View
224
Download
0
Category
Preview:
Citation preview
CEILING/WALL PANELS
www.jakdor.co.uk • Tel: +44 (0)1922 7111852
CEILING/WALL PANELS
www.jakdor.co.uk • Tel: +44 (0)1922 7111852
CEILING/WALL PANELS
JAKDOR is a leading supplier of wall and ceiling access panels. By using innovative design methods and processes, we provide a full range of access panels for internal and external uses. Available in standard sizes or custom made to suit individual requirements.
Fire Rated, Acoustic, Airtight and Loft Panels are also available, together with SRH Roof Hatches and Zip Retractable Ladders.
JAKDOR access panels are designed to fit into any type of ceiling/wall system, allowing easy access into the ceiling void/wall cavity where services, controls, need to be quickly accessed for maintenance or emergency measures.
Three main options are available as standard in both non-fire rated and fire rated:
• JAK.MD.PF – Combines a flush metal door with a 25mm wide picture frame.
• JAK.MD.BF – Combines a flush metal door with a concealed beaded frame.
• JAK.PB.BF – Combines a plasterboard-clad door with a concealed beaded frame for use within plasterboard wall and ceiling systems.
The access panel frame surround enables the panel to be inserted directly into a clear structural opening and screw-fixed into position through the side of the panel frame.
Manufactured from 1.2mm and 1mm Zintec steel, with a polyester powder coating of matt white RAL 9010 20% gloss (other colours available upon request). Each panel type has a removable door and is secured using a budget lock as standard. Alternative locking options are available upon request (see locking options).
We also offer an economy range of access panels (see pages 10 & 11).
HOW TO ORDER1) Establish the required frame size.
2) Specify code type eg. JAK.MD.PF., indicating hinged side (if not square) and quantity.
3) Indicate locking option.
4) If required panel is to be fire rated specify code with additional FR60 eg. JAK.MD.PF/FR60.
5) Specify alternative operation if required. Above applies to standard range only, for economy version, see appropriate details.
12
BUDGET LOCK
5mm DIAMETER FIXING HOLES
AIR SEAL 50mmO/ALL FRAME
CONTINUOUSHINGE
METAL DOOR TRAY & FRAMEPOLYESTER POWDER COATED
OPEN
TEE KEY
PLASTIC DOMEPLUG & COLLAR
25mm WIDEPICTURE FRAME
25
CLEAR OPENING WITH DOOR REMOVED= O/A PANEL FRAME LESS 24
12STRUCTURAL OPENING + 5mm LARGER THAN PANEL SIZE
CEILING/WALL PANELS
www.jakdor.co.uk • Tel: +44 (0)1922 711185 3
CEILING/WALL PANELS
www.jakdor.co.uk • Tel: +44 (0)1922 711185 3
CEILING/WALL PANELS
Page 4 JAK.MD.PF - Standard metal door with 25mm wide picture frame. 5 JAK.MD.PF. FR60/120 - Fire rated metal door with 25mm wide picture frame. 6 JAK.MD.BF - Standard metal door with concealed beaded frame. 7 JAK.MD.BF/FR60/120 - Fire rated metal door with concealed beaded frame. 8 JAK.PB.BF - Standard plasterboard door with concealed beaded frame. 9 JAK.PB.BF/FR60/120 - Fire rated plasterboard door with concealed beaded frame. 10 JAK.MD.PF.B1 - Budget metal door with 25mm wide picture frame. 11 JAK.MD.BF.B2 - Budget metal door with concealed beaded frame. 12 JAK.CTD - Ceramic Tiled Faced door. 13 JAK.CTD/FR60/120 - Ceramic Tiled Faced Fire Rated Panel. 14 JAK.CTD/B1 Budget Ceramic Tiled Faced. 15 JAK.PLAS - Plastic Access Panel Range. 16 JAK.LOFT.PF - Loft hatch with 25mm wide picture frame. 17 JAK.LOFT.PF/FR60 - Fire Rated Loft hatch with 25mm wide picture frame. 18 JAK.LOFT.BF - Loft hatch with concealed beaded frame. 19 JAK.LOFT.BF/FR60 - Fire Rated Loft hatch with concealed beaded frame. 20 JAK.CIRC.PF - Circular Access Panel with metal door and 25mm wide picture frame. 21 JAK.CIRC.BF - Circular Access Panel with metal door and concealed beaded frame. 22 JAK.EXP - Access Panel for Exposed Grid lay-in systems. 23 JAK.CON - Access Panel for Concealed Grid lay-in systems 24 Accessories and Installation. 25 Locking Options. 26 JAK.PLAS - Fitting Instructions. 27 Fitting Instructions. 28 SRH Roof Hatch. 29 SRH Roof Hatch Features. 30 ZIP Retractable Ladders. 31 BioCote.
Jakdor are continually improving and updating their product range, therefore reserve the right to modify any of their products without prior notice. If a particular type of access panel is required which does not appear to be covered by the above range, please contact our technical sales department for advice.
CONTENTS
CEILING/WALL PANELS
www.jakdor.co.uk • Tel: +44 (0)1922 7111854
CEILING/WALL PANELS
www.jakdor.co.uk • Tel: +44 (0)1922 7111854
CEILING/WALL PANELS
DimensionsPlease note that on installation of the access panel, the actual size of the structural opening in the ceiling/wall needs to be 5mm larger than the overall panel size eg. Structural opening for 600 x 600 would need to be 605 x 605 (See sizes below). Non standard sizes are available upon request, please contact our sales department.
Locking options (See page 27)
STANDARD PANELJAK.MD.PFSpecificationManufactured from 1.2mm and 1mm Zintec Steel, with a polyester powder coating of matt white RAL 9010 20% gloss (other colours available upon request). The flush metal door has a concealed continuous hinge and is secured using a standard budget lock.
FireThis is a non-fire rated access panel. For fire rated panels refer to panel type JAK.MD.PF/FR60/120.
Section view
Three -way locking
Quarter turn lock
Key lock Tamper-prooflock
Budget lockSTANDARD
Touchcatch
JAK.MD.PF access panel is designed to fit into any type of ceiling/wall system allowing easy access into the cavity/void.A 25mm wide picture frame surround is provided. This enables the panel to be inserted directly into the clear structural opening and screw-fixed into position through the side of the panel frame.
