Advanced Ingest and High Level Product Generation Systems• Critical DRO requirements that drive...

Preview:

Citation preview

Advanced Ingest and High Level Product Generation Systems

Outline

• Critical DRO requirements that drive ingest/processing technologies

• Critical technologies that have the most impact on satisfying these requirements

• How and when will these technologies evolve and how may they impact the capabilities, availability and cost of DRO stations

Critical DRO requirements that drive ingest technologies

Automatic FailoverMulti-satellite capability

GOESPOESMETOP, NPOESS

Critical DRO requirements that drive processing technologies

Multilevel Product GenerationAutomated Customer DeliveryQC Logging

Critical technologies that have the most impact on satisfying ingest requirements

Common User InterfaceAutomation ToolsProgrammable front-end hardwareMultiple interface capability:

SCSITCI/IPRS-422IF

Critical technologies that have the most impact on satisfying Product Generation requirements

Error TolerancePerformance LoggingAlgorithm ModularityProgrammer Applications LibrariesManager InterfaceAutomation Tools (ancillary datasets)

How and when will these technologies evolve and how may they impact the capabilities, availability and cost of DRO stations

Technology is driven by high-volume user agencies.Model 1 System: Constant Capability, Decreasing Cost. Model 2 System: Constant Cost, Increasing Capability

Example: Multiple Satellite IngestorSatellite Input

GSI Unit “PRIMARY 1”

GSI Unit “PRIMARY 2”

VISUALIZE

VISUALIZE

PRIMARY 2

PRIMARY 1

1 2 3 4

1 2 3 4

ΗProCurveSwitch 4000M

100/10BT

100/10BT

100/10BT

100/10BT

100/10BT

1Gb-TX

1Gb-TX

1Gb-TX

1Gb-TX

1Gb-TX

1Gb-TX

1Gb-TX

1Gb-TX

VISUALIZE

METOP

GSI Unit “BACKUP 1”

ΗProCurveSwitch 4000M

100/10BT

100/10BT

100/10BT

100/10BT

100/10BT

1Gb-TX

1Gb-TX

1Gb-TX

1Gb-TX

1Gb-TX

1Gb-TX

1Gb-TX

1Gb-TX

1 2 3 4

VISUALIZE

BACKUP 1

1 2 3 4

VISUALIZE

BACKUP 2

GSI Unit “BACKUP 2”

VISUALIZE

1 2 3 4

TEST/DEV

GSI Unit “TEST/DEV”

VISUALIZE

®

i n v e n t

VISUALIZE

®

i n v e n t

10/100BT 10/100/1000BT

10/100BT

10/100/1000BT LAN Switch

10/100BT

10/100BT10/100/1000BT

10/100/1000BT LAN Switch

HP C3650 HP C3650

HP C3650 HP C3650

HP C3650HP C3650

HP X1100 HP X1100

Operator Main PanelSimple control over multiple ingest channels

Channel Processing Status

•Provides a continuous near-real time display of ingest statistics

Ingestion Menus•Enable/Disable Level 0 Ingestion•Enable/Disable Level 1A Ingestion•Select Ingestion Debug Level

Distribution Menu

•Define Destinations to Distribute•Enable/Disable Distribution

Options

•Storage Usage•File System Usage

Browse•AFEP Browse is used to view existing log files

Recommended