode
born
e X4
2/1
AN
-61
Eche
lle m
in s
.bor
n.X3
0/8
SP-4
# Éc
o. d
'éne
rgie
O-0
4 M
ot d
e ct
rl.Fo
nct.d
épas
.tps
O-5
0 Ro
ue li
bre
AO
-01
Mod
e bo
rne
X42/
3
AN
-62
Eche
lle m
ax s
.bor
n.X3
0/8
SP-4
0 N
ivea
u V
TO
-05
Fonc
tion
fin
dép
ass.
tps.
O-5
2 Sé
lect
.frei
n C
CA
O-0
2 M
ode
born
e X4
2/5
AN
-63
Ctrl
par
bus
sor
tie b
orne
X30
/8SP
-41
Mag
nétis
. min
. pou
r éc
o. d
'éne
rgie
O-0
6 Re
set
dépa
s. t
emps
O-5
3 Sé
lect
.dém
.A
O-1
# En
trée
AN
A X
42/1
AN
-64
Tem
po p
rédé
finie
sor
tie b
orne
X30/
8SP
-42
Fréq
. min
. pou
r éc
o. d
'éne
rgie
O-0
7 A
ctiv
atio
n d
iagn
ostic
O-5
4 Sé
lect
.Inve
rs.
AO
-10
Éch.
min
.U/b
orn.
X42
/1
SP
-43
Cos
phi m
oteu
rO
-1#
Régl
. con
trôl
eO
-55
Séle
ct.p
roc.
AO
-11
Éch.
max
.U/b
orn.
X42
/1
O-1
0 Pr
ofil
mot
con
trôl
eO
-56
Séle
ct. r
éf. p
ar d
éfau
tA
O-1
4 Va
l. re
t./Ré
f.bas
.bor
n. X
42/1
Programmation Guide rapide de l'AF-600 FP
26 DET-759A/F
66
AO
-15
Val.
ret./
Réf.h
aut.b
orn
X42
/1A
O-6
# So
rtie
AN
A X
42/1
1PB
-94
Para
mèt
res
mod
ifiés
(5)
EN-3
3 CI
P Re
visi
onBN
-73
Cadr
es in
fo m
ax M
S/TP
AO
-16
Cons
t.tps
.fil.
born
e X4
2/1
AO
-60
Sort
ie b
orne
X42
/11
EN-#
# Et
hern
etEN
-34
CIP
Prod
uct
Code
BN-7
4 "S
tart
up I
am"
AO
-17
Zéro
sig
nal b
orn
X42
/1A
O-6
1 Ec
helle
min
s.b
orn.
X42/
11EN
-0#
Régl
ages
IPEN
-8#
Aut
res
serv
ices
Eth
erne
tBN
-75
Initi
alis
. mot
de
pass
e
AO
-2#
Entr
ée A
NA
X42
/3A
O-6
2 Ec
helle
max
s.b
orn.
X42/
11EN
-00
IP A
ddre
ss A
ssig
nmen
tEN
-80
FTP
Serv
erD
N-#
# Bu
s ré
seau
CA
N
AO
-21
Éch.
max
.U/b
orn.
X42
/3A
O-6
3 Ct
rl p
ar b
us s
ortie
bor
ne X
42/1
1EN
-01
IP A
ddre
ssEN
-81
HTT
P Se
rver
DN
-0#
Régl
.s c
omm
uns
AO
-21
Éch.
max
.U/b
orn.
X42
/3A
O-6
4 Te
mpo
pré
défin
ie s
ortie
bor
neX4
2/11
EN-0
2 Su
bnet
Mas
kEN
-82
SMTP
Ser
vice
DN
-00
Prot
ocol
e D
evic
eNet
AO
-24
Val.
ret./
Réf.b
as.b
orn
X42
/3PB
-##
Prof
ibus
EN-0
3 D
efau
lt G
atew
ayEN
-89
Tran
spar
ent
Sock
etCh
anne
l Por
tD
N-0
1 Sé
lect
ion
de
la v
itess
e de
tran
smis
sion
AO
-25
Val.
ret./
Réf.h
aut.b
orn
X42
/3PB
-15
Conf
ig. é
critu
re P
CDEN
-04
DH
CP S
erve
rEN
-9#
Serv
ices
Eth
erne
t av
ancé
sD
N-0
2 M
AC
ID
AO
-26
Cons
t.tps
.fil.
born
e X4
2/3
PB-1
6 Co
nfig
. lec
ture
PCD
EN-0
5 Le
ase
Expi
res
EN-9
0 Ca
ble
Dia
gnos
ticD
N-0
5 Cp
tr le
ctur
e er
reur
s tr
ansm
is.
AO
-27
Zéro
sig
nal b
orn
X42
/3PB
-18
Adr
esse
sta
tion
EN-0
6 N
ame
Serv
ers
EN-9
1 M
DI-X
DN
-06
Cptr
lect
ure
erre
urs
reçu
es
AO
-3#
Entr
ée A
NA
X42
/5PB
-22
Séle
ctio
n T
élég
ram
me
EN-0
7 D
omai
n N
ame
EN-9
2 IG
MP
Snoo
ping
DN
-07
Cptr
lect
ures
val
.bus
dés
act.
AO
-30
Éch.
min
.U/b
orn.
X42
/5PB
-23
Sign
aux
pour
PA
REN
-08
Hos
t N
ame
EN-9
3 Ca
ble
Erro
r Le
ngth
DN
-1#
Dev
iceN
et
AO
-31
Éch.
max
.U/b
orn.
X42
/5PB
-27
Editi
on p
aram
.EN
-09
Phys
ical
Add
ress
EN-9
4 Br
oadc
ast
Stor
mPr
otec
tion
DN
-10
PID
pro
c./S
élec
t.typ
e do
nnée
s
AO
-34
Val.
ret./
Réf.b
as.b
orn.
X42
/5PB
-28
CTRL
pro
cess
EN-1
# Pa
ram
ètre
s de
la li
aiso
n E
ther
net
EN-9
5 Br
oadc
ast
Stor
m F
ilter
DN
-11
Proc
./Ecr
it.co
nfig
.don
nées
AO
-35
Val.
ret./
Réf.h
aut.b
orn
X42
/5PB
-53
Mot
d'a
vert
isse
men
t pr
ofib
us.
EN-1
0 Li
nk S
tatu
sEN
-98
Inte
rfac
e Co
unte
rsD
N-1
2 Pr
oc./L
ect.c
onfig
.don
nées
AO
-36
Cons
t.tps
.fil.
born
e X4
2/5
PB-6
3 Vi
t. Tr
ans.
réel
leEN
-11
Link
Dur
atio
nEN
-99
Med
ia C
ount
ers
DN
-13
Ave
rtis
.par
.
AO
-37
Zéro
sig
nal b
orn
X42
/5PB
-70
Prog
ram
mer
pro
cess
EN-1
2 A
uto
Neg
otia
tion
LN-#
# LO
NW
ORK
SD
N-1
4 Ré
f.NET
AO
-4#
Sort
ie A
NA
X42
/7PB
-71
Sauv
.Don
nées
Pro
fibus
EN-1
3 Li
nk S
peed
LN-0
# ID
Lon
Wor
ksD
N-1
5 Ct
rl.N
ET
AO
-40
Sort
ie b
orne
X42
/7PB
-72
Rese
t Va
r.Pro
fibus
EN-1
4 Li
nk D
uple
xLN
-00
ID N
euro
nD
N-2
# Fi
ltres
CO
S
AO
-41
Eche
lle m
in s
.bor
n.X4
2/7
9-75
DO
Iden
tific
atio
nEN
-2#
Don
nées
de
proc
ess
LN-1
# Fo
nctio
ns L
ON
DN
-20
Filtr
e CO
S 1
AO
-42
Eche
lle m
ax s
.bor
n.X4
2/7
PB-8
0 Pa
ram
ètre
s dé
finis
(1)
EN-2
0 Co
ntro
l Ins
tanc
eLN
-10
Prof
il va
riate
urD
N-2
1 Fi
ltre
COS
2
AO
-43
Ctrl
par
bus
sor
tie b
orne
X42
/7PB
-81
Para
mèt
res
défin
is (2
)EN
-21
Proc
ess
Dat
a Co
nfig
Writ
eLN
-15
Mot
ave
rtis
. LO
ND
N-2
2 Fi
ltre
COS
3
AO
-44
Tem
po p
rédé
finie
sor
tie b
orne
X42/
7PB
-82
Para
mèt
res
défin
is (3
)EN
-22
Proc
ess
Dat
a Co
nfig
Rea
dLN
-17
Révi
sion
XIF
DN
-23
Filtr
e CO
S 4
AO
-5#
Sort
ie A
NA
X42
/9PB
-83
Para
mèt
res
défin
is (4
)EN
-28
Stor
e D
ata
Valu
esLN
-18
Révi
sion
Lon
Wor
ksD
N-3
# A
ccès
par
am.
AO
-50
Sort
ie b
orne
X42
/9PB
-84
Para
mèt
res
défin
is (5
)EN
-29
Stor
e A
lway
sLN
-2#
Acc
ès p
aram
. LO
ND
N-3
0 In
dice
de
tabl
eau
AO
-51
Eche
lle m
in s
.bor
n.X4
2/9
PB-9
0 Pa
ram
ètre
s m
odifi
és (1
)EN
-3#
Ethe
rNet
/IPLN
-21
Stoc
k.va
l.don
nées
DN
-31
Stoc
k.va
l.don
nées
AO
-52
Eche
lle m
ax s
.bor
n.X4
2/9
PB-9
1 Pa
ram
ètre
s m
odifi
és (2
)EN
-30
War
ning
Par
amet
erBN
-##
BACn
etD
N-3
2 Ré
visi
on D
evic
eNet
AO
-53
Ctrl
par
bus
sor
tie b
orne
X42
/9PB
-92
Para
mèt
res
mod
ifiés
(3)
EN-3
1 N
et R
efer
ence
BN-7
0 In
stan
ce d
ispo
sitif
BA
Cnet
DN
-33
Touj
ours
sto
cker
AO
-54
Tem
po p
rédé
finie
sor
tie b
orne
X42/
9PB
-93
Para
mèt
res
mod
ifiés
(4)
EN-3
2 N
et C
ontr
olBN
-72
Maî
tres
max
MS/
TPD
N-3
4 Co
de p
rodu
it D
evic
eNet
Programmation Guide rapide de l'AF-600 FP
DET-759A/F 27
6 6
ID-#
# In
fo.v
aria
teur
ID-4
2 Te
nsio
nD
R-12
Ten
sion
nom
inal
e du
mot
eur
DR-
6# E
ntré
es&
sort
ies
DR-
95 M
ot é
tat
élar
gi 2
ID-0
# D
onné
es e
xplo
it.ID
-43
Vers
ion
logi
ciel
DR-
13 F
réqu
ence
DR-
60 E
ntré
e di
g.D
R-96
Mot
mai
nten
ance
ID-0
0 H
eure
s ss
ten
s°ID
-44
N°
mod
èle
GE
DR-
14 C
oura
nt m
oteu
rD
R-61
Rég
l.com
mut
.bor
n.53
LG-#
# Jo
urn.
/éta
ts o
pt.E
/S
ID-0
1 H
eure
s fo
nctio
n.ID
-45
Code
com
posé
var
DR-
15 F
réqu
ence
[%]
DR-
62 E
ntré
e A
NA
53
LG-0
# Jo
urna
l mai
nten
.
ID-0
2 Co
mpt
eur
kWh
ID-4
6 N
° pr
odui
t G
ED
R-16
Cou
ple
[Nm
]D
R-63
Rég
l.com
mut
.bor
n.54
LG-0
0 Jo
urna
l mai
nten
.: él
émen
t
ID-0
3 M
ise
sous
ten
sion
ID-4
7 N
° m
odèl
e ca
rte
puis
sanc
e G
ED
R-17
Vite
sse
mot
eur
[tr/
min
]D
R-64
Ent
rée
AN
A 5
4LG
-01
Jour
nal m
aint
en.:
actio
n
ID-0
4 Su
rtem
p.ID
-48
N°
d'id
entif
. cla
vier
DR-
18 T
herm
ique
mot
eur
DR-
65 S
ortie
AN
A 4
2 [m
a]LG
-02
Jour
nal m
aint
en.:
heur
e
ID-0
5 Su
rten
sion
ID-4
9 N
°logi
c.ca
rte
ctrl.
DR-
22 C
oupl
e [%
]D
R-66
Sor
tie d
igita
le [b
in]
LG-0
3 Jo
urna
l mai
nten
.: da
te e
t he
ure
ID-0
6 Re
set
com
p. k
Wh
ID-5
0 N
°logi
c.ca
rte
puis
DR-
3# É
tat
varia
teur
DR-
67 F
réqu
. ent
rée
29 [H
z]LG
-1#
Jour
nal m
.ince
ndie
ID-0
7 Re
set
com
pt. h
eure
s de
fonc
tion.
ID-5
1 N
° sé
rie v
aria
teur
DR-
30 T
ensi
on D
C B
usD
R-68
Fré
qu. e
ntré
e 33
[Hz]
LG-1
0 Jo
urna
l mod
e in
cend
ie:
évén
emen
t
ID-0
8 N
b d
e dé
mar
rage
sID
-53
N°
série
car
te p
uiss
ance
DR-
32 P
uis.
Frei
n. /
sD
R-69
Sor
tie im
puls
ions
27
[Hz]
LG-1
1 Jo
urna
l mod
e in
cend
ie: h
eure
ID-1
# Ré
glag
es t
enda
nce
donn
ées
ID-6
# Id
entif
.Opt
ion
DR-
33 P
uis.
Frei
n. /
2 m
inD
R-70
Sor
tie im
puls
ions
29
[Hz]
LG-1
2 Jo
urna
l mod
e in
cend
ie: d
ate
ethe
ure
ID-1
0 So
urce
ten
danc
eID
-60
Opt
ion
mon
tée
DR-
34 T
emp.
rad
iate
urD
R-71
Sor
tie r
elai
s [b
in]
LG-3
# Ét
at o
ptio
n E
/S
ID-1
1 In
terv
alle
enr
.tend
.ID
-61
Vers
ion
logi
ciel
le o
ptio
nD
R-35
The
rmiq
ue v
aria
teur
DR-
72 C
ompt
eur
ALG
-30
Entr
ée A
NA
X42
/1
ID-1
2 Év
énem
ent
décl
ench
eur
ID-6
2 N
° co
de o
ptio
nD
R-36
Inom
var
iate
urD
R-73
Com
pteu
r B
LG-3
1 En
trée
AN
A X
42/3
ID-1
3 M
ode
tend
ance
ID-6
3 N
° sé
rie o
ptio
nD
R-37
Imax
var
iate
urD
R-75
Ent
rée
AN
A X
30/1
1LG
-32
Entr
ée A
NA
X42
/5
ID-1
4 Éc
hant
illon
s av
ant
décl
ench
emen
tID
-9#
Info
s pa
ram
ètre
DR-
38 É
tat
cont
rôle
ur lo
giqu
eD
R-76
Ent
rée
AN
A X
30/1
2LG
-33
Sort
ie A
NA
X42
/7 [V
]
ID-2
# Jo
urna
l his
toriq
ueID
-92
Para
mèt
res
défin
isD
R-39
Tem
p. c
arte
ctr
l.D
R-77
Sor
tie A
NA
X30
/8 [m
A]
LG-3
4 So
rtie
AN
A X
42/9
[V]
ID-2
0 Jo
urna
l his
toriq
ue: É
véne
men
tID
-93
Para
mèt
res
mod
ifiés
DR-
40 T
ampo
n e
nr.te
ndan
ce s
atur
éD
R-8#
Bus
et
port
var
iate
urLG
-35
Sort
ie A
NA
X42
/11
[V]
ID-2
1 Jo
urna
l his
toriq
ue: V
aleu
rD
R-##
Lec
ture
don
nées
DR-
43 T
imed
Act
ions
Sta
tus
DR-
80 M
ot c
trl.1
bus
AP-
## P
ar. a
ppl.
HVA
C
ID-2
2 Jo
urna
l his
toriq
ue: h
eure
DR-
0# É
tat
géné
ral
DR-
49 C
urre
nt F
ault
Sou
rce
DR-
82 R
éf.1
por
t bu
sA
P-0#
Div
ers
ID-2
3 Jo
urna
l his
toriq
ue: d
ate
et h
eure
DR-
00 M
ot c
ontr
ôle
DR-
5# R
éf.&
ret
our
DR-
84 Im
puls
ion
dém
arra
geA
P-00
Ret
ard
ver
roui
llage
ext
.
ID-3
# Jo
urna
l ala
rme
DR-
01 R
éf. [
unité
]D
R-50
Réf
.ext
erne
DR-
85 M
ot c
trl.1
por
t va
riate
urA
P-2#
Dét
ect.a
bs. d
ébit
ID-3
0 Jo
urna
l ala
rme
: cod
eD
R-02
Réf
. %D
R-52
Sig
nal d
e re
tour
[Uni
té]
DR-
86 R
éf.1
por
t va
riate
urA
P-20
Con
fig. a
uto
pui
ss.fa
ible
ID-3
1 Jo
urna
l ala
rme
: val
eur
DR-
03 M
ot d
'éta
tD
R-53
Réf
éren
ce p
ot. d
ig.
DR-
9# L
ect.
dia
gnos
ticA
P-21
Dét
ect.p
uiss
.faib
le
ID-3
2 Jo
urna
l ala
rme
: heu
reD
R-05
Val
eur
réel
le p
rinc.
[%]
DR-
54 R
etou
r 1
[Uni
té]
DR-
90 M
ot d
'ala
rme
AP-
22 D
étec
t. fr
éq. b
asse
ID-3
3 Jo
urna
l ala
rme
: dat
e et
heu
reD
R-09
Lec
t.par
amét
r.D
R-55
Ret
our
2 [U
nité
]D
R-91
Mot
d'a
larm
e 2
AP-
23 F
onct
. abs
déb
it
ID-4
# Ty
pe. V
AR.
DR-
1# É
tat
Mot
eur
DR-
56 R
etou
r 3
[Uni
té]
DR-
92 M
ot a
vert
is.
AP-
24 R
etar
d a
bs. d
ébit
ID-4
0 Ty
pe v
aria
teur
DR-
10 P
uiss
. mot
eur
[kW
]D
R-58
Sor
tie P
ID [%
]D
R-93
Mot
d'a
vert
isse
men
t 2
AP-
26 F
onct
.pom
pe à
sec
ID-4
1 Pa
rtie
pui
ss.
DR-
11 P
uiss
ance
mot
eur[
CV]
D
R-94
Mot
éta
t él
argi
AP-
27 R
etar
.pom
p.à
sec
Programmation Guide rapide de l'AF-600 FP
28 DET-759A/F
66
AP-
3# R
égl.p
uiss
.abs
déb
itA
P-71
Com
pres
sor
Star
t M
ax S
peed
[Hz]
FB-0
9 Tr
ait.a
larm
.mod
e in
cend
ieT-
14 D
ate
et h
eure
mai
nten
ance
CL-0
3 So
urce
ret
our
2
AP-
30 A
bsen
ce d
e dé
bit
AP-
72 C
ompr
esso
r St
art
Max
Tim
e to
Trip
FB-1
# Bi
pass
eT-
15 R
eset
mot
mai
nten
ance
CL-0
4 Co
nver
sion
ret
our
2
AP-
31 C
orre
ct. f
acte
ur p
uiss
.A
P-73
Sta
rtin
g A
ccel
erat
ion
Tim
eFB
-10
Fonc
t. b
ipas
se v
aria
teur
T-16
Tex
te m
aint
enan
ceCL
-05
Uni
té s
ourc
e re
tour
2
AP-
32 V
it. fa
ible
[tr/
min
]A
P-75
Pro
tec.
cou
rt-c
irc.
FB-1
1 Re
tard
bip
asse
var
iate
urT-
5# J
ourn
.éne
rgCL
-06
Sour
ce r
etou
r 3
AP-
33 V
it. fa
ible
[Hz]
AP-
76 T
ps e
ntre
2 d
émar
rage
sFB
-20
Lock
ed R
otor
Fun
ctio
nT-
50 R
ésol
utio
n e
nreg
istr
eur
d'én
ergi
eCL
-07
Conv
ersi
on re
tour
3
AP-
34 P
uiss
.vit.
faib
le [k
W]
AP-
77 T
ps d
e fc
t m
in.
FB-2
1 Lo
cked
Rot
or C
oeffi
cien
t 1
T-51
Dém
ar. p
ério
deCL
-08
Uni
té s
ourc
e re
tour
3
AP-
35 P
uiss
.vit.
faib
le [C
V]A
P-8#
Com
pens
at. d
ébit
FB-2
2 Lo
cked
Rot
or C
oeffi
cien
t 2
T-53
Jou
rn.é
nerg
CL-1
2 U
nité
réfé
renc
e/re
tour
AP-
36 V
it.él
evée
[tr/
min
]A
P-80
Com
pens
at. d
ébit
FB-2
3 Lo
cked
Rot
or C
oeffi
cien
t 3
T-54
Res
et jo
urn.
éner
gCL
-13
Réfé
renc
e m
inim
ale/
Reto
ur
AP-
37 V
it.él
evée
[Hz]
AP-
81 A
ppro
x. c
ourb
e lin
éaire
-qua
drat
ique
FB-2
4 Lo
cked
Rot
or C
oeffi
cien
t 4
T-6#
Ten
danc
eCL
-14
Réf.
max
./Ret
our
AP-
38 P
uiss
.vit.
élev
ée [k
W]
AP-
82 C
alcu
l pt
de tr
avai
lFB
-30
Mis
sing
Mot
or F
unct
ion
T-60
Var
iabl
.tend
.CL
-20
Fonc
tion
de
reto
ur
AP-
39 P
uiss
.vit.
élev
ée [C
V]A
P-83
Vit
abs
déb
it [t
r/m
in]
FB-3
1 M
issi
ng M
otor
Coe
ffici
ent
1T-
61 D
onné
es b
in. c
ontin
ues
CL-2
1 Co
nsig
ne 1
AP-
4# M
ode
veill
eA
P-84
Vit.
abs
. déb
it [H
z]FB
-32
Mis
sing
Mot
or C
oeffi
cien
t 2
T-62
Don
nées
bin
. tem
po.
CL-2
2 Co
nsig
ne 2
AP-
40 T
ps d
e fc
t m
in.
AP-
85 V
it p
t de
fonc
tionn
emen
t [t
r/m
in]
FB-3
3 M
issi
ng M
otor
Coe
ffici
ent
3T-
63 D
émar
r.pér
iod.
tem
poCL
-23
Cons
igne
3
AP-
41 T
ps d
e ve
ille
min
.A
P-86
Vit.
à p
t de
fonc
tionn
emen
t [H
z]FB
-34
Mis
sing
Mot
or C
oeffi
cien
t 4
T-64
Arr
êt p
ério
d.te
mpo
CL-3
# Co
nv. r
et. a
vanc
ée
AP-
42 V
it. ré
veil
[tr/
min
]A
P-87
Pre
ssio
n à
vit.
ss
débi
tT-
## F
onct
. tem
poris
ées
T-65
Val
eur
bin.
min
.CL
-30
Age
nt r
éfrig
éran
t
AP-
43 V
it. r
évei
l [H
z]A
P-88
Pre
ssio
n à
vit.
nom
inal
T-0#
Act
ions
tem
poT-
66 R
eset
don
nées
bin
.co
ntin
ues
CL-3
1 Ré
frig
éran
t dé
f. pa
r ut
ilis.
A1
AP-
44 D
iffér
ence
réf/
ret.
réve
ilA
P-89
Déb
it p
t de
fonc
tionn
emen
tT-
00 H
eure
act
iv.
T-67
Res
et d
onné
es b
in. t
empo
.CL
-32
Réfr
igér
ant
déf.
par
utili
s. A
2
AP-
45 C
onsi
gn.su
rpre
s.A
P-90
Déb
it à
vit.
nom
.T-
01 A
ctio
n a
ctiv
.T-
8# C
ompt
. réc
up.
CL-3
3 Ré
frig
éran
t dé
f. pa
r ut
ilis.
A3
AP-
46 T
ps s
urpr
essi
on m
ax.
FB-#
# Fc
t in
cend
ie/b
ipas
seT-
02 H
eure
arr
êtT-
80 F
acte
ur r
éf. d
e pu
iss.
CL-3
4 D
uct
1 A
rea
[m2]
AP-
5# F
in d
e co
urbe
FB-0
# M
ode
ince
ndie
T-03
Act
ion
arr
êtT-
81 C
oût
de l'
éner
gie
CL-3
5 D
uct
1 A
rea
[in2]
AP-
50 F
onct
ion
fin
cou
rbe
FB-0
0 Fo
nct.
mod
e in
cend
ieT-
04 T
x de
fréq
.T-
82 C
oût
CL-3
6 D
uct
2 A
rea
[m2]
AP-
51 R
etar
d fi
n c
ourb
eFB
-01
Conf
ig. m
ode
ince
ndie
T-08
Tim
ed A
ctio
ns M
ode
T-83
Éco
. d'é
nerg
ieCL
-37
Duc
t 2
Are
a [in
2]
AP-
6# D
étec
.cou
rroi
.cas
séFB
-02
Uni
té m
ode
ince
ndie
T-09
Tim
ed A
ctio
ns R
eact
ivat
ion
T-84
Éco
. d'é
chel
leCL
-38
Air
Den
sity
Fac
tor
[%]
AP-
60 F
onct
.cou
rroi
.cas
sée
FB-0
3 Ré
f. m
in. m
ode
ince
ndie
T-1#
Mai
nten
ance
CL-#
# PI
D b
oucl
e fe
rmée
CL-7
# Ré
gl. a
uto
PID
AP-
61 C
oupl
.cou
rroi
.cas
sée
FB-0
4 Ré
f. m
ax. m
ode
ince
ndie
T-10
Élé
men
t en
tret
enu
CL-0
# Re
tour
CL-7
0 Ty
pe b
oucl
e fe
rmée
AP-
62 R
etar
.cou
rroi
.cas
sée
FB-0
5 Ré
f. pr
édéf
. mod
e in
cend
ieT-
11 A
ctio
n d
e m
aint
en.
CL-0
0 So
urce
reto
ur 1
CL-7
1 M
ode
régl
age
AP-
7# P
rote
c. c
ourt
-circ
.FB
-06
Sour
ce ré
f. m
ode
ince
ndie
T-12
Bas
e tp
s m
aint
enan
ceCL
-01
Conv
ersi
on re
tour
1CL
-72
Mod
if. s
ortie
PID
AP-
70 C
ompr
esso
r St
art
Max
Spe
ed[R
PM]
FB-0
7 So
urce
reto
ur m
ode
ince
ndie
T-13
Tem
ps e
ntre
2 e
ntre
tiens
CL-0
2 U
nité
sou
rce
reto
ur 1
CL-7
3 N
ivea
u d
e re
tour
min
.
Programmation Guide rapide de l'AF-600 FP
DET-759A/F 29
6 6
CL-7
4 N
ivea
u d
e re
tour
max
.XC
-22
Tps
inté
gral
ext
. 1XC
-64
Lim
it.ga
in.D
ext
. 3PC
-52
Inte
rval
ent
re a
ltern
.LC
-43
Opé
rate
ur d
e Rè
gle
Logi
que
2
CL-7
9 Ré
gl. a
uto
PID
XC-2
3 Te
mps
de
dériv
ée e
xt. 1
PC-#
# Co
ntrô
leur
pom
pePC
-53
Vale
ur te
mpo
alte
rnan
ceLC
-44
Règl
e de
Log
ique
Boo
léen
ne 3
CL-8
# Ré
gl. b
asiq
. PID
XC-2
4 Li
mit.
gain
.D e
xt. 1
PC-0
# Ré
gl. s
ystè
me
PC-5
4 Tp
s pr
édéf
ini d
'alte
rnan
ceLC
-5#
État
s
CL-8
1 Co
ntrô
le n
orm
al/in
vers
é PI
DXC
-3#
Réf/
ret
PID
ét.
2PC
-00
Cont
rôle
ur p
ompe
PC-5
5 A
ltern
e si
cha
rge
< 5
0%LC
-51
Évén
emen
t co
ntr.
logi
que
CL-8
2 Vi
t.dém
. PID
[tr/
mn]
XC-3
0 U
nité
réf/
reto
ur e
xt. 2
PC-0
2 D
émar
. mot
.PC
-56
Mod
e dé
mar
r. su
r al
tern
ance
LC-5
2 A
ctio
n c
ontr
ôleu
r lo
giqu
e
CL-8
3 Vi
t.de
dém
. PID
[Hz]
XC-3
1 Ré
fére
nce
min
. ext
. 2PC
-04
Cycl
e po
mpe
PC-5
8 Re
tar.f
ct n
ouv.
pom
pB-
## F
onct
ions
de
frei
nage
CL-8
4 La
rgeu
r de
ban
de s
ur r
éf.
XC-3
2 Ré
fére
nce
max
. ext
. 2PC
-05
Pom
p.pr
inc
fixe
PC-5
9 Re
tard
fct
ligne
B-0#
Fre
inag
e
CL-9
# Co
ntrô
leur
du
PID
XC-3
3 So
urce
réfé
renc
e ex
t. 2
PC-0
6 N
b d
e po
mpe
sPC
-8#
État
B-00
I m
aint
ien
CC
CL-9
1 A
nti-s
atur
. PID
XC-3
4 So
urce
reto
ur e
xt. 2
PC-1
0 M
inim
um R
un T
ime
Ove
rrid
ePC
-80
État
pom
pes
B-01
Cou
rant
frei
n C
C
CL-9
3 G
ain
pro
port
ionn
el P
IDXC
-35
Cons
igne
ext
. 2
PC-1
1 M
inim
um R
un T
ime
Ove
rrid
e Va
lue
PC-8
1 Ét
at p
ompe
sB-
02 T
emps
frei
n C
C
CL-9
4 Tp
s in
tégr
al P
IDXC
-37
Réf.
ext.
2 [u
nité
]PC
-2#
Régl
. lar
g. b
ande
PC-8
2 Po
mp.
prin
c.B-
03 V
itess
e fr
ein
CC
[tr/
min
]
CL-9
5 Te
mps
de
dériv
ée d
u P
IDXC
-38
Reto
ur e
xt. 2
[uni
té]
PC-2
0 La
rg.b
ande
dém
ar.
PC-8
3 Ét
at r
elai
sB-
04 V
itess
e fr
ein
CC
[Hz]
CL-9
6 PI
D li
mit
gai
n D
XC-3
9 So
rtie
ext
. 2 [%
]PC
-21
Dép
ass.
larg
.ban
dePC
-84
Tps
fct
pom
peB-
1# F
onct
.Pui
s.Fre
in.
XC-#
# PI
D b
oucl
e fe
rmée
ét.
XC-4
# PI
D é
tend
u 2
PC-2
2 La
rg. b
ande
vit.
fixe
PC-8
5 Tp
s fc
t re
lais
B-10
Fon
ctio
n F
rein
et
Surt
ensi
on
XC-0
# Ré
glag
e au
to P
ID é
t.XC
-40
Cont
rôle
nor
mal
/inve
rse
ext
2PC
-23
Reta
rd d
émar
. SBW
PC-8
6 Re
set
com
pt. r
elai
sB-
16 C
oura
nt m
ax. f
rein
CA
XC-0
0 Ty
pe b
oucl
e fe
rmée
XC-4
1 G
ain
pro
port
ionn
el e
xt 2
PC-2
4 Re
tard
d'a
rrêt
SBW
PC-9
# Se
rvic
eB-
17 C
ontr
ôle
Surt
ensi
on
XC-0
1 M
ode
régl
age
XC-4
2 Tp
s in
tégr
al e
xt. 2
PC-2
5 Tp
s O
BWPC
-90
Verr
ouill
.pom
p
XC-0
2 M
odif.
sor
tie P
IDXC
-43
Tem
ps d
e dé
rivée
ext
. 2PC
-26
Arr
êt e
n a
bs. d
ébit
PC-9
1 A
ltern
ance
man
uel.
XC-0
3 N
ivea
u d
e re
tour
min
.XC
-44
Lim
it.ga
in.D
ext
. 2PC
-27
Fonc
t. dé
mar
r.LC
-##
Cont
rôle
ur lo
giqu
e
XC-0
4 N
ivea
u d
e re
tour
max
.XC
-5#
Réf/
ret
PID
ét.
