608 State St. South Kirkland, WA 98033
www.faira.com
hello@faira.com +1.800.571.FAIR
FAIRA TRANSPARENCY REPORTS
51 Point View Ave, Brinnon, WA 98320
June 5th, 2017 Thank you for your interest in this Faira Certified home. We have coordinated the efforts of certified and licensed inspection and title professionals to create the Faira Transparency Reports for this home. The Faira Transparency Reports are a detailed portfolio of information that is prepared on behalf of buyers in preparation for making an informed offer on the property.
You may view more detailed information for this home and can make an offer at
http://www.faira.com/listings/11114 All of the information in the Faira Transparency Reports was gathered and compiled without any bias or influence from the seller(s). In fact, these reports are materially identical had you as the buyer(s) ordered the same professionals to perform the evaluations on the same date. Nevertheless, Faira takes no obligation of the reports being complete or accurate. The buyers are recommended to conduct their own due-diligence to their satisfaction. Please contact us if you have any questions or would like more information. We’re happy you’ve chosen a Faira Certified home and look forward to the opportunity of working with you! The Faira Team
Inspection Report for Mrs. Vicky HoudekProperty Address: 51 Point View Ave, Brinnon, Washington 98320
NW WASHINGTON HOME INSPECTIONS LLC
Carl Liberman WA License # 1758 Bainbridge Island, WA
Table of Contents
Cover Page.................................................................1
Table of Contents ........................................................2
Intro Page ...................................................................3
Significant Issues ........................................................5
Repair & Maintenance Summary ................................6
Complete Wood Destroying Organism InspectionReport .......................................................................10
1 Roof .......................................................................12
2 Attic ........................................................................18
3 Exterior...................................................................20
4 Wall Exteriors.........................................................27
5 Structure ................................................................28
6 Electrical ................................................................29
7 Interior....................................................................32
8 Plumbing ................................................................35
9 Heating...................................................................39
10 Bathrooms............................................................42
11 Kitchen and Built-in Appliances............................43
12 Laundry Room .....................................................46
Invoice.......................................................................48
NW WASHINGTON HOME INSPECTIONS LLC Houdek
51 Point View Ave Page 2 of 48
Date: 6/2/2017 Time: 09:00 AM Report ID: 170602A / ICN10208AR001
Property:51 Point View AveBrinnon Washington 98320
Customer:Mrs. Vicky Houdek
Real Estate Professional:Chris EllisFaira.com
Dear Mrs. Houdek,
Thank you for choosing NW WASHINGTON HOME INSPECTIONS LLC for your home inspection needs. I greatlyappreciate the importance of this inspection and have done my utmost to provide you with an organized,sufficiently-detailed, and easy-to-read report.
Two summary reports are provided at the beginning of the report highlighting the most significant findings. TheSignificant Issues Summary includes the most serious issues identified during the inspection. The Repair &Maintenance Summary includes the remainder of those potentially near-term actionable items for you to considerbased on the inspection. The results of your Structural Pest Inspection are also summarized in the Complete WoodDestroying Organism Inspection Report, also included at the beginning of the Home Inspection Report.
The body of the report is organized by system: Roofing, Structure, Electrical, etc. I have included pictures whenpossible. Please review the entire report as there is additional information presented in the body of the report thatmay not be found in the summaries.
If you have any questions regarding your inspection, please feel free to contact me directly at 206.841.9532 or emailme at carl@nwwahomeinspections.com. I look forward to providing future home inspection needs to you, yourfriends, and family.
Warm Regards,
Carl Liberman
Significant Issues ( ) = Items or discoveries indicate that these systems or components may cost significant moneyto correct now or in the near future, or items that require immediate attention to prevent additional damage or eliminatesafety hazards. Further investigation by a specialist and/or subsequent observation may be required.
Repair & Maintenance ( ) = Items or discoveries indicate that these systems or components do not function asintended and/or maintenance is required in the near term. Further investigation by a specialist and/or subsequentobservation may be required.
Wood Destroying Organisms ( ) = Items or discoveries that indicate the presence of wood destroying organisms orconditions conducive to wood destroying organisms. Conducive conditions include but are not limited to, inadequateclearances, earth/wood contact, cellulose debris, inadequate ventilation, and excessive moisture.
Standard Limitations: Home inspectors are not required to report on the following: Life expectancy of any component or system; The causes ofthe need for a repair; The methods, materials, and costs of corrections; The suitability of the property for any specialized use; Compliance ornon-compliance with codes, ordinances, statutes, regulatory requirements or restrictions; The market value of the property or its marketability;The advisability or inadvisability of purchase of the property; Any component or system that was not observed; The presence or absence ofpests such as wood damaging organisms, rodents, or insects; or Cosmetic items, underground items, or items not permanently installed. Homeinspectors are not required to: Offer warranties or guarantees of any kind; Calculate the strength, adequacy, or efficiency of any system orcomponent; Enter any area or perform any procedure that may damage the property or its components or be dangerous to the home inspectoror other persons; Operate any system or component that is shut down or otherwise inoperable; Operate any system or component that does not
NW WASHINGTON HOME INSPECTIONS LLC Houdek
51 Point View Ave Page 3 of 48
respond to normal operating controls; Disturb insulation, move personal items, panels, furniture, equipment, plant life, soil, snow, ice, or debristhat obstructs access or visibility; Determine the presence or absence of any suspected adverse environmental condition or hazardoussubstance, including but not limited to mold, toxins, carcinogens, noise, contaminants in the building or in soil, water, and air; Determine theeffectiveness of any system installed to control or remove suspected hazardous substances; Predict future condition, including but not limitedto failure of components; Since this report is provided for the specific benefit of the customer(s), secondary readers of this information shouldhire a licensed inspector to perform an inspection to meet their specific needs and to obtain current information concerning this property.
Type of building::Single Family (1 story)
Approximate Square Footage::1400
Approximate Year of OriginalConstruction::1994
Inspection started at::9am
Inspection ended at::11:30am
Occupancy::The home was occupied
Attending the Inspection::Seller
Weather during the Inspection::Light Rain
Significant precipitation in last 3 days::No
Temperature during inspection::Over 60 (F) = 15.5 (C)
Ground/Soil surface condition:Dry
NW WASHINGTON HOME INSPECTIONS LLC Houdek
51 Point View Ave Page 4 of 48
Significant IssuesSignificant Issues = Items or discoveries indicate that these systems or components may cost significant money tocorrect now or in the near future, or items that require immediate attention to prevent additional damage or eliminatesafety hazards.
