View
219
Download
0
Category
Preview:
Citation preview
7/29/2019 Catalog ACDC Surge Protectors - Red Series (http://shop.acdc-dcac.eu/)
1/10
Nine (9) Stages Surge Protector
TelecommunicationMobile Base Station
Medical Equipment
Industrial
Residental
Military
Computers
Single & Three Phase Modular
Installation - Hard Wire
Broadcast
Sensitive Electronic
Hard Wire Installation
Cascade bi-directional EMI-RFI filtering
of phase (L), neutral (N) and
IEC61643-1 Class I+II+III; IEC60939-2
ground (GND) wire
Surge Protection
MULTI-STAGE
CLASS I+II+III
SurgeProtection
NEW INNOVATION APPROACH TO SURGE PROTECTION
Catalog ACDC Surge Protectors - Red Series
Innovated Multi-Stage Surge Protection
GREEN POWER SUPPLY
7/29/2019 Catalog ACDC Surge Protectors - Red Series (http://shop.acdc-dcac.eu/)
2/10
. . . We Care for Safety of Your Electronic Devices
This catalogue is the part of the Main Catalogue of ACDC DCAC CompanyCatalog ACDC Surge Protectors - Multi Stage Surge Protection
We reserve the right to introduce changes in performance,dimensions and material in the course of technical progress.
7/29/2019 Catalog ACDC Surge Protectors - Red Series (http://shop.acdc-dcac.eu/)
3/10
Surur eMULTI-STAGE SURGE PROTECTION
www.acdc-dcac.euEmpowered by Innovation
Sur e ProtectionG
CLASSCLASSI+II+IIII+II+III 200
homeome telecomelecom industryndustrycenterenterITTIPIP
3300 11 22LPZLPZ
ACDC SURGE PROTECTOR
NINE (9) STAGES 1/1 & 3/3SERIES PROTECTOR
ACDC ProtectorSurge Type - PI (780; 7100; 7125; 7200) Red Seriesis d -stage oradvance multi surge protect consists of 9 nine 100s that s
. The protection device have high grade cascade bi-directional of phase (L) and neutral (N) wire with option forground (GND) filtering. It also has special diagnostic for ground condition.
ACDC protectors have
high-grade bidirectional filtering. They are tracking AC waveform eliminatingso-called pollution in power AC supply.
These protectors have special design to protect and improve functioning ofsophisticate equipment in Telecommunications, Broadcast, Medicalequipment, Computers, Military, Solar Photovoltaic and Residental.
Surge9 nine
(22kW)
Installation of Surge type - PI is excellentchoice for investment in the quality of your power network supply, extendedequipment life and reduce their down time and errors.
( ) & Aprotection stage provide effective and reliable protection againstsurges and transients
EMI/RFI filtering
The scope of applications of ACDC Surge Protectors is quitewide and refers to the protection of electrical devices against impulse surgeand high-frequency (electromagnetic) disturbance, oscillation, speaks innetwork power supply and atmospheric discharge.
The basic module of type ACDC Protector -Red Series is ( ) stages Single Phase Protector with modularconfiguration for single or three phase applications for load currents of up to100A per phase.
ACDC Protector
If the stages 2,4 and 6 are out of function, the stages 1,3,7 and8 are still provide a high grade cascade bi-directional filtering along withultimate (5-th) protection stage.
Application:
Investment:
Technical Specifications:
Reliability:
electrical devices for application.and industrial
igh current capability, up to 100A, makes these
protectors ideal equally for low power sensitive
ACDC Protector Type- PISurge Series
H
ith simple words, design and planning of surge
protection is not any more reserved just for experts
in this field. It become simple and applicable to wide
branch of professions: electrician, const. builders, IT..
Implementation
.
of ACDC Surge Protectors is simple and
easy
EC 62305-4 & ANSI/IEEE C62.41.1-2)
Regarding multi-stage design of Class I+II+III in
one unit with ACDC Surge Protectors is
acc.
