ALLEGATO 5 PD.020
1/2
Noi : AMISCO Srl We : Via Piaggio, 70 I-20037 Paderno Dugnano
MI - ITALY
dichiariamo sotto la nostra responsabilità che il prodotto: declare under our sole responsability that the product: DC solenoids
Coil Code
Vn [ V ]
f [ Hz ]
I [ A ]
P [ W ]
Temperature Class
3009MD006W3 6 - 0.510 3 T5 3009MD012W3 12 - 0.250 3 T5 3009MD024W3 24 - 0.125 3 T5 3009MD048W3 48 - 0.063 3 T5 3009MD006W4 6 - 0.640 3.8 T4 3009MD012W4 12 - 0.320 3.8 T4 3009MD024W4 24 - 0.160 3.8 T4 3009MD048W4 48 - 0.080 3.8 T4 AC solenoids
Coil Code
Vn [ V ]
f [ Hz ]
I [ A ]
P [ VA ]
Temperature Class
3009MA012W2 12 50/60 0.2700 3.2 T5 3009MA024W2 24 50/60 0.1330 3.2 T5 3009MA048W2 48 50/60 0.0670 3.2 T5 3009MA100W2 100 50/60 0.0320 3.2 T5 3009MA110W2 110 50/60 0.0290 3.2 T5 3009MA115W2 115 50/60 0.0280 3.2 T5 3009MA120W2 120 50/60 0.0270 3.2 T5 3009MA220W2 220 50/60 0.0146 3.2 T5 3009MA230W2 230 50/60 0.0140 3.2 T5 3009MA240W2 240 50/60 0.0134 3.2 T5 (1) Vn = tensione nominale P = potenza nominale f = frequenza (1) Vn = nominal voltage P = nominal power f = frequency I = corrente nominale Tolleranza sui valori nominali di tensione: ± 10% I = nominal current Voltage Tolerance range on nominal values: ± 10% a cui si riferisce questa dichiarazione, è conforme a quanto richiesto dalla seguente Direttiva: to which this declaration relates, is in conformity with the provisions of the following directive:
ATEX 94/9/CE
DICHIARAZIONE CE DI CONFORMITA’ BOBINA EVI 30/9 EEx mb II 2G T4/T5
2D IP66 T135/T100 per l’uso in ambienti potenzialmente esplosivi
EC DECLARATION OF CONFORMITY COIL EVI 30/9 EEx mb II 2G T4/T5
2D IP66 T135/T100 to be used in potentially explosive atmosphere
ALLEGATO 5 PD.020
2/2
è fabbricato e collaudato secondo le Normative: with reference to the following standards:
IEC 60079-0 2004-01 IEC 60079-18 2004-03 EN 50281-1-1 1999-11 +A1 EN 50281-1-2 1999-09 +A1
______________________________________________________________________ ed è certificato presso il CESI come: certified by CESI: CESI 02 ATEX 142X ______________________________________________________________________ Organismo incaricato della Sorveglianza: Body responsible for supervision: CESI 0722 con Notifica CESI 03 ATEX 075Q
CESI 0722 with Notification CESI 03 ATEX 075Q _________________________________________________________________________
Paderno Dugnano, 30 Luglio 2004 CSQ Paderno Dugnano, July 30, 2004
Ing. Elio Mantovani Persona Autorizzata
Authorized Representative I dati riportati sui Cataloghi Amisco e tutte le misure The data supplied in AMISCO Catalogues are to be preventive necessarie al fine di evitare eventuali incidenti consulted, and pertinent accident prevention regulations devono essere osservate, durante l’installazione e l’utilizzo are to be followed during product installation and use. del prodotto. Questa dichiarazione perde la sua validità se Any unauthorized work performed by purchaser or by third il cliente o parti terze eseguono modifiche e/o riparazioni parties can impair its functions, and relieves AMISCO of all e/o fanno un uso improprio del prodotto. warranty claims and liability for any resulting damage.
-CESI
EXTENSION D.02/07to EC-Type Examination Certificate CESI 02 ATEX 142X
Equipment: Electrical Coils Type 3009M
Manufacturer: AMISCO S.r.l.