1. Roof
1.0 Roof Structure Exterior(1) The asphalt roof on this home is in fair condition reflecting it's 20+ service year life (the roof appears to beoriginal to the house). Some repairs and replacement shingles are evident. Shingles are becoming less flexible withage and granular loss is evident on the surface of the shingle.
I would recommend budgeting for a replacement roof.
6. Electrical
6.9 Service Panel WiringNoted wiring (see photo) in main electrical panel is most likely the electrical supply line for the electrical panel in thedetached garage. The combined potential load on the main feeder line may exceed the rated capacity of the mainelectrical line from the meter (200 amps).
The detached garage and it's electrical panel in the workshop was not inspected.
Recommend further assessment of the additional electrical panel, the secondary electrical panel, its' power supplywiring, panel configuration, breaker protection, and wiring by a licensed electrician.
Please note this section is not all-inclusive, please read the complete report.
NW WASHINGTON HOME INSPECTIONS LLC Houdek
51 Point View Ave Page 5 of 48
Repair & Maintenance SummaryRepair & Maintenance Issues = Items or discoveries indicate that these systems or components do not function asintended and/or maintenance is required in the near term. Further investigation by a specialist and/or subsequentobservation may be required.
1. Roof
1.0 Roof Structure Exterior(3) Paneled plastic roofing over the deck is noted. This should be kept clear of debris. Please note, this material willgenerally not support the weight of a person.
1.2 Roof Flashing(1) No flashing appears to have been used in the area of transition from the asphalt roof to the flat roof at the eave.In periods of heavy rain, water has penetrated this area, causing some rot of the soffit detail and sheathing.Conditions are further conducive to wood destroying organisms.
Recommend repair by a licensed roofing contractor.
1.3 Roof Drainage System(1) Recommend continued periodic cleaning of the gutters.
(2) The discharge from the gutter downspout in back of house is un-managed. Water should be positively shedaway from the house, especially in this area with marginal grading for water shedding.
Recommending extending downspout 4 to 6 feet away from the house by means of extension to an area of gradeaway from the structure.
2. Attic
2.3 Roof Structure VentilationThe attic void is very small and well insulated. Ventilation is solely provided by gable vents. Some minor organicgrowth is evident in a few areas on the underside of the roof sheathing. Consider commissioning a licensed roofingcontractor to add some additional means of attic ventilation (roof vents, soffit vents, ridge vent or combinationthereof) when the roof is replaced.
3. Exterior
3.3 General Grounds(2) Trees need to be trimmed back 2 to 3 feet from the roof eaves around the entire perimeter of the sides and backof the house. Contact with the structure can cause physical damage and act as a means of entry for rodents,animals, and pests.
3.6 Deck, Balcony, Bridge and Porch,(1) Deck and deck stair railings do not meet current safety standards for height or method of construction.
Recommend consulting a licensed decking or general contractor for improvement and/or replacement options.
(2) Some rot was found in the handrail on the front deck by the kitchen.
NW WASHINGTON HOME INSPECTIONS LLC Houdek
51 Point View Ave Page 6 of 48
Recommend removal and replacement of rotten rail.
(3) Typical deck construction is not designed to support the weight of a water filled hot-tub. No additional supportwas apparent.Recommend consulting a decking contractor for options to additionally support the deck in the area of the hot-tub.
3.7 Exterior StairsConsider improving/replacing front entry steps with more substantial system as this is the primary means to enterthe home.
3.8 Retaining wallsWooden boards used as flower bed partition in the front of the house under the decking are rotten and decaying.Recommend removal and replacement with a masonry product or treated lumber. This condition is furtherconducive to wood destroying organisms.
6. Electrical
6.21 Carbon Monoxide DetectorsNo carbon monoxide detectors were installed at the time of the inspection. Carbon monoxide is an odorless,colorless, tasteless, toxic gas that is a product of the combustion process. Combustion appliances such as gasfurnaces and heaters can introduce dangerously high levels of carbon monoxide onto the indoor air if combustioncomponents need adjustment. Carbon monoxide detectors monitor indoor air and sound an alarm if dangerouslyhigh levels of carbon monoxide are detected.
The Inspector recommends installation of a carbon monoxide detector in the hallway outside the sleeping areas by aqualified contractor.
7. Interior
7.3 LightingSeveral recessed lights in the kitchen were noted to not work. Several had the bulbs removed. Recommendreplacing the bulbs. Recommend further troubleshooting by a licensed electrician if required.
7.5 DoorsRigid foam insulation has been installed on the back of the furnace closet door. Unless fire rated, rigid foaminsulation is a fire hazard and should be covered or removed from a utility closet with combustion appliances.
7.6 Windows and SkylightsSeveral windows have slight fog or staining inside panes indicating broken seal. Recommend replacing the glass ata convenient time.
8. Plumbing
8.4 Propane Water Heater(2) The pressure relief line is not properly connected at the joints. I was unable to determine if the piping is rated forhigh temperature water.
Recommend repair and replacement if necessary by a licensed plumber.
(3) Recommend plumbing the drain line of the pan to the exterior to help prevent water damage to the home in theevent of a leak. Recommend repairs by a licensed plumber.
NW WASHINGTON HOME INSPECTIONS LLC Houdek
51 Point View Ave Page 7 of 48
(4) The hot water heater is delivering water too hot to the plumbing system, measured at 133 deg F at the kitchensink. This poses a scalding risk. Recommend adjusting the hot water heater temperature to deliver 120 deg F atthe sink and showers, etc. A licensed plumber can make the adjustment.
9. Heating
9.1 FurnaceThe third heating element on the furnace failed to light and the furnace shut-down on a safety override two cyclesbefore the element eventually light (I let the unit sit and tried again 20 minutes later). No record of recent servicingwas posted, annual is recommended.
Recommend servicing and troubleshooting by a licensed heating contractor.
9.3 ThermostatThermostat display was dim and difficult to read. Some numbers are distorted.
Recommend troubleshoot/repair/replacement by a licensed heating contractor.
