Computed Tomography

CT-C2000

CT-C3000

CT-C3000Dual

Proviz 8Multi-slice CT Scanner

1998

2002

1999

2000

Whole body CT scanner

Spiral CT Scanner

Dual-slice CT Scanner

2003

CT-C3000

CT Working Principle

Data acquisition Data acquisition

Image displayImage display

Reconstruction and post-processingReconstruction and post-processing

X-ray generationX-ray generation

Scanning In

terv

al

Scanning In

terv

al

Conventional ScanningConventional Scanning

◎ Scanning speed is restricted because of non-continuous scanning.

Spiral Scanning = Volume Scanning = Volume Scanning

Spiral ScanningSpiral Scanning

Working Principle of Spiral CT ScannerWorking Principle of Spiral CT Scanner

◎ Continuous rotation of X-ray tube and detectors

◎ Continuous emission of X-ray

◎ Continuous couch move-in at an even speed

◎ Continuous data acquisition

Scanning speed is increased greatly

Volume scanning

More easy to patient exam

Increase outpatient

Reduce motion artifacts

Lower dosage of enhancement medium

Reduce mechanical faults

Reduce the missed diagnosis

Image post-processing making

3D visualization into reality

Advantage of Spiral ScanningAdvantage of Spiral Scanning

+

Reduce breath and motion artifacts

◎ More easy to patient exam

Breath motionSuccessful holding breathA

dva

nta

ge

of

Sp

iral

A

dva

nta

ge

of

Sp

iral

S

can

nin

gS

can

nin

g

◎ Increase outpatient

Ad

van

tag

e o

f S

pir

al

Ad

van

tag

e o

f S

pir

al

Sca

nn

ing

Sca

nn

ing

To acquire different phases images of viscera

◎ Lower usage of enhancement medium

Artery phase Portal vein phase

Ad

van

tag

e o

f S

pir

al

Ad

van

tag

e o

f S

pir

al

Sca

nn

ing

Sca

nn

ing

Nodular pathologic changes can be displayed clearly.

◎ Thin slice scanning of large range

10mm scanning 3mm scanning

Ad

van

tag

e o

f S

pir

al

Ad

van

tag

e o

f S

pir

al

Sca

nn

ing

Sca

nn

ing

MPR 3D

Ad

van

tag

e o

f S

pir

al S

can

nin

gA

dv

anta

ge

of

Sp

ira

l Sca

nn

ing

◎ High speed

◎ Thin slice

◎ Strong capability of spiral scanning

◎ High quality images

◎ Rich functions of image processing

Advantage of CT-C3000Advantage of CT-C3000

360°/sec.

Clinical application:

◎ Volume scanning of ROI can be achieved with h

olding breath one time

◎ Reduce the missed diagnosis rate of small focu

s without interval data acquisition

◎ Reduce breath and motion artifacts

◎ Easy to acquire enhancement image

High Speed

Ad

van

tag

e o

f C

T-C

3000

Ad

van

tag

e o

f C

T-C

3000

Thickness of 1mm

Clinical Application:

Thin slice

◎ Increase diagnosis rate of small focus

◎ reconstruction with high resolution

◎ The base of 2D and 3D reconstruction

Ad

van

tag

e o

f C

T-C

3000

Ad

van

tag

e o

f C

T-C

3000

Key parts are imported from world leading manufactures.

Strong capability of spiral scanning

Continuous scanning of 80sec.

Basis

Ad

van

tag

e o

f C

T-C

3000

Ad

van

tag

e o

f C

T-C

3000

X-ray Tube

Made by VARIAN Co. of U.S.A.

Metal tube

Dual focus

◎ Special designed for spiral CT of 1 and sub-second CT scanner

◎ Large heat storage capacity: 3.5MHU

◎ High heat dispassion: 750KHU/min.Ad

van

tag

e o

f C

T-C

3000

Ad

van

tag

e o

f C

T-C

3000

Advantage of Metal TubeAdvantage of Metal Tube

Ad

van

tag

e o

f C

T-C

3000

Ad

van

tag

e o

f C

T-C

3000

◎ Large heat storage capacity, high heat dispassion

and strong capability of spiral scanning

◎ Increase images quality and extend service life of

tube with restraining electron radiation.

