View
215
Download
0
Category
Preview:
Citation preview
Cleanit® EC for water treatment
No magic. Just nature.
The green way Organics removal
Heavy metal removal
Fluoride removal
Radioactive isotope removal
Arsenic removal
Simple, affordable and flexible100% green technology
Disinfection
2
No magic
Cleanit® EC is a groundbreaking water treatment
technology based on electrocoagulation. It uses
uniquely engineered electrodes capable of removing
multiple contaminants from water and wastewater.
These contaminants include multiple heavy metals,
organics, fluoride, arsenic, radioactive isotopes and
even pathogens. The functional units of the electrodes
are highly porous iron particles combined with several
proprietary functional components.
100% green, simple and cost-efficient
Cleanit® EC efficiently separates and removes
contaminants from water. No hazardous byproducts are
generated during the process and no chemical additives
are required. The technology can be applied to a wide
variety of water and wastewater treatment.
Double efficiency, half the cost
If you already use electrocoagulation for wastewater
treatment, we can easily double your process efficiency
while cutting the cost in half. How? You only need
to replace your current electrodes with Cleanit® EC
electrodes and follow the recommended operation. If you
are new to electrocoagulation, we will gladly help you set
up a test unit completely free of charge.
Power of Powder®
Cleanit® EC is developed and patented by Höganäs AB, a
world leader in iron powder established in 1797. We have
more than 1,400 customers in 65 countries and offer over
1,500 products from 14 production centers around the world.
We are driven by innovation. By utilizing the endless
opportunities of our metal powders, we want to improve
resource efficiency and lead a wave of change for the
better. That is what we call Power of Powder®.
Imagine an effective, low-cost, low- energy and low-maintenance process to treat industrial wastewater. Impossible? Not if you let nature do its magic.
to clean wastewater
Tannery and microelectronics are two examples of industries that can benefit from water purification using Cleanit® EC.Simple, affordable and flexible100% green technology
3
Cleanit® EC is an innovative and 100% green electrocoagulation technology. Developed by Höganäs, it completely revolutionizes water and wastewater treatment. Cleanit® EC efficiently removes multiple contaminants such as heavy metals, organics, fluoride, arsenic, radioactive isotopes, pathogens, etc. from water and wastewater, while lowering energy consumption and operating costs.
A green revolution in water purification
Electrocoagulation – the basics
Electrocoagulation is a simple and effective method of
removing various heavy metals, metalloids, organic
substances, ammonia, nitrates, phosphates, etc. from
contaminated water. The process is performed by
applying an electric current across metal electrodes that
are submerged in water. When the electricity passes
through the electrodes, metal ions are released from the
sacrificial anode and combine with hydroxide ions
produced at the cathode. This results in the formation of
polymeric metal hydroxides, which are excellent
coagulants. These coagulants trap and remove
contaminants present in the water. Basic concept of
electrocoagulation is schematically presented in Figure 1.
Unique electrode design
Generally, iron and aluminum are the electrodes of choice as
they form effective coagulants. What makes Cleanit® EC
unique is the design of the electrodes. They are
fabricated using proprietary powder metal technology
and additives, which can be customized to target a
specific or broad range of contaminants in water.
Because of the unique characteristics of these metal
Fig. 1. Schematic of electrocoagulation process mechanism.
Fig. 2. Cylindrical electrode with conductive rod and ring
components for smaller treatment units (left); plate electrodes
for larger treatment units (right).
powders, the Cleanit® EC electrodes have very high
surface area to volume ratio. As a result, ionization
efficiency is higher, making the electro-coagulation
process fast and energy-efficient.
An added benefit is that the design of the electrodes is
fully flexible and their composition and shape can be
customized depending on the need of treatment (as
shown in Figure 2).
Power Source
M(OH)x (precipitates)
HO-
H2O
AN
OD
E
CA
TH
OD
E
H+
Mx+
4
Chromium removal from wastewater
Hexavalent chromium contaminated wastewater obtained from Brazil
was used for the study. Table 1 briefly summarizes the wastewater
characteristics. Current density of 100 Amp/m2 was applied to the
electrodes. Figure 3 shows the results of the study. After the treatment,
hexavalent chromium was reduced to non-detect and trivalent chromium
was less than 0.01 ppm in the treated water.
Table 1. Influent wastewater characteristics
Fig. 3. Concentrations of chromium species in influent and
effluent of Cleanit® EC unit.
