Our corporate philosophy is to maximize value by customer-friendlydesign. For this purpose, we are including every customer needsfor various applications in our product design in order to provide ourcustomers best detectors, best service. It is the reason that we canmanufacture the world best detectors as well as world best quality.
Best Detectors,Best Service
C-910C, Bupyeong Woolim Lions Valley, #425 Cheongcheon-Dong, Bupyeong-Gu, Incheon, KoreaTel. +82-32-623-7507 / Fax. +82-32-623-7510
Web. www.gasdna.com Email. sales@gasdna.com
8/13/2019 Catalog English 2012
2/23
8/13/2019 Catalog English 2012
3/23
Installation-Type Infrared Thermometer
IR-40_ 04 IR-21_ 04 IR-20_ 05 IR-80_ 05 6-IRman_ 06 10-IRman_ 06
IR-80-H_ 07 Ascon Infrared Thermometer_ 07 Infrared Thermometer-Accessories_07
Portable Infrared Thermometer
PIR550_08 PIR1500_08 PIR2400_08
Installation-Type Gas Detector
DI-20 Series_09
DA-91 Series_09
SMART Gas detector
DA-500_ 10 DA-100_ 10 DA-800_ 11 DA-750_ 11 DA-50_ 12
Radio Environment Air Quality Monitor
IAQ-700_ 12
NH3,CH4,CO2-Raser Gas Monitor_ LGD F200_ 13
Smoke Senser
SD-110_ 13 SD-50_ 14
Single-type Gas Detector Receiving Unit
GMS-1000_ 14
4-Channel Gas Detector Receiving Unit
GMS-1500_ 15
Multiple-type Gas Detector Receiving Unit
GMS-2000_ 15
CONTENTS
8/13/2019 Catalog English 2012
4/23
04
Installation-Type Infrared Thermometer
Segment IR-40
Range 0~1,000
Resolution 0.1Emissivity 0.1~0.99
Response Time Within 0.5 sec.
Accuracy 2 or 1%
Field of View (D:S) 40:1
Wavelength Range 8~14
Input Power 12V~24V
External Material Aluminum
Cable Length 3M
Segment IR-21
Range 0~400
Resolution 0.1
Emissivity 0.95(Fixed)
Response Time Within 0.5 sec.
Accuracy 2 or1%
Field of View (D:S) 12:1
Wavelength Range 8~14
Input Power 12V~24V
External Material Aluminum
Cable Length 3M
Model Description
Code A Temperature range
1 0~1000
2 0~700
3 -20~1000
Z Other
Code B Output
M DC 0~20mA
N DC 4-20mA
V Voltage output DC 1~5V
Z Other
CODE C Cable length
1 3M
Z Other
Model Description
Code A Temperature range
1 0~400
2 0~700
3 -20~700
Z Other
Code B Output
M DC 0~20mA
N DC 4-20mA
V Voltage output DC 1~5V
Z Other
CODE C Cable length
1 3M
Z Other
22
59
DISTANCE: SENSOR TO OBJECT (IN)
D:S=40:1
SPOTDIA.*
(MM)
SPOTDIA.*
(IN)
DISTANCE: SENSOR TO OBJECT (MM)
*FOCUS POINT D:S = 40:1 FAR FIELD D:S = 40:1
0.9
15001000500
28
44
1.1
1.7
4020
18
1000
83
8
3.3
20 40
DISTANCE: SENSOR TO OBJECT (IN)
D:S=12:1
SPOTDIA.*
(MM)
SPOTDIA.*
(IN)
DISTANCE: SENSOR TO OBJECT (MM)
*FOCUS POINT D:S = 12:1 FAR FIELD D:S = 12:1
0.3
500250100
21
42
0.8
1.7
104
Product Specification
Product Specification
Optical Field of View
Optical Field of View
Dimension
Dimension
Code Number IR-40---
Code Number IR-21---
IR-40
IR-21
Non-contact infrared thermometer
Non-contact infrared thermometer
8/13/2019 Catalog English 2012
5/23
05
Installation-Type Infrared Thermometer
Segment IR-20
Range 0~400
Resolution 0.1Emissivity 0.95(Fixed)
Response Time Within 0.5 sec.
