7/27/2019 Configurare SIAE

http://slidepdf.com/reader/full/configurare-siae 2/33

AL Compact PDH Radio

3 LAN

LCT DescriptionPART 1

Connecting to LCT – Equipment -

Connexion to LCT – Software –

PC: USB Cable

Click on Connect

7/27/2019 Configurare SIAE

http://slidepdf.com/reader/full/configurare-siae 3/33

Login to equipment

Equipment @ IP

SYSTEM

SIAEMICR 

To avoid each time to

enter Password

Connexion

Connexion from one or more IP@

from a file (See P45)

Clique on OK to accede tothe LCT software

7/27/2019 Configurare SIAE

http://slidepdf.com/reader/full/configurare-siae 4/33

PART 2

LCT Windows

Description of the Menu Bar 

From Left to Write:Connect / DisconnectConnect - Contains the commands to activate the connection with every equipment preseinto the network.Disconnect - Allows deactivating the connection.

Login

Contains the commands to activate the login with one or more remote equipment pres

into the Equipment list area.Logout

Contains the commands to deactivate the login with one or more remote equipment presinto the Equipment list area.

Refresh

Contains the commands to request the updating of the information present into Equipment list area.

7/27/2019 Configurare SIAE

http://slidepdf.com/reader/full/configurare-siae 5/33

EquipmentContains the commands to check the configuration, composition, functional status etc. ofthe equipment selected into the Equipment list area.

NetworkContains the commands for the management of the users that can use the program.

OptionContains the commands to customize the program (number of signals that can be stored

into the alarm history, connection modes and parameters, etc.).

ToolsContains the command to save, open, display, transfer a configuration file, the commandfor the management of the “remote equipment” list and the command to display themonitoring files (alarms and PM measurements) detected with the Siae Alarm &Performance Monitoring program

Menu Equipment:

Menu Equipment description

LCT Interface,

they allow opening the equipment graphical interface (Local Craft Terminal or LoOperator Manager).

Properties,

it allows checking the features (network identification code, addresses, reference date/timetc.) and executing the software reset of the equipment.

View Current Alarms,

it allows checking the current alarms.

7/27/2019 Configurare SIAE

http://slidepdf.com/reader/full/configurare-siae 6/33

Alarm Severity Config,

it allows changing the forwarding status of the alarms/trap and the seriousness lecoupled with the alarms.

View Active Manual Operation,

it allows checking the actually activated manual operations and setting the time (timeo

after which the forcing operations are automatically deactivated.History Events Realignment,

it allows realigning the information relevant to the alarms, memorized into the disk of PC and displayed into the Alarm History Log area, with the ones really present into selected equipment.

Version,

it allows checking the version and executing the updating of the equipmsoftware/firmware.

Performances,

it allows checking the list of the Performance Monitoring measurements available for tselected equipment type, the status (activated or deactivated) of each single measuremand the relevant results.

Units,

it allows checking the characteristics of the hardware that composes the equipment.

Diagnosis,

it allows running the diagnostics program which, analyzing the active alarms of the selectequipment, returns the possible causes that have triggered the alarms themselves.

Communication Setup,

it allows checking and changing the connection parameters (IP address, baud rate, routtable, OSPF parameters, etc.) used by the equipment.

IP/OSI Table Alignment,

it allows copying the elements present into the “remote element list” of the local equipmeinto the “Remote Element List” of the selected equipment.

Disable/Enable,

it allows disabling and then re-enabling again the connection of a equipment with tprogram.

Equipment Features Management, (Optional)

allows checking the functionalities (capacity and additional service channels, managemof OSPF protocol, etc.) enabled for the selected equipment.

Warning. This command is available only for equipment of PDH-AL type.

7/27/2019 Configurare SIAE

http://slidepdf.com/reader/full/configurare-siae 7/33

Equipment Inventory Report,

allows saving to file the configuration and the network parameters of the selecequipment.