I
expel need of
several surge protectors installed separately in each
boundary protection zone (LPZ0a/LPZ0b-LPZ3 & C-A
EASIER SIMPLER BETTER
is specifically designed to protect, upgrade and improve
functioning of computer , telecommunication, medical,
audio, video and all sensitive electronic equipment.
s
HARD WIRE INSTALLATION- MODULAR SYSTEM
Single Phase / Three Phase CLASS I+II+III
Voltage 120VAC /230VAC /400
Current Rating: up to 100A per phase
Rating: VAC
Response Time: < 1ns
Type-PI (780; 7100; 7125; 7200) Red Series
7/29/2019 Catalog ACDC Surge Protectors - Red Series (http://shop.acdc-dcac.eu/)
4/10
Technical Specification
Type - PI Red Series
NINE PROTECTION STAGES:
50
70
36
45
82
SIDE VIEW
72
18
TOP VIEW
Surur e MULTI-STAGE SURGE PROTECTION
acdc-dcac@acdc-dcac.eu New materials, New design, New approach to Surge Protection Industry
Cascade bi-direct ional EMI-RFI fi lteri ng of phase (L) neutral (N) and (Gnd) wir e
ACDC Protector
Type-PI
Surge
Red Series
Basic Circuit Diagram per Phase - Red Series:
TVS
LimiterBi-directionalFilter
(No back EMF effect)
C C
C
C
ThermalCut-Off
ThermalCut-Off
ControlGTD
ControlGTD
GTD
Var. Var.
Red Yellow Green
LOUT
without filtering GND IN
LIN for parallel application
LIN for series application
GND IN for ground filtering for ground filtering GND OUT
Bi-direct.Filter
NOUTNIN
Philosophy:
Approach:
Technology:
Design:
Installation:
The ACDC Surge Protectors have coordinated approach tolightning protection, surge and transient protection as well as grounding,an approach that embraces all aspects of potential damage. No singletechnology can effective protect electronic devices from the damagingeffects of lightning and induced transients, which can severely damage ordestroy electronic systems.
In order to provide the optimum level of protection, ACDC has developedintegrate 9 (nine) stages Surge protector that provides effective and reliableprotection against surges and transients.
ACDC Surge ProtectorsSurge p Bi-directional f
ACDC Surge Protectors
multi-stage -.
ACDC Surge Protector Type-PI Red Series is protector of classI+II+III in one according to IEC61643. They also full fill standardrequirements for electromagnetic (radio) interference IEC60939-2.
surge protection .
The ACDC Surge Protector - Red Series could be install inseries or parallel configuration depending of total load (>100A
7/29/2019 Catalog ACDC Surge Protectors - Red Series (http://shop.acdc-dcac.eu/)
5/10
Technical Specification
Type - PI Red Series
Surge Cur. 150kA (8/20s)or 22kA (10/350s)
Surge Cur. 225kA (8/20s)or 32kA (10/350s)
Surge Cur. 125kA (8/20s)or 18kA (10/350s)
Surge Cur. 105kA (8/20s)or 15kA (10/350s)
Type PI 780 - RS Type PI 7100 - RS Type PI 7125 - RS Type PI 7200 - RSType
Order Code
Total Surge Current
Product Standard
800.135 800.136 800.137 800.138
IEC61643-1 Class I+II+III (B+C+D); IEC60939-2
First Protection Stage
Second Protection Stage
Third Protection Stage
Fifth Protection Stage
Sixth Protection Stage
Seventh Protection Stage
Eight Protection Stage
Function
Technology
Technical Specification
Technical Specification
Function
Technology
Technical Specification
Function
Technology
Technical Specification
Function
Technology
Technical Specification
Function
Technology
Technical Specification
Function
Technology
Technical Specification
Technical Specification
Bi-directional fil ring ; ;te EMI/RFI (L-N) Front signal edge reduction
Nano Cr stalline Core (L-C configuration)y
Surge Cur. 125kA (8/20s)or 20kA (10/350s)
Surge Cur. 200kA (8/20s)or 30kA (10/350s)
Surge Cur. 100kA (8/20s)or 15kA (10/350s)
Surge Cur. 80kA (8/20s)or 12,5kA (10/350s)
Bi-directional fil ring ; ;te EMI/RFI (L-N) Front signal edge reduction
Nano Cr stalline Core (L-C configuration)y
Suppression signal shape (L-N) 8/20 s,
Varistor with thermal cut-off
Long term signal suppression from 1 s to sec2 .
