5/18/2018 Arjo Freedom Bath Manual
1/48
Freedom Bath
...with people in mind
0086
INSTRUCTIONS FOR USE
04.AF.02_11US.CA . Juni 2013
5/18/2018 Arjo Freedom Bath Manual
2/48
WARNINGTo avoid in jury, always read this Instructions for Use and accompanied documentsbefore using the product .
Mandatory to read the Instructions for Use
Design Policy and Copyright and are trademarks belonging to the ArjoHuntleigh group of companies. ArjoHuntleigh 2013.
As our policy is one of continuous improvement, we reserve the right to modify designs
without prior notice.The content of this publication may not be copied either whole or inpart without the consent of ArjoHuntleigh.
5/18/2018 Arjo Freedom Bath Manual
3/48
3
Contents
Foreword ..........................................................................4
Intended Use .................................................................... 5
Safety Instructions ............................................................ 6
Preparations ..................................................................... 7
Parts Designation ............................................................. 8
Control Panel, External Water Supply ............................ 10
Control Panel, Built-In Water Supply .............................. 12
Product Description/Function ......................................... 14
Power Assisted Door Operation ..................................... 16
Operating Assisted Bathing ......................................... 17
Air Spa Operation (optional) ........................................... 20
Waste Water Pan ........................................................... 21
Home Care Use .............................................................. 22
Cleaning and Disinfection Instructions ........................... 24
Care and Preventive Maintenance ................................. 28
Troubleshooting .............................................................. 32
Technical Specifications ................................................. 34
Labels on the Freedom Bath .......................................... 38
Approvals and List of Standards ..................................... 40
Electromagnetic Compatibility ........................................ 42
Parts and Accessories .................................................... 46
ArjoHuntleigh Addresses .................................... Last page
5/18/2018 Arjo Freedom Bath Manual
4/48
4
Foreword
Thank you for purchasing ArjoHuntleighEquipment.Your Freedom Bathis part of a world-wide family of
quality products designed especially for assisted
living facilities, group homes, retirement facilities,moderately dependent nursing care and in homes
wherever limited assistance or independent bathing
equipment is desired.
Please contact us if you have any questions about the
operation or maintenance of your Freedom Bath.
Please read this Instructions for Usethoroughly!
Please read thisInstructions for Use (IFU)in itsentirety before using your Freedom Bath.
Information in theIFUis crucial to the properoperation and maintenance of the equipment, andwill help protect your product and make sure that theequipment performs to your satisfaction. Some of theinformation in thisIFUis important for your safetyand must be read and understood to help prevent
possible injury.
Unauthorized modifications on any ArjoHuntleighequipment may affect its safety. ArjoHuntleigh willnot be held responsible for any accidents, incidentsor lack of performance that occur as a result of any
unauthorized modification to its products.
Report Unexpected Operations orEventsContact your local ArjoHuntleigh representative if
any unexpected operations or events occur. The
contact information appear on the last page of this
IFU.
Service and SupportA service routine must be performed on your
Freedom Bathevery year by ArjoHuntleigh
authorized service personnel to ensure continued safe
operation of your product.
See sectionCare and Preventive Maintenance.
If you require further information, please contactyour local ArjoHuntleigh representative who canoffer comprehensive support and service programs tomaximize the long-term safety, reliability and valueof the product.
Contact your local ArjoHuntleigh representative forreplacement parts. Your service representative stocksthe parts you will need. The contact informationappears on the last page of thisIFU.
Definitions in this IFU:
Means:
Safety warning. Failure to understand and obey this
warning may result in injury to you or to others
Means:
Failure to follow these instructions may cause
damage to all or parts of the system.
Means:
This is important information for the correct use of
this system or equipment.
Means:The name and address of the manufacturer
WARNING
CAUTION
NOTE
5/18/2018 Arjo Freedom Bath Manual
5/48
5
Intended Use
This equipment must be used in accordance withthese safety instructions.
Anyone using th is equipment must also have readand understood the instruct ions in this Instructions
for Use (IFU).If there is anything you are not sure about, ask yourAr joHunt leigh representative.
Freedom bathis intended for therapeutic bathing and
showering of adult residents in care facilities or in home care
environment.
The bath must be used by appropriately trained caregivers with
adequate knowledge of the care environment, its common
practices and procedures, and in accordance with the
guidelines in theInstructions for Use (IFU).
Indication for UseThis bath is used for general cleaning and relaxation and for
hydrotherapy to relieve pain and itching and as an aid in the
healing process of inflamed and traumatized tissue, and it
serves as a setting for removal of contaminated tissue.
This equipment should only be used for the purpose specified
in thisInstructions for Use (IFU). Any other use is prohibited.
Resident Assessment
We recommend that facilities establish regular assessmentroutines. Caregivers must assess each resident according to the
following criteria prior to use:
The resident must be able to sit in an upright position, nor-
mally defined as active or semi-active.
The residents weight must not exceed 160 kg (352 lbs).
The resident must understand and be able to respond to
instructions to stay seated in an upright position.
If a resident does not meet these criteria an alternative
equipment/system should be used.
Lifetime of the EquipmentThe equipment must be installed by appropriately trained
personnel according to the Assembly and Installation
Instructions. Requirements in the Assembly and Installation
Instructions can only be superseded by local code.
The lifetime of this equipment is ten (10) years and the service
life of the support strap (optional) is two (2) years. The lifetime
and service life are stated providing that the preventive
maintenance are being carried out in accordance with theinstructions for care and maintenance in theInstructions for
use (IFU). This bath system must only be used for the purpose
specified here.
5/18/2018 Arjo Freedom Bath Manual
6/48
6
Safety Instructions
WARNINGTo avoid injury, make sure that the resident is not
left unattended at any time.
WARNINGTo avoid electric shock, never use other electr icalequipment near this device.
WARNINGTo avoid explosion or fi re, never use the equipmentin oxygen rich environment, in presence of heatsource or flammable anaesthetic gases.
CAUTIONNever drop or insert any object into any opening.Do not probe into the drain with any pointed orsharp object.
Do not force door down before tub empties anddoor seal deflates.
NOTEPressing the emergency seal release valve with waterin the tub will cause the water to spill onto the bathroomfloor.
If the door is not fully raised, the drain will remain open.
If the fully raised door is forced down, the drain willopen.The fully raised door will remain sealed as long as waterremains in the tub and the emergency door seal releasevalve is not activated.
In the event of an AC power failure, the drain will openbut the seal will remain inflated until the emergency sealrelease valve is activated.
5/18/2018 Arjo Freedom Bath Manual
7/48
7
Preparations
Site PreparationsPrior to installation of Freedom Baththe floorand walls within the required area must befinished.
Material: The floor should be made of a slip-resistantmaterial, free of bumps.
Floor slope: When using a floor drain, the slopetowards the drain should not exceed 1:50.
Floor attachments:The floor construction must besuitable for anchoring the bolts.
Actions Before the First Use (9 Steps)1 Make sure that the bath has been installed
according to theAssembly and Installation
Instructions.
2 Check that all parts of the product are supplied.
Compare with the Parts Designationpage in this
IFU. If any part is missing or damaged - do NOT
use the product.
3 Read theIFU.
4 Disinfect the product according toDisinfection
Instructionsin thisIFU.5 Perform a functionality test according to Care and
Preventive Maintenancein thisIFU.
6 Choose a designated area, where theIFUshould
be kept and is easily accessible at all times.
8 Make sure the thermostatic mixer has been
calibrated according to theAssembly and
Installation Instructionsby an ArjoHuntleigh
service technician.
9 Make sure to have a rescue plan ready in case of a
resident emergency.
7 WARNINGTo prevent scalding, make sure that thewater mixer has been calibrated.
Confirm that responsible organizationhas established calibration routines.
Actions Before Every Use (4 Steps)1 Check that all parts are in place. Compare to Parts
Designationpage in thisIFU.
