3EF005-1201E
Notice for specificationsI.U.=Indoor Unit O.U.=Outdoor Unit Qu=Quiet * =Not decided yet•Specifications and design are subject to change without notice for future improvement.•For further details, please check with our authorised dealer.•Cooling/Heating capacities are based on the following conditions.
Cooling Indoor temp.Outdoor temp.
: 27˚C DB/19˚C WB: 35˚C DB/24˚C WB Heating : 20˚C DB/15˚C WB
: 7˚C DB/6˚C WBIndoor temp.Outdoor temp.
1116, Suenaga, Takatsu-ku, Kawasaki 213-8502, Japanhttp://www.fujitsu-general.com/
•Actual products’ colors may be different from the colors shown in this printed material.
Copyright© 2008-2012 Fujitsu General Limited. All rights reserved.
•“ ” and “ ” are worldwide trademarks of FUJITSU GENERAL LIMITED and are registered trademarks in Japan and other countries or areas.•“ ” is a worldwide trademark of FUJITSU GENERAL LIMITED•Other company and product names mentioned herein may be registered trademarks, trademarks or trade names of their respective owners.
Fujitsu General (Thailand) Co., Ltd.
ISO 9001Certified number : 01 100 89394
ISO 14001Certified number : 01 104 9245101
Fujitsu General (Shanghai) Co., Ltd.
ISO 9001Certified number : 01 100 79269
ISO 14001Certified number : 272043
Fujitsu General Central Air-conditioner (Wuxi) Co., Ltd.
ISO 9001Certified number : 00608Q11061R2M
ISO 14001Certified number : 00609E20454R2M
The Intelligent Choice in Comfort
003003002
Fujitsu General creates high-quality and environmentally-friendly products that provide good comfort in accordance with our basic policy to a “create comfortable environment” by utilizing the air conditioning technology and creativity we have fostered over many years.
The Headquarters R&D Center is equipped with a wide range of testing equipment envisioning a variety of operating conditions. This includes a testing tower with a 60m height difference for buildings. We provide high quality & reliable products that meet the customers’ needs from all over the world through this advanced R&D center and 6 production companies based in China and Thailand.
• FUJITSU GENERAL AMERICA, INC.
• FUJITSU GENERAL DO BRASIL LTDA.
• FUJITSU GENERAL (ASIA) PTE. LTD.
• Sales Companies
• Head Office
• Manufacturing Companies
• FUJITSU GENERAL (THAILAND) CO., LTD. • FUJITSU GENERAL ENGINEERING (THAILAND) CO., LTD.• FGA (THAILAND) CO., LTD.
• FUJITSU GENERAL LIMITED
• FUJITSU GENERAL ORIENT INTERNATIONAL ELECTRONICS SALES (SHANGHAI) CO., LTD.
• FUJITSU GENERAL (SHANGHAI) CO., LTD.• F.G.L.S. ELECTRIC CO., LTD.
• FUJITSU GENERAL CENTRAL AIR-CONDITIONER (WUXI) CO., LTD.
• FUJITSU GENERAL (EURO) GmbH• FUJITSU GENERAL (U.K.) CO., LIMITED• FG EUROFRED LIMITED• WAVE AIR CONDITIONING LIMITED
• FUJITSU GENERAL (TAIWAN) CO., LTD.
• FUJITSU GENERAL NEW ZEALAND LIMITED
• FUJITSU GENERAL (AUST.) PTY LIMITED
• FUJITSU GENERAL (MIDDLE EAST) FZE
R&D CenterAnd 60 m Height Difference Testing Tower
FGA (Thailand) Co., Ltd.
Fujitsu General (Shanghai) Co., Ltd.
Fujitsu General Central Air-conditioner (Wuxi) Co., Ltd.
F.G.L.S. Electric Co., Ltd.
Fujitsu General (Thailand) Co., Ltd.Fujitsu General Engineering (Thailand) Co., Ltd.
003005004
Small VRF series
Hi-spec Design model
Air to Water system
VRF combination type
*1. Announced 1991. In room air conditioner for the home (our company’s investigation)*2. Announced 1994. In room air conditioner for the home (our company’s investigation)*3. Announced 2002. In room air conditioner for the home (our company’s investigation)
Air conditioner with the world’s first automatic self-cleaning filter system
(Suppliers)
(Factories)(Home)
Material and part manufacturing
Product development and design
Product manufacturing
Use
Waste and recycle
Environmental Management
System
Powerdiffuser
Lambda heat exchanger
*1 *2 *3
TM
The Fujitsu General Group strives for business activities that achieve harmony between contributing to protecting the global environment and company activities while making environmental protection activities an important issue in company management. The Fujitsu General Group is working to improve its environmental friendliness by building an environmental management system (EMS); taking environmental protection measures throughout the product life cycle of materials procurement, product development and design, manufacturing, and recycling; and by taking the environment into consideration during business activities such as by saving energy and resources and reducing waste.
007006
Sub-cooler Heat exchanger
Optimized Inverter Control
DC fan motor realizes high power, wide operation range, and high efficiency.
DC Fan MotorDC Twin Rotary Compressor
In case of cooling circuit
The high efficiency DC inverter type "2-cylinder rotary compressor" is used for large capacity of split system. It has achieved higher energy efficiency compared with equal class of compressors by optimizing the structure inside the compressor.
High performance sub-cool heat exchanger
High Efficiency Heat Exchanger
Heat exchange performance is substantially improved by thin and high-density heat exchanger and multi-path efficiency technology.
High density multi-path heat exchanger
DC Fan Motor
DC Fan Motor
Indoor unit Outdoor unit
All DC Inverter Technology
For RAC For VRF
Inverter Control Base
DC Compressor
Indoor unitOutdoor unit
I-PAM (IPM*+PAM)Inverter control
I-PAM inverter control is a technology which reduces loss by adjusting the current waveform to a better sine waveform. This promotes the effective use of the input power supply to attain high performance.
Compressor
Heat exchanger
Over 90% of actual operation time, air conditioners are operated at partial capacity instead of rated capacity.We focused on high seasonal efficiency by all DC inverter control and high efficiency technology.
Fujitsu General air conditioners bring quality air to people and provide true comfort, energy saving, and clean environment through our core technology
It becomes more powerful with the newly developed high efficient compressor motor control.
More compact than conventional models
Vector I-PAM
Ø5mm
20mm
Refrigerant
HighHigh
CO
PC
OP
(%)(%)Heating part loadHeating part load
2525 5050 7575 100100
Conventional inverter control
I-PAM inverter control
Multi-path (image)
Frequency operation range
Higher performance achieved by mounting of counter type bypass circuit. (Large multi type, VRF)
V-PAM inverter control reduces the effects of magnetic flux and increases the maximum speed and efficiency of the compressor by vector control technology. With this technology, further miniaturization, higher efficiency, and better performance are attained.
IPM*: Intelligent Power Module
V-PAM (Vector+I-PAM)Inverter control
Temp.In addition, the voltage is raised at the start of operation and fast comfort is attainable by more powerful operation.
SettingTemp.
Time
I-PAM Inverter
Conventional Inverter
009008
(24/30)
(24/30)
Automatic filter cleaner
Normal set temp. range Limit set temp. rangeTime
30°C
10
(˚C)
15 16 17 18
33 32 31 30 29
(˚C)
Vertical airflow
Horizontal airflow
Air conditioning load factor
Capacity
Operating sound
Time
100%
58dB
0
0
Heat load
Quiet priority low noise mode
Economy operation
Normal operationSettingtemperature
*1
*1. Announced September 9, 2002. In room air conditioner for the home (Our company’s investigation)
Power diffuser
Lambda heat exchanger
Economical and comfortable air conditioning environment is realized by various energy saving technologies such as sensor technology, original automatic filter cleaning function, and economical set temperature control, etc.
Human sensor catches movements of people in a room, and operates with lower capacity when people leave the room, which can save electric expense. When people come back to the room, it returns to previous operating mode.
Energy Saving ControlAutomatic filter cleaning
This function allows an energy saving of more than 25% a year and maintains a smooth airflow by preventing the filters from being clogged with dust.
Quick ComfortPowerful operation Outdoor unit low noise operation
Continuous operation by maximum air flow and maximum compressor speed after a certain period of time allows the temperature to reach the setting temp. quickly.Economy operation
Limits the maximum operation current, and the power consumption is cut down and the maximum load is suppressed.
Room temperature set point limitation
The minimum and maximum temperature range can be set giving further energy saving while considering the comfort of the occupants.
10°C Heat operation
When you leave, minimum heating operation is performed to maintain the room temperature. (Maintain at 10°C)
Human sensor control
Precision wind direction control is realized and ventilation efficiency is also improved by 3 technologies. Our airflow control makes your environment more comfortable.
Comfort Airflow
High heating capacity is realized even at low outdoor temperature by mounting the large heat exchanger or large DC rotary compressor and developing the high performance inverter PCB
Powerful Heating
Users can choose low noise levels, depending on the installation environment. The operation time can be set using the timer.
Quiet Control
+2°C *Max. 30°CCooling / Dry
Heating
-4°C *Max. 16°C
Saving operation
Set temp.
Set temp.
Human sensor
SAVE ! AUTORESTART
Normal operation Normal operation
Human sensor's coverage
6m
90° 100°
6mLarge fan
High performance inverter PCB
Large heat exchanger
Large intake
Double-blow flap
10°C
20°C
“10°C HEAT” Button ON
Setting temp.
Normal mode
Time
Tem
pera
ture
Powerful operation mode
Hea
ting
capa
city
(kW
)
Ambient temperature (°C)
High
-7 High
Keeping rated capacity
Large DC rotary compressor
Indoor unit operation START
Judgment(Over 20 min.)
Fujitsu General realizes a comfortable environment at all times by developing original air flow control. In addition, we pursue the various control technologies to provide you with a pleasant air-conditioned life.
011010
Clean Filter
Individual Friendly Control Central Management Control
Wireless remote controller
New slim wirelessremote controller System controllerTouch panel
controller
Organic coating fin used heat exchanger
Air conditioner filter features
Deodorant and anti-bacteria filter can resolve the constituent of bad smell by the pre-filter mixed with special ceramic powder which gives near infrared rays effect.
Deodorant & Anti-bacteria Filter
Pre-filter
H+
O-
OH-
O+
Badsmell
Badsmell
*1
We are producing control systems that provide greater convenience for both individual and centralized control with operability suitable for the application and such features as one-touch selection and a range of batch control operation methods.
Fujitsu General is using ergonomics to expand the use of user friendly designs such as easy-to-read large LCD displays, easy-to-operate buttons, and displays with easily recognizable colors and icons.
Clean FunctionAutomatic filter cleaning
Drives away the bacteria and refreshes the air.The dirt and dust are bacteria-eliminated by photocatalytic filterHigh density air filter surely catches the dust in the air. The collected dust is automatically removed, and the air is always cleaned in a clean state.
Long-life Ion Deodorization Filter Apple-catechin Filter
Fine dust, invisible mold spores, and harmful microorganisms are absorbed onto the filter by static electricity, and further growth is inhibited and deactivated by the polyphenol extracted from apples.
Central & Individual ControlUser-friendly operationMultiple language support
Perfect comfort pursued by removal of dust and odors and bacteria, etc. in the air, intake of fresh air, and other clean air conditioning technologies which always take health into consideration.
Drives away the bacteria and refreshes the air.The dirt and dust are bacteria-eliminated by photocatalytic filterHigh density air filter surely catches the dust in the air. The collected dust is automatically removed, and the air is always cleaned in a clean state.
*1. Announced September 9, 2002. In room air conditioner for the home (Our company’s investigation)
013012
Approach to the New Energy Efficiency Standard
*1. By 2020, CO2 emission -20%, Renewable energy share 20%, Primary energy use -20%*2. Under development (Dec.2011)*3. New energy labeling requirement (EU) 626/2011
*4. Enforcement on January 1, 2013 Air conditioners up to 12 kW
Our models are reaching the "Class A" ranking, the highest energy efficiency level that is now shown on energy labels in Europe.
New Energy Labeling Requirement (EU) 626 / 2011
Strengthened heating performance and efficiency, low noise level, etc.
• Performance notation based on multiple points calculations that better match the actual operation
• Energy labeling revision• Raising of the CLASS A level
Current Energy Label New Energy Label *4
AO-AS-
A
There are seven classifications of energy efficiency, from A to G. The most efficient level is "A" and the least efficient level is "G".
Current Energy labeling points New Energy labeling points
Operatingpower consumption
Seasonal efficiency
SEER SCOP
• Integrates part load capacity• Optimized for several rating temperatures
Rated efficiency
• Full capacity• One point temperature condition
EER COP
• Operating power consumption• Standby power consumption• Crank case heater• Thermo off
New criteria
Sound pressure level
Annual efficientoperation
Reduce total power consumption
Low noise products
Total power consumption
• Three climate zone for heating (Average zone : mandatory) (Warmer and colder zone are optional)• Seasonal efficiency • Sound power level
From residential to commercial useDevelopment of a series of new Class A products
FUJITSU GENERAL provides the products which will meet the EU action plan 20/20/20*1 and the implementing measures for air-conditioners of the ECO-Design Directive (ErP)*2
• FUJITSU GENERAL is focusing on the development of high seasonal efficiency products that are adapted to meet the new energy efficiency requirements*3 starting from January 2013 and reinforcement demands starting from 2014. Highest energy class products are already available today.
Sound power level
015014
Auto louver grill (Option) Auto louver grille provides comfort and efficient heating with louver controlled ductable outlet.
High COP & Powerful Heating model 9 / 12
High COP model 7 / 9 / 12 / 14
Thin & Slim Design with High COP & Powerful Heating
Simple flat design matches to various interior and
energy saving operation is realized by Human Sensor*.
Our advanced technology makes your life comfortable.*LT series only
New Small VRF System for light commercial and home use
Slim Duct
• Height 198mm Slim design with drain pump• Flexible installation• Selectable with a wide range of static pressure• Dual concealed type56-57 page
12 / 14 18
Design model Slim Duct type
26-29 page
Small VRF system 4 / 5 / 6 HP
Large VRF system (Heat Recovery type)
• Wide lineup of indoor units and controllers to support a variety of properties.• High energy saving• Powerful heating & Low noise design• More design flexibility110-115 page
• High energy saving & More comfort• Space saving & High efficiency combination
ForLarge Homes
ForSmall Office
Compact Outdoor Unit
FeatureRelease
017016
174 Feature Explanation
170 Deodoriser
162 Air to Water
160 Window
156 Energy Recovery Ventilator
152 Optional Parts for VRF
098 VRF
094 Optional Parts for Split & Multi Split
068 Multi Split
022 Split
019018
Split
AOYG18LAC2
AOYG18LAT3
AOYG24LAT3
AOYG30LAT4
AOYG36LATT
AOYG45LATT
AOYG45LAT8
AOYG54LATT
AJYA90EATAAJYA90TATA
AOYG14LAC2
Multi Split
Ceiling Wall024 page
2.07
2.6 3.512
4.114
5.318
Capacity (kW)Model Code
10.636
8.830
7.124
13.245
15.854
17.660
26.4909
AWYZ14LB AWYZ18LB AWYZ24LB
026 page
Wall Mounted
030 page
WallMounted
072 pageUp to 2 Units
072 pageUp to 3 Units
072 pageUp to 4 Units
092 pageBig Multi
090 page
Simultaneous Multi Twin / Triple
038 pageFloor
040 page
Compact Cassette /Cassette
048 pageFloor/Ceiling Universal
052 pageCeiling
056 pageSlim Duct
058 page
Compact Duct /Medium Static Pressure Duct
064 page
High Static Pressure Duct
Constant
Constant
Constant
Constant
Constant
074 pageUp to 8 Units
Constant
Constant
Constant
ASYG12LUASYG09LU
ASYG09LT ASYG12LT
ASYG12LE ASYG14LE
ASYG14LU
ASYG09LEASYG07LE
ASYG07LU
ASY12UC
ASYG18LF
ASY18UB
AGYF09LA AGYF12LA AGYF14LA
AUYG12LVLB AUYG14LVLB AUYG18LVLB
AUY18UB
ABYF24LB
AUYF24LB
AUY25UU
ABY24UB
AUY30UU AUY36UU AUY45UU AUY54UU
AUYA30LB AUYA36LB/AUYG36LR AUYA45LC/AUYG45LR AUYA54LC/AUYG54LR
ABYA30LB ABYA36LB/ABYG36LR ABYA45LC/ABYG45LR ABYA54LC/ABYG54LR
ASYG24LF
ASY24UB
ASYG30LF
ASY30UBASY9UCASY7UB
ABYG18LVTB
ABY18UB
ARYF24LB
ABY30UB ABY36UB ABY45UB ABY54UB
ARY60UU ARY90TL
ARYA30LB ARYA36LB/ARYG36LM ARYA45LC/ARYG45LM
ARY18UU ARY25UU ARY30UU ARY36U(1)/ARY36UU ARY45UU
AJYA90EATBAJYA90TATB
Individual
Simultaneous
High COP &Powerfulheating
High COP
Standard
ARYG12LLTB ARYG14LLTB ARYG18LLTB
ARYC45LC/ARYG45LH ARYC54LC/ARYG54LH
3phase 3phase 3phase
3phase 3phase
3phase 3phase
3phase 3phase
3phase3phase3phase
3phase
021020
AJYA90LALH
V R F
Deodoriser
DASY30S
172 page
Capacity (m3/h)Model Code
3.030
Window
AFY16UA
Capacity (kW)Model Code
4.616
Constant
160 page
22.48
28.010
33.512
40.014
45.016
50.418
55.920
61.522
67.024
Capacity (kW) 85.030
90.032
73.526
78.528
95.034
100.536
107.038
112.040
118.542
123.544
130.046
135.048
15.56
14.05
11.24HP
AJYA54LALHAJYA45LALHAJYA36LALH
AO90MPCMF
J-II series Heat Pump
110 page
S series Heat Recovery
100 page
Set Model AJYA72LALHAJYA72LALH
AJYA90LALH AJY108LALHAJY108LALH
AJY126LALH AJY144LALHAJY126LALH AJY144LALH
AJY144LALHHAJYA72LALH
AJYA72LALH
AJY162LALHAJYA90LALH
AJYA72LALH
AJY180LALHAJY108LALH
AJYA72LALH
AJY198LALHAJY108LALH
AJYA90LALH
AJY216LALHAJY108LALH
AJY108LALH
AJY234LALHAJY126LALH
AJY108LALH
AJY252LALHAJY144LALH
AJY108LALH
AJY270LALHAJY144LALH
AJY126LALH
AJY288LALHAJY144LALH
AJY144LALH
Unit 1Unit 2Unit 3
Set ModelUnit 1Unit 2Unit 3
V-II series Space savingHeat Pump
116 page
V-II series Energy efficiencyHeat Pump
116 page
AJY306LALHAJY108LALH
AJY108LALH
AJYA90LALH
AJY324LALHAJY108LALH
AJY108LALH
AJY108LALH
AJY342LALHAJY126LALH
AJY108LALH
AJY108LALH
AJY360LALHAJY144LALH
AJY108LALH
AJY108LALH
AJY378LALHAJY144LALH
AJY126LALH
AJY108LALH
AJY396LALHAJY144LALH
AJY144LALH
AJY108LALH
AJY414LALHAJY144LALH
AJY144LALH
AJY126LALH
AJY432LALHAJY144LALH
AJY144LALH
AJY144LALH
AJY198LALHHAJY126LALHH
AJYA72LALH
AJY216LALHHAJYA72LALH
AJYA72LALH
AJYA72LALH
AJY234LALHHAJYA90LALH
AJYA72LALH
AJYA72LALH
AJY252LALHHAJY108LALH
AJYA72LALH
AJYA72LALH
AJY270LALHHAJY126LALH
AJYA72LALH
AJYA72LALH
AJY288LALHHAJY108LALH
AJY108LALH
AJYA72LALH
AJY306LALHHAJY126LALH
AJY108LALH
AJYA72LALH
AJY324LALHHAJY126LALH
AJY126LALH
AJYA72LALH
AJY360LALHHAJY126LALH
AJY126LALH
AJY108LALH
AJY378LALHHAJY126LALH
AJY126LALH
AJY126LALH
AJY396LALHHAJY144LALH
AJY126LALH
AJY126LALH
11 13128
14 16155
WSYA128DA WSYA155DAAOYA45LBTL AOY54LJBYL
Air to Water6
65880
Capacity (kW) 550Model Code
Indoor UnitOutdoor Unit
High Powermodel
164 page
164 page
Indoor UnitOutdoor Unit
WSYA080DAWSYA065DAWSYA050DAAOYA24LALLAOYA18LALLAOYA18LALL
Comfortmodel
164 page
Compactmodel
165 page
Indoor UnitOutdoor Unit
WPYA080LA
WSYK160DA9WOYK112LAT
WSYK160DA9 WSYK160DA9WOYK140LAT
WSYG140DB6WOYG112LBT
WSYG140DB6WOYG140LBT
WOYK160LAT
10
WSYA095DAAOYA30LBTL
95
WPYA100LA
Single phase
Three phase
022
An air conditioner that is people-friendly is also environment-friendly. Fujitsu General offers a broad lineup of products from large living rooms to bedrooms and children’s rooms. We make your room more comfortable with a wide range of air conditioner types from ceiling wall type with automatic filters and cleaning functions to wall mounted type that improve the air cleaning function. Of course these models feature highly efficient operation that conserves electricity.
Energy saving design to provide a comfortable indoor environment while being environment-friendly.
Ceiling Wall
Wall Mounted
Floor
Compact Cassette
Cassette
Floor/Ceiling Universal
Ceiling
Slim Duct
Compact Duct
Medium Static Pressure Duct
High Static Pressure Duct
024
026
038
040
044
048
052
056
058
060
064
Split type Air ConditionersThe Intelligent Choice in Comfort
025024
Ceiling Wall
Rotor plates are installed above and below electromagnets.
"Vertical airflow" provides powerful floor level heating
"Horizontal airflow" does not blow cool air directly at the occupants in the room
Comfortable heating area
(Our company comparison)Approx.2.5 times*
*Compared to our conventional model ASY13PSCCW
Air is blown directly downwardPower diffuser (full open)
Big flap
Increased heat exchange efficiency
Specifications
9th year of record achievements. Automatic filter cleaning air conditioner
For AWYZ14 / 18LB For AWYZ24LB
Blown out horizontallyPower diffuser
Big flap
Increased heat exchange efficiency
Cooling range
(Our company comparison)Approx.1.7 times*
AWYZ14LB AWYZ18LB AWYZ24LB
CLASSA
ALLDC
CLASSA
ALLDC
CLASSA
ALLDC
Automatic filter cleaner
Clean & energy saving technologyDirt and dust are bacteria-eliminated by photocatalytic filter
Drives away bacteria and refreshes the air by UV (ultraviolet rays) illumination
Energy saving by automatic filter cleaning function
Axial gap fan motor enables nonconventional high power and high efficiency
CAE (Computer aided engineering) analysis
Antibacterial dust boxRemoves dirt and dust by double brushes. Dust collection is approx. twice that in the past. (our company comparison) Maintenance: Only throwing into a trash bin once every 2 years
Features (Compared to conventional models)Compact size with 1.5 more power output Self-driven method increases rotating efficiency by 10%. Our electromagnetic field simulation technology enables low vibration and low noise.
This function allows an energy saving of more than 25% a year and maintains a smooth airflow by preventing the filters from being clogged with dust.
New air trunk, which provides a smooth airflow, and axial gap fan motor increase the max. airflow by 10% over that of conventional models.
•Entire filter is cleaned automatically in approx. 2 minutes. •Since the filter is cleaned automatically, energy saving capability is displayed without regard to the load on the air conditioner.•Energy saving CLASS A cleared with a margin to spare.•2 exhaustive bacteria eliminating and deodorizing countermeasures keep the air in the room clean.
Axial gap method
Thin copper wire reducedelectric resistance.
Area, which confronts magnetic attraction is very wide and generates high power.
Rotor plate
Rotor plateElectromagnet
a b c d ea
b
c
d
e
*1
*1
*2
*3
Computer-designed fan provides a larger airflow than conventional models
*1. Announced September 9, 2002. In room air conditioner for the home (Our company's investigation) *2. Displays double the effect of a conventional optical medium and retains its property for a long time to suck in and remove approx. 99.99% of cigarette odors and bacteria, etc. *3. Announced December 13, 2004. As fan motor for air conditioner (Our company's investigation)
Dimensions Models: (Unit : mm)AWYZ14LB / AWYZ18LB / AWYZ24LB
POWERFULPOWERFULPOWERFUL
300
298899
250
170
40
Capacity
EER - Energy ClassCOP - Energy Class Running CurrentMoisture Removal
Airflow Rate (High)
Noise (Indoor)
Net Dimension H x W x D
Piping Connections (Small / Large)
Max Height Difference
Operation RangeCoolingHeating
Drain Pipe Diameter (I.D./O.D.)Max Pipe Length (Pre-Charge)
Refrigerant
HeatingCooling/HeatingInput Power
Power SourceCooling
Cooling
Indoor / Outdoor
Cooling H/M/L/Q/SQCoolingNoise (Outdoor)
HeatingCooling/Heating
Indoor
Outdoor
°CDB
mm
m
kg(lbs)mm
kW
kg(lbs)
A
W/W
m3/h
I/h
dB(A)
mm
V/ Ø/Hz
kW
AWYZ14LB
AOYZ14LB
230/1/504.20(0.9~5.3)6.00(0.9~9.1)
1.02/1.354.12-A4.44-A4.5/5.9
2.146/43/35/29/24
46850/1910
250×899×29813.5(30)
578x790x30039(86)
6.35/12.7013.8/15.8 to 16.7 13.8/15.8 to 16.7 13.8/15.8 to 16.7
20(15)15
-10~43-15~24R410A
Model No.Indoor unit
Outdoor unit
AWYZ18LB
AOYZ18LB
230/1/505.20(0.9~5.9)6.70(0.9~9.7)
1.58/1.633.29-A4.11-A6.9/7.2
2.846/43/35/29/24
47850/1910
250x899x29813.5(30)
578×790×30039(86)
6.35/12.70
20(15)15
-10~43-15~24R410A
AWYZ24LB
AOYZ24LB
230/1/507.10(0.9~8.0)8.50(0.9~11.0)
2.21/2.243.21-A3.62-A
9.7/10.33.0
47/43/40/36/3253
880/3600250x899x298
14(31)830×900×330
62(137)6.35/15.88
30(15)20
-10~43-15~24R410A
027026
Wall Mounted
Thin & Slim design
Specifications
Thin & Slim Design with High COP & Powerful Heating
ASYG09LT ASYG12LT
Dimensions Models: (Unit : mm)ASYG09LT / ASYG12LT
Capacity
EER - Energy ClassCOP - Energy Class Running CurrentMoisture Removal
Airflow Rate (High)
Noise (Indoor)
Net Dimension H x W x D
Piping Connections (Small / Large)
Max Height Difference
Operation RangeCoolingHeating
Drain Pipe Diameter (I.D./O.D.)Max Pipe Length (Pre-Charge)
Refrigerant
HeatingCooling/HeatingInput Power
Power SourceCooling
Cooling
Indoor / Outdoor
Cooling H/M/L/QCoolingNoise (Outdoor)
HeatingCooling/Heating
Indoor
Outdoor
°CDB
mm
m
kg(lbs)mm
kW
kg(lbs)
A
W/W
m3/h
I/h
dB(A)
mm
V/ Ø/Hz
kW
ASYG09LT
AOYG09LT
230/1/502.5(0.9-3.5)3.2(0.9-5.4)0.505/0.660
4.95-A4.85-A2.6/3.3
1.342/36/32/21
50800/1,700
282×870×1859.5(21)
540×790×29033(73)
6.35/9.5213.8/15.8 to 16.7
20(15)15
-10~43-20~24R410A
Model No.Indoor unit
Outdoor unit
ASYG12LT
AOYG12LT
230/1/503.5(1.1-4.0)4.0(0.9-6.5)0.850/0.910
4.12-A4.40-A4.0/4.3
1.843/37/32/21
48850/2,050
282×870×1859.5(21)
620×790×29040(88)
6.35/9.5213.8/15.8 to 16.7
20(15)15
-10~43-20~24R410A
Thin and slim design is realized by high density multi-path heat exchanger and high efficiency wind blower.
Powerful heatingRated heating capacity is maintained up to an outdoor temperature lower than –7 °C. This new model can operate even at –20 °C low outdoor temperature.
Powerful operation mode20 minutes continuous operation by maximum airflow and maximum compressor speed is possible. Rapid cooling and heating makes the room comfortable quickly.
Low noise mode for outdoor unitLow noise mode of outdoor unit can be selected by wireless remote controller.
Human sensor catches movements of people in a room, and operates with lower capacity when people leave the room. When people come back to the room, it automatically returns to previous operating mode.
Ø5mm
20mm -25 1050-5-10-15-20
1.0
2.0
3.0
4.0 New model
Current model
-25 1050-5-7-7 -10-15-20
1.0
2.0
3.0
4.0 New model
Current model
2.5kW class 3.5kW class
Hea
ting
Cap
acity
(kW
)
Hea
ting
Cap
acity
(kW
)
Outdoor Temperature (°C) Outdoor Temperature (°C)
Energy saving control
Weekly timer can be easily set by wireless remote controller.ON, OFF can be set up to 4 times in 1 day and up to 28 times in 1 week.For other modes, program timer and sleep timer can be also selected by one push.
3 Mode timer(Weekly/Program/Sleep)
Optional partsWired Remote Controller:Simple Remote Controller:Communication Kit:External Connect Kit:
UTY-RNNYMUTY-RSNYMUTY-TWBXFUTY-XWZXZ5
Wireless R.C. For ASYG09LT For ASYG12LT
Energy saving operation by detecting someone’s movement
282
870 185
337
55
Openpanel
Distributor 4-path
Refrigerant
Humansensor
Low ambient operation5040302010
0-10
-20°C
Cooling
24°C43°C
-10°C
Noise
Ratednoise level
100
or m
ore
Low noisePOWERFULPOWERFULPOWERFUL
Large intake 10°C
20°C
“10°C HEAT”Button ON
Indoor unitoperation START
Caution•When the room temperature is higher than 10°C, “10°C HEAT” operation does not start. Operation starts and maintains the room temperature at 10°C when the temperature drops below 10°C.
•When “10°C HEAT” operation stops, the room set temperature quickly returns to the preset temperature.
10°C HEAT Operation
The room temperature can be set to go no lower than 10°C, thus ensuring that the room does not get too cold when not occupied
*Only available with Wireless RC.
Heating
Slimness 185 mm
3dBDown
Low noisemode
Large fan
CLASSA
ALLDC
CLASSA
ALLDC
Human sensor catches movements of people in a room, and operates with lower capacitywhen people leave the room. When people come back to the room, it automatically returns toprevious operating mode.
Energy saving control
33333333 MMMMoMoMoMoModdddedededede ttttttt tiiimimimimimerererer
Energy saving operation by detecting someone’s movement
Humanansensorr
101010°C°C°C HH HEAEAEATTT OOOpOpperere tattatatatiiioioioionnnn *OnlOnly avy availaailableble withwith WirWireleseless RCs RC
029028
Wall Mounted
Thin & Slim design
Specifications
ASYG07LU ASYG09LU ASYG12LU ASYG14LU
Dimensions Models: (Unit : mm)ASYG07LU / ASYG09LU / ASYG12LU / ASYG14LU
Capacity
EER - Energy ClassCOP - Energy Class Running CurrentMoisture Removal
Airflow Rate (High)
Noise (Indoor)
Net Dimension H x W x D
Piping Connections (Small / Large)
Max Height Difference
Operation RangeCoolingHeating
Drain Pipe Diameter (I.D./O.D.)Max Pipe Length (Pre-Charge)
Refrigerant
HeatingCooling/HeatingInput Power
Power SourceCooling
Cooling
Indoor / Outdoor
Cooling H/M/L/QCoolingNoise (Outdoor)
HeatingCooling/Heating
Indoor
Outdoor
°CDB
mm
m
kg(lbs)mm
kW
kg(lbs)
A
W/W
m3/h
I/h
dB(A)
mm
V/ Ø/Hz
kW
ASYG07LU
AOYG07LU
230/1/502.0(0.5~3.0)3.0(0.5~4.0)0.460/0.660
4.35-A4.55-A2.6/3.4
1.038/35/31/21
46680/1,720
282×870×1859.5(21)
540×660×29023(51)
6.35/9.5213.8/15.8 to 16.7
20(15)15
-10~43-15~24R410A
Model No.Indoor unit
Outdoor unit
ASYG09LU
AOYG09LU
230/1/502.5(0.5~3.2)3.2(0.5~4.2)0.555/0.680
4.50-A4.71-A3.1/3.4
1.342/36/32/21
48800/1,720
282x870x1859.5(21)
540x660x29025(55)
6.35/9.5213.8/15.8 to 16.7
20(15)15
-10~43-15~24R410A
ASYG12LU
AOYG12LU
230/1/503.5(0.9~4.0)4.0(0.9~5.6)0.905/0.930
3.87-A4.30-A4.6/4.7
1.843/37/32/21
50850/1,940
282x870x1859.5(21)
540x790x29033(73)
6.35/9.5213.8/15.8 to 16.7
20(15)15
-10~43-15~24R410A
ASYG14LU
AOYG14LU
230/1/504.2(0.9~5.0)5.4(0.9~6.0)1.235/1.380
3.40-A3.91-A5.8/6.3
2.145/40/33/25
50900/1,940
282x870x1859.5(21)
540x790x29034(75)
6.35/12.713.8/15.8 to 16.7
20(15)15
-10~43-15~24R410A
Thin and slim design is realized by Ø5mm heat exchanger and high efficiency wind blower. Big open panel and High density multi path heat exchanger
Ø5mm
20mm
Weekly timer can be easily set by wireless remote controller.ON, OFF can be set up to 4 times in 1 day and up to 28 times in 1 week.For other modes, program timer and sleep timer can be also selected by one push.
Indicates the filter cleaning period by lamp.
3 Mode timer(Weekly/Program/Sleep)
Filter sign display
Optional partsWired Remote Controller:Simple Remote Controller:Communication Kit:External Connect Kit:
UTY-RNNYMUTY-RSNYMUTY-TWBXFUTY-XWZXZ5
Wireless R.C. For ASYG07/09LU For ASYG12/14LU
H282 X W870 X D185
10°C
20°C
“10°C HEAT”Button ON
Indoor unitoperation START
Caution•When the room temperature is higher than 10°C, “10°C HEAT” operation does not start. Operation starts and maintains the room temperature at 10°C when the temperature drops below 10°C.
•When “10°C HEAT” operation stops, the room set temperature quickly returns to the preset temperature.
10°C HEAT OperationThe room temperature can be set to go no lower than 10°C, thus ensuring that the room does not get too cold when not occupied
*Only available with Wireless RC.
Large fan
Open panel
Low ambient operation
5040302010
0-10
-15°C
Cooling
24°CHeating
43°C
-10°C
282
870 185
337
55
100
or m
ore
Distributor 4-path
RefrigerantLarge intake
Low noisePOWERFULPOWERFULPOWERFUL
Powerful operation20 minutes continuous operation by maximum airflow and maximum compressor speed is possible. Rapid cooling and heating makes the room comfortable quickly.
Low noise mode for outdoor unitLow noise mode of outdoor unit can be selected by wireless remote controller.
Noise
Ratednoise level
3dBDown
Low noisemode
185mm
Powerful
Setting temp.
Normal mode
Time
Tem
pera
ture
CLASSA
ALLDC
CLASSA
ALLDC
CLASSA
ALLDC
CLASSA
ALLDC
031030
Wall Mounted
Compact design
Specifications Dimensions Models: (Unit : mm)ASYG07LE / ASYG09LE / ASYG12LE / ASYG14LE
High density heat exchanger arrangement
ASYG14LE
CLASSA
ALLDC
Wireless R.C.
Powerful operation
Indicates the filter cleaning period by lamp.
Filter sign display
Quiet operation
ASYG07LE ASYG09LE ASYG12LE
CLASSA
ALLDC
CLASSA
ALLDC
CLASSA
ALLDC
Simple design with energy saving.
For ASYG07/09/12LE
For ASYG14LE
Volume reduction of heat
exchanger: 30%
Making the tube thin:
7mm 5mm
Even temperature
Improved the heatexchanger effectiveness
660
For AOYG07/09/12LEFor ASYG07/09/12LE
Indoor unit Outdoor unit
Cooling mode (07/09/12 TYPE)
QuietFan speed
21dB(A)
Noise level
10°C
20°C
“10°C HEAT”Button ON
Indoor unitoperation START
20 minutes continuous operation by maximum airflow and maximum compressor speed is possible. Rapid cooling and heating makes the room comfortable quickly.
Easy maintenance
Removable & washable panel
Caution•When the room temperature is higher than 10°C, “10°C HEAT” operation does not start. Operation starts and maintains the room temperature at 10°C when the temperature drops below 10°C.
•When “10°C HEAT” operation stops, the room set temperature quickly returns to the preset temperature.
Low noise mode for outdoor unitLow noise mode of outdoor unit can be selected by wireless remote controller.
Noise
Ratednoise level
3dBDown
Low noisemode
10°C HEAT Operation
The room temperature can be set to go no lower than 10°C, thus ensuring that the room does not get too cold when not occupied
Capacity
EER - Energy ClassCOP - Energy Class Running CurrentMoisture Removal
Airflow Rate (High)
Noise (Indoor)
Net Dimension H x W x D
Piping Connections (Small / Large)
Max Height Difference
Operation RangeCoolingHeating
Drain Pipe Diameter (I.D./O.D.)Max Pipe Length (Pre-Charge)
Refrigerant
HeatingCooling/HeatingInput Power
Power SourceCooling
Cooling
Indoor / Outdoor
Cooling H/M/L/QCoolingNoise (Outdoor)
HeatingCooling/Heating
Indoor
Outdoor
°CDB
mm
m
kg(lbs)mm
kW
kg(lbs)
A
W/W
m3/h
I/h
dB(A)
mm
V/ Ø/Hz
kW
ASYG07LE
AOYG07LE
230/1/500.5-3.00.5-4.0
0.47/0.6854.47-A4.38-A2.7/3.5
1.043/38/31/21
45690/1720
260X790X1987.5(17)
540X660X29023(51)
6.35/9.5213.8/15.8 to 16.7
20(15)15
-10~43-15~24R410A
ASYG09LE
AOYG09LE
230/1/500.5-3.20.5-4.2
0.64/0.753.91-A4.27-A3.5/3.8
1.343/38/31/21
45690/1720
260X790X1987.5(17)
540X660X29023(51)
6.35/9.5213.8/15.8 to 16.7
20(15)15
-10~43-15~24R410A
Model No.Indoor unit
Outdoor unit
ASYG12LE
AOYG12LE
230/1/500.9-3.90.9-5.3
0.92/0.993.70-A4.04-A4.4/4.7
1.843/38/31/21
50690/1830
260X790X1987.5(17)
540X660X29029(64)
6.35/9.5213.8/15.8 to 16.7
20(15)15
-10~43-15~24R410A
ASYG14LE
AOYG14LE
230/1/500.9-5.00.9-6.4
1.105/1.3053.62-A3.83-A5.3/6.0
2.144/40/33/25
49770/1,800
280X790X2038.0(18)
540X790X29034(75)
6.35/12.713.8/15.8 to 16.7
20(15)15
-10~43-15~24R410A
Low ambient operation50
40
30
20
10
0
-10
43°C
-15°C
Cooling
24°CHeating
-10°C
Optional partsWired Remote Controller:Simple Remote Controller:Communication Kit:
External Connect Kit:
UTY-RNNYMUTY-RSNYMUTY-XCBXE (07/09/12 Type)
UTY-XCBXZ1 (14 Type)
UTY-XWZX
*Only available with Wireless RC.
ASYG07/09/12LE ASYG14LE
Low noisePOWERFULPOWERFULPOWERFUL
260
198
Powerful
Setting temp.
Normal mode
Time
Tem
pera
ture
198790
260
203790
280
033032
Wall Mounted
Power Source
Capacity
Input PowerEER - Energy ClassCOP - Energy ClassRunning CurrentMoisture RemovalNoise (Indoor)Noise (Outdoor)Airflow Rate (High)
Piping Connections (Small / Large)Drain Pipe Diameter (I.D./O.D.)Max Pipe Length (Pre-Charge)Height Difference
Refrigerant
Net Dimension H x W x D
OperationRange
CoolingHeating
Cooling/HeatingCoolingHeating
Cooling/Heating
CoolingHeating
CoolingIndoor/Outdoor
Indoor
Outdoor
Cooling H/M/L/Q
m
°CDB
kg(lbs)mm
kg(lbs)mmmm
mm
dB(A)
kW
kW
W/W
AI/h
m3/h
V/Ø/Hz
ASYG18LF
AOYG18LF
230/1/505.20(0.9~6.0)6.30(0.9~9.1)
1.52/1.713.42-A3.68-A6.8/7.6
2.843/37/33/26
51900/2070
320X998X23814(30.8)
620X790X29840(88)
6.35/12.812/1625(15)
20-10~46-15~24R410A
ASYG24LF
AOYG24LF
230/1/507.10(0.9~8.0)
8.00(0.9~10.6)2.20/2.21
3.23-A3.61-A9.7/9.8
2.747/42/37/32
521100/2340
320X998X23814(30.8)
578X790X31543(95)
6.35/15.8812/1630(15)
20-10~46-15~24R410A
ASYG30LF
AOYG30LF
230/1/508.00(2.9~9.0)8.80(2.2~11.0)
2.49/2.443.21-A3.61-A
10.9/10.73.2
48/42/37/3353
1100/3600320X998X238
14(30.8)830X900X330
61(135)9.52/15.88
12/1650(20)
30-10~46-15~24R410A
Indoor unit
Outdoor unitModel No.
Specifications
Simple & Elegant Appearance Design
ASYG18LF ASYG24LF ASYG30LF
CLASSA
ALLDC
CLASSA
ALLDC
CLASSA
ALLDC
Dimensions Models: (Unit : mm)ASYG18LF / ASYG24LF / ASYG30LF
(18/30)(24)
For ASYG24LFFor ASYG18LF For ASYG30LF
Wireless R.C.
“Vertical airflow” provides powerful floor level heating
Power diffuser
Power diffuser (full open)
46o
(˚C)
15 16 17 18
Outside air conditions: 35˚C 40% Operation contents: Cooling, Set temperature (Min set temp) 18˚C, airflow Hi, Air direction downward and front
(24/30)
Outside air conditions: 2˚C 60% Operation contents: Heating, Set temperature (Max set temp) 30˚C, airflow Hi, Air direction downward and front
33 32 31 30 29
(˚C)
(24/30)
Ion Deodorization Filter
Apple-catechin Filter
Pre Filter
Organic coating fin used heat exchanger
Antibacterial deodorizing pre-filter with special ceramic powder
Air conditioner filter features
Long-life* Ion Deodorization Filter
Apple-catechin Filter
Using different filters at both sides
The filter deodorizes by powerfully decomposing absorbed odors using the oxidizing and reducing effects of ions generated by the ultra-fine-particle ceramic.
Fine dust, invisible mold spores, and harmful microorganisms are absorbed onto the filter by static electricity, and further growth is inhibited and deactivated by the polyphenol extracted from apples.
(*The filter can be used for approx. 3 years if it is washed under water to restore its surface action when it is dirty.)
Low ambient operation
Optional parts
Wired Remote Controller: UTY-RNNYMSimple Remote Controller: UTY-RSNYMExternal Connect Kit: UTY-XWZX
Flexible Installation
20m
25m18 type
30m
50m30 type
20m
30m24 type
Max. Height
Max. Piping Length
Easy maintenance
Simplification of drain pan cleaning improves maintenance-ability.
50
40
30
20
10
0
-10
46°C
-15°C
Cooling
24°CHeating
-10°C
“Horizontal airflow” does not blow cool air directly at the occupants in the room
998
238
320
520
520
590
721
25
ø 32
ø 16
ø 12
Refrigerant pipe flare connection (Liquid)Refrigerant pipe flare connection (Gas)Drain hose connection (Drain hose)
21
3
035034
Wall Mounted
Handy type remote controller
Specifications Dimensions Models: (Unit : mm)ASY7UB / ASY9UC / ASY12UC
ASY7UB ASY9UC ASY12UC
For ASY7UB/9UC For ASY12UC
Easy maintenance
Easy maintenance has been realized as the front panel can be removed for easy access.
Symmetrical design
Compact design
Symmetrical, clean design that suits all interiors.
Auto swing louver
6-step air directions by auto swing louver.
Steps
Swing
Remote Control Unit Display(LCD)
Signal Transmitter
Fan Control Button
Vertical Set Button
Vertical Swing ButtonAcl Button
Set Temp. Button
Master Control Button
Coil Dry Button*
Test Run Button
*This function is only for ASY9UC/12UCTimer Button
Sleep Button
Start/Stop Button
-step6
187808
257
Capacity
EER - Energy ClassCOP - Energy Class Running CurrentMoisture Removal
Airflow Rate (High)
Noise (Indoor)
Net Dimension H x W x D
Piping Connections (Small / Large)
Max Height Difference
Operation RangeCoolingHeating
Drain Pipe Diameter (I.D./O.D.)Max Pipe Length (Pre-Charge)
Refrigerant
HeatingCooling/HeatingInput Power
Power SourceCooling
Cooling
Indoor / Outdoor
Cooling H/M/L/QCoolingNoise (Outdoor)
HeatingCooling/Heating
Indoor
Outdoor
°C
mm
m
kg(lbs)mm
kW
kg(lbs)
A
W/W
m3/h
I/h
dB(A)
mm
V/ Ø/Hz
kW
ASY7UB
AOY7UB
230/1/502.202.30
0.83/0.752.65-D3.07-D3.9/3.6
1.038/35/33/29
43380/1350
257x808x1878(18)
535x650x25026(57)
6.35/9.5212.0/16.2 to 17.0
10(7.5)5
21~43-15~24R410A
ASY9UC
AOY9UC
230/1/502.602.95
1.07/0.902.43-E3.28-C4.8/4.1
1.340/38/35/30
46540/1350
257x808x1878(18)
535x650x25028(62)
6.35/9.5212.0/16.2 to 17.0
15(7.5)8
21~43-15~24R410A
ASY12UC
AOY12UC
230/1/503.253.95
1.35/1.282.41-E3.09-D5.9/5.6
1.840/38/36/33
48540/1700
257x808x1878(18)
535x695x25031(68)
6.35/9.5212.0/16.2 to 17.0
15(7.5)8
21~43-15~24R410A
Model No.Indoor unit
Outdoor unit
25.7cm
80.8cm
18.7cm
037036
Wall Mounted
Specifications
ASY18UB ASY24UB ASY30UB
Dimensions Models: (Unit : mm)ASY18UB / ASY24UB / ASY30UB
Power Source
Capacity
Input PowerEER - Energy ClassCOP - Energy ClassRunning CurrentMoisture RemovalNoise (Indoor)Noise (Outdoor)Airflow Rate (High)
Piping Connections (Small / Large)Drain Pipe Diameter (I.D./O.D.)Max Pipe Length (Pre-Charge)Height Difference
Refrigerant
Net Dimension H x W x D
OperationRange
CoolingHeating
Cooling/HeatingCoolingHeating
Cooling/Heating
CoolingHeating
CoolingIndoor/Outdoor
Indoor
Outdoor
Cooling H/M/L
m
°CDB
kg(lbs)mm
kg(lbs)mmmm
mm
dB(A)
kW
kW
W/W
AI/h
m3/h
V/Ø/Hz
ASY18UB
AOY18UB
230/1/505.40 5.70
1.85/1.852.92-C3.08-D8.3/8.3
2.0 41/37.5/34
52800/3200
320x1120x220
16(35)650x830x320
52(114)6.35/15.88
12.0/16.2 to 17.020(7.5)
80~43-6~24R410A
ASY24UB
AOY24UB
230/1/506.807.40
2.40/2.402.83-C3.08-D
10.6/10.52.5
45/42/3853
970/3200
320x1120x220
16(35)650x830x320
59(130)9.52/15.88
12.0/16.2 to 17.020(7.5)
80~43-6~24R410A
ASY30UB
AOY30UB
230/1/507.908.40
2.75/2.752.87-C3.05-D
13.0/13.03.0
47.5/44/40.554
1040/3320
320x1120x220
16(35)900X900X350
74(163)9.52/15.88
12.0/16.2 to 17.025(7.5)
150~43-6~24R410A
Indoor unit
Outdoor unitModel No.
For ASY18/24UB For ASY30UB
Powerful output in spite of small size
Though the indoor unit is compact, it features a large, high pressure cross fan (107mm diameter) in a center mounted configuration and a lambda type heat exchanger to provide plenty of power. The extra long diffuser provides a wide outflow opening for air. This ensures a large air outflow volume over a wide area to cool or heat all areas of the room.
