GENERALSystem Presentation (1) 1..........................
ENGINE FIRE PROTECTIONSystem Presentation (1) 5..........................Engine Fire Detection Logic (3) 11.................Fire Push-Button Interfaces (3) 19.................System Warnings (3) 23..............................SYS Operation in Case of ENG Fire in Flight(3) 27.SYS Operation in Case of ENG Fire on GND (3) 31...Precautions (3) 35..................................Components (3) 37...................................Electrical Circuits (3) 45.........................
APU FIRE PROTECTIONSystem Presentation (1) 53.........................APU Fire Detection Logic (3) 59....................Fire Push-Button Interfaces (3) 67.................System Warnings (3) 71..............................** Auto Extinguishing Ground Test (3) 75..........System Operation in Case of APU Fire (3) 79.......Auto Extinguishing on Ground (2) 83................Precautions (3) 87..................................Components (3) 89...................................Electrical Circuits (3) 97.........................
AVIONICS SMOKE DETECTIONSystem Presentation (1) 107........................Smoke Procedures (3) 111............................Components (3) 123..................................
CARGO & LAVATORY FIRE PROTECTIONCargo Fire Protection Syst Presentation (1) 127...Lavatory Fire Protection SYS Presentation(1) 133..** Cargo & Lavatory SMK Detection SYS D/O(3) 137..Cargo Smoke Detection Warnings (3) 143............
Cargo Smoke Procedure (3) 147......................Lavatory Smoke Detection Warnings (3) 151.........Lavatory Waste Bin Fire Extinguishing (3) 155.....** Programming and Test Panel Utilization (2) 159.Precautions (3) 163.................................** Components (3) 165...............................
PORTABLE EQUIPMENTPortable Fire Extinguishers (1) 179................
MAINTENANCE PRACTICESSPECIFIC PAGES** CFDS Specific Page Presentation (3) 183......
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
EFFECTIVITYALL
26 FIRE PROTECTION
UFD4200 TABLE OF CONTENTS Page
26 CONTENTSPage i
Dec 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
EFFECTIVITYALL
26 FIRE PROTECTION
UFD4200 TABLE OF CONTENTS Page
26 CONTENTSPage ii
Dec 31/00
THIS PAGE INTENTIONALLY LEFT BLANK
26 - FIRE PROTECTION
26-00-00 GENERAL SYSTEM PRESENTATION
CONTENTS:GeneralEngine Fire ProtectionAPU Fire ProtectionAvionics Smoke DetectionCargo Fire ProtectionLavatory Fire ProtectionPortable Fire Extinguishers
TMUFIR102 LEVEL 1
EFFECTIVITY 26-00-00 Page 1Apr 30/96
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 1EFFECTIVITYALL
GENERAL SYSTEM PRESENTATION
GENERAL
The fire protection system provides:- Fire detection and extinguishing systems forthe engine and the APU
- Smoke detection and extinguishing systems forthe foward and Aft/Bulk cargo compartment andfor lavatories
- Smoke detection for the avionics compartment- Portable fire extinguisher bottle for fightingfire.
ENGINE FIRE PROTECTION
The engine fire protection is provided by two systems:The fire detection systems and the fire extinguishingsystem.
APU FIRE PROTECTION
The APU fire protection is provided by two systems:The fire detection system and the fire extinguishingsystem.
AVIONICS SMOKE DETECTION
The avionics smoke detection is provided by one smokedetector installed on the air extraction duct in theavionics compartment.
CARGO FIRE PROTECTION
The cargo fire protection is provided by two systems:The cargo smoke detection system and the cargo fireextinguishing system.The forward and Aft/Bulk cargo compartment fireprotection is optional (smoke detection and fireextinguishing separately).Note that an option with a second bottle enables fireextinguishing extended duration for Etops.
LAVATORY FIRE PROTECTION
The lavatory fire protection is provided by twosystems: The lavatory smoke detection system and thewaste bin automatic fire extinguishing system.
PORTABLE FIRE EXTINGUISHERS
The portable fire extinguishers are used for fightingfire in the cockpit and cabin.
TMUFIR102-T01 LEVEL 1
EFFECTIVITY 26-00-00 Page 2Apr 30/96
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 2EFFECTIVITYALL
TMUFIR102-P01 LEVEL 1
GENERAL SYSTEM PRESENTATION
EFFECTIVITY 26-00-00 Page 3Apr 30/96
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 3EFFECTIVITYALL
THIS PAGE INTENTIONALLY LEFT BLANK
TMUFIR102 LEVEL 1
EFFECTIVITY 26-00-00 Page 4Apr 30/96
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 4EFFECTIVITYALL
26 - FIRE PROTECTION
26-12-00 SYSTEM PRESENTATION
CONTENTS:GeneralFire DetectorsFire Detection Unit (FDU)WarningsTest P/BEngine Fire P/BAgent P/BBottlesSelf Examination
TMUFIRA02 LEVEL 1
EFFECTIVITY 26-12-00 Page 1Jul 31/98
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 5EFFECTIVITYALL
SYSTEM PRESENTATION
GENERAL
The engine fire protection is provided by two systems:The fire detection and the fire extinguishing systems.
FIRE DETECTORS
Each engine fire detection system consists of twoindependent loops A and B connected in parallel to theFire Detection Unit (FDU). Each loop comprises threefire detectors connected in parallel. Loops A and Bare connected in parallel to the Fire Detection Unit(FDU). Each loop comprises:
- Fan fire detector- Pylon fire detector- Core fire detector
FIRE DETECTION UNIT (FDU)
One Fire Detection Unit is provided for eachengine. The Fire Detection Unit (FDU) processessignals received from the fire detectors.
WARNINGS
The Fire Detection Unit generates signals for ECAMdisplay, Centralized Fault Display System utilizationand cockpit local warnings.
- Fire warning signals are sent to ECAM and enginefire and start control panels.
- Loop failure warnings are sent to ECAM andCentralized Fault Display System (CFDS).
TEST P/B
On the engine fire panel the TEST pushbutton permitsthe fire detection and the extinguishing systems tobe checked. During the test, the SQUIB lights come onif the continuity of the squib circuit is correct. TheDISCH lights are also activated but as a lamp test.The TEST pushbutton checks simultaneously theintegrity of the:
- Fire detection loops A and B, FDU, indicationsand warnings.
- Squib circuit continuity of AGENT 1 and 2.
ENGINE FIRE P/B
When the ENGINE FIRE pushbutton is released out, theSQUIB lights come on and the extinguishing system isarmed. At the same time, the engine is isolated fromthe other aircraft systems. When the ENG FIREPUSHbutton is released out:
- Both SQUIB lights come on indicating bottlepercussion is available.
- Aircraft systems are isolated.
AGENT P/B
Action on the AGENT pushbutton provides bottledischarge when the ENGINE FIRE PUSHbutton is stillreleased out. A pressure switch activates thecorresponding DISCH light when the agent has beendischarged.
TMUFIRA02-T01 LEVEL 1
EFFECTIVITY 26-12-00 Page 2Jul 31/98
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 6EFFECTIVITYALL
SYSTEM PRESENTATIONTMUFIRA02-P01 LEVEL 1
EFFECTIVITY 26-12-00 Page 3Jul 31/98
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 7EFFECTIVITYALL
SYSTEM PRESENTATION
BOTTLES
Two extinguisher bottles are installed in the pylon.Each bottle is equipped with a pressure switch tomonitor agent pressure and an electrically operatedSQUIB, for agent discharge.
TMUFIRA02-T01 LEVEL 1
EFFECTIVITY 26-12-00 Page 4Jul 31/98
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 8EFFECTIVITYALL
SELF EXAMINATION
Is the extinguishing system controlled by the FDU?A - Yes.B - No.
Where are the fire detectors located?A - On the fan and the turbine.B - On the pylon, the fan and the core.C - On the core and the gearbox
The AGENT pushbutton is active when:A - The corresponding "DISCH" light
illuminates.B - ENGINE FIRE PUSHbutton illuminates.C - ENGINE FIRE PUSHbutton is released out
What does the TEST pushbutton check?A - Only the fire detection loops A and B,
FDU, indications and warnings.B - Only the squib circuit continuity of
AGENT 1 and 2.C - Both simultaneously.
TMUFIRA02 LEVEL 1
EFFECTIVITY 26-12-00 Page 5Jul 31/98
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 9EFFECTIVITYALL
THIS PAGE INTENTIONALLY LEFT BLANK
TMUFIRA02 LEVEL 1
EFFECTIVITY 26-12-00 Page 6Jul 31/98
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 10EFFECTIVITYALL
26 - FIRE PROTECTION
26-12-00 ENGINE FIRE PROTECTION: FIREDETECTION LOGIC
CONTENTS:GeneralFire WarningLoop Fault WarningDetection Fault Warning
TMUFIAA01 LEVEL 3
EFFECTIVITY 26-12-00 Page 1Apr 30/96
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 11EFFECTIVITYALL
ENGINE FIRE PROTECTION: FIRE DETECTION LOGIC
GENERAL
The engine Fire Detection Unit (FDU) has two channelscapable of detecting any case of engine fire and loopfailure. Each channel performs the same detection logicdepending on the loop A and loop B status.
FIRE WARNING
In case of a fire detected on both loops or on oneloop with the other faulty, the channels provide afire warning to the ENGINE FIRE panel, ENGINE STARTcontrol panel and ECAM displays.The fire Detection Unit (FDU) generates a fire warningsignal if any of the following conditions are met:
- Fire on loop A and fire on loop B- Fire on loop A and fault on loop B- Fault on loop A and fire on loop B- Fault on loop A and fault on loop B within5 seconds (both loops broken due to atorching flame).
TMUFIAA01-T01 LEVEL 3
EFFECTIVITY 26-12-00 Page 2Apr 30/96
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 12EFFECTIVITYALL
ENGINE FIRE PROTECTION: FIRE DETECTION LOGIC - FIRE WARNINGTMUFIAA01-P01 LEVEL 3
EFFECTIVITY 26-12-00 Page 3Apr 30/96
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 13EFFECTIVITYALL
ENGINE FIRE PROTECTION: FIRE DETECTION LOGIC
LOOP FAULT WARNING
In case of a loop failure the Fire Detection Unitprovides a loop fault warning signal to the ECAM andCentralized Fault Interface Unit (CFDIU).The Fire Detection Unit (FDU) generates an inoperativesignal if any of the following conditions are met:
- Electrical failure- Integrity failure- Detection of a single loop FIRE during morethan 16s while the other loop is in normalcondition.
TMUFIAA01-T02 LEVEL 3
EFFECTIVITY 26-12-00 Page 4Apr 30/96
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 14EFFECTIVITYALL
ENGINE FIRE PROTECTION: FIRE DETECTION LOGIC - LOOP FAULT WARNINGTMUFIAA01-P02 LEVEL 3
EFFECTIVITY 26-12-00 Page 5Apr 30/96
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 15EFFECTIVITYALL
ENGINE FIRE PROTECTION: FIRE DETECTION LOGIC
DETECTION FAULT WARNING
The detection fault logic is based on a dual loopfailure. It corresponds to a total loss of thedetection system.When the Fire Detection Unit generates two inoperativesignals corresponding to loop A and loop B fault logic,the Flight Warning Computer (FWC) elaborates the faultwarning.
TMUFIAA01-T03 LEVEL 3
EFFECTIVITY 26-12-00 Page 6Apr 30/96
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 16EFFECTIVITYALL
ENGINE FIRE PROTECTION: FIRE DETECTION LOGIC - DETECTION FAULT WARNINGTMUFIAA01-P03 LEVEL 3
EFFECTIVITY 26-12-00 Page 7Apr 30/96
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 17EFFECTIVITYALL
THIS PAGE INTENTIONALLY LEFT BLANK
TMUFIAA01 LEVEL 3
EFFECTIVITY 26-12-00 Page 8Apr 30/96
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 18EFFECTIVITYALL
26 - FIRE PROTECTION
26-12-00 ENGINE FIRE PROTECTION - FIREPUSHBUTTON INTERFACES
CONTENTS:GeneralMonitoring InterfacesSupply InterfacesSelf Examination
TMUFIRH01 LEVEL 3
EFFECTIVITY 26-12-00 Page 1Jun 30/94
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 19EFFECTIVITYALL
ENGINE FIRE PROTECTION - FIRE PUSHBUTTON INTERFACES
GENERAL
During the engine fire procedure, the ENGINE FIREPUSHbutton is manually released out. This triggersseveral automatic sequences simplifying further crewactions and system monitoring.
