View
218
Download
2
Category
Preview:
Citation preview
SIGMA constantly endeavors to improve products so that information in this catalog is subject to change without notice.
Distributed by
After serving for over 30 years as the feet of global villagers,the former LG Elevators and Escalators of LG Industrial Systems Co.,Ltd.lives on with the birth of Sigma Elevator Company.
On the basis of time-tested and valuable expertise, our everlasting ardor for customer satisfaction under the banner of "New Technology," Perfect Quality," and "Best Services" will be sustained by SIGMA Elevator in the new millenium.
BBirth of " SIGMA Elevator "
We are proud to introduce a new generation of escalators with our SCE series.Sigma Commercial Escalators are well suited for today’s urban structures. New technologicaladvancements have been applied to make the escalators the world-best in design and safety.New technology and aero-dynamic design make Sigma escalators appealing while improvedstrength and safety features offer security to users.Manufactured by the Changwon factory in Korea, Sigma escalators will continue to meetstringent customer requirements with higher goals than expected.With certificates to meet various standards around the world, we offer the best quality andsafety with Sigma escalators.
Overview of the Changwon factory, Korea
Micom ControllerFault Code Display (LED)Traffic Information Display InterfaceDouble Coil BrakeLower Starting Shock (Y-¡ start)Remote Monitoring Interface
W orm HelicalM a chine
High EfficiencyLow NoiseReliable Brake SystemSafety Provisions
CompactVertical worm helical machineCompact designEfficient maintenance
New TechnologyBetter world with Sigma Escalators...
Artistic design, best safety and best ride. N ew concept of engineering resulting safe
and low noise SIGMA Escalator .A different escalator...
Maintenance Ro o mClear area expanded (EN Code applied)
3 | 4SIGMA Escalator
RobustStrength with the comfort andlow noise
Design Artistic design with smoothand natural lines
SafetyElimination of the source ofsafety hazards
Aero-Dynamic Design
Silver(Option)BlackBlue
Clear Green(Option) Bronze(Option)
Aluminium Aluminium(Option) Stainless steel(Option)
Direction indicator Various colors forhandrails
Ebony(Black) ES-01Scarlet ES-10(Option)Sapphire ES-27(Option)Crimson ES-20(Option)Mid Grey ES-12(Option)Emerald ES-29(Option)
Unique SIGMA escalator design and variousdesign options make possible assimilation withbuilding aesthetics.
Simple and yet, modern design of handrail inlet coupled with slim deck line lampraised escalator design to the next level while maintaining safety
Above colors may differ from the actual color due to printing ( Actual colors may differ)
Glass panel
3 Types of Entry Box
Floor
Better design for a better world...
5 | 6SIGMA Escalator
Robust
One-body stepOne-body steps from step die casting machine
Skirt guardTriple reinforced
structure
Demarcation cleatReinforced to prevent breakage
Aluminium moldStrong aluminium mold
Perfection of strength and sturdiness...
From angle truss to high torsion resisting 4 angled pipe truss...
One-body Step escalator die casting machineHardness enhanced to prevent fractures
Existing escalator frame
Existing escalator truss structure
SIGMA Escalator7 | 8SIGMA Escalator
Safety measures surpass EN115 of Europe!User safety comes first in SIGMA escalators
Controller Lifting Device Comb Plate Switch Safety Guard at upper andlower machine rooms
Step Safety Switch Lock/Tag-out Switch Entry Switch Skirt Guard Safety Device Driving Chain Safety Device
Step Roller Safety Device Step Chain Safety Device Emergency Stop Device /Operation Monitoring LED
Expanded Maintenance Area
Gap between step and skirt guardSurpassed EN Code requirements
Entry boxHandrail inlet engineered throughmock emergency tests
HandrailEngineered to prevent fingers gettingcaught between frame and handrail
Safety is the foundation of design...
9|10SIGMA Escalator
Structure and Safety Device
New Generation Escalator
Self-diagnostic functions with remotecommunication
Engineered through field know-how
Advanced safety system with robust design
Emergency Stop Device & OperationMonitoring(LED)In an emergency, stops the escalator immediately if pressed.Operation Monitoring LED
Flickering : requires removal of foreign material and re-start bysite managersOn : requires repair by maintenance personnel
Step Safety SwitchStops escalator if steps areoperating in abnormal manner dueto fractured step
Step Chain Safety DeviceStops escalator if the step chainbreaks or becomes loose.
