A Comparative Study on Different
Photovoltaic Array Topologies under
Partial Shading Conditions
Moein Jazayeri, Sener Uysal, Kian Jazayeri Electrical and Electronic Eng. Dept., Eastern Mediterranean University
Famagusta, North Cyprus, Turkey
1
Introduction The study proposes comparative analyses on the performances of
different PV array topologies under various irradiance conditions.
Appropriate configuration of PV systems is considered to improve the
performance under various environmental conditions.
“Series-Parallel (SP)”, “Bridge-Link (BL)” and “Total-Cross-Tied
(TCT)” configurations are considered.
Simulation models for PV array topologies are constructed in
Matlab/SIMULNIK and the performances are analyzed with and
without application of bypass diodes.
2
Modeling & Simulation of the PV Array
3
“Simulated I-V and P-V Curves for
SOLAREX MSX-60 Solar Module”
The proposed PV array includes 36
PV modules in a 6x6 array
configuration.
One-Diode mathematical model of a
solar cell is utilized for modeling
purposes.
Modeling & Simulation of the PV Array
“Simulation model for a 6x6 Series-Parallel PV Array”
4
Modeling & Simulation of the PV Array
5
“Simulation model for a 6x6 Total-Cross-Tied PV Array”
Modeling & Simulation of the PV Array
6
“Simulation model for a 6x6 Bridge-Link PV Array”
Modeling & Simulation of Partial Shading Effects
Pattern
No. Shading Scenario No. of Fully
Shaded
Modules
No. of Partial
Shaded
Modules
No. of Fully
Illuminated
Modules
1 The cloud center locates on the
corner of the array 4 12 20
2 The cloud enters the array from the
bottom (Row-wise shading) 12 12 12
3 The cloud enters the array from the
left side (Column-wise shading) 12 12 12
4 The array enters the array from the
top (Row-wise shading) 12 12 12
5 The cloud center covers 4 modules
at the middle of the array 4 12 20
6 The 4 modules at the middle are
fully illuminated 20 12 4
7
Simulation Results
8
“Array P-V Characteristics
for Column-Wise shading”
“Array P-V Characteristics
for Row-Wise shading”
Simulation Results
9
Simulation Results
10
Conclusions
Without Bypass Diodes With Bypass Diodes
BL TCT BL TCT
Maximum
Improvement in Pmax
9% 10% 2.8% 5.84%
11
Different PV array topologies show similar performances
under identical illumination.
TCT configuration outperforms SP and BL interconnections
under partial shading conditions.
Maximum improvement with bypass diodes: 93.41% (Row-
Wise Shading).
Thanks for your patience and attention …