MONITORING INTERFACES
Releasing the fire pushbutton out, cancels theContinuous Repetitive Chime, signals the action to theFlight Warning Computer (FWC) for further managementof other warnings and messages and illuminates theSQUIB light on the Engine Fire Control panel.
SUPPLY INTERFACES
Quick isolation of all systems on the related enginewhich could be the origin of the fire or feed the fireis achieved as soon as the fire pushbutton is releasedout. These systems are:
- Fuel.- Air.- Electric Power.- Hydraulic Power.
The electric supply to the Engine Interface (EIU) isalso disconnected.
TMUFIRH01-T01 LEVEL 3
EFFECTIVITY 26-12-00 Page 2Jun 30/94
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 20EFFECTIVITYALL
ENGINE FIRE PROTECTION - FIRE PUSHBUTTON INTERFACESTMUFIRH01-P01 LEVEL 3
EFFECTIVITY 26-12-00 Page 3Jun 30/94
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 21EFFECTIVITYALL
SELF EXAMINATION
When the ENG FIRE PUSHbutton is released out, whichcorresponding fire valves are closed?
A - Fuel crossfeed valve.B - LP fuel and hydraulic fire Shut Off
Valves.C - HP fuel Shut Off Valve.
When the ENG FIRE PUSHbutton is released out, arethe bleed and the pack valves closed?
A - Yes.B - No.
When the ENG FIRE PUSHbutton is released out, whathappens to the electrical generation?
A - IDG de-energized.B - IDG disconnect.C - IDG energized.
TMUFIRH01 LEVEL 3
EFFECTIVITY 26-12-00 Page 4Jun 30/94
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 22EFFECTIVITYALL
26 - FIRE PROTECTION
26-12-00 ENGINE FIRE PROTECTION
CONTENTS:System Warnings
TMUFIR401 LEVEL 3
EFFECTIVITY 26-12-00 Page 1Dec 31/95
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 23EFFECTIVITYALL
ENGINE FIRE PROTECTION
SYSTEM WARNINGS
When an engine fire is detected, the continuousrepetitive chime sounds, the MASTER WARNING flashes,the ENGINE FIRE PUSHbutton light and the FIRE lighton the ENGINE start panel come on.ENGINE FIRE appears on the Engine Warning display.
TMUFIR401-T01 LEVEL 3
EFFECTIVITY 26-12-00 Page 2Dec 31/95
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 24EFFECTIVITYALL
ENGINE FIRE PROTECTION - SYSTEM WARNINGSTMUFIR401-P01 LEVEL 3
EFFECTIVITY 26-12-00 Page 3Dec 31/95
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 25EFFECTIVITYALL
THIS PAGE INTENTIONALLY LEFT BLANK
TMUFIR401 LEVEL 3
EFFECTIVITY 26-12-00 Page 4Dec 31/95
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 26EFFECTIVITYALL
26 - FIRE PROTECTION
26-12-00 ENGINE FIRE PROTECTION - SYSTEMOPERATION IN CASE OF ENGINE FIRE
CONTENTS:GeneralFire Procedure
TMUFIR502 LEVEL 3
EFFECTIVITY 26-12-00 Page 1Nov 30/98
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 27EFFECTIVITYALL
ENGINE FIRE PROTECTION - SYSTEM OPERATION IN CASE OF ENGINE FIRE
GENERAL
The following fire procedure describes the actions tobe performed by the cockpit crew when an engine firewarning occurs in flight. The procedure takes Engine2 as an example.
FIRE PROCEDURE
When a fire is detected, the continuous repetitivechime sounds, the MASTER WARNING flashes, the ENGINEFIRE PUSHbutton light comes on and the FIRE light onthe ENGINE start control panel comes on.
- Select MASTER WARNING. The MASTER WARNING lightgoes off and the Continuous Repetitive Chimestop.
- Select thrust lever to IDLE.- Select ENG MASTER 2 lever to OFF. When theMASTER lever is set to OFF, the low pressureand the high pressure fuel valves close andcause engine shutdown.
- Select ENG 2 FIRE PUSHbutton.When the ENGINE FIRE PUSHbutton is released out thesingle chime sounds. The MASTER CAUTION comes on dueto systems deactivation.The fuel low pressure valve closure is confirmed. TheSQUIB lights come on on the AGENT pushbuttons toindicate that AGENT pushbuttons can be used.Wait for 10 seconds: this is required to reduce enginewindmilling, reducing the nacelle ventilation whichincreases the agent effect.
- Select AGENT 1 pushbutton.
When the AGENT 1 pushbutton is pressed, fire bottleone is discharged in the engine compartment and theDISCH light comes on.If the fire still persists after 30 seconds, the secondbottle must be discharged.
- Select AGENT 2 pushbutton.When the fire is extinguished, the ENGINE FIREPUSHbutton light and the FIRE indication on the ENGINESTART panel go off.
TMUFIR502-T01 LEVEL 3
EFFECTIVITY 26-12-00 Page 2Nov 30/98
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 28EFFECTIVITYALL
ENGINE FIRE PROTECTION - SYSTEM OPERATION IN CASE OF ENGINE FIRETMUFIR502-P01 LEVEL 3
EFFECTIVITY 26-12-00 Page 3Nov 30/98
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 29EFFECTIVITYALL
THIS PAGE INTENTIONALLY LEFT BLANK
TMUFIR502 LEVEL 3
EFFECTIVITY 26-12-00 Page 4Nov 30/98
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 30EFFECTIVITYALL
26 - FIRE PROTECTION
26-12-00 ENGINE FIRE PROTECTION - SYSTEMOPERATION IN CASE OF ENGINE FIREON GROUND
CONTENTS:GeneralFire Procedure
TMUFIR602 LEVEL 3
EFFECTIVITY 26-12-00 Page 1Apr 30/96
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 31EFFECTIVITYALL
ENGINE FIRE PROTECTION - SYSTEM OPERATION IN CASE OF ENGINE FIRE ON GROUND
GENERAL
The following fire procedure describes the actions tobe performed by the cockpit crew when an engine firewarning occurs on ground.The procedure takes Engine 2 as an example.
FIRE PROCEDURE
When fire is detected, the continuous repetitive chimesounds, the MASTER WARNING flashes, the ENGINE FIREPUSHbutton light comes on and the FIRE light on theENGINE start panel comes on.
- Select MASTER WARNING Pushbutton. The MASTERWARNING light goes off and the ContinousRepetitive Chime stops
- As the rolling speed of the aircraft does notexceed V1, the crew must stop the aircraft.
- Select thrust levers to IDLE. Note that Full Reverse may be used to stop the aircraft.When the aircraft is stopped and parking brake is setto ON.
- Select ENG MASTER 2 lever to OFF.When the MASTER lever is set to OFF, the low pressureand high pressure valves close and cause engineshutdown.
- Select ENG 2 FIRE PUSHbutton.When the ENGINE FIRE PUSHbutton is released out thesingle chime sounds. The fuel low pressure valve closure is confirmed. TheSQUIB lights on the AGENT pushbuttons come on toindicate that AGENT pushbuttons can be used. The MASTERCAUTION comes on due to systems deactivation.
- Select AGENT 1 pushbutton.When the AGENT 1 pushbutton is pressed, fire bottleone is discharged in the engine compartment and theDISCH light comes on.
- Select AGENT 2 pushbutton.When the AGENT 2 pushbutton is pressed, the secondfire bottle is discharged in the engine compartmentand the DISCH light comes on.
- Select ENG MASTER 1 lever to OFF.When the second engine is shut down, if the APU is notrunning the ECAM displays are lost.If the APU is running, it must be shut down.
TMUFIR602-T01 LEVEL 3
EFFECTIVITY 26-12-00 Page 2Apr 30/96
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 32EFFECTIVITYALL
ENGINE FIRE PROTECTION - SYSTEM OPERATION IN CASE OF ENGINE FIRE ON GROUNDTMUFIR602-P01 LEVEL 3
EFFECTIVITY 26-12-00 Page 3Apr 30/96
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 33EFFECTIVITYALL
THIS PAGE INTENTIONALLY LEFT BLANK
TMUFIR602 LEVEL 3
EFFECTIVITY 26-12-00 Page 4Apr 30/96
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 34EFFECTIVITYALL
26 - FIRE PROTECTION
26-12-00 ENGINE FIRE PROTECTION:PRECAUTIONS
CONTENTS:GeneralFire BottleDischarge Cartridge
TMUFIAZ02 LEVEL 3
EFFECTIVITY 26-12-00 Page 1May 31/94
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 35EFFECTIVITYALL
ENGINE FIRE PROTECTION: PRECAUTIONS
GENERAL
Specific precautions must be taken during removal orinstallation of a fire extinguishing bottle and adischarge cartridge.
FIRE BOTTLE
WARNING: The fire bottle cartridges are explosive.Remove them before working on the bottle.Protective caps must be installed duringbottle removal/installation to preventdamage to discharge diaphragm which couldresult in injury to personnel.
DISCHARGE CARTRIDGE
WARNING: Before power is supplied to the aircraft makecertain that electrical circuits upon whichwork is in progress are isolated.
WARNING: Cartridges are class "C" explosives and mustbe handled or stored by authorized personnelor disposed of by an approved method.When cartridge electrical connectors aredisconnected, the cartridge electrical pinsmust be shunted with a protective shunt whichis provided by the manufacturer. A shunt plugor shorting clip, will prevent bottledischarge which could cause injury tomaintenance personnel.The cartridge installed must be of the samemake as the fire bottle and correspond to thespecification indicated in the MaintenanceManual.
TMUFIAZ02-T01 LEVEL 3
EFFECTIVITY 26-12-00 Page 2May 31/94
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 36EFFECTIVITYALL
26 - FIRE PROTECTION
26-12-00 ENGINE FIRE PROTECTION:COMPONENTS
CONTENTS:Fire Detection Unit (FDU)Fire BottlesFire Detectors
TMUFIRJ06 LEVEL 3
EFFECTIVITY 26-12-00 Page 1Jul 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 37EFFECTIVITYALL
ENGINE FIRE PROTECTION: COMPONENTS
SAFETY PRECAUTIONS
WARNING:
Cartridges are explosive, remove them before workingon the bottle. Protective caps must be installed duringbottle removal/installation to prevent damage to thedischarge diaphragm which could result in injury topersonnel.
Before power is spplied to the aircraft make certainthat electrical circuits upon which work is in progressare isolated.Discharge cartridges are class "c" explosives and mustbe handled/stored by authorized personnel or disposedof by an approved method.When cartridge electrical connectors are disconnectedthe cartridge electrical pins must be shunted with aprotective shunt which is provided by the manufacturer.A shunt plug or shorting clip will prevent bottledischarge which could cause injury to maintenancepersonnel.The cartridge installed must be of the same make asthe bottle and correspond to the specificationindicated in the Maintenance Manual.
TMUFIRJ06-T01 LEVEL 3
EFFECTIVITY 26-12-00 Page 2Jul 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 38EFFECTIVITYALL
THIS PAGE INTENTIONALLY LEFT BLANK
TMUFIRJ06 LEVEL 3
EFFECTIVITY 26-12-00 Page 3Jul 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 39EFFECTIVITYALL
FIRE DETECTION UNIT (FDU)
IDENTIFICATIONFIN: 2WD1, 2WD2
LOCATIONZONE: 126
COMPONENT DESCRIPTIONFIRE DETECTION UNIT(S):- ENG1- ENG2
FIRE BOTTLES
IDENTIFICATIONFIN: 6WE2, 8WE2
LOCATIONZONE: 425
COMPONENT DESCRIPTION- Two per engine.- type of agent: bromotrifluoromethane.- Nominal Nitrogen pressure: at 21 deg.C, 600 psi.