3PC
-28
Dur
ée fo
nct.
dém
ar.
LC-0
# Ré
glag
es C
L
XC-0
9 Ré
gl. a
uto
PID
XC-5
0 U
nité
réf/
reto
ur e
xt. 3
PC-2
9 Fo
nctio
n d
'arr
êtLC
-00
Mod
e co
ntr.
logi
que
XC-1
# Ré
f/re
t PI
D é
t. 1
XC-5
1 Ré
fére
nce
min
. ext
. 3PC
-30
Dur
ée fo
nct.
d'a
rrêt
LC-0
1 Év
énem
ent
de d
émar
rage
XC-1
0 U
nité
réf/
reto
ur e
xt. 1
XC-5
2 Ré
fére
nce
max
. ext
. 3PC
-4#
Régl
ages
dém
arr.
LC-0
2 Év
énem
ent
d'ar
rêt
XC-1
1 Ré
fére
nce
min
. ext
. 1XC
-53
Sour
ce ré
fére
nce
ext.
3PC
-40
Reta
rd r
ampe
déc
él.
LC-0
3 Re
set
ctrle
ur lo
g.
XC-1
2 Ré
fére
nce
max
. ext
. 1XC
-54
Sour
ce re
tour
ext
. 3PC
-41
Reta
rd r
ampe
acc
él.
LC-1
# Co
mpa
rate
urs
XC-1
3 So
urce
réfé
renc
e ex
t. 1
XC-5
5 Co
nsig
ne e
xt. 3
PC-4
2 Se
uil d
e dé
mar
r.LC
-10
Opé
rand
e co
mpa
rate
ur
XC-1
4 So
urce
reto
ur e
xt. 1
XC-5
7 Ré
f. ex
t. 3
[uni
té]
PC-4
3 Se
uil d
'arr
êtLC
-11
Opé
rate
ur c
ompa
rate
ur
XC-1
5 Co
nsig
ne e
xt. 1
XC-5
8 Re
tour
ext
. 3 [u
nité
]PC
-44
Vit.
dém
ar. [
tr/m
in]
LC-1
2 Va
leur
com
para
teur
XC-1
7 Ré
f. ex
t. 1
[uni
té]
XC-5
9 So
rtie
ext
. 3 [%
]PC
-45
Vit.
dém
arr.
[Hz]
LC-2
# Te
mpo
risat
ions
XC-1
8 Re
tour
ext
. 1 [u
nité
]XC
-6#
PID
éte
ndu
3PC
-46
Vit.
d'ar
rêt
[tr/
min
]LC
-20
Tem
po.c
ontr
ôleu
r lo
giqu
e
XC-1
9 So
rtie
ext
. 1 [%
]XC
-60
Cont
rôle
nor
mal
/inve
rse
ext
3PC
-47
Vit.
d'a
rrêt
[Hz]
LC-4
# Rè
gles
de
Logi
que
XC-2
# PI
D é
tend
u 1
XC-6
1 G
ain
pro
port
ionn
el e
xt 3
PC-5
# Ré
gl. a
ltern
ance
LC-4
0 Rè
gle
de L
ogiq
ue B
oolé
enne
1
XC-2
0 Co
ntrô
le n
orm
al/in
vers
e ex
t1
XC-6
2 Tp
s in
tégr
al e
xt. 3
PC-5
0 A
ltern
.pom
pe p
rinc.
LC-4
1 O
péra
teur
de
Règl
e Lo
giqu
e 1
XC-2
1 G
ain
pro
port
ionn
el e
xt 1
XC-6
3 Te
mps
de
dériv
ée e
xt. 3
PC-5
1 Év
énem
ent
alte
rn.
LC-4
2 Rè
gle
de L
ogiq
ue B
oolé
enne
2
Programmation Guide rapide de l'AF-600 FP
30 DET-759A/F
66
6.2 Programmation à distance avec leDCT-10
GE propose un logiciel pour développer, stocker ettransférer la programmation du variateur. Le DCT-10permet à l'utilisateur de connecter un PC au variateur etde réaliser une programmation en direct au lieu d'utiliserle clavier. De même, toute la programmation duvariateurpeut être réalisée hors ligne puis simplementtéléchargée vers le variateur. Ou encore le profil entier duvariateur peut être chargé sur le PC à des fins desauvegarde ou d'analyse.
Le connecteur USB ou la borne RS-485 permet le raccor-dement au variateur.
Pour plus d'informations, consulter le site www.geelec-trical.com/drives.
Programmation Guide rapide de l'AF-600 FP
DET-759A/F 31
6 6
7 Avertissements et alarmes
7.1 Définitions des avertissements et des alarmes
Le Tableau 7.1 définit si un avertissement est émis avant une alarme ou si l'alarme arrête l'unité ou l'arrête avec unverrouillage.
N° Description Avertis-sement
Alarme/déclen-chement
Alarme/alarmeverrouillée
Référence du paramètre
1 10 V bas X
2 Déf zéro signal (X) (X) AN-01 Fonction/Tempo60
4 Perte phase secteur (X) (X) (X) SP-12 Fonct.sur désiqui.ligne
5 Tension DC bus élevée X
6 Tension CC bus basse X
7 Surtension CC X X
8 Sous-tension CC X X
9 Surcharge onduleur X X
10 Surtempérature Surcharge thermique
électronique moteur
(X) (X) F-10 Surcharge électronique
11 Surchauffe therm. mot. (X) (X) F-10 Surcharge électronique
12 Limite de couple X X
13 Surcourant X X X
14 Défaut de mise à la terre X X X
15 Incompatibilité matérielle X X
16 Court-circuit X X
17 Reset dépas. temps (X) (X) O-04 Mot de ctrl.Fonct.dépas.tps
18 Échec de démarrage
23 Panne de ventilateur interne X
24 Panne de ventilateur externe X SP-53 Surveillance ventilateur
29 Surchauffe variateur X X X
30 Phase U moteur absente (X) (X) (X) H-78 Surv. phase mot.
31 Phase V moteur absente (X) (X) (X) H-78 Surv. phase mot.
32 Phase W moteur absente (X) (X) (X) H-78 Surv. phase mot.
33 Erreur charge X X
34 Défaut com.bus X X
35 Erreur option X X
36 Défaut secteur X X
38 Erreur interne X X
39 Capteur radiatr X X
40 Surcharge borne sortie digitale 27 (X) E-00 Mode E/S digital, E-51 Mode born.
27
41 Surcharge borne sortie digitale 29 (X) E-00 Mode E/S digital, E-52 Mode born.
29
42 Surcharge sortie digitale sur X30/6 (X) E-56 S.digit.born. X30/6 (OPCGPIO)
42 Surcharge sortie digitale sur X30/7 (X) E-57 S.digit.born. X30/7 (OPCGPIO)
45 Défaut terre 2 45
46 Alim. carte puis. X X
47 Alim. 24 V bas X X X
48 Alim. 1,8 V bas X X
49 Limite Vit. X (X) H-36 Arrêt vit. basse [tr/min]
50 Étalonnage Réglage automatiqueéchoué
X
51 Réglage automatique U et I nom. X
Avertissements et alarmes Guide rapide de l'AF-600 FP
32 DET-759A/F
77
N° Description Avertis-sement
Alarme/déclen-chement
Alarme/alarmeverrouillée
Référence du paramètre
52 Réglage automatique Inom. bas X
53 Réglage automatique moteur gros X
54 Réglage automatique moteur petit X
55 Réglage automatique hors gam. X
56 Interrup. Réglage automatique X
57 Réglage automatique dépas. tps X
58 Réglage automatique déf. int. X X
59 Limite courant X
60 Verrouill. ext. X
62 Limite fréquence de sortie X
64 Limite tension X
65 Température excessive de la carte de
commande
X X X
66 Température radiateur basse X
67 Les options de configuration ontchangé
X
69 T° carte puis. X X
70 Config Variateur prohibé X
76 Config alim. X
79 ConfigPSprohib X X
80 Variateur initialisé à val. défaut X
91 Réglages incorrects entrée analogique54
X
92 Abs. de débit X X AP-2#
93 Pompe à sec X X AP-2#
94 Fin de courbe X X AP-5#
95 Courroie cassée X X AP-6#
96 Démar. retardé X AP-7#
97 Arrêt retardé X AP-7#
98 Déf.horloge X K-7#
201 M.inc. été act.
202 Lim.m.inc. dép.
203 Mot. manquant
204 Rotor verrouil.
243 Frein IGBT X X
244 Temp. radiateur X X X
245 Capteur radiatr X X
246 Alim. carte puis. X X
247 T° carte puis. X X
248 ConfigPSprohib X X
250 Nouvelles pièces X
251 Nouv. code type X X
Tableau 7.1 Liste des codes d'alarme/avertissement
(X) Dépendant du paramètre1) Ne peut pas être réinitialisé automatiquement via le par. H-04 Auto-reset (nb)
REMARQUE!Se reporter au Manuel d'utilisation de l'AF-600 FP pour une description détaillée et pour le dépannage.
Avertissements et alarmes Guide rapide de l'AF-600 FP
DET-759A/F 33
7 7
8 Spécifications
8.1 Caractéristiques techniques
Alimentation secteur (L1, L2, L3) :Tension d'alimentation 200-240 V ±10 %, 380-480 V ±10 %, 525-600 V ±10 %, 525-690 V ±10 %
Tension secteur faible/chute de tension secteur :En cas de tension secteur basse ou de chute de la tension secteur, le variateur continue de fonctionner jusqu'à ce que la tensionprésente sur le circuit intermédiaire descende sous le seuil d'arrêt minimum, qui correspond généralement à moins de 15 % de latension nominale d'alimentation secteur du variateur. Mise sous tension et couple complet ne sont pas envisageables à unetension secteur inférieure à 10 % de la tension nominale d'alimentation secteur du variateur.
Fréquence d'alimentation 50/60 Hz ±5 %Écart temporaire max. entre phases secteur 3,0 % de la tension nominale d'alimentationFacteur de puissance réelle () ≥ 0,9 à charge nominaleFacteur de puissance de déphasage (cos) proche de l'unité (> 0,98)Commutation sur l'entrée d'alimentation L1, L2, L3 (hausses de puissance) ≤ 7,5 kW/10 HP et moins maximum 2 fois/minCommutation sur l'entrée d'alimentation L1, L2, L3 (hausses de puissance) ≥ 7,5 kW/10 HP et moins maximum 1 fois/minCommutation sur l'entrée d'alimentation L1, L2, L3 (hausses de puissance) ≥ 110 kW/150 HP et plus maximum 1 fois/2 minEnvironnement conforme à la norme EN 60664-1 catégorie de surtension III/degré de pollution 2
L'utilisation de l'unité convient sur un circuit limité à 100 000 ampères symétriques (rms), 240/480/600 V maximum.
Puissance du moteur (U, V, W) :Tension de sortie 0 à 100 % de la tension d'alimentationFréquence de sortie (0,25-75 kW)/(75 kW/125 HP) 0-1000 HzFréquence de sortie (90-1000 kW)/(90 kW/150 HP) 0-8001) HzFréquence de sortie en mode Flux 0-300 HzCommutation sur la sortie IllimitéeTemps de rampe 0,01-3600 s
1) Dépend de la tension et de la puissance
Caractéristiques de couple :Couple de démarrage (couple constant) maximum 160 % pendant 60 s1)
Couple de démarrage maximum 180 % jusqu'à 0,5 s1)
Surcouple (couple constant) maximum 160 % pendant 60 s1)
Couple de démarrage (couple variable) maximum 110 % pendant 60 s1)
Surcouple (couple variable) maximum 110 % pendant 60 s
Temps de montée du couple en (indépendant de fsw) 10 msTemps de montée du couple en contrôle vectoriel du flux (pour fsw égale à 5 kHz) 1 ms
1) Le pourcentage est calculé par rapport au couple nominal.2) Le temps de réponse du couple dépend de l'application et de la charge, mais en général, le temps de passage du couple de 0 àla valeur de référence est égal à 4-5 x le temps de montée du couple.
Longueurs et sections de câble :Longueur max. du câble moteur, blindé/armé 150 mLongueur max. du câble moteur, non blindé/non armé 300 mSection max. des bornes de commande, fil rigide 1,5 mm2/16 AWG (2 x 0,75 mm2)Section max. des bornes de commande, fil souple 1 mm2/18 AWGSection max. des bornes de commande, fil avec noyau blindé 0,5 mm2/20 AWGSection minimale des bornes de commande 0,25 mm2
Spécifications Guide rapide de l'AF-600 FP
34 DET-759A/F
88
Entrées digitales :Entrées digitales programmables 4 (6)1)
N° de borne 18, 19, 271), 291), 32, 33,Logique PNP ou NPNNiveau de tension 0-24 V CCNiveau de tension, "0" logique PNP < 5 V CCNiveau de tension, "1" logique PNP > 10 V CCNiveau de tension, "0" logique NPN2) > 19 V CCNiveau de tension, "1" logique NPN2) < 14 V CCTension maximale sur l'entrée 28 V CCPlage de fréquence impulsionnelle 0-110 kHz(Cycle d'utilisation) durée impulsionnelle min. 4,5 msRésistance d'entrée, Ri env. 4 kΩEntrées analogiques :Nombre d'entrées analogiques 2N° de borne 53, 54Modes Tension ou courantSélection du mode Commutateurs S201 et S202Mode tension Commutateur S201/commutateur S202 = Inactif (U)Niveau de tension -10 à +10 V (échelonnable)Résistance d'entrée, Ri env. 10 kΩTension max. ±20 VMode courant Commutateur S201/commutateur S202 = Actif (I)Niveau de courant 0/4 à 20 mA (échelonnable)Résistance d'entrée, Ri env. 200 ΩCourant max. 30 mARésolution des entrées analogiques 10 bits (+ signe)Précision des entrées analogiques Erreur max. 0,5 % de l'échelle totaleLargeur de bande 100 Hz
Les entrées analogiques sont isolées galvaniquement de la tension d'alimentation (PELV) et d'autres bornes haute tension.
Entrées codeur/impulsions :Entrées codeur/impulsions programmables 2/1Numéro de borne impulsion/codeur 29, 331) / 322), 332)
Fréquence max. à la borne 29, 32, 33 110 kHz (activation push-pull)Fréquence max. à la borne 29, 32, 33 5 kHz (collecteur ouvert)Fréquence min. à la borne 29, 32, 33 4 HzNiveau de tension Voir la section concernant l'entrée digitaleTension maximale sur l'entrée 28 V CCRésistance d'entrée, Ri env. 4 kΩPrécision d'entrée d'impulsion (0,1-1 kHz) Erreur max. : 0,1 % de l'échelle totalePrécision d'entrée du codeur (1-11 kHz) Erreur max. : 0,05 % de l'échelle totale
Les entrées impulsionnelles et du codeur (bornes 29, 32, 33) sont isolées de façon galvanique de la tension d'alimentation (PELV)et d'autres bornes haute tension.1) Les entrées impulsionnelles sont 29 et 332) Entrées codeur : 32 = A et 33 = B
Spécifications Guide rapide de l'AF-600 FP
DET-759A/F 35
8 8
Sortie analogique :Nombre de sorties analogiques programmables 1N° de borne 42Plage de courant à la sortie analogique 0/4-20 mACharge max. à la terre - sortie analogique 500 ΩPrécision de la sortie analogique Erreur max. : 0,5 % de l'échelle totaleRésolution de la sortie analogique 12 bits
La sortie analogique est isolée galvaniquement de la tension secteur (PELV) et d'autres bornes haute tension.
Carte de commande, communication série RS-485 :N° de borne 68 (P, TX+, RX+), 69 (N, TX-, RX-)Borne n° 61 Commune aux bornes 68 et 69
Le circuit de communication série RS-485 est séparé fonctionnellement des autres circuits centraux et isolé galvaniquement de latension d'alimentation (PELV).
Sortie digitale :Sorties digitales/impulsions programmables 2N° de borne 27, 29 1)
Niveau de tension à la sortie digitale/en fréquence 0-24 VCourant de sortie max. (récepteur ou source) 40 mACharge max. à la sortie en fréquence 1 kΩCharge capacitive max. à la sortie en fréquence 10 nFFréquence de sortie min. à la sortie en fréquence 0 HzFréquence de sortie max. à la sortie en fréquence 32 kHzPrécision de la sortie en fréquence Erreur max. : 0,1 % de l'échelle totaleRésolution des sorties en fréquence 12 bits
1) Les bornes 27 et 29 peuvent être programmées comme entrée.
La sortie digitale est isolée galvaniquement de la tension d'alimentation (PELV) et d'autres bornes haute tension.
Carte de commande, sortie 24 V CC :N° de borne 12, 13Tension de sortie 24 V +1, -3 VCharge max. 200 mA
L'alimentation 24 V CC est isolée galvaniquement de la tension secteur (PELV) tout en ayant le même potentiel que les entrées etsorties analogiques et digitales.
Spécifications Guide rapide de l'AF-600 FP
36 DET-759A/F
88
Sorties de relais :Sorties de relais programmables 2 en forme de CN° de borne relais 01 1-3 (interruption), 1-2 (établissement)Charge max. sur les bornes (CA-1)1) sur 1-3 (NF), 1-2 (NO) (charge résistive) 240 V CA, 2 ACharge max. sur les bornes (CA-15)1) (charge inductive à cosφ 0,4) 240 V CA, 0,2 ACharge max. sur les bornes (CC-1)1) sur 1-2 (NO), 1-3 (NF) (charge résistive) 60 V CC, 1 ACharge max. sur les bornes (CC-13)1) (charge inductive) 24 V CC, 0,1 AN° de borne relais 02 4-6 (interruption), 4-5 (établissement)Charge max. sur les bornes (CA-1)1) sur 4-5 (NO) (charge résistive)2)3) Surtension cat. II 400 V CA, 2 ACharge max. sur les bornes (CA-15)1) sur 4-5 (NO) (charge inductive à cosφ 0,4) 240 V CA, 0,2 ACharge max. sur les bornes (CC-1)1) sur 4-5 (NO) (charge résistive) 80 V CC, 2 ACharge max. sur les bornes (CC-13)1) sur 4-5 (NO) (charge inductive) 24 V CC, 0,1 ACharge max. sur les bornes (CA-1)1) sur 4-6 (NF) (charge résistive) 240 V CA, 2 ACharge max. sur les bornes (CA-15)1) sur 4-6 (NF) (charge inductive à cosφ 0,4) 240 V CA, 0,2 ACharge max. sur les bornes (CC-1)1) sur 4-6 (NF) (charge résistive) 50 V CC, 2 ACharge max. sur les bornes (CC-13)1) sur 4-6 (NF) (charge inductive) 24 V CC, 0,1 ACharge min. sur les bornes 1-3 (NF), 1-2 (NO), 4-6 (NF), 4-5 (NO) 24 V CC 10 mA, 24 V CA 20 mAEnvironnement conforme à la norme EN 60664-1 catégorie de surtension III/degré de pollution 2
1) CEI 60947 parties 4 et 5Les contacts de relais sont isolés galvaniquement du reste du circuit par une isolation renforcée (PELV).2) Catégorie de surtension II3) Applications UL 300 V CA, 2 A
Carte de commande, sortie 10 V CC :N° de borne 50Tension de sortie 10,5 V ±0,5 VCharge max. 15 mA
L'alimentation 10 V CC est isolée galvaniquement de la tension secteur (PELV) et d'autres bornes haute tension.
Caractéristiques de contrôle :Résolution de fréquence de sortie à 0-1000 Hz ±0,003 HzPrécision de reproductibilité de Dém/arrêt précis (bornes 18, 19) ≤±0,1 msTemps de réponse système (bornes 18, 19, 27, 29, 32, 33) ≤ 2 msVitesse, plage de régulation (boucle ouverte) 1:100 de la vitesse synchronePlage de commande de vitesse (boucle fermée) 1:1000 de la vitesse synchroneVitesse, précision (boucle ouverte) 30-4000 tr/min : erreur de ±8 tr/minPrécision de vitesse (boucle fermée) fonction de la résolution du dispositif du signalde retour 0-6000 tr/min : erreur de ±0,15 tr/minPrécision de commande du couple (retour de vitesse) erreur max. ±5% du couple nominal
Toutes les caractéristiques de contrôle sont basées sur un moteur asynchrone 4 pôles.
Environnement :Essai de vibration, tout type de protection 1,0 gHumidité relative 5 %-95 % (CEI 721-3-3) ; classe 3K3 (non condensante) pendant le fonctionnementEnvironnement agressif (CEI 60068-2-43) test H2S classe KdMéthode d'essai conforme à CEI 60068-2-43 H2S (10 jours)Température ambiante (en mode de commutation 60 AVM)- avec déclassement max. 50 °C1)
- avec puissance de sortie totale des moteurs EFF2 typiques (jusqu'à 90 % du courant de sortie) max. 50 °C1)
- avec courant de sortie du variateur continu max. max. 45 °C1)
1) Pour plus d'informations sur le déclassement, voir le Manuel de configuration de l'AF-600 FP au chapitre Conditions spéciales.
Température ambiante min. en pleine exploitation 0°CTempérature ambiante min. en exploitation réduite - 10 °CTempérature durant le stockage/transport -25 - +65/70 °CAltitude max. au-dessus du niveau de la mer sans déclassement 1000 m
Spécifications Guide rapide de l'AF-600 FP
DET-759A/F 37
8 8
Altitude max. au-dessus du niveau de la mer avec déclassement 3000 m
Déclassement pour haute altitude, voir le chapitre concernant les conditions spéciales
Normes CEM, Émission EN 61800-3, EN 61000-6-3/4, EN 55011, CEI 61800-3
Normes CEM, ImmunitéEN 61800-3, EN 61000-6-1/2,
EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6Fonctionnement de la carte de commande :Intervalle de balayage 1 msCarte de commande, communication série USB :Norme USB 1.1 (Full speed)Fiche USB Fiche "appareil" USB de type B
La connexion au PC est réalisée via un câble USB standard hôte/dispositif.La connexion USB est isolée de façon galvanique de la tension d'alimentation (PELV) et d'autres bornes sous haute tension.La mise à la terre USB n'est pas isolée de façon galvanique de la terre de protection. Utiliser uniquement un ordinateur portableisolé en tant que connexion PC au connecteur USB sur le variateur.
Protection et caractéristiques :
• Protection du moteur thermique électronique contre les surcharges
• La surveillance de la température du radiateur assure l'arrêt du variateur lorsque la température atteint un niveauprédéfini. Le reset d'une surtempérature n'est possible que lorsque la température du radiateur est inférieure auxvaleurs mentionnées dans les tableaux des pages suivantes (remarque : ces températures peuvent varier enfonction de la puissance, des tailles d'unité, des niveaux de protection, etc.).
• Le variateur est protégé contre les courts-circuits aux bornes U, V, W du moteur.
• En cas d'absence de l'une des phases secteur, le variateur s'arrête ou émet un avertissement (en fonction de lacharge).
• Le contrôle de la tension du circuit intermédiaire garantit l'arrêt du variateur si la tension du circuit intermédiaireest trop basse ou trop élevée.
• Le variateur contrôle en permanence les niveaux critiques de température interne, courant de charge, hautetension sur le circuit intermédiaire et les vitesses faibles du moteur. Pour répondre à un niveau critique, levariateur peut ajuster la fréquence de commutation ou changer le type de modulation pour garantir laperformance du variateur.
Spécifications Guide rapide de l'AF-600 FP
38 DET-759A/F
88
8.2.1 Fusibles
Il est recommandé d'utiliser des fusibles et/ou des disjoncteurs du côté de l'alimentation comme protection en cas depanne d'un composant interne au variateur (première panne).
REMARQUE!Ceci est obligatoire pour assurer la conformité à la norme CEI 60364 pour la conformité CE et au NEC 2009 pour laconformité UL.
AVERTISSEMENTLe personnel et les biens doivent être protégés contre les conséquences éventuelles d'une panne de composant interne auvariateur.
Protection du circuit de dérivationAfin de protéger l'installation contre les risques électriques et d'incendie, tous les circuits de dérivation d'une installation,d'un appareillage de connexion, de machines, etc. doivent être protégés contre les courts-circuits et les surcourants, confor-mément aux règlements nationaux et internationaux.
REMARQUE!Pour UL, les recommandations données ne traitent pas la protection du circuit de dérivation.
Protection contre les courts-circuits :GE recommande d'utiliser les fusibles/disjoncteurs mentionnés ci-dessous afin de protéger le personnel d'entretien et l'équi-pement en cas de panne d'un composant interne au variateur.
Protection contre les surcourants :Le variateur offre une protection contre les surcharges afin de limiter les risques personnels, les dommages matériels et lesrisques d'incendie dus à la surchauffe des câbles dans l'installation. Le variateur est équipé d'une protection interne contreles surcourants (F-43 Limite de courant) qui peut être utilisée comme une protection de surcharge en amont (applications ULexclues). Des fusibles ou des disjoncteurs peuvent être utilisés en sus pour fournir la protection de surcourant dans l'instal-lation. Une protection de surcourant doit toujours être exécutée selon les règlements nationaux.
AVERTISSEMENTLe non-respect des recommandations peut entraîner des risques pour le personnel et endommager le variateur et d'autreséquipements en cas de dysfonctionnement.
Les tableaux suivants donnent la liste des courants nominaux recommandés. Les fusibles de type gG sont recommandéspour des puissances faibles à moyennes. Pour des puissances plus élevées, les fusibles aR sont recommandés. Il faut utiliserdes disjoncteurs à condition qu'ils répondent aux réglementations nationales/internationales et que leur énergie dans levariateur se limite à une valeur inférieure ou égale à celle des disjoncteurs conformes.Si des fusibles/disjoncteurs conformes aux recommandations sont utilisés, les dommages éventuels au variateur se limiterontprincipalement à des dommages internes à l'unité.
8.2.2 Conformité CE
Les fusibles et les disjoncteurs doivent obligatoirement être conformes à la norme CEI 60364. GE recommande l'utilisationde la sélection suivante :
L'utilisation des fusibles ci-dessous convient sur un circuit capable de délivrer 100 000 Arms (symétriques), 240 V, 480 V, 500V ou 600 V en fonction de la tension nominale du variateur. Avec des fusibles adaptés, le courant nominal de court-circuitdu variateur (SCCR) s'élève à 100 000 Arms.
Spécifications Guide rapide de l'AF-600 FP
DET-759A/F 39
8 8
AF-600 triphasé Taille de fusible recommandée Taille de fusible max. recommandée
[kW]/[HP]
0,75/1
gG-16 gG-251,5/2
2,2/3
3,7/5 gG-20 gG-32
5,5/7,5
gG-50 gG-637,5/10
11 / 15
15 / 20gG-80 gG-125
18,5/25
22 / 30 gG-125 gG-150
30 / 40 aR-160 aR-160
37 / 50 aR-200 aR-200
45 / 60 aR-250 aR-250
Tableau 8.1 200-240 V, IP20/châssis ouvert
AF-600 triphasé Taille de fusible recommandée Taille de fusible max. recommandée
[kW]/[HP]
0,75/1
gG-20 gG-321,5/2
2,2/3
3,7/5
5,5/7,5
gG-63 gG-807,5/10
11 / 15
15 / 20 gG-80 gG-100
18,5/25gG-125 gG-160
22 / 30
30 / 40 aR-160 aR-160
37 / 50 aR-200 aR-200
45 / 60 aR-250 aR-250
Tableau 8.2 IP55/Nema 12 et IP66/Nema 4X, utilisation en intérieur
Spécifications Guide rapide de l'AF-600 FP
40 DET-759A/F
88
AF-600 triphasé Taille de fusible recommandée Taille de fusible max. recommandée
[kW]/[HP]
0,75/1
gG-16 gG-251,5/2
2,2/3
3,7/5
5,5/7,5gG-20 gG-32
7,5/10
11 / 15
gG-50 gG-6315 / 20
18,5/25
22 / 30
gG-80 gG-12530 / 40
37 / 50
45 / 60 gG-125 gG-150
55 / 75 aR-160 aR-160
75 / 100aR-250 aR-250
90 / 125
110 / 150 gG-300 gG-300
132 / 200 gG-350 gG-350
160 / 250 gG-400 gG-400
200 / 300 gG-500 gG-500
250 / 350 gG-630 gG-630
315 / 450 aR-700 aR-700
355 / 500
aR-900 aR-900400 / 550
450 / 600
500 / 650aR-1600 aR-1600
560 / 750
630 / 900aR-2000 aR-2000
710 / 1000
800 / 1200aR-2500 aR-2500
1000 / 1350
Tableau 8.3 380-480 V, IP20/châssis ouvert
Spécifications Guide rapide de l'AF-600 FP
DET-759A/F 41
8 8
AF-600 triphasé Taille de fusible recommandée Taille de fusible max. recommandée
[kW]/[HP]
0,75/1 gG-20 gG-32
1,5/2
2,2/3
3,7/5
5,5/7,5
7,5/10
11 / 15 gG-50 gG-80
15 / 20
18,5/25
22 / 30 gG-80 gG-100
30 / 40
37 / 50 gG-125 gG-160
45 / 60
55 / 75
75 / 100 aR-250 aR-250
90 / 125
110 / 150 gG-300 gG-300
132 / 200 gG-350 gG-350
160 / 250 gG-400 gG-400
200 / 300 gG-500 gG-500
250 / 350 gG-630 gG-630
315 / 450 aR-700 aR-700
355 / 500
aR-900 aR-900400 / 550
450 / 600
500 / 650aR-1600 aR-1600
560 / 750
630 / 900aR-2000 aR-2000
710 / 1000
800 / 1200aR-2500 aR-2500
1000 / 1350
Tableau 8.4 380-480 V, IP55/Nema 12
Spécifications Guide rapide de l'AF-600 FP
42 DET-759A/F
88
AF-600 triphasé Taille de fusible recommandée Taille de fusible max. recommandée
[kW]/[HP]
0,75/1
gG-10 gG-251,5/2
2,2/3
3,7/5
5,5/7,5gG-16 gG-32
7,5/10
11 / 15
gG-35 gG-6315 / 20
18,5/25
22 / 30
gG-63 gG-12530 / 40
37 / 50
45 / 60gG-100 gG-150
55 / 75
75 / 100aR-250 aR-250
90 / 125
Tableau 8.5 525-600 V, IP20/châssis ouvert
AF-600 triphasé Taille de fusible recommandée Taille de fusible max. recommandée
[kW]/[HP]
0,75/1
gG-16 gG-32
1,5/2
2,2/3
3,7/5
5,5/7,5
7,5/10
11 / 15
gG-35 gG-8015 / 20
18,5/25
22 / 30gG-50 gG-100
30 / 40
37 / 50gG-125 gG-160
45 / 60
55 / 75
aR-250 aR-25075 / 100
90 / 125
Tableau 8.6 525-600 V, IP55/Nema 12
Spécifications Guide rapide de l'AF-600 FP
DET-759A/F 43
8 8
AF-600 triphasé Taille de fusible recommandéeTaille de fusible max.
recommandée
[kW]/[HP]
11/15 gG-25
gG-6315/20
gG-3218.5/25
22/30 gG-40
30/40gG-63
gG-80
37/50 gG-100
45/60 gG-80 gG-125
55/75 gG-100
gG-16075/100gG-125
90/125
110/150 aR-250 aR-250
132/200 aR-315 aR-315
160/250aR-350 aR-350
200/300
250/350 aR-400 aR-400
315/450 aR-500 aR-500
400/550 aR-550 aR-550
450/600aR-700 aR-700
500/650
560/750aR-900 aR-900
630/900
710/1000
aR-1600 aR-1600800/1150
900/1250
1000/1350
1200/1600 aR-2000 aR-2000
1400/1900 aR-2500 aR-2500
Tableau 8.7 525-690 V, IP21/Nema 1 and IP55/Nema 12
Spécifications Guide rapide de l'AF-600 FP
44 DET-759A/F
88
8.2.3 Conformité UL et NEC
Les fusibles et les disjoncteurs doivent obligatoirement être conformes au NEC 2009. Il est recommandé d'utiliser descomposants appartenant à la liste ci-dessous.
L'utilisation des fusibles ci-dessous convient sur un circuit capable de délivrer 100 000 Arms (symétriques), 240 V, 480 V, ou600 V en fonction de la tension nominale du variateur. Avec des fusibles adaptés, le courant nominal de court-circuit duvariateur (SCCR) s'élève à 100 000 Arms.