Low noise
Multi airflow
Large independently driven power diffuser used
Expanded work space at bottom of casing increases piping space by 15%.
Increases piping space by 15%
•High efficiency fan construction ø7mm Lambda type evaporator improves the airflow path•Large independently driven power diffuser
ø7 lambda type evaporator
Large independently driven power diffuser
Others
Cooling Heating
Steps
SwingSteps
Swing43
2
1
432
1
Horizontal concentration and other air direction control
Wide down flow
•Double auto swing •2-way draining route
Power diffuser
Power diffuser
Easy installation
Low noise
34dB
(ASY18)
Large independently driven power diffuser
Refrigerant piping flare connection (Gas)Refrigerant piping flare connection (Liquid)Drain piping connection
21
3
3
21
1,120
220
593
691
721
320
039038
Floor
Power Source
Capacity
Input PowerEER - Energy ClassCOP - Energy ClassRunning CurrentMoisture RemovalNoise (Indoor)Noise (Outdoor)Airflow Rate (High)
Piping Connections (Small / Large)Drain Pipe Diameter (I.D./O.D.)Max Pipe Length (Pre-Charge)Height Difference
Refrigerant
Net Dimension H x W x D
OperationRange
CoolingHeating
Cooling/HeatingCoolingHeating
Cooling/Heating
CoolingHeating
CoolingIndoor/Outdoor
Indoor
Outdoor
Cooling H/M/L/Q
m
°CDB
kg(lbs)mm
kg(lbs)mmmm
mm
dB(A)
kW
kW
W/W
AI/h
m3/h
V/Ø/Hz
AGYF09LA
AOYV09LA
230/1/502.60(0.9~3.5)3.50(0.9~5.5)
0.53/0.794.91-A4.43-A2.6/3.8
1.3 40/35/29/22
47570/1680
600x740x200
14(31)540x790x290
36(79)6.35/9.52
13.8/15.8 to 16.720(15)
15 -10~43-15~24R410A
AGYF12LA
AOYV12LA
230/1/503.50(0.9~4.0)4.50(0.9~6.6)
0.94/1.193.72-A3.78-A4.4/5.5
1.8 40/35/29/22
48570/1680
600x740x200
14(31)540x790x290
36(79)6.35/9.52
13.8/15.8 to16.720(15)
15-10~43-15~24R410A
AGYF14LA
AOYV14LA
230/1/504.20(0.9~5.0)5.20(0.9~8.0)
1.14/1.443.68-A3.61-A5.2/6.4
2.1 44/38/31/22
50650/1910
600x740x200
14(31)578x790x300
40(88)6.35/12.7
13.8/15.8 to 16.720(15)
15-10~43-15~24R410A
Indoor unit
Outdoor unitModel No.
Specifications Dimensions Models: (Unit : mm)AGYF09LA / AGYF12LA / AGYF14LA
Flexible & easy installation
AGYF09LA AGYF12LA AGYF14LA
CLASSA
ALLDC
CLASSA
ALLDC
CLASSA
ALLDC
Simple & Thin design harmonizes with the interior
For AGYF09/12LA For AGYF14LA
Cooling
at operationstart
at operationstart
Heating WindowPrevents cold draft from window
at stableoperation
Prevents cold air from falling
at stableoperation
Beneathstandard window
Standard concaveportion Wall Half concealed
(Optional parts necessary)
(unit:mm)
600
740200
700
(unit:mm)
Min.700
Min. 590
Min.940
(unit:mm) (unit:mm)Max. 150
Min. 730 Max. 80
2-Fan & Wide airflow
Flexible piping connection6 direction of drain & piping
Back view
Drain hosePiping
1 62 53 4
Filter features
Long-life* Ion Deodorization Filter
Apple-catechin Filter
Using different filters at both sides
The filter deodorizes by powerfully decomposing absorbed odors using the oxidizing and reducing effects of ions generated by the ultra-fine-particle ceramic.
Fine dust, invisible mold spores, and harmful microorganisms are absorbed onto the filter by static electricity, and further growth is inhibited and deactivated by the polyphenol extracted from apples.
(*The filter can be used for approx. 3 years if it is washed under water to restore its surface action when it is dirty.)
Apple-catechin Filter
Ion Deodorization Filter
10°C HEAT Operation
The room temperature can be set to go no lower than 10°C, thus ensuring that the room does not get too cold when not occupied
10°C
20°C
“10°C HEAT”Button ON
Indoor unitoperation START
•When the room temperature is higher than 10°C, “10°C HEAT” operation does not start. Operation starts and maintains the room temperature at 10°C when the temperature drops below 10°C.
•When “10°C HEAT” operation stops, the room set temperature quickly returns to the preset temperature.
“10°C HEAT”Button ON
Quiet operation
Industry leading noise levels
Low ambient operation
Easy maintenance
Washable panel removableRemovable panel
Optional parts
Wired Remote Controller: UTY-RNNYMHalf Concealed Kit: UTR-STAExternal Connect Kit: UTY-XWZX
50
40
30
20
10
0
-10
43°C
-15°C
Cooling
24°CHeating
-10°C
Low level
22dB(A)
Fan speed
Quiet
200
600
740
Front view
Side view
Caution
041040
Compact Cassette
Specifications Dimensions Models: (Unit : mm)AUYG12LVLB / AUYG14LVLB / AUYG18LVLB / AUYF24LB
AUYG12LVLB AUYG14LVLB AUYG18LVLB
CLASSA
ALLDC
CLASSA
ALLDC
CLASSA
ALLDC
AUYF24LB
CLASSA
ALLDC
Powerful wide air flow & Quiet operation
Low ambient operation
Grille is an option
Compact Outdoor Unit
Wireless R.C.
Adoption of laminar wing
Spin direction Airflow direction
Quiet
Airflow runs through smoothly along the laminar wing
No airflow separation
Laminar wingQuiet
2-stage turbo fanHigh efficiency design by 2 stage structure
Quiet quality
Previous turbo fan 2-stage turbo fan
1-stage
+2-stage2 stage
Fast
Slow
Windvelocity In the case of a conventional
fan, the air outlet range was narrow as the airflow moved to the motor side which meant the velocity of air passing through the heat exchanger was uneven.
Designed by CFD-analysis (fluid) simulations
Optimization of wing form (laminar wing type) and wing number (7 blades each)
ABCD
Grille cover2
1
3: standard equipment
During installation, maintenance and operation, the drain pump and kit can be checked easily.
Maintenance of the fan motor and fan can be done easily after taking off the panel as the bell mouth of the fan can be removed easily.
A : Fan motorC : Bell-mouth
B : 2-stage turbo fanD : Panel
Easy maintenance
1 Maintenance of fan motor and fan
2 Long life filter
3 Adaptation of transparent drainage parts
Previous model New model
24 type
Compact designWorlds first 24,000Btu model in the compact cassette category (Easy installation by taking off ceiling panel of 600 x 600 size)
570570 570570570 570
590 590
24 type
830830
High lift drain pump
700mm
Heat exchangeefficiency:
20%UP
700
30 4970
0
530(Bolt pitch)
540(
Bol
t pitc
h)
570(
Indo
or u
nit)
580-
660(
Cei
ling
open
ings
)
75
114
215 26
230
5830 123
135 250
Control box Liquid pipe Gas pipeCeiling
Side view
Top view
Side view
Bottom view
30
9940
102
102
108
146
245
50
40
30
20
10
0
-10
-15°C
Cooling
24°CHeating
-10°C
Power Source
Capacity
Input PowerEER - Energy ClassCOP - Energy ClassRunning CurrentMoisture RemovalNoise (Indoor)Noise (Outdoor)Airflow Rate (High)
Piping Connections (Small / Large)Drain Pipe Diameter (I.D./O.D.)Max Pipe Length (Pre-Charge)Height Difference
RefrigerantDecoration Panel
Net Dimension H x W x D
OperationRange
CoolingHeating
Cooling/HeatingCoolingHeating
Cooling/Heating
CoolingHeating
CoolingIndoor/Outdoor
Indoor / Grille
Outdoor
Cooling H/M/L/Q
m
°CDB
kg(lbs)mm
kg(lbs)mmmm
mm
dB(A)
kW
kW
W/W
AI/h
m3/h
V/Ø/Hz
AUYG12LVLB
AOYG12LA
230/1/503.504.10
1.05/1.113.33-A3.69-A4.8/5.1
1.2 37/34/30/27
47600/1780
245×570×570/49x700x70015(33)/2.6(6)578×790×300
40(88)6.35/9.52
25/3225(15)
15-10~46-15~24R410A
UTG-UFYD-W
AUYG14LVLB
AOYG14LA
230/1/504.305.00
1.33/1.343.21-A3.71-A6.1/6.1
1.5 38/34/30/27
49680/1910
245×570×570/49x700x70015(33)/2.6(6)578×790×300
40(88)6.35/12.70
25/3225(15)
15-10~46-15~24R410A
UTG-UFYD-W
AUYG18LVLB
AOYG18LA
230/1/505.206.00
1.62/1.663.21-A3.61-A7.2/7.4
2.2 38/34/30/26
50680/2000
245×570×570/49x700x70015(33)/2.6(6)578x790x300
40(88)6.35/12.70
25/3225(15)
15 -10~46-15~24R410A
UTG-UFYD-W
AUYF24LB
AOYA24LA
230/1/507.108.00
2.21/2.213.21-A3.61-A9.7/9.7
2.7 49/44/36/30
52930/2470
245×570×570/49x700x70017(37)/2.6(6)578x790x315
44(97)6.35/15.8819.4/26.8
30(15)20
-10~46-15~24R410A
UTG-UFYB-W
Model No.Indoor unit
Outdoor unit
46°C
Optional partsAir Outlet Shutter Plate:Wired Remote Controller:Insulation Kit For High Humidity:External Connect Kit:External Control Set:Fresh Air Intake Kit:Simple Remote Controller:
UTR-YDZBUTY-RNNYMUTZ-KXGCUTY-XWZXUTD-ECS5AUTZ-VXAAUTY-RSNYM
A evenly spread air distribution across the heat exchanger is possible due to the new 2 stage turbo fan which produces two separate airflow streams.
(12/14/18)
043042
Compact Cassette
Specifications Dimensions Models: (Unit : mm)AUY18UB
AUY18UB
Optional parts
Additional Grille: UTG-AGDA-W
Compact grille fits European ceiling panel(650 x 650 mm)
Compact size
Wireless R.C.
Auto air flow direction and auto swing
Comfortable air flow
4-way
3-way2-way
Select 2-way, 3-way or 4-way air flow to suit your needs.
43
2
1
1
2
3
4
4 step swing 2-4 way air flow system
StepsAuto swing
235400
580Condensate pump lift to 400mm
Punch Hall grille
650
650
(unit: mm)
Fresh air can be introduced through this opening
Conditioned air can be distributed by means of a distribution duct1-way 2-way
Duct connection hole opening
Distribution duct
Distribution duct
Fresh air
Additional grille (optional parts)
770mm
770mm
Additional grille The ceiling hole
Indoor Unit (grille)650mm
650m
m
Power Source
Capacity
Input PowerEER - Energy ClassCOP - Energy ClassRunning CurrentMoisture RemovalNoise (Indoor)Noise (Outdoor)Airflow Rate (High)
Piping Connections (Small / Large)Max Pipe Length (Pre-Charge)Height Difference
RefrigerantDecoration Panel
Net Dimension H x W x D
OperationRange
CoolingHeating
Cooling/HeatingCoolingHeating
Cooling/Heating
CoolingHeating
CoolingIndoor/Outdoor
Indoor / Grille
Outdoor
Cooling H/M/L
m
°CDB
kg(lbs)mm
kg(lbs)mm
mm
dB(A)
kW
kW
W/W
AI/h
m3/h
V/Ø/Hz
AUY18UB
AOY18UB
230/1/504.855.40
1.85/2.002.62-D2.70-E8.2/9.2
2.1 44/41/37
52620/3200
235x580x580
18(40)650x830x320
52(115)6.35/12.70
20(10)8
0~43-7~24R410A
UTG-UDYD-W
Model No.Indoor unit
Outdoor unit
20 35
66
235
650
245
580
650580
440
(Han
ging
bol
t pos
ition
)
6
06
(Hanging bolt position) 400
(Grille measurement) 650
440
131
245
54
111 47
66
46
60
86
Drain pipe(I.D 32).
600(Ceiling opening measurement)
Side view
Top view
Bottom viewBottom view (Panel)
045044
Cassette
High efficiency turbo fan with 3-dimensional blade
Specifications Dimensions Models: (Unit : mm)AUYA30LB / AUYA36LB / AUYA45LC / AUYA54LC AUYG36LR /AUYG45LR / AUYG54LR
Detachable Grille corner
Adjustment can be done just taking off the corner part
450mm 500mm
WindvelocityHeat exchanger
< Motor side >
Uneven airflow
Fast
SlowConventional blade
Separation phenomenon of airflow causes noise
: Spin direction : Airflow direction : Turbulent flow noise
< Motor side >Heat exchanger
3-dimensional blade
No airflow separation
Previous turbo fan: Air passing through the heat exchanger was uneven and the air would only flow close to the ceiling.
New turbo fan: High efficiency airflow distribution has been achieved by the introduction of a 3 dimensional blade which increases the air passing over the heat exchanger.
Quiet
High lift drain pump
Optional partsWired Remote Controller:IR Receiver Kit:Wide Panel:Panel Spacer:Air Outlet Shutter Plate:Insulation Kit For High Humidity:External Connect Kit:
External Control Set:Fresh Air Intake Kit:
UTY-RNNYMUTY-LRHYA1UTG-AGYA-WUTG-BGYA-WUTR-YDZCUTZ-KXGAUTY-XWZXUTY-XWZXZ2UTY-XWZXZ3UTD-ECS5AUTZ-VXGA
Ceiling panel
850mm
Powerful wide air flow & Quiet operation
For AUYA30/36LB
Low ambient operation
Wired R.C.Grille is an option
Improvement of the airflow distribution
Adjustment of hanger position is possible after installation
New louvre: The louvre design distributes air leaving a space between the chassis and the ceiling allowing far and wide air flow distribution.
Much less temperature irregularity happens by spreading airflow widely
Bottom view
Front part Ceiling
Rear part
Round louvre
358
9813
3
118
158
288
Drain pipe
Liquid pipe
Side view
Top view
Gas pipe
338278
950
950Bottom view
890
(Cei
ling
open
ings
)
699
(Bol
t pitc
h)
796 (Bolt pitch)
842 (indoor unit)
AUYA30LB AUYA36LBAUYG36LR
CLASSA
ALLDC
CLASSA
ALLDC
AUYA45LCAUYG45LR
CLASSA
ALLDC
AUYA54LCAUYG54LR
CLASSA
ALLDC
For AUYG36/45/54LR(For 3 phase)
For AUYA45/54LC(For single phase)
50
40
30
20
10
0
-10
-15°C
Cooling
24°CHeating
46°C
-15°C
Singlephase
Capacity
EER - Energy ClassCOP - Energy Class Running CurrentMoisture Removal
Airflow Rate (High)
Noise (Indoor)
Net Dimension H x W x D
Piping Connections (Small / Large)
Height Difference
Operation RangeCoolingHeating
Drain Pipe Diameter (I.D./O.D.)Max Pipe Length (Pre-Charge)
RefrigerantDecoration Panel
HeatingCooling/HeatingInput Power
Power Source Cooling
Cooling
Indoor / Outdoor
Cooling H/M/L/QCoolingNoise (Outdoor)
HeatingCooling/Heating
Indoor /Grille
Outdoor
°CDB
mm
m
kg(lbs)mm
mm
kW
kg(lbs)
A
W/W
m3/h
I/h
dB(A)
mm
V/ Ø/Hz
kW
AUYA30LB
AOYA30LF
230/1/508.50
10.002.65/2.77
3.21-A3.61-A
11.6/12.22.5
40/38/36/3253
1600/3600288x840x84050x950x950
26(57)/5.5(12)830x900x330
61(135)9.52/15.8825.0/32.0
50(20)30
-15~46-15~24R410A
UTG-UGYA-W
Model No.Indoor unit
Outdoor unit
AUYG36LR
AOYG36LA
400/3/5010.0011.20
2.44/2.564.10-A4.38-A3.7/3.9
3.044/39/36/33
511800/6200
288x840x84050x950x950
27(60)/5.5(12)1290×900×330
105(229)9.52/15.8825.0/32.0
75(30)30
-15~46-15~24R410A
UTG-UGYA-W
AUYA45LC
AOYA45LC
230/1/5012.5014.00
3.90/3.773.21-A3.71-A
17.0/16.54.5
46/42/40/3655
1900/6750288x840x84050x950x950
27(60)/5.5(12)1290×900×330
88(194)9.52/15.8825.0/32.0
50(20)30
-15~46-15~24R410A
UTG-UGYA-W
AUYG45LR
AOYG45LA
400/3/5012.5014.00
3.54/3.583.53-A3.91-A5.3/5.3
4.546/42/40/36
541900/6900
288x840x84050x950x950
27(60)/5.5(12)1290×900×330
105(229)9.52/15.8825.0/32.0
75(30)30
-15~46-15~24R410A
UTG-UGYA-W
AUYG54LR
AOYG54LA
400/3/5014.0016.00
4.36/4.433.21-A3.61-A6.5/6.6
5.047/43/41/37
552000/6900
288x840x84050x950x950
27(60)/5.5(12)1290×900×330
105(229)9.52/15.8825.0/32.0
75(30)30
-15~46-15~24R410A
UTG-UGYA-W
AUYA54LC
AOYA54LC
230/1/5013.316.0
4.42/4.693.01-B3.41-B
19.3/20.55.0
47/43/41/3755
2000/6750288x840x84050x950x950
27(60)/5.5(12)1290×900×330
88(194)9.52/15.8825.0/32.0
50(20)30
-15~46-15~24R410A
UTG-UGYA-W
AUYA36LB
AOYA36LF
230/1/5010.0011.20
3.12/3.023.21-A3.71-A
13.7/13.33.5
43/38/36/3254
1800/3800288x840x84050x950x950
26(57)/5.5(12)830x900x330
61(135)9.52/15.8825.0/32.0
50(20)30
-15~46-15~24R410A
UTG-UGYA-W
Low noise mode of outdoor unit (45/54 types)
2 stage low noise mode can be selected.(Option)
Roted noise value
Mode 1
Mode 2
Lownoisemode
-4dB-2dB
3phase 3phase 3phase
047046
Cassette
Specifications DimensionsModels:
(Unit : mm)
AUY25UU / AUY30UU Models: AUY36UU / AUY45UU / AUY54UU
Auto air flow direction and auto swing
Comfortable airflow
4-way
3-way2-way
Select 2-way, 3-way or 4-way air flow to suit your needs.
4 step swing 2-4 way air flow system
Power Source
Capacity
Input PowerEER - Energy ClassCOP - Energy ClassRunning CurrentMoisture RemovalNoise (Indoor)Noise (Outdoor)Airflow Rate (High)
Piping Connections (Small / Large)Max Pipe Length (Pre-Charge)Height Difference
Refrigerant
Net Dimension H x W x D
OperationRange
CoolingHeating
Cooling/HeatingCoolingHeating
Cooling/Heating
CoolingHeating
CoolingIndoor/Outdoor
Indoor
Outdoor
Cooling H/M/L
m
°CDB
kg(lbs)mm
kg(lbs)mm
mm
dB(A)
kW
kW
W/W
AI/h
m3/h
V/Ø/Hz
AUY25UU
AOY25UU
230/1/507.007.80
2.65/2.352.64-D3.32-C
11.8/10.52.5
44/42/3953
1100/3200
246x830x830
34(75)650x830x320
59(130)9.52/15.88
25(7.5)15
0~43-7~24R410A
AUY30UU
AOY30UU
230/1/508.409.50
2.95/2.782.85-C3.42-B
13.6/13.13.0
46/44/3953
1250/3300
246x830x830
34(75)830x900x330
69(152)9.52/15.88
30(7.5)15
0~43-7~24R410A
AUY36UU
AOY36UU
400/3/5010.5011.80
3.48/3.653.02-B3.23-C5.9/6.2
4.0 48/44/41
541500/6100
296x830x830
37(82)1165x900x330
94(207)9.52/15.88
50(20)30
0~43-10~24R410A
AUY45UU
AOY45UU
400/3/5012.7014.30
4.38/4.392.90 3.26
7.7/7.75.0
49/47/4354
1550/6100
296x830x830
40(88)1165x900x330
113(249)9.52/19.05
50(20)30
0~43-10~24R410A
AUY54UU
AOY54UU
400/3/5014.5016.50
5.16/5.302.813.11
9.5/9.56.0
52/48/4554
1700/6300
296x830x830
40(88)1290x900x330
118(260)9.52/19.05
50(20)30
0~43-10~24R410A
Model No.Indoor unit
Outdoor unit
StepsAuto Swing
4 3 2 14321
Wide air flowLarger air flap distributes the outlet air flow a longer distance in the horizontal direction.
Flexible installation
Installation is done by “Standard setting“ with more than 300mm (250mm) of space. “Slender setting” lets it suitable for minimum 265mm (215mm) installation space.
Condensate pump lift to 800mm
Optional partsSimple Remote Controller:Additional Grille:
UTY-RSNYMUTG-AGEA-W
ceiling panel
800mm
AUY25UU AUY30UU AUY36UU AUY45UU AUY54UU
Wired R.C.For AUY25UU For AUY30UU
For AUY36/45UU For AUY54UU
Standard setting
Standard setting
Slender setting
250mm 300mm
215mm 265mm
25UU/30UU 36UU/45UU/54UU
Slender settingInstallation Space (Built-in measurement)
Structural objects Structural objects
265300
Ceiling Ceiling
Duct connection hole opening
Fresh air can be introduced through this opening
Conditioned air can be distributed by means of a distribution duct
2-way1-way
Distributionduct
Distribution duct
Fresh air
Easy maintenance
Detachable, washable filter and intake grille
Wide opening and long-life filter
Long-life filter
Long-life filter
High efficiency, long-life filter extends the cleaning cycle.
The control box is easily accessible for maintenance work.Wide opening for easy access.
By placing the electrical component box inside the unit easy maintenance is assured.
(Service staff)
305.5298.5
248.5
200
60 (Dra
inpi
pe)
100
(Sm
a llp
ipe)
70 (Lar
gepi
pe)
305.5298.5
248.5
235
60 (Dra
inp i
pe) Drain inside Dia. ø32
outside Dia. ø37
100
(Sm
allp
ipe )
70 (Lar
gepi
pe)
940
246
30
940 830
830
30
296
750
940
60
(Dra
in p
ipe)
120
285
(Sm
all p
ipe)
150
(Lar
ge p
ipe)
(Sm
all p
ipe)
(Lar
ge p
ipe)
940
830
830
298.5
305.5 248.5
60
(Dra
in p
ipe)
120
250
150
298.5
305.5 248.5
Drain Inside Dia. 32OutsideDia. 37
750
049048
Floor/Ceiling Universal
Specifications Dimensions Models: (Unit : mm)ABYG18LVTB / ABYF24LB
Floor console
Flexible installation
Under ceiling
Example for floor installation Example for ceiling installation
Right and Left Swing
1
2
5
43
5 steps selectable
StepsSwing: Cooling , Dry and Fan modeSwing: Heating and Fan mode
Up and Down Swing1
2
5
4
3
7 steps selectable
6
7
Main work settings can be done easily from the remote controllerat installation
Main work settingsHigh ceiling settingAuto restart Temperature adjustment when cooling / heating
Easy installation
Power Source
Capacity
Input PowerEER - Energy ClassCOP - Energy ClassRunning CurrentMoisture RemovalNoise (Indoor)Noise (Outdoor)Airflow Rate (High)
Piping Connections (Small / Large)Drain Pipe Diameter (I.D./O.D.)Max Pipe Length (Pre-Charge)Height Difference
Refrigerant
Net Dimension H x W x D
OperationRange
CoolingHeating
Cooling/HeatingCoolingHeating
Cooling/Heating
CoolingHeating
CoolingIndoor/Outdoor
Indoor
Outdoor
Cooling H/M/L/Q
m
°CDB
kg(lbs)mm
kg(lbs)mmmm
mm
dB(A)
kW
kW
W/W
AI/h
m3/h
V/Ø/Hz
ABYG18LVTB
AOYG18LA
230/1/505.206.00
1.62/1.663.21-A3.61-A7.2/7.4
2.043/40/34/31
50780/2000
199x990x655
27(60)578x790x300
40(88)6.35/12.70
25/3225(15)
15 -10~46-15~24R410A
ABYF24LB
AOYA24LA
230/1/507.108.00
2.21/2.213.21-A3.61-A9.7/9.7
2.7 48/44/40/35
52980/2470
199x990x655
27(60)578x790x315
44(97)6.35/15.88
25/29.830(15)
20-10~46-15~24R410A
Model No.Indoor unit
Outdoor unit
Double auto swing
A combination of right/left and up/down directional swing allows 3-dimensional air direction control
ABYG18LVTB ABYF24LB
CLASSA
ALLDC
CLASSA
ALLDC
Wireless R.C.
Low ambient operation
Optional parts
Wired Remote Controller:Simple Remote Controller:External Connect Kit:
UTY-RNNYM UTY-RSNYMUTY-XWZX
50
40
30
20
10
0
-10
-15°C
Cooling
24°CHeating
-10°C
46°C
Refrigerant piping flare connection (Liquid)Refrigerant piping flare connection (Gas)Drain piping connection
21
3
12
1
2
33
(18)
051050
Floor/Ceiling Universal
Specifications Dimensions Models: (Unit : mm)
Floor console
Flexible installation
Under ceiling
Example for floor installation Example for ceiling installation
(Unit : mm)
When operation is stopped, the louvres will automatically close. (This function is available on all non-ducted models.)
990 199
655
Symmetrical, slim and compact design.
Compact design
UP and DOWN SWING
RIGHT and LEFT SWING
7 steps selectable
Auto-closing louvre1
2
5
43
12
5
43
6
7
Power Source
Capacity
Input PowerEER - Energy ClassCOP - Energy ClassRunning CurrentMoisture RemovalNoise (Indoor)Noise (Outdoor)Airflow Rate (High)
Piping Connections (Small / Large)Max Pipe Length (Pre-Charge)Height Difference
Refrigerant
Net Dimension H x W x D
OperationRange
CoolingHeating
Cooling/HeatingCoolingHeating
Cooling/Heating
CoolingHeating
CoolingIndoor/Outdoor
Indoor
Outdoor
Cooling H/M/L
m
°CDB
kg(lbs)mm
kg(lbs)mm
mm
dB(A)
kW
kW
W/W
AI/h
m3/h
V/Ø/Hz
ABY18UB
AOY18UB
230/1/505.406.00
1.9/1.852.84-C3.24-C8.6/8.3
2.0 46/41/37
52780/3200
199x990x655
28(62)650x830x320
52(115)6.35/15.88
20(7.5)8
0~43-6~24R410A
ABY24UB
AOY24UB
230/1/506.507.40
2.42/2.302.69-D3.22-C
10.8/10.32.5
49/45/4153
880/3200
199x990x655
28(62)650x830x320
59(130)9.52/15.88
20(7.5)8
0~43-6~24R410A
Model No.Indoor unit
Outdoor unit
ABY18UB ABY24UB
Wireless R.C.
Double auto swing
A combination of up/down and right/left directional swing allows three-dimensional air direction control.
Super vane
Double Louvre Super vane with newly developed special configuration boosts airflow sending cool air quickly to every corner of the room.
Refrigerant piping flare connection (Liquid)Refrigerant piping flare connection (Gas)Drain piping connection
21
3
12
1
2
33
ABY18UB / ABY24UB
053052
Ceiling
Installation Multi auto swing
Specifications Dimensions Models: (Unit : mm)ABYA30LB / ABYA36LB / ABYA45LCABYG36LR / ABYG45LR / ABYG54LR
Optional partsWired Remote Controller:Drain Pump Unit:External Connect Kit:
External Control Set:Flange:
UTY-RNNYMUTR-DPB24TUTY-XWZXUTY-XWZXZ2UTY-XWZXZ3UTD-ECS5AUTD-RF204
ABYA30LB ABYA36LBABYG36LR
CLASSA
ALLDC
CLASSA
ALLDC
ABYA45LCABYG45LR
CLASSA
ALLDC
ABYA54LCABYG54LR
CLASSA
ALLDC
Easily concealed in any installation
Low ambient operation
Condensate lift-up mechanism (Option)
Optional drain lift-up mechanism allows flexible installation.
A combination of right/left and up/down directional swing allows 3-dimensional air direction control.
StepsSwing: Cooling , Dry and Fan modeSwing: Heating and Fan mode
Wireless R.C.
Refrigerant piping flare connection (Liquid)Refrigerant piping flare connection (Gas)Drain piping connection
21
3
For ABYA30/36LB
For ABYA45LC(For single phase)
For ABYG36/45/54LR(For 3 phase)
Right and Left Swing Up and Down Swing
5 steps selectable 5 steps selectable
1
2
5
4
3
12
54
3
(Field Supplied)
Open Concealed
Wall mounted Fresh air intake
OutdoorIndoor
Freshair
Max.
500mm
Easy installation
Main work settings can be done easily from the remote controller at installation
Setting by wireless or wired remote controller
Conventional type
1 2 3
O F F
SW1(Optional parts)
Setting by DIP switch inside control box
Main work settings•High ceiling setting•Auto restart •Temperature adjustment when cooling / heating
1 32
3
Capacity
EER - Energy Class
Running CurrentMoisture Removal
Airflow Rate (High)
Noise (Indoor)
Net Dimension H x W x D
Piping Connections (Small / Large)
Height Difference
Operation Range CoolingHeating
Drain Pipe Diameter (I.D./O.D.)Max Pipe Length (Pre-Charge)
Refrigerant
HeatingCooling/HeatingInput Power
Power SourceCooling
Cooling
Indoor / Outdoor
Cooling H/M/L/QCoolingNoise (Outdoor)
HeatingCooling/Heating
Indoor
Outdoor
°CDB
mm
m
kg(lbs)mm
mm
kW
kg(lbs)
A
W/W
m3/h
I/h
dB(A)
mm
V/ Ø/Hz
kW
ABYA30LB
AOYA30LF
230/1/508.50
10.002.65/2.77
3.21-A3.61-A
11.6/12.22.5
45/43/37/3253
1660/3600240×1660×700
46(101)830x900x330
61(135)9.52/15.8822.0/25.6
50(20)30
-15~46-15~24R410A
Model No.Indoor unit
Outdoor unit
ABYA36LB
AOYA36LF
230/1/509.4011.20
2.93/3.023.21-A3.71-A
12.8/13.23.0
47/43/37/3254
1900/3800240×1660×700
46(101)830x900x330
61(135)9.52/15.8822.0/25.6
50(20)30
-15~46-15~24R410A
ABYG36LR
AOYG36LA
400/3/5010.0011.20
2.84/2.873.52-A3.9-A
4.3/4.43.0
47/43/37/3251
1900/6200240x1660x700
46(101)1290×900×330
105(229)9.52/15.8822.0/25.6
75(30)30
-15~46-15~24R410A
ABYA45LC
AOYA45LC
230/1/5012.0013.30
3.74/3.683.21-A3.61-A
16.4/16.14.5
49/45/39/3455
2100/6750240×1660×700
46(101)1290×900×330
88(194)9.52/15.8822.0/25.6
50(20)30
-15~46-15~24R410A
ABYG45LR
AOYG45LA
400/3/5012.5014.00
3.89/3.883.21-A3.61-A5.8/5.8
4.549/45/39/34
542100/6900
240x1660x70046(101)
1290×900×330105(229)
9.52/15.8822.0/25.6
75(30)30
-15~46-15~24R410A
ABYG54LR
AOYG54LA
400/3/5014.0016.00
4.65/4.673.01-B3.43-B6.9/6.9
5.051/48/42/38
552300/6900
240x1660x70048(106)
1290×900×330105(229)
9.52/15.8822.0/25.6
75(30)30
-15~46-15~24R410A
50
40
30
20
10
0
-10
-15°C
Cooling
24°CHeating
46°C
-15°C
Singlephase
Low noise mode of outdoor unit (45/54 types)2 stage low noise mode can be selected.(Option)
Roted noise value
Mode 1
Mode 2
Lownoisemode
-4dB-2dB
3phase
055054
Ceiling
Specifications Dimensions Models: (Unit : mm)ABY30UB /ABY36UB / ABY45UB / ABY54UB
Installation
Optional drain lift-up mechanism allows flexible installation.
Condensate lift-up mechanism (Option)
Power Source
Capacity
Input PowerEER - Energy ClassCOP - Energy ClassRunning CurrentMoisture RemovalNoise (Indoor)Noise (Outdoor)Airflow Rate (High)
Piping Connections (Small / Large)Max Pipe Length (Pre-Charge)Height Difference
Refrigerant
Net Dimension H x W x D
OperationRange
CoolingHeating
Cooling/HeatingCoolingHeating
Cooling/Heating
CoolingHeating
CoolingIndoor/Outdoor
Indoor
Outdoor
Cooling H/M/L
m
°CDB
kg(lbs)mm
kg(lbs)mm
mm
dB(A)
kW
kW
W/W
AI/h
m3/h
V/Ø/Hz
ABY54UB
AOY54UB
400/3/5014.5016.50
5.16/5.302.813.11
9.5/9.56.0
52/50/4654
2200/6300
240x1660x700
48(106)1290x900x330
118(260)9.52/19.05
50(20)30
0~43-10~24R410A
ABY45UB
AOY45UB
400/3/5012.7014.30
4.38/4.392.90 3.26
7.7/7.75.0
48/46/4154
1850/6100
240x1660x700
48(106)1165x900x330
113(249)9.52/19.05
50(20)30
0~43-10~24R410A
ABY36UB
AOY36UB
400/3/5010.5011.80
3.48/3.453.02-B3.42-B5.9/6.2
4.0 45/42/37
541660/6100
240x1660x700
48(106)1165x900x330
94(207)9.52/15.88
50(20)30
0~43-10~24R410A
ABY30UB
AOY30UB
230/1/508.409.50
2.95/2.782.85-C3.42-B
13.6/13.13.0
42/39/3553
1450/3300
240x1660x700
48(106)830x900x330
69(152)9.52/15.88
30(7.5)15
0~43-7~24R410A
Model No.Indoor unit
Outdoor unit
ABY30UB ABY36UB ABY45UB
Double auto swing and wide airflow
Auto airflow direction and auto swing
Slim & Compact design
ABY54UB
For ABY30UB For ABY36/45UB For ABY54UB
Wireless R.C.
General installation pattern which suspends the indoor unit from the ceiling.
Open
Installation pattern where part of the indoor unit is embedded into the ceiling.
Concealed
Installation which fixes the indoor unit to the wall by the use of wall brackets (Field supplied). This type of installation can be used when the ceiling space is insufficient.
(Field Supplied)
Wall mounted
5 steps selectable
Right and left
1
2
3
45
5 steps selectable
Up and Down Swing
Long Airflow
Long distance air-flow
Long Airflow ensures comfort to every corner of a large room.
High efficiency long-life filter doubles the life of the filter compared to standard filters.
Fresh air intake
240
Long-life filter
OutdoorIndoor
Freshair
Optional parts
Drain Pump Unit: Flange:
Max.
500mm
Refrigerant piping flare connection (Liquid)Refrigerant piping flare connection (Gas)Drain piping connection
21
31 32
3
UTR-DPB24TUTD-RF204
057056
Slim Duct
Specifications Dimensions Models: (Unit : mm)ARYG12LLTB / ARYG14LLTB / ARYG18LLTB
Power Source
Capacity
Input PowerEER - Energy ClassCOP - Energy ClassRunning CurrentMoisture RemovalNoise (Indoor)Noise (Outdoor)Airflow Rate (High)
Piping Connections (Small / Large)Drain Pipe Diameter (I.D./O.D.)Max Pipe Length (Pre-Charge)Height Difference
Refrigerant
Net Dimension H x W x D
OperationRange
CoolingHeating
Cooling/HeatingCoolingHeating
Cooling/Heating
CoolingHeating
CoolingIndoor/Outdoor
Indoor
Outdoor
Cooling
m
°CDB
kg(lbs)mm
kg(lbs)mmmm
mm
dB(A)
kW
kW
W/W
AI/h
m3/h
V/Ø/Hz
ARYG14LLTB
AOYG14LA
198x700x620
19(42)578x790x300
40(88)6.35/12.70
25/3225(15)
15-10~46-15~24R410A
230/1/504.305.00
1.33/1.343.21-A3.71-A6.1/6.1
1.5 32/30/28/26
49800/1910
ARYG18LLTB
AOYG18LA
198x900x620
23(51)578x790x300
40(88)6.35/12.70
25/3225(15)
15-10~46-15~24R410A
230/1/505.206.00
1.62/1.663.21-A3.61-A7.2/7.4
2.0 32/30/29/27
50940/2000
Model No.Indoor unit
Outdoor unit
ARYG12LLTB ARYG14LLTB
CLASSA
ALLDC
CLASSA
ALLDC
ARYG18LLTB
CLASSA
ALLDC
Optional parts
Wired Remote Controller:Simple Remote Controller:IR Receiver Unit:Remote Sensor Unit:External Control Set:Auto Louver Grille Kit:
UTY-RNNYMUTY-RSNYMUTY-LRHYMUTY-XSZXUTD-ECS5AUTD-GXSA-W (For ARYG12 / 14LLTB)
UTD-GXSB-W (For ARYG18LLTB)
*Service accessibility must be allowed for when installing the product. Please consult the installation manual for the necessary service access size.
Wired R.C.
• Slim design with drain pump• Increase static pressure range• Dual concealed type
(Bol
t pitc
h)
F51
152
377
174
713030
ABCD
EF
700650734650
P100x6=600574
ARYG12 / 14LLTB900850934850
P100x8=800774
ARYG18LLTB
78
50
EDC
(Bolt pitch)
43
20
198
168
78
BA
12
69144263371
620
47557889119
167
Air-intake
Back sideBottom side
Air intake direction can be selected to match the installation site.
Slim design
Drain port
This model is slim design, it can install at the place where a ceiling is narrow.
Drain pumpbuilt-in
Height198mm
Drain pump
Drain hose is standard accessory
Max.850mm
Filter (Accessory) Filter (2pcs.)
Flexible installation
Floor concealed
Ceiling concealed
Auto Louver Grille Kit (Option)
Simple flat Auto Louver will provide comfort airflow and harmonize with luxury interior.
Drain pump is standard accessory
It allows flexible installation.
Selectable with a wide range of static pressure
By using DC fan motor, it is possible to change the static pressure range0 to 90Pa. The change of static pressure range is possible by remote controller.
Static pressure range0 to 90 Pa
Wired RemoteController
Wireless RemoteController
4 steps selectable and auto swing
Auto Louver Grille Duct type
Compact Outdoor Unit
ARYG12LLTB
AOYG12LA
230/1/503.504.10
1.05/1.113.33-A3.69-A4.8/5.1
1.3 29/28/26/25
47650/1780
198x700x620
19(42)578x790x300
40(88)6.35/9.52
25/3225(15)
15-10~46-15~24R410A
H/M/L/Q
059058
Compact Duct
Specifications Dimensions Models: (Unit : mm)
Flexible installation
Slim size (217mm) allows installation even where the space behind the ceiling is narrow.
Two-direction drain piping
Air-intake
Filter (Accessory)
Back sideBottom side
Filter (3pcs.)
Air intake direction can be selected to match the installation site.
217
Floor concealed
Ceiling concealed
Two-direction drain pipingDuct indoor unit
ARY18UU
Refrigerant piping flare connection (Gas)Refrigerant piping flare connection (Liquid)Drain piping connection
21
3
*Service accessibility must be allowed for when installing the product. Please consult the installation manual for the necessary service access size.
2
13
Control box
Brackets
Brackets
Airflow outlet
Control box
886(Bolt pitch)
(Bol
t pitc
h)850
390
166
595
2024 47
85
587
194
150
7565
344
953
60094
1021
715
0
886
167
217
Power Source
Capacity
Input PowerEER - Energy ClassCOP - Energy ClassRunning CurrentMoisture RemovalNoise (Indoor)Noise (Outdoor)Airflow Rate (High)
Piping Connections (Small / Large)Max Pipe LengthHeight Difference
Refrigerant
Net Dimension H x W x D
OperationRange
CoolingHeating
Cooling/HeatingCoolingHeating
Cooling/Heating
CoolingHeating
CoolingIndoor/Outdoor
Indoor
Outdoor
Cooling H/M/L
m
°CDB
kg(lbs)mm
kg(lbs)mm
mm
dB(A)
kW
kW
W/W
AI/h
m3/h
V/Ø/Hz
ARY18UU
AOY18UU
230/1/505.406.00
1.92/1.872.81-C3.21-C8.8/8.7
1.6 43/40/36
521000/3200
217x953x595
25(55)650x830x320
52(115)6.35/15.88
208
0~43-6~24R410A
Model No.Indoor unit
Outdoor unit
Compact design
Ultra-slim duct air conditioner for easy installation
ARY18UU
Optional parts
Remote Sensor Unit: UTD-RS100 / UTY-XSZXIR Receiver Unit: UTY-LRJY1Drain Pump Unit: UTZ-PX1BBA
Wired R.C.
Universal Type
Max. length : 10m
IR Receiver unitWireless R.C.
Optional function for comfort
Optional parts
(Bolt pitch)
061060
Medium Static Pressure Duct
Low ambient operation
Slim & Compact design
Specifications Dimensions Models: (Unit : mm)ARYF24LB / ARYA30LB / ARYA36LB / ARYA45LC ARYG36LM / ARYG45LM
In the case of bottom return air connection, not only does the indoor unit design allow for installation in a narrow ceiling space of up to 270mm, Further space savings have been achieved by mounting the electrical control box internally inside the chassis.
Optional partsWired Remote Controller:Flange (Round):Flange (Square):Long Life Filter:Remote Sensor Unit:External Connect Kit:
External Control Set:Drain Pump Unit:IR Receiver Unit:
UTY-RNNYMUTD-RF204UTD-SF045TUTD-LF25NAUTY-XSZXUTY-XWZXZ2UTY-XWZXZ3UTD-ECS5AUTZ-PX1NBAUTY-LRHY1
Wired R.C.
(24) (30/36/45)Singlephase
Easy maintenance
See below for the case of rear suction type
Structural improvement is attained by making the bottom panel two pieces, front and rear. The internal fan casing is also manufactured in two pieces, namely upper and lower. The maintenance of the motor and fan can be easily carried out by removing the rear panel and the lower part of the casing while leaving the main chassis installed.
Two-direction drain piping
Easy installation
Main work settings can be done easily from the remote controller at installation
Setting by wired remote controller Conventional type
1 2 3
O F F
SW1
Setting by DIP switch inside control box
Main work settings•High ceiling setting•Auto restart •Temperature adjustment when cooling / heating
1.Control box2.Fan casing3.Fan4.Motor
Previous model
2
4
13
Large bottom panel: 1 piece
New model 1
4
32
Bottom panel: 2 pieces
1,135mm
1,200mm
270mm
Control box is now included as part of the main chassis
One touch operating and easy to install long life filter (Optional Parts)
For ARYG36/45LM(For 3 phase)
Two-direction drain pipingDuct indoor unit
Refrigerant piping flare connection (Liquid)Refrigerant piping flare connection (Gas)Drain piping connection
21
3
Rear view
Top viewSide view (R)Side view (L)
Front view
2402701071015
1135
17316
1
447(
Bol
t pitc
h)
1177(Bolt pitch)Outlet270
32ø200
(knock out hole)
240
121
P.C.D. ø225
1146632
1
3
3
2
168
281
240
700
138
138
264 264 264
ø205 hole
82
75
ARYF24LB ARYA30LB
CLASSA
ALLDC
CLASSA
ALLDC
ARYA36LBARYG36LM
CLASSA
ALLDC
CLASSA
ALLDC
ARYA45LCARYG45LM
Capacity
EER - Energy ClassCOP - Energy Class Running CurrentMoisture Removal
Airflow Rate (High)
Noise (Indoor)
Net Dimension H x W x D
Piping Connections (Small / Large)
Height Difference
Operation RangeCoolingHeating
Drain Pipe Diameter (I.D./O.D.)Max Pipe Length(Pre-Charge)
Refrigerant
HeatingCooling/HeatingInput Power
Power SourceCooling
Cooling
Indoor / Outdoor
Cooling H/M/L/QCoolingNoise (Outdoor)
HeatingCooling/Heating
Indoor
Outdoor
°CDB
mm
m
kg(lbs)mm
mm
kW
kg(lbs)
A
W/W
m3/h
I/h
dB(A)
mm
V/ Ø/Hz
kW
ARYF24LB
AOYA24LA
230/1/507.108.00
2.21/2.213.21-A3.61-A9.7/9.7
2.531/29/27/25
521100/2470
270x1135x70038(84)
578x790x31544(97)
6.35/15.8836.0/38.0
30(15)20
-10~46-15~24R410A
Model No.Indoor unit
Outdoor unit
ARYA30LB
AOYA30LF
230/1/50 8.50
10.00 2.65/2.68
3.21-A 3.73-A
11.6/11.7 2.5
42/37/32/29 53
2100/3600 270x1135x700
40(88) 830x900x330
61(135) 9.52/15.88 36.0/38.0
50(20) 30
-15~46 -15~24 R410A
ARYA36LB
AOYA36LF
230/1/50 9.40 11.20
2.93/3.1 3.21-A 3.61-A
12.8/13.6 3.0
42/37/32/29 54
2100/3800 270x1 40(88)
830x900x330 61(135)
9.52/15.88 36.0/38.0 50(20)
30 -15~46 -15~24 R410A
ARYG36LM
AOYG36LA
400/3/50 10.00 11.20
2.84/2.87 3.52-A 3.90-A 4.3/4.4
3.0 40/36/31/26
51 1850/6200
270x1135x700 40(88)
1290x900x330 105(229)
9.52/15.88 36.0/38.0 75(30)
30 -15~46 -15~24 R410A
ARYA45LC
AOYA45LC
230/1/50 12.0013.30
3.74/3.68 3.21-A 3.61-A
16.4/16.1 4.5
42/38/32/28 55
2100/6750 270x1135x700
40(88) 1290×900×330
88(194) 9.52/15.88 36.0/38.0 50(20)
30 -15~46 -15~24 R410A
AOYG45LA
400/3/50 12.50 14.00
3.89/3.88 3.21-A 3.61-A 5.8/5.8
4.5 42/38/32/28
54 2100/6900
270x1,135x700 40(88)
1290×900×330 105(229)
9.52/15.88 36.0/38.0 75(30)
30 -15~46 -15~24 R410A
ARYG45LM
For ARYA45LC(For single phase)
For ARYF24LB For ARYA30/36LB
50
40
30
20
10
0
-10
-15°C
Cooling
24°CHeating
46°C
-15°C-10°C (24 type only)
3phase 3phase
063062
Medium Static Pressure Duct
Specifications Dimensions Models: (Unit : mm)ARY25UU / ARY30UU / ARY36U(1) / ARY36UU / ARY45UU
Easy maintenanceTwo-direction drain piping
Two-direction drain piping
Duct indoor unit
See below for the case of rear suction type
1.Control box2.Fan casing
3.Fan4.Motor
Previous model
2
4
13
Large bottom panel: 1 piece
New model 1
4
32
Bottom panel: 2 pieces
Structural improvement is attained by making the bottom panel two pieces, front and rear. The internal fan casing is also manufactured in two pieces, namely upper and lower. The maintenance of the motor and fan can be easily carried out by removing the rear panel and the lower part of the casing while leaving the main chassis installed.
Installation styles
Embedded in Ceiling
Hanging from Ceiling
Power Source
Capacity
Input PowerEER - Energy ClassCOP - Energy ClassRunning CurrentMoisture RemovalNoise (Indoor)Noise (Outdoor)Airflow Rate (High)
Piping Connections (Small / Large)Max Pipe Length (Pre-Charge)Height Difference
Refrigerant
Net Dimension H x W x D
OperationRange
CoolingHeating
Cooling/HeatingCoolingHeating
Cooling/Heating
CoolingHeating
CoolingIndoor/Outdoor
Indoor
Outdoor
Cooling H/M/L
m
°CDB
kg(lbs)mm
kg(lbs)mm
mm
dB(A)
kW
kW
W/W
AI/h
m3/h
V/Ø/Hz
ARY25UU
AOY25UU
230/1/507.007.70
2.65/2.332.64-D3.30-C
11.8/10.52.5
38/36/3453
1100/3200
270x1135x700
43(95)650x830x320
59(130)9.52/15.88
25(7.5)15
0~43-7~24R410A
ARY30UU
AOY30UU
230/1/508.409.50
2.99/2.632.81-C3.61-A
14.0/12.43.0
40/38/3653
1400/3300
270x1135x700
43(95)830x900x330
69(152)9.52/15.88
30(7.5)15
0~43-7~24R410A
ARY36U(1)
AOY36UU(1)
230/1/5010.5012.70
3.60/3.652.92-C3.48-B
16.0/16.53.5
43/41/3954
1750/6100
270x1135x700
43(95)1165x900x330
98(216)9.52/15.88
50(20)30
0~43-10~24R410A
ARY36UU
AOY36UU
400/3/5010.5012.70
3.60/3.652.92-C3.48-B6.1/6.2
3.5 43/41/39
541750/6100
270x1135x700
43(95)1165x900x330
94(207)9.52/15.88
50(20)30
0~43-10~24R410A
ARY45UU
AOY45UU
400/3/5012.7014.30
4.38/4.392.90 3.26
7.7/7.75.0
44/42/4054
1800/6100
270x1135x700
45(99)1165x900x330
113(249)9.52/19.05
50(20)30
0~43-10~24R410A
Model No.Indoor unit
Outdoor unit
ARY25UU ARY30UU ARY36U(1)ARY36UU
Optional parts
Simple Remote Controller: UTY-RSNYMRemote Sensor Unit: UTY-XSZXDrain Pump Unit: UTZ-PX1NBALong Life Filter: UTD-RF204 / UTD-SF045TExternal Control Set: UTD-ECS5A
ARY45UU
For ARY25UU For ARY36U(1)/36/45UU
Wired R.C.
