View
222
Download
0
Category
Preview:
Citation preview
Page 1 of 27 Ford UIM Ford Motor Company
FORD MOTOR COMPANY
UPFITTER INTERFACE MODULE (CAN INTERFACE MODULE [CIM])
USERS GUIDE
(VERSION 1.0)
Page 2 of 27 Ford UIM Ford Motor Company
TABLE OF CONTENTS 1.0 INTRODUCTION ............................................................................................................................................................ 3 1.1 Product Overview ........................................................................................................................................................ 3 2.0 PACKAGE LOCATION ................................................................................................................................................. 5 2.1 Refer to vehicle owner’s manual, BEMM or your local dealership ............................................................................ 5 3.0 INPUT(S)/OUTPUT(S) DEFINITION AND REQUIREMENTS ................................................................................ 6 3.1 Input Switch Requirements ......................................................................................................................................... 6 3.1.1 Electrical Requirements .............................................................................................................................................. 8 3.2 Outputs ........................................................................................................................................................................ 9 3.2.1 External Relay Configuration ...................................................................................................................................... 9 3.2.1.1 High Side Driver Relay Configuration ........................................................................................................................ 9 3.2.1.2 Low Side Driver Relay Configuration ........................................................................................................................ 9 3.2.2 LED application ........................................................................................................................................................ 10 3.2.2.1 High Side Driver LED application ............................................................................................................................ 10 3.2.2.2 Low Side Driver LED Application............................................................................................................................ 11 3.3 Application Examples ............................................................................................................................................... 11 3.3.1 Coupling of Logic Blocks Using External Wiring .................................................................................................... 11 3.3.2 Upfitter Application Example Using Input and Hall Effect Switches, and Relay Outputs: ...................................... 13 4.0 CONNECTOR PIN OUT AND WIRING .................................................................................................................... 14 4.1 Connectors - The UIM has 3 Molex Connectors ....................................................................................................... 14 4.1.1 8-way Vehicle Connector (Black). Key Way A. Molex Part# 34728-0080. ............................................................. 14 4.1.2 Wiring Harness – 16-way Output Connector (Black). Key Way A. Molex Part# 34728-0160................................. 16 4.1.3 Wiring Harness – 16-way Input Connector (Grey). Key Way B. Molex Part#34728-0161. ..................................... 17 4.2 Wiring Harness (Part# HC3T-14G303-D*) .............................................................................................................. 18 5.0 GENERAL ELECTRICAL SPECIFICATIONS ........................................................................................................ 19 5.1 The UIM I/O Specifications ...................................................................................................................................... 19 5.1.1 Inputs ......................................................................................................................................................................... 19 5.1.2 Upfitter Interface Module Output Electrical Requirements: ..................................................................................... 20 5.1.3 Upfitter Interface Module Power Requirements ....................................................................................................... 20 5.1.4 Upfitter Interface Module Ground ............................................................................................................................. 20 5.1.5 Standard USB 2.0 Interface. ...................................................................................................................................... 20 5.1.6 Environmental Requirements .................................................................................................................................... 20 6.0 TROUBLE SHOOTING ................................................................................................................................................ 21 7.0 APPENDIX ..................................................................................................................................................................... 26 7.1 Appendix A – Definitions ......................................................................................................................................... 26 Revision Record .................................................................................................................................................................... 27
Page 3 of 27 Ford UIM Ford Motor Company
1.0 INTRODUCTION
This guide defines some general electrical/mechanical hardware and software interfaces including UIM Project Editor for the 2018 UPFITTER INTERFACE MODULE (UIM) also known as CAN INTERFACE MODULE (CIM) (depending on market) and is intended to provide specification guidelines. Some key design requirements may be included as a reference. It should be noted that any reference to UIM is interchangeable with CIM, both terms refer to the same module. 1.1 Product Overview The UIM is an electronic control module that has the ability to operate equipment (such as lift buckets, cranes, motors, salt spreaders, snow plows, etc.) with external automotive grade relays via customer programmable logic based on switch inputs and CAN signals. The operation of such equipment is limited to the load parameters of the UIM. The User shall not exceed those load limits. Refer to sections 4, 5, and 6 in this document. The UIM has 11 configurable inputs which can be configured and wired by the customer as either Active Low Input (module output is activated when the module control input circuit has continuity to ground) or Active High Input (module output is activated when the module control input circuit receives power). Inputs 10 -11 are active low only or may be used as a 3-wire digital Hall Sensor Input (dedicated Ground, Input, and Feed). The UIM has 8 high side driver outputs and 7 low side driver outputs. The UIM is connected to the vehicle CAN bus, providing UIM application access to selected signals, and allowing OBD II diagnostic access to the UIM. The UIM is configured using the UIM Project Editor, which is compatible with Windows 7, and Windows 8 Operating Systems. The user must obtain the UIM Project Editor installation package by downloading it from the Ford Website (see vehicle specific owner’s guide *see note). The UIM Project Editor allows the user to program the application logic for each UIM output based on UIM inputs and CAN signals. A standard Type B Universal Serial Bus (USB) 2.0 cable is required (not included) to connect the user’s PC to the UIM, to download the application logic.
