Control Panels CatalogueSwimming Pool Panels
Motor Start PanelsMotor Start Panels
Cental Heating Panels
AMF ATS genset panels
Control panels Catalogue
Swimming pool panel 1 Pump 1 LightSwimming pool panel 1 Pump 2 LightS i i l l 1 P 3 Li ht
Swimming pool panel 1 Pump 4 LightSwimming pool panel 2 Pump 4 Light
Swimming pool panel 1 Pump 3 LightSwimming pool panel 2 Pump 3 Light
Swimming pool panel 2 Pump 4 LightSwimming pool panel in plastic enclosure
Swimming pool panel - WaterproofCustom design
Return to main page
Features
Number of Pumps 1
Swimming Pool panel 1Pump 1 Light
Number of Pumps 1Number of Lights 1Power of pump (HP) 1,5;2;3Power of Lights up to 400 VA/lightIn (A) 7,8,10( ) ,8, 0Imax (A) 10Icc (kA) 10Hz 50Power (kVA) 0Power (kW) 1.4V~ (V) 230V Aux (V) 0IP 53Dim. ( H x L x P ) 400x300x200 mm
Return Next Page
FeaturesSwimming Pool panel 1Pump 2 Light
Number of Pumps 1Number of Lights 2Power of Pump (HP) 1,5;2;3Power of Lights up to 400 VA/light
( ) 0 3In (A) 10,11,13Imax (A) 15Icc (kA) 10Hz 50Power (kVA) 0Power (kW) 1 7Power (kW) 1.7V~ (V) 230V Aux (V) 0IP 53Dim. ( H x L x P ) 500x400x200 mm
Return Next Page Previous page
Features
Number of Pumps 1
Swimming pool panel 1 Pump 3 Light
Number of Pumps 1Number of Lights 3Power of Pump (HP) 1,5;2;3Power of Lights up to 400 VA/lightIn (A) 12,13,15( ) , 3, 5Imax (A) 17Icc (kA) 10Hz 50Power (kVA) 0Power (kW) 2
V~ (V)230 for single phase or 400
for three phaseV Aux (V) 0IP 53Dim. ( H x L x P ) 600x400x200 mm
Return Next Page Previous page
FeaturesSwimming pool panel 2 Pump 3 Light
Number of Pumps 2Number of Lights 3Power of pump (HP) 1,5;2;3Power of Lights up to 400 VA/lightg p gIn (A) 20,21,23Imax (A) 25Icc (kA) 10Hz 50Power (kVA) 0Power (kW) 4
V~ (V)230 for single phase or 400
for three phaseV Aux (V) 0IP 53Dim ( H x L x P ) 600x400x200 mmDim. ( H x L x P ) 600x400x200 mm
Return Next Page Previous page
Features
Number of Pumps 1
Swimming pool panel 1 Pump 4 Light
Number of Pumps 1Number of Lights 4Power of Pump (HP) 1,5;2;3Power of Lights up to 400 VA/lightIn (A) 14,15,17( ) , ,Imax (A) 25Icc (kA) 10Hz 50Power (kVA) 0Power (kW) 4
V~ (V)230 for single phase or 400
for three phaseV Aux (V) 0IP 53Dim. ( H x L x P ) 600x500x200 mm
Return Next Page Previous page
Features
N b f P 2
Swimming pool panel 2 Pump 4 Light
Number of Pumps 2Number of Lights 4Power of Pump (HP) 1,5;2;3Power of Lights up to 400 VA/lightIn (A) 14 15 17In (A) 14,15,17Imax (A) 25Icc (kA) 10Hz 50Power (kVA) 0Power (kW) 4( )
V~ (V)230 for single phase or 400
for three phaseV Aux (V) 0IP 53Dim. ( H x L x P ) 600x500x200 mm
Return Next Page Previous page
Features
Number of Pumps 1
Swimming Pool panel in plastic enclosure
Number of Pumps 1Number of Lights 1Power of Pump (HP) 1,5;2;3Power of Lights up to 400 VA/lightIn (A) 7,8,10( ) , ,Imax (A) 10Icc (kA) 10Hz 50Power (kVA) 0Power (kW) 1.4V~ (V) 230V Aux (V) 0IP 53Dim. ( H x L x P ) 400x300x200 mm
Return Next Page
P iPrevious page
FeaturesSwimming Pool panel Waterproof
Number of Pumps 1Number of Lights 1 or 2Power of Pump (HP) 1,5;2;3Power of Lights up to 400 VA/lightIn (A) 7 8 10In (A) 7,8,10Imax (A) 10Icc (kA) 10Hz 50Power (kVA) 0Power (kW) 1.7Power (kW) 1.7V~ (V) 230V Aux (V) 0IP 53
Dim. ( H x L x P )400x300x200 mm 500x400x200 mm
Return Next Page
Previous page
FeaturesUpon Request, we can supply any customized solution to meet your individual requirements
Customized Panels
Panel with 8 lights 400VA and 4 pumps for swimming poolPanel with 3 pumps and water heating for swimming pool
Return Previous page
