Beyond Compliance 1
General for BWM and BWTS
Beyond Compliance 2
General for BWM and BWTS
Morocco, Indonesia and Finland recently ratified at 29th IMO Assembly Ratification Status for BWM Convention(24th November 2015, www.imo.org)
Effectuation Criterion - Ratification by 30 States - 35% of world merchant shipping tonnage
47 States Ratification
35% over?
International Convention for the Control and Management of Ship’s Ballast Water and Sediments, 2004 adopted by BWM Conference(BWM/CONF/36) 16th Feb. 2004
Albania, Antigua & Barbuda, Barbados, Brazil, Canada, Congo, Cook Islands, Croatia, Denmark, Egypt, France, Georgia, Germany, Iran, Japan, Jordan, Kenya, Kiribati, Lebanon, Liberia, Malaysia, Maldives, Marshall Islands, Mexico, Mongolia, Montenegro, Netherlands, Nigeria, Niue, Norway, Palau, Republic of Korea, Russian Federation, Saint Kitts and Nevis, Sierra Leone, South Africa, Spain, Sweden, Switzerland, Syrian Arab Republic, Tonga, Trinidad & Tobago, Turkey, Turkmenistan Morocco, Indonesia and Finland
Beyond Compliance 3
General for BWM and BWTS
USCG BWM requirement has entered into force after 1 Dec. 2013
Implementation schedules for ballast water management system
Should be Type-approved by USCG to sail within US Port, however allowed for no longer than 5 years on condition of approval AMS by USCG (CG-OES Policy Letter No.13-01, 25 Sep. 2013)
Recently, 5 years limitation on a vessel’s max. duration of an extension was removed. (CG-OES Policy Letter No.13-01, Rev.1, 10 Sep. 2015)
This mean that continuous operation of an AMS installed onboard may be accepted. Extension requests must be written in English and submitted electrically as an e-mail (environmental_standard@uscg.mil), with an application spreadsheet(refer to www.krs.co.kr) with required information.
Beyond Compliance 4
Status of development for BWTS by treatment method(BWM.2/Circ.34/Rev.4(2015.5))
33 32
5
15
4 4 7
0
5
10
15
20
25
30
35
40
45
50
Electrolysis Ultra Violet Ozone Chemical Deoxydation Ozone+
(Electrolysis
or UV)
others
2
(%)
General for BWM and BWTS
Beyond Compliance 5
48
32
12 8
Ultra Violet Type
Electrolysis Type
Chemical Injection Type
Ozone Type
General for BWM and BWTS
Beyond Compliance 6
43
29
14
14 Cost of BWTS
Quality(Reliability) of BWTS
Operational Efficiency(Power Consumption) of BWTS
Period and Foot print of Installation
Survey on high priority choice of BWTS for ship’s owners in Korea(%)
Survey on preference of BWTS type for ship’s owners in Korea(%)
Case Study for Retrofitting BWTS on DWT 47K Oil/Chemical Tanker
Beyond Compliance 7
Main data for subject vessel
Beyond Compliance 8
Case Study for Retrofitting BWTS on DWT 47K Oil/Chemical Tanker
Ballast
tanks Total ballast
volume(m3) Ballast
pumps Pump rate
(m3/h) Total rate
(m3/h) Power
available
12 WBT 1 FPT 1 APT
23,891.6 2 WBP 2 GSP
750 280
1,500 560
730kw X
3sets
Tank No. Capacity(m3) Tank. No. Capacity(m3)
No.1 C.O.T.(P) 3450.9 F.P.T. 2423.2
No.2 C.O.T.(S) 3450.9 No.1 W.B.T.(P) 1796.0
No.2 C.O.T.(P) 4662.6 No.1 W.B.T.(S) 1541.8
No.2 C.O.T.(S) 4662.6 No.2 W.B.T.(P) 1795.2
No.3 C.O.T.(P) 4753.9 No.2 W.B.T.(S) 1541.0
No.3 C.O.T.(S) 4753.9 No.3 W.B.T.(P) 1775.8
No.4 C.O.T.(P) 4753.9 No.3 W.B.T.(S) 1521.6
No.4 C.O.T.(S) 4753.9 No.4 W.B.T.(P) 1777.1
No.5 C.O.T.(S) 4745.3 No.4 W.B.T.(S) 1521.6
No.5 C.O.T.(P) 4745.3 No.5 W.B,T.(P) 1758.0
No.6 C.O.T.(S) 4116.4 No.5 W.B,T.(S) 1503.8
No.6 C.O.T.(P) 4116.4 No.6 W.B,T.(P) 2267.7
SLOP T.(P) 599.4 No.6 W.B,T.(S) 1959.7
SLOP T.(S) 599.4 A.P.T 710.2
Residual Tank 105.0
Total 54269.8 Total 23892.7