9.4 Filter conditionFilter was dirty and requires replacement.
11. Kitchen and Built-in Appliances
11.9 CabinetsKitchen cabinet door requires adjustment.
11.10 Kitchen AppliancesHot water dispenser mounted in the kitchen sink is loose and requires tightening.
11.11 RangeFront left burner of range would only light when back left burner lighted. The down-draft would only run when the leftside burners were running. The range/oven combination appears original to the house and has exceeded it'sexpected appliance life expectancy.
Recommend repair or replacement of range/oven by a licensed appliance technician.
12. Laundry Room
12.0 FloorsLaundry fan is not operational. Wall switch appears to have been removed. Fan removes moisture from the roomas a result of using the washer/dryer.
Recommend repair/replace by a licensed electrician.
NW WASHINGTON HOME INSPECTIONS LLC Houdek
51 Point View Ave Page 8 of 48
Please note this section is not all-inclusive, please read the complete report.
NW WASHINGTON HOME INSPECTIONS LLC Houdek
51 Point View Ave Page 9 of 48
Complete Wood Destroying Organism Inspection ReportComplete Wood Destroying Organism Inspection Report: This report identifies the presence of wood destroyingorganisms or conditions conducive to wood destroying organisms. Conducive conditions include but are not limited to,inadequate clearances, earth/wood contact, cellulose debris, inadequate ventilation, and excessive moisture. PestInspection Standards in Washington State, WAC 16-228-2045 - requires that a diagram / drawing be prepared forwood destroying organism (WDO) Reports. If the photos and descriptions in this report are inadequate, a drawingis available upon request.
WSDA ICN # 10208AR001
_________________________________________________________________________________________________________
Summary of Findings:
Visible Evidence of Active Wood Destroying Insects: None Noted / Present
Visible Evidence of Inactive Wood Destroying Insects: None Noted / Present
Visible Evidence of Active Wood Decaying Fungi: None Noted / Present
Visible Evidence of Damage by Wood Destroying Organisms: None Noted / Present
Visible Evidence of Conditions Conducive to Wood Destroying Organisms: None Noted / Present
_________________________________________________________________________________________________________
Moisture Meter Testing: Where moisture meter testing is indicated in this report a GE Protimeter BLD5365 SurveymasterDual-Function Moisture Meter was used.
Standard Limitations: Complete WDO inspections will identify conditions present at a subject property at the time of an inspection. Inspectorsare not required to report on any WDO infestation or other condition that might be subject to seasonal constraints or environmental condition ifevidence of those constraints or conditions is not visible at the time of inspection. Please note that most WDO observations are related to highmoisture conditions that could be conducive to mold-like substances. NORTHWEST WASHINGTON HOME INSPECTIONS LLC is not a moldspecialist and recommends consulting with an industrial hygienist or other mold remediation expert if concerned about mold or indoor airquality.
1. Roof
1.2 Roof Flashing(1) No flashing appears to have been used in the area of transition from the asphalt roof to the flat roof at the eave.In periods of heavy rain, water has penetrated this area, causing some rot of the soffit detail and sheathing.Conditions are further conducive to wood destroying organisms.
Recommend repair by a licensed roofing contractor.
3. Exterior
3.3 General Grounds(2) Trees need to be trimmed back 2 to 3 feet from the roof eaves around the entire perimeter of the sides and backof the house. Contact with the structure can cause physical damage and act as a means of entry for rodents,animals, and pests.
3.6 Deck, Balcony, Bridge and Porch,
NW WASHINGTON HOME INSPECTIONS LLC Houdek
51 Point View Ave Page 10 of 48
(2) Some rot was found in the handrail on the front deck by the kitchen.
Recommend removal and replacement of rotten rail.
3.8 Retaining wallsWooden boards used as flower bed partition in the front of the house under the decking are rotten and decaying.Recommend removal and replacement with a masonry product or treated lumber. This condition is furtherconducive to wood destroying organisms.
NW WASHINGTON HOME INSPECTIONS LLC Houdek
51 Point View Ave Page 11 of 48
1. RoofThe roof inspection portion of the General Home Inspection will not be as comprehensive as an inspection performed by a qualified roofing contractor.Because of variations in installation requirements of the huge number of different roof-covering materials installed over the years, the General HomeInspection does not include confirmation of proper installation. Home Inspectors are trained to identify common deficiencies and to recognizeconditions that require evaluation by a specialist. Inspection of the roof typically includes visual evaluation of the roof structure, roof-coveringmaterials, flashing, and roof penetrations like chimneys, mounting hardware for roof-mounted equipment, attic ventilation devices, ducts forevaporative coolers, and combustion and plumbing vents. The roof inspection does not include leak-testing and will not certify or warranty the roofagainst future leakage. Other limitations may apply and will be included in the comments as necessary.
Styles & Materials
Method of inspection:Walked the roof
The roof style was:GableLow-slope
Primary roof-covering type:3-tab Fiberglass Asphalt ShingleModified bitumen
Drainage system description:Gutters and downspouts installed
Underlayment/Interlayment::Black Felt
Sky Light(s):Three
Items
1.0 Roof Structure ExteriorComments: Inspected
(1) The asphalt roof on this home is in fair condition reflecting it's 20+ service year life (the roof appearsto be original to the house). Some repairs and replacement shingles are evident. Shingles are becoming lessflexible with age and granular loss is evident on the surface of the shingle.
I would recommend budgeting for a replacement roof.
1.0 (1) Asphalt Shingle Roof 1.0 (2) Asphalt Shingle Roof #2
NW WASHINGTON HOME INSPECTIONS LLC Houdek
51 Point View Ave Page 12 of 48
1.0 (3) Asphalt Roof #3
1.0 (4) Replaced shingles
1.0 (5) Granular degradation with age
NW WASHINGTON HOME INSPECTIONS LLC Houdek
51 Point View Ave Page 13 of 48
1.1 UnderlaymentComments: Limitation
1.2 Roof FlashingComments: Inspected
(2) This flat roof is a modified bitumen or equivalent roofing system. The protective coating is starting to crackand become brittle. Refreshing the protective coat or replacing the entire roof at the same time the asphaltroof is addressed in the future is advisable.
1.0 (6) Low Slope Roof 1.0 (7) Loof Slope Roof #2
(3) Paneled plastic roofing overthe deck is noted. This should be keptclear of debris. Please note, thismaterial will generally not support theweight of a person.
