View
317
Download
1
Category
Preview:
Citation preview
Draeger Controllers
REGARD 3920 REGARD
DRAEGERGARD 8/16 DRAEGERGARD PLUS
DRÄGER SAFETY INC• SYSTEM CENTER, HOUSTON
JAN, 2013• 4 /73
PLC CONTROL SYSTEM
DRÄGER SAFETY INC• SYSTEM CENTER, HOUSTON
JAN, 2013• 5 /73
UPGRADING EXSISTING CO DETECTION SYSTEM IN
STEEL PLANT
EXISTING DETECTORS
+ NEW DETECTORS
HARD-WIRING
+WIRELESS
ETHERNET/IP
AB PLC+WIRELESS
+ TOUCH PANEL
42” TV MONITOR
DRÄGER SAFETY INC• SYSTEM CENTER, HOUSTON
JAN, 2013• 6 /73
SEQUENTIAL SAMPLING SYSTEM
DRÄGER SAFETY INC• SYSTEM CENTER, HOUSTON
JAN, 2013• 7 /73
WIRELESS APPLICATIONS
Point to Multi-Point
RS485(Modbus RTU)
Node 1
Node 2
Node 47
Node 46
Gateway
DRÄGER SAFETY INC• SYSTEM CENTER, HOUSTON
JAN, 2013• 8 /73
APPLICATIONS
Wireless Transmitters Powered By Solar System
DRÄGER SAFETY INC• SYSTEM CENTER, HOUSTON
JAN, 2013• 9 /73
APPLICATIONS
Wireless Transmitters
REGARD 3900 | Gavin Peacock | 22.01.2010 11 | 18
LCD
Display
System
Status
LEDs
Operation
Buttons
Channel
Status
LEDs
IP65
Enclosure
Allen bolt
REGARD 3920
PRODUCT OVERVIEW
REGARD 3900 | Gavin Peacock | 22.01.2010 12 | 18
• Options for Inputs & Outputs
• 1 input board + 2 relay boards (max)
• 2 input boards + 2 relay boards
• 3 input boards + 1 relay board
• 4 input boards & no relay boards
• In addition to the above
• 2 repeat output boards
There can never be more than 4 Input and Relay boards installed
REGARD 3920
PRODUCT OVERVIEW
Regard 3920
Regard 3920
Control System
Regard
• Central control system
• Multiple input and output options
• 99 Input channels per system
• Simple I/O distribution
• PC and pushbutton configuration
• Flexible
• The Master Card communicates over the internal
BUS with the Channel Card (Slaves) and controls
the Channel Cards in the System.
• The 3 relays on the master card can be cofigured
as either master alarms or voting alarms wrt all
the other cards in the system.
• Input for remote reset.
• Additional Master cards (extra Master) provide
extra relay configurations.
• A 4-digit Display shows the functions when the
pushbuttons are used to configure Gasname,
device and Measuring range of all Channel Cards,
confirmation and configuration.
• 6 Led´s for Status display (Alarm,
troubleshooting....)
• Master control of slave card readings and settings.
• Master acknlowledgement of system status.
• ATEX Certificate !!
• The 4..20mA Channel Card is for all 4..20mA
Transmitters (P3000, P7000, PIR7000...).
• 3 Alarm relays A1,A2, A3/Fault.
• Input for remote reset.
• A 4-digit Display shows the gas concentration and
functions when the pushbuttons are used to
configure Gasname, device and Measuring range
of all Channel Cards, confirmation and
configuration.
• 6 Led´s for Status display (Alarm,
Troubleshooting....)
• Analogue Output 4-20mA and 0-20mA.
• ATEX Certificate !!
• 8-Way Channel Card
• All 2-/3-wire 4..20mA associated transmitters.
• 3 Alarm relays A1,A2, A3/Fault common for all 8 channels.
• Input for remote reset.
• Display Card and 8-channel module utilising RS485 (max 1000m).
• A multi digit display for the Gas readings of Transmitters. Functions
available on the frontplate for setting display of Gas name, Measuring range
and for Configuration.
• 6 Led´s for Status display (Alarm, Troubleshooting....)
• The 4..20mA Module is Standard rack mounting. The module can be field
mounted.
• ATEX Certificate !
• The Relay Display Card can control 16 Relay modules maximum (256
Relays).
• Relay-Display Card and the Relay modules communicate over RS-485.
• 1 Fault relay and input for remote reset.
• Relay-Display card and Relay module utilising RS485 (max 1000m).
• The multi digit display shows the status of all the relays.
• Functions available on the frontplate for setting alarm types and
configuration.
• Led´s for Status display (Alarm, Troubleshooting.......)
• The Relay module contains 16 Relays, configured for Single, Group or
Voting alarm outputs A1, A2, A3 / Fault configuration.
• The Relay display card is Standard rack mounting. The module can be field
mounted.
• Master-Card
required!
• ATEX Certificate !
• Modbus-gateway for connection in the frame system
for Draeger Visualisation-Software „Vision32“.
• To show Gas concentrations and the Status of alarms
and Faults.
• Additional information of warnings and criticcal card
faults.
• Comes with RS232, 422 and 485 Gateway.
• A 4-digit Display for Configuration and Test.
• Pushbuttons on the front panel for configuration.
