View
215
Download
0
Category
Preview:
Citation preview
Features:
• Recessedlayinceilingmounting(only115mmvoiddepthrequired)
• Designedfor600x600mmnarrow/wide(15/25mm)‘T’gridsystems
• Highperformanceenergyefficientsurface-mount-device(SMD)LEDs
• ChoiceofthreeLEDlightoutputs:-2x12WLED-4000K-3500lm-2x17WLED-4000K-4720lm-2x22WLED-4000K-6780lm
• CRI>80
• Average50,000hrsLEDlife–maintenancefree
• Directlightdistribution
Options:
• Integral3hrmaintainedemergency
• Dimmingversionsavailable:-DALI(digital)
• IntegratedRemoteIntelligentControl(RIC®)
• IntegratedManualIntelligentControl(MIC®)
• 3000K(warmwhite)LEDcolourtemperatureavailable-onspecialrequest
• Plug&Connect
Accessories:
• Surfacemountingframe
Material:
• Body:Zintecsteel
• Lens:polycarbonate
Finish:
• Body:powdercoated
• Lens:cloud
Colour:01 White
Spares:
AllcomponentsareavailablefromSteonLighting’sUKmanufacturingfacility.
TheseluminairesaredesignedtocomplywithBSEN60598–1
FLIGHTWAVE
Options & Accessories
Technical & Photometrics
115
597
597
FLIGHT WAVE LED 2X17W, 4000K – 4720lm
180° 150°150°
120°120°
90°90°
0° 30°30°
60°60°
cd / 1000 lmC0 / C180 C90 / C270
50
100
150
200
250
Flight Wave Ordering Code
2x12WLED-4000K-3500lm 45-181-000-401
2x17WLED-4000K-4720lm 45-182-000-401
2x22WLED-4000K-6780lm 45-183-000-401
Options Add to Ordering Code
Emergency(3hour) E3-
DALI(digital)dimming /DD
MIC1 /MIC1
MIC2 /MIC2
MIC3 /MIC3
RIC /RIC
Plug&Connect /PC
Accessories Ordering Code
Surfacemountingframe A45-01-01-01
Plug&Connectforeaseofinstallation
Mountingframeforplasterboardceilings
steon.com
REC
ESSE
D M
OD
ULA
RS
RIC®
TheRemoteIntelligentControl(RIC®)systemisanadvancedtechnologycontrolsystemavailableonmanyofourluminaries.TheluminaireshaveanintegratedPIRavailablewithachoiceofdetectionangles,thisintegrationnegatesadditionalwiringtoremotesensorsandallowsforextremelyversatileinstallations,especiallywhereRICluminairesareusedinconjunctionwithslavedDALIluminaires.
OperatingparametersarehighlycustomisableaseachRICluminaire(orluminairecluster)isaddressableusinganinfra-redprogramminghandset.Thisallowstheclienttofinetuneoneorallofthesystemsvariedfeaturestotheiruniqueapplication-featuresincluding:presencedetection,luxlevelsensing,dynamicdaylightcompensation,zoning&scenesetting.
Capitalisingupontheabovecorefeaturesthismarketleadingsystemensuresthecorrectamountoflightasandwhenrequired,inturndeliveringsignificantenergysavings.
TheRICsystemiscompatiblewithPlug&Connectrapidinstallationoptions.
Prolongedabsenceinclusterareas-luminairesremainoff
EmergencyprovisionsintegratedintoRICclusters
Presencedetectionandtimedelaysmanagecorridorlightingrequirements(forfurtherdetailsseepresencedetectionoverleaf)
Occupationdetectedwithnodaylight-Luminairesmaintain100%output
Occupationdetectedwithlimiteddaylight-luminairesmaintainhigheroutput,constantluxlevelanduniformity
Occupationdetectedwithhighlevelsoflightingress-luminairesdimdynamicallytomaintainconstantluxlevelanduniformity
LuminairewithintegratedRICsensor
Luminaireoutputdimmed<10%
Luminaireoutputdimmed10-75%
Luminaireoutputdimmed100-75%
Nopresence-luminaireoff
Luminairehasintegral3houremergency
Master/slaveconnection
steon.com
RIC®
Apassiveinfra-red(PIR)sensorisusedtodetectmovementinagivenspace.UpondetectionofpresencetheRIC®systemwillturntheluminaire(s)on.WithintheRIC®systemtheluminaire(s)canbeconfiguredtodimorturnofffollowingapre-determinedperiodofabsence.