PRESSURE SWITCHThe pressure switch is calibrated at:- 450 psi when the pressure increases (refilling).- 225/275 psi when the pressure decreases (dischargeor leak).A spring loaded finger permits the electricalcontinuity of the pressure switch to be manuallychecked.
DISCHARGE HEADThe discharge head has a leakproof metallic diaphragm.The rupture of the leakproof metallic diaphragm, iscaused by:- Gas pressure released after cartridge firing.- An excessive pressure (between 1600 to 1800 psi at95 deg.C, 203 deg.F), in the extinguisher bottle, incase of overheat condition in the engine pylon. Thefull quantity of the agent is released into thenacelle.
SQUIBThe squib is an electro pyrotechnic cartridgecontaining explosive powder, fired by two filamentssupplied with 28 VDC.
WARNING: Never check the continuity of the squib using aconventional ohmmeter.
TMUFIRJ06-T02 LEVEL 3
EFFECTIVITY 26-12-00 Page 4Jul 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 40EFFECTIVITYALL
ENGINE FIRE PROTECTION: COMPONENTSFIRE DETECTION UNIT (FDU) - FIRE BOTTLEST
MUFIRJ06-P02 LEVEL 3
EFFECTIVITY 26-12-00 Page 5Jul 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 41EFFECTIVITYALL
FIRE DETECTORS
COMPONENT DESCRIPTIONThe detector is pneumatically operated by heating itssensing element which contains helium gas and anhydrogen charged core material.
Alarm StateThe application of heat to the sensor causes anincrease of the gas pressure which in turn closes thealarm switch. The detector sends a fire signal.
Fault StateIn the event of gas pressure loss, the integrity switchopens and generates a fault signal.
PYLON FIRE DETECTORS
IDENTIFICATIONFIN: 3WD2, 4WD2
LOCATIONZONE: 425
CORE FIRE DETECTORS
IDENTIFICATIONFIN: 4001WD1, 4001WD2
LOCATIONZONE: 463
FAN FIRE DETECTORS
IDENTIFICATIONFIN: 4000WD1, 4000WD2
LOCATIONZONE: 445
TMUFIRJ06-T03 LEVEL 3
EFFECTIVITY 26-12-00 Page 6Jul 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 42EFFECTIVITYALL
ENGINE FIRE PROTECTION: COMPONENTS - FIRE DETECTORSFAN AND PYLON FIRE DET. - PYLON FIRE DET. - FAN FIRE DET. - CORE FIRE DET.
TMUFIRJ06-P03 LEVEL 3
EFFECTIVITY 26-12-00 Page 7Jul 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 43EFFECTIVITYALL
THIS PAGE INTENTIONALLY LEFT BLANK
TMUFIRJ06 LEVEL 3
EFFECTIVITY 26-12-00 Page 8Jul 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 44EFFECTIVITYALL
26 - FIRE PROTECTION
26-12-00 ENGINE FIRE PROTECTION:ELECTRICAL CIRCUITS
CONTENTS:DetectionExtinguishingInterfaces
TMUFIRQ01 LEVEL 3
EFFECTIVITY 26-12-00 Page 1May 31/94
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 45EFFECTIVITYALL
TMUFIRQ01-P01 LEVEL 3
ENGINE FIRE PROTECTION: ELECTRICAL CIRCUITS - DETECTION
EFFECTIVITY 26-12-00 Page 2May 31/94
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 46EFFECTIVITYALL
TMUFIRQ01-P02 LEVEL 3
ENGINE FIRE PROTECTION: ELECTRICAL CIRCUITS - EXTINGUISHING
EFFECTIVITY 26-12-00 Page 3May 31/94
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 47EFFECTIVITYALL
TMUFIRQ01-P03 LEVEL 3
ENGINE FIRE PROTECTION: ELECTRICAL CIRCUITS - TEST
EFFECTIVITY 26-12-00 Page 4May 31/94
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 48EFFECTIVITYALL
TMUFIRQ01-P04 LEVEL 3
ENGINE FIRE PROTECTION: ELECTRICAL CIRCUITS - ENG 2 FIRE PUSH
EFFECTIVITY 26-12-00 Page 5May 31/94
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 49EFFECTIVITYALL
TMUFIRQ01-P05 LEVEL 3
ENGINE FIRE PROTECTION: ELECTRICAL CIRCUITS - DISCH
EFFECTIVITY 26-12-00 Page 6May 31/94
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 50EFFECTIVITYALL
TMUFIRQ01-P06 LEVEL 3
ENGINE FIRE PROTECTION: ELECTRICAL CIRCUITS - INTERFACES
EFFECTIVITY 26-12-00 Page 7May 31/94
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 51EFFECTIVITYALL
THIS PAGE INTENTIONALLY LEFT BLANK
TMUFIRQ01 LEVEL 3
EFFECTIVITY 26-12-00 Page 8May 31/94
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 52EFFECTIVITYALL
26 - FIRE PROTECTION
26-13-00 SYSTEM PRESENTATION
CONTENTS:GeneralFire DetectorFire Detection Unit (FDU)WarningsTest P/BAuto ExtinguishingAPU Fire P/BAgent P/BBottleRed DiscSelf Examination
TMUFIRB02 LEVEL 1
EFFECTIVITY 26-13-00 Page 1Aug 31/98
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 53EFFECTIVITYALL
SYSTEM PRESENTATION
GENERAL
The APU fire protection is provided by two systems :The fire detection system and the fire extinguishingsystem.
FIRE DETECTOR
The fire detection system consists of two independentloops (A and B). Each loop comprises one fire detector.Loops A and B are connected in parallel to a FireDetection Unit (FDU).
FIRE DETECTION UNIT (FDU)
A Fire Detection Unit is provided for the APU. TheFire Detection Unit (FDU) processes signals receivedfrom the fire detectors.
WARNINGS
The Fire Detection Unit generates signals for ECAMdisplay, Centralized Fault Display Systemutilization and cockpit local warnings.
- Fire warning signals are sent to ECAM, APU firepanel and external power control panel whenaircraft is on ground.
- Loop failure warnings are sent to ECAM andCentralized Fault Display System (CFDS).
TEST P/B
On the APU FIRE panel a TEST pushbutton permits thefire detection and the extinguishing systems to bechecked. During the TEST, the SQUIB light comes on ifthe continuity of the squib circuit is correct. TheDISCH light is also activated but as a lamp test.The TEST pushbutton checks simultaneously theintegrity of:
- Fire detection loops A and B, FDU, indicationsand warnings.
- Squib circuit continuity.
AUTO EXTINGUISHING
If an APU fire occurs while on ground, the APU isautomatically shutdown and the fire extinguishingsystem automatically triggered.
APU FIRE P/B
When the APU FIRE PUSHbutton is released out:- the SQUIB light comes on indicating bottlepercussion is available,
- and APU systems are isolated.
AGENT P/B
Action on the AGENT pushbutton provides bottledischarge if the APU FIRE PUSHbutton is still releasedout. A pressure switch activates the DISCH light whenthe agent has been discharged.
TMUFIRB02-T01 LEVEL 1
EFFECTIVITY 26-13-00 Page 2Aug 31/98
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 54EFFECTIVITYALL
SYSTEM PRESENTATIONTMUFIRB02-P01 LEVEL 1
EFFECTIVITY 26-13-00 Page 3Aug 31/98
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 55EFFECTIVITYALL
SYSTEM PRESENTATION
BOTTLE
An extinguisher bottle is installed outside of the APUcompartment, forward of the firewall. The bottle isequipped with a pressure switch to monitor agentpressure and an electrically operated squib for agentdischarge.
RED DISC
A red disc is visible from outside. The absence of thered disc indicates bottle overpressure discharge.
TMUFIRB02-T01 LEVEL 1
EFFECTIVITY 26-13-00 Page 4Aug 31/98
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 56EFFECTIVITYALL
SELF EXANIMATION
How is an APU fire on ground normally extinguished?A - From APU FIRE panel.B - Automatically.C - From EXTERNAL POWER panel.
How can a thermal discharge of the bottle bedetected on a cold aircraft?
A - By the FDU.B - By the ECAM.C - By the red disc indicator.
How many fire detectors does the APU fire detectionsystem comprise?
A - Three.B - Two.C - One.
TMUFIRB02 LEVEL 1
EFFECTIVITY 26-13-00 Page 5Aug 31/98
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 57EFFECTIVITYALL
THIS PAGE INTENTIONALLY LEFT BLANK
TMUFIRB02 LEVEL 1
EFFECTIVITY 26-13-00 Page 6Aug 31/98
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 58EFFECTIVITYALL
26 - FIRE PROTECTION:
26-12-00 APU FIRE PROTECTION: FIREDETECTION LOGIC
CONTENTS:GeneralFire WarningLoop Fault WarningDetection Fault Warning
TMUFIAB01 LEVEL 3
EFFECTIVITY 26-12-00 Page 1Aug 31/96
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 59EFFECTIVITYALL
APU FIRE PROTECTION: FIRE DETECTION LOGIC
GENERAL
The APU Fire Detection Unit (FDU) has two channelscapable of detecting any case of APU fire and loopfailure. Each channel performs the same detection logicdepending on the loop A and loop B status.
FIRE WARNING
In case of a fire detected on both loops or on oneloop with the other faulty, the channels provide afire warning to the APU FIRE panel, EXTERNAL POWERCONTROL panel and ECAM displays.The Fire Detection Unit (FDU) generates a fire warningsignal if any of the following conditions are met :
- Fire on loop A and fire on loop B- Fire on loop A and fault on loop B- Fault on loop A and fire on loop B- Fault on loop A and fault on loop B within5 seconds (both loops broken due to atorching flame).
TMUFIAB01-T01 LEVEL 3
EFFECTIVITY 26-12-00 Page 2Aug 31/96
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 60EFFECTIVITYALL
APU FIRE PROTECTION: FIRE DETECTION LOGIC - FIRE WARNINGTMUFIAB01-P01 LEVEL 3
EFFECTIVITY 26-12-00 Page 3Aug 31/96
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 61EFFECTIVITYALL
APU FIRE PROTECTION: FIRE DETECTION LOGIC
LOOP FAULT WARNING
In case of a loop failure the Fire Detection Unitprovides a loop fault warning signal to the ECAM andCentralized Fault Display Interface Unit (CFDIU).The Fire Detection Unit (FDU) generates an inoperativesignal if any of the following conditions are met:
- Electrical failure- Integrity failure- Detection of a single loop FIRE during morethan 16s while the other loop is in normalcondition.
An electrical failure is signaled by a loop faultmessage if there is a loss of electrical power of theAPU fire detection system.An integrity failure is signaled by a loop faultmessage if there is a loss of pressure in a Fire SensorElement.
TMUFIAB01-T02 LEVEL 3
EFFECTIVITY 26-12-00 Page 4Aug 31/96
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 62EFFECTIVITYALL
APU FIRE PROTECTION: FIRE DETECTION LOGIC - LOOP FAULT WARNINGTMUFIAB01-P02 LEVEL 3
EFFECTIVITY 26-12-00 Page 5Aug 31/96
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 63EFFECTIVITYALL
APU FIRE PROTECTION: FIRE DETECTION LOGIC
DETECTION FAULT WARNING
The detection fault logic is based on a dual loopfailure. It corresponds to a total loss of thedetection system.When the Fire Detection Unit generates two inoperativesignals corresponding to loop A and loop B fault logic,the Flight Warning Computer (FWC) elaborates adetection fault warning.
TMUFIAB01-T03 LEVEL 3
EFFECTIVITY 26-12-00 Page 6Aug 31/96
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 64EFFECTIVITYALL
APU FIRE PROTECTION: FIRE DETECTION LOGIC - DETECTION FAULT WARNINGTMUFIAB01-P03 LEVEL 3
EFFECTIVITY 26-12-00 Page 7Aug 31/96
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 65EFFECTIVITYALL
THIS PAGE INTENTIONALLY LEFT BLANK
TMUFIAB01 LEVEL 3
EFFECTIVITY 26-12-00 Page 8Aug 31/96
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 66EFFECTIVITYALL
26 - FIRE PROTECTION
26-13-00 APU FIRE PROTECTION - FIREPUSHBUTTON INTERFACES
CONTENTS:GeneralMonitoring InterfacesSupply InterfacesAuto Extinguishing on GroundSelf Examination
TMUFIRI01 LEVEL 3
EFFECTIVITY 26-13-00 Page 1Aug 31/98
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 67EFFECTIVITYALL
APU FIRE PROTECTION - FIRE PUSHBUTTON INTERFACES
GENERAL
During the APU fire procedure, the APU FIRE PUSHbuttonis manually released out. This triggers severalautomatic sequences simplifying further crew actionsand system monitoring.