FORD Part Numbers:
Ford Part Steering Wheel Location Part Number
Upfitter Interface Module Left Hand Drive JK2T-14G589-A*
Upfitter Interface Module Right Hand Drive JK2T-14G589-B*
Blunt Cut Jumpers x 2 N/A JK2T-14A303-C*
Note the second character (*) of the suffix will be dependent on the module version
* Note: for Transit please refer to the BEMM (Body and Equipment Mounting Manual)
WARNING: The UIM can remain powered and operational when the vehicle is asleep if any of the UIM outputs are left in the active state, potentially depleting battery vehicle charge. It is the Upfitter’ s responsibility to design their UIM application logic, such that it performs to requirements
Page 4 of 27 Ford UIM Ford Motor Company
The following items will be required, in order to successfully create and implement a successful Upfitter application:
The UIM is pre-installed in the vehicle, or may be purchased separately. Replacement UIM’s are available through the dealership.
Blunt Cut Jumpers (Two 16-way harnesses). Included as part of the “Loose Kit” when a vehicle is ordered with a UIM. Replacement harnesses are available through the dealership.
UIM Project Editor installation README file UIM Project Editor software (Windows based .exe) UIM Project Editor User’s Manual UIM Owner’s Manual (this manual)
A standard Type B Universal Serial Bus (USB) 2.0 cable (not included)
Figure 1.1A
Figure 1.1B – USB 2.0 Cable (Type B)
Page 5 of 27 Ford UIM Ford Motor Company
2.0 Package Location
2.1 Refer to vehicle owner’s manual, BEMM or your local dealership
Page 6 of 27 Ford UIM Ford Motor Company
3.0 Input(s)/Output(s) Definition and Requirements
3.1 Input Switch Requirements Input numbers 1-9 of the UIM are configurable through the UIM Project Editor as either active low or active high inputs. The diagrams below illustrate the internal pull up and pull down configurations via the UIM Project Editor. Inputs 10 and 11 are Active Low only (non-user configurable) The UIM can support latching or momentary type switches. The switch types are configurable via the UIM Project Editor. See UIM Project Editor User’s Manual for more details.
Act
ive
Low
Act
ive
Hig
h
UIM Input Configuration
Generic UIM Input Circuit
Vbatt
Figure 3.1A – Generic UIM Input Circuit
Page 7 of 27 Ford UIM Ford Motor Company
Act
ive
Low
Act
ive
Hig
h
UIM Input Configuration
UIM Input Circuit Configured as Active High Input
External Upfitter Switch connected
to Power
Vbatt
Vbatt
Figure 3.1B – UIM Input Circuit Configured as Active High Input
Act
ive
Low
Act
ive
Hig
h
UIM Input Configuration
UIM Input Circuit Configured as Active Low Input
External Upfitter Switch connected
to Ground
Vbatt
Figure 3.1C –UIM Input Circuit Configured as Active Low Input
Page 8 of 27 Ford UIM Ford Motor Company
3.1.1 Electrical Requirements
The user supplied switches must withstand typical battery voltage and up to 32-volt jump start due to possible mis-wiring. All user supplied switches must be able to withstand a minimum current of 40mA. The switch contact’s closed resistance, including vehicle wiring, must be less than 50 Ω. The switch contact’s open resistance, including vehicle wiring, must be greater than 100 kΩ. Either switch type can be wired as an Active Low or Active High. Refer to diagrams below
Page 9 of 27 Ford UIM Ford Motor Company
3.2 Outputs
3.2.1 External Relay Configuration
3.2.1.1 High Side Driver Relay Configuration
For the high side (power side switched) outputs, the user supplied relays shall not require more than 500mA of current
to energize the coil. The user supplied relays shall have an operational range of 9V to 16V and with a nominal voltage
of 12V.
