NOTES:

AT MINIMUM ALL WIRES TO BE SUPPORTED AND SECURED PERCODE REQUIREMENTS. USE CLAMP 10495 OR 10497 OR WIRE TIE8343 OR 108046 AND SCREW G67-XX-XXX OR G56-XX-XXX ASAPPROPRIATE FOR INSTALLATION.

ROUTE TANK SENSOR WIRES SO THEY DO NOT PASSOVERSENSORS. USE WIRE TIE MOUNT 155366-01-000 ANDWIRE TIE 8343-01-000 AS NEEDED. TANK SURFACE MUSTBE CLEANED USING ISOPROPYL ALCOHOL AND PRIMED WITHPRIMER 94.

SEE WIRE ASM-SOLAR COACH AND WIRE INSTL-CHASSISFOR ADDITIONAL INFORMATION.

MOUNT ON EXTERIOR SURFACE OF VAN SIDEWALL.4

CODES/STANDARDS USA

CODES/STANDARDS-CSA/CMVSS

2651B1

1B1

265

SWITCHDETAIL CA

3

1.

2.

4

SWITCHDETAIL CB

SWITCHDETAIL CG

LAMP ASM-PORCH184120-01-CHTSCREWG39-06-10U (2)CONNECTOR58028-01-000 (2)CIRCUITS PJ,NC

PORT-SOLAR,SINGLE,FUSED000169763 / 330845-01-000SCREWG39-10-16U (4)DETAIL AA

4

DETAIL AA

WIRE ASM-SOLARCOACH

YELYEL

WHT BLK

PORT-SOLAR

3

YEL WHT

DETAIL AB

3

UNSPECIFIED TOLERANCES: MATERIAL:

C

D

1

TWO-PLACE (X.XX)

DSNR:

DESCRIPTION:

8

2

B

ALL DIMENSIONS ARE IN MILLIMETERSDFTR:

6

A

6

FIRST USED:

A

REV

WHOLE DIM (X)

D

REF:

8

ITEM/PART NO:

4

WEIGHT: (LBS)

SHEET:

7

B

2

4

REFER TO ES0018 FOR FASTENERTIGHTENING GUIDELINES

ANGLE

5

5

13

COPYRIGHT 2016 WINNEBAGO INDUSTRIES, INC.

ONE-PLACE (X.X)

C

7

WIRING INSTL-BODY,12V

1 OF 6 000186862 / 33514001000

3

1.5

0.50

1

X-X

FORELECTRICAL

CALLOUTSSEE DWG NO.

121339-01-000

FOR ELECTRICALTORQUE

SPECIFICATIONSSEE DWG NO.

128783-01-000

20 T59P

LIGHT-LED,ROUND W/SWITCH,3.5 PLASTIC000166892 / 329927-01-CHT (2)SCREWG13-06-10U (6)CONNECTOR58028-01-000 (4)

RECEPTACLE-12V132958-01-000DETAIL AB

USB-CHARGER DUAL,DC188312-01-000DETAIL AB

WATER SERVICE PANELDETAIL AC

AF

JA

AG

JY

JS

JD

FL

LIGHT-TAPE,LED,DIFFUSED190025-09-CHT

ND

USB-CHARGER DUAL,12V RCP COMBO000183575 / 334237-01-000DETAIL AD

WIRE ASM-SIDEWALL000196665 / 336052-01-000

DETAIL AC

DETAIL AD

WHT

YEL

WHT

YEL

WIRE ASM-GALLEY000187363 / 335244-01-000

WIRE ASM-SOLAR COACH000196866 / 336098-01-000WIRE ASM-SOLAR COACH000217596 / 341171-01-000

SWITCHDETAIL CL

POP TOP-SLEEPING WITHOUT60B

POP TOP - SLEEPING60A

60A

60B

60B

60C

POP TOP-SLEEPNG CUSTOM60C

14-Jan-2022

NOTES:

AT MINIMUM ALL WIRES TO BE SUPPORTED AND SECURED PERCODE REQUIREMENTS. USE CLAMP 10495 OR 10497 OR WIRE TIE8343 OR 108046 AND SCREW G67-XX-XXX OR G56-XX-XXX ASAPPROPRIATE FOR INSTALLATION.