Advantage of metal tubeAdvantage of metal tube

Ad

van

tag

e o

f C

T-C

3000

Ad

van

tag

e o

f C

T-C

3000

Advantage of metal tubeAdvantage of metal tube

Large range continuous scanning can be achieved with 175mA and 80s.

Ad

van

tag

e o

f C

T-C

3000

Ad

van

tag

e o

f C

T-C

3000

Dual focus technique

Ad

van

tag

e o

f C

T-C

3000

Ad

van

tag

e o

f C

T-C

3000

Contrast the large focus with the small oneContrast the large focus with the small one

Large focus

Small focusAd

van

tag

e o

f C

T-C

3000

Ad

van

tag

e o

f C

T-C

3000

◎ Focus of electron beam on the a

node target is the same with heel o

n the floor.

◎ Sand blast will appear on anode

target because of small focus.

◎ Image quality will be effected.

Heel effect of focus

Ad

van

tag

e o

f C

T-C

3000

Ad

van

tag

e o

f C

T-C

3000

Made by Spellman Co.

Apply high voltage and phase controlling technology

◎ Power: 28KW

◎ Small volume and light weight

◎ Patent controlling technique

◎ Reduce noise effectively

◎ Reduce fluctuation of tube current and voltage

◎ Tube current and voltage can be controlled effectively and a

ccurately.

High voltage generatorHigh voltage generator

Ad

van

tag

e o

f C

T-C

3000

Ad

van

tag

e o

f C

T-C

3000

More……More……

Super high speed GOS detectorSuper high speed GOS detector

Slip ring and brush assembly made of silver plated copperSlip ring and brush assembly made of silver plated copper

Strong computer systemStrong computer system

Advanced system designAdvanced system design

Guarantee of high quality imageGuarantee of high quality image

Ad

van

tag

e o

f C

T-C

3000

Ad

van

tag

e o

f C

T-C

3000

Detector

◎ Made by Hamamatsu Co. of Japan

◎ Super high speed GOS solid detectorSuper high speed GOS solid detector

◎ Channel number: 688

Guarantee of high quality imageGuarantee of high quality image

Ad

van

tag

e o

f C

T-C

3000

Ad

van

tag

e o

f C

T-C

3000

◎ Images acquired from high-speed and long-time spiral sca

nning are much better than that of other materials.

Super high speed GOS detectorSuper high speed GOS detector

◎ Stand for the most leading level of t

he world

◎ X-ray absorptivity:99.98%

◎ Response speed: 40% higher than t

hat of other materials

◎ Extra-short afterglow effect

Ad

van

tag

e o

f C

T-C

3000

Ad

van

tag

e o

f C

T-C

3000

Made by Litton Co.

Silver plated copperSilver plated copper

Slip ring and brush assemblySlip ring and brush assembly

◎ Signals are transmitted accurately in real time.

◎ High stability and wearability

◎ 2000000 times is guaranteed by Litton Co..

◎ Low cost maintenance

Guarantee of high quality imageGuarantee of high quality image

Ad

van

tag

e o

f C

T-C

3000

Ad

van

tag

e o

f C

T-C

3000

Strong computer systemStrong computer system

Open workstation with Pentium IV multi-CPU

◎ Multi-task can be processing in parallel mode.

◎ Image reconstruction with high speed

◎ Huge capacity of image storage

◎ Easy to upgrade and low cost of maintenanc

e

1sec.

120000 images

Guarantee of high quality imageGuarantee of high quality image

Ad

van

tag

e o

f C

T-C

3000

Ad

van

tag

e o

f C

T-C

3000

◎ Main frequency: 2.0G

◎ Memory: 512MB

◎ Hard disk: 80GB

◎ Multi-medium of storage: 1.3GB MO disk,external hard disk,CD-

R

◎ Monitor: 21″ real-flat high resolution color monitor Ad

van

tag

e o

f C

T-C

3000

Ad

van

tag

e o

f C

T-C

3000

Computer system

Rich functions of image processing

Rich functions of image processing

◎ Strong development capability of our company

◎ Multi-arithmetic application

◎ Comprehensive image post-processing

◎ High quality images

◎ BHC technology

◎ VAC technology

◎ MAC technology

◎ Adaptive steak artifacts reduction software

◎ High resolution scanning technology

◎ MAR software

◎ Lung enhancement software

◎ Advanced noise reduction software

Magic of software

AfterBefore( 5mm)

