Electronic Paint-mixing Scales · Electronic Paint-mixing Scales. 2 General View of the Equipment...

Preview:

Citation preview

98648-014-21

98648-014-21

Installation Instructions

Sartorius PMA.Quality PMA7501, PMA7501-000…Electronic Paint-mixing Scales

2

General View of the Equipment

PMA7501

1 Displayandcontrolunit2 Qkey(On/Standby)3 Rkey:Upwards4 Skey:Downwards5 Ukey:Zero/Tare6 Ikey(TOGGLE) WiththePMA7501,youcantoggleto

twodecimalplaces–from0.05gto999.95g–ortogglebetween–“g”and“p”–partsperpound,dependingonthemenusettings

7 Kfactorkey(FORMULATION)forpaint-mixingapplications

8 ckey(Clear)and[REC]keyforpaint-mixingapplications

9 Lkey[ENTER]and[MEM]keyforpaint-mixingapplications

10 Display11 Weighingpan12 Interfaces

(here:D-Subconnector,9-contact)13 DCjackforconnectiontoACpower14 Column15 Joint

The following symbols are used in these instructions:

§ Indicatesrequiredsteps$ Indicatesstepsrequiredonlyunder

certainconditions> Describeswhathappensafteryouhave

performedaparticularstep– Indicatesaniteminalist! Indicatesahazard

1234567

89

11

12

14

10

13

15

3

Contents

GeneralViewoftheEquipmentPMA7501|PMA7501-000W. . . . . . . . 2

Contents . . . . . . . . . . . . . . . . . . . . . . . 3

IntendedUse . . . . . . . . . . . . . . . . . . . . 3

WarningsandSafetyPrecautions . . . . . 4

GettingStarted. . . . . . . . . . . . . . . . . . . 5

Operation. . . . . . . . . . . . . . . . . . . . . . . 7

Applications. . . . . . . . . . . . . . . . . . . . . 9

Calibration/Adjustment. . . . . . . . . . . . 12

MenuSettings . . . . . . . . . . . . . . . . . . 13

Troubleshooting. . . . . . . . . . . . . . . . . 18

CareandMaintenance. . . . . . . . . . . . 19

Recycling. . . . . . . . . . . . . . . . . . . . . . 20

Specifications. . . . . . . . . . . . . . . . . . . 21

InterfacePorts. . . . . . . . . . . . . . . . . . 22

Accessories. . . . . . . . . . . . . . . . . . . . . 23

USBPort(PC). . . . . . . . . . . . . . . . . . . 24

DeclarationofConformity. . . . . . . . . . 26

ThePMA7501hasbeenspeciallydesignedforuseinthepaint-mixingsector.Thisscalecanbeoperatedeitherusingthekeypadonthedisplayandcontrolunit(in“standalone”mode)orusingtheapplicationsoftware(e.g.,paintmanufacturers’paint-mixingapplica-tions)installedonyourPC.

Ifrequired,SartoriuscansupplyyouwithDOSorWindows®-baseddevicedriverstogenerateapplicationprograms.

Note:– Readtheinstallationandoperating

instructionscarefullybeforeconnectingthescaleandputtingitintooperation.

– TheapplicationexamplesandmenusettingsdescribedintheseinstallationinstructionsarenotvalidforPMA7501-000W.

Intended Use

4

Warnings and Safety Precautions

Thisscalemeetstheguidelinesandstandardsgoverningelectronicequipment,electromagneticcompatibilityandthestipulatedsafetystandards.Improperuseorhandlingcanresultinpropertydamageand/orpersonalinjury.Topreventdamagetotheequipment,readtheseoperatinginstructionsthoroughlybeforeusingyourscale.Keeptheseinstructionsinasafeplace.

– Iftheequipmentisnotusedinaccord-ancewiththeoperatinginstructions,productliabilitymaybeaffected.

– Donotexposethescaletoextremetemperatures,aggressivechemicalvapors,moisture,shocksorvibrations.

– Thedisplayedvaluescanbeaffectedwhensubjectedtoextremeelectromag-neticinfluence.Whenthenegativeinflu-encehassubsided,thescalewillagainbefullyoperational.

!Theequipmentmustbeusedindoorsonly.

!Thescalemaynotbeoperatedinhazard-ous/EXZoneareas.