2 Check bath and accessories for damage.
3 If any part is missing or damaged - do NOT use
the product.
4 WARNINGTo prevent cross-contamination, alwaysfollow the disinfection instructions inthis Instructions for Use.
NOTE
If you have any questions, please contact yourlocal ArjoHuntleigh representative for supportand service. The contact information(ArjoHuntleigh addresses)is listed on the lastpage of this IFU.
5/18/2018 Arjo Freedom Bath Manual
8/48
8
Parts Designation
Freedom BathIncludes the Following Parts:(See Fig. 1)
1 Roll-Door
2 Covers for service access (2)3 Low water level sensors (2)
4 Emergency seal release
5 Drain
6 Assist handle
7 Inflatable sealing system (inside the cover)
8 Seat
9 Waste water pan (underneth the tub)
10 Shower
11 Tub fill spout
12 Thermostatic water control system (optional)
13 Control panel
14 High water level sensor (optional)
15 Surface overflow outlet
16 Support strap (optional)
Air Spa (opt ional ) (See Fig. 2)17 Control panel18 Disinfectant fill port for MultiClean (optional)
19 High water level sensor (1)
20 Air nozzles (12)
Applied part: Type BRoll door. including the complete tub.Protection against electrical shock in
accordance with IEC 60601-1.
5/18/2018 Arjo Freedom Bath Manual
9/48
9
1 12 13 10 6 11 4
14
2
9
7
8 3 5
17
16
18
19
1
2
20
15
5/18/2018 Arjo Freedom Bath Manual
10/48
10
Control Panel, External Water Supply
Control Panel - Still Bath (6 steps)1 Door - UP
2 Door seal/ Drain
3 LED- flashes during sealing operation
- steady green light when sealing is activated
4 Door - DOWN
5 Shows water temperature in tub.
6 LED, steady red light when all buttons are locked.
Activates/releases when button 1 and button 4 are pushed at
the same time for 1 second.
Control Panel - Air Spa (8 steps)1 Door - UP
2 Door seal / Drain
3 LED
- flashes during sealing operation
- steady green light when sealing is activated
4 Door - DOWN
5 Shows water temperature in tub.
6 LED, steady red light when all buttons are locked.
Activates/releases when button 1 and button 4 are pushed at
the same time for 1 second.
7 Air spa- START/STOP.
Five minutes after the tub is emptied, the air-
blower activates for 60 seconds (not in combination with
MultiClean).
8 Air spa- INCREASE/DECREASE
AIR SPEED.
5/18/2018 Arjo Freedom Bath Manual
11/48
11
F r e e d o m B a t h
Control Panel - Still Bath
6
1 2 4 53
Control Panel - Air Spa
F r e e d o m B a t h
1 2 3 4 5
6 7 8
5/18/2018 Arjo Freedom Bath Manual
12/48
12
Control Panel, Built-In Water Supply
Control Panel - Still Bath1 Door - UP.
2 Door seal / Drain
3 LED- flashes during sealing operation.
- steady green light when sealing is activated.
4 Door - DOWN.
5 Shows water temperature (measured in the
thermostatic mixer).
6 Tub filling
7 LED, steady red light when all buttons are locked.
Activates/releases when button 1 and button 4 are pushed at
the same time for 1 second.
8 Resident shower
9 Mixer knob - INCREASE/DECREASE
TUBWATER TEMPERATURE
Control Panel - Air Spa1 Door - UP.
2 Door seal / Drain
3 LED
- flashes during sealing operation.
- steady green light when sealing is activated.
4 Door - DOWN.
5 Shows water temperature (measured in the
thermostatic mixer).
6 Tub filling.
7 LED, steady red light when all buttons are locked.
Activates/releases when button 1 and button 4 are pushed at
the same time for 1 second.
8 Resident shower.
9 Air spa- START/STOP.
Five minutes after the tub is emptied, the air-
blower activates for 60 seconds (not in combination with
MultiClean).
10 Air spa- INCREASE/DECREASE
AIR-SPEED.
11 Mixer knob - INCREASE/DECREASE
TUBWATER TEMPERATURE.
5/18/2018 Arjo Freedom Bath Manual
13/48
13
Freedom Bath
Control Panel - Still Bath
1 2 3 4 5
6 7 8 9
Freedom Bath
Control Panel - Air Spa
1 2 3 4 5
76 8 9 10 11
5/18/2018 Arjo Freedom Bath Manual
14/48
14
Product Description/Function
Power Operated DoorThe power operated door has a gear motor which is
operated from the control panel. The motor incorporates a push
and hold feature and a safety clutch for user safety. The clutch
disengages when the control button is released, permitting thedoor to be opened in a manual mode, but should only be used
in emergency.
In case of power failure the door can be opened manually when
pushing the emergency button. (See Fig. 1)
Still Bath/Air SpaThe Freedom Bathis available with or without an air spa
system. A low-water sensor will prevent the air spa systemfrom being activated until the water in the tub is at a proper
operating level.
See sectionAir Spa User Instructions.
Control PanelThe control panel controls all tub functions and displays useful
information such as bath temperature.
(See Fig. 2)
Inflatable Door SealAn inflatable sealing system makes the door totally watertight.
The sealing is operated by a button on the control panel
and should be activated after the door is raised. (See Fig. 3)
NOTE
When theFreedom Bath is not in use, it is best for thedoor to be left in the up (closed) position, with the sealnot inflated.
Fig. 1
Fig. 2
Fig. 3
5/18/2018 Arjo Freedom Bath Manual
15/48
15
Automatic DrainThe drain is automatically activated in conjunction with the
sealing system only when the door is fully raised. When the
sealing system is deactivated, the drain is open. (See Fig. 1)
Lift-Accessible ModelThe L-A model series accommodates the needs of both the
ambulatory user and those requiring lift-transfer.
Maintenance AccessThere are two openings with covers for service and cleaning
access. (See Fig. 2)
Support Strap (optional)An optional strap is available to give the resident extra security
when necessary.
There are two possible ways to fasten. (See Fig. 3)
Adjust the length by pulling the safety belt end by the clip.
Cleaning/DisinfectionOptional cleaning system is available as a separate
system, MultiClean.
EmergencyIf an emergency situation occurs when a resident is in the
bathtub, press the emergency button to open the drain and
release the door (the water will rush out around the door).
The door can now be manually pushed down.
Fig. 1
Fig. 2
Fig. 3
5/18/2018 Arjo Freedom Bath Manual
16/48
16
Power Assisted Door Operation
Standard1 To raise the door, press and hold the button on the con-
trol panel. The door stops automatically when end position
is reached.
2 To lower the door, press and hold the button on the
control panel. The door stops automatically when end
position is reached.
3 In an emergency situation the door may be pushed down
manually after pressing the emergency seal release button.
4 The door will not operate in power mode if any of the
following conditions exist:
The seal is ON.
The control panel is locked.
Lift Accessible, LA (optional)Integration with ArjoHuntleigh standing and raising aid lifts
such as Stedy, Sarita, Sara, Encore and Chorus is possible. The
lift accessible area under the tub is shown in the illustration.
(See Fig. 1)
1 To raise the door, press and hold the button on the con-
trol panel. The door stops automatically when end position
is achieved.
2 To lower the door, press and hold the button on thecontrol panel. The door stops automatically in a low
position. When docking with a patient lift, push the
button again and the door will proceed moving in
under the tub and automatically stops in the end position.
3 In an emergency situation the door may be pushed down
manually after pressing the emergency seal release button.
4 The door will not operate in power mode if any of the
following conditions exist:
The seal is ON.
The control panel is locked.