Subject BWTS to study feasibility for retrofitting on Subject Vessel 4 Types BWTS chosen owing to charging mainly world market share
Beyond Compliance 9
Direct Flow Electrolysis Type Side-stream Electrolysis Type
Ultra Violet Type Ozone Injection Type
Case Study for Retrofitting BWTS on DWT 47K Oil/Chemical Tanker
General overview for subject vessel UV and direct flow electrolysis type BWTS is required to BWTS room Side stream electrolysis and ozone type BWTS is not required to BWTS room
Beyond Compliance 10
Concept for UV type & Direct Flow Electrolysis Type
Concept for Side-Stream Electrolysis Type Retrofit concept for Ozone type BWTS
Dangerous Zone Plan
Case Study for Retrofitting BWTS on DWT 47K Oil/Chemical Tanker
Costing analysis for CAPEX and OPEX Detailed items to consider CAPEX and OPEX are to be referred
Beyond Compliance 11
CAPEX
Additional equipment
Installation Support Work
Additional Installation costs
BWTS, Installation & Spaces
OPEX
Fuel Consumption
Power Requirement
Equipment maintenance
Case Study for Retrofitting BWTS on DWT 47K Oil/Chemical Tanker
Estimation cost divided 3 parts as Low, Probable and High on considering changeable price Ozone type is much higher, because power consumption, frequent maintenance
Beyond Compliance 12
Overall CAPEX for each BWTS Overall OPEX for each BWTS
Case Study for Retrofitting BWTS on DWT 47K Oil/Chemical Tanker
Trend of total accumulated operating cost during 23 years after BWTS is installed Side stream electrolysis type BWTS is the best choice From 11 years(ship’s age : 20 years) after installation, accumulated cost of direct flow electrolysis type is lower than ozone type BWTS
Beyond Compliance 13
Cost estimation-Low range Cost estimation-High range Cost estimation-Probable range
Case Study for Retrofitting BWTS on DWT 47K Oil/Chemical Tanker
BWTS Retrofit Experience and Engineering by KR
Beyond Compliance 14
BWTS Retrofit Experience and Engineering by KR
Record for installation BWTS on New Ship built in Shipyard(127 ships) BWTSs have been installed on various kinds of Ship since 2009
Beyond Compliance 15
1
20
7
1
44 8
9
14
1
20
2
BARGE
BULK CARRIER
CARGO SHIP
CHEMICAL TANKER
CONTAINER SHIP
LIQUEFIED GAS CARRIER
OIL TANKER
OIL/CHEMICAL TANKER
ORE/CHEMICAL CARRIER
RORO SHIP
SPECIAL PURPOSE SHIP
7
86
7
BWTS Retrofit Experience and Engineering by KR
Installation status of a kind of BWTS by main ship’s type Direct flow electrolysis and UV type are generally installed regardless ship type Side stream electrolysis and ozone type BWTS are generally installed to Oil Tanker
Beyond Compliance 16
55 35
10
Bulk Carrier(%)
45 48
7
Container Ship(%)
44
12
44
Oil Tanker(%)
25
50
25
Liquefied Gas Carrier(%)
Oil/Chemical Tanker(%)
BWTS Retrofit Experience and Engineering by KR
Analysis of characteristic for each type of BWTS Comparison with advantage and shortage for each BWTS
Beyond Compliance 17
UV Direct Flow Electrolysis
Advantage 1. Available to sail to fresh water zone 2. No effect on corrosion
1. Effectiveness for killing lives 2. Easier operation
Shortage 1. Effectiveness depending on turbidity of water 2. Treated by UV on De-ballasting Mode
1. limited fresh water zone sailing 2. Increasing power consumption on lower PSU, lower temp. of sea water 3. Effect on corrosion for ballast tank
Ozone Injection Side-Stream Electrolysis
Advantage 1. Available to sail to fresh water zone 2. Oil Tanker and Chemical Tanker 3. Better for large size of ship
1. Oil Tanker and Chemical Tanker 2. Large size of ship 3. Effectiveness for killing lives
Shortage
1. harmfulness for ship’s crew 2. Power Consumption 3. Worse for small size of ship owing to BWTS size 3. Effect on corrosion for ballast tank