MONITORING INTERFACES
Releasing the fire pushbutton out, cancels theContinuous Repetitive Chime, signals the action to theFlight Warning Computer (FWC), for further managementof other warnings and messages and illuminates theSQUIB light on the APU Fire Control panel.
SUPPLY INTERFACES
Quick isolation of all systems on the APU which couldbe the origin of the fire or feed the fire is achievedas soon as the fire pushbutton is released out.These systems are:
- Fuel.- Air.- Electric Power.
The Electronic Control Box (ECB) of the APU istriggered to initiate an emergency APU shutdown.
AUTO EXTINGUISHING ON GROUND
When an APU fire is detected on ground, the APU shutsdown automatically and the fire extinguishing systemis automatically triggered.
TMUFIRI01-T01 LEVEL 3
EFFECTIVITY 26-13-00 Page 2Aug 31/98
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 68EFFECTIVITYALL
APU FIRE PROTECTION - FIRE PUSHBUTTON INTERFACESTMUFIRI01-P01 LEVEL 3
EFFECTIVITY 26-13-00 Page 3Aug 31/98
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 69EFFECTIVITYALL
SELF EXAMINATION
When the APU FIRE pushbutton is released out, whichvalve is affected?
A - LP Fuel SOV.B - Hydraulic Fire SOV.C - Fuel Isolation Valve.
Is the APU bleed air supply maintained when the APUFIRE pushbutton is released out?
A - No.B - Yes.
When the APU FIRE pushbutton is released out, whathappens to the electrical generation?
A - APU generator is de-energized.B - APU generator is disconnected.C - APU generator is energized.
TMUFIRI01 LEVEL 3
EFFECTIVITY 26-13-00 Page 4Aug 31/98
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 70EFFECTIVITYALL
26 - FIRE PROTECTION
26-13-00 APU FIRE PROTECTION
CONTENTS:System Warnings (APU FIRE IN FLIGHT)
TMUFIR901 LEVEL 3
EFFECTIVITY 26-13-00 Page 1May 31/96
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 71EFFECTIVITYALL
APU FIRE PROTECTION
SYSTEM WARNINGS (APU FIRE IN FLIGHT)
When an APU fire is detected, the continuous repetitivechime sounds, the MASTER WARNING flashes and the APUFIRE pushbutton light comes on. The APU FIRE procedureappears on the Engine Warning display.
TMUFIR901-T01 LEVEL 3
EFFECTIVITY 26-13-00 Page 2May 31/96
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 72EFFECTIVITYALL
APU FIRE PROTECTION - SYSTEM WARNINGS (APU FIRE IN FLIGHT)TMUFIR901-P01 LEVEL 3
EFFECTIVITY 26-13-00 Page 3May 31/96
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 73EFFECTIVITYALL
THIS PAGE INTENTIONALLY LEFT BLANK
TMUFIR901 LEVEL 3
EFFECTIVITY 26-13-00 Page 4May 31/96
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 74EFFECTIVITYALL
26 - FIRE PROTECTION
26-13-00 APU FIRE PROTECTION: AUTOEXTINGUISHING GROUND TEST
CONTENTS:Auto Extinguishing Ground Test
TMUFIRN01 LEVEL 3
EFFECTIVITY 26-13-00 Page 1Aug 31/96
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 75EFFECTIVITYALL
APU FIRE PROTECTION: AUTO EXTINGUISHING GROUND TEST
The test is performed from the maintenance panel.
CAUTION: This test has to be performed with the APUshutdown and the MASTER SWitch in the ONposition.
- Select AUTO EXTING TEST pushbutton.When the TEST pushbutton is pressed, the ON light andthe APU FIRE PUSH light come on.The squib circuit is isolated during the test.The FUEL LP/ISOL VALVE closes and the EMER SHUT DOWNcontrol relay is energized.After a time delay, the external horn sounds, the APUFIRE light on the external power receptacle panel andthe OK light on the TEST pushbutton come on.The illuminated OK light indicates the correct autoextinguishing relay operation.
- Select the RESET pushbutton.When the RESET pushbutton is pressed, the OK light,ON light, APU FIRE PUSH light and APU FIRE light gooff. The external horn stops.Three seconds after the reset, the automaticextinguishing circuit is recovered.
TMUFIRN01-T01 LEVEL 3
EFFECTIVITY 26-13-00 Page 2Aug 31/96
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 76EFFECTIVITYALL
APU FIRE PROTECTION: AUTO EXTINGUISHING GROUND TESTTMUFIRN01-P01 LEVEL 3
EFFECTIVITY 26-13-00 Page 3Aug 31/96
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 77EFFECTIVITYALL
THIS PAGE INTENTIONALLY LEFT BLANK
TMUFIRN01 LEVEL 3
EFFECTIVITY 26-13-00 Page 4Aug 31/96
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 78EFFECTIVITYALL
26 - FIRE PROTECTION
26-13-00 APU FIRE PROTECTION
CONTENTS:System Operation in Case of APU Fire (ManualExtinguishing)
TMUFIR701 LEVEL 3
EFFECTIVITY 26-13-00 Page 1May 31/96
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 79EFFECTIVITYALL
APU FIRE PROTECTION
SYSTEM OPERATION IN CASE OF APU FIRE (ManualExtinguishing)
APU running in flight:When a fire is detected, the continuous repetitivechime sounds, the MASTER WARNING flashes and the APUFIRE pushbutton light on the APU FIRE panel comes on.- Select the APU FIRE pushbutton.When the APU FIRE pushbutton is released out, thecontinuous repetitive chime stops, the Fuel LowPressure Shutoff valve and the Fuel Solenoid valveclose and cause APU shutdown.The single Chime sounds, the MASTER CAUTION and theFAULT LIGHT on the APU MASTER switch pushbutton comeon. The SQUIB light comes on to indicate that the AGENTpushbutton can be used.The Electronic Control Box (ECB) controls the closureof the fuel valves.A ten seconds delay allows the airflow to reduce, thisincreases the agent effect.- Select the AGENT pushbutton .When AGENT pushbutton is pressed, the fire bottle isdischarged in the APU compartment and the DISCH lightcomes on.When the fire is extinguished, the MASTER WARNING andthe APU FIRE pushbutton lights go off.- Select APU MASTER SWITCH .When the APU MASTER SWITCH pushbutton is released out,the FAULT light goes off.
TMUFIR701-T01 LEVEL 3
EFFECTIVITY 26-13-00 Page 2May 31/96
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 80EFFECTIVITYALL
APU FIRE PROTECTION - SYSTEM OPERATION IN CASE OF APU FIRE (Manual Extinguishing)TMUFIR701-P01 LEVEL 3
EFFECTIVITY 26-13-00 Page 3May 31/96
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 81EFFECTIVITYALL
THIS PAGE INTENTIONALLY LEFT BLANK
TMUFIR701 LEVEL 3
EFFECTIVITY 26-13-00 Page 4May 31/96
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 82EFFECTIVITYALL
26 - FIRE PROTECTION
26-13-00 APU FIRE PROTECTION
CONTENTS:Auto Extinguishing on Ground
TMUFIR801 LEVEL 3
EFFECTIVITY 26-13-00 Page 1Jul 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 83EFFECTIVITYALL
APU FIRE PROTECTION
AUTO EXTINGUISHING ON GROUND
The aircraft is on ground, and the APU is runningwithout supervision:- When a fire is detected, the continuous repetitivechime sounds, the MASTER WARNING flashes and the APUFIRE pushbutton light on the APU FIRE panel comes on.The APU FIRE light on the EXTERNAL POWER panel comeson, the external horn sounds.The fuel low pressure shutoff valve and the fuelsolenoid valve close and the APU shuts down.The single chime sounds, THE MASTER CAUTION and theFAULT light on the APU MASTER SWITCH pushbutton comeon.Three seconds later, the APU fire bottle is dischargedautomatically and the DISCH light on the AGENTpushbutton comes on.- When the fire is extinguished, the MASTER WARNING.the APU FIRE pushbutton light on the APU FIRE paneland the APU FIRE light on the EXTERNAL POWER panel gooff, the external horn stops.Note that it is not necessary to use the APU SHUT OFFswitch on the EXTERNAL POWER panel in case of APU fireauto extinguishing.
TMUFIR801-T01 LEVEL 3
EFFECTIVITY 26-13-00 Page 2Jul 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 84EFFECTIVITYALL
APU FIRE PROTECTION - AUTO EXTINGUISHING ON GROUNDTMUFIR801-P01 LEVEL 3
EFFECTIVITY 26-13-00 Page 3Jul 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 85EFFECTIVITYALL
THIS PAGE INTENTIONALLY LEFT BLANK
TMUFIR801 LEVEL 3
EFFECTIVITY 26-13-00 Page 4Jul 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 86EFFECTIVITYALL
26 - FIRE PROTECTION
26-13-00 APU FIRE PROTECTION: PRECAUTIONS
CONTENTS:GeneralFire BottleDischarge Cartridge
TMUFIAK01 LEVEL 3
EFFECTIVITY 26-13-00 Page 1May 31/94
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 87EFFECTIVITYALL
APU FIRE PROTECTION: PRECAUTIONS
GENERAL
Specific precautions must be taken during removal orinstallation of a fire extinguishing bottle and adischarge cartridge.
FIRE BOTTLE
WARNING: The fire bottle cartridges are explosive.Remove them before working on the bottle.Protective caps must be installed duringbottle removal/installation to preventdamage to discharge diaphragm which couldresult in injury to personnel.
DISCHARGE CARTRIDGE
WARNING: Before power is supplied to the aircraft makecertain that electrical circuits upon whichwork is in progress are isolated.
WARNING: Cartridges are class "C" explosives and mustbe handled or stored by authorized personnelor disposed of by an approved method.When cartdridge electrical connectors aredisconnected, the cartridge electrical pinsmust be shunted with a protective shunt whichis provided by the manufacturer. A shunt plugor shorting clip, will prevent bottledischarge which could cause injury tomaintenance personnel.The cartridge installed must be of the samemake as the fire bottle and correspond to thespecification indicated in the MaintenanceManual.
TMUFIAK01-T01 LEVEL 3
EFFECTIVITY 26-13-00 Page 2May 31/94
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 88EFFECTIVITYALL
26 - FIRE PROTECTION
26-13-00 APU FIRE PROTECTION: COMPONENTS
CONTENTS:Fire DetectorFire Detection Unit (FDU)Fire BottleRed Disc
TMUFIRK01 LEVEL 3
EFFECTIVITY 26-13-00 Page 1Aug 31/96
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 89EFFECTIVITYALL
APU FIRE PROTECTION: COMPONENTS
SAFETY PRECAUTIONS
WARNING:
Cartridges are explosive, remove them before workingon the bottle. Protective caps must be installed duringbottle removal/installation to prevent damage to thedischarge diaphragm which could result in injury topersonnel.
Before power is spplied to the aircraft make certainthat electrical circuits upon which work is in progressare isolated.Discharge cartridges are class "c" explosives and mustbe handled/stored by authorized personnel or disposedof by an approved method.Wuen cartridge electrical connectors are disconnectedthe cartridge electrical pins must be shunted with aprotective shunt which is provided by the manufacturer.A shunt plug or shorting clip will prevent bottledischarge which could cause injury to maintenancepersonnel.The cartridge installed must be of the same make asthe bottle and correspond to the specificationindicated in the Maintenance Manual.
FIRE DETECTOR
IDENTIFICATIONFIN: 21WG, 22WG
LOCATIONZONE: 316
COMPONENT DESCRIPTIONOne per loop.The detector is pneumatically operated by heating itssensing element which contains helium gas and anhydrogen charged core material.
