Certificate Number 8566EA
Certificate OfCalibration
The Antenna(s) has been individually calibrated using the following standard procedure(s):
ARP-958D and/or IEEE 291 and lor ANSI C63.5-2006
Calibration Traceability: All measurement instrumentation traceable to the ational Institute of
Standards and Technology (NIST)
Calibration is lAW ANSI/NCSL Z540-1-1994 and ISO 17025
NIST Numbers: DCV 811124944-92, ACV 5211234615, n 811/250891
Dimensional 821/253616-94, WWWBoulder, CO
Calibration Uncertainty: +1- IdBEnvironment:
Manufacturer
Temperature: 78 Degrees Fahrenheit
Humidity: 36% (non-condensing)
Model Number Serial Number Date of Calibration
ATM
ATM
90-441-6/BR/CAL H548509-0 I
90-251A-6 H548609-0 I
26-0ct-07
26-0ct-07
Re-Certification Date: 1 year from calibration date
tV drb fI ra Ion ;qUlpmen seModel Serial Calibration Model Serial Calibration
Number Number Due Date Number Number Due Dale
HP-8563E 3551A04250 4-Sep-08 [ ] HP-85620A 01282 8-Jan-08
HP-85644A 3407A00167 27-Apr-08 [ ] HP-3325A 1625A00598 27-Apr-08
HP-8673D 2747A00701 8-Jan-08 [ ] HP-8620C 1604A00368 27-Apr-08
HP-11970A 2332A02615 8-Jan-08
M-AD1020P 0216 8-Jan-08
[XI
[ I[XI
[ I[ I
Antenna ConditionPre Calibration:
In tolerance [ ]Out of tolerance []
Repair required [ ]
Repair performed [ ]
Special Limitations: bDavid Habermann
Quality Control Manager
Post Calibration:
Meets all specs [X]Limited specs [ ]
Other []
This certificate shall not be reproduced except in full, without written approval of Advanced Technical Materials Inc
8/3/2019 ATM Calibration Report
http://slidepdf.com/reader/full/atm-calibration-report 2/3
ADVANCED TECHNICAL MATERIALS, INC.49 Rider Avenue, Patchogue, NY 11772
Tel: 631 289-0363 • Fax: 631 289-0358Web: www.atmmicrowave.com
Horizontal Polarization (Far-Field)
1 Meter Calibration, Horn Antenna
e-mail: atm@atmmicrowave.com
Model: 90-441-6/BRiCAL
Model: 90-251A-6
Serial Nwnber: H548509-01
Serial umber: H548609-0 I
Date: 26-0ct-07
Date: 26-0ct-07
Frequency Antenna Factor Gain Gain(MHz) (dB/m) (dBi) (Numeric)
8200 34.91 13.61 22.96
8300 34.72 13.91 24.62
8400 34.69 14.04 25.38
8500 34.61 14.23 26.46
8600 34.57 14.36 27.30
8700 34.50 14.54 28.42
8800 34.71 14.42 27.68
8900 34.68 14.55 28.51
9000 34.61 14.72 29.68
9100 34.45 14.98 31.46
9200 34.58 14.94 31.22
9300 35.00 14.62 28.95
9400 34.92 14.79 30.12
9500 34.84 14.96 31.32
9600 34.60 15.29 33.84
9700 34.85 15.13 32.62
9800 35.03 15.04 31.949900 35.06 15.10 32.34
10000 34.69 15.55 35.91
10100 34.82 15.51 35.60
10200 35.03 15.39 34.62
Add antenna factor plus cable loss to receiver reading in dBuV
to convert to field intensity in dBuVImeter. Calibrate per
SAE ARP-958 and/or ANSI C63.5 and/or IEEE 291