Upfitter Interface Module
High Current Device
Vbatt
HS
High-Side
Driver
Example
Figure 3.2.1.1 High Side Driver Relay Diagram
3.2.1.2 Low Side Driver Relay Configuration
Upfitter Interface Module High
Current Device
LS
Vbatt Vbatt
Low-Side
Driver
Example
Figure 3.2.1.2 Low Side Driver Relay Diagram
Page 10 of 27 Ford UIM Ford Motor Company
For the low side (ground side switched) outputs, the user supplied relays shall not require more than 320mA of current to energize the coil. The user supplied relays shall have an operational range of 9V to 16V and with a nominal voltage of 12V.
3.2.2 LED application
3.2.2.1 High Side Driver LED application
Figure 3.2.2.1A High Side Driver – Relay driven LED diagram
An isolation relay circuit is recommended to avoid LED flickering, as shown above.
A 1K current limiting resistance is required for the LED. This can be internal or external to the LED device.
Figure 3.2.2.1B High Side Driver – Module driven LED diagram
Although the HS drivers can directly drive LED's, it may sometimes result in a low intensity flickering while in the off
state, which may be noticeable in low light situations. Above is an LED example circuit which minimizes this flickering.
It is the Upfitter’ s responsibility to evaluate the effectiveness of this circuit in each application. If any flicker is
unacceptable, the LED should be driven using a relay in Figure 3.2.2.1A.
A 1K current limiting resistance is required for the LED. This can be internal or external to the LED device.
Page 11 of 27 Ford UIM Ford Motor Company
3.2.2.2 Low Side Driver LED Application
Figure 3.2.2.2A Low Side Driver – Relay driven LED diagram
An isolation relay circuit is recommended to avoid LED flickering, as shown above.
A 1K current limiting resistance is required for the LED. This can be internal or external to the LED device
Figure 3.2.2.2B Low Side Driver – Module driven LED diagram
Although the LS drivers can directly drive LED's, it may sometimes result in a low intensity flickering while in the off
state, which may be noticeable in low light situations. Above is an LED example circuit which minimizes this flickering.
It is the Upfitter’ s responsibility to evaluate the effectiveness of this circuit in each application. If any flicker is
unacceptable, the LED should be driven using a relay in Figure 3.2.2.2A.
A 1K current limiting resistance is required for the LED. This can be internal or external to the LED device
3.3 Application Examples
3.3.1 Coupling of Logic Blocks Using External Wiring
Each row of UIM logic is limited to 3 input variables and two logic functions. In many cases, the Upfitter may need to implement more logic than a single UIM logic row will support. Logic can be increased by looping UIM output pins back to UIM input pins with external wiring. When using this technique, high side outputs must be connected to inputs configured as active high inputs, and low side outputs must be connected to inputs configured as active low inputs.
Page 12 of 27 Ford UIM Ford Motor Company
Below is application example showing high side and low side outputs feeding back to further stages of logic using external wiring. The inputs connected to the outputs must be configured appropriately active high or active low inputs using the UIM Project Editor.
“Physical” wire
IN2
IN4
UIM Row Logic
HS1
HS2
LS1
IN1
IN3
IN5
Vbatt
High Current Device
Vbatt
Indicator
UIM Row Logic
Configurable Software Logic Block
CAN Signal-2
CAN Signal-2
UIM Row Logic
HS3
IN6 UIM Row Logic
Configured as Active High Input
Configured as Active Low Input
Configured as Active Low Input
Configured as Active High Input
Configured as Active High Input
CAN Signal-5
“Physical” wire
CAN Signal-3
CAN Signal-1
Configured as Active Low Input
CAN Signal-4
High Side Output
High Side Output
Low Side Output
High Side Output
Page 13 of 27 Ford UIM Ford Motor Company
3.3.2 Upfitter Application Example Using Input and Hall Effect Switches, and Relay Outputs:
Figure 3.3.2: System Input and Output Example
Page 14 of 27 Ford UIM Ford Motor Company
4.0 Connector Pin Out and Wiring
4.1 Connectors - The UIM has 3 Molex Connectors
Figure 4.1 (Module Side Face View)
4.1.1 8-way Vehicle Connector (Black). Key Way A. Molex Part# 34728-0080.