Accuracy 2 or1%
Field of View (D:S) 10:1
Wavelength Range 8~14
Input Power 12V~24V
External Material Aluminum
Cable Length 3M
Segment IR-80
Range 500~1700
Resolution 0.1
Emissivity 0.1~0.99
Response Time Within 0.1 sec.
Accuracy 2 or1%
Field of View (D:S) 80:1
Wavelength Range 0.9~1.5
Input Power 12V~24V
External Material Aluminum
Cable Length 3M
Model Description
Code A Temperature range
1 0~400
2 0~200
Z Other
Code B Output
N DC 4-20mA
V Voltage output DC 1~5V
Z Other
CODE C Cable length
1 3M
Z Other
Model Description
Code A Temperature range
1 500~1500
2 500~1700
3 250~650
Z Other
Code B Output
M DC 0~20mA
N DC 4-20mA
V Voltage output DC 1~5V
Z Other
CODE C Cable length
1 3M
Z Other
1000
100
10
4.0
20 40
DISTANCE: SENSOR TO OBJECT (IN)
D:S=10:1
SPOTDIA.*
(MM)
SPOTDIA.*
(IN)
DISTANCE: SENSOR TO OBJECT (MM)
*FOCUS POINT D:S = 10:1 FAR FIELD D:S = 10:1
0.4
500250100
25
50
1.0
2.0
104
2000
25
6
1.0
59 79
DISTANCE: SENSOR TO OBJECT (IN)
D:S=80:1
SPOTDIA.*
(MM)
SPOTDIA.*
(IN)
DISTANCE: SENSOR TO OBJECT (MM)
*FOCUS POINT D:S = 80:1 FAR FIELD D:S = 80:1
0.2
15001000500
13
19
0.5
0.7
4020
Product Specification
Product Specification
Optical Field of View
Optical Field of View
Dimension
Dimension
Code Number IR-20---
Code Number IR-80---
IR-20
IR-80
Non-contact infrared thermometer
Non-contact infrared thermometer
8/13/2019 Catalog English 2012
6/23
06
Segment 6-IRman
Range -20~600
Resolution 0.1Emissivity 0.1~0.99
Response Time Within 0.5 sec.
Accuracy 2 or1%
Field of View (D:S) 10:1
Wavelength Range 8~14
Input Power 12V~24V
Cable Length 3M
Segment 10-IRman
Range -20~1000
Resolution 0.1
Emissivity 0.1~0.99
Response Time Within 0.5 sec.
Accuracy 2 or1%
Field of View (D:S) 40:1
Wavelength Range 8~14
Input Power 12V~24V
External Material Aluminum
Cable Length 3M
Model Description
Code A Temperature range
1 -20~600
2 -20~400
3 0~100
Z Other
Code B output
M DC 0~20mA
N DC 4-20mA
Z Other
CODE C Cable length
1 3M
Z Other
Model Description
Code A Temperature range
1 -20~1000
2 0~500
3 0~100
Z Other
Code B output
M DC 0~20mA
N DC 4-20mA
Z Other
CODE C Cable length
1 3M
Z Other
1000
100
10
4.0
20 40
DISTANCE: SENSOR TO OBJECT (IN)
D:S=10:1
SPOTDIA.*
(MM)
SPOTDIA.*
(IN)
DISTANCE: SENSOR TO OBJECT (MM)
*FOCUS POINT D:S = 10:1 FAR FIELD D:S = 10:1
0.4
500250100
25
50
1.0
2.0
104
22
59
DISTANCE: SENSOR TO OBJECT (IN)
D:S=40:1
SPOTDIA.*
(MM)
SPOTDIA.*
(IN)
DISTANCE: SENSOR TO OBJECT (MM)
*FOCUS POINT D:S = 40:1 FAR FIELD D:S = 40:1
0.9
15001000500
28
44
1.1
1.7
4020
18
Product Specification
Product Specification
Optical Field of View
Optical Field of View
Dimension
Dimension
Code Number 6-IRman---
Code Number 10-IRman---
6-IRman
10-IRman
Non-contact infrared thermometer
Non-contact infrared thermometer
Installation-Type Infrared Thermometer
8/13/2019 Catalog English 2012
7/23
07
Segment IR-80-H
Range 500~1700
Resolution 0.1Emissivity 0.1~0.99
Response Time Within 0.2 sec.
