Controllers IR33 Manual

Preview:

Citation preview

IR33 Universal SeriesIR33 Universal controllers Applications guide

Integrated Control Solutions for Energy Savings

2

3

• IR33V7 – 1 Cool• IR33V7 – Alarm control (low temperature or high temperature)• IR33W7 – 1 Heat / 1 Cool• IR33W7 – 1 Heat / 1 Cool (heat pump)• IR33Z7 – 1 Heat / 1 Cool with alarms• IR33Z7 – 2 Heat / 2 Cool• DN33Z7 – 2 Heat / 2 Cool (heat pump)• IR33Z7 – 4 Cool• IR33Z7 – 4 Heat

Standard temperature applications 13

page

Selection matrix 5

Accessories for IR33/DN33 Universal 39

Replacement table 6

Programming instructions, parameters and alarm table 7

• IR33W7 – 2 Cool circuits• IR33E7H – 2 Heat / Modulating Cool• DN33E7H – 2 Heat / Modulating Cool• IR33E7H – Modulating 1 Heat / 1 Cool with pump call

Special temperature applications 23

• IR33V9 – 1 Humidification• IR33V9 – 1 De humidification• IR33W9 – 1 Humidification / 1 De humidification• DN33W9 – 1 Humidification / 1 De humidification

Standard humidity applications 28

• IR33V9 – 1 Stage Direct Acting Pressure• IR33Z9 – 4 Stages Direct Acting Pressure• DN33Z9 – 4 Stages Direct Acting Pressure• IR33Z9 – 4 Stages Reverse Acting Pressure

Standard pressure applications 33

Index

• DN33W9 – 1 Cool / 1 Humidification

Combined applications 37

4

5

Selection Matrix

Z

V

IR

W

0

33

7

D

A

2

One relay output

Two relay output

Four relay output

One solid state output

Four solid state output

Carel IR33 Universal Series – Part Number Guide

DN

Panel Mount

Din Rail Mount

B

E

One relay + one 0-10V output

Two relay + two 0-10V output

IR, buzzer, Real Time ClockB

R

H 115-230 Vac p. supply

IR, buzzer

L 12-24 Vac/12-30 Vdc p. supply

Temperature inputs

M 24 Vac/dc p. supply

9 Universal inputs

Selection matrix

6

Type Old Code New Code

1 relay IR32V*L000 (12-24 Vac/dc) IR33V*LR20 (12-24 Vac/dc)

2 relay IR32W*0000 (12-24 Vac/dc) IR33W*LR20 (12-24 Vac/dc)

4 relay IR32Z*0000 (12-24 Vac/dc) IR33Z*LR20 (12-24 Vac/dc)

1 SSR IR32D*L000 (12-24 Vac/dc) IR33D*LR20 (12-24 Vac/dc)

4 SSR IR32A*0000 (12-24 Vac/dc) IR33A*LR20 (12-24 Vac/dc)

1 relay + 1 x 0-10V

IR32A*L000 + 1 x CONVONOFF0 + 1 x CONVO/10A0

IR33B*H*20 (230 Vac)

2 relay + 2 x 0-10V

IR32A*0000 + 2 x CONVONOFF0 + 2 x CONVO/10A0

IR33E*H*20 (230 Vac)

Type Old Code New Code

1 relay IRDRV*0000 (24-240 Vac)DN33V**R20 (12-24 Vac/dc)

4 relay IRDRZ*0000 (12-24 Vac/dc) DN33Z*LR20 (12-24 Vac/dc)

4 SSR IRDRA*0000 (12-24 Vac/dc) DN33A*LR20 (12-24 Vac/dc)

1 relay + 1 x 0-10V

IRDRA*0000 + 1 x CONVONOFF0 + 1 x CONVO/10A0

DN33B*H*20 (230 Vac)

2 relay + 2 x 0-10V

IRDRA*0000 + 2 x CONVONOFF0 + 2 x CONVO/10A0

DN33E*H*20 (230 Vac)

DN33V*HR20 (230 Vac)

2 relay IRDRW*0000 (24-240 Vac)DN33W*LR20 (12-24 Vac/dc)

DN33W*HR20 (230 Vac)

Replacement IR32 to IR33 – Panel mount

Replacement IRDR to DN33 – Din rail mount

Note that in the new IR33 / DN33 range, every model is available with power supply 12-24 Vac/dc (or 24Vac/dc) OR 240 Vac and optional Real Time Clock. Please contact us for more details.