Female mating connector terminal type: Tyco Electronics GEN-Y. Part# 1456574-X. The 8-way connection is made by the Ford assembly plant when the vehicle is equipped with the UIM.
C1- Inputs (Upfitter Switch
Connections, and/or private
CAN bus)
C2- Outputs
(Upfitter
Connections)
C3- Vehicle Pwr,
Gnd. Ford Plant
Connection USB connection
Page 15 of 27 Ford UIM Ford Motor Company
Figure 4.1.1A - Module Side Figure 4.1.1B - Harness Connector Side Front View
Table 4.1.1
Molex (Female) Part# 34728-0080
Circuit Definition Wire Color American Wire Gauge (AWG)
C3-1 Power (B+) Blue/Red (BU/RD) 18
C3-2 DO NOT CONNECT --------------------------- -----------------------
C3-3 DO NOT CONNECT --------------------------- -----------------------
C3-4 Ground Black/Grey (BK/GY) 18
C3-5 DO NOT CONNECT --------------------------- -----------------------
C3-6 CAN1+ White/Blue (WH/BU) 20
C3-7 CAN1- White (WH) 20
C3-8 DO NOT CONNECT --------------------------- -----------------------
Notes: 1) Pins defined as “DO NOT CONNECT” shall not be used under any circumstances, as it may cause damage to
the module and/or vehicle, and equipment.
2) Low side drivers supply a ground to the application circuit when active.
High side drivers supply power to the application circuit when active.
Page 16 of 27 Ford UIM Ford Motor Company
4.1.2 Wiring Harness – 16-way Output Connector (Black). Key Way A. Molex Part# 34728-0160.
Female mating connector terminal type: Tyco Electronics GEN-Y. Part# 1456574-X.
Figure 4.1.2A - Module Side Figure 4.1.2B - Harness Connector Side Front View
Table 4.1.2
Molex (Female) Part# 34728-0160
Circuit Definition Wire Color American Wire Gauge (AWG)
C2-1 High Side Driver 7 Violet/Green (VT/GN) 18
C2-2 High Side Driver 8 Blue/Orange (BU/OG) 18
C2-3 DO NOT CONNECT --------------------------- -----------------------
C2-4 Low Side Driver 6 Violet/Orange (VT/OG) 18
C2-5 Low Side Driver 4 Violet/Grey (VT/GY) 18
C2-6 Low Side Driver 2 Yellow/Violet (YE/VT) 18
C2-7 High Side Driver 2 Brown/Green (BN/GN) 18
C2-8 High Side Driver 4 White/Orange (WH/OG) 18
C2-9 High Side Driver 6 White/Green (WH/GN) 18
C2-10 High Side Driver 5 Brown/Violet (BN/VT) 18
C2-11 Low Side Driver 7 Brown/Yellow (BN/YE) 18
C2-12 Low Side Driver 5 White/Violet (WH/VT) 18
C2-13 Low Side Driver 3 Grey/Brown (GY/BN) 18
C2-14 Low Side Driver 1 Yellow/Green (YE/GN) 18
C2-15 High Side Driver 3 White/Brown (WH/BN) 18
C2-16 High Side Driver 1 Blue/Brown (BU/BN) 18
Note: Pins defined as “DO NOT CONNECT” shall not be used under any circumstances, as it may cause damage to the module and/or vehicle, and equipment.
Page 17 of 27 Ford UIM Ford Motor Company
4.1.3 Wiring Harness – 16-way Input Connector (Grey). Key Way B. Molex Part#34728-0161.
Female mating connector terminal type: Tyco Electronics GEN-Y. Part# 1456574-X.