Controlled Gas Tube Discharge
High speed efficiency signal suppression
Transient Voltage Suppressor
Nano Cr stalline Core (L-C configuration)y
Function Suppression signal shape (L-N) 8/20 s or 10/350 s,
Technology Varistor with thermal cut-off Control Gas Tube Discharge;
Function
Technology
1. Stage
L=0.7mH; Imax=up to 100A
L=0.7mH; Imax=up to 100A
Surge Cur. kA (8/20 s)25
Fourth Protection Stage
This stage is the last ltimate protection level. switch-off the circuits breaker install if the pick voltage> 300DC (120 VAC) 5 0VDC (230 VDC output ircuits breaker
u He upstream,for or 2 for ) appears on the . C should be < 250A gl/gG.
TVS Limiter 500A (8/20 s) < 1ns (nanosecond); Typical response ec
L=0,7mH; Imax=up to 100A
2. Stage
3. Stage
4. Stage
5. Stage
6. Stage
7. Stage
8. Stage
Ninth Protection Stage
Technical SpecificationSurge Cur. 125kA (8/20s)
or 20kA (10/350s)Surge Cur. 200kA (8/20s)
or 30kA (10/350s)Surge Cur. 100kA (8/20s)
or 15kA (10/350s)Surge Cur. 80kA (8/20s)
or 12,5kA (10/350s)
Function Suppression signal shape (N ) 8/20 s or 10/350 s-Gnd ,
Technology Controlled Gas Tube Discharge
9. Stage
Ground filtering
Nano Cr stalline Core (L-C configuration)y
L=0,7mH
Bi-directional fil ring N L ; ;te EMI/RFI ( - ) Front signal edge reduction
Surur eMULTI-STAGE SURGE PROTECTION
www.acdc-dcac.euIntegrated Multi-Stage Protection
www.acdc-dcac.eu
Technical Specification per Phase ACDC Surge Protector - Red Series
7/29/2019 Catalog ACDC Surge Protectors - Red Series (http://shop.acdc-dcac.eu/)
6/10
Surur e MULTI-STAGE SURGE PROTECTION
acdc-dcac@acdc-dcac.eu ACDC DCAC Dan e Krapc ev n o.2/1 , 1000-Sko pj e, Macedo ni a Phon e: 3 89 2 3216 988; Fax : 389 2 3216 993
Models of Surge Protectors
Type - PI Red Series
Technology:
Load:
Specification: Cascade bi-directional EMI-RFI filtering of phase (L), neutral (N) and ground (GND) wire
Multi-Stage Surge Protection; Nine (9) Stages Series Protector
Order CodeType
450kA (8/20s) or66kA (10/350s)
675kA (8/20s) or96kA (10/350s)
375kA (8/20s) or54kA (10/350s)
315kA(8/20s) or45kA(10/350s)
Total Surge Cur.
Three Phase
Type-PI 780 3/3-MCB-RS
Type-PI 7100 3/3-MCB-RS
800.135-3/3-MCB
Type - PI 7125 3/3-MCB-RS
Type - PI 7200 3/3-MCB-RS
800.136-3/3-MCB
800.137-3/3-MCB
800.138-3/3-MCB
Dimension(WxDxHmm)
300x250x150
Weight(kg)
7,1
300x250x150
300x250x150
300x250x150
7,1
7,1
7,1
Order CodeType
450kA (8/20s) or
66kA (10/350s)675kA (8/20s) or96kA (10/350s)
375kA (8/20s) or54kA (10/350s)
315kA(8/20s) or45kA(10/350s)
Total Surge Cur.