!Toensuresafety,disconnecttheequip-mentfrompowerbeforeconnectingordisconnectingthecablesorelectronicperipheraldevices.

– Ifyouusecablespurchasedfromanothermanufacturer,checkthepinassignmentsinthecableagainstthosespecifiedbySartoriusbeforeconnectingthecabletoSartoriusequipment,anddisconnectanywiresthatareassigneddifferently.TheoperatorshallbesolelyresponsibleforanydamageorinjuriesthatoccurwhenusingcablesnotsuppliedbySartorius.

– Whenconnectingthescaletothepowersupply,thelawsvalidinyourcountrymustbeobserved.Ifyoushouldhaveanyquestions,pleasecontactyoursupplierorSartoriusCustomerServiceforinforma-tiononthelegalregulationsapplicableinyourcountry.Thescalemustbeinstalledbyacertifiedtechniciantoavoidforfei-tureofallclaimsunderthemanufacturer’swarranty.

!Ifyouseeanyindicationthatthescalecannotbeoperatedsafely(forexample,duetodamage),turnitoffandlockitinasecureplaceorotherwisepreventuseoftheequipmentforthetimebeing.Adheretotheaccidentpreventionregulationsandinformtheoperatorsaccordingly.

!AlwaysmakesuretheequipmentisdisconnectedfromACpowerbeforeperforminganyinstallation,cleaning,maintenanceorrepairworkonthescale.Toavoidforfeitureofallclaimsunderthemanufacturer’swarranty,allrepairandmaintenanceworkmustbeperformedbyauthorizedSartoriusservicetechnicians.

– Allothercablesconnectingtheweighingequipmentandperipheraldevices,aswellasthewiringinsidethedevices,arecasedinPVCmaterials.Chemicalsthatcorrodethesematerialsmustbekeptawayfromthesecables.

!Neveruseahammertoclosethelidofapaintcanwhileitisstillontheweighingpan.Otherwise,youwilldamagetheweighingsystem.

5

Getting Started

§ Removethescalefromitspackaging.

§ Afterunpackingthescale,checkitimmediatelyforanyvisibledamageasaresultofroughhandlingduringshipment.

Equipment Supplied – Scale– Weighingpan– Tableadapterwithcountry-specificmainscable– 2+protectiveplugs(inthecolumn)– ModelPMA7501-000Uonly:USBdatacable

Setting Up the Scale Chooseasuitableplacetosetupthescale.Avoid

exposuretodrafts,heat,moistureandvibration.MakesuretoreadtheinstructionscarefullybeforeconnectingthescaletoACpower.

!Observethesafetyinstructionsandwarningsinthismanual.

§ Placetheweighingpanonthescale.

°C

6

Connection to AC Power TheequipmentispoweredthroughtheACadapter

supplied

§ Inserttheright-angleplugintotheDCjack(13)onthescale

§ Connectthecountry-specificmainscabletotheadapter

§ PlugthemainscableintoanelectricalACpoweroutlet

!Observethesafetyinstructionsandwarningsinthismanual.

CheckthatthevoltageratingoftheACadaptermatchesthatofyourlocallinevoltage(mainssupply).Ifitdoesnotmatchyourlocalvoltageratingoriftheplugdesigndiffersfromyourlocalstandard,contactyourSartoriusofficeordealer.UseonlyoriginalSartoriusACadapters.TheuseofACadaptersfromothermanufacturers,eveniftheseunitshavearegisteredapprovalrat-ingfromanationaltestinglaboratory,requirestheapprovalofacertifiedtechnician.

7

Operation

Weighing with One Decimal PlacePlaceanemptypaintcanontheweighingpan.PressthetarekeyU(5).Thedisplayshows“0.0 g.”Pourinthefirstcomponent,andreadofftheweightassoonasthestabilitysymbolappears;inthiscase,“g.”Pourinadditionalcomponentsuntilthedesiredweightofyourformulaisreached.Removethefilledpaintcanfromtheweighingpan.

Neveruseahammertoclosethelidofapaintcanwhileitisstillontheweighingpan.Otherwise,youwilldamagetheweighingsystem.

TurnonthescaleusingtheQkey(2).

Afterthescalehasbeenturnedon,itwillautomati-callyrunaself-test.Attheendofthistest,0.0gisdisplayed.

