Cables Contents ‐ Pg 4 & 5
Search Lights Flood Lights Navigation Lights Watertight Fluorescent Ceiling Lights Non‐Watertight Fluorescent Ceiling Lights Mirror Lights Berth Lights Corner Lights Desk Lights Chart Table Lights Down Lights Decorative Wall Lights Watertight Incandescent Lights Portable Hand Lamps
Lightings Contents ‐ Pg 28
ATEX Fluorescent Lights Ex‐Proof Incandescent Lights ATEX Flood Lights Helideck Equipments ATEX Sounders/Beacons Ex‐Proof Wiring Devices Ex‐Proof Junction/Joint Box Flash Lights Pneumatic Lights Ex‐Proof Cable Glands Ex‐Proof Enclosure
Equipments for Hazardous Areas Contents ‐ Pg 42
Cable Glands Junction Boxes/Enclosures Terminal Strips/Blocks/Mounting Rails Cable Markers/Marker Strips Cable Ties/Marker Straps Band Straps/Buckles/Tools Sealing Compounds Cable Ladder/Tray Tubes/Sleeves Cable Terminals/Ferrules Tools & Accessories ‐ Cable Terminals Cable Markers Cable Clips/Clamps/Saddles Insulation Materials Soldering Tools/Accessories Insulation Tapes Cable Carrier
Cable Accessories Contents ‐ Pg 64
Ballasts Ignitor Capacitor Starter Fluorescent Lamp Holders Starter Holder/Terminal Block Lamp Holders Search Light Holder Navigation Light Lamp Holder Halogen Lamp Holder Glass Globes/Guards
Lighting Components Contents ‐ Pg 88
Rough Service Lamps Standard Lamps Emergency Battery Lamps Rough Service/Standard Lamp E‐40 Colour Lamp Navigation Lamps Compass/Signal/Smoke Detector/Buoy Lamp Miniature/Pilot Lamps Sealed Beam Lamps Reflector Lamps HID Lamps Xenon Lamp Halogen Lamps Flash light Bulbs Search Light Lamps Fluorescent Lamps Compact Energy Saving Lamps Architectural/Striplite Lamp
Lamps Contents ‐ Pg 95
AC/DC Adaptor Measuring Instruments Batteries/Batteries Accessories Flashlights Aerosols Portable Ventilation Fan/Blower Hot Air Gun/Fan Heater I.T Hardware & Software
Other Products Contents ‐ Pg 138
Fuses Relays Timers Transformer Power Supply Hour Counter Mastervolt Ventilation Fan Schneider ABB Terasaki
Switchboard Control & Automation Contents ‐ Pg 116
Extension Cable Reel/Socket Distribution Box Wonpro
Mennekes Gewiss Sanshin Wiska PDL Switches Wiring Accessories
Wiring Devices Contents ‐ Pg 52
Ship Horn Alarm Equipments
Ship Horn & Alarm Equipment Contents ‐ Pg 38
BH Global Marine Limited is a supply chain management company
specialising in premium lightings, cables and electrical equipments.
We provide one stop solution for electrical supplies for marine offshore, oil & gas
industries.
Cables
Pg 4
www.bhglobal.com.sg
CABLES CONTENTSCABLES CONTENTS TFKable Shipboard Cables
NKOXSekw 0.6/1 kV - Page 6 NKOXSekw FLEX 0.6/1 kV - Page 6 - 7 NTKOXSekw 150/250(300V) - Page 7 NTKOXSekf/ekw 150/250V - Page 7 NKOXS 0.6/1 kV - Page 7 - 8 KONS 0.6/1 kV - Page 8 NKOGSekw 0.6/1 kV - Page 8 NTKOGSekw 150/250V - Page 8 - 9 MVEPRHXCuHX 8.7/15kV - Page 9
Prysmian Shipboard Cables HFX-A/Cu 0.6/1kV - Page 9 HFX-OSA/Cu 250V - Page 9 HFX-ISOSA/Cu 250V - Page 10 HFX-A/Cu-FR 0.6/1kV - Page 10 HFX-OSA/Cu-FR 250V - Page 10 HFX-ISOSA/Cu-FR 250V - Page 10 - 11