Taille de fusible max. recommandée
AF-600monopha
sé
AF-600triphasé Bussmann Bussmann Bussmann Bussmann Bussmann Bussmann
[kW]/[HP] [kW]/[HP] Type RK1 1) Type J Type T Type CC Type CC Type CC
0,75/1 KTN-R-10 JKS-10 JJN-10 FNQ-R-10 KTK-R-10 LP-CC-10
1,5/2 KTN-R-15 JKS-15 JJN-15 FNQ-R-15 KTK-R-15 LP-CC-15
1,5/2 2,2/3 KTN-R-20 JKS-20 JJN-20 FNQ-R-20 KTK-R-20 LP-CC-20
2,2/3 3,7/5 KTN-R-30 JKS-30 JJN-30 FNQ-R-30 KTK-R-30 LP-CC-30
3,7/5 5,5-7,5/7,5-10
KTN-R-50 KS-50 JJN-50 - - -
5,5/7,5 11 / 15 KTN-R-60 JKS-60 JJN-60 - - -
7,5/10 15 / 20 KTN-R-80 JKS-80 JJN-80 - - -
18,5-22/25-30
KTN-R-125 JKS-125 JJN-125 - - -
15 / 20 30 / 40 KTN-R-150 JKS-150 JJN-150 - - -
23 / 30 37 / 50 KTN-R-200 JKS-200 JJN-200 - - -
45 / 60 KTN-R-250 JKS-250 JJN-250 - - -
Tableau 8.8 200-240V
Taille de fusible max. recommandée
AF-600monopha
sé
AF-600triphasé SIBA Littel fuse
Ferraz-Shawmut
Ferraz-Shawmut
[kW]/[HP] [kW]/[HP] Type RK1 Type RK1 Type CC Type RK13)
0,75/1 5017906-010 KLN-R-10 ATM-R-10 A2K-10-R
1,5/2 5017906-016 KLN-R-15 ATM-R-15 A2K-15-R
1,5/2 2,2/3 5017906-020 KLN-R-20 ATM-R-20 A2K-20-R
2,2/3 3,7/5 5012406-032 KLN-R-30 ATM-R-30 A2K-30-R
3,7/5 5,5-7,5/7,5-10
5014006-050 KLN-R-50 - A2K-50-R
5,5/7,5 11 / 15 5014006-063 KLN-R-60 - A2K-60-R
7,5/10 15 / 20 5014006-080 KLN-R-80 - A2K-80-R
18,5-22/25-30
2028220-125 KLN-R-125 - A2K-125-R
15 / 20 30 / 40 2028220-150 KLN-R-150 - A2K-150-R
23 / 30 37 / 50 2028220-200 KLN-R-200 - A2K-200-R
45 / 60 2028220-250 KLN-R-250 - A2K-250-R
Tableau 8.9 200-240V
Spécifications Guide rapide de l'AF-600 FP
DET-759A/F 45
8 8
Taille de fusible max. recommandée
AF-600monopha
sé
AF-600triphasé Bussmann Littel fuse
Ferraz-Shawmut
Ferraz-Shawmut
[kW]/[HP] [kW]/[HP] Type JFHR22) Type JFHR2 Type JFHR24) Type J
0,75/1 FWX-10 - - HSJ-10
1,5/2 FWX-15 - - HSJ-15
1,5/2 2,2/3 FWX-20 - - HSJ-20
2,2/3 3,7/5 FWX-30 - - HSJ-30
3,7/5 5,5-7,5/7,5-10
FWX-50 - - HSJ-50
5,5/7,5 11 / 15 FWX-60 - - HSJ-60
7,5/10 15 / 20 FWX-80 - - HSJ-80
18,5-22/2
5-30
FWX-125 - - HSJ-125
15 / 20 30 / 40 FWX-150 L25S-150 A25X-150 HSJ-150
23 / 30 37 / 50 FWX-200 L25S-200 A25X-200 HSJ-200
45 / 60 FWX-250 L25S-250 A25X-250 HSJ-250
Tableau 8.10 200-240V
1) Les fusibles KTS de Bussmann peuvent remplacer les fusibles KTN pour les variateurs de fréquence 240 V.
2) Les fusibles FWH de Bussmann peuvent remplacer les fusibles FWX pour les variateurs de fréquence de 240 V.
3) Les fusibles A6KR de FERRAZ SHAWMUT peuvent remplacer les fusibles A2KR pour les variateurs de fréquence240 V.
4) Les fusibles A50X de FERRAZ SHAWMUT peuvent remplacer les fusibles A25X pour les variateurs de fréquence240 V.
Taille de fusible max. recommandée
AF-600monophasé
AF-600triphasé
Bussmann Bussmann Bussmann Bussmann Bussmann Bussmann
[kW]/[HP] [kW]/[HP]
Type RK1 Type J Type T Type CC Type CC Type CC
0,75/1 KTS-R-6 JKS-6 JJS-6 FNQ-R-6 KTK-R-6 LP-CC-6
1,5-2,2/2-3
KTS-R-10 JKS-10 JJS-10 FNQ-R-10 KTK-R-10 LP-CC-10
3,7/5 KTS-R-20 JKS-20 JJS-20 FNQ-R-20 KTK-R-20 LP-CC-20
5,5/7,5 KTS-R-25 JKS-25 JJS-25 FNQ-R-25 KTK-R-25 LP-CC-25
7,5/10 KTS-R-30 JKS-30 JJS-30 FNQ-R-30 KTK-R-30 LP-CC-30
11-15 /15-20
KTS-R-40 JKS-40 JJS-40 - - -
18,5/25 KTS-R-50 JKS-50 JJS-50 - - -
7,5/10 22 / 30 KTS-R-60 JKS-60 JJS-60 - - -
11 / 15 30 / 40 KTS-R-80 JKS-80 JJS-80 - - -
37 / 50 KTS-R-100 JKS-100 JJS-100 - - -
45 / 60 KTS-R-125 JKS-125 JJS-125 - - -
18,5/25 55 / 75 KTS-R-150 JKS-150 JJS-150 - - -
37 / 50 75 / 100 KTS-R-200 JKS-200 JJS-200 - - -
90 / 125 KTS-R-250 JKS-250 JJS-250 - - -
Tableau 8.11 380-480 V, 125 HP et inférieur
Spécifications Guide rapide de l'AF-600 FP
46 DET-759A/F
88
Taille de fusible max. recommandée
AF-600monophasé
AF-600 triphasé SIBA Littel fuseFerraz-
ShawmutFerraz-
Shawmut
[kW]/[HP] [kW]/[HP] Type RK1 Type RK1 Type CC Type RK1
0,75/1 5017906-006 KLS-R-6 ATM-R-6 A6K-10-6
1,5-2,2/2-3 5017906-010 KLS-R-10 ATM-R-10 A6K-10-R
3,7/5 5017906-020 KLS-R-20 ATM-R-20 A6K-20-R
5,5/7,5 5017906-025 KLS-R-25 ATM-R-25 A6K-25-R
7,5/10 5012406-032 KLS-R-30 ATM-R-30 A6K-30-R
11-15 / 15-20 5014006-040 KLS-R-40 - A6K-40-R
18,5/25 5014006-050 KLS-R-50 - A6K-50-R
7,5/10 22 / 30 5014006-063 KLS-R-60 - A6K-60-R
11 / 15 30 / 40 2028220-100 KLS-R-80 - A6K-80-R
37 / 50 2028220-125 KLS-R-100 - A6K-100-R
45 / 60 2028220-125 KLS-R-125 - A6K-125-R
18,5/25 55 / 75 2028220-160 KLS-R-150 - A6K-150-R
37 / 50 75 / 100 2028220-200 KLS-R-200 - A6K-200-R
90 / 125 2028220-250 KLS-R-250 - A6K-250-R
Tableau 8.12 380-480 V, 125 HP et inférieur
Taille de fusible max. recommandée
AF-600monophasé
AF-600 triphasé Bussmann Ferraz-Shawmut Ferraz-Shawmut Littel fuse
[kW]/[HP] [kW]/[HP] Type JFHR2 Type J Type JFHR21) Type JFHR2
0,75/1 FWH-6 HSJ-6 - -
1,5-2,2/2-3 FWH-10 HSJ-10 - -
3,7/5 FWH-20 HSJ-20 - -
5,5/7,5 FWH-25 HSJ-25 - -
7,5/10 FWH-30 HSJ-30 - -
11-15 / 15-20 FWH-40 HSJ-40 - -
18,5/25 FWH-50 HSJ-50 - -
7,5/10 22 / 30 FWH-60 HSJ-60 - -
11 / 15 30 / 40 FWH-80 HSJ-80 - -
37 / 50 FWH-100 HSJ-100 - -
45 / 60 FWH-125 HSJ-125 - -
18,5/25 55 / 75 FWH-150 HSJ-150 - -
37 / 50 75 / 100 FWH-200 HSJ-200 A50-P-225 L50-S-225
90 / 125 FWH-250 HSJ-250 A50-P-250 L50-S-250
Tableau 8.13 380-480 V, 125 HP et inférieur
1) Les fusibles A50QS de Ferraz-Shawmut peuvent remplacer les fusibles A50P.
Spécifications Guide rapide de l'AF-600 FP
DET-759A/F 47
8 8
Taille de fusible max. recommandée
AF-600 Bussmann Bussmann Bussmann Bussmann Bussmann Bussmann
[kW]/[HP] Type RK1 Type J Type T Type CC Type CC Type CC
0,75/1 KTS-R-5 JKS-5 JJS-6 FNQ-R-5 KTK-R-5 LP-CC-5
1,5-2,2/2-3 KTS-R-10 JKS-10 JJS-10 FNQ-R-10 KTK-R-10 LP-CC-10
3,7/5 KTS-R20 JKS-20 JJS-20 FNQ-R-20 KTK-R-20 LP-CC-20
5,5/7,5 KTS-R-25 JKS-25 JJS-25 FNQ-R-25 KTK-R-25 LP-CC-25
7,5/10 KTS-R-30 JKS-30 JJS-30 FNQ-R-30 KTK-R-30 LP-CC-30
11-15 / 15-20 KTS-R-35 JKS-35 JJS-35 - - -
18,5/25 KTS-R-45 JKS-45 JJS-45 - - -
22 / 30 KTS-R-50 JKS-50 JJS-50 - - -
30 / 40 KTS-R-60 JKS-60 JJS-60 - - -
37 / 50 KTS-R-80 JKS-80 JJS-80 - - -
45 / 60 KTS-R-100 JKS-100 JJS-100 - - -
55 / 75 KTS-R-125 JKS-125 JJS-125 - - -
75 / 100 KTS-R-150 JKS-150 JJS-150 - - -
90 / 125 KTS-R-175 JKS-175 JJS-175 - - -
Tableau 8.14 525-600 V, 125 HP et inférieur
Taille de fusible max. recommandée
AF-600 SIBA Littel fuseFerraz-
ShawmutFerraz-
Shawmut
[kW]/[HP] Type RK1 Type RK1 Type RK1 Type J
0,75/1 5017906-005 KLS-R-005 A6K-5-R HSJ-6
1,5-2,2/2-3 5017906-010 KLS-R-010 A6K-10-R HSJ-10
3,7/5 5017906-020 KLS-R-020 A6K-20-R HSJ-20
5,5/7,5 5017906-025 KLS-R-025 A6K-25-R HSJ-25
7,5/10 5017906-030 KLS-R-030 A6K-30-R HSJ-30
11-15 / 15-20 5014006-040 KLS-R-035 A6K-35-R HSJ-35
18,5/25 5014006-050 KLS-R-045 A6K-45-R HSJ-45
22 / 30 5014006-050 KLS-R-050 A6K-50-R HSJ-50
30 / 40 5014006-063 KLS-R-060 A6K-60-R HSJ-60
37 / 50 5014006-080 KLS-R-075 A6K-80-R HSJ-80
45 / 60 5014006-100 KLS-R-100 A6K-100-R HSJ-100
55 / 75 2028220-125 KLS-R-125 A6K-125-R HSJ-125
75 / 100 2028220-150 KLS-R-150 A6K-150-R HSJ-150
90 / 125 2028220-200 KLS-R-175 A6K-175-R HSJ-175
Tableau 8.15 525-600 V, 125 HP et inférieur
1) Les fusibles 170M de Bussmann présentés utilisent l'indicateur visuel -/80 : les fusibles avec indicateur –TN/80Type T, -/110 ou TN/110 Type T de même taille et même intensité peuvent être substitués.
Spécifications Guide rapide de l'AF-600 FP
48 DET-759A/F
88
AF-600 triphasé Bussmann Bussmann Bussmann SIBA Littel fuse Ferraz-Shawmut Ferraz-Shawmut
[kW]/[HP] Type RK1 Type J Type T Type RK1 Type RK1 Type RK1 Type J
11 / 15 KTS-R-30 JKS-30 JJS-30 5017906-030 KLS-R-030 A6K-30R HST-30
15 / 20 KTS-R-35 JKS-35 JJS-35 5014006-040 KLS-R-035 A6K-35R HST-35
18,5/25 KTS-R-45 JKS-45 JJS-45 5014006-050 KLS-R-045 A6K-45R HST-45
22 / 30 KTS-R50 JKS-50 JJS-50 5014006-050 KLS-R-50 A6K-50R HST-50
30 / 40 KTS-R-60 JKS-60 JJS-60 5014006-063 KLS-R-060 A6K-60R HST-60
37 / 50 KTS-R-80 JKS-80 JJS-80 5014006-080 KLS-R-075 A6K-80R HST-80
45 / 60 KTS-R-100 JKS-100 JJS-100 5014006-100 KLS-R-100 A6K-100R HST-100
55 / 75 KTS-R125 JKS-125 JJS-125 2028220-125 KLS-125 A6K-125R HST-125
75 / 100 KTS-R150 JKS-150 JJS-150 2028220-150 KLS-150 A6K-150R HST-150
90 / 125 KTS-R175 JKS-175 JJS-175 2028220-200 KLS-175 A6K-175R HST-175
Tableau 8.16 525-690 V, IP21/Nema 1 et IP55/Nema 12
Spécifications Guide rapide de l'AF-600 FP
DET-759A/F 49
8 8
Taille de fusible max. recommandée
AF-600 Bussmann PNAutre fusible
externeBussmann PN
Autre fusibleexterne
Bussmann PN
Autre fusibleexterneSiba PN
Autre fusibleexterne
Littlefuse PN
Autre fusibleexterneFerraz-
Shawmut PN
Autre fusible externeFerraz-Shawmut PN
[kW]/
[HP]Type JFHR2 Type JFHR2 Type T/JDDZ Type JFHR2 Type JFHR2 Type JFHR2
110 /150
170M3017 FWH-300 JJS-300 2028220-315 L50-S-300 A50-P-300
132 /200
170M3018 FWH-350 JJS-350 2028220-315 L50-S-350 A50-P-350
160 /250
170M4012 FWH-400 JJS-400 206xx32-400 L50-S-400 A50-P-400
200 /300
170M4014 FWH-500 JJS-500 206xx32-500 L50-S-500 A50-P-500
250 /
350
170M4016 FWH-600 JJS-600 206xx32-600 L50-S-600 A50-P-600
315 /
450
170M4017 20 610 32.700 6.9URD31D08A0700
355 /500
170M6013 22 610 32.900 6.9URD33D08A0900
400 /550
170M6013 22 610 32.900 6.9URD33D08A0900
450 /600
170M6013 22 610 32.900 6.9URD33D08A0900
500 /650
170M7081
560 /
750
170M7081
630 /900
170M7082
710 /1000
170M7082
800 /1200
170M7083
1000 /1350
170M7083
Tableau 8.17 380-480 V, au-dessus de 125 HP
AF-600 Bussmann PN Caractéristiques nominales Autre fusible Siba PN
[kW]/[HP]
500 / 650 170M8611 1100 A, 1000 V 20 781 32.1000
560 / 750 170M8611 1100 A, 1000 V 20 781 32.1000
630 / 900 170M6467 1400 A, 700 V 20 681 32.1400
710 / 1000 170M6467 1400 A, 700 V 20 681 32.1400
800 / 1200 170M8611 1100 A, 1000 V 20 781 32.1000
1000 / 1350 170M6467 1400 A, 700 V 20 681 32.1400
Tableau 8.18 380-480 V, châssis de taille 6, fusibles du circuit intermédiaire du module d'onduleur
Spécifications Guide rapide de l'AF-600 FP
50 DET-759A/F
88
AF-600Bussmann PN Autre fusible externe
Siba PNAutre fusible externeFerraz-Shawmut PN
[kW]/[HP] Type JFHR2 Type JFHR2
132 / 200 170M3017 2061032,315 6.9URD30D08A0315
160 / 250 170M3018 2061032,35 6.9URD30D08A0350
200 / 300 170M4011 2061032,35 6.9URD30D08A0350
250 / 350 170M4012 2061032,4 6.9URD30D08A0400
315 / 450 170M4014 2061032,5 6.9URD30D08A0500
400 / 550 170M5011 2062032,55 6.9URD32D08A0550
450 / 600 170M4017
500 / 650 170M4017 20 610 32.700 6.9URD31D08A0700
560 / 750 170M6013 20 610 32.700 6.9URD31D08A0700
630 / 900 170M6013 22 610 32.900 6.9URD33D08A0900
710 / 1000 170M7081 22 610 32.900 6.9URD33D08A0900
800 / 1150 170M7081
900 / 1250 170M7081
1000 / 1350 170M7081
1200 / 1600 170M7082
1400 / 1900 170M7083
Tableau 8.19 525-690 V, au-dessus de 125 HP
AF-600 Bussmann PN Caractéristiques nominales Autre fusible Siba PN
[kW]/[HP]
710 / 1000 170M8611 1100 A, 1000 V 20 781 32.1000
800 / 1150 170M8611 1100 A, 1000 V 20 781 32.1000
900 / 1250 170M8611 1100 A, 1000 V 20 781 32.1000
1000 / 1350 170M8611 1100 A, 1000 V 20 781 32.1000
1200 / 1600 170M8611 1100 A, 1000 V 20 781 32.1000
1400 / 1900 170M8611 1100 A, 1000 V 20 781 32.1000
Tableau 8.20 525-690 V, châssis de taille 6, fusibles du circuit intermédiaire du module d'onduleur
* Les fusibles 170M de Bussmann présentés utilisent l'indicateur visuel -/80, les fusibles avec indicateur -TN/80 Type T, -/110 ou TN/110 Type T demême taille et de même intensité peuvent être remplacés pour un usage externe.
** Les fusibles répertoriés d'au moins 500 V UL avec courant nominal associé peuvent être utilisés pour respecter les exigences UL.
Spécifications Guide rapide de l'AF-600 FP
DET-759A/F 51
8 8
9 Borne et fil approprié
9.1 Câbles
Puis
sanc
e [k
W/H
P]Pr
otec
tion
Sect
eur
Mot
eur
Répa
rtiti
on d
e la
cha
rge
Frei
nTe
rre*
200-
240V
380-
480V
525-
600V
525-
690V
Coup
le d
ese
rrag
e[N
m/in
-lb
s]
Taill
e du
câbl
e [m
m2
(AW
G)]
Coup
le d
ese
rrag
e[N
m/in
-lb
s]
Taill
e du
câbl
e [m
m2
(AW
G)]
Coup
le d
ese
rrag
e[N
m/in
-lb
s]
Taill
e du
câbl
e [m
m2
(AW
G)]
Coup
le d
ese
rrag
e[N
m/in
-lb
s]
Taill
e du
câb
le[m
m2 (A
WG
)]
Coup
le d
ese
rrag
e[N
m/in
-lb
s]0,
75-2
,2 k
W 1
-3 H
P0,
75-3
,7 k
W1-
5 H
P
IP
20
1,8/
16
4 (1
0)
1,8/
16
4 (1
0)1,
8/16
4 (1
0)1,
8/16
4 (1
0)
3 /
27
3,7
kW5
HP
5,5-
7,5
kW7,
5-10
HP
0,75
-7,5
kW
1-1
0 H
P
IP20
0,75
-3,7
kW
1-5
HP
0,75
-7,5
kW
1-10
HP
0,75
-7,5
kW
1-1
0 H
P
IP55
ou
IP66
5,5-
11 k
W7,
5-15
HP
11-1
8,5
kW15
-25
HP
11-1
8,5
kW15
-25
HP
IP
2016
(6)
16 (6
)16
(6)
16 (6
)5,
5-11
kW
7,5-
15 H
P11
-18,
5 kW
15-2
5 H
P11
-18,
5 kW
15-2
5 H
P
IP55
ou
IP66
1,5/
141,
5/14
15-1
8,5
kW
20-2
5 H
P
22-3
7 kW
30-5
0 H
P22
-37
kW30
-50
HP
IP
204,
5/40
35 (2
)4,
5/40
35 (2
)4,
5/40
35 (2
)4,
5/40
35 (2
)15
kW
20 H
P22
-30
kW30
-40
HP
22-3
0 kW
30-4
0 H
P11
-30
kW15
-40
HP
IP55
ou
IP66
3,7/
333,
7/33
22-3
0 kW
30-4
0 H
P45
-55
kW60
-75
HP
45-5
5 kW
60-7
5 H
P
IP20
10 /
89
50 (1
)
10 /
89
50 (1
)
10 /
89
50 (1
)
10 /
89
50 (1
)
18,5
-30
kW
25-4
0 H
P
37-5
5 kW
50-7
5 H
P37
-55
kW50
-75
HP
IP
55 o
uIP
6690
(3/0
)90
(3/0
)90
(3/0
)90
(3/0
)
37-4
5 kW
50-6
0 H
P75
-90
kW10
0-12
5 H
P
75-9
0 kW
100-
125
HP
IP
20
14 /
124
150
(300
mcm
)14
/ 1
24
150
(300
mcm
)14
/ 1
24
95 (4
/0)
14 /
124
95 (4
/0)
37-4
5 kW
50-6
0 H
P75
-90
kW10
0-12
5 H
P
75-9
0 kW
100-
125
HP
37-9
0 kW
50-1
25 H
PIP
55 o
uIP
6612
0 (4
/0)
120
(4/0
)12
0 (4
/0)
120
(4/0
)
11
0-13
2 kW
150-
200
HP
11
0-16
0 kW
150-
250
HP
tout
es
19 /
168
2 x
70 (2
x2/
0)
19 /
168
2 x
70 (2
x2/
0)9,
5/84
2 x
70 (2
x2/
0)
9,5/
84
2 x
70 (2
x2/
0)
19 /
168
16
0-25
0 kW
250-
350
HP
20
0-40
0 kW
300-
550
HP
tout
es2
x 18
5(2
x 3
50 m
cm
)
2 x
185
(2 x
350
mcm
)
2 x
185
(2 x
350
mc
m)
2 x
185
(2 x
350
mcm
)
315-
450
kW45
0-60
0 H
P
450-
630
kW60
0-90
0 H
Pto
utes
4 x
240
(4 x
500
mc
m)
4 x
240
(4 x
500
mcm
)
19 /
168
4 x
240
(4 x
500
mc
m)
50
0-71
0 kW
650-
1000
HP
71
0-90
0 kW
1000
-125
0 H
Pto
utes
8 x
240
(8 x
500
mc
m)
8 x
150
(8 x
300
mcm
)4
x 12
0(4
x 2
50 m
cm
)
4 x
185
(4 x
350
mcm
)
80
0-10
00 k
W12
00-1
350
HP
10
00-1
400
kW13
50-1
900
HP
tout
es12
x 1
50(1
2 x
300
mc
m)
6 x
185
(6 x
350
mcm
)
* Se
ctio
n d
e câ
ble
max
imal
e co
nfor
me
au c
ode
natio
nal
Borne et fil approprié Guide rapide de l'AF-600 FP
52 DET-759A/F
99
1 Sicurezza
AVVISOALTA TENSIONE!I convertitori di frequenza sono soggetti ad alta tensionequando collegati all'alimentazione di ingresso della reteCA. L'installazione, l'avviamento e la manutenzionedovrebbero essere eseguiti solo da personale qualificato.Se l'installazione, l'avvio e la manutenzione non vengonoeseguiti da personale qualificato potrebbero presentarsirischi di lesioni gravi o mortali.
Alta tensioneI convertitori di frequenza sono collegati a tensioni elevatee potenzialmente pericolose. È necessario prestareattenzione per evitare folgorazioni. Queste apparecchiaturedovrebbero essere installate, avviate o manutenute solo dapersonale adeguatamente formato e esperto negliinterventi su apparati elettrici.
AVVISOAVVIO INVOLONTARIO!Quando il convertitore di frequenza è collegato all'alimen-tazione di rete CA, il motore può avviarsi in qualsiasimomento. Il convertitore di frequenza, il motore e ogniapparecchiatura azionata devono essere pronti per ilfunzionamento. In caso contrario quando si collega ilconvertitore di frequenza alla rete CA possono verificarsigravi lesioni, morte o danneggiamenti alle apparecchiatureo alle proprietà.
Avvio involontarioQuando il convertitore di frequenza è collegato all'alimen-tazione di rete CA, il motore può avviarsi in seguito a uncomando proveniente da un interruttore esterno, da unbus seriale, da un segnale in ingresso di riferimento o dalripristino di una condizione di guasto. Adottare sempre leopportune precauzioni per proteggersi dagli avviamentiinvolontari.
AVVISOTEMPO DI SCARICA!I convertitori di frequenza contengono condensatori delbus CC che rimangono carichi anche dopo aver scollegatol'alimentazione. Per evitare il rischio di scariche elettriche,scollegare l'alimentazione di rete dal convertitore difrequenza prima di eseguire qualsiasi intervento dimanutenzione e attendere il tempo specificato interventoTabella 1.1. Non attendere per il tempo indicato dopo ildisinserimento dell'alimentazione, può causare lesioni gravio anche mortali.
Tensione PotenzaTempo di attesaminimo
200 - 240V0,75 - 3,7kW 1 - 5HP 4 minuti
5,5 - 45kW 7,5 - 60HP 15 minuti
380 - 480V
0,75 - 7,5kW 1 - 10HP 4 minuti
11 - 90kW 15 - 125HP 15 minuti
110 - 250kW150 - 350HP
20 minuti
315 - 1000kW450 - 1350HP
40 minuti
525 - 600V
0,75 - 7,5kW 1 - 10HP 4 minuti
11 - 90kW 15 - 125HP 15 minuti
110 - 315kW
150 - 400HP20 minuti
355 - 1000kW450 - 1350HP
30 minuti
525 - 690V
11 - 75kW15 - 125HP
15 minuti
110 - 400kW150 - 550HP
20 minuti
400 - 1400kW600- 1900HP
30 minuti
SimboliNel presente manuale vengono utilizzati i seguenti simboli.
Sicurezza Guida rapida AF-600 FP
DET-759A/I 1
1 1
AVVISOIndica una situazione potenzialmente rischiosa che, se nonevitata, potrebbe causare morte o lesioni gravi.
ATTENZIONEIndica una situazione potenzialmente rischiosa che, se nonevitata, può causare lesioni leggere o moderate. Potrebbeessere utilizzata anche per avvisare di pratiche non sicure.
ATTENZIONEIndica una situazione che potrebbe causare incidenti condanni alle apparecchiature o a proprietà.
NOTA!Evidenzia informazioni che dovrebbero essere consideratecon attenzione per evitare errori o un funzionamento delsistema con prestazioni inferiori a quelle ottimali,
Approvazioni
Sicurezza Guida rapida AF-600 FP
2 DET-759A/I
11
2 Introduzione
Disegno 2.1 Vista esplosa dimensione unità 1X
1 Tastiera 10 Morsetti di uscita del motore 96 (U), 97 (V), 98 (W)
2 Connettore bus seriale RS-485 (+68, -69) 11 Relè 1 (01, 02, 03)
3 Connettore I/O analogico 12 Relè 2 (04, 05, 06)
4 Spina di ingresso Tastiera 13 Morsetti freno (-81, +82) e condivisione del carico (-88, +89)
5 Interruttori analogici (A53), (A54) 14 Morsetti ingresso rete 91 (L1), 92 (L2), 93 (L3)
6 Fissacavi / PE massa 15 Connettore USB
7 Piastra di disaccoppiamento 16 Interruttore morsetto bus seriale
8 Morsetto di messa a terra (PE) 17 I/O digitale e alimentazione 24 V
9 Morsetto di messa a terra cavo schermato e fissacavi 18 Piastra di copertura per cavo di comando
NOTA!Consultare il manuale di funzionamento AF-600 FP per altre dimensioni prodotto.
Introduzione Guida rapida AF-600 FP
DET-759A/I 3
2 2
3 Installazione
3.1 Check list per l'installazione in sito
• Il convertitore di frequenza sfrutta l'aria ambienteper il raffreddamento. Osservare le limitazionirelative alla temperatura dell'aria ambiente per unfunzionamento ottimale
• Assicurarsi che il sito di installazione offra ilsostegno adeguato per l'installazione delconvertitore di frequenza
• Mantenere la parte interna del convertitore difrequenza priva di polvere o sporco. Assicurare lamassima pulizia dei componenti. Nelle aree diinstallazione utilizzare una copertura diprotezione. Potrebbero essere necessarie custodieopzionali IP54 (NEMA 12).
• Mantenere a disposizione il manuale, i disegni egli schemi per consultare le istruzioni di instal-lazione e funzionamento dettagliate. Il manualedeve essere disponibile anche per gli operatoridell'apparecchiatura.
• Collocare l'apparecchiatura il più vicino possibileal motore. Fare in modo che i cavi del motoresiano quanto più corti possibile. Controllare lecaratteristiche del motore per le tolleranzeeffettive. Non superare
• 300m (1000ft) per cavi motore nonschermati
• 150m (500ft) per cavo schermato.
3.2 Lista di controllo Convertitore difrequenza e di preinstallazione delmotore
• Confrontare il numero di modello dell'unità sullatarghetta dati con l'ordine per verificarne lacorrettezza
• Assicurare che abbiano la stessa tensionenominale:
Rete (alimentazione)
Convertitore di frequenza
Motore
• Assicurarsi che l'uscita corrente nominale delconvertitore di frequenza sia maggiore o ugualealla corrente a pieno carico per prestazioni dipicco del motore.
Taglia del motore e potenza delconvertitore di frequenza devonocorrispondere per una correttaprotezione dal sovraccarico
Se la taglia del convertitore di frequenzaè inferiore a quella del motore non èpossibile ottenere la potenza massimadel motore.
3.3 Installazione meccanica
3.3.1 Raffreddamento
• Per fornire un flusso d'aria di raffreddamento,montare l'unità su una superficie piana robusta osulla piastra posteriore opzionale.
• Assicurare una distanza minima per il raffred-damento dell'aria per la parte superiore einferiore. Generalmente sono richiesti 100-225mm(4-10 poll.).
• Un montaggio non ottimale può causare surriscal-damento e prestazioni ridotte
• Deve essere considerato un declassamento pertemperature tra 40°C (104°F) e 50°C (122°F) eun'altezza di 1000m (3300ft) sopra il livello delmare. Per ulteriori informazioni, vedere la Guidaalla Progettazione.
Disegno 3.1 Distanza di raffreddamento superiore e inferiore
Installazione Guida rapida AF-600 FP
4 DET-759A/I
33
Tensione Potenza Distanza a/b
200 - 240V
0,25 - 3,7kW 1/3 - 5HP 100mm / 4 poll.
5,5 - 30kW 7,5 - 40HP 200mm / 8 poll.
> 30kW / 40HP 225mm / 10 poll.
380 - 480V
0,37 - 7,5kW 1/2 - 10HP 100mm / 4 poll.
11 - 55kW 15 - 75HP 200mm / 8 poll.
> 55kW / 75HP 225mm / 10 poll.
525 - 600V
0,37 - 7,5kW 1/2 - 10HP 100mm / 4 poll.
11 - 55kW 15 - 75HP 200mm / 8 poll.
> 55kW / 75HP 225mm / 10 poll.
525 - 690V tutti 225mm / 10 poll.
Tabella 3.1 Requisiti relativi alla distanza minima per il flusso d'aria
3.3.2 Sollevamento
• Controllare il peso dell'unità per determinare unmetodo di sollevamento sicuro.