Mag

ic o

f so

ftw

are

MAC

Mag

ic o

f so

ftw

are

Lung enhancement

Mag

ic o

f so

ftw

are

Inner ear

Mag

ic o

f so

ftw

are

◎ MPR

◎ CMPR

◎ SSD

◎ VR

◎ VE

◎ MIP/MINP

◎ CTA

3D Technology

Mag

ic o

f so

ftw

are

MPRMPR

Mag

ic o

f so

ftw

are

MPRMPR

Mag

ic o

f so

ftw

are

CMPRCMPR

Mag

ic o

f so

ftw

are

MIPMIP

Mag

ic o

f so

ftw

are

SSDSSD

Mag

ic o

f so

ftw

are

VEVE

VRVR

Mag

ic o

f so

ftw

are

Friendly operating interfaces

Human-friendly Design

◎ Presetting protocols

◎ Scanning can be completed automatically.

Clear operation steps

Hu

man

-fri

end

ly D

esig

n

Equipped with remote controlling

◎ 70cm gantry aperture

◎ 25°gantry tilt

◎ Load capacity of couch is 200Kg

◎ Clear voice prompt

Comfortable

Hu

man

-fri

end

ly D

esig

n

CT-C3000DualCT-C3000Dual

2 images can be acquired in 360°/Sec.

Ad

van

tag

e o

f D

ual

-sli

ce C

T s

can

ner Scanning speed doubled

High speed scanning

◎ Easy to patient exam, reduce breath and motion artifacts

Ad

van

tag

e o

f D

ual

-sli

ce C

T s

can

ner

Breath artifacts

Successful holding breathAd

van

tag

e o

f D

ual

-sli

ce C

T s

can

ner

Three phase scanning of liver

Scanning range: 20cm

Slice thickness: 10mm

20 cm

Spiral CT scanner

Artery phase: 20seconds

Dual-slice spiral scanning

Artery phase : 10seconds

Best continuous enhancement: about 10seconds

High speed scanning

◎ Multi-organ multi-phase images acquired accurately

Ad

van

tag

e o

f D

ual

-sli

ce C

T s

can

ner

High speed scanning

Artery Portal vein phase

Ad

van

tag

e o

f D

ual

-sli

ce C

T s

can

ner

High speed scanning

◎ Lower dosage of enhancement medium

Spiral CT: 20s,60ml Dual-slice CT: 10s,40ml

Ad

van

tag

e o

f D

ual

-sli

ce C

T s

can

ner

High speed scanning

◎ Reduce exam time

Ad

van

tag

e o

f D

ual

-sli

ce C

T s

can

ner

Image quality has been increased greatly

◎ Large rang continuous thin thickness scanning as regular scanning

Ad

van

tag

e o

f D

ual

-sli

ce C

T s

can

ner

◎ Increase the detectable rate of small pathological changes

2mm scanning10mm scanning

Small nodus focus of lungAd

van

tag

e o

f D

ual

-sli

ce C

T s

can

ner

◎ High quality images of coronal and median MPR

Spiral CT: 5mm MPR

Ad

van

tag

e o

f D

ual

-sli

ce C

T s

can

ner

Dual-slice CT: 1mm MPRAd

van

tag

e o

f D

ual

-sli

ce C

T s

can

ner

◎ Large range MRA can be acquired perfectly.

Spiral CT: 5mm

Dual-slice CT: 2mm

Adv

anta

ge o

f D

ual-s

lice

CT

sca

nner

◎ 3D image quality has been increase greatly.

Ad

van

tag

e o

f D

ual

-sli

ce C

T s

can

ner

Reduce running cost

◎ prolong use life of X-ray tube

Reduce scanning time

Increase X-ray efficiency

→Reduce exposure time→Reduce tube loading

Ad

van

tag

e o

f D

ual

-sli

ce C

T s

can

ner

CT

-C30

00D

ual

CT

-C30

00D

ual

◎ Large heat capacity metal tube of 4MHU supplied by VARIAN

◎ Special high voltage generator of 28kW supplied by SPELLMAN

◎ Super high speed GOS detectors with 10mm dual-slice

◎ Slip ring and brush assembly with 2000000 times guaranteed

◎ Two images acquired in 1sec./360°

◎ Spiral scanning with continuous 80sec.

◎ Min. Thickness: 1mm

◎ Image reconstruction time:0.8sec.CT

-C30

00D

ual

CT

-C30

00D

ual

Recommended