1.0 (8) Plastic Deck Roofing
Inspected from roof edge or where visible.
NW WASHINGTON HOME INSPECTIONS LLC Houdek
51 Point View Ave Page 14 of 48
(1) No flashing appears to have been used in the area of transition from the asphalt roof to the flatroof at the eave. In periods of heavy rain, water has penetrated this area, causing some rot of the soffit detailand sheathing. Conditions are further conducive to wood destroying organisms.
Recommend repair by a licensed roofing contractor.
1.2 (1) Area of water damage 1.2 (2) No flashing
1.2 (3) No flashing
NW WASHINGTON HOME INSPECTIONS LLC Houdek
51 Point View Ave Page 15 of 48
1.3 Roof Drainage SystemComments: Inspected
(2) No flashing was used at the roofedge, relying on the shingle overlay toprotect the edge of the deck sheathingfrom damage. Consider adding edgeflashing, perhaps when the roof isreplaced as additional protection forthe roof substructure.
1.2 (4) No flashing at roof edge
(1) Recommend continuedperiodic cleaning of the gutters.
1.3 (1) Front gutters
NW WASHINGTON HOME INSPECTIONS LLC Houdek
51 Point View Ave Page 16 of 48
1.4 Plumbing and Combustion VentsComments: Inspected
1.5 Asphalt Composition ShingleComments: Inspected
The roof of the home was inspected and reported on with the above information. Any repair items mentioned in this report should be consideredbefore purchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates to the comments in thisinspection report.
(2) The discharge from the gutterdownspout in back of house is un-managed. Water should be positivelyshed away from the house, especiallyin this area with marginal grading forwater shedding.
Recommending extending downspout4 to 6 feet away from the house bymeans of extension to an area ofgrade away from the structure.
1.3 (2)
NW WASHINGTON HOME INSPECTIONS LLC Houdek
51 Point View Ave Page 17 of 48
2. AtticInspection of the attic typically includes visual examination the following:roof structure (framing and sheathing); roof structure ventilation; thermalenvelope; electrical components (wiring, junction boxes, outlets, switches and lighting); plumbing components (supply and vent pipes, bathroom ventterminations) and HVAC components (drip pans, ducts, condensate and TPR discharge pipes).
Styles & Materials
Attic info:Scuttle hole
Attic inspected from:Access Hatch (inadequate headroom)
Attic thermal insulation material:Blown-in Fiberglass
Approximate attic thermal insulationdepth:
R-19 or better
Roof structure ventilation device type:Gable vents
Roof Framing Type:Combination of Conventional Framing
and Roof Trusses
Roof Sheathing Material:Oriented Strand Board (OSB)
Items
2.0 Attic AccessComments: Limitation
2.1 Roof Framing (from attic)Comments: Inspected
2.2 Roof SheathingComments: Inspected
2.3 Roof Structure VentilationComments: Inspected
The attic space lacked adequate headroom for safe entry. The attic was inspected from the access hatch inthe bedroom closet.
Slight discoloration of the deck sheathing is noted. Maintain vents
NW WASHINGTON HOME INSPECTIONS LLC Houdek
51 Point View Ave Page 18 of 48
2.4 Attic ElectricalComments: Not Inspected
2.5 Venting Systems (Kitchens, Baths and Laundry)Comments: Not Inspected
2.6 Attic Rodent ActivityComments: Inspected
The attic of the home was inspected and reported on with the above information. Any repair items mentioned in this report should be consideredbefore purchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates to the comments in thisinspection report.
The attic void is very small and well insulated. Ventilation is solely provided by gable vents. Some minororganic growth is evident in a few areas on the underside of the roof sheathing. Consider commissioning alicensed roofing contractor to add some additional means of attic ventilation (roof vents, soffit vents, ridge ventor combination thereof) when the roof is replaced.
2.3 (1) sheathing area of concern 2.3 (2) Gable vent
Not visible.
NW WASHINGTON HOME INSPECTIONS LLC Houdek
51 Point View Ave Page 19 of 48
3. ExteriorInspection of the home exterior typically includes: exterior wall covering materials; exterior trim; window and door exteriors; adequate surfacedrainage; driveway and walkways; window wells; exterior electrical and plumbing components; and retaining wall conditions that may affect the homestructure. The potential for dangers/damage associated with trees- such as falling branches or root damage to foundations- varies with tree speciesand age, and requires an arborist evaluation.
The General Home Inspection does not include inspection of landscape irrigation systems, fencing or swimming pools/spas.
Styles & Materials
Driveway Material:Gravel
Walkway Materials:GravelDirt
Appurtenance:Deck with steps
Downspout Discharge:Above Grade
Lot Description:Moderate Slope
Clearance to Grade:Non-Standard
Items
3.0 Exterior ViewsComments: Inspected
3.1 DrivewayComments: Inspected
3.2 WalkwaysComments: Inspected
3.3 General GroundsComments: Inspected
(1) Grade in back of house is challenging from a water management standpoint. Be sure to keep debris clearand vents above grade as much as possible so that water does not flow into crawlspace or along foundationwall.
3.3 (1) Low clearance 3.3 (2) Back crawlspace vents
NW WASHINGTON HOME INSPECTIONS LLC Houdek
51 Point View Ave Page 20 of 48
3.4 Exterior TrimComments: Inspected
3.5 PorchComments: Inspected
3.6 Deck, Balcony, Bridge and Porch,Comments: Inspected
(2) Trees need to be trimmed back 2 to 3 feet from the roof eaves around the entire perimeter of thesides and back of the house. Contact with the structure can cause physical damage and act as a means ofentry for rodents, animals, and pests.
3.3 (3) Vegetation #1 3.3 (4) Vegetation #2
3.3 (5) Vegetation #3
NW WASHINGTON HOME INSPECTIONS LLC Houdek
51 Point View Ave Page 21 of 48
(1) Deck and deck stair railings do not meet current safety standards for height or method ofconstruction.
Recommend consulting a licensed decking or general contractor for improvement and/or replacement options.
3.6 (1) 2 ' railing
3.6 (2) In-sufficient hand rail.