CODES/STANDARDS USA

CODES/STANDARDS-CSA/CMVSS

2651B1

1B1

265

1.

TEMP SENSOR,DATA CABLEJB,JMTO HEATER

2 COAX IS PART OF WIRE ASM-COACH.

SEE DETAIL CH FOR CONNECTION TO SENSOR PROBES.3

3TDTO TRAILERLIGHT CONTROL

WIRE ASM-MONITOR PANEL000040629 / 319486-01-000

5

SEE HEATER INSTALLATION INSTRUCTIONS FORADDITIONAL INFORMATION.

USB-CHARGER DUAL,DC188312-01-000DETAIL AB

5

USB-CHARGER DUAL,DC188312-01-000DETAIL AB

MOUNT ON EXTERIOR SURFACE OF VAN SIDEWALL.4

FA

WIRE ASM-HEATER,TANKS134551-15-000

158

4

7

SHEET:

2

4

C

A

DESCRIPTION:

B

3 2

REV

A

ITEM/PART NO:

3

D

6

78

D

5

B

C

16

WIRING INSTL-BODY,12V

000186862 / 33514001000 2 OF 6

X-X

FORELECTRICAL

CALLOUTSSEE DWG NO.

121339-01-000

FOR ELECTRICALTORQUE

SPECIFICATIONSSEE DWG NO.

128783-01-000

LAMP ASM-PORCH184120-01-CHTSCREW000G39-06-10U (2)CONNECTOR058028-01-000 (2)

3

4

LIGHT-LED,ROUND W/SWITCH,3.5 PLASTIC000166892 / 329927-01-CHT (2)SCREW G13-06-10U (6)CONNECTOR58028-01-000 (4)

LPGD

RECEPTACLE-12V132958-01-000DETAIL BB

RECEPTACLE-12V132958-01-000DETAIL AB

12V FUSESDETAIL CE

GROUND BARDETAIL BA

RESISTOR-10 OHM, 50W171620-01-000PLATE-MOUNTING190836-01-CHTCLAMP-CABLE010495-02-000 (2)SCREWG39-06-06U (2)

WIRE ASM-HEATER RELAY153891-01-000RELAY063912-02-000SCREWG11-008-12U

LABEL-POWER RATING000196807 / 336084-01-CHT

CONNECT ALL GROUNDSTO GROUND BAR

NEGATIVE BAR-FRAME, STEEL140031-01-CHTBOLTC26-06-12U (2)NUTD39-06-00U (2)STUD-ISOLATED086233-01-000 (2)NUTD34-06-00U (2)SCREWG67-10-12U (4)

DETAIL BA

DETAIL BBNE

JE

WIRE ASM-REAR000188884 / 335628-01-000

WIRE ASM-SIDEWALL000196670 / 336053-01-000

WIRE ASM-DINETTE000188885 / 335629-01-000

TIE-WIRE,MOUNT ADHESIVE 1155366-01-000TIE-WIRE008343-01-000

6

USING WIRE TIE MOUNT AND WIRE TIE, SECURE EXCESSWIRE ASM-MONITOR PANEL WIRES TO TANK.

6

BC

60BDETAIL BC

LIGHT-TAPE,LED,DIFFUSED190025-23-CHT

PANEL ASM-TRIM,CAB(REF)

POP TOP-SLEEPING WITHOUT60B

SWITCHDETAIL CC

60B

14-Jan-2022

CODES/STANDARDS USA

CODES/STANDARDS-CSA/CMVSS

2651B1

1B1

265

DETAIL CE

SWITCH-ROCKER108357-18-000ACTUATOR-SWITCH108356-19-CHTWIRE ASM-THERM186796-01-000

DETAIL CB

SWITCH-ROCKER135740-01-CHT (2)SWITCH-BASE135741-02-CHTSWITCH-BEZEL135742-02-CHTSCREWG11-08-08U (4)