Ifadifferentreadoutisdisplayed,zeroortarethescaleusingthetarekeyU(5).

8

Weighing with Two Decimal Places

Note:Toweighusingtwodecimalplaces,youmustfirstadaptthesettings(refertothechapterentitled“MenuSettings”)

PressthetogglekeyI(6).Thedisplayshows“0.00g.”

Placeanemptypaintcanontheweighingpan(11).

PressthetarekeyU(5).Thedisplayshows“0.00g.”

Pourinthefirstcomponent:205.50g.Readofftheweightassoonasthestabilitysymbolappears;inthiscase,“g.”

Pourinadditionalcomponentsuntilthedesiredweightofyourformulaisreached.Removethefilledpaintcanfromtheweighingpan.

Important Note:Ifyoutarethescale,andthenpressthetogglekeyI(6)totoggletotheseconddecimalplacewitharesolutionof0.05g,youcancontinueweighingwithtwodecimalplacesupto999.95g.Forweightsexceeding999.95g,onlyonedecimalplacewillbedisplayed.

Neveruseahammertoclosethelidofapaintcanwhileitisstillontheweighingpan.Otherwise,youwilldamagetheweighingsystem

9

Applications

Formulation Mode (Calculation by a Factor)Thismodeenablesyoutoweighinamountsthataresmallerorlargerthanthatofyourbasicformulaforaspecificpaintcolor(e.g.,250mlofa1-lformula).Youcanselectvariousfactors(amounts)bypressingtheKformulationkey(7):0.25 0.5 0.75 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0.

Bypressingthe Rkey(3):upwardsor Skey(4):downwards,youcanalterthevalue – in0.1increments,asoffactor1.0or – 0.01increments,fromfactor0.25to1.0.

Important Note:Theflashingarrownonthedisplaymeansthattheweightshownisnotverifiedforuseinlegalmetrology(notlegalfortrade).

Example:Asyoupourinthecomponentsofyourformula,theweightisdisplayedin“g.”Let’ssupposeyouwanttoweighonly250mlofabasicformulathatisforatotalamountof1L.Withtherecalculationmode,youdonotneedtomanuallyrecalculatetheindividualcomponents.Thebasicformulafor1literis:

250g 1stcomponent + 250g 2ndcomponent + 500g 3rdcomponent Total: 1000 g

1. Placetheemptypaintcanontheweighingpanandtare(zerothedisplay).

2. PresstheKformulationkey(7)severaltimestoselecttheconversionfactor“.25”usedinthisexample.

10

Wehavecometotheendofourexample.Accordingtothedisplay,exactly1,000gwaspouredin,butthepaintcanactuallycontainsonly250gbyweightaccordingtothefactoryouselected,.25.Followthesameprocedureforanyotherconversionfactorortoconverta1-gallonformulaintoquarts.

Weighing Using the Recalculation Mode Let’ssupposethatyoupouredintoomuchofonecolorcomponentforagivenformula(e.g.,oneconsistingof4components).Inaddition,let’sassumethatyoupreviouslypouredinalloftheotheramountsexactlyaccordingtoeachofthevaluesyouenteredandstoredbypressingtheLkey[MEM](9).PresstheSkey(4)tostarttherecalculationprogram.“C”willbeginflashingonthedisplay.Tocorrecttheweightdisplayedtothesamevalueyouenteredforthegivenformula,eitherscrollupwardsusingtheRkey(3),ordownwardsusingtheSkey(4).WhenyouthenpresstheLkey[MEM](9),thescalewillautomaticallycalculateanddisplaytheamountsofpaintin“g”toaddforeachoftheothercomponentsthatyoualreadypouredin.Thismodethusensuresthatthetotalresultofyourformulaforthesecomponentswillbecorrect.Afterpouringintheseamounts,youcancontinuetoaddtheremainingcomponentsofyourformula.

Important Note:Youcancorrectanincorrectamountanynumberoftimes.However,thetotal(liter)quantityinthepaintcanwillincreaseeachtimeyoucorrectacomponent.Therefore,presstheckey(8)tocheckhowmuchthetotalquantity(inliters)willbe.(“C”=correctionfactor)

Thearrowninthedisplaymeansthattheweightshownisnotverifiedforuseinlegalmetrology(notlegalfortrade).