Figure 4.1.3A - Module Side Figure 4.1.3B - Harness Connector Side Front View
Table 4.1.3
Molex (Female) Part# 34728-0161
Circuit Definition Wire Color American Wire Gauge (AWG)
C1-1 Digital Input 1 Blue (BU) 18
C1-2 Digital Input 2 Grey (GY) 18
C1-3 Digital Input 3 Grey/Yellow (GY/YE) 18
C1-4 Digital Input 4 Violet/White (VT/WH) 18
C1-5 Digital Input 5 White/Green (WH/GN) 18
C1-6 Digital Input 6 Gray/Violet (GY/VT) 18
C1-7 Digital Input 7 Violet/Brown (VT/BN) 18
C1-8 Digital Input 8 Gray/Blue (GY/BU) 18
C1-9 Digital Input 9 Blue/Gray (BU/GY) 18
C1-10 Digital Input 10 Green/Orange (GN/OG) 18
C1-11 UPFITTERS CUSTOMER ACCESS CAN BUS HIGH SPEED HIGH
Green/Blue (GN/BU) 18
C1-12 UPFITTERS CUSTOMER ACCESS CAN BUS HIGH SPEED LOW
Grey/Violet (GY/VT) 18
C1-13 Hall Feed (Power) Brown/White (BN/WH) 18
C1-14 DO NOT CONNECT --------------------------- -----------------------
C1-15 Hall Input Grey/Yellow (GY/YE) 18
C1-16 Hall Return (Ground) Brown/Violet (BN/VT) 18
Page 18 of 27 Ford UIM Ford Motor Company
Note: Pins defined as “DO NOT CONNECT” shall not be used under any circumstances, as it may cause damage to the module and/or vehicle, and equipment. 4.2 Wiring Harness (Part# JK2T 14A303 C* Ford provides the wiring harnesses (C2 and C3) crimped on the two 16-way connectors as one complete set with the part# mentioned above. These harnesses are blunt cut wires allowing the Upfitter to connect to automotive grade external relays on the C2 harness and switches on the C1 harness.
Figure 4.2
Page 19 of 27 Ford UIM Ford Motor Company
5.0 General Electrical Specifications
5.1 The UIM I/O Specifications
5.1.1 Inputs
The UIM will support the following 11 inputs.
Table 5.1.1: Hardwired Electrical Characteristics for Switch Inputs Digital Hall Input:
The UIM supports a digital hall-effect switch on input 10 and 11 only (active or inactive states only). This UIM input does not support using analog hall effect sensors. The UIM supports 3-wire hall-effect switches using the Feed (Power), Input, and Return (Ground) connections. The UIM supplies power to the hall switch in the range of 9V to 16V relative to UIM ground. The hall switch feed is capable of supplying a max current of 100mA.
Functional Description
Configuration of Internal Module Pull Up or Pull Down resistor
Input Min Voltage (V)
Input Nominal Voltage (V)
Input Max Voltage (V)
Active State
Inactive State
Digital Input (1-9) configured as Active Low (continuity to ground)
Internal resistor configured as Pull Up
9 13.5 16 GND (ON)
OPEN (OFF)
Digital Input (1-9) configured as Active High (continuity to power)
Internal resistor configured as Pull Down
9 13.5 16 VBATT (ON)
OPEN/ GND (OFF)
Input #10 and 11 – Non configurable Active Low Digital Input OR 3 wire Digital Hall Device.
Internal resistor defined as Pull Up only
9 13.5 16 GND (ON)
OPEN (OFF)
Page 20 of 27 Ford UIM Ford Motor Company
5.1.2 Upfitter Interface Module Output Electrical Requirements:
The UIM provides 7 low side outputs and 8 high side outputs. The table below describes the electrical requirements for these outputs.
Table 5.1.2: Hardwired Outputs
5.1.3 Upfitter Interface Module Power Requirements
The factory wiring provides direct battery feed to the UIM. The table below defines the UIM’s power consumption.
Table 5.1.3: Total Module Power Consumption Note: The factory wiring provides power to the UIM at all times.
5.1.4 Upfitter Interface Module Ground
Using the standard vehicle wiring harness, the UIM is electrically connected to vehicle chassis ground.
5.1.5 Standard USB 2.0 Interface.
The customer will program the UIM on a Windows based PC via the USB 2.0 port. During programming, the UIM can either be powered by the vehicle’s battery, or powered through the PC’s USB connection, (e.g. programming UIM on benchtop).
5.1.6 Environmental Requirements
The UIM is rated to operate between -40 to 85 degrees C.
Functional Description
Min Voltage (V)
Max Voltage (V)
Min Current (A)
Max Current (A)
Low Side Drivers (1-7) Ground N/A 0.170 0.320
High Side Drivers (1-8) N/A Power (B+)
0.170 0.500
Functional Description
Min Voltage (V)
Max Voltage (V)
Min Current (A)
Max Current (A)
Power (B+ ) 9 16 0 7.0
Page 21 of 27 Ford UIM Ford Motor Company
6.0 Trouble Shooting
Description of Operation - FET Protection Strategy:
The Upfitter Interface Module utilizes a Field Effect Transistor (FET) protective circuit strategy to protect the low and high side driver output circuits. Output loads (current levels) are monitored for excessive current (which is typically caused by a short circuit to ground) and are shut down (turns off the voltage or ground provided by the module) when a fault is detected.