Accuracy 2 or1%
Field of View (D:S) 80:1
Wavelength Range 1~1.7
Input Power 12V~24V
External Material Aluminum
Cable Length 3M
Range 0~400
Wavelenght Range 8~14
Accuracy 2 or 2% of measured value
Input Power 12V~24V
Model Description
Code A Temperature range
1 350~650
2 500~1700
Z Other
Code B output
M DC 0~20mA
N DC 4-20mA
V Voltage output DC 1~5V
Z Other
CODE C Cable length
1 3M
Z Other
Product Specification
Product Specification
Optical Field of View Dimension
Code Number IR-80-H---
IR-80-H
Ascon Infrared Thermometer
Infrared Thermometer Accessorces
Non-contact infrared thermometer
Installation-Type Infrared Thermometer
Airpurge Water-cooling jacket Bracket RS485 to RS232 Converter
Real-time in the Computer Real-time data storage oftemperature
2000
25
6
1.0
59 79
DISTANCE: SENSOR TO OBJECT (IN)
D:S=80:1
SPOTDIA.*
(MM)
SPOTDIA.*
(IN)
DISTANCE: SENSOR TO OBJECT (MM)
*FOCUS POINT D:S = 80:1 FAR FIELD D:S = 80:1
0.2
15001000500
13
19
0.5
0.7
4020
8/13/2019 Catalog English 2012
8/23
08
Segment PIR550
Range -60~550
Wavelength Range 8~14
Operating Temperature 0~50
Accuracy 2 or 2% of measured value
Emissivity 0.1~1.0
Response Time within 1 Sec.
Field of View (D:S) 12:1
Battery life min 14 hours continuous use
Dimensions 143.9*116.73*42.78mm
Weight 180g(including battery)
Segment PIR1500
Range -35~1500
Wavelength Range 8~14
Operating Temperature 0~50
Accuracy 2 or 2% of measured value
Emissivity 0.1~1.0
Response Time within 1 Sec.
Field of View (D:S) 75:1
MemoryDetailed 24 Memories withTemperature & Emissivity
Dimensions 143.9*116.73*42.78mm
Battery lifemin 14 hours continuous use
(without Laser and Back Light)
Dimensions 204.14*179.19*58.40mm
Weight 355g(including battery)
Segment PIR2400
Range 200~2400
Wavelength Range 1~2
Operating Temperature 0~50
Accuracy 2 or 2% of measured value
Emissivity 0.1~1.0
Response Time within 1 Sec.
Field of View (D:S) 100:1
MemoryDetailed 24 Memories withTemperature & Emissivity
Dimensions 143.9*116.73*42.78mm
Battery lifemin 14 hours continuous use
(without Laser and Back Light)
Dimensions 233.8*207,5*60.6mm
Weight 550g(including battery)
Product Specification
Product Specification
Product Specification
PIR550
PIR1500
PIR2400
Portable Infrared Thermometer
Portable Infrared Thermometer
Portable Infrared Thermometer
Portable Infrared Thermometer
8/13/2019 Catalog English 2012
9/23
09
Product Specification
Product Specification
DI-20 Series
DA-91 Series
Multi Input Indicator-compact type
Audiovisual displayGas Detecter
Installation-Type Gas Detecter
Segment DI-20
Input Type
(User-Selectable Multiple Input)
TC (B, R, S, K, E, J, T, N), RTD (DIN PT1, DIN PT(0.1), JIS PT)
DC (mV, V, mA)Accuracy 0.2% / Output Signal: 0.25% (Full scale)
Dimensions and Display Cycle 100 ms (mV, Volt, mA type), 200 ms (TC, TRD type)
Input Resistance Volt type is 400 , mA type is 250 , 1 is for other types
Signal Source Resistance PT100 , 30 /Line, Other types 300 / Line
NMRR / CMRR More than 50 dB / More than 140 dB
Alarm (Option)Channels : 2 or 4 alarms, Contact point : 1a (Normal, Open)Contact capacity : AC 250 V / 5 A, DC 30 V / 5 A
Communication Specification(Option)
Kind : RS232, RS422, RS485, ID (Address) setup : 1 ~ 127Signaling speed : 4800 bps ~ 57600 bps
Output Signal (Option) Electrical insulation Current : DC4 ~ 20 mA / 600
Use EnvironmentStorage Temperature/Humidity : -20 ~70 / 5%~95%Operating Temperature/Humidity : -5 ~60 / 10%~90%
Power Consumption 3.5 W (Max.)
