The O2PAK TM Chemical Oxygen Generator is a non-explosive, single-use oxygen source for use by armed forces within seconds of injury. The rugged and lightweight hand-held Oxygen Generator is small enough to fit in a standard military backpack. It has been designed to be activated within seconds, even in the most challenging or stressful situations, and delivers pure oxygen for extended duration, increasing chances of survival and recovery in cases of life-threatening injury. The O2PAK TM is particularly suitable for units operating in remote environments which are exposed to a high risk of serious injury – these include special operations forces, early entry and rapidly mobile land forces, airborne forces, marines, demining/ EOD engineers, peacekeeping forces, SWAT teams, search and rescue teams, medevac and disaster relief organizations.
Citation preview
CCC PROPRIETARY – Jan2013
CCC PROPRIETARY
FEB 2013
OXYGEN IN SECONDS EASE OF ACTUATION
OPERATES IN ANY POSITION
DESERT TO MOUNTAIN UP TO 40,000 FEET
COMPACT & RUGGED
NON EXPLOSIVE P26029
The O2PAK is an FDA approved handheld emergency oxygen solution for immediate use at the point of injury, under the most severe conditions and in the most remote locations until patient/casualty treatment and evacuation can be achieved.
CCC PROPRIETARY
FEB 2013
GRAB & GO SOLUTION ALWAYS READY
NO MAINTENANCE
NO REFILLING NEEDED NO NEED FOR BATTERIES
NO NEED FOR ELECTRICITY
SPECIAL OPS DEMINING MILITARY MASS CASUALTY
CCC PROPRIETARY
FEB 2013
CCC PROPRIETARY
FEB 2013
9.8 inches 25 cm
4 inches 10 cm
3 lbs 1.36 kg
TYPE Solid State Chemical – Single use Medically pure oxygen (USP99% - odorless - colorless) DURATION 22 minutes minimum guaranteed FLOW CHARACTERISTICS Flow rates 8-4 LPM for 22 minutes minimum Oxygen availability Within 4 seconds of actuation CAPACITY 90 liters minimum PRESSURE 3 psig max. during operation 30 psig max. during initial surge Pressure relief at approximately 25-35 psi GAS TEMPERATURE maximum 6° C above ambient ORIENTATION Works any position (vertical, horizontal) SHELF LIFE 48 months MAINTENANCE No battery, no electricity, no filling, no mixing P26029
CSTARS Testing University of Cincinnati College of Medicine
(laboratory conditions)
Flow rate/ duration is dependent on the surrounding ambient temperature, pressure, humidity & air circulation
CCC PROPRIETARY
FEB 2013
SAME GENERATOR AS USED ON BOEING PASSENGER AIRPLANES
Fundamental reaction: NaClO3 --> NaCl + 3/2 O2 Heat generating reaction: Na2O + 1/2 O2 --> Na2O2 + heat Chlorine absorption reaction: Na2O2 + Cl2 --> 2NaCl + O2
Oxygen is produced by chemical reaction when the activation pin is pulled, releasing a spring-powered striker that ignites the reactant. The reactant is sodium chlorate which produces heat in an exothermic reaction (internal temperature of the canister can reach over 300 °C degrees Celsius ). Once activated the production of oxygen cannot be stopped until the reactant is depleted. The heated sodium chlorate decomposes into sodium chloride (salt) and oxygen gas. In the presence of water, chlorine gas and hypochlorite ions are also produced. Disodium peroxide is used to scavenge the chlorine gas and hypochlorite ions.
MAT
T
CCC PROPRIETARY
FEB 2013
VIBRATION
PURITY - TEMPERATURES ALTITUDE CHAMBER
DROP TESTS
Extensive scientific R&D and testing (shock, vibration, temperature, purity, flow, pressure, humidity…) were done under a wide variety of operational conditions to prove safety and efficacy.
The O2PAK has been cleared by the FDA
O2PAK, Portable Oxygen Generator 510(K) number K120566
Regulation number 21 CFR 868.5440 Class II, Code CAW
The O2PAK is cleared for emergency use under the direction of trained medical military personnel in support for disaster relief, crisis response, wartime operations, deterrence and contingency operations, humanitarian relief operations or peacetime engagements.
