Dual Filtration, High Quality Pressurized Filters · 2017. 3. 24. · Barb Part # BARB1 BARB1 BARB2...

Preview:

Citation preview

  • How does the EasyPro Pressure Filter work?• Thepondfilterisplacedin-linebetweenthepondpumpand

    thewaterfall.• Waterentersthefilteratanangle,creatinga

    vortexinsidetheEasyPropressurefiltertosettleoutthesoliddebris.

    • Waterisforceddownthroughthreelayersofspecialdensityfoampads.Becausethewaterispressurizedthefoamcanfillwithmanymorebeneficialbacteriawithoutbecomingblocked.Itisthislargernumberofbacteriatakingpollutantsoutofthewaterthatmakepressurefilterssoeffective.

    • Thewaterthenpassesthroughtheplasticbiomediawheremorebeneficialbacteriacleansthepollutants.

    • TheUVlightisthenusedonthepassingwatertokillfreefloatingalgaecellswhichcausegreenwater.

    • Asthefoamlayersinthepressurefiltercollectsolids,thecleaningindicatoronthelidwillriseup.Thissignalsthatthefoamlayersneedcleaning.

    Thesefilterstakeindirtywaterfromthepumpandreturnsparklingclearwatertoyourpond,minusthesolidsandgreenalgae.TheEasyPropressurefilterisidealforpondkeeperswhowantsimplicity,clearwaterandanattractive,hiddenfiltersystem.

    ECF10 • ECF10U • ECF25 • ECF25U • ECF40 • ECF40U

    Dual Filtration, High Quality

    Pressurized FiltersInstructions for Operation • Safety • Warranty

    1

  • Pressure Filter InstallationPlease read all instructions carefully and keep for future referenceSafety and Electrical Connections• Always disconnect the electrical supply before starting to handle, maintain, repair or install

    any pond equipment.• Thisproductisnotsubmersibleanditmustbesitedwhereitcannotfallintothewaterorbecome

    waterlogged.However,thedesignisweatherresistant,andEasyProfilterscansafelybeinstalledoutdoors.

    • DirectexposuretoUltra-Violetlightcandamageeyesandskin.Donotattempttoviewthelampwhenlit,exceptbrieflythroughtheviewingwindow.

    • ConnectthisproductonlytoareceptacleprotectedbyaGroundFaultCircuitInterrupter.(GFCI)• Protectfromthefrost.Ifthepondisnotgoingtorunallwinter,drainthefilterandremovefromthe

    groundandstoreinawarmdryplace.• Allelectricalworkmustbeperformedbyaqualifiedtechnician.AlwaysfollowtheNationalElectrical

    Code(NEC)ortheCanadianElectricalCodeaswellasalllocal,stateandprovincialcodes.Codequestionsshouldbedirectedtoyourlocalelectricalinspector.FailuretofollowelectricalcodesandOSHAsafetystandardsmayresultinpersonalinjuryorequipmentdamage.Failuretofollowmanu-facturer’sinstallationinstructionsmayresultinelectricalshock,firehazard,personalinjuryordeath,damagedequipment,provideunsatisfactoryperformanceandmayvoidmanufacturer’swarranty.

    Installation of the Pressure Filter1. TheECF10U,ECF25UandtheECF40UcomewiththeUVlightalreadyinstalled.2. Positionpumpatthefurthestpointfromthewaterfall.Runthetubingoutofthepondandburyor

    concealthetubing.3. ItisrecommendedthatthepumpbehousedinanEasyProskimmerorinanEasyProsubmersible

    pumpprotector.4. Positionthepressurefilteranywherearoundthepond.Sincethedischargeisunderpressure,the

    filtercanbelocateddownhillfromthewaterfall.5. Digaholebigenoughforthefiltertositin.Digtheholedeepenoughsotheretainingringisleft

    exposedoutoftheground.6. Ifinstallingaunitwithclips,makesuretheclipsareleftexposedoutoftheground.7. Recessthefilterintothepreviouslydughole.8. Connectthetubingfromthepumptotheblackbarbedfitting,whichattachestotheintake,whichis

    markedwithanarrowpointingin.9. Connectthetubingfromthewaterfalltotheclearbarbedfittingthatisthenattachedtothedis-

    charge,whichismarkedwithanarrowpointingout.10.Runthetubingtothewaterfallandburythetubingforthebestlook.11.IfthepressurefilterunitisequippedwithaUVlightmakesureitisproperlypluggedintoaGFCI

    protectedoutlet.12.Backfillaroundthepressurefilter.Concealyourpressurefilterandtubingwithyourchoiceofland-

    scaping.