Standard metal door & picture frame
12
BUDGET LOCK
5mm DIAMETER FIXING HOLES
AIR SEAL 50mmO/ALL FRAME
CONTINUOUSHINGE
METAL DOOR TRAY & FRAMEPOLYESTER POWDER COATED
OPEN
TEE KEY
PLASTIC DOMEPLUG & COLLAR
25mm WIDEPICTURE FRAME
25
CLEAR OPENING WITH DOOR REMOVED= O/A PANEL FRAME LESS 24
12STRUCTURAL OPENING + 5mm LARGER THAN PANEL SIZE
CEILING/WALL PANELS
www.jakdor.co.uk • Tel: +44 (0)1922 711185 5
CEILING/WALL PANELS
www.jakdor.co.uk • Tel: +44 (0)1922 711185 5
CEILING/WALL PANELS
FIRE RATED PANELJAK.MD.PF/FR60/120SpecificationManufactured from 1.2mm and 1mm Zintec Steel, with polyester powder coating of matt white RAL 9010 20% gloss. The flush metal door has a concealed continuous hinge and is secured using a three-way locking system.
FireThe JAK.MD.PF/FR60/120 has been successfully tested to give up to 1 Hour Integrity in a ceiling system and 2 Hours for a wall system. All in accordance with EN1634, part 1:2000. Fire doors have intumescent strips fitted on the frames. DO NOT interfere with these seals.
Section view
DimensionsPlease note that on installation of the access panel, the actual size of the structural opening in the ceiling/wall needs to be 5mm larger than the overall panel size eg. Structural opening for 600 x 600 would need to be 605 x 605 (See sizes below). Non standard sizes are available upon request, please contact our sales department.
Locking options (See page 27)
JAK.MD.PF/FR60/120 is a fire rated access panel designed to fit into any type of fire rated ceiling/wall system allowing easy access into the cavity/void. A 25mm wide picture frame surround is provided. This enables the panel to be inserted directly into the clear structural opening and screw/bolt-fixed into position through the side of the panel frame.
Fire rated metal door & picture frame
Three -way lockingSTANDARD
Quarter turn lock
Key lock Tamper-prooflock
12
3-WAY LOCKINGSYSTEM
INTUMESCENTSEAL
PLASTIC DOMEPLUG & COLLAR OPEN
METAL DOOR TRAY & FRAMEPOLYESTER POWDER COATED
5mm DIAMETER COUNTERSUNKFIXING HOLE
CONTINUOUS HINGE WELDED TODOOR TRAY & BOLTED TO FRAME
54mmO/ALL FRAME
CLEAR OPENING WITH DOOR REMOVED= O/A PANEL FRAME LESS 24
STRUCTURAL OPENING + 5mm LARGER THAN PANEL SIZE
TEE KEY
12
CEILING/WALL PANELS
www.jakdor.co.uk • Tel: +44 (0)1922 7111856
CEILING/WALL PANELS
www.jakdor.co.uk • Tel: +44 (0)1922 7111856
CEILING/WALL PANELS
STANDARD PANELJAK.MD.BFSpecifi cationManufactured from 1.2mm and 1mm Zintec Steel, with polyester powder coating, matt white RAL 9010 20% gloss. The fl ush metal door has a concealed continuous hinge and is secured using a standard budget lock.
FireThis is a non-fi re rated access panel. For fi re rated panels refer to panel type JAK.MD.BF/FR60/120.
Section view
Three -way locking
Quarter turn lock
Key lock Tamper-prooflock
Budget lockSTANDARD
TouchCatch
JAK.MD.BF access panel is designed to fi t into any type of plasterboard ceiling/wall system allowing easy access into the cavity/void.A concealed beaded frame surround is provided to be taped and skimmed on site. This enables the panel to be inserted directly into the clear structural opening and screw-fi xed into position through the side of the panel frame.
Standard metal door & concealed beaded frame
DimensionsPlease note that on installation of the access panel, the actual size of the structural opening in the ceiling/wall needs to be 5mm larger than the overall panel size eg. Structural opening for 600 x 600 would need to be 605 x 605 (See sizes below). Non standard sizes are available upon request, please contact our sales department.
Locking options (See page 27)
12
BUDGET LOCK
TEE KEY
5mm DIAMETER FIXING HOLESAIR SEAL
CONTINUOUS HINGE
METAL DOOR TRAY & FRAMEPOLYESTER POWDER COATED
OPENPLASTIC DOME
PLUG & COLLAR
25mm WIDE BEADEDPERFORATED FLANGE
50mm O/ALL FRAME
25
CLEAR OPENING WITH DOOR REMOVED= O/A PANEL FRAME LESS 24
12STRUCTURAL OPENING + 5mm LARGER THAN PANEL SIZE
CEILING/WALL PANELS
www.jakdor.co.uk • Tel: +44 (0)1922 711185 7
CEILING/WALL PANELS
www.jakdor.co.uk • Tel: +44 (0)1922 711185 7
CEILING/WALL PANELS
DimensionsPlease note that on installation of the access panel, the actual size of the structural opening in the ceiling/wall needs to be 5mm larger than the overall panel size eg. Structural opening for 600 x 600 would need to be 605 x 605 (See sizes below). Non standard sizes are available upon request, please contact our sales department.
Locking options (See page 27)
FIRE RATED PANELJAK.MD.BF/FR60/120Specifi cationManufactured from 1.2mm and 1mm Zintec Steel, with polyester powder coating of matt white RAL 9010 20% gloss (other colours available upon request). The fl ush metal door has a concealed continuous hinge and is secured using a three-way locking system.
FireThe JAK.MD.PF/FR60/120 has been successfully tested to give up to 1 Hour Integrity in a ceiling system and 2 Hours for a wall system. All in accordance with EN1634, part 1:2000. Fire doors have intumescent strips fi tted on the frames. DO NOT interfere with these seals.