Address: via Piaggio 401-20037Paderno Dugnano (MI) - ITALIA
Admitted variationUpgrade to EN 60079-0 (2006), EN 60079-18'(2004), EN 61241-0 (2006), EN 61241-18 (2004) Standards.
j
Upgrade of nameplate.New thermal cutoff, Uchihashi ELCUT 12 seriesChange company name: from AMISCO S.r.l. to AMISCO S.p.a.
Equipment identification and descriptionThe electrical coils type 3009M for electrovalves are made of a induction coil that drive a pneumatic pilot in a two ormore way valve. The pilot and vaIves are not objet ofvaluations. The coils type 3009M have an internaInon resettingthermal-cutoff conform to EN 60691.
Protection modeAccording to the category, the type ofprotection mode and the temperature class, the equipment shall include thefollowing markings:
~ II 2GD Ex mb II T50rT4 Ex mbD 21 T95°C or T1300C
Ambient temperature: -15 + +50°C
This extension and annexed descriptive documents must be annexed to the EC-Type Examination CertificateCESI 02 ATEX 142X.
This document may only be reproduced in its entirety and without any change.
prepared
11.09.2007 - translation issued the Il th.09.2007
GuidoPrazzoli 1t~ob r.p~MirkoBalaz ~ ~
CESIS.p.A.Divisione Energia
"Area Tecnica Certificazione"Il Responsabile
Fiorenzo Bregani
page 1/2
date
verified
approved
CESICentro ElettrotecnicoSperimentale ItalianoGiacinto Motta SpA
Via R. Rubattino 5420134 Milano - ItaliaTelefono +39 022125.1Fax +39 0221255440www.cesLit
Capitale sociale 8 550 000 Eurointeramente versatoCodice fiscale e numeroiscrizione CCIAA 00793580150
Registro Imprese di MilanoSezione OrdinariaN. R.EA 429222P.I.IT00793580150
CESI
EXTENSION D. 02/07
to EC-Type Examination Certificate CESI 02 ATEX 142X
Report n. EX- A7023540
Descriptive documents (prot. EX- A723542)
Tecnicai note - rev.2EC Declaration of ConformityIstruzionsCheck list 01/07EX-2430A-TAMP - rev. 2EX-2430 - rev. 2EX-2469 - rev. 1EX-2475 - rev. 2EX-2475A - rev. 1EX-I957A-rev.IEX-247I-rev.2EX-243IA-rev.IEX-2036 - rev. 1EX-247IA-rev.2EX-1957 - rev. 2EX-1957C - rev. 1EX-2430A - rev. 2EX-2472 - rev. 1EX-2472 - rev. 1Notarization
pg.6pg.2pg.3pg.4
One copy of alI documents is kept in CESI files.
dateddateddateddateddateddateddateddateddateddateddateddateddateddateddateddateddateddateddateddated
25.05.2007.25.05.200725.05.200725.05.200725.05.200725.05.200725.05.200725.05.200725.05.200725.05.200725.05.200725.05.200725.05.200725.05.200725.05.200725.05.200725.05.200725.05.200725.05.200715.05.2006
Speciai conditions for safe use "X"The terminaI connection of permanently connected suppIy cabie shall be made in according to the types of protectionindicated in the EN 60079-0 and EN 61241-0 standard, and shall be in accordance with the installation rules specifiedfor the pIace where the apparatus is used.
Essentiai Health and Safety RequirementsThe Health and Safety Requirements are assured by compliance with the following Standards:EN 60079-0: 2006:
EN 60079-18: 2004:EIectricai apparatus for expIosive gas atmospheres -GeneraI requirements.EIectricai apparatus for expIosive gas atmospheres -Construction, test and marking oftype ofprotection encapsuiation "m" eIectricai apparatus.
EIectricai apparatus for use in the presence of combustibie dust -GeneraI requirements.EIectricai apparatus for use in the presence of combustibie dust -Protection by encapsuiation"mD".
EN 61241-0: 2006:
EN 61241-18: 2004:
This document may onIy be reproduced in its entirety and without any change..
Prot. A7023553 P: 2page 2/2
IN
STR
UC
TIO
NS
MA
NU
FAC
TUR
ER: N
AM
E:
AM
ISC
O s.
r.l.