    2

  • Figure5

    Figure4

    Figure3

    Figure2

    Lamp Replacement1. Makesuretheunitis

    disconnectedfromthepowersource.

    2. FortheECF10(U)proceedtostepthree,thenproceedtostepfiveandcontinue.FortheECF25(U)andECF40(U)proceedtostepfour,thenpro-ceed.

    3. Loosenthescrewsonthetopretainingring.Do not remove the screws - do not remove the retaining ring.TwisttheUVhousingandmatchthearrowontheUVcoverwiththearrowontheretainingring.GentlypulluponthecordandcoverinthebacktoloosentheUVcover.(seefigure1and9)

    4. LoosenandremovethethreescrewsontopoftheUVcover.(seefigure2)

    5. RemovetheUVcoverandsetaside.(seefigures3&4)

    6. Removethetwoscrewsandtheplasticretainerclipthatholdthecordinplaceandsetaside.(seefigure5)

    7. UnscrewtheUVlightandcarefullyremovefromthehousing.(seefigure6)

    Figure63

    Figure1

  • 8. UseacleanclothtoremovetheUVlightbygentlypullingupontheUVbulb.(seefigure7)

    9. Do not touch the bulb with your fingers.

    10.Carefullyremovetheblackprotectorontheendofthebulb.InstalltheblackprotectorontheendofthenewUVlightbulb.(seefigure8)

    11.CarefullyinstallthenewUVbulbinthebase,besuretouseacleanclothtoinstallthenewbulb.Pressthebulbfirmlyintothebaseuntilyouhereaclick.(seefigure7)

    12.Carefullyslidethenewbulbintothesleeveandscrewthecapintoplace.

    13.Reattachthecordretainerclipwiththetwoscrews.14.If you have an ECF25U or an ECF40UsettheUVcover

    backontopofthepressurefilterandtightenthethreescrews.

    15.If you have an ECF10UmakesuretolineupthepowercordinthebackwiththeslotintheUVcover.BesuretolineupthetwoslotsinthefrontoftheUVcoverwiththetwoprongsbehindthedischargeconnection.PushdownontheUVcoverandlineupthearrowontheUVcoverwiththearrowontheretainingring.(seefigure9)

    16.TwisttheUVhousingbacktodesiredpositionandtightenthescrewsdownontheretainingring.

    UV Sleeve Replacement and Cleaning1. Makesuretheunitisdisconnectedfromthepowersource.2. Unscrewthebarbedfittingsfromtheinletandoutletonthe

    filter.3. Loosenthescrewsonthetopretainingring.Removethe

    screws.Theretainingringshouldnowbeloose.(seefigure1)

    4. RemovetheUVcoverandsetaside.(seefigure3)5. Removethetwoscrewsandtheplasticretainerclipthat

    holdthecordinplaceandsetaside.(seefigure5)6. UnscrewtheUVlightandcarefullyremovefromthehous-

    ing.(seefigure10)7. CarefullysettheUVbulbaside,beingcarefulnottotouch

    theUVbulb.

    Figure9

    Figure10

    Figure114

    Figure7

    Figure8

  • Figure16

    Figure15

    Figure14

    Figure13

    8. GentlypullstraightuponthethreadedconnectioninthemiddleandremovetheUVhousing.(seefigure11)

    9. Besuretopullstraightup.DonotbendsidewaysastheUVsleeveisglassandcanbreak.

    10.Carefullyremovetheglasssleevebypullingstraightdown.Glassisveryfragile,usecautionwhenremovingandhan-dlingbrokenglass.Cleantheglasssleevewithacleandampcloth.(seefigure12)

    11. ReinstalltheblackendpieceontheendofthesleeveandcarefullyslidetheUVcoverbackintoplace.

    12. TheUVsleevewillslidearoundablackringandwillonlygoinabout1/2".

    13.CarefullyplacetheUVhousingandbulbbackintothefilter.(seefigures11&10)

    14.Reattachthecordretainerclipwiththetwoscrews.(seefigure5)

    15.MakesuretolineupthepowercordinthebackwiththeslotintheUVcover.(seefigures3&9)

    16.InstalltheUVlightcoverandscrewdowntheretainingring.(seefigure1)

    17.Reattachthebarbedfittingstothepressurefilter.