Nooccupancydetectedthereforeluminairesremainoffordimmedtopre-setoutput.
Mediumdistribution(MD)2.8metreceiling
Widedistribution(WD)2.8metreceiling
Occupancydetected-luminairesilluminatecorridortoapre-setluxlevel(outputadjustedinaccordancewithdaylightingress).
TheremotecontrolcaneasilyprogramallRIC®sensors.Thisfeaturecanbesavedandduplicatedquicklyandeasilytotheremainingsensorsrequiringthesameluxlevels.
ThecompactinfraredhandsetcanbeusedforthebasicprogrammingofluminairesthatincorporateRICcontrols.
TheRIC®sensorisintegratedwithintheluminaire.Thisenablestheluminairetoworkineitheramasteroraslave(controlledbymaster).
TheRIC®sensorissuitableforcontrollingindependantormultipleslaveluminaires.
Followingprolongedabsence,theluminairescanbeeither:•Switchedoff•Dimmedtoapre-setlevel•Dimmedforapre-setperiodbeforeswitchingoff
5m
2.8m
7m
2.8m
Sensors Specification
Product Images
Presence Detection
WhenspecifyingtheRIC®system,refertotherelevantluminairedatasheetandorderasfollows:
1.FormasterRICluminairessuffix:/RIC-MD(mediumdistribution)or/RIC-WD(widedistribution)
2.Forslaveluminairessuffix:/DD(DALI)
E.g.AircorecessedmodularwithRICmasterandthreeslaves:
1Quantity:45-131-001-401/RIC
3Quantity:45-131-001-401/DD
steon.com
MIC®
ONDIM DIM
Absence – luminaires areon at a courtesy preset dimmed level. Approximately 20% output and 1/3 total power.
Occupancy detected –luminaires illuminate at full output.
Absence – after a preset time of absence, luminaires return to the courtesy preset dimmed level.
MIC1
MIC2
MIC3
Aversatileandcost-effectiveOFF–ON–OFFenergysavingcontrolunit.
OffersallthebenefitsoftheMIC1butwithaDIM–ON–DIMfunction.MIC2isanidealcontrolforreducingenergyconsumptionswhilststillprovidingsomelevelofilluminationforextrasafety.
MIC3isthemostflexibleenergysavingmanualcontrolwithanOFF-ON-DIM-OFFfunction,permittingoptimallightmanagement.
ON
ON
ON
OFF
DIM
OFF
OFF
DIM
DIM OFF
Absence: luminaires areswitched off.
Absence: luminaires areon at a courtesy preset dimmed level. Approximately 20% output and 1/3 total power.
Absence: luminaires areswitched off.
Occupancy detected:luminaires illuminate at full output unless there is sufficient daylight and the lux level setting overides it.
Occupancy detected:luminaires illuminate at full output.
Occupancy detected:luminaires illuminate at full output.
Absence: after a preset time, luminaires switch off completely.
Absence: after a preset time of absence, luminaires return to the courtesy preset dimmed level.
Absence: after a preset time of absence, luminaires return to the courtesy preset dimmed level.
After continued absence over a preset time, luminaires switch off completely. If required, the ‘off’ function can be disabled to operate as a MIC 2.
TheManualIntelligentControl(MIC®)systemfeaturesarangeofadvancedsensortechnologycontrolsofferingtheultimateinenergysavingandcarbonreduction.SignificantenergysavingscanbeachievedwithaMICsystemthatdynamicallymanagesluminairepoweraccordingtotheinstantaneouslightingrequirement.Itensuresthattherightleveloflightappearsattherightplaceonlywhenrequired,thuspreventingunnecessaryenergyconsumptionandreducingmaintenancecosts.TheMICsystemhasbeeninstalledinover3000BTtelephoneexchangeswithconfirmedenergysavingsinexcessof70%.