Section view
JAK.MD.BF/FR60/120 is a fi re rated panel designed to fi t into any type of fi re rated plasterboard ceiling/wall system allowing easy access into the cavity/void.A concealed beaded frame surround is provided to be taped and skimmed on site. This enables the panel to be inserted directly into the clear structural opening and screw/bolt-fi xed into position through the side of the panel frame.
Fire rated metal door & concealed beaded frame
Three -way lockingSTANDARD
Quarter turn lock
Key lock Tamper-prooflock
12 12
3-WAY LOCKINGSYSTEM
PLASTIC DOMEPLUG & COLLAR
5mm DIAMETER COUNTERSUNKFIXING HOLE
OPEN
METAL DOOR TRAY & FRAMEPOLYESTER POWDER COATED CONTINUOUS HINGE WELDED TO
DOOR TRAY & BOLTED TO FRAME
54mmO/ALL FRAME
25mm WIDE BEADEDPERFORATED FLANGE
CLEAR OPENING WITH DOOR REMOVED= O/A PANEL FRAME LESS 24
STRUCTURAL OPENING + 5mm LARGER THAN PANEL SIZE
TEE KEY
INTUMESCENTSEAL
CEILING/WALL PANELS
www.jakdor.co.uk • Tel: +44 (0)1922 7111858
CEILING/WALL PANELS
www.jakdor.co.uk • Tel: +44 (0)1922 7111858
CEILING/WALL PANELS
DimensionsPlease note that on installation of the access panel, the actual size of the structural opening in the ceiling/wall needs to be 5mm larger than the overall panel size eg. Structural opening for 600 x 600 would need to be 605 x 605 (See sizes below). Non standard sizes are available upon request, please contact our sales department.
Locking options (See page 27)
STANDARD PANELJAK.PB.BFSpecifi cationManufactured from 1.2mm and 1mm Zintec Steel, with a polyester powder coating of matt white RAL 9010 20% gloss (other colours available upon request). The recessed metal door has a factory fi tted plasterboard infi ll with a beaded edge detail, and comes complete with concealed hinges and is secured using a standard budget lock.
FireThis is a non-fi re rated access panel. For fi re rated panels refer to panel typeJAK.PB.BF.FR60/120.
Section view
Three -way locking
Budget lockSTANDARD
JAK.PB.BF access panel is designed to fi t into any type of plasterboard ceiling/wall system allowing easy access into the cavity/void.A concealed beaded frame surround is provided on the door and panel frame which allows the panel to be taped and skimmed on site. The panel is inserted directly into the clear structural opening and screw-fi xed into position through the side of the panel frame.
Standard plasterboard door & concealed beaded frame
15
OPEN
15
BUDGETLOCK
CLEAR OPENING WITH DOOR REMOVED = O/A PANEL FRAME LESS 30
80mm O/ALL FRAME
PANEL HINGE
25mm WIDE BEADED SURROUND ONFRAME & DOOR
PLASTERBOARD INFILL
TEE KEY
METAL SCREW BUNG WITHRECESSED SQUARE HOLE TOTAKE TEE KEY
AIR SEALAIR SEAL
5mm DIAMETER FIXING HOLE
METAL DOOR TRAY & FRAMEPOLYESTER POWDER COATED
STRUCTURAL OPENING + 5mm LARGER THAN PANEL SIZE
CEILING/WALL PANELS
www.jakdor.co.uk • Tel: +44 (0)1922 711185 9
15
OPEN
15CLEAR OPENING WITH DOOR REMOVED = O/A PANEL FRAME LESS 30
80mm O/ALL FRAME
PANEL HINGE
25mm WIDE BEADEDSURROUND ON FRAME & DOOR
FIRE RATEDPLASTERBOARD INFILL
TEE KEY
METAL SCREW BUNG WITHRECESSED SQUARE HOLE TOTAKE TEE KEY
5mm DIAMETER FIXING HOLE
METAL DOOR TRAY & FRAMEPOLYESTER POWDER COATED
STRUCTURAL OPENING + 5mm LARGER THAN PANEL SIZE
INTUMESCENTSEAL
INTUMESCENTSEAL
3-WAY LOCKING
CEILING/WALL PANELS
www.jakdor.co.uk • Tel: +44 (0)1922 711185 9
CEILING/WALL PANELS
DimensionsPlease note that on installation of the access panel, the actual size of the structural opening in the ceiling/wall needs to be 5mm larger than the overall panel size eg. Structural opening for 600 x 600 would need to be 605 x 605 (See sizes below). Non standard sizes are available upon request, please contact our sales department.
Locking options (See page 27)
FIRE RATED PANELJAK.PB.BF/FR60/120Specifi cationManufactured from 1.2mm and 1mm Zintec Steel, with a polyester powder coating of matt white RAL 9010 20% gloss (other colours available upon request). The recessed metal door has a factory fi tted plasterboard infi ll with a beaded edge detail, and comes complete with concealed hinges and is secured using a three-way locking system.
FireThe JAK.MD.PF/FR60/120 has been successfully tested to give up to 1 Hour Integrity in a ceiling system and 2 Hours for a wall system. All in accordance with EN1634, part 1:2000. Fire doors have intumescent strips fi tted on the frames. DO NOT interfere with these seals.
Section view
JAK.PB.BF/FR60/120 is a fi re rated panel designed to fi t into any type of fi re rated plasterboard ceiling/wall system allowing easy access into the cavity/void.A concealed beaded frame surround is provided on the door and panel frame which allows the panel to be taped and skimmed on site. The panel is inserted directly into the clear structural opening and screw/bolt-fi xed into position through the side of the panel frame.
Fire rated plasterboard door & concealed beaded frame
Three-way lockingSTANDARD
CEILING/WALL PANELS
www.jakdor.co.uk • Tel: +44 (0)1922 71118510
CEILING/WALL PANELS
www.jakdor.co.uk • Tel: +44 (0)1922 71118510
CEILING/WALL PANELS
DimensionsPlease note that on installation of the access panel, the actual size of the structural opening in the ceiling/wall needs to be 5mm larger than the overall panel size eg. Structural opening for 600 x 600 would need to be 605 x 605 (See sizes below). Non standard sizes are available upon request, please contact our sales department.