PARAMETER VALUE
Total Chromium (mg/L) 3,875
Hexavalent Chromium (mg/L) 3,390
Trivalent Chromium (mg/L) 485
pH 3.53
Conductivity (mS/cm) 6.20
No doubt, Cleanit is the best solution for Cr(VI) treatment.The pilot went very well, with incredibly low energy consumption and extreme efficiency.”“Quote from a customer
10 4
10 3
10 2
10
1
0.1
0Total Cr
mg/L
Cr (VI) Cr (III)
Influent
Effluent
5
A win-win partnershipPilot installation at zero cost
We offer to install a pilot plant at your site completely
free of charge. This eliminates any financial risks and
makes it possible for you to evaluate the performance
of Cleanit® EC without any long-term commitment.
The pilot test usually runs for 90-120 days with our
full technical assistance.
Complete solution at a pre-agreed price
If you are satisfied with the pilot plant performance,
Höganäs offers to design and install a complete unit at
a pre-agreed price, paid after the performance has been
approved. Höganäs provides all necessary engineering
support for the process along with any technical support
and training needed.
Our goal is to create successful and lasting relationships with our customers. That is why we not only provide you a simple, cost-efficient and 100% green solution but also offer a zero-cost and zero-obligation Cleanit® EC test module. We provide all the resources.
Example of pilot installation of Cleanit® EC.
6
Full-scale operationPre-agreed price after approval
of performance
Pilot plantZero cost to customer
FutureShared responsibility
according to individual
agreement
• Innovative and powder metallurgy-based
electrodes design
• Large electrode surface area enables
enhanced electrochemical reactions
• Effective for a broad range of contaminants
• The process is scalable and can be optimized
(batch or continuous flow)
• The process can be made selective
to target contaminants
• Minimal electrode material and
energy consumption
• Easy electrode recharging
Cleanit® EC in short
Are you already using electrocoagulationfor wastewater treatment?We offer to replace your current electrodes with Cleanit® EC free of charge. Discover how you can easily double
the efficiency of the process while cutting costs in half. If you’re satisfied with the solution, Höganäs offers to
upgrade your process at a pre-agreed price, paid after the performance has been approved.
Want to know more? Contact your nearest Höganäs office. You will find all contact details at www.hoganas.com/cleanit
7
Metal powder technology has the power to open up a world
of possibilities. The inherent properties of metal powders provide
unique possibilities to tailor solutions to match your requirements.
This is what we call Power of Powder®, a concept to constantly
widen and grow the range of metal powder applications.
With its leading position in metal powder technology, Höganäs
is perfectly placed to help you explore those possibilities as your
application project partner.
To find out how you can apply the Power of Powder®, please
contact your nearest Höganäs office.
Power of Powder®
© H
ögan
äs A
B (P
ubl.)
, Dec
embe
r 20
15.
109
3HO
G
www.hoganas.com/cleanit
Sweden
Brazil
China
France
Germany
India
Italy
Japan
Rep. of Korea
Russia
Spain
Taiwan
United Kingdom
United States
Höganäs ABHöganäsPhone +46 42 33 80 00info@hoganas.com
Höganäs Brasil LtdaMogi das CruzesPhone +55 11 4793 7711brazil@hoganas.com
Höganäs (China) Co. LtdShanghai Phone +86 21 670 010 00china@hoganas.com
Höganäs France S.A.S.LimasPhone +33 474 02 97 50france@hoganas.com
Höganäs GmbHDüsseldorfPhone +49 211 99 17 80germany@hoganas.com
Höganäs India Pvt LtdPune Phone +91 20 66 03 01 71india@hoganas.com
Höganäs Italia S.r.l.Rapallo (Genoa)Phone +39 0185 23 00 33italy@hoganas.com
Höganäs Japan K.K.Tokyo Phone +81 3 3582 8280japan@hoganas.com
Höganäs Korea LtdSeoul Phone +82 2 511 43 44korea@hoganas.com
Höganäs East Europe LLCSaint PetersburgPhone +7 812 334 25 42russia@hoganas.com
Höganäs Ibérica S.A.MadridPhone +34 91 708 05 95spain@hoganas.com
Höganäs Taiwan LtdTaipei Phone +886 2 2543 1618taiwan@hoganas.com
Höganäs (Great Britain) LtdTonbridge, Kent Phone +44 1732 377 726uk@hoganas.com
North American Höganäs, Inc.Hollsopple: PAPhone +1 814 479 3500info@nah.com
Recommended