WARNINGTo avoid entrapment of the residents or caregiverslegs or feet, make sure that they are kept c lear of allobstacles. (See Fig. 2)
Fig. 1
1100mm43"
155mm6"
410 mm 16"
Fig. 2
5/18/2018 Arjo Freedom Bath Manual
17/48
17
Operating Assisted Bathing/Showering
Assisted Bathing
The Freedom Bath is also ideal for assisted bathing. All
controls are positioned for convenient use by the caregiver.
If necessary it is possible to lock the panel functions to avoid
unauthorized use. See sectionControl Panel, External Water
Supply.
Start the Bathing/Showering (7 steps)ArjoHuntleigh Liquid bathing products have been developed
for use with the Freedom Bathand are recommended.
1 Lower the door to its lowest position.
Clear all obstacles from the path of the door.
2 Help the bather to sit comfortably on the bath seat.
(See Fig. 1)
3 Bathing:
Raise the door to the top position. (See Fig. 2)
continue with the steps on the next page
WARNING
To prevent scalding, always check the watertemperature with your naked hand before directingthe water on the resident. Do note use gloves at it
may insulate to the extent that the watertemperature can be misjudged. Point the flow of thewater away from the resident.
WARNING
To avoid entrapment, make sure to keep theresidents hair, arms and feet close to the body anduse designated grab supports during anymovement.
Fig. 1
Fig. 2
5/18/2018 Arjo Freedom Bath Manual
18/48
18
Showering:
Raise the door but leave the door down at least an inch (25
mm) (A) from the top position to prevent the drain from
closing. (See Fig. 3)
A lower position of the door will give more convenient
access to the lower part of the bather. (See Fig. 4)
4 Momentarily press the seal/drain button and the LED
above the button will flash with a green light. When the
door seal has reached proper inflation, the compressor will
stop and a steady green light will indicate that the seal
system is activated.
5 Bathing:
Press the tub filling button and fill the tub with water
of desired temperature. (See Fig. 5)
Showering:
Press the resident shower button and shower the resident
with desired temperature.
NOTE
Do not proceed with the operation if the compressorcontinues to run for longer than 60 seconds, or starts
and stops frequently.
NOTE
To accelerate the tub filling it is possible to start filling25 seconds after pushing the seal/drain button bypushing the fill button.(The 25 second delay is electronic and the filling andshower functions are locked out until 25 seconds haselapsed since the seal button was pushed).
If equipped with optional drain pan pump, this willstart operating when the door seal is deflated. Avarying sound level is normal during the operation.
Fig. 3
1" (25 mm)
A
Fig. 4
Fig. 5
5/18/2018 Arjo Freedom Bath Manual
19/48
19
End the Bathing/Showering (4 steps)
1 At completion of bath, press the seal/drain button . The
drain will open and the water drains. The seal is still inflated
and showering is suitable in this position with the door up.
2 Press the seal/drain button again to deflate the seal.
During the deflating process the LED above the button willbe flashing green light.
3 See that limbs of the resident are kept out of the sealing area
and the door path.
4 Lower the door by holding the door down button
depressed.
EMERGENCY (2 steps)1 In the event of medical emergency, open the lid covering the
emergency seal release and push the button, then push down
on the door. (See Fig. 1)
2 In the event of a power failure, wait for the tub to drain
completely before activating the emergency seal release.
NOTE
If the bather has both of their feet in contact with bothof the water sensors at the same time, the seal maynot deflate.
NOTE
The emergency seal release should only be used inemergency, because the water will spill out onto thebathroom floor.
Fig. 1EMERGENCY
5/18/2018 Arjo Freedom Bath Manual
20/48
20
Air Spa Operation (optional)
Check Before Usage: The door is fully raised.
The tub is filled above the high water level sensor button.
1 Press the Air spa ON/OFF button on the display and the air
blower will start in maximum speed. The blower will stop
by pressing the ON/OFF button again.
2 The intensity of the air spa bubbling action can be reducedby pressing and holding-in the blower speed control symbol
on the display. Release the button when the desired intensity
is reached. The blower speed can be changed at any time.
3 After completing the air spa, wash & shampoo or drain the
tub if bathing is complete.
4 Press the seal/drain button to open the drain. Allow the
water to drain below the low water level sensor buttons.
Once again press the seal/drain button and the seal will
deflate and the door can be lowered.
5 Clean/disinfect the tub. See section Cleaning andDisinfection Instructions.
6 Model A (without MultiClean): 20 minutes after the tub is
emptied, the air-blower activates for 1 minute.
Model B: The button ON/OFF has to be pushed to start the
blower, which then will activate for 1 minute.
NOTE
Only use emulsifying mineral oil.Operating the air blower with soapy water in the tubis not recommended, as foaming of the bath water islikely to occur. Use clean water whenever possible.
NOTEThe blower cannot be stopped during the 1-minute
dry cycle, but the speed can be controlled duringthis time.
If the bather has both of their feet in contact with bothof the water sensors at the same time, the seal maynot deflate.
5/18/2018 Arjo Freedom Bath Manual
21/48
21
Waste Water Pan
The drain pan is placed on the right hand side of the Freedom
Bath.
Placed in position shown in figure below it will collect spilt /waste water.
Placed in position upside down as shown in figure below it will
lead spilt water from Freedom Bathonto the floor.
NOTE
The water in the drain pan may be contaminated.Use caution when emptying.
5/18/2018 Arjo Freedom Bath Manual
22/48
22
Home Care Use
For Distr ibutors and RentersWhen transportingFreedom Bath to the customer
with a van:
Make sure the bathis properly secured duringtransport.
When delivering theFreedom Bath make sure
that:
The requirements according to the site preparation
instructions prior to installation are followed:
Material: The floor should be made of a
slip-resistant material, free of bumps.
Floor slope: When using a floor drain, the
slope towards the drain should not exceed 1:50.
Floor Attachments: The floor construction mustbe suitable for anchoring the bolts.
The bath is installed according to theAssembly
and Installation Instructionby qualified
personnel.
Make sure:
The thermostatic mixer has been calibrated
according to theAssembly and Installation
Instructionsby an ArjoHuntleigh service
technician.
You read thisIFUtogether with the receiver
(including relatives and caregivers).
Show the features and intended usage described in
theIFU with help of the real product.
Read all the warnings to the receiver.
The user has understood the cleaning and
disinfection instructions.
Perform a functionality test according to Care and
Preventive Maintenance in thisIFU.
The environment fulfils all the requirements
described in thisIFU.
WARNINGTo prevent scalding, make sure that thewater mixer has been calibrated. Confi rm
that responsible organization hasestablished calibration routines.
Using the Freedom BathBefore usingFreedom Bathin home environment
make sure that:
All caregivers, including relatives, have read andunderstood the instructions in thisIFU.
The space requirements for the bath are followed.
(See Fig. 1)
When theFreedom Bath is not in use make sure
that:
No children can access the bath.
No pets can come in contact with the bath.
The storage environment fulfils the requirements
specified under Technical Specificationsin this
IFU.
WARNINGTo avoid st rangulation, make sure to never
leave children unattended near theequipment.
5/18/2018 Arjo Freedom Bath Manual
23/48
23
Space requirements around the bath
Freedom Bathmust always be installed according to
recommended space requirements, this to provide optimal
working conditions for personnel and resident.
Available area for li ft integrationFreedom Bath in lift accessible version (LA) allows following area
for lift integration, limited by the drain connections.
NOTES
Fig. 1
5/18/2018 Arjo Freedom Bath Manual
24/48
24
Cleaning and Disinfection Instructions
DisinfectionThorough disinfection routines are necessary tostop the build-up of bacteria on and in theequipment.
This is particularly vital in cases where theFreedom Bathis a shared facility. Effectivedisinfection as outlined below reduces the riskof cross-infection between residents.
Only use ArjoHuntleigh branded disinfectantcleansers (e.g. Arjo Clean).
If you have any questions regarding disinfecting the
Freedom Bath, or wish to order disinfectant fluid,
contact ArjoHuntleigh Customer Service. See section,
Parts and Accessories.