Alarm StateThe application of heat to the sensor causes anincrease of the gas pressure which in turn closes thealarm switch. The detector sends a FIRE signal.
Fault StateIn the event of gas pressure loss, the integrity switchopens and generates a fault signal.
TMUFIRK01-T01 LEVEL 3
EFFECTIVITY 26-13-00 Page 2Aug 31/96
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 90EFFECTIVITYALL
TMUFIRK01-P01 LEVEL 3
APU FIRE PROTECTION: COMPONENTS
EFFECTIVITY 26-13-00 Page 3Aug 31/96
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 91EFFECTIVITYALL
APU FIRE PROTECTION: COMPONENTS
FIRE DETECTION UNIT (FDU)
IDENTIFICATIONFIN: 13WG
LOCATIONZONE: 126
FIRE BOTTLE
IDENTIFICATIONFIN: 11WF
LOCATIONZONE: 314
COMPONENT DESCRIPTION- Type of agent: bromotrifluoromethane.- Nominal Nitrogen pressure at 21 deg.C: 600 psi.
Pressure SwitchThe pressure switch operates at 225 psi.An allen key can be inserted in the manual test pointin order to check the pressure.The pressure switch is calibrated at:
- 450 psi when the pressure increases(refilling).
- 225/275 psi when the pressure decreases(discharge or leak).
SquibThe squib is an electropyrotechnic cartridgecontaining explosive powder fired by two filamentssupplied with 28 VDC.
WARNING: Never check the continuity of the squib usinga conventional ohmmeter.
TMUFIRK01-T02 LEVEL 3
EFFECTIVITY 26-13-00 Page 4Aug 31/96
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 92EFFECTIVITYALL
TMUFIRK01-P02 LEVEL 3
APU FIRE PROTECTION: COMPONENTS
EFFECTIVITY 26-13-00 Page 5Aug 31/96
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 93EFFECTIVITYALL
APU FIRE PROTECTION: COMPONENTS
RED DISC
Is blown out in case of thermal discharge.
TMUFIRK01-T03 LEVEL 3
EFFECTIVITY 26-13-00 Page 6Aug 31/96
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 94EFFECTIVITYALL
TMUFIRK01-P03 LEVEL 3
APU FIRE PROTECTION: COMPONENTS
EFFECTIVITY 26-13-00 Page 7Aug 31/96
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 95EFFECTIVITYALL
THIS PAGE INTENTIONALLY LEFT BLANK
TMUFIRK01 LEVEL 3
EFFECTIVITY 26-13-00 Page 8Aug 31/96
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 96EFFECTIVITYALL
26 - FIRE PROTECTION
26-13-00 APU FIRE PROTECTION: ELECTRICALCIRCUITS
CONTENTS:DetectionExtinguishingAuto Extinguishing
TMUFIRR01 LEVEL 3
EFFECTIVITY 26-13-00 Page 1May 31/94
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 97EFFECTIVITYALL
TMUFIRR01-P01 LEVEL 3
APU FIRE PROTECTION: ELECTRICAL CIRCUITS - DETECTION
EFFECTIVITY 26-13-00 Page 2May 31/94
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 98EFFECTIVITYALL
APU FIRE PROTECTION: ELECTRICAL CIRCUITS - EXTINGUISHINGTMUFIRR01-P02 LEVEL 3
EFFECTIVITY 26-13-00 Page 3May 31/94
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 99EFFECTIVITYALL
APU FIRE PROTECTION: ELECTRICAL CIRCUITS - APU FIRE PUSHTMUFIRR01-P03 LEVEL 3
EFFECTIVITY 26-13-00 Page 4May 31/94
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 100EFFECTIVITYALL
APU FIRE PROTECTION: ELECTRICAL CIRCUITS - DISCHTMUFIRR01-P04 LEVEL 3
EFFECTIVITY 26-13-00 Page 5May 31/94
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 101EFFECTIVITYALL
APU FIRE PROTECTION: ELECTRICAL CIRCUITS - AUTO EXTINGUISHINGTMUFIRR01-P05 LEVEL 3
EFFECTIVITY 26-13-00 Page 6May 31/94
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 102EFFECTIVITYALL
APU FIRE PROTECTION: ELECTRICAL CIRCUITS - FIRE DETECTIONTMUFIRR01-P06 LEVEL 3
EFFECTIVITY 26-13-00 Page 7May 31/94
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 103EFFECTIVITYALL
APU FIRE PROTECTION: ELECTRICAL CIRCUITS - TESTTMUFIRR01-P07 LEVEL 3
EFFECTIVITY 26-13-00 Page 8May 31/94
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 104EFFECTIVITYALL
APU FIRE PROTECTION: ELECTRICAL CIRCUITS - RESETTMUFIRR01-P08 LEVEL 3
EFFECTIVITY 26-13-00 Page 9May 31/94
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 105EFFECTIVITYALL
THIS PAGE INTENTIONALLY LEFT BLANK
TMUFIRR01 LEVEL 3
EFFECTIVITY 26-13-00 Page 10May 31/94
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 106EFFECTIVITYALL
26 - FIRE PROTECTION
26-15-00 SYSTEM PRESENTATION
CONTENTS:Smoke DetectorAvionic Equipment Ventilation Computer (AEVC)Gen 1 Line P/BBlower and Extract P/BSelf Examination
TMUFIRO01 LEVEL 1
EFFECTIVITY 26-15-00 Page 1Mar 31/94
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 107EFFECTIVITYALL
SYSTEM PRESENTATION
SMOKE DETECTOR
The avionics compartment smoke detection is providedby a smoke detector installed on the air extractionduct of the avionics ventilation system. In case ofsmoke detection, the smoke detector sends signals tothe Flight Warning Computer, the local warnings andthe Avionics Equipment Ventilation Computer. The smokedetector is of the ionization type.
AVIONIC EQUIPMENT VENTILATION COMPUTER (AEVC)
The Avionic Equipment Ventilation Computer controlsthe avionics ventilation system, monitors the smokedetector condition, and allows the detector to betested by the Centralized Fault Display System. TheAvionics Equipment Ventilation Computer (AEVC) checksthe smoke detector when a test is initiated from theCentralized Fault Display Interface Unit (CFDIU).
GEN 1 LINE PUSHBUTTON
The smoke detector activates the GEN 1 LINE SMOKE lighton the EMER ELEC PWR panel.
BLOWER AND EXTRACT PUSHBUTTON
The smoke detector activates the BLOWER FAULT andEXTRACT FAULT lights on the ventilation panel.
TMUFIRO01-T01 LEVEL 1
EFFECTIVITY 26-15-00 Page 2Mar 31/94
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 108EFFECTIVITYALL
SYSTEM PRESENTATIONTMUFIRO01-P01 LEVEL 1
EFFECTIVITY 26-15-00 Page 3Mar 31/94
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 109EFFECTIVITYALL
SELF EXAMINATION
How can the avionics smoke detector be tested?A - Permanently by the AEVC.B - By a dedicated TEST pushbutton.C - By a manual test from the CFDS.
Which warning lights are triggered in case of anavionic smoke detection?
A - GEN 1 LINE SMOKE light.B - BLOWER FAULT.C - GEN 1 LINE SMOKE and BLOWER and EXTRACT
FAULT lights.
TMUFIRO01 LEVEL 1
EFFECTIVITY 26-15-00 Page 4Mar 31/94
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 110EFFECTIVITYALL
26 - FIRE PROTECTION
26-15-00 AVIONICS SMOKE DETECTION:AVIONICS SMOKE PROCEDURE
CONTENTS:Master CautionOxygen MaskCabin and Cockpit IsolationSmoke Source IsolationEssential Electrical Network
TMUFIAC01 LEVEL 3
EFFECTIVITY 26-15-00 Page 1Aug 31/96
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 111EFFECTIVITYALL
AVIONICS SMOKE DETECTION: AVIONICS SMOKE PROCEDURE
MASTER CAUTION
When a smoke is detected the MASTER CAUTION comes on,the single chime sounds, GEN 1 SMOKE light comes onon the emergency electrical power panel and the BLOWERfault and EXTRACT fault lights on the ventilation panelcome on.The actions to be performed appear on the upper ECAMdisplay.Note that the smoke is directly perceptible by thecrew through the center pedestal.
- Select the MASTER CAUTION before performingECAM actions.
OXYGEN MASK
As smoke is confirmed, use the OXYGEN MASKS andestablish crew communication.
- Select the OXYGEN MASK.
CABIN AND COCKPIT ISOLATION
CABIN FANSAvoid the use of interphone position to minimize theinterference from oxygen mask breathing noise.Stop the cabin fans to prevent smoke from enteringinto the cockpit and cabin.
- Set CAB FANS pushbutton to OFF.When it is set to off, the cabin FANS stop.
BLOWER FAN
The blower and extract fans of the avionics ventilationsystem must be set to the override position, toevacuate the smoke overboard.
- Set the BLOWER pushbutton to OVRD position.When the BLOWER pushbutton is set to override, theblower fan stops and the air conditioning system isused as a cold air source.
EXTRACT FAN- Set the EXTRACT pushbutton to OVRD position.
EXTRACT VALVEWhen the EXTRACT pushbutton is set to override, theair is extracted overboard through the extract valvewhich is partially open. The extract fan continues torun.
TMUFIAC01-T01 LEVEL 3
EFFECTIVITY 26-15-00 Page 2Aug 31/96
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 112EFFECTIVITYALL
TMUFIAC01-P01 LEVEL 3
AVIONICS SMOKE DETECTION: AVIONICS SMOKE PROCEDUREMASTER CAUTION - OXYGEN MASK - CABIN AND COCKPIT ISOLATION
EFFECTIVITY 26-15-00 Page 3Aug 31/96
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 113EFFECTIVITYALL
AVIONICS SMOKE DETECTION: AVIONICS SMOKE PROCEDURE
SMOKE SOURCE ISOLATION
GENERATOR 1As smoke is still perceptible, it is necessary to acton the electrical system. The following actions allowthe normal electrical network to be shed to isolatethe smoke source.
- Set GEN 1 LINE pushbutton to OFF position.
TMUFIAC01-T02 LEVEL 3
EFFECTIVITY 26-15-00 Page 4Aug 31/96
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 114EFFECTIVITYALL
AVIONICS SMOKE DETECTION: AVIONICS SMOKE PROCEDURESMOKE SOURCE ISOLATION
TMUFIAC01-P02 LEVEL 3
EFFECTIVITY 26-15-00 Page 5Aug 31/96
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 115EFFECTIVITYALL
AVIONICS SMOKE DETECTION: AVIONICS SMOKE PROCEDURE
RAM AIR TURBINEAction on the GEN 1 LINE pushbutton opens the generator1 line contactor. Generator 1 continues to supply onefuel pump on each wing tank, and the galleys are shed.AC BUS 1 is supplied by generator 2 through the bustie contactor.
- Select the MAN ON pushbutton to extend theRam Air Turbine.
TMUFIAC01-T03 LEVEL 3
EFFECTIVITY 26-15-00 Page 6Aug 31/96
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 116EFFECTIVITYALL
AVIONICS SMOKE DETECTION: AVIONICS SMOKE PROCEDURESMOKE SOURCE ISOLATIONT
MUFIAC01-P03 LEVEL 3
EFFECTIVITY 26-15-00 Page 7Aug 31/96
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 117EFFECTIVITYALL
AVIONICS SMOKE DETECTION: AVIONICS SMOKE PROCEDURE
ESSENTIAL ELECTRICAL NETWORK
SUPPLYThe Ram Air Turbine is now extended and the emergencygenerator is connected to keep the aircraft essentialelectrical network supplied.Notice that the emergency generator parameters aredisplayed on the ECAM.
GENERATOR 2With the emergency generator running, the engine 2 andAPU generators have to be switched off in order toisolate the normal electrical network. Enginegenerator 1 must be kept running for fuel pumpoperation.
- Set GEN 2 pushbutton to OFF.