TherearethreetypesofManualIntelligentControl:MIC1,MIC2andMIC3,availableasamaster(sensorincorporated)oraslave(controlledbymaster),tosuitdifferentrequirementsandbudgets.
steon.com
MIC®
Setting 1 =2metres Setting 2 = 5 metres Setting 3 =10metres
0
3.5
10 08 6 4 2 2 4 6 8 10
Detection area (metres)
Mou
ntin
g H
eigh
t (m
etre
s)
Sett ing 1 = 1 metre S ett ing 2 = 3 me tres S ett ing 3 = 6 me tres
0
8
10 08 6 4 2 2 4 6 8 10
Detection area (metres)
Mou
ntin
g H
eigh
t (m
etre
s)
Option OneThemastersareallworkingindependentlyformaximumenergyefficiencytocreateacascadeeffect.Thisisidealforaretrofitinstallation.
Option TwoThemasterisworkinginconjunctionwithaslavetoilluminateaspecificzone.Themasterwillcontroltheslaves.
Option ThreeThemastersandtheslavesareworkinginconjunctiontoilluminatealargerarea.
Option FourThemastersareworkingtogetherforincreasedefficiencyandmaximumsensitivityinazonedarea.
Option FiveThemastersareworkingtogetherforincreasedefficiencyandmaximumsensitivityinalargerarea.
MIC1&2 MIC3
Detection Area
Typical Installation Options
MIC Operating Functions and Features MIC 1 MIC 2 MIC 3
Operatingfunction DIPSwitch DIPSwitch DIPSwitch
Luxleveladjustment 0–2000lux N/A 0–2000lux
Timeadjustmenttocourtesypresetdimmedlevel N/A 5–30mins 5–30mins
Timeadjustmenttoswitchoffcompletely 5–30mins N/A 10–30mins
Sensitivity(range)adjustment 2–10metres 2–10metres 1–6metres
Dimminglevel(iLiteballast/driver) N/A 10/25/50% 10/25/50%
Detectionangle 360° 360° 360°
Sensormaximumload(inductive) 600W 600W 600W
steon.com
PLUG&CONNECT Plug&Connect(P&C)isalinkableconnectionsystemwherebylightingcanbeinstalledrapidlywithminimaldisruption.
Traditionalinstallationsareoftenlabourintensive,inflexibleandrequirecostlyexpertise.TheP&Csystemcanquicklyinstallalightingschemewithouttheneedforanelectriciansimplybyconnectingtheluminairestogetherwithaplugandsockettypesystem.
Allcomponentsfeatureindustrystandardcodingtoensurecorrectpolarityisguaranteed.Thisalsoaccomodatesforfutureadaptations.P&CisidealwhereemergencyorDALIsystemsareincorporatedwithlightingcontrols.
WhereourdatasheetsofferPlug&Connect(/PC)theluminairewillbesuppliedwiththisfacility.Thisistobeusedinconjunctionwiththetypicalcomponentsshownbelow.P&Cisavailablein1mmor1.5mmLSFcablewith3,4,5and6poleoptions.Thesecablescanbesuppliedtobespokelengths.
Wewouldrecommendthattheprojectisdiscussedwithourtechnicaldepartmentandafullinstallationdesigncanbeoffered.Thediagrambelowindicatesatypicaldesign.
P&Cpanelmountingsocketfittedtoluminaire.
T-plugforsnappingintoluminairepanelmountedsocket,forbothmaleandfemaleplugs.
P&Cmarshallingbox,upto6polelatchingconnections.8or10wayluminaireoutputs,suitableforsingleordualPIRdetection.Maximumtotalload12A.
MaleandfemaleplugsfittedintoT-plug.
Starterfemaleplugwithultrasonicallyweldedcontactsavailableinallcableconfigurationsandsizes.
PCMB
PC
PC
PCPC
PCPC
PC
PCMBT
MalePlug
FemalePlug
T-plug
Marshallingbox
LuminairewithP&Ccompatibility
T
steon.com
Recommended