DETAIL CA

AJC

PJJC

SWITCH-ROCKER135740-01-CHTSWITCH-BASE135741-01-CHTSWITCH-BEZEL135742-01-CHTSCREWG11-08-08U (2)

DETAIL CC

PEJF

FUSE-15 AMP062901-05-000 (7)

FUSE-5 AMP062901-02-000

LABEL-SWITCH134563-01-CHT

TURN OFF When Not In Use

DETAIL CD

SWITCH-ROCKER135740-06-CHTSWITCH-BASE135741-01-CHTSWITCH-BEZEL135742-01-CHTSCREWG11-08-08U (2)

HOLDING TANK HEATER

SEE OPERATORS MANUAL

HRJP

JA

158

4

7

SHEET:

2

4

C

A

DESCRIPTION:

B

3 2

REV

A

ITEM/PART NO:

3

D

6

78

D

5

B

C

16

WIRING INSTL-BODY,12V

000186862 / 33514001000 3 OF 6

X-X

FORELECTRICAL

CALLOUTSSEE DWG NO.

121339-01-000

FOR ELECTRICALTORQUE

SPECIFICATIONSSEE DWG NO.

128783-01-000

FUSE-20 AMP062901-06-000

PLATE-SWITCH144363-02-CHTSCREWG11-06-10U (2)

JC 14 Y(LIGHTS)

JD 14 Y(LIGHTS)

JE 14 Y(INV. RECEPTACLE)

JF 14 Y(LIGHTS)

JG 14 Y(ROOF COMPONENTS)

JA 12 Y(WATER PUMP)

JB 12 Y(HEATER)

ET 10 Y(REFRIGERATOR)

WB 16 Y(LP DETECTOR)

NM 12 Y(TANK HEATER)

JGRRB

DETAIL CF

SWITCH-ROCKER135740-01-CHTSWITCH-BASE135741-01-CHTSWITCH-BEZEL135742-01-CHTSCREWG11-08-08U (2)

PLATE-SWITCH144363-02-CHTSCREWG11-06-10U (2)

SWITCH-ROCKER108357-01-000ACTUATOR108356-01-CHT

DETAIL CG

NOTES:

1 TYPICAL WIRE ATTACHMENT AT ALL LEVEL PROBES (4 EACH)FOR WATER, MAIN, AND AUX HOLDING TANKS.

TERMINAL-RING(REF)

NUT-WELL(REF)

SCREW143056-01-CHT

WASHER000E13-10-00U

HOLDING TANK WALL(REF)

1DETAIL CJ

DETAIL CH

GND

1/32/3

FULL

WHT

YEL

GRN

ORG

RED

SEE DETAIL CJFOR ATTACHMENTDETAILS

FUSE-10 AMP062901-04-000

L.P.

VALVE

SWITCH-ROCKER135740-01-CHTSWITCH-BASE135741-01-CHTSWITCH-BEZEL135742-59-CHTSCREWG11-08-08U (2)

DETAIL CK

WBKKD

POP TOP-SLEEPING WITHOUT60B

POP TOP - SLEEPING60A

60A

60BDETAIL CL

SWITCH-ROCKER135740-04-CHTSWITCH-BASE135741-01-CHTSWITCH-BEZEL135742-01-CHTSCREWG11-08-08U (2)

JGRRB

RRC

60C

POP TOP-SLEEPNG CUSTOM60C

15

15

15

15

15

15

20

5

15

10

F6F7

F8F9

+VCC

F5F1

F2

POS+

F3F1

0

NEG-

F4F1

1

40

40

14-Jan-2022

CODES/STANDARDS USA

CODES/STANDARDS-CSA/CMVSS

2651B1

1B1

265

NOTES:

AT MINIMUM ALL WIRES TO BE SUPPORTED AND SECURED PERCODE REQUIREMENTS. USE CLAMP 10495 OR 10497 OR WIRE TIE8343 OR 108046 AND SCREW G67-XX-XXX OR G56-XX-XXX ASAPPROPRIATE FOR INSTALLATION.