Locking options (See page 27)
BUDGET PANELJAK.MD.PF/B1SpecificationManufactured from 1mm Zintec Steel, with polyester powder coating of matt white RAL 9010 20% gloss. The flush metal door has a pin hinge and is secured using a quarter turn cam lock (other locks available upon request).
FireThis is a non-fire rated access panel.
Section view
JAK.MD.PF/B1 budget access panel is designed to fit into any type of ceiling/wall system allowing easy access into the cavity/void.A 25mm wide picture frame surround is provided. This enables the panel to be inserted directly into the clear structural opening and screw-fixed into position through the side of the panel frame.
Budget metal door & picture frame
Quarter turnlock
STANDARD
Key lock Touch catchBudget lock
CEILING/WALL PANELS
www.jakdor.co.uk • Tel: +44 (0)1922 711185 11
CEILING/WALL PANELS
www.jakdor.co.uk • Tel: +44 (0)1922 711185 11
CEILING/WALL PANELS
BUDGET PANELJAK.MD.BF/B2Specifi cationManufactured from 1mm Zintec Steel, with polyester powder coating of matt white RAL 9010 20% gloss. The fl ush metal door has a pin hinge and is secured using a quarter turn cam lock (other locks available upon request).
FireThis is a non-fi re rated access panel.
Section view
JAK.MD.BF/B2 budget access panel is designed to fi t into any type of plasterboard ceiling/wall system allowing easy access into the cavity/void.A concealed beaded frame surround is provided on the door and panel frame which allows the panel to be taped and skimmed on site. The panel is inserted directly into the clear structural opening and screw-fi xed into position through the side of the panel frame.
Budget metal door & concealed beaded frame
DimensionsPlease note that on installation of the access panel, the actual size of the structural opening in the ceiling/wall needs to be 5mm larger than the overall panel size eg. Structural opening for 600 x 600 would need to be 605 x 605 (See sizes below). Non standard sizes are available upon request, please contact our sales department.
Locking options (See page 27)
Quarter turnlock
STANDARD
Key lock Touch catchBudget lock
CEILING/WALL PANELS
www.jakdor.co.uk • Tel: +44 (0)1922 71118512
CEILING/WALL PANELS
www.jakdor.co.uk • Tel: +44 (0)1922 71118512
WALL PANELS
DimensionsAll ceramic type access panels are custom made to order. This is to ensure that the access panel fits discretely into the tiled area avoiding unnecessary cutting of tiles.
Locking options
TILED ACCESS PANELJAK.CTDSpecificationManufactured to order from 1.5mm thick Zintec steel with a front perforated flange (hidden when tiled), and is polyester powder coated with a matt white RAL 9010 20% gloss. The recessed door is lined with 12.5mm moisture resistant plasterboard and comes complete with a sliding pin hinge system. Various locking systems are available including budget lock, touch catch, three-way locking, ball catch, security lock etc. For more information please contact our technical sales department.
FireThis is a non-fire rated access panel. For fire rated panels refer to typeJAK.CTD.FR60/120.
Section view
Tile faced wall access panel JAK.CTD wall panels are designed to fit into any type of wall system allowing easy access into the void, to be finished with ceramic or marble tiles. The doors are designed to be concealed and match the tile arrangement, the gap around the door matching the grout width. A quick release hinge allows removal of the door to give maximum access and eliminates contact between the edges of tiles when in use. For areas of high humidity please specify a stainless steel version.
Three -way locking
Quarter turn lock
Budget lockSTANDARD
Touchcatch
Ballcatch
CEILING/WALL PANELS
www.jakdor.co.uk • Tel: +44 (0)1922 711185 13
CEILING/WALL PANELS
www.jakdor.co.uk • Tel: +44 (0)1922 711185 13
CEILING/WALL PANELSWALL PANELS
FIRE RATED TILED PANELJAK.CTD/FR60SpecificationManufactured to order from 1.5mm thick Zintec steel with a front perforated flange (hidden when tiled), and is polyester powder coated with a matt white RAL 9010 20% gloss. The recessed door is lined with 12.5mm moisture resistant plasterboard and comes complete with a sliding pin hinge system. A three-way locking system is used to secure the panel, other locking inserts are available, see locking options. For more information please contact our technical sales department.
FireThe JAK.CTD/FR60/120 has been independently tested to BS476. Part 22, 1987.
Section view
DimensionsAll ceramic type access panels are custom made to order. This is to ensure that the access panel fits discretely into the tiled area avoiding unnecessary cutting of tiles.
Locking options
JAK.CTD/FR120SpecificationSimilar design to the JAK.CTD/FR60 access panel but 2 Hour Integrity Fire Rated. For more information please contact our technical sales department.
Three -way lockingSTANDARD
Quarter turn lock
Touchcatch
JAK.CTD/FR60 wall panels are designed to fit into any type of wall system to be finished with ceramic or marble tiles that requires a fire rating up to 1 hour. The doors are designed to be concealed and match the tile arrangement. The gap around the door matching the grout width. A quick release hinge allows removal of the door to give maximum access and eliminates contact between the edges of tiles when in use. For areas of high humidity please specify a stainless steel version.
Fire rated tile faced wall access panel
CEILING/WALL PANELS
www.jakdor.co.uk • Tel: +44 (0)1922 71118514
CEILING/WALL PANELS
www.jakdor.co.uk • Tel: +44 (0)1922 71118514
DimensionsVarious sizes can be manufactured up to approximately 600 x 600 depending upon the actual size of the tile to be fitted to the door tray on site. (For larger sizes refer to access panel type JAK.CTD).
Locking options
BUDGET TILED ACCESS PANELJAK.CTD/B1SpecificationThe frame and recessed door tray are manufactured from 1.0mm thick Zintec steel which is polyester powder coated to RAL 9010 20% gloss. The recessed door is a lift out type which is held in place at the top of the door with either two push and release type catches fixed to the inside edges of the frame, or alternatively a standard budget lock.
FireThis is a non-fire rated access panel. For fire rated panels refer to typeJAK.CTD.FR60/120
Section view Budget lockTouch catchSTANDARD
Budget Tile faced wall access panel
JAK.CTD/B1 budget range of ceramic wall access panels has been introduced to cater for situations where minimal access is required to gain entry to stop taps, plumbing joints etc, which are hidden behind a tiled wall/partition. The JAK.CTD/B1 consists of a metal frame with lift out door tray held in place with either touch catches, or standard lock.