Input Power AC 85 V ~ 264 V
Insulation resistance FG input, FG power, power input, More than 100 (500 VDC)
Built-in Sensor Power DC 24 V / 30 mA / less than 0.5 %
Weight About 450 g
Size (mm) 96 (W) x 48 (H) x 100 (D) mm
Installation Method Panel-mounting type
Segment DA-91
Detection target gas oxygen, nitrogen and toxic gas
Detection principle Electro-Chemical, or NDIR
Response time within 10 Sec, 90%/Full Scale
Accuracy 3%/Full Scale
Input power AC 220V/60Hz
External output 4~20mA, 2stage(AL1/AL2) Alarm RELAY CONTACT, RS-485(Option)
Alarm display
Low Alarm - AL1 LED(RED)
High Alarm - AL2 LED(RED)
Sight-mars light display - BZ LED(RED)
Alarm typemars light off
hearing - buzzer(90/1m)
Operating Tompereture /Humidity
-20~50, 5~95% RH (Non-Condensing)
Alarm off Manual, Automatic return
Installation Method Wall Mounting Type
Measuring range 0 ~ 10,000 ppmDimension
8/13/2019 Catalog English 2012
10/23
10
Segment DA-500
Detection PrincipleCatalytic combustion, Non-dispersive infrared
(NDIR), TCD, Electro-chemical
Detection Method Diffusion type
Target Gas Combustible gas, Toxic gas
Detection Range 0 ~ 100% LEL, 0 ~ 10,000 PPM, 0 ~ 100% VOL
Response Time Within 30 sec. 90% / Full scale
Accuracy 3% / Full scale
Display Back light LCD (2 Lines 8 Characters)
Checking Function Sensor fault indication on LCD (SEN -err), 2 Output
Select ion Function Calibration concentration, Detection range setting
Input Power DC 20 V ~ 30 V
External Output 4 mA ~ 20 mA / Full scale - 2.5 Km Transmission
OperatingTemperature/Humidity
-20 ~ 60 , 5 ~ 95% RH (Non-condensing)
Signal Cable CVVS & CVVSB 1.25 sq x 3Wire shielded type
Cable Conduit 1/2 or 3/4 PF, NPT
Installation Method Wall or Pipe station
External Material Cast aluminum alloy
Explosion-ProofApproval
Ex d IIC T5 KGS
Relay contacts Two step- Relay Contact (High/Low)
Segment DA-100
Detection Principle Catalytic combustion, TCD, Electro-chemical
Detection Method Diffusion type
Target Gas Combustible gas, Toxic gas
Detection Range 0 ~ 100% LEL, 0 ~ 10,000 PPM, 0 ~ 100% VOL
Response Time Within 10 sec, 90% / Full scale
Accuracy 3% / Full scale
Checking Function Sensor fault indication on FND (S.Er), 2 Output
Input Power DC 20 V ~ 30 V
External Output 4 mA ~ 20 mA / Full scale - 2.5 Km Transmission
OperatingTemperature/
Humidity-20 ~ 60 , 5% ~ 95% RH (Non-condensing)
Signal Cable CVVS & CVVSB 1.25 sq x 3 Wire-shield type
Cable Conduit 1/2 or 3/4 PF, NPT
Installation Method Wall or Pipe station
External Material Cast aluminum alloy
Explosion-ProofApproval
Ex d IIC T5 -KGS
H2
0 %LEL
w
g
R
ww.