APPLY TAPE TO OUTSIDE EDGES OF SOLAR PANEL TO SEAL AFTERPANEL IS APPLIED TO POPTOP.

MOUNTED ON INTERIOR SURFACE OF ROOF.

2

3

LIGHT-LED,ROUND 3.5 PLASTIC000166893 / 329928-01-CHT (3)SCREW G13-06-10U (9)CONNECTOR58028-01-000 (6)

1.

3

158

4

7

SHEET:

2

4

C

A

DESCRIPTION:

B

3 2

REV

A

ITEM/PART NO:

3

D

6

78

D

5

B

C

16

WIRING INSTL-BODY,12V

000186862 / 33514001000 4 OF 6

X-X

FORELECTRICAL

CALLOUTSSEE DWG NO.

121339-01-000

FOR ELECTRICALTORQUE

SPECIFICATIONSSEE DWG NO.

128783-01-000

LIGHT-TAPE,LED,DIFFUSED190025-05-CHTCHANNEL-LIGHT,TAPE190097-01-CHT(254 MM)

REMOVE CLEARANCE LIGHTSRUN WIRES TO CUTOUTS IN POPTOPRE-ATTACH LIGHTS TO POPTOP

GROMMET071015-11-000

(VIEW OF OPEN POPTOPFROM REAR)

PANEL-SOLAR 220 WATT, FLEXIBLE000196552 / 336026-01-000TAPE-SEALING000202843 / 337812-01-CHT(5470 MM)WIRE ASM-SOLAR EXTENSION

000198744 / 336547-01-000

WIRE ASM-FRONT CEILING000188862 / 335615-01-000

WIRE ASM-MID CEILING000189204 / 335754-01-000

WIRE ASM-ROOF000188889 / 335632-01-000

WIRE ASM-REAR CEILING000188863 / 335617-01-000

500

83

2

GROMMET071015-18-000

PLATE-ROOF,CABLE ENTRY QUAD146488-03-000

ROUTE WIRES THROUGH HOLE IN TOP OFPOP TOP. SECURE WIRES TO REAR STRUTWITH WIRE TIES (008343-01-000). ROUTEWIRES THROUGH HOLE IN ROOF INTO COACH.

4

4

CONNECT VENDORBLACK WIRETO WINNEBAGOGREEN WIRE

WIRE ASM-ROOF

CONNECT VENDOR REDWIRE TO WINNEBAGOBLACK WIRE THATHAS RED TAPE

DETAIL DA

PORT-SOLAR(REF)

POP TOP-SLEEPING WITHOUT

60A

60B

60A

POP TOP - SLEEPING

60B

PORT-SOLAR, 3 POSITION000170803 / 331218-01-CHTSPACER-VENT000041695 / 319875-01-CHTSPACER-VENT000217773 / 341265-01-CHTSCREWG39-10-16U (4)DETAIL DA

WIRE ASM-ROOF VENT000216672 / 340947-01-000

PANEL-SOLAR 170 WATT000041411 / 318634-02-CHTBRACKET343383-01-CHT (4)BOLT000C12-04-00U (8)LOCKWASHER000E11-04-00U (8)NUT-T343407-01-CHT (8)WIRE ASM-SOLAR EXT, 3 FOOT000220792 / 342332-01-000SCREWG39-10-10U (12)

60B

60B

60A

60A

60A

60A

APPLY ROOF SEALANT (APPROXIMATELY75 MM WIDE) AND PUSH CABLE INTOTHE SEALANT TO STABILIZE THEM WHERE NEEDED.

5

560C

60C

60C

60C

60CPOP TOP-SLEEPNG CUSTOM60C

14-Jan-2022

1.

