ADVANCED WARNINGSYSTEMS

XP95 MANUAL CALL POINT 55100-905AMPA FireFinder™ compatible product PDS213-0050

Product Data Sheet

Features: Resettable manual call point

No glass to replace after operation

Test is by actual operation

Fast and easy installation with new ‘plug and play’ terminals

S ingle key to reset the device imple maintenance using a sand remove the fron

The XP95 Manual Call Point

t cover

Anti-tamper facility

Modern aesthetically pleasing design

The XP95 Addressable Manual Call Point (MCP) is a ‘type A’ single action, red call point. It is supplied with a standard back box for surface mount installation and is suitable for indoor use only. For flush mounting, a suitable single-gang mounting box (min 20mm depth) is required.

Description

The device is put into alarm by pressing the resettable element. A fluorescent yellow marking appears indicating that the MCP is in alarm. The alarm is transmitted via the Apollo loop to the FireFinder™ Fire Alarm Control Panel. An LED on the front illuminates when the FireFinder™ receives this alarm signal.

The XP95 MCP can be tested periodically by actual operation and reset using a test key supplied with each device. The same key is used to remove the front cover.

With the use of the resettable element there is no frangible glass to replace and resetting the device can be quickly achieved. The user must set the address for each device to ensure correct operation. No two devices can share the same address setting on the same Apollo loop. This address setting must match the configuration that has been programmed into the FireFinder™ FACP. Terminations for the XP95 MCP are clearly marked for asy installation. e

When activated, the XP95 Manual Call Point not only interrupts the polling cycle to indicate to the FACP that it has been operated, but also reports its address. Thus an alarm and its location can be reported in less than 0.2 seconds.

Loop in / loop out terminations at the XP95 Manual Call Point, make installation easy. Field wiring may be terminated to a removal plug. Links supplied with the device allows for pre-commissioning without having to install the MCP.

Item Number Description

213-0050 Manual Call Point

213-0064 Hinged cover

L+ L+ L- L-FunctionalEarth

Insert as Shown toRemove Front Cover

ContinuityLinks

GreenYellow

O N

1 2 3 4 5 6 7

0

1

ExampleAddress Setto 78

DO NOT REMOVE LABEL

Manual Call Point

Item Number: 213-0050Part No: 55100-905 AMP051104 / 2CEN54-11 (Type A)

For indoor use onlyRefer to Installation Guide MAN15110832-CPD-XXXXManufactured for Ampac by Apollo Fire Detectors Ltd

0832 010n/02

N1236

+ + - -Functional Earth / Screen

ADDRESS

01 1 2 4 8 16 32 64

LPCB

Technical

Specifications

Power supply Loop powered 17 to 28 VDC Surge Current 750 μA @ 24 VDC (2sec typical) Quiescent Current 1mA @ 24 VDC Alarm Current 4mA @ 24 VDC Compatibility FireFinder™ Apollo Loop protocol Cabling 2 core - max. size 2.5mm2

Address setting 126 Size Call Point 89H x 88W x 26.5D mm

Back box 87H x 87W x 32D mm Colour RED Approvals EN54-11

Item Numbers

PDS213-0050-2 XP95 MCP.doc Page 1