Equipment and Software Setup

v1.2

Edwards EV1000 Clinical Platform

EV1000 Clinical Platform

Intro

Intro

The EV1000 clinical platform from Edwards

Lifesciences presents the physiologic status of the

patient in an entirely new, intuitive and meaningful way.

Designed in collaboration with and validated by

clinicians, the EV1000 clinical platform offers you

scalability and adaptability in both the OR and ICU.

Experience the EV1000 clinical platform and the choice

of the parameters you want, how you want to view

them — and bring clarity to every moment.

EV1000 Clinical Platform

Monitoring Configurations

FloTrac Sensor

• The FloTrac sensor can

be used independently

to monitor:

– CO / CI

– SV / SVI

– SVV

• When used with the

TruWave transducer,

CVP - SVR can be

continuously displayed

EV1000 Clinical Platform

TruWave Transducer

FloTrac Sensor

PreSep or PediaSat Oximetry Catheter

• PreSep or PediaSat

oximetry catheters can

be used independently

with EV1000 clinical

platform to monitor

ScvO2 continuously

EV1000 Clinical Platform

OM Module PreSep

Catheter

FloTrac Sensor and

PreSep Oximetry Catheter

• The FloTrac sensor

and PreSep oximetry

catheter can be used

together

EV1000 Clinical Platform

FloTrac Sensor

OM Module

PreSep

Catheter

VolumeView Set

• The VolumeView set:

– Intermittent TPTD

• GEDI

• EVLWI

• PVPI

• iCO/iCI

• iSV/iSVI

– Continuous Calibrated

• CO / CI

• SV / SVI

• SVV

EV1000 Clinical Platform

VolumeView Sensor

TruWave

Transducer

VolumeView

Thermistor

Manifold

VolumeView

Femoral

Artery

Catheter

VolumeView Set & PreSep Catheter

• The VolumeView set can

be used together with the

PreSep oximetry catheter

EV1000 Clinical Platform

OM Module

PreSep

Catheter

VolumeView Sensor

VolumeView

Femoral Arterial

Catheter

TruWave Transducer

VolumeView

Thermistor

Manifold

EV1000 Clinical Platform

Hardware Setup

EV1000 Clinical Platform

EV1000 Monitor

EV1000 Databox

• EV1000 monitor is a medical

grade computer used to display

measured and derived

parameters from the FloTrac

sensor or Volume View sensor

as well as PreSep oximetry

catheter

EV1000 Monitor

EV1000 Monitor (Front)

EV1000 Monitor (Base)

EV1000 Monitor

• Monitor On/Off

EV1000 Monitor

• Power

Supply

Connection

EV1000 Monitor

• Ethernet Connection

Communication between

Monitor and Databox

EV1000 Databox

Databox (Front)

Databox (back)

Databox (bottom)

EV1000 Databox (Front)

Sliding back plate to mount

four (4) sensors

Power / communication

indicator LED’s

EV1000 Databox (Back)

Optical Module

Connection Pressure Cable

Connection

Temperature Cable

Connection

EV1000 Databox (Back)

• Green FloTrac sensor or

VolumeView sensor connection to

EV1000 databox pressure cable with

Green Connection

• White TruWave transducer

connection to Blue EV1000 databox

pressure cable

• PX1800 cable connected to

appropriate bedside monitor CVP

pressure channel then to blue

EV1000 databox pressure cable

EV1000 Clinical Platform

TruWave Transducer

FloTrac Sensor

EV1000 Databox (Base)

Power Cable

ConnectionEthernet Cable

Connection

EV1000 Monitor (Power)

AC

EV1000 Monitor (Communications)

Edwards Ethernet Cable

EV1000 Clinical Platform

Software Setup

Start Up Screen

Patient Data Screen

Enter Patient ID

Enter Patient’s Height cm / inches

Enter Patient’s Weight lbs / Kg

Enter Patient’s Age

Enter Patient’s Gender

Confirm Patient Data and Click Home

Navigation Bar

Quick Scroll

Screen Selection

Clinical Action

Settings

Screen capture ―Snap Shot‖

Alarm Silence (2 minute)