SEC Shipboard Cables HF-CXO 0.6/1 kV - Page 11 HF-CXOSA 0.6/1kV - Page 11 - 12 HF-IXOSA 150/250V - Page 12 HF-IXO(I)SA 150/250V - Page 12 - 13 HFF-CX 06/1kV - Page 13 FRHF-CXOSA 06/1kV - Page 13 - 14 FRHF-IXOSA 150/250V - Page 14 FRHF-IXO(I)SA 150/250V - Page 14 HF-CXOSA 6/10kV - Page 14
Nexans Shipboard Cables MPRX 0.6/1kV - Page 15 MPRXCX 250V, 0.6/1kV - Page 15 MPRXCX-FLEX 0.6/1kV - Page 15 TCX(C) 150/250V - Page 15 - 16
TCX(I) 150/250V - Page 16 MPRXCX 331 250V, 0.6/1kV - Page 16 TCX(C) 331 150/250V - Page 16 - 17 TCX(I) 331 150/250V - Page 17
Unika FPSO Cables U-HF m 0.6/1 kV - Page 17 U-HFA m 0.6/1 kV - Page 17 - 18 U-HFAT m (C) 250V - Page 18 U-HFAT m (I) 250V - Page 18 U-HFAT m (I+C) 250V - Page 18 - 19 U-HFFRA m 0.6/1 kV - Page 19 U-HFFRAT m (C) 250V - Page 19 U-HFFRAT m (I+C) 250V - Page 19 - 20 U-HFA m EMC 0.6/1 kV - Page 20 U-HFA m VFD 1.8/3 kV - Page 20
NEK606 Offshore Cables P1/P8 RFOU 0.6/1kV - Page 20 - 21 S1/S5 RFOU(I) 150/250V - Page 21 P5/P12 BFOU 0.6/1kV - Page 21 - 22 S3/S7 BFOU(I) 150/250V - Page 22 - 23
Industrial Cables H07RN-F 450/750V - Page 23 - 24 H05RN-F 300/500V - Page 24 H05V-K 300/500V - Page 24 H07V-K 450/750V - Page 24 H05VV-F 300/500V - Page 25 VCTF 300/500V - Page 25 VCTFB 300/500V - Page 25 S1HF 300/500V - Page 25 SGW - Page 25 WCT Welding Cable - Page 26 H01N2-D Welding Cable - Page 26
Cables ORDERLINE +65 6291 4444
Marine and Offshore Electrical Supply Pg 5
CABLES CONTENTSCABLES CONTENTS Industrial Cables
NSHTOU 0.6/1kV - Page 26
Data and Antenna Cables RG - Coaxial Cable - Page 26 Class Approval Coaxial Cable - Page 26 Class Approval CAT 7 Lan Cable - Page 26 Class Approval Can Bus Cable - Page 26 Class Approval AS-Interface Cable - Page 26 - 27 Class Approval Profibus Cable - Page 27
Cables
Pg 6
www.bhglobal.com.sg
Number of Cross Sectional Area of Conductor (mm2)
Min Overall Diameter (mm)
Max Overall Diameter (mm)
Approx Net Weight of Cables (kg/km)
BH Code
1 x 1.5 6.3 7.7 76 A1021001
1 x 2.5 6.7 8.2 89 A1021002
1 x 4 7.4 9 115 A1021004
1 x 6 7.9 9.6 138 A1021006
1 x 10 8.7 10.5 186 A1021010
1 x 16 10 12 265 A1021016
1 x 25 11.5 14 384 A1021025
1 x 35 13 16 526 A1021035
1 x 50 14.5 17.5 677 A1021050
1 x 70 16.5 20 918 A1021070
1 x 95 18.5 22.5 1205 A1021095
1 x 120 20 24.5 1459 A1021120
1 x 150 22.5 26.5 1787 A1021150
1 x 185 25 29.5 2217 A1021185
1 x 240 27.5 32.5 2818 A1021240
1 x 300 30 35.5 3446 A1021300
2 x 1 8.8 10.5 131 A1022000
2 x 1.5 9.3 11.5 154 A1022001
2 x 2.5 10 12.5 191 A1022002
2 x 4 11 13.5 242 A1022004
2 x 6 13 15.5 346 A1022006
2 x 10 14.5 17.5 475 A1022010
2 x 16 16.5 20 671 A1022016
2 x 25 20 24 987 A1022025
2 x 35 22.5 27 1259 A1022035
2 x 50 25.5 30.5 1641 A1022050
3 x 1 9.2 11 144 A1023000
3 x 1.5 10 12 177 A1023001
3 x 2.5 10.5 13 222 A1023002
3 x 4 11.5 14.5 289 A1023004
3 x 6 13.5 16.5 403 A1023006
3 x 10 15.5 19 573 A1023010
3 x 16 17.5 21 817 A1023016
3 x 25 21.5 26 1245 A1023025
3 x 35 24 28.5 1606 A1023035
3 x 50 27 32.5 2119 A1023050
3 x 70 31.5 37.5 2911 A1023070
