View
217
Download
0
Category
Preview:
Citation preview
w w w . e m p i r e z o n e h e a t . c o m
• MatchlessPushbuttonPiezoignition
• NoelectricityneededforWallThermostatoperation
• Totalcomfortforafractionofthecostofelectricheat
• Optionalautomaticbloweravailable
• Cost-efficientinstallation–nochimneyisneeded
• Heatswithoutelectricity
• Includesstandardventkitthroughoutsidewall
D I R E C T- V E N TWALL F U R N AC E S
S U R R O U N D Y O U R S E L F W I T H C O M F O R T
When you need to heat a single room or an entire home, Empire has Direct Vent Furnaces to suit your needs.
Empire Direct-Vent Wall Furnaces are specifically designed for areas where flues or chimneys are not available or cannot be used. Empire Direct-Vent heaters have removable front panels for easy cleaning and servicing.
With a Direct-Vent system, there is a positive difference in fuel economy because outside air is used to support combustion. The air on the inside is warmed as it recirculates around a sealed chamber. This warm air heats the room cleanly and efficiently.
DV S e r i e s D i r e c t - V e n t W a l l F u r n a c e s
THE EMPIREDIRECT-VENT ADVANTAGE
FOR SMALLER ROOMS
PRODUCTS OF COMBUSTION
PRODUCTS OF COMBUSTION
AIR FORCOMBUSTION
Empi re ’ s D i rec t -Vent wa l l fu r naces are idea l where ex i s t ing f lues o r ch imneys cannot be used . Jus t one ho le th rough an outs ide wa l l i s a l l you need . I f you must vent , you w i l l rece i ve max imum fue l economy f rom Di rec t -Vent heater s .
Cleanandcost-efficientcomfortmaketheDV–210andDV–215theperfectheaterstowarmyoursmallerrooms.Theslim,compactdesignallowstheheatertotuckoutofthewayonanoutsidewall.Quietburners,a“matchless”piezoignition,andallthesafetyfeaturesyouexpectfromEmpireComfortSystemscomestandard.
Optionalautomaticblowers installeasily formoreevenheatdistribution. Our reliable millivolt wall thermostat needsno electricity, so you stay warm even when electric powergoesout.
Idealforbedroomsorstudies,wallfurnacesaddcomfortandbeautytoanydecor.
DV-210 (10,000 Btu)
DV-215 (15,000 Btu)
DV-210Typical DV-210 Installation
2 EmpireHeat ing Systems • www.empirezoneheat .com
DV S e r i e s D i r e c t - V e n t W a l l F u r n a c e s
FOR LARGER ROOMSHeatlargerareaswithEmpire’sDV–25andDV–35Direct-Ventwall furnaces.Deliveringroom-fillingwarmth,each furnace isstylishlycraftedandfitsagainstanoutsidewall.
Apushofthebuttonignitesthepilotwitha“matchless”piezosystem.Addanoptional internalblower forevengreateraircirculation.
DV-25 (25,000 Btu)
DV-35 (35,000 Btu)
Typical DV-35 InstallationDV-35
Empire’ssecrettoquieteroperationisouruniquelydesignedburner.Asgasenterstheburnerport,itisignitedimmediately,whicheliminatesdelayedignitionnoiseandgivesyouquieteroperation.
Clean,smartengineeringontheinsidecallsforclean,smartlooksontheoutside.ThesimpleDirect-Ventcapontheexteriorofyourhomeprojectsonly5inches.And,withtheoptionalvinylsidingkit,installationonvirtuallyanytypeofhomeispossible.
The Empire FINISHING TOUCH
SafetyisengineeredintoeveryEmpireDirect-VentFurnace.Eachunitcontainsanautomaticshut-offvalveshouldthepilotlightbecomeextinguished.And,Empire’squalitycontrolproceduresensurethateveryheater isatopperformerbefore itgoesintoyourhome.
Empire leads the field in style and durability.We use a state-of-the-art powdercoatingthatproducesastrongfinishthatresistsscratchingandchipping.