A short to battery voltage occurring on either a low or high side driver output circuit may also result in a temporarily loss of operation in the output circuit (no voltage or ground will be applied to the output circuit) to protect the module against a potential over temperature condition.
A Field Effect Transistor (FET) is a type of transistor that the module uses to control and monitor current flow on module output circuits. The Field Effect Transistor (FET) protection strategy prevents damage from occurring to the module.
Whenever a FET is turned off because of a fault condition a DTC is set in the module which corresponds to the specific fault observed. The module resets the Field Effect Transistor (FET) protection and allows the circuit to function when the fault is corrected or the ignition is cycled off and then back on. The ignition should always be cycled from off to on after a fault is corrected to ensure that FET protection is reset.
Module DTC List
DTC Description
Fault Trigger Condition
Module DTCs
U1000:00 (solid state driver protection active) This DTC indicates that a FET driver (either low or high side driver) has been temporarily disabled as the result of a fault condition. The FET driver will be disabled until the concern is corrected and this DTC is cleared by a service scan tool.
U0140:01 (lost communication with the body control module)
This DTC sets when the Up Fitter Module detects a loss of communication with the BCM – Body Control Module.
U3000:49 (internal electronic failure) This DTC sets when the low/high FET driver has been permanently disabled as the result of an ongoing fault condition. Module replacement is required to resolve this fault condition.
High Side Driver Fault DTCs
B14F0:11 (high side driver 1 short to ground) This DTC sets when the Up Fitter Module detects a short to ground on pin 16 – Connector C2 when the circuit is commanded on by an input to the module. The FET driver for this circuit is disabled when the fault is present.
B14F0:12 (high side driver 1 short to battery) This DTC sets when the Up Fitter Module detects a short to battery on pin 16 – Connector C2 when the circuit is commanded on by an input to the module. The FET driver for this circuit is disabled when the fault is present.
Page 22 of 27 Ford UIM Ford Motor Company
B14F0:13 (high side driver 1 open circuit) This DTC sets when the Up Fitter Module detects an open and or current value of less than 10mA on pin 16 – Connector C2 when the circuit is commanded on by an input to the module.
B14F1:11 (high side driver 2 short to ground) This DTC sets when the Up Fitter Module detects a short to ground on pin 7 – Connector C2 when the circuit is commanded on by an input to the module. The FET driver for this circuit is disabled when the fault is present.
B14F1:12 (high side driver 2 short to battery) This DTC sets when the Up Fitter Module detects a short to battery on pin 7 – Connector C2 when the circuit is commanded on by the module. The FET driver for this circuit is disabled when the fault is present.
B14F1:13 (high side driver 2 open circuit This DTC sets when the Up Fitter Module detects an open and or current value of less than 10mA on pin 7 – Connector C2 when the circuit is commanded on by an input to the module.
B14F2:11 (high side driver 3 short to ground) This DTC sets when the Up Fitter Module detects a short to ground on pin 15 – Connector C2 when the circuit is commanded on by an input to the module. The FET driver for this circuit is disabled when the fault is present.
B14F2:12 (high side driver 3 short to battery) This DTC sets when the Up Fitter Module detects a short to battery on pin 15 – Connector C2 when the circuit is commanded on by the module. The FET driver for this circuit is disabled when the fault is present.
B14F2:13 (high side driver 3 open circuit) This DTC sets when the Up Fitter Module detects an open and or current value of less than 10mA on pin 15 – Connector C2 when the circuit is commanded on by an input to the module.
B14F3:11 (high side driver 4 short to ground)
This DTC sets when the Up Fitter Module detects a short to ground on pin 8 – Connector C2 when the circuit is commanded on by an input to the module. The FET driver for this circuit is disabled when the fault is present.
B14F3:12 (high side driver 4 short to battery) This DTC sets when the Up Fitter Module detects a short to battery on pin 8 – Connector C2 when the circuit is commanded on by the module. The FET driver for this circuit is disabled when the fault is present.
B14F3:13 (high side driver 4 open circuit) This DTC sets when the Up Fitter Module detects an open and or current value of less than 10mA on pin 8 – Connector C2 when the circuit is commanded on by an input to the module.