TMUFIAC01-T04 LEVEL 3
EFFECTIVITY 26-15-00 Page 8Aug 31/96
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 118EFFECTIVITYALL
AVIONICS SMOKE DETECTION: AVIONICS SMOKE PROCEDURESMOKE SOURCE ISOLATIONT
MUFIAC01-P04 LEVEL 3
EFFECTIVITY 26-15-00 Page 9Aug 31/96
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 119EFFECTIVITYALL
AVIONICS SMOKE DETECTION: AVIONICS SMOKE PROCEDURE
EMERGENCY CONFIGURATIONAs both engine generators have been disconnected, theelectrical system is now in emergency configurationand the lower ECAM display is no longer supplied.Land as soon as possible observing the emergencyprocedure.The avionics smoke procedure has now been completed.
TMUFIAC01-T05 LEVEL 3
EFFECTIVITY 26-15-00 Page 10Aug 31/96
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 120EFFECTIVITYALL
AVIONICS SMOKE DETECTION: AVIONICS SMOKE PROCEDUREESSENTIAL ELECTRICAL NETWORKT
MUFIAC01-P05 LEVEL 3
EFFECTIVITY 26-15-00 Page 11Aug 31/96
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 121EFFECTIVITYALL
THIS PAGE INTENTIONALLY LEFT BLANK
TMUFIAC01 LEVEL 3
EFFECTIVITY 26-15-00 Page 12Aug 31/96
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 122EFFECTIVITYALL
26 - FIRE PROTECTION
26-15-00 AVIONICS SMOKE DETECTION:COMPONENTS
CONTENTS:Smoke Detector
TMUFIRP01 LEVEL 3
EFFECTIVITY 26-15-00 Page 1Apr 30/96
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 123EFFECTIVITYALL
AVIONICS SMOKE DETECTION: COMPONENTS
SMOKE DETECTOR
IDENTIFICATIONFIN: 1WA
LOCATIONZONE:128
IONIZATION PRINCIPLE
COMPONENT DESCRIPTIONThe smoke detector is based on the ionizationprinciple.It ionizes the air particles that pass between theelectrodes. As smoke causes the electrical resistanceof the circuit to increase, the voltage in themeasurement chamber increases to a higher level thanthe reference chamber and at a set difference level,the detector sends a signal to the AEVC.
TMUFIRP01-T01 LEVEL 3
EFFECTIVITY 26-15-00 Page 2Apr 30/96
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 124EFFECTIVITYALL
AVIONICS SMOKE DETECTION: COMPONENTS
TMUFIRP01-P01 LEVEL 3
EFFECTIVITY 26-15-00 Page 3Apr 30/96
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 125EFFECTIVITYALL
THIS PAGE INTENTIONALLY LEFT BLANK
TMUFIRP01 LEVEL 3
EFFECTIVITY 26-15-00 Page 4Apr 30/96
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 126EFFECTIVITYALL
26 - FIRE PROTECTION
26-17-00 CARGO FIRE PROTECTION SYSTEMPRESENTATION
CONTENTS:GeneralSmoke DetectorsSmoke Detection Control Unit (SDCU)WarningsDisch PushbuttonBottleTest PushbuttonSelf Examination
TMUFIRZ01 LEVEL 1
EFFECTIVITY 26-17-00 Page 1Aug 31/98
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 127EFFECTIVITYALL
CARGO FIRE PROTECTION SYSTEM PRESENTATION
GENERAL
The cargo fire protection is provided by two systems:- The cargo smoke detection (separate FWD & AFToptional systems)
- The cargo fire extinguishing (separate FWD &AFT optional systems)
Note that the fire extinguishing system requires thesmoke detection system.
SMOKE DETECTORS
The cargo smoke detection system is installed in theFWD and in the AFT/BULK cargo compartments. Four smokedetectors are located in two cavities in the ceilingof the AFT/BULK cargo compartment and two othersdetectors in the FWD cargo compartment. The cargo smokedetectors are interconnected to each other. They arepart of a loop, containing the lavatory smokedetectors, which is connected to the Smoke DetectionControl Unit (SDCU).
SMOKE DETECTION CONTROL UNIT
For each compartment, the Smoke Detection Control Unit(SDCU) activates the warning with an AND logic toprevent false warnings. The SDCU also monitors thesmoke detectors in case of a single detection. Whenonly one cargo smoke detector detects smoke, the SDCUchecks the second detector automatically.
- If this test shows a normal operation of thesecond detector, the first detector is declaredfaulty. The result is no SMOKE warning in thecockpit.
- If this test shows an abnormal operation ofthe second detector, the SMOKE warnings areactivated. The second detector is declaredfaulty.
WARNINGS
The Smoke Detection Control Unit generates signals forcockpit local warnings, ECAM system and CargoVentilation Controller. It also provides the faultmessages to the Centralized Fault Display System(CFDS). In case of FWD or AFT/BULK smoke detection,the respective SMOKE light comes on on the CARGO SMOKEpanel. At the same time the CARGO VENTILATIONCONTROLLER closes the isolation valves of the affectedcompartment (If ventilation installed).In case of a smoke detector failure, the SDCU sendssignals to the ECAM and CFDS systems.
DISCH PUSHBUTTON
Action on one of the FWD or AFT guarded DISCHchargepushbuttons discharges the bottle in the respectivecargo compartment. When smoke is detected, the corresponding DISCHpushbutton has to be pressed, in order to fire therelative squib of the extinguishing bottle. Both DISCHlights come on when the fire extinguishing bottle isdischarged. Both DISCH lights come on when the fireextinguishing bottle is discharged.
TMUFIRZ01-T01 LEVEL 1
EFFECTIVITY 26-17-00 Page 2Aug 31/98
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 128EFFECTIVITYALL
CARGO FIRE PROTECTION SYSTEM PRESENTATIONTMUFIRZ01-P01 LEVEL 1
EFFECTIVITY 26-17-00 Page 3Aug 31/98
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 129EFFECTIVITYALL
CARGO FIRE PROTECTION SYSTEM PRESENTATION
BOTTLE
One extinguisher bottle is installed in the Forwardcargo compartment and provides fire extinguishing forthe FWD and for the AFT/BULK cargo compartment. Thebottle is equipped with a pressure switch to monitoragent pressure and two electrically firing cartridgesor squibs for agent discharges. The bottle pressureand the two squibs circuit conditions are continuouslymonitored by the SDCU. In case of bottle pressure dropor loss of electrical squib continuity, the SDCU sendssignals to the ECAM and CFDS.
TEST PUSHBUTTON
When the TEST pushbutton is pressed and held, the SCDUcarries out an automatic test. Smoke and a bottlepressure drop conditions are simulated. The smokedetectors are tested. When the TEST pushbutton ispressed and held, the SMOKE and DISCH lights on theCARGO SMOKE panel come on, and the ECAM warnings areactivated. When the TEST pushbutton is released, theDISCH lights go off, with a time delay of 2 seconds,and the SMOKE lights go off, with a time delay of 10seconds. The ECAM message disappears and will beautomatically repeated with the warning indicationsfor approximately 6 seconds.
TMUFIRZ01-T01 LEVEL 1
EFFECTIVITY 26-17-00 Page 4Aug 31/98
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 130EFFECTIVITYALL
SELF EXAMINATION
How are the cargo smoke detectors connected to theSDCU ?
A - In parallel.B - In series.C - In a loop.
How many smoke detectors are installed in the cargocompartments?
A - Three.B - Eight.C - Six.
When the TEST pushbutton is pressed and held, whichconditions are simulated?
A - Smoke only.B - Bottle pressure drop only.C - Both.
TMUFIRZ01 LEVEL 1
EFFECTIVITY 26-17-00 Page 5Aug 31/98
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 131EFFECTIVITYALL
THIS PAGE INTENTIONALLY LEFT BLANK
TMUFIRZ01 LEVEL 1
EFFECTIVITY 26-17-00 Page 6Aug 31/98
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 132EFFECTIVITYALL
26 - FIRE PROTECTION
26-17-00 LAVATORY FIRE PROTECTION SYSTEMPRESENTATION
CONTENTS:Smoke DetectorsSmoke Detection Control Unit (SDCU)Smoke WarningsSelf Examination
TMUFIRL02 LEVEL 1
EFFECTIVITY 26-17-00 Page 1Jun 30/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 133EFFECTIVITYALL
LAVATORY FIRE PROTECTION SYSTEM PRESENTATION
SMOKE DETECTORS
An ambient smoke detector is installed on eachlavatory, located in the ceiling panel, beside the airextraction duct. The lavatory smoke detectors areinterconnected to each other. They are part of a loop,containing the cargo smoke detectors (if cargo smokedetection is installed), which is connected to theSmoke Detection Control Unit (SDCU).The smoke detector is a photo-electric cell smokedetector based on the principle of reverse scatteredlight.
SMOKE DETECTION CONTROL UNIT
In case of a detected lavatory smoke, the SmokeDetection Control Unit (SDCU) activates the smokewarnings in the cockpit and the passenger cabin. TheSmoke Detection Control Unit (SDCU) monitors all thelavatory smoke detectors.
SMOKE WARNINGS
The Smoke Detection Control Unit sends the lavatorysmoke warning signals to the ECAM and CabinIntercommunication Data System (CIDS). It alsoprovides the fault messages to the Centralized FaultDisplay System (CFDS). An option disables lavatorywarnings on the ECAM. Note that for lavatory fireextinguishing, a cabin portable fire extinguisher mustbe used.
TMUFIRL02-T01 LEVEL 1
EFFECTIVITY 26-17-00 Page 2Jun 30/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 134EFFECTIVITYALL
TMUFIRL02-P01 LEVEL 1
LAVATORY FIRE PROTECTION SYSTEM PRESENTATION
EFFECTIVITY 26-17-00 Page 3Jun 30/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 135EFFECTIVITYALL
SELF EXAMINATION
Lavatory fire extinguishing is performed by:A - Portable extinguisher.B - Fire bottle.C - Waste bin fire extinguisher.
TMUFIRL02 LEVEL 1
EFFECTIVITY 26-17-00 Page 4Jun 30/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 136EFFECTIVITYALL
26 - FIRE PROTECTION
26-16-00 CARGO AND LAVATORY SMOKEDETECTION SYSTEM
CONTENTS:GeneralLavatory SmokeLavatory FaultCargo Smoke (Option)Cargo Fault (Option)Bottle FaultSmoke Detection Control Unit (SDCU) FaultSelf Examination
TMUFIRY01 LEVEL 3
EFFECTIVITY 26-16-00 Page 1Aug 31/98
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 137EFFECTIVITYALL
CARGO AND LAVATORY SMOKE DETECTION SYSTEM
GENERAL
The cargo and lavatory smoke detectors are connectedto both channels of the Smoke Detection Control Unit(SDCU) via a safety two wire data and supply bus workingfollowing the closed loop principle.Note that the cargo fire protection is optional andindependent for each compartment but cargo fireextinguishing requires smoke detection.
LAVATORY SMOKE
When lavatory smoke is detected, the Smoke DetectionControl Unit (SDCU) provides the SMOKE warning signalto the cockpit and to the cabin.When smoke is detected in a lavatory, the followingwarnings are activated:
- In the cockpit, through the Flight WarningComputers (FWCs), the repetitive chime, theMASTER WARN flashing light and ECAM message.Note that an option disables all lavatorywarnings in the cockpit.
- In the cabin, through the CabinIntercommunication Data System (CIDS)directors, the triple chime, the SMOKE LAVlight on the Forward Attendant Panel, the redflashing light and clear message on theAttendant Indication Panel, the amber flashinglight on the Area Call Panel and an amberflashing light on the affected lavatory.
LAVATORY FAULT
When a lavatory smoke detector failure is detected bythe SDCU, the faulty detector is automatically isolatedfrom the loop.The lavatory detection fault is indicated in thecockpit and the cabin.The inoperative lavatory smoke detector is indicatedto:
- The CFDIU, for maintenance purposes.- The FWC, for ECAM indication.- The CIDS directors, for the Forward AttendantPanel amber CIDS CAUT light and the Programmingand Test Panel (PTP) indication.
NOTE: With CIDS CAUT light ON, the CIDS SYSTEM STATUSpage on the PTP must be interrogated to find theaffected lavatory.