Safety Is EVERYTHING at Empire
The optional wall thermostat (included), requiring no electricity, provides reliable round-the-clock comfort.
www.empirezoneheat .com • EmpireHeat ing Systems 3
Model DV-210-SG DV-215-SG DV-25-SG DV-35-SG
Color:CabinetandFrontPanel Beige Beige Beige Beige
BtuInput 10,000 15,000 25,000 35,000
Overall Dimensions
Width 161/4” 201/4” 37” 37”
Depth 93/8” 93/8” 111/2” 111/2”
Height 213/8” 247/8” 273/4” 273/4”
ShippingWeight,lb.(OneCarton) 42 60 98 101
Temperature Control
OptionalMillivoltWallThermostat(Included) Yes Yes Yes Yes
Accessories (State on Order)
WirelessRemoteWallThermostat TRW TRW TRW TRW
BlowerKit DVB-1 DVB-1 DRB-1 DRB-1
Output,Cu.Ft./Min. 60 60 75 75
VinylSidingKit VSK-1 VSK-1 VSK-2 VSK-2
VinylSidingVentKit DV-822 DV-822 DV-822 DV-822
VentTubeExtensionKit(Fitswallfrom13”to19”) * * * *
Minimum Clearances to Combustibles from:
Top 12” 12” 48” 48”
EachSide 1” 1” 6” 8”
BottomofUnittoFloorCovering 0” 0” 4” 4”
Gas Inlet
TypeofGas(StateonOrder) NaturalorLP NaturalorLP NaturalorLP NaturalorLP
IronPipeSize(N.P.T.) 1/2” 1/2” 1/2” 1/2”
WalltoValveInlet 63/16” 63/16” 4” 4”
RightSidetoValveInlet 67/8” 67/8” N/A N/A
CenterofVenttoValveInlet N/A N/A Left1711/16” Left1711/16”
ValveInlettoFloorCovering 211/16” 211/16” N/A N/A
Venting
WallDepthMinimum 41/2” 41/2” 41/2” 41/2”
WallDepthMaximum 13” 13” 13” 13”
VentOpeninginWall 61/2”Dia. 61/2”Dia. 61/2”Dia. 61/2”Dia.
CenterofVenttoNearestOutsideCornerofBuildingorObstruction 16” 16” 24” 24”
CenterofVentfromanyOpeningthroughwhichFlueGasesCouldEnteraBuilding 6” 9” 9” 9”
BottomofVentaboveGrade 12” 12” 12” 12”
EdgeofVenttoNearestProjectingSurface 6” 6” 6” 6”
VentProjectionfromOutsideWall 4” 4” 5” 5”
CenterofFluetoFloorCovering 157/8” 193/8” 193/4” 193/4”
Safety Control
PilotandMainBurnersincludeAutomaticShut-off.
Warranty
CombustionChambercarriesa10-yearwarranty.Allotherpartscarrya1-yearlimitedwarranty.
*VentTubeExtensionKitAvailable.PleaseContactEmpirePartsDepartment.Thisappliancemaybeinstalledinanaftermarketpermanentlylocated,manufactured(mobile)home,wherenotprohibitedbystateorlocalcodes.
Due to high temperatures, the appliance should be located out of traffic and away from furniture and draperies.
Children and adults should be alerted to the hazard of high surface temperature and should be kept away to avoid burns or clothing ignition.
Installation and repair should be done by a qualified service person.
This series is design certified in accordance with American National Standards Institute Z21.86 and the National Standard of Canada
CSA 2.32 by the CSA Standards and the Canadian Gas Association as a Gravity Direct Vent Wall Furnace.
The installation must conform to local codes. In the absence of local codes, the installation must conform with American National Standard (National Fuel Gas Code) known as NFPA 54 and ANSI Z223.1 (latest edition) available from the American National Standards Institute, Inc., 11 West 42nd St., New York, N.Y. 10036, or from the National Fire Protection Association, Batterymarch Park, Quincy, Massachusetts 02269.
FOR YOUR SAFETYRead your Owner’s Manual for complete installation and safety information
w w w . e m p i r e z o n e h e a t . c o m
©EmpireComfortSystems,Inc.EHS-00048062413
EmpireComfortSystems918FreeburgAve.Belleville,IL62220-2623E-mail:info@empirecomfort.com
CERTIFIED
Standard vent cap mounted on outside wall
Vent cap with optional DV-822 Vinyl Siding Vent Kit accessory
VSK-1 & standard cap mounted on vinyl siding
Recommended