• Master-Card Required!
• The Optical Card is for operation with the optical
Transmitters: Polytron IR and Pulsar.
• 4 Alarm relays A1,A2, A3/Fault, „Beam-Block
Warning“
and 1 Transistor-output for „Beam-Block“.
• Input for remote reset.
• A 4-digit Display shows the gas concentration and
functions when the pushbuttons are used to configure
Gasname, device and Measuring range of all
Channel Cards, confirmation and configuration.
• 6 Led´s for Status display (Alarm,
Troubleshooting....)
• Analogue output 4-20mA und 0-20mA.
• ATEX Certificate !!
Regard
DRÄGER SAFETY INC• SYSTEM CENTER, HOUSTON
JAN, 2013• 35 /73
DRAEGERGARD 8/16
COMPACT 16-CHANNEL CONTROLLERS
DRAEGERGARD
UP TO 16 TRANSMITTERS
REGARD 3920
4~20mA INPUT RELAY OUTPUT
DRÄGER SAFETY INC• SYSTEM CENTER, HOUSTON
JAN, 2013• 36 /73
With Touch Screen Panel
DraegerGard 8/16
DraegerGard 8/16
DraegerGard 8/16
DraegerGard 8/16
DraegerGard 8/16
DraegerGard 8/16
DraegerGard 8/16
NEMA 7 ENCLOSURE
DraegerGard 8/16
DraegerGard 8/16
Agenda
Draeger Controllers
1. OVERVIEW
2. REGARD 3920
3. REGARD
4. DRAEGERGARD 8/16
5. DRAEGERGARD PLUS
DRÄGER SAFETY INC• SYSTEM CENTER, HOUSTON
JAN, 2013• 51 /73
DraegerGard Plus
DRÄGER SAFETY INC• SYSTEM CENTER, HOUSTON
JAN, 2013• 52 /73
Compact NEMA 4X
Fiberglass
Wall Mount
NEMA 4X Fiberglass
Wall Mount
NEMA 7
Aluminum Wall
Mount
½ inch and Full Length
19 inch
Rack/Panel Mount
DRÄGER SAFETY INC• SYSTEM CENTER, HOUSTON
JAN, 2013• 53 /73
MENU SCREEN
MAIN DATA SCREEN
BAR GRAPH SCREEN
TREND SCREEN
COMBINATION SCREEN
ZONE SCREEN
DRÄGER SAFETY INC• SYSTEM CENTER, HOUSTON
JAN, 2013• 54 /73
Channel configurations include 16, 32, 48 and 64 (shown) active channels
Indicates alarm status by cell color
Flashing color becomes steady after acknowledge
Displays measurement name, bar graph, engineering units and scaled value
View all active channels on the same screen
DRÄGER SAFETY INC• SYSTEM CENTER, HOUSTON
JAN, 2013• 55 /73
View 16 channels at a time
Displays channel number, bar graph, alarm levels, current reading and engineering
units
Changes in bar graph colors indicate alarm status
DRÄGER SAFETY INC• SYSTEM CENTER, HOUSTON
JAN, 2013• 56 /73
View one channel’s 24 hour trend
Top color bar changes with alarm level
Top data fields include current reading, min - max - average readings over the 24 hours, range, channel
number,
measurement name and Engineering Units
DRÄGER SAFETY INC• SYSTEM CENTER, HOUSTON
JAN, 2013• 57 /73
Upload/download system configuration via SD card
Logged data saves to SD Card
Holds over one year of data at logging rate of every one minute with 2 GB SD Card
16, 32, 48, 64 ChannelGraphic Display & Alarm Controller
SD Card
C h 0 7
P C T L E L
Me a s u r e me n t N a me
5 0Mi n : 0 A v g : 3 2Ma x : 9 5
Z e r o : 0 S p a n : 10 02 7 2 4 2 1 18 15 12 9 6 3 m10 0
8 0
6 0
4 0
2 0
0
Standard
Relay 1
Standard
Relay 2
Standard
Relay 3
Fault
Relay
Horn
Relay
!* DO NOT REMOVE
WHEN LED IS ON
Alarm
Reset
Next Edit
Menu
72-1020
Serial No.
2 4 0 0 C o u n t s
DRÄGER SAFETY INC• SYSTEM CENTER, HOUSTON
JAN, 2013• 58 /73
Ethernet web server allows backup and restore of
system configuration
Web page interface allows remote configuration
View real-time data
DraegerGard Plus
Agenda
Draeger Controllers
1. OVERVIEW
2. REGARD 3920
3. REGARD
4. DRAEGERGARD 8/16
5. DRAEGERGARD PLUS
6. VISION 7000
DRÄGER SAFETY INC• SYSTEM CENTER, HOUSTON
JAN, 2013• 61 /73
VISION 7000
DRÄGER SAFETY INC• SYSTEM CENTER, HOUSTON
JAN, 2013• 62 /73
VISION 7000
DRÄGER SAFETY INC• SYSTEM CENTER, HOUSTON
JAN, 2013• 63 /73
GAS CONCENTRATION
LAYOUT
BAR GRAGH
REAL TIME TRENDING
DATA LOGGING
HISTORICAL TRENDING
ALARMING
……
VISION 7000
VISION 7000
Recommended