Quick Scroll

Display Screen Selection

Select Display Screen

Select Number Parameters per Screen

Trend Line

Trend Line Setup

Numeric Value Screen

Numeric Value Screen Setup

Globe Screen

Cockpit Screen

Physiology Screen

Physio-relationship Screen

EV1000 Clinical Platform

Parameter Setup

Selecting Displayed Parameter

Touch outside the globe and

select desired parameter

Adjusting Targets and AlarmsUp / Down Arrows

Adjusting Targets and AlarmsUp / Down Arrows

Adjusting Target ValueNumeric Keypad

Adjusting Target ValueDisplay : Cockpit Screen

Adjusting Target ValueDisplay : Globes

Adjusting Target ValueDisplay : Trend Screen

Adjusting Target ValueDisplay : Large Numbers

Audible Alarms On / Off (Permanent)

Target Ranges On / OffRange Off / High – Low Alarms On

EV1000 Clinical Platform

Settings

Settings

Patient Data

Monitor Settings

Parameter Settings

Parameter SettingsAlarm / Targets

Parameter SettingsAdjust Scales

Parameter SettingsTime Intervals / Averaging

Data Download

Demo Mode

Demo Mode

EngineeringEdwards technical support only

Help

EV1000 Clinical Platform

Clinical Actions

Clinical Actions

Zero and Waveform

Zero FloTrac Sensor or

VolumeView Sensor

Transducer Not Connected

Click ― – 0 – ― to Zero

Zero Complete

CO Parameters Displayed

CO parameters

displayed after the

FloTrac sensor is

zeroed and the

VolumeView

sensor is

calibrated against

TPTD

Clinical Actions

Transpulmonary

Thermodilution

(TPTD)

TPTD

TPTD

TPTD

Select Injectate Bolus Volume

TPTDLung Resection Selection

TPTDCatheter Temperature Probe Connected?

TPTDThermistor Manifold

TPTDStart

• Attach lure lock Syringe with

cold Normal Saline bolus

• Wait for ―inject‖ on monitor

• Inject in one smooth motion

• Do not start and stop

• Remove syringe

• Repeat, max 6 times

TPTDBolus

TPTDAlert Bolus : Irregular Injection

TPTDReview Boluses

TPTDEdit Boluses

TPTDAccept Edited Bolus = Calibrate CCO

TPTDAverage of Edited Bolus

TPTDReview Physiology Screen

• Volumetric

– GEDV

– GEF

– EVLW

– PVPI

• Continuous

– CO / CI

– SV / SVI

– SVR / SVRI

– SVV

EVLW

EVLWI of above 7 mL / kg

display on graphic and

progressively fill the lung

as it increases

Clinical Actions

Oximetry Calibration

Oximetry Calibration

Default Display ScvO2

Oximetry Calibration

Connect Optical Module

Oximetry Calibration

Optical Module Initializing

In Vitro Calibration

In Vitro Calibration

Hemoglobin or Hematocrit

In Vitro Calibration

Enter H&H

In Vitro Calibration

H&H Calibrating

H&H Update Finished

Press ―Start‖

In Vitro Calibration

Calibration in Progress

In Vitro Calibration

ScvO2 Displayed

In Vivo Calibration

In Vivo Calibration

Baseline Setup in Progress

In Vivo Calibration

Ready Equipment then ―Draw‖

In Vivo Calibration

Enter ScvO2 and H&H

In Vivo Calibration

Enter Hemoglobin or Hematocrit

In Vivo Calibration

Enter ScvO2

In Vivo Calibration

Confirm Data and Press ―Calibrate‖

In Vivo Calibration

Calibration 25 Second Update

In Vivo Calibration

Calibrated ScvO2 Value Displayed

Recall Optical Module Data

Recall Optical Module Data

Hemoglobin or Hematocrit

Hemoglobin or Hematocrit Update

Hemoglobin or Hematocrit Update

Clinical Actions

Intervention Analysis

Intervention Analysis

Intervention Analysis

Intervention Analysis

Intervention Analysis

Intervention Analysis

Intervention Analysis

Clinical Actions

Derived Value Calculator and

Event Review

More

Derived Value Calculator

Event Review

EV1000 Clinical Platform

Choose the EV1000 clinical platform and

the choice of the parameters you want,

how you want to view them—and bring

clarity to every moment.

For Professional Use. CAUTION: Federal (United States) law restricts this device to sale by or on the order

of a physician. See instructions for use for full prescribing information, including indications,

contraindications, warnings, precautions and adverse events.

Edwards, Edwards Lifesciences, the stylized E logo, EV1000, FloTrac, PediaSat, PreSep, TruWave and VolumeView are trademarks of Edwards

Lifesciences Corporation.

© 2011 Edwards Lifesciences Corporation. All rights reserved. AR06594

Recommended