A
DD
RES
S:
V
ia P
iagg
io, 7
0 –
Pade
rno
D. –
MI –
ITA
LY
TYPE
:
300
9M
N°
N.B
.:
0722
G
RO
UP:
II
CA
TEG
OR
Y:
2G e
2D
G
AS
AN
D C
OM
BUST
IBLE
DU
ST A
TMO
SPH
ERE
EQU
IPM
ENT
TYPE
OF
PRO
TEC
TIO
N:
e
ncap
sula
tion
“m”,
leve
l mb
C
ERTI
FIC
ATE
NU
MB
ER:
C
ESI 0
2 A
TEX
142
X
VO
LTA
GE
TOLE
RA
NC
E:
± ±±±1
0%
DU
TY C
YC
LE:
100%
ED
A
MB
IEN
T TE
MPE
RA
TUR
E:
-
15°C
÷ ÷÷÷ +
50°C
E
LEC
TRIC
AL
DA
TA:
DC
sole
noid
s C
oil
Cod
e V
n [ V
] f
[ Hz
] I
[ A ]
P [ A ]
Tem
pera
ture
C
lass
30
09M
D00
6W3
6 -
0.51
0 3
T5
100
°C
3009
MD
012W
3 12
-
0.25
0 3
T5
“ 30
09M
D02
4W3
24
- 0.
125
3 T5
“
3009
MD
048W
3 48
-
0.06
3 3
T5
“ 30
09M
D00
6W4
6 -
0.64
0 3.
8 T4
13
5 °C
30
09M
D01
2W4
12
- 0.
320
3.8
T4
“ 30
09M
D02
4W4
24
- 0.
160
3.8
T4
“ 30
09M
D04
8W4
48
- 0.
080
3.8
T4
“ A
C so
leno
ids
Coi
l C
ode
Vn
[ V ]
f [ H
z ]
I [ A
] P
[ VA
] Te
mpe
ratu
re
Cla
ss
3009
MA
012W
2 12
50
/60
0.27
00
3.2
T5
100
°C
3009
MA
024W
2 24
50
/60
0.13
30
3.2
T5
“ 30
09M
A04
8W2
48
50/6
0 0.
0670
3.
2 T5
“
3009
MA
100W
2 10
0 50
/60
0.03
20
3.2
T5
“ 30
09M
A11
0W2
110
50/6
0 0.
0290
3.
2 T5
“
3009
MA
115W
2 11
5 50
/60
0.02
80
3.2
T5
“ 30
09M
A12
0W2
120
50/6
0 0.
0270
3.
2 T5
“
3009
MA
220W
2 22
0 50
/60
0.01
46
3.2
T5
“ 30
09M
A23
0W2
230
50/6
0 0.
0140
3.
2 T5
“
3009
MA
240W
2 24
0 50
/60
0.01
34
3.2
T5
“
XX
XV
XX
TX
WW
/YY
The
coil
EVI3
0/9
EEx
mb
is d
evel
oped
to fi
t Am
isco
ope
rato
rs. I
f a d
iffer
ent o
pera
tor i
s us
ed, m
ake
sure
that
the
coil
pow
ered
with
nom
inal
vol
tage
doe
s no
t sho
w a
pow
er c
onsu
mpt
ion
exce
edin
g th
a va
lues
men
tione
d ab
ove.
In
any
cas
e, b
efor
e gi
ving
its
appr
oval
, Am
isco
has
to c
arry
out
con
sum
ptio
n an
d th
erm
ic te
sts
on y
he o
pera
tor
spec
imen
; on
the
cont
rary
thes
e te
sts
will
be
cond
ucte
d by
the
Clie
nt h
imse
lf w
ho h
as to
info
rm A
mis
co a
bout
the
resu
lts o
btai
ned.
In th
is c
ase
the
Clie
nt w
ill a
lso
be re
spon
sibl
e fo
r eve
ntua
l mal
func
tioni
ngs
incu
rred
by
usin
g no
n-te
sted
ope
rato
rs.
