Estimate Subsonic Flare Tip Pressure Drop With Graph Derived Correlation

Preview:

DESCRIPTION

flare

Citation preview

A place to share knowledge, lesson learnt...

HOME ARCHIVE LINK FREE MAGAZINES

FOLLOW ME

Enter your email address:

SUPPORT This Site

Hot Posts

Web Chem & Proc Tech

Monday, March 23, 2009

Display problem ? Click HERE

Recommended :- Tips on Succession in FREE Subscription- Subscribe FREE - Chemical Processing

Earlier post "Quick Estimate Flare Tip Pressure Drop" haspresented some clues in obtaining flare tip pressure drop for sonicand subsonic tip. Particularly for subsonic flare tip, a simple pressuredrop versus flow curve was presented. This graph may be used forquick estimation during conceptual stage so that it minimizeunnecessary time lost. However, the graph has limited to 0.5 - 40kPa with correspondent minimum and maximum flow. Someconceptual studies may have flaring capacity resultant pressure dropmore than 40 kPa, the graph may not be useful. In this post, a simpleformula will be presented in order to estimate pressure drop for anyflow rate for dedicated flare tip.

dP = 10 ^ (a x Log Q + b)

wheredP = tip pressure drop, kPaQ = Flow at standard condition, dm3/s (note 1)a & b = coefficient correspondent to tip size as list in following table

Tip Nom. Dia. (mm) a b

250 1.772663 -5.287376

400 1.92372 -6.671917

450 1.948852 -7.034009

500 1.945342 -7.329128

600 1.954552 -7.791866

Ads by Google Flare Gas Flare Drum Madcap Flare Ground Flare Flare Pants

Pipe Flow Calculator www.flowmaster.com

Analyse gas and liquid flows rates in pipingsystems

Flow Meters for Water www.awflowmeters.com/water

Cooling water applications & flow monitoring. 2"line size, 150 GPM

LFG Engineering www.haase-energietechnik.de

Landfill gas: extraction, disposal, powergeneration - CHP units

Coalescing & Conventional www.Temprite.com

Oil Separators for All Refrigerants includingCO2 & Ammonia

Useful Documents Related t(PRV) - Part 1Pressure Relief Valve (PRV) haoverpressure protection of presequipment. Regardless of vessdesigned in accordance to anye.g. ASME, JIS, BS, GB, etc,...

http://webwormcpt.blogspot.com/2009/03/estimate-subsonic-flare-tip-pressure.html

1 of 3 27/04/2011 13:39

Recommended Jobs

Chemical EngineerCikarang - PT Priuk Perkasa Abadi

Process Improvement SpecialistJakarta - EONCHEMICALSPUTRA, PT

Process EngineerJakarta - PT Bidar Timur

Sales Engineer for ProcessJakarta - PT. Yabestindo MitraUtama

Process Engineer (Code : PEG)South Jakarta - CITRANUSANTARA GEMILANG

www.indeed.com

750 1.968898 -8.24243

900 1.89152 -8.14936

1050 1.722666 -7.781574

1200 1.532001 -7.181798

Note 1 : The standard condition may be different from project to project (read more in"Avoid Confusion In "Standard" Flow Definition". Present standard definition is at101.325 kPa abs and 15 degC.

ExampleEstimate pressure drop of a subsonic flare tip with flow of 30,000 Sm3/h.

Q = 30,000 x 1000 / 3600 =8333.3 dm3/s @ Std

(i) A DN250 tip,dP = 10 ̂( 1.772663 x Log Q - 5.287376)dP = 10 ̂( 1.772663 x Log 8333.3 - 5.287376)dP = 46 kPa (outside curve)

(ii) A DN400 tip,dP = 10 ̂( 1.92372 x Log Q - 6.671917)dP = 10 ̂( 1.92372 x Log 8333.3 - 6.671917)dP = 7.4 kPa

(iii) A DN450 tip,dP = 10 ̂( 1.948852 x Log Q - 7.034009)dP = 10 ̂( 1.948852 x Log 8333.3 - 7.034009)dP = 4.0 kPa

(iv) A DN500 tip,dP = 10 ̂( 1.945342 x Log Q - 7.329128)dP = 10 ̂( 1.945342 x Log 8333.3 - 7.329128)dP = 2.0 kPa

You may compare results with chart in "Quick Estimate Flare Tip Pressure Drop".

Quick Estimate Flare Tip Pressure DropSeveral Criteria and Constraints for Flare Network - ProcessSeveral Criteria and Constraints for Flare Network - PipingProvide More than One Flare KOD in SERIESFlare Tip Quick Selection ChartFlare Smokeless Ringlemann Chart

Labels: Flare, FLARENET

Process engineer jobs

PROCESS ENGINEERWESTINDO ESA PERKASA, PT - Cibinonglocated at Cibinong, Bogor is looking for : PROCESSENGINEER Requirements : S1 degree withbackground... Jobs Keywords: PROCESSENGINEER Personal Notes...JobsDB Indonesia

more jobs »

Jobs by Indeed

Ads by Google Pipe Flow Rate Acute Gout Flare Iridium Flare Enclosed Flare Emergency Flare

http://webwormcpt.blogspot.com/2009/03/estimate-subsonic-flare-tip-pressure.html

2 of 3 27/04/2011 13:39

© 2008-2010 Chemical & Process Technology | Design by Webworm

posted by Webworm, 11:13 AM

Post a CommentLet us know your opinion !!! You can use some HTML tags, such as <b>, <i>, <a>

Subscribe to Post Comments [Atom]

Create a Link

<< Home

http://webwormcpt.blogspot.com/2009/03/estimate-subsonic-flare-tip-pressure.html

3 of 3 27/04/2011 13:39

Recommended