A
00.01
-
S
a.c4v
2r
o
D -DA SN m
-1 MOEDLAD
O
ap
TE
2-H/G
ET
CD
M
nesdw
o
E
G
01
T
XD
I
I
C
5
X0E
Product Specification
Product Specification
Dimension
Dimension
DA-500
DA-100
SMART Gas detector
SMART Gas detector-Indicator type DA-500. Series
SMART Gas detector - Non-indicator typeDA-100. Series
8/13/2019 Catalog English 2012
11/23
11
Segment DA-800
Detection Principle Catalytic combustion, TCD, NDIR, Electro-chemical
Detection Method Suction type
Target Gas Combustible gas, Toxic gas
Detection Range 0 ~ 100% LEL, 0 ~ 100% VOL, 0 ~ 10,000 PPM
Response Time Within 10 sec, 90% / Full scale
Accuracy 3% / Full scale
Induced Vacuum Flow 1.5 l/min ~ 2.5 l/min
Selection Function Calibration concentration, Detection-range setting
Input Power DC 20 V ~ 30 V
External Output 4 mA ~ 20 mA / Full scale - 2.5 Km Transmission
Operating Temperature/Humidity
-20 ~ 60 , 5% ~ 95% RH (Non-condensing)
Signal Cable CVVS & CVVSB 1.25 sq x 3 Wire shielded type
Cable Conduit 1/2 or 3/4 PF, NPT
Suction Line ConduitPipe
1/4 Tube
Installation Method Wall mounting
External Material Cast aluminum alloy
Explosion-ProofApproval
Ex d IIB+H2 T6- Korea Testing Laboratory (KTL)
Output Options 2 Step Relay-Contact (High/Low), RS-485
Segment DA-750
Detection PrincipleCatalytic, Electro-chemical, Non-dispersive infrared
(NDIR), Photo-ionization (PID)
Detection Method Suction type
Input Power 20 V ~ 30 V (24 V DC Normal) / 250 mA (Max.)
Induced Vacuum Flow 100 cc ~ 2.0 l/min
Accuracy 3% Full scale
External Output 4 mA ~ 20 mA DC, RS-485
Gas Leak Data Storage Gas leak records: 4,000
DisplayGraphic LCD (128 dots*64 dots) Korean/English
PPM, % LEL, %VOL(Adjustable by user programming)
Operating Display 4 LEDs (Power, 2 Alarms, 1 Trouble)
Alarm Value Setting AL1, AL2 2 Stage(Adjustable by user programming by user)
Alarm Delay Time 0 sec ~ 99 sec(Adjustable by user programming by user)
Relay Outputs 125 V 0.6A / 3 SPST Relay-Contact(2 Alarm, 1 Trouble)
Operating Temperature/Humidity -20 ~ 60, 5% ~ 95% RH (Non-condensing)
Installation Method Wall mounting
Signal Cable CVVS & CVVSB 1.25 sq x 3 wire shielded type
Gas Flow Distance Less than 100 m
Gas Inlet Tube 6 Tube
NH3 PPM
10.0 F
L
O
W
P OW ER F AU LT A L1 A L2
UP
RESET MODE
D OW N E NT
TEST
U P D OW M
MOTOR
Product Specification
Product Specification
Dimension
Dimension
DA-800
DA-750
SMART Gas detector
SMART Gas detector-Suction typeDA-800. Series
SMART Gas detector-Suction typeDA-750. Series
8/13/2019 Catalog English 2012
12/23
12
Segment DA-50
Detection PrincipleCatalytic, Electrochemical, Non-dispersive infrared
(NDIR), Photo-ionization (PID)
Detection Method Diffusion type
Input Power 20 V ~ 30 V (24 V DC Normal) / 100 mA (Max.)