3. “.25”isdisplayednexttotheweight

4. Slowlypourinthefirstcomponent,“250g”untilthedisplayshows“250g.”

5. Pourinthesecondcomponent,“250 g”untilthedisplayshows“500 g.”

6. Pourinthelastcomponent,“500g”until“1000 g”isdisplayed.

11

3.Pourinthefirstcomponent.+50.0g

2.PresstheUkey(5)0.0g

Example (cumulative):

1.Placeanemptypaintcanontheweighingpan(11).+118.0g

4.PresstheLkey[MEM](9).STO01

5.Pourinthe2ndcomponent.+110.0g

6.PresstheLkey[MEM](9).STO02

7.Pourinthe3rdcomponent.+203.0gOops!Youpouredintoomuch!Thecorrectweightfortheformulais200.0g.

8.Presstheykey(4)tostarttherecalculationmode.A“C”=correctflashesonthedisplay

9.Presstheykey(4)severaltimestocorrectthevalueto:+200.0g

10.PresstheLkey[MEM](9)COR01

11.1.Addthefirstcomponent.“C1”isdisplayed–1.7g

12.Pourinpaintuntil0.0gisdisplayed.0.0g

13.PresstheLkey[MEM](9)COR02

14.Addthesecondcompo-nent.“C2”isdisplayed.–2.0g

15.Pourinpaintuntilthevalue0.0gisobtained0.0g

16.PresstheLkey[MEM].Thescalewillautomaticallyreturntotheformulationprogram“C”disappears.+200.0g

17.Tocheckthetotalweight,presstheckey(8)[REC].“C”=Correctionfactor,inthisexample1.03.(Totalformulaweight+correctionfactor=totalweight)

18.Addthefourthcomponent+1000.0gWehavecometotheendofourexample.

12

Calibration/Adjustment

Youcancalibrate/adjustthescalebypressingthetarekeyU(5).Todoso,menucode151mustbeselected.

Calibrationweight:5,000g;accuracy:+0.075g.

AfterconnectiontoACpowerandbeforeeachcalibration/adjustment,allowthescaletowarmupforapprox.30min.

HolddownthetarekeyU(5).for2sec.When5000isdisplayed,releasethekey.

Centerthecalibrationweightontheweighingpan(11).Calibration/adjustmentisperformedautomatically.Aftercalibrationandadjustment,removetheweight.

13

Menu Settings

Navigating the SETUP Menu Example: MenuItem:Adaptationtoambientconditions

§HolddowntheLkey[ENTER]forapprox.2sec.“SETUP”willappearonthedisplay(Level1).

§UsetheRSkeystoselectthedesiredmenuiteminthefirstlevel.

§ PresstheLkey[ENTER]toselectthesecondlevel(Level2).

§UsetheRSkeystoselectthedesiredmenuiteminthesecondlevel.

§ PresstheLkey[ENTER]toselectthethirdlevel(Level3).Themenuitemsinthethirdlevel(Level3)willbedisplayed

§UsetheRSkeystoselectthedesiredmenuitem.

§ PresstheLkey[ENTER]toselectthefourthlevel(Level4).

§ Callupthemenuitemdesiredinthefourthlevel.UsetheRSkeystoselectthedesiredmenuitem.

(Wehavecometotheendofourexample.)

§ PresstheLkey[ENTER].“o”willappear;thedesiredsettingisdefined.

§ Presstheckey(Clear)severaltimestoexitthemenu.

Note:Toobtainadetailedlistofthemenucodes,pleaseaskyournearestSartoriusoffice.

14

Important Menu Settings§ HolddowntheLkey[ENTER]forapprox.2sec.“SETUP”willappearonthedisplay(Level1). Level1 SETUP

Language Settings Level1 Level2

LANGUAGE § PresstheRkeytoselect“LANGUAGE” § PresstheLkeypress[ENTER] o GERMAN § PresstheRSkeystoselectalanguage ENGLISH § PresstheLkey[ENTER]:“o”appears; FRENCH thedesiredsettingisdefined. ITALIAN § Presstheckey(Clear)severaltimesto etc. exitthemenu.