For ARY30UU
*Service accessibility must be allowed for when installing the product. Please consult the installation manual for the necessary service access size.
Refrigerant piping flare connection (Liquid) : Refrigerant piping flare connection (Gas) : Drain piping connection (Drain pipe)
21
3 Rear view
Top viewSide view (R)Side view (L)
Front view
2402701071015
1135
17316
1
447(
Bol
t pitc
h)
1177(Bolt pitch)Outlet270
32ø200
(knock out hole)
240
121
P.C.D. ø225
1146632
1
3
3
2
168
281
240
700
138
138
264 264 264
ø205 hole
82
75
Slim & Compact design
In the case of bottom return air connection, not only does the indoor unit design allow for installation in a narrow ceiling space of up to 270mm, Further space savings have been achieved by mounting the electrical control box internally inside the chassis.
1,135mm
1,200mm
270mm
Control box is now included as part of the main chassis
One touch operating and easy to install long life filter (Optional Parts)
065064
High Static Pressure Duct
Specifications Dimensions Models: (Unit : mm)ARYC45LC / ARYG45LH / ARYC54LC / ARYG54LH
Easy installation (Compact size & Lightweight)Easy installation & maintenance
Low noiseDesign also corresponding to high static pressure
Low ambient operation
Power Source
Capacity
Input PowerEER - Energy ClassCOP - Energy ClassRunning CurrentMoisture RemovalNoise (Indoor)Noise (Outdoor)Airflow Rate (High)
Piping Connections (Small / Large)Drain Pipe Diameter (I.D./O.D.)Max Pipe Length (Pre-Charge)Height Difference
Refrigerant
Net Dimension H x W x D
OperationRange
CoolingHeating
Cooling/HeatingCoolingHeating
Cooling/Heating
CoolingHeating
CoolingIndoor/Outdoor
Indoor
Outdoor
Cooling H/M/L
m
°CDB
kg(lbs)mm
kg(lbs)mmmm
mm
dB(A)
kW
kW
W/W
AI/h
m3/h
V/Ø/Hz
ARYC45LC
AOYA45LC
230/1/5012.5014.00
4.30/3.802.91-C3.68-A
18.9/16.71.5
47/43/4055
3350/6750
400x1050x500
46(101)1290x900x330
88(194)9.52/15.8823.4/25.4
50(20)30
-15~46-15~24R410A
ARYG45LH
AOYG45LA
400/3/5012.5014.00
4.06/3.673.08-B3.81-A6.1/5.5
1.547/43/40
543350/6900
400x1050x500
46(101)1290x900x330
105(229)9.52/15.8823.4/25.4
75(30)30
-15~46-15~24R410A
ARYC54LC
AOYA54LC
230/1/5013.4016.00
4.77/4.692.81-C3.41-B
20.9/20.52.5
47/43/4055
3350/6750
400x1050x500
46(101)1290x900x330
88(194)9.52/15.8823.4/25.4
50(20)30
-15~46-15~24R410A
ARYG54LH
AOYG54LA
400/3/5014.0016.00
4.65/4.373.01-B3.66-A6.9/6.5
2.547/43/40
553350/6900
400x1050x500
46(101)1290x900x330
105(229)9.52/15.8823.4/25.4
75(30)30
-15~46-15~24R410A
Model No.Indoor unit
Outdoor unit
Singlephase
ARYC45LCARYG45LH
ARYC54LCARYG54LH
Optional parts
Wired Remote Controller:Simple Remote Controller:Long-Life Filter:External Connect Kit:
External Control Set:IR Receiver Unit:
UTY-RNNYMUTY-RSNYMUTD-LF60KAUTY-XWZXZ2UTY-XWZXZ3UTD-ECS5AUTY-LRHY1
Wired R.C.
A compact size and lightweight indoor unit has been developed by reducing the basic chassis and the overall material weight.
•4 directions piping connection•Error & operating information are explained by LED display.
Previous model : 75kg
400
8001,250(unit: mm)
400
5001,050
New model : 46kg
Heat exchanger
Plastic fan
Casing (Plastic)
ø225mm
Cutting off the corners has enabled less turbulent air flow.Low noise is realized by adopting a plastic case and a plastic fan.
For ARYC45/54LC(For single phase)
For ARYG45/54LH(For 3 phase)
50
40
30
20
10
0
-10
-15°C
Cooling
24°CHeating
46°C
-15°C
Indoor unit
2 stage low noise mode can be selected.(Option)
Outdoor unit
Roted noise value
Mode 1
Mode 2
Lownoisemode
-4dB-2dB
Volume
down47.5%
Weight
down40%
MAX.
250pa
Front view
Top viewSide view (L)
Side view (R)
Rear view
88
4001,080(Bolt pitch)
1,000862
8511,050 85
371356
208
41 123
139108
1
2
3
4
324 14
295
585
500(
Bol
t pitc
h)
71
Refrigerant piping flare connection (Liquid)Refrigerant piping flare connection (Gas)Drain piping connection
21
3
Med. noise level
43 dB(A)
3phase 3phase
067066
High Static Pressure Duct
Specifications DimensionsModel:
(Unit : mm)
ARY60UU
Model: ARY90TL
1.Wired Remote Controller with Thermo Sensor
1 2 3
• Room temperature sensor selection• WEEKLY timer• Temperature SET BACK timer• Group control system
• Energy saving• Auto changeover (for heating)• Hot start (for heating)
• Child lock• Dual remote controllers <Optional parts>• AUTO restart
3.Remote Sensor (Optional Parts)
Long life filter (Optional Parts)
Output port (Built-in)
Pursuance of amenity performance
Various remote controllers and sensors can be selected
2.Simple Remote Controller (Optional Parts)
Power Source
Capacity
Input PowerEER - Energy ClassCOP - Energy ClassRunning CurrentMoisture RemovalNoise (Indoor)Noise (Outdoor)Airflow Rate (High)
Piping Connections (Small / Large)Max Pipe Length (Pre-Charge)Height Difference
Refrigerant
Net Dimension H x W x D
OperationRange
CoolingHeating
Cooling/HeatingCoolingHeating
Cooling/Heating
CoolingHeating
CoolingIndoor/Outdoor
Indoor
Outdoor
Cooling H/M/L
m
°CDB
kg(lbs)mm
kg(lbs)mm
mm
dB(A)
kW
kW
W/W
AI/h
m3/h
V/Ø/Hz
ARY60UU
AOY60UU
400/3/5016.5019.50
6.06/5.542.723.52
10.2/9.84.0
49/45/4254
3500/6300
400x1050x500
50(110)1290x900x330
118(260)9.52/19.05
50(20)30
0~43-10~24R410A
ARY90TL
AOY90TL
380-415/3/5024.80-25.4028.90-29.50
12.2/12.22.03-2.032.37-2.3619.5/19.5
7.5 50 59
4300/9800
450x1550x700
85(187)1380x1300x650
245(540)12.70/28.58
50(20)30
0~46-10~21R407C
Model No.Indoor unit
Outdoor unit
*The measurement static pressure of ARY60UU is 100Pa and ARY90TL is 196Pa.
ARY60UU
ARY90TL
Optional parts
Simple Remote Controller: UTY-RSNYMLong-Life Filter: UTD-LF60KA (For ARY60UU)
Remote Sensor Unit: UTY-XSZXExternal Control Set: UTD-ECS5A (For ARY60UU)
Design also corresponding to high static pressure
Model: ARY90TL
Wired R.C.
Wired R.C.
Low noise
Turbulent air flow is reduced by cutting off the corners of conventional indoor unit front panel and fan case
Heat exchanger
Plastic fan(ø225mm)
Casing(Plastic)
500mm
400m
m
(ARY60UU)
Plastic fan [45dB(A)] (ARY60UU)
Low noise is realized by adopting plastic case, plastic fan.
* Model : Material (At 100Pa : Actual noise measurement value)
MAX.
300pa
Top view Front view Side view
1,550
1,410
660
713
(MA
X)
700600
450
Front view Top viewSide view (L)
Side view (R)
Rear view
88400 1,080(Bolt pitch)
1,000862
8511,050 85
371356
208
41 123
139108
1
2
3
4
324 14
295
585
500(
Bol
t pitc
h)
71
Refrigerant piping flare connection (Liquid)
Refrigerant piping flare connection (Gas)Drain piping connection
2
1
3
068
Control several indoor units with one outdoor unit.Build the optimum system you desire.
Multi type Line-up
2 & 3-4 Rooms Multi
8 Rooms Multi
Specifications of All Indoor Units
Multi Combination Table
Simultaneous Multi
Big Multi
Optional Parts for Split & Multi Split
070
072
074
078
080
090
092
094
Multi Split type Air ConditionersMultiple Rooms Comfor tably
If you want to keep a large floor as well as many rooms comfortable, we recommend you use Multi Split to build a simple system using one outdoor unit.Choose from a large lineup the air conditioner types that match your rooms.You can mix and match them at will.Build the system that is just right for you.
071070
M u l t i S p l i t
Multi type Line-up
Connectable Indoor unit line-up
Indoor unit features
Multi Split Line-up
14
4 5 5.4
18 24
6.8
30
8
45
14
Capacity range
Model code
Cooling rated capacity(kW)
AOYG14LAC2 AOYG18LAC2
AOYG18LAT3 AOYG24LAT3
Branch box
Separation tube
Outdoor unit
Outdoor unit
Outdoor unit
AOYG30LAT4
AOYG45LAT8
Outdoor unit
(Branch Box)
BTU
Model name
Type
Capacity(kW) Heating
Cooling
Indoor Unit
Outdoor Unit
kW Class
7000
9000
12000
7000
9000
12000
14000
18000
24000
9000
12000
14000
7000
9000
12000
14000
18000
14000
18000
7000
9000
12000
14000
18000
2.0
2.5
3.5
2.0
2.5
3.5
4.0
5.0
7.0
2.5
3.5
4.0
2.0
2.5
3.5
4.0
5.0
4.0
5.0
2.0
2.5
3.5
4.0
5.0
3 Rooms2 Rooms
ASYG07/09/12LJ
ASYG18/24LF
AGYG09/12/14LV
AUYG07/09/12/14/18LV
ABYG14/18LV
ARYG07/09/12/14/18LL
AOYG14LAC2
4.0
4.4
AOYG18LAC2
5.0
5.6
AOYG18LAT3
5.4
6.8
AOYG24LAT3
6.8
8.0
AOYG30LAT4
4 Rooms
8.0
9.6
AOYG45LAT8
8 Rooms
14.0
16.0
●●●●●●�
�
�
●●�
●●●�
�
�
�
●●●�
�
●●●●●●●�
�
●●●●●●●�
●�
●●●●�
●●●●●●●●�
●●●●●●●●●●●●●●●
●●●●●●●●●●●●●●●●●●●●●●●●
●●●●●●●●●●●●●●●●●●●●●●●●
●●●●●●�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
�
8 Rooms Multi Up to 8 units
4 Rooms Multi Up to 4 units
3 Rooms Multi Up to 3 units
2 Rooms Multi Up to 2 units
Note : 1. 2 Rooms Multi : Connectable indoor units are 2 units. AOYG14LAC2 : Total capacity of indoor units connected must be between 4.0kW and 6.2kW. AOYG18LAC2 : Total capacity of indoor units connected must be between 4.0kW and 7.0kW. 2. 3 Rooms Multi : Connectable indoor units are 2 to 3 units. AOYG18LAT3 : Total capacity of indoor units connected must be between 4.0kW and 8.5kW. AOYG24LAT3 : Total capacity of indoor units connected must be between 4.0kW and 10.5kW. 3. 4 Rooms Multi : Connectable indoor units are 3 to 4 units. AOYG30LAT4 : Total capacity of indoor units connected must be between 7.9kW and 14.4kW. 4. 8 Rooms Multi : Connectable indoor units are 2 to 8 units. AOYG45LAT8 : Total capacity of indoor units connected must be between 11.2kW and 18.2kW.
ASYG07/09/12LJASYG07/09/12/14LUASYG18/24LFAGYG09/12/14LVAUYG07/09/12/14/18LVABYG14/18LVARYG07/09/12/14/18LL
●●●●
●
●
●●●●●●●
●●●●●●●
●●●●●●●
●●●●●● ●
●●●●●●●
● ●●●●●●●
●
●
●●●●●●●
●●●●
●●●●
●●●
: Optional function
●●●●●●
●
ASYG07/09/12/14LU
Low noisePOWERFULPOWERFUL
073072
2 & 3-4 Rooms Multi
3 ROOMS 4 ROOMS
AOYG18LAT3AOYG24LAT3
2 ROOMS
AOYG14LAC2AOYG18LAC2
CLASSA
ALLDC
CLASSA
ALLDC
CLASSA
ALLDC
AOYG30LAT4
Space-saving installation
Flexible installation
Multiple indoor units can be connected to 1 outdoor unit, and long piping connection is also possible. Compared with single type, the outdoor unit can be installed in various places to realize the space-saving installation.
Up to max. piping length 70m (AOYG30LAT4), max. height difference 15m can be supported. Multi type can be installed at large-size residence or multiple floors.
Wide range of indoor units with various models6 types, 20 models are lined up in the capacity range from 2kW to 7kW class.The wide-ranging needs can be met from the private room of residence or hotel to large shop.
Max.Piping Length (Each Unit):20m (AOYG14LAC2 / 18LAC2), 25m (AOYG18LAT3 / 24LAT3 / 30LAT4)
Max.Height:15m (AOYG14LAC2 / 18LAC2 / 18LAT3 / 24LAT3/30LAT4)
2 ROOMSModel: AOYG14LAC2 / AOYG18LAC2
4 ROOMS Models: AOYG30LAT4
3 ROOMS Models: AOYG18LAT3 / AOYG24LAT3
Top view
Front viewSide viewBottom view
900
650
2183
0
9
40 31 12330
400
41
12
94
57 114
(493
)11
4 x
3 =3
42
5
370
Top view
Front view
Bottom view
Side view
900
21
700
9
40
650
370
31 12330
400
41
12 94
57 114
228
Top view
540
Front view
Bottom view
Side view
288
352
19107279020
541
57
318
114
87
20
9
Air Flow
SPECIFICATIONS (2 ROOMS, 3 ROOMS, 4 ROOMS)
* Connect to connection valve by the adapter.
Power Source
OperationRangeRefrigerant
Net Dimension H x W x DWeight
Piping Connections
Max. length
Max. Height Difference
CoolingHeatingCoolingHeating
CoolingHeating
mmkg(lbs)
mm
m
°CDB
V/Ø/Hz
Outdoor unitModel No.
Between Outdoor Unit and Each Indoor Units.Between Indoor Units.
AOYG14LAC2
230/1/504.0(1.4~4.4)4.4(1.1~5.4)
4749
540x790x29037(82)
Ø6.35x2
Ø9.52x2
15
1010~46-15~24R410A
30 / 20
15
10
AOYG18LAT3
230/1/505.4(1.8~6.8)6.8(2.0~7.7)
4647
700x900x33055(121)
Ø6.35x3
Ø9.52x2, Ø12.7 *(Ø9.52x3)
-10~46-15~24R410A
50 / 25
AOYG24LAT3
230/1/506.8(1.8~7.8)8.0(2.0~8.0)
4849
700x900x33055(121)
Ø6.35x3
Ø9.52x2, Ø12.7 *(Ø9.52x3)
15
10-10~46-15~24R410A
50 / 25
AOYG30LAT4
230/1/508.0(3.5~10.0)9.6(3.7~11.3)
5051
830x900x33068(150)Ø6.35x4
(*Ø6.35x3, Ø9.52)
Ø9.52x2, Ø12.7x2 *(Ø9.52x3, Ø12.7)
*(Ø9.52x2, Ø12.7, Ø15.88)
15
100~46
-10~24R410A
70 / 25
AOYG18LAC2
230/1/505.0(1.7~5.6)5.6(1.8~6.1)
5051
540x790x29038(84)
Ø6.35x2
Ø9.52x2 *(Ø9.52, Ø12.7)
15
30 / 20
1010~46-15~24R410A
Small (Liquid)
Large (Gas)
Con
nect
ion
pipe
Total / Each
Noise
Rated Capacity(min-max)
dB(A)
kW
Total Piping Length:30m (AOYG14LAC2 / 18LAC2), 50m (AOYG18LAT3 / 24LAT3), 70m (AOYG30LAT4)
Ex.) Single type installation
3 outdoor units 1 outdoor unit
Multi type installation
075074
8 Rooms Multi
AOYG45LAT8
ALLDC
High Efficiency & Compact
Innovated technologyCompact outdoor unit
Central Remote Controller
More Comfort
Every room meet set point most quickly and comfortably by optimized refrigerant control.
Quick comfort by optimized refrigerant control
•Suitable for large homes, shops, small buildings, and a variety of other multi installations
•Up to 8 indoor units can be connected•Excellent installability, lightweight, compact yet high efficiency operation outdoor unit
High efficiency DC twin rotary compressor : A high performance, low noise, large capacity DC twin rotary compressor is used.
Heat exchanger : Reduced compact size and energy saving has been realized by utilizing high density piping design and 3-Row heat exchanger.
High efficiency large fan : New high efficiency fan is mounted.
DC fan motor : High performance and high efficiency has been realized by using a small DC fan motor.
1290mm
914mm
About 14kW class multi split model
New modelHeight difference
29%
Refrigerant control by branch box
Meet set point
Increasecapacity
Decreasecapacity
Increasecapacity
Decreasecapacity
Meet set point
All operation start
The actual performance is conducted under various outside temperatures depending on weather and seasons, furthermore, especially for multi system, not all the rooms are operated all the time. So over 90% of actual operation time, air conditioners are operated at partial capacity instead of rated capacity.Considering these, we focused on energy-saving performance which is based on actual use.Efficiency of part load performance was drastically improved by developing ALL DC and our own inverter system.
High seasonal efficiency
(50% load)EER4.75EER
frequency operation range
5
3
1
0
Part load(%)25 50 75 100 %
4.75
Central remote controller developed for residential applications.All indoor units can be batched controlled using simple operations. Schedule management and other functions can be used to achieve even greater energy savings.
UTY-DMMYM
Central & Individual ControlBatched control of up to 8 indoor units. The temperature, airflow volume, and remote control prohibition settings of all indoor units can be batched.
User-friendly operation• Large backlight LED screen• Large easy-to-see operation panel
Corresponds to 9 different languages (English, German, French, Spanish, Russian, Portuguese, Italian, Greek, and Turkish)
Multiple language support
UTY-DMMYM
Power & Transmission line
Outdoor unit
Indoor unit
R.C.
Branch box
Remote controller cable
Controllable
1multi systemMax. Controllable
8 indoor units
System configuration
Setting the address is not required* When the indoor units are connected to a branch box, the addresses for each indoor unit are set automatically.
*Note : Cross-over connections are not allowed in the refrigerant system. Group settings are not allowed.
Transmission line
10ºC heat operation
Prohibited Settings
The remote controller operation of all indoor units comes with a lock function to prevent unapproved operations in the various rooms. The central remote controller also has a key lock function to prevent children from playing with it, etc
When you leave, minimum heating operation is performed to maintain the room temperature (maintain at 10ºC).
Economy operation
Economy operation is energy saving, as the set temperature of indoor unit is shifted by 1°C and the maximum electric value of the outdoor unit is suppressed.
Tem
p.
Economy operation
Shift setting temp
Normal operation
Time
Set temperature
10°C
20°C
10ºC heatbutton
Indoor unit operation
ON
START
Low noise operation
Users can choose from 4 low noise levels, depending on the installation environment. The operation time can be set using the timer.
Air conditioning load factor
Capacity
Operating sound
time
100%
58dB
0
0
Heat load
down
Quiet priority low noise mode
Quiet priority setting
Weekly schedule timer
The ON/OFF setting can be set for 4 times a day. Two weekly patterns can be set to match the cooling and heating seasons.
Monday~Friday Saturday~Sunday
7Time
Time
12 17 23
Summerseasonpattern
Winterseasonpattern
Cool Cool Cool
8 1 18 22
Cool Cool Cool
7 1213 23
Heat
Heat
Heat
7 1 18 23
Heat Heat Heat
Option
077076
8 Rooms Multi
Flexible Design & Easy Installation
Large capacity connectionUp to 8 indoor units can be connected to one outdoor unit. A maximum of 130% indoor unit connectable capacity. Match any room layout
Connectableindoor unit number
Up to 8
Total pipe length
115m max.
Connectableindoor unit capacity
Ratio up to 130%
Branch box
Separation tubeOutdoor unit
Can be installed in high rise condominium or commercial building
Actual pipe length70m max.
Height difference betweenO.U. and I.U.30m max.
Height differencebetween I.U. and I.U.
15m max.
Pipe length betweenI.U. and Branch box
15m max.
Long piping design
Indoor unit
Branch boxSeparation tube
All flare piping connection and simple installation that minimizes wiring mistakes.
Power & Transmission lineTransmission line
Outdoor unit
Powersource
Power supply
Piping
Wiring mistake automatic check functionThe check operation detects wiring mistakes in advance.
Simple wiring connection that is not cross connectionWiring connection is the same as single split or multi type.
Branch box
Simple all flare piping connection
Branch Box can be mounted flexibly.Allowed Branch Box Mounting Direction
HorizontalWall Mounting
VerticalWall Mounting
Install the unit with its top side facing upwards.
Install the unit with the control box facing upwards.
Hanging from the ceiling
Do not hang from the ceiling when performing a vertical installation.
DimensionsOutdoor UnitAOYG45LAT8
Branch BoxUTP-PY03A(3 branches type)
Branch BoxUTP-PY02A(2 branches type)
(Unit : mm)650
970 24 370 12
166
370
24
401
440
914
21
24
Specifications
m3/h
kW
kW
mm
kg(Ibs)
mm
m
°CDB
dB(A)
kW
Rated Capacity
Input Power
Power source V/ Ø/Hz
Cooling
Heating
Cooling
Heating
Cooling
Heating
Cooling
Heating
CoolingIndoor unit connectable capacity
Air flow rate
Net Dimensions H x W x DWeight
Piping Connections (Small / Large)
Max Pipe Length
Max Height Difference (O.U ~ I.U)
Operating range
Refrigerant
Sound pressure level
Heat exchanger fin
Cooling
Heating
AOYG45LAT8
8
11.2 - 18.2
230/1/50
14.0
16.0
5.20
5.07
4,650
4,800
56
58
Plate fin coil
914 x970x370
98 (217)
9.52/15.88
115 (Total)
30
-5 to 46
-15 to 24
R410A
Model name
Maximum Connectable Indoor Unit
UTP-PY03A
1 to 3 Units
1Ø 230V ~50Hz
198-264V
10
0.05
195x433x370
9
Main: 9.52x1, Branch:6.35x3
Main: 15.88x1, Branch:12.7x3
Flare
UTP-PY02A
1 to 2 Units
1Ø 230V ~50Hz
198-264V
10
0.05
195x433x370
9
Main: 9.52x1, Branch:6.35x2
Main: 15.88x1, Branch:12.7x2
Flare
Model name
Connectable indoor unit
Power source
Available voltage range
Powwer consumption
Running currrent
Dimensions (HxWxD)
Weight
W
A
mm
kgLiquid
GasConnectionpipe
Note: Specifications are based on the following conditions.Power source of specifications: 230V.
Size mm
Method
214
469
469
432
433 75
1958568
95
256 37
214
825
7570
959557
24
174154
110
134
216256
176469
469
432
433 75
1958568
95 372
148
25
7570
95
152
24
174154
110
134
216176
079078
Specifications of All Indoor Units
kW Class Power Source
Net DimensionWeightPipe Size
Noise
Air Flow
H/M/L/Q
H/M/L/Q
dB(A)
m3/h
Cooling
Heating
CoolingHeating
Liquid/Gas
kWV/Ø/Hz
mmkg(lbs)
mm
ABYG14LV
4.0230/1/50
36/34/33/29(Under ceiling)39/37/36/32(Floor console)36/34/33/29(Under ceiling)39/37/36/32(Floor console)
640/590/540/480640/590/540/480
199x990x65527(60)
Ø6.35/Ø12.7
ABYG18LV
5.0230/1/50
41/38/34/32(Under ceiling)44/41/37/35(Floor console)41/38/34/32(Under ceiling)44/41/37/35(Floor console)
780/700/560/500780/700/560/500
199x990x65527(60)
Ø6.35/Ø12.7
Indoor unitModel No.
kW Class Power Source
Net DimensionWeightPanel Pipe Size
Noise
Air Flow
H/M/L/Q
H/M/L/Q
dB(A)
m3/h
CoolingHeatingCoolingHeating
Liquid/Gas
kWV/Ø/Hz
mmkg(lbs)
mm
AUYG07LV
2.0230/1/50
33/31/29/2734/32/29/27
540/490/440/390540/490/440/390
245x570x57015(33.1)
Ø6.35/Ø9.52
AUYG09LV
2.5230/1/50
33/31/29/2734/32/29/27
540/490/440/390540/490/440/390
245x570x57015(33.1)
Ø6.35/Ø9.52
AUYG14LV
4.0230/1/50
40/35/32/2940/37/34/29
680/580/490/410700/620/550/430
245x570x57015(33.1)
Ø6.35/Ø12.7
AUYG12LV
3.5230/1/50
37/33/31/2837/33/31/28
610/530/470/410610/530/470/410
245x570x57015(33.1)
UTG-UFYD-WØ6.35/Ø9.52
AUYG18LV
5.0230/1/50
42/37/33/2944/40/37/30
750/610/520/410800/710/600/450
245x570x57015(33.1)
Ø6.35/Ø12.7
Indoor unitModel No.
kW Class Power Source
Net DimensionWeightPipe SizeExternal static pressureDrain pump
Noise
Air Flow
H/M/L/Q
H/M/L/Q
dB(A)
m3/h
CoolingHeatingCoolingHeating
Liquid/Gas
kWV/Ø/Hz
mmkg(lbs)
mm
ARYG07LL
2.0230/1/50
28/26/25/2428/26/25/24
550/490/470/440550/490/470/440
198x700x62017(37.5)
Ø6.35/Ø9.52
ARYG09LL
2.5230/1/50
28/27/26/2528/26/25/24
600/550/500/450600/550/500/450
198x700x62019(41.8)
Ø6.35/Ø9.52
ARYG14LL
4.0230/1/50
32/30/28/2633/30/28/25
800/700/600/480800/700/600/480
198x700x62019(41.8)
Ø6.35/Ø12.7
ARYG12LL
3.5230/1/50
29/28/27/2629/28/27/24
650/600/550/480650/600/550/480
198x700x62019(41.8)
Ø6.35/Ø9.520 to 90
Standard
ARYG18LL
5.0230/1/50
32/31/30/2933/32/31/29
940/880/820/750940/880/820/750
198x900x62023(50.6)
Ø6.35/Ø12.7
Indoor unitModel No.
kW Class Power Source
Net DimensionWeightPipe Size
Noise
Air Flow
H/M/L/Q
H/M/L/Q
dB(A)
m3/h
CoolingHeatingCoolingHeating
Liquid/Gas
kWV/Ø/Hz
mmkg(lbs)
mm
ASYG07LU
2.0230/1/50
35/30/28/2135/30/28/21
570/520/470/330570/520/470/330
282x870x1859.5(21)
Ø6.35/Ø9.52
ASYG09LU
2.5230/1/50
36/32/28/2136/32/28/21
600/550/470/330600/550/470/330
282x870x1859.5(21)
Ø6.35/Ø9.52
ASYG12LU
3.5230/1/50
37/34/31/2137/34/31/21
660/600/530/330660/600/530/330
282x870x1859.5(21)
Ø6.35/Ø9.52
ASYG14LU
4.0230/1/50
41/36/33/2541/36/34/27
710/640/570/390710/640/590/430
282x870x1859.5(21)
Ø6.35/Ø12.7
Indoor unitModel No.
kW Class Power Source
Net DimensionWeightPipe Size
Noise
Air Flow
H/M/L/Q
H/M/L/Q
dB(A)
m3/h
Cooling
Heating
CoolingHeating
Liquid/Gas
kWV/Ø/Hz
mmkg(lbs)
mm
Indoor unitModel No.
kW Class Power Source
Net DimensionWeightPipe Size
Noise
Air Flow
H/M/L/Q
H/M/L/Q
dB(A)
m3/h
CoolingHeatingCoolingHeating
Liquid/Gas
kWV/Ø/Hz
mmkg(lbs)
mm
ASYG07LJ
2.0230/1/50
36/32/29/2136/32/29/22
560/500/430/310560/500/430/330
280x790x2038(17.6)
Ø6.35/Ø9.52
ASYG09LJ
2.5230/1/50
37/33/29/2137/33/29/22
600/520/430/310600/520/430/330
280x790x2038(17.6)
Ø6.35/Ø9.52
ASYG18LF
5.0230/1/50
43/37/33/2642/37/33/25
900/740/620/550900/740/620/550
320x998x23814(30.8)
Ø6.35/Ø12.7
ASYG12LJ
3.5230/1/50
40/36/30/2140/36/31/22
660/560/450/310660/560/470/330
280x790x2038(17.6)
Ø6.35/Ø9.52
ASYG24LF
7.0230/1/50
49/42/37/3348/42/37/33
1120/900/740/6201100/900/740/620
320×998×23814(30.8)
Ø6.35/Ø15.88
Indoor unitModel No.
AGYG09LV
2.5230/1/50
39/34/28/22
39/35/30/22
530/440/360/270 530/460/380/270
600x740x20014(30.7)
Ø6.35/Ø9.52
AGYG12LV
3.5230/1/50
42/36/30/22
42/38/32/22
600/490/380/270600/510/410/270
600x740x20014(30.7)
Ø6.35/Ø9.52
AGYG14LV
4.0230/1/50
44/38/31/22
44/39/33/22
650/520/400/270650/540/430/270
600x740x20014(30.7)
Ø6.35/Ø12.7
Compact wall mounted Floor ceiling
Compact cassette Wall mounted
Floor Slim duct
081080
Multi Combination Table
791277799
---79
129
12
1Room
2Room
COOLING OPERATIONCooling Capacity
Room 1KW
Room 2KW
Total Capacity (min-max)KW
EER Energy efficiency class
KW
Input Power (min-max)AOYG14LAC2
2.10 2.50 3.50 2.00 1.95 1.65 2.00 1.70
---
2.00 2.05 2.35 2.00 2.30
2.10 ( 1.2 - 2.7 )2.50 ( 1.2 - 3.2 )3.50 ( 1.2 - 3.7 )4.00 ( 1.4 - 4.4 )4.00 ( 1.4 - 4.4 )4.00 ( 1.4 - 4.6 )4.00 ( 1.4 - 4.5 )4.00 ( 1.4 - 4.7 )
0.59 ( 0.30 - 0.76 )0.65 ( 0.30 - 1.03 )1.04 ( 0.30 - 1.21 )1.09 ( 0.35 - 1.40 )1.09 ( 0.35 - 1.40 )1.05 ( 0.35 - 1.47 )1.09 ( 0.35 - 1.43 )1.05 ( 0.35 - 1.47 )
3.56 3.85 3.37 3.67 3.67 3.81 3.67 3.81
AAAAAAAA
Combination of indoor unit
79127779912
---79
129
1212
2.10 2.50 3.50 2.10 2.10 1.90 2.50 2.10 2.50
---
2.10 2.50 3.10 2.50 2.90 2.50
2.10 ( 1.4 - 2.7 )2.50 ( 1.4 - 3.2 )3.50 ( 1.4 - 3.7 )4.20 ( 1.7 - 5.2 )4.60 ( 1.7 - 5.3 )5.00 ( 1.7 - 5.6 )5.00 ( 1.7 - 5.6 )5.00 ( 1.7 - 5.7 )5.00 ( 1.7 - 5.8 )
0.48 ( 0.30 - 0.72 )0.64 ( 0.30 - 1.05 )1.02 ( 0.30 - 1.34 )1.24 ( 0.35 - 1.68 )1.26 ( 0.35 - 1.79 )1.55 ( 0.35 - 1.95 )1.56 ( 0.35 - 1.95 )1.55 ( 0.35 - 1.95 )1.56 ( 0.35 - 1.99 )
4.38 3.94 3.43 3.39 3.65 3.23 3.21 3.23 3.21
AAAAAAAAA
1Room
2Room
COOLING OPERATIONCooling Capacity
Room 1KW
Room 2KW
Total Capacity (min-max)KW
EER Energy efficiency class
KW
Input Power (min-max)AOYG18LAC2 Combination of indoor unit
79121479121491214121479121491214912
----77779991212777799999
-------------777777799
2.30 2.70 3.50 4.20 2.30 2.70 3.02 3.42 2.50 2.82 3.23 2.55 2.89 1.80 2.00 2.33 2.58 1.89 2.22 2.47 1.80 2.12
----
2.30 2.30 1.98 1.88 2.50 2.18 2.07 2.55 2.41 1.80 1.70 1.53 1.41 1.89 1.72 1.58 1.80 1.64
-------------
1.80 1.70 1.53 1.41 1.61 1.46 1.35 1.80 1.64
2.30 ( 1.5 - 2.7 )2.70 ( 1.5 - 3.3 )3.50 ( 1.5 - 3.7 )4.20 ( 1.5 - 4.8 )4.60 ( 1.8 - 5.0 )5.00 ( 1.8 - 5.7 )5.00 ( 1.8 - 6.1 )5.30 ( 1.8 - 6.6 )5.00 ( 1.8 - 6.2 )5.00 ( 1.8 - 6.3 )5.30 ( 1.8 - 6.7 )5.10 ( 1.8 - 6.3 )5.30 ( 1.8 - 6.7 )5.40 ( 1.8 - 6.8 )5.40 ( 1.8 - 6.8 )5.40 ( 1.8 - 6.8 )5.40 ( 2.0 - 6.8 )5.40 ( 1.8 - 6.8 )5.40 ( 1.8 - 6.8 )5.40 ( 2.0 - 6.8 )5.40 ( 1.8 - 6.8 )5.40 ( 1.8 - 6.8 )
0.65 ( 0.45 - 0.75 )0.80 ( 0.45 - 1.09 )1.09 ( 0.45 - 1.15 )1.16 ( 0.45 - 1.41 )1.22 ( 0.50 - 1.43 )1.35 ( 0.50 - 1.81 )1.34 ( 0.50 - 2.06 )1.34 ( 0.50 - 2.06 )1.35 ( 0.50 - 2.06 )1.35 ( 0.50 - 2.06 )1.35 ( 0.50 - 2.06 )1.35 ( 0.50 - 2.06 )1.35 ( 0.50 - 2.06 )1.34 ( 0.50 - 2.06 )1.35 ( 0.50 - 2.06 )1.35 ( 0.50 - 2.06 )1.35 ( 0.60 - 2.06 )1.35 ( 0.50 - 2.06 )1.35 ( 0.50 - 2.06 )1.35 ( 0.60 - 2.06 )1.35 ( 0.50 - 2.06 )1.35 ( 0.50 - 2.06 )
3.54 3.38 3.21 3.62 3.77 3.70 3.73 3.96 3.70 3.70 3.93 3.78 3.93 4.03 4.00 4.00 4.00 4.00 4.00 4.00 4.00 4.00
AAAAAAAAAAAAAAAAAAAAAA
1Room
2Room
3Room
COOLING OPERATIONCooling Capacity
Room 1KW
Room 2KW
Room 3KW
Total Capacity (min-max)KW
EER Energy efficiency class
KW
Input Power (min-max)AOYG18LAT3 Combination of indoor unit
79121418791214189121418121418791214189121418121491214
18*1
121412
-----77777999912121277777999912129999121212
-----------------77777777777999999
12
2.30 2.70 3.50 4.20 5.00 2.30 2.70 3.42 4.13 4.52 2.75 3.41 3.94 4.35 3.15 3.67 4.04 2.27 2.52 2.84 3.16 3.54 2.38 2.70 3.02 3.40 2.52 2.83 2.27 2.58 2.89 3.27 2.41 2.72 2.27
-----
2.30 2.30 2.38 2.37 2.08 2.75 2.79 2.66 2.35 3.15 3.03 2.66 2.27 2.14 1.98 1.82 1.63 2.38 2.21 2.04 1.84 2.52 2.34 2.27 2.11 1.95 1.77 2.41 2.24 2.27
-----------------
2.27 2.14 1.98 1.82 1.63 2.03 1.88 1.74 1.56 1.76 1.63 2.27 2.11 1.95 1.77 1.97 1.84 2.27
2.30 ( 1.5 - 2.7 )2.70 ( 1.5 - 3.3 )3.50 ( 1.5 - 3.7 )4.20 ( 1.5 - 4.8 )5.00 ( 1.8 - 5.6 )4.60 ( 1.8 - 5.0 )5.00 ( 1.8 - 5.7 )5.80 ( 1.8 - 6.1 )6.50 ( 1.8 - 7.2 )6.60 ( 1.8 - 7.8 )5.50 ( 1.8 - 6.2 )6.20 ( 1.8 - 6.8 )6.60 ( 1.8 - 7.7 )6.70 ( 1.8 - 7.9 )6.30 ( 1.8 - 7.2 )6.70 ( 1.8 - 7.8 )6.70 ( 1.8 - 7.9 )6.80 ( 1.8 - 7.4 )6.80 ( 1.8 - 7.8 )6.80 ( 1.8 - 8.1 )6.80 ( 2.0 - 8.4 )6.80 ( 2.0 - 8.5 )6.80 ( 1.8 - 8.2 )6.80 ( 1.8 - 8.2 )6.80 ( 2.0 - 8.4 )6.80 ( 2.0 - 8.5 )6.80 ( 1.8 - 8.2 )6.80 ( 2.0 - 8.5 )6.80 ( 1.8 - 8.2 )6.80 ( 1.8 - 8.3 )6.80 ( 2.0 - 8.5 )6.80 ( 2.0 - 8.5 )6.80 ( 1.8 - 8.3 )6.80 ( 2.0 - 8.5 )6.80 ( 1.8 - 8.3 )
0.65 ( 0.45 - 0.75 )0.80 ( 0.45 - 1.09 )1.09 ( 0.45 - 1.15 )1.16 ( 0.45 - 1.41 )1.50 ( 0.50 - 1.96 )1.20 ( 0.50 - 1.40 )1.36 ( 0.50 - 1.78 )1.70 ( 0.50 - 1.97 )1.91 ( 0.50 - 2.46 )1.91 ( 0.50 - 2.87 )1.55 ( 0.50 - 2.02 )1.90 ( 0.50 - 2.45 )1.91 ( 0.50 - 2.77 )1.91 ( 0.50 - 2.87 )1.90 ( 0.50 - 2.74 )1.91 ( 0.50 - 2.87 )1.92 ( 0.50 - 2.87 )1.92 ( 0.50 - 2.37 )1.93 ( 0.50 - 2.60 )1.93 ( 0.50 - 2.87 )1.94 ( 0.60 - 2.87 )1.94 ( 0.60 - 2.87 )1.93 ( 0.50 - 2.87 )1.93 ( 0.50 - 2.87 )1.94 ( 0.60 - 2.87 )1.94 ( 0.60 - 2.87 )1.94 ( 0.50 - 2.87 )1.94 ( 0.60 - 2.87 )1.94 ( 0.50 - 2.87 )1.94 ( 0.50 - 2.87 )1.94 ( 0.60 - 2.87 )1.94 ( 0.60 - 2.87 )1.94 ( 0.50 - 2.87 )1.94 ( 0.60 - 2.87 )1.94 ( 0.50 - 2.87 )
3.54 3.38 3.21 3.62 3.33 3.83 3.68 3.41 3.40 3.46 3.55 3.26 3.46 3.51 3.32 3.51 3.49 3.54 3.52 3.52 3.51 3.51 3.52 3.52 3.51 3.51 3.51 3.51 3.51 3.51 3.51 3.51 3.51 3.51 3.51
AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA
1Room
2Room
3Room
COOLING OPERATIONCooling Capacity
Room 1KW
Room 2KW
Room 3KW
Total (min-max)KW
EER Energy efficiency class
KW
Input Power (min-max)AOYG24LAT3 Combination of indoor unit
1Room
2Room
HEATING OPERATIONHeating Capacity
Room 1KW
Room 2KW
Total Capacity (min-max)KW
COP Energy efficiency class
KW
Input Power (min-max)AOYG14LAC2
79
1277799
---79
129
12
2.70 ( 0.9 - 3.3 )3.30 ( 0.9 - 4.2 )4.00 ( 0.9 - 4.8 )4.40 ( 1.1 - 5.4 )4.40 ( 1.1 - 5.4 )4.40 ( 1.1 - 5.5 )4.40 ( 1.1 - 5.4 )4.40 ( 1.1 - 5.5 )
0.64 ( 0.25 - 0.89 )0.87 ( 0.25 - 1.37 )1.13 ( 0.25 - 1.59 )1.03 ( 0.25 - 1.78 )1.03 ( 0.25 - 1.78 )1.02 ( 0.25 - 1.76 )1.03 ( 0.25 - 1.78 )1.02 ( 0.25 - 1.76 )
4.22 3.79 3.54 4.27 4.27 4.31 4.27 4.31
AAAAAAAA
2.70 3.30 4.00 2.20 2.15 1.95 2.20 2.00
---
2.20 2.25 2.45 2.20 2.40
Combination of indoor unit
1Room
2Room
HEATING OPERATIONHeating Capacity
Room 1KW
Room 2KW
Total Capacity (min-max)KW
COP Energy efficiency class
KW
Input Power (min-max)AOYG18LAC2
2.70 ( 1.4 - 3.3 )3.30 ( 1.4 - 4.2 )4.00 ( 1.4 - 4.8 )5.40 ( 1.8 - 6.0 )5.50 ( 1.8 - 6.0 )5.60 ( 1.8 - 6.1 )5.60 ( 1.8 - 6.1 )5.60 ( 1.8 - 6.2 )5.60 ( 1.8 - 6.3 )
0.64 ( 0.40 - 1.07 )0.92 ( 0.40 - 1.47 )1.14 ( 0.40 - 1.70 )1.24 ( 0.50 - 1.61 )1.36 ( 0.50 - 1.87 )1.38 ( 0.50 - 1.88 )1.41 ( 0.50 - 1.90 )1.38 ( 0.50 - 1.88 )1.34 ( 0.50 - 1.84 )
4.22 3.61 3.51 4.37 4.04 4.06 3.97 4.07 4.18
AABAAAAAA
2.70 3.30 4.00 2.70 2.50 2.30 2.80 2.45 2.80
---
2.70 3.00 3.30 2.80 3.15 2.80
Combination of indoor unit
79
1277799
12
---79
129
1212
1Room
2Room
3Room
HEATING OPERATIONHeating Capacity
Room 1KW
Room 2KW
Room 3KW
Total Capacity (min-max)KW
COP Energy efficiency class
KW
Input Power (min-max)AOYG18LAT3
2.70 3.30 3.80 4.80 2.70 3.25 3.71 4.29 3.15 3.51 4.03 3.20 3.71 2.23 2.52 2.83 3.14 2.39 2.69 2.99 2.27 2.57
----
2.70 2.75 2.59 2.51 3.15 2.89 2.77 3.20 3.09 2.23 2.14 1.98 1.83 2.39 2.22 2.06 2.27 2.12
-------------
2.23 2.14 1.98 1.83 2.03 1.89 1.75 2.27 2.12
2.70 ( 1.5 - 3.3 )3.30 ( 1.5 - 4.2 )3.80 ( 1.5 - 4.8 )4.80 ( 1.5 - 5.8 )5.40 ( 2.0 - 6.1 )6.00 ( 2.0 - 6.4 )6.30 ( 2.0 - 6.5 )6.80 ( 2.0 - 7.1 )6.30 ( 2.0 - 6.5 )6.40 ( 2.0 - 6.6 )6.80 ( 2.0 - 7.2 )6.40 ( 2.0 - 6.6 )6.80 ( 2.0 - 7.3 )6.70 ( 2.0 - 7.7 )6.80 ( 2.0 - 7.8 )6.80 ( 2.0 - 7.8 )6.80 ( 2.0 - 8.0 )6.80 ( 2.0 - 7.8 )6.80 ( 2.0 - 7.9 )6.80 ( 2.0 - 8.0 )6.80 ( 2.0 - 7.9 )6.80 ( 2.0 - 7.9 )
0.83 ( 0.43 - 1.00 )1.00 ( 0.42 - 1.30 )1.26 ( 0.42 - 1.62 )1.30 ( 0.42 - 1.70 )1.59 ( 0.52 - 1.93 )1.87 ( 0.52 - 2.06 )1.98 ( 0.52 - 2.06 )1.92 ( 0.50 - 2.06 )1.98 ( 0.52 - 2.06 )1.99 ( 0.52 - 2.06 )1.91 ( 0.50 - 2.06 )1.98 ( 0.52 - 2.06 )1.90 ( 0.50 - 2.06 )1.70 ( 0.50 - 2.06 )1.70 ( 0.50 - 2.06 )1.69 ( 0.50 - 2.06 )1.62 ( 0.50 - 2.06 )1.69 ( 0.50 - 2.06 )1.68 ( 0.50 - 2.06 )1.62 ( 0.50 - 2.06 )1.68 ( 0.50 - 2.06 )1.67 ( 0.50 - 2.06 )
3.25 3.30 3.02 3.69 3.40 3.21 3.18 3.54 3.18 3.22 3.56 3.23 3.58 3.94 4.00 4.02 4.20 4.02 4.05 4.20 4.05 4.07
CCDBBCDBDCBCBAAAAAAAAA
Combination of indoor unit
79
121479
12149
1214121479
12149
12149
12
----7777999
1212777799999
-------------777777799
1Room
2Room
3Room
HEATING OPERATIONHeating Capacity
Room 1KW
Room 2KW
Room 3KW
Total Capacity (min-max)KW
COP Energy efficiency class
KW
Input Power (min-max)AOYG24LAT3
2.70 3.30 3.80 4.80 6.00 2.75 3.30 4.12 4.80 5.39 3.30 4.00 4.68 5.16 3.80 4.31 4.80 2.47 2.86 3.25 3.65 4.09 2.74 3.09 3.52 3.97 2.93 3.31 2.63 2.98 3.37 3.81 2.83 3.17 2.67
-----
2.75 2.80 2.88 2.80 2.51 3.30 3.30 3.22 2.84 3.80 3.59 3.20 2.47 2.42 2.28 2.13 1.91 2.74 2.55 2.42 2.18 2.93 2.76 2.63 2.46 2.32 2.10 2.83 2.64 2.67
-----------------
2.47 2.42 2.28 2.13 1.91 2.32 2.16 2.06 1.85 2.05 1.93 2.63 2.46 2.32 2.10 2.34 2.18 2.67
2.70 ( 1.5 - 3.3 )3.30 ( 1.5 - 4.2 )3.80 ( 1.5 - 4.8 )4.80 ( 1.5 - 5.8 )6.00 ( 1.6 - 7.1 )5.50 ( 2.0 - 6.1 )6.10 ( 2.0 - 7.0 )7.00 ( 2.0 - 7.3 )7.60 ( 2.0 - 8.3 )7.90 ( 2.0 - 8.3 )6.60 ( 2.0 - 7.4 )7.30 ( 2.0 - 7.7 )7.90 ( 2.0 - 8.3 )8.00 ( 2.0 - 8.5 )7.60 ( 2.0 - 7.8 )7.90 ( 2.0 - 8.4 )8.00 ( 2.0 - 8.6 )7.40 ( 2.0 - 8.6 )7.70 ( 2.0 - 8.8 )7.80 ( 2.0 - 8.9 )7.90 ( 2.0 - 9.2 )7.90 ( 2.0 - 9.2 )7.80 ( 2.0 - 9.0 )7.80 ( 2.0 - 9.1 )8.00 ( 2.0 - 9.2 )8.00 ( 2.0 - 9.2 )7.90 ( 2.0 - 9.1 )8.00 ( 2.0 - 9.2 )7.90 ( 2.0 - 9.1 )7.90 ( 2.0 - 9.2 )8.00 ( 2.0 - 9.2 )8.00 ( 2.0 - 9.2 )8.00 ( 2.0 - 9.2 )8.00 ( 2.0 - 9.2 )8.00 ( 2.0 - 9.2 )
0.83 ( 0.43 - 1.00 )1.00 ( 0.42 - 1.30 )1.26 ( 0.42 - 1.62 )1.30 ( 0.42 - 1.70 )1.85 ( 0.42 - 2.40 )1.55 ( 0.52 - 1.93 )1.82 ( 0.52 - 2.52 )2.31 ( 0.52 - 2.66 )2.28 ( 0.50 - 2.87 )2.34 ( 0.50 - 2.87 )2.04 ( 0.52 - 2.68 )2.43 ( 0.52 - 2.87 )2.38 ( 0.50 - 2.87 )2.32 ( 0.50 - 2.87 )2.54 ( 0.52 - 2.87 )2.37 ( 0.50 - 2.87 )2.31 ( 0.50 - 2.87 )2.05 ( 0.50 - 2.68 )2.11 ( 0.50 - 2.87 )2.10 ( 0.50 - 2.80 )2.02 ( 0.50 - 2.72 )2.00 ( 0.50 - 2.70 )2.10 ( 0.50 - 2.87 )2.09 ( 0.50 - 2.87 )2.02 ( 0.50 - 2.72 )2.00 ( 0.50 - 2.69 )2.08 ( 0.50 - 2.87 )2.01 ( 0.50 - 2.70 )2.09 ( 0.50 - 2.87 )2.08 ( 0.50 - 2.87 )2.00 ( 0.50 - 2.70 )1.98 ( 0.50 - 2.68 )2.07 ( 0.50 - 2.80 )2.00 ( 0.50 - 2.69 )2.06 ( 0.50 - 2.78 )
3.25 3.30 3.02 3.69 3.24 3.55 3.35 3.03 3.33 3.38 3.24 3.00 3.32 3.45 2.99 3.33 3.46 3.61 3.65 3.71 3.91 3.95 3.71 3.73 3.96 4.00 3.80 3.98 3.78 3.80 4.00 4.04 3.86 4.00 3.88
CCDBBBCDCCCDCBDCBAAAAAAAAAAAAAAAAAA
Combination of indoor unit
79
12141879
1214189
12141812141879
1214189
12141812149
1214
18*1
121412
-----777779999
121212777779999
12129999
121212
-----------------77777777777999999
12
2 Rooms Multi cooling 2 Rooms Multi heating
3 Rooms Multi cooling 3 Rooms Multi heating
Note: •7:7000Btu/h / 9:9000Btu/h / 12:12000Btu/h models •Operating data under running indoor units are shown on the above table. •2 or more indoor units should be connected. •Cooling capacity is based on 27ºCDB/19ºCWB (indoor temperature), 35ºCDB (outdoor temperature). •Pipe Length: 5m, Height difference: 0m (Outdoor unit to Indoor unit) •The Total ability of connected a indoor unit is up to 24000Btu from 14000Btu.