Accuracy 3% Full scale
External Output 4 mA ~ 20 mA, 2 Step Relay (AL1, AL2) RS-485
Display LCD(8Characters*2Line) With Back-light %,PPM,PPb
Operating Display 4 LEDs (Power, 2 Alarms, 2 RS485 TX, RX)
Relay Outputs 125 V 0.6 A / 2-SPST Relay-Contact (2 Alarms)
Target Gas Toxic gas (Refer to detection target toxic gas list)
Installation Method Wall mounting
Signal Cable Cvvs &Cvvsb 1.25 sq *3Wire shielded type
OperatingTemperature / Humidity
-20 ~ 60 , 5% ~ 95% RH (Non-condensing)RESET MO DE U P D OW N ENT
POW AL 1 A L2 R X TX
GAS DETECTOR
M/G
OUT
DC 24V
4-20mA
MODEL: DA-50
GASDNA CO.,LTD
POW
NH
OPPM
3
Product Specification
Product Specification
Dimension
DA-50
SMART Gas detector
Radio Environment Air Quality Monitor
SMART Gas detectorDA-50. Series
IAQ-700This equipment measures indoor air quality and is displayed by the number,Especially CO2, Temperature, Humidity, VOC, Dust etc,) and can be easilyinstalled indoor.
Rating CO2
Input PowerDimensions
DC 9V~24V310*157*60
Detection MethodDetection RangeResponse TimeOperating Temperature/Humidity
Temperature Humidity
RangeResolutionRepeatabilityResponse Time
-25 ~ +600.1E0.1(Min)5 ~ (Max)30sec
RangeResolutionRepeatabilityResponse TimeNonlinearity Raw data
0~100%RH1%RHE0.1%RH1/e(63%)slowly moving airE3%RH Nonlinearity
8/13/2019 Catalog English 2012
13/23
13
Segment SD - 110
General Form 1 or, 2 Channel Monitoring
Product Type Wall-mounting type
Detection Principle Ionizations Smoke Chamber
Detection Method Diffusion type
Response Time Within 3 min.
Detection Range 0 ~ 500 Pcs/L
External Output 4 ~ 20
Input Power DC 24V
Alarm Type High / Low 2 Step Alarm (user-setup)
Alarm off-type Manual or Automatic (user-selection)
Signal Cable CVVS & CVVSB 1.25sq x 3 Wire - Shield Type
Operating Current 500. Maximum
System InitializationTime
Within 50 min
External Structure Monitoring Unit - Metal, Sensor Unit - Aluminum
Operating Temperature/Humidity
-20~ 50 / 0 ~ 95% RH (Non-Condensing)
Process-Type Digital Process
SD - 110
Smoke Detector
Gas D&A CO.
Product Specification
Dimension
NH3,CH4,CO2-Laser GAs Monitor
Smoke Sensor SD-110
LGD F200
System specifications
Dimensionscell layout
Integrated flow-throughcell
Cell temperature Ambient(A)/Heated(H) Up to 190
Dimensions range ppm or %
Typical dynamicrange
2000Range extension possibleupon request
Electrical Feature
Power supply 10~30V DC
Power Consumption of detector 2W
Optional cel l heater powerconsumption(H)
Up to 100W For heating up to 190
Data out Digital:Rs232 Analog:4-20mA or0-5V
8/13/2019 Catalog English 2012
14/23
14
Segment SD - 50
Detection Principle Ionization smoke chamber
Detection Method Diffusion type
Response Time Within 3 sec.
External Output A contact (DC 30 V 1 A), B contact
Input Power DC 22 V ~ 26 V
Operating Current 25 (max.)