Default Setting: Standard (0.1) or PolyRange (0.05 g/0.1 g); Grams, PT or LB. Defaultfortheseparametersaredefinedunder“SETUP-SCALE-UNIT”and

“SETUP-SCALE-DECIMALS”: Level1 Level2 Level3 Level4

SETUP § PresstheLkey:[ENTER] SCALE § PresstheLkey:[ENTER] UNIT § RSkeys:select“DECIMALS” § PresstheLkey:[ENTER] GRAMS § RSkeys:select“STANDARD” o PT./LB. § PresstheLkey[ENTER];“o”appears: DECIMALS thenewcodehasbeenset. o STANDARD § Presstheckey(Clear),severaltimes POLYRANGE toexitthemenu.

I – Activating the Toggle Key AfterthetogglekeyI(6),hasbeenactivated,youcanindividuallyconfigureitwitheither1or2

decimalplaces,aswellaswithgramsorPT./LB.(seebelow).Onceactivated,pressingthetogglekeytogglesthedisplaybetweenunitsanddecimalplaces.

Level1 Level2 Level3 Level4

SETUP § PresstheLkey[ENTER] APPLICATION § RSkeys:select“APPLICATION” § Lkey:press[ENTER] TOGGLE § RSkeys:select“TOGGLE” OFF § Lkey:[ENTER], o ON RSkeys:select“ON”. § PresstheLkey[ENTER];“o”appears; thedesiredsettingisdefined. § Presstheckey(Clear)severaltimesto exitthemenu.

15

Assigning a Function to the I Toggle Key PressingthetogglekeyI (6)togglesthescalebetweenthedefaultsetting(seepreviouspage)and

thesettingsconfiguredunder“SETUP-SCALE-UNIT”and“SETUP-SCALE-DECIMALS” Level1 Level2 Level3 Level4

SETUP § PresstheLkey:[ENTER] APPLICATION § RSkeys:select“APPLICATION” UNIT § Lkey[ENTER]:selecttheSkey “UNIT,”pressLkey[ENTER]. PT./LB. § RSkeys:select“GRAMS” o GRAMS § PresstheLkey[ENTER];“o”appears: thedesiredsettingisdefined. DECIMALS § RSkeys,select“DECIMALS” STANDARD § PresstheLkey,selectsetting o POLYRANGE § PresstheLkey[ENTER];“o”appears Presstheckey(Clear)toexitthemenu.

Activating the “LOCK” Function Byactivatingthe“LOCK”function,youcanprotectthescalefromunauthorizeduse.Whenthe

scaleisconnectedtoaPC,thetwodevicesareinconstantcommunication.Ifthe“LOCK”functionisactivatedunder“EXTRAS,”anddatatransmissiontothePCisinterrupted,thelocksymbolwillbedisplayed.Thescalewillautomaticallybelocked,preventingfurtherweighingoperations.

Level1 Level2 Level3 Level4

SETUP § PresstheLkey[ENTER] EXTRAS § RSkeys:select“EXTRAS” § PresstheLkey[ENTER] LOCK § RSkeys:select“LOCK” § PresstheLkey[ENTER] OFF § Select“ON”usingtheRSkeys o ON ConfirmwiththeLkey § Presstheckey(Clear)severaltimes toexitthemenu.

Entering a Password Inadditiontoactivatingthe“LOCK”function,theusermayalsoenterapassword. Shouldtheuserwishtodeactivatethe“LOCK”functionbypressingthe“OFF”key,hemustfirst

enterthevalidpassword.Thepasswordiscomprisedofa6-characternumericcode.UsetheRSkeystocallupnumbers(0to9).Sixdashes(------)willappearinthedisplay.Thefirstdashwillblinkinthedisplay.Selectanumber(0to9)usingtheRSkeys,presstheLkey[ENTER]tosavethenumber.Theseconddashwillstarttoblink.Repeattheaforementionedprocess.Shouldyouwishtoassignablankspacetooneofthesixcharacters,simplypresstheLkey[ENTER]whenthedashbeginstoblink.Onceall6charactershavebeenentered,presstheLkey[ENTER]toconfirm.

16

Note: Keeparecordofthenumericcodeinasafeplace.Thescalecanonlybeaccessedbyenteringthe

correctcode. Level1 Level2 Level3 Level4

INPUT § RSkeys:select“INPUT” PASSWORD § PresstheLkey[ENTER] § PresstheLkey[ENTER] PW.NEW § RSkeys:select“PW.NEW” -------- § Enterthenumericcode:presstheLkey [ENTER]. § Presstheckey(Clear)severaltimes toexitthemenu.