• Assicurare che il dispositivo di sollevamento siaidoneo per il compito
• Se necessario, prevedere l'utilizzo di un paranco,una gru o un muletto della portata corretta perspostare l'unità
• Per il sollevamento, utilizzare i golfari sull'unità, sein dotazione
3.3.3 Montaggio
• Montare l'unità verticalmente
• Il convertitore di frequenza consente l'instal-lazione affiancata
• Assicurarsi che il sito di installazione sia in gradodi sopportare il peso dell'unità
• Montare l'unità su una superficie piana robusta osulla piastra posteriore opzionale per fornire ilflusso d'aria di raffreddamento (vedi Disegno 3.2 eDisegno 3.3)
• Un montaggio non ottimale può causare surriscal-damento e prestazioni ridotte
• Utilizzare i fori di montaggio scanalati sull'unitàper il montaggio a parete, se in dotazione
Disegno 3.2 Montaggio corretto con la piastra posteriore
L'elemento A è una piastra posteriore correttamentemontata per il flusso d'aria richiesto per raffreddare l'unità.
Disegno 3.3 Montaggio corretto con barre
NOTA!La piastra posteriore è richiesta per il montaggio su barre.
Installazione Guida rapida AF-600 FP
DET-759A/I 5
3 3
3.4 Installazione elettrica
Questa sezione contiene istruzioni dettagliate per il cablaggio del convertitore di frequenza. Sono descritte le seguentioperazioni.
• Cablaggio del motore al convertitore di frequenza morsetti di uscita
• Cablaggio della rete CA al convertitore di frequenza morsetti di ingresso
• Collegamento del controllo e cablaggio della comunicazione seriale
• Una volta inserita l'alimentazione, controllare l'ingresso e la potenza motore; programmazione dei morsetti dicontrollo per le loro funzioni previste
Disegno 3.4 mostra un collegamento elettrico di base.
Disegno 3.4 Schema di cablaggio base.
Installazione Guida rapida AF-600 FP
6 DET-759A/I
33
3.4.1 Requisiti
AVVISOPERICOLO APPARECCHIATURE!Alberi rotanti e apparecchiature elettriche possonodiventare pericolosi. Osservare le norme locali e nazionaliin materia di sicurezza per installazioni elettriche. Èfortemente consigliato far effettuare l'installazione, l'avvio ela manutenzione solo da personale qualificato eaddestrato. L'inosservanza delle linee guida può causarelesioni gravi o mortali.
ATTENZIONEISOLAMENTO DEI CAVI!Introdurre la potenza di ingresso, il cablaggio motore e icavi di controllo in tre condotti metallici separati o usareun cavo schernato separato per l'isolamento dai disturbi adalta frequenza. Il mancato isolamento dei cavi di alimen-tazione, motore e controllo potrebbe causare prestazioninon ottimali del convertitore di frequenza e dell'apparec-chiatura associata.
Per garantire la sicurezza, considerare quanto segue.
• I dispositivi di controllo elettronici sono collegatia tensioni di rete pericolose. È necessario prestareattenzione per evitare folgorazioni quando sialimenta l'unità.
• Posare separatamente i cavi motore da conver-titori di frequenza multipli. La tensione indotta dacavi motore in uscita posati insieme può caricarei condensatori dell'apparecchiatura anche quandoquesta è spenta e disinserita.
Protezione da sovraccarico e dell'apparecchiatura
• Una funzione attivata elettronicamente eintegrata nel convertitore di frequenza offre unaprotezione da sovraccarico per il motore. Ilsovraccarico calcola il livello di aumento perattivare la temporizzazione della funzione discatto (arresto uscita controllore). Maggiore èl'assorbimento di corrente, più rapida è la rispostadi intervento. La protezione da sovraccarico delmotore fornita è di classe 20. Vedere 7 Avvisi eallarmi per dettagli sulla funzione di scatto.
• Poiché i cavi del motore portano corrente ad altafrequenza, è importante che i cavi per la rete, lapotenza motore e il controllo vengano posatiseparatamente. Utilizzare canaline metalliche ocavi schermati separati. Il mancato isolamento delcablaggio di alimentazione, motore e controllopotrebbe causare prestazioni dell'apparecchiaturanon ottimali.
• Tutti i convertitori di frequenza devono essereprovvisti di una protezione da cortocircuito e dasovracorrente. È necessario un fusibile di ingressoper fornire questa protezione, vedi Disegno 3.5.Vedere le prestazioni massime dei fusibili in8.2.2 Conformità CE e 8.2.3 Tabelle fusibili.
Disegno 3.5 Convertitore di frequenza Fusibili
Tipi e caratteristiche dei cavi
• Tutti i cavi devono rispettare sempre le normenazionali e locali relative alle sezioni dei cavi ealla temperatura ambiente.
• GE consiglia che tutti i collegamenti di potenzasiano realizzati con fili di rame adatto per almeno75° C.
3.4.2 Requisiti di messa a terra
AVVISORISCHIO DI MESSA A TERRA ERRATA!Per la sicurezza degli operatori, è importante realizzare uncorretta messa a terra del convertitore di frequenza in baseai codici elettrici nazionali e locali nonché alle istruzioniriportate nel presente documento. Le correnti di terra sonosuperiori a 3,5 mA. Una messa a terra non appropriata delconvertitore di frequenza può causare morte o lesionigravi.
NOTA!È responsabilità dell'utente o dell'installatore certificatoassicurare una corretta messa a terra dell'apparecchiaturain base ai codici e agli standard elettrici nazionali e locali.
• Seguire tutti i codici elettrici nazionali e locali peruna corretta messa a terra dell'apparecchiatura
• È necessario utilizzare una messa a terra diprotezione per apparecchiature con correnti diterra superiori a 3,5 mA, vedere Corrente didispersione (>3,5mA)
Installazione Guida rapida AF-600 FP
DET-759A/I 7
3 3
• È necessario un cavo di terra dedicato perl'alimentazione di ingresso, , l'alimentazione delmotore e i cavi di controllo
• Utilizzare i morsetti in dotazione all'apparec-chiatura per assicurare collegamenti di massaidonei
• Non collegare a massa un convertitore difrequenza con un altro in una configurazione deltipo "a margherita"
• Tenere i cavi di terra il più corti possibile.
• È consigliato l'utilizzo di un cavo cordato perridurre i disturbi elettrici
• Rispettare i requisiti del costruttore del motorerelativi al cablaggio
3.4.2.1 Corrente di dispersione (>3,5 mA)
Rispettare le norme locali vigenti relative alla messa a terradi apparati con correnti di dispersione > 3,5 mA.La tecnologia dei Convertitore di frequenza implicacommutazione ad alta frequenza e alta potenza. Questogenera correnti di dispersione a terra. Una corrente diguasto nel convertitore di frequenza sui morsetti dipotenza di uscita può contenere una componente CC ingrado di caricare i condensatori filtro causando dellecorrenti transitorie verso terra. La corrente di dispersioneverso terra dipende dalle diverse configurazioni delsistema, inclusi i circuiti di filtraggio RFI, i cavi motoreschermati e la potenza del convertitore di frequenza.
La norma EN/IEC61800-5-1 (Azionamenti elettrici a velocitàvariabile ) prevede particolari precauzioni se la corrente didispersione supera i 3,5 mA,. La messa a terra deve esserepotenziata in uno dei modi seguenti:
• Cavo di terra di sezione minima 10 mm2
• Due cavi di terra separati, entrambi di dimensioniadeguate a quanto previsto dalla norma
Per ulteriori informazioni vedere la norma EN 60364-5-54 §543.7
Utilizzare i RCDQuando si utilizzano dispositivi a corrente residua (RCD),detti anche interruttori automatici (ELCB) con dispersione aterra, rispettare le seguenti regole:
Utilizzare solo RCD di tipo B, in grado di rilevarecorrenti CA e CC.
Utilizzare RCD con ritardo per i picchi in ingressoper evitare guasti dovuti a correnti di terratransitorie.
Dimensionare l'RCD in funzione della configu-razione del sistema e di considerazioni ambientali.
3.4.2.2 Messa a terra con cavo schermato
Sono in dotazione morsetti di messa a terra per ilcablaggio del motore (vedere Disegno 3.6).
Disegno 3.6 Messa a terra con cavo schermato
3.4.2.3 Messa a terra tramite canaline
ATTENZIONERISCHIO DI MESSA A TERRA ERRATA!Non utilizzare canaline collegate al convertitore difrequenza in alternativa a una corretta messa a terra. Lecorrenti di terra sono superiori a 3,5 mA. Una messa a terrainadeguata può causare lesioni personali o cortocircuiti.
Sono previsti in dotazione morsetti di messa a terra(vedere Disegno 3.7).
Disegno 3.7 Messa a terra con canaline
Installazione Guida rapida AF-600 FP
8 DET-759A/I
33
Disegno 3.8 Collegamento di motore, rete e terra per dimensionitelaio 2X e superiori utilizzando cavi schermati
1. Utilizzare una spelafili per rimuovere l'isolamentoper una corretta messa a terra.
2. Fissare il morsetto di messa a terra alla partespellata del filo utilizzando le viti in dotazione.
3. Fissare il cavo di messa a terra al morsetto dimessa a terra in dotazione.
3.4.3 Collegamento del motore
AVVISOTENSIONE INDOTTA!Posare separatamente i cavi motore in uscita dai conver-titori di frequenza multipli. La tensione indotta da cavimotore in uscita posati insieme può caricare i condensatoridell'apparecchiatura anche quando questa è spenta edisinserita. Il mancato rispetto della posa separata dei cavidi uscita del motore può causare morte o lesioni gravi.
• Rispettare le normative locali e nazionali per ledimensioni dei cavi, vedere
• Sono presenti passacavi per i cavi del motore opannelli di accesso sulla base dell'unità IP55 /Nema 12 e IP66 / Nema 4X Indoor
• Non montare condensatori di rifasamento tra ilconvertitore di frequenza e il motore.
• Non collegare un dispositivo di avviamento o acommutazione di polo tra il convertitore difrequenza e il motore
• Collegare il cablaggio trifase del motore aimorsetti 96 (U), 97 (V) e 98 (W)
• Collegare a massa il cavo seguendo le istruzionidi messa a terra fornite
• Rispettare i requisiti del costruttore del motorerelativi al cablaggio
Le tre figure seguenti rappresentano i collegamenti peringresso di rete, motore e messa a terra per convertitori difrequenza di base. Le configurazioni effettive variano inbase ai tipi di unità e alle attrezzature opzionali.
3.4.4 Collegamento alla rete CA
• Dimensionare il cablaggio sulla base dellacorrente di ingresso del convertitore di frequenza.
• Rispettare i codici elettrici locali e nazionali per ledimensioni dei cavi, vedere .
• Collegare i cavi dell'alimentazione di ingresso CAtrifase ai morsetti L1, L2 e L3.
• La corrente di ingresso verrà collegata ai morsettidi ingresso della rete.
• Collegare a massa il cavo seguendo le istruzionidi messa a terra fornite in 3.4.2 Requisiti di messaa terra
• È possibile utilizzare tutti i convertitori difrequenza con un'alimentazione di ingressoisolata e con linee di alimentazione riferite amassa. Per l'alimentazione da una rete isolata(rete IT o triangolo non a terra) o rete TT/TN-Scon neutro a terra (triangolo a terra), impostareSP-50 Filtro RFI su OFF. Con l'impostazione OFF, icondensatori del filtro RFI interno fra il telaio e ilcircuito intermedio sono isolati per evitare dannial circuito intermedio e ridurre le correnticapacitive di terra in conformità a IEC 61800-3.
3.4.5 Cavi di controllo
• Isolare i cavi del controllo dai componenti ad altapotenza nel convertitore di frequenza.
• Se il convertitore di frequenza è collegato a untermistore, per l'isolamento PELV, è necessarioutilizzare un isolamento rinforzato/doppio per ilcablaggio del controllo del termistore opzionale.Si raccomanda una tensione di alimentazione di24 VCC.
3.4.5.1 Accesso
• Rimuovere la piastra della copertura di accessocon un cacciavite. Vedere Disegno 3.9.
• Oppure rimuovere la copertura anterioreallentando le viti di fissaggio. VedereDisegno 3.10.
Installazione Guida rapida AF-600 FP
DET-759A/I 9
3 3
La coppia di serraggio per il coperchio anteriore è2,0Nm per grandezze di unità 15 e 2,2Nm pergrandezze di unità 2X e 3X.
Disegno 3.9 Controllare l'accesso ai cablaggi per le custodieIP20 / Open chassis
Disegno 3.10 Controllare l'accesso ai cablaggi per IP55 / Nema12 e IP66 / Nema 4/4X Indoor
3.4.5.2 Tipi di morsetti di comando
Disegno 3.14 mostra i connettori rimovibili del convertitoredi frequenza. Le funzioni dei morsetti e le relativeimpostazioni predefinite sono elencate in Tabella 3.2.
Disegno 3.11 Posizioni dei morsetti di controllo
• Connettore 1 presenta quattro morsetti per gliingressi digitali programmabili, due morsettidigitali aggiuntivi programmabili come ingressi ouscite, un morsetto di alimentazione 24 VCC, e unmorsetto comune per l'alimentazione opzionale24 VCC fornita dall'utilizzatore.
• I morsetti (+)68 e (-)69 del Connettore 2 servonoper un collegamento RS-485 comunicazioni seriali.
• Connettore 3 mette a disposizione due ingressianalogici, una uscita analogica, alimentazione da10V CC e morsetti comuni per gli ingressi el'uscita.
• Connettore 4 è una porta USB disponibile perl'utilizzo con DCT-10
• Sono inoltre previste due uscite a relè forma C invarie collocazioni in base alla configurazione delconvertitore di frequenza e alla taglia.
• Alcune opzioni disponibili su ordinazione con leunità possono offrire ulteriori morsetti. Vedere ilmanuale in dotazione all'apparecchiaturaopzionale.
Vedere 8.1 Dati tecnici generali per definizioni e dettagli.
Installazione Guida rapida AF-600 FP
10 DET-759A/I
33
Descrizione del morsettoIngressi/uscite digitali
MorsettoRiferiment
oImpostazione
di default Descrizione12, 13 - +24V CC Tensione di alimen-
tazione 24V CC. Lacorrente in uscitamassima è di 200 mAin totale per tutti icarichi a 24 V. Utiliz-zabile per ingressidigitali e trasduttoriesterni.
18 E-01 [8] Avviam.
Ingressi digitali.
19 E-02 [0] Nessunafunzione
32 E-05 [0] Nessunafunzione
33 E-06 [0] Nessuna
funzione
27 E-03 [0] Nessuna
funzione
Selezionabile come
ingresso o uscitadigitale. L'impo-stazione predefinita è
ingresso.
29 E-04 [14] JOG
20 - Comune per gliingressi digitali e 0 vper l'alimentazione 24V.
Ingressi/uscite analogici
39 -
Comune per uscitaanalogica
42 AN-50 Limite alto -
velocità 0
Uscita analogica
programmabile Ilsegnale analogico è0-20 mA oppure 4-20
mA, a 500 Ω massimo.
50 - +10V CC Tensione di alimen-tazione analogica 10VCC. 15 mA massima,tipicamente utilizzataper un potenziometroo un termistore.
53 AN-1# Riferimento Ingresso analogico.
Selezionabile pertensione o corrente.Gli interruttori A53 e
A54 permettono discegliere mA o V.
54 AN-2# Retroazione
55 -
Comune per l'ingressoanalogico
Comunicazione seriale
Descrizione del morsettoIngressi/uscite digitali
MorsettoRiferiment
oImpostazione
di default Descrizione61 -
Filtro RC integrato perschermatura cavo.SOLO per collegare laschermatura in caso diproblemi EMC.
68 (+) O-3# Interfaccia RS-485. Perla resistenza diterminazione èdisponibile uninterruttore sullascheda di comando.
69 (-) O-3#
Relè
01, 02, 03 E-24 [0] [0] Allarme Uscita a relè forma CUtilizzabile pertensione CA o CC ecarichi induttivi oresistivi.
04, 05, 06 E-24 [1] [0] In funzione
Tabella 3.2 Descrizione del morsetto
3.4.5.3 Collegamento ai morsetti dicontrollo
I connettori dei morsetti di controllo sono scollegabili dalconvertitore di frequenza per facilitare l'installazione, comemostrato in Disegno 3.12.
Disegno 3.12 Disinserimento dei morsetti di controllo
1. Aprire il contatto inserendo un piccolo cacciavitenella fessura al di sopra o al di sotto del contatto,come mostrato in Disegno 3.13.
2. Inserire il cavo di controllo spelato direttamentenel contatto.
3. Rimuovere il cacciavite per fissare il filo dicontrollo nel contatto.
Installazione Guida rapida AF-600 FP
DET-759A/I 11
3 3
4. Assicurare che il contatto sia ben saldo e nonallentato. Un cavo di controllo allentato puòcausare guasti all'apparecchiatura o un funzio-namento non ottimale.
Disegno 3.13 Collegamento dei fili di controllo
3.4.5.4 Usando cavi di comando schermati
Schermatura correttaIn molti casi, la soluzione preferita è quella di proteggere icavi di comando e di comunicazione seriale con morsettidi schermatura ad entrambi gli estremi per garantire ilmigliore contatto possibile alle alte frequenze.
Ritorni di massa da 50/60HzSe si usano cavi di controllo, molto lunghi, si possonoavere ritorni di massa. Per eliminare i ritorni di massa,collegare un'estremità della schermatura a massa con uncondensatore da 100 nF (tenendo i cavi corti).
Eliminare i disturbi EMC nella comunicazione serialePer eliminare i disturbi a bassa frequenza tra convertitori difrequenza, collegare un'estremità della schermatura almorsetto 61. Questo morsetto è collegato a massamediante un collegamento RC interno. Utilizzare cavi adoppino intrecciato per ridurre l'interferenza tra conduttori.
3.4.5.5 Funzioni dei morsetti di comando
Le funzioni del Convertitore di frequenza sono attivate daisegnali dell'ingresso di controllo.
• Ogni morsetto deve essere programmato per lafunzione supportata nei parametri associati almorsetto specifico. Vedere Tabella 3.2 per imorsetti e i parametri associati.
• È importante confermare che il morsetto dicontrollo sia programmato per la funzionecorretta.
• La programmazione predefinita per i morsetti halo scopo di inizializzare il funzionamento delconvertitore di frequenza in una modalità tipica.
3.4.5.6 Morsetto 53 e 54 interruttori
• I morsetti 53 e 54 di segnale di ingressoanalogico consentono la selezione dei segnali diingresso in tensione (da 0 a 10 V) o corrente(0/4-20 mA)
• Togliere l'alimentazione al convertitore difrequenza prima di cambiare le posizioni dell'in-terruttore
• Impostare gli interruttori A53 e A54 perselezionare il tipo di segnale. U seleziona latensione, I seleziona la corrente.
• Gli interruttori sono accessibili quando tastiera èstato smontato (vedere Disegno 3.14). Alcuneschede opzionali disponibili per le unità possonocoprire questi interruttori e devono quindi essererimosse per cambiarne la configurazione.Scollegare sempre l'alimentazione dall'unità primadi rimuovere le schede opzionali.
• Il valore di Morsetto 53 predefinito è per unsegnale di riferimento di velocità a anello apertoimpostato in DR-61 Mors. 53 impost. commut.
• Il valore di Morsetto 54 predefinito è per unsegnale di retroazione a anello chiuso impostatoin DR-63 Mors. 54 impost. commut.
Installazione Guida rapida AF-600 FP
12 DET-759A/I
33
130BT310.10
Disegno 3.14 Posizione dei morsetti 53 e 54 Interruttori
3.4.6 Comunicazione seriale
è un'interfaccia bus a due fili compatibile con topologia direte multi-drop, vale a dire che i nodi possono esserecollegati come un bus oppure tramite linee di discesa dauna linea dorsale comune. Un totale di 32 nodi possonoessere collegati a un segmento di rete.I ripetitori separano i vari segmenti di rete. È necessariotenere presente che ogni ripetitore funziona come unnodo all'interno del segmento nel quale è installato. Ogninodo collegato all'interno di una data rete deve avere unindirizzo di nodo unico attraverso tutti i segmenti.Terminare entrambe le estremità di ogni segmentoutilizzando lo switch di terminazione (S801) dei convertitoridi frequenza oppure una rete resistiva polarizzata diterminazione. Utilizzare sempre un cavo a coppiaintrecciata (STP) per il cablaggio del bus e, nell'effettuarel'installazione, seguire sempre le procedure consigliate.È molto importante assicurare un collegamento a massa abassa impedenza della schermatura in corrispondenza diogni nodo, anche alle alte frequenze. Ciò può essereottenuto collegando a massa un'ampia superficie dellaschermatura, ad esempio mediante un pressacavo o unpassacavo conduttivo. Può essere necessario utilizzare cavidi equalizzazione del potenziale per mantenere lo stessopotenziale di massa in tutta la rete, soprattutto nelle instal-lazioni nelle quali sono presenti cavi molto lunghi.Per prevenire un disadattamento d'impedenza, utilizzaresempre lo stesso tipo di cavo in tutta la rete. Quando sicollega un motore al convertitore di frequenza, utilizzaresempre un cavo motore schermato.
Cavo: a coppia intrecciata schermata (STP)
Impedenza: 120ΩLunghezza dei cavi: Max. 1200 m (incluse le diramazioni)
Max. 500 m da stazione a stazione
Installazione Guida rapida AF-600 FP
DET-759A/I 13
3 3
4 Avviamento e test funzionale
4.1 Pre-avvio
4.1.1 Controllo di sicurezza
AVVISOALTA TENSIONE!Se i collegamenti di ingresso e uscita sono stati collegati inmodo non ottimale, possono presentarsi tensioni elevatesu questi morsetti. Se i conduttori di alimentazione per piùmotori sono posati in modo erroneo nella stessa canalina,sussiste il rischio che la corrente di dispersione carichi icondensatori all'interno del convertitore di frequenzaanche se scollegati dall'alimentazione di rete. Per l'avvioiniziale, attenersi alle procedure relative ai componenti dialimentazione. Attenersi alle procedure di pre-avvio. Ilmancato rispetto delle procedure di pre-avvio potrebbecausare lesioni personali o danni all'apparecchiatura.
1. L'alimentazione in ingresso all'unità deve esserespenta ed esclusa (Lock-out). Non basarsi suisezionatori del convertitore di frequenza perl'isolamento dell'alimentazione di ingresso.
2. Verificare che non sia presente tensione suimorsetti di ingresso L1 (91), L2 (92), e L3 (93), trafase e fase e tra fase e terra,
3. Verificare che non sia presente tensione suimorsetti di uscita 96 (U), 97(V) e 98 (W), tra fase efase e tra fase e terra.
4. Confermare la continuità del motore misurando ilvalore di resistenza (ohm) su U-V (96-97), V-W(97-98) e W-U (98-96).
5. Controllare che la messa a terra del convertitoredi frequenza e del motore sia idonea.
6. Controllare eventuali collegamenti allentati suimorsetti del convertitore di frequenza.
7. Registrare i seguenti dati di targa del motore:potenza, tensione, frequenza, corrente a pienocarico e velocità nominale. Questi valori sononecessari per una successiva programmazione deidati di targa del motore.
8. Confernare che la tensione di rete corrispondaalla tensione del convertitore di frequenza e delmotore.
Avviamento e test funzional... Guida rapida AF-600 FP
14 DET-759A/I
44
4.1.2 Check list all'avvio
ATTENZIONEPrima di alimentare l'unità, controllare l'intera installazione in base a quanto riportato in Tabella 4.1. In seguito marcarequegli elementi.
Controllare Descrizione Apparecchiatura ausiliaria • Controllare l'apparecchiatura ausiliaria, interruttori, sezionatori o interruttori
automatici/fusibili di ingresso eventualmente presenti sul lato di alimentazionedi ingresso del convertitore di frequenza e sul lato di uscita verso il motore.Assicurarsi che sono pronti per il funzionamento a piena velocità.
• Controllare il funzionamento e l'installazione degli eventuali sensori utilizzatiper la retroazione al convertitore di frequenza.
• Rimuovere i condensatori di rifasamento sui motori, se presente.
Posizionamanto cavi • Assicurare che l'alimentazione di ingresso, il cablaggio motore e i cavi dicontrollo siano separati o in tre canaline metalliche separate per l'isolamentodai disturbi ad alta frequenza.
Cavi di controllo • Controllare che non vi siano eventuali fili rotti o danneggiati e collegamnetinon serrati.
• Controllare che i cavi di controlli siano isolati dal cablaggio di alimentazione edai cavi motore per assicurare l'immunità ai disturbi.
• Controllare la sorgente di tensione dei segnali, se necessario.
• Si consiglia l'utilizzo di cavi schermati o doppini intrecciati. Assicurarsi che laschermatura sia terminata correttamente.
Distanza per il raffreddamento • Misurare lo spazio superiore e inferiore per assicurare un flusso d'ariasufficiente per il raffreddamento.
Considerazioni EMC • Controllare che l'installazione sia conforme ai requisiti di compatibilità elettro-magnetica.
Considerazioni ambientali • Vedere l'etichetta dell'apparecchiatura per i limiti della temperatura di esercizioambiente massima.
• I livelli di umidità devono essere pari al 5-95% senza condensa.
Fusibili e interruttori automatici • Controllare il corretto dimensionamento di fusibili e interruttori automatici.
• Controllare che tutti i fusibili siano inseriti saldamente e in condizioni ottimalidi funzionamento e che tutti gli interruttori automatici siano in posizioneaperta.
Messa a terra • L'unità richiede un cavo di massa dal suo telaio alla massa dell'edificio.
• Controllare che i collegamenti di massa siano serrati e senza ossidazione.
• La messa a terra sulla canalina o il montaggio del pannello posteriore su unasuperficie metallica non offre una massa adeguata
Cavi di alimentazione diingresso e uscita
• Controllare se vi sono collegamenti allentati.
• Controllare che il motore e la rete siano in canaline separate o in cavischermati separati.
Pannello interno • Verificare che l'interno dell'unità sia priva di sporcizia, trucioli di metallo,umidità e corrosione.
Interruttori • Assicurarsi che tutti gli interruttori e sezionatori siano impostati nelle posizioni
corrette.
Avviamento e test funzional... Guida rapida AF-600 FP
DET-759A/I 15
4 4
Controllare Descrizione Vibrazioni • Assicurarsi che l'unità sia montata saldamente o che vengano usati supporti
antivibrazioni, se necessario.
• Controllare se sono presenti vibrazioni eccessive.
Tabella 4.1 Check list all'avvio
4.2 Applicazione di corrente al Convertitore di frequenza
AVVISOALTA TENSIONE!I convertitori di frequenza sono soggetti ad alta tensionequando collegati alla rete CA. L'installazione, l'avvio e lamanutenzione dovrebbero essere eseguiti solo dapersonale qualificato. Il mancato rispetto delle raccoman-dazioni può causare morte o lesioni gravi.
AVVISOAVVIO INVOLONTARIO!Quando il convertitore di frequenza è collegato all'alimen-tazione di rete CA, il motore può avviarsi in qualsiasimomento. Il convertitore di frequenza, il motore e ogniapparecchiatura azionata devono essere pronti per ilfunzionamento. L'inosservanza può causare lesioni gravi omortali e danni alle apparecchiature o alla proprietà.
1. Confermare che la tensione in ingresso siabilanciata entro il 3%. In caso contrario,correggere lo squilibrio della tensione di ingressoprima di continuare. Ripetere questa proceduradopo aver corretto la tensione.
2. Assicurare che il cablaggio dell'apparecchiaturaopzionale, se presente, sia idoneo all'applicazione.
3. Assicurare che tutti gli interruttori di comando sitrovino in posizione Off. Gli sportelli del pannellodevono essere chiusi o il coperchio montato.
4. Alimentare l'unità. NON avviare il convertitore difrequenza per il momento. Per unità con unsezionatore, impostare sulla posizione On peralimentare il convertitore di frequenza.
4.3 Programmazione funzionale di base
I convertitori di frequenza richiedono una programmazionefunzionale di base per assicurare le migliori prestazioni difunzionamento. La programmazione funzionale di baserichiede l'immissione dei dati di targa del motore per ilmotore da utilizzare e le velocità del motore minima emassima. Immettere i dati in base alla seguente procedura.Le impostazioni dei parametri raccomandate sonoconcepite per scopi di avviamento e controllo. Leimpostazioni dell'applicazione possono variare.
Immettere i dati con il convertitore di frequenza acceso manon ancora in funzione.
1. Premere [Quick Menu] sull'tastiera.
2. Utilizzare i tasti di navigazione per passare adavviamento rapido e premere [OK].
3. Selezionare la lingua e premere [OK]. Quindiimmettere i dati motore nei parametri P-02, P-03,P-06, P-07, F-04 e F-05 (solo motori a induzione;per i motori a magneti permanenti per ora èpossibile tralasciare questi parametri). Questeinformazioni si trovano sulla targa del motore.L'intero menu rapido è mostrato in
P-07 Potenza motore [kW] o P-02 Potenzamotore [HP]
F-05 Tens. nom. mot.
F-04 Frequenza di base
P-03 Corrente motore
P-06 Velocità di base
4. Per F-07 Tempo accel 1 si consigliano 60 secondiper le ventole o 10 secondi per le pompe.
5. Per F-08 Tempo decel 1 si consigliano 60 secondiper le ventole o 10 secondi per le pompe.
6. Per F-10 immettere Sovracc. elettr. scatto 1 per laprotezione da sovraccarico classe 20. Per ulterioriinformazioni, vedere 3.4.1 Requisiti
7. Per F-16 Limite basso velocità motore [Hz]impostare i requisiti dell'applicazione. Se almomento questi valori sono ignoti, si consiglial'uso dei seguenti valori. Questi valori permettonoil funzionamento iniziale del convertitore difrequenza. Tuttavia, prendere tutte le precauzioninecessarie per impedire il danneggiamentodell'apparecchiatura. Assicurare che i valoriraccomandati siano sicuri per essere usati per ilcollaudo funzionale prima di avviare l'apparec-chiatura.
Ventola = 20Hz
Pompa = 20Hz
Compressore = 30Hz
8. In F-15 Limite alto velocità motore [Hz] immetterela frequenza motore da F-04 Frequenza di base.
Avviamento e test funzional... Guida rapida AF-600 FP
16 DET-759A/I
44
Questo conclude la procedura di messa a punto rapida.Premere [Status] per tornare al display funzionale.
In P-04 Auto Tune selezionare Taratura automatica ridotta oTaratura automatica completa e seguire le istruzioni aschermo. Vedere 4.4 Auto Tune
4.4 Auto Tune
Auto tune è una procedura di prova che misura le caratte-ristiche elettriche del motore per ottimizzare lacompatibilità tra il convertitore di frequenza e il motore.
• Il convertitore di frequenza costruisce un modellomatematico del motore per la regolazione dellacorrente motore in uscita. La procedura verificainoltre il bilanciamento delle fasi di ingressodell'alimentazione elettrica e confronta le caratte-ristiche del motore con i dati immessi in P-02,P-03, P-06, P-07, F-04 e F-05.
• Non determina il funzionamento del motore oeventuali danneggiamenti allo stesso
• Alcuni motori potrebbero non essere in grado dieseguire la versione completa del test. In quelcaso, selezionare Abilitare AMA ridotto
• Se al motore è collegato un filtro di uscita,selezionare Auto Tune ridotto
• In presenza di avvisi o allarmi, vedere 7 Avvisi eallarmi
4.5 Controllo rotazione motore
Prima di far funzionare il convertitore di frequenza,controllare la rotazione del motore. Il motore funzioneràbrevemente a 5 Hz o alla minima frequenza impostata inF-16 Limite basso velocità motore [Hz].
1. Premere due volte [Main Menu] sul tastierino.
2. Immettere la Configurazione dati parametrici escorrere a P-## Dati motore e premere [OK] peraccedere.
3. Passare a P-08 Controllo rotazione motore.
4. Premere [OK].
5. Passare a Abilita.
Apparirà il seguente testo: Nota! Il motore può girare nelladirezione sbagliata.
6. Premere [OK].
7. Seguire le istruzioni sullo schermo.
Per cambiare il senso di rotazione, togliere l'alimentazioneal convertitore di frequenza e attendere che la corrente siscarichi. Invertire il collegamento di due dei tre cavimotore sul lato motore oppure sul lato convertitore difrequenza del collegamento.
4.6 Test di controllo locale
ATTENZIONEAVVIAMENTO DEL MOTORE!Assicurarsi che motore, sistema e ogni apparecchiaturacollegata siano pronti per l'avviamento. È la responsabilitàdell'utente assicurare un funzionamento sicuro in tutte lecondizioni. Se il motore, il sistema e ogni apparecchiaturacollegata non sono pronti per l'avviamento potrebberoverificarsi danneggiamenti alle apparecchiature o lesionipersonali.