Three Phase
Type-PI 780 3/3-M-RS
Type-PI 7100 3/3-M-RS
800.135-3/3-M
Type - PI 7125 3/3-M-RS
Type - PI 7200 3/3-M-RS
800.136-3/3-M
800.137-3/3-M
800.138-3/3-M
Dimension(WxDxHmm)
250x250x150
Weight(kg)
5,1
250x250x150
250x250x150
250x250x150
5,1
5,1
5,1
Order CodeType
450kA (8/20s) or66kA (10/350s)
675kA (8/20s) or96kA (10/350s)
375kA (8/20s) or54kA (10/350s)
315kA(8/20s) or45kA(10/350s)
Total Surge Cur.
Type-PI 780 1/1-RS x 3
Type-PI 7100 1/1-RS x 3
800.135-1/1 x 3
Type - PI 7125 1/1-RS x 3
Type - PI 7200 1/1-RS x 3
800.136-1/1 x 3
800.137-1/1 x 3
800.138-1/1 x 3
Dimension(WxDxHmm)
82x216x70
Weight(kg)
1,41
82x216x70
82x216x70
82x216x70
1,41
1,41
1,41
Order CodeType
150kA (8/20s) or22kA (10/350s)
225kA (8/20s) or32kA (10/350s)
125kA (8/20s) or18kA (10/350s)
105kA(8/20s) or15kA(10/350s)
Total Surge Cur.
Single Phase
Type-PI 780 1/1-RS
Type-PI 7100 1/1-RS
800.135-1/1
Type - PI 7125 1/1-RS
Type - PI 7200 1/1-RS
800.136-1/1
800.137-1/1
800.138-1/1
Dimension(WxDxHmm)
Weight(kg)
0,47
82x72x70
82x72x70
82x72x70
0,47
0,47
0,47
For upgrade the distribution panel
82x72x70
Three PhaseFor upgrade the distribution panel
Three single phase surge protectors connected for three phase application
The Surge Protectors are installed in Metal Distribution board with degree of protection IP54
The Surge Protectors are installed in Metal Distribution board with degree of protection IP54
Circuit breakers MCB 100A are installed in the front of protectors for each phase
Installation: Hard wire installation - Modular System
IEC61643-1 Class I+II+III; IEC60939-2Product Standard:
Options: Ground filtering, indication for bed grounding, remote alarm
Guideline for ordering of ACDC Surge Protectors of Red Series
www.acdc-dcac.eu
Single and Three phase Models - ACDC Surge Protectors - Red Series
* R phase, neutral and groundout ground for WG or
The Surge Protectors from series Type-PI 3/3-MBC- S are delivered with filtering as model basic option. By customer requestthe model could be delivered for installation with filtering or parallel installation with additional mark F P
Up to 100A per phase; 12kW per phase for 120VAC; 22kW per phase for 230VAC
7/29/2019 Catalog ACDC Surge Protectors - Red Series (http://shop.acdc-dcac.eu/)
7/10
Surur eMULTI-STAGE SURGE PROTECTION
Integrated Multi-Stage Protection www.acdc-dcac.eu
Operation Diagnostic
Application
Frequency attenuation:
Applications: Features:
Multi - Protection
Protection Stages
Bi-directional Filtering
Ground Filtering
Thermal Circuit ProtectionHigh Reliability
Response Time < 1ns
Stage Surge
Nine (9)
Excellent
- 80dB- 40dB- 10dB
10 100 1k 10k 100k
-20
-40
-60
-80
0.1 10k 100k 700k 1M
0
1k
Led Indication for correct stage no. 2,4 and 6. The
.
stages no. 1,3,7 and 8 (highgarde bi-directional filtering) are always in function along with ultimate (5-th)protection stage
Led Indication for correct stage no. 4,6 and un correct no 2. The
.
stages no. 1,3,7and 8 (bi-directional filtering) are always in function along with ultimate (5-th)protection stage
Only stages 1,3,7 and 8 are still in function along with ultimate (5-th) protectionstage.