CCC PROPRIETARY
FEB 2013
CCC PROPRIETARY
FEB 2013
ACTIVATION INSTRUCTIONS MARKED ON THE SIDE OF THE BAG
P26029
OXYGEN FLOWS WITHIN 4 SECONDS OF PULLING OUT BOTH PINS (SAFETY + ACTUATION)
1. OPEN COVER FLAP 2. CONNECT APPROVED CANNULA TO FLOW INDICATOR 3. PULL BOTH ACTIVATION PINS
4. CLOSE COVER FLAP 5. INDICATOR WILL SHOW FLOW 6. DO NOT PLACE THE DEVICE DIRECTLY ON THE PATIENT
FOR MORE INFORMATION, REFER TO SI-P26029
ONCE ACTIVATED, THE GENERATOR WILL INCREASINGLY GET HOT AND REMAIN HOT EVEN AFTER THE FLOW HAS STOPPED.
THE END COVERS MUST REMAIN SECURED IN CLOSED POSITION AT ALL TIMES. AVOID PROLONGED DIRECT CONTACT WITH THE SKIN (OVER 1 SECOND) AS POTENTIAL INJURY MAY OCCUR. NEVER PLACE THE DEVICE DIRECTLY ON THE PATIENT The O2PAK will become hot to the touch due to the exothermic reaction within the chemical oxygen generator (the internal temperature can reach up to 600 degrees Fahrenheit - 316 degrees Celsius) with a ‘hot spot’ up to 86°C / 187°F: temperature reached at, near, or past the end of flow.
CAUTION
CCC PROPRIETARY
FEB 2013
The O2PAK requires specific shipping boxes & handling procedures
Oxygen generators (O2PAK) are classified as hazardous Hazardous Materials Regulations HMR ; 49CFR 171-180
Hazard class: 5.1 oxidizer Packing group: II (if by air: CAO, Cargo Aircraft Only, 523)
Classification code: 03 UN number: 3356
The O2PAK cannot be carried on or shipped on passenger carrying aircraft P26029
CCC PROPRIETARY
FEB 2013
Where do I find the expiration date? On the label of the O2PAK
Does it make a difference which pin I pull out first? NO (but both pins need to be removed)
What happens if I remove only 1 pin? The flow will not start Both pins have been removed (2nd pin guarantees O2PAK will not actuate inadvertently)
Can pressure build up if the port is blocked? NO (there is a relief valve)
Can the O2PAK be used against toxic fumes or smoke? NO
Is it possible to stop the flow? NO (trying to putt a pin back will not stop the flow)
Is it possible to regulate the flow? NO the flow is pre-determined Can the O2PAK be used with ventilators (10-15LPM)? Not unless user combines multiple O2PAK to reach flow
Is it CE approved? Not yet
Will the O2PAK explode if a bullet goes through? NO, the O2PAK will not explode
What are the O2PAK storage temperatures? Optimal : +50°F to +95°F (+10°C to +35°C) Full range: -40°F to 158°F (-40°C to +70°C)
What are the O2PAK operating temperatures? Optimal : +35°F to +95°F (+2°C to 35°C) Full range: -4°F to 155°F (-20°C to 68°C)
Is a mask supplied with the O2PAK? NO, the O2PAK is an oxygen source only Patient interface: Salter Labs P/N 1600 Nasal Cannula or equivalent
P26029
CCC PROPRIETARY
FEB 2013
Combat Critical Care is a subsidiary of Pacific Precision Products (PPP), a privately owned corporation based out of Southern California. Founded in 1973, Pacific Precision Products has earned a strong reputation in the aerospace industry, with over 39 years expertise in the development, qualification and manufacturing of customized oxygen solutions for a large variety of platforms (Lockheed Martin, Boeing, Airbus, Gulfstream, Embraer, Bombardier, SpaceX etc….). Combat Critical Care is bringing a similar expertise to new markets for trained professionals within the military, search and rescue, first responder, homeland security, disaster relief and humanitarian efforts. With a highly skilled work force, it develops and manufactures customized solutions, working closely with its customers.