3.6 (3) No handrail
3.6 (4) Deck - approx 3 feet high
NW WASHINGTON HOME INSPECTIONS LLC Houdek
51 Point View Ave Page 22 of 48
3.6 (5) No balusters - max 4"
(2) Some rot was found inthe handrail on the front deck by thekitchen.
Recommend removal andreplacement of rotten rail.
3.6 (6)
NW WASHINGTON HOME INSPECTIONS LLC Houdek
51 Point View Ave Page 23 of 48
3.7 Exterior StairsComments: Inspected
3.8 Retaining wallsComments: Inspected
(3) Typical deck construction is not designed to support the weight of a water filled hot-tub. No additionalsupport was apparent.Recommend consulting a decking contractor for options to additionally support the deck in the area of the hot-tub.
3.6 (7) Hot tub - front deck 3.6 (8) Area below hot-tub
Consider improving/replacingfront entry steps with more substantialsystem as this is the primary means toenter the home.
3.7 (1) Front yard steps
NW WASHINGTON HOME INSPECTIONS LLC Houdek
51 Point View Ave Page 24 of 48
3.9 Additional StructuresComments: Not Inspected
Wooden boards used as flower bed partition in the front of the house under the decking are rottenand decaying. Recommend removal and replacement with a masonry product or treated lumber. Thiscondition is further conducive to wood destroying organisms.
3.8 (1) Rotten flower bed lining 3.8 (2)
Four additional structures are noted on the property and were not inspected as they are beyond the scope ofthe home inspection.
3.9 (1) Covered parking - structure #1 3.9 (2) Old building - structure #2
NW WASHINGTON HOME INSPECTIONS LLC Houdek
51 Point View Ave Page 25 of 48
3.10 Water FeaturesComments: Not Inspected
The exterior of the home was inspected and reported on with the above information. Any repair items mentioned in this report should be consideredbefore purchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates to the comments in thisinspection report.
3.9 (3) Detached garage and workshop - structure #3 3.9 (4) Pump house - structure #4
A hot tub is installed on the front deck. The hot tub was not inspected as it is beyond the scope of theinspection.
3.10 (1) Hot tub #1 3.10 (2) Hot tub #2
NW WASHINGTON HOME INSPECTIONS LLC Houdek
51 Point View Ave Page 26 of 48
4. Wall ExteriorsInspection of the home exterior typically includes: exterior wall covering materials; exterior trim; window and door exteriors; adequate surfacedrainage; driveway and walkways; window wells; exterior electrical and plumbing components; and retaining wall conditions that may affect the homestructure. The potential for dangers/damage associated with trees- such as falling branches or root damage to foundations- varies with tree speciesand age, and requires an arborist evaluation.
The General Home Inspection does not include inspection of landscape irrigation systems, fencing or swimming pools/spas.
Styles & Materials
Exterior wall-covering Material:Vinyl Siding
Exterior Doors:Hollow coreFiberglass
Items
4.0 Door ExteriorsComments: Inspected
4.1 Window ExteriorsComments: Inspected
4.2 Exterior Wall PenetrationsComments: Inspected
4.3 Exterior Wall MembraneComments: Inspected
The exterior of the home was inspected and reported on with the above information. Any repair items mentioned in this report should be consideredbefore purchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates to the comments in thisinspection report.
NW WASHINGTON HOME INSPECTIONS LLC Houdek
51 Point View Ave Page 27 of 48
5. StructureThe General Home Inspection includes inspection of the home structural elements that were readily visible at the time of the inspection. This mayinclude the: foundation; walls; floor structure; and/or roof structure. Soils vary in their stability and ability to support the weight of a structure. Minorcracking is normal with some common foundation materials, is typically limited to the material surface, is not a structural concern, and may not becommented on. Cracking related to soil/foundation movement indicates the potential for present or future structural concerns and will be commentedon to the best of the inspector's ability.
Much of the home structure is hidden behind exterior and interior roof, floor, wall, and ceiling coverings, or is buried underground. Because theGeneral Home Inspection is limited to visual and non-invasive methods, this report may not identify all structural deficiencies. Identification of portionsof the wall structure not directly visible requires logical assumptions on the part of the Inspector that are based on the Inspectors past experience andknowledge of common building practices.
Upon observing indications that structural problems may exist that are not readily visible, or the evaluation of which lies beyond the Inspector'sexpertise, the inspector may recommend evaluation or testing by a specialist that may include invasive measures, which would require homeownerpermission.
Styles & Materials
Typical Ceiling Structure:Drywall attached to dimensional lumber
ceiling joists
Exterior Wall Structures:Wood Frame
Wall Insulation:Not Visible
Foundation Configuration:Crawlspace
Foundation Method/Materials:Poured concrete foundation walls
Main Floor Structure:Plywood sheathing over Engineered floor
joists
Main Floor Structure- Perimeter Bearing:Rests on top of foundation wall
Main Floor Structure- IntermediateSupport:
Wood beam girderConcrete Piers
Floor System Insulation:BattsFiberglass
Evidence of Seismic Protection:None Noted
Crawl Space Vapor Barrier:6 Mil Poly
Items
5.0 Exterior Wall ConstructionComments: Inspected
5.1 Floor StructureComments: Inspected
5.2 Insulation Under Floor SystemComments: Inspected
5.3 FoundationComments: Inspected
5.4 Crawl Space Moisture ConditionsComments: Inspected
5.5 Crawl Space Rodent ActivityComments: Inspected
5.6 Wood Destroying OrganismsComments: Inspected
The structure of the home was inspected and reported on with the above information. Any repair items mentioned in this report should be consideredbefore purchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates to the comments in thisinspection report.
NW WASHINGTON HOME INSPECTIONS LLC Houdek
51 Point View Ave Page 28 of 48
6. ElectricalOver the years, many different types and brands of electrical components have been installed in homes. Electrical components and standards havechanged and continue to change. Homes electrical systems are not required to be updated to meet newly enacted electrical codes or standards. Fulland accurate inspection of electrical systems requires contractor-level experience. For this reason, full inspection of home electrical systems liesbeyond the scope of the General Home Inspection.