Make sure to have the Material Safety Data Sheets
(MSDS) available for the disinfectant being used.
WARNING
To avoid eye and skin damage, always useprotective glasses and protective gloves.If contact occurs, rinse with plenty of water.If eyes or skin become irritated, consul t aphysician. Always read theInstructions forUse and Material Safety Data Sheet of thedisinfectant.
WARNINGTo prevent cross-contamination, alwaysfollow the disinfection instructions in thisInstructions for Use.
WARNINGTo avoid eye or skin irr itation, neverdisinfect in the presence of a resident.
Al lowed Disinfectants Arjo Clean
Arjo General Purpose Disinfectant
Arjo Disinfectant Cleanser IV
Arjo All Purpose Disinfectant
(not for MultiClean)
Arjo CenKleen IV
Accessories for Dis infecting theFreedom Bath
Protective gloves
Protective glasses
Spray bottle with cleaning fluid (detergent and
disinfectant) or disinfection spray handle with
cleaning fluid (detergent and disinfectant)
Spray bottle with water or shower handle with
water
Cloths - wet and dry
Disposable towels
Soft bristle brush
Long handled soft bristled brush
CAUTION
To avoid damage on the equipment only
use ArjoHuntleigh branded d isinfectants.
5/18/2018 Arjo Freedom Bath Manual
25/48
25
Always Follow these 25 Steps forProper Cleaning and Disinfection.
Removing v isual residue (Step 1-4 of 25)
1 Put on protective gloves and eye wear.
2 Open the drain to empty any left over water.
3 Detach and place the head cushion (if applicable)
and support strap on the bottom of the bathtub.
4 Shower and rinse the bath, head cushion and
support strap with water to remove visible
residue. Turn the head cushion and support strap
and rinse again.
Cleaning (Step 5-12 of 25)
5 Close the drain by raising the door to top position.
6 Spray disinfectanton all internal bath surfaces, the
head cushion and support strap at the bottom of the
tub. Turn the head cushion and support strapand
spray on the other side. Pay attention to parts, knobsand sensors attached to the bath surface such as
safety belt knobs and surface overflow outlet.
7 Scrub all the surfaces of bath, the head cushion and
support strapwith a soft bristle brush or cloth (to
remove any deposits e.g. skin flakes).
8 Open the drain by pressing the door seal/drain
button.
9 Use the shower handle and rinse all parts clean
with water (temperature approximately 25 C) to
remove the disinfectant.
10 Soak a cloth in disinfectant.
11 Wipe all other contact areas such as the outside of
the bath (particularly behind the head).
12 Wet a new cloth with water and remove all traces of
the disinfectant on contact areas.
Disinfection (Step 13-22 of 25)
13 Use a spray bottle and spray disinfectant in the
drain.
14 Close the drain.
15 Spray disinfectant on all internal bath surfaces, the
head cushion and support strap at the bottom of
the tub. Turn the head cushion and support strap
and spray on the other side. Pay attention to parts,knobs and sensors attached to the bath surface such
as safety belt knobs and surface overflow outlet.
16 Allow an appropriate contact time of the
disinfectant according to the instructions on the
disinfectant bottle.
17 Open the drain.
18 Rinse all parts clean with water (temperature
approximately 25 C). Use the shower handle to
remove cleaning fluid.
19 Soak a cloth in disinfectant.
20 Wipe all other contact areas such as the outside of
the bath (particularly behind the head).
21 Allow to stand for 10 minutes.
22 Wet a new cloth with water and remove all traces
of cleaning fluid on contact areas.
Drying (Step 23-25 of 25)
23 Dry each part of the Freedom bath with a clean
dry cloth.24 The door should be left in top position when the
tub is idle.
25 Leave to air dry.
5/18/2018 Arjo Freedom Bath Manual
26/48
26
Disinfecting the Air Spa UsingMultiClean (32 Steps)
Cleaning (Step 1-16 of 32)
1 Put on protective gloves and eye wear.
2 Check the level of the disinfectant in the
MultiClean.
3 Lift out the spray handle from theMultiClean
disinfection system and hold it over the bath tub.
4 Turn the ON/OFF control on theMultiClean to
the ON position. Turn the function selection
control to the disinfection setting (yellow).
5 Place the disinfection spray handle into the
disinfectant/rinsing ferrule and turn either way to
secure it (some force may be needed).
6 Press the trigger handle and hold it until the
disinfectant agent flows from allAir Spanozzles.
7 Let it run for 10 seconds.
8 Remove the disinfection spray handle from the
disinfectant/rinsing inlet.
9 Turn theMultiCleancontrol to the OFF position.
10 Place the disinfection spray handle in its holder.
11 Place the water spray handle into the disinfectant/
rinsing inlet and turn either way to secure it (some
force may be needed).
12 Press the trigger handle and hold it until clean
water flows from all nozzles.13 Let it run for another 30 seconds.
14 Remove the shower handle from the disinfectant/
rinsing inlet.
15 Rinse the bath.
16 Place the spray handle back into the holder on the
MultiCleanand turn the unit off.
Disinfection (Step 17-31 of 32)
17 Lift out the spray handle from theMultiClean
disinfection system and hold it over the bath tub.
18 Turn the ON/OFF control on theMultiClean to the
ON position. Turn the function selection control
to the disinfection setting (yellow).
19 Place the disinfection spray handle into the
disinfectant/rinsing inlet and turn either way tosecure it (some force may be needed).
20 Press the trigger handle and hold it until the
disinfectant agent flows from allAir Spanozzles.
21 Let it run for 10 seconds.
22 Remove the disinfection spray handle from the
disinfectant/rinsing inlet.
23 Turn theMultiCleancontrol to the OFF position.
24 Place the disinfection spray handle in its holder.
25 Allow an appropriate contact time of the
disinfectant according to the instructions on the
disinfectant bottle.
26 Place the water spray handle into the disinfectant/
rinsing inlet and turn either way to secure it (someforce may be needed).
27 Press the trigger handle and hold it until clean
water flows from all nozzles.
28 Let it run for another 30 seconds.
29 Remove the shower handle from the disinfectant/
rinsing inlet.
30 Rinse the bath.
31 Place the spray handle back into the holder on the
MultiCleanand turn the unit off.
Drying (Step 32 of 32)
32 Press the button ON/OFF to start the air-blower,
which then will be activated for 1 minute.
NOTE
Disinfection should be distributed throughallAir Spanozzles, or proper disinfectioncan not be guaranteed. Contact an Arjo-
Huntleigh technician if that problem occurs.
NOTEThe blower cannot be stopped during the1-minute dry cycle, but the speed can becontrolled during this time. If the bather hasboth of their feet in contact with both of the
water sensors at the same time, the seal maynot deflate.
5/18/2018 Arjo Freedom Bath Manual
27/48
27
Microbiological Formation PreventionIn order to enhance the on-site curative actions (chlorine or
thermal shock), which do not guarantee a reduction of the
contamination long term, make sure to follow the instructions
below.
Do not forget to contact ArjoHuntleigh for the annual Preventive
Maintenance visit.
Installation precautions
In order to limit the growth of bacterial flora, it is necessary
to take action at four levels: Avoid stagnating water and make sure proper water
circulation;
Take precautions against the formation of scale andcorrosion based on the water quality;
Maintain a high water temperature all the way fromthe hot water dispenser to the different distributionpipes;
Mix hot and cold water as close as possible to thepoint of use.
Use
Make sure that the water circulates in the bath andthe shower on a daily basis even if the bath tub is notused; and particular to make sure to remove anywater that may be left behind in the hose.
Let the water flow approximately 5 minutes before the
first bath of the day. Clean and disinfect the bath tub according to the IFU
before the first bath of the day and after the bath ofeach resident.