Replacement tables

7

Programming instructions p. 8

Parameter list p. 9

Alarm table p. 11

Programming instructions, parameters and alarm table

8

9

10

11

12

13

IR33V7 – 1 Cool p. 14

IR33V7 – Alarm control (low temp or high temp) p. 15

IR33W7 – 1 Heat / 1 Cool p. 16

IR33W7 – 1 Heat / 1 Cool (heat pump) p. 17

IR33Z – 1 Heat / 1 Cool with alarms p. 18

IR33Z7 – 2 Heat / 2 Cool p. 19

DN33Z7 – 2 Heat / 2 Cool (heat pump) p. 20

IR33Z7 – 4 Cool p. 21

IR33Z7 – 4 Heat p. 22

Standard temperature applications

14

15

16

17

18

19

20

21

22

23

IR33W7 – 2 Cool circuits p. 24

IR33E7H – 2 Heat / Modulating Cool p. 25

DN33E7H – 2 Heat / Modulating Cool p. 26

IR33E7H – Modulating 1 Heat / 1 Cool with pump call p. 27

Special temperature applications

24

25

26

27

28

IR33V9 – 1 Humidification p. 29

IR33V9 – 1 Dehumidification p. 30

IR33W9 – 1 Humidification / 1 De humidification p. 31

DN33W9 – 1 Humidification / 1 De humidification p. 32

Standard humidity applications

29

30

31

32

33

IR33Z9 – 4 Stages Direct Acting Pressure p. 34

IR33Z9 – 4 stages Reverse Acting Pressure p. 35

DN33Z9 – 4 Stages Direct Acting Pressure p. 36

Standard pressure applications

34

35

36

37

DN33W9 – 1 Cool / 1 Humidification p. 38

Combined applications

38

39

NTC probes

Other probes

1413306AXX: Brass pocket 8*60mm ¼ Gas for NTC probes.

1413309AXX: Stainless steel pocket 8*60mm ¼ Gas for NTC probes.

PTC0150000: Bulb sensor (not waterproof), 1.5m, -50 to +130°C.

SPKT00***0: Pressure probes. SPKC00*310: Cables for pressure probes.

DP*C***000: Combined humidity and temperature probes.

IROPZ48500: Serial card RS485 for IR33.

IROPZSER30: Serial card RS485 for DN33.

IRTRUES000: Remote control for IR33 and DN33 series universal.

IROPZKEY00: Programming key for IR33 (batteries).

IROPZKEYA0: Programming key for IR33 (230V).

Other accessories

Supervisory

PlantVisorPRO is a monitoring and telemaintenance system designed for medium to large size installations. Its features are: centralisation of the information from the field devices, monitoring of variables, management of alarms (through fax, SMS, emails or relay), display of detailed and complete graphs, and a lot of other functions settable according to your installation.

PlantWatchPRO is a PC-free logging and alarm solution ideal for small – medium size installations. It features a large colour touch screen, can record variables and manage alarms.

For the connection of the RS485 network, we recommend the use of the Belden 8760 cable (1 pair, 18AWG screened cable with drain wire).

Note: The pre-configuration of PlantWatchPRO and PlantVisorPRO is available. Please contact us for more information.

PP2STGSXE0: PlantVisorPRO2 Box with floating suction, parameter control and energy modules.

PWPROM0000: PlantWatchPRO with internal PSTN modem.

MODEMGSM: GSM modem for PlantWatchPRO (for SMS sending).

NTC***HP00 : NTC probe -50 to +50°C plastic IP67

NTC***WP00: NTC probe -50 to +90°C stainless steel IP68

NTC***HT00: NTC probe 0 to +150°C plastic IP55

*** lengths available: 008 = 0.8m, 015 = 1.5m, 030 = 3m, 060 = 6m, 120 = 12m.

Accessories

PP2STGSTE0: PlantVisorPRO2 Touch with floating suction, parameter control and energy modules.

40

Head Office – Sydney

Melbourne Office

Brisbane Office

PO Box 6809, Silverwater Business Ctr., NSW 1811

Ph: 02 8762 9200 Fax: 02 9764 6933

PO Box 558, Mt. Waverley, VIC 3149

Ph: 03 9550 0898 Fax: 03 9550 0878

Suite 28, Bldg 6, 2404 Logan Rd, Eight Mile Plains, QLD 4113

Ph: 07 3340 5107 Fax: 07 3341 4390

www.carel.com.au sales@carel.com.au

CAREL Australia Pty LtdA.C.N 067 528 269

IR33

univ

_A

G re

v1.4

–2

9/0

9/2

011

Recommended