External Material Acetal
Operating Temperature/Humidity
-20 ~ 65 / 0 ~ 95% RH (Non-condensing)
Product Specification
Dimension
Dimension
Smoke Sensor
Single-type Gas detector Receiving unit GMS-1000
SD-50
Segment GMS - 1000
Structure Single type / 1 Circuit
Input Power AC 230 V / 60 Hz
Input Signal 4 ~ 20 DC / Full scale
Output Power DC 24 V (250 )
Output Signal 4 ~ 20 DC / Full scale
Signal Resolution A/D Converter 20000, D/A Converter 12 Bit
Display % LEL (Combustible), % (Oxygen), PPM (Toxic)
Alarm DisplayLow alarm AL1 LED (Red)High alarm AL2 LED (Red)
Fault alarm Fault LED (Yellow)
Alarm TypeVisual : LED flickering
Auditory : Buzzer sound (More than 80 )
Alarm DensityAL1 / AL2 2 Level alarm density
(Adjustable by user programming by user)
Alarm Delay Time0 sec ~ 99 sec
(Adjustable by user programming by user)
Alarm Off Manual , Automatic return
Alarm Output 2 Level (AL1 / AL2) Relay-Contact
OperatingTemperature
-20 ~ 70
Operating Humidity 5 % ~ 95 % RH (Non-condensing)
External Material Poly Carbonate (PC)
Installation Method Wall mounting
Product Specification
8/13/2019 Catalog English 2012
15/23
15
SegmentGMS - 2000
Power & Alarm Unit Receiving Unit
Control Structure Alarm unit : Receiving unit = 1:1 - 64 Receiving unit : detector = 1:1
Extension Structure Slide Card Type
Input Power AC 230V / 60Hz
Output Power DC 24V(250)
Input Signal 4 ~ 20 DC/F.S
Output Signal 4 ~ 20 DC/F.S , RS-485(Option)
Display % LEL (Combustible), % (Oxygen), PPM (Toxic)
Power Display Power LED (Green)
Alarm DisplayAlarm LED (Red)
Alarm LED flickering
Low alarm AL1 LED (Red)High alarm AL2 LED (Red)
Fault alarm - Fault LED (Yellow)
Alarm Type Buzzer sound (More than 80 )Visual : Applicable alarm LED
Flickering
Alarm DensityHigh / Low - 2Level alarm density(Adjustable by user programming
by user)
Alarm Delay Time0 sec ~ 99 sec (Adjustable by
user programming by user)
Alarm Off Manual, Automatic return
Alarm Output SPST Relay output for High / Low 2Level alarmSPST Relay output for Fault alarm
OperatingTemperature /
Humidity-20 ~ 60, 5 ~ 95%RH (Non-Condensing)
External Material 19 (3U) Unit : Al uminum / System enclosure : Metal case
Output Options RS-485
GAS ALARM CONTROL SYSTEM
()
Product Specification
Product Specification
Dimension
Dimension
4-Channel Gas detector Receiving unit
Multiple type Gas detector Receiving unit GMS-2000
GMS-1500
Segment GMS - 1500
Structure Multiple-type (4 Connection detectors) / 4 Circuits
Input Power AC 220 V / 60 Hz, AC 110 V / 60 Hz (Option)Input Signal 4 Channels (4 ~ 20 / FS)
Output Power DC 24 V (250 )
Output Signal 4 Channels (4 ~ 20 / FS)
DisplayLCD Display PPM, % LEL, %, PPB
(Adjustable by user programming by user)
Alarm DisplayLow alarm AL1 LED (Red)High alarm AL2 LED (Red)
Fault alarm Fault LED (Yellow)
Alarm TypeVisual : LED Flickering
Auditory : Buzzer sound (More than 80 )
Alarm Value SettingAL1/AL2 2 Level alarm
(Adjustable by user programming by user)
Alarm Delay Time
0 sec ~ 99 sec
(Adjustable by user programming by user)
Alarm Off Manual, Automatic return
Alarm Output 250 V 5 A / 11-SPST Relay-Contact (10 Alarms, 1 Fault)
OperatingTemperature
-20 ~ 70
Operating Humidity 5 % ~ 95 % RH (Non-condensing)
External Material Poly Carbonate (PC)
Installation Method Wall mounting
8/13/2019 Catalog English 2012
16/23
SYSTEMCONFIGURATION
DC 4-20mA
RS-485
RS-232/RS-485
DA-800
DA-50 SD-50 CD-10 CD-30
GMS-1000
DA-750 GMS-1500
DA-500 GMS-2000
DA-100 PLC
CONVERTER
8/13/2019 Catalog English 2012
17/23
SYSTEMCONFIGURATION
Displaying real-timetemperature, on/off relay,& alarm
GO/NO GO signal
Signal to measure temperature
RS-485
IR-80 Non-contact infrared thermometer
DA-90 Site displaying unit Data collection and monitoring unit
