View
93
Download
3
Category
Preview:
Citation preview
Mechron Power Systems2437 Kaladar AvenueOttawa, OntarioCanada K1V 8B9
Tel: (613) 733-3855Fax: (613) 733-8197
www.mechron.com
A Division ofToromont Industries Ltd.
Product Sheet
DCG Series DC Generator Sets Mechron’s DCG line of generator
sets is designed for use in DC
prime, standby and hybrid-
renewable applications. DCG
generators ensure continuous
operation of your equipment,
providing automatic start to
charge station batteries in the
event of utility or rectifier failure
or low station batteries. DCG
generators feature advanced
microprocessor controls and
available remote monitoring and control capability. DCG Series
Generator Sets are available with weather-resistant enclosures for
outdoor installation.
Benefits:
• Simple, redundant battery backup designed for ease of installation
and maintenance
• DC output reduces costs and space requirements and increases
efficiency and reliability over AC solutions. The DC output
connects directly to the station battery, bypassing rectifiers; no
transfer switch is required
• Seamless integration with hybrid-renewable systems, including
solar, wind and Mechron’s Cycle Charge™ system
• Automatic operation based on defined conditions including loss of
AC utility power and low station battery voltage ensures
uninterrupted DC power availability
• Available in 4.5 or 7 kW, 24 or 48 VDC, positive or negative ground
• Available in diesel, natural gas and liquid propane gas versions
• Allows for smaller capacity station battery
• Configurable shutdowns and alarms via PC interface
• Remote monitoring, control and configuration via GC View software
or GC WebView web browser interface
Mechron Power Systems2437 Kaladar AvenueOttawa, OntarioCanada K1V 8B9
Tel: (613) 733-3855Fax: (613) 733-8197
www.mechron.com
A Division ofToromont Industries Ltd.
Product Sheet
Features: • Automatic start on loss of AC utility power or low station battery
voltage
• Engine run hourmeter
• Discrete Outputs: Common Alarm, AC Available, Engine Running
• Shutdowns (with indication)
• Low Oil Pressure
• High Engine Temperature
• Overspeed
• Underspeed
• Overvoltage
• No speed signal
• Local Run / Off / Auto settings
• Discrete input for remote Start / Stop / Reset
• RS232 and Ethernet communications ports for remote monitoring
and control and diagnostic interface
• GC View Software: Allows complete remote monitoring, control and configuration of alarms, shutdowns and settings
• GC WebView: Built-in web server for HTTP web-based monitoring
Options: • Outdoor enclosure
• Wind, snow, ice and rain resistant
• Forklift pockets
• Lockable, with tamper resistant hardware
• Available height extension legs up to 1m (39”)
• Available sound-attenuation – 67 dBA @ 25 feet (7.6m)
• Cold weather package
• Extended maintenance interval (1,000 hours)
• Extended run 48 hour fuel tank (150L / 39.6 US gal)
• Single point lift (without enclosure)
• Start battery and on-board battery charger
• DC output circuit breaker
• Dial-up Modem Package
• Automatic dial out pager notification on warning or fault
• Trend and Report Software for GC View
• Programmable HMI operator interface for on-site visual display of
operating parameters, alarms, shutdowns and settings and control
of ancillary site functions
Mechron Power Systems2437 Kaladar AvenueOttawa, OntarioCanada K1V 8B9
Tel: (613) 733-3855Fax: (613) 733-8197
www.mechron.com
A Division ofToromont Industries Ltd.
Product Sheet
GC Series Controllers:
DCG Series Generator Sets include
Mechron’s GC 2000 controller. The GC
2000 features a full HMI interface,
providing comprehensive controls and
safety shutdowns, including full engine
and alternator field control, automatic
start, cycling and remote control and
monitoring capability.
SPECIFICATIONS
Power Ratings 4.5 - 7 kW
Output Voltages 24 or 48 VDC, positive or negative ground
Engine Types Liquid Cooled - Kubota
Voltage Regulation +/-1%
Ripple 500 mV
Communications Protocols: TCP/IP (HTTP, custom), Modbus ASCII Connectors: RS232-DB9, Ethernet RJ45
Discrete Outputs Common Alarm AC Available Engine Running
Shutdowns Low Oil Pressure High Engine Temperature Overspeed / Underspeed Overvoltage No speed signal
Operating Temperature -40°C to +45°C (-40°F to 113°F) w/cold start package
Acoustic Noise Without Enclosure: 80 dBA @ 25 feet (7.6m)
Starting System 12 V with on-board charger
MODELS
Specification DCG4500 DCG7000
Without Enclosure
Power Output 4.5kW 7kW
Voltage Output 24 or 48V 24 or 48V
Fuel Types Diesel LPG / NG Diesel LPG / NG
Engine Kubota Z482 Kubota DF752 Kubota D722 Kubota DF752
Fuel Consumption 75% load
0.40 gal/h 1.5 L/h
29 / 66 ft3/h 0.63 gal/h
2.4 L/h 44 / 102 ft
3/h
Weight (Dry) 267 lb / 121 kg 290 lb / 132 kg 354 lb / 161 kg 354 lb / 161 kg
Dimensions (LxWxH) 35” x 25.5” x 30" 89 cm x 65 cm x 76 cm
39” x 25.5” x 30" 99 cm x 65 cm x 76 cm
Enclosure
Dimensions (LxWxH) 53” x 30” x 37" / 135cm x 76cm x 94cm
Weight 350 lb / 159 kg
Acoustic Noise With Enclosure: 67 dBA @ 25 feet (7.6m)
Mechron Power Systems2437 Kaladar AvenueOttawa, OntarioCanada K1V 8B9
Tel: (613) 733-3855Fax: (613) 733-8197
www.mechron.com
A Division ofToromont Industries Ltd.
Product Sheet
DIMENSIONS
Recommended