Skirt Guard Safety DeviceStops escalator if objects are caughtbetween step and skirt
Controller Lifting DeviceFor easy removal of controllerduring maintenance
Driving Chain SafetyDeviceStops escalator if the driving chainbreaks or excessively loosened
Comb Plate Safety SwitchStops escalator if objects are caughtbetween comb plate and step treads.
Entry SwitchStops escalator if hand or object ispulled into the handrail inlet
Step Roller Safety DeviceStops eacalator if steps are operating in abnormalmanner due to reasons such as foreign matters beingcaught between steps.
Non-reversing Safety DeviceStops escalator if its direction of travel is reversed
Additional option safety devices
Overspeed Detector Stops escalator if operating above normal speedAuxiliary BrakeStops escalator if the driving chain breaks or over-speeds
Brake Lining Wear Safety DeviceStops escalator if the lining of main brake is worn abnormally
Handrail Speed Detector Stops escalator if handrail speed is below norm due to handrail breakage or elongations
Handrail Stop Device Stops escalator if handrail breaks or stops
Handrail Static Preventor Prevents static electricity with handrail rollers installed blocking static electricity
HANDRAIL
DECK
GLASS PANEL
DRIVING UNIT
STEP
COMB
CONTROLLER
TRUSS
RAIL
HANDRAIL DRIVING PULLEY
SKIRT GUARD
EMERGENCY STOP DEVICE
FLOOR
HANDRAIL ENTRY BOX
11|12SIGMA Escalator
K
600
FL. FL.
FL.FL.
Layout & Dimensions
Specification
From material to manufacturing engineering, researchworks are unified and focused to enhance our escalatortechnology.
13|14SIGMA Escalator
FINISHED FLOOR
WORKING POINT WORKING POINT
L=L1+A+B+100
MIN.M
H(RI
SE)
JM
IN.K
D
800
J
H(RI
SE)
K
FL.
FL. FL.
L1=(30 =1.732 H,35 =1.428 H)
RAILING
(BY OTHERS)
(BY OTHERS)
EXTERIOR PANEL
W.PPOWER SUPPLY
F
W.P
R1
R2
W2W1
W3
MIN.PIT WIDTH
MIN
.PIT
DEP
TH
FINISHED FLOOR
W
200
G
E
GUARD AT CEILING
MIN
.230
0
C
50
600
AB50
(BY OTHERS)
FINISHED FLOOR(BY OTHERS)
T
Support Loads
Through product development focused on safety and comfort, traveling up ordown in buildings or department stores is safe, quick and convenient.
Angle ofinclination
SCE 30
SCE 35
SCE 30
SCE 35
30
35
30
35
2
2
1.5
1.5
2050~6000
2050~6000
2050~6500
2050~6500
R1(kg)
0.64H + 2500
0.52H + 2800
0.64H + 2100
0.52H + 2600
R2(kg)
0.64H + 1900
0.52H + 2300
0.64H + 1500
0.52H + 2100
R1(kg)
0.80H + 3100
0.67H + 3400
0.76H + 2800
0.67H + 3000
R2(kg)
0.80H + 2500
0.67H + 2800
0.76H + 2400
0.67H + 2300
Type
LoadModelNo.of Flat Step Rise
800 Type 1200 Type
270 50
140
140
320
(Concrete Support Structure)
250250
140140
5050 MIN.300MIN.300
MIN.200MIN.200
140
140
(unit : mm)Frame Support
FINISHED FLOOR(BY OTHERS)
BASE PLATE
BASE PLATE
BASE PLATE
STEEL BAR(BY OTHERS)
SUPPORT PLATE(BY OTHERS)
BASE PLATE
SUPPORT PLATE(BY OTHERS)
STEEL BAR(BY OTHERS)
FINISHED FLOOR(BY OTHERS)
FINISHED FLOOR(BY OTHERS)
RIB(BY OTHERS)RIB(BY OTHERS)
FINISHED FLOOR(BY OTHERS)
320
140
140
27050
(Steel Beam Support Structure)
LOWER END UPPER END
LOWER END UPPER END
When H is above 6,000mm, consult Sigma for further details.When L is over 16,000mm, an intermediate support is required.For no intermediate support and when L is over 16,000mm,
consult Sigma for further detailsGiven dimensions may change without advance notice
ModelType
Dimension
2050 ~ 6500
2050 ~ 6000
2050 ~ 6000
2050 ~ 6000
800 1200
2215 2215
2915 2415
2290 2290
2990 2490
1945
2145
2020
2220
1665
1865
1740
1940
1395
1595
1470
1670
730
730
730
730
30
30
35
35
950
950
950
950
1020
1020
1020
1020
1100
1100
1100
1100
2300
2300
2000
2000
1.5
2
1.5
2
Rise(H)No.ofFlatStep
SCE30
SCE30
SCE35
SCE35
unit : mmDimensionsA