Note: •7:7000Btu/h / 9:9000Btu/h / 12:12000Btu/h models •Operating data under running indoor units are shown on the above table. •2 or more indoor units should be connected. •Heating capacity is based on 20ºCDB (indoor temperature), 7ºCDB/6ºCWB (outdoor temperature). •Pipe Length: 5m, Height difference: 0m (Outdoor unit to Indoor unit) •The Total ability of connected a indoor unit is up to 24000Btu from 14000Btu.
Note: •7:7000Btu/h / 9:9000Btu/h / 12:12000Btu/h / 14:14000Btu/h / 18:18000Btu/h models •Operating data under running indoor units are shown on the above table. •2 or more indoor units should be connected. •Cooling capacity is based on 27ºCDB/19ºCWB (indoor temperature), 35ºCDB (outdoor temperature). •Pipe Length: 5m, Height difference: 0m (Outdoor unit to Indoor unit) •The Total ability of connected a indoor unit is up to 36000Btu from 14000Btu. *1: When ASYG18L is connected, connect at least 1 wall mounted type for 9000Btu.
Note: •7:7000Btu/h / 9:9000Btu/h / 12:12000Btu/h / 14:14000Btu/h / 18:18000Btu/h models •Operating data under running indoor units are shown on the above table. •2 or more indoor units should be connected. •Heating capacity is based on 20ºCDB (indoor temperature), 7ºCDB/6ºCWB (outdoor temperature). •Pipe Length: 5m, Height difference: 0m (Outdoor unit to Indoor unit) •The Total ability of connected a indoor unit is up to 36000Btu from 14000Btu. *1: When ASYG18L is connected, connect at least 1 wall mounted type for 9000Btu.
083082
Multi Combination Table
79
1214182479
121418249
1214182412141824141824182479
121418249
121418241214182414182418249
1214182412141824141824181214182414181879
1214189
12141812141814189
1214181214181418121418149
1214
18*1
1214
18*2
1412141412
------77777799999
12121212141414181877777799999
12121212141414181899999
121212121414141812121212141418777779999
12121214149999
1212121414121212149999
1212121412121412
--------------------------777777777777777777779999999999999
1212121212121277777777777777999999999
1212121299999999
12121212
------------------------------------------------------------------77777777777777777777777777799999999999
12
2.30 ( 1.6 - 2.7 )2.70 ( 1.6 - 3.4 )3.50 ( 1.6 - 3.8 )4.00 ( 1.7 - 4.5 )5.20 ( 1.7 - 6.0 )6.80 ( 1.8 - 7.4 )4.60 ( 1.8 - 5.2 )5.00 ( 1.8 - 6.0 )5.80 ( 1.8 - 6.2 )6.30 ( 1.8 - 7.1 )6.90 ( 2.8 - 8.2 )7.20 ( 2.8 - 9.3 )5.40 ( 1.8 - 6.4 )6.20 ( 2.8 - 6.8 )6.70 ( 2.8 - 7.8 )7.00 ( 2.8 - 8.7 )7.30 ( 2.8 - 9.5 )6.70 ( 2.8 - 7.3 )6.90 ( 2.8 - 8.5 )7.00 ( 2.8 - 9.1 )7.30 ( 2.8 - 9.5 )7.10 ( 2.8 - 9.0 )7.20 ( 2.8 - 9.3 )7.40 ( 3.4 - 9.7 )7.40 ( 3.4 - 9.7 )7.50 ( 3.4 - 9.9 )6.90 ( 1.8 - 7.5 )7.30 ( 2.8 - 7.7 )7.00 ( 2.8 - 8.2 )7.20 ( 1.6 - 8.9 )7.70 ( 2.8 - 10.0 )7.80 ( 2.8 - 10.1 )7.00 ( 2.8 - 8.3 )7.20 ( 1.6 - 8.9 )7.20 ( 2.8 - 9.1 )7.70 ( 2.8 - 9.9 )7.80 ( 2.8 - 10.1 )7.20 ( 1.6 - 9.1 )7.30 ( 2.8 - 9.2 )7.70 ( 2.8 - 9.9 )7.80 ( 2.8 - 10.1 )7.30 ( 2.8 - 9.3 )7.70 ( 3.5 - 10.0 )7.90 ( 3.5 - 10.1 )7.80 ( 3.5 - 10.1 )7.90 ( 4.7 - 10.1 )7.20 ( 2.8 - 8.9 )7.20 ( 2.8 - 9.1 )7.30 ( 2.8 - 9.2 )7.70 ( 2.8 - 9.9 )7.80 ( 2.8 - 10.1 )7.20 ( 2.8 - 9.1 )7.30 ( 2.8 - 9.2 )7.70 ( 2.8 - 9.9 )7.80 ( 2.8 - 10.1 )7.30 ( 3.5 - 9.3 )7.80 ( 3.5 - 10.0 )7.90 ( 3.5 - 10.1 )7.80 ( 4.7 - 10.1 )7.30 ( 2.8 - 9.2 )7.40 ( 2.8 - 9.3 )7.80 ( 3.5 - 10.0 )7.90 ( 3.5 - 10.1 )7.40 ( 3.5 - 9.4 )7.80 ( 3.5 - 10.1 )7.90 ( 4.7 - 10.1 )7.60 ( 1.6 - 9.6 )7.60 ( 1.6 - 9.8 )7.70 ( 1.6 - 9.9 )7.70 ( 2.8 - 9.9 )8.00 ( 2.8 - 10.1 )7.70 ( 2.8 - 9.7 )7.70 ( 2.8 - 9.9 )7.70 ( 2.8 - 10.0 )8.00 ( 3.5 - 10.1 )7.70 ( 2.8 - 10.0 )7.80 ( 2.8 - 10.0 )8.00 ( 3.5 - 10.1 )8.00 ( 3.5 - 10.1 )8.00 ( 3.5 - 10.1 )7.70 ( 2.8 - 9.9 )7.70 ( 2.8 - 10.0 )7.80 ( 3.5 - 10.1 )8.00 ( 3.5 - 10.1 )7.80 ( 2.8 - 10.0 )7.80 ( 3.5 - 10.1 )8.00 ( 3.5 - 10.1 )7.90 ( 3.5 - 10.1 )8.00 ( 4.7 - 10.1 )7.80 ( 2.8 - 10.1 )7.90 ( 3.5 - 10.1 )8.00 ( 3.5 - 10.1 )7.90 ( 3.5 - 10.1 )7.70 ( 3.5 - 10.0 )7.80 ( 3.5 - 10.0 )7.80 ( 3.5 - 10.1 )8.00 ( 4.7 - 10.1 )7.80 ( 3.5 - 10.1 )7.80 ( 3.5 - 10.1 )8.00 ( 4.7 - 10.1 )7.90 ( 4.7 - 10.1 )7.80 ( 3.5 - 10.1 )7.90 ( 3.5 - 10.1 )7.90 ( 4.7 - 10.1 )8.00 ( 3.5 - 10.1 )
0.78 ( 0.56 - 0.99 )0.94 ( 0.56 - 1.25 )1.24 ( 0.56 - 1.40 )1.40 ( 0.57 - 1.68 )1.68 ( 0.56 - 2.20 )2.40 ( 0.56 - 2.86 )1.42 ( 0.60 - 1.62 )1.60 ( 0.60 - 2.16 )2.00 ( 0.60 - 2.20 )2.15 ( 0.60 - 2.50 )2.10 ( 0.90 - 2.85 )2.16 ( 0.90 - 3.58 )1.68 ( 0.60 - 2.23 )2.16 ( 0.90 - 2.50 )2.35 ( 0.90 - 2.90 )2.15 ( 0.90 - 3.25 )2.15 ( 0.90 - 3.52 )2.36 ( 0.90 - 2.80 )2.18 ( 0.90 - 3.30 )2.15 ( 0.90 - 3.52 )2.15 ( 0.90 - 3.52 )2.20 ( 0.90 - 3.40 )2.20 ( 0.90 - 3.52 )2.20 ( 1.10 - 3.52 )2.20 ( 1.10 - 3.52 )2.20 ( 1.10 - 3.52 )2.20 ( 0.60 - 2.44 )2.35 ( 0.90 - 2.55 )2.17 ( 0.90 - 2.90 )2.22 ( 0.68 - 3.43 )2.22 ( 0.98 - 3.55 )2.19 ( 0.98 - 3.53 )2.17 ( 0.90 - 2.90 )2.22 ( 0.68 - 3.41 )2.22 ( 0.98 - 3.56 )2.22 ( 0.98 - 3.56 )2.19 ( 0.98 - 3.53 )2.22 ( 0.68 - 3.54 )2.22 ( 0.98 - 3.56 )2.22 ( 0.98 - 3.56 )2.19 ( 0.98 - 3.56 )2.22 ( 0.98 - 3.58 )2.22 ( 1.17 - 3.58 )2.20 ( 1.17 - 3.58 )2.22 ( 1.17 - 3.58 )2.22 ( 1.27 - 3.58 )2.22 ( 0.98 - 3.42 )2.22 ( 0.98 - 3.54 )2.22 ( 0.98 - 3.57 )2.22 ( 0.98 - 3.56 )2.20 ( 1.17 - 3.54 )2.22 ( 0.98 - 3.54 )2.22 ( 0.98 - 3.57 )2.22 ( 0.98 - 3.56 )2.19 ( 0.98 - 3.56 )2.22 ( 1.17 - 3.58 )2.22 ( 1.17 - 3.58 )2.22 ( 1.27 - 3.56 )2.22 ( 1.27 - 3.58 )2.22 ( 0.98 - 3.55 )2.22 ( 0.98 - 3.58 )2.22 ( 1.17 - 3.57 )2.20 ( 1.17 - 3.54 )2.22 ( 1.17 - 3.58 )2.22 ( 1.17 - 3.58 )2.22 ( 1.27 - 3.58 )2.20 ( 0.68 - 3.41 )2.22 ( 0.68 - 3.54 )2.22 ( 0.68 - 3.54 )2.22 ( 0.98 - 3.56 )2.20 ( 0.98 - 3.55 )2.22 ( 0.98 - 3.42 )2.22 ( 0.98 - 3.55 )2.22 ( 0.98 - 3.57 )2.20 ( 1.17 - 3.55 )2.22 ( 0.98 - 3.55 )2.22 ( 0.98 - 3.57 )2.20 ( 1.17 - 3.56 )2.22 ( 1.17 - 3.58 )2.22 ( 1.17 - 3.58 )2.22 ( 0.98 - 3.56 )2.22 ( 0.98 - 3.56 )2.22 ( 1.17 - 3.58 )2.22 ( 1.17 - 3.56 )2.22 ( 0.98 - 3.56 )2.22 ( 1.17 - 3.58 )2.22 ( 1.17 - 3.56 )2.22 ( 1.17 - 3.58 )2.22 ( 1.27 - 3.57 )2.22 ( 0.98 - 3.56 )2.22 ( 1.17 - 3.58 )2.22 ( 1.17 - 3.56 )2.22 ( 1.17 - 3.58 )2.22 ( 1.17 - 3.56 )2.22 ( 1.17 - 3.57 )2.22 ( 1.17 - 3.58 )2.22 ( 1.27 - 3.58 )2.22 ( 1.17 - 3.58 )2.22 ( 1.17 - 3.58 )2.22 ( 1.27 - 3.58 )2.22 ( 1.27 - 3.58 )2.22 ( 1.17 - 3.58 )2.22 ( 1.17 - 3.58 )2.22 ( 1.27 - 3.58 )2.22 ( 1.17 - 3.58 )
2.95 2.87 2.82 2.86 3.10 2.83 3.24 3.13 2.90 2.93 3.29 3.33 3.21 2.87 2.85 3.26 3.40 2.84 3.17 3.26 3.40 3.23 3.27 3.36 3.36 3.41 3.14 3.11 3.23 3.24 3.47 3.56 3.23 3.24 3.24 3.47 3.56 3.24 3.29 3.47 3.56 3.29 3.47 3.59 3.51 3.56 3.24 3.24 3.29 3.47 3.55 3.24 3.29 3.47 3.56 3.29 3.51 3.56 3.51 3.29 3.33 3.51 3.59 3.33 3.51 3.56 3.45 3.42 3.47 3.47 3.64 3.47 3.47 3.47 3.64 3.47 3.51 3.64 3.60 3.60 3.47 3.47 3.51 3.60 3.51 3.51 3.60 3.56 3.60 3.51 3.56 3.60 3.56 3.47 3.51 3.51 3.60 3.51 3.51 3.60 3.56 3.51 3.56 3.56 3.60
CCCCBCABCCAAACCAACBAAAAAAABBAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA
1Room
2Room
3Room
4Room
COOLING OPERATIONCooling Capacity
2.30 2.70 3.50 4.00 5.20 6.80 2.30 2.70 3.50 4.00 4.80 5.40 2.70 3.50 4.00 4.60 5.23 3.35 3.68 4.18 4.82 3.55 4.07 4.66 3.70 4.25 2.30 2.70 3.02 3.27 4.08 4.57 2.45 2.78 3.16 3.96 4.46 2.62 3.04 3.78 4.28 2.81 3.52 4.07 3.19 3.68 2.40 2.68 3.11 3.85 4.35 2.53 2.95 3.68 4.18 2.73 3.48 3.98 3.12 2.43 2.85 3.57 4.07 2.64 3.34 3.05 1.90 2.07 2.37 2.75 3.43 2.04 2.30 2.68 3.35 2.20 2.60 3.22 2.50 3.04 1.98 2.24 2.64 3.27 2.17 2.54 3.15 2.41 2.98 2.08 2.47 3.04 2.32 1.93 2.21 2.58 3.20 2.12 2.48 3.09 2.36 2.03 2.41 2.27 2.00
Room 1KW
------
2.30 2.30 2.30 2.30 2.10 1.80 2.70 2.70 2.70 2.40 2.07 3.35 3.22 2.82 2.48 3.55 3.13 2.74 3.70 3.25 2.30 2.30 1.99 1.96 1.81 1.61 2.45 2.34 2.14 1.98 1.77 2.62 2.43 2.24 2.01 2.81 2.61 2.39 3.19 2.92 2.40 2.26 2.10 1.93 1.73 2.53 2.36 2.18 1.97 2.73 2.58 2.34 3.12 2.43 2.28 2.12 1.92 2.64 2.48 3.05 1.90 1.84 1.78 1.65 1.52 2.04 1.94 1.81 1.67 2.20 2.08 1.91 2.50 2.25 1.98 1.89 1.78 1.64 2.17 2.03 1.87 2.41 2.21 2.08 1.98 1.80 2.32 1.93 1.86 1.74 1.60 2.12 1.98 1.83 2.36 2.03 1.93 2.27 2.00
Room 2KW
------------------------------------------------------------------
1.90 1.84 1.78 1.65 1.52 1.81 1.73 1.61 1.49 1.65 1.56 1.43 1.50 1.35 1.76 1.68 1.59 1.45 1.63 1.52 1.40 1.45 1.32 1.56 1.48 1.35 1.39 1.93 1.86 1.74 1.60 1.78 1.67 1.54 1.59 1.71 1.63 1.53 2.00
Room 4KW
--------------------------
2.30 2.30 1.99 1.96 1.81 1.61 2.09 2.08 1.90 1.76 1.57 1.96 1.83 1.68 1.51 1.68 1.57 1.44 1.42 1.30 2.40 2.26 2.10 1.93 1.73 2.14 1.99 1.84 1.66 1.84 1.74 1.58 1.56 2.43 2.28 2.12 1.92 2.11 1.98 1.81 1.90 1.84 1.78 1.65 1.52 1.81 1.73 1.61 1.49 1.65 1.56 1.43 1.50 1.35 1.98 1.89 1.78 1.64 1.83 1.71 1.58 1.63 1.49 2.08 1.98 1.80 1.86 1.93 1.86 1.74 1.60 1.78 1.67 1.54 1.59 2.03 1.93 1.82 2.00
Room 3KW
Total Capacity (min-max)KW
EER Energy efficiency class
KW
Input Power (min-max)AOYG30LAT4
2.70 ( 1.5 - 3.3 )3.30 ( 1.5 - 3.7 )3.80 ( 1.5 - 4.5 )4.80 ( 1.7 - 5.8 )6.00 ( 3.2 - 7.1 )8.20 ( 3.2 - 9.0 )5.40 ( 1.7 - 5.9 )6.00 ( 1.7 - 7.2 )6.50 ( 1.7 - 7.2 )7.50 ( 3.3 - 8.7 )8.70 ( 3.3 - 9.4 )9.50 ( 3.3 - 10.7 )6.60 ( 3.3 - 7.4 )7.10 ( 1.7 - 8.3 )8.10 ( 3.3 - 9.3 )9.10 ( 3.3 - 10.1 )9.50 ( 3.3 - 11.0 )7.60 ( 3.3 - 8.8 )8.60 ( 3.3 - 9.8 )9.30 ( 3.3 - 10.3 )9.60 ( 3.3 - 11.0 )9.40 ( 3.3 - 10.3 )9.60 ( 3.3 - 11.1 )9.60 ( 4.3 - 11.5 )9.60 ( 4.3 - 11.5 )9.60 ( 4.3 - 11.6 )8.10 ( 1.8 - 8.8 )8.70 ( 3.3 - 9.3 )9.20 ( 3.3 - 9.7 )9.00 ( 1.8 - 10.1 )9.40 ( 3.3 - 11.2 )9.50 ( 3.3 - 11.5 )9.30 ( 3.3 - 9.7 )9.00 ( 1.8 - 10.0 )9.10 ( 3.3 - 10.2 )9.40 ( 3.3 - 11.3 )9.60 ( 3.3 - 11.5 )9.00 ( 1.8 - 10.1 )9.20 ( 3.3 - 10.3 )9.50 ( 3.3 - 11.4 )9.60 ( 3.3 - 11.7 )9.30 ( 3.3 - 10.6 )9.50 ( 3.7 - 11.5 )9.60 ( 3.3 - 11.7 )9.60 ( 3.7 - 12.0 )9.60 ( 4.3 - 12.0 )9.00 ( 3.3 - 10.0 )9.00 ( 3.3 - 10.1 )9.20 ( 3.3 - 10.3 )9.50 ( 3.7 - 11.4 )9.60 ( 3.7 - 11.7 )9.10 ( 3.3 - 10.3 )9.30 ( 3.3 - 10.5 )9.50 ( 3.7 - 11.4 )9.60 ( 3.7 - 11.8 )9.30 ( 3.7 - 10.7 )9.50 ( 3.7 - 11.6 )9.60 ( 4.3 - 11.9 )9.60 ( 4.3 - 12.0 )9.20 ( 3.3 - 10.3 )9.30 ( 3.3 - 10.6 )9.50 ( 3.7 - 11.6 )9.60 ( 3.7 - 11.8 )9.40 ( 3.7 - 10.8 )9.50 ( 3.7 - 11.6 )9.60 ( 4.3 - 12.0 )9.40 ( 1.8 - 10.8 )9.50 ( 1.8 - 10.9 )9.50 ( 1.8 - 11.1 )9.60 ( 3.3 - 11.3 )9.60 ( 3.3 - 12.0 )9.50 ( 3.3 - 10.9 )9.50 ( 3.3 - 11.1 )9.60 ( 3.3 - 11.4 )9.60 ( 3.7 - 12.0 )9.60 ( 3.3 - 11.3 )9.60 ( 3.3 - 11.5 )9.60 ( 3.7 - 12.0 )9.60 ( 3.7 - 11.8 )9.60 ( 3.7 - 12.0 )9.50 ( 3.3 - 11.2 )9.60 ( 3.3 - 11.3 )9.60 ( 3.7 - 11.5 )9.60 ( 3.7 - 12.0 )9.60 ( 3.3 - 11.4 )9.60 ( 3.7 - 11.6 )9.60 ( 3.7 - 12.0 )9.60 ( 3.7 - 11.8 )9.60 ( 4.3 - 12.0 )9.60 ( 3.3 - 11.5 )9.60 ( 3.7 - 11.7 )9.60 ( 3.7 - 12.0 )9.60 ( 3.7 - 11.9 )9.60 ( 3.7 - 11.3 )9.60 ( 3.7 - 11.4 )9.60 ( 3.7 - 11.6 )9.60 ( 4.3 - 12.0 )9.60 ( 3.7 - 11.5 )9.60 ( 3.7 - 11.7 )9.60 ( 4.3 - 12.0 )9.60 ( 4.3 - 11.9 )9.60 ( 3.7 - 11.6 )9.60 ( 3.7 - 11.8 )9.60 ( 4.3 - 11.9 )9.60 ( 3.7 - 11.6 )
1.00 ( 0.55 - 1.25 )1.22 ( 0.55 - 1.41 )1.40 ( 0.55 - 1.80 )1.48 ( 0.58 - 1.90 )1.90 ( 0.90 - 2.46 )2.78 ( 0.90 - 3.33 )1.58 ( 0.55 - 1.80 )1.76 ( 0.55 - 2.50 )2.20 ( 0.55 - 2.45 )2.25 ( 0.90 - 2.88 )2.67 ( 0.90 - 3.00 )2.70 ( 0.90 - 3.50 )2.02 ( 0.90 - 2.50 )2.35 ( 0.55 - 3.08 )2.67 ( 0.90 - 3.30 )2.67 ( 0.90 - 3.40 )2.67 ( 0.90 - 3.50 )2.65 ( 0.90 - 3.30 )3.06 ( 0.90 - 3.50 )2.90 ( 0.90 - 3.50 )2.68 ( 0.90 - 3.50 )2.93 ( 0.90 - 3.50 )2.77 ( 0.90 - 3.50 )2.65 ( 1.02 - 3.50 )2.65 ( 1.02 - 3.50 )2.65 ( 1.02 - 3.50 )2.30 ( 0.55 - 2.65 )2.60 ( 0.90 - 2.85 )2.83 ( 0.90 - 3.10 )2.66 ( 0.58 - 3.53 )2.46 ( 0.87 - 3.52 )2.47 ( 0.87 - 3.52 )2.80 ( 0.90 - 3.10 )2.69 ( 0.58 - 3.51 )2.64 ( 0.87 - 3.50 )2.45 ( 0.87 - 3.50 )2.46 ( 0.87 - 3.51 )2.66 ( 0.58 - 3.48 )2.62 ( 0.87 - 3.48 )2.44 ( 0.87 - 3.47 )2.45 ( 0.87 - 3.56 )2.59 ( 0.87 - 3.48 )2.42 ( 0.97 - 3.52 )2.45 ( 0.87 - 3.56 )2.40 ( 0.97 - 3.52 )2.40 ( 1.12 - 3.52 )2.69 ( 0.87 - 3.51 )2.67 ( 0.87 - 3.48 )2.63 ( 0.87 - 3.48 )2.44 ( 0.97 - 3.48 )2.45 ( 0.97 - 3.57 )2.65 ( 0.87 - 3.52 )2.61 ( 0.87 - 3.52 )2.43 ( 0.97 - 3.47 )2.44 ( 0.97 - 3.55 )2.58 ( 0.97 - 3.46 )2.41 ( 0.97 - 3.51 )2.42 ( 1.12 - 3.57 )2.40 ( 1.12 - 3.52 )2.63 ( 0.87 - 3.49 )2.59 ( 0.87 - 3.49 )2.42 ( 0.97 - 3.52 )2.43 ( 0.97 - 3.54 )2.40 ( 0.97 - 3.50 )2.40 ( 0.97 - 3.49 )2.40 ( 1.12 - 3.52 )2.58 ( 0.58 - 3.47 )2.57 ( 0.58 - 3.51 )2.56 ( 0.58 - 3.55 )2.53 ( 0.87 - 3.56 )2.40 ( 0.87 - 3.56 )2.56 ( 0.87 - 3.44 )2.55 ( 0.87 - 3.54 )2.53 ( 0.87 - 3.54 )2.40 ( 0.97 - 3.55 )2.54 ( 0.87 - 3.57 )2.51 ( 0.87 - 3.58 )2.40 ( 0.97 - 3.58 )2.49 ( 0.97 - 3.58 )2.40 ( 0.97 - 3.56 )2.55 ( 0.87 - 3.54 )2.54 ( 0.87 - 3.58 )2.52 ( 0.97 - 3.58 )2.40 ( 0.97 - 3.58 )2.53 ( 0.87 - 3.58 )2.50 ( 0.97 - 3.58 )2.40 ( 0.97 - 3.58 )2.48 ( 0.97 - 3.58 )2.40 ( 1.12 - 3.58 )2.52 ( 0.87 - 3.58 )2.49 ( 0.97 - 3.58 )2.40 ( 0.97 - 3.56 )2.47 ( 0.97 - 3.58 )2.55 ( 0.97 - 3.58 )2.53 ( 0.97 - 3.58 )2.51 ( 0.97 - 3.58 )2.40 ( 1.12 - 3.58 )2.52 ( 0.97 - 3.58 )2.50 ( 0.97 - 3.58 )2.40 ( 1.12 - 3.58 )2.48 ( 1.12 - 3.58 )2.51 ( 0.97 - 3.58 )2.49 ( 0.97 - 3.58 )2.46 ( 1.12 - 3.58 )2.50 ( 0.97 - 3.58 )
2.70 2.70 2.71 3.24 3.16 2.95 3.42 3.41 2.95 3.33 3.26 3.52 3.27 3.02 3.03 3.41 3.56 2.87 2.81 3.21 3.58 3.21 3.47 3.62 3.62 3.62 3.52 3.35 3.25 3.38 3.82 3.85 3.32 3.35 3.45 3.84 3.90 3.38 3.51 3.89 3.92 3.59 3.93 3.92 4.00 4.00 3.35 3.37 3.50 3.89 3.92 3.43 3.56 3.91 3.93 3.60 3.94 3.97 4.00 3.50 3.59 3.93 3.95 3.92 3.96 4.00 3.64 3.70 3.71 3.79 4.00 3.71 3.73 3.79 4.00 3.78 3.82 4.00 3.86 4.00 3.73 3.78 3.81 4.00 3.79 3.84 4.00 3.87 4.00 3.81 3.85 4.00 3.89 3.76 3.79 3.82 4.00 3.81 3.84 4.00 3.87 3.82 3.86 3.90 3.84
EEECDDBBDCCBCDDBBDDCBCBAAABCCCAACCBAACBAABAAAACCBAABBAABAAABBAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA
1Room
2Room
3Room
4Room
HEATING OPERATIONHeating Capacity
Total Capacity (min-max)KW
COP Energy efficiency class
KW
Input Power (min-max)AOYG30LAT4
2.70 3.30 3.80 4.80 6.00 8.20 2.70 3.30 3.80 4.80 6.00 7.15 3.30 3.80 4.80 5.87 6.77 3.80 4.80 5.69 6.56 4.70 5.33 6.06 4.80 5.54 2.70 3.30 3.80 4.15 4.86 5.44 3.30 3.56 4.00 4.66 5.29 3.33 3.80 4.45 5.03 3.60 4.19 4.77 3.89 4.42 3.00 3.39 3.87 4.52 5.11 3.22 3.69 4.29 4.86 3.46 4.04 4.62 3.76 3.07 3.49 4.07 4.65 3.32 3.85 3.60 2.35 2.68 3.06 3.49 4.00 2.57 2.95 3.36 3.87 2.82 3.20 3.69 3.03 3.51 2.47 2.87 3.25 3.74 2.72 3.09 3.58 2.94 3.41 2.59 2.95 3.43 2.81 2.40 2.76 3.14 3.62 2.63 2.99 3.47 2.84 2.51 2.87 2.73 2.40
Room 1KW
------
2.70 2.70 2.70 2.70 2.70 2.35 3.30 3.30 3.30 3.23 2.73 3.80 3.80 3.61 3.04 4.70 4.27 3.54 4.80 4.06 2.70 2.70 2.70 2.42 2.27 2.03 3.30 2.94 2.75 2.56 2.33 3.33 3.17 2.97 2.69 3.60 3.35 3.05 3.89 3.53 3.00 2.80 2.66 2.49 2.25 3.22 3.07 2.86 2.59 3.46 3.23 2.95 3.76 3.07 2.91 2.71 2.48 3.32 3.08 3.60 2.35 2.27 2.14 2.04 1.87 2.57 2.43 2.31 2.13 2.82 2.67 2.46 3.03 2.81 2.47 2.36 2.23 2.06 2.72 2.58 2.39 2.94 2.73 2.59 2.46 2.29 2.81 2.40 2.28 2.16 1.99 2.63 2.49 2.31 2.84 2.51 2.39 2.73 2.40
Room 2KW
------------------------------------------------------------------
2.35 2.27 2.14 2.04 1.87 2.18 2.06 1.96 1.80 1.98 1.87 1.72 1.77 1.64 2.09 2.01 1.89 1.75 1.91 1.80 1.67 1.71 1.59 1.81 1.72 1.60 1.64 2.40 2.28 2.16 1.99 2.17 2.06 1.91 1.96 2.07 1.97 1.87 2.40
Room 4KW
--------------------------
2.70 2.70 2.70 2.42 2.27 2.03 2.70 2.49 2.33 2.17 1.98 2.33 2.22 2.08 1.88 2.10 1.96 1.78 1.82 1.65 3.00 2.80 2.66 2.49 2.25 2.65 2.53 2.36 2.14 2.38 2.22 2.03 2.07 3.07 2.91 2.71 2.48 2.76 2.57 2.40 2.35 2.27 2.14 2.04 1.87 2.18 2.06 1.96 1.80 1.98 1.87 1.72 1.77 1.64 2.47 2.36 2.23 2.06 2.25 2.13 1.97 2.02 1.87 2.59 2.46 2.29 2.34 2.40 2.28 2.16 1.99 2.17 2.06 1.91 1.96 2.51 2.39 2.27 2.40
Room 3KW
Combination of indoor unit
Combination of indoor unit
79
1214182479
121418249
1214182412141824141824182479
121418249
121418241214182414182418249
1214182412141824141824181214182414181879
1214189
12141812141814189
1214181214181418121418149
1214
18*1
1214
18*2
1412141412
------77777799999
12121212141414181877777799999
12121212141414181899999
121212121414141812121212141418777779999
12121214149999
1212121414121212149999
1212121412121412
--------------------------777777777777777777779999999999999
1212121212121277777777777777999999999
1212121299999999
12121212
------------------------------------------------------------------77777777777777777777777777799999999999
12
4 Rooms Multi cooling 4 Rooms Multi heating
Note: •7:7000Btu/h / 9:9000Btu/h / 12:12000Btu/h / 14:14000Btu/h / 18:18000Btu/h / 24:24000Btu/h models •Operating data under running indoor units are shown on the above table. •3 or more indoor units should be connected. •Cooling capacity is based on 27ºCDB/19ºCWB (indoor temperature), 35ºCDB (outdoor temperature). •Pipe Length: 5m, Height difference: 0m (Outdoor unit to Indoor unit) •The Total ability of connected a indoor unit is up to 49000Btu from 27000Btu. *1: Connection of ASYG18L + ARYG09L + ARYG09L + ARYG09L is not available. All types other than this combination can be connected. *2: Connection of ASYG18L + ARYG12L + ARYG09L + ARYG09L is not available. All types other than this combination can be connected.
Note: •7:7000Btu/h / 9:9000Btu/h / 12:12000Btu/h / 14:14000Btu/h / 18:18000Btu/h / 24:24000Btu/h models •Operating data under running indoor units are shown on the above table. •3 or more indoor units should be connected. •Heating capacity is based on 20ºCDB (indoor temperature), 7ºCDB/6ºCWB (outdoor temperature). •Pipe Length: 5m, Height difference: 0m (Outdoor unit to Indoor unit) •The Total ability of connected a indoor unit is up to 49000Btu from 27000Btu. *1: Connection of ASYG18L + ARYG09L + ARYG09L + ARYG09L is not available. All types other than this combination can be connected. *2: Connection of ASYG18L + ARYG12L + ARYG09L + ARYG09L is not available. All types other than this combination can be connected.