NOTA!Il tasto hand sull'tastiera fornisce un comando di avviolocale al convertitore di frequenza. Il tasto OFF fornisce lafunzione di arresto.Nel funzionamento in modalità locale, le frecce Su e Giùdell'tastiera aumentano e diminuiscono la velocità in uscitadel convertitore di frequenza. I tasti freccia Sinistra eDestra consentono di spostare il cursore del displaynumerico.
1. Premere [Hand].
2. Accelerare il convertitore di frequenza alla pienavelocità premendo []. Spostare il cursore asinistra della virgola decimale consente diapportare modifiche più velocemente.
3. Tenere conto di tutti i problemi di accelerazione.
4. Premere [OFF].
5. Tenere conto di tutti i problemi di decelerazione.
In presenza di problemi di accelerazione
• In presenza di avvisi o allarmi, vedere 7 Avvisi eallarmi
• Controllare che i dati del motore siano inseriticorrettamente
• Aumentare il tempo di accel. in F-07 Tempo accel1
• Aumentare il limite di corrente in F-43 Limitecorrente
• Aumentare il limite di coppia in F-40 Limitatore dicoppia (marcia)
Se si sono presentati problemi di decelerazione
• In presenza di avvisi o allarmi, vedere 7 Avvisi eallarmi
• Controllare che i dati del motore siano inseriticorrettamente
• Aumentare il tempo di decel. in F-08 Tempo decel1
Avviamento e test funzional... Guida rapida AF-600 FP
DET-759A/I 17
4 4
Vedere 7.1 Avvisi e allarmi per ripristinare il convertitore difrequenza dopo una corsa.
NOTA!Le sezioni da 4.1 Pre-avvio a 4.6 Test di controllo locale inquesto capitolo completano le procedure di alimentazionedel convertitore di frequenza, la programmazione, configu-razione di base, e il collaudo funzionale.
4.7 Avvio del sistema
La procedura in questa sezione richiede il completamentodel cablaggio da parte dell'utente e la programmazionedell'applicazione. ha lo scopo di semplificare questeoperazioni. Si consiglia la procedura seguente dopo ilcompletamento della configurazione dell'applicazione daparte dell'utente.
ATTENZIONEAVVIAMENTO DEL MOTORE!Assicurarsi che motore, sistema e ogni apparecchiaturacollegata siano pronti per l'avviamento. È la responsabilitàdell'utente assicurare un funzionamento sicuro in tutte lecondizioni di funzionamento. Se il motore, il sistema e ogniapparecchiatura collegata non sono pronti perl'avviamento potrebbero verificarsi danneggiamenti alleapparecchiature o lesioni personali.
1. Premere [Auto].
2. Assicura il corretto cablaggio delle funzioni dicontrollo esterno al convertitore di frequenza eche tutta la programmazione sia completata.
3. Applicare un comando di avvio esterno.
4. Regolare il riferimento di velocità nell'intervallo divelocità.
5. Togliere il comando di avvio esterno.
6. Annotare eventuali problemi.
In presenza di avvisi o allarmi, vedere 7 Avvisi e allarmi.
Avviamento e test funzional... Guida rapida AF-600 FP
18 DET-759A/I
44
5 Interfaccia utente
5.1 Tastierino
Il tastiera è la combinazione di display e tasti sulla parteanteriore dell'unità. L'tastiera è l'interfaccia utente per ilconvertitore di frequenza.
La tastiera ha diverse funzioni utente.
• Avvio, arresto e regolazione della velocità nellamodalità di comando locale
• Visualizzazione dei dati di funzionamento, stato,avvisi e avvertenze
• Programmazione delle funzioni del convertitore difrequenza
• Ripristinare manualmente il filtro attivo dopo unguasto quando è inattivo l'autoripristino
NOTA!Il contrasto del display può essere regolato premendo[STATUS] e il tasto Su/Giù.
5.1.1 Tastiera Layout
L'tastiera è suddiviso in quattro gruppi funzionali (vediDisegno 5.1).
Disegno 5.1 Tastiera
a. Area di visualizzazione.
b. I tasti del menu display consentono di modificarela visualizzazione per mostrare opzioni di stato,programmazione e cronologia dei messaggi dierrore.
c. I tasti di navigazione consentono di programmarefunzioni, spostare il cursore dei display e regolarela velocità nel funzionamento in modalità locale.Sono presenti anche indicatori di stato.
d. Tasti per il modo di funzionamento e ripristino.
Interfaccia utente Guida rapida AF-600 FP
DET-759A/I 19
5 5
5.1.2 Impostazione Tastiera dei valori suldisplay
L'area del display è attivata quando il convertitore difrequenza riceve alimentazione dalla tensione di rete, daun terminale del bus CC o da un'alimentazione esterna a24 V.
Le informazioni visualizzate sull'tastiera sono personaliz-zabili per l'applicazione dell'utente.
• Ogni visualizzazione del display ha un parametroassociato.
• Le opzioni vengono selezionate nel menuConfigurazione tastierino.
• Il display 2 presenta un'opzione di visualizzazioneingrandita.
• Lo stato del convertitore di frequenza nell'ultimariga del display viene generato automaticamentee non è selezionabile.
Display Numero del
parametro
Impostazione di default
1.1 K-20 Giri/minuto del motore
1.2 K-21 Corrente motore
1.3 K-22 Potenza motore (kW)
2 K-23 Frequenza motore
3 K-24 Riferimento in percentuale
5.1.3 Tasti menu di visualizzazione
I tasti menu sono utilizzati per l'impostazione dei parametridi accesso menu, per passare tra le varie modalità divisualizzazione dello stato durante il normale funzio-namento e per la visualizzazione dei dati del log guasti.
Tasto FunzioneStato Premere per visualizzare le informazioni sul
funzionamento.
• In modalità Automatica, premere e tenerepremuto per passare alle diverse visualiz-zazioni dello stato
• Premere ripetutamente per esplorare tuttele visualizzazioni di stato
• Premere e tenere premuto [Status] più [] o
[] per regolare la luminosità del display
• Il simbolo nell'angolo in alto a destra deldisplay mostra il verso di rotazione delmotore e il setup attivo. Questo non èprogrammabile.
Menu rapido Permette di accedere ai parametri di program-mazione necessari per le istruzioni diconfigurazione iniziale e molte istruzionidettagliate relative all'applicazione.
• Premere per accedere a Avviamento rapidoper istruzioni passo passo per programmarela configurazione di base del controllore infrequenza
• Premere per accedere a Macro ventole,Macro pompe, Macro compressori o Anellochiuso per istruzioni passo passo relative alleapplicazioni del programma
• Premere per accedere a Tendenza per laregistrazione in tempo reale sul display del
tastierino.
• Premere per accedere a Controllo datiparametrici per modifiche nel set di datiparametrici.
• Seguire la sequenza dei parametri comepresentata per la configurazione dellefunzioni
Menu
principale
Permette di accedere a tutti i parametri di
programmazione.
• Premere due volte per accedere all'indice dilivello superiore
• Premere una volta per tornare all'ultimopunto di accesso
• Premere e tenere premuto per immettereun numero di parametro per accederedirettamente a quel parametro
Log allarme Visualizza un elenco di avvisi correnti, gli ultimi10 allarmi e il log di manutenzione.
• Per dettagli sul convertitore di frequenzaprima che entri nella modalità di allarme,selezionare il numero di allarme usando itasti di navigazione e premere [OK].
Interfaccia utente Guida rapida AF-600 FP
20 DET-759A/I
55
5.1.4 Tasti di navigazione
I tasti di navigazione sono utilizzati per le funzioni diprogrammazione e per spostare il cursore del display. Itasti di navigazione permettono inoltre la regolazione divelocità nel funzionamento locale (manuale). In questa areasono presenti anche tre indicatori di stato del convertitoredi frequenza.
Tasto FunzioneIndietro Consente di tornare al passo e all'elenco
precedente nella struttura del menu.
Annulla Annulla l'ultima modifica o l'ultimo comando,sempre che la modalità di visualizzazione non siastata cambiata.
Info Premere per la definizione della funzionevisualizzata.
Tasti di
navigazione
Utilizzare i quattro tasti (frecce) di navigazione per
spostarsi tra le voci del menu.
OK Utilizzato per accedere ai gruppi di parametri o perabilitare una selezione.
Luce Indicatore Funzione
Verde ON La luce ON si attiva quando ilconvertitore di frequenza vienealimentato dalla tensione di rete,un terminale bus CC o un alimen-tatore esterno da 24 V.
Giallo AVV. Quando sono soddisfatte le
condizioni per l'avviso, si accendela spia gialla WARN e sul displayappare il testo che spiega il
problema.
Rosso ALLARME Una condizione di guasto causa il
lampeggiare della spia rossa diallarme e la visualizzazione deltesto di allarme.
5.1.5 Tasti di navigazione
I tasti di comando si trovano nella parte inferioredell'tastiera.
Tasto Funzione
Man. Premere per avviare il convertitore di frequenza
nel controllo locale.
• Utilizzare i tasti di navigazione per regolare lavelocità del convertitore di frequenza
• Un segnale di arresto esterno dall'ingresso dicomando o dalla comunicazione serialeesclude il comando locale
Off Arresta il motore ma non rimuove l'alimentazioneal convertitore di frequenza.
Auto Pone il sistema in modalità di funzionamento
remoto.
• Risponde a un comando di avvio esterno daimorsetti di comando o dalla comunicazione
seriale
• Il riferimento di velocità proviene da unasorgente esterna
Ripristino Ripristina manualmente il convertitore di
frequenza dopo aver eliminato un guasto.
5.2 Salvare e copiare le impostazioni deiparametri
I dati di programmazione sono memorizzati internamenteal convertitore di frequenza.
• I dati possono essere caricati nella memoriatastiera per il backup.
• Una volta archiviati nell'tastiera, i dati possonoessere scaricati nuovamente nel convertitore difrequenza
• I dati possono essere anche scaricati in altriconvertitori di frequenza collegando l'tastiera aquesti ultimi e scaricando le impostazionimemorizzate. (Questo è un modo rapido perprogrammare varie unita con le stesseimpostazioni.)
Interfaccia utente Guida rapida AF-600 FP
DET-759A/I 21
5 5
• L'inizializzazione del convertitore di frequenza perripristinare le impostazioni di fabbrica nonmodifica i dati memorizzati nella memoriadell'tastiera
AVVISOAVVIO INVOLONTARIO!Quando il convertitore di frequenza è collegato all'alimen-tazione di rete CA, il motore può avviarsi in qualsiasimomento. Il convertitore di frequenza, il motore e ogniapparecchiatura azionata devono essere pronti per ilfunzionamento. L'inosservanza può causare lesioni gravi omortali e danni alle apparecchiature o alla proprietà.
5.2.1 Caricamento di dati nell'tastiera
1. Premere [OFF] per arrestare il motore prima dicaricare o scaricare dati.
2. Vai a K-50 Copia tastiera.
3. Premere [OK].
4. Selezionare Tutti a tastiera.
5. Premere [OK]. Una barra di avanzamento mostralo stato del caricamento.
6. Premere [Hand] o [Auto] per ritornare al funzio-namento normale.
5.2.2 Scaricare dati dall'tastiera
1. Premere [OFF] per arrestare il motore prima dicaricare o scaricare dati.
2. Vai a K-50 Copia tastiera.
3. Premere [OK].
4. Selezionare Tutti da tastiera.
5. Premere [OK]. Una barra di avanzamento mostrail processo di scaricamento.
6. Premere [Hand] o [Auto] per ritornare al funzio-namento normale.
5.3 Ripristino delle impostazioni di fabbrica
ATTENZIONEL'inizializzazione riporta l'unità alle impostazioni di fabbrica.Ogni dato relativo a programmazione, dati motore, localiz-zazione e monitoraggio andrà perso. Il caricamento di datinell'tastiera consente di effettuare un backup prima dell'ini-zializzazione.
Il ripristino delle impostazioni di fabbrica dei parametri delconvertitore di frequenza avviene mediante l'inizializ-zazione del convertitore di frequenza. L'inizializzazione può
avvenire mediante H-03 Ripr. imp. di fabbrica omanualmente.
• L'inizializzazione mediante H-03 Ripr. imp. difabbrica non modifica dati del convertitore difrequenza quali ore di esercizio, selezioni dellacomunicazione seriale, impostazioni persona-lizzate del menu, log guasti, , log allarmi e altrefunzioni di monitoraggio
• In genere si consiglia l'utilizzo di H-03 Ripr. imp. difabbrica
• L'inizializzazione manuale cancella tutti i dati dimotore, programmazione, localizzazione emonitoraggio e ripristina le impostazioni difabbrica
5.3.1 Inizializzazione consigliata
1. Premere [Main Menu] due volte per accedere aiparametri.
2. Passare a H-03 Ripr. imp. di fabbrica.
3. Premere [OK].
4. Scorrere a [2] Ripristino delle impostazioni difabbrica.
5. Premere [OK].
6. Togliere l'alimentazione all'unità e attendere cheil display si spenga.
7. Alimentare l'unità.
Durante l'avvio avviene il ripristino delle impostazionipredefinite dei parametri. Questo può richiedere un tempoleggermente più lungo del normale.
8. Viene visualizzato l'allarme 80.
9. Premere [Reset] per ritornare al funzionamentonormale.
5.3.2 Inizializzazione manuale
1. Togliere l'alimentazione all'unità e attendere cheil display si spenga.
2. Tenere premuti contemporaneamente [Status] -[Main Menu] - [OK] e alimentare l'unità.
All'avvio vengono ripristinate le impostazioni predefinite difabbrica dei parametri. Questo può richiedere un tempoleggermente più lungo del normale.
L'inizializzazione manuale non ripristina le seguentiinformazioni sul convertitore di frequenza
• ID-00 Ore di funzionamento
• ID-03 Accensioni
Interfaccia utente Guida rapida AF-600 FP
22 DET-759A/I
55
• ID-04 Sovratemp.
• ID-05 Sovratensioni
Interfaccia utente Guida rapida AF-600 FP
DET-759A/I 23
5 5
6.1.1 Struttura del menu principaleK-
## C
onfig
uraz
ione
del
tas
tierin
oK-
37 T
esto
dis
play
1K-
8# G
iorn
i e v
isua
l. da
ta/o
raF-
2# F
onda
men
tale
2E-
## I/
O d
igita
li
K-0#
Impo
st.d
i bas
e ta
stie
rino
K-38
Tes
to d
ispl
ay 2
K-81
Gio
rni f
eria
liF-
24 T
empo
di m
ante
nim
ento
E-0#
Ingr
essi
dig
itali
K-01
Lin
gua
K-39
Tes
to d
ispl
ay 3
K-82
Gio
rni f
eria
li ag
giun
tivi
F-26
Rum
. mot
. (fr
eq. p
ort.)
E-00
Mod
o I/
O d
igita
le
K-02
Uni
tà v
eloc
ità m
otor
eK-
4# T
asti
del
la t
astie
raK-
83 G
iorn
i fes
tivi a
ggiu
ntiv
iF-
27 T
ono
mot
ore
casu
ale
E-01
Ingr
. dig
itale
mor
sett
o 1
8
K-03
Impo
staz
ioni
loca
liK-
40 P
ulsa
nte
[Han
d] s
ul ta
stie
rino
K-89
Vis
ual.
data
e o
raF-
3# F
onda
men
tale
3E-
02 In
gr. d
igita
le m
orse
tto
19
K-04
Sta
to d
i fun
z. a
ll'ac
cens
.K-
41 P
ulsa
nte
[Off]
sul
tast
ierin
oF-
## P
aram
etri
fond
amen
tali
F-37
Mod
ello
di c
omm
utaz
. ava
nz.
E-03
Ingr
. dig
itale
mor
sett
o 2
7
K-05
Uni
tà m
odo
loca
leK-
42 P
ulsa
nte
[Aut
o] s
ul t
astie
rino
F-0#
Fon
dam
enta
le 0
F-38
Sov
ram
odul
azio
neE-
04 In
gr. d
igita
le m
orse
tto
29
K-1#
Ope
razi
oni d
i con
figur
azio
ne d
elta
stie
rino
K-43
Pul
sant
e [R
eset
] su
l tas
tierin
oF-
01 Im
post
azio
ne fr
eque
nza
1F-
4# F
onda
men
tale
4E-
05 In
gr. d
igita
le m
orse
tto
32
K-10
Set
up a
ttiv
oK-
5# C
opia
/Sal
vaF-
02 M
etod
o d
i fun
zion
amen
toF-
40 L
imita
tore
di c
oppi
a (m
arci
a)E-
06 In
gr. d
igita
le m
orse
tto
33
K-11
Mod
ifica
set
upK-
50 C
opia
tas
tiera
F-03
Fre
q. d
i usc
ita m
ax 1
F-41
Lim
itato
re d
i cop
pia
(fren
atur
a)
E-1#
Ram
pe d
i acc
eler
azio
ne/d
ecel
e-
razi
one
supp
lem
enta
ri
K-12
Que
sto
set
up c
olle
gato
aK-
51 C
opia
set
upF-
04 F
requ
enza
di b
ase
F-43
Lim
ite c
orre
nte
E-10
Tem
po a
ccel
2
K-13
Vis
ualiz
zazi
one:
Set
up c
olle
gati
K-6#
Pro
tezi
one
pass
wor
dF-
05 T
ens.
nom
. mot
.F-
5# R
iferim
enti
est
esi
E-11
Tem
po d
ecel
2
K-14
Vis
ualiz
zazi
one:
Edi
ta s
etup
/ca
nale
K-60
Pas
sw. m
enu
prin
c.F-
07 T
empo
acc
el 1
F-52
Rife
rimen
to m
inim
oE-
2# U
scite
dig
itali
K-2#
Dis
play
del
tas
tierin
o
K-61
Acc
esso
al m
enu
prin
c. s
enza
pass
w.
F-08
Tem
po d
ecel
1F-
53 R
iferim
ento
mas
sim
oE-
20 U
scita
dig
. mor
sett
o 2
7
K-20
Vis
ualiz
. rid
. dis
play
riga
1.1
K-65
Pas
swor
d m
enu
rap
ido
F-1#
Fon
dam
enta
le 1
F-54
Fun
zion
e di
rife
rimen
toE-
21 U
scita
dig
. mor
sett
o 2
9
K-21
Vis
ualiz
.rido
tta
del d
ispl
ay-
riga
1.2
K-66
Acc
esso
al m
enu
rapi
do s
enza
pass
wor
dF-
10 S
ovra
ccar
ico
ele
ttro
nico
F-6#
Rife
rimen
tiE-
24 F
unzi
one
relè
K-22
Vis
ualiz
.rido
tta
del d
ispl
ay-
riga
1,3
K-7#
Impo
staz
ioni
del
l'oro
logi
oF-
11 V
entil
az. e
st. m
otor
eF-
64 R
if. r
elat
ivo
pre
impo
stat
oE-
26 R
itard
o a
ttiv
., re
lè
K-23
Vis
ualiz
z. e
stes
a de
l dis
play
rig
a 2
K-70
Dat
a e
ora
F-12
Ingr
esso
ter
mis
tore
mot
ore
F-9#
Pot
.met
ro d
ig.
E-27
Rita
rdo
dis
att.,
relè
K-24
Vis
ual.
com
plet
a de
l dis
play
-rig
a 3
K-71
For
mat
o d
ata
F-15
Lim
ite a
lto v
eloc
itàm
otor
e [H
z]F-
90 D
imen
sion
e pa
sso
E-5#
Mod
alità
I/O
/ I/
O s
uppl
emen
tare
K-25
Avv
iam
ento
rap
ido
K-72
For
mat
o d
ell'o
ra
F-16
Lim
ite b
asso
vel
ocità
mot
ore
[Hz]
F-91
Tem
po a
ccel
/dec
elE-
51 M
odo
Mor
sett
o 2
7
K-3#
Vis
ual.
pers
onal
iz. t
astie
rino
K-74
DST
/ora
lega
le
F-17
Lim
. alto
vel
. mot
ore
[giri
/
min
]F-
92 R
ipris
tino
del
la p
oten
zaE-
52 M
odo
mor
sett
o 2
9
K-30
Uni
tà p
er la
vis
ualiz
z. p
erso
n.K-
76 D
ST/a
vvio
ora
lega
leF-
18 L
im. b
asso
vel
. mot
ore
[giri
/min
]F-
93 L
imite
mas
sim
oE-
53 In
gr. d
igita
le m
orse
tto
X30
/2
K-31
Val
ore
min
. del
la v
isua
l. pe
rson
.K-
77 D
ST/f
ine
ora
lega
le
F-94
Lim
ite m
inim
oE-
54 In
gr. d
igita
le m
orse
tto
X30
/3
K-32
Val
ore
max
del
la v
isua
l. pe
rson
.K-
79 E
rror
e or
olog
io
F-95
Rita
rdo
ram
pa d
i acc
./dec
el.
E-55
Ingr
. dig
itale
mor
sett
o X
30/4
Informazioni sulla programm... Guida rapida AF-600 FP
24 DET-759A/I
66
E-56
Usc
ita d
ig. m
ors.
X30
/6 (O
PCG
PIO
)E-
96 P
reim
p. ti
meo
ut u
scita
impu
lsi
#29
P-07
Pot
enza
mot
ore
[kW
]H
-5#
Impo
s.ind
ip. d
al c
aric
oA
N-1
# In
gres
so a
nalo
gico
53
E-57
Usc
ita d
ig. m
ors.
X30
/7 (O
PCG
PIO
)E-
97 C
ontr
ollo
bus
usc
ita im
puls
i#X
30/6
P-08
Con
trol
lo r
otaz
ione
mot
ore
H-5
8 Im
puls
i cor
r. te
st ri
agg.
al v
olo
AN
-10
Tens
. bas
sa m
orse
tto
53
E-6#
Ingr
. im
puls
iE-
98 P
reim
p. ti
meo
ut u
scita
impu
lsi
#X30
/6P-
09 C
ompe
ns. s
corr
im.
H-5
9 Fr
eq. i
mp.
tes
t ria
gg. v
olo
AN
-11
Tens
ione
alta
mor
sett
o 5
3
E-60
Fre
quen
za b
assa
mor
sett
o 2
9
C-##
Fun
zion
i per
il c
ontr
ollo
del
la
freq
uenz
a
P-10
Cos
tant
e di
tem
po c
ompe
ns.
scor
rim.
H-6
# Im
post
azio
ne d
ipen
d. d
al c
aric
oA
N-1
2 Co
rr. b
assa
mor
sett
o 5
3
E-61
Fre
quen
za a
lta m
ors.
29
C-0#
Fun
zion
i per
il c
ontr
ollo
del
lafr
eque
nza
P-3#
Dat
i mot
ore
avan
z.H
-64
Smor
zam
ento
riso
nanz
aA
N-1
3 Co
rren
te a
lta m
orse
tto
53
E-62
Rif.
bas
so/v
al. r
etro
az. m
orse
tto
29
C-01
Fre
quen
za d
i sal
to d
a [H
z]P-
30 R
esis
tenz
a di
sta
tore
(Rs)
H-6
5 Sm
orza
men
to ri
s. t
empo
cos
tant
eA
N-1
4 Ri
f.bas
so/v
al.re
troa
z.m
orse
tto
53
E-63
Rif.
alto
/val
. ret
roaz
. mor
sett
o 2
9C-
02 V
eloc
ità d
i mov
imen
to d
a [g
iri/
min
]P-
31 R
esis
tenz
a ro
tore
(Rr)
H-7
# A
vvis
i im
post
abili
AN
-15
Rif.
alto
/val
ore
retr
oaz.
mor
sett
o53
E-64
Cos
tant
e di
tem
po d
el fi
ltro
impu
lsi #
29C-
03 V
eloc
ità d
i mov
imen
to a
[giri
/m
in]
P-35
Rea
ttan
za p
rinci
pale
(Xh)
H-7
0 A
vvis
o c
orre
nte
bass
aA
N-1
6 Co
stan
te d
i tem
po fi
ltro
mor
s.53
E-65
Fre
quen
za b
assa
mor
sett
o 3
3C-
04 F
requ
enza
di m
ovim
ento
a [H
z]P-
36 R
esis
t. p
erdi
te fe
rro
(Rfe
)H
-71
Avv
iso
cor
rent
e al
taA
N-1
7 Te
nsio
ne z
ero
mor
s. 5
3
E-66
Fre
quen
za a
lta m
ors.
33
C-05
Fre
q. d
i usc
ita m
ulti
fase
1 -
8H
-##
Para
met
ri H
igh
Per
fH
-72
Avv
iso
vel
ocità
bas
saA
N-2
# In
gres
so a
nalo
gico
54
E-67
Rif.
bas
so/v
al. r
etro
az. m
orse
tto
33
C-2#
Set
up jo
gH
-0#
Ope
razi
oni H
igh
Per
fH
-73
Avv
iso
vel
ocità
alta
AN
-20
Tens
. bas
sa m
orse
tto
54
E-68
Rif.
alto
/val
. ret
roaz
. mor
sett
o 3
3C-
20 V
eloc
ità m
arci
a jo
g [H
z]H
-03
Ripr
. im
p. d
i fab
bric
aH
-74
Avv
iso
rif.
bas
soA
N-2
1 Te
nsio
ne a
lta m
orse
tto
54
E-69
Cos
tant
e di
tem
po d
el fi
ltro
impu
lsi #
33C-
21 V
eloc
ità m
arci
a jo
g [R
PM]
H-0
4 Ri
pris
tino
aut
omat
ico
(tem
pi)
H-7
5 A
vvis
o r
iferim
ento
alto
AN
-22
Corr
. bas
sa m
orse
tto
54
E-7#
Usc
ita im
puls
iC-
22 T
empo
acc
el/d
ecel
mar
cia
jog
H-0
5 Ri
pris
t. au
t. (in
terv
. di r
eset
)H
-76
Avv
iso
ret
roaz
ione
bas
saA
N-2
3 Co
rren
te a
lta m
orse
tto
54
E-70
Usc
ita im
puls
i var
iabi
le m
orse
tto
27C-
3# Im
post
azio
ne d
i fre
quen
za 2
e 3
H-0
6 Fu
nzio
nam
ento
ven
tola
H-7
7 A
vvis
o r
etro
azio
ne a
ltaA
N-2
4 Ri
f.bas
so/v
al.re
troa
z.m
orse
tto
54
E-71
Fre
q. m
ax. u
scita
impu
lsi #
27C-
30 C
oman
do d
i fre
quen
za 2
H-0
8 Bl
occa
ggio
inve
rtito
H-7
8 Fu
nzio
ne fa
se m
otor
e m
anca
nte
AN
-25
Rif.
alto
/val
ore
retr
oaz.
mor
sett
o54
E-72
Usc
ita im
puls
i var
iabi
le m
orse
tto
29C-
34 C
oman
do d
i fre
quen
za 3
H-0
9 M
od. a
vvio
H-8
# A
datt
am. a
rres
toA
N-2
6 Co
stan
te d
i tem
po fi
ltro
mor
s.54
E-74
Fre
q. m
ax. u
scita
impu
lsi #
29C-
4# S
etup
freq
. di s
alto
sem
iaut
om.
H-3
# Ve
loci
tà d
i arr
esto
H-8
0 Fu
nzio
ne a
ll'ar
rest
oA
N-2
7 Te
nsio
ne z
ero
mor
s. 5
4
E-75
Usc
ita im
p. v
ar. m
orse
tto
X30
/6C-
40 S
etup
freq
. sal
to s
emia
ut.
H-3
6 Ve
loci
tà m
edia
bas
sa [g
iri/m
in]
H-8
1 Ve
l.min
. per
funz
.all'
arre
sto
[RPM
]A
N-3
# In
gres
so a
nalo
gico
X30
/11
E-76
Fre
q. m
ax. u
scita
impu
lsi #
X30/
6P-
## D
ati m
otor
eH
-37
Velo
cità
med
ia b
assa
[Hz]
H-8
2 Ve
l.min
. per
funz
.all'
arre
sto
[Hz]
AN
-30
Val.
di te
ns. b
assa
mor
s. X
30/1
1
E-9#
Con
trol
lato
da
bus
P-0#
Dat
i mot
ore
H-4
# Im
post
azio
ni a
vanz
ate
AN
-##
I/O a
nalo
gici
AN
-31
Val.
tens
ione
alta
mor
s. X
30/1
1
E-90
Con
trol
lo b
us d
igita
le e
a re
lèP-
02 P
oten
za m
otor
e [H
P]H
-40
Mod
o c
onfig
uraz
ione
AN
-0#
Mod
. I/O
ana
logi
coA
N-3
4 Va
l. rif
./ret
r. ba
sso
mor
s. X
30/1
1
E-93
Con
trol
lo b
us u
scita
impu
lsi #
27P-
03 C
orre
nte
mot
ore
H-4
3 Ca
ratt
eris
tiche
di c
oppi
aA
N-0
0 Te
mpo
tim
eout
ten
sion
e ze
roA
N-3
5 Va
l. rif
./ret
r. al
to m
ors.
X30
/11
E-94
Pre
imp.
tim
eout
usc
ita im
puls
i#2
7P-
04 A
uto
Tun
eH
-48
Sens
o o
rario
AN
-01
Funz
. tem
poriz
z. t
ensi
one
zero
AN
-36
Cost
ante
di t
empo
filtr
o m
ors.
X30/
11
E-95
Con
trol
lo b
us u
scita
impu
lsi #
29P-
06 V
eloc
ità d
i bas
e
AN
-02
Funz
. tim
eout
tens
. zer
o F
ireM
ode
AN
-37
Corr
ente
zer
o m
ors.
X30
/11
Informazioni sulla programm... Guida rapida AF-600 FP
DET-759A/I 25
6 6
AN
-4#
Ingr
esso
ana
logi
co X
30/1
2SP
-##
Funz
ioni
spe
cial
iSP
-5#
Am
bien
teO
-13
Paro
la d
i sta
to c
onfig
urab
ile(S
TW)
O-8
# D
iagn
ostic
a po
rta
FC
AN
-40
Val.
tens
. bas
sa m
orse
tto
X30
/12
SP-1
# Li
nea
On/
Off
SP-5
0 Fi
ltro
RFI
O-3
# Im
post
az. p
orta
con
v. d
i fre
q.O
-80
Cont
eggi
o m
essa
ggi b
us
AN
-41
Val.
tens
. alta
mor
sett
o X
30/1
2SP
-10
Gua
sto
line
aSP
-51
Com
pens
azio
ne b
us C
CO
-30
Prot
ocol
loO
-81
Cont
eggi
o e
rror
i bus
AN
-44
Val.
rif./r
etr.
bass
o m
ors.
X30
/12
SP-1
1 Te
nsio
ne d
i lin
ea c
on g
uast
o in
ingr
esso
SP-5
3 M
onito
r. ve
ntol
aO
-31
Indi
rizzo
O-8
2 Co
nteg
gio
mes
sagg
i sla
ve
AN
-45
Val.
rif./r
etr.
alto
mor
s. X
30/1
2SP
-12
Funz
. dur
ante
sbi
lanc
iam
ento
di l
inea
SP-5
5 Fi
ltro
di u
scita
O-3
2 Ba
ud ra
te p
orta
con
v. d
i
freq
.O
-83
Cont
eggi
o e
rror
i sla
ve
AN
-46
Cost
ante
di t
empo
filtr
o m
ors.
X30/
12SP
-2#
Funz
ioni
di r
ipris
tino
SP-5
9 N
umer
o e
ffett
ivo
di u
nità
inve
rter
O-3
3 Pa
rità
port
a co
nv. d
i fre
q.O
-89
Cont
. dia
gnos
tica
AN
-47
Corr
ente
zer
o m
ors.
X30
/12
SP-2
3 Im
p. c
odic
e tip
oSP
-6#
Dec
lass
amen
to a
utom
atic
oO
-34
Dur
ata
del c
iclo
stim
ata
O-9
# Bu
s Jo
g /
retr
oazi
one
AN
-5#
Usc
ita a
nalo
gica
42
SP-2
5 Ri
tard
o s
catt
o a
l lim
ite d
i cop
pia
SP-6
0 Fu
nzio
ne s
ovra
tem
pera
tura
O-3
5 Ri
tard
o m
inim
o r
ispo
sta
O-9
0 Ve
loci
tà b
us jo
g 1
AN
-50
Usc
ita m
orse
tto
42
SP-2
6 Ri
tard
o s
catt
o p
er g
uast
o c
onv.
di
freq
.SP
-61
Funz
. con
sov
racc
. c. d
i fre
q.O
-36
Rita
rdo
max
. ris
post
aO
-91
Velo
cità
bus
jog
2
AN
-51
Mor
s. 4
2, u
sc. s
cala
min
.SP
-28
Impo
staz
. pro
duz.