B C D E
E: Incase of EN115 compliance, E is 800mm
F G J K M
ModelType
Dimension
2050 ~ 6000
Rise(H)
SCE30 & SCE 35
Step Width W W1 W2 W3
800
604
1200
1004
800
609
1200
1009
800
820
1200
1220
800
1150
1200
1550
800
1250
1200
1650
Standard SpecificationsPart Material
Balustrade
Floor
Step
Handrail
Handrail Frame
Deck Cover
Panel
Comb
Comb Plate
Floor
Cleats and Riser
Demarcation Line
Note) For other optional specifications, please contact Sigma Elevator Company
Composite rubber
Aluminum
Stainless Steel with Hairline finish
Tempered glass
Aluminum
Aluminum
Aluminum
Aluminum with gray color paint
Yellow Synthetic resin on three sides
800Type
800mm
604mm
4500 Passengers/hour
1200Type
1200mm
1004mm
9000 Passengers/hour
30m/min
30 / 35
AC 60/50 Hz, 380~440V
Three Phase Induction Motor
Reversible System
Construction
Type
Nominal Width
Tread Width
Capacity
Speed
Angle of Inclination
Power Source
Driving Motor
Operation System
Standard
EN 115
Motor TypeModel 5.5kW 7.5kW 9.5kW
SCE30
SCE35
SCE30
SCE35
800
1200
800
1200
800
1200
800
1200
Lead-in Wires( ) 3.5
MCCB CAPACITY OF BUILDING(A)
5.5
30
5.5
4020400V
Power Source 400V
Power Source
5.8m
4.5m
5.8m
4.5m
4.5m
3.4m
4.5m
3.4m
6.5m
6.5m
6.0m
6.0m
6.0m
4.8m
6.0m
4.9m
6.0m
6.0m
15|16SIGMA Escalator
All dimensions are minimum(unit : mm)Dimensions of < > is in case of transferring escalatorwithout BalustradeFor detailed information, please consult Sigma
Well holes on the center line of escalator (carrying force min.6,500kg)
Well holes on the center line of escalator (carrying force min.5,500kg)
Side Entrance Floor / Ceiling Entrance
Well Hole Entrance Dimensions
1950
3000
<23
00>
4800<4600> 1950
No.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
Works by Others
Cutting and patching of any holes needed to install the escalator
Providing bases and supports for installation
Providing clear access to well ways.
Providing a pit and moisture proofing at the lower end of escalator
(If there are rooms occupied below this level, the pit must be of fire-resistant construction)
Finishing the floor and ceiling around the escalator after installation
Installation of safety railings around the escalator
Installation of exterior truss panels or other external decoration
Installation of delta guard at all intersections either between escalators
or between escalator and ceiling
Installation of barriers and safety railings in the space between paired escalators
Finishing ceilig edges, etc., around escalator wells
Installation of safety net in the ceiling space between paired escalators, if required
Providing clear access for equipment and all necessary building renovation work for existing
buildings where escalators are to be installed
Providing proper finish works around escalators for existing building installations
Proper safety protection, within 500mm from the handrail out side and 2,100mm from flooring,
against any columns or open ceilings, etc.
Any connection works for interfaces with building s fire emergency protocols
No.
16
17
18
19
20
21
22
Works by Others
Installation of power line wiring to the upper escalator machine room
Installation of maintenance line wiring to upper escalator machine room
Installation of earth(ground) lines to upper escalator machine room
Installation of power supply and switches for escalator lighting
Installation of building equipment such as sprinkler system, public address systems and signs
Installation of power supply and switches for escalator lighting in lower ends
Installation of 4 non-Voltage lines (2 upper, 2 lower) for fire shutters
Building Construction
Electrical Wiring
Recommended