5/18/2018 Arjo Freedom Bath Manual
28/48
28
Care and Preventive Maintenance
The Freedom Bathis subject to wear and tear, and the following actions must be performed when specified to
make sure that the product remains within its original manufacturing specification.
Preventive Maintenance Schedule: Freedom
WARNINGTo avoid malfunction resulting in injury, make sure to conduct regular inspections and followthe recommended maintenance schedule. In some cases due to heavy use of the product andexposure to aggressive environment more frequent inspections should be carried out. Localregulations and standards may be more stringent than the recommended maintenanceschedule.
CAREGIVER OBLIGATIONS Action/Check Every DAY Every
WEEK
Every
MONTH
Every 2:nd
YEARDisinfect X
Visually check all exposed parts X
Check door seal X
Visually check hoses, pipes and connections X
Perform functionality test X
Empty and clean pan under tub X
Visually check the support strap, if any X
Exercise the thermostat mixer XCheck/clean filters, incoming water X
Replace the safety strap X
WARNINGTo avoid injury to both resident and caregiver, never modify the equipment or useincompatible parts.
5/18/2018 Arjo Freedom Bath Manual
29/48
29
Caregiver ObligationsCaregiver obligations shall be carried out by personnel withsufficient Freedom Bathknowledge following the instructionsin thisIFU.
Daily
Disinfect. Freedom Bathhas to be cleaned immediately
after use. Standard disinfection agents and shampoos should
be used in recommended concentrations. Clean door strip/seal and under the tub:
Instruction for non lift accessible version of Freedom Bathonly: To make area at lower part of the door and under tubaccessible for cleaning, perform following procedure:(See Fig. 1-2)
1 Hold the door up and door down buttons pressed
simultaneously for 30 seconds, until the temperature display
starts flashing.
2 Press the door down button. The door will move under
the tub, leaving the lower part of the strip/seal and the area
under the tub free for cleaning. Take caution at this
operation as the crush protection is off. The protection is
automatically activated again after one minute.
Weekly Visually check all exposed parts.Make sure no cracks or
sharp edges could cause the resident or caregiver injury.
Check door seal:Check the seal for cracks or other
damage. Check along the complete length that it is not
twisted, shown as (B) in the illustration. Correct placementis shown as (A). (See Fig. 3)
WARNINGTo avoid injury, only use the emergencylowering when normal lowering is impossible.Use extreme care during lowering.
CAUTION
To avoid damage on the equipment on ly useAr joHuntleigh branded dis in fectants.
Fig. 1
Fig. 2
Fig. 3
A B
5/18/2018 Arjo Freedom Bath Manual
30/48
30
Visually check hoses, pipes and connections:
Remove the left and right cover by removing the screws and
lifting the covers upwards. Visually inspect for leaks of any
kind on hoses, pipes, connection and drain. (See Fig. 4)
Perform functionality test:Test all panel functions and
disinfection options. With water on: check shower hose and
shower handle for damage - replace if defect. Empty and clean accumulated water and dirt from the
drain pan under the tub:
Clean the suction filter from dirt and/or lime build up on the
surface of the net.
Visually check the support strap.Check the complete
length for fraying, cuts, crack, tears, that no inner fabric is
showing and that no other damage is visible. If the strap is
found damaged, replace it.
Monthly Check/clean filters incoming water (with mixer):
A rinsing valve with a filter is mounted on each of the
two water supply hoses found under the left front cover.
The filter should be rinsed in both valves as follows:
1 Remove the left cover by removing the screws and lifting it
upwards. (See Fig. 4)
2 Close the valves. The handles (red for hot water and blue for
cold) should be in a cross position
(See Fig. 5).
3 Remove the cap (A)with a wrench. (See Fig. 5)
4 Pull out the filter (B)and clean it carefully in water.
(See Fig. 5)5 Reassemble the filter.
6 Fit the cap.
Exercise the thermostat mixer:
Turn the temperature control knob back and forth over the
whole temperature range. This is particularly important in
areas with hard water. (See Fig. 6)
Yearly
Freedom Bath must be serviced according to thePreventive Maintenance Schedule (Qualified Personnel Action/
Check).
WARNINGPressurised system and risk of scalding. Makesure that the valve (A) is closed before removingthe cap, this is especially important for the hotwater valve.
Fig. 4
Fig. 5
B
A
Fig. 6
5/18/2018 Arjo Freedom Bath Manual
31/48
31
WARNINGTo avoid injury and/or unsafe product, the maintenance activities must be carried out at thecorrect frequency by qualified personnel using correct tools, parts and knowledge ofprocedure. Qualified personnel must have documented training in maintenance of this device.
QUALIFIED PERSONNEL Action/Check EveryYEAR
Every3:rd
YEAR
Every5:th
YEAR
Check/adjust mixer including seal kit/complete thermostatic unit X
Check/clean filters, incoming water X
Check valves and membranes replace if necessary X
Check/replace seal kit or complete shower handle X
Lubricate moving parts XCheck the emergency seal release valve X
Check hoses and connections for leaks and damage X
Check all vital parts for corrosion and damage X
Perform full feature functionality test X
Check mechanical attachments X
Check that latest updates have been implemented X
Check the earth wiring connections X
Check door protection (only lift accessible) X
Check door system X
Replace filter, air-blower (Air spa) X
Replace air jet diaphragm (Air spa with MultiClean) X
Replace all pressurized hoses X
NOTE
Optimum performance and safety in operation are made sure by careful daily use of the equipmentaccording to the instructions. Early identification of any damage by routine weekly checks, andannual maintenance. Following these procedures correctly will also help to maximize the FreedomBaths service lifetime.
5/18/2018 Arjo Freedom Bath Manual
32/48
32
Troubleshooting
NOTE
If the product does not work as intended, immediately contact your local ArjoHuntleigh representative
for support.
PROBLEM (using the Freedom Bath) ACTION
In the event of power failure during bath.
1 The tub drain is opened automatically.
2 The door can be manually pushed down by pushing the
emergency button.
Nothing happens when pressing a button on thepanel. Function lock is activated Red LED forfunction lock is on.
Release the function lock by pressing the 2 buttons DOOR
UP and DOOR DOWN at the same time for 1 second.
It is not possible to stop a function by pressing abutton.
Wait for one minute. The Air Spa is in the dry cycle(option).
Air Spa stops during operation (option).
1 Normal, if used more than 15 minutes.
2 If used less than 15 minutes it may be overheated due to
high ambient temperature or clogged filter. Can be
started when cooled off.
3 Power failure.
Water from shower and filling spout is slow.
1 In order to feel if any hot water is coming in feel theincoming hot water line to see if hot.
2 Check and clean filter for incoming water according to
section Care and Preventive Maintenance.
Auto fill function will not stop filling afterreaching high water level sensor.
Metal sensor plugs need cleaning because of collected buildup. See section Cleaning and Disinfection Instructions.
5/18/2018 Arjo Freedom Bath Manual
33/48
33
Intentionally left blank
5/18/2018 Arjo Freedom Bath Manual
34/48
34
Technical Specifications
General
Dimensions exterior 1510 x 760 x 1045 mm (59 1/2 x 29 3/4 x 41 1/8)
Dimensions seat 480 x 480 mm (18 7/8 x 18 7/8)
Colour White
Weight - still bath 130 kg (286 Ibs)
Weight with air spa 140 kg (308 Ibs)
Tub volume (with resident) approx. 320 litres
Drain flow rate 130 l/min
Drain flow rate with water trap 110 l/min
Sound level 66 - 79,5dBA
Max. ambient temperature 40 C (104 F)Pollution degree 2
SWL (Safe Working Load) (resident + water) 550 kg (1212 lbs)
Max. patient weight 160 kg (353 lbs)
Range of thermometer display 10-50 C (50-122 F)
Accuracy of thermometer display +/-1 C (1,8 F)
Precision of displayed value 1 C (1,8 F)
Max. floor load 675kg / 0,6 m2
Max. floor pressure 0,6 N/mm2
Degree of protection IPX4IP: Ingress ProtectionX: The protection against contact and ingress ofobjects is not specified for this product.4: Water splashing against the product from anydirection does not effect safety or essentialperformance
Operating Conditions
Temperature 10C (50F) to 40C (104F)
Humidity (Relative) Max 90% at 20C (68F)
Atmosperic pressure range 700-1060 hPa
Transport and Storage Conditions
Temperature -20C (-4F) to 70C (158 F)
Humidity (Relative) 80% at 20C (68F)
Atmosperic pressure 500-1100 hPa
5/18/2018 Arjo Freedom Bath Manual
35/48
35
NOTE
All drainage, water and electrical installation work should be carried out by qualified personnel, inaccordance with local and national regulations.