Led Indication for bed grounding (Low impedance equipotential ground is notprovided)
Normal:
Fault:
Fault:
Fault:
Operation Diagnostic System
Red Yellow Green
Continuous yellow
and green
Continuous green
Blinking red
Continuous red
Application:
t (ms)
Random Noice
Voltage Spike
Waveform Tracking Filter
Safe Power Supply
5 10 15 20
U(V)
Uef
Home
Telekom
Industry Solar Wind energy
Mobile Base Station
Power Supply
Certificate of Quality
Varistors Standard
E
Pro Standard acc.
lect. Magn. Interfer.
tec.
ISO 9001:200
UL 1449
IEC 60
IEC 61643-1 lass I
8
IEC 61643-1;
939-2
C +II +III
Telecommunication
Computers
Medical equipment
Military
Solars
Sensitive electronic
Industrial grade
7/29/2019 Catalog ACDC Surge Protectors - Red Series (http://shop.acdc-dcac.eu/)
8/10
Installation Instruction
Type - PI Red Series Surur e MULTI-STAGE SURGE PROTECTION
ACDC DCAC Dan e Kr apcev no .2/1, 1000-Skop je , Mac edo ni a Phon e: 389 2 3216 988; Fax : 389 2 3216 993acdc-dcac@acdc-dcac.eu
ND IV,VIII
G
1, 3, 7 and 8 Stage: Filter (bi-directionalwave tracking);, 3, 7 and 8 Stage: Filter (bi-directional wave tracking);3dB-3kHz,38dB-100kHz,50dB-300kHz; 50bB-500kHzdB-3kHz,38dB-100kHz,50dB-300kHz; 50bB-500kHz2, 4 and5 Stage: Surge Limiter (L-N), 4 and 5 Stage: Surge Limiter (L-N)150kA (8x2050kA (8x20 s); 22kA (10/350); 22kA (10/350 s))6.Stage: MOSFETLimiter-500A (8x20. Stage: MOSFET Limiter-500A (8x20 s)(RT
7/29/2019 Catalog ACDC Surge Protectors - Red Series (http://shop.acdc-dcac.eu/)
9/10
. . . ACDC DCAC for Your Safety
7/29/2019 Catalog ACDC Surge Protectors - Red Series (http://shop.acdc-dcac.eu/)
10/10
Wave 8x20s
Wave 10x350sI
t (s)
I (kA)
max
Iimp
20
40
60
80
100
10 100 200 300 400 500 600 700 800 900 1000
s
u
r
e
g
Products Manufacture by
ACDC DCAC
Multi-Stage Surge Protection
Dane Krapcev no.2/1
1000 Skopje, Macedonia
Phone: 389 2 3216 988
Fax: 389 2 3216 993
acdc-dcac@acdc-dcac.eu
www.acdc-dcac.eu
ACDC Surge Protector
SurgeProtection
Eight (8) Stages Surge Protector
Three (3) Stages Surge Protector
Three Stages Signalization
IEC61643-21
Single Phase
Three Phase
Signal Line
Hard Wire
Plug In
Series Connection
Degree of
Protection
Standards
Application
Signalization
Connection
BlueSeries
GreenSeries
PinkSeries
RedSeries
OrangeSeries
U(V)
Uef
+ Umax2
- Umax2
+Uc
-Uc
+ Umax/2
t (ms)
Random Noice
Voltage Spike
Destructive Voltage
50Hz Sinusoidal
Waveform Tracking Filter
Safe Power Supply
5 10 15 20
Destructive Voltage
*IEC61643-1 Class I+II+III;IEC60939-2
*
Installation
Signal. for Ground Condition
Option for ground Filtering
No Ground Contamination
Grounding
Modularity
Degree of Enclosures IP54, IP65
Free Contact AlarmOptions
Parallel Connection (Optional)
AC Signalization
Signal Line Signalization
YellowSeries
Recommended