Automatic Weather StationAWS310‑SITE

Features

• Designed and tested for aviationapplications with Vaisala AviMetâ

systems

• Complete solution for weatherdata collection

• Wide range of installation, powersupply, and communicationoptions

• ICAO- and WMO-compliantsensors with long calibrationintervals

• Surge protection for power input,sensor connections, and outputdata connections

Optimized for Airport WeatherObservation NeedsAWS310‑SITE is specially designed andtested for Vaisala AviMet AutomatedWeather Observing System (AWOS) andLow‑level Windshear Alert System(LLWAS), ensuring complete end‑to‑endsystem integration. With Vaisala AviMet,users are able to collect and viewweather data remotely, as well asmonitor and control the AWS310‑SITEobservation stations.

A Complete SolutionThe AWS310‑SITE solution includeseverything required for accurate andreliable weather measurements: theenclosure, a wide variety of sensoroptions, installation kits, power supply,and communication devices.

The solution has a robust, tightly sealedIP66 stainless steel (AISI 316) enclosureto protect the electronics. AWS310‑SITEis available with different installation andpowering options according to customerneeds and site requirements, including asolar-powered option for remotelocations.

The AWS Client software is included formaintenance purposes to support setup,diagnostics, and data retrieval.

Data CollectionMeteorological data is sent to the airportweather observation system in real time.There are several standardcommunication options available,including landline communicationthrough RS‑232, RS‑485, or leased-linemodem, or wireless communicationthrough a UHF/VHF radio interface.

To provide redundancy in safety-criticalairport applications, data can be sentsimultaneously via 2 parallelcommunication ports. The data is alsosaved on the weather station’s externalmemory card. The stored log files can beexported to external applications.

Excellent Long-term StabilitySensor calibration is vital to accurate andreliable observations. The sensors ofAWS310‑SITE ensure excellent long-termstability with a low risk of drift or suddenchanges in calibration. This results inlonger calibration intervals, lowermaintenance costs, and reduceddowntime.

Installation OptionsThere are several standard masts andmast installation kits available forAWS310‑SITE. Frangible options includepole masts DKE110F, DKP721, and DKP711and lattice mast DKE200. Vaisalafrangible masts are impact-tested, andthey comply with the frangibilityrequirements set in the followingspecifications:

• ICAO Doc 9157 Aerodrome DesignManual, Part 6 Frangibility, FirstEdition, 2006

• FAA AC 150/5345‑45C – Low ImpactResistant Structures, 2007

Standard Safety FeaturesAWS310‑SITE includes surge protectionfor the power input, sensor connections,and output data connections. Surgearrestors protect the AWS310‑SITE unitfrom potential damage caused by pooror variable power quality, or otherpossible surges.

Vaisala Automatic Weather Station AWS310‑SITE is anautomatic weather station that is optimized for airportweather observations. Based on the proven VaisalaAWS310 weather station, AWS310‑SITE provides reliableand accurate weather measurements for aviationapplications using ICAO- and WMO-compliant sensors.

Technical Data

Operating EnvironmentOperating temperature −40 ... +60 °C (−40 ... +140 °F) 1)

Storage temperature −60 ... +70 °C (−76 ... +158 °F) 2)

Operating humidity 0 ... 100 % RH

1) For internal battery storage and operating temperature range, see manufacturer documentation.2) Excluding HMP155.

Environmental Compliance

Test Applied Standardor Test Procedure

Specification

Operation

Dry heat IEC 60068-2-2 +60 °C (+140 °F)

Cold IEC 60068-2-1 −40 °C (−40 °F)

Damp heat IEC 60068-2-30 +40 °C (+104 °F) / 85 ... 95 %RH

Vibration IEC 60068-2-6 0.7 g (0.025 oz) 10 ... 200 Hz2 ... 9 Hz to 200 Hz, 1.5 mm(0.06 in) displacement

Shock IEC 60068-2-27 5.0 g (0.18 oz)Pulse duration 11 ms with100 pulses in each direction

Storage

Dry heat IEC 60068-2-2 +80 °C (+176 °F)

Cold IEC 60068-2-1 −60 °C (−76 °F)

Damp heat IEC 60068-2-30 +40 °C (+104 °F) / 85 ... 95 %RH

Transport

Vibration (random) IEC 60068-2-64 Random

Rough handling IEC 600068-2-31 Drop height 60 cm (23.62 in)

EMC Compliance

Test Applied Standardor Test Procedure

Specification

Electrostatic discharge EN 61000-4-2 4 kV contact, 8 kV air

Fast transient burst EN 61000-4-4 2 kV AC, 1 kV I/O, and DC

RF field immunity(80 MHz ... 6 GHz)

EN 61000-4-3 11 V/m (80 MHz ... 1 GHz)4 V/m (1 GHz ... 2 GHz)2 V/m (2 GHz ... 6 GHz)

Conducted RFimmunity

EN 61000-4-6 4 V e.m.f. (150 kHz ... 80 MHz)

Immunity to voltagedips and shortinterrupts

IEC 61000-4-11 0 % 1 cycle40 % 10 cycles70 % 25 cycles0 % 250 cycles

Powering SpecificationsAC (mains) power 100 ... 240 VAC, 50 ... 60 Hz

5.6 A maximum (120 VAC)

External power 15.5 ... 30 VDC6 A maximum

Internal backup battery 12 V / 26 Ah or 12 V / 52 Ah

Mains fuse (nominal) 10 A minimum

Solar panel 70 W

BOX652 SpecificationsIP rating IP66

Material Stainless steel AISI 316, painted white

Size (enclosure only) 600 × 500 × 207 mm(23.62 × 19.68 × 8.15 in)

Weight Approximately 30 kg (66 lb)

Maximum wind speed 75 m/s (168 mph)

Standard Sensor OptionsWind speed and direction WMT700, WA15 (dual sensors

available)

Air temperature and relative humidity HMP155

Barometric pressure PTB330 (Class A accuracy, with3 transducers)

Global solar radiation SMP3, SMP6, SMP10

Sunshine duration CSD3

Rain/Precipitation RG13(H), OTT Pluvio2 L

Runway temperature DRS511

Runway temperature and surface state RWCC

Ground temperature QMT107

Soil temperature QMT110

Standard interface CL31, LT31, FS11, FS11P, PWD22,TSS928

Standard Communication OptionsLandline communication RS‑232, RS‑485, or leased-line

modem

Wireless communication UHF/VHF radio interface

Fiber optic communication With Vaisala Field CommunicationBox FOC201 or customer-providedsolution

Dual communication Any combination of 2 standardcommunication options

Standard Accessories2 enclosure locks

USB maintenance cable

2 removable 2 GB CF memory cards

Optional AccessoriesObelux Obstruction Light QOL111

Vaisala TERMBOX‑1200 for mains power and 1 data line

Vaisala TERMBOX‑1212 for mains power and 2 data lines

Vaisala Fixed Display QMD202 inside the enclosure

Installation kits for:• 100 mm (3.94 in) pole mast (DKP210)• 106 mm (4.17 in) frangible pole mast (DKE110F, DKP721, DKP711)• Frangible lattice mast (DKE200)

Published by Vaisala | B211652EN-B © Vaisala 2018

All rights reserved. Any logos and/or product names are trademarks ofVaisala or its individual partners. Any reproduction, transfer, distributionor storage of information contained in this document is strictlyprohibited. All specifications — technical included — are subject tochange without notice.www.vaisala.com