1. limited fresh water zone sailing 2. increasing power consumption on lower PSU, lower temp. of sea water 3. Effect on corrosion for ballast tank
Engineering experience for Exiting Vessel using 3D scanning Technique Engineering experience for retrofitting 3 BWTS on bulk carrier
Beyond Compliance 18
BWTS Retrofit Experience and Engineering by KR
Bulk Carrier
L x B x D (m) : 284.23 X 45 X 24.7
DWT. 180,000 ton
Generator : 937KVA(750kW) X 4 sets
Two(2) Ballast Pump : 2,500㎥/h x 30m
Direct Flow Electrolysis BWMS Ultra Violet BWMS Ozone Injection BWMS
All process for using 3D scanning technique Totally 5 stages are main classified, described essential software information
Beyond Compliance 19
BWTS Retrofit Experience and Engineering by KR
3D Scan
3D Data Merging
PASSWAY SIMULATION
CRASH DETECTION
EQUIPMENT
STRUCTURE & COMPONENT
PIPE
PART MERGING & NEW PIPE CONNETION
DATA EXPORT & PRINT
Pre-processing 3D MODELING Post-processing VISUAL INSPECTION
As scan survey stage, analyzed available space to retrofit BWTS As pre-processing stage, 3D Data merging using “Scene” Software
Beyond Compliance 20
BWTS Retrofit Experience and Engineering by KR
Item
Scanning Range
Vertical Direction
Horizontal Direction
Point Cloud/Sec.
Scanning Time
Max.120m 300 Deg. 360 Deg. Abt.
970,000 10~15H
Scan survey 3D Data merging
As visual inspection stage, 3D data will be able to use “Visual simulation” “Autodesk”, “Navisworks” and “Simulation” Software will be used Checking any obstacle to install equipment of BWTS
Beyond Compliance 21
BWTS Retrofit Experience and Engineering by KR
Install Simulation
Crash Detect
Install simulation
Crash Detect
Install simulation
Crash Detect
UV Type Ozone Type Electrolysis Type
As 3D reverse modeling stage, classified with 3 parts(equipment, structure and pipe) First of all, equipment modeling worked using “Autodesk Inventor” S/W 2D manufacturer drawing to be converted as 3D modeling
Beyond Compliance 22
BWTS Retrofit Experience and Engineering by KR
3D modeling drawing
2D manufacturer drawing
UV Type Ozone Type Electrolysis Type
3D modeling drawing
2D manufacturer drawing
3D modeling drawing
2D manufacturer drawing
Structure modeling worked using “AutoCAD” Software 3D structure modeling data is available to develop MA and Installation DWG
Beyond Compliance 23
BWTS Retrofit Experience and Engineering by KR
Pipe 3D modeling worked using “EdgeWise” Software Pipe 3D modeling data is available to develop pipe and fittings DWG
Beyond Compliance 24
BWTS Retrofit Experience and Engineering by KR
As Post-processing stage, 3D modeling as equipment, structure and pipe merged to use “AutoCAD Plant 3D” Software Preparing new P&ID for ballasting system, manufacturer’s DWG
Beyond Compliance 25
BWTS Retrofit Experience and Engineering by KR
UV Type Ozone Type Electrolysis Type
Beyond Compliance 26
BWTS Retrofit Experience and Engineering by KR
Oil/Chemical Tanker L x B x D (m) : 80.4 x 14.0 x 7.3 DWT. 3,400 ton Generator : 325 KVA(260kW) x 3 sets One(1) Ballast Pump : 200㎥/h x 25m
1,600 TEU Container Vessel L x B x D (m) : 159.5 X 27.2 X 13.8 DWT. 20,999 ton Generator : 875 KVA(700kW) X 3 sets Two (2) Ballast Pump : 300㎥/h x 20m
Bulk Carrier L x B x D (m) : 216.55 X 32.24 X 19.1 DWT. 72,875 ton Generator : 625KVA(500kW) X 3 sets Two(2) Ballast Pump : 1,000㎥/h x 25m
Direct Flow Electrolysis BWMS Ultra Violet BWMS Ozone Injection BWMS
Engineering experience for Exiting Vessel not using 3D scanning Technique Engineering experience for retrofitting 3 BWTS on each subject vessels
Beyond Compliance 27