TCP/IP communication(real-time temperature data transfer)
Robot
Coil spring
Main process control system
Producing quality controlchart Recording and reportingdata, trend of temperature,& alarm which can beconverted into excel format
Alarming low & hightemperature
8/13/2019 Catalog English 2012
18/23
Customers
Steel
Glass
Tire
Plastic
Other
Automotive
Paper
Semiconductor
Cement
Power station
Food
8/13/2019 Catalog English 2012
19/23
Metal Processing
1205
Result inIncreased productivityReduced energy costHigher qualityReduced downtimeEasy data recordingEnhanced worker safety
Continuous CasterIR-80 Non-contactinfrared thermometerfor targets in steamy/dusty environment
Hot Rolling millIR-80 Non-contact infraredthermometer for targets obscuredby airborne contaminants
Cold MillIR-40 Non-contact infraredthermometer for spotdimensions
Rod/Wire MillIR-80 Non-contact infraredthermometer for dusty and steamyenvironments, for fast moving targets,for targets smaller than field of view
Reheater Interior-Ambient Temperature compensation-Real-time temperature trending
Reheat FurnaceIR-80 Non-contact infraredthermometer for targets in steamy/dusty environment
IR-80 Non-contact infraredthermometer IR-80 Non-contact infrared
thermometer
PC monitoring and data collection unit
IR-80 Non-contactinfrared thermometer(enclosed in coolingJacket)
IR-80 Non-contact infraredthermometer (mounted inCooling Jacket) checkingbillet exit temperature
RoughingStands
PinchRolls
FinishingStands
Water Box(controlled cooling)
IR-80 Non-contactinfrared thermometer
IR-80 Non-contactinfrared thermometer
IR-80 Non-contactinfraredthermometer
Blast Gate
Senser
ScaleBreaker
RoughingStands
Shear FinishingStands
Cooling DownCoiler
Senser
Senser
Senser
Direction
Uncoiler RecoilerFinishing Stands
Senser
SenserSenser
Senser Senser
Closed-end CeramicSighting Tube
Reheat Furnace Interior
Thermocouple
8/13/2019 Catalog English 2012
20/23
Glass Processing
Crwon
Feed Hopper
Regenerator(Cross-fired)
Sensor inside ThermoJacketmeasures molten glass in canalfor proper furnace exit temperature IR-80 Non-contact infrared
thermometer
FromfurnaceFromfurnace Forehearth
Gob
Automated glass containerForming machine
Annealing Lehr Cold end surfacetreatment area
To sorting, packaging,and shipping
IR-80 or IR-40 Non-contactinfrared thermometerIR-80 Non-
contact infraredthermometer
Canal
Tomanufacturing
Portable sensors measureexterior for hot spot detection(deteriorating refractory material)
Melt Furnace
Flat glass
Glass fiber Automotive windshield
Bottles and containers
Sensors mounted insideThermoHackets measure packingmaterial temperature for optimumregenerator airflow control
IR-80 Non-contact infrared thermometermonitor exit temperatures
Air-cooled fixed sensors mounted over Tin Bath and Lehr makesure zone temperatures are correct
Molten glassfrom furnace
To cutters and stackers
Tin Bath1. Heater zone
2. Fire polish zone3. Cooling zone
Portable sensors help maintain tanksand mechanical parts
IR-80 or IR-40 Non-contactinfrared thermometer
IR-80 or IR-40 Non-contactinfrared thermometer
IR-80 or IR-40 Non-contactinfrared thermometer
Flat Glassfrom Stock
Heating Section
Forming Section
To Cooling Section
IR-80 Non-contact infraredthermometer monitor heater exit tocheck flat glass temperatures beforeentering forming section.
IR-80 Non-contactinfrared thermometerconnector to computerscan automatically adjustthe cooling process.
Fromfurnace
To cuttingand packaging
CuringovenConveyor belt
Forehearth
Spinners
Annealing LehrControlled cooling in 4 to 8 separate zones
8/13/2019 Catalog English 2012
21/23
8/13/2019 Catalog English 2012
22/23
Paper
Automotive
Busbar temperature monitoring
Process automation system
OVEN DRYER
DIE
COOLING
8/13/2019 Catalog English 2012