B14F4:11 (high side driver 5 short to ground) This DTC sets when the Up Fitter Module detects a short to ground on pin 10 – Connector C2 when the circuit is commanded on by an input to the module. The FET driver for this circuit is disabled when the fault .
DTC Description
Fault Trigger Condition
B14F4:12 (high side driver 5 short to battery) This DTC sets when the Up Fitter Module detects a short to battery on pin 10 – Connector C2 when the
Page 23 of 27 Ford UIM Ford Motor Company
circuit is commanded on by the module. The FET driver for this circuit is disabled when the fault is present.
B14F4:13 (high side driver 5 open circuit) This DTC sets when the Up Fitter Module detects an open and or current value of less than 10mA on pin 10 – Connector C2 when the circuit is commanded on by an input to the module.
B14F5:11 (high side driver 6 short to ground) This DTC sets when the Up Fitter Module detects a short to ground on pin 9 – Connector C2 when the circuit is commanded on by an input to the module. The FET driver for this circuit is disabled when the fault is present.
B14F5:12 (high side driver 6 short to battery) This DTC sets when the Up Fitter Module detects a short to battery on pin 9 – Connector C2 when the circuit is commanded on by the module. The FET driver for this circuit is disabled when the fault is present.
B14F5:13 (high side driver 6 open circuit) This DTC sets when the Up Fitter Module detects an open and or current value of less than 10mA on pin 9 – Connector C2 when the circuit is commanded on by an input to the module
B14F6:11 (high side driver 7 short to ground) This DTC sets when the Up Fitter Module detects a short to ground on pin 1 – Connector C2 when the circuit is commanded on by an input to the module. The FET driver for this circuit is disabled when the fault is present.
B14F6:12 (high side driver 7 short to battery) This DTC sets when the Up Fitter Module detects a short to battery on pin 1 – Connector C2 when the circuit is commanded on by the module. The FET driver for this circuit is disabled when the fault is present.
B14F6:13 (high side driver 7 open circuit) This DTC or current value of less than 10mA on pin 1 – Connector C2 when sets when the Up Fitter Module detects an open and the circuit is commanded on by an input to the module.
B14F7:11 (high side driver 8 short to ground) This DTC sets when the Up Fitter Module detects a short to ground on pin 2 – Connector C2 when the circuit is commanded on by an input to the module. The FET driver for this circuit is disabled when the fault is present.
B14F7:12 (high side driver 8 short to battery) This DTC sets when the Up Fitter Module detects a short to battery on pin 2 – Connector C2 when the circuit is commanded on by the module. The FET driver for this circuit is disabled when the fault is present.
B14F7:13 (high side driver 8 open circuit) This DTC sets when the Up Fitter Module detects an open and or current value of less than 10mA on pin 2 – Connector C2 when the circuit is commanded on by an input to the module.
Low Side Driver Fault DTCs
B14F8:11 (low side driver 1 short to ground) This DTC sets when the Up Fitter Module detects a short to ground on pin 14 – Connector C2 when the circuit is commanded on by an input to the module. The FET driver for this circuit is disabled when the fault is present.
Page 24 of 27 Ford UIM Ford Motor Company
B14F8:12 (low side driver 1 short to battery)
This DTC sets when the Up Fitter Module detects a short to battery on pin 14 – Connector C2 when the circuit is commanded on by the module. The FET driver for this circuit is disabled when the fault is present.
F14F8:13 (low side driver 1 open circuit) This DTC sets when the Up Fitter Module detects an open and or current value of less than 10mA on pin 14 – Connector C2 when the circuit is commanded on by an input to the module.
B14F9:11 (low side driver 2 short to ground) This DTC sets when the Up Fitter Module detects a short to ground on pin 6 – Connector C2 when the circuit is commanded on by an input to the module. The FET driver for this circuit is disabled when the fault is present.
B14F9:12 (low side driver 2 short to battery) This DTC sets when the Up Fitter Module detects a short to battery on pin 6 – Connector C2 when the circuit is commanded on by the module. The FET driver for this circuit is disabled when the fault is present.
B14F9:13 (low side driver 2 open circuit) This DTC sets when the Up Fitter Module detects an open and or current value of less than 10mA on pin 6 – Connector C2 when the circuit is commanded on by an input to the module.