TMUFIRY01-T01 LEVEL 3
EFFECTIVITY 26-16-00 Page 2Aug 31/98
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 138EFFECTIVITYALL
CARGO AND LAVATORY SMOKE DETECTION SYSTEMTMUFIRY01-P01 LEVEL 3
EFFECTIVITY 26-16-00 Page 3Aug 31/98
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 139EFFECTIVITYALL
CARGO AND LAVATORY SMOKE DETECTION SYSTEM
CARGO SMOKE
When cargo smoke is detected, the SDCU provides theSMOKE warning signal to the cockpit through the FlightWarning Computers (FWC).When smoke is detected in one compartment, (AFT shownas example), the following warnings are activated:
- The repetitive chime, the MASTER WARN light,the ECAM message and the SMOKE light on theCARGO SMOKE panel.
CARGO FAULT
When a cargo smoke detector is detected faulty by theSDCU, it is automatically isolated from the loop.When the two detectors of the same cavity are detectedfaulty, a cargo smoke detection fault message isdisplayed on the ECAM.The inoperative detectors (BULK shown as example) arealso indicated to the CFDIU.
BOTTLE FAULT
In case of a fire bottle pressure drop or a loss ofelectrical squib continuity, the SDCU sends signalsto the ECAM and CFDS.When a discontinuity occurs on the squib circuit, thefollowing warning is activated by the FWCs:
- Single chime, MASTER CAUT light and ECAMmessage.
The inoperative squib is also indicated to the CFDIU.
SMOKE DETECTION CONTROL UNIT (SDCU) FAULT
When an internal failure of the SDCU is detected, aSDCU fault warning signal is sent to the cockpit.In case of failure of one channel, the smoke detectionis still ensured by the remaining channel.In case of failure of both channels, the fault isdisplayed on the ECAM, accompanied by the single chimeand MASTER CAUT light. The failure is also indicatedto the CFDIU.
TMUFIRY01-T01 LEVEL 3
EFFECTIVITY 26-16-00 Page 4Aug 31/98
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 140EFFECTIVITYALL
SELF EXAMINATION
If smoke is detected in a cargo compartment whathappens?
A - SMOKE light comes on + ContinuousRepetitive Chime + MASTER WARNING + ECAMmessage.
B - The CIDS duplicates the cargo smokewarning to the cabin.
C - lights come on.
What happens if the SDCU is faulty?A - The lavatory smoke detection is
inoperative.B - The cargo smoke detection is inoperativeC - Both A and B, with Single Chime + MASTER
CAUT + ECAM message.
TMUFIRY01 LEVEL 3
EFFECTIVITY 26-16-00 Page 5Aug 31/98
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 141EFFECTIVITYALL
THIS PAGE INTENTIONALLY LEFT BLANK
TMUFIRY01 LEVEL 3
EFFECTIVITY 26-16-00 Page 6Aug 31/98
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 142EFFECTIVITYALL
26 - FIRE PROTECTION
26-16-00 CARGO AND LAVATORY FIREPROTECTION - CARGO SMOKEDETECTION WARNING
CONTENTS:Cargo Smoke Detection
TMUFIAD04 LEVEL 3
EFFECTIVITY 26-16-00 Page 1Jun 30/96
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 143EFFECTIVITYALL
CARGO SMOKE DETECTION WARNING
CARGO SMOKE DETECTION
When cargo smoke is detected, the SMOKE light comeson on the CARGO SMOKE panel and the ISOLation VALVEFAULT light on the CARGO HEAT panel comes on. Thecontinuous repetitive chime sounds, the MASTER WARNINGflashes and the AIR conditioning page appears with thesmoke message on the ECAM.Note that the FWD & AFT ventilation and heating systemsare optional.On A320 and A319 only:The FWD & AFT cargo fire protection systems areoptional and independent.The cargo fire extinguishing option requires the cargosmoke detection option.
TMUFIAD04-T01 LEVEL 3
EFFECTIVITY 26-16-00 Page 2Jun 30/96
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 144EFFECTIVITYALL
CARGO SMOKE DETECTION WARNINGTMUFIAD04-P01 LEVEL 3
EFFECTIVITY 26-16-00 Page 3Jun 30/96
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 145EFFECTIVITYALL
THIS PAGE INTENTIONALLY LEFT BLANK
TMUFIAD04 LEVEL 3
EFFECTIVITY 26-16-00 Page 4Jun 30/96
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 146EFFECTIVITYALL
26 - FIRE PROTECTION
26-16-00 CARGO SMOKE PROCEDURE
CONTENTS:Cargo Smoke Procedure
TMUFIAE01 LEVEL 3
EFFECTIVITY 26-16-00 Page 1Jun 30/96
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 147EFFECTIVITYALL
CARGO SMOKE PROCEDURE
CARGO SMOKE PROCEDURE
Note that the ventilation, the heating and the smokeprotection systems are optional and independent foreach compartment.When cargo smoke is detected (bulk smoke is shown asan example), the continuous repetitive chime sounds,the MASTER WARN flashes and the SMOKE light on theCARGO SMOKE panel comes on.The isolation valves of the cargo compartment areautomatically closed and the ISOL VALVE FAULT lighton the CARGO HEAT panel comes on.
- Select the AFT ISOL VALVE pushbutton.(Available only if AFT ventilation system isinstalled)
When the AFT ISOL VALVE pushbutton is set to OFF, theisolation valves closure is confirmed.
- Select the DISCH pusbutton for the AFT cargocompartment.
When the DISCH pushbutton is pressed, the fire bottleis discharged into the cargo compartment. As the bottlepressure is released, the pressure switch provides theDISCH light activation.
With the smoke extinguished, all warnings disappearexcept the DISCH lights which remains illuminated.For information, note that in case of cargo smokewarning on ground you should never discharge theon-board extinguishing bottle. Make a visualinspection of the cargo compartment and use portableextinguishers if fire is confirmed.T
MUFIAE01-T01 LEVEL 3
EFFECTIVITY 26-16-00 Page 2Jun 30/96
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 148EFFECTIVITYALL
CARGO AND LAVATORY FIRE PROTECTION - CARGO SMOKE PROCEDURETMUFIAE01-P01 LEVEL 3
EFFECTIVITY 26-16-00 Page 3Jun 30/96
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 149EFFECTIVITYALL
THIS PAGE INTENTIONALLY LEFT BLANK
TMUFIAE01 LEVEL 3
EFFECTIVITY 26-16-00 Page 4Jun 30/96
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 150EFFECTIVITYALL
26 - FIRE PROTECTION
26-16-00 CARGO AND LAVATORY FIREPROTECTION - LAVATORY SMOKEDETECTION WARNINGS
CONTENTS:Lavatory Smoke Warnings
TMUFIAF19 LEVEL 3
EFFECTIVITY 26-16-00 Page 1Jan 31/96
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 151EFFECTIVITYALL
CARGO AND LAVATORY FIRE PROTECTION - LAVATORY SMOKE DETECTION WARNINGS
LAVATORY SMOKE WARNINGS
When lavatory smoke is detected the alarms aretransmitted to the cockpit and the cabin.In the cockpit, the Continuous Repetitive Chime sounds,the MASTER WARNING flashes and a message appears onthe engine warning display.Note that an option disables lavatory warnings in thecockpit.In the cabin, the continuous high-low chime sounds inall attendant loudspeakers and the red SMOKE LAV P/Blight on the Forward Attendant Panel flashes. The redlight on all Attendant Indication Panels flashes andthe affected lavatory is shown in clear wording.An amber light flashes on all area call panels. Theamber lavatory indicator light, installed outside onthe lavatory wall, flashes. Note that the lavatorysmoke warnings stop, when the smoke concentration dropsbelow the threshold of the smoke detector. Warning canalso be stopped through the related RESET pushbuttons.
TMUFIAF19-T01 LEVEL 3
EFFECTIVITY 26-16-00 Page 2Jan 31/96
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 152EFFECTIVITYALL
CARGO AND LAVATORY FIRE PROTECTION - LAVATORY SMOKE DETECTION WARNINGSTMUFIAF19-P01 LEVEL 3
EFFECTIVITY 26-16-00 Page 3Jan 31/96
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 153EFFECTIVITYALL
THIS PAGE INTENTIONALLY LEFT BLANK
TMUFIAF19 LEVEL 3
EFFECTIVITY 26-16-00 Page 4Jan 31/96
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 154EFFECTIVITYALL
26 - FIRE PROTECTION
26-20-00 CARGO AND LAVATORY FIREPROTECTION: LAVATORY WASTE BINFIRE EXTINGUISHING SYSTEMPRESENTATION
CONTENTS:Waste Bin Fire Extinguisher
TMUFIAW01 LEVEL 3
EFFECTIVITY 26-20-00 Page 1Jun 30/96
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 155EFFECTIVITYALL
CARGO AND LAVATORY FIRE PROTECTION: LAVATORY WASTE BIN FIRE EXTINGUISHING SYSTEMPRESENTATION
WASTE BIN FIRE EXTINGUISHER
In each lavatory is provided a waste bin fireextinguisher.As any fire in the waste is kept within confines ofthe metal waste bin, a small fire extinguisher is builtin the waste bin of each lavatory to provide automaticextinguishing in case of fire.The waste bin fire extinguishing system automaticallydischarges its agent when overheating melts a fusiblematerial in the tip of the discharge tube.
TMUFIAW01-T01 LEVEL 3
EFFECTIVITY 26-20-00 Page 2Jun 30/96
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 156EFFECTIVITYALL
CARGO AND LAVATORY FIRE PROTECTION: LAVATORY WASTE BIN FIRE EXTINGUISHING SYSTEMPRESENTATION
TMUFIAW01-P01 LEVEL 3
EFFECTIVITY 26-20-00 Page 3Jun 30/96
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 157EFFECTIVITYALL
THIS PAGE INTENTIONALLY LEFT BLANK
TMUFIAW01 LEVEL 3
EFFECTIVITY 26-20-00 Page 4Jun 30/96
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 158EFFECTIVITYALL
26 - FIRE PROTECTION
26-17-00 PROGRAMMING AND TEST PANELUTILIZATION
CONTENTS:System StatusLAV Smoke Sys FailSystem Status (Next Page)Maintenance
TMUFIAG01 LEVEL 3
EFFECTIVITY 26-17-00 Page 1Aug 31/94
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 159EFFECTIVITYALL
PROGRAMMING AND TEST PANEL UTILIZATION
SYSTEM STATUS (1)
The SYSTEM STATUS page presents the current status ofthe CIDS and for maintenance, additional informationabout the status of the systems also monitored by theCIDS.In our example, a failure has been detected in thelavatory smoke detection system.
LAV SMOKE SYS FAIL (2)
This page indicates that the SMOKE DETector of theLAVatory A is faulty.
SYSTEM STATUS (NEXT PAGE) (3)
This is the next page of the SYSTEM STATUS, otherinformation is available for maintenance purpose.
MAINTENANCE (3.1 - 3.1.1)
The maintenance page allows further information to beobtained from:
- LAST LEG REPORT- PREV LEG REPORT- LRU IDENTIFICATION- FAULT DATA- CLASS 3 FAULT
NOTE: Selection of FAULT DATA gives coded troubleshooting data for internal director and DecoderEncoder Unit (DEU) failures.
TMUFIAG01-T01 LEVEL 3
EFFECTIVITY 26-17-00 Page 2Aug 31/94
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 160EFFECTIVITYALL
TMUFIAG01-P01 LEVEL 3
PROGRAMMING AND TEST PANEL UTILIZATION
EFFECTIVITY 26-17-00 Page 3Aug 31/94
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 161EFFECTIVITYALL
THIS PAGE INTENTIONALLY LEFT BLANK
TMUFIAG01 LEVEL 3
EFFECTIVITY 26-17-00 Page 4Aug 31/94
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 162EFFECTIVITYALL
26 - FIRE PROTECTION
26-16-00 CARGO AND LAVATORY FIREPROTECTION: PRECAUTIONS
CONTENTS:GeneralFire BottleDischarge Cartridge
TMUFIRD02 LEVEL 3
EFFECTIVITY 26-16-00 Page 1Jun 30/96
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 163EFFECTIVITYALL
CARGO AND LAVATORY FIRE PROTECTION: PRECAUTIONS
GENERAL
Specific precautions must be taken during removal orinstallation of a fire extinguishing bottle and adischarge cartridge.Note that the fire extinguishing system is optional(A320 and A319 only).