085084
Multi Combination Table
3Room
2Room
4Room
COOLING OPERATIONCooling Capacity
Room 1KW
Room 2KW
Room 4KW
Room 5KW
Room 6KW
Room 7KW
Room 8KW
Room 3KW
TotalKW KW
Input powerAOYG45LAT8 Combination of indoor unit
241818181414141414141212121212121212999999997777777
14141212121212121212121212999999999999999999999999977777777777777777777777777777
242418182418181414142418181414141212241818141412129
2418181414129
141414141412121212121212121414141412121212121212129999999999999
1814141414121212121212121212999999999997777
--
24182424182418142424182418142418242418241824182424241824182424141418141418141414121212121814141418141414121212121818141414121212129999
18181414141818141414121212121818141412121212999
24181814
---------------------------------
18141818141824181424181412182418141824181424181412241824181424181412241814121818241814241824181424181412241824182418141224181424241824
----------------------------------------------------------------------------------------------------
----------------------------------------------------------------------------------------------------
----------------------------------------------------------------------------------------------------
----------------------------------------------------------------------------------------------------
5.20 4.24 5.89 5.90 5.87 5.90 5.50 5.79 4.89 4.24 5.89 5.90 5.20 5.50 4.57 3.91 5.20 4.24 5.90 5.65 4.73 5.05 4.08 4.73 3.74 4.24 5.90 5.35 4.41 4.73 3.74 4.41 3.91 5.89 5.90 5.87 5.90 5.90 5.89 5.87 5.90 5.79 5.89 5.90 5.50 5.20 5.89 5.88 5.90 5.65 5.90 5.89 5.90 5.35 5.90 5.65 5.05 4.73 5.89 5.90 5.90 5.50 4.89 5.90 5.20 4.57 4.24 5.65 4.73 4.08 3.74 5.88 5.90 5.89 5.90 5.35 5.88 5.90 5.90 5.65 5.05 5.90 5.35 4.73 4.41 5.90 5.79 5.90 5.20 5.79 4.89 4.24 3.91 5.35 4.41 3.74 5.87 5.90 5.50 5.79
Note: •Cooling capacity is based on 27°CDB/19°CWB(indoor temperature),35°CDB(outdoor temperature) •Pipe Length: 5m (Outdoor unit to Branch box), 3m (Branch box to Indoor unit) •Height difference: 0m (Outdoor unit to Indoor unit) •The values in this table should be used only as a guide. These values are calculated at standard conditions. When you select models finally, select them according to “Model Selection” in the D&T manual
Note: •Cooling capacity is based on 27°CDB/19°CWB(indoor temperature),35°CDB(outdoor temperature) •Pipe Length: 5m (Outdoor unit to Branch box), 3m (Branch box to Indoor unit) •Height difference: 0m (Outdoor unit to Indoor unit) •The values in this table should be used only as a guide. These values are calculated at standard conditions. When you select models finally, select them according to “Model Selection” in the D&T manual
7.03 5.27 4.63 5.01 3.54 3.84 4.10 4.10 4.10 4.10 3.09 3.35 3.52 3.52 3.52 3.52 3.52 3.52 2.46 2.64 2.64 2.64 2.64 2.64 2.64 2.64 1.93 2.05 2.05 2.05 2.05 2.05 2.05 3.60 3.84 3.04 3.15 3.35 3.09 3.04 3.30 3.52 3.09 3.35 3.52 3.52 2.34 2.30 2.49 2.64 2.46 2.34 2.53 2.64 2.46 2.64 2.64 2.64 2.32 2.51 2.47 2.64 2.64 2.51 2.64 2.64 2.64 2.64 2.64 2.64 2.64 1.79 1.91 1.82 1.96 2.05 1.79 1.93 1.91 2.05 2.05 1.93 2.05 2.05 2.05 1.84 2.05 1.95 2.05 2.05 2.05 2.05 2.05 2.05 2.05 2.05 1.77 1.92 2.05 2.05
7.03 7.03 4.63 5.01 6.07 4.94 5.27 4.10 4.10 4.10 6.18 5.01 5.27 4.10 4.10 4.10 3.52 3.52 6.54 5.27 5.27 4.10 4.10 3.52 3.52 2.64 6.64 5.27 5.27 4.10 4.10 3.52 2.64 3.60 3.84 3.54 3.67 3.90 3.09 3.04 3.30 3.52 3.09 3.35 3.52 3.52 3.64 3.57 3.87 4.10 3.28 3.12 3.37 3.52 3.28 3.52 3.52 3.52 2.32 2.51 2.47 2.64 2.64 2.51 2.64 2.64 2.64 2.64 2.64 2.64 2.64 4.59 3.82 3.64 3.93 4.10 3.07 3.32 3.28 3.52 3.52 3.32 3.52 3.52 3.52 2.36 2.64 2.51 2.64 2.64 2.64 2.64 2.64 2.64 2.64 2.64 1.77 1.92 2.05 2.05
---------------------------------
4.63 3.84 4.55 4.72 3.90 4.63 6.07 4.94 4.10 6.18 5.01 4.10 3.52 4.67 6.12 4.97 4.10 4.90 6.23 5.05 4.10 6.54 5.27 4.10 3.52 6.18 5.01 6.59 5.27 4.10 6.68 5.27 4.10 3.52 7.03 5.27 4.10 3.52 4.59 4.91 6.24 5.05 4.10 6.12 4.97 6.54 5.27 4.10 6.63 5.27 4.10 3.52 6.29 5.27 6.68 5.27 7.03 5.27 4.10 3.52 7.03 5.27 4.10 6.07 6.59 5.27 7.03
----------------------------------------------------------------------------------------------------
----------------------------------------------------------------------------------------------------
----------------------------------------------------------------------------------------------------
----------------------------------------------------------------------------------------------------
--
6.18 5.01 6.07 6.59 5.27 7.03 5.27 4.10 6.18 6.68 5.27 7.03 5.27 4.10 7.03 5.27 6.54 7.03 5.27 7.03 5.27 7.03 5.27 7.03 6.64 7.03 5.27 7.03 5.27 7.03 7.03 3.60 3.84 4.55 3.67 3.90 4.63 3.54 3.84 4.10 3.09 3.35 3.52 3.52 4.67 3.57 3.87 4.10 4.90 3.64 3.93 4.10 3.28 3.52 3.52 3.52 4.63 5.01 3.84 4.10 4.10 3.35 3.52 3.52 3.52 2.64 2.64 2.64 2.64 4.59 4.91 3.64 3.93 4.10 4.59 4.97 3.82 4.10 4.10 3.32 3.52 3.52 3.52 4.72 5.27 3.90 4.10 3.52 3.52 3.52 3.52 2.64 2.64 2.64 6.07 4.94 5.27 4.10
14.06 12.30 15.45 15.03 15.68 15.37 14.64 15.23 13.47 12.30 15.45 15.04 14.06 14.65 12.89 11.72 14.07 12.31 15.54 14.94 13.18 13.77 12.01 13.19 11.43 12.31 15.21 14.35 12.59 13.18 11.42 12.60 11.72 15.45 15.37 15.68 15.21 15.04 15.45 15.69 15.38 15.24 15.45 15.05 14.66 14.08 15.33 15.57 15.21 14.94 15.54 15.33 14.87 14.36 15.55 14.95 13.78 13.20 15.45 15.04 15.38 14.65 13.48 15.05 14.07 12.90 12.32 14.95 13.19 12.02 11.44 15.56 15.54 15.33 14.87 14.35 15.57 15.21 15.54 14.94 13.77 15.21 14.36 13.19 12.61 15.21 15.23 15.04 14.06 15.24 13.48 12.31 11.73 14.36 12.60 11.43 15.68 15.37 14.64 15.23
8 Rooms Multi cooling 8 Rooms Multi cooling
4Room
5Room
6Room
COOLING OPERATIONCooling Capacity
Room 1KW
Room 2KW
Room 4KW
Room 5KW
Room 6KW
Room 7KW
Room 8KW
Room 3KW
TotalKW KW
Input powerAOYG45LAT8 Combination of indoor unit
777777777
121299999999999999999997777777777777777777777777777777777777777777777777777777777777799999777
777777777
12121212129999999999999999
121212121299999999999999999997777777777777777777777777777777777777799999999
14141212129977
12121212121412121212129999999999
141212121214141212121212999999999999
141412121212121299999999999997777777777777777799999999
1814241814241824181212141212141414121212141412121299999
1414121212141414141212121814141212121299999
1414181414121212181414141212121299999
181414141212121299999777799999
1299
---------
14121414121418141814121814181412241814129
14141814121814181418141218181424181412241814129
18141818142414121824181424181412241814129
1824181424181412241814129
241814121212999
121212
--------------------------------------------------------------------------------------------
141214129
121412
----------------------------------------------------------------------------------------------------
----------------------------------------------------------------------------------------------------
4.89 4.24 5.50 4.57 3.91 5.05 4.08 4.73 3.74 5.87 5.89 5.88 5.89 5.90 5.89 5.87 5.90 5.89 5.90 5.90 5.89 5.90 5.90 5.90 5.65 5.89 5.90 5.50 5.20 4.73 5.88 5.89 5.88 5.90 5.90 5.87 5.90 5.89 5.90 5.90 5.90 5.79 5.88 5.90 5.90 5.88 5.90 5.65 5.35 5.90 5.79 5.20 4.89 4.41 5.89 5.90 5.87 5.90 5.90 5.87 5.79 5.50 5.89 5.88 5.90 5.65 5.89 5.90 5.35 5.05 5.90 5.50 4.89 4.57 4.08 5.90 5.89 5.90 5.35 5.90 5.65 5.05 4.73 5.90 5.20 4.57 4.24 3.74 5.79 4.89 4.24 3.91 5.87 5.89 5.89 5.90 5.90 5.88 5.89 5.90
2.05 2.05 2.05 2.05 2.05 2.05 2.05 2.05 2.05 3.04 3.09 2.30 2.34 2.46 2.32 2.28 2.36 2.32 2.47 2.51 2.34 2.49 2.46 2.53 2.64 2.32 2.51 2.64 2.64 2.64 1.79 1.82 1.79 1.91 1.93 1.77 1.84 1.80 1.92 1.83 1.95 2.05 1.79 1.91 1.96 1.79 1.93 2.05 2.05 1.83 2.05 2.05 2.05 2.05 1.80 1.92 1.77 1.84 1.95 1.77 2.05 2.05 1.82 1.79 1.93 2.05 1.82 1.96 2.05 2.05 1.92 2.05 2.05 2.05 2.05 1.91 1.82 1.96 2.05 1.91 2.05 2.05 2.05 1.95 2.05 2.05 2.05 2.05 2.05 2.05 2.05 2.05 2.28 2.32 2.34 2.46 2.51 1.78 1.80 1.83
2.05 2.05 2.05 2.05 2.05 2.05 2.05 2.05 2.05 3.04 3.09 3.07 3.12 3.27 2.32 2.28 2.36 2.32 2.47 2.51 2.34 2.49 2.46 2.53 2.64 2.32 2.51 2.64 2.64 2.64 3.07 3.12 3.07 3.28 3.32 2.28 2.36 2.32 2.47 2.36 2.51 2.64 2.30 2.46 2.53 2.30 2.49 2.64 2.64 2.36 2.64 2.64 2.64 2.64 1.80 1.92 1.77 1.84 1.95 1.77 2.05 2.05 1.82 1.79 1.93 2.05 1.82 1.96 2.05 2.05 1.92 2.05 2.05 2.05 2.05 1.91 1.82 1.96 2.05 1.91 2.05 2.05 2.05 1.95 2.05 2.05 2.05 2.05 2.05 2.05 2.05 2.05 2.28 2.32 2.34 2.46 2.51 2.30 2.32 2.36
5.27 4.10 7.03 5.27 4.10 7.03 5.27 7.03 5.27 3.04 3.09 3.57 3.12 3.27 3.60 3.54 3.67 3.09 3.30 3.34 3.64 3.87 3.28 3.37 3.52 2.32 2.51 2.64 2.64 2.64 3.57 3.64 3.07 3.28 3.32 3.54 3.67 3.60 3.84 3.15 3.35 3.52 4.59 3.82 3.93 3.07 3.32 3.52 3.52 2.36 2.64 2.64 2.64 2.64 3.60 3.84 4.55 3.67 3.90 3.04 3.52 3.52 4.67 3.57 3.87 4.10 3.12 3.37 3.52 3.52 2.47 2.64 2.64 2.64 2.64 4.91 3.64 3.93 4.10 3.28 3.52 3.52 3.52 2.51 2.64 2.64 2.64 2.64 2.05 2.05 2.05 2.05 2.28 2.32 2.34 2.46 2.51 3.06 2.32 2.36
---------
3.54 3.09 3.57 3.63 3.27 3.60 4.55 3.67 4.63 3.84 3.34 4.67 3.87 4.90 3.93 3.52 6.18 5.01 4.10 3.52 2.64 3.57 3.64 4.59 3.82 3.32 4.55 3.67 4.63 3.84 4.72 3.90 3.52 4.59 4.90 3.93 6.12 4.97 4.10 3.52 6.29 5.27 4.10 3.52 2.64 4.63 3.84 4.55 4.72 3.90 6.07 4.10 3.52 4.67 6.12 4.97 4.10 6.23 5.05 4.10 3.52 6.59 5.27 4.10 3.52 2.64 4.91 6.24 5.05 4.10 6.54 5.27 4.10 3.52 6.68 5.27 4.10 3.52 2.64 7.03 5.27 4.10 3.52 3.04 3.09 2.34 2.46 2.51 3.06 3.09 3.15
--------------------------------------------------------------------------------------------
3.54 3.09 3.63 3.27 2.51 3.06 3.60 3.15
----------------------------------------------------------------------------------------------------
----------------------------------------------------------------------------------------------------
4.10 4.10 3.52 3.52 3.52 2.64 2.64 2.05 2.05 3.04 3.09 3.07 3.12 3.27 3.60 3.04 3.15 3.09 3.30 3.34 2.34 2.49 2.46 2.53 2.64 2.32 2.51 2.64 2.64 2.64 3.57 3.12 3.07 3.28 3.32 3.54 3.67 3.09 3.30 3.15 3.35 3.52 2.30 2.46 2.53 2.30 2.49 2.64 2.64 2.36 2.64 2.64 2.64 2.64 3.60 3.84 3.04 3.15 3.35 3.04 3.52 3.52 2.34 2.30 2.49 2.64 2.34 2.53 2.64 2.64 2.47 2.64 2.64 2.64 2.64 1.91 1.82 1.96 2.05 1.91 2.05 2.05 2.05 1.95 2.05 2.05 2.05 2.05 2.05 2.05 2.05 2.05 2.28 2.32 2.34 2.46 2.51 2.30 2.32 2.36
13.47 12.30 14.65 12.89 11.72 13.77 12.01 13.18 11.42 15.69 15.46 15.57 15.34 15.55 15.45 15.69 15.21 15.45 15.38 15.05 15.33 15.21 15.55 14.88 14.96 15.45 15.05 14.66 14.08 13.20 15.57 15.33 15.57 15.55 15.22 15.68 15.21 15.45 15.38 15.21 15.05 15.25 15.57 15.54 14.87 15.57 15.21 14.95 14.37 15.21 15.24 14.07 13.49 12.61 15.45 15.37 15.68 15.21 15.04 15.69 15.24 14.66 15.33 15.57 15.21 14.94 15.33 14.87 14.36 13.78 15.38 14.65 13.48 12.90 12.02 15.54 15.33 14.87 14.35 15.54 14.94 13.77 13.19 15.04 14.06 12.89 12.31 11.43 15.23 13.47 12.30 11.72 15.69 15.46 15.34 15.55 15.05 15.57 15.45 15.22
087086
Multi Combination Table
3Room
2Room
4Room
HEATING OPERATIONHeating Capacity
Room 1KW
Room 2KW
Room 4KW
Room 5KW
Room 6KW
Room 7KW
Room 8KW
Room 3KW
TotalKW KW
Input powerAOYG45LAT8 Combination of indoor unit
241818181414141414141212121212121212999999997777777
14141212121212121212121212999999999999999999999999977777777777777777777777777777
242418182418181414142418181414141212241818141412129
2418181414129
141414141412121212121212121414141412121212121212129999999999999
1814141414121212121212121212999999999997777
--
24182424182418142424182418142418242418241824182424241824182424141418141418141414121212121814141418141414121212121818141414121212129999
18181414141818141414121212121818141412121212999
24181814
---------------------------------
18141818141824181424181412182418141824181424181412241824181424181412241814121818241814241824181424181412241824182418141224181424241824
----------------------------------------------------------------------------------------------------
----------------------------------------------------------------------------------------------------
----------------------------------------------------------------------------------------------------
----------------------------------------------------------------------------------------------------
5.07 4.21 5.98 5.43 5.98 5.70 5.11 5.23 4.75 4.21 5.98 5.43 5.07 5.11 4.46 4.00 5.07 4.21 5.87 5.16 4.60 4.91 4.10 4.60 3.90 4.21 5.56 5.08 4.33 4.60 3.90 4.33 4.00 5.98 5.70 5.98 5.98 5.43 5.98 5.98 5.70 5.23 5.98 5.43 5.11 5.07 5.98 5.98 5.56 5.16 5.87 5.98 5.32 5.08 5.87 5.16 4.91 4.60 5.98 5.43 5.70 5.11 4.75 5.43 5.07 4.46 4.21 5.16 4.60 4.10 3.90 5.98 5.87 5.98 5.32 5.08 5.98 5.56 5.87 5.16 4.91 5.56 5.08 4.60 4.33 5.98 5.23 5.43 5.07 5.23 4.75 4.21 4.00 5.08 4.33 3.90 5.98 5.70 5.11 5.23
7.91 5.86 5.32 5.79 4.26 4.59 4.78 4.75 4.80 4.80 3.58 3.84 3.96 3.94 3.96 3.96 3.96 3.96 2.85 2.97 2.99 2.99 2.99 2.99 2.99 2.99 2.28 2.37 2.37 2.37 2.37 2.37 2.37 4.30 4.55 3.53 3.61 3.80 3.59 3.52 3.79 3.92 3.58 3.84 3.94 3.96 2.72 2.66 2.87 2.96 2.86 2.71 2.90 2.98 2.85 2.97 2.99 2.99 2.71 2.90 2.86 2.98 2.99 2.89 2.99 2.99 2.99 2.97 2.99 2.99 2.99 2.14 2.26 2.14 2.29 2.36 2.13 2.29 2.25 2.35 2.37 2.28 2.37 2.37 2.37 2.25 2.35 2.29 2.37 2.35 2.37 2.37 2.37 2.37 2.37 2.37 2.11 2.27 2.36 2.35
7.91 7.91 5.32 5.79 7.02 5.61 5.84 4.75 4.80 4.80 7.15 5.68 5.86 4.78 4.80 4.80 3.96 3.96 7.54 5.83 5.86 4.80 4.80 3.96 3.96 2.99 7.61 5.85 5.86 4.80 4.80 3.96 2.99 4.30 4.55 4.28 4.38 4.61 3.59 3.52 3.79 3.92 3.58 3.84 3.94 3.96 4.37 4.27 4.60 4.75 3.78 3.59 3.85 3.94 3.77 3.94 3.96 3.96 2.71 2.90 2.86 2.98 2.99 2.89 2.99 2.99 2.99 2.97 2.99 2.99 2.99 5.28 4.57 4.33 4.65 4.77 3.56 3.82 3.76 3.93 3.96 3.81 3.96 3.96 3.96 2.84 2.97 2.88 2.99 2.96 2.99 2.99 2.99 2.98 2.99 2.99 2.11 2.27 2.36 2.35
---------------------------------
5.24 4.55 5.22 5.34 4.61 5.32 7.02 5.61 4.75 7.15 5.68 4.78 3.96 5.33 7.04 5.62 4.75 5.60 7.17 5.69 4.78 7.54 5.83 4.80 3.96 7.16 5.68 7.55 5.83 4.80 7.65 5.86 4.80 3.96 7.86 5.86 4.80 3.96 5.28 5.58 7.14 5.67 4.77 7.10 5.65 7.52 5.82 4.80 7.61 5.85 4.80 3.96 7.51 5.81 7.63 5.86 7.84 5.86 4.80 3.96 7.89 5.86 4.80 7.03 7.57 5.84 7.83
----------------------------------------------------------------------------------------------------
----------------------------------------------------------------------------------------------------
----------------------------------------------------------------------------------------------------
----------------------------------------------------------------------------------------------------
--
7.18 5.79 7.02 7.57 5.84 7.82 5.86 4.80 7.15 7.67 5.86 7.87 5.86 4.80 7.91 5.86 7.54 7.87 5.86 7.91 5.86 7.91 5.86 7.91 7.61 7.90 5.86 7.91 5.86 7.91 7.91 4.30 4.55 5.22 4.38 4.61 5.32 4.26 4.59 4.75 3.58 3.84 3.94 3.96 5.33 4.27 4.60 4.75 5.60 4.35 4.66 4.78 3.77 3.94 3.96 3.96 5.30 5.68 4.58 4.78 4.80 3.83 3.96 3.96 3.96 2.97 2.99 2.99 2.99 5.28 5.58 4.33 4.65 4.77 5.26 5.65 4.56 4.77 4.80 3.81 3.96 3.96 3.96 5.56 5.81 4.63 4.80 3.92 3.96 3.96 3.96 2.98 2.99 2.99 7.03 5.61 5.84 4.75
15.82 13.77 17.82 17.38 18.31 17.77 16.46 17.32 15.46 14.40 17.89 17.19 15.68 16.59 14.62 13.56 15.83 13.78 17.93 16.67 14.71 15.70 13.65 14.86 12.81 13.89 17.51 16.12 14.09 15.08 13.03 14.24 13.27 18.13 18.20 18.24 17.71 17.62 17.82 18.32 17.77 17.33 17.90 17.20 16.60 15.84 17.76 18.25 17.68 17.22 17.84 17.83 17.11 16.48 17.94 16.67 15.71 14.87 17.88 17.17 17.85 16.56 15.58 17.27 15.80 14.74 13.90 16.77 14.83 13.77 12.93 17.98 17.99 17.94 17.26 16.67 18.05 17.41 18.09 16.87 15.93 17.51 16.13 15.09 14.25 18.15 16.95 17.42 16.02 17.08 15.18 14.12 13.28 16.23 14.21 13.15 18.28 17.73 16.40 17.27
8 Rooms Multi cooling 8 Rooms Multi heating
6Room
7Room
8Room
COOLING OPERATIONCooling Capacity
Room 1KW
Room 2KW
Room 4KW
Room 5KW
Room 6KW
Room 7KW
Room 8KW
Room 3KW
TotalKW KW
Input powerAOYG45LAT8 Combination of indoor unit
77777777777777777777777777777777777777777777777777777777777777777777
99977777777777777777777777777777777777777797777777777777777777777777
999
129999999999777777777777777777777777777799977777777777777777777777
999
12121299999999
121212999999999777777777777777799999977777777777777777777
9991212121412121299991412121414121212999914141212129999977777799999999997777777777777777
18129121412141814121814129141412181418141218141291814181412241814129241814129799999912999121299997777797777
------------------------------------------9129141291214129141218141291814129799777
---------------------------------------------------------------991297
5.88 5.90 5.79 5.87 5.88 5.89 5.89 5.87 5.90 5.90 5.89 5.90 5.90 5.50 5.88 5.89 5.90 5.87 5.90 5.89 5.90 5.90 5.90 5.90 5.65 5.20 5.89 5.90 5.90 5.90 5.79 5.88 5.90 5.65 5.35 4.89 5.89 5.90 5.35 5.05 4.57 4.24 5.88 5.87 5.89 5.87 5.89 5.90 5.88 5.89 5.90 5.90 5.88 5.89 5.87 5.90 5.90 5.90 5.89 5.90 5.90 5.65 5.35 5.87 5.89 5.88 5.90 5.90
1.79 1.93 2.05 1.77 1.79 1.82 1.80 1.77 1.83 1.92 1.82 1.93 1.96 2.05 1.79 1.82 1.91 1.77 1.84 1.80 1.92 1.95 1.91 1.96 2.05 2.05 1.80 1.92 1.84 1.95 2.05 1.79 1.93 2.05 2.05 2.05 1.82 1.96 2.05 2.05 2.05 2.05 1.78 1.77 1.82 1.77 1.80 1.91 1.79 1.80 1.83 1.93 1.79 1.82 1.77 1.84 1.92 1.96 1.80 1.92 1.95 2.05 2.05 1.77 1.80 1.79 1.84 1.92
2.30 2.49 2.64 1.77 1.79 1.82 1.80 1.77 1.83 1.92 1.82 1.93 1.96 2.05 1.79 1.82 1.91 1.77 1.84 1.80 1.92 1.95 1.91 1.96 2.05 2.05 1.80 1.92 1.84 1.95 2.05 1.79 1.93 2.05 2.05 2.05 1.82 1.96 2.05 2.05 2.05 2.05 2.30 1.77 1.82 1.77 1.80 1.91 1.79 1.80 1.83 1.93 1.79 1.82 1.77 1.84 1.92 1.96 1.80 1.92 1.95 2.05 2.05 1.77 1.80 1.79 1.84 1.92
2.30 2.49 2.64 3.04 3.07 3.12 2.32 2.28 2.36 2.47 2.34 2.49 2.53 2.64 3.07 3.12 3.28 2.28 2.36 2.32 2.47 2.51 2.46 2.53 2.64 2.64 1.80 1.92 1.84 1.95 2.05 1.79 1.93 2.05 2.05 2.05 1.82 1.96 2.05 2.05 2.05 2.05 2.30 2.28 2.34 2.28 2.32 2.46 1.79 1.80 1.83 1.93 1.79 1.82 1.77 1.84 1.92 1.96 1.80 1.92 1.95 2.05 2.05 1.77 1.80 1.79 1.84 1.92
2.30 2.49 2.64 3.04 3.07 3.12 3.60 3.04 3.15 3.30 2.34 2.49 2.53 2.64 3.57 3.12 3.28 3.54 3.67 3.09 3.30 3.35 2.46 2.53 2.64 2.64 3.60 3.84 3.15 3.35 3.52 2.30 2.49 2.64 2.64 2.64 1.82 1.96 2.05 2.05 2.05 2.05 2.30 2.28 2.34 2.28 2.32 2.46 2.30 2.32 2.36 2.49 1.79 1.82 1.77 1.84 1.92 1.96 1.80 1.92 1.95 2.05 2.05 1.77 1.80 1.79 1.84 1.92
4.59 3.32 2.64 3.04 3.57 3.12 3.60 4.55 3.67 3.30 4.67 3.87 3.37 2.64 3.57 3.64 3.28 4.55 3.67 4.63 3.84 3.35 4.90 3.93 3.52 2.64 4.63 3.84 4.72 3.90 3.52 6.12 4.97 4.10 3.52 2.64 6.24 5.05 4.10 3.52 2.64 2.05 2.30 2.28 2.34 2.28 2.32 2.46 3.07 2.32 2.36 2.49 3.07 3.12 2.28 2.36 2.47 2.53 1.80 1.92 1.95 2.05 2.05 2.28 1.80 1.79 1.84 1.92
------------------------------------------
2.30 3.04 2.34 3.54 3.09 2.46 3.07 3.60 3.15 2.49 3.57 3.12 4.55 3.67 3.30 2.53 4.63 3.84 3.35 2.64 2.05 2.28 2.32 1.79 1.84 1.92
---------------------------------------------------------------
2.28 2.32 3.07 2.36 1.92
2.30 2.49 2.64 3.04 2.30 2.34 2.32 2.28 2.36 2.47 2.34 2.49 2.53 2.64 1.79 1.82 1.91 1.77 1.84 1.80 1.92 1.95 1.91 1.96 2.05 2.05 1.80 1.92 1.84 1.95 2.05 1.79 1.93 2.05 2.05 2.05 1.82 1.96 2.05 2.05 2.05 2.05 2.30 2.28 2.34 1.77 1.80 1.91 1.79 1.80 1.83 1.93 1.79 1.82 1.77 1.84 1.92 1.96 1.80 1.92 1.95 2.05 2.05 1.77 1.80 1.79 1.84 1.92
15.57 15.22 15.25 15.69 15.57 15.34 15.45 15.69 15.21 15.38 15.33 15.21 14.88 14.66 15.57 15.33 15.55 15.68 15.21 15.45 15.38 15.05 15.54 14.87 14.95 14.07 15.45 15.37 15.21 15.04 15.24 15.57 15.21 14.94 14.36 13.48 15.33 14.87 14.35 13.77 12.89 12.30 15.57 15.69 15.34 15.69 15.45 15.55 15.57 15.45 15.21 15.21 15.57 15.33 15.68 15.21 15.38 14.87 15.45 15.37 15.04 14.94 14.35 15.69 15.45 15.57 15.21 15.37
Note: •Cooling capacity is based on 27°CDB/19°CWB(indoor temperature),35°CDB(outdoor temperature) •Pipe Length: 5m (Outdoor unit to Branch box), 3m (Branch box to Indoor unit) •Height difference: 0m (Outdoor unit to Indoor unit) •The values in this table should be used only as a guide. These values are calculated at standard conditions. When you select models finally, select them according to “Model Selection” in the D&T manual
Note: •Heating capacity is based on 20°CDB(indoor temperature),7°CDB/6°CWB(outdoor temperature) •Pipe Length: 5m (Outdoor unit to Branch box), 3m (Branch box to Indoor unit) •Height difference: 0m (Outdoor unit to Indoor unit) •The values in this table should be used only as a guide. These values are calculated at standard conditions. When you select models finally, select them according to “Model Selection” in the D&T manual
089088
Multi Combination Table
6Room
7Room
8Room
HEATING OPERATION
Room 1KW
Room 2KW
Room 4KW
Room 5KW
Room 6KW
Room 7KW
Room 8KW
Room 3KW
TotalKW KW
Input powerAOYG45LAT8Heating CapacityCombination
of indoor unit
77777777777777777777777777777777777777777777777777777777777777777777
99977777777777777777777777777777777777777797777777777777777777777777
999
129999999999777777777777777777777777777799977777777777777777777777
999
12121299999999
121212999999999777777777777777799999977777777777777777777
999
121212141212129999
14121214141212129999
14141212129999977777799999999997777777777777777
18129
121412141814121814129
14141218141814121814129
1814181412241814129
2418141297999999
12999
121299997777797777
------------------------------------------9
129
14129
1214129
14121814129
1814129799777
---------------------------------------------------------------99
1297
5.98 5.56 5.23 5.98 5.98 5.98 5.98 5.98 5.98 5.70 5.98 5.56 5.32 5.11 5.98 5.98 5.87 5.98 5.98 5.98 5.70 5.43 5.87 5.32 5.16 5.07 5.98 5.70 5.98 5.43 5.23 5.98 5.56 5.16 5.08 4.75 5.98 5.32 5.08 4.91 4.46 4.21 5.98 5.98 5.98 5.98 5.98 5.87 5.98 5.98 5.98 5.56 5.98 5.98 5.98 5.98 5.70 5.32 5.98 5.70 5.43 5.16 5.08 5.98 5.98 5.98 5.98 5.70
2.12 2.28 2.35 2.11 2.11 2.15 2.12 2.11 2.16 2.27 2.15 2.27 2.30 2.36 2.10 2.14 2.25 2.10 2.15 2.14 2.26 2.29 2.25 2.29 2.35 2.37 2.13 2.25 2.17 2.28 2.35 2.12 2.28 2.35 2.36 2.37 2.14 2.30 2.36 2.37 2.37 2.37 2.12 2.10 2.15 2.09 2.13 2.25 2.11 2.12 2.16 2.27 2.10 2.14 2.10 2.15 2.26 2.29 2.13 2.25 2.28 2.35 2.36 2.09 2.12 2.11 2.15 2.25
2.68 2.87 2.96 2.11 2.11 2.15 2.12 2.11 2.16 2.27 2.15 2.27 2.30 2.36 2.10 2.14 2.25 2.10 2.15 2.14 2.26 2.29 2.25 2.29 2.35 2.37 2.13 2.25 2.17 2.28 2.35 2.12 2.28 2.35 2.36 2.37 2.14 2.30 2.36 2.37 2.37 2.37 2.67 2.10 2.15 2.09 2.13 2.25 2.11 2.12 2.16 2.27 2.10 2.14 2.10 2.15 2.26 2.29 2.13 2.25 2.28 2.35 2.36 2.09 2.12 2.11 2.15 2.25
2.68 2.87 2.96 3.52 3.53 3.60 2.67 2.66 2.72 2.86 2.72 2.86 2.90 2.97 3.51 3.58 3.77 2.65 2.71 2.70 2.85 2.89 2.84 2.89 2.97 2.99 2.13 2.25 2.17 2.28 2.35 2.12 2.28 2.35 2.36 2.37 2.14 2.30 2.36 2.37 2.37 2.37 2.67 2.65 2.71 2.63 2.69 2.84 2.11 2.12 2.16 2.27 2.10 2.14 2.10 2.15 2.26 2.29 2.13 2.25 2.28 2.35 2.36 2.09 2.12 2.11 2.15 2.25
2.68 2.87 2.96 3.52 3.53 3.60 4.29 3.52 3.61 3.78 2.72 2.86 2.90 2.97 4.26 3.58 3.77 4.25 4.35 3.57 3.77 3.82 2.84 2.89 2.97 2.99 4.31 4.56 3.62 3.81 3.92 2.67 2.87 2.96 2.98 2.99 2.14 2.30 2.36 2.37 2.37 2.37 2.67 2.65 2.71 2.63 2.69 2.84 2.67 2.68 2.73 2.87 2.10 2.14 2.10 2.15 2.26 2.29 2.13 2.25 2.28 2.35 2.36 2.09 2.12 2.11 2.15 2.25
5.25 3.81 2.96 3.52 4.28 3.60 4.29 5.21 4.37 3.78 5.33 4.60 3.84 2.97 4.26 4.34 3.77 5.19 4.35 5.28 4.57 3.82 5.57 4.64 3.93 2.99 5.26 4.56 5.36 4.62 3.92 7.06 5.63 4.76 3.95 2.99 7.16 5.68 4.78 3.96 2.99 2.37 2.67 2.65 2.71 2.63 2.69 2.84 3.53 2.68 2.73 2.87 3.52 3.58 2.65 2.71 2.85 2.89 2.13 2.25 2.28 2.35 2.36 2.64 2.12 2.11 2.15 2.25
------------------------------------------
2.67 3.51 2.71 4.23 3.56 2.84 3.53 4.30 3.61 2.87 4.26 3.58 5.19 4.36 3.78 2.89 5.26 4.56 3.81 2.96 2.36 2.64 2.68 2.11 2.15 2.25
---------------------------------------------------------------
2.64 2.68 3.52 2.72 2.25
2.68 2.87 2.96 3.52 2.66 2.71 2.67 2.66 2.72 2.86 2.72 2.86 2.90 2.97 2.10 2.14 2.25 2.10 2.15 2.14 2.26 2.29 2.25 2.29 2.35 2.37 2.13 2.25 2.17 2.28 2.35 2.12 2.28 2.35 2.36 2.37 2.14 2.30 2.36 2.37 2.37 2.37 2.67 2.65 2.71 2.09 2.13 2.25 2.11 2.12 2.16 2.27 2.10 2.14 2.10 2.15 2.26 2.29 2.13 2.25 2.28 2.35 2.36 2.09 2.12 2.11 2.15 2.25
18.10 17.57 17.16 18.29 18.23 17.81 18.16 18.27 17.74 17.82 17.79 17.73 17.15 16.61 18.34 17.92 18.06 18.38 17.85 17.96 17.97 17.39 18.03 17.30 16.92 16.07 18.07 18.12 17.65 17.54 17.23 18.19 17.60 17.11 16.38 15.46 17.88 17.18 16.57 15.81 14.84 14.22 18.16 18.33 17.85 18.40 18.02 18.11 18.20 18.13 17.71 17.68 18.31 17.89 18.35 17.82 17.93 17.26 18.04 18.08 17.50 17.06 16.52 18.40 18.10 18.28 17.79 18.04
4Room
5Room
6Room
HEATING OPERATIONHeating Capacity
Room 1KW
Room 2KW
Room 4KW
Room 5KW
Room 6KW
Room 7KW
Room 8KW
Room 3KW
TotalKW KW
Input powerAOYG45LAT8 Combination of indoor unit
777777777
121299999999999999999997777777777777777777777777777777777777777777777777777777777777799999777
777777777
12121212129999999999999999
121212121299999999999999999997777777777777777777777777777777777777799999999
14141212129977
12121212121412121212129999999999
141212121214141212121212999999999999
141412121212121299999999999997777777777777777799999999
1814241814241824181212141212141414121212141412121299999141412121214141414121212181414121212129999914141814141212121814141412121212999991814141412121212999997777999991299
---------
1412141412141814181412181418141224181412914141814121814181418141218181424181412241814129181418181424141218241814241814122418141291824181424181412241814129241814121212999121212
--------------------------------------------------------------------------------------------
141214129
121412
----------------------------------------------------------------------------------------------------
----------------------------------------------------------------------------------------------------
4.75 4.21 5.11 4.46 4.00 4.91 4.10 4.60 3.90 5.98 5.98 5.98 5.98 5.87 5.98 5.98 5.98 5.98 5.70 5.43 5.98 5.56 5.87 5.32 5.16 5.98 5.43 5.11 5.07 4.60 5.98 5.98 5.98 5.87 5.56 5.98 5.98 5.98 5.70 5.98 5.43 5.23 5.98 5.87 5.32 5.98 5.56 5.16 5.08 5.98 5.23 5.07 4.75 4.33 5.98 5.70 5.98 5.98 5.43 5.98 5.23 5.11 5.98 5.98 5.56 5.16 5.98 5.32 5.08 4.91 5.70 5.11 4.75 4.46 4.10 5.87 5.98 5.32 5.08 5.87 5.16 4.91 4.60 5.43 5.07 4.46 4.21 3.90 5.23 4.75 4.21 4.00 5.98 5.98 5.98 5.87 5.43 5.98 5.98 5.98
2.37 2.37 2.36 2.37 2.37 2.37 2.37 2.37 2.37 3.51 3.58 2.66 2.71 2.85 2.67 2.66 2.72 2.71 2.86 2.89 2.71 2.86 2.85 2.90 2.97 2.70 2.89 2.97 2.99 2.99 2.10 2.14 2.13 2.25 2.28 2.09 2.14 2.13 2.26 2.25 2.28 2.35 2.13 2.25 2.29 2.12 2.28 2.35 2.37 2.17 2.35 2.37 2.37 2.37 2.12 2.25 2.11 2.16 2.28 2.11 2.35 2.36 2.16 2.11 2.27 2.35 2.15 2.34 2.36 2.37 2.27 2.36 2.37 2.37 2.37 2.26 2.14 2.30 2.36 2.25 2.35 2.37 2.37 2.29 2.37 2.37 2.37 2.37 2.35 2.37 2.37 2.37 2.65 2.70 2.71 2.85 2.89 2.12 2.13 2.17
2.37 2.37 2.36 2.37 2.37 2.37 2.37 2.37 2.37 3.51 3.58 3.52 3.59 3.77 2.67 2.66 2.72 2.71 2.86 2.89 2.71 2.86 2.85 2.90 2.97 2.70 2.89 2.97 2.99 2.99 3.51 3.57 3.56 3.76 3.81 2.64 2.71 2.69 2.85 2.84 2.88 2.96 2.69 2.84 2.89 2.68 2.88 2.97 2.98 2.74 2.96 2.99 2.99 2.99 2.12 2.25 2.11 2.16 2.28 2.11 2.35 2.36 2.16 2.11 2.27 2.35 2.15 2.34 2.36 2.37 2.27 2.36 2.37 2.37 2.37 2.26 2.14 2.30 2.36 2.25 2.35 2.37 2.37 2.29 2.37 2.37 2.37 2.37 2.35 2.37 2.37 2.37 2.65 2.70 2.71 2.85 2.89 2.68 2.69 2.74
5.86 4.80 7.87 5.86 4.80 7.91 5.86 7.91 5.86 3.51 3.58 4.27 3.59 3.77 4.28 4.26 4.37 3.58 3.78 3.83 4.36 4.59 3.78 3.84 3.93 2.70 2.89 2.97 2.99 2.99 4.25 4.33 3.56 3.76 3.81 4.24 4.34 4.32 4.57 3.76 3.82 3.92 5.27 4.56 4.64 3.55 3.81 3.93 3.95 2.74 2.96 2.99 2.99 2.99 4.30 4.55 5.23 4.38 4.61 3.52 3.92 3.94 5.34 4.28 4.61 4.75 3.60 3.92 3.95 3.96 2.86 2.98 2.99 2.99 2.99 5.58 4.34 4.65 4.77 3.77 3.93 3.96 3.96 2.89 2.99 2.99 2.99 2.99 2.35 2.37 2.37 2.37 2.65 2.70 2.71 2.85 2.89 3.55 2.69 2.74
---------
4.26 3.58 4.27 4.35 3.77 4.28 5.21 4.37 5.30 4.58 3.83 5.32 4.59 5.59 4.65 3.93 7.14 5.67 4.77 3.96 2.99 4.25 4.33 5.26 4.56 3.81 5.18 4.34 5.28 4.57 5.56 4.63 3.92 5.27 5.57 4.64 7.08 5.64 4.76 3.95 7.24 5.81 4.79 3.96 2.99 5.25 4.55 5.23 5.35 4.61 7.03 4.75 3.94 5.34 7.05 5.62 4.75 7.18 5.80 4.78 3.96 7.56 5.83 4.80 3.96 2.99 5.58 7.15 5.68 4.77 7.52 5.82 4.80 3.96 7.63 5.86 4.80 3.96 2.99 7.83 5.86 4.80 3.96 3.51 3.57 2.71 2.85 2.89 3.55 3.56 3.62
--------------------------------------------------------------------------------------------
4.25 3.57 4.34 3.77 2.89 3.55 4.31 3.62
----------------------------------------------------------------------------------------------------
----------------------------------------------------------------------------------------------------
4.80 4.80 3.94 3.96 3.96 2.99 2.99 2.37 2.37 3.51 3.58 3.52 3.59 3.77 4.28 3.52 3.60 3.58 3.78 3.83 2.71 2.86 2.85 2.90 2.97 2.70 2.89 2.97 2.99 2.99 4.25 3.57 3.56 3.76 3.81 4.24 4.34 3.57 3.77 3.76 3.82 3.92 2.69 2.84 2.89 2.68 2.88 2.97 2.98 2.74 2.96 2.99 2.99 2.99 4.30 4.55 3.53 3.62 3.80 3.52 3.92 3.94 2.72 2.67 2.87 2.96 2.72 2.96 2.98 2.99 2.86 2.98 2.99 2.99 2.99 2.26 2.14 2.30 2.36 2.25 2.35 2.37 2.37 2.29 2.37 2.37 2.37 2.37 2.35 2.37 2.37 2.37 2.65 2.70 2.71 2.85 2.89 2.68 2.69 2.74
15.40 14.34 16.53 14.56 13.50 15.64 13.59 15.02 12.97 18.32 17.90 18.26 17.84 17.95 18.19 18.30 17.77 17.88 17.86 17.28 17.82 17.77 17.92 17.19 16.78 17.94 17.25 16.67 15.92 14.95 18.37 17.95 18.06 18.10 17.52 18.40 17.88 17.99 18.01 18.16 17.43 17.09 18.04 18.07 17.34 18.11 17.49 16.97 16.24 17.63 17.05 16.12 15.30 14.33 18.10 18.16 18.21 17.68 17.58 18.29 17.28 16.54 17.73 18.22 17.64 17.16 17.80 17.36 16.43 15.65 17.81 16.51 15.52 14.68 13.71 17.95 17.91 17.22 16.62 18.05 16.81 15.87 15.03 17.38 15.96 14.90 14.06 13.09 17.22 15.34 14.28 13.44 18.36 17.94 17.88 18.00 17.33 18.12 18.05 17.63
Note: •Heating capacity is based on 20°CDB(indoor temperature),7°CDB/6°CWB(outdoor temperature) •Pipe Length: 5m (Outdoor unit to Branch box), 3m (Branch box to Indoor unit) •Height difference: 0m (Outdoor unit to Indoor unit) •The values in this table should be used only as a guide. These values are calculated at standard conditions. When you select models finally, select them according to “Model Selection” in the D&T manual
8 Rooms Multi heating 8 Rooms Multi heating
Note: •Heating capacity is based on 20°CDB(indoor temperature),7°CDB/6°CWB(outdoor temperature) •Pipe Length: 5m (Outdoor unit to Branch box), 3m (Branch box to Indoor unit) •Height difference: 0m (Outdoor unit to Indoor unit) •The values in this table should be used only as a guide. These values are calculated at standard conditions. When you select models finally, select them according to “Model Selection” in the D&T manual
091090
Simultaneous Multi Twin / Triple
AOYG36LATT
CLASSA
ALLDC
AOYG45LATT
CLASSA
ALLDC
AOYG54LATT
CLASSA
ALLDC
Can support various installation scenes from office to commercial space by same place multi connection of up to 3units.
Indoor units distributed layout according to the shape and number of people and lighting conditions of the room even on wide floors and atypical floors. Ideal comfortable air flow distribution can be realized.
Low noise mode: Suppresses night time operating sound.Peak cut function: Suppresses maximum capacity and performs energy saving operation and can prevent breaker tripping.
Max 16 indoor units are simultaneously controlled with a wired remote controller.
Installation according tofloor layout
Installation according tolighting conditions
Installation according tolayout and lighting conditions
Specifications Dimensions Models: (Unit : mm)AOYG36LATT / AOYG45LATT / AOYG54LATT
Simultaneous control
Low ambient operation External input
Four directions piping connection is possible. The perfect route can be selected according to the installation.
Piping connection
50
40
30
20
10
0
-10
46°C
-15°C
Cooling
24°CHeating
-15°C
330
31
650132
400
362.
524
400
900
9
33031 12
Top view
1290
21
SU MO TU WE TH FR SA
7
3 126 9 15 18 21
Transmission cable
Indoor unit 0(Master)
WiredRemort Controller
Remote controller cable Bus wire
Indoor unit 1
Indoorunit 2
Indoorunit 14
Indoor unit 3
Indoor unit 15
Refrigerant pipe
Set the indoor unit number using DIP switch on indoor unit circuit board.
1Front 2
Bottom
3Right
4Back
Net Dimension H x W x DWeight
Power Source
kg(lbs)mm
V/ Ø/HzAUYG18LVLB
245x570x570
Model No. Indoor unitAUYG22LVLA
Compact CassetteAUYG24LVLA
230/1/50680/580/490/410
15 (33)UTG-UFYD-W
245x570x570
230/1/501030/830/600/450
17(36)UTG-UFYD-W
245x570x570
230/1/501030/830/600/450
17(36)UTG-UFYD-W
Net Dimension H x W x DWeightPiping Connections (Small / Large)
Operation RangeCoolingHeating
Max Pipe Length (Pre-Charge)
Refrigerant
Power Source
kg(lbs)mm
mm
mm
°CDB
V/ Ø/Hz
AOYG36LATT
1290x900x330
9.52/15.8875(30)
30
-15~24R410A
Model No. Outdoor unit AOYG45LATT AOYG54LATT
UTP-SX236A(Twin)
400/3/50
105(229)
Height Difference-15~46
1290x900x330
9.52/15.8875(30)
30
-15~24R410A
UTP-SX254A(Twin)
400/3/50
105(229)
-15~46
1290x900x330
9.52/15.8875(30)
30
-15~24R410A
UTP-SX254A(Twin)/UTP-SX354A(Triple)
400/3/50
105(229)
-15~46
Separation tube
*Different type and capacity indoor units can not be connected .
Air Flow (High)
Decoration Panel
Cooling H/M/L/Q m3/h
Net Dimension H x W x DWeight
Power Source
kg(lbs)mm
V/ Ø/HzARYG18LLTB
198 x 900 x 620
Model No. Indoor unitARYG22LMLA
DuctARYG24LMLA
230/1/50830/670/580/480
23 (51)270 x 1135 x 700
230/1/501100/910/750/580
38 (84)
ABYG18LVTB
199 x 990 x 655
ABYG22LVTAFloor/Ceiling Universal
ABYG24LVTA230/1/50
780/700/560/500
27 (60)199 x 990 x 655
230/1/50980/820/680/540
27 (60)
Air Flow (High) Cooling H/M/L/Q m3/h
093092
Big Multi
CAPACITY(BTU)
45,00036,00030,000
(25,000)24,00018,000
Indoor Unit LineupCEILING(LARGE)
FLOOR/CEILINGUNIVERSALDUCTCASSETTE
CAPACITY(BTU)
45,00036,00030,000
(25,000)24,00018,000
Indoor Unit LineupCEILING(LARGE)
FLOOR/CEILINGUNIVERSALDUCTCASSETTE
Chargeless30m
Outdoor units can be grouped together in a row.
Hei
ght d
iffer
ence
: 30
m m
ax.
Actual pipe length : 50m max.
Indoor unit Indoor unit Indoor unit Indoor unit
Outdoor unit
Wired remotecontroller
UTB-YUB (option)
Refrigerant System (Simultaneous Operation) Gas pipe
Liquid pipe
Separation tube UTR-BP901
Gas pipe
Liquid pipe
Separation tube UTR-BP901
Outdoor units can be grouped together in a row.
Chargeless30m
Hei
ght d
iffer
ence
: 30
m m
ax.
Actual pipe length : 50m max.
Indoor unit Indoor unit
Indoor unit Indoor unitOutdoor unit
Wired remotecontroller
UTB-YUB (option)
Wired remotecontroller
UTB-YUB (option)
Refrigerant System (Individual Operation)
Model name
Specifications
Capacity
Moisture Removal
Power Source 220-240/1/505.20~5.305.50~5.60
17,800~18,10018,800~19,100
2.2080068056030
Sirocco x 2199x990x655
28Flare
9.53/15.8818~3016~30
-
Model name AJYA90EATA380-415/W4/50
25.40 -
9.40 -
16.20 -
63.00 2.70
-730360
9,800Propeller x 2
150x21,380x1,300x650
24357
27/1920/(15)35/24
7/6R407C3.1x2
9.53/19.05503030
0~52-10~21
CoolingHeatingCoolingHeating
HighMedLow
kW
BTU/h
m3/h
V/ø/Hz
W
mm
ºC
AirflowRate
Grille
Net Dimension H x W x DWeight
Connection MethodConnection Pipe Size (Smallø/Largeø)
Fan Motor OutputFan Type x Q’ty
l/h
CoolingHeating
Operation Range
mmkg
220-240/1/506.50~6.607.60~7.70
22,200~22,50025,900~26,300
3.4090078066040
Sirocco x 2199x990x655
30Flare
9.53/15.8818~3016~30
-
220-240/1/508.60~8.808.80~9.10
29,400~30,00030,000~31,000
4.00 1,2701,120860160
Sirocco x 4240x1,660x700
48Flare
9.53/15.8818~3016~30
-
220-240/1/5010.30~10.5010.50~10.70
35,200~36,00036,000~36,500
4.00 1,6601,5001,270160
Sirocco x 4240x1,660x700
48Flare
9.53/19.0518~3016~30
-
220-240/1/5012.40~12.7013.40~13.70
42,500~43,50046,000~47,000
5.501,8501,6601,430160
Sirocco x 4240x1,660x700
48Flare
9.53/19.0518~3016~30
-
220-240/1/506.95~7.057.60~7.85
23,700~24,10025,900~26,800
2.501,6001,4501,280
70Sirocco x 2
270x1,210x70043
Flare9.53/15.88
18~3016~30
-
220-240/1/508.60~8.808.80~9.10
29,400~30,00030,000~31,000
3.00 1,6501,5501,350275
Sirocco x 2270x1,210x700
43Flare
9.53/15.8818~3016~30
-
220-240/1/5010.30~10.5010.50~10.70
35,200~36,00036,000~36,500
4.00 2,0001,8001,600275
Sirocco x 2270x1,210x700
45Flare
9.53/19.0518~3016~30
-
220-240/1/5012.40~12.7013.40~13.70
42,500~43,50046,000~47,000
5.502,2002,0001,800275
Sirocco x 2270x1,210x700
45Flare
9.53/19.0518~3016~30
-
220-240/1/504.85~5.005.30~5.45
19,000~19,90021,000~21,600
2.1065055049014
Turbo x 1235x580x580(+70)
18Flare
9.53/15.8818~3016~30
UTG-UDYD-W
220-240/1/506.95~7.057.60~7.85
23,700~24,10025,900~26,800
2.501,17097077090
Turbo x 1296x830x830
38Flare
9.53/15.8818~3016~30
-
220-240/1/508.60~8.808.80~9.10
29,400~30,00030,000~31,100
3.00 1,2701,07088090
Turbo x 1296x830x830
38Flare
9.53/15.8818~3016~30
-
220-240/1/5010.30~10.5010.50~10.70
35,200~36,00035,800~36,500
4.00 1,5001,3001,100
90Turbo x 1
296x830x83040
Flare9.53/19.05
18~3016~30
-
220-240/1/5012.40~12.7013.40~13.70
42,300~43,40045,800~46,800
5.00 1,6501,4501,200
90Turbo x 1
296x830x83040
Flare9.53/19.05
18~3016~30
-
Power Source
Total Capacity CoolingHeatingCoolingHeatingCoolingHeating
CoolingHeatingCoolingHeating
CoolingHeating
CoolingHeating
HighLowHigh
Total Input Watts
Total Ampacity
Starting CurrentEERCOP
Fan Speed
Airflow RateFan Type x Q'tyFan Motor OutputNet Dimension H x W x DWeightNoise Level(Sound Pressure)
Condition
Refrigerant
Pipe
Operation(Outdoor)
Type
IndoorAir Temp.Outdoor
Air Temp.
Max LengthMax Height
Max Chargeless Length
Size
V/ø/Hz
kW
kW
W/W
r.p.m
A
A
m3/h
Wmmkg
db(A)
kgmm
DB/WB(ºC)
DB/WB(ºC)
m
ºC
ChargeLiquid/Gas
AJYA90TATA380-415/W4/50
25.40 28.60 9.40 10.00 16.20 17.00 63.00 2.70 2.86 730360
9,800Propeller x 2
150x21,380x1,300x650
24557
27/1920/(15)35/247/6
R407C3.1x2
9.53/19.05503030
0~52-10~21
AJYA90EATB380-415/W4/50
25.40 -
9.40 -
16.20 -
63.00 2.70
-730360
9,800Propeller x 2
150x21,380x1,300x650
24357
27/1920/(15)35/247/6
R407C6.00
12.70/28.58503030
0~52-10~21
AJYA90TATB380-415/W4/50
25.40 28.60 9.40 10.00 16.20 17.00 63.00 2.70 2.86 730360
9,800Propeller x 2
150x21,380x1,300x650
24557
27/1920/(15)35/247/6
R407C6.00
12.70/28.58503030
0~52-10~21
Individual Operation Simultaneous Operation
Outdoor unitIndoor unit
Indoor unit
Outdoor unit
ABYA18TATA ABYA24TATA ABYA30TATA ABYA36TATA ABYA45TATA ARXA25TATA ARXA30TATA ARXA36TATA ARXA45TATA AUXA18TATA AUYA25TATA AUYA30TATA AUYA36TATA AUYA45TATA
Simultaneous OperationFeatures of System Operations•Simultaneous Operating System suitable for large spaces such as offices, lobbies and waiting rooms of high-rise buildings.
•One controller can simultaneously control cooling or heating by 2~4 indoor units.
Individual OperationFeatures of System Operations•Individual Operating System is suitable for large spaces such as hotels,commercial spaces, offices and restaurants.
•The system can cool and heat individually, because it has two refrigeration cycles.
CASSETTE(COMPACT)
CASSETTE(COMPACT)
Dimensions Models: (Unit : mm)AJYA90EATA / AJYA90TATA / AJYA90EATB / AJYA90TATB
Top view
Front view Right viewRear view
1000850
678
1380
1300 703650400400250
304
392424
24long hole
095094
Optional Parts for Split & Multi Split
Type
UTY-RNNYMUTY-RNNYMUTY-RNNYM
Refrigerant Piping Parts
UTP-SX236A / UTP-SX254A
Separation TubeFor 3-phase simultaneous multi
UTP-PY03A / UTP-PY02A
Branch BoxFor 8 Rooms Multi
UTP-SX354A
For 3-phase simultaneous multi For 8 Rooms Multi
UTP-SX248A
Liquid pipeuid pipe
Gas pipe
3 zones type 2 zones type
Controllers
UTY-DMMYMUTY-RNNYM
Central Remote ControllerFor 8 Rooms Multi
Wired Remote Controller Simple Remote Controller
UTY-RSNYM
Wired RemoteController
Simple Remote Controller
Central Remote Controller
Communication Kit
External Connect Kit
Auto Louver Grille Kit
Remote Sensor Unit
Long Life Filter
Flange
Drain PumpUnit
Wide Panel
PanelSpacer
Fresh Air Intake Kit
Air Outlet Shutter Plate
AdditionalGrille
Half Concealed Kit
Insulation for High Humidity
ExternalConnect Kit
ExternalConnect Kit(For Base heater)
Separation Tube
Branch Box
CeilingFloor Ceiling /Floor
DuctWall Mounted
Compact Compact
AUYF24LB
ARYF24LB, ARYA30/36LB,45LC
ASYG09/12LT
ASYG07/09/12/14LU
ASYG07/09/12LE
ASYG14LE
ASYG07/09/12LJ
ASYG18/24/30LF
ARYG07/09/12/14LLTB
ARY25/30/36/45UU
AGYF 09/12/14LA
AGYG09/12/14LV
ABYF24LB
AUYG07/09/12/14/18LVLB
AUYA30/36LB, 45/54LC
AUY25/30/36/45/54UU
ARYC45/54LC
ARY60UU
ABYG14/18LVTB
ABYA30/36LB, 45/54LC
ABY30/36/45/54UB
ARY90TL
ARYG18LLTB
ARY18UU
Large LargeSlim Compact Medium static High static
Oth
ers
Refri
geran
t pipi
ng pa
rts
Optional Parts ListConnection Units
For Individual & Centralized Control
AUY18UB
Cassette
UTY-RNNYMUTY-RNNYM
UTY-TWBXF UTY-XCBXE
UTY-XWZXZ5 UTY-XWZX
UTD-GXSA
UTD-GXSB
UTY-XSZX
UTD-LF25NA
UTD-RF204UTD-SF045T
UTZ-PX1NBA
UTG-AGYA-W
UTG-BGYA-W
UTZ-VXGAUTZ-VXAA
UTR-YDZCUTR-YDZB
UTZ-KXGA
UTR-STA
3-phase
Single Split (AOYA45 / 54LC)
UTY-XWZXZ3
UTY-XWZXZ4
8 Rooms Multi (AOYG45LAC8) Single Split (AOYD36 / 45 / 54LA) Simultaneous Multi (AOYD36 / 45 / 54LA)
UTP-SX248A
UTP-PY03A / UTP-PY02A
UTZ-KXGC
UTG-AGEA-W
UTG-AGDA-W
UTZ-PX1BBA
UTD-RF204
UTR-DPB24T
UTD-LF60KA
External Control Set UTD-ECS5A
UTY-XWZX
UTD-ECS5A UTD-ECS5A
UTD-ECS5A
UTY-XWZX UTY-XWZX
UTY-XCBXZ1
UTY-DMMYM UTY-DMMYM UTY-DMMYM
UTY-LRHYM UTY-LRJY1
UTY-LRHY1
UTY-LRHYA1
UTY-DMMYM
UTY-DMMYM
UTY-DMMYM
UTY-RSNYM UTY-RSNYM UTY-RSNYM
UTY-RSNYM
UTY-RSNYMUTY-RSNYM
UTY-RNNYMUTY-RNNYM
UTY-RSNYM
UTY-XWZX
UTY-XWZX
UTY-RNNYMUTY-RNNYM
Con
trol
lers
IR Receiver Kitwith Wireless Remote Controller
Panels
UTG-UDYD-W UTG-UFYB -W / UTG-UFYD-W UTG-UGYA-W
Decoration Panel
Oth
ers
Type
For Cassette type
UTY-XWZXZ2
UTP-SX236A / UTP-SX254A / UTP-SX354A
Single-phase
097096
Optional Parts for Split & Multi Split
For Cassette type
For Floor type
For Duct type
For Ceiling type
Others
IR Receiver KitFor Cassette type
IR Receiver KitFor Duct type
UTY-LRHYA1
UTY-LRHY1 / UTY-LRJY1UTY-LRHYM
+
UTD-LF25NA UTZ-PX1BBA / UTZ-PX1NBA
Long-Life Filter
UTD-LF60KA
This kit is used to half conceal floor type indoor unitinto the wall.
UTR-STA
Half Concealed Kit
Shuts the air outlet when only using as 2 or 3 blow out.
Indoor unit950
Panel 600
600(mm)
Panel spacer
242mm
UTG-AGYA-W
Wide Panel
UTG-BGYA-W
Panel Spacer
UTZ-VXAA UTZ-VXGA
Fresh Air Intake Kit
UTG-AGDA-W
Additional Grille
For Cassette typeFor Compact Cassette type
UTR-YDZB UTR-YDZC
Air Outlet Shutter Plate
For Cassette typeFor Compact Cassette type
UTZ-KXGA / UTZ-KXGC
Insulation KitFor High Humidity
For Compact Cassette type / Cassette type
Insulation Kit
UTG-AGEA-W
Remote Sensor Unit
UTY-XSZX
Auto Louver Grille Kit
UTD-GXSA (For 07 / 09 / 12 / 14 type)UTD-GXSB (For 18 type)
Simple flat Auto Louver will provide comfort airflow and harmonize with luxury interior.
Wired RemoteController
Wireless RemoteController
4 steps selectable and auto swing
Auto Louver Grille Duct type
New amenity space can be offered by installing the Remote sensor.
Drain Pump Unit
Drain Pump Unit
UTR-DPB24T
Flange
UTD-RF204(Round)
UTD-SF045T(Square)
IR Receiver Kit
Duct type indoor unit
WirelessRemote Controller
Use to connect with various peripheral devices andair conditioner PC board.
Communication KitFor Compact Wall Mounted type
UTY-TWBXF / UTY-XCBXE / UTY-XCBXZ1
External Control SetFor Indoor Unit (Duct type only)
UTD-ECS5A
External Connect KitFor Outdoor unit
UTY-XWZXZ4
For AOYG45LAC8 (For Base heater)
UTY-XWZXZ3
For AOYA45 / 54LC, AOYG45LAC8
UTY-XWZXZ2
External Connect KitFor Indoor Unit *Duct type is excluded.
UTY-XWZX / UTY-XWZXZ5 For LT / LU only
Communication System
For AOYD36 / 45 / 54LA, AOYD36 / 45 / 54LA
098
Comfort is required of spaces where people gather.VRF is a large multi system that effectively air conditions a wide range of spaces from large buildings to personal residences.This system makes a variety of spaces comfortable utilizing high environmental performance and powerful but pleasant operation.