The General Home Inspection is limited to identifying common electrical requirements and deficiencies. Conditions indicating the need for a morecomprehensive inspection will be referred to a qualified electrical contractor.Inspection of the home electrical system typically includes visualinspection of the following:service drop: conductors, weatherhead, and service mast; electric meter exterior; service panel and sub-panels; serviceand equipment grounding; system and component bonding; and visible branch wiring: receptacles (representative number), switches, lighting
Styles & Materials
Electrical Service Conductors:Underground serviceAluminum120/240 volt service
Service Panel Ampacity:200 amps
Service Panel Type:Load Center
Service Panel Manufacturer:Square D
Service Disconnect Location:At Service Panel
Service Disconnect Type:Breaker
Service Grounding Electrode:Not Visible
Wiring Methods:Romex
Type of Branch Wiring:Solid Copper
Ground Fault Circuit Interruptor (GFCI)Protection:
YES
Arc Fault Circuit Interruptor (AFCI)Protection:
NO
Items
6.0 General Electrical System DescriptionComments: Inspected
6.1 General Electrical System ConditionComments: Inspected
6.2 Service Drop, Drip Loop, Splice and AttachmentComments: Inspected
6.3 Mast & WeatherheadComments: Inspected
6.4 Electric MeterComments: Inspected
6.5 Service Entrance ConductorsComments: Inspected
6.6 Service Panel ManufacturerComments: Inspected
6.7 Service Panel Exposure RatingComments: Inspected
6.8 Service Panel Cabinet, Ampacity, and CoverComments: Inspected
6.9 Service Panel WiringComments: Inspected
NW WASHINGTON HOME INSPECTIONS LLC Houdek
51 Point View Ave Page 29 of 48
6.10 Service DisconnectComments: Inspected
6.11 Overcurrent Protection DevicesComments: Inspected
6.12 Service Grounding Electrode System & Service BondComments: Inspected
6.13 Equipment Grounding & BondingComments: Inspected
6.14 Exterior Electrical ReceptaclesComments: Inspected
6.15 Conventional Electrical Receptacles (interior)Comments: Inspected
6.16 GFCI/AFCI Electrical ReceptaclesComments: Inspected
Noted wiring (see photo) in mainelectrical panel is most likely theelectrical supply line for the electricalpanel in the detached garage. Thecombined potential load on the mainfeeder line may exceed the ratedcapacity of the main electrical linefrom the meter (200 amps).
The detached garage and it's electricalpanel in the workshop was notinspected.
Recommend further assessment ofthe additional electrical panel, thesecondary electrical panel, its' powersupply wiring, panel configuration,breaker protection, and wiring by alicensed electrician.
6.9 (1) Main Electrical Panel
NW WASHINGTON HOME INSPECTIONS LLC Houdek
51 Point View Ave Page 30 of 48
6.17 SwitchesComments: Inspected
6.18 LightingComments: Inspected
6.19 Visible Branch WiringComments: Inspected
6.20 Smoke DetectorsComments: Inspected
6.21 Carbon Monoxide DetectorsComments: Inspected
6.22 DoorbellComments: Inspected
The electrical system of the home was inspected and reported on with the above information. Outlets were not removed and the inspection was onlyvisual. Any outlet not accessible (behind the refrigerator for example) was not inspected or accessible. Any repair items mentioned in this reportshould be considered before purchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates tothe comments in this inspection report.
No carbon monoxide detectorswere installed at the time of theinspection. Carbon monoxide is anodorless, colorless, tasteless, toxicgas that is a product of thecombustion process. Combustionappliances such as gas furnaces andheaters can introduce dangerouslyhigh levels of carbon monoxide ontothe indoor air if combustioncomponents need adjustment. Carbonmonoxide detectors monitor indoor airand sound an alarm if dangerouslyhigh levels of carbon monoxide aredetected.
The Inspector recommendsinstallation of a carbon monoxidedetector in the hallway outside thesleeping areas by a qualifiedcontractor.
6.21 (1) No carbon monoxide detector
NW WASHINGTON HOME INSPECTIONS LLC Houdek
51 Point View Ave Page 31 of 48
7. InteriorInspection of the home interior does not include testing for mold, radon, asbestos, lead paint, or other environmental hazards unless specificallyrequested as an ancillary inspection. Inspection of the home interior typically includes: interior wall, floor and ceiling coverings and surfaces; doorsand windows: condition, hardware, and operation; interior trim: baseboard, casing, molding, etc.; permanently-installed furniture, countertops,shelving, and cabinets; and ceiling and whole-house fans.
Styles & Materials
Walls and Ceilings:Drywall
Floor Covering Materials:CarpetSheet Vinyl
Interior Doors:Hollow
Window Material:Vinyl
Window Glazing:Double-pane
Window Operation:Sliding
Smoke/CO Detectors:Smoke detectors installed (hardwired)Carbon Monoxide detectors were not
installed
Items
7.0 FloorsComments: Inspected
7.1 WallsComments: Inspected
7.2 CeilingsComments: Inspected
7.3 LightingComments: Inspected
7.4 Misc. Components: Ceiling fans, doorbells, Env. Hazards, Detectors, etc.Comments: Inspected
Several recessed lights in the kitchen were noted to not work. Several had the bulbs removed.Recommend replacing the bulbs. Recommend further troubleshooting by a licensed electrician if required.
7.3 (1) Inoperable recessed lights 7.3 (2) No bulbs
NW WASHINGTON HOME INSPECTIONS LLC Houdek
51 Point View Ave Page 32 of 48
7.5 DoorsComments: Inspected
7.6 Windows and SkylightsComments: Inspected
Rigid foam insulation has beeninstalled on the back of the furnacecloset door. Unless fire rated, rigidfoam insulation is a fire hazard andshould be covered or removed from autility closet with combustionappliances.
7.5 (1) Rigid Foam Insulation - furnace closet
Several windows have slight fog or staining inside panes indicating broken seal. Recommend replacingthe glass at a convenient time.
7.6 (1) Bedroom widow #1 7.6 (2) Bedroom window #2
NW WASHINGTON HOME INSPECTIONS LLC Houdek
51 Point View Ave Page 33 of 48
7.7 Interior TrimComments: Inspected
7.8 Cabinets and CountertopsComments: Inspected
7.9 StairsComments: Inspected
7.10 Bathroom and Laundry VentilationComments: Inspected
The interior of the home was inspected and reported on with the above information. The inspection did not involve moving furniture and inspectingbehind furniture, area rugs or areas obstructed from view. Any repair items mentioned in this report should be considered before purchase. It isrecommended that qualified contractors be used in your further inspection or repair issues as it relates to the comments in this inspection report.