3 x 95 36 43 3963 A1023095
3 x 120 40 47.5 4916 A1023120
3 x 150 45 53 6120 A1023150
3 x 185 50 59 7524 A1023185
3 x 240 56 66 9640 A1023240
4 x 1 10 12 171 A1024000
4 x 1.5 10.5 13 203 A1024001
4 x 2.5 11.5 14 259 A1024002
Number of Cross Sectional Area of Conductor (mm2)
Min Overall Diameter (mm)
Max Overall Diameter (mm)
Approx Net Weight of Cables (kg/km)
BH Code
4 x 4 13.5 16 375 A1024004
4 x 6 14.5 17.5 486 A1024006
4 x 10 17.5 20.5 696 A1024010
4 x 16 19.5 23 1010 A1024016
4 x 25 23.5 28.5 1546 A1024025
4 x 35 26.5 31.5 2000 A1024035
4 x 50 30 35.5 2648 A1024050
4 x 70 35 42 3764 A1024070
4 x 95 40.5 48.5 5105 A1024095
4 x 120 45 53.5 6309 A1024120
5 x 1 10.5 13 197 A1025000
5 x 1.5 11.5 14 237 A1025001
5 x 2.5 13 15.5 341 A1025002
5 x 4 15.5 18.5 491 A1025004
5 x 6 17 20.5 636 A1025006
5 x 10 19.5 23.5 898 A1025010
5 x 16 22.5 26.5 1294 A1025016
5 x 25 26.5 232 1940 A1025025
5 x 35 30 35.5 2517 A1025035
7 x 1 11.5 14 232 A1026070
7 x 1.5 13 15.5 320 A1026071
7 x 2.5 14 17 419 A1026072
8 x 1.5 14.5 17 370 A1026081
9 x 1 ‐ ‐ ‐ A1026090
9 x 1.5 15.5 18.5 415 A1026091
10 x 1 14.5 17.5 369 A1026100
10 x 1.5 16 19 442 A1026101
10 x 2.5 17.5 21 588 A1026102
12 x 1 15 18 403 A1026120
12 x 1.5 16.5 19.5 496 A1026121
12 x 2.5 18 21.5 644 A1026122
16 x 1 16.5 20 489 A1026160
16 x 1.5 18 21.5 595 A1026161
16 x 2.5 20 23.5 793 A1026162
19 x 1 17..5 20.5 533 A1026190
19 x 1.5 19 22.5 672 A1026191
19 x 2.5 21 25 909 A1026192
20 x 1.5 20 23.5 706 A1026201
24 x 1 20 23.5 658 A1026240
24 x 1.5 22 26 830 A1026241
24 x 2.5 24.5 29 1134 A1026242
27 x 1 20.5 24.5 709 A1026270
27 x 1.5 22.5 26.5 886 A1026271
30 x 1.5 23.5 27.5 977 A1026301
37 x 1 23 27 881 A1026370
37 x 1.5 25 29.5 1131 A1026371
TFKable Shipboard Cables
NKOXSekw 0.6/1kV
NKOXSekw FLEX 0.6/1kV
Number of Cross Sectional Area of Conductor (mm2)
Min Overall Diameter (mm)
Max Overall Diameter (mm)
Approx Net Weight of Cables (kg/km)
BH Code
1 x 185 26 31 2113 A1021186
Test Performances Flame Retardant : IEC 60332-3-22 Category A Smoke Emission : IEC 61034-2 Gases evolved during combustion : IEC 60754-1 : < 0.5% acid gas IEC 60754-2 : pH>=4.3; conductivity <= 10 uSmm-1 Standards Construction and Design : IEC 60228, IEC 60092-350, IEC 60092-353 Materials : IEC 60092-351, IEC 60092-359
Type Approval Certificates - American Bureau of Shipping - Det Norske Veritas - Germanischer Lloyd - Bureau Veritas - Lloyd’s Register - NIPPON KAIJI KYOKAI - Russian Maritime Register of Shipping
Application Fixed Installations in all areas and open deck Copper wire braiding provides shielding against EMI
Halogen Free Low Smoke Power Cables, with Copper Wire Braiding
Test Performance Flame Retardant : IEC 60332-3-22 Category A Smoke Emission : IEC 61034-2 Gases evolved during combustion : IEC 60754-1 : < 0.5% acid gas IEC 60754-2 : pH>=4.3; conductivity <= 10 uSmm-1 Standards Construction and Design : IEC 60228, IEC 60092-350, IEC 60092-353 Materials : IEC 60092-351, IEC 60092-359
