Bumper Trajectories During High-Speed

Impacts with 6-in. Curbs

Ronald K. Faller, Ph.D., P.E.

Midwest Roadside Safety Facility (MwRSF)University of Nebraska-Lincoln

TRB Committee AFB 20June 15-18, 2008Jackson, Wyoming

Midwest Roadside Safety FacilityMidwest Roadside Safety Facility

Introduction

• MGS placed 6 in. (mid-face) behind 6-in. high, AASHTO Type B curb met TL-3 of NCHRP 350

• Pooled Fund States sponsored study to determine performance limits of MGS behind 6-in. curbs allow for some variability in MGS placement allow for sidewalk placement in front of MGS reduce snow plow impacts with rail & resulting damage determine lateral offset when MGS needs to be raised

• Obtain bumper trajectories for curb impacts with pickup trucks and small cars

• Evaluate critical MGS offsets using MASH 082

Midwest Roadside Safety FacilityMidwest Roadside Safety Facility

MGS w/ 6-In. Curb (Test NPG-5)

3

Midwest Roadside Safety FacilityMidwest Roadside Safety Facility

Bumper Trajectory Test Set-up

4

Midwest Roadside Safety FacilityMidwest Roadside Safety Facility

Vehicle-Curb Test - MGSC-1 (2270P)

5

4,966 lbs62.2 mph25 deg

Midwest Roadside Safety FacilityMidwest Roadside Safety Facility

Vehicle-Curb Test - MGSC-2 (2270P)

6

4,966 lbs62.6 mph25 deg

Midwest Roadside Safety FacilityMidwest Roadside Safety Facility

Vehicle-Curb Test - MGSC-3 (1100C)

7

2,544 lbs61.6 mph25 deg

Midwest Roadside Safety FacilityMidwest Roadside Safety Facility

Wheel Damage - MGSC-3 (1100C)

8

Midwest Roadside Safety FacilityMidwest Roadside Safety Facility

Vehicle-Curb Test - MGSC-4 (2000P)

9

4,479 lbs62.5 mph25 deg

Midwest Roadside Safety FacilityMidwest Roadside Safety Facility

Curb-Lateral Coordinate System

10

Vehicle

Curb

Curb-Lateral Direction

Longitudinal Vehicle Path

Midwest Roadside Safety FacilityMidwest Roadside Safety Facility

Critical Override Impact Point

11

Critical Point

Critical Point

Midwest Roadside Safety FacilityMidwest Roadside Safety Facility

12

Midwest Roadside Safety FacilityMidwest Roadside Safety Facility

13

Midwest Roadside Safety FacilityMidwest Roadside Safety Facility

Predicted Safe Zones – 31” MGS

14

Bars Represent Safe Zones

2000P (MGSC-4)

1100C (MGSC-3)

2270P (MGSC-2)

2270P (MGSC-1)

Processed Curb-Lateral Distance (ft)

50 10 15 20 25

Unclear

Midwest Roadside Safety FacilityMidwest Roadside Safety Facility

Predicted Safe Zones – 37” MGS

15

0

2270P (MGSC-1)

2270P (MGSC-2)

1100C (MGSC-3)

2000P (MGSC-4)

Bars Represent Safe Zones

Processed Curb-Lateral Distance (ft)

252015105

UnclearUnclear

Recommended