Electric Supply
Voltage230/240 V, single phase120 V (US)
Frequency 50 Hz
Fuse T 6.3 AL
Ground Fault Circuit Interrupter(not included in delivery) 10 mA
The unit must be continuously powered and connected via a ground fault circuit interrupter.
The unit must be connected to protective earth (PE).
Power supply cord Replaced by qualified personnel
Water Supply
Cold/warm water connections, inlets and outlets 3/4
CW temperature 2-20 C (36-68 F)
WW temperature 60-80 C (140-176 F)
Drainage
Tub drain 1 1/2
Floor drain recommended to accommodate emergency user evacuation.
WARNINGTo avoid electric shock, make sure that the equipment is connected to: Continuously powered supply mains with protective earth. Separate fuse and ground fault circuit interrupter (GFCI) A mains disconnection device Equipotential bonding point
Al l instal lat ions must be in accordance with local codes and regulations.
Mains Disconnection Device
Permanently installed in wall. Visible and accessible at all times
Mains transient voltage 4kV*
Creepage distance 3 mm*
Air clearance 1,8 mm*
Direction of movement Up and down, right and left,clockwise and counterclockwise
* If local regulations are higher, they must be met.
5/18/2018 Arjo Freedom Bath Manual
36/48
36
Allowed Product CompatibilityFreedom Bath integrates with the followingArjoHuntleigh products:
Stedy, Sara Stedy, Sara Light, Sara Plus, Sara 3000and MultiClean
No other combinations are allowed
RecyclingThe device should be recycled according to national regulations
Package Wood, corrugated cardboard and plastic arerecyclable
The bath Electric, steel and plastic parts shall be separated andrecycled according to WEEE.
Disposal of the Freedom Bath
Bathtub The device is marked with the WEEE symbol to indi-cate that it is electronic equipment covered by theDirective 2002/96/EC on waste electrical and elec-tronic equipment. In European countries the crossedout wheeled-bin WEEE symbol reminds you that allthe electrical and electronic products, batteries andaccumulators must be taken to separate collection atend of their working life. This requirement applies inthe European Union. Do not dispose these productsas unsorted municipal waste. You can return yourdevice and accessories to ArjoHuntleigh or you cancontact your local authorities for advice on disposal.
5/18/2018 Arjo Freedom Bath Manual
37/48
37
Intentionally left blank
5/18/2018 Arjo Freedom Bath Manual
38/48
38
Labels on the Freedom Bath
On the labels you will find the following
information:
Plumbing Approval
Supply voltage 230-240 V~50Hz (EU)
120 V~60Hz (US)VA Max power
IPX 4 Protection class against splashingwater
Class I Connected to protective earth
Type B, Applied part:protection against electrical shockin accordance with EN/IEC60601-1.
Read theIFUbefore use
Separate electrical and electroniccomponents for recycling inaccordance with the EuropeanDirective 2002/96/EG (WEEE)
ANSI Z124.1.2-2005
Plastic Bathtub and Shower Units
ANSI/ASMEA112.19.7M-1995
Whirlpool Bathtub Appliances
ANSI/ASMEA112.19.8-1987
Suction Fittings
ANSI/ASSE1001-1988
Pipe Applied Vacuum Breakers
ANSI/ASSE1014-1989 Hand- Held Showers
ANSI/ASSE1016-1996
Individual Thermostatic, Pres-sure Balancing and CombinationPressure Balancing and Thermo-static Control Valves for Individ-ual Fixtures
CAN/CSAC22.2
No.601.1-M90
Medical Equipment with respectto electrical shock,fire and mechanical hazards onlyin accordance with Standards no.UL60601-1
CAN/CSA-B45.0-2004 andB45.5-2004
Patient bathing units
CE marking (EU-models 230/240V - 50 Hz)
WRAS (GB only)
WRAS approved Thermostatic Mixing Valves,
according to National Health Service.
Model Engineering Specification D 08- TMV3.
Thermostatic Mixing Valves (Health care Premises).
Designation Code: HP-S / HP-T44.
Warning labelsStates the actual warnings and cautions for the
product.
Identif ication labelThe identification label states the type of equipment
and serial number (see figure).
Water connection labelRequired max. and min. temperature for cold and hot
water and max./min. water pressure.
Attention labelAttention label placed on the button for activation of
the emergency seal release valve.
CAN/CSA-B64.0-1994 andB64.1.1-1994
Plumbing Fixtures, BackflowPreventers and Vacuum Breakers
CE marking in accordance with theMedical Devices Directive 93/42/EEC.
The equipment has been EMC-testedand fulfils all requirements accordingto IEC 60601-1-2. Electric safetyaccording to EN/IEC 60601-1. Referto Notified Body: BSI.
UL marking (US-models 120V-60Hz)Medical Equipment with respect toelectrical shock, fire and mechanical
hazards only in accordance withStandards no. UL 60601-1 CAN/CSA-C22.2 No.601.1-M90
4ML5 Certificate control number for UL
CLA
SSIFIED
S
5/18/2018 Arjo Freedom Bath Manual
39/48
39
WARNING
Disconnect electrical
power before servicing
WARNINGRisk of fire -replace fuse as marked
CAUTION
To reduce risk of electricalshock do not remove the lid.Refer to qualified
service personnel
COLD HOTFROIDE CHAUDEKALT WARM
MIN 300 kPa (44 psi)
MAX 600 kPa (87 psi)MIN 200 kPa (29 psi)
MAX 600 kPa (87 psi)
MAX 25C (77F)MIN 38C (100F)
MAX 80C (175F)
8418363
ArjoHuntleigh ABVerkstadsvgen 5241 38 Eslv, SWEDENMade in Sweden
Read the operating instructions before useMerci de prendre connaissance de la notice d'utilisationLesen Sie bitte die bedienungs-anleitung durch
MODEL: AFXXXXX-XXFreedom Bath
8418539E
120 V ~60HzMax 1100 VAIPX 4
Class I
Mode of operation:Air spa:
ED max 50%15 min on / 15 min off
Door opening:ED max 10%
SWL Safe Working Load
550 kg / 1213 lbsMax Total Load550 kg/ 1213 lbs
Max Patient Weight
160 kg / 350 lbs
8418675D
CAN/CSA - C22.2 No. 601.1-M90
UL60601-1and
4ML5
MEDICAL EQUIPMENT
PATIENT BATHING UNIT
IN ACCORDANCE WITH
ANSI Z124.1-1995
ANSI/ASME A112.19.7M-1995
ANSI/ASME A112.19.8M-1987
ANSI/ASSE 1014-1989
ANSI/ASSE 1016-1996
CAN/CSA B45.5 and B45.5-02
CAN/CSA B64.0 and B64.1.1-01
CAN/CSA B64.0 and B64.8-01
Example of
Water connection label
Warning label
Data label EU
Approval label
Address label
Bonding lug
Connect incoming electrical service
See installation manual for instructions
8418372
Warning label
Field wiring box
SEE0102001
Example ofidentification label
Manufacturing Year Week
Serialnumber
countrySE=Sweden
Manufacturing
worksE=Eslv
Product no
Serial no
AFA XXXX
SEE0102001
Made by Arjo in Eslov, Sweden
010115
ArjoHuntleigh ABVerkstadsvgen 5241 38 Eslv, SWEDENMade in Sweden
Read the operating instructions before useMerci de prendre connaissance de la notice d'utilisationLesen Sie bitte die bedienungs-anleitung durch
MODEL: AFXXXXX-XXFreedom Bath
8418538D
230-240 V ~50HzMax 1100 VAIPX 4
Class I
Mode of operation:Air spa:
ED max 50%15 min on / 15 min off
Door opening:ED max 10%
SWL Safe Working Load
550 kg / 1213 lbsMax Total Load550 kg/ 1213 lbs
Max Patient Weight160 kg / 350 lbs
Data label US
Calibration label located
on control panel before
irst use
Applied Part
Attention label
WARNING!