SP-6
2 D
ecl.
corr
. sov
racc
. con
v.
freq
.O
-37
Rita
rdo
max
. int
erca
r.O
-94
Retr
oazi
one
bus
1
AN
-52
Mor
s. 4
2, u
sc. s
cala
max
.SP
-29
Cod.
di s
erv.
O-#
# O
pzio
ni/c
om.
O-4
# Im
p. p
rot.
MC
O-9
5 Re
troa
zion
e bu
s 2
AN
-53
Mor
sett
o 4
2, u
scita
con
trol
lata
via
bus
SP-3
# Re
g. li
m. d
i cor
r.O
-0#I
mpo
st.g
ener
.O
-40
Sele
zion
e te
legr
amm
aO
-96
Retr
oazi
one
bus
3
AN
-54
Mor
s. 4
2 Pr
eim
p. t
imeo
ut u
scita
SP-3
0 Re
g. li
m. c
orr.,
gua
dagn
o p
ropo
rz.
O-0
1 Si
to d
i com
ando
O-4
2 Co
nfig
. scr
ittur
a PC
DA
O-#
# O
pzio
ni I/
O a
nalo
gici
AN
-6#
Usc
ita a
nalo
gica
X30
/8SP
-31
Reg.
lim
. cor
r. , t
empo
inte
graz
.O
-02
Font
e pa
rola
di c
ontr
ollo
O-4
3 Co
nfig
. let
tura
PCD
AO
-0#
Mod
. I/O
ana
logi
ci
AN
-60
Usc
ita m
orse
tto
X30
/8SP
-32
Cont
r. lim
. cor
r. , t
empo
filtr
oO
-03
Tem
po t
imeo
ut p
arol
a di
cont
rollo
O-5
# D
igita
le/B
usA
O-0
0 M
odal
ità m
ors.
X42
/1
AN
-61
Mor
s. X
30/8
, sca
la m
axSP
-4#
Risp
arm
io e
nerg
etic
o
O-0
4 Fu
nzio
ne t
empo
rizz.
par
ola
di c
ontr
ollo
O-5
0 Se
lezi
one
ruot
a lib
era
AO
-01
Mod
alità
mor
s. X
42/3
AN
-62
Mor
sett
o X
30/8
, sca
la m
axSP
-40
Live
llo V
TO
-05
Funz
. fin
e te
mpo
rizza
zion
eO
-52
Sele
z. fr
eno
CC
AO
-02
Mod
alità
mor
s. X
42/5
AN
-63
Mor
s. X
30/8
, usc
ita c
ontr
olla
ta v
iabu
sSP
-41
Risp
arm
i ene
rget
ici m
agne
tizz.
min
.O
-06
Ripr
ist.
tem
por.
par
ola
dico
ntr.
O-5
3 Se
lez.
avv
ioA
O-1
# In
gres
so a
nalo
gico
X42
/1
AN
-64
Prei
mp.
tim
eout
usc
ita m
ors.
X30/
8SP
-42
Freq
uenz
a m
in. r
ispa
rmio
ene
rget
ico
O-0
7 D
iagn
osi t
rigge
rO
-54
Sele
z. in
vers
ione
AO
-10
Tens
. bas
sa m
orse
tto
X42
/1
SP
-43
Cosp
hi m
otor
eO
-1#
Impo
staz
ioni
di c
ontr
ollo
O-5
5 Se
lez.
set
upA
O-1
1 Te
nsio
ne a
lta m
ors.
X42
/1
O-1
0 Pr
ofilo
par
ola
di c
om.
O-5
6 Se
lezi
one
rif. p
reim
post
ato
AO
-14
Val.
rif./r
etr.
bass
o m
ors.
X42
/1
Informazioni sulla programm... Guida rapida AF-600 FP
26 DET-759A/I
66
AO
-15
Val.
rif./r
etr.
alto
mor
s. X
42/1
AO
-6#
Usc
ita a
nalo
gica
X42
/11
PB-9
4 Pa
ram
etri
cam
biat
i (5)
EN-3
3 Re
visi
one
CIP
BN-7
3 Fr
ame
di in
form
. max
. MS/
TP
AO
-16
Cost
ante
di t
empo
filtr
o m
ors.
X42/
1A
O-6
0 U
scita
mor
sett
o X
42/1
1EN
-##
Ethe
rnet
EN-3
4 Co
dice
pro
dott
o C
IPBN
-74
"Sta
rtup
I am
"
AO
-17
Corr
ente
zer
o m
ors.
X42
/1A
O-6
1 M
orse
tto
X42
/11,
sca
la m
in.
EN-0
# Im
post
azio
ni IP
EN-8
# A
ltri s
ervi
zi E
ther
net
BN-7
5 Pa
ssw
ord
di i
nizi
aliz
zazi
one
AO
-2#
Ingr
esso
ana
logi
co X
42/3
AO
-62
Mor
s. X
42/1
1, s
cala
mas
sim
aEN
-00
Ass
egna
zion
e in
diriz
zo IP
EN-8
0 Se
rver
FTP
DN
-##
Bus
di c
ampo
Dev
iceN
et
AO
-21
Tens
ione
alta
mor
sett
o X
42/3
AO
-63
Mor
s. X
42/1
1, c
ontr
olla
to v
ia b
usEN
-01
Indi
rizzo
IPEN
-81
Serv
er H
TTP
DN
-0#
Impo
staz
. di b
ase
AO
-21
Tens
ione
alta
mor
sett
o X
42/3
AO
-64
Prei
mp.
tim
eout
mor
s. X
42/1
1EN
-02
Subn
et m
ask
EN-8
2 Se
rviz
io S
MTP
DN
-00
Prot
ocol
lo D
evic
eNet
AO
-24
Val.
rif./r
etr.
bass
o m
ors.
X42
/3PB
-##
Prof
ibus
EN-0
3 G
atew
ay d
efau
ltEN
-89
Port
a ca
nale
a p
resa
tras
pare
nte
DN
-01
Sele
z. b
aud
rate
AO
-25
Val.
rif./r
etr.
alto
mor
s. X
42/3
PB-1
5 Co
nfig
. scr
ittur
a PC
DEN
-04
Serv
er D
HCP
EN-9
# Se
rviz
i Eth
erne
t av
anza
tiD
N-0
2 M
AC
ID
AO
-26
Cost
ante
di t
empo
filtr
o m
ors.
X42/
3PB
-16
Conf
ig. l
ettu
ra P
CDEN
-05
Scad
enza
rila
scio
EN-9
0 D
iagn
osi c
avo
DN
-05
Visu
al. c
onta
tore
err
ori
tras
mis
sion
e
AO
-27
Corr
ente
zer
o m
ors.
X42
/3PB
-18
Indi
rizzo
nod
oEN
-06
Nam
e-se
rver
sEN
-91
MD
I-XD
N-0
6 Vi
sual
. con
tato
re e
rror
i ric
ezio
ne
AO
-3#
Ingr
esso
ana
logi
co X
42/5
PB-2
2 Se
lezi
one
tele
gram
ma
EN-0
7 N
ome
dom
inio
EN-9
2 IG
MP
Snoo
ping
DN
-07
Visu
al. c
onta
tore
bus
off
AO
-30
Tens
. bas
sa m
orse
tto
X42
/5PB
-23
Para
met
ri p
er s
egna
liEN
-08
Nom
e di
hos
tEN
-93
Lung
hezz
a er
rore
cav
oD
N-1
# D
evic
eNet
AO
-31
Tens
ione
alta
mor
s. X
42/5
PB-2
7 Pa
ram
. edi
t.EN
-09
Indi
rizzo
fisi
coEN
-94
Prot
ezio
ne B
road
cast
Stor
mD
N-1
0 Se
lez.
tip
o d
ati d
i pro
cess
o
AO
-34
Val.
rif./r
etr.
bass
o m
ors.
X42
/5PB
-28
Cont
rollo
di p
roce
sso
EN-1
# Pa
r. co
lleg.
Eth
erne
t
EN-9
5 Fi
ltro
di p
rote
zion
e
Broa
dcas
t St
orm
DN
-11
Dat
i pro
cess
o s
critt
ura
conf
ig.
AO
-35
Val.
rif./r
etr.
alto
mor
s. 4
2/5
PB-5
3 A
vvis
o d
i com
unic
azio
ne P
rofib
usEN
-10
Stat
o d
el c
olle
gam
ento
EN-9
8 Co
ntat
ori d
i int
erfa
ccia
DN
-12
Dat
i pro
cess
o le
ttur
a co
nfig
.
AO
-36
Cost
ante
di t
empo
filtr
o m
ors.
X42/
5PB
-63
Baud
rat
e at
tual
eEN
-11
Dur
ata
del c
olle
gam
ento
EN-9
9 Co
ntat
ori d
i med
iaD
N-1
3 Pa
ram
etro
di a
vvis
o
AO
-37
Corr
ente
zer
o m
ors.
X42
/5PB
-70
Mod
ifica
set
upEN
-12
Neg
ozia
zion
e au
tom
atic
aLN
-##
LON
WO
RKS
DN
-14
Rife
rimen
to re
te
AO
-4#
Usc
ita a
nalo
gica
X42
/7PB
-71
Salv
a va
lori
di d
ati P
rofib
usEN
-13
Velo
cità
di c
olle
gam
ento
LN-0
# ID
Lon
Wor
ksD
N-1
5 Co
ntro
llo r
ete
AO
-40
Usc
ita m
orse
tto
X42
/7PB
-72
Ripr
. con
v.fr
eq. P
rofib
usEN
-14
Link
dup
lex
LN-0
0 ID
Neu
ron
DN
-2#
Filtr
i CO
S
AO
-41
Mor
sett
o X
42/7
, sca
la m
in.
9-75
DO
Iden
tific
atio
nEN
-2#
Dat
i pro
cess
oLN
-1#
Funz
ioni
LO
ND
N-2
0 Fi
ltro
CO
S 1
AO
-42
Mor
s. X
42/7
, sca
la m
axPB
-80
Para
met
ri d
efin
iti (1
)EN
-20
Ista
nza
di c
ontr
ollo
LN-1
0 Pr
of. c
. fre
q.D
N-2
1 Fi
ltro
CO
S 2
AO
-43
Mor
s. X
42/7
, con
trol
lato
via
bus
PB-8
1 Pa
ram
etri
def
initi
(2)
EN-2
1 D
ati p
roce
sso
scr
ittur
a co
nfig
.LN
-15
Paro
la d
i avv
iso
LO
ND
N-2
2 Fi
ltro
CO
S 3
AO
-44
Prei
mp.
tim
eout
mor
s. X
42/7
PB-8
2 Pa
ram
etri
def
initi
(3)
EN-2
2 D
ati p
roce
sso
lett
ura
conf
ig.
LN-1
7 Re
visi
one
XIF
DN
-23
Filtr
o C
OS
4
AO
-5#
Usc
ita a
nalo
gica
X42
/9PB
-83
Para
met
ri d
efin
iti (4
)EN
-28
Mem
oriz
zare
i va
lori
di d
ati
LN-1
8 Re
visi
one
LonW
orks
DN
-3#
Acc
esso
ai p
aram
etri
AO
-50
Usc
ita m
orse
tto
X42
/9PB
-84
Para
met
ri d
efin
iti (5
)EN
-29
Mem
oriz
zare
sem
pre
LN-2
# A
cces
so p
aram
. LO
ND
N-3
0 In
d. a
rray
AO
-51
Mor
sett
o X
42/9
, sca
la m
in.
PB-9
0 Pa
ram
etri
cam
biat
i (1)
EN-3
# Et
herN
et/IP
LN-2
1 M
emor
izza
re i
valo
ri d
i
dati
DN
-31
Mem
oriz
zare
i va
lori
di d
ati
AO
-52
Mor
s. X
42/9
, sca
la m
assi
ma
PB-9
1 Pa
ram
etri
cam
biat
i (2)
EN-3
0 Pa
ram
etro
di a
vvis
oBN
-##
BACn
etD
N-3
2 Re
visi
one
Dev
icen
et
AO
-53
Mor
s. X
42/9
, con
trol
lato
via
bus
PB-9
2 Pa
ram
etri
cam
biat
i (3)
EN-3
1 Ri
ferim
ento
rete
BN-7
0 Is
tanz
a de
lla p
erife
rica
BACn
etD
N-3
3 M
emor
izza
re s
empr
e
AO
-54
Prei
mp.
tim
eout
mor
s. X
42/9
PB-9
3 Pa
ram
etri
cam
biat
i (4)
EN-3
2 Co
ntro
llo r
ete
BN-7
2 M
aste
r m
ax. M
S/TP
DN
-34
Codi
ce p
rodo
tto
Dev
iceN
et
Informazioni sulla programm... Guida rapida AF-600 FP
DET-759A/I 27
6 6
ID-#
# In
form
. con
v. fr
eq.
ID-4
2 Te
nsio
neD
R-12
Ten
sion
e m
otor
eD
R-6#
Ingr
essi
e u
scite
DR-
95 P
arol
a di
sta
to e
st. 2
ID-0
# D
ati d
i fun
zion
.ID
-43
Vers
ione
sof
twar
eD
R-13
Fre
quen
zaD
R-60
Ingr
. dig
itale
DR-
96 P
arol
a di
man
uten
zion
e
ID-0
0 O
re d
i fun
zion
amen
toID
-44
Num
ero
di m
odel
lo G
ED
R-14
Cor
rent
e m
otor
eD
R-61
Mor
s. 5
3 im
post
.co
mm
ut.
LG-#
# Lo
g e
sta
to o
pz. I
/O
ID-0
1 O
re e
serc
izio
ID-4
5 St
ringa
cod
ice
tipo
eff.
DR-
15 F
requ
enza
[%]
DR-
62 In
gr. a
nalo
g. 5
3LG
-0#
Log
man
uten
zion
e
ID-0
2 Co
ntat
ore
kWh
ID-4
6 N
. di p
rodo
tto
GE
DR-
16 C
oppi
a [N
m]
DR-
63 M
ors.
54
impo
st.
com
mut
.LG
-00
Log
man
uten
zion
e: E
lem
ento
ID-0
3 A
ccen
sion
iID
-47
N. d
i mod
ello
sch
eda
di p
oten
za G
ED
R-17
Vel
ocità
[giri
/m]
DR-
64 In
gr. a
nalo
g. 5
4LG
-01
Log
man
uten
zion
e: A
zion
e
ID-0
4 So
vrat
emp.
ID-4
8 N
. ID
tas
tierin
oD
R-18
Ter
m. m
otor
eD
R-65
Usc
ita a
nalo
gica
42
[mA
]LG
-02
Log
man
uten
zion
e: T
empo
ID-0
5 So
vrat
ensi
oni
ID-4
9 Sc
heda
di c
ontr
. SW
idD
R-22
Cop
pia
[%]
DR-
66 U
scita
dig
itale
[bin
]LG
-03
Log
man
uten
zion
e: D
ata
e or
a
ID-0
6 Ri
pris
t. co
ntat
. kW
hID
-50
Sche
da d
i pot
. SW
idD
R-3#
Sta
to c
onv.
freq
.D
R-67
Ingr
. fre
q. #
29 [H
z]LG
-1#
Log
mod
. inc
endi
o
ID-0
7 Ri
pris
tino
con
tato
re o
re d
i ese
rciz
ioID
-51
Num
ero
di s
erie
del
con
v. d
i fre
q.D
R-30
Ten
sion
e bu
s CC
DR-
68 In
gr. f
req.
33#
[Hz]
LG-1
0 Lo
g m
od. i
ncen
dio:
Eve
nto
ID-0
8 N
umer
o d
i avv
iam
enti
ID-5
3 N
. di s
erie
sch
eda
di p
oten
zaD
R-32
Ene
rgia
fren
o/s
DR-
69 U
scita
impu
lsi #
27 [H
z]LG
-11
Log
mod
. inc
endi
o: T
empo
ID-1
# Im
post
az. t
ende
nza
dati
ID-6
# Id
ent.
opz.
DR-
33 E
nerg
ia fr
eno/
2 m
inD
R-70
Usc
ita im
puls
i #29
[Hz]
LG-1
2 Lo
g m
od. i
ncen
dio:
Dat
a e
ora
ID-1
0 So
rgen
te t
ende
nza
ID-6
0 O
pzio
ne in
stal
lata
DR-
34 T
emp.
dis
sip.
DR-
71 U
scita
relè
[bin
]LG
-3#
Stat
o o
pzio
ne I/
O
ID-1
1 In
terv
allo
tend
enza
ID-6
1 Ve
rsio
ne S
W o
pzio
neD
R-35
Ter
mic
a in
vert
erD
R-72
Con
tato
re A
LG-3
0 In
gr. a
nal.
X42/
1
ID-1
2 Ev
ento
d'a
ttiv
azio
neID
-62
N. o
rdin
e op
zion
eD
R-36
Cor
r. no
m. c
. di f
req.
DR-
73 C
onta
tore
BLG
-31
Ingr
. ana
l. X4
2/3
ID-1
3 M
odo
ten
denz
aID
-63
N. d
i ser
ie o
pzio
neD
R-37
Cor
rent
e m
ax C
orre
nte
DR-
75 In
gr. a
nal.
X30/
12LG
-32
Ingr
. ana
l. X4
2/5
ID-1
4 Ca
mpi
onam
enti
prim
a de
ll'at
ti-va
zion
eID
-9#
Info
rm. p
aram
etri
DR-
38 S
tato
Log
ic C
ontr
olle
rD
R-76
Ingr
. ana
l. X3
0/12
LG-3
3 U
scita
ana
l. X4
2/7
[V]
ID-2
# Lo
g s
toric
oID
-92
Para
met
ri d
efin
itiD
R-39
Tem
p. s
ched
a di
con
trol
loD
R-77
Usc
ita a
nalo
gica
X30
/8[m
A]
LG-3
4 U
scita
ana
l. X4
2/9
[V]
ID-2
0 Lo
g s
toric
o: E
vent
oID
-93
Para
met
ri m
odifi
cati
DR-
40 B
uffe
r te
nden
za p
ieno
DR-
8# F
ield
bus
e po
rta
conv
. di
freq
.LG
-35
Usc
ita a
nal.
X42/
11 [V
]
ID-2
1 Lo
g s
toric
o: V
alor
eD
R-##
Vis
ualiz
z. d
ati
DR-
43 S
tato
azi
oni t
empo
rizza
teD
R-80
Par
. com
. 1 F
.bus
AP-
## P
ar. a
ppl.
HVA
C
ID-2
2 Lo
g s
toric
o: T
empo
DR-
0# S
tato
gen
eral
eD
R-49
Sor
gent
e co
rren
te d
i gua
sto
DR-
82 R
IF b
us d
i cam
po 1
AP-
0# V
arie
ID-2
3 Lo
g s
toric
o: D
ata
e or
aD
R-00
Par
ola
di c
ontr
ollo
DR-
5# R
if. e
retr
oaz.
DR-
84 O
pz. c
om. p
ar. s
tato
AP-
00 R
itard
o in
terb
locc
o e
ster
no
ID-3
# Lo
g a
llarm
eD
R-01
Rife
rimen
to [u
nità
]D
R-50
Rife
rimen
to e
ster
noD
R-85
Par
. com
. 1 p
. con
v.A
P-2#
Rile
vam
. por
tata
nul
la
ID-3
0 Lo
g a
llarm
e: C
odic
e gu
asto
DR-
02 R
iferim
ento
[%]
DR-
52 R
etro
azio
ne [u
nità
]D
R-86
RIF
1 p
orta
con
vert
itore
di fr
eque
nza
AP-
20 S
etup
aut
om. b
assa
pot
enza
ID-3
1 Lo
g a
llarm
e: V
alor
eD
R-03
Par
ola
di s
tato
DR-
53 R
iferim
. pot
. dig
it.D
R-9#
Vis
ualiz
z. d
iagn
.A
P-21
Rile
vam
. bas
sa p
oten
za
ID-3
2 Lo
g a
llarm
e: T
empo
DR-
05 V
al. r
eale
prin
c. [%
]D
R-54
Ret
roaz
ione
1 [u
nità
]D
R-90
Par
ola
d'al
larm
eA
P-22
Rile
vam
. bas
sa v
eloc
ità
ID-3
3 Lo
g a
llarm
e: D
ata
e or
aD
R-09
Vis
ual.
pers
onal
iz.
DR-
55 R
etro
azio
ne 2
[uni
tà]
DR-
91 P
arol
a d'
alla
rme
2A
P-23
Fun
zion
e as
senz
a di
por
tata
ID-4
# Id
entif
. con
v. fr
eq.
DR-
1# S
tato
mot
ore
DR-
56 R
etro
azio
ne 3
[uni
tà]
DR-
92 P
arol
a di
avv
iso
AP-
24 R
itard
o a
ssen
za d
i flu
sso
ID-4
0 Ti
po d
i c. d
i f.
DR-
10 P
oten
za [k
W]
DR-
58 U
scita
PID
[%]
DR-
93 P
arol
a di
avv
iso
2A
P-26
Fun
z. p
ompa
a s
ecco
ID-4
1 Se
zion
e po
tenz
aD
R-11
Pot
enza
[hp]
D
R-94
Par
ola
di s
tato
est
.A
P-27
Rita
rdo
funz
iona
men
to p
ompa
ase
cco
Informazioni sulla programm... Guida rapida AF-600 FP
28 DET-759A/I
66
AP-
3# T
arat
. pot
. a p
orta
ta n
ulla
AP-
72 T
. max
sca
tto
avv
iam
. com
pr.
FB-1
0 Fu
nzio
ne D
rive
Bypa
ssT-
5# L
og e
nerg
iaCL
-07
Conv
ersi
one
della
ret
roaz
ione
3
AP-
30 P
oten
za a
por
tata
nul
laA
P-73
Tem
po d
i acc
eler
azio
ne a
ll'av
vio
FB-1
1 Te
mpo
rita
rdo
byp
ass
conv
. di f
req.
T-50
Ris
oluz
ione
log
ene
rgia
CL-0
8 U
nità
font
e re
troa
zion
e 3
AP-
31 F
atto
re c
orre
zion
e po
tenz
aA
P-75
Pro
t. c
iclo
bre
veFB
-20
Funz
ione
Rot
ore
bloc
cato
T-51
Iniz
io p
erio
doCL
-12
Uni
tà ri
ferim
ento
/Ret
roaz
ione
AP-
32 B
assa
vel
ocità
[giri
/min
]A
P-76
Inte
rval
lo t
ra g
li av
viam
enti
FB-2
1 Ro
tore
blo
ccat
o, C
oeffi
cien
te1
T-53
Log
ene
rgia
CL-1
3 Ri
ferim
ento
min
imo/
retr
oaz.
AP-
33 B
assa
vel
ocità
[Hz]
AP-
77 T
empo
cic
lo m
inim
oFB
-22
Roto
re b
locc
ato,
Coe
ffici
ente
2T-
54 R
ipris
t. lo
g e
nerg
iaCL
-14
Rife
rimen
to m
ax./r
etro
az.
AP-
34 P
oten
za b
assa
vel
ocità
[kW
]A
P-8#
Com
pens
azio
ne d
el fl
usso
FB-2
3 Ro
tore
blo
ccat
o, C
oeffi
cien
te3
T-6#
Ten
denz
aCL
-20
Funz
ione
di r
etro
azio
ne
AP-
35 P
oten
za b
assa
vel
ocità
[HP]
AP-
80 C
omp.
del
flus
soFB
-24
Roto
re b
locc
ato,
coe
ffici
ente
4T-
60 V
aria
bile
ten
denz
aCL
-21
Rife
rimen
to 1
AP-
36 A
lta v
eloc
ità [g
iri/m
in.]
AP-
81 A
ppro
ss. l
inea
re-q
uadr
atic
aFB
-30
Funz
ione
mot
ore
man
cant
eT-
61 D
ati c
onte
nito
re c
ontin
uiCL
-22
Rife
rimen
to 2
AP-
37 A
lta v
eloc
ità [H
z]A
P-82
Cal
colo
del
pun
to d
i lav
oro
FB-3
1 M
otor
e m
anca
nte,
Coe
ffici
ente
1
T-62
Dat
i con
teni
tore
tem
poriz
zati
CL-2
3 Se
tpoi
nt 3
AP-
38 P
oten
za a
lta v
eloc
ità [k
W]
AP-
83 V
el. a
por
tata
nul
la [g
iri/m
]FB
-32
Mot
ore
man
cant
e, C
oeffi
cien
te2
T-63
Iniz
io p
erio
do te
mpo
r.CL
-3#
Retr
oazi
one
conv
. ava
nz.
AP-
39 P
oten
za a
lta v
eloc
ità [H
P]A
P-84
Vel
. a p
orta
ta n
ulla
[Hz]
FB-3
3 M
otor
e m
anca
nte,
Coe
ffici
ente
3T-
64 T
erm
ine
perio
do te
mpo
r.CL
-30
Refr
iger
ante
AP-
4# M
odo
pau
saA
P-85
Vel
ocità
nom
inal
e [g
iri/m
]FB
-34
Mot
ore
man
cant
e, C
oeffi
cien
te4
T-65
Val
ore
cont
enito
re m
inim
oCL
-31
Refr
iger
ante
A1
defin
itoda
ll'ut
ente
AP-
40 T
empo
cic
lo m
inim
oA
P-86
Vel
ocità
nom
inal
e [H
z]T-
## F
unzi
oni t
empo
rizza
teT-
66 R
ipris
t. d
ati c
onte
nito
reco
ntin
uiCL
-32
Refr
iger
ante
A2
defin
itoda
ll'ut
ente
AP-
41 T
empo
di p
ausa
min
imo
AP-
87 P
ress
ione
alla
vel
. a p
orta
ta n
ulla
T-0#
Fun
zion
i tem
poriz
zate
T-67
Rip
rist.
dat
i con
teni
tore
tem
por.
CL-3
3 Re
frig
eran
te A
3 de
finito
dall'
uten
te
AP-
42 V
eloc
ità fi
ne p
ausa
[giri
/m]
AP-
88 P
ress
ione
alla
vel
ocità
nom
.T-
00 T
empo
ON
T-8#
Con
tato
re a
mm
orta
men
toCL
-34
Are
a co
ndot
to 1
[m2]
AP-
43 V
eloc
ità fi
ne p
ausa
[Hz]
AP-
89 P
orta
ta n
omin
ale
T-01
Azi
one
ON
T-80
Fat
tore
rife
rimen
to d
ipo
tenz
aCL
-35
Are
a co
ndot
to 1
[in2
]
AP-
44 D
iff. r
if./r
etro
az. f
ine
paus
aA
P-90
Por
tata
alla
vel
ocità
nom
.T-
02 T
empo
di O
FFT-
81 C
osto
ene
rgia
CL-3
6 A
rea
cond
otto
2 [m
2]
AP-
45 R
iferim
ento
pre
-pau
saFB
-##
Ope
razi
one
ince
ndio
/ b
ypas
sT-
03 A
zion
e O
FFT-
82 In
vest
imen
toCL
-37
Are
a co
ndot
to 2
[in2
]
AP-
46 T
empo
mas
sim
o p
re p
ausa
FB-0
# M
odal
ità in
cend
ioT-
04 R
icor
renz
aT-
83 R
ispa
rmi e
nerg
etic
iCL
-38
Fatt
ore
di d
ensi
tà d
ell'a
ria [%
]
AP-
5# F
ine
curv
aFB
-00
Funz
ione
Fire
Mod
eT-
08 M
odal
ità a
zion
i tem
poriz
zate
T-84
Ris
parm
io d
i cos
tiCL
-7#
Aut
otar
atur
a PI
D
AP-
50 F
unzi
one
fine
curv
aFB
-01
Conf
igur
azio
ne m
od. i
ncen
dio
T-09
Ria
ttiv
azio
ne a
zion
i tem
poriz
zate
CL-#
# PI
D a
nello
chi
uso
CL-7
0 Ti
po a
d a
nello
chi
uso
AP-
51 R
itard
o fi
ne c
urva
FB-0
2 U
nità
Fire
Mod
eT-
1# M
anut
enzi
one
CL-0
# Re
troa
zion
eCL
-71
Pres
tazi
oni P
ID
AP-
6# R
ileva
m. c
ingh
ia ro
tta
FB-0
3 Ri
ferim
ento
min
. mod
. inc
endi
oT-
10 E
lem
ento
sog
gett
o a
man
uten
zion
eCL
-00
Font
e re
troa
zion
e 1
CL-7
2 M
odifi
ca u
scita
PID
AP-
60 F
unzi
one
cing
hia
rott
aFB
-04
Rife
rimen
to m
ax. F
ire M
ode
T-11
Inte
rven
to d
i man
uten
zion
eCL
-01
Conv
ersi
one
retr
oazi
one
1CL
-73
Live
llo d
i ret
roaz
ione
min
.
AP-
61 C
oppi
a ci
nghi
a ro
tta
FB-0
5 Ri
ferim
. pre
imp.
mod
. inc
endi
oT-
12 B
ase
tem
po m
anut
enzi
one
CL-0
2 U
nità
font
e re
troa
zion
e 1
CL-7
4 Li
vello
di r
etro
azio
ne m
ax.
AP-
62 R
itard
o c
ingh
ia r
otta
FB-0
6 O
rigin
e rif
erim
. mod
. inc
endi
oT-
13 In
terv
allo
tem
po m
anut
enzi
one
CL-0
3 Fo
nte
retr
oazi
one
2CL
-79
Aut
otar
atur
a PI
D
AP-
7# C
ompr
esso
reFB
-07
Orig
ine
retr
oazi
one
mod
alità
ince
ndio
T-14
Dat
a e
ora
man
uten
zion
eCL
-04
Conv
ersi
one
retr
oazi
one
2CL
-8#
Impo
st. d
i bas
e PI
D
AP-
70 V
el. m
ax. d
i avv
iam
. com
p. [g
iri/
min
]FB
-09
Ges
tione
alla
rmi f
ire m
ode
T-15
Rip
rist.
par
ola
man
uten
zion
eCL
-05
Uni
tà fo
nte
retr
oazi
one
2CL
-81
PID
, con
tr. n
./inv
.
AP-
71 V
el. m
ax. d
i avv
iam
. com
p. [H
z]FB
-1#
Bypa
ss d
el c
onve
rtito
re d
i fre
quen
zaT-
16 T
esto
di m
anut
enzi
one
CL-0
6 Fo
nte
retr
oazi
one
3CL
-82
Velo
cità
di a
vvia
m. P
ID [g
iri/m
in]
Informazioni sulla programm... Guida rapida AF-600 FP
DET-759A/I 29
6 6
CL-8
3 Ve
loci
tà a
vvia
men
to P
ID [H
z]XC
-23
Tem
po d
i der
ivaz
ione
est
. 1XC
-61
Gua
dagn
o p
ropo
rzio
nale
est.
3PC
-43
Sogl
ia d
i dis
attiv
azio
neLC
-01
Even
to a
vvia
men
to
CL-8
4 A
mpi
ezza
di b
anda
rifer
imen
to a
XC-2
4 Li
mite
gua
d. d
eriv
. est
. 1XC
-62
Tem
po d
'inte
graz
. est
. 3PC
-44
Velo
cità
di a
ttiv
az. [
giri/
m]
LC-0
2 Ev
ento
arr
esto
CL-9
# Co
ntro
llore
PID
XC-3
# Ri
f./re
troa
z. C
L 2
est.
