255//88”

77//88”

55//88”

33//88”

AIR

FLOW

177//88”

17/7/88”233//1166”

ABS POTTED BOXWITH FLANGE ANDMOUNTING HOLES

IONIZATIONBRUSH

LED

LEDIONIZATIONBRUSH

FLANGE

SIDE VIEW

TOP VIEW

111//44”155//88”

DIMENSIONSnot to scale

#12 SCREWOR SMALLER

AERISA 1214 W. BOSTON POST ROAD, SUITE 410, MAMARONECK, NY 10543 480-302-6300 877-4-AERISA info@aerisa.com www.aerisa.com

The Aerisa AerBRUSH is a needle point brush type ion-izer designed for almost any fan application includingRoof Top Units, Air Handling Units, FCUs, PTACs, HeatPumps, and even ductless split systems. It is designed tobe mounted at the fan inlet through which air is beingdrawn. The ionizer is self-contained in a potted ABS boxwith molded flange mounting holes. The AerBRUSH canbe powered with 12V DC, 24V AC, 120V AC and 230V ACwithout the use of an external power supply device ortransformer. The AerBRUSH is capable of treating 2,400CFM and is protected with a 500 mA glass cartridge fuse.

©2014 All righ

ts reserved

AerBRUSH - Submittal and IOM

Maximum Treated Airflow: . . . . . . . . . . . . . . . . .2,400 CFMPressure Drop: . . . . . . . . . . . . . . . . . . . . . . . . . . . . .NegligibleHousing Material: . . . . . . . . . . . . . . . . . . . . . . . . .ABS PlasticWeight: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 OuncesMaximum Operating Temperature: . . . . . . . .200�F (93�C)Electrical:Voltage Input: . . . . . . . . . . . . . . . . . . . . . . . . . .12V DC (-01)

. . . . . . . . . . . . . . . . . . . . . . . . . .24V AC (-02) . . . . . . . . . . . . . . . . . . . . . . . . .120V AC (-03) . . . . . . . . . . . . . . . . . . . . . . . . .230V AC (-04)

Power Consumption: . . . . . . . . . . . . . . . . . . . . . . . . .1 wattFrequency: . . . . . . . . . . . . . . . . . . . . . . . . . . . . .50/60 hertzOver Current Protection: . . . . . . . .500 mA In-Line Fuse

Mode of Operation:Needle Configuration: . . . . . . . . . . . . . . . . . . .Brush Type

How to Order:AerBRUSH-01

1 = 12V DC2 = 24V AC3 = 120V AC4 = 230V AC

Revision number

INSTALLATION INSTRUCTIONS

FANDISCHARGE

FAN INLET

IN LINE 500 mAGLASS CARTRIDGE FUSEPOWER WIRING

1.Mount the unit at the fan inlet using the holes in the mounting flange per the figure above, insuring the airstream blows over the 2 brushes simultaneously.

2. The unit should be mounted downstream of the filter.3. Connect the appropriate power per the following:

a. Red =Hot, Black =Neutral for 24V,120Vand 230VACpowerb. Red = Positive (+), Black = Negative (-) for 12V DC power

4. For 120V and 230V power input models, the installer shall provide a grounding method per the local AHJ.

5.When power is activated, the green LED light will illuminateindicating that the ionizer is functioning properly.

Recommended