Do not use before calibration.
FR
AVERTISSEMENT!Ne pas utiliser avant calibration.
DEWARNUNG!Vor der Kalibrierung nicht benutzen.
NL
WAARSCHUWING!Niet gebruiken vr kalibreren.
ITAVVERTENZA!Non utilizzare prima della taratura.
ESADVERTENCIA!No utilizar antes de la calibracin.
PL
UWAGA!Nie uywa przed przeprowadzeniem kalibracji.
8418722A
5/18/2018 Arjo Freedom Bath Manual
40/48
40
Approvals and List of Standards
CERTIFICATE STANDARDS
EN/ISO/IEC/UL 60601-1 Medical electrical equipment
Part 1: General requirements for basic safety and essentialperformance.
EN 60601-1-2 Electromagnetic Compatibility -Requirements and Tests
EN 60601-1-11 Requirements for medicial electrical equipment and medicalelectrical systems used in the home healthcare environment.
CAN/CSA-C22.2 No. 601.1 Medical equipment Certified for Canada
ANSI Z124. 1-1995 Standards for Plastic Bath Tub Units
ANSI/ASSE 1014-1989 Handheld Shower ANSI/ASSE 1016-2005 Individual Thermostatic, Pressure Balancing and Combination
Pressure Balancing and Thermostatic Control Valves forIndividual Fixtures.
5/18/2018 Arjo Freedom Bath Manual
41/48
41
Intentionally left blank
5/18/2018 Arjo Freedom Bath Manual
42/48
42
Electromagnetic Compatibili ty
Medical electrical equipment needs special precautions regarding EMC (Electromagnetic compatibility) and
needs to be used according to the EMC information below.
Portable and mobile RF communications equipment can affect Freedom Bath.
WARNINGStacking or placing other electrical equipment next to this device is not recommended, it caninterfere with the equipments operation and safety. Portable and mobile radio-frequency (RF)communications equipment can interfere with th is equipment operation and safety.
WARNING
The equipment may cause radio interference or may disrupt the operation of nearbyequipment.It may be necessary to take action, such as reorienting, relocating the equipment or shieldingthe location.
Guidance and manufacturers declaration electromagnetic emissions
The Freedom Bathis intended for use in the electromagnetic environment specified below. The customer or
the user of the Freedom Bathshould assure that it is used in such an environment.
Emissions test Compliance Electromagnetic environment guidance
RF emissions
CISPR 11
Group 1 Freedom Bathuses RF energy only for its internal
function. Therefore, its RF emissions are very low and
are not likely to cause any interference in nearby
electronic equipment.
RF emissions
CISPR 11
Class B Freedom Bathis suitable for use in all establishments,
including domestic establishments and those directly
connected to the public low-voltage power supplynetwork that supplies buildings used for domestic
purposes.Harmonic emission
IEC 61000-3-2
Class A
Voltage fluctuations/flicker
emission
IEC 61000-3-3
Complies
5/18/2018 Arjo Freedom Bath Manual
43/48
43
Lift-functions, tilt-functions and temperature measurement were determined to be Essential Performance.
Guidance and manufacturers declaration electromagnetic immunity
The Freedom Bath is intended for use in the electromagnetic environment specified below. The customer or
the user of the Freedom Bathshould assure that it is used in such an environment.
Immunity test IEC 60601test level
Compliance level Electromagneticenvironment guidance
Electrostatic
discharge (ESD)
IEC 61000-4-2
6 kV contact 8 kV air
6 kV contact 8 kV air
Floors should be wood, concrete or
ceramic tile. If floors are covered
with synthetic material, the relative
humidity should be at least 30%.
Electrical fast
transient/burs
IEC 61000-4-4
2 kV for power
supply lines
1 kV forinput/output lines
2 kV for power
supply lines
input/output lines not
applicable
Mains power quality should be that
of a typical commercialor hospital environment.
Surge
IEC 61000-4-5
1 kV line(s) to line(s)
2 kV line(s) to earth
1 kV line(s) to line(s)
2 kV line(s) to earth
Mains power quality should be that
of a typical commercialor hospital environment.
Voltage dips,
short
interruptions
and
voltage
variationson power supply
input lines
IEC 61000-4-11
95% dip in UT)
for 0,5 cycle
40% UT
(60% dip in UT)
for 5 cycles
70% UT
(30% dip in UT)
for 25 cycles
95% dip in UT)
for 5 s
95% dip in UT)for 0,5
cycle
40% UT
(60% dip in UT) for 5
cycles
70% UT
(30% dip in UT) for 25
cycles
95% dip in UT) for 5s
Mains power quality should be that
of a typical commercialor hospital environment.
Power
frequency
(50/60Hz)
Magnetic fieldIEC 61000-4-8
3 A/m 3 A/m
Power frequency magnetic fields
should be at levels
characteristic of a typical location
in a typical commercial or hospital
environment.
NOTE UTis the a.c. mains voltage prior to application of the test level
5/18/2018 Arjo Freedom Bath Manual
44/48
44
Guidance and manufacturers declaration electromagnetic immunity
Freedom Bathis intended for use in the electromagnetic environment specified below. The customeror the user of Freedom Bathshould assure that it is used in such an environment.
Immunity test IEC 60601test level
Compli-ance level Electromagnetic environment guidance
Conducted RFIEC 61000-4-6
Radiated RFIEC 61000-4-3
3 Vrms150 kHz to
80 MHz
3 V/m80 MHz to
2.5 GHz
10 Vrms
3 V/m
Portable and mobile RF communications equipment
should be used no closer to any part of Freedom Bath,
including cables, than the recommended separation
distance calculated from the equation applicable to the
frequency of the transmitter.
Recommended separation distanced=0,35P
d=1,2P 80 MHz to 800 MHz
d=2,3P 800 MHz to 2.5 GHz
Where P is the maximum output power rating of the
transmitters in watts (W) according to the transmitter
manufacturer and d is the recommended separation
distance in metres (m).
Field strengths from fixed RF transmitters, as determined
by an electromagnetic site survey, ashould be less than
the compliance level in each frequency range. b
Interference may occur in the vicinity of equipment
marked with the following symbol:
NOTE 1 At 80 MHz and 800 MHz, the higher frequency range applies.
NOTE 2 These guidelines may not apply in all situations. Electromagnetic propagation is affected by
absorption and reflection from structures, objects and people.
a Field strengths from fixed transmitters, such as base stations for radio (cellular/cordless) telephones and land
mobile radios, amateur radio, AM and FM radio broadcast and TV broadcast cannot be predicted theoretically
with accuracy. To assess the electromagnetic environment due to fixed RF transmitters, an electromagnetic
site survey should be considered. If the measured field strength in the location in which Freedom Bathis used
exceeds the applicable RF compliance level above, the Freedom Bathshould be observed to verify normal
operation. If abnormal performance is observed, additional measures may be necessary, such as re-orienting or
relocating the Freedom Bath.
b Over the frequency range 150 kHz to 80 MHz, field strengths should be less than 10 V/m.
