View
4
Download
0
Category
Preview:
Citation preview
C
DMDM
DM
DM DM
DM DM
DMDM
DMDM
DM
DM
DM
DM
DM
DM
DM
DM
C
D
BIO
TRASH
C
HOYER LIFT
SCALE
BIO
TRASH
D
BIO
TRASH
O2
CONC.
O2
CONC.
D
BIO
TRASH
D
C
D
C
C
C
C
C
C
CWP
Area For Water Supply
LABWORK
MEDPREP
NURSESTATION
PAT.PREP.
P
S
P
S
P
S
P
S
P
S
P
S
P
S
D
S
D
S
D
S
D
S
D
S
D
S
D
S
D
S
FAP
F
F
F
F
F
P
S
RTU-4
RTU-3
RTU-2
RTU-1
P
S
P
S
P
S
P
S
P
S
P
S
P
S
P
S
P
S
P
S
P
S
P
S
P
S
FA
CP
M
2
S1
S2
S3
S4
S5
S6
S7
S8
S9
S10
S11
S12
S13
S15
S16
S17
S18
S20
S21
S22
S23
S25
S27
S28
S29
S30
S34
S35
S36
S37
S38
S39
75cd
75cd
110cd
75cd
75cd
75cd
75cd
75cd
75cd
75cd
75cd75cd
75cd
75cd
75cd
75cd
75cd75cd
75cd
75cd
75cd
110cd
110cd
N1.1
N1.2
N1.3
N1.4
N1.5
N1.6N1.7
N1.8
N1.9
N2.1
N2.2
N2.3
N2.4
N2.5
N2.6
N3.1
N3.2
N3.3
N3.4N3.5
N3.6
N3.7
FACP NAC #3 EOL
FACP NAC #2 EOL
FACP NAC #1 EOL
N1.10
M1
M2
M3
M4
M5
M6
M7
R
R
R
R
R
R
R
R
M8
M9
M10
M11
M12
M13
M14
M15
75cd
N3.8
PROVIDED BY OTHERS
WF
VS
FACP
SS
P
S
S1
S2 M10 S3M11
S4
S5S6 M8M9
S7
M12S8
M13
S9
S10
M14
S11
M15
S12S13
M1
S15S16
S17 S18M2
S20S21
S22
S23M3
S25 M4S27
S28S29
S30M5
M6
M7
S34
S35S36 S37
S38
S39
D
S R
D
S R
P
S D
S R
D
S R
D
S R
D
S R
P
S D
S R
D
S R
P
S
P
S
F
P
S
P
S
P
S
P
S
F
P
S
P
S
P
S
F
P
S
F
P
S
F
P
S
F
M
2
WF
VS
P
S
P
S
P
S
P
S
P
S
P
S
N1.1
HOTNEUTRAL
120 VAC IN
DEDICATED BREAKER LABELED IN RED AT DISCONNECT,
WITH BREAKER LOCK.