BWTS Retrofit Experience and Engineering by KR
Size of component for each BWTS to be measured Next, analysis of available spaces to retrofit BWTS onboard Preparing machinery arrangement and Arr’t of electric equipment
Beyond Compliance 28
BWTS Retrofit Experience and Engineering by KR
After onboard survey is completed, producing revised MA reflecting BWTS Below 3 revised MA for each ship are shown for retrofitting direct flow Electrolysis BWTS
Oil/Chemical Tanker
Bulk Carrier
Container Ship
Beyond Compliance 29
BWTS Retrofit Experience and Engineering by KR
After machinery arrangement is completed, ballast piping diagram to be revised Revised ballasting piping diagram to be reflected operating system, suitable valve and instrument for BWTS Below 2 revised ballast pipe diagram for each ship are shown for retrofitting direct flow Electrolysis BWTS
Oil/Chemical Tanker Bulk Carrier
After ballast pipe diagram is completed, Preparing for manufacturer’s drawing based on piping arrangement drawing, size and length of pipes, various fittings
Beyond Compliance 30
BWTS Retrofit Experience and Engineering by KR
Oil/Chemical Tanker Bulk Carrier Container Ship
Preparing ELA(Electric Load Analysis) depending on power consumption Preparing revised electric wiring diagram according to retrofitting BWTS Variation of continuous load data on working service is 4% Consequently, not necessary to additionally install generator and engine
Beyond Compliance 31
BWTS Retrofit Experience and Engineering by KR
Before After
Analysis of the lightship data after retrofitting BWTS(oil/chemical tanker) Calculate weight of BWTS, all fittings including pipes and valves Confirm whether deviation of lightweight between before and after retrofit BWTS
Beyond Compliance 32
BWTS Retrofit Experience and Engineering by KR
ITEM WEIGHT(Ton) LCG(m) L-Moment (Ton-m)
VCG(m) V-Moment (Ton-m)
LIGHTSHIP(OLD) 1632.980 -7.481 -12216.32 6.527 10658.46
PDE 0.377 -28.835 -10.87 8.450 3.19
EX-ECU 0.230 -21.05 -4.84 4.140 0.95
HEU 0.137 -20.145 -2.76 4.950 0.68
DTU 0.108 -20.125 -2.17 5.050 0.55
TSU 0.145 -21.865 -3.17 6.050 0.88
ANU 0.380 -36.00 -13.68 11.000 4.18
GEU 0.034 -20.050 -0.68 7.650 0.26
PIPE-15A (Sch.80) 0.036 -28.896 -1.04 6.346 0.23
PIPE-15A (Sch.80) 0.018 -21.393 -0.39 3.814 0.07
PIPE-25A (Sch.20) 0.021 -20.149 -0.42 13.250 0.28
PIPE-40A (Sch.80) 0.071 -20.676 -1.47 4.761 0.34
PIPE-50A (Sch.80) 0.112 -21.226 -2.38 3.641 0.41
PIPE-200A (Sch.80) & VALVES
0.497 -21.08 -10.48 3.194 1.59
TOTAL LIGHTSHIP(NEW)
1635.146 -7.504 -122270.67 6.527 10672.07
Comparison with “scan survey” and “onboard survey” demanded time for process In case “scan survey”, time for total retrofit process is saved about 5weeks
Beyond Compliance 33
BWTS Retrofit Experience and Engineering by KR
Man 1 Month 2 Month 3 Month
1W 2W 3W 4W 1W 2W 3W 4W 1W 2W 3W 4W
Onboard Survey 2
Scan Survey 2
System Engineering 2
Preparing installation drawing 2
Approval from Class KR
Retrofit work at dock -
Inspect BWTS with Class, Ship Owner and Manufacturer
3
: Onboard survey : Scan survey
Technical Service to Retrofitting BWTS for Shipping Company
Beyond Compliance 34
As implementing feasibility study for retrofitting BWTS, We can totally consult and Recommend the best optimized BWTS on your Vessel As using 3D scanning technologic, We can serve total engineering for retrofitting BWTS on your existing vessels
We can serve the highest quality survey for retrofitting BWTS on your vessels
With KR, You can surely save time and cost for successfully retrofitting BWTS
Beyond Compliance 35
Technical Service to Retrofitting BWTS for Shipping Company
Recommended