5/18/2018 Arjo Freedom Bath Manual
45/48
45
Recommended separation distances between portable and mobile RF communicationsequipment and Freedom Bath
Freedom Bathis intended for use in an electromagnetic environment in which radiated RF disturbances are
controlled. The customer or the user of Freedom Bathcan help prevent electromagnetic interference by
maintaining a minimum distance between portable and mobile RF communications equipment (transmitters)
and theFreedom Bathas recommended below, according to the maximum output power of thecommunications equipment
0,01
0,1
1
10
100
0,04
0,11
0,35
1,1
3,5
0,12
0,38
1,2
3,8
12
0,23
0,73
2,3
7,3
23
For transmitter rated at a maximum output power not listed above, the recommended separation distance d in
metres (m) can be estimated using the equation applicable to the frequency of the transmitter, where P is the
maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer.
NOTE 1 At 80 MHz and 800 MHz, the separation distance for the higher frequency range applies.
NOTE 2 These guidelines may not apply in all situations. Electromagnetic propagation is affected by
absorption and reflection from structures, objects and people.
5/18/2018 Arjo Freedom Bath Manual
46/48
46
Parts and Accessories
Support strapFor Disinfectant contactyour local representative
5/18/2018 Arjo Freedom Bath Manual
47/48
AUSTRALIAArjoHuntleigh Pty Ltd78, Forsyth streetOConnorAU-6163 Western AustraliaTel: +61 89337 4111Free: +1 800 072 040
Fax: + 61 89337 9077
BELGIQUE / BELGIArjoHuntleigh NV/SAEvenbroekveld 16B-9420 ERPE-MERETl/Tel: +32 (0) 53 60 73 80Fax: +32 (0) 53 60 73 81E-mail: info@arjohuntleigh.beCANADAArjoHuntleigh90 Matheson Boulevard WestSuite 300MISSISSAUGA, ON, L5R 3R3
Tel/Tl: +1 905 238 7880Free: +1 800 665 4831 InstitutionalFree: +1 800 868 0441 Home CareFax: +1 905 238 7881E-mail: info.canada@arjohuntleigh.com
ESK REPUBLIKAArjoHuntleigh s.r.o.Hlinky 118CZ- 603 00 BRNOTel: +420 549 254 252Fax: +420 541 213 550
DANMARKArjoHuntleigh A/S
Vassingerdvej 52DK-3540 LYNGETel: +45 49 13 84 86Fax: +45 49 13 84 87E-mail: info.dk@arjohuntleigh.com
DEUTSCHLANDArjoHuntleigh GmbHPeter-Sander-Strasse 10D-55252 MAINZ-KASTELTel: +49 (0) 6134 186 0Fax: +49 (0) 6134 186 160E-mail: info-de@arjohuntleigh.com
C. Psimitis Co LtdDimitriou Andr. 59GR-16121 KAISARIANI ATTIKIS: 21 0724 36 68: 21 0721 55 53
ESPAAArjoHuntleigh Ibrica S.L.Ctra. de Rub, 88 1 planta - A108173 Sant Cugat del VallsES- BARCELONA 08173Tel: +34 93 583 11 20Fax: +34 93 583 11 22E-mail: info.es@arjohuntleigh.com
FAR EASTARJO Far East LimitedUnit 3A, 4/F., block B Hoi Luen
Industrial Centre
55 Hoi Yuen Road,Kwun Tong, KowloonHONG KONG
Tel: +852 2508 9553Fax: +852 2508 1416
FRANCEArjoHuntleigh SAS2 Avenue Alcide de GasperiCS 7013359436 RONCQ CEDEXTl: +33 (0) 3 20 28 13 13Fax: +33 (0) 3 20 28 13 14E-mail : info.france@arjohuntleigh.com
INTERNATIONALArjoHuntleigh International Ltd.ArjoHuntleigh House
Houghton Hall ParkHoughton RegisUK-DUNSTABLE LU5 5XFTel: +44 (0) 1582 745 800Fax: +44 (0) 1582 745 866E-mail:international@ArjoHuntleigh.com
ITALIAArjoHuntleigh S.p.A.Via di Tor Vergata 43200133 ROMA - ITALIATel: +39 (0) 6 87426211Fax: +39 (0) 6 87426222E-mail: Italy.promo@arjohuntleigh.com
NEDERLANDArjoHuntleigh Nederland BVBiezenwei 214004 MB TIELPostbus 61164000 HC TIELTel: +31 (0) 344 64 08 00Fax: +31 (0) 344 64 08 85E-mail: info.nl@arjohuntleigh.com
NEW ZEALANDArjoHuntleigh Ltd41 Vestey DriveMount WellingtonAUCKLAND 1060Tel: +64 (0) 9 573 5344Free Call: 0800 000 151Fax: +64 (0) 9 573 5384E-mail: nz.info@ArjoHuntleigh.com
NORGEArjoHuntleigh Norway ASRyenstubben 2NO-0679 OSLOTel: +47 22 08 00 50Faks: +47 22 08 00 51E-mail: no.kundeservice@arjohuntleigh.com
POLSKAArjoHuntleigh Polska Sp. z o.o.ul. Ks Piotra Wawrzyniaka 2PL 62-052 KOMORNIKI (Poznan)Tel: +48 61 662 15 50Fax: +48 61 662 15 90E-mail: arjo@arjohuntleigh.com
PORTUGALArjoHuntleigh em Portugal:MAQUET Portugal, Lda. (Distribudor Exclusivo)Rua Poeta Bocage n. 2 - 2G1600-233 Lisboa, PortugalTel: +351 214 189 815Fax: +351 214 177 413E-mail: Portugal@arjohuntleigh.com
SUISSE / SCHWEIZArjoHuntleigh AGFabrikstrasse 8Postfach4614 Hgendorf,
Tl/Tel: +41 (0) 61 337 97 77Fax: +41 (0) 61 311 97 42
SUOMIArjoHuntleigh OYVanha Porvoontie 229FI-01380 VANTAAPuh: +358 9 4730 4320Faksi: +358 9 4730 4999
SVERIGEARJO Scandinavia ABVerkstadsvgen 5Box 61
SE-241 21 ESLVTel: +46 (0) 10-335 45 00Fax: +46 (0) 413-138 76E-mail: kundservice@arjohuntleigh.com
UNITED KINGDOMArjoHuntleigh UKArjoHuntleigh HouseHoughton Hall ParkHoughton RegisUK-DUNSTABLE LU5 5XFTel: +44 (0) 1582 745 700Fax: +44 (0) 1582 745 745E-mail:sales.admin@ArjoHuntleigh.com
USAArjoHuntleigh Inc.2349 W Lake Street Suite 250Addison, IL 60101Tel: +1 630 307 2756Free: +1 800 323 1245 InstitutionalFree: +1 800 868 0441 Home CareFax: +1 630 307 6195E-mail: us.info@ArjoHuntleigh.com
STERREICHArjoHuntleigh GmbHDrrstrasse 85
AT-6020 INNSBRUCKTel: +43 (0) 512 204 160 0Fax: +43 (0) 512 204 160 75
47
www.arjohuntleigh.com
ArjoHuntleigh Addresses
5/18/2018 Arjo Freedom Bath Manual
48/48
GETINGE GROUPis a leading global provider of products and systems that
contribute to quality enhancement and cost efficiency within healthcare and life
sciences. We operate under the three brands ofArjoHuntleigh, GETINGE and
MAQUET.ArjoHuntleighfocuses on patient mobility and wound management
solutions. GETINGE provides solutions for infection control within healthcare and
contamination prevention within life sciences. MAQUET specializes in solutions,
therapies and products for surgical interventions and intensive care.
www.ArjoHuntleigh.com
ArjoHuntleigh AB
Verkstadsvgen 5
241 38 EslvSWEDEN
Recommended