WALL PANELS
S/Steel Collar & Plastic Dome PlugInserted Through Hole Cut Into Ceramic Tile On Site
Budget Lock
S/Steel Collar &Plastic Dome Plug
Tee Key
Lift Door Up& Away
Front Elevation Section Through PanelIn Locked Position
Section Through PanelIn Unlocked Position
WALL/CEILING PANELS
www.jakdor.co.uk • Tel: +44 (0)1922 711185 15www.jakdor.co.uk • Tel: +44 (0)1922 711185 15
DimensionsPlease ensure that on installation of the access panel, the actual size of structural opening in the ceiling/wall needs to be 5mm larger than the overall panel size e.g. Structural opening for 102 x 152 will be 107 x 157 (See sizes below).
PLASTIC ACCESS PANELJAK.PLASSpecificationManufactured from 3mm thick high impact styrene plastic with U.V. stabilizers, with white textured exposed surface to allow for painting. The panel has a 25mm picture frame for retrofit and rounded safety corners on the door. Simple to install and available in five sizes.
FireThis is a non-fire rated access panel.
Section view
Plastic access panel
JAK.PLAS plastic access panels are designed to fit into any type of ceiling/wall system where access is required to stopcocks, pipes etc. Or simply used to fill unsightly holes, saving the need for expensive repairs.The high impact styrene plastic with U.V. stabilizers will not fade or corrode.
OPEN DOOR WITH FLAT HEADED SCREWDRIVER
20
ADHESIVEBEDDING
HINGE
STRUCTURAL OPENING + 5mm LARGER THAN PANEL SIZE WALL / CEILING
25
CEILING/WALL PANELS
www.jakdor.co.uk • Tel: +44 (0)1922 71118516
CEILING/WALL PANELSCEILING PANELS
DimensionsPlease ensure that on installation of the access panel, the actual size of structural opening in the ceiling needs to be 5mm larger than the overall panel size e.g. Structural opening for 655 x 555 will be 660 x 560 (See sizes below). Non standard sizes are available on request, please contact our sales department.
Locking options (See page 27)
Loft hatch with picture frame
JAK.LOFT.PF Loft panels are designed to fit into any type of ceiling system in order to gain access to domestic loft areas. The rear of the metal door tray is fitted with 65mm thick, foil backed insulation board with a thermal conductivity value of 0.023 W/mK.A 25mm wide picture frame surround is provided for retrofit. The enables the panel to be inserted directly into the clear structural opening and screw-fixed into position through the side of the panel frame.
Budget lockSTANDARD
Pull catch
LOFT ACCESS PANELJAK.LOFT.PFSpecificationManufactured from 1.2mm thick Zintec Steel frame and 1.0mm thick Zintec Steel door tray with a polyester powder coating of matt white RAL 9010 20% gloss. The door has a concealed continuous hinge, and is secured using either a standard budget lock or pull latch (please state which option required).
FireThis is a non-fire rated access panel. Please see type JAK.LOFT.PF/FR60 for a 1Hour Fire Rated Panel.
Section view
25
STRUCTURAL OPENING +5mm LARGER THAN PANEL SIZE
METAL DOOR TRAYFILLED WITH INSULATION
PICTURE FRAMERING PULL LATCH CONTINUOUSHINGE
80
PANEL FRAME CEILING JOIST
CEILING/WALL PANELS
www.jakdor.co.uk • Tel: +44 (0)1922 711185 17
DimensionsPlease ensure that on installation of the access panel, the actual size of structural opening in the ceiling needs to be 5mm larger than the overall panel size e.g. Structural opening for 655 x 555 will be 660 x 560 (See sizes below). Non standard sizes are available on request, please contact our sales department.
Locking options (See page 27)
FIRE RATED LOFT PANELJAK.LOFT.PF/FR60SpecificationManufactured from 1.2mm thick Zintec Steel frame and 1.0mm thick Zintec Steel door tray with a polyester powder coating of matt white RAL 9010 20% gloss. The inside of the metal door tray is filled with mineral fibre insulation with a k value of 0.037 W/mK. The door has a concealed continuous hinge, and is secured using a three-way locking system.
FireThe JAK.LOFT.PF/FR60 has been successfully tested up to 1 hour fire integrity. Fire doors have smoke strips fitted on the frames. DO NOT interfere with these seals.
Section view
Fire rated loft hatch with picture frame
JAK.LOFT.PF/FR60 Loft panels are designed to fit into any type of 1 hour fire rated ceiling system in order to gain access to domestic loft areas. The rear of the metal door tray is filled with mineral fibre insulation with a k value of 0.037 W/mK. The door has a concealed continuous hinge, and is secured using a three-way locking system. A 25mm wide picture frame surround is provided for retrofit. The enables the panel to be inserted directly into the clear structural opening and screw-fixed into position through the side of the panel frame.
Pull catchThreeway-lockingSTANDARD
CEILING PANELS
25
STRUCTURAL OPENING +5mm LARGER THAN PANEL SIZE
METAL DOOR TRAYFILLED WITH INSULATION
PICTURE FRAME
CONTINUOUSHINGE
80
PANEL FRAME
CEILING JOIST
3 - WAY LOCKINGSYSTEM
CEILING/WALL PANELS
www.jakdor.co.uk • Tel: +44 (0)1922 71118518
CEILING/WALL PANELS
DimensionsPlease ensure that on installation of the access panel, the actual size of structural opening in the ceiling needs to be 5mm larger than the overall panel size e.g. Structural opening for 655 x 555 will be 660 x 560 (See sizes below). Non standard sizes are available on request, please contact our sales department.
Locking options (See page 27)
LOFT ACCESS PANELJAK.LOFT.BFSpecificationManufactured from 1.2mm thick Zintec Steel frame and 1.0mm thick Zintec Steel door tray with a polyester powder coating of matt white RAL 9010 20% gloss. The door has a concealed continuous hinge and is secured using either a standard budget lock or pull latch (please state which option required).