N1.2 N1.3 N1.4 N1.5 N1.6 N1.7 N1.8
N2.1 N2.2 N2.3 N2.4 N2.5 N2.6
N3.1 N3.2 N3.3 N3.4 N3.5 N3.6 N3.7 N3.8
75cd 75cd 75cd 75cd 75cd 75cd
N1.9 N1.10
75cd 75cd 75cd75cd
75cd 75cd 75cd 110cd 75cd
75cd 75cd 75cd 75cd 110cd 110cd 75cd75cd
EOLR
EOLR
EOLR
FROM TELCO/
PRIMARY AND SECONDARY LINES
DESCRIPTION MANF.UNIT MODEL NO. QTY. BOXMOUNTING
EQUIPMENT SCHEDULE
CONTROL PANELS
Addressable Fire
Alarm Control Panel
S3
Gamewell
FCI
Surface Mount,
Provided with Unit
FACP1
F
Addressable
Photoelectric
Smoke Detector
ASD-PL2F
Gamewell
FCI
21
Octagon Box,
Minimum 3 Feet from
Air Diffuser
Addressable
Pull Station,
Dual Action
MS-7AF
Gamewell
FCI
5
4 Square Box
with Single Gang
Mud Ring @ 48" A.F.F
SLC LOOP DEVICES
P
S
Gamewell
FCI
Dual Monitor Module
(faceplate/ LED)
AOM-2IF
4" Square Deep Box
With Extension Ring
1
M
2
NOTIFICATION DEVICES
Horn Strobe,
Wall Mount
Standard cd, White
P2W
System
Sensor
12
Strobe,
Wall Mount
Standard cd, White
SW
System
Sensor
12
4 Square Box
@ 80" A.F.F
4 Square Box
@ 80" A.F.F
PROVIDED BY OTHERS
NA
Sprinkler System
Tamper Switch
NA
NA
Sprinkler System
Water Flow Switch
NA
NA NA
NA NA
FAP
LCD Touchscreen
Annunciator
LCD-SLP
Gamewell
FCI
1
Surface Mount,
Provided with Unit
NA
ACCESSORIES
Octagon Box,
Minimum 3 Feet from
Air Diffuser
Addressable
Heat Detector
ATPL2F
Gamewell
FCI
3
Motor
Bell
D
S
Duct Smoke
Detector Housing
DNR
Gamewell
FCI
8
Refer to
Manufacturer's
Installation Instructions
Duct Housing
Provided
R
Addressable
Relay Module
AOM-2RF
Gamewell
FCI
8
4 Square Box
with Extension Ring
Addressable
Smoke Detector
for Duct Detector
ASD-PL2FR
Gamewell
FCI
8
Octagon Box,
Minimum 3 Feet from
Air Diffuser
NANA
NA NA
NA
NA
NA
S
120VAC Surge
Protector
NA Edco 1
NA
NA
S
Phone line
Surge Protector
NA Ditek 1
NA
NA
WF
VS
PROVIDE MINIMUM 4 FEET SEPARATION BETWEEN SUPPLY AND RETURN LOOPS ON ALL STYLE 6 AND 7 CIRCUITS.
SIGNALING
LINE CIRCUIT #1
(6,200 FEET MAX.)
16 AWG
2 CONDUCTOR
SOLID FPLP
NOTIFICATION
APPLIANCE
CIRCUIT #1
14 AWG
2 CONDUCTOR
SOLID FPLP
DESCRIPTION TYPE LINE TYPE STYLE
6
Y
CIRCUIT LEGEND
NOTIFICATION
APPLIANCE
CIRCUIT #2
14 AWG
2 CONDUCTOR
SOLID FPLP
Y
NOTIFICATION
APPLIANCE
CIRCUIT #3
14 AWG
2 CONDUCTOR
SOLID FPLP
Y
RS-485 BUS
16 AWG
2 CONDUCTOR
SOLID FPLP
NA
ANNUNCIATOR
CIRCUIT
16 AWG
2 CONDUCTOR
SOLID FPLP
NA
LANNCO, INC.
ENGINEERING CONSULTING
CERTIFICATE OF AUTHORIZATION
# 26222
P.O. BOX 41481
ST. PETERSBURG,
FLORIDA 33743
(727) 345-8556
PROFESSIONAL SEAL
FRANK BONGHI
FLORIDA P.E. 54702
Sheet Number
FA-01
Sheet Name
FIRE ALARM PLAN
Scale
Date
Project
No.
Revision/Issue
Date
1.
-00/00
--
-
--
-
--
-
DAVITA TRINITY
08/12/16
Fort Knox &
Communications, Inc.
Fire
4517 George Road
Suite # 240
Tampa, Florida 33634
Tel (813) 653-1605
Fax (813) 653-1710
Lic# EF20000876
16'8'0'4'8'FIRE ALARM DEVICE LAYOUT
SCALE: 1/8 " = 1' - 0 "
1FA01
DEVICE VOLTAGE DROP CALCULATION
STANDBY BATTERY CALCULATION
RISER DIAGRAM
DA
VIT
A T
RIN
IT
Y
10
22
1 S
TA
TE
R
OA
D 5
4
NE
W P
OR
T R
IC
HE
Y, F
LO
RID
A 3
46
55
Recommended