TMAIRSTAGE creates a comfortable space with a wide range of series variations.
AIRSTAGETMS Heat recovery type
AIRSTAGETMJ-II Heat pump type
AIRSTAGETMV-II Heat pump type
Control Systems
Optional Parts for VRF
100
110
116
134
152
101100
2.98*Cooling EER
3.15 *Heating COP
High Efficiency
Smooth operation deliveringhigh efficiencies
Operating system
Cooling and heating can be performed simultaneously within the same refrigerant circuit. Energy savings are made by transferring heat between the indoor units when in heat recovery operation.
Power accumulation technology
Flow rate to the indoor unit(s) is controlled through the use of 3 differently rated compressors operating in a sequential step arrangement. While power accumulation technology controls the circulating load of the refrigerant flow between those steps.
Comfortable Operation
Heat recovery operation
Heat recovery operation is a cooling/heating free operation system, cooling and heating can be performed simultaneously in the same refrigerant system according to user needs. At the moment, the Heat Recovery operation is an extremely superior type that provides a still greater energy saving effect by moving heat between indoor units that are performing the cooling and heating operations. This is by having the compressors act like a pump.
The configuration of 3 constant speed compressors with differing capacities and power accumulation technology ensure smooth step changes and highly efficient operation.
*EER/COP values are base on our own testing method.
High Reliability
Recovery operation
Outdoor Unit: In the event of compressor failure an alarm is automatically triggered and the remaining compressor(s) will continue to operate, thereby ensuring continuous operation when possible.
Comp.1
Comp.2
Comp.3
Improved Comfort
Quiet operation
Operational noise has been reduced yet further through the application of a new dual casing bell-mouth and large fan. When set to silent operation, noise levels can be reduced by 5-6dB(A) compared to normal operation.
55dB(A)
Normal operation mode
50dB(A)
Silent operation mode
(380V)
Maximum comfort frominbuilt flexibility
Heat recoveryAO90MPCMF
2
3 3 3
1
1 2
1 2 3
Req
uire
d c
apac
ity
Operating capacitylow High
High
Wide operating range
5040302010
0-10 -5°C
-15°C
52°CCooling
21°CHeating
Outdoor unit operates over an outdoor temperature range of -5°C to 52°C for cooling and -15°C to 21°C for heating.
50 to 130%
Connectable capacity of indoor units for one outdoor unit
High capacity connectionLong piping system design
Design Versatility
•Equivalent pipe length: 120m maximum.•Total pipe length: 200m maximum.
*When outdoor unit is located above indoor unit. When outdoor unit is located below the indoor unit the height difference is 40m maximum.
Height difference
50m max.
Actual pipe length
100m max.
Height difference
15m max.
One outdoor unit can control up to 16 indoor units (28kW) of different types and capacities.
Diagram
Flow of refrigerantPower accumulation
technology
Comp.3
Comp.2
Comp.1
MAX Connectable indoor unit
16
Oil recovery operation
After a fixed period of time the oil recovery operation automatically returns accumulated oil found in the refrigerant circuit and indoor units.
Indoor Unit: Each indoor unit operates independently from the others and is, therefore, not affected by a failure within any part of the network.
103102
Operation display
Easy Maintenance
By indicating the operating status and details of failures on a PCB in the outdoor unit, better service and quick and easy maintenance are possible.
Operating display
Pump down can be performed from the outdoor unit using the switch on the PCB.
Pump down control
A pull-out plate ensures easy compressor replacement if necessary.
Easy replacement
The outdoor unit can be lifted by crane and set down on the building roof.
Craning into place
Four-direction piping allows a variety of installation configurations. Easy installation and pipe direction setting.
Four-direction pipe
Easy Installation
Space saving
Space saving by setting side by side without space in between. 5.72Setting size
(Unit: m2)
Installation space
Top air outlet
Back sideintake port
Front sideintake port
L2L1
300mm or more
500mmor more
FRONTSIDE
10mm or more
300mmor more
1Front 2
Bottom
3Right
4Back
Protective boards
Dimensions
650
1,38
0
1,300
(Unit : mm)
800
1,500
1,05
0
Outdoor unit goes into elevator
Easy wiringTransmission line
PCcontroller
Central remote controller
Outdoor unit
TransmissionadaptorTransmission line
Indoor unit
There is no height restriction for the side wall. The height(H) of front and rear wall should be less than1,200mm. If the height of wall exceeds 1,200mm by h mm, add h mm to the service space width for L1 and L2.H 1,200 : L1 500, L2 300 H 1,200 + h : L1 500 + h, L2 300 + h
(Unit : mm)
Transmission line:Non-polar 2-conductor transmission line prevents erroneous wiring.
Power supply wiring:Power supply for outdoor and indoor units is different.
•Outdoor unit 3Ø 4W 380 - 415V 50Hz•Indoor unit: 1Ø 2W 220 - 240V 50Hz
hH
(120
0mm
)
hH
(120
0mm
)
10mm or more
10mm or more
10mmor more
10mmor more
10mmor more
500mmor more
FRONTSIDE
For individually For continuous
HPRating Capacity range
m3/h
kW
kW
mm
mmmmmm
˚C
W/W
dB(A)
kW
Capacity
Power source
kW
kgkg
CoolingHeatingCoolingHeatingCoolingHeatingHigh
CoolingMaximum Connectable Indoor UnitIndoor unit connectable capacity
Input power
EERCOPAir flow rate
Dimensions
WeightRefrigerant chargeConnection pipe diameterOperation range
Sound pressure levelCompressor motor outputHeat exchanger fin
HeightWidthDepth
LiquidGasCoolingHeating
10
AO90MPCMF
1614 to 36.4
3 phase, 380 - 415V, 50Hz28.031.59.4010.02.983.15
9,8005751
1.5 / 3.4 / 5.0Plate fin coil
1,3801,30065030511.8
ø12.70Discharge Gas ø19.05 / Suction Gas ø28.58
-5 to 52-15 to 21
Model name
Normal operation modeSilent operation mode
Specifications
Outdoor units specifications
Note : Specifications are based on the following conditions.Cooling : Indoor temperature of 27˚CDB / 19˚CWB, and outdoor temperature of 35˚CDB / 24˚CWB.Heating : Indoor temperature of 20˚CDB / (15˚CWB), and outdoor temperature of 7˚CDB / 6˚CWB.
Dimensions (Unit : mm)Model: AO90MPCMF
1000mm(Boltpitch)850mm
678m
m
650mm703mm
1300mm
1380
mm
105104
Indoor units lineup 10 Types, 45 Models, Capacity range from 2.2 kW to 17.0 kW Indoor units of S series.
Compact Cassette
Cassette
High Static Pressure Duct
Duct
Floor / Ceiling
Ceiling
Wall Mounted
2.802.20Capacity range (kW)Model code
3.60 4.05 5.30 5.70 6.80 8.807.05 10.5 12.7 14.1 17.097 12 14 18 20 24 3025 36 45 54 60
Slim Type
AUXB07LATF AUXB09LATF AUXB12LATF AUXB18LATFAUXB14LATF
ARXB07LALF ARXB09LALF ARXB12LALF ARXB18LALFARXB14LALF
ABYA12LATF ABYA18LATFABYA14LATF
AWYA07LATF AWYA09LATF AWYA14LATFAWYA12LATF
ASYA18LATF
AWYA18LATF
ABYA24LATF
AUYA20LATF AUYA30LATFAUYA25LATF AUYA36LATF AUYA45LATF
ARXB30LATFARXB25LATF ARXB36LATF ARXB45LATF
ARXA30LATFARXA25LATF ARXA36LATF ARXA45LATF
ARXC36LATF ARXC45LATF ARXC60LATF
AUYA54LATF
ABYA30LATF
AWYA24LATF AWYA30LATF
ASYA24LATF ASYA30LATF
ABYA36LATF ABYA45LATF ABYA54LATF
Ceiling Wall
Low Static Pressure Duct
Silent model
Compact DuctSilent model
107106
Indoor units specifications
Compact Cassette Compact DuctLow Static Pressure DuctDuct
Cassette
Model name
Note : Specifications are based on the following conditions.Cooling : Indoor temperature of 27˚CDB / 19˚CWB, and outdoor temperature of 35˚CDB / 24˚CWB.Heating : Indoor temperature of 20˚CDB / (15˚CWB), and outdoor temperature of 7˚CDB / 6˚CWB.Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m.Voltage : 230 [V]; Standard static pressure : 0 Pa(ARXB07LALF,ARXB09LALF,ARXB12LALF,ARXB18LALF,ARXB25LATF,ARXB30LATF,ARXB36LATF,ARXB45LATF)Voltage : 230 [V]; Standard static pressure :100 Pa(ARXA25LATF,ARXA30LATF,ARXA36LATF,ARXA45LATF)
Model name
Note : Specifications are based on the following conditions.Cooling : Indoor temperature of 27˚CDB / 19˚CWB, and outdoor temperature of 35˚CDB / 24˚CWB.Heating : Indoor temperature of 20˚CDB / (15˚CWB), and outdoor temperature of 7˚CDB / 6˚CWB.Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m.Voltage : 230 [V].
Model name
Note : Specifications are based on the following conditions.Cooling : Indoor temperature of 27˚CDB / 19˚CWB, and outdoor temperature of 35˚CDB / 24˚CWB.Heating : Indoor temperature of 20˚CDB / (15˚CWB), and outdoor temperature of 7˚CDB / 6˚CWB.Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m.Voltage : 230 [V]; Standard static pressure : 100 Pa (ARXC36LATF, ARXC45LATF, ARXC60LATF).
Model name
Note : Specifications are based on the following conditions.Cooling : Indoor temperature of 27˚CDB / 19˚CWB, and outdoor temperature of 35˚CDB / 24˚CWB.Heating : Indoor temperature of 20˚CDB / (15˚CWB), and outdoor temperature of 7˚CDB / 6˚CWB.Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m.Voltage : 230 [V].
High Static Pressure Duct
2.202.5031.2330300270
0 to 50292724
217x663x59518
ø6.35ø12.7
ARXB07LALF
ARXB09LALF
ARXB12LALF
ARXB18LALF
ARXB14LALF
CoolingHeating
HighMedLow
HighMedLow
Liquid (Flare)Gas (Flare)
2.803.2032.6370340310
0 to 50312927
217x663x59518
ø6.35ø12.7
4.004.8063.0610550470
0 to 50312926
217x953x59525
ø6.35ø12.7
5.305.60
103.0950790620
0 to 50403530
217x953x59525
ø9.52ø15.88
3.604.1055.0560500420
0 to 50302825
217x953x59525
ø6.35ø12.7
kW
W
m3/ h
Pa
dB(A)
mm
mm
kg
Power source
Capacity
Input power
Airflow rate
Static pressure range
Sound pressure level
Dimensions (H x W x D)WeightConnectionpipe diameter
7.007.70155
1,090970870
0 to 80292624
270x1,135x70043
ø9.52ø15.88
ARXB25LATF
ARXB30LATF
ARXB36LATF
ARXA25LATF
ARXA30LATF
ARXA36LATF
ARXA45LATF
ARXB45LATF
8.809.50171
1,2001,090970
0 to 80312826
270x1,135x70043
ø9.52ø15.88
12.714.3246
1,5801,4501,3200 to 80
373533
270x1,135x70045
ø9.52ø19.05
7.007.70161
1,1001,000900
30 to 150383634
270x1,135x70043
ø9.52ø15.88
8.809.50172
1,4001,3001,200
30 to 150403836
270x1,135x70043
ø9.52ø15.88
10.512.7220
1,7501,6501,550
30 to 150434139
270x1,135x70043
ø9.52ø19.05
12.714.3312
1,8001,6001,500
30 to 150444240
270x1,135x70045
ø9.52ø19.05
10.512.7216
1,4401,2701,160
0 to 80353230
270x1,135x70043
ø9.52ø19.05
230V~ , 50HzCoolingHeating
HighMedLowHighMedLow
Liquid (Flare)Gas (Flare)
kW
W
m3/ h
dB(A)
mm
mm
kg
Power source
Capacity
Input power
Airflow rate
Sound pressure level
Dimensions (H x W x D)WeightConnectionpipe diameterDecoration Panel
CoolingHeating
HighMedLow
HighMedLow
Liquid (Flare)Gas (Flare)
kW
W
m3/ h
Pa
dB(A)
mm
mm
kg
Power source
Capacity
Input power
Airflow rate
Static pressure range
Sound pressure level
Dimensions (H x W x D)WeightConnectionpipe diameter
CoolingHeating
HighMedLowHighMedLow
(Main body)(With Panel)
Liquid (Flare)Gas (Flare)
kW
W
m3/ h
dB(A)
mm
mm
kg
Power source
Capacity
Input power
Airflow rate
Sound pressure level
Dimensions (H x W x D)
WeightConnectionpipe diameter
2.20 2.5028530480410383531
230 x 570 x 57018
ø6.35ø12.7
AUXB07LATF AUXB09LATF AUXB12LATF AUXB18LATFAUXB14LATF
2.803.2028530480410383531
230 x 570 x 57018
ø6.35ø12.7
4.004.5052580520460413734
230 x 570 x 57018
ø6.35ø12.7
5.005.4550
640540470443835
230 x 570 x 57018
ø9.52ø15.88
230V~ , 50Hz 3.604.1052580520460413734
230 x 570 x 57018
ø6.35ø12.7
UTG-UDYD-W (Option)
5.705.80104
1,000840700413733
246 x 830 x 830265 x 940 x 940
34ø9.52
ø15.88
7.057.85124
1,100940780434035
246 x 830 x 830265 x 940 x 940
34ø9.52ø15.88
10.512.7175
1,5001,3001,100
4742.538
296 x 830 x 830315 x 940 x 940
40ø9.52
ø19.05
12.713.7190
1,5501,3501,10048.54641
296 x 830 x 830315 x 940 x 940
40ø9.52ø19.05
14.115.8219
1,7001,4201,20051.547.543.5
296 x 830 x 830315 x 940 x 940
40ø9.52
ø19.05
8.809.10140
1,2501,050840464337
246 x 830 x 830265 x 940 x 940
34ø9.52
ø15.88
AUYA20LATF AUYA25LATF AUYA30LATF AUYA45LATF AUYA36LATF AUYA54LATF
230V~ , 50Hz 10.5 12.7 405
2,5001,9501,450
100 to 200453832
400 x 1,050 x 50045
ø9.52(Flare)ø19.05 (Flare)
17.018.2427
3,5003,0002,460
100 to 250494542
400 x 1,050 x 50050
ø9.52(Flare)ø19.05 (Flare)
230V~ , 50Hz 12.714.3427
3,5003,0002,460
100 to 250494542
400 x 1,050 x 50045
ø9.52 (Flare)ø19.05 (Flare)
ARXC36LATF ARXC45LATF ARXC60LATF
109108
Indoor units specifications
Floor / Ceiling
Ceiling
Model name
Note : Specifications are based on the following conditions.Cooling : Indoor temperature of 27˚CDB / 19˚CWB, and outdoor temperature of 35˚CDB / 24˚CWB.Heating : Indoor temperature of 20˚CDB / (15˚CWB), and outdoor temperature of 7˚CDB / 6˚CWB.Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m.Voltage : 230 [V].
ABYA12LATF ABYA14LATF ABYA18LATF ABYA24LATF
Model name
Note : Specifications are based on the following conditions.Cooling : Indoor temperature of 27˚CDB / 19˚CWB, and outdoor temperature of 35˚CDB / 24˚CWB.Heating : Indoor temperature of 20˚CDB / (15˚CWB), and outdoor temperature of 7˚CDB / 6˚CWB.Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m.Voltage : 230 [V].
ABYA30LATF ABYA36LATF ABYA45LATF ABYA54LATF
Model name ASYA18LATF ASYA24LATF ASYA30LATF
Model name
Note : Specifications are based on the following conditions.Cooling : Indoor temperature of 27˚CDB / 19˚CWB, and outdoor temperature of 35˚CDB / 24˚CWB.Heating : Indoor temperature of 20˚CDB / (15˚CWB), and outdoor temperature of 7˚CDB / 6˚CWB.Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m.Voltage : 230 [V].
AWYA09LATFAWYA07LATF AWYA12LATF AWYA18LATFAWYA14LATF AWYA24LATF AWYA30LATF
Wall Mounted
CoolingHeating
HighMedLowHighMedLow
Liquid (Flare)Gas (Flare)
kW
W
m3/ h
dB(A)
mm
mm
kg
Power source
Capacity
Input power
Airflow rate
Sound pressure level
Dimensions (H x W x D)WeightConnectionpipe diameter
3.604.1057
640560480403734
199 x 990 x 65528
ø6.35ø12.7
4.055.0057
640560480403734
199 x 990 x 65528
ø6.35ø12.7
5.305.6088
78065055046
41.537
199 x 990 x 65528
ø9.52ø15.88
6.607.7088880740630484541
199 x 990 x 65528
ø9.52ø15.88
230V~ , 50Hz
CoolingHeating
HighMedLowHighMedLow
Liquid (Flare)Gas (Flare)
kW
W
m3/ h
dB(A)
mm
mm
kg
Power source
Capacity
Input power
Airflow rate
Sound pressure level
Dimensions (H x W x D)WeightConnectionpipe diameter
8.809.10124
1,4501,280980423935
240 x 1,660 x 70048
ø9.52ø15.88
10.512.7144
1,6601,5001,270
454237
240 x 1,660 x 70048
ø9.52ø19.05
12.713.7160
1,8501,6601,430
484641
240 x 1,660 x 70048
ø9.52ø19.05
14.115.8180
2,2002,0001,800
525046
240 x 1,660 x 70048
ø9.52ø19.05
230V~ , 50Hz
CoolingHeating
HighMedLowHighMedLow
Liquid (Flare)Gas (Flare)
kW
W
m3/ h
dB(A)
mm
mm
kg
Power source
Capacity
Input power
Airflow rate
Sound pressure level
Dimensions (H x W x D)WeightConnectionpipe diameter
5.405.6038
80065055041
36.533
320 x 1,120 x 22016
ø9.52ø15.88
6.907.8050
970870750454137
320 x 1,120 x 22016
ø9.52ø15.88
8.008.8060
1,04091073047.544
39.5320 x 1,120 x 220
16ø9.52ø15.88
230V~ , 50Hz
Ceiling Wall
CoolingHeating
HighMedLowHighMedLow
Liquid (Flare)Gas (Flare)
kW
W
m3/ h
dB(A)
mm
mm
kg
Power source
Capacity
Input power
Airflow rate
Sound pressure level
Dimensions (H x W x D)WeightConnectionpipe diameter
230V~ , 50Hz2.202.5016
380330290343230
270 x 1,150 x 28516
ø6.35ø12.7
2.803.2019
480420390353230
270 x 1,150 x 28516
ø6.35ø9.52
3.604.1020
600520470353331
270 x 1,150 x 28516
ø6.35ø12.7
5.405.6030
760660560403734
270 x 1,150 x 28516
ø9.52ø15.88
6.907.8040
900780650444137
270 x 1,150 x 28516
ø9.52ø15.88
8.008.8050
950870780474542
270 x 1,150 x 28516
ø9.52ø15.88
4.304.9021
650570490373532
270 x 1,150 x 28516
ø6.35ø12.7
111110
Noi
se le
vel
Time
(4~6HP)
Rated noise value
-5dB ~ -6dB
Low noise mode
High Energy Saving
Advanced high efficiency technology
High seasonal efficiency
Our advanced high-efficiency technology achieves high performance within the actual usage performance range (50% load).
Large propeller fan :High performance and low noise realized by large propeller and optimization of angle.
DC fan motor :Miniaturized, low noise, high efficiency, multi-stage DC fan motor is mounted.
Large heat exchanger : Heat exchange performance is substan-tially improved by mounting of 3-row large heat exchanger.
DC inverter control :Efficiency is improved by mounting of new active filter module.
Subcool heat exchanger :Cooling performance is improved by mounting of dual tube heat exchanger.
DC twin rotary compressor :Efficiency in all load regions is good. Especially good performance from low to medium at normal operation.
100%
50%
0 COPCOPEEREER0
Cooling part loadCooling part load Heating part loadHeating part loadCooling EER
66% increase !
Heating COP
46% increase !
3.45 3.95
5.735.73 5.755.75Conditions : Connected indoor units: AUXD30LALH+AUXD24LALHCooling : indoor temp. of 27°CDB / 19°CWB, outdoor temp. of 35°CDB / 24°CWBHeating : indoor temp. of 20°CDB / 15°CWB, outdoor temp. of 7°CDB / 6°CWB*1. The data refers to a 6HP class outdoor unit.
*1 *1
More Comfort
Powerful Heating
Heating capacity is improved at low outdoor temperature by our advanced technology.
Low Noise Design
Low noise design of outdoor unitSignificantly reduced noise by optimized airflow structure design of outdoor unit.Low noise modeOutdoor unit can be switched to silent mode, depending on the installation environment.
Fujitsu General provides air conditioning systems for a wide range of applications from small office buildings and stores to large houses.
Heat pumpAJYA36LALH AJYA45LALH AJYA54LALH
Economy operationRoom temperature set point limitation
Various Energy Saving Function
The minimum and maximum temperature range can be set. The temperature setting is offset automatically over a certain period of time.
Heating Cooling
OriginalSet Temp.
Set point limitation setting
30
28
26
24
22
20
18
16
14
12
10
Cooling Set Temperature
Economy operationControl Temperature
Heating Set Temperature
Economy operationControl Temperature
Set Temp.
MAX. -4°C
MAX. +2°C
Economy operation
UpUp
Economy operation
Set Temp.
DownDown
DownDown
Capacity save operation The power consumption at peak is cut down.
(°C)
Various Comfort Control Function
Easy auto changeover functionAt the auto mode, cooling and heating mode is switched automatically to maintain the setting temperature.
Non-stop oil recovery operationThe product continues to operate without stopping the cooling or heating operation during oil recovery modes
Auto louver grill (Option for Slim Duct)
Auto louver grille provides comfort and efficient heating with louver controlled ductable outlet .
7
Current model (6HP class)
16.6
J-II series (6HP)
Outdoor temperature (°C)-20 -10 0
40
30
15 m20
25
35
Tem
pera
ture
(°C
)
Heating capacity (kW)
33%UP !
113112
3 7 1 0 2 4 5 6
Easy to connect with V-II communication systemIt is possible to connect directly with the transmission cable of the V-II system without convertor.
J-II system V-II system
Connects without a converter
Automatic address setting function : The address of each indoor unit can be automatically set by button switch of outdoor unit.
Connection check function : Possible to confirm whether wiring connection and address setting are correct by check run function for a short time.
Press the push buttonof outdoor unit.
• Display connected indoor unit numbers• Duplicately set address number of
indoor unit can be displayed
More Design Flexibility
Long Piping Length
High Capacity Connection
Our advanced refrigerant control technology allows us to achieve a total refrigerant piping length of 180 m. This opens up new possibilities in system design.
Easy Installation
Easier Installation
Our advanced refrigerant control technology allows us to achieve a total refrigerant piping length of 180 m. This opens up new possibilities in system design.
Convenient Commissioning Support
CoolingCooling46°C
21°C
-5°C -5°C
-20°C -20°C
Heating
(°C)
-20°C areaOperation possiblein heating.
50
40
30
20
10
0
-10
-20
Number of connectable indoor unit
Wide operating range
Installation in extreme temperature conditions is possible due to an increase in operational range.Cooling : -5°C~46°CHeating : -20°C~21°C
12 types, 52 modelsIndoor unit
Connectable indoor unit capacity range
130 % max.
Easy piping connection : Improvement of the reliability by decreasing the flare connection.
Easy wiring connection• Decreasing wiring mistakes by using non-polar 2 wires. (Remote
controller cable is 3 wires)• Improvement of wiring installation by common with V-II power supply
method.
Flexible installation of outdoor unit : Corresponds to the outdoor unit concentration installation.
Reduced installation intervals by front access
Flexible installation by 4 way pipe direction
Flare connection
Terminal box
J-II series
Power supply cable
Power supply (Indoor )
Power supply(Outdoor )
Height difference between outdoor and indoor units
180m max.
Total pipe length
30m max.
Height difference between indoor and indoor units
15m max.
Actual piping length
120m max.
Piping length from first separation tube to the farthest indoor unit
40m max.
4 HP2 to 6
units
5 HP2 to 8
units
6 HP2 to 9
units
Flare connection
EV kitPrevious model
115114
Easy Maintenance
Design for Easy Maintenance
Easy to read 7-segment LED : Confirm detail operational and trouble status without using specific equipment
Trouble diagnosis by Service Tool
Connection to Service Tool• Detail operation status and recent error history can be
checked and analyzed by using Service Tool.• Last 5 min. operation memory can be also recorded.
Emergency Stop Function
Specifications
Outdoor units specifications
Dimensions (Unit : mm)Model: AJYA36LALH / AJYA45LALH / AJYA54LALH
Note : Specifications are based on the following conditions.Cooling : Indoor temperature of 27°CDB / 19°CWB, and outdoor temperature of 35°CDB / 24°CWB.Heating : Indoor temperature of 20°CDB / (15°CWB), and outdoor temperature of 7°CDB / 6°CWB.Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m.The protective function might work when using it outside the operation range.
HPRating Capacity range
m3/h
kW
kW
mm
mmmmmm
˚C
W/W
dB(A)
kW
Capacity
Power source
kW
kgkg
CoolingHeatingCoolingHeatingCoolingHeatingHighCoolingHeating
CoolingMaximum Connectable Indoor UnitIndoor unit connectable capacity
Input power
EERCOPAir flow rate
Dimensions
WeightRefrigerant chargeConnection pipe diameterOperation range
Sound pressure levelCompressor motor outputHeat exchanger fin
HeightWidthDepth
LiquidGasCoolingHeating
Model name
5
AJYA45LALH
6
AJYA54LALH
65.6 to 14.5
Single-phase, ~230V, 50Hz11.212.52.802.764.004.53
6,2005052
3.75Blue fin1,3349703701174.8
ø9.52ø15.88-5 to 46
-20 to 21
87.0 to 18.2
Single-phase, ~230V, 50Hz14.016.03.893.813.604.20
6,4005153
3.75Blue fin1,3349703701175.3
ø9.52ø15.88-5 to 46
-20 to 21
97.8 to 20.1
Single-phase, ~230V, 50Hz15.518.04.494.563.453.95
6,9005355
3.75Blue fin1,3349703701175.3
ø9.52ø19.05-5 to 46
-20 to 21
4
AJYA36LALH
Emergencystop function
SU MO TU WE TH FR SA
Wired Remote Controller
Simple Remote Controller
Error status can be checked easily via the indoor unit wired controller. An error code is displayed on a liquid crystal screen.
Faulty unit number (Remote controller address)Error code
Remote controller address
Error code
Movable PCB panelEasier for maintenance work behind the PCB
7-segment LED
Emergency alarm can be received by indoor, outdoor units, Central Remote Controller or Touch Panel Controller when they received it, all units will be stopped.
Touch Panel Controller
CentralRemote Controller
or
Emergencystop function
Emergencystop function
T h P l
Central
Note : In case of received Emergency alarm by Indoor / outdoor unit : All units connected within same refrigerant system will be stopped. Central Remote Controller or Touch Panel Controller : all units connected within VRF network system with Central Remote Controller or Touch Panel Controller will be stopped.
Equipment Detail (Diagram)
Transmission cable (Non-polar 2 wires)
Service ToolUTY-ASGXUSB adaptor (Field supplied)
Software
Detail
650
970 32 12370
Terminal blocks (Transmission)
Terminal blocks (Power)
3-Way valve (Liquid)
3-Way valve (Gas)
Ø28 (Cable port)
Pipe portPipe port
Pipe & cable port
Pipe port89
50438
622
65 15
1450
21 55 21 65
166
370
43(L
iquid)
51(G
as)
(410
)40
3213
34
907
297
(Gas
valve
)
279
5095 12
050 50
25
87131
(Liqu
id va
lve)
1000
111
70
155
14221
227
305
341
154
36
Ø28 (Cable port)Ø28 (Cable port)
Ø28 (Cable port)Ø28 (Cable port)
AA
Ø28 (Cable port)
117116
4-face heat exchanger: Heat exchange efficiency is significantly improved by the introduction of a new 4-face heat exchanger that increases effective surface area.
In multiple outdoor unit installations, the unique front intake design improves airflow into the Heat Exchanger.
High Efficiency
Energy saving technology that boosted operation efficiency
Significantly improved EER/COP
Significantly greater efficiency is realized by the use of a DC twin rotary compressor, inverter technology, and large heat exchanger.
DC Fan motor: Power consumption has been reduced by 25% compared to previous models by using a compact and high performance DC fan motor.
Choice of space saving or energy efficiency combinations
Energy Efficiency Combination
Various Energy Saving FeaturesV series
V-IIseries
V-II series
3.0 3.50 4.0 COPCOPEEREER3.0 3.50 4.0
CoolingCooling HeatingHeatingCooling EER
27% increase!
Surface area
1.7 times!
Heating COP
18% increase!
3.2 3.7
4.074.07 4.374.37* “EER/COP” is the coefficient of performance [ = capacity (kW) ÷ input power (kW) ].*EER/COP values are based on our own testing method.*1. The data refers to a 8HP outdoor unit.
Sine-wave DC inverter control:High efficiency operation is realized by using a sine wave DC inverter control.
DC twin rotary compressor: Significantly greater efficiency is realized by use of a large capacity DC twin rotary compressor with substantially increased refrigerant intake and compression efficiency.
Previousmodel
For 16HP
[ Space saving combination ] [ Energy efficiency combination ]
18%energy saving !
For 24HP
12%energy saving !
For 28HP
10%energy saving !
16HP
12HP 12HP
12HP 8HP 8HP
8HP 8HP
8HP 8HP 8HP
12HP16HP
(Comparison of Average COP)
Smart and cutting edge designExtensive lineup from 8HP to 48HP in 2HP incrementConnectable indoor unit capacity ratio up to 150%
*1 *1
8, 10, 12HP 14, 16HP
Economy operation
Economy operation can be set by remote controller.The temperature setting is offset automatically over a certain period of time.
Room temperature set point limitation
The minimum and maximum temperature range can be set giving further energy saving while considering the comfort of the occupants.
Peak cut operation
Operation capacity can be set in 4 steps for rated capability. The power consumption at peak is cut down and the maximum load is suppressed.
Auto-off timer
Each remote controller is equipped with an OFF timer function that automatically stops operation when a fixed time has elapsed from the start of operation. This prevents waste of energy. (Note: Except simple remote controller)
Cooling Set Temperature
Economy operationControl Temperature
Heating Set Temperature
Economy operationControl Temperature
Set Temp.
MAX. -4°C
MAX. +2°C
Economy operation
UpUp
Economy operation
Set Temp.Down
DownDown
Down
Heating set temp. range
Cooling set temp. range
Heating Cooling
Original Settemp. limitation
Set pointlimitation setting
°C3028262422201816141210
Operation setting (System Controller)
W
Capacity
Time
Settinglevel
Peak cutControl device
Signal input
119118
Design Versatility
High static pressure of 80Pa
Overall piping length 1,000m Space saving and compact size
The outdoor unit can have a condenser hood easily connected with a static pressure of 80Pa standard. This allows outdoor units to be installed within plant rooms in high rise buildings.
World’s top class overall piping length of 1,000m allows for application in a wide variety buildings.
Compact size has been achieved by significantly reducing the width of the outdoor units compared to previous models.
Large diameter fan and DC motor has been utilized allowing an external static pressure of 80Pa. This is approximately 2.6 times greater than the previous model.
Installation Example
80Paas standard
60m max.
Pipe length from first separation tube to the farthest indoor unit
50m max.
Height difference between outdoor and indoor units
15m max.
Height difference between indoor and indoor units
150m max.
Actual pipe length
Connectable indoor unit number
up to 48Wide variation of indoor units
12 types, 55 models
Connectable indoor unit capacity
Ratio up to 150%
Installation in extreme temperature conditions is possible due to an increase in operational range.Cooling : -15°C~46°CHeating : -20°C~21°C
Wide operating range
Various combination from 8HP to 48HP with 2HP increments. 12 types, 55 models of indoor units can be selected ranging from 2.2kW to 25kW in capacity. A maximum of 150% indoor unit connectable capacity.
High capacity connection
V series10HP
V-II series10HP
52% reduction
28% reduction
CoolingCooling46°C
21°C
-15°C -15°C -20°C -20°C
Heating
(°C)
-15°C areaOperation possiblein cooling.
-20°C areaOperation possiblein heating.
50
40
30
20
10
0
-10
-20
*1
Note : when indoor unit connected capacity is greater than 100%, individual indoor units will operate at a slightly lower capacity when maximum capacity is required.
*1 Note : When a multiple outdoor unit connection is used, operating range is from -5°C to 46°C in cooling.
Previous model V-II series
Powerful discharge with an external static pressure of 80Pa.
For the outdoor unit stated below : 40m max.
1,000m max.
Total pipe length
For 160HP
16HP(8HP×2)×10=160HP
38.0m2
V series
16HP×10=160HP
16.2m2
V-II series 57% space saving
1,300mm 930mm
V series16HP (8HP x2)
V-II series16HP
2,600mm 1,240mm
121120
High Reliability Easy Installation
Life-extending operation
DDDDCCC11
AC4
DC2
AACCC55
DC3
DC1
AC4
DC2
AACCC55
DDDCCCCCCCCDDDDDD333333
DC1
AC4
DDDCCC222
AACCC55
DC3
Rotation Rotation
Rotation
Outdoor unit operation rotationThe compressor starting order is rotated so that the running time is shared.
Easily transported
Failure
Indoor unit continuous operationEach indoor unit is controlled individually on the system network. This allows all indoor units to continue to operate unaffected even if an error should occur at any indoor unit’s on the VRF network system.
Corrosion resistant of the heat exchanger has been improved by the introduction of blue fin treatment to the outdoor unit’s heat exchanger.
If one of two compressors malfunctions, it will not affect the operation of the remaining outdoor units.
Outdoor UnitsIf one of compressors fails, backup operation will be performed by the remaining compressors as emergency.
Installation is made easier as the communications wiring can be connected continuously to any component.
The need for a oil equalization pipe as required on the previous model has been removed. The installation costs have been reduced by employing a simple 2 pipe connection
Backup operation
The Web Monitoring system allows you view system operation at all times over the internet ensuring trouble free operation.
The operating VRF network system in the building can be monitored in real time over the Internet.
Remote monitoringAdoption of blue fin heat exchanger
Internetor
Public Telephone Line
Monitoring Side
Indoor unit
Transmission line
Outdoor unit
Simple wiring methodOther wiring method
Simple signal line connection
Design of outdoor unit allows for lifting straps to be used
Web Monitoring Tool
USB adaptor(Field supplied)
Easy access
Expansion of work space
By adopting a L-Shape front panel that can be removed, the work space for installation and service has been significantly expanded by this new design. For multiple installations, work is performed easily and efficiently even in a narrow space.
Automatic addresssetting is performedat outdoor unit
Automatic address setting
Addresses are automaticallydistributed from outdoor unit.
Manual address setting from indoor unit and remote controller is also possible.
3 7 1 0
2 4 5 6
The address of each indoor unit can be automatically set by button switch of outdoor unit.
Up to maximum length 3,600m
Eliminating oil equalization pipe
Easy piping connection
VRF Network System Side
Hydrophilic coating
Cobalt Blue protectionStandard chromate protectionAluminium base material
Blue fin heat exchanger
Note: The inverter compressors start in priority.Rotate operation is alternated by the start / stop timing of the compressors
20% weight reduction(Than Previous model) Note:
In the case of 14HP
Light weight
Easily craned into position using lifting belt hooks
Transporting by forklift
Can be transported in a small elevator
V-II series
Press the pushbutton switch of outdoor unit.
Note: In a multiple refrigerant system installation, Automatic addressing sequence cannot be initiated
123122
Compressor compartment
Low noise design: Compressor noise has been significantly reduced by shielding the compressor compartment.
Indoor unit: Low noise indoor unit lineup
Auto changeover setting allows for the product to easily switch between cooling and heating modes regardless of the operation mode of other indoor units. This can be done via specific indoor unit with wired remote controller. This ensures comfortable operation all year round.
Switching to cooling and heating mode by specific remote controller in the main room, etc.
A comfortable room condition is maintained during oil recoverymode because the product continues to operate without stopping the cooling or heating operation.
Auto changeover function
Non-stop oil recovery operation
Emergency alarm can be received by indoor, outdoor units or Touch Panel Controller when they received it, all units will be stopped.
Maintenance of electrical components, valves, and compressor parts from the front is possible.
Split front panel allows for maintenance from top or bottom of the outdoor unit
Easy-to-read 7-segment LED display which explains operational and trouble status
Note: In case of received Emergency alarm byIndoor/outdoor unit: All units connected within same refrigerant system will be stopped. Touch Panel Controller: all unit connected within VRF network system with Touch Panel Controller will be stopped.
Non-stop operation: When servicing a specific indoor unit, maintenance can be performed even without turning off the other indoor units.
Emergency stop function
Continuous operation during maintenance
ON OFF ON ON ON ON
Compact Duct
Slim Duct
Low Static Pressure Duct Compact Wall Mounted
Compact Cassette
Air conditioning load factor
Capacity
Operating sound
time
100%
58dB
0
0
Heat load
down
Quiet priority low noise mode
Quiet priority setting
Capacity priority low noise mode
time
100%
58dB
0
0Reset automatically
Alternatedautomatically
Capacity priority setting
Heat loadHeat loadHeat load
Previous model V-II series (Heating operation)
Time
ON
OFF
Operation stopped at oil recovery
Time
ON
Non-stop oil recovery operation
Wired Remote Controller Simple Remote ControllerError status can be checked easily via the indoor unit wired controller
Touch Panel Controller
Emergencystop function
Emergencystop function
Emergencystop function
vavalvalvalvalvalvvvevesfro
Comfort and Convenience
Quiet operation
Low noise mode:Two low noise modes can be selected automatically by quiet priority setting and capacity priority setting depending on the usage environment and outside temperature load.
Easy Service & Maintenance
Design for easy service and maintenance
Inspection and replacement of main parts is easier due to innovative construction and an LED operational display.
An error code is displayed on a liquid crystal screen.
Movable PCB panel that allows for easier maintenance work behind the PCB
Consolidated electrical components make maintenance easy
SU MO TU WE TH FR SA
Faulty unit number(Remote controller address)
Error code
Remote controller address
Error code
125124
Outdoor units lineup Outdoor units dimensions
Dimensions (Unit : mm)
8,10,12HP: AJYA72LALH / AJYA90LALH / AJY108LALH
14,16HP: AJY126LALH / AJY144LALH
8-12×17 (Hole)
1690
652.5
765
530 (Bolt pitch)80690 (Bolt pitch)
732 (
Bolt p
itch)
8-12×7 (Hole)
1690
765
732 (
Bolt p
itch)
1000 (Bolt pitch)840 (Bolt pitch)80
ø43.7
ø22.2Transmission cable port
Power supply cable portø61.3431
80
190
82
42
Pipe port
100
5373
7595
179
ø43.7
ø22.2
ø22.2
125
Pipe port
Power supply cable port
Transmission cable port
Transmission cable port
10
A
AB C
B Bottom side knockout positionCFront side knockout position Left side knockout positionTop view
Back view
Back view
Power supply cable port
Space saving combination
Energy efficiency combination
28.0kW (10HP)
44.8kW (16HP)
84.8kW (30HP) 89.8kW (32HP) 95.9kW (34HP) 102.4kW (36HP) 113.5kW (40HP)
120.0kW (42HP) 125.0kW (44HP)
67.2kW (24HP) 72.8kW (26HP) 78.3kW (28HP)62.4kW (22HP)
22.4kW (8HP)
•Combinations other than the followings are not recommended.
33.5kW (12HP) 40.0kW (14HP) 45.0kW (16HP)
50.4kW (18HP) 55.9kW (20HP) 61.5kW (22HP) 67.0kW (24HP) 73.5kW (26HP)
78.5kW (28HP) 85.0kW (30HP) 90.0kW (32HP) 95.0kW (34HP) 100.5kW (36HP)
107.0kW (38HP) 112.0kW (40HP) 118.5kW (42HP) 123.5kW (44HP) 130.0kW (46HP)
135.0kW (48HP)
AJY198LALHHUNIT : AJY126/A72LALH
AJY216LALHHUNIT : AJYA72/A72/A72LALH
AJY234LALHHUNIT : AJYA90/A72/A72LALH
AJY252LALHHUNIT : AJY108/A72/A72LALH
AJY144LALHHUNIT : AJYA72/A72LALH
AJY288LALHHUNIT : AJY108/108/A72LALH
AJY306LALHHUNIT : AJY126/108/A72LALH
AJY324LALHHUNIT : AJY126/126/A72LALH
AJY360LALHHUNIT : AJY126/126/108LALH
AJY270LALHHUNIT : AJY126/A72/A72LALH
AJY396LALHHUNIT : AJY144/126/126LALH
AJY378LALHHUNIT : AJY126/126/126LALH
AJYA90LALHUNIT : AJYA90LALH
AJY108LALHUNIT : AJY108LALH
AJY126LALHUNIT : AJY126LALH
AJY144LALHUNIT : AJY144LALH
AJYA72LALHUNIT : AJYA72LALH
AJY180LALHUNIT : AJY108/A72LALH
AJY198LALHUNIT : AJY108/A90LALH
AJY216LALHUNIT : AJY108/108LALH
AJY234LALHUNIT : AJY126/108LALH
AJY162LALHUNIT : AJYA90/A72LALH
AJY270LALHUNIT : AJY144/126LALH
AJY288LALHUNIT : AJY144/144LALH
AJY306LALHUNIT : AJY108/108/A90LALH
AJY324LALHUNIT : AJY108/108/108LALH
AJY252LALHUNIT : AJY144/108LALH
AJY360LALHUNIT : AJY144/108/108LALH
AJY378LALHUNIT : AJY144/126/108LALH
AJY396LALHUNIT : AJY144/144/108LALH
AJY414LALHUNIT : AJY144/144/126LALH
AJY342LALHUNIT : AJY126/108/108LALH
AJY432LALHUNIT : AJY144/144/144LALH
930
1240
127126
Outdoor units specifications
Energy Efficiency Combination
HPRating Capacity range
Space Saving Combination
m3/h
kW
kW
mm
mmmmmm
˚C
W/W
dB(A)
kW
Capacity
Power source
PakW
kgkg
CoolingHeatingCoolingHeatingCoolingHeatingHighCoolingHeating
Cooling
Unit 1Unit 2Unit 3
Model name
Maximum Connectable Indoor Unit*1
Indoor unit connectable capacity
Input power
EERCOPAir flow rate
Dimensions
WeightRefrigerant chargeConnection pipe diameterOperation range
Sound pressure level*2
Maximum external static pressureCompressor motor outputHeat exchanger fin
HeightWidthDepth
LiquidGasCoolingHeating
8
22.425.05.515.724.074.37
11,1005658803.9
Blue fin1,690930 76522011.2
12.7022.20
-15 to 46-20 to 21
1511.2-33.6
10
28.031.57.737.83 3.62 4.02
11,1005859803.9
Blue fin1,690 93076522011.2
12.7022.20
-15 to 46-20 to 21
1614.0-42.0
12
33.537.59.62 9.28 3.484.04
11,100586080
3.9 + 4.5Blue fin1,690 93076527511.8
12.7028.58
-15 to 46-20 to 21
1716.8-50.2
14
40.045.011.5311.453.473.93
13,000606180
3.9 + 4.5Blue fin1,690 1,24076529611.8
12.7028.58
-15 to 46-20 to 21
2120.0-60.0
16
45.050.0
14.1712.603.183.97
13,000616180
3.9 + 4.5Blue fin1,690 1,24076529611.8
12.7028.58
-15 to 46-20 to 21
2422.4-67.2
18
50.456.5
13.2413.55 3.81 4.17
11,100 x 2606280
3.9 x 2Blue fin1,690 930 x 2
765220 + 22011.2 x 215.8828.58
-5 to 46-20 to 21
3225.2-75.6
20
55.962.5
15.13 15.00 3.694.17
11,100 x 2606280
3.9 x 2 + 4.5Blue fin1,690
930 x 2765
275 + 22011.8 + 11.2
15.8828.58
-5 to 46-20 to 21
3228.0-83.9
22
61.569.0
17.35 17.11 3.54 4.03
11,100 x 2616380
3.9 x 2 + 4.5Blue fin1,690
930 x 2765
275 + 22011.8 + 11.2
15.8834.92
-5 to 46-20 to 21
3230.8-92.3
24
67.075.0
19.24 18.56 3.484.04
11,100 x 2616380
3.9 x 2 + 4.5 x 2Blue fin1,690
930 x 2765
275 + 27511.8 x 215.8834.92
-5 to 46-20 to 21
3533.5-100.5
36
100.5112.528.86 27.84 3.484.04
11,100 x 3636580
3.9 x 3 + 4.5 x 3Blue fin1,690 930 x 3
765275 + 275 + 275
11.8 x 319.0541.27
-5 to 46-20 to 21
4850.3-150.8
34
95.0106.526.97 26.39 3.524.04
11,100 x 3636480
3.9 x 3 + 4.5 x 2Blue fin1,690 930 x 3
765275 + 275 + 22011.8 x 2 + 11.2
19.0534.92
-5 to 46-20 to 21
4847.5-142.5
32
90.0100.028.3425.203.183.97
13,000 x 2646480
3.9 x 2 + 4.5 x 2Blue fin1,690
1,240 x 2 765
296 + 29611.8 x 219.0534.92
-5 to 46-20 to 21
4845.0-135.0
30
85.095.025.7024.053.313.95
13,000 x 2646480
3.9 x 2 + 4.5 x 2Blue fin1,690
1,240 x 2765
296 + 29611.8 x 219.0534.92
-5 to 46-20 to 21
4542.5-127.5
28
78.587.5
23.79 21.88 3.304.00
13,000 + 11,100636480
3.9 x 2 + 4.5 x 2Blue fin1,690
930 + 1,240765
296 + 27511.8 x 215.8834.92
-5 to 46-20 to 21
4239.3-117.8
26
73.582.5
21.15 20.73 3.483.98
13,000 + 11,100626480
3.9 x 2 + 4.5 x 2Blue fin1,690
930 + 1,240765
296 + 27511.8 x 215.8834.92
-5 to 46-20 to 21
3936.8-110.3
38
107.0120.030.77 30.01 3.484.00
13,000 + 11,100 × 2646580
3.9 x 3 + 4.5 x 3Blue fin1,690
930 x 2 + 1,240765
296 + 275 + 27511.8 x 319.0541.27
-5 to 46-20 to 21
4853.5-160.5
40
112.0125.033.41 31.16 3.354.01
13,000 + 11,100 × 2646580
3.9 x 3 + 4.5 x 3Blue fin1,690
930 x 2 + 1,240765
296 + 275 + 27511.8 x 319.0541.27
-5 to 46-20 to 21
4856.0-168.0
42
118.5132.535.32 33.33 3.363.98
13,000 × 2 + 11,100656580
3.9 x 3 + 4.5 x 3Blue fin1,690
930 + 1,240 x 2765
296 + 296 + 27511.8 x 319.0541.27
-5 to 46-20 to 21
4859.3-177.8
44
123.5137.537.96 34.48 3.253.99
13,000 × 2 + 11,100656580
3.9 x 3 + 4.5 x 3Blue fin1,690
930 + 1,240 x 2765
296 + 296 + 27511.8 x 319.0541.27
-5 to 46-20 to 21
4861.8-185.3
46
130.0145.039.8736.653.263.96
13,000 x 3656680
3.9 x 3 + 4.5 x 3Blue fin1,690
1,240 x 3765
296 + 296 + 29611.8 x 319.0541.27
-5 to 46-20 to 21
4865.0-195.0
48
135.0150.042.5137.803.183.97
13,000 x 3666680
3.9 x 3 + 4.5 x 3Blue fin1,690
1,240 x 3765
296 + 296 + 29611.8 x 319.0541.27
-5 to 46-20 to 21
4867.5-202.5
AJYA72LALHAJYA72LALH
AJYA90LALHAJYA90LALH
AJY108LALHAJY108LALH
AJY126LALHAJY126LALH
AJY144LALHAJY144LALH
AJY162LALHAJYA90LALHAJYA72LALH
AJY180LALHAJY108LALHAJYA72LALH
AJY198LALHAJY108LALHAJYA90LALH
AJY216LALHAJY108LALHAJY108LALH
AJY324LALHAJY108LALHAJY108LALHAJY108LALH
AJY306LALHAJY108LALHAJY108LALHAJYA90LALH
AJY288LALHAJY144LALHAJY144LALH
AJY270LALHAJY144LALHAJY126LALH
AJY252LALHAJY144LALHAJY108LALH
AJY234LALHAJY126LALHAJY108LALH
AJY342LALHAJY126LALHAJY108LALHAJY108LALH
AJY360LALHAJY144LALHAJY108LALHAJY108LALH
AJY378LALHAJY144LALHAJY126LALHAJY108LALH
AJY396LALHAJY144LALHAJY144LALHAJY108LALH
AJY414LALHAJY144LALHAJY144LALHAJY126LALH
AJY432LALHAJY144LALHAJY144LALHAJY144LALH
HPRating Capacity range
m3/h
kW
kW
mm
mmmmmm
˚C
W/W
dB(A)
kW
Capacity
Power source
PakW
kgkg
CoolingHeatingCoolingHeatingCoolingHeatingHighCoolingHeating
Cooling
Unit 1Unit 2Unit 3
Model name
Maximum Connectable Indoor Unit*1
Indoor unit connectable capacity
Input power
EERCOPAir flow rate
Dimensions
WeightRefrigerant chargeConnection pipe diameterOperation range
Sound pressure level*2
Maximum external static pressureCompressor motor outputHeat exchanger fin
HeightWidthDepth
LiquidGasCoolingHeating
16
44.850.011.0211.444.074.37
11,100 x 2595980
3.9 x 2Blue fin1,690 930 x 2
765220 + 22011.2 x 212.7028.58
-5 to 46-20 to 21
3022.4-67.2
22
62.470.017.0417.173.664.08
13,000 + 11,100616280
3.9 x 2 + 4.5Blue fin1,690
930 + 1,240765
296 + 22011.8 + 11.2
15.8834.92
-5 to 46-20 to 21
3331.2-93.6
24
67.275.0
16.5317.164.074.37
11,100 x 3616180
3.9 x 3Blue fin1,690
930 x 3765
220 + 220 + 22011.2 x 315.8834.92
-5 to 46-20 to 21
3633.6-100.8
26
72.881.5
18.7519.27 3.88 4.23
11,100 x 3626280
3.9 x 3Blue fin1,690
930 x 3765
220 + 220 + 22011.2 x 315.8834.92
-5 to 46-20 to 21
3936.4-109.2
28
78.387.5
20.64 20.72 3.794.22
11,100 x 3626380
3.9 x 3 + 4.5Blue fin1,690
930 x 3765
275 + 220 + 22011.8 + 11.2 x 2
15.8834.92
-5 to 46-20 to 21
4239.2-117.4
30
84.895.022.5522.893.764.15
13,000 + 11,000 x 2636380
3.9 x 3 + 4.5Blue fin1,690
930 x 2 + 1,240765
296 + 220 + 22011.8 + 11.2 x 2
19.0534.92
-5 to 46-20 to 21
4542.4-127.2
44
125.0140.037.2335.503.363.94
13,000 x 3656680
3.9 x 3 + 4.5 x 3Blue fin1,690
1,240 x 3765
296 + 296 + 29611.8 x 319.0541.27
-5 to 46-20 to 21
4862.5-187.5
42
120.0135.034.5934.353.473.93
13,000 x 3656680
3.9 x 3 + 4.5 x 3Blue fin1,690
1,240 x 3765
296 + 296 + 29611.8 x 319.0541.27
-5 to 46-20 to 21
4860.0-180.0
40
113.5127.532.68 32.18 3.473.96
13,000 x 2 + 11,100646580
3.9 x 3 + 4.5 x 3Blue fin1,690
930 + 1,240 x 2765
296 + 296 + 27511.8 x 319.0541.27
-5 to 46-20 to 21
4856.8-170.2
36
102.4115.028.5728.623.584.02
13,000 x 2 + 11,100646580
3.9 x 3 + 4.5 x 2Blue fin1,690
930 + 1,240 x 2765
296 + 296 + 22011.8 x 2 + 11.2
19.0541.27
-5 to 46-20 to 21
4851.2-153.6
34
95.9107.526.66 26.45 3.604.06
13,000 + 11,100 x 2636480
3.9 x 3 + 4.5 x 2Blue fin1,690
930 x 2 + 1,240765
296 + 275 + 22011.8 x 2 + 11.2
19.0534.92
-5 to 46-20 to 21
4848.0-143.8
32
89.4 100.0 24.75 24.28 3.61 4.12
11,100 x 3626480
3.9 × 3 + 4.5 × 2Blue fin1,690
930 × 3765
275 + 275 + 22011.8 × 2 + 11.2
19.0534.92
-5 to 46-20 to 21
4844.7-134.1
AJY144LALHHAJYA72LALHAJYA72LALH
AJY198LALHHAJY126LALHAJYA72LALH
AJY216LALHHAJYA72LALHAJYA72LALHAJYA72LALH
AJY234LALHHAJYA90LALHAJYA72LALHAJYA72LALH
AJY252LALHHAJY108LALHAJYA72LALHAJYA72LALH
AJY270LALHHAJY126LALHAJYA72LALHAJYA72LALH
AJY396LALHHAJY144LALHAJY126LALHAJY126LALH
AJY378LALHHAJY126LALHAJY126LALHAJY126LALH
AJY360LALHHAJY126LALHAJY126LALHAJY108LALH
AJY324LALHHAJY126LALHAJY126LALHAJYA72LALH
AJY306LALHHAJY126LALHAJY108LALHAJYA72LALH
AJY288LALHHAJY108LALHAJY108LALHAJYA72LALH
3-phase 4 wire, 400 V, 50Hz 3-phase 4 wire, 400 V, 50Hz
3-phase 4 wire, 400 V, 50Hz3-phase 4 wire, 400 V, 50Hz
Note : Specifications are based on the following conditions.Cooling : Indoor temperature of 27°CDB / 19°CWB, and outdoor temperature of 35°CDB / 24°CWB.Heating : Indoor temperature of 20°CDB / (15°CWB), and outdoor temperature of 7°CDB / 6°CWB.
Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m.When cooling operation will be conducted at outdoor air temperature below -5°C, the outdoor unit must be installed in a position that is higher than or equal to those of indoor units.
*1 Minimum connectable indoor unit number is 2. However ARXC72 and ARXC90 can be used signal connection.*2 The noise value is the value when measured in an anechoic room.
When measured in the actual installed state, surrounding noise and reflections are received and the measured value is usually larger than the indicated value.
129128
&
Indoor units lineup
Compact Cassette
Cassette
Compact Duct
Slim Duct(Drain pump internal)
Low Static Pressure Duct
High Static Pressure Duct
Duct
Floor / Ceiling
Ceiling
2.20Capacity range (kW)Model code
2.80 3.60 4.50 5.60 7.10 11.29.00 12.5 14.0 18.0 22.4 25.07 9 12 14 18 24 3630 45 54 60 72 90
AUXB07LALH AUXB09LALH AUXB12LALH AUXB14LALH AUXB18LALH
AUXD18LALH
ARXB07LALH ARXB09LALH ARXB12LALH ARXB14LALH
ASYE07LACH ASYE09LACH ASYE12LACH ASYE14LACH
ARXB18LALH
ASYA18LACH
ABYA12LBTH ABYA14LBTH ABYA18LBTH ABYA24LBTH
AUXD24LALH
AUXB24LALH
AUXA45LALHAUXA36LALH AUXA54LALH
ARXB30LATH
AUXA30LALH
ARXB24LATH ARXB36LATH ARXB45LATH
ARXA30LATHARXA24LATH ARXA36LATH ARXA45LATH
ARXC36LATH ARXC45LATH ARXC60LATH* ARXC72LATH* ARXC90LATH*
ABYA30LBTH ABYA36LBTH ABYA45LBTH ABYA54LBTH
Compact Wall Mounted(EEV internal)
Wall Mounted
Compact Wall Mounted(EEV external)
With this model, connection of EV kit is necessary.
ASYA07LACH ASYA09LACH ASYA12LACH ASYA14LACH
ARXD07LATH ARXD09LATH ARXD12LATH ARXD14LATH ARXD18LATH ARXD24LATH
ASYA30LACHASYA24LACH
*: ARXC60/72/90LATH can be connected to V-II series only.
131130
&
Indoor units specifications
Compact Cassette Compact DuctLow Static Duct & Duct
Cassette
Model name
Slim Duct(Drain pump internal)
Model name
Model name
Note : Specifications are based on the following conditions.Cooling : Indoor temperature of 27˚CDB / 19˚CWB, and outdoor temperature of 35˚CDB / 24˚CWB.Heating : Indoor temperature of 20˚CDB / (15˚CWB), and outdoor temperature of 7˚CDB / 6˚CWB.Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m.Voltage : 230 [V].
Model name
Note : Specifications are based on the following conditions.Cooling : Indoor temperature of 27˚CDB / 19˚CWB, and outdoor temperature of 35˚CDB / 24˚CWB.Heating : Indoor temperature of 20˚CDB / (15˚CWB), and outdoor temperature of 7˚CDB / 6˚CWB.Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m.
*: ARXC60/72/90LATH can be connected to V-II series only.
Model name
Note : Specifications are based on the following conditions.Cooling : Indoor temperature of 27˚CDB / 19˚CWB, and outdoor temperature of 35˚CDB / 24˚CWB.Heating : Indoor temperature of 20˚CDB / (15˚CWB), and outdoor temperature of 7˚CDB / 6˚CWB.Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m.Voltage : 230 [V].
High Static Pressure Duct
2.22.846
370310280
0 to 5025292624
2.22.844
550490440
0 to 9025282522
2.83.250
600550480
0 to 9025292624
3.64.054
600510450
0 to 9025302724
4.55.092
800710610
0 to 9025343228
5.66.383
940840750
0 to 9025343228
198 x 900 x 62023
7.18.0122
1,3301,2401,100
0 to 5025353229
198 x 1,100 x 62027
ARXB07LALH
ARXB09LALH
ARXB12LALH
ARXB18LALH
ARXB14LALH
CoolingHeating
HighMedLow
HighMedLow
Liquid (Flare)Gas (Flare)
Drain
2.83.255
440370340
0 to 5025312927
4.55.090
800750700
0 to 5025333230
217 x 953 x 59525
3.64.063
590500450
0 to 5025302825
ø25 (I.D.) ; ø32 (O.D.)
kW
W
m3/ h
Pa
dB(A)
mm
mm
kg
Power source
Capacity
Input power
Airflow rate
Static pressure rangeStandard static pressure
Sound pressure level
Dimensions (H x W x D)Weight
Connectionpipe diameter
CoolingHeating
HighMedLow
HighMedLow
Liquid (Flare)Gas (Flare)
Drain
kW
W
m3/ h
Pa
dB(A)
mm
mm
kg
Power source
Capacity
Input power
Airflow rate
Static pressure rangeStandard static pressure
Sound pressure level
Dimensions (H x W x D)Weight
Connectionpipe diameter
7.18.0145
1,100920810
0 to 8040312725
43
ARXB24LATH
ARXB30LATH
ARXB36LATH
ARXA24LATH
ARXA30LATH
ARXA36LATH
ARXA45LATH
ARXB45LATH
9.010.0198
1,4101,2801,150
0 to 8050343229
12.514.0338
1,9701,7901,6700 to 80
60413836
7.18.0190
1,2801,2101,130
30 to 150100383634
43
9.010.0188
1,2801,2101,130
30 to 150100403836
11.212.5312
1,7201,6701,600
30 to 150100434139
45
12.514.0 312
1,7201,6701,600
30 to 150100434139
11.212.5253
1,7101,6001,470
0 to 8050373533
45ø9.52
ø25 (I.D.) ;ø32 (O.D.)
ø22 (I.D.) ;ø26 (O.D.)
230V~ , 50Hz
1918
270 x 1,135 x 700 270 x 1,135 x 700
ø9.52
ø25 (I.D.) ;ø32 (O.D.)ø15.88 ø15.88ø19.05 ø19.05
230V~ , 50Hz
217 x 663 x 59518
ø12.70ø6.35
CoolingHeating
HighMedLowHighMedLow
Liquid (Flare)Gas (Flare)
Drain
kW
W
m3/ h
dB(A)
mm
mm
mm
kg
kg
Power source
Capacity
Input power
Airflow rate
Sound pressure level
Dimensions (H x W x D)Weight
Connectionpipe diameter
Decoration Panel(option)
Decoration Panel(option)
CoolingHeating
HighMedLow
HighMedLow
LiquidGasDrain
kW
W
m3/ h
Pa
dB(A)
mm
mm
kg
Power source
Capacity
Input power
Airflow rate
Static pressure rangeStandard static pressure
Sound pressure level
Dimensions (H x W x D)Weight
Connectionpipe diameter
11.2 12.5 405
2,6001,9501,450
100 to 200100453832
45
12.514.0427
3,5003,0002,460
100 to 250100494542
400 x 1,050 x 500
ø9.52 (Flare)ø19.05 (Flare)
22.425.0
1,1103,9003,3003,000
50 to 300260514845
82
230V~ , 50Hz18.020.0427
3,5003,0002,460
100 to 250100494542
ø25 (I.D.) ; ø32 (O.D.)
25.028.0
1,2504,3004,0003,500
100 to 300250535149
85
ARXC36LATH
ARXD07LATH ARXD09LATH ARXD12LATH ARXD14LATH ARXD18LATH ARXD24LATH
ARXC45LATH ARXC60LATH* ARXC72LATH* ARXC90LATH*
47ø12.70 (Brazing)ø22.22(Brazing)
450 x 1,550 x 700
2.22.825
540450350343025
AUXB07LALH AUXB09LALH AUXB12LALH AUXB18LALHAUXB14LALH
2.83.225550450350353025
4.55.035
680590390383427
5.66.336710580400413527
7.18.084
1,030830450504430
3.64.129600530390373427
15ø6.35
ø12.70
AUXB24LALH
245 x 570 x 570
ø25 (I.D) ;ø32 (O.D.)UTG-UFYC-W50 x 700 x 700
2.6
17ø9.52ø15.88
230V~ , 50Hz
Model nameDimensions (H x W x D)Weight
CoolingHeating
HighMedLowHighMedLow
Liquid (Flare)Gas (Flare)
Drain
kW
W
m3/ h
dB(A)
mm
mm
mm
kg
kg
Power source
Capacity
Input power
Airflow rate
Sound pressure level
Dimensions (H x W x D)Weight
Connectionpipe diameter
230V~ , 50Hz
Model nameDimensions (H x W x D)Weight
5.66.339
1,150940870363029
7.18.046
1,2801,040870383329
9.010.059
1,6001,3001,100
403833
11.212.580
1,8001,3001,100
443833
12.514.099
1,9001,3701,100
463933
14.016.0119
2,0001,3701,100
473933
AUXD18LALH AUXD24LALH AUXA30LALH AUXA45LALHAUXA36LALH AUXA54LALH
246 x 840 x 84023
ø15.88
288 x 840 x 84027
ø19.05ø9.52
ø25 (I.D.) ; ø32 (O.D.)UTG-UGYA-W50 x 950 x 950
5.5
5.66.396
890810730
0 to 5025363430
ø9.52ø15.88
ø9.52ø15.88
ø6.35ø12.70
198 x 700 x 620
133132
&
Indoor units specifications
Floor / Ceiling Compact Wall Mounted
Ceiling
Model name
Note : Specifications are based on the following conditions.Cooling : Indoor temperature of 27˚CDB / 19˚CWB, and outdoor temperature of 35˚CDB / 24˚CWB.Heating : Indoor temperature of 20˚CDB / (15˚CWB), and outdoor temperature of 7˚CDB / 6˚CWB.Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m.Voltage : 230 [V].
Model name
Note : Specifications are based on the following conditions.Cooling : Indoor temperature of 27˚CDB / 19˚CWB, and outdoor temperature of 35˚CDB / 24˚CWB.Heating : Indoor temperature of 20˚CDB / (15˚CWB), and outdoor temperature of 7˚CDB / 6˚CWB.Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m.Voltage : 230 [V].
Model name
Note : Specifications are based on the following conditions.Cooling : Indoor temperature of 27˚CDB / 19˚CWB, and outdoor temperature of 35˚CDB / 24˚CWB.Heating : Indoor temperature of 20˚CDB / (15˚CWB), and outdoor temperature of 7˚CDB / 6˚CWB.Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m.Voltage : 230 [V].
ABYA12LBTH ABYA14LBTH ABYA18LBTH ABYA24LBTH
Model name
Note : Specifications are based on the following conditions.Cooling : Indoor temperature of 27˚CDB / 19˚CWB, and outdoor temperature of 35˚CDB / 24˚CWB.Heating : Indoor temperature of 20˚CDB / (15˚CWB), and outdoor temperature of 7˚CDB / 6˚CWB.Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m.Voltage : 230 [V].
ABYA30LBTH ABYA36LBTH ABYA45LBTH ABYA54LBTH
230V~ , 50Hz
ASYA18LACH ASYA24LACH ASYA30LACH
Wall Mounted
2.22.816
490450370353327
2.83.216
500450370363327
CoolingHeating
HighMedLowHighMedLow
Liquid (Flare)Gas (Flare)
Drain
kW
W
m3/ h
dB(A)
mm
mm
kg
Power source
Capacity
Input power
Airflow rate
Sound pressure level
Dimensions (H x W x D)Weight
EV Kit (option)
Connectionpipe diameter
CoolingHeating
HighMedLowHighMedLowNetNet
Liquid (Flare)Gas (Flare)
Drain
kW
W
m3/ h
dB(A)
mm
mm
kg
Power source
Capacity
Input power
Airflow rate
Sound pressure level
Dimensions (H x W x D)Weight
Connectionpipe diameter
CoolingHeating
HighMedLowHighMedLow
Liquid (Flare)Gas (Flare)
Drain
kW
W
m3/ h
dB(A)
mm
mm
kg
Power source
Capacity
Input power
Airflow rate
Sound pressure level
Dimensions (H x W x D)Weight
Connectionpipe diameter
3.64.030660570490363228
25 27
4.55.042780640550403634
5.66.374
1,000720580463935
7.18.099
1,000820680474237
230V~ , 50Hz
199 x 990 x 655
ø25 (I.D.) ; ø32 (O.D.)
ø6.35ø12.70
ø9.52ø15.88
CoolingHeating
HighMedLowHighMedLow
Liquid (Flare)Gas (Flare)
Drain
kW
W
m3/ h
dB(A)
mm
mm
kg
Power source
Capacity
Input power
Airflow rate
Sound pressure level
Dimensions (H x W x D)Weight
Connectionpipe diameter
9.010.066
1,6301,3701,140
423833
47ø9.52
ø15.88
11.212.585
1,6901,4001,170
453834
12.514.0131
2,0101,6001,230
484235
48ø9.52
ø19.05
14.016.0180
2,2701,7801,280
514536
230V~ , 50Hz
240 x 1,660 x 700
ø25 (I.D.) ; ø32 (O.D.)
4.55.030
670490420443732
2.22.815
490450370343226
2.83.216
500450370353226
3.64.120
560480420383430
4.55.028
680490420433530
3.64.119
560480420393531
ASYA07LACH ASYA09LACH ASYA12LACH ASYA14LACH ASYE07LACH ASYE09LACH ASYE12LACH ASYE14LACH
230V~ , 50Hz 230V~ , 50Hz
275 x 790 x 2159
ø6.35ø12.70
ø13.8(I.D.) ; ø15.8-ø16.7(O.D.)-
275 x 790 x 2159
ø6.35ø12.70
ø13.8(I.D.) ; ø15.8-ø16.7(O.D.)UTR-EV09XB UTR-EV14XB
5.66.335
840770690413935
7.18.064
1,100910730484335
320 x 998 x 22815
ø9.52ø15.88
ø12 (I.D.) ; ø16 (O.D.)
8.09.091
1,240980770524535
135134
Type VRF
Wired Remote Controller
Individualcontrolsystem
Simple Remote Controller
Simple Remote Controller(Without operation mode)
Wireless Remote Controller
IR Receiver Unit
IR Receiver Kit
Group Remote Controller
Centralizedcontrolsystem
Adaptor & Convertor
Service &Maintenance
Central Remote Controller
Central Remote Controller
Touch panel Controller
System Controller
Network Convertor
Network Convertor for LONWORKS®
BACnet® Gateway
Service Tool
Signal Amplifier
Web Monitoring Tool
SU MO TU WE TH FR SA
7
3 126 9 15 18 21
External Switch Controller
Max. controllable remote controller groups
Max. controllable indoor units
Max. controllable groups
On / Off
Operating mode setting
Fan speed setting
Room temp. setting
Room temp. set point limitation
Test operation
Up/down air direction flap setting
Right/left air direction flap setting
Group setting
RC prohibition
Anti freeze setting
Economy mode setting
Failure
Defrosting
Current time
Day of week
R.C. prohibition
Cooling/heating priority
Address display
Schedule timer
On/off timer
Sleep timer
Program timer
Day off
Min. unit of timer setting(Minutes)
Status monitoring system
Electricity charge calculation
Error history
Emergency stop
Control via internet
E-mail notification for malfunction
Type
Model name
*1 "Operation mode" setting is not available for this model.*2 This function is available only through external input. control.
Period
On/off per day
On/off per week
Individual control Centralized control
Air
cond
ition
ing
cont
rol f
unct
ion
Dis
play
Tim
erC
ontr
ol
1
16
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
SimpleRemote
Controller
*1
UTB-YRAUTY-RHKY
UTB-YPBUTY-RSKY
1
16
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
SimpleRemote
Controller
WiredRemote
Controller
UTB-YUBUTY-RNKY
1
16
-
-
-
-
-
Week
4
28
-
-
30
-
-
-
-
-
SU MO TU WE TH FR SA
7
3 126 9 15 18 21
8
96
-
-
-
-
-
-
-
-
-
-
-
Week
4
28
-
-
-
-
10
-
-
-
-
-
100
100
16
-
-
-
-
-
-
-
-
-
-
-
Week
20
140
-
-
-
-
10
-
-
-
-
-
-
400
400
64
-
Week
4
28
-
-
10
-
-
-
-
-
GroupRemote
Controller
UTB-YDBUTY-CGGY
1
16
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
5
-
-
-
-
-
-
WirelessRemote
Controller
UTB-YVBUTY-LNHY
*2*2
TouchPanel
Controller
UTY-DTGY
400
400
400
Year
20
140
-
-
-
10
-
-
-
SystemController(Software)
UTY-APGX
1600
1600
1600
-
Year
72
504
-
-
-
10
-
UTY-RSKY
UTY-LNHY
UTY-LRHYB1
-
UTY-DTGY
UTY-CGGY
UTY-DCGY
UTY-VGGXZ1
UTY-VLGX
UTY-ABGX
UTY-ASGX
UTY-RNKY
J-II & V-II
UTY-VSGX
UTY-AMGX
UTY-TEKX
UTY-APGXUTY-PEGX
UTY-RHKY
UTB-YWC
UTB-YPB
UTB-YVB
-
UTB-YCA
-
UTB-YDB
UTR-YRDA
UTR-YLLA
UTY-ABGX
UTY-ASGX
UTB-YUB
UTY-VSGX
UTY-AMGX
UTR-YESAUTY-TEKX
UTY-APGX
UTB-YRA
S
UTB-YWA
-
CentralRemote
Controller
UTY-DCGY
CentralRemote
Controller
UTB-YCA
Control Systems Lineup Comparison table of Controllers
137136
System diagram
SystemAir ConditioningCentral Control
Air ConditioningIndividual Control
Outdoor unit
Indoor unit
Signal AmplifierUTY-VSGX
General-purpose Building Control Computer
BuildingManagement
Service Tool (Software)UTY-ASGX
USBAdaptor
(Field supplied)
USBAdaptor
(Field supplied)
*2*2
NetworkConvertor
UTR-YRDA
Card-key
(Field supplied)
For single splitNetworkConvertorUTR-YRDA
Connectable tovarious sized BMS/BAS
Web Monitoring VRF System Side(Software)UTY-AMGX
Internet orPublic Telephone Line
(Monitoring side)
*1. BMS/BAS: Building Management System/Building Automation System*2. USB Adaptor is U10 USB Network interface of Echelon® corporation.
or
IR Receiver UnitUTB-YWA
Wired Remote ControllerUTB-YUB
External Switch ControllerUTR-YESAUTY-TEKX
Network Convertor for LONWORKS®UTR-YLLA
System Controller (Software)UTY-APGX
Wireless Remote ControllerUTB-YVB
Simple Remote ControllerUTB-YPB
Simple Remote ControllerUTB-YRA Without operation mode
It supports every user's needs by offering a variety of control systems available, such as individual control, central control and building management system control options
Wiring system•Wiring construction of the control system is made of power source wiring, transmission wiring and remote controller wiring.•Total wiring length (total length of transmission line) can be extended up to 2000m (by using signal amplifiers).
USBAdaptor
(Field supplied)
*2
USBAdaptor
(Field supplied)
*2
*1
BACnet ® GatewayUTY-ABGX
Group Remote ControllerUTB-YDB
Central Remote ControllerUTB-YCA
Transmission line (VRF Network)Remote controller lineUSB cable
LONWORKS® NetworkEthernetSignal line(Single split system)Group Remote Controller line
Transmission line
Remote Controller line
Group Remote Controller line
Signal line (single system)
USB cable
Ethernet
LONWORKS® Network
USBAdaptor
USB Adaptor
USB Adaptor (Field supplied)
Network Convertor
Network Convertor Network Convertor
Signal Amplifier
Web Monitoring Tool Trouble free operation at all times by remote monitoring system.
Service ToolExtensive monitoring and analysis functions for installation and maintenance.
2 Remote Controllers Indoor unit can be controlled from both remote controllers.
External Switch ControllerIndoor units can be controlled by combining with Card-key switch such as hotel room.
System without remote controllerTogether with Touch Panel Controller, it is possible to build non remote controller system.
IR Receiver UnitDuct type indoor unit can be controlled with Wireless Remote Controller.
Remote controller lineMaximum 16 units can be controlled
Group Remote ControllerMaximum 8 remote controller groups can be controlled
Central Remote ControllerMaximum 16 units can be connected.One central remote controller can control up to 64 groups / 400 indoor units.
System Controller•Maximum 1600 indoor units can be controlled. •Air conditioning control •Operation monitoring •Status monitoring system•Electricity charge calculation
Service Tool
Big multi system
Card key
Single system
Outdoorunit
Indoor unit(Cassette)
Indoor unit(Duct)
SystemController
Central remoteController
GroupRemote Controller
SimpleRemote Controller
SimpleRemote Controller
WirelessRemote Controller
WiredRemote Controller
External SwitchController
IR Receiverunit
BACnet® GatewayBACnet®
LONWORKS®
BACnet®
BACnet® Operator Workstation (B-OWS)
Combination ofindividual remote controller
Wired, Simple and Wireless Remote Controllers can be used jointly.
Internetor
Public Telephone Line
Transmission lineline is non-polar 2-conductor.
LONWORKS®Network
Building Management System
2,000m
Max. transmissionline length
(Monitoring side)
(Monitoring side)
(Monitoring side)
Web Monitoring Tool
(VRF system side)
USB Adaptor
Signal Amplifier
NetworkConvertor
Control Systems for series
139138
System diagram
SystemAir ConditioningCentral Control
Air ConditioningIndividual Control
Outdoor unit
Indoor unit
Signal AmplifierUTY-VSGX
General-purpose Building Control Computer
BuildingManagement
Service Tool (Software)UTY-ASGX
USBAdaptor
NetworkConvertor
UTY-VGGXZ1
Card-key
(Field supplied)
(Field supplied)
For single split
Connectable tovarious sized BMS/BAS
NetworkConvertorUTY-VGGX
Web Monitoring Tool (Software)UTY-AMGX
(VRF system side)
Internet orPublic Telephone Line
(Monitoring side)
or
IR Receiver UnitUTB-YWBUTB-YWC
Remote/Monitoring side
Internet or PublicTelephone Line
IR Receiver KitUTY-LRHYB1
Wired Remote ControllerUTY-RNKY
External Switch ControllerUTY-TEKX
Network Convertor(BMS / LONWORKS®)UTY-VLGX
System Controller (Software)UTY-APGX
Simple Remote ControllerUTY-RSKY
Simple Remote ControllerUTY-RHKYWithout operation mode
Wireless Remote ControllerUTY-LNHY
The V-II system supports every users needs by offering a variety of Control systems,including individual control, central control and building management control options.
Wiring system•Wiring construction of the control system is made of power source wiring, transmission wiring and remote controller wiring.•Total wiring length (total length of transmission line) can be extended up to 3,600m (by using signal amplifiers).
*2USB
Adaptor
(Field supplied)
*2
USBAdaptor
(Field supplied)
*2
*1
USBAdaptor
(Field supplied)
*2
BACnet ® Gateway (Software)UTY-ABGX
Group Remote ControllerUTY-CGGY
Touch Panel ControllerUTY-DTGY
*1. BMS/BAS: Building Management System / Building Automation System*2. USB Adaptor is U10 USB Network Interface of Echelon® Corporation.
Transmission line (VRF Network)Module linkRemote controller lineUSB cable
LONWORKS® NetworkEthernetSignal line(Single split system)Group Remote Controller lineThe devices above cannot be connected to the S series.
(Except System Controller & BACnet® Gateway)
Refrigerant system 1 Refrigerant system 2
USB adaptor
USB adaptor
USBadaptor
USB adaptor
Network Convertor
NetworkConvertor
Network Convertor Network ConvertorSignal AmplifierWeb Monitoring Tool Trouble free operation at all times by remote monitoring system.
Transmission lineline is non-polar 2-conductor.
Service ToolExtensive monitoring and analysis functions for installation and maintenance.
2 Remote Controllers Indoor unit can be controlled from both remote controllers.
External Switch ControllerIndoor units can be controlled by combining with Card-key switch such as hotel room.
System without remote controllerTogether with Touch Panel Controller, it is possible to build non remote controller system.
Remote controller lineMaximum 16 units can be controlled
Group Remote ControllerMaximum 8 remote controller groups can be controlled
Touch Panel ControllerOne Touch Panel Controller can control up to 400 groups / 400 indoor units.
System Controller UTY-APGX•Maximum 1,600 indoor units can be controlled. •Air conditioning control •Operation monitoring •Status monitoring system•Electricity charge calculation
IR Receiver KitCassette type indoor unit can be controlled with Wireless Remote Controller
IR Receiver UnitDuct type indoor unit can be controlled with Wireless Remote Controller.
Service Tool
Big multi system
Card key
Single system
Outdoorunit
Indoor unit(Cassette)
Indoor unit(Duct)
SystemController
Touch PanelController
GroupRemote Controller
SimpleRemote Controller
SimpleRemote Controller
Transmission line
Module link
Remote Controller line
Group Remote Controller line
Signal line (single system)
USB cable
Ethernet
LONWORKS® NetworkWireless
Remote Controller
WirelessRemote Controller
External SwitchController
IR Receiverunit
(Remote / Monitoring side)
BACnet® GatewayBACnet®
LONWORKS®
BACnet®
BACnet® Operator Workstation (B-OWS)
NW1
NW2NW3NW4
Combination ofindividual remote controller
Wired, Simple and Wireless Remote Controllers can be used jointly.
Internetor
Public Telephone Line
Internetor
Public Telephone Line
LONWORKS®Network
Building Management System
3,600m
Max. transmissionline length
(Monitoring side)
(Monitoring side)
(Monitoring side)
Web Monitoring Tool
(VRF system side)
Central Remote ControllerUTY-DCGY
CentralRemote Controller
Central Remote ControllerMaximum 100 indoor units can be controlled.
Control Systems for & series
141140
The room temperature can be controlled by detecting the temperature accurately from the built-in sensor
UTB-YUB/UTY-RNKY
•Simple operation with Built-in Weekly / Daily Timer.•Control up to 16 indoor units.•Up to 2 wired remote controllers can be connected to a single indoor unit.
•A large On / Off button is provided in the centre of the remote controller for easy operation.
•Background light enables easy operation in a darkened room.
•Following an error display, diagnostics can be carried out on the controller.
User-friendly operation
Built-in timers
Wired Remote Controller
Compact remote controller provides access to basic functions
UTB-YPB/UTY-RSKYUTB-YRA/UTY-RHKY (Without operation mode)
•Up to 16 indoor units can be controlled with one remote controller.•Suitable for hotels or offices as it is easily operated with no complex functions.
Simple Remote Controller
Weekly timer: Possible to set ON/OFF time to operate twice each day of the week.Setback timer: Possible to set temperature for two times spans and for each day of the week.At "Weekly timer" + "Set back timer" setup
Indoor temperature can be detected accurately by the inclusion of a thermo sensor in the body of the wired controller. This new wired remote controller and the optional remote sensor allows flexibility in sensor location, suitable for all requirements.
Accurate and comfortable Built-in timersSelect from 4 different timer programs: On / Off / Program / Sleep Program timer: The program timer operates the ON and OFF timer once within a 24 hour period.Sleep timer: The sleep timer function automatically corrects the set temperature according to the time setting to prevent excessive cooling or heating during sleep hours.
System addressingDuring installation work, system addressing can be performed using the Wireless Remote Controller, thus eliminating manual switch setting.
Easy installation and operation•Code selector switch prevents indoor unit mix-up. (Up to 4 codes can be set.)
•Wide and precise transmitting range.
Example of changing sensorRemote Sensor in the bedroom
Wired Remote Controller in the living room
Wired remotecontroller
Indoor unit
Remotesensor
The detecting point can be easily changed
Day Night
Displayed temperature is set temperature.
Specifications Specifications
UTB-YPB/UTY-RSKY UTB-YRA/UTY-RHKYWithout operation mode
UTB-YVB/UTY-LNHY
•A single controller controls up to 16 indoor units.
Wireless Remote Controller Max. controllable
16indoor units
Max. controllable
16indoor units
Max. controllable
16indoor units
Selectable
4daily timers
Functions
*1: "Operation mode" setting is not available. It is recommend to use together with other type controller.
Two methods are available for determining the cause of failure in the event of a malfunction occurs:
Diagnosis check function
Simple installationComponents are compatible with standard switch boxes. Flat back surface allows to be installed wherever it is needed.
WirelessRemote Controller
Indoor unit
Transmission line
Outdoor unit
Simple and sophisticated operations with a choice of 4 daily timers
UTB-YWA/UTB-YWC
IR Receiver Unit
Necessary to control for all duct type by Wireless Remote Controller IR Receiver Unit
Duct type indoor unit
IR Receiver Kit
Cassette type indoor unit can be controlledwith Wireless Remote Controller
WirelessRemote Controller
WirelessRemote Controller
IR Receiver Kit
DC12V is supplied by the indoor unit.
Model name
Power Source
Dimensions (H x W x D) (mm)
Weight (g)
DC 12V
120 x 75 x 14
90 (100 : UTY-RSKYT)
UTB-YPB/UTY-RSKY
DC 12V
120 x 120 x 17
160
UTB-YUB/UTY-RNKY
DC 12V
120 x 75 x 14
90 (100 : UTY-RHKYT)
UTB-YRA/UTY-RHKY
Model
On / Off
Fan control
Operation mode
Room temp. setting
UTB-YPB/UTY-RSKY UTB-YRA/UTY-RHKY
*1
Model name
Battery
Dimensions (H x W x D) (mm)
Weight (g)
DC 12V
122 x 60 x 26.5
150
UTB-YWA/UTB-YWC
1.5V (R03 / LR03 / AAA) x 2
158 x 56 x 20
70
UTB-YVB/UTY-LNHY
DC 12V
213.8 x 213.8x 25.7
140
UTY-LRHYB1
UTY-LRHYB1
UTY-LNHYUTB-YVB
Controller
143142
Group control of indoor units with simple operation
UTB-YDB / UTY-CGGY
•Up to 8 remote controller groups can be controlled by one Group Remote Controller.
•Up to 64 Group Remote Controllers can be connected in one VRF network system.
•Network Convertor is required to connect Group Remote Controllers to a VRF network system.
(Network Convertor allows up to 4 Group Remote Controllers)
Group Remote Controller
Specifications
DC12V is supplied by a network converter.
Model name
Power Source
Dimensions (H x W x D) (mm)
Weight (g)
DC 12V
120 x 120 x 17
200
UTB-YDB / UTY-CGGY
Max. controllable
64group R.C. in a VRF
network system
Max. controllable
8remote
controller groups
Specifications
UTY-DCGY
Central Remote Controller
Central control of small- and medium-sized buildings and tenants.
Model name
Power Source
Dimensions (H x W x D) (mm)
Weight (g)
Control Panel
DC 5 V
120 x 162 x 26
308
UTY-DCGY
Max. controllable
16groups
Max. controllable
100Indoor units
•Diverse control of indoor units •Weekly timer •Automatic clock adjustment •Error history
Functions
Refrigerantsystem 2
Refrigerantsystem 1
ON / OFF, Operating mode, Room temperature and Fan speed setting can be controlled / monitored centrally or individually.
High performance and compact sizeThe weekly timer is provided as a standard function.1. The timer can be set up for up to 4 times per day. (On / Off,
operating mode, set temperature)2. Allows separate settings for each day of the week.
Built-in weekly timers
Centralcontrol
ON/OFFcontrol
Weeklytimer
•Single Group Remote Controller controls and monitors up to 8 remote controller groups.
Control up to 8 remote controller groups
Hotel
Restaurant
Lobby
21
LoungeOffice room
Guest room
Group RemoteController
NetworkConvertor
Restaurant
Lobby
Office & Lounge
Group Remote Controller 1: To control office room, lounge, restaurant and lobby (8 remote controller groups)
Group Remote Controller 2: To control guest room and launge (7 remote controller groups)
• Individual control and monitor of 100 indoor units • 5 inch TFT color screen • User friendly view and easy operation • External input / output contact • Detachable power supply unit• Corresponds to 7 different languages like English, Chinese, French, German, Spanish, Russian, Polish.
• It allows multiple indoor units grouping (Max.16 groups controlled)• Interlock with external device
System overview
• The control panel and power supply unit can be installed separately.
• For flexibility in installation, the Control panel can be built into the wall or fix on the wall.
Easy Installation
Group : Division A Group : Division B
Group : Hallway
Group : Division C
Group : 3F
Emergency stop function
Group : Tenant A Group : Tenant B Group : Tenant C
Group : 2F
Control panel + Power supply unit
Control panel
CeilingPower supply unit
SW BOX
Setting pattern 1 Setting pattern 2
Wall
Wall
PACKING LIST
Power Supply Unit
100-240V, 50-60Hz, Single phase
99 x 135 x 40
355
Packing List Control Panel / Power Supply Unit / Connecting cable, etc.
Controller
145144
Emergency stop function
UTY-DTGY•Large-sized 7.5-inch TFT color•LCD Easy finger touch operation•Stylish shape and design to suit all application•No additional component is required for installation•Up to 400 indoor units can be controlled•Selectable 2 display types (Icon / List) in monitoring mode•Corresponds to 7 different languages, English, Chinese, French, German, Spanish, Russian, Polish.
Touch Panel Controller
•Emergency stop function: Air conditioner can be turned off through the external input control
•The stored data can be transferred via USB port•CSV format data edited by PC can be imported to Touch Panel Controller.
Versatility
Automatic clock adjustment
Specifications
Model name
Power Source
Dimensions (H x W x D) (mm)
Weight (g)
Interface
100-240V 50/60Hz
260 x 246 x 54
2,150
USB 2.0
UTY-DTGY
•Wide range of simple-to-understand icons•Operation can be selected using your finger or the dedicated touch pen by pressing the appropriate on-screen icon•Up-to-date status display•Background color identifies current control operation blue for monitoring, green for operational control
Easy operation
Functions
Easy installationSchedule control
Flexible groupingIndividual control
Indoor units operation monitoring
Data transferavailable by USB
CSV format data edited by PC can be imported to Touch Panel Controller.
Max. controllable
400indoor units
•Touch Panel Controller is easily mounted to the wall.•Flat back surface allows to be installed wherever it is needed.
•No additional component is required for installation.
The time setting of each controller can be set in batch automatically.
Control up to 400 indoor units•The central remote controller performs system control after you select All Groups, User Defined Groups, or Individual Remote Controller Groups.
•Accurate control of functions such as Start / Stop, Operating Mode, Temperature, and Air Velocity ensures occupancy comfort.
Central controlAny of 6 functions of the individual remote controller can be locked from the Central Remote Controller: all functions, timer mode, operating mode, temperature setting, filter reset, on/off.All functions can be controlled via the Central Remote Controller only.
Functions•Built-in weekly timer•Memory functions•Error display
Easy Installation•The controller can be installed on any flat surface.•The control panel and transmission adaptor can be installed separately.
•For flexibility in installation, the main unit can be built into the wall or exposed.
Specifications
UTB-YCA
•Up to 400 indoor units / 400 remote controller groups / 64 groups can be controlled by one system.
•Up to 16 central remote controllers can be connected into one system allowing operation and monitoring to be achieved from the central control room, at each floor, by each tenant, or in the plant room.
Central Remote Controller
Functionality in a compact housing with built-in weekly timer
Model name
Power Source
Power Consumption (W)
Fuse Capacity (A)
Dimensions (H x W x D)(mm)
Weight (g)
Control Panel
DC 12V
143 x 296 x 22
550
Transmission Adaptor
220-240V 50-60Hz Single phase
107 x 288 x 100
1,300
4.8
3
UTB-YCA
Individual
Individual Remote Controller Groups
Individual Individual
Individual Individual Individual
All
All Groups
Group
User Defined Groups
Group
Group
GroupGroup
Controllable method
Connecting cable
Power Supply 220-240V
Transmission line
Transmission Adaptor
Control Panel
PACKING LISTPacking List Control Panel / Transmission Adaptor / Connecting Cable
Max. controllable
400remote
controller groups
Max. controllable
400indoor units
Max. controllable
64groups
Controller
147146
User friendly view and operation
Specifications
UTY-APGX
System Controller
System Controller realizes the advanced integrated monitoring & control of VRF network system from small scale buildings to large scale buildings.
Personal Computer
Operating System
CPU
HDD
Memory
Interface
Other Software Required
AT compatible machine that runs Microsoft® Windows®
•Batched stop •Divers control of indoor units •Oprating & control record•Schedule control •Error display & E-mail nitification •Prohibition setting
Others
Functions
PACKING LIST
Wibe Key Software protection key to be inserted in a USB slot running System Controller. System Controller may only run on a PC with Wibu Key. Remote VRF Explorer software does not require Wibu Key.
CD-ROM Includes the software for System Controller. Both VRF Controller and VRF Explorer software is included. Monitor mode (Site)
Monitor mode (Building)
Monitor mode (Floor) Monitor mode (List) Schedule setting
Main operation monitoring screen Management functions Operation monitoring of each siteMonitoring located site
Microsoft® Windows® XP Professional (Service Pack 3 or later / English version),Microsoft® Windows Vista® Home Premium, Business (Service Pack 2 or later / Corresponds to 7 different languages.*), Microsoft® Windows® 7 Professional (64-bit is not supported. / Corresponds to 7 different languages.*) *English, Chinese, French, German, Spanish, Russian, Polish
USB port is required for each of the followings for Server PC ;• Wibu Key (Software protection key) • Echelon® U10 USB Network Interface (Required for each VRF Network) Ethernet port is required for remote connection using internet.
Intel® Pentium® / Celeron 2 GHz (VRF Controller), 1 GHz (VRF Explorer) or higher
40 GB or more of free space (5 GB for VRF Explorer PC)
2 GB or more (VRF Controller), 1 GB or more (VRF Explorer)
Adobe® Reader® 9.0 or later
Accelerator Requires the internal graphics accelerator be compatible with Microsoft® DirectX® 9.0
Max. controllable
1,600indoor units
Max. controllable
400outdoor units
Max. controllable
4VRF network systems
Model name UTY-APGX
Software
Personal computer must be field supplied. U10 USB Network Interface must be field supplied. Contact Echelon® Corporation or its local sales representative for detail.Product Name : U10 USB Network Interface - TP/FT-10 Channel Model Number: 75010R
• Up to a maximum of 4 VRF network systems, 1600 indoor units, and 400 outdoor units can be controlled.
• Supports VRF S series, V series and V-ll series. • In addition to air conditioning precision control function, central remote control, electricity charge calculation, schedule management, and energy saving functions are strengthened and building manager and owner needs are met.
• Corresponds to 7 different languages (English, Chinese,French, German, Spanish, Russian, Polish)
On site central control
Remote central controlSystem Controller may be used on site or remotely over var ious networks for remote central control. System Controller requires 2 softwares working together. VRF Controller runs on site and communicate with VRF system. VRF Explorer runs remotely and provides user interface and communicate with the VRF Controller. VRF Controller and VRF Explorer program may run in a s ingle PC or in d i f ferent PCs separated by network. By using VRF Explorer software, one PC can perform central control of 10 VRF system sites with max. 20 buildings per site.
Remote centralized control
Max. 4 VRF network systems per site
Building Management Company A (In charge of the day shift)
Internetor
Telephone Lineor
LAN
Internetor
Telephone Lineor
LAN
Building management company,management center, etc.
BuildingManagement Company B
(In charge of the night shift)
Security Company
Headquarters Management Center
A maximum of 10 locations, such as offices or factories
1 VRF Explorer can control or monitor up to 10 sites.
1 VRF Controller can be monitored from any number of VRF Explorers (Up to 5 connections simultaneously).
Office Management Center
VRF Explorer
VRF Explorer
VRF Explorer
VRF ExplorerVRF Explorer
VRF Explorer
VRF Controller
VRF Controller
Internetor
Telephone Lineor
LANVRF Explorer
VRF Controller
Central Monitoring Screenfor all Properties
Special Property Detailed Monitoring Screen
Energy saving management UTY-PEGX:software
Pow
er c
onsu
mpt
ion
Time
Outdoor unit capacityupper limit
Peak cut operationControls overall operation while maintaining comfort according to the overall power consumption target value.
Apportions the power used by indoor and outdoor units and automatically calculates the electricity charge for each tenant.When you want to calculate the power used during a certain period in hotels, etc., computation linked with an electric meter is also possible. (Option)
Outdoor unit capacity saveSets an upper limit of outdoor unit capacity and performs capacity save operation at peak times.
Indoor unit rotation operationReduces annual power consumption by operating indoor units in rotation.
Forced thermostat off range
Target power consumption
Outdoor unit stop range
Outdoor unit capacity control screen
Ideal control line (Use of average power consumption)
Shows change in power consumption by time
Indoor unit rotation screen
Electricity charge apportionment Option
Option
Billing management for users for a set period of time, such as for hotels
Signal transmission line
1Ø, 2wire 230V, 50Hz
DPM
System Controller
Outdoor unit
Room 301 Room 302 Room 303
Room 201 Room 202 Room 203
Room 101 Room 102 Room 103
PowPowePowerrdistribuibubutiotionn
boardd
PowPoweP rdistribuibubutiotion
boardd
CT
3Ø, 4
wire
400
V, 5
0Hz
Controller
149148 Personal computer must be field supplied. U10 USB Network Interface must be field supplied. Contact Echelon® Corporation or its local sales representative for detail.Product Name : U10 USB Network Interface - TP/FT-10 Channel Model Number : 75010R
•Split type systems can be controlled from a central remote controller or PC controller through connection to the VRF's network convertor. •Standard remote controller and central remote controller provide On / Off control, master control, temperature and fan control, etc.•A single network convertor can be used to connect and control up to 16 single units.
Installation example Installation example
Specifications Specifications
UTR-YLLA / UTY-VLGX•For connection between VRF network system and a LONWORKS® open network for management of small to medium-sized BMS and VRF network system.
•The UTY-VLGX permits central monitoring and control of a VRF network system from a BMS through a LONWORKS® interface.
•Up to 128 Indoor units can be connected to one Network Convertor for LONWORKS®
Network Convertor for LONWORKS®
Transmission specifications (BMS side)
Model name
Power Source
Power Consumption (W)
Dimensions (H X W X D) (mm)
Weight (g)
50-60Hz 220-240V
8.5
67 x 288 x 211
1,500
UTR-YRDA / UTY-VGGXZ1 Model name
Power Source
Power Consumption (W)
Dimensions (H X W X D) (mm)
Weight (g)
220-240V 50/60Hz
4.5
67 x 288 x 211
1,500
UTR-YLLA / UTY-VLGX
Personal Computer
Memory
Interface
Other Software Required
Operating System
CPU
AT compatible machine that runs Microsoft® Windows®
Packing List CD-ROM / Wibu Key
Microsoft® Windows® XP Professional (Service Pack 3 or later / Corresponds to 7 different languages.*)Microsoft® Windows Vista® Home Premium, Business (Service Pack 2 or later / Corresponds to 7 different languages.*)Microsoft® Windows® 7 Home Premium, Professional (Corresponds to 7 different languages.*)*English, Chinese, French, German, Spanish, Russian, Polish
USB port (x 2-5) is requiredEthernet port is required
Intel® Pentium® / Celeron®, AMD Athlon / Duron processor 2 GHz or higher
2 GB or more
40 GB or more of free spaceHDD
Adobe® Reader® 9.0 or later
UTR-YRDA / UTY-VGGXZ1 •This network convertor is to be used for connecting single split system or group remote controller with the VRF network system.
•Please select the function by switching the dip switch during the installation.