Changing the Password Shouldyouwishtochangethepassword,youmustfirstcorrectlyentertheoldpasswordunder

“Password.”“PW.OLD”willbedisplayed.Followingthecorrectinput,“PW.NEW”willautomaticallyappear.Youcannowenteranewpassword,orconfirmeachblinkingdashbypressingtheLkey[ENTER].Blankspacesarethendisplayed.

Note: Theoldpasswordcanbedeletedbyentering6blankspaces.Thescaleisthusresettoitsoriginal

state;i.e.,thescaleisnotpassword-protected. Level1 Level2 Level3 Level4

INPUT § RSkeys:select“INPUT” PASSWORD § PresstheLkey[ENTER] PW.OLD § PresstheLkey[ENTER] -------- § Entertheoldpassword“PW.OLD” PW.NEW § “PW.NEW”willappearwhentheold passwordiscorrectlyentered -------- § Enterthenumericcode:presstheLkey [ENTER] § Presstheckey(Clear):resetthemenu.

17

Setting “TEXTS” in the Display, “LONG” or “SHORT” Eithershortorlongdisplaypromptsforoperatorguidancecanbeshown. Level1 Level2 Level3 Level4

SETUP § PresstheLkey[ENTER] EXTRAS § PresstheRSkeystoselect“EXTRAS” § PresstheLkey[ENTER] TEXTS § PresstheRSkeystoselect“TEXTS” § PresstheLkey[ENTER] LONG § PresstheRSkeystoselect“SHORT,” o SHORT confirmbypressingtheLkey. § Presstheckey(Clear)severaltimes toexitthemenu

Resetting the Scale: “RESET” Ifnecessary,youcanresetthescaletofactorysettings.

Note:Ifapasswordwasactivated,thecorrectpasswordmustfirstbeentered.

Level1 Level2 Level3 Level4

SETUP § PresstheLkey[ENTER] RESET § PresstheRSkeystoselect“RESET” § PresstheLkey[ENTER] MENU § PresstheRSkeystoselect“MENU” § PresstheLkey[ENTER] YES § UsetheRSkeystoselect“YES” o NO § PresstheLkey[ENTER];“o”willappear: thenewcodeisset § Presstheckey(Clear)severaltimes toexitthemenu

Setting Codes Underthesetting“CODES,”themenuitemsaredisplayedincode1.1.1.1. Level1 Level2 Level3 Level4

LANGUAGE § PresstheRkeytoselect“LANGUAGE” § PresstheLkey[ENTER] GERMAN § PresstheRSkeystoselect“CODES” etc. § PresstheLkey[ENTER];“o”willappear: thenewcodeisset o CODES § Presstheckey(Clear)severaltimes toexitthemenu.

Note: Toobtainadetailedlistofthemenucodes,pleaseaskyournearestSartoriusoffice.

18

Troubleshooting

Problem Cause SolutionNosegmentsappear –NoACpoweravailable –ChecktheACpowersupplyontheweightdisplayWeightdisplayshows –Theweighingpanis –Positiontheweighingpan“Low” isnotinplaceWeightdisplayshows –Theloadonthepan –Unloadthescale“High” exceedsthescale’scapacityTheweightreadout –Unstableambientconditions – Setupthescaleinanotherareachangesconstantly –Toomuchvibrationor –Accessthemenutoselect thescaleisexposedtodraft theappropriatecodetoadapt

thescaletotheparticularweighingenvironment(referto“MenuSettings”)

Theweightreadout –Thepaintcomponentdoes –Tarepriortoweighingisobviouslywrong nothaveastableweight –Thescalewasnottared beforeweighingNoweightvalueis –Datacommunicationbetween –Accessthemenusettingstoshownandthelock scaleandPChasbeen deactivatethe“Lock”functionsymbolisactive interruptedandthe“Lock” –Checktheconnection functionisactive

19

Care and Maintenance

Cleaning!Donotusecaustics,concentratedacids

orpurealcohol.

!Makesurethatnoliquidentersthescalehousing

$ Cleanthescaleusingeitherapaintbrushoradry,softandlint-freecloth.