7.6 (3) Bedroom windows #3 and #4
NW WASHINGTON HOME INSPECTIONS LLC Houdek
51 Point View Ave Page 34 of 48
8. PlumbingInspection of the plumbing system typically includes (limited) operation and visual inspection of: water supply source (identification as public orprivate); sewage disposal system (identification as public or private); water supply/distribution pipes; drain, waste and vent (DWV) system; waterheater (type, condition and operation); gas system; and sump pump (confirmation of installation/operation).
Styles & Materials
Water Supply Source:Private well on property
Main Water Supply Pipe:Not Visible
Main Water Supply Location:Not Located
Water Distribution Pipes:1/2-inch and 3/4-inch copper
Distribution Pipe Bonding:Pipes were bonded
Sewage System Type:Septic system
Drain Waste and Vent Pipe Materials:Acrylonitrile butadiene styrene (ABS)
Water Heater Manufacturer:Bradford White
Date of Manufacture:2011
Water Heater Fuel Type:Propane
Water Heater Type:Tank (conventional)
Water Heater Tank Capacity:50 gallons
Water Heater Location:Washer Dryer Room
Washer Drain Size:2" Diameter
Gas Pipe Material:Corrugated Stainless Steel Tubing
(CSST)Copper
Type of Gas:Propane
Items
8.0 Exterior PlumbingComments: Inspected
8.1 Source of WaterComments: Inspected
8.2 Water Supply and DistributionComments: Inspected
8.3 Sewage and DWV SystemsComments: Inspected
8.4 Propane Water HeaterComments: Inspected
NW WASHINGTON HOME INSPECTIONS LLC Houdek
51 Point View Ave Page 35 of 48
(1) Propane converted water heater.
8.4 (1)
8.4 (2)
NW WASHINGTON HOME INSPECTIONS LLC Houdek
51 Point View Ave Page 36 of 48
(2) The pressure relief line is not properly connected at the joints. I was unable to determine if the pipingis rated for high temperature water.
Recommend repair and replacement if necessary by a licensed plumber.
8.4 (3) Hot water heater pressure relief dischargepiping
8.4 (4) #2
(3) Recommend plumbing thedrain line of the pan to the exterior tohelp prevent water damage to thehome in the event of a leak.Recommend repairs by a licensedplumber.
8.4 (5)
NW WASHINGTON HOME INSPECTIONS LLC Houdek
51 Point View Ave Page 37 of 48
The plumbing in the home was inspected and reported on with the above information. Washing machine drain line for example cannot be checked forleaks or the ability to handle the volume during drain cycle. Older homes with galvanized supply lines or cast iron drain lines can be obstructed andbarely working during an inspection but then fails under heavy use. If the water is turned off or not used for periods of time (like a vacant home waitingfor closing) rust or deposits within the pipes can further clog the piping system. Any repair items mentioned in this report should be considered beforepurchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates to the comments in thisinspection report.
The plumbing in the home was inspected and reported on with the above information. Washing machine drain line for example cannot be checked forleaks or the ability to handle the volume during drain cycle. Older homes with galvanized supply lines or cast iron drain lines can be obstructed andbarely working during an inspection but then fails under heavy use. If the water is turned off or not used for periods of time (like a vacant home waitingfor closing) rust or deposits within the pipes can further clog the piping system. Any repair items mentioned in this report should be considered beforepurchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates to the comments in thisinspection report.
(4) The hot water heater isdelivering water too hot to theplumbing system, measured at 133deg F at the kitchen sink. This posesa scalding risk. Recommend adjustingthe hot water heater temperature todeliver 120 deg F at the sink andshowers, etc. A licensed plumber canmake the adjustment.
8.4 (6) 133 deg F at the kitchen sink
NW WASHINGTON HOME INSPECTIONS LLC Houdek
51 Point View Ave Page 38 of 48
9. HeatingHeating system inspection will not be as comprehensive as that performed by a qualified heating, ventilating, and air-conditioning (HVAC) systemcontractor. For example: identification of cracked heat exchangers requires a contractor evaluation. Report comments are limited to identification ofcommon requirements and deficiencies. Observed indications that further evaluation is needed will result in referral to a qualified HVAC contractor.The general home inspection does not include any type of heating system warranty or guaranty. Inspection of heating systems is limited to basicevaluation based on visual examination and operation using normal controls. Report comments are limited to identification of common requirementsand deficiencies. Observed indications that further evaluation is needed will be referred to a qualified heating, ventilating, and air-conditioning (HVAC)contractor. Inspection of heating systems typically includes (limited) operation and visual inspection of: the heating appliance (confirmation ofadequate response to the call for heat); proper heating appliance location; proper or adequate heating system configuration; exterior cabinetcondition; fuel supply configuration and condition; combustion exhaust venting; heat distribution components; proper condensation discharge; andtemperature/pressure relief valve and discharge pipe (presence, condition, and configuration).
Styles & Materials
Heating System Type:Propane--fired Furnace
Energy Source:Propane
Number of Heat Systems (excludingwood):
One
Heating/Cooling Ducts:Partially insulated
Air Filter:Disposable
Air Filter Location:Behind removable panel at furnace
Heating System Brand:Trane
Types of FIreplaces:None
Items
9.0 Presence of installed heat source in each roomComments: Inspected
9.1 FurnaceComments: Inspected
NW WASHINGTON HOME INSPECTIONS LLC Houdek
51 Point View Ave Page 39 of 48
9.2 Fuel, Piping and SupportComments: Inspected
9.3 ThermostatComments: Inspected
9.4 Filter conditionComments: Inspected
The third heating element on the furnace failed to light and the furnace shut-down on a safety overridetwo cycles before the element eventually light (I let the unit sit and tried again 20 minutes later). No record ofrecent servicing was posted, annual is recommended.
Recommend servicing and troubleshooting by a licensed heating contractor.
9.1 (1) Propane furnace
9.1 (2) 3rd burner
Thermostat display was dim anddifficult to read. Some numbers aredistorted.
Recommend troubleshoot/repair/replacement by a licensed heatingcontractor.