XC-6
3 Te
mpo
diff
eren
zial
e es
t. 3
PC-4
5 Ve
loci
tà d
i att
ivaz
ione
[Hz]
LC-0
3 Ri
pr. i
l con
tr. l
ogic
o
CL-9
1 A
nti s
atur
azio
ne P
IDXC
-30
Uni
tà r
if./r
etro
azio
ne e
st. 2
XC-6
4 Li
mite
gua
d. d
eriv
. est
. 3PC
-46
Velo
cità
di d
isat
tivaz
ione
[giri
/m]
LC-1
# Co
mpa
rato
ri
CL-9
3 G
uada
gno
pro
porz
iona
le P
IDXC
-31
Rife
rimen
to m
inim
o e
st. 2
PC-#
# Co
ntro
llore
pom
paPC
-47
Velo
cità
di d
isat
tivaz
ione
[Hz]
LC-1
0 O
pera
ndo
com
para
tore
CL-9
4 Te
mpo
di i
nteg
razi
one
PID
XC-3
2 Ri
ferim
ento
max
. est
. 2PC
-0#
Impo
staz
ioni
di s
iste
ma
PC-5
# Im
post
. alte
rnan
zaLC
-11
Ope
rato
re c
ompa
rato
re
CL-9
5 Te
mpo
di d
eriv
azio
ne P
IDXC
-33
Font
e rif
erim
ento
est
. 2PC
-00
Cont
rollo
re p
ompe
PC-5
0 A
ltern
anza
pom
pa p
rimar
iaLC
-12
Valo
re c
ompa
rato
re
CL-9
6 PI
D, l
imite
gua
d. d
eriv
.XC
-34
Font
e re
troa
zion
e es
t. 2
PC-0
2 A
vvia
men
to m
otor
ePC
-51
Even
to d
i alte
rnan
zaLC
-2#
Tim
er
XC-#
# A
nello
chi
uso
PID
est
.XC
-35
Rife
rimen
to e
st. 2
PC-0
4 Fu
nzio
ne c
iclo
pom
pePC
-52
Int.
tem
po d
i alte
rn.
LC-2
0 Ti
mer
con
trol
lore
logi
co
XC-0
# Ta
rat.
aut
om. C
L es
t.XC
-37
Rife
rimen
to e
st. 2
[uni
tà]
PC-0
5 Po
mpa
prim
aria
fiss
aPC
-53
Valo
re te
mpo
alte
rnan
zaLC
-4#
Rego
le lo
gich
e
XC-0
0 Ti
po a
d a
nello
chi
uso
XC-3
8 Re
troa
zion
e es
t. 2
[uni
tà]
PC-0
6 N
umer
o d
i pom
pePC
-54
Tem
po d
i alte
rnan
za p
rede
f.LC
-40
Rego
la lo
gica
Boo
lean
a 1
XC-0
1 Pr
esta
zion
i PID
XC-3
9 U
scita
est
. 2 [%
]PC
-10
Ove
rrid
e te
mpo
cic
lom
inim
oPC
-55
Alte
rnar
e se
il c
aric
o <
50%
LC-4
1 O
pera
tore
rego
la lo
gica
1
XC-0
2 M
odifi
ca u
scita
PID
XC-4
# PI
D C
L 2
est.
PC-1
1 Va
lore
di o
verr
ide
tem
poci
clo
min
imo
PC-5
6 M
odo
di a
ttiv
. alte
rnan
zaLC
-42
Rego
la lo
gica
Boo
lean
a 2
XC-0
3 Li
vello
di r
etro
azio
ne m
in.
XC-4
0 Co
ntro
llo N
orm
ale/
Inve
rso
est
. 2PC
-2#
Impo
st. l
argh
. di b
anda
PC-5
8 Ri
tard
o fu
nz. p
ompa
suc
c.LC
-43
Ope
rato
re re
gola
logi
ca 2
XC-0
4 Li
vello
di r
etro
azio
ne m
ax.
XC-4
1 G
uada
gno
pro
porz
iona
le e
st. 2
PC-2
0 La
rgh.
di b
anda
att
ivaz
.PC
-59
Rita
rdo
funz
. in
line
aLC
-44
Rego
la lo
gica
Boo
lean
a 3
XC-0
9 A
utot
arat
ura
PID
XC-4
2 Te
mpo
d'in
tegr
az. e
st. 2
PC-2
1 La
rgh.
di b
anda
esc
lus.
PC-8
# St
ato
LC-5
# St
ati
XC-1
# Ri
f./re
troa
z. C
L 1
est.
XC-4
3 Te
mpo
di d
eriv
azio
ne e
st. 2
PC-2
2 La
rgh.
di b
anda
vel
. fis
saPC
-80
Stat
o p
ompa
LC-5
1 Ev
ento
con
trol
lore
logi
co
XC-1
0 U
nità
rif./
retr
oazi
one
est.
1XC
-44
Lim
ite g
uad.
gua
d. d
eriv
.PC
-23
SBW
rita
rdo
all'
attiv
azio
nePC
-81
Stat
o p
ompa
LC-5
2 A
zion
e de
l con
trol
lore
logi
co
XC-1
1 Ri
ferim
ento
min
imo
est
. 1XC
-5#
Rif./
retr
oaz.
CL
3 es
t.PC
-24
Rita
rdo
alla
dis
attiv
azio
neSB
WPC
-82
Pom
pa p
rimar
iaB-
## F
unzi
oni f
reno
XC-1
2 Ri
ferim
ento
max
. est
. 1XC
-50
Uni
tà r
if./r
etro
azio
ne e
st. 3
PC-2
5 Te
mpo
OBW
PC-8
3 St
ato
dei
relè
B-0#
Fre
no C
C
XC-1
3 Fo
nte
rifer
imen
to e
st. 1
XC-5
1 Ri
ferim
ento
min
imo
est
. 3
PC-2
6 D
isat
tivaz
ione
a p
orta
ta
nulla
PC-8
4 Te
mpo
pom
pa O
NB-
00 C
orre
nte
CC d
i man
teni
men
to
XC-1
4 Fo
nte
retr
oazi
one
est.
1XC
-52
Rife
rimen
to m
ax. e
st. 3
PC-2
7 Fu
nzio
ne a
ttiv
azio
nePC
-85
Tem
po re
lè O
NB-
01 C
orre
nte
di fr
enat
ura
CC
XC-1
5 Ri
ferim
ento
est
. 1XC
-53
Font
e rif
erim
ento
est
. 3PC
-28
Tem
po fu
nzio
ne a
ttiv
azio
nePC
-86
Ripr
istin
o c
onta
tori
relè
B-02
Tem
po d
i fre
nata
CC
XC-1
7 Ri
ferim
ento
est
. 1 [u
nità
]XC
-54
Font
e re
troa
zion
e es
t. 3
PC-2
9 Fu
nzio
ne d
isat
tivaz
ione
PC-9
# M
anut
enzi
one
B-03
Vel
. ins
erim
. fre
natu
ra C
C [R
PM]
XC-1
8 Re
troa
zion
e es
t. 1
[uni
tà]
XC-5
5 Ri
ferim
ento
est
. 3
PC-3
0 Te
mpo
funz
ione
dis
atti-
vazi
one
PC-9
0 In
terb
locc
o p
ompa
B-04
Vel
ocità
inse
rimen
to fr
enat
ura
CC
[Hz]
XC-1
9 U
scita
est
. 1 [%
]XC
-57
Rife
rimen
to e
st. 3
[uni
tà]
PC-4
# Im
post
azio
ni a
ttiv
az.
PC-9
1 A
ltern
anza
man
uale
B-1#
Fun
z. e
nerg
ia fr
eno
XC-2
# PI
D C
L 1
est.
XC-5
8 Re
troa
zion
e es
t. 3
[uni
tà]
PC-4
0 Ri
tard
o ra
mpa
di d
ecel
e-ra
zion
eLC
-##
Cont
rollo
re lo
gico
B-10
Fun
zion
e fr
eno
XC-2
0 Co
ntro
llo N
orm
ale/
Inve
rso
est.
1XC
-59
Usc
ita e
st. 3
[%]
PC-4
1 Ri
tard
o ra
mpa
di a
ccel
.LC
-0#
Impo
staz
ioni
LC
B-16
Cor
rent
e m
ax. f
reno
CA
XC-2
1 G
uada
gno
pro
porz
iona
le e
st.
1XC
-6#
PID
CL
3 es
t.PC
-42
Sogl
ia d
i att
ivaz
ione
LC-0
0 M
odo
con
trol
lore
logi
coB-
17 C
ontr
ollo
sov
rate
nsio
ne O
VC
XC-2
2 Te
mpo
d'in
tegr
az. e
st. 1
XC-6
0 Co
ntro
llo N
orm
ale/
Inve
rso
est
. 3
Informazioni sulla programm... Guida rapida AF-600 FP
30 DET-759A/I
66
6.2 Programmazione remota con DCT-10
GE offre un programma software per lo sviluppo, lamemorizzazione e il trasferimento della convertitore difrequenza programmazione. Il DCT-10 consente all'utentedi collegare un PC al convertitore di frequenza ed eseguirela programmazione in tempo reale invece di utilizzarel'tastiera. Inoltre tutta la programmazione del convertitoredi frequenza è eseguibile off-line e scaricabile sempli-cemente nel convertitore di frequenza. Oppure è possibilecaricare l'intero profilo del convertitore di frequenza su PCper il backup o l'analisi.
Per la connessione al convertitore di frequenza sonodisponibili il connettore USB o il morsetto RS-485.
Per maggiori dettagli, andare a www.geelectrical.com/drives
Informazioni sulla programm... Guida rapida AF-600 FP
DET-759A/I 31
6 6
7 Avvisi e allarmi
7.1 Avvisi e allarmi
Tabella 7.1 definisce se un avviso viene emesso prima di un allarme e se l'allarme fa scattare l'unità o blocca l'unità.
N° Descrizione Avviso Allarme/scatto All./scatto blocc. Riferimento parametro1 10V basso X
2 Guasto z. trasl. (X) (X) AN-01 Funz. temporizz.tensione zero
4 Perdita fase di rete (X) (X) (X) SP-12 Funz. durantesbilanciamento di linea
5 Tensione collegamento CC alta X
6 Tensione bus CC bassa X
7 Sovratens. CC X X
8 Sottotens. CC X X
9 Inverter sovracc. X X
10 Sovratemperatura Sovraccarico termicoelettronicodel motore
(X) (X) F-10 Sovraccaricoelettronico
11 Sovratemp. term. motore (X) (X) F-10 Sovraccaricoelettronico
12 Limite di coppia X X
13 Sovracorrente X X X
14 Guasto di terra X X X
15 Errore hardware X X
16 Cortocircuito X X
17 TO par. contr. (X) (X) O-04 Funzione temporizz.
parola di controllo
18 Avviamento non riuscito
23 Guasto interno ventola X
24 Guasto esterno ventola X SP-53 Monitor. ventola
29 Sovratemperatura conv. freq. X X X
30 Fase U del motore mancante (X) (X) (X) H-78 Funzione fase motoremancante
31 Fase V del motore mancante (X) (X) (X) H-78 Funzione fase motore
mancante
32 Fase W del motore mancante (X) (X) (X) H-78 Funzione fase motoremancante
33 Gu. accens. X X
34 Errore comunicazione bus di campo X X
35 Guasto opzione X X
36 Guasto di rete X X
38 Guasto interno X X
39 Sens. dissip. X X
40 Sovraccarico dell'uscita dig. mors. 27 (X) E-00 Modo I/O digitale,E-51 Modo Morsetto 27
41 Sovraccarico dell'uscita dig. mors. 29 (X) E-00 Modo I/O digitale,E-52 Modo morsetto 29
42 Sovraccarico dell'uscita dig. X30/6 (X) E-56 Uscita dig. mors.X30/6 (OPCGPIO)
42 Sovraccarico dell'uscita dig. X30/7 (X) E-57 Uscita dig. mors.
X30/7 (OPCGPIO)
Avvisi e allarmi Guida rapida AF-600 FP
32 DET-759A/I
77
N° Descrizione Avviso Allarme/scatto All./scatto blocc. Riferimento parametro45 45 Guasto di terra 2
46 Alim. sch. pot X X
47 Alim. 24 V b. X X X
48 Al. 1,8V bassa X X
49 Lim. velocità X (X) H-36 Velocità media bassa[giri/min]
50 Taratura Auto Tune (taratura automatica)fallita
X
51 Auto Tune (taratura automatica) controllo
Unom e Inom
X
52 Auto Tune (taratura automatica) Inom bassa X
53 Auto Tune (taratura automatica) motoretroppo grande
X
54 Auto Tune (taratura automatica) motoretroppo piccolo
X
55 Auto Tune (taratura automatica) parametrofuori intervallo
X
56 Auto Tune (taratura automatica) interrottodall'utente
X
57 Time-out Auto Tune (taratura automatica) X
58 Guasto interno Auto Tune (taratura
automatica)
X X
59 Limite corrente X
60 Interbl. esterno X
62 Limite massimo frequenza di uscita X
64 Limite tens. X
65 Sovratemperatura scheda di comando X X X
66 Temp. dissip. X
67 Configurazione opzioni cambiata X
69 Temp. scheda pot. X X
70 Configurazione non consentita Convertitore difrequenza
X
76 Setup unità pot. X
79 Conf. PS n. cons. X X
80 Inverter inizial. al valore di default X
91 Errato setup ingresso analogico 54 X
92 Portata nulla X X AP-2#
93 P. a secco X X AP-2#
94 Fine curva X X AP-5#
95 Cinghia rotta X X AP-6#
96 Avviam. rit. X AP-7#
97 Arr. ritard. X AP-7#
98 Errore orologio X K-7#
201 Fire M era att.
202 Limiti Fire M superati
203 Mot. manc.
204 Rotore bloccato
243 IGBT freno X X
244 Temp. dissip. X X X
245 Sens. dissip. X X
246 Alim. sch. pot X X
247 Temp. sch. pot X X
248 Conf. PS n. cons. X X
Avvisi e allarmi Guida rapida AF-600 FP
DET-759A/I 33
7 7
N° Descrizione Avviso Allarme/scatto All./scatto blocc. Riferimento parametro250 Nuove parti di ric. X
251 Nuovo cod. tipo X X
Tabella 7.1 Lista di codici di allarme/avviso
(X) Dipende dal parametro1) Non è possibile autoripristinare tramite H-04 Ripristino automatico (tempi)
NOTA!Fare riferimento al Manuale di Funzionamento AF-600 FP per una descrizione dettagliata e la ricerca ed eliminazione deiguasti.
Avvisi e allarmi Guida rapida AF-600 FP
34 DET-759A/I
77
8 Specifiche
8.1 Dati tecnici generali
Alimentazione di rete (L1, L2, L3):Tensione di alimentazione 200-240V ±10%, 380-480V ±10%, 525-600V ±10%, 525-690V ±10%
Tensione di alimentazione insufficiente / caduta tensione di rete:Durante una caduta di tensione di rete o con tensione di alimentazione insufficiente, il convertitore di frequenza continua afunzionare fino a quando la tensione sul circuito intermedio non scende al di sotto del livello minimo di arresto, il che di normacorrisponde al 15% in meno della tensione di alimentazione nominale minima. Accensione e funzionamento alla coppiamassima non sono possibili se la tensione di alimentazione è oltre il 10% al di sotto della tensione di alimentazione nominaleminima del convertitore di frequenza.
Frequenza di alimentazione 50/60Hz ±5%Sbilanciamento massimo temporaneo tra le fasi di alimentazione 3,0% della tensione di alimentazione nominaleFattore di potenza reale () ≥ 0,9 nominale al carico nominaleFattore di dislocazione di potenza (cos) prossimo all'unità (> 0,98)Commutazione sull'alimentazione di ingresso L1, L2, L3 (accensioni) ≤ 7,5kW / 10HP e inferiore al massimo 2 volte/min.Commutazione sull'alimentazione di ingresso L1, L2, L3 (accensioni) ≥ 7,5kW / 10HP e inferiore al massimo 1 volta/min.Commutazione sull'alimentazione di ingresso L1, L2, L3 (accensioni) ≥ 110kW/150HP e superiore al massimo 1 volta/2 min.Ambiente secondo la norma EN60664-1 categoria di sovratensione III / grado di inquinamento 2
L'unità è adatta per un uso su un circuito in grado di fornire non oltre 100.000 amp. RMS simmetrici, max. 240/480/600 V.
Uscita motore (U, V, W):Tensione di uscita 0 - 100% della tensione di alimentazioneFrequenza di uscita (0,25-75kW)/(75kW / 125HP) 0 - 1000HzFrequenza di uscita (90-1000kW)/(90kW / 150HP) 0 - 8001)HzFrequenza di uscita in modalità Flux 0 - 300HzCommutazione sull'uscita IllimitataTempi di rampa 0,01 - 3600sec.
1) In funzione della tensione e della corrente di alimentazione
Caratteristiche di coppia:Coppia di avviamento (coppia costante) al massimo 160% per 60 sec.1)
Coppia di avviamento al massimo 180 % fino a 0,5 sec.1)
Coppia di sovraccarico (coppia costante) al massimo 160% per 60 sec.1)
Coppia di avviamento (Coppia variabile) al massimo 110% per 60 sec.1)
Coppia di sovraccarico (coppia variabile) al massimo 110% per 60 s
Tempo di incremento di coppia in (independente da fsw) 10msTempo di incremento di coppia nel controllo vettoriale di flusso (per 5 kHz fsw) 1ms
1) La percentuale si riferisce alla coppia nominale.2) Il tempo di risposta della coppia dipende dall'applicazione e dal carico, ma come regola generale, il gradino di coppia da 0 alriferimento è 4-5 x il tempo di incremento di coppia.
Lunghezze e sezioni dei cavi:Lunghezza max. del cavo motore, schermato/armato 150 mLunghezza max. cavo motore, cavo non schermato/non armato 300 mSezione massima per i morsetti di controllo, cavo rigido 1,5 mm2/16 AWG (2 x 0,75 mm2)Sezione massima per i morsetti di controllo, cavo flessibile 1 mm2/18 AWGSezione massima per i morsetti di controllo, cavo con anima 0,5 mm2/20 AWGSezione minima per i morsetti di controllo 0,25 mm2
Specifiche Guida rapida AF-600 FP
DET-759A/I 35
8 8
Ingressi digitali:Ingressi digitali programmabili 4 (6)1)
Numero morsetto 18, 19, 271), 291), 32, 33,Logica PNP o NPNLivello di tensione 0 - 24V CCLivello di tensione, '0' logico PNP < 5V CCLivello di tensione, '1' logico PNP > 10V CCLivello di tensione, '0' logico NPN2) > 19V CCLivello di tensione, '1' NPN2) < 14V CCTensione massima sull’ingresso 28V CCIntervallo di frequenza impulsi 0 - 110kHz(Duty cycle) Ampiezza impulso min. 4,5msResistenza d'ingresso, Ri circa 4 kΩIngressi analogici:Numero di ingressi analogici 2Numero morsetto 53, 54Modalità Tensione o correnteSelezione modo Interruttore S201 e interruttore S202Modo tensione Interruttore S201/interruttore S202 = OFF (U)Livello di tensione Da -10 a +10 V (scalabile)Resistenza d'ingresso, Ri ca. 10 kΩTensione max. ± 20VModo corrente Interruttore S201/interruttore S202 = ON (I)Livello di corrente Da 0/4 a 20 mA (scalabile)Resistenza d'ingresso, Ri ca. 200 ΩCorrente max. 30 mARisoluzione per gli ingressi analogici 10 bit (+ segno)Precisione degli ingressi analogici Errore max. 0,5% del fondo scalaLarghezza di banda 100 Hz
Gli ingressi analogici sono isolati galvanicamente dalla tensione di alimentazione (PELV) e dagli altri morsetti ad alta tensione.
Ingressi a impulsi/encoder:Ingressi a impulsi/encoder programmabili 2/1Numero morsetto a impulsi/encoder 29, 331) / 322), 332)
Frequenza max. ai morsetti 29, 32, 33 110kHz (comando push-pull)Frequenza max. ai morsetti 29, 32, 33 5 kHz (collettore aperto)Frequenza min. ai morsetti 29, 32, 33 4 HzLivello di tensione vedere Tensione massima sull’ingresso 28V CCResistenza d'ingresso, Ri ca. 4kΩPrecisione dell'ingresso impulsi (0,1 - 1 kHz) Errore max.: 0,1% del fondo scalaPrecisione dell'ingresso encoder (1 - 11 kHz) Errore max.: 0,05% dell'intera scala
Gli ingressi a impulsi e encoder (morsetti 29, 32, 33) sono isolati galvanicamente dalla tensione di alimentazione (PEL V) nonchéda altri morsetti ad alta tensione.1) Gli ingressi a impulsi sono 29 e 332) Ingressi encoder: 32 = A e 33 = B
Specifiche Guida rapida AF-600 FP
36 DET-759A/I
88
Uscita analogica:Numero delle uscite analogiche programmabili 1Numero morsetto 42Intervallo di corrente sull'uscita analogica 0/4 - 20 mACarico max a massa - uscita analogica 500ΩPrecisione sull'uscita analogica Errore max.: 0,5% del fondo scalaRisoluzione sull'uscita analogica 12 bit
L’uscita analogica è isolata galvanicamente dalla tensione di alimentazione (PELV) e dagli altri morsetti ad alta tensione.
Scheda di controllo, comunicazione seriale RS-485:Numero morsetto 68 (P,TX+, RX+), 69 (N,TX-, RX-)Numero morsetto 61 Comune per i morsetti 68 e 69.
Il circuito di comunicazione seriale RS-485 è separato funzionalmente da altri circuiti centrali e isolato galvanicamente dallatensione di alimentazione (PELV).
Uscita digitale:Uscite programmabili digitali/a impulsi 2Numero morsetto 27, 29 1)
Livello di tensione sull'uscita digitale/frequenza 0 - 24VCorrente in uscita max. (sink o source) 40 mACarico max. sull’uscita in frequenza 1kΩCarico capacitivo max. sull’uscita in frequenza 10 nFFrequenza di uscita minima per l'uscita in frequenza 0HzFrequenza di uscita massima per l'uscita in frequenza 32 kHzPrecisione dell'uscita di frequenza Errore max.: 0,1 % del fondo scalaRisoluzione delle uscite di frequenza 12 bit
1) I morsetti 27 e 29 possono essere programmati come ingressi digitali.
L’uscita digitale è isolata galvanicamente dalla tensione di alimentazione (PELV) e dagli altri morsetti ad alta tensione.
Scheda di controllo, uscita 24V CC:Numero morsetto 12, 13Tensione di uscita 24V +1, -3 VCarico max. 200mA
L'alimentazione 24 V CC è isolata galvanicamente dalla tensione di alimentazione (PELV) ma ha lo stesso potenziale degliingressi e delle uscite analogici e digitali.
Uscite a relè:Uscite a relè programmabili 2 Form CNumero morsetto relè 01 1-3 (apertura), 1-2 (chiusura)Carico max. morsetti (CA-1)1) su 1-3 (NC), 1-2 (NO) (carico resistivo) 240 V CA, 2 ACarico max. morsetti (CA-15)1) (carico induttivo @ cosφ 0,4) 240 V CA, 0,2ACarico max. morsetti (CC-1)1) su 1-2 (NA), 1-3 (NC) (carico resistivo) 60V CC, 1ACarico max. morsetti (CC-13)1) (carico induttivo) 24V CC, 0,1ANumero morsetto relè 02 4-6 (apertura), 4-5 (chiusura)Carico max. morsetti (CA-1)1) su 4-5 (NO) (carico resistivo)2)3) Cat. sovratensione II 400V CA, 2ACarico max. morsetti (CA-15)1) su 4-5 (NO) (carico induttivo @ cosφ 0,4) 240 V CA, 0,2ACarico max. morsetti (CC-1)1) su 4-5 (NA) (carico resistivo) 80V CC, 2ACarico max. morsetti (CC-13)1) su 4-5 (NA) (carico induttivo) 24V CC, 0,1ACarico max. morsetti (CA-1)1) su 4-6 (NC) (carico resistivo) 240 V CA, 2 ACarico max. morsetti (CA-15)1) su 4-6 (NC) (carico induttivo con cosφ 0,4) 240 V CA, 0,2ACarico max. morsetti (CC-1)1) su 4-6 (NC) (carico resistivo) 50V CC, 2ACarico max. morsetti (CC-13)1) su 4-6 (NC) (carico induttivo) 24V CC, 0,1ACarico min. morsetti su 1-3 (NC), 1-2 (NA), 4-6 (NC), 4-5 (NA) 24V CC 10mA, 24V CA 20mAAmbiente secondo EN 60664-1 categoria di sovratensione III /grado di inquinamento 2
1) IEC 60947 parte 4 e 5I contatti del relè sono isolati galvanicamente dal resto del circuito mediante un isolamento rinforzato (PELV).2) Categoria di sovratensione II
Specifiche Guida rapida AF-600 FP
DET-759A/I 37
8 8
3) Applicazioni UL 300V CA 2A
Scheda di controllo, uscita 10 V CC:Numero morsetto 50Tensione di uscita 10,5V ±0,5VCarico max. 15mA
L’alimentazione 10V CC è isolata galvanicamente dalla tensione di alimentazione (PELV) nonché da altri morsetti ad altatensione.
Caratteristiche di comando:Risoluzione sulla frequenza d’uscita a 0 - 1000 Hz ± 0,003HzAccuratezza di ripetizione di Avviamento/arresto preciso (morsetti 18, 19) ≤± 0,1msTempo di risposta del sistema (morsetti 18, 19, 27, 29, 32, 33) ≤ 2msIntervallo controllo in velocità (anello aperto) 1:100 della velocità sincronaIntervallo controllo in velocità (anello chiuso) 1:1000 della velocità sincronaAccuratezza della velocità (anello aperto) 30 - 4000 giri/m: errore ±8 giri/min.Accuratezza della velocità (anello chiuso), in base alla risoluzione del dispositivo diretroazione 0 - 6000 giri/m: errore ±0,15 giri/min.Precisione di comando della coppia (retroazione della velocità) errore max±5% della coppia nominale
Tutte le caratteristiche di comando si basano su un motore asincrono quadripolare
Ambiente:Prova di vibrazione tutti i tipi di custodia 1,0gUmidità relativa 5% - 95% (IEC 721-3-3; classe 3K3 (senza condensa) durante il funzionamentoAmbiente aggressivo (IEC 60068-2-43) Test H2S classe KdMetodo di prova secondo la norma CEI 60068-2-43 H2S (10 giorni)Temperatura ambiente (modalità di commutazione a 60 AVM)- con declassamento max. 50°C1)
- con la massima potenza di uscita dei motori EFF2 tipici (fino al 90% della corrente di uscita) max. 50 °C1)
- a corrente di uscita continua massima del convertitore di frequenza max. 45 °C1)
1) Per maggiori informazioni sul declassamento, vedere la sezione relativa alle Condizioni speciali nella Guida alla ProgettazioneAF-600 FP.
Temperatura ambiente minima durante operazioni a pieno regime 0°CTemperatura ambiente minima con prestazioni ridotte - 10°CTemperatura durante il magazzinaggio/trasporto -25 - +65/70°°CAltezza massima sopra il livello del mare senza declassamento 1000mAltezza massima sopra il livello del mare con declassamento 3000m
Per il declassamento in caso di altitudine elevata, consultare la sezione relativa alle condizioni speciali
Standard EMC, emissione EN 61800-3, EN 61000-6-3/4, EN 55011, IEC 61800-3
Standard EMC, immunitàEN 61800-3, EN 61000-6-1/2,
EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6Prestazione scheda di controllo:Intervallo di scansione 1msScheda di controllo, comunicazione seriale USB:USB standard 1.1 (Full speed)Spina USB Spina USB tipo B
Il collegamento al PC viene effettuato mediante un cavo USB standard host/device.Il collegamento USB è isolato galvanicamente dalla tensione di rete (PELV) nonché dagli altri morsetti ad alta tensione.Il collegamento di massa USB non è isolato galvanicamente dalla terra di protezione. Usare solo un computer portatile isolaticome collegamento PC al connettore USB sul convertitore di frequenza.
Protezione e caratteristiche:
Specifiche Guida rapida AF-600 FP
38 DET-759A/I
88
• Protezione termica elettronica del motore contro il sovraccarico.
• Il monitoraggio termico del dissipatore garantisce lo scatto del convertitore di frequenza nel caso in cui latemperatura raggiunga un livello predefinito. La sovratemperatura non può essere ripristinata finché latemperatura del dissipatore non scende sotto i valori indicati nelle tabelle sulle pagine seguenti (linee guida -queste temperature possono variare per taglia di potenza, dimensioni unità, gradi di protezione ecc.).
• Il convertitore di frequenza è protetto dai cortocircuiti sui morsetti del motore U, V, W.
• In mancanza di una fase di rete, il convertitore di frequenza scatta o emette un avviso (a seconda del carico).
• Il monitoraggio della tensione del circuito intermedio garantisce l’esclusione del convertitore di frequenza nel casoin cui la tensione del circuito intermedio sia troppo bassa o troppo alta.
• Il convertitore di frequenza sorveglia continuamente i livelli critici di temperatura interna, la corrente di carico,l'alta tensione sul circuito intermedio e le basse velocità motore. Come risposta a un livello critico, il convertitore difrequenza può regolare la frequenza di commutazione e/o modificare il modello di commutazione al fine diassicurare le prestazioni del convertitore di frequenza.
Specifiche Guida rapida AF-600 FP
DET-759A/I 39
8 8
8.2.1 Fusibili
Si raccomanda di usare fusibili e/o interruttori automatici sul lato di alimentazione come protezione nel caso di un guasto diun componente all'interno del convertitore di frequenza (primo guasto).
NOTA!Questo è obbligatorio per assicurare la conformità con IEC 60364 per CE o NEC 2009 per UL.
AVVISOIl personale e la proprietà devono essere protetti dalle conseguenze di un guasto di un componente all'interno delconvertitore di frequenza.
Protezione del circuito di derivazioneAl fine di proteggere l'impianto contro i pericoli di scosse elettriche o di incendi, tutti i circuiti di derivazione in un impianto,il dispositivo di commutazione, le macchine ecc., devono essere protetti dai cortocircuiti e dalle sovracorrenti confor-memente alle norme nazionali e locali.
NOTA!I consigli dati non coprono la protezione del circuito di derivazione per UL.
Protezione contro i cortocircuiti:GE raccomanda di utilizzare i fusibili/interruttori automatici sotto menzionati per proteggere il personale di servizio e leattrezzature nel caso di un guasto di un componente all'interno del convertitore di frequenza.
Protezione da sovracorrente:Il convertitore di frequenza fornisce una protezione da sovraccarico per limitare le minacce alla vita umana, danni all'attrez-zatura e per evitare il rischio di incendi a causa di un surriscaldamento dei cavi nell'impianto. Il convertitore di frequenza èdotato di una protezione interna contro la sovracorrente (F-43 Limite corrente) che può essere utilizzata per la protezione dasovraccarico a monte (escluse le applicazioni UL). Inoltre possono essere utilizzati fusibili o interruttori automatici pergarantire la protezione da sovracorrente nell'impianto. La protezione da sovracorrente deve essere eseguita sempre nelrispetto delle norme nazionali.
AVVISONel caso di un malfunzionamento, la mancata osservanza delle raccomandazioni potrebbe provocare rischi al personale edanni al convertitore di frequenza o ad altre attrezzature.
Le seguenti tabelle elencano la corrente nominale raccomandata. I fusibili raccomandati sono del tipo gG per potenze daridotte a medie. Per potenze maggiori sono raccomandati fusibili aR. Possono essere utilizzati interruttori a condizione chesiano conformi alle norme nazionali e internazionali e che limitino l'energia al convertitore di frequenza a un valore ugualeo inferiore a quello degli interruttori a norma.Se vengono scelti fusibili/interruttori automatici secondo le raccomandazioni, i possibili danni al convertitore di frequenza silimiteranno soprattutto a danni all'interno dell'unità.
8.2.2 Conformità CE
Fusibili o interruttori automatici sono obbligatori per assicurare la conformità con l'IEC 60364. GE raccomanda l'uso di unaselezione delle seguenti.
I fusibili in basso sono adatti per l'uso su un circuito in grado di fornire 100,000 ampere simmetrici (rms), 240V, 480V, o500V, o 600V in funzione della tensione nominale del convertitore di frequenza. Con i fusibili appropriati , la correntenominale di corto circuito (SCCR) del convertitore di frequenza è pari a 100.000 Arm.
