View
0
Download
0
Category
Preview:
Citation preview
About LTA Co.,Ltd.About LTA Co.,Ltd.
Lab.Accrediation
• FCC DoC CAB in USA : 610755• IC filing in Canada : IC 5799• NVALP in USA : Code 200723-0• VCCI in Japan :R-4377,C-4378 • MIC EMC in Korea : KR0049• Timco(FCC TCB in USA):• TUV (TUV Nord)• MIC Japan Sub-Lab. • JEL MRA in Japan• CEC recognized in USA• KOLAS (under assessment)
Service scope
• EUR: CE DoC or CoC ;- EMC & LVD Directive- R&TTE Directive
• USA FCC DoC or CoC & Canada IC ;- FCC P.15b,P15c & RSS212,ICES-003,BETS-7
• Korea MIC , eK-mark ;- EMC for ITE ,RF for wireless
• Japan VCCI , PSE, MIC for wireless• The other:C-tick,BSMI,CCC and e-mark• BQE for Bluetooth• CEC(Energy test) in USA
Main Facilities
• Open Area Test Site : 3m or 10m• Frequency : 30MHz ~ 26GHz
• Conducted Emission9kHz~30MHz, 90V~250V, 2kVASoft ware : e3 by Audix in Taiwan
• Harmonics & Flicker Power : AC100-240V,4kVA(NF in Japan)Soft ware : Voltech by UK
Semi-anechoic Chamber(3)
• Distance : 3m• Frequency : 30MHz ~ 26GHz• Size : 8 x 5 x H(3.8) m• Turn Table , ANT Master : Innco GmbH in
Germany• Turn Table specification : 1.2m, 250Kg• Measuring soft ware : e3 by Audix in Taiwan
In side for chamber
DVB-S Test Stream Source
DVB-C Test Stream Source
DVB-T Test Stream Source
The other source : FM,TV..
Measurement room
Immunity facilities(1)• ESD ;
Discharge Voltage : 200V~30kV(Air,Contact)• Surge ;
Pulse amplitude : +/-200V~6kV,1.2/50us,10/700us• Magnetic field ;Field strength : 0.1 ~ 40A/mFrequency : 40 ~ 70Hz
• Bust ;Pulse amplitude : +/- 200V~4.4kV
• Voltage Dip : EUT current : up to 16A off continues,25A short termEUT voltage : up to 260 Vac/dc
Immunity facilities(2)• Conducted EMS System ;
150kHz~230MHzSoft ware : TSJ in Japan
• Radiated EMS System ;80MHz~3GHzSoft ware : TSJ in Japan
(L) RS/CS test systems(R) An-echoic Chamber
Safety R&D, Energy CSA NRTL,CE,UL ,CB eK,CEC ,E3
• IEC/EN/UL 60065 for AV • IEC/EN/UL 60950-1 for ITE• IEC/EN 61010-1 for Equipment• IEC/EN 60335-1 for Home appliance• California Energy Commission in USA ;
Power Supplies , Consumer A/V• Equipment Energy Efficiency in AU ;
Set-top Box….
• Korea : MIC Type approval• USA : FCC P15c,22,24,etc • EUR : R&TTE by N.B.• Japan : MIC (TELEC)• Other DGT,SRRC,
RF & Bluetooth R&D
Tested by LTA
Issued by N.B.
Tested by LTA
Issued by N.B.
-Kor.USA,Japan(Test,Approval)
- BQE Bluetooth :
EUREXCOMM in Japan
-Kor.USA,Japan(Test,Approval)
- BQE Bluetooth :
EUREXCOMM in Japan
Reliability Environmental Test• Temperature : -50℃ ~ 150℃
- Low / High / Storage / Operation / Cycle- Humidity (25~98%)
• Vibration • Drop
Global Network
TIMCO ENGINEERING INC
Japan EMC Laboratory for EMC
DSP Research,Inc ,RFT Ltd.,
Morlab.Co.,Ltd. Audix Taiwan EMC Laboratory
LTA Co.,Ltd. www.ltalab.com
LTA Co.,Ltd.243 Jubug-ri,Yangji-myeon,Cheoin-gu,Yongin-si,Gyeonggi-do,449-822 KOREA
www.ltalab.com Tel : +82-31-323-6008/9 , Fax : +82-31-323-6010info@ltalab.com
Thank you !
Recommended