FireThis is a non-fire rated access panel. Please see type JAK.LOFT.BF/FR60 for a 1 Hour Fire Rated Panel.
Section view
Loft hatch with concealed beaded frame
JAK.LOFT.BF Loft panels are designed to fit into any type of ceiling system in order to gain access to domestic loft areas. The rear of the metal door tray is fitted with 65mm thick, foil backed insulation board with a thermal conductivity value of 0.023 W/mK.A 25mm concealed beaded frame surround is provided for taping and skimming on site. The enables the panel to be inserted directly into the clear structural opening and screw-fixed into position through the side of the panel frame.
Budget lockSTANDARD
Pull catch
CEILING PANELS
25
STRUCTURAL OPENING +5mm LARGER THAN PANEL SIZE
METAL DOOR TRAYFILLED WITH INSULATION
PERFORATED FRAMETAPED & SKIMMED ON SITE
RING PULL LATCH CONTINUOUSHINGE
80
PANEL FRAMECEILING JOIST
CEILING/WALL PANELS
www.jakdor.co.uk • Tel: +44 (0)1922 711185 19
CEILING PANELS
DimensionsPlease ensure that on installation of the access panel, the actual size of structural opening in the ceiling needs to be 5mm larger than the overall panel size e.g. Structural opening for 655 x 555 will be 660 x 560 (See sizes below). Non standard sizes are available on request, please contact our sales department.
Locking options (See page 27)
FIRE RATED LOFT PANELJAK.LOFT.BF/FR60SpecificationManufactured from 1.2mm thick Zintec Steel frame and 1.0mm thick Zintec Steel door tray with a polyester powder coating of matt white RAL 9010 20% gloss. The inside of the metal door tray is filled with mineral fibre insulation with a k value of 0.037 W/mK. The door has a concealed continuous hinge, and is secured using a three-way locking system.
FireThe JAK.LOFT.BF/FR60 has been successfully tested up to 1 hour fire integrity. Fire doors have smoke strips fitted on the frames. DO NOT interfere with these seals.
Section view
Fire rated loft hatch with concealed beaded frame
JAK.LOFT.BF/FR60 Loft panels are designed to fit into any type of ceiling system in order to gain access to domestic loft areas. The rear of the metal door tray is filled with mineral fibre insulation with a k value of 0.037 W/mK. The door has a concealed continuous hinge, and is secured using a three-way locking system.A 25mm concealed beaded frame surround is provided for taping and skimming on site. The enables the panel to be inserted directly into the clear structural opening and screw-fixed into position through the side of the panel frame.
Three -way lockingSTANDARD
Pull catch
25
STRUCTURAL OPENING +5mm LARGER THAN PANEL SIZE
PERFORATED FRAMETAPED & SKIMMED ON SITE
3 - WAY LOCKINGSYSTEM
CONTINUOUSHINGE
80
PANEL FRAME
CEILING JOIST
METAL DOOR TRAYFILLED WITH FIRE
PROOF INSULATION
CEILING/WALL PANELS
www.jakdor.co.uk • Tel: +44 (0)1922 71118520
CEILING/WALL PANELS
DimensionsPlease ensure that on installation of the access panel, the actual size of the structural opening in the ceiling needs to be 5mm larger than the overall panel size eg. Structural opening for 600mm diameter would need to be 605mm diameter (See sizes below). Non standard sizes are available.
Locking and unlockingTo unlock, exert upward pressure on the door face whilst turning anti-clockwise. Once the door has been disengaged from the frame pins then the door can be lowered. The safety chain will have to be removed to allow full removal of the door.
To lock is a reverse procedure of the above.
STANDARD PANELJAK.CIRC.PFSpecificationManufactured from 1mm thick Zintec Steel, with a polyester powder coating of matt white RAL 9010 20% gloss. The flush metal door has a three pin locking position and is supplied with a safety chain.
FireThis is a non-fire rated access panel.
Section view
Circular panel with metal door & picture frame
JAK.CIRC.PF Circular ceiling panels are designed to fit into any type of ceiling system allowing easy access into the void.A 25mm wide picture frame surround is provided for retrofit. This enables the panel to be inserted directly into the clear structural opening and screw-fixed into position through the side of the panel frame.
CEILING PANELS
SCREWFIXING
STRUCTURAL OPENING +5mm LARGER THAN PANEL SIZE
30
25METAL DOOR TRAY
LOCATION PINS
PICTUREFRAME
PANEL FRAME
CEILING/WALL PANELS
www.jakdor.co.uk • Tel: +44 (0)1922 711185 21
CEILING PANELS
DimensionsPlease ensure that on installation of the access panel, the actual size of the structural opening in the ceiling needs to be 5mm larger than the overall panel size eg. Structural opening for 600mm diameter would need to be 605mm diameter (See sizes below). Non standard sizes are available.
Locking and unlockingTo unlock, exert upward pressure on the door face whilst turning anti-clockwise. Once the door has been disengaged from the frame pins then the door can be lowered. The safety chain will have to be removed to allow full removal of the door.
To lock is a reverse procedure of the above.
STANDARD PANELJAK.CIRC.BFSpecificationManufactured from 1mm thick Zintec Steel, with a polyester powder coating of matt white RAL 9010 20% gloss. The flush metal door has a three pin locking position and is supplied with a safety chain.
FireThis is a non-fire rated access panel.
Section view
JAK.CIRC.BF Circular ceiling panels are designed to fit into any type of ceiling system allowing easy access into the void.A concealed beaded frame surround is provided for taping and skimming on site. This enables the panel to be inserted directly into the clear structural opening and screw-fixed into position through the side of the panel frame.