Network Convertor
UTY-ABGX•The VRF network system can be incorporated into a Building Management System.•Enables central control of up to 1,600 indoor units through BACnet®, a global standard for open networks. •Conforms to ANSI / ASHRAE Standards® 135-2004 BACnet® Application Specific Controller (B-ASC) BACnet® / IP over Ethernet.
•Connects up to 4 VRF network systems (1,600 indoor units / 400 outdoor units) per gateway.•Supports VRF S/V series and V-II series
BACnet® Gateway
* 2 refrigerant circuits can be covered by a single network convertor. Up to a total of 16 network convertors and central remote controller adapters can be connected in a single VRF network system.
78kbps
FT-X1 (Echelon® Corporation)
Free topology
None(It attaches at the terminal of a network.)
Transmission speed
Transceiver
Transmission way form
Terminal resistor
Software
CD-ROM(Software)
SoftwareProtection Key
Installation example
Lighting facilities
Security system
Automatic fire alarm interface
Ventilation system
BACnet Operator Workstation (B-OWS)
USB adaptor (Field supplied)
USB adaptor (Field supplied)
USB adaptor (Field supplied)
USB adaptor (Field supplied)CD-ROM
(Software)Software
Protection Key
(UTY-ABGX)BACnet Gateway
Outdoor unitIndoor unit
VRF network system 1
VRF network system 2
Indoor unit
BACnet
Max. 4 VRF network systems *1: USB adaptor is U10 USB Network
Interface of Echelon® Corporation.
®
®
®
= BACnet® Gateway for each system.= USB cable= Transmission line (VRF Network)= Ethernet
*1
Outdoor unit
Max. controllable
128indoor units
Max. controllable
4Units to BMS
Max. controllable
4VRF network systems
Max. controllable
400outdoor units
Max. controllable
1,600indoor units
Max. controllable
16Network
Convertor units
Model name UTY-ABGX
PACKING LIST
(UTR-YRDA) (UTR-YLLA)
Used for connecting Group Remote Controller
Big Multi
VRF networksystem
System Controller Single Split
Group of Single Split
4 group remort controllers can be connected to a single Network convertor.
VRF networksystem
Network Convertor
Group Remote Controller
Please consult your distributor for connectable split type air conditioner. Up to 100 network convertors may be connected in a single VRF network system. A single network convertor is considered as a single refrigerant system, irrespective of the number of connected single models.
Network Convertor
USBadaptor
General-purpose building control computer(LONWORKS® device)
LONWORKS® Network
NetworkConvertor
VRF network system 1 Lighting facilities
Security system
Automatic firealarm interface
Ventilation system
Max. 128 indoor unitsMax. 100outdoor units
Max. 4 NetworkConvertor
VRF network system 2
Max. 128 indoor unitsMax. 100outdoor units
The BACnet Gateway version 2.0 is eligible to display BTL Mark. Founded by BACnet International, BTL (BACnet Testing Laboratories) is an indication of worth trusting for its quality after passing the strict tests.
Adaptor & Convertor
151150
UTY-VSGX•Transmission Line length can be extended up to 3,600m for V-II series (2,000m for S series) with multiple Signal Amplifiers.
•Up to 8 signal amplifiers can be installed in a VRF network system.•A signal amplifier is required,(1) When the total wiring length of the transnission line exceeds 500m.(2) When the total number of units on the transnission line exceeds 64.
Signal Amplifier
External Switch Controller
Wiring connection
Specifications Specifications
UTY-ASGX
•Operation status can be checked and analyzed to detect even the smallest abnormalities•Storage of data on system operation status on a PC allows access even from off site.•Up to 400 indoor units (a single VRF network system) can be controlled and monitored for large scale buildings or hotels•This software can be connected to any point of transmission line with USB adaptor (field supplied).•Supports VRF S/V series and V-II series.
Service Tool
Extensive monitoring and analysis functions for installation and maintenance
Personal Computer
Model name
Operating System
CPU
HDD
Memory
Interface
Software
Hardware
AT compatible machine that runs Microsoft® Windows®
Installation example
•Equipment Detail (List)•Error History•Remote File Download•System List•Commissioning Tool
PACKING LISTPacking List CD-ROM / Wibu Key
Installation exampleAuto mode operation, which switches the cooling and the heating automatically, is enabled by using the sensor switch and External Switch Controller. Note: All indoor units will operate in the same mode.
Microsoft® Windows® XP Professional (English version / Service pack 3 or later), Microsoft® Windows® Vista® Home Premium, Business Edition (English version / Service pack 2 or later), Microsoft® Windows® 7 Professional (64-bit is not supported. / English version / Service pack 1 or later)
USB port for U10 USB Network Interface and Software protection key.
Intel® Pentium® / Celeron®, AMD AthlonTM / DuronTM 1 GHz or higher
Internet Explorer 6.0 or 7.0 or 8.0 / Adobe® Reader® 9.0 or later
CD-ROM drive
USB port (for U10 USB Network Interface Max.4, Software protection key)Following interface is required for remote connection:Public Telephone LIne : Modem is requiredInternet using LAN : Ethernet port is required
1 GB or more
10 GB or more of free space 40 GB or more of free space
B
AD
Signal Amplifier
C
Electrical wiring
UTR-YESA / UTY-TEKX
•In combination with a field supply Card-Key Switch or other sensor, the External Switch Controller allows control of the ON / OFF, Room temperature, Fan speed and Master control functions. This makes this product suitable for installations such as hotel rooms.
•Card-key or other sensor switches are available as a field supplied parts.
Air conditioner switching can be controlled by connecting other sensor switches
RemoteController
Line
Indoor Unit 1 2 3 E COM SW1 SW2
Card-key
Externalinput
RemoteController
Line
Indoor Unit 1 2 3 E COM SW1 SW2
Sensor SW
Externalinput
Card-key(Field supplied)
Sensor SW(Field supplied)
External Switch Controller
External Switch Controller
Note 1. Please choose a thermosensor switch which can be set up for T1 and T2.
Note 2. The remote controller's operation is prior to the auto mode operation.
Roo
m te
mp.
Time
T1
T2
Cooling
Heating
Model name
Power Source
Dimensions (H X W X D) (mm)
Weight (g)
DC 12V
120 x 75 x 30
90
UTR-YESA / UTY-TEKXModel name
Power Source
Power Consumption (W)
Dimensions (H X W X D) (mm)
Weight (g)
220-240V 50/60Hz
4.5
67 x 288 x 211
1,500
UTY-VSGX
DC12V is supplied by the indoor unit.
Software
UTY-AMGX
•Troubleshooting is performed by monitoring each air conditioning unit remotely during periodical system checks.•Error notification can be automatically transmitted to several locations using the internet*1.•Requires either a dedicated internet connection or public telephone line.•Determination of an error occurrence can be made through error warnings and equipment status information obtained from a remote location.•The monitoring data in a remote side can be optionally downloaded. And, this data can be displayed in offline mode of the service tool.•Monitoring side computer is not required to install special software, requires only general web browser.•Supports VRF S/V series and V-II series.
Web Monitoring Tool
Product features
Software
(Field supplied)
Refrigerant piping
Tran
smis
sion
line
Indoor unit
Indoor unit
USB adaptor(Field supplied)
Functions•Equipment Detail (Diagram)
Support 4 VRF network systemsUSB adaptor (max. 4 adaptors per PC) permit, monitoring of up to 1,600 indoor units.Suitable for large-scale buildings or hotels.
VRF NetworkSystem 2
VRF NetworkSystem 3
VRF NetworkSystem 4
Indoor unitMax. 400
Indoor unitMax. 400
Indoor unitMax. 400
Indoor unitMax. 400
Web Monitoring System
Indoor unit
Transmission line
USB adapter(Field supplied)
Outdoor unit
WebMonitoring
Tool
USB adaptorsVRF Network System SideMonitoring Side
orInternet
PublicTelephone
Line
UTY-ASGX UTY-AMGX
Personal computer must be field supplied. U10 USB Network Interface must be field supplied. Contact Echelon® Corporation or its local sales representative for detail.Product Name : U10 USB Network Interface - TP/FT-10 Channel Model Number: 75010R
*1: Use of internet mail system required.
1 GB (Vista, 7), 512 MB (XP) or more
Max. Monitorand controll
100outdoor units
Max. Monitorand controll
400indoor units
VRF network systemcan be supported
41,600indoor units
can be supported
SU MO TU WE TH FR SA
7
3 126 9 15 18 21
T1 = ON, T2 = OFF
To individual dry contact
Sensor SW(Field supplied)
External Switch Controller (UTY-TEKX)VRF Network
System 1
Adaptor & Convertor, Service & Maintenance
153152
Optional Parts for VRF
Wired Remote ControllerIndividual control
Without operation mode
Wireless Remote Controller
IR Receiver Kit
IR Receiver Unit For All Duct type
For All Cassette type
Group Remote ControllerCentralized control
Central Remote Controller
Touch panel Controller
System Controller
Network ConvertorAdaptor & Convertor
Network Convertor for LONWORKS®
BACnet® Gateway
Signal Amplifier
External Switch Controller
EV KitRefrigerant Piping Parts For Compact Wall Mounted type
Decoration PanelPanelFor Compact Cassette type
For Cassette type
Service Tool (software)Service
Web Monitoring Tool (software)
Auto Louver Grille Kit
Remote Sensor Others For All Duct type
Drain Pump Unit
Wide Panel
Panel Spacer
Fresh Air Intake Kit
Air Outlet Shutter Plate
For Cassette type
Insulation for High Humidity
For Compact Cassette type
For Cassette type
For Compact Cassette type
For Cassette type
For Cassette type
For Cassette type
For Ceiling type
For Compact Duct / Low Static Pressure Duct / Duct type
For Low Static Pressure Duct / Duct / Ceiling type
For Low Static Pressure Duct / Duct type
For Low Static Pressure Duct / Duct type
For High Static Pressure Duct type
For Compact Cassette type
S
-
-
-
-
-
-
-
-
-
J-II V-II
UTB-YUB
UTB-YPB
UTB-YRA
UTB-YVB
UTB-YDB
UTB-YCA
UTY-APGX
UTR-YRDA
UTR-YLLA
UTY-ABGX
UTY-VSGX
UTY-TEKX / UTR-YESA
UTG-UDYD-W
UTD-LF60KA
UTD-LF25NA
UTD-RF204
UTD-SF045T
UTZ-VXAA
- UTZ-VXGA
- UTR-YDZB
- UTR-YDZC
UTB-YWA
UTY-RNKY
UTY-RSKY
UTY-RHKY
UTY-LNHY
UTY-LRHYB1
UTY-CGGY
UTY-DCGY
UTY-DTGY
UTY-APGX / UTY-PEGX
UTR-EV09XB / UTR-EV14XB
UTG-UFYC-W
UTY-VGGXZ1
UTY-VLGX
UTY-TEKX
UTD-RS100
UTG-AGYA-W
UTG-BGYA-W
UTD-GXSA-W / UTD-GXSB-W / UTD-GXSC-W
-
UTZ-KXGA / UTZ-KXGB
UTZ-KXGC
UTZ-PX1BBA / UTZ-PX1NBA
UTR-DPB24T
UTD-SF045T
UTD-RF204
UTD-LF25NA
UTD-LF60KA
UTD-RS100
UTY-AMGX UTY-AMGX
UTY-ASGX UTY-ASGX
UTG-UGYA-W
UTB-YWC
TypeOptional Parts List
Simple Remote Controller
With operation mode
Long Life Filter
Flange
Refrigerant Piping PartsConnection Units
Separation Tube
UTR-BP54MA / UTR-BP90MA UTR-BP090X
For S series For J-II & V-II Series
Gas Pipe
Liquid Pipe
UTR-BP180X UTR-BP567X
UTR-CP567X
For V-II Series
Outdoor Unit Branch Kit
UTR-EV09XB / UTR-EV14XB
EV Kit
For V-II Series
For without EV Kit model(J-II & V-II Series)
For Compact Wall Mounted type
Gas Pipe
Liquid Pipe
Gas PipeLiquid Pipe
RB (Refrigerant Branch) Unit
UTF-Y54A1A UTF-Y90A4A
For S series
Single type Multi type
Header
UTR-HD906R UTR-HD908R
For S series
Headers are available for installation as necessary.
*Reducer is attached to each header kit.
Separation tubes are available for installation as necessary.
Gas Pipe
Liquid Pipe
Gas Pipe
Liquid Pipe
UTR-H0908L / UTR-H1808L* *For V-II Series onlyUTR-H0906L / UTR-H1806L*
Liquid Pipe
Gas Pipe
For J-II & V-II Series
155154
Optional Parts for VRF
Controllers / Adaptor & Convertor Panel / Service
Others
Panel Service
For Cassette type
For Duct type
For Ceiling type
UTZ-PX1BBA / UTZ-PX1NBA
Flange
UTD-RF204(Round)
UTD-SF045T(Square)
Auto Louver Grille Kit
UTD-GXSA-W (For 07/09/12/14 type)UTD-GXSB-W (For 18 type)UTD-GXSC-W (For 24 type)
Indoor unit950
Panel 600
600(mm) Panel spacer
242mm
UTG-UFYC -W UTG-UGYA-W
UTG-AGYA-W
Wide Panel
Air Outlet Shutter PlateShuts the air outlet when only using as 2 or 3 blow out.
UTG-BGYA-W
Panel Spacer
UTZ-VXAAFor Compact Cassette type
UTZ-VXGAFor Cassette type
Fresh Air Intake Kit
UTG-UDYD-W
UTZ-KXGA / UTZ-KXGB / UTZ-KXGC
Insulation Kit For High Humidity
For Compact Cassette type / Cassette type
Insulation Kit
Remote Sensor Unit
UTD-RS100
New amenity space can be offered by installing the Remote sensor.
Drain Pump Unit
UTD-LF60KA UTD-LF25NA
Long-Life Filter
Drain Pump Unit
UTR-DPB24T
Controllers for Individual Control
Controllers for Centralized Control
Adaptors &Convertors
System Controller
UTY-APGX / UTY-PEGX
Touch Panel Controller
UTY-DTGY
Monitor ModeMonitor Mode 10/11/2008 Thu. 02:20 PM
AllPassage
ScheduleSchedule
OperationOperation
DownDownUpUpTopTop IconIcon
Name SetTemp.
RCProhibitExpandExpand Status
Lobby
Passage
Entrance
Staff Room
PC Room
Heat
Heat
Auto
Mode
21.5˚C High
21.5˚C Med
Low
Fan
On
On
On
On
Off
Cool
24.0˚C
Auto26.0˚C
On/OffOn
AllModeTemp.TimerFilter
Mng´g Op ModeOP Restricted
ScheduleFilter Sign
MixedHeat
GroupError
Cool/DryAuto/Fan
RC Prohibition
SettingSetting
Cancel AllCancel All
Select AllSelect All
OnOn
OffOff
OnOn
OffOff
OnStatus: On
Central Remote Controller
UTY-DCGYUTB-YCA
Group Remote Controller
UTB-YDB / UTY-CGGY
External Switch Controller
UTR-YESA / UTY-TEKX
Signal Amplifier
Network Convertorfor LONWORKS®
UTR-YLLA / UTY-VLGX
BACnet® Gateway
UTY-ABGX
Network Convertor
UTR-YRDA / UTY-VGGXZ1
Wired Remote Controller
UTB-YUB /UTY-RNKY UTB-YRA / UTY-RHKYWithout operation mode
Simple Remote Controller Decoration Panel Service Tool Web Monitoring Tool
UTB-YPB / UTY-RSKYWith operation mode
UTY-LNHY
Wireless Remote Controller
UTB-YVB
IR Receiver UnitFor Cassette type
UTY-LRHYB1
CD-ROM (Software)
Software Protection Key
UTY-VSGX
UTR-YDZCFor Cassette type
UTR-YDZBFor Compact Cassette type
For Duct type
UTB-YWA / UTB-YWC
UTY-ASGX
CD-ROM (Software)
UTY-AMGX
CD-ROM (Software)
156
Thanks to efficient recovery of thermal energy lost during Ventilation, you can save an air-conditioning fee.
Thanks to a drastic reduction of load incurred by outside air,you can make air-conditioners more compact in parallel with the recovery of thermal energy.
In a cooling mode, a highly humid open-air is brought near to a dehumidified room atmosphere and then supplied. In a heating mode, a room humidity is transferred to the dry outside air and then supplied.
The ducts of the unit and the heat exchange element are characteristic of sound shield effect, so that the office and store environment can be preserved.
High efficiency and low noise are achieved using a highly efficient element.Comfortable air-conditioned environment is provided by effectively determining whether to use heat-exchange ventilation or normal ventilation while meeting diverse needs.
Suppresses indoor temperature changes while providing fresh air
Energy Recovery VentilatorMore Comfortable Air Conditioning
159158
Energy Recovery Ventilator
81059931514260065519
27013515988241495
219144
Energy consumption is dramatically reduced by using a counter-flow heat-exchange element. Air conditioning load is reduced by approximately 20%, resulting in significant energy savings. Recovers up to 77% of the heat in the outgoing air.
With the cross-flow element, air moves in a straight line across the element. With the counter-flow element, air flows through the element for a longer time (longer distance), so the heat-exchange effect remains unchanged.
High Efficiency
Energy efficiency and ecology
Features of heat exchange element
Easy Installation and Maintenance
Counter-flow heat exchange element used for reduced noise and slimmer, more compact body shape.
Slim shape and easier installation
Adoption of straight air supply / exhaust system: Duct design is simplified because the air supply / exhaust ducts are straight.Since each unit can be mounted in reverse position, only one inspection hole is needed for two units: Two units can share one inspection hole so duct work is easier and more flexible.
Reverse mountable direct air supply / exhaust system
More Comfort
Significantly reducing low pressure loss and noise allows low-noise operation of 32 dB (High) or less for models with a capacity of 500 m3/h or less, and 37.5 dB (High) for models with a capacity of 1,000 m3/h.
Quiet operation
Cleaning reduced due to the special material heat exchanger. The nylon/polyester fibre filter offers high dust retention capacity.
Long heat-exchanger service life
Other element(Cross-flow element)
Fujitsu element(Counter-flow element)
Straightunit
Reversemounted unit
Outside airExhaust air Exhaust air
Supply airRoom air Room air
UTZ-BX025A/BX035A/BX050A
Height
270mm
20%Energy saving
UTZ-BX080A/BD100A
Height
388mmInspection
hatch
Inspectioncover
Specifications
* The noise level must be measured 1.5 m below the centre of the unit.
Dimensions (Unit : mm)Models: UTZ-BX025A / UTZ-BX035A / UTZ-BX050A / UTZ-BX080A / UTZ-BD100A
Maintenance space
Maintenance opening
UTZ-BX025AABCDEFGHIJKLMNO
81080448016260086019
27014515988241495
219144
UTZ-BX035A89090450020260096019
270145159962414107246194
UTZ-BX050A1,25088442822860094019388194218
1,32261285258242
UTZ-BX080A1,2501,134678228600
1,19019388194218
1,32261285258242
UTZ-BD100A
UTZ-BX080A UTZ-BD100A
UTZ-BX025A UTZ-BX035A
UTZ-BX050A
Energy recovery ventilator unit offers maximum comfort and greater energy savings.
Input powerAir flow rateExternal static pressure
Hea
t E
xcha
nge
Vent
ilatio
nN
orm
al
Vent
ilatio
n
DimensionsWeightOutlet duct diameterOperation rangeMaximum humidity
Rated flow rate
Model No.
250 m3/h
UTZ-BX025A
220-240V , 50Hz
350 m3/h
UTZ-BX035A
500 m3/h
UTZ-BX050A
800 m3/h
UTZ-BX080A UTZ-BD100A
1000 m3/h
Power sourceW
m3/hPa
%
%
%
dB*
dB*
Wm3/hPa
mmkg
°C%
mm
(Extra high)/High/Low(Extra high)/High/Low(Extra high)/High/Low
(Extra high)/High/Low(Extra high)/High/Low(Extra high)/High/Low(Extra high)/High/Low(Extra high)/High/LowW×D×H
(Extra high)/High/Low
(Extra high)/High/Low
(Extra high)/High/Low
Adopts a highly efficient counter-flow heat exchange element
Heat exchanger Outside air
Exhaust air
Supply airRoom air
Heat exchange ventilationWhen a room is cooled or heated, the exhausted cooling / heating energy is recovered by heat-exchange ventilation.
Normal ventilationThis is used in the spring and autumn, when rooms are not cooled or heated, that is, when there is little difference between the indoor and outdoor air conditions. In addition, at night during the hot season, when the outside air temperature drops the outside air is drawn inside without heat exchange, alleviating the load on the air conditioning equipment.
Heat exchange ventilation and normal ventilation
119 / 99 / 79250 / 250 / 170
90 / 80 / 37
154 / 124 / 117350 / 350 / 280
95 / 65 / 42
214 / 169 / 151500 / 500 / 370
105 / 70 / 38
347 / 309 / 302800 / 800 / 650140 / 110 / 70
445 / 360 / 3321,000 / 1,000 / 810
90 / 55 / 35
75 / 75 / 77
63 / 63 / 66
70 / 70 / 73
28 / 26 / 21119 / 98 / 79
250 / 250 / 17090 / 80 / 37
27 / 26.5 / 21.5882×599×270
29150
-10 to 4085
75 / 75 / 77
66 / 66 / 69
69 / 69 / 71
32 / 29 / 25151 / 119 / 113350 / 350 / 280
95 / 65 / 4231 / 30 / 26
882×804×27037
150-10 to 40
85
75 / 75 / 76
65 / 65 / 68
71 / 71 / 74
38 / 36.5 / 32337 / 300 / 297800 / 800 / 650140 / 110 / 7038.5 / 37 / 33
1,322×884×38871
250-10 to 40
85
75 / 75 / 76
65 / 65 / 68
71 / 71 / 73
37.5 / 36 / 31438 / 358 / 329
1,000 / 1,000 / 81090 / 55 / 35
38 / 36.5 / 31.51,322×1,134×388
83250
-10 to 4085
75 / 75 / 77
62 / 62 / 67
67 / 67 / 71
34 / 31 / 25210 / 161 / 145500 / 500 / 370
105 / 70 / 3834 / 32 / 26.5962×904×270
43200
-10 to 4085
Sound pressure levelInput powerAir flow rateExternal static pressureSound pressure level
Temperature ExchangeEfficiencyEnergy ExchangeEfficiency Cooling
Energy ExchangeEfficiency Heat pump
160
Capacity
EER - Energy ClassCOP - Energy Class Running CurrentMoisture Removal
Air Flow (High)Noise (Indoor)
Net Dimension H x W x D
Operation RangeCooling
Super PowerSuper QuietSuper WaveInstant Air Exchange
HeatingRefrigerant
Feature
HeatingCooling/HeatingPower Consumption
Power SourceCooling
Cooling
Indoor / OutdoorCooling
HeatingCooling/Heating
°CDB
kW
kg(lbs)
A
W/W
m3/h
I/hdB(A)
mm
V/ Ø/Hz
kW
21~430~21
Model No. AFY16UA
230/1/504.554.30
1.81/1.622.51-E2.65-E8.0/7.2
2.156.5/51.5
620400x660x633
61(134)
R410A
For AFY Models
Minimum
140° Maximum
Swing
Unrestricted direction of airflow. The louver allows airflow coverage as wide as 140°. Mounting the louver in the center provides coverage of an area as wide as 140°. Cold or warm air is distributed throughout the room.
The filter can be cleaned without removing the front panel.
H/L
Quickly transforms your roominto an oasis
AFY16UA
Specifications
Window type Air ConditionersCompact, High Power, and Low Noise
162
Complete Solution meets various needsThe clean energy produced by reliably delivers “comfort” to diverse spaces in the home up to the living room, bedrooms, bath and swimming pool.
is an Economical and Clean hot water heating system by Heat Pump
RadiatorDomestic hot water
Swimming pool
Floor heating
Domestic hotwater tank
Absorbing the free energy from atmosphere. Heat pump system requires only 1kW of electricity to generate 3 to 5 kW thermal energy.
1 kWhelectricity
Heat pump system
3 to 5 kWhof heat
Comfort heating
2 to 4 kWhAmbient air
High Power
Comfort
Compact
164
164
165
165164
•2 Zone individual control (2 under floor heating zones or under floor heating + radiator zone, etc.)*
Indoor unit
*Optional parts are required.
Radiator
Floor heatingValve
Pump
Pump
Outdoorunit
~50°C
~35°C
2nd Circuit Kit
2 Zone individual control
2 Zone individual control
High leaving water temperature of 60°C keeps to -20°C of outdoor temperature without using backup heater.
-10-15 -5 0 5
40
-20
50
60
Leav
ing
wat
erte
mpe
ratu
re (°
C)
Powerful Heating & High Efficiency
High leaving water temperature
High Power model
Comfort model
High COP
Air to water heat pumps work with much more efficiency and save more energy than a traditional heating system.
4.30
3.90
High Power model
Comfort model
*The data refer to 16kW type Condition : Outdoor Temp. 7°C Heating Temp. 35°C.
Intelligent Control
High Reliability
High clean and durability
•Corrosion protected •No fouling through heat exchanger construction•Hot water is permanently available
Highly efficient water heat exchanger
Double-pipe water heat exchanger with built-in tank to reduce loss
Stainless steel buffer tank
Optimum co-axial heat exchanger
Anti-freeze is unnecessary
Warm refrigerant flow
Heated water
Compact model
WPYA080LAWPYA100LA
UTW-SCBYAControl box
High Power modelSPLIT TYPE SPLIT TYPE MONOBLOC TYPE
Comfort model
Indoor unitIndoor unitWSYA050DAWSYA065DAWSYA080DA
WSYG140DB6WSYK160DA9
WSYA095DAWSYA128DAWSYA155DA
AOYA18LALLAOYA24LALL
AOYA45LBTLAOY54LJBYL
WOYK112LATWOYK140LATWOYK160LAT
WOYG112LBTWOYG140LBT
Outdoor unit
Monobloc unit
Outdoor unit
AOYA30LBTL
Nobackupheater
Nobackupheater
Outdoor temperature (°C)
Outdoor temperature (°C)
-10-15 -5 0 5
40
50
60
-20
55
Leav
ing
wat
erte
mpe
ratu
re (°
C)
High COP is realized by using a DC twin rotary compressor, inverter technology, and high efficient water heat exchanger.
4.50
4.35
8 kW
10 kW
High COP
*Condition : Outdoor Temp. 7°C Heating Temp. 35°C.
High Reliability
Anti-freeze function
Water circulation and compressor can be automatically performed at low outdoor temperature. Freezing of circulated water can be prevented.
•No installation of refrigerant circuit connections.•Closed type enables decrease in the supply frequency of circulating water.
•Easy access for maintenance operations
Easy installation & maintenance
Time
ON OFF
High
Low
Anti-freeze mode
Outdoor temperature
Settingtemperature
Wired remote controller(control box) is adopted standard.
Intelligent Control
High leaving water temperature of 55°C keeps to -20°C of outdoor temperature without heater.
Compact & High Performance
High leaving water temperature
•Automatic heating curve control•Cooling operation is possible*•Anti-Legionella function•Possible to docking the boiler and electric heater for backup
Twin Rotary Compressor with Linear Control Injection port
Injection port
FUJITSU GENERAL’s advanced Linear Control Injection Technology (High Power model)
Control box
Compact & light weight design
850 mm
330 mm
Weight
82kg88
1.5
mm
*Optional parts are required.
And more
It realizes the high condensing temperature without overheating discharge gas temperature by Linear Control Injection process during compression.
Linear Control Injection
Normalrefrigerantcircuit
High compression
167166
Smart & Comfort Control
Optional parts
UTW-KBSXA
Boiler Connection Kit
UTW-KCLXA
Cooling Kit
UTW-KCHXA
UTW-KDWXA
DHW Kit
UTW-KZSXA
2nd Circuit Kit
UTW-TEVXA
UTW-T20XA
DHW Tank200L
UTW-T30XA
DHW Tank 300L
UTW-KSPXA
Swimming Pool Kit
UTW-ESPXA
Heat exchanger for swiming pool
UTY-XWZXZ2
External Indication Kit
High Flow Rate Circulating Pump Kit
UTW-C75XA UTW-C55XA
Remote Control Room Thermostat
UTW ESPXA
g p
UTW KBSXA
UTW-KDWXA
HW Kit
Balancing Vessel
Cooling Kit (High flow rate)
UTW-PHFXA
Comfort
Flexible heating circuit
Automatic hot water temperature control matched to the application can be set. In addition, set temperature coefficient offset can be adjusted easily high or low side matched to the usage conditions.
Simple operation mode setting•Selecting the heating mode
Large LCD display•Operation status display•Error display / Error history
Navigation and setting•Selecting the heating menu
•Setting program timerThe growth of Legionella in DHW tank is suppressed and safe and clean hot water is supplied at all times.
Optional remote controller allows controls of hot water depending on indoor temperature.
Comfort/Reduce mode switching automatically according to outdoor temperature
Anti-legionella function
Remote control-extension
Programmed operation
Automatic mode
Day-Weekly timer setting
Heating mode
•The setting of programmed operation can be easily set.•Changing the heating mode linked with time is possible.
•The day-weekly timer can be set up for up to 3 times per day.•Allows separate settings for each day of the week.
Holiday timer setting•The holiday timer can be set up for up to 8 periods
•If you are absent for a long time in the winter, freezing of room can be prevented.
Convenience
Outdoor temperature (°C)Low High
High
Low
+4.5°C
-4.5°C
6 9 12 15 18 21 24Time
Monday-Friday
Setting heating curve
11 12 1 2 3 Date
Holiday timer Day-Weekly timer
Leav
ing
wat
erte
mpe
ratu
re (°
C)
Constant comfort temperature
Comfort mode
Constant reduce temperatureReduce mode
Stand-by mode with anti-frost protection
Protection mode
6 9 12 15 18 21 24Time
Saturday-Sunday
Room Thermostat(Option)
Remote Control(Option)
Outdoor unit
Indoor unit
orFloor heating Radiator
(Split type)
OutdoorSensor
Extendibility
Installation example The water heating system can be freely constructed for a wide range of applications from floor heating to hot water showers.
Design Versatility
Indoor unit
Boiler
Radiator
Valve
Valve
Valve
Pump
Pump
Tank
Outdoorunit
Under floor heating
Hot water showerIndoor unit
RadiatorValve
Valve
Pump
Pump
Tank
Outdoorunit
Under floor heating
Hot water shower
Indoor unit
Outdoorunit
Under floor heating
Indoor unit
Radiator
Valve
Pump
Pump
Outdoorunit
Under floor heating
3 types of heat distribution System for low outdoor air temperatures (additional heating boiler connection)Under floor heating + Radiator + Sanitary hot water
Single heating systemUnder floor heating
2 system simultaneous heating (Individual control)
Under floor heating + Radiator
Under floor heating + Radiator + Sanitary hot water
Meets diverse needs by combining with optional parts.
Diverse operation control
OPTIONS
2-temperature simultaneous heating Floor heating + Radiator heating(Split type only)
Operation together with boiler at low outdoor temperature
Temperature control of swimming pool (Controlled at 35°C)
169168
DimensionsSpecifications (Unit : mm)
Indoor Units Comfort model
Compact model
Indoor Units High Power model
WSYA050DA / WSYA065DA / WSYA080DA WSYA095DA / WSYA128DA / WSYA155DA
Outdoor Units Comfort modelAOYA45LBTL / AOY54LJBYLAOYA30LBTLAOYA18LALL / AOYA24LALL
WPYA080LA / WPYA100LAControl BoxUTW-SCBYA
66790
10
300
578
347
77900
830
21
33031 12
400
Outdoor Units High Power modelWOYK112LAT / WOYK140LAT / WOYK160LAT
WOYG112LBT / WOYG140LBT
540155 155
90 60275
330
240
522.
533
5110
180
881.
5
116
357
850
436 152
171
1290
900
21
33031 12
400
48088
235
450
1034
1000
ØM26x34 ØM26x34
WSYG140DB6 / WSYK160DA9
1290
900
21
33031 12
400
77
1290
900
21
33031 12
400
77
Outdoor unit
Capacity range (kW)Series name
Input powerCOP
+7°C / +35°C floor heating
-7°C / +35°C floor heating
+7°C / +45°C radiators
-7°C / +45°C radiators
Input powerCOP
Input powerCOP
Input powerCOPCapacityBackup heater
Dimensions H×W×DWeight (Net)Buffer tank capacityExpansion vessel capacityLeaving water temperature range
Rated
Flow / ReturnWater pipe connection diameter
Indoor unit Model name
Model name
Heating capacity
Heating capacity
Heating capacity
Heating capacity
Power source
Power source
Current
Noise level (Sound pressure)Dimensions H×W×DWeight (Net)Refrigerant
Operation range
Connectionpipe
Diameter
Water circulation
kW
kW
kW
kW
kW×pcs.
mmkgLL
L /min
°Cmm
A
dB(A)mmkg
kg
mmm°C
mmmm
Comfort seriesType Split system
High Power series
RatedMax
LiquidGasMini / MaxMaxMaxHeating
LengthLength (chargeless)Height difference
Capacity range (kW)Series name
kWInput powerCOP
+7°C / +35°C floor heating
-7°C / +35°C floor heating
+7°C / +45°C radiators
-7°C / +45°C radiators
kWInput powerCOP
kWInput powerCOP
kW
mmdB(A)
A
Input powerCOP
Dimensions H×W×D
Rated
kg
kg
Noise level (Sound pressure)Current
Monobloc unit Model name
Heating capacity
Heating capacity
Heating capacity
Heating capacity
L
Power source
L /min
°C
mm
Water circulation
Type
Weight (Net)Expansion vessel capacity
Leaving water temperature range°COperation range
Water pipe connection diameterRefrigerant
Monobloc systemCompact series
1Ø 230V, 50Hz
881.5 × 850 × 330828
Ø25.4 / Ø25.4
8 ~ 55-20 ~ 35
R410A1.5Refrigerant amount
Rated
Heating
+2°C / +35°C floor heating
Input powerCOP
Heating capacitykW
+2°C / +35°C floor heating
kWInput powerCOP
Heating capacity
Mini / Max
Mini / Max
Flow / Return
Refrigerant amount
*2
8
WPYA080LA
8.001.784.507.402.732.717.102.932.427.802.233.506.502.982.18
22.910.0 / 30.0
518.30
*2
1111.202.514.46
11.203.922.86
11.203.453.25
10.502.903.6210.504.162.52
9.0(3.0 × 3 pcs.)
3.608.50
32.120.0 / 40.0
53*2
1616.003.724.30
15.005.552.70
15.104.423.42
14.506.382.27
9.0(3.0 × 3 pcs.)
15.104.873.10
5.5010.50
45.928.3 / 56.7
56*2
AOYA18LALL
10.80
578 × 790 × 30040
201.25
Ø6.35Ø12.705 / 15
1515
39*3
R410A
1034×450×48052.5258
1Ø 230V, 50Hz
1Ø 230V, 50Hz
-15 ~ 24
Ø25.4 / Ø25.48 ~ 50
1414.003.224.35
14.005.152.7213.103.703.5413.105.392.43
9.0(3.0 × 3 pcs.)WSYK160DA9
14.004.40
4.809.50
1290 × 900 × 33099
R410A
50Ø9.52
Ø15.885 / 20
1515
40.125.0 / 50.0
1034 × 450 × 48053
258
Ø25.4 / Ø25.4
3Ø 400V, 50Hz
3Ø 400V, 50Hz
2.50
3.18
55*2
8 ~ 60
1010.002.304.35
WPYA100LA
8.103.002.708.003.322.419.802.883.407.003.312.11
28.710.0 / 30.0
51*210.20
Additional refrigerant charge amount g/m
54.601.074.30
4.801.772.704.171.23
4.05
3.0(1.5×2 pcs.)WSYA050DA
4.311.363.16
5.16
14.39.0 / 18.3
3.38
1.782.28
6.501.634.00
5.602.242.505.401.613.355.102.322.20
3.0(1.5×2 pcs.)
6
WSYA065DA
18.610.0 / 23.3
7.25
5.592.052.73
1010.302.584.00
8.103.522.308.302.513.307.003.332.10
6.0(3.0×2 pcs.)WSYA095DA
27.216.7 / 35.0
10.40
64
40Ø9.52
Ø15.885 / 20
2020
AOYA30LBTL
2.20
830×900×33055*2
16.00
8.693.212.71
55
13
Ø9.52Ø15.885 / 20
2020
13.703.424.00
11.554.372.649.702.983.269.204.302.14
6.0(3.0×2 pcs.)WSYA128DA
36.725.0 / 50.0
13.70
1290×900×33098
50
AOYA45LBTL
3.35
*219.00
12.313.873.18
16
Ø9.52Ø15.885 / 20
2020
16.204.153.90
12.404.772.60
13.304.203.17 11.005.372.05
6.0(3.0×2 pcs.)WSYA155DA
44.425.0 / 50.0
17.10
55.5
105
40
AOY54LJBYL
3.40
1290×900×330
24.50
13.944.772.92
88.00
7.002.542.756.201.883.305.902.622.25
3.0(1.5×2 pcs.)WSYA080DA
8.2711.22
44
20Ø6.35
Ø15.885 / 15
1515
AOYA24LALL
6.392.342.73
1.70
22.914.3 / 28.3
578×790×31540*3
2.004.00
55
11
6.0(3.0 × 2 pcs.)
11.20 2.54 4.40 11.203.54 3.16 11.204.16 2.69 9.60 2.77 3.46 9.60 4.12 2.33
32.120.0 / 40.0
*2 56
14
6.0(3.0 × 2 pcs.)
14.00 3.25 4.30 14.00 4.51 3.10 14.00 5.47 2.56 12.00 3.50 3.42 12.00 5.32 2.26
40.125.0 / 50.0
*2
1Ø 230V, 50Hz
1Ø 230V, 50Hz
WSYG140DB6
52
92
10.8 13.721.0 24.0
-25 ~ 35
WOYK112LAT WOYK160LATWOYK140LATWOYG112LBT WOYG140LBT
*1
*1
*1
*1
*1
*1
*1
*1
*1
*1
*1. The values of heating capacity/power input/COP are based on measurement of EN14511 standard.
Usage environment, such as operation of the heating equipment, room temperature, and controller adjustments, may cause disparities between practically determined and these values.
*2. Sound pressure level measured at distance of 1m from the device and at a height of 1.5m above ground in free field
*3. Sound pressure level measured at distance of 5m from the device and at a height of 1.5m above ground in free field
170
This solves your problems with distracting lifestyles smells and other stubborn smells.
*1. Compared to our Model ACS-24NVU Air Cleaner using urine (substituted with ammonia), food and raw garbage (fermented beans used as compound odour). However, approximately 50 times the deodorising capability (our company’s study) for faecal waste (skatol and compound odour). Tested with constantly emitted odour. Calculated from the fact that the balance ratio of concentration for the same generation volume with the concentration of odour intensity level 1 as 10 times is inversely proportional to the removal capability.*2. Test organization: Kitasato Research Center of Environmental Sciences. Checked in UV deodorant system. *3. Washing with water once a year is the standard when cleaned with a vacuum cleaner once a month. (The cleaning frequency can vary depending on the conditions of use in the home. Replacement may also be necessary, depending on the condition of use.)
173172
Washable
1 2 3 4 5
Automatic deodorisationcapability regeneration
2 WORLD FIRST functions.
UV deodorant system
High Performance Verification Test Results
Removes permeated odours
The deodorising component*5 (weak ozone) discharged from the body decomposes and deodorises odours permeating the room from their source.
DASY30S
Automatic deodorisationcapability regeneration system
Powerfully removes odours by the world’s first deodorisation decomposition technology.Simultaneously displays air cleaning and bacteria elimination effects, and makes living more pleasant.
WirelessRemote
Controller
*1 *1
Odour intensity : 5. Very strong odour 4. Strong odour 3. Easily sensible odour 2. Weak odour but type of odour is sensed 1. Slightly sensible odour 0. No odour
00
:Home air cleaner ACS-24NUV :Natural loss
1
2
345
5 10 15
Pet, human waste odour
Concentration differenceapprox.
(Fujitsu General rate)150 times
Concentration differenceapprox.
(Fujitsu General rate)
*3 150 times
Raw garbage odour (Change of stray virus in 1m3 box)
:AIR DEODORISER DASY30S
0
1009080706050403020100
(%)
105 15 20 25
Comparison of deodorising performance Virus elimination rate
:AIR DEODORISER DASY30S
Odo
ur in
tens
ity
Odo
ur in
tens
ity
Viru
s su
rviv
al ra
te
(minute)(minute)
00
1
2
345
5 10 15(minute)
99.98% removed
*4
Image of filter regeneration by heating operation
Rem
oval
rate
(%)
Operation time (hours)
0
100
0 12 24 36
Change of removal rate when heating operation was performedChange of removal rate without heating operation30 minutes heating operation approximately every 12 hours
Recovering original deodorising ratio in 30 minutes
Large volume of ozone is generated by light (185nm). Ozone power decomposes odour molecules.
Powerful deodorisation &bacteria elimination by 3 wavelengths
Photo catalytic deodorisationOdour molecules are decomposed by illuminating a titanium oxide plate with light (254nm).
Ozone deodorisation
Bacteria eliminationBacteria and virus are repelled by light (185nm) having a bacteria elimination power 1600 times that of sunlight.
*2Deodorisation capability regenerated by heating
*3
Specifications
Odo
ur in
tens
ity
0
deodorising component1
2
345
Time elapsed (hours)0 1 2 3 4
Natural elimination
Deodorising effect of a piece of cloth permeated with the odour of 10 cigarettes6 stage odour intensity method (test room of 13.2m2)
*1. Home air deodorisation machine announced November 7, 2005. *2. Generates light of 3 wavelengths; ozone generation 185nm, bacteria elimination 254nm, and photo catalyst activation 365nm. *3. Compared to our Model ACS-24NVU Air Cleaner using urine (substituted with ammonia), food and raw garbage (fermented beans used as compound odour). However, approximately 50 times the deodorising capability (our company’s study) for faecal waste (skatol and compound odour). Tested with constantly emitted odour. Calculated from the fact that the balance ratio of concentration for the same generation volume with the concentration of odour intensity level 1 as 10 times is inversely proportional to the removal capability. *4. Test organization: Kitasato Research Center of Environmental Sciences. Checked in UV deodorant system. *5. Generates very weak ozone. However, the concentration is less than the volume existing in the natural state in forests, etc. The deodorising effect varies depending on the room size and amount of ventilation. *6. Test organization: Tested by Shinshu University using lice carcass, lice faeces, cat epidermis, dog epidermis, and orchard grass. *7. Washing with water once a year is the standard when cleaned with a vacuum cleaner once a month. (The cleaning frequency can vary depending on the conditions of use in the home. Replacement may also be necessary, depending on the condition of use.) • Photographs and illustrations are images. • Harmful substances (carbon monoxide, etc.) of tobacco cannot be removed.
Air cleaning capability
Air is cleaned by powerful dust collection.
Prefilter: Removes pet hair and large dust particles.Allergenic substance decomposition dust collection filter: Removes pollen, lice, and other allergenic substances*6
Dust Cat and dogepidermis
Pollen(Orchard grass)
Lice(Carcass, droppings)
Filter replacement unnecessary*7
All filters do not require replacement. Economical
Washable. Replacement unnecessary.1. Prefilter2. Allergenic substance decomposition dust collection filter
Automatic deodorisation capability regeneration. Maintenance-free3. Heater unit4. Compound metal oxidation catalyst honeycomb filter5. Special activated charcoal filter
VHz
m3/mindBWm3
220-24050/60
AUTO, QUIET, HIGH, HI-POWERAt minimum 0.8, at maximum 3.0At minimum 19, at maximum 45At minimum 11, at maximum 35
Non-woven fabric pleat filterUV ozone + compound honeycomb
Bacteria elimination lampCatalytic honeycomb filter: Automatic refreshingDust collection filter: Water washing refreshing
Gas sensorInverter
1274 x 653 x 215
6.4Floor installation (wall mounting bracket installable)
2Overcurrent prevention (current fuse)
Excessive temperature rise prevention (automatic reset thermostat)Excessive temperature rise prevention (temperature fuse)
Accessory
Model No. DASY30S
h
kg
m
mm
~33 *By amount of generation source
•Oxidation and decomposition capability is promoted by heating the filter for 30 minutes every 12 hours.
•Initial performance is maintained by removing odour molecules clinging to the filter.
Power consumptionApplicable floor spaceDust collection functionDeodorising methodBacteria elimination method
Filter life
SensorMotor driveOff timerProduct outside dimensionsProduct weightInstallationPower cord length
Safety devices
Remote controller
Operating soundAir flowOperation modes
Rated voltage
175174
Feature Explanation
Comfortable function Feature summary
Com
fort
able
func
tion
Con
veni
ent f
unct
ion
Cle
an fu
nctio
n
Double swing automaticComplex swing action of flaps enables automatically to swing both horizontal and vertical directions.
Up / down swing flapsThe up/down flaps automatically swing up and down.
Auto restartIn the event of a temporary power failure, the air conditioner will automatically restart in the same operating mode as before, once the power supply is restored.
Auto-changeoverThe unit automatically switches between heating and cooling modes based on your temperature setting and the room temperature.
10°C HEAT operationThe room temperature can be set to go no lower than 10°C, thus ensuring that the room does not get too cold when not occupied.
Automatic air flow adjustmentThe micro-computer automatically adjusts the air flow effectively to follow the changes of room temperature.
Convenient function
Sleep timerThe micro-computer gradually changes the room temperature automatically to afford a comfortable night's sleep.
ON-OFF timerON-OFF timer can be set to operate once.
Program timerThis digital timer allows selection of one of four options: ON, OFF, ON OFF or OFF ON.
Weekly timerDifferent on-off times can be set for each day.
Weekly + setback timerWeekly + Setback timer can set temperature for two times spans and for each day of the week.
Filter signIndicates the filter cleaning period by lamp.
Economy modeLimits the maximum operation current, and performs operation with the power consumption suppressed.
Powerful modeOperation at maximum air flow and compressor speed, and quickly makes the room comfortable.
Low Noise ModeSound noise level of outdoor unit can be selected.
Connectable fresh air duct
Fresh air intakeFresh air can be taken in by a fan which can be connected using external control unit.
Connectable distributing duct
Energy saving modeThis mode raises the set temperature slightly in the cooling mode and lowers the set temperature in the heating mode to economically control the operation of the unit.
Automatic filterThe filter is automatically cleaned after the time is set for the air conditioner.
UV filter cleanerUV (ultraviolet rays) suppresses the growth of mold and germs inside the indoor unit.
The filter deodorizes by powerfully decomposing absorbed odors using the oxidizing and reducing effects of ions generated by the ultra-fine-particle ceramic.
Apple-catechin filterFine dust, invisible mold spores, and harmful microorganisms are absorbed onto the filter by static electricity, and further growth is inhibited and deactivated by the polyphenol extracted from apples.
Coil dry
Washable panel
Clean function
Long-life ion deodorization filter
The indoor unit can be dried to prevent the growth of mold and bacteria.
i-PAM control models
V-PAM control models
Up / down swing flaps
Wall Mounted
FloorCeiling Wall
Compact Cassette / Cassette
Floor/Ceiling UniversalCeiling
Slim Duct
Compact Duct / Medium Static Pressure Duct
High Static Pressure Duct
Double swing automatic
Automatic air flow adjustment
Auto restart
Auto-changeover
10°C heat operation
Connectable distributing duct
Connectable fresh air duct
Fresh air intake
Economy mode
Sleep timer
On-off timer
Program timer
Weekly timer
Weekly + setback timer
Filter sign
Automatic filter cleaner
UV filter cleaner
Long-life ion deodorization filter
Apple-catechin filter
Coil dry
Washable panel
AWYZ14LB/18LB/24LB
ASYG09LT/12LT
ASYG07LU/09LU/12LU/14LU
ASYG18LF/24LF/30LF
ASYG07LE/09LE/12LE/14LE
ASY7UB/9UC/12UC
ASY18UB/24UB/30UB
AGYF09LA/12LA/14LA
AUYG12LVLB/14LVLB/18LVLB/AUYF24LB
AUY18UB
AUYA30LB/36LB/45LC/54LC
AUY25UU/30UU/36UU/45UU/54UU
ABYG18LVLB/ABYF24LB
ABY18UB/24UB
ABYA30LB/36LB/45LC/54LC
ABY30UB/36UB/45UB/54UB
ARYG12LLTB/14LLTB/18LLTB
ARY18UU
ARYF24LB/ARYA30LB/36LB/45LC
ARY25UU/30UU/36U(1)/36UU/45UU
ARYC45LC/54LC
ARY60UU
ARY90TL
(12/14/18) (18)
: Optional function
Energy saving mode
Human sensor
Low Noise modeLow noise
Powerful modePOWERFULPOWERFULPOWERFUL
Human sensorHuman sensor catches movements of people in a room.
Low noise
POWERFULPOWERFULPOWERFUL
(45/54) (45) (45)
Recommended