Wee
k an
d ye
ar o
f pro
duct
ion
of th
e co
mpl
ete
coil
are
prin
ted
on th
e up
per s
ide
of th
e so
leno
id, a
s sh
owed
in th
e ab
ove
draw
ing.
Th
e ou
tput
cab
le o
f the
sol
enoi
d co
nsis
ts o
f a b
row
n co
lore
d le
ad, o
f a b
lue
one
and
of a
yel
low
-gre
en o
ne.
The
brow
n an
d bl
ue le
ads
are
the
coil
pow
er s
uppl
y w
hile
the
yello
w-g
reen
one
, tha
t is
conn
ecte
d to
all
the
cond
uctiv
e ac
cess
ible
par
ts o
f the
coi
l, is
the
earth
con
nect
ing.
Th
e co
il ha
s al
so a
n ad
ditio
nal e
xter
nal c
onne
ctin
g un
it fo
r the
ear
th c
onne
ctio
n or
for t
he
equi
pote
ntia
l bon
ding
con
nect
ion.
W
arni
ng
“Ele
ttros
tatic
cha
rges
pro
duct
, cle
an o
nly
with
wet
clo
ths
or a
ntis
tatic
pro
duct
s.”
The
elec
trica
l co
nnec
tion
betw
een
sole
noid
and
ele
ctric
inst
alla
tion
has
to b
e pe
rfor
med
in c
ompl
ianc
e w
ith C
EI
EN 6
0079
-14
requ
irem
ents
.
Def
initi
ons a
nd S
ymbo
ls O
ur M
arki
ng
II
2G
EEx
m
b II
T5
or T
4
II
2D I
P66
T 1
00°C
or
T 13
5°C
W
here
:
:
Spec
ific
mar
king
of e
xplo
sion
pro
tect
ion
II
:
Gro
up II
- El
ectri
cal a
ppar
atus
for p
lace
s w
ith a
pot
entia
lly e
xplo
sive
atm
osph
ere,
ot
her t
han
min
es s
usce
ptib
le to
fire
dam
p.
2:
C
ateg
ory
2 - s
ee th
e bo
ard
belo
w.
G:
Exp
losi
ve g
as a
tmos
pher
es.
D
: Ex
plos
ive
atm
osph
ere
in th
e pr
esen
ce o
f com
bust
ible
dus
t. EE
x:
The
sym
bol E
Ex w
hich
indi
cate
s tha
t the
ele
ctric
al a
ppar
atus
cor
resp
onds
to o
ne o
f th
e pr
otec
tion
type
( EN
600
79 –
0 )
mb:
Type
of p
rote
ctio
n –
enca
psul
atio
n m
, lev
el m
b T4
/T5:
T
empe
ratu
re c
lass
for g
as
T135
/T10
0:
T
empe
ratu
re c
lass
for d
ust
IP66
:
The
degr
ees
of p
rote
ctio
n pr
ovid
ed b
y an
enc
losu
re a
gain
st,
ingr
ess
of s
olid
fore
ign
obje
cts,
dust
(firs
t num
ber)
and
wat
er (s
econ
d nu
mbe
r).
Zo
ne
Cat
egor
y D
escr
iptio
n 1
2 Eq
uipm
ent i
n th
is c
ateg
ory
is in
tend
ed fo
r use
in a
reas
in
w
itch
expl
osiv
e at
mos
pher
es
caus
ed
by
air/g
as
mix
ture
are
like
ly to
occ
ur.
21
22
Eq
uipm
ent i
n th
is c
ateg
ory
is in
tend
ed fo
r use
in a
reas
in
witc
h ex
plos
ive
atm
osph
eres
cau
sed
by a
ir/du
st
mis
ture
s a
re li
kely
to o
ccur
. Pa
dern
o D
ugna
no, J
uly
30, 2
004
Aut
hori
zed
Rep
rese
ntat
ive
Ing.
Elio
Man
tova
ni
CO
IL E
Ex m
Typ
e 30
09M
II NN
SS TTRR
UUCC
TTII OO
NNSS
This
docu
men
t can
not b
e m
odifi
ed w
ithou
t the
app
rova
l of t
he C
ertif
icat
ion
Inst
itute
Recommended