Storage and Shipping Conditions$ Toensuresafeshipment,yourscalehas

beenpackagedusingenvironmentallyfriendlymaterials.Youshouldretainthesematerialsincaseyouneedtopackageyourscaleforstorageorreturnshipment.

$ Storagetemperature:–20°Cto+75°C$ Permissiblemoisturelevelforstorageof

thepackagedscale:90%max.$ Readandfollowtheinstructionsgivenin

thesectionentitled“SafetyInspection.”

Safety Inspection SafeoperationofthePMAisnolonger

ensuredwhen:– ThereisvisibledamagetotheACadapt-

er/powersupply– TheACadapter/powersupplynolonger

functionsproperly– TheACadapter/powersupplyhasbeen

storedforarelativelylongperiodunderunfavorableconditions

– Theequipmenthasbeenexposedtoroughhandlingduringshipment

§Observethewarningandsafetyinformation

Inthiscase,notifyyournearestSartoriusServiceCenterortheInternationalTech-nicalSupportUnitbasedinGoettingen,Germany.Maintenanceandrepairworkmayonlybeperformedbyservicetechni-cianswhoareauthorizedbySartoriusandwho

– Haveaccesstotherequiredserviceandmaintenancemanuals,or

– Haveattendedtherelevantservicetrainingcourses

!Thesealsaffixedtothisequipmentindicatethatonlyauthorizedservicetechniciansareallowedtoopentheequipmentandperformmaintenanceworksothatsafeandtrouble-freeopera-tionoftheequipmentisensuredandthewarrantyremainsineffect.

20

Recycling

Thepackagingismadefromenvironmentally-friendlymaterialsthatcanbeusedassecondaryrawmaterials.Ifyounolongerneedthispackaging,bringittoyourlocalrecyclingandwaste

disposalfacilityaccordingtotheregula-tionsapplicableinyourcountry.InGermany,youcandisposeofthismaterialusingtheVfWdualsystem(contractnumberD-59101-2009-1129).Theequipment,includingaccessoriesandbatteries,mustnotbedisposedofingeneralhouseholdwaste,andmustberecycledsimilartoelectricalandelectronicdevices.Forfurtherinformationaboutdisposalandrecyclingoptions,pleasecontactyourlocalservicestaff.ThepartnerslistedonthefollowingwebsitecanbeusedfordisposalswithintheEU:

1) Gotohttp://www.sartorius.com.

2) Selectthesummaryunder“Service.”

3) Thenselect“InformationonDisposal.”

4) AddressesforlocalSartoriusdisposalcontactscanbefoundinthePDFfilesgivenonthiswebpage.

h Sartoriuswillnottakebackequipmentcontaminatedwithhazardousmaterials(ABCconta-mination)eitherforrepairordisposal.

Insert heading: “Service Address for Disposal” Pleaserefertoourwebsite(www.sartorius.com)orcontacttheSartoriusServiceDepartmentformoredetailedinformationregardingrepairserviceaddressesorthedisposalofyourdevice.

21

Specifications

Model PMA 7501, PMA7501-000W, PMA7501-000V2 PMA7501-000UWeighingrange g 999.95/7500Readability g 0.05/0.1Tarerange(subtractive) g –999.95/–7500Max.linearity g < ±0.2Stabilityrange digit 0.25to4Moisture-proofrating F Non-condensingAllowableambientoperatingtemperaturerange °C 0to+40Weighingpan dmm 233Scalehousing(W+D+H) mm 233+329+391Netweight,approx. kg 3.3Calibrationweight kg 5,classF2orbetterPowerconsumption VA Average:8;maximum:16Interface RS-232C USB(virtualserial

interface)– Format 7-bitASCII,1startbit, 7-bitASCII,1startbit, 1or2stopbits 1or2stopbits– Parity Even,oddornoparity Even,oddornoparity– Transmissionrates 1200to38,400bit/s 1200to38,400bit/s– Handshakemode Softwareorhardware Softwareorhardware

Formoreinformation,seethesectionentitled“USBPort”

22

Interfaces

9-contact interface port USB Typ B

Pin Assignment Pin Name Description Pin2:(RXD)ReceiveData 1 VCC +5V Pin3:(TXD)TransmitData 2 D– Data– Pin4:(DTR)DataTerminalReady 3 D+ Data+ Pin5:(GND)Ground 4 GND Ground Pin6:BPIbridge Pin8:(CTS)CleartoSend