PART 3LCT InterfaceTo access to the LCT Interface: Equipment LCT Interface

Interface LCT

7/27/2019 Configurare SIAE

http://slidepdf.com/reader/full/configurare-siae 8/33

Description of the higher part of the LCT interface

Channel and Frequencies Transmit and receive.

Lower Parity Higher Parity

Channel 7 Channel 7’ 

7/27/2019 Configurare SIAE

http://slidepdf.com/reader/full/configurare-siae 9/33

Configuration 1+ 0

Configuration: Equipment configuration

 

ODUIDU ODU IDU

7/27/2019 Configurare SIAE

http://slidepdf.com/reader/full/configurare-siae 10/33

Modulation / Capacity

The choice between 4,16 QAM et 8,16, 32 et 64 M Bits is made only locally 

Link ID CapacityThe choice between 4,16 QAM et 8,16, 32 et 64 M Bits s is made on remote site first and secondly locally

7/27/2019 Configurare SIAE

http://slidepdf.com/reader/full/configurare-siae 11/33

Tributary: 16x2Mbits on Equipment situated on thfront of panel de l’IDU

Tributary: Put into service one of 16x2Mbits 2 MBits

7/27/2019 Configurare SIAE

http://slidepdf.com/reader/full/configurare-siae 12/33

Click on switch to

declare the 2MBits Tributary

channel.

It decrease the

If no 2M Bitsare not

connected on

this Port 

 At nearly the same time, this action

has to be performed on Remote and  Local side,

 For this short period, the alarm De-

multiplexer will appear, and disappeared when the local and 

remote tributary shall be activated or deactivated.

7/27/2019 Configurare SIAE

http://slidepdf.com/reader/full/configurare-siae 13/33

Independent loop on 16 x 2 M Bits line side and Radiside

Radio Branch

Frequency Change only Locally

 

2M Bits

loop 

2Mbits

Radio

1) To select other 

frequency, use the lift

on the left of theWindows

Frequency to bechanged is in red

2) Click on Lock 

Channel

3) Click on Apply

7/27/2019 Configurare SIAE

http://slidepdf.com/reader/full/configurare-siae 14/33

Link Branch

Frequency Change on the link, both remote and local side with one click on local side

Radio Branch: Power Manual Mode and Automatic Mode

Automatic: ATCPThis allowed to limited the

transmit Power ²of transmitter:

-To preserve frominterferences other microwave

-To limit the consum tion

7/27/2019 Configurare SIAE

http://slidepdf.com/reader/full/configurare-siae 15/33

Radio Branch: SettingCarrier on/off. Tx on/off. Power supply on/off 

7/27/2019 Configurare SIAE

http://slidepdf.com/reader/full/configurare-siae 16/33

Configurare-LAN:

LAN 1:

7/27/2019 Configurare SIAE

http://slidepdf.com/reader/full/configurare-siae 17/33

7/27/2019 Configurare SIAE

http://slidepdf.com/reader/full/configurare-siae 18/33

7/27/2019 Configurare SIAE

http://slidepdf.com/reader/full/configurare-siae 19/33

LAN 2:

7/27/2019 Configurare SIAE

http://slidepdf.com/reader/full/configurare-siae 20/33

7/27/2019 Configurare SIAE

http://slidepdf.com/reader/full/configurare-siae 21/33

7/27/2019 Configurare SIAE

http://slidepdf.com/reader/full/configurare-siae 22/33

LAN 3:

7/27/2019 Configurare SIAE

http://slidepdf.com/reader/full/configurare-siae 23/33

7/27/2019 Configurare SIAE

http://slidepdf.com/reader/full/configurare-siae 24/33

7/27/2019 Configurare SIAE

http://slidepdf.com/reader/full/configurare-siae 25/33

INTERNAL PORT:

7/27/2019 Configurare SIAE

http://slidepdf.com/reader/full/configurare-siae 26/33

7/27/2019 Configurare SIAE

http://slidepdf.com/reader/full/configurare-siae 27/33

7/27/2019 Configurare SIAE

http://slidepdf.com/reader/full/configurare-siae 28/33

ETHERNET SWITCH:

7/27/2019 Configurare SIAE

http://slidepdf.com/reader/full/configurare-siae 29/33

Virtual-Lan configuration:

7/27/2019 Configurare SIAE

http://slidepdf.com/reader/full/configurare-siae 30/33

  Adaugare VLAN 1.