FIRE BOTTLE
WARNING: The fire bottle cartridges are explosive.Remove them before working on the bottle.Protective caps must be installed duringbottle removal/installation to preventdamage to discharge diaphragm which couldresult in injury to personnel.
DISCHARGE CARTRIDGE
WARNING: Before power is supplied to the aircraft makecertain that electrical circuits upon whichwork is in progress are isolated.
WARNING: Cartridges are class "C" explosives and mustbe handled or stored by authorized personnelor disposed of by an approved method.When cartridge electrical connectors aredisconnected, the cartridge electrical pinsmust be shunted with a protective shunt whichis provided by the manufacturer. A shunt plugor shorting clip, will prevent bottledischarge which could cause injury tomaintenance personnel.The cartridge installed must be of the samemake as the fire bottle and correspond to thespecification indicated in the MaintenanceManual.
TMUFIRD02-T01 LEVEL 3
EFFECTIVITY 26-16-00 Page 2Jun 30/96
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 164EFFECTIVITYALL
26 - FIRE PROTECTION
26-16-00 CARGO AND LAVATORY FIREPROTECTION - COMPONENTS
CONTENTS:Lavatory Smoke DetectorsCargo Smoke DetectorsSmoke Detection Control Unit (SDCU)Cargo Fire BottleExtinguishing NozzlesWaste Bin Extinguisher
TMUFIRX03 LEVEL 3
EFFECTIVITY 26-16-00 Page 1Aug 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 165EFFECTIVITYALL
CARGO AND LAVATORY FIRE PROTECTION - COMPONENTS
SAFETY PROTECTION
GENERALSpecific precautions must be taken during removal orinstallation of a fire extinguishing bottle and adischarge cartridge.
FIRE BOTTLE
WARNING: The fire bottle cartridges are explosive,remove them before working on the bottle.Protective caps must be installed duringbottle removal/installation to preventdamage to the discharge diaphragm which couldresult in injury to personnel.
DISCHARGE CARTRIDGE
WARNING: Before power is supplied to the aircraft makecertain that electrical circuits upon whichwork is in progress are isolated.
WARNING: Discharge cartridges are class "C" explosiveswhich must be handled/stored by authorizedpersonnel or disposed of by an approvedmethod.When cartridge electrical connectors aredisconnected, the cartridge electrical pinsmust be shunted with a protective shunt whichis provided by the manufacturer. A shunt plugor shorting clip will prevent bottledischarge which could cause injury tomaintenance personnel.The cartridge installed must be of the samemake as the fire bottle and correspond to thespecification indicated in the MaintenanceManual.
TMUFIRX03-T01 LEVEL 3
EFFECTIVITY 26-16-00 Page 2Aug 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 166EFFECTIVITYALL
THIS PAGE INTENTIONALLY LEFT BLANK
TMUFIRX03 LEVEL 3
EFFECTIVITY 26-16-00 Page 3Aug 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 167EFFECTIVITYALL
CARGO AND LAVATORY FIRE PROTECTION - COMPONENTS
LAVATORY SMOKE DETECTORS (26-17-00)
IDENTIFICATIONFIN: 1WQ, 4WQ, 5WQ
LOCATIONSFWD LAVATORY A, ZONE 221,AFT LAVATORY D, ZONE 261,AFT LAVATORY E, ZONE 261
COMPONENT DESCRIPTIONThe smoke detector operates on the principle of reversescattered light.
SMOKE DETECTORThe light source, the labyrinth and the photocell arearranged in a horizontal plane so that the photocellcannot receive light.But when there is smoke, the smoke particles reflectand diffuse part of the light beam.The photocell receives this light and gives an analogsignal and triggers the alarms.
TMUFIRX03-T02 LEVEL 3
EFFECTIVITY 26-16-00 Page 4Aug 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 168EFFECTIVITYALL
CARGO AND LAVATORY FIRE PROTECTION - COMPONENTS - LAVATORY SMOKE DETECTORSTMUFIRX03-P02 LEVEL 3
EFFECTIVITY 26-16-00 Page 5Aug 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 169EFFECTIVITYALL
CARGO AND LAVATORY FIRE PROTECTION - COMPONENTS
CARGO SMOKE DETECTORS
IDENTIFICATIONFIN: 1WH, 2WH, 3WH, 4WH, 5WH, 6WH
LOCATIONSFWD CARGO COMPARTMENT, ZONE 132,AFT CARGO COMPARTMENT, ZONE 151,BULK CARGO COMPARTMENT, ZONE 161
COMPONENT DESCRIPTIONRefer to lavatory smoke detection components.Note that the cargo smoke detection system is optionaland independent for each compartment.
TMUFIRX03-T03 LEVEL 3
EFFECTIVITY 26-16-00 Page 6Aug 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 170EFFECTIVITYALL
CARGO AND LAVATORY FIRE PROTECTION - COMPONENTS - CARGO SMOKE DETECTORSTMUFIRX03-P03 LEVEL 3
EFFECTIVITY 26-16-00 Page 7Aug 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 171EFFECTIVITYALL
CARGO AND LAVATORY FIRE PROTECTION - COMPONENTS
SMOKE DETECTION CONTROL UNIT (SDCU)
IDENTIFICATIONFIN: 10WQ
LOCATIONZONE: 122, RACK 94VU
COMPONENT DESCRIPTIONThe SDCU has two channels, which make it a fail-safeunit. The system will operate normally if one channelfails. The Built In Test Equipment (BITE) detects andisolates failures in the SCDU. It also makes sure thatthe smoke detectors operate correctly. Most of thesystem functions are monitored continuously.
TMUFIRX03-T04 LEVEL 3
EFFECTIVITY 26-16-00 Page 8Aug 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 172EFFECTIVITYALL
CARGO AND LAVATORY FIRE PROTECTION - COMPONENTS - SMOKE DETECTION CONTROL UNIT (SDCU)TMUFIRX03-P04 LEVEL 3
EFFECTIVITY 26-16-00 Page 9Aug 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 173EFFECTIVITYALL
CARGO AND LAVATORY FIRE PROTECTION - COMPONENTS
CARGO FIRE BOTTLE (26-23-00)
IDENTIFICATIONFIN: 4005WX
LOCATIONFWD CARGO COMPARTMENT, ZONE 132
COMPONENT DESCRIPTIONThe fire extinguisher bottle is made of stainless steeland is hermetically sealed. Fully charged, it weighs15,65 kg. The bottle has two discharge outlets.The extinguishing agent used is halon 1301, which isnontoxic.Each bottle has a pressure switch and a fill and safetyrelief port:
- The pressure switch sends a signal to the SDCUif there is not sufficient pressure in thebottle (if the bottle is discharged or if aleak occurs).
EXTINGUISHING NOZZLES
IDENTIFICATIONThe cargo fire bottle has no FIN
LOCATIONZONE : 132, 151, 161
COMPONENT DESCRIPTIONThe fire extinguishing bottle is connected to theextinguishing nozzles through pipes. One fireextinguisher pipe connects the bottle with the two FWDdischarge nozzles and one pipe with the three nozzlesin the AFT cargo compartment. The nozzles are installedin the cargo compartment smoke detector cavities.Note that the cargo fire extinguishing system isoptional, independent for each compartment andrequires the smoke detection system.
TMUFIRX03-T05 LEVEL 3
EFFECTIVITY 26-16-00 Page 10Aug 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 174EFFECTIVITYALL
CARGO AND LAVATORY FIRE PROTECTION - COMPONENTS - CARGO FIRE BOTTLE - EXTINGUISHINGNOZZLES
TMUFIRX03-P05 LEVEL 3
EFFECTIVITY 26-16-00 Page 11Aug 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 175EFFECTIVITYALL
CARGO AND LAVATORY FIRE PROTECTION - COMPONENTS
WASTE BIN EXTINGUISHER (26-25-00)
IDENTIFICATIONThe waste bin extinguishers have no FIN
LOCATIONSFWD LAVATORY A, ZONE 221AFT LAVATORY D, ZONE 261AFT LAVATORY E, ZONE 261
COMPONENT DESCRIPTIONThe lavatory fire extinguisher bottle is installed aboveeach lavatory waste bin and it’s a complety automatic anda self contained system.At a temperature of approx. 79 °C (174°F) of the wastebin area, it opens the release mecanism.It is charged with between 100 and 130 g of halon 1301,which is nontoxic.
TMUFIRX03-T06 LEVEL 3
EFFECTIVITY 26-16-00 Page 12Aug 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 176EFFECTIVITYALL
CARGO AND LAVATORY FIRE PROTECTION - COMPONENTS - WASTE BIN EXTINGUISHERTMUFIRX03-P06 LEVEL 3
EFFECTIVITY 26-16-00 Page 13Aug 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 177EFFECTIVITYALL
THIS PAGE INTENTIONALLY LEFT BLANK
TMUFIRX03 LEVEL 3
EFFECTIVITY 26-16-00 Page 14Aug 31/00
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 178EFFECTIVITYALL
26 - FIRE PROTECTION
26-24-00 PORTABLE FIRE EXTINGUISHERS
CONTENTS:LocationDescriptionUtilization
TMUFIRM16 LEVEL 1
EFFECTIVITY 26-24-00 Page 1Mar 31/94
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 179EFFECTIVITYALL
PORTABLE FIRE EXTINGUISHERS
LOCATION
Portable fire extinguishers are located in the cabinand in the cockpit. For the cabin, portable fireextinguishers are fitted under the forward and the aftattendant seats. They have to be used to fight firein the cabin and also in the lavatories.
DESCRIPTION
The WALTER KIDDE type Halon 1211 fire extinguisher(part number 898052) consists of three main components:
- The bottle- The operating head- The agent.
UTILIZATION
For the correct operation and data of the portablefire extinguisher, refer to the label. The label onthe extinguisher contains the instructions for use,approval number, details of weight and date of lastcheck.
TMUFIRM16-T01 LEVEL 1
EFFECTIVITY 26-24-00 Page 2Mar 31/94
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 180EFFECTIVITYALL
PORTABLE FIRE EXTINGUISHERSTMUFIRM16-P01 LEVEL 1
EFFECTIVITY 26-24-00 Page 3Mar 31/94
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 181EFFECTIVITYALL
THIS PAGE INTENTIONALLY LEFT BLANK
TMUFIRM16 LEVEL 1
EFFECTIVITY 26-24-00 Page 4Mar 31/94
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 182EFFECTIVITYALL
26 - FIRE PROTECTION
26-00-00 CFDS SPECIFIC PAGE PRESENTATION
CONTENTS:Smoke Detection Control Unit (SDCU)Last Leg ReportOn Ground FaultsWiring Report
TMUFIAQ02 LEVEL 3
EFFECTIVITY 26-00-00 Page 1Nov 30/99
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 183EFFECTIVITYALL
CFDS SPECIFIC PAGE PRESENTATION
SMOKE DETECTION CONTROL UNIT
LAST LEG REPORT- The philosophy of the LAST LEG REPORT is thesame as the one described in ATA Chapter 31,but a complementary data message concerningthe failure is given for touble shooting.
- Trouble shooting data message:This message contains data constituting asnapshot of the system at the moment of thefailure.
ON GROUND FAULTS- This item presents all class failures on groundwith the date of the last occurance of thefailure and the associated trouble shootingdata of each failure.
WIRING REPORT- This item indicates the affected area if awiring failure on the smoke detectorbus-system is recognized.
TMUFIAQ02-T01 LEVEL 3
EFFECTIVITY 26-00-00 Page 2Nov 30/99
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 184EFFECTIVITYALL
TMUFIAQ02-P01 LEVEL 3
CFDS SPECIFIC PAGE PRESENTATION
EFFECTIVITY 26-00-00 Page 3Nov 30/99
_A319/A320/A321 TECHNICAL TRAINING MANUAL26 FIRE PROTECTIONMECHANICS / ELECTRICS & AVIONICS COURSE
UFD4200
Page 185EFFECTIVITYALL
Recommended