B14FA:11 (low side driver 3 short to ground) This DTC sets when the Up Fitter Module detects a short to ground on pin 13 – Connector C2 when the circuit is commanded on by an input to the module. The FET driver for this circuit is disabled when the fault is present.
B14FA:12 (low side driver 3 short to battery) This DTC sets when the Up Fitter Module detects a short to battery on pin 13 – Connector C2 when the circuit is commanded on by the module. The FET driver for this circuit is disabled when the fault is present.
B14FA:13 (low side driver 3 open circuit) This DTC sets when the Up Fitter Module detects an open and or current value of less than 10mA on pin 13 – Connector C2 when the circuit is commanded on by an input to the module.
B14FB:11 (low side driver 4 short to ground)
This DTC sets when the Up Fitter Module detects a short to ground on pin 5 – Connector C2 when the circuit is commanded on by an input to the module. The FET driver for this circuit is disabled when the fault
DTC Description
Fault Trigger Condition
B14FB:12 (low side driver 4 short to power) This DTC set when the Up Fitter Module detects a short to battery on pin 5 – Connector C2 when the circuit is commanded on by the module. The FET driver for this circuit is disabled when the fault is present.
B14FB:13 (low side driver 4 open circuit) This DTC sets when the Up Fitter Module detects an open and or current value of less than 10mA on pin 12 – Connector C2 when the circuit is commanded on by an input to the module.
Page 25 of 27 Ford UIM Ford Motor Company
B14FC:11 (low side driver 5 short to ground) This DTC sets when the Up Fitter Module detects a short to ground on pin 12 – Connector C2 when the circuit is commanded on by an input to the module. The FET driver for this circuit is disabled when the fault is present.
B14FC:12 (low side driver 5 short to battery) This DTC sets when the Up Fitter Module detects a short to battery on pin 12 – Connector C2 when the circuit is commanded on by the module. The FET driver for this circuit is disabled when the fault is present.
B14FC:13 (low side driver 5 open circuit) This DTC sets when the Up Fitter Module detects an open and or current value of less than 10mA on pin 12 – Connector C2 when the circuit is commanded on by an input to the module.
B14FE:11 (low side driver 6 short to ground) This DTC sets when the Up Fitter Module detects a short to ground on pin 4 – Connector C2 when the circuit is commanded on by an input to the module. The FET driver for this circuit is disabled when the fault is present.
B14FE:12 (low side driver 6 short to ground) This DTC sets when the Up Fitter Module detects a short to battery on pin 4 – Connector C2 when the circuit is commanded on by the module. The FET driver for this circuit is disabled when the fault is present.
B14FE:13 (low side driver 6 open circuit) This DTC sets when the Up Fitter Module detects an open and or current value of less than 10mA on pin 4 – Connector C2 when the circuit is commanded on by an input to the module.
B14FF:11 (high side driver 7 short to ground) This DTC sets when the Up Fitter Module detects a short to ground on pin 11 – Connector C2 when the circuit is commanded on by an input to the module. The FET driver for this circuit is disabled when the fault is present.
B14FF:12 (high side driver 7 short to ground) This DTC sets when the Up Fitter Module detects a short to battery on pin 11 – Connector C2 when the circuit is commanded on by the module. The FET driver for this circuit is disabled when the fault is present.
B14FF:13 (high side driver 7 short to ground) This DTC sets when the Up Fitter Module detects an open and or current value of less than 10mA on pin 11 – Connector C2 when the circuit is commanded on by an input to the module.
Page 26 of 27 Ford UIM Ford Motor Company
7.0 Appendix
7.1 Appendix A – Definitions USB - Universal Serial Bus- A communication link for personal computer programing of the UIM via the UIM Project Editor. CAN interface - The UIM can be configured to monitor CAN signals in customer programmable logic and perform specialized vehicle functions via CAN. Customer Outputs - The UIM contains dedicated high side and low drivers. The states of the outputs are controlled by the customer programmable logic. Customer Configurable Inputs - The UIM individual switch inputs can be configured as either switch to ground (active low) or switch to power (active high). Diagnostics - The UIM supports Diagnostic Trouble Codes (DTCs) according to the ISO 14229 standard. These DTC’s are defined in section 6 of this manual and also the UIM Project Editor User Manual.
Page 27 of 27 Ford UIM Ford Motor Company
Revision Record
Version Level
Revision Date
Change Description
1.0 Initial Release.
Recommended