1/4
9/12/13 EMC SAN Architecture
www.datadisk.co.uk/html_docs/emc/emc_architecture.html
SAN Architecture
This document will be using the EMC symmetrix configuration. There are a number of EMC Symmetrix configurations but
they all use the same architecture as detailed below.
Front End Director Ports (SA-16b:1)
Front End Director (SA-16b)
Cache
Back End Director (DA-02b)
Back End Director Ports (DA-02b:c)
Disk Devices
Front End Director
A channel director (front end director) is a card that connects a host to the symmetrix, each card can have upto four ports.
Cache
Symmetrix cache memory buffers I/O transfers between the director channels and the storage devices. The cache is divide
up into regions to eliminate contension.
Back End Director
A disk director (back end director) transfers data from disk to cache. Each back-end director can have upto four interface
(C,D,E and F). Each back-end director interface can handle seven SCSI ids (0-6)
Disk Devices
The disk devices that are attached to the back-end directors could be either SCSI or FC-AL.
Interconnect
The direct matrix interconnect is a matrix of high speed connections to all componentswith bandwidth up to 64Gb/s
SAN Components
The are many components to a SAN Architecture. A host can connect to a SAN via direct connection or via a SAN
switch.
Host HBA Host bus adaptor c ards are used to ac cess SAN storage systems
SAN Cables
There are many types of cables and connectors:
Types: M ultimode (500m) and copper
Connectors: ST, SC (1Gb), LC (2Gb)
7/29/2019 EMC SAN Architecture
2/4
9/12/13 EMC SAN Architecture
www.datadisk.co.uk/html_docs/emc/emc_architecture.html
SAN Switches
The primary function of a switch is to provide a physical connec tion and logical routing of data
frames between the attached devices.
Support multiple protocols: Fibre channel, iSCSI, FCIP, iFCP
Type of switch: Workgroup, Directors
SAN Zoning
Zoning is used to partition a fibre channel switched fabric into subsets of logical devices. Each
zone contains a set of members that are permitted to access each other. Members are HBA's,
switch ports and SAN ports.
Types of zoning: hard, soft and mixed
Zone set sThis is a group of zones that relate to one another, only one zone set can be active at any one
time.
Storage arrays Storage array is were all the disk devices are located.
Volume access control
This is also know as LUN masking. The storage array maintains a database that contains a map of
the storage volumes and WWN's that are allowed to access it. The VCM database in a symmetrix
would contain the LUN masking information.
SAN Login
The below table documents the various proccesses that occur when a fibre channel device is connected to a SAN
Information/process FLOGI (fabric login) PLOGI (port login) PRLI (process login)
What is need ?
- Link initialization
- Cable
- HBA and driver
- Switch Port
- FLOGI
- Zoning
- Persistent binding
- Driver setting
- PLOGI
- Device masking (target)
- Device mapping (initiator)
- Driver setting (initiator)
What information is passed
- WWN- S_ID
- Protocol
- Class
- Zoning
- WWN- S_ID
- ULP
- Class
- BB Credit
- LUN
Who does the communication ? - N_port to F_port - N_port to N_port - ULP( scsi-3 to scsi-3)
where to find the information ?
Unix
- syslog
- switch utilites
Windows
- Event viewer
- Switch viewer
Unix
- Syslog
- Driver Ulitities
Windows
- Driver utilities
Unix
- Syslog
- Host based volume management
Windows
- Driver Utilities
- Host based volume management
- Device Manager
If any one of the above were to fail then the host will not be allowed to access the disks on the SAN.
VCM Database
7/29/2019 EMC SAN Architecture
3/4
9/12/13 EMC SAN Architecture
www.datadisk.co.uk/html_docs/emc/emc_architecture.html
The Symmetrix Volume Configuration Management (VCM) database stores access configurations that are used to gran
host access to logical devices in a Symmetrix storage array.
The VCM database resides on a special system resource logical device, referred to as the VCMDB device, on each
Symmetrix storage array.
Information stored in the VCM database includes, but is not limited to:
Host and storage World Wide Names
SID Lock and Volume Visibility settings
Native logical device data, such as the front-end directors and storage ports to which they are mapped
Masking operations performed on Symmetrix storage devices result in modifications to the VCM database in the
Symmetrix array. The VCM database can be backed up, restored, initialized and activated. The Symmetrix SDM Agent
must be running in order to perform VCM database operations (except deleting backup files).
Switches
There are three models of switchs M-series (Mcdata), B-series (Brocade) and the MDS-series (Cisco). Each of the switc
offer a web interface and a CLI. The following tasks can be set on most switches:
Configure network params
Configure fabric params (BB Credit, R_A_TOV, E_D_TOV, switch PID format, Domain ID)
Enable/Disable ports
Configure port speeds
Configure Zoning
BB
Credit
Configure the number of buffers that are available to attached devices for frame receipt default 16. Values range
1-16.
R_A_TOVResource allocation time out value. This works with the E_D_TOV to determine switch actions when presented
with an error condition
E_D_TOVError detect time out value. This timer is used to flag potential error condition when an expected response is
not received within the set time
The CLI commands can be viewed here for all switches, also a detailed view of zoning can be locatedhere.
Host HBA's
The table below outlines which card will work with a particular O/S
SolarisEmulex PCI (lputil)
Qlogic
HPUX PCI-X gigabit fibre channel and ethernet card
AIX FC6227/6228/6239 using IBM native drivers
Windows Emulex (HBAnyware or lputilnt)
Linux Emulex PCI (lputil)
The card configuration page can been seenhere
Clariion configuration
http://www.datadisk.co.uk/html_docs/emc/emc_hba_setup.htmlhttp://www.datadisk.co.uk/html_docs/emc/emc_zoning_arch.htmlhttp://www.datadisk.co.uk/html_docs/emc/emc_switch_cs.html7/29/2019 EMC SAN Architecture
4/4
9/12/13 EMC SAN Architecture
www.datadisk.co.uk/html_docs/emc/emc_architecture.html
The Clariion cheat sheet can be seen from this link
Symmetrix configuration
The Symmetrix cheat sheet can be seen from this link.
http://www.datadisk.co.uk/html_docs/emc/emc_symmetrix_cs.htmlhttp://www.datadisk.co.uk/html_docs/emc/emc_navisphere_cs.htmlRecommended