Circular panel with concealed beaded frame
SCREWFIXING
STRUCTURAL OPENING +5mm LARGER THAN PANEL SIZE
30
25 PERFORATED FRAME TAPED &
SKIMMED ON SITE
PANEL FRAME
METAL DOOR TRAY
LOCATION PINS
www.jakdor.co.uk • Tel: +44 (0)1922 71118522
CEILING PANELS
DimensionsWhen ordering please state the manufacturers tile size, type and thickness.Clear opening dependent upon tile size.Various types are available dependant on the type of grid and tile used;*JAK.EXP.24.SE for use within 24mm wide table tee system using square edged tiles*JAK.EXP.24.TEG for use within 24mm wide table tee system using tegular ceiling tiles*JAK.EXP.15.TEG for use within 15mm wide table tee system using tegular ceiling tiles
Locking options
STANDARD PANELJAK.EXPSpecificationManufactured from 1mm thick Zintec steel, the door tray and frame are polyester powder coated matt white, RAL9010, 20% gloss. The door tray is recessed to accept a trimmed ceiling tile. The access panel is designed to fit between the two “T” sections of the grid. Independent bracing is recommended.
FireThis is a non-fire rated access panel.
Section view
Exposed lay in grid
JAK.EXP Ceiling panels are designed to fit into a “lay in grid”/exposed grid type of suspended ceiling system allowing easy access into the void.
Key lockBudget lockSTANDARD
HANK BUSH & SCREWSECURING LOOSE COVERTO DOOR TRAY
REDUCED CEILING TILEINSERTED INTO DOORTRAY ON SITE
BUDGET LOCK KEY
CEILINGTILE
REMOVABLEPLASTIC PLUG
HINGE PIN SLOT IN FRAME
BUDGETLOCK
ACCESSPANEL FRAME
HINGE PIN BLOCKIN CHANNEL CEILING GRID
TEE SECTION
50
OPEN
CEILING/WALL PANELS
www.jakdor.co.uk • Tel: +44 (0)1922 711185 23
CEILING PANELS
DimensionsWhen ordering please state the manufacturers tile size, type and thickness.Clear opening dependent upon tile size.
Locking options
STANDARD PANELJAK.CONSpecificationThe JAK.CON is designed to sit onto the primary grid. Independent bracing is recommended.
FireThis is a non-fire rated access panel.
Section view
Budget lockSTANDARD
JAK.CON Ceiling panels are designed to fit into a newly constructed concealed grid type of suspended ceiling system allowing easy access into the void.The recessed door tray has a removable loose edge to enable a trimmed ceiling tile to be inserted into the door tray.
Concealed lay in grid
REMOVABLE PLASTIC PLUG
TRIMMED CEILING TILE INSERTEDINTO DOOR TRAY ON SITE
CEILINGTILE
HANK BUSH & SCREWSECURING LOOSE COVER
TO DOOR TRAY
SCREW FIXING
HINGE PIN BLOCK IN CHANNEL
HINGE PIN SLOTIN FRAME
DOOR TRAY
TILE RUNNERWELDED TO FRAME
ACCESS PANELFRAME
BUDGETLOCK
BUDGET LOCK KEY
75
OPEN
CEILING/WALL PANELS
www.jakdor.co.uk • Tel: +44 (0)1922 71118524
CEILING/WALL PANELS
CONTROLLED DESCENT ELECTRICALLY OPERATED
Accessories and Installation
It should be noted that the access panel will require independent bracing and support which is suffi cient to secure and also allow the safe opening of the access panel within the ceiling/wall system. For ceiling access panels greater than 600 x 600, it is advisable to request the fi tting of safety chains or friction hinges.
Dampers/friction hinges can be fi tted for controlled descent. Alternatively a safety chain can be incorporated to prevent ceiling door from dropping.
Internal handle for operation from above. A female Tee key operates the door from below.
Internal catch. Used to prevent the door from dropping.
The lid is held shut by a heavy duty 24v electromagnetic solenoid switch, which can be wired into the FAS or BMS system.
Operated by a 24v DC actuator. A 24v transformer can be supplied with controls. Contact our sales department for further details.
CEILING/WALL PANELS
www.jakdor.co.uk • Tel: +44 (0)1922 711185 25
CEILING/WALL PANELS
LOCKING OPTIONS
Budget Lock Three - Way Locking Touch Catch Heavy Duty Touch Catch Ball Catch
Tamper Proof LockKey LockSlotted Cam Lock Quarter Turn Lock Pull Catch
CEILING/WALL PANELS
www.jakdor.co.uk • Tel: +44 (0)1922 71118526
PLASTIC CEILING/WALL PANELS
FITTING INSTRUCTIONS
1. Mark wall using inner fl ange as a guide.
4. Place panel into the prepared aperture, make sure frame is level and press fi rmly until adhesive is set. Use suitable adhesive for permanently damp or wet areas.
5. Fit door to frame. 6. To open door prise open with a screw driver at the visible slot on one edge of the door.
2. Cut aperture on wall 5mm larger than the door size.
3. Apply thin layer of caulking adhesive to rear of frame.
CEILING/WALL PANELS
www.jakdor.co.uk • Tel: +44 (0)1922 711185 27
FITTING INSTRUCTIONS
5. Skim over the frame. 6. Work around the frame. If using panels with a PLASTERBOARD door, skimming over door should be done at the same time as frame.
1. Cut the plasterboard to the aperture,which needs to be 5mm larger than the panel size.
2. Place the panel into the aperture, ensuring frame is flush with surface.
7. Clean out the plaster from between door and frame before painting.
8. Apply the first coat of emulsion to the door and ceiling. Simple to operate; remove the plastic plug, insert the Tee key into the budget lock and rotate 45 degrees. Ensure there is sufficient clearance for the lock to operate correctly.
3. Fix the panel though the side of the frame only, using the pre-punched holes. Screw fix through fixing points. Additional packers may be needed to prevent distortion of the frame.
4. Apply scrim tape around the frame. Access panels with a concealed beaded frame are designed for a wet finish. Scrim tape must be applied to all beaded edges prior to plastering. (If using panels with a PLASTERBOARD door, apply scrim tape to door)
IMPORTANT NOTE: if scrim tape is not used the plaster may not adhere to the access panels frame.
CEILING/WALL PANELS
CEILING/WALL PANELS
www.jakdor.co.uk • Tel: +44 (0)1922 71118528
CEILING/WALL PANELS
www.jakdor.co.uk • Tel: +44 (0)1922 71118528
SRH ROOF HATCH
SRH Roof Hatch
SRH single or double leaf roof hatches are manufactured in aluminium with an optional polyester powder coated finish to any RAL colour. Each SRH is insulated against heat loss and condensation to maintain the thermal integrity of the building. Weighted sounds reductions can also be incorporated.