Control panels Catalogue
Direct on line starter panels: Single-Phase / Three-PhaseDirect on line starter panels: Three-Phase
Star Delta starter panelsAutotransformer starter panels
Soft Starter PanelsCustom Panels
Return
Soft Starter Panels
FeaturesDirect on line Single-Phase / Three-Phase starter panel
Number of pumps 1Power of pump (HP) 0,75;1;1,5;2In (A) 2,4;3,3;4,7;6,5Imax (A) 10I (kA) 10Icc (kA) 10Hz 50Power (kW) 0,55;0,75;1,1;1,5V~ (V) 400V Aux (V) 230IP 53IP 53Dim.(HxLxP)mm 185x101x142
Return Next Page
Features
Number of pumps 1
Direct on line Three-Phase (1 or 2 pumps) starter panel
Power of pump (HP) 0,75;1;1,5;2;3;4In (A) 1;2;2,5;2,9;4,3;5,8Imax (A) 18Icc (kA) 10Hz 50Hz 50Power (kW) 0,55;0,75;1,1;1,5;2,2;3V~ (V) 400V Aux (V) 230IP 53Dim (HxLxP)mm 500x400x200Dim.(HxLxP)mm 500x400x200
Return Next Page
Previous page
Features
Number of pumps 1
Star Delta Starter Panel
Power of pump (HP) 5,5;7,5;10;15;20;25;30
In (A) 7,2;10;13,5;20;26,9;33,7;40Imax (A) 17;25;25;32;32;45;50I (kA) 10Icc (kA) 10Hz 50Power (kVA) 0
Power (kW) 4,1;5,5;7,5;11,2;15;18,5;22V~ (V) 400V (V) 400V Aux (V) 0IP 53
Dim.(HxLxP)mm500x400x200;600x400x 200; 600x500x200
Return Next Page
Previous page
Features
Number of pumps 1Power of pump
Autotransformer Starter Panel
Power of pump (HP) 5,5;7,5;10;15;20;25;30
In (A) 7,2;10;13,5;20;26,9;33,7;40Imax (A) 17;25;25;32;32;45;50Icc (kA) 10Icc (kA) 10Hz 50Power (kVA) 0
Power (kW) 4,1;5,5;7,5;11,2;15;18,5;22V~ (V) 400V Aux (V) 0IP 53
Dim.(HxLxP)mm500x400x200;600x400x 200;600x500x200
Return Next Page
Previous page
Features
Number of pumps 1
Soft Starter Panels
Number of pumps 1Power of pump (HP) 5,5;7,5;10;15;20;25;30
In (A) 7,2;10;13,5;20;26,9;33,7;40Imax (A) 17;25;25;32;32;45;50( ) ; ; ; ; ; ;Icc (kA) 10Hz 50Power (kVA) 0
Power (kW) 4,1;5,5;7,5;11,2;15;18,5;22V~ (V) 400V Aux (V) 0IP 53
Dim. ( H x L x P )500x400x200;600x400x 200;600x500x200
Return Next Page
P iPrevious page
FeaturesUpon Request, we can supply any customized solution to meet your individual requirements
Starter for Electric Motors
Return Previous page
FeaturesCentral Heating Panels
Upon Request, we can supply any customized solution to meet your individual requirements
Return
your individual requirements
C t l l C t lControl panels Catalogue
Automatic Control PanelsAutomatic Mains Failure
Automatic Transfer SwitchReturn
ACP panels rely on the electronic boards that control the generators. The ACP Panel monitors the Mains and in the event of failure or irregular power
l i h i l h d Automatic Control Panel
supply, gives the signal to start the generator and switch the changeover to supply from the generator. Once the Main Power supply is restored, the ACP's electronic board will switch the changeover to power supply from the Mains and initiate the generator's shutdown process
Return
Next page
initiate the generator s shutdown process
AMF panels rely on electronic boards that control the generators. The AMF Panel receives a remote signal from the ATS panel to start the generator and initiates the shutdown process once the signal
Return
Next page
stops. Automatic Mains Failure
p g
Previous page
ATS panels rely on an electronic board that control the Mains and give a remote signal for the the Mains and give a remote signal for the generator to start. Once the parameters are stabilized, the ATS panel makes the changeover. Upon recovery of the Mains, the ATS Panel will changeover to the Mains for the generator's shutdown procedure.
Automatic Transfer Switch
Return
Previous page
Recommended