NOTES:

AT MINIMUM ALL WIRES TO BE SUPPORTED AND SECURED PERCODE REQUIREMENTS. USE CLAMP 10495 OR 10497 OR WIRE TIE8343 OR 108046 AND SCREW G67-XX-XXX OR G56-XX-XXX ASAPPROPRIATE FOR INSTALLATION.

CODES/STANDARDS USA

CODES/STANDARDS-CSA/CMVSS

2651B1

1B1

265

158

4

7

SHEET:

2

4

C

A

DESCRIPTION:

B

3 2

REV

A

ITEM/PART NO:

3

D

6

78

D

5

B

C

16

WIRING INSTL-BODY,12V

000186862 / 33514001000 5 OF 6

FOR ELECTRICALTORQUE

SPECIFICATIONSSEE DWG NO.

128783-01-000

X-X

FORELECTRICAL

CALLOUTSSEE DWG NO.

121339-01-000

SWITCHDETAIL CF

LIGHT-TAPE,LED,DIFFUSED190025-05-CHTCHANNEL-LIGHT,TAPE190097-01-CHT(254 MM)CIRCUITS: RRB,JN

POP TOPENTRANCECUTOUT

WIRE ASM-POP TOP000188890 / 335633-01-000

USB-CHARGER DUAL,12V RCP COMBO000183575 / 334237-01-000DETAIL AD

REMOVE SATELLITE ANTENNAFROM TOP OF VANAND RELOCATE TO POP TOP

ATTACH WIRES FROM WIRE ASM-POP TOP TO COMPONENTSBEFORE POP TOP IS INSTALLED. ROUTE END OF WIRE ASM THROUGH HOLE IN ROOF AS POP TOP IS BEING INSTALLEDFOR LATER CONNECTION.

2

2

2

2

POP TOP - SLEEPING60A

60A

POP TOP-SLEEPNG CUSTOM60C

60C

14-Jan-2022

1.

NOTES:

2 SEE WIRE ASM-SOLAR SYSTEM AND WIRE INSTL-CHASSISFOR ADDITIONAL INFORMATION.

AT MINIMUM ALL WIRES TO BE SUPPORTED AND SECURED PERCODE REQUIREMENTS. USE CLAMP 10495 OR 10497 OR WIRE TIE8343 OR 108046 AND SCREW G67-XX-XXX OR G56-XX-XXX ASAPPROPRIATE FOR INSTALLATION.

CODES/STANDARDS USA

CODES/STANDARDS-CSA/CMVSS

2651B1

1B1

265

SWITCHDETAIL CD

PLATE-TEMP SENSOR192254-01-CHTSENSOR-ROOM TEMPERATURE192038-35-CHT 2

AGW,AGZ(8 GA GRN WITH RED TAPE/10 GA WHT)

AGT,AGY(8 GA BLK WITH RED TAPE/10 GA YEL)

DETAIL FB

158

4

7

SHEET:

2

4

C

A

DESCRIPTION:

B

3 2

REV

A

ITEM/PART NO:

3

D

6

78

D

5

B

C

16

WIRING INSTL-BODY,12V

000186862 / 33514001000 6 OF 6

FOR ELECTRICALTORQUE

SPECIFICATIONSSEE DWG NO.

128783-01-000

X-X

FORELECTRICAL

CALLOUTSSEE DWG NO.

121339-01-000

PANEL-MONITOR000188975 / 335677-01-CHT

PANEL-CP PLUS,US192038-32-CHTFUSE062901-09-000

VIEW FA

SWITCHDETAIL CK

CONTROL-CHARGE, SOLAR 30 AMP000202799 / 337769-01-000DETAIL FB

HT(8 GA GRN WITH GLD TAPE)

HS(8 GA BLK WITH GLD TAPE)

TURN OFF When Not In Use

SEE OPERATORS MANUAL

HOLDING TANK HEATER

GRAYBATT

1/3

FL

E F

G

LPG

C

PUMP ON 2/3

BATTERY

PUMP

WATER

TANKS

VALVE

L.P.

14-Jan-2022