9.3 (1) Thermostat - hallway
NW WASHINGTON HOME INSPECTIONS LLC Houdek
51 Point View Ave Page 40 of 48
9.5 Heaters, Propane-firedComments: Not Inspected
The heating system of this home was inspected and reported on with the above information. The inspection is not meant to be technically exhaustive.The inspection does not involve removal and inspection behind service door or dismantling that would otherwise reveal something only a licensedheat contractor would discover. Any repair items mentioned in this report should be considered before purchase. It is recommended that qualifiedcontractors be used in your further inspection or repair issues as it relates to the comments in this inspection report.
Filter was dirty and requiresreplacement.
9.4 (1)
Auxiliary propane wall heater did not operate when attempted to test. This unit may have not been used for awhile.
Recommend troubleshoot/repair by a licensed heating contractor.
9.5 (1) Auxiliary heating unit - kitchen
9.5 (2) label plate
NW WASHINGTON HOME INSPECTIONS LLC Houdek
51 Point View Ave Page 41 of 48
10. BathroomsInspection of the bathrooms typically includes the following:walls, floors and ceiling; sink (basin, faucet, overflow); cabinets (exteriors, doors, drawers,undersink); toilet/bidet tub and shower (valves, showerhead, walls, enclosure); electrical (outlets, lighting); and room ventilation
Styles & Materials
Exhaust Fans:Fan with light
Items
10.0 FloorsComments: Inspected
10.1 WallsComments: Inspected
10.2 CeilingsComments: Inspected
10.3 DoorsComments: Inspected
10.4 WindowsComments: Inspected
10.5 SkylightsComments: Inspected
10.6 Electrical Receptacles and SwitchesComments: Inspected
10.7 LightingComments: Inspected
10.8 VentilationComments: Inspected
10.9 CabinetsComments: Inspected
10.10 ToiletComments: Inspected
10.11 ShowerComments: Inspected
10.12 Medicine CabinetComments: Inspected
10.13 MirrorsComments: Inspected
The bathrooms of the home was inspected and reported on with the above information. Any repair items mentioned in this report should beconsidered before purchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates to thecomments in this inspection report.
NW WASHINGTON HOME INSPECTIONS LLC Houdek
51 Point View Ave Page 42 of 48
11. Kitchen and Built-in AppliancesInspection of kitchens typically includes (limited) operation and visual inspection of the following: wall, ceiling and floor; windows, skylights and doors;range/cooktop (basic functions, anti-tip); range hood (fan, lights, type); dishwasher; Cabinetry exterior and interior; door and drawer; Sink basincondition; supply valves; adequate trap configuration; functional water flow and drainage; disposal; Electrical switch operation; and outlet placement,grounding, and GFCI protection. Note: Appliances are operated at the discretion of the Inspector.
Styles & Materials
Cabinets:Solid WoodVeneer on MDF
Countertop Material:Laminate
Range:Gas
Range/Oven Brand:Jenn Air
Range Hood:Vents to exterior
Range Hood Brand:Jenn Air
Dishwasher:Present, Inspected
Dishwasher brand:Frigidair
Dishwasher Anti-siphon method:Air gap installed
Garbage Disposal brand:Kenmore
Refrigerator:Inspected
Refridgerator Brand:Frigidaire
Items
11.0 FloorsComments: Inspected
11.1 WallsComments: Inspected
11.2 CeilingsComments: Inspected
11.3 DoorsComments: Inspected
11.4 WindowsComments: Inspected
11.5 SkylightsComments: Inspected
11.6 Interior TrimComments: Inspected
11.7 Receptacles and SwitchesComments: Inspected
11.8 LightingComments: Inspected
11.9 CabinetsComments: Inspected
NW WASHINGTON HOME INSPECTIONS LLC Houdek
51 Point View Ave Page 43 of 48
11.10 Kitchen AppliancesComments: Inspected
11.11 RangeComments: Inspected
Kitchen cabinet door requiresadjustment.
11.9 (1)
Hot water dispenser mounted inthe kitchen sink is loose and requirestightening.
11.10 (1) Hot water dispenser
Front left burner of range would only light when back left burner lighted. The down-draft would only runwhen the left side burners were running. The range/oven combination appears original to the house and hasexceeded it's expected appliance life expectancy.
NW WASHINGTON HOME INSPECTIONS LLC Houdek
51 Point View Ave Page 44 of 48
11.12 Range HoodComments: Inspected
11.13 Garbage DisposalComments: Inspected
11.14 DishwasherComments: Inspected
The Kitchen and built-in appliances of the home were inspected and reported on with the above information. Any repair items mentioned in this reportshould be considered before purchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates tothe comments in this inspection report.
Recommend repair or replacement of range/oven by a licensed appliance technician.
11.11 (1) Kitchen Range
11.11 (2) Downdraft
NW WASHINGTON HOME INSPECTIONS LLC Houdek
51 Point View Ave Page 45 of 48
12. Laundry RoomIn addition to those items typically inspected as part of the interior, inspection of the laundry room includes examination of the following:dryerconnections and venting; room ventilation; and provision of proper clothes washer waste pipe.
Styles & Materials
Dryer Power:Electric
Dryer Vent:Smooth-bore metal (UL-approved)
Dryer 240-volt electrical receptacle:Installed
Items
12.0 FloorsComments: Inspected
12.1 WallsComments: Inspected
12.2 CeilingsComments: Inspected
12.3 DoorsComments: Inspected
12.4 WindowsComments: Inspected
12.5 SkylightsComments: Inspected
Laundry fan is not operational. Wall switch appears to have been removed. Fan removes moisture fromthe room as a result of using the washer/dryer.
Recommend repair/replace by a licensed electrician.
12.0 (1) 12.0 (2)
NW WASHINGTON HOME INSPECTIONS LLC Houdek
51 Point View Ave Page 46 of 48
12.6 Receptacles, Switches, ConnectionsComments: Inspected
12.7 LightingComments: Inspected
12.8 CabinetsComments: Inspected
12.9 Dryer VentingComments: Inspected
12.10 WasherComments: Inspected
12.11 DryerComments: Inspected
The laundry room of the home was inspected and reported on with the above information. Any repair items mentioned in this report should beconsidered before purchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates to thecomments in this inspection report.
NW WASHINGTON HOME INSPECTIONS LLC Houdek
51 Point View Ave Page 47 of 48
Recommended