1 2

4 3

23

Accessories

In-usedustcover YDC01PMA

RS-232datacable(SBI) (2m) YCC01-0027M2RS-232datacable(BPI) (2m) YCC01-0028M2RS-232datacable(BPI) (20m) YCC01-0028M20USB/RS-232datacable(SBI) (1.80m) YCO12USB/RS-232datacable(BPI) (1.80m) YCO13USBdıatacable YCC01-0040M3

ACadapter – forallcountriesexceptIndia 6971991 – forIndiaonly 6971983

+country-specificcable

24

USB Port (PC)

PurposeAnyPMA7501-000UcanbeconnectedtoaPCequippedwithaUSBport.Avirtualserialinterface(virtualCOMport)issetupasadevicetypeattheUSBport.Thisvirtualserialinterfaceisidentifiedundoperatedbytheapplicationprogram.TheprotocolsxBPIandSBIcanbetransmittedviatheUSBport.

System Requirements–Computer(PC)withWindows98SE®,WindowsME®,Windows2000®,WindowsXP®,

WindowsVista®orWindows7®–AvailableUSBportonthePC–USBcable

Connecting the Balance via USB

!ThecurrentUSBportforthecomputerisestablishedwhenthesoftwaredriverisbeinginstalled.Thedrivermustbere-installedeverytimeyouwishtochangetheport.Therefore,chooseoneUSBportthatcanpermanentlyorregularlybeusedtocon-nectthebalance.

–Switchoffthebalance.–Unplugthebalancefromthemains.–ConnecttheUSBcabletothebalanceandtotheUSBportonthecomputer.–Plugthebalanceintothemainsagainandswitchiton.–WindowsdetectsthedeviceconnectedtotheUSBport.

Ifthedeviceisbeingconnectedforthefirsttime,theWindowsInstallationWizardwillrun.

Installing Software Drivers–RuntheInstallationWizardforthedriver.–Followtheinstructionsthatappear.–Tocompletetheinstallation,clickonFinish.–Thevirtualinterfaceisnowreadyforoperation.

Windows®usuallyaddsthevirtualportinthepositionfollowingyourhighest-numberedCOMport.

Example:ForaPCwithupto4COMports,thenewvirtualportwouldthenbeCOM5(seeDeviceManager).

25

Installation Guides for Windows XP®, Windows Vista® and Windows 7®

Changing the Port NumberIfyouusetheUSBinterfacewithaprogramthatlimitsthenumberofCOMportdesignations(e.g.,onlyCOM1,2,3,4),youmayhavetoassignoneoftheseportnumberstothenewvirtualport.

–OpenthesettingfortheUSBserialportintheWindows®ControlPanel:–START>MyComputer>ControlPanel–System>Hardware>DeviceManager

–OpentheConnectionssubmenu.–Double-clickonUSBSerialPort.–SelectPortSettings>Advanced.

Changing Latency Time–OpenthesettingsfortheUSBserialport,followingtheaboveinstructions.–Forafasterrateofcommunication,changethesettingforthelatencytimerto1msec.

Plug & Play Mode in Autoprint (SBI)–OpenthesettingsfortheUSBserialport,followingtheaboveinstructions.–StopthePlug&Playmodefromrunning.

Uninstalling the DriverThesoftwaredriverfortheUSBconnectioncanbeuninstalledwiththeWindows®Uninstaller.

26

Printed in the EU on paper bleached without chlorine. | WPublication No.: WPM6042-e160406

04 | 2016Last updated:

The information and figures contained in these instructions correspond to the version date specified below.Sartorius reserves the right to make changes to the technology, features, specifications and design of the equipment without notice.Masculine or feminine forms are used to facilitate legibility in these instructions and always simultaneously denote the other gender as well.

Copyright notice:This instruction manual, including all of its components, is protected by copyright.Any use beyond the limits of the copyright law is not permitted without our approval.This applies in particular to reprinting, translation and editing irrespective of the type of media used.

© Sartorius Germany

Sartorius Lab Instruments GmbH & Co. KGWeender Landstrasse 94–10837075 Goettingen, Germany

Phone: +49.551.308.0Fax: +49.551.308.3289www.sartorius.com

Recommended