The gas spring assisted opening lid is supported by heavy duty aluminium hinges and features an integral ‘wrap over’ edge, incorporating double unbroken EPDM seals. The upstand has a purpose made flashing to accept the roof felt to make it weatherproof. The hatch also incorporates a safety hold open stay to prevent against accidental closure. Various locking options are available.
*Offering a U-value of 0.43W/m²K.*GWP (global warming potential) of 3.*ODP (o-zone depletion potential) of 0.
Standard stock sizes
* Non standard sizes available upon requestPULL HANDLE
SLAM CABLOCK 'HOLD OPEN'SAFETY STAY
STRUCTURAL OPENING
GAS SPRINGASSISTED OPENING
20030
0366
OPENING + 257mm
DOUBLE SEAL
6 DIA FIXINGHOLE IN FLANGE
LID INSULATIONU-VALUE 0.43W/m²KGWP - 3 ODP - 0
95FLANGE
ROOF MEMBRANE BY OTHERS
TH
ERMALLY BROKEN
EXTRUDED SECTION
CEILING/WALL PANELS
www.jakdor.co.uk • Tel: +44 (0)1922 711185 29
CEILING/WALL PANELS
www.jakdor.co.uk • Tel: +44 (0)1922 711185 29www.jakdor.co.uk • Tel: +44 (0)1922 711185
LOCKING OPTIONS
FEATURES
LO1 Standard CablockInternal opening only.
LO2 Standard Cablock with Internal Hasp & Staple for Increased Security
LO3 Standard Cablock & Tee KeyInternal and External opening.
LO4 Standard Cablock & Non-Locking External Handle
LO5 Standard Cablock & Locking External HandleInternal and external opening.
LO6 European DeadlockInternal thumb turn, external key opening with standard cablock and non-locking handle.
LO7 European DeadlockInternal and external key opening with standard cablock and non-locking handle.
CL - Curb LinerSurespan hatches can be fi tted with curb liners to ease site installation.
LH - Louvered HatchVentilated access hatch with louvered panels on four sides.
RS - Roof Hatch With Run-Off SkirtAll Surespan hatches can be provided with an encased upstand and run-off skirt.
SG / LE - Safety Grill/Ladder Extension Provided for safety and convenience, acting as a barrier or ladder extension when upright anda security grill when folded down.
RH - Retractable Hand HoldThe optional retractable hand hold improves the safety and convenience of ladder access.
HRS - Handrail SupportHandrails can be fi tted to assist entry and exit.
AP - Acoustic PerformanceSurespan hatches can be designed to offer excellent sound reduction of 45db Rw, measured in accordance with ISO 140-3: 1995 and rated in accordance with ISO 717-1: 1997.
FR - Fire RatedSurespan access covers can be rated for 3 hours fi re resistance for integrity to BS476: parts 21 and 22: 1987.
IP - Insulation PerformanceSurespan hatches are designed to offer a high level of thermal insulation against heat loss and condensation. U-Values of 0.78or 0.43W/m²K are available.
SRH ROOF HATCH
CEILING/WALL PANELS
www.jakdor.co.uk • Tel: +44 (0)1922 71118530 www.jakdor.co.uk • Tel: +44 (0)1922 71118530
ZIP RETRACTABLE LADDERS
Retractable Zip Ladders
The retractable ZIP ladder provides the simple solution to ceiling access. Incorporating deep and wide treads, a counterbalance spring ensures that the stairway can be opened with a minimum of effort.
Mounted on a head board for easy installation. Maximum loading 200kg/tread or 500kg/m² of the overall structure.
A complete roof access package can be provided consisting of; SRH roof hatch with an integral ZIP retractable ladder, factory fitted to a reinforced extended skirt liner and JAKDOR ceiling access door.
*Note: Add 50mm to allow for frame thickness of Jakdor ceiling door. Customer to ensure the aperture size is large enough for their requirements.
Height Closed -approx 500mm(Requires 100mm headroom)
Floor to ceiling height/
bottom edge of head board(add thickness of panel whenused with ceiling door)
Note: the ladder should be fitted as low as possible in the aperture to give maximum headroom.
80mm spacer requiredbehind head board(by others)
‘X’ Dimension
Optionaltelescopichandrail
Extended for Use
JAKDORDrop DownCeiling Door
Extended SkirtAdjustable Heightas required
Surespan SRH Roof Hatch
Wall Mounted Rungs
Closed for StorageSuspended Ceiling
Roof
TreadSize
CEILING/WALL PANELS
www.jakdor.co.uk • Tel: +44 (0)1922 711185 31
BIOCOTE
BioCote antimicrobial protectionEach day millions of people around the world trust BioCote to provideproven, evidence-based antimicrobial product protection.
Utilising the power of silver ion technology, BioCote antimicrobialprotection helps inhibit the growth of bacteria on the surface ofproducts, making them cleaner, safer and more hygienic to use.
®
®
®
Jakdor with BioCote Jakdor access panels are available for a broad spectrum of environments where good hygiene practices are essential such as; healthcare establishments, schools andkitchens. With increased media and Government focus on reducing levels of bacteria such as MRSA E-coli and Salmonella, BioCote can be added to all Jakdor products offering a hygienic solution and limiting the spread of bacteria and the risk of cross-contamination.
Key benefits;• BioCote helps reduce the risk of cross-contamination• BioCote is completely safe• BioCote does not deteriorate with age• There is no evidence that bacteria can become resistant to BioCote
®
®
®
®
®
®
Surespan LimitedLeamore Close | Leamore Enterprise Park | Walsall | West Midlands | WS2 7NLTel: +44 (0)1922 711185 | Fax : +44 (0)1922 714099 | E-mail: sales@jakdor.co.uk Copyright © Surespan 2010
FM23434BS EN ISO 9001 : 2000
In the interest of continued improvement Surespan reserve the right to modify any product or specification wothout prior notice.
Surespan Ltd. hold a number of British and International patents. It is company policy to defend our intellectual property rights.
Your local distributor is:
Recommended