AS2204 – Multi-Channel SD Encoder Quick Start Guide
Step 1: Unpack your Kyrion® unit and carefully slide it into a shelf space in the rack. Use
your equipment rack’s screws to secure the device in place. Step 2: Connect the Kyrion
® System to a power outlet using the provided power cord.
Step 3: Connect the network cables to Ethernet interfaces. � The Stream interfaces should be plugged to your broadcast network � The MGT (management) interface should be plugged to your supervision
network Step 4: Connect the HD-SDI input cable and eventually one or more ASI outputs. Step 5: Power up the Kyrion
®, switching the 0/1 button in the 1 position.
� After a few seconds, ATEME logo should appear on the LCD. � The front Panel selection menu appears when the unit is up and running.
2 Setup Your Kyrion®
This product package should contain the following items: � One (1) Kyrion
®.
� One (1) Power Cord. � One (1) CD ROM. � User’s Manual.
If any item is missing, please contact your place of purchase immediately.
1 Check Package content
Step 4
Step 1
Unpack
Connect power
Connect Management LAN and Broadcast LANs
Connect SD-SDI in
Power ON
Step 2
Step 5
Step 3
Step 6: Use Roller Touch PAD and LCD on the Kyrion® unit to configure your
IP addresses, default gateways and basic Encoding settings.
3 Configure Your Kyrion ®
Configure IP addresses
Step 6
Multi Channel SD MPEG-4/AVC ENCODER
Doc. Ref: 0900082-QSG1
Step 7: From this point on, you should be able to access advanced parameters of the Kyrion Encoder from any remote Computer using a standard Web Browser and the IP address you set in Step 6.
4 Fine Tune settings
Your Kyrion® is UP and READY to Broadcast!