Vid = 1

 LAN 1 = Ena. Untagged 

 LAN 2 = Disable LAN 3 = Disable

 PORT 1 = Ena. Tagged 

 Apply

Adaugare VLAN 2.

Vid = 2

 LAN 1 = Disable

LAN 2 = Ena. Untagged

 LAN 3 = Disable

 PORT 1 = Ena. Tagged 

 Apply

Adaugare VLAN 3.

Vid =3

 LAN 1 = Disable LAN 2 = Disable

 LAN 3 = Ena. Untagged 

 PORT 1 = Ena. Tagged 

 Apply

7/27/2019 Configurare SIAE

http://slidepdf.com/reader/full/configurare-siae 31/33

Cum trebuie sa arate configuratia finala dupa adaugarea celor 3 Vlan-uri:

7/27/2019 Configurare SIAE

http://slidepdf.com/reader/full/configurare-siae 32/33

Ex. Configurare SIAE:

Ex. Wo IT:

Ip Management : IP 172.17.64.70,Net Mask 255.255.255.224, Def.Gw 172.17.64.65IP RAU A : IP 172.17.37.49,Net Mask 255.255.255.252

IP RAU B : IP 172.17.37.50,Net Mask 255.255.255.252Radio 1USER:SYSTEM

PASS:SIAEMICR 

Radio 1/2USER:SYSTEM

PASS:SIAEMICRO

Radio A Equipment type ALC (NMS=Q3)

1.Equipment /Properties : Radio A / Agent IP: 172.17.64.70

Comunication Setup / Port Configuration

IP Eth : 172.17.64.70

255.255.255.224

LCT PPP : 1.0.0.1

255.255.255.252

PPP RADIO : 172.17.37.49

255.255.255.252

Client

Set Values /Store

2.Comunication Setup/ Stored Routing TableRouting Table : 2.0.0.0

255.255.255.252

Next Hop 172.17.37.50 pe RadioDef.Gateway: 172.17.64.65 pe LAN

3.Tools/Subnetwork Configutaion Wizard(se foloseste pt ca A sa vada B)

New Configutation/Add Station

Add Element 1 :IP 172.17.64.70 Managed by SCTAdd Element 2 :IP 172.17.37.50 Remote Link 

Actul Configuration se bifeaza Station/Send

7/27/2019 Configurare SIAE

http://slidepdf.com/reader/full/configurare-siae 33/33

Radio B Equipment type ALC (NMS=Q3)

1. Equipment /Properties : Radio B / Agent IP: 172.17.37.50

Comunication Setup / Port Configuration

IP Eth : 10.17.1.1 ?????? nu conteaza

255.255.255.252 nu conteaza

LCT PPP : 2.0.0.1255.255.255.252

PPP RADIO : 172.17.37.50

255.255.255.252

Client

Set Values /Store

2.Comunication Setup/ Stored Routing TableRouting Table : -

Def.Gateway: 172.17.37.49 pe Radio

3.Tools/Subnetwork Configutaion Wizard(se foloseste pt ca B sa vada A)Add Station

Add Element 1 :IP 172.17.37.50 Managed by SCT

Add Element 2 :IP 172.17.64.70 Remote Link 

Actul Configuration se bifeaza Station/SendOBS.

Se reseteaza echipamentul 1-2 minute

Equipment /Comunication Setup / Port Configuration / Set Values /Store/Restart1.Equipment type ALC (NMS=Q3)

2.Equipment type AL plus (NMS=Q3 - 2porturi cu rol de switch)

View Active Manual Operation (mentenanta)

Marius Cavai- Dobresc