    Pressure Filter Cleaning1. Thereisacleaningindicatoron

    thetopofthefilter.Itwillbegreeninnormaloperation.Whenthefil-terneedstobecleanedtheindi-catorwillturntored.(seefigures14&15)

    2. Whenthisoccurs,ifthepressurefilterisequippedwithUV,disconnectthepumpfromthepowersource.

    3. Ifthefilterisapressurizedunit,thepressuremustbere-leasedbeforeremovingthelid.Thiscanbedonebydisconnectingtheinletandoutlethoses.

    4. IfyourunitisanECF10orECF10U,youwillneedtoundothefourretain-ingclips.IfyourfilterisanECF25(U)orECF40(U),youwillneedtoreleasethetensionring.(seefigures16,17&18)

    5

    Figure12

  • Figure21

    Figure22

    Figure19

    Figure20

    Figure17

    Figure18

    6

    5. Pulluponlidassemblyandsetaside.(seefigure19)6. Removethefilterpadsandrinseoutwithcleanwater.7. Ifthefilterpadsaredeteriorated,discardandreplace

    withnewpads.8. Seereplacementpartschartforthecorrectsizeand

    partnumberforyourpressurefilter.9. Ifthereisexcessbuildupinthebottomofthepres-

    surefilter,youcanrinseitoutbutdonotclean100%.Thisiswherethebeneficialbacteriagrow.(seefigure21)

    10.Replacethefilterpadsandinstallthelidassemblyandclampdownwithretainingclipsortensionring.(seefigures16&18)

    11.Ifforsomereasonthelargeo-ringcomesoff,itisbesttoputitbackonthelidassemblyinsteadofthefilterbucket.(seefigure22)

    12.Hookhosesbackup,plugintheUVlampandturnthepumpbackon.

  • Part # ECF10 ECF10U ECF25 ECF25U ECF40 ECF40UMaximumPondSize(gallons)* 1000 1000 2500 2500 4000 4000UV/Watts None Yes/7 None Yes/9 None Yes/13Inlet/Outlet 1/2", 1/2", 3/4",1" 3/4",1" 3/4",1" 3/4",1"Sizes 3/4",1" 3/4",1" 11/4",11/2" 11/4",11/2" 11/4",11/2" 11/4",11/2"RecommendedmaximumGPH 600 600 1350 1350 2000 2000ReplacementFilterPart# ECF10F ECF10F ECF25F ECF25F ECF25F ECF25FUVBulbPart# None 10UB None 25UB None 40UBUVSleevePart# None 10US None 25US None 40USInlet/OutletHoseBarbPart# BARB1 BARB1 BARB2 BARB2 BARB2 BARB2

    *Fish load, amount of sunlight, etc. all affect actual maximum gallons filtered.

    7

  • Warranty:Thisproductiswarrantiedagainstanymechanicalormaterialdefectsforaperiodofoneyearfromthedateofpurchase.Warrantyonlycoversproperlyinstalledandmaintainedunits.Thewarrantydoesnotcovernormalwearandtear,noranydeteriorationsufferedthroughoverloading,improperuse,negligenceoraccident.Similarly,anymodificationmadebythepurchasertotheprod-uctwillcausethewarrantytobenullandvoid.Allreturneditemswillbeinspectedtodeterminecauseoffailurebeforewarrantyisapproved.Warrantydoesnotcoveranycostassociatedwiththeinstallationorremovaloftheproductsubjecttowarrantyclaim.AnRAnumbermustbeobtainedbycallingEasyProPondProductsat800-448-3873.Itisyourre-sponsibilitytopaythereturnshippingcharges.BesuretoincludetheRAnumber,originalreceipt(intheformofaninvoiceorsalesreceipt),name,returnaddressandphonenumberinsideofthepack-age.Nowarrantyclaimswillbehonoredwithouttheoriginalreceipt.Ensuretheproductisproperlypackagedandinsuredforthereplacementvalue.Damageduetoim-properpackagingistheresponsibilityofthesender.Themanufacturerorsuppliershallnotbeheldliableforanydamagescausedbydefectivecompo-nentsormaterialsofthisproduct;orforlossincurredbecauseoftheinterruptionofservice;oranyconsequential/incidentaldamagesandexpensesarisingfromtheproduction,sale,useormisuseofthisproduct.Themanufacturerorsuppliershallnotbeheldliableforanylossoffish,plantsoranyotherlivestockasaresultofanyfailureordefectofthisproduct.

    800-448-3873•Grant,Michiganwww.easypropondproducts.com•info@easypropondproducts.com 1-14