Specifiche Guida rapida AF-600 FP
40 DET-759A/I
88
AF-600 trifase Grandezza consigliata del fusibile Fusibile max raccomandato
[kW] / [HP]
0,75 / 1
gG-16 gG-251,5 / 2
2,2 / 3
3,7 / 5 gG-20 gG-32
5,5 / 7,5
gG-50 gG-637,5 / 10
11 / 15
15 / 20gG-80 gG-125
18,5 / 25
22 / 30 gG-125 gG-150
30 / 40 aR-160 aR-160
37 / 50 aR-200 aR-200
45 / 60 aR-250 aR-250
Tabella 8.1 200-240V, IP20/Open Chassis
AF-600 trifase Grandezza consigliata del fusibile Fusibile max raccomandato
[kW] / [HP]
0,75 / 1
gG-20 gG-321,5 / 2
2,2 / 3
3,7 / 5
5,5 / 7,5
gG-63 gG-807,5 / 10
11 / 15
15 / 20 gG-80 gG-100
18,5 / 25gG-125 gG-160
22 / 30
30 / 40 aR-160 aR-160
37 / 50 aR-200 aR-200
45 / 60 aR-250 aR-250
Tabella 8.2 IP55/Nema 12 e IP66/Nema 4X indoor
Specifiche Guida rapida AF-600 FP
DET-759A/I 41
8 8
AF-600 trifase Grandezza consigliata del fusibile Fusibile max raccomandato
[kW] / [HP]
0,75 / 1
gG-16 gG-251,5 / 2
2,2 / 3
3,7 / 5
5,5 / 7,5gG-20 gG-32
7,5 / 10
11 / 15
gG-50 gG-6315 / 20
18,5 / 25
22 / 30
gG-80 gG-12530 / 40
37 / 50
45 / 60 gG-125 gG-150
55 / 75 aR-160 aR-160
75 / 100aR-250 aR-250
90 / 125
110 / 150 gG-300 gG-300
132 / 200 gG-350 gG-350
160 / 250 gG-400 gG-400
200 / 300 gG-500 gG-500
250 / 350 gG-630 gG-630
315 / 450 aR-700 aR-700
355 / 500
aR-900 aR-900400 / 550
450 / 600
500 / 650aR-1600 aR-1600
560 / 750
630 / 900aR-2000 aR-2000
710 / 1000
800 / 1200aR-2500 aR-2500
1000 / 1350
Tabella 8.3 380-480V, IP20/Open Chassis
Specifiche Guida rapida AF-600 FP
42 DET-759A/I
88
AF-600 trifase Grandezza consigliata del fusibile Fusibile max raccomandato
[kW] / [HP]
0,75 / 1 gG-20 gG-32
1,5 / 2
2,2 / 3
3,7 / 5
5,5 / 7,5
7,5 / 10
11 / 15 gG-50 gG-80
15 / 20
18,5 / 25
22 / 30 gG-80 gG-100
30 / 40
37 / 50 gG-125 gG-160
45 / 60
55 / 75
75 / 100 aR-250 aR-250
90 / 125
110 / 150 gG-300 gG-300
132 / 200 gG-350 gG-350
160 / 250 gG-400 gG-400
200 / 300 gG-500 gG-500
250 / 350 gG-630 gG-630
315 / 450 aR-700 aR-700
355 / 500
aR-900 aR-900400 / 550
450 / 600
500 / 650aR-1600 aR-1600
560 / 750
630 / 900aR-2000 aR-2000
710 / 1000
800 / 1200aR-2500 aR-2500
1000 / 1350
Tabella 8.4 380-480V, IP55/Nema 12
Specifiche Guida rapida AF-600 FP
DET-759A/I 43
8 8
AF-600 trifase Grandezza consigliata del fusibile Fusibile max raccomandato
[kW] / [HP]
0,75 / 1
gG-10 gG-251,5 / 2
2,2 / 3
3,7 / 5
5,5 / 7,5gG-16 gG-32
7,5 / 10
11 / 15
gG-35 gG-6315 / 20
18,5 / 25
22 / 30
gG-63 gG-12530 / 40
37 / 50
45 / 60gG-100 gG-150
55 / 75
75 / 100aR-250 aR-250
90 / 125
Tabella 8.5 525-600V, IP20/Open Chassis
AF-600 trifase Grandezza consigliata del fusibile Fusibile max raccomandato
[kW] / [HP]
0,75 / 1
gG-16 gG-32
1,5 / 2
2,2 / 3
3,7 / 5
5,5 / 7,5
7,5 / 10
11 / 15
gG-35 gG-8015 / 20
18,5 / 25
22 / 30gG-50 gG-100
30 / 40
37 / 50gG-125 gG-160
45 / 60
55 / 75
aR-250 aR-25075 / 100
90 / 125
Tabella 8.6 525-600V, IP55/Nema 12
Specifiche Guida rapida AF-600 FP
44 DET-759A/I
88
AF-600 trifase Grandezza consigliata del fusibile Fusibile max raccomandato
[kW] / [HP]
11 / 15 gG-25
gG-6315 / 20
gG-3218.5 / 25
22 / 30 gG-40
30 / 40gG-63
gG-80
37 / 50 gG-100
45 / 60 gG-80 gG-125
55 / 75 gG-100
gG-16075 / 100gG-125
90 / 125
110 / 150 aR-250 aR-250
132 / 200 aR-315 aR-315
160 / 250aR-350 aR-350
200 / 300
250 / 350 aR-400 aR-400
315 / 450 aR-500 aR-500
400 / 550 aR-550 aR-550
450 / 600aR-700 aR-700
500 / 650
560 / 750aR-900 aR-900
630 / 900
710 / 1000
aR-1600 aR-1600800 / 1150
900 / 1250
1000 / 1350
1200 / 1600 aR-2000 aR-2000
1400 / 1900 aR-2500 aR-2500
Tabella 8.7 525-690V, IP21/Nema 1 and IP55/Nema 12
Specifiche Guida rapida AF-600 FP
DET-759A/I 45
8 8
8.2.3 Conformità NEC e UL
Fusibili o interruttori automatici sono obbilgatori per soddisfare la NEC 2009. Raccomandiamo di usare una selezione deiseguenti
I fusibili in basso sono adatti per l'uso su un circuito in grado di fornire 100,000 Arms (simmetrici), 240V, 480V o 600V infunzione della tensione nominale del convertitore di frequenza. Con la fusione appropriata, la corrente nominale di cortocircuito (SCCR) è pari a 100.000 Arm.
Fusibile max raccomandato
AF-600corrente
monofase
AF-600corrente
trifaseBussmann Bussmann Bussmann Bussmann Bussmann Bussmann
[kW] /[HP]
[kW] /[HP]
Tipo RK1 1) Tipo J Tipo T Tipo CC Tipo CC Tipo CC
0,75 / 1 KTN-R-10 JKS-10 JJN-10 FNQ-R-10 KTK-R-10 LP-CC-10
1,5 / 2 KTN-R-15 JKS-15 JJN-15 FNQ-R-15 KTK-R-15 LP-CC-15
1,5 / 2 2,2 / 3 KTN-R-20 JKS-20 JJN-20 FNQ-R-20 KTK-R-20 LP-CC-20
2,2 / 3 3,7 / 5 KTN-R-30 JKS-30 JJN-30 FNQ-R-30 KTK-R-30 LP-CC-30
3,7 / 5 5,5-7,5 /7,5-10
KTN-R-50 KS-50 JJN-50 - - -
5,5 / 7,5 11 / 15 KTN-R-60 JKS-60 JJN-60 - - -
7,5 / 10 15 / 20 KTN-R-80 JKS-80 JJN-80 - - -
18,5-22 /25-30
KTN-R-125 JKS-125 JJN-125 - - -
15 / 20 30 / 40 KTN-R-150 JKS-150 JJN-150 - - -
23 / 30 37 / 50 KTN-R-200 JKS-200 JJN-200 - - -
45 / 60 KTN-R-250 JKS-250 JJN-250 - - -
Tabella 8.8 200-240V
Fusibile max raccomandato
AF-600
correntemonofase
AF-600
correntetrifase
SIBA LittelfuseFerraz-
ShawmutFerraz-
Shawmut
[kW] /
[HP]
[kW] /
[HP]
Tipo RK1 Tipo RK1 Tipo CC Tipo RK13)
0,75 / 1 5017906-010 KLN-R-10 ATM-R-10 A2K-10-R
1,5 / 2 5017906-016 KLN-R-15 ATM-R-15 A2K-15-R
1,5 / 2 2,2 / 3 5017906-020 KLN-R-20 ATM-R-20 A2K-20-R
2,2 / 3 3,7 / 5 5012406-032 KLN-R-30 ATM-R-30 A2K-30-R
3,7 / 5 5,5-7,5 /
7,5-10
5014006-050 KLN-R-50 - A2K-50-R
5,5 / 7,5 11 / 15 5014006-063 KLN-R-60 - A2K-60-R
7,5 / 10 15 / 20 5014006-080 KLN-R-80 - A2K-80-R
18,5-22 /25-30
2028220-125 KLN-R-125 - A2K-125-R
15 / 20 30 / 40 2028220-150 KLN-R-150 - A2K-150-R
23 / 30 37 / 50 2028220-200 KLN-R-200 - A2K-200-R
45 / 60 2028220-250 KLN-R-250 - A2K-250-R
Tabella 8.9 200-240V
Specifiche Guida rapida AF-600 FP
46 DET-759A/I
88
Fusibile max raccomandato
AF-600monofase
AF-600trifase
Bussmann LittlefuseFerraz-
ShawmutFerraz-
Shawmut
[kW] /
[HP]
[kW] /
[HP]Tipo JFHR22) Tipo JFHR2 Tipo JFHR24) Tipo J
0,75 / 1 FWX-10 - - HSJ-10
1,5 / 2 FWX-15 - - HSJ-15
1,5 / 2 2,2 / 3 FWX-20 - - HSJ-20
2,2 / 3 3,7 / 5 FWX-30 - - HSJ-30
3,7 / 5 5,5-7,5 /
7,5-10
FWX-50 - - HSJ-50
5,5 / 7,5 11 / 15 FWX-60 - - HSJ-60
7,5 / 10 15 / 20 FWX-80 - - HSJ-80
18,5-22 /25-30
FWX-125 - - HSJ-125
15 / 20 30 / 40 FWX-150 L25S-150 A25X-150 HSJ-150
23 / 30 37 / 50 FWX-200 L25S-200 A25X-200 HSJ-200
45 / 60 FWX-250 L25S-250 A25X-250 HSJ-250
Tabella 8.10 200-240V
1) I fusibili KTS della Bussmann possono sostituire i fusibili KTN nei convertitori di frequenza a 240 V.
2) I fusibili FWH della Bussmann possono sostituire i fusibili FWX nei convertitori di frequenza a 240 V.
3) I fusibili A6KR della FERRAZ SHAWMUT possono sostituire i fusibili A2KR nei convertitori di frequenza a 240 V.
4) I fusibili A50X della FERRAZ SHAWMUT possono sostituire i fusibili A25X nei convertitori di frequenza a 240 V.
Fusibile max raccomandato
AF-600monofase
AF-600trifase
Bussmann Bussmann Bussmann Bussmann Bussmann Bussmann
[kW] /
[HP]
[kW] /
[HP]
Tipo RK1 Tipo J Tipo T Tipo CC Tipo CC Tipo CC
0,75 / 1 KTS-R-6 JKS-6 JJS-6 FNQ-R-6 KTK-R-6 LP-CC-6
1,5-2,2 /2-3
KTS-R-10 JKS-10 JJS-10 FNQ-R-10 KTK-R-10 LP-CC-10
3,7 / 5 KTS-R-20 JKS-20 JJS-20 FNQ-R-20 KTK-R-20 LP-CC-20
5,5 / 7,5 KTS-R-25 JKS-25 JJS-25 FNQ-R-25 KTK-R-25 LP-CC-25
7,5 / 10 KTS-R-30 JKS-30 JJS-30 FNQ-R-30 KTK-R-30 LP-CC-30
11-15 /
15-20
KTS-R-40 JKS-40 JJS-40 - - -
18,5 / 25 KTS-R-50 JKS-50 JJS-50 - - -
7,5 / 10 22 / 30 KTS-R-60 JKS-60 JJS-60 - - -
11 / 15 30 / 40 KTS-R-80 JKS-80 JJS-80 - - -
37 / 50 KTS-R-100 JKS-100 JJS-100 - - -
45 / 60 KTS-R-125 JKS-125 JJS-125 - - -
18,5 / 25 55 / 75 KTS-R-150 JKS-150 JJS-150 - - -
37 / 50 75 / 100 KTS-R-200 JKS-200 JJS-200 - - -
90 / 125 KTS-R-250 JKS-250 JJS-250 - - -
Tabella 8.11 380-480V, 125HP e inferiore
Specifiche Guida rapida AF-600 FP
DET-759A/I 47
8 8
Fusibile max raccomandato
AF-600monofase
AF-600 trifase SIBA LittelfuseFerraz-
ShawmutFerraz-
Shawmut
[kW] / [HP] [kW] / [HP] Tipo RK1 Tipo RK1 Tipo CC Tipo RK1
0,75 / 1 5017906-006 KLS-R-6 ATM-R-6 A6K-10-6
1,5-2,2 / 2-3 5017906-010 KLS-R-10 ATM-R-10 A6K-10-R
3,7 / 5 5017906-020 KLS-R-20 ATM-R-20 A6K-20-R
5,5 / 7,5 5017906-025 KLS-R-25 ATM-R-25 A6K-25-R
7,5 / 10 5012406-032 KLS-R-30 ATM-R-30 A6K-30-R
11-15 / 15-20 5014006-040 KLS-R-40 - A6K-40-R
18,5 / 25 5014006-050 KLS-R-50 - A6K-50-R
7,5 / 10 22 / 30 5014006-063 KLS-R-60 - A6K-60-R
11 / 15 30 / 40 2028220-100 KLS-R-80 - A6K-80-R
37 / 50 2028220-125 KLS-R-100 - A6K-100-R
45 / 60 2028220-125 KLS-R-125 - A6K-125-R
18,5 / 25 55 / 75 2028220-160 KLS-R-150 - A6K-150-R
37 / 50 75 / 100 2028220-200 KLS-R-200 - A6K-200-R
90 / 125 2028220-250 KLS-R-250 - A6K-250-R
Tabella 8.12 380-480V, 125HP e inferiore
Fusibile max raccomandato
AF-600monofase
AF-600 trifase Bussmann Ferraz-Shawmut Ferraz-Shawmut Littlefuse
[kW] / [HP] [kW] / [HP] Tipo JFHR2 Tipo J Tipo JFHR21) Tipo JFHR2
0,75 / 1 FWH-6 HSJ-6 - -
1,5-2,2 / 2-3 FWH-10 HSJ-10 - -
3,7 / 5 FWH-20 HSJ-20 - -
5,5 / 7,5 FWH-25 HSJ-25 - -
7,5 / 10 FWH-30 HSJ-30 - -
11-15 / 15-20 FWH-40 HSJ-40 - -
18,5 / 25 FWH-50 HSJ-50 - -
7,5 / 10 22 / 30 FWH-60 HSJ-60 - -
11 / 15 30 / 40 FWH-80 HSJ-80 - -
37 / 50 FWH-100 HSJ-100 - -
45 / 60 FWH-125 HSJ-125 - -
18,5 / 25 55 / 75 FWH-150 HSJ-150 - -
37 / 50 75 / 100 FWH-200 HSJ-200 A50-P-225 L50-S-225
90 / 125 FWH-250 HSJ-250 A50-P-250 L50-S-250
Tabella 8.13 380-480V, 125HP e inferiore
1) I fusibili Ferraz-Shawmut A50QS possono essere sostituiti per fusibili A50P.
Specifiche Guida rapida AF-600 FP
48 DET-759A/I
88
Fusibile max raccomandato
AF-600 Bussmann Bussmann Bussmann Bussmann Bussmann Bussmann
[kW] / [HP] Tipo RK1 Tipo J Tipo T Tipo CC Tipo CC Tipo CC
0,75 / 1 KTS-R-5 JKS-5 JJS-6 FNQ-R-5 KTK-R-5 LP-CC-5
1,5-2,2 / 2-3 KTS-R-10 JKS-10 JJS-10 FNQ-R-10 KTK-R-10 LP-CC-10
3,7 / 5 KTS-R20 JKS-20 JJS-20 FNQ-R-20 KTK-R-20 LP-CC-20
5,5 / 7,5 KTS-R-25 JKS-25 JJS-25 FNQ-R-25 KTK-R-25 LP-CC-25
7,5 / 10 KTS-R-30 JKS-30 JJS-30 FNQ-R-30 KTK-R-30 LP-CC-30
11-15 / 15-20 KTS-R-35 JKS-35 JJS-35 - - -
18,5 / 25 KTS-R-45 JKS-45 JJS-45 - - -
22 / 30 KTS-R-50 JKS-50 JJS-50 - - -
30 / 40 KTS-R-60 JKS-60 JJS-60 - - -
37 / 50 KTS-R-80 JKS-80 JJS-80 - - -
45 / 60 KTS-R-100 JKS-100 JJS-100 - - -
55 / 75 KTS-R-125 JKS-125 JJS-125 - - -
75 / 100 KTS-R-150 JKS-150 JJS-150 - - -
90 / 125 KTS-R-175 JKS-175 JJS-175 - - -
Tabella 8.14 525-600V, 125HP e inferiore
Fusibile max raccomandato
AF-600 SIBA LittlefuseFerraz-
ShawmutFerraz-
Shawmut
[kW] / [HP] Tipo RK1 Tipo RK1 Tipo RK1 Tipo J
0,75 / 1 5017906-005 KLS-R-005 A6K-5-R HSJ-6
1,5-2,2 / 2-3 5017906-010 KLS-R-010 A6K-10-R HSJ-10
3,7 / 5 5017906-020 KLS-R-020 A6K-20-R HSJ-20
5,5 / 7,5 5017906-025 KLS-R-025 A6K-25-R HSJ-25
7,5 / 10 5017906-030 KLS-R-030 A6K-30-R HSJ-30
11-15 / 15-20 5014006-040 KLS-R-035 A6K-35-R HSJ-35
18,5 / 25 5014006-050 KLS-R-045 A6K-45-R HSJ-45
22 / 30 5014006-050 KLS-R-050 A6K-50-R HSJ-50
30 / 40 5014006-063 KLS-R-060 A6K-60-R HSJ-60
37 / 50 5014006-080 KLS-R-075 A6K-80-R HSJ-80
45 / 60 5014006-100 KLS-R-100 A6K-100-R HSJ-100
55 / 75 2028220-125 KLS-R-125 A6K-125-R HSJ-125
75 / 100 2028220-150 KLS-R-150 A6K-150-R HSJ-150
90 / 125 2028220-200 KLS-R-175 A6K-175-R HSJ-175
Tabella 8.15 525-600V, 125HP e inferiore
1) I fusibili 170M Bussmann mostrati utilizzano l'indicatore visivo -/80. È possibile sostituirli con i fusibili conindicatore -TN/80 tipo T, -/110 o TN/110 tipo T di ugual dimensione e amperaggio.
Specifiche Guida rapida AF-600 FP
DET-759A/I 49
8 8
AF-600 trifase Bussmann Bussmann Bussmann SIBA Littlefuse Ferraz-Shawmut Ferraz-Shawmut
[kW] / [HP] Tipo RK1 Tipo J Tipo T Tipo RK1 Tipo RK1 Tipo RK1 Tipo J
11 / 15 KTS-R-30 JKS-30 JJS-30 5017906-030 KLS-R-030 A6K-30R HST-30
15 / 20 KTS-R-35 JKS-35 JJS-35 5014006-040 KLS-R-035 A6K-35R HST-35
18,5 / 25 KTS-R-45 JKS-45 JJS-45 5014006-050 KLS-R-045 A6K-45R HST-45
22 / 30 KTS-R50 JKS-50 JJS-50 5014006-050 KLS-R-50 A6K-50R HST-50
30 / 40 KTS-R-60 JKS-60 JJS-60 5014006-063 KLS-R-060 A6K-60R HST-60
37 / 50 KTS-R-80 JKS-80 JJS-80 5014006-080 KLS-R-075 A6K-80R HST-80
45 / 60 KTS-R-100 JKS-100 JJS-100 5014006-100 KLS-R-100 A6K-100R HST-100
55 / 75 KTS-R125 JKS-125 JJS-125 2028220-125 KLS-125 A6K-125R HST-125
75 / 100 KTS-R150 JKS-150 JJS-150 2028220-150 KLS-150 A6K-150R HST-150
90 / 125 KTS-R175 JKS-175 JJS-175 2028220-200 KLS-175 A6K-175R HST-175
Tabella 8.16 525-690, IP21 / Nema 1 e IP55 / Nema 12
Specifiche Guida rapida AF-600 FP
50 DET-759A/I
88
Fusibile max raccomandato
AF-600 Bussmann PNEsterno
alternatoBussmann PN
Esternoalternato
Bussmann PN
EsternoalternatoSiba PN
Esterno alternatoLittlefuse PN
Esternoalternato
Ferraz-Shawmut PN
Esterno alternatoFerraz-Shawmut PN
[kW] /
[HP]Tipo JFHR2 Tipo JFHR2 Tipo T/JDDZ Tipo JFHR2 Tipo JFHR2 Tipo JFHR2
110 /150
170M3017 FWH-300 JJS-300 2028220-315 L50-S-300 A50-P-300
132 /200
170M3018 FWH-350 JJS-350 2028220-315 L50-S-350 A50-P-350
160 /250
170M4012 FWH-400 JJS-400 206xx32-400 L50-S-400 A50-P-400
200 /300
170M4014 FWH-500 JJS-500 206xx32-500 L50-S-500 A50-P-500
250 /
350
170M4016 FWH-600 JJS-600 206xx32-600 L50-S-600 A50-P-600
315 /
450
170M4017 20 610 32.700 6.9URD31D08A0700
355 /500
170M6013 22 610 32.900 6.9URD33D08A0900
400 /550
170M6013 22 610 32.900 6.9URD33D08A0900
450 /600
170M6013 22 610 32.900 6.9URD33D08A0900
500 /650
170M7081
560 /
750
170M7081
630 /900
170M7082
710 /1000
170M7082
800 /1200
170M7083
1000 /1350
170M7083
Tabella 8.17 380-480V, oltre 125HP
AF-600 Bussmann PN Potenza nominale Alternate Siba PN
[kW] / [HP]
500 / 650 170M8611 1100A, 1000V 20 781 32.1000
560 / 750 170M8611 1100A, 1000V 20 781 32.1000
630 / 900 170M6467 1400A, 700V 20 681 32.1400
710 / 1000 170M6467 1400A, 700V 20 681 32.1400
800 / 1200 170M8611 1100A, 1000V 20 781 32.1000
1000 / 1350 170M6467 1400A, 700V 20 681 32.1400
Tabella 8.18 380-480V, dimensione telaio 6, fusibili collegamento CC modulo inverter
Specifiche Guida rapida AF-600 FP
DET-759A/I 51
8 8
AF-600Bussmann PN Esterno alternato
Siba PNEsterno alternato
Ferraz-Shawmut PN
[kW] / [HP] Tipo JFHR2 Tipo JFHR2
132 / 200 170M3017 2061032,315 6.9URD30D08A0315
160 / 250 170M3018 2061032,35 6.9URD30D08A0350
200 / 300 170M4011 2061032,35 6.9URD30D08A0350
250 / 350 170M4012 2061032,4 6.9URD30D08A0400
315 / 450 170M4014 2061032,5 6.9URD30D08A0500
400 / 550 170M5011 2062032,55 6.9URD32D08A0550
450 / 600 170M4017
500 / 650 170M4017 20 610 32.700 6.9URD31D08A0700
560 / 750 170M6013 20 610 32.700 6.9URD31D08A0700
630 / 900 170M6013 22 610 32.900 6.9URD33D08A0900
710 / 1000 170M7081 22 610 32.900 6.9URD33D08A0900
800 / 1150 170M7081
900 / 1250 170M7081
1000 / 1350 170M7081
1200 / 1600 170M7082
1400 / 1900 170M7083
Tabella 8.19 525-690V, oltre 125HP
AF-600 Bussmann PN Potenza nominale Alternate Siba PN
[kW] / [HP]
710 / 1000 170M8611 1100A, 1000V 20 781 32.1000
800 / 1150 170M8611 1100A, 1000V 20 781 32.1000
900 / 1250 170M8611 1100A, 1000V 20 781 32.1000
1000 / 1350 170M8611 1100A, 1000V 20 781 32.1000
1200 / 1600 170M8611 1100A, 1000V 20 781 32.1000
1400 / 1900 170M8611 1100A, 1000V 20 781 32.1000
Tabella 8.20 525-690V, dimensione telaio 6, fusibili collegamento CC modulo inverter
*I fusibili 170M Bussmann mostrati utilizzano l'indicatore visivo -/80. È possibile sostituirli con i fusibili con indicatore -TN/80 tipo T, -/110 oTN/110 tipo T di ugual dimensione e amperaggio per l'utilizzo esterno
**È possibile utilizzare qualsiasi fusibile UL di almeno 500 V con il valore nominale di corrente adatto per soddisfare i requisiti UL.
Specifiche Guida rapida AF-600 FP
52 DET-759A/I
88
9 Morsetto e filo elettrico applicabile
9.1 Cavi
Pote
nza
[kW
/ H
P]Cu
stod
ia
Rete
Mot
ore
Cond
ivis
ione
del
car
ico
Fren
oTe
rra*
200-
240V
380-
480V
525-
600V
525-
690V
Copp
ia d
ise
rrag
gio
[Nm
/ in
-lb
s]
Dim
ensi
one
del f
iloel
ettr
ico
[mm
2(A
WG
)]
Copp
ia d
ise
rrag
gio
[Nm
/ in
-lb
s]
Dim
ensi
one
del f
iloel
ettr
ico
[mm
2 (A
WG
)]
Copp
ia d
ise
rrag
gio
[Nm
/ in
-lb
s]
Dim
ensi
one
del f
iloel
ettr
ico
[mm
2(A
WG
)]
Copp
ia d
ise
rrag
gio
[Nm
/ in
-lb
s]
Dim
ensi
one
del f
iloel
ettr
ico
[mm
2(A
WG
)]
Copp
ia d
ise
rrag
gio
[Nm
/ in
-lb
s]
0,75
-2,2
kW1-
3HP
0,75
-3,7
kW1-
5HP
IP20
1,8
/ 16
4 (1
0)
1,8
/ 16
4 (1
0)1,
8 /
164
(10)
1,8
/ 16
4 (1
0)
3 /
27
3,7k
W 5
HP
5,5-
7,5k
W7,
5-10
HP
0,75
-7,5
kW1-
10H
P
IP20
0,75
-3,7
kW1-
5HP
0,75
-7,5
kW1-
10H
P0,
75-7
,5kW
1-10
HP
IP
55 o
IP66
5,5-
11kW
7,5-
15H
P11
-18,
5kW
15-2
5HP
11-1
8,5k
W15
-25H
P
IP20
16 (6
)16
(6)
16 (6
)16
(6)
5,5-
11kW
7,5-
15H
P11
-18,
5kW
15-2
5HP
11-1
8,5k
W15
-25H
P
IP55
oIP
661,
5 /
141,
5 /
14
15-1
8,5k
W20
-25H
P22
-37k
W30
-50H
P22
-37k
W30
-50H
P
IP20
4,5
/ 40
35 (2
)4,
5 /
4035
(2)
4,5
/ 40
35 (2
)4,
5 /
4035
(2)
15kW
20H
P22
-30k
W30
-40H
P22
-30k
W30
-40H
P11
-30k
W15
-40H
PIP
55 o
IP66
3,7
/ 33
3,7
/ 33
22-3
0kW
30-4
0HP
45-5
5kW
60-7
5HP
45-5
5kW
60-7
5HP
IP
2010
/ 8
950
(1)
10 /
89
50 (1
)10
/ 8
950
(1)
10 /
89
50 (1
)
18,5
-30k
W25
-40H
P37
-55k
W50
-75H
P37
-55k
W50
-75H
P
IP55
oIP
6690
(3/0
)90
(3/0
)90
(3/0
)90
(3/0
)
37-4
5kW
50-6
0HP
75-9
0kW
100-
125H
P75
-90k
W10
0-12
5HP
IP
2014
/ 1
24
150
(300
mcm
)14
/ 1
24
150
(300
mcm
)14
/ 1
2495
(4/0
)14
/ 1
2495
(4/0
)
37-4
5kW
50-6
0HP
75-9
0kW
100-
125H
P75
-90k
W10
0-12
5HP
37-9
0kW
50-1
25H
PIP
55 o
IP66
120
(4/0
)12
0 (4
/0)
120
(4/0
)12
0 (4
/0)
11
0-13
2kW
150-
200H
P
110-
160k
W15
0-25
0HP
tutt
i
19 /
168
2x70
(2x2
/0)
19 /
168
2x70
(2x2
/0)
9,5
/ 84
2x70
(2x2
/0)
9,5
/ 84
2x70
(2x2
/0)
19 /
168
16
0-25
0kW
250-
350H
P
200-
400k
W30
0-55
0HP
tutt
i2x
185
(2x3
50m
cm)
2x18
5(2
x350
mcm
)2x
185
(2x3
50m
cm)
2x18
5(2
x350
mcm
)
315-
450k
W45
0-60
0HP
45
0-63
0kW
600-
900H
Ptu
tti
4x24
0(4
x500
mcm
)4x
240
(4x5
00m
cm)
19 /
168
4x24
0(4
x500
mcm
)
50
0-71
0kW
650-
1000
HP
71
0-90
0kW
1000
-125
0HP
tutt
i8x
240
(8x5
00m
cm)
8x15
0(8
x300
mcm
)4x
120
(4x2
50m
cm)
4x18
5(4
x350
mcm
)
80
0-10
00kW
1200
-135
0HP
10
00-1
400k
W13
50-1
900H
Ptu
tti
12x1
50(1
2x30
0mcm
)6x
185
(6x3
50m
cm)
* M
assi
ma
dim
ensi
one
del c
avo
sec
ondo
il c
odic
e na
zion
ale
Morsetto e filo elettrico a... Guida rapida AF-600 FP
DET-759A/I 53
9 9
AF-600 FPTM
Fan & Pump Drive Quick GuideGuia rapidaKurzanleitungGuide rapideGuida rapida
130R0288 *MG14E16S*
DET-759A/S/D/F/I
GE
GE EnergyIndustrial Solutions
© Copyright GE Industrial Solutions 2011
GE imagination at work
@
Industrial Solutions (formerly Power Protection),a division of GE Energy, is a fi rst class Europeansupplier of low and medium voltage productsincluding wiring devices, residential andindustrial electrical distribution components,automation products, enclosures and switchboards. Demand for the company’s products comes from wholesalers, installers, panelboard builders, contractors, OEMs and utilities worldwide.
www.ge.com/ex/industrialsolutions
BelgiumGE Industrial BelgiumNieuwevaart 51B-9000 GentTel. +32 (0)9 265 21 11
FinlandGE Energy Industrial SolutionsKuortaneenkatu 2FI-00510 HelsinkiTel. +358 (0)10 394 3760
FranceGE Energy Industrial SolutionsParis Nord 213, rue de la PerdrixF-95958 Roissy CDG CédexTel. +33 (0)800 912 816
GermanyGE Energy Industrial SolutionsVor den Siebenburgen 2D-50676 KölnTel. +49 (0)221 16539 - 0
HungaryGE Hungary Kft .Vaci ut 81-83.H-1139 BudapestTel. +36 1 447 6050
South AfricaGE Energy Industrial SolutionsUnit 4, 130 Gazelle AvenueCorporate Park Midrand 1685P.O. Box 76672 Wendywood 2144 Tel. +27 11 238 3000
SpainGE Energy Industrial SolutionsP.I. Clot del Tufau, s/nE-08295 Sant Vicenç de CastelletTel. +34 900 993 625
United Arab EmiratesGE Energy Industrial Solutions1101, City Tower 2, Sheikh Zayed RoadP.O. Box 11549, DubaiTel. +971 43131202
United KingdomGE Energy Industrial SolutionsHoughton CentreSalthouse RoadBlackmillsNorthamptonNN4 7EXTel. +44 (0)800 587 1239
ItalyGE Energy Industrial SolutionsCentro Direzionale ColleoniVia Paracelso 16Palazzo Andromeda B1I-20041 Agrate Brianza (MB)Tel. +39 2 61 773 1
NetherlandsGE Energy Industrial SolutionsParallelweg 10Nl-7482 CA HaaksbergenTel. +31 (0)53 573 03 03
PolandGE Power ControlsUl. Odrowaza 1503-310 WarszawaTel. +48 22 519 76 00
PortugalGE Energy Industrial SolutionsRua Camilo Castelo Branco, 805Apartado 27704401-601 Vila Nova de GaiaTel. +351 22 374 60 00
RussiaGE Energy Industrial Solutions27/8, Electrozavodskaya streetMoscow, 107023Tel. +7 495 937 11 11
United States of AmericaGE Energy Industrial Solutions41 Woodford AvenuePlainville, CT 06062
Recommended