Type Approval Certificates - American Bureau of Shipping - Det Norske Veritas - Germanischer Lloyd - Bureau Veritas - NIPPON KAIJI KYOKAI - Russian Maritime Register of Shipping
Application Fixed Installations in all areas and open deck Copper wire braiding provides shielding against EMI
Halogen Free Low Smoke Power Cables, with Copper Wire Braiding, Class 5 Conductors
Cables ORDERLINE +65 6291 4444
Marine and Offshore Electrical Supply Pg 7
Number of Cross Sectional Area of Conductor (mm2)
Min Overall Diameter (mm)
Max Overall Diameter (mm)
Approx Net Weight of Cables (kg/km)
BH Code
1 x 240 29 24.5 2669 A1021241
1 x 300 31.5 37.5 3290 A1021301
3 x 50 29.5 35 2120 A1023051
3 x 70 33 40 2880 A1023071
3 x 95 38 45.5 3816 A1023096
3 x 120 42 50 4732 A1023121
3 x 150 47.5 56.5 5969 A1023151
3 x 185 52 62 7269 A1023186
3 x 240 59 69.5 9125 A1023241
4 x 50 32.5 38.5 2663 A1024051
4 x70 37 45 3739 A1024071
4 x 95 43 51.5 4930 A1024096
4 x 120 47.5 56.5 6092 A1024121
4 x 150 52.5 62.5 7522 A1024151
Number of Cross Sectional Area of Conductor (mm2)
Min Overall Diameter (mm)
Max Overall Diameter (mm)
Approx Net Weight of Cables (kg/km)
BH Code
60V 0.5mm2 1 x 2 x 0.5 6.3 7.8 74 A1030120
1 x 4 x 0.5 6.9 8.6 97 A1030140
2 x 2 x 0.5 8.6 10.5 114 A1030220
4 x 2 x 0.5 9.6 11.5 154 A1030420
7 x 2 x 0.5 11 13.5 222 A1030720
10 x 2 x 0.5 14.5 17.5 341 A1031020
14 x 2 x 0.5 15.5 18.5 419 A1031420
19 x 2 x 0.5 17.5 20.5 505 A1031920
24 x 2 x 0.5 20 24 638 A1032400
37 x 2 x 0.5 23 27 868 A1033700
250V 0.75mm2 1 x 2 x 0.75 7.1 8.8 91 A1030121
1 x 3 x 0.75 7.5 9.2 102 A1030131
1 x 4 x 0.75 8 9.8 121 A1030141
2 x 2 x 0.75 10 12 140 A1030221
4 x 2 x 0.75 12.5 14 208 A1030421
7 x 2 x 0.75 13.5 16.5 286 A1030721
10 x 2 x 0.75 17.5 21 448 A1031021
14 x 2 x 0.75 19 22.5 552 A1031421
19 x 2 x 0.75 21 25 692 A1031921
24 x 2 x 0.75 24.5 29 855 A1032421
37 x 2 x 0.75 28.5 33.5 1188 A1033701
1 x 2 x 1.5 8.2 10.1 123 A1030122
1 x 3 x 1.5 8.8 11 148 A1030132
1 x 4 x 1.5 9.5 11.5 176 A1030142
2 x 2 x 1.5 12 14.5 208 A1030222
4 x 2 x 1.5 14 17 355 A1030422
7 x 2 x 1.5 17 20.5 508 A1030722
10 x 2 x 1.5 21.5 25.5 699 A1031022
14 x 2 x 1.5 23 26.5 788 A1031422
19 x 2 x 1.5 26 30.5 1139 A1031922
24 x 2 x 1.5 30.5 36 1421 A1032402
37 x 2 x 1.5 35 41.5 1998 A1033702
250V 1.5mm2
NTKOXSekw 150/250 (300V)
Test Performance Flame Retardant : IEC 60332-3-22 Category A Smoke Emission : IEC 61034-2 Gases evolved during combustion : IEC 60754-1 : < 0.5% acid gas IEC 60754-2 : pH>=4.3; conductivity <= 10 uSmm-1 Standards Construction and Design : IEC 60228, IEC 60092-350, IEC 60092-376 Materials : IEC 60092-351, IEC 60092-359
Type Approval Certificates - American Bureau of Shipping - Det Norske Veritas - Germanischer Lloyd - Bureau Veritas - Lloyd’s Register - NIPPON KAIJI KYOKAI - Russian Maritime Register of Shipping
Application Interconnection of all sorts of instrumentation and communication equipment Copper wire braiding provides shielding against EMI
Number of Cross Sectional Area of Conductor (mm2)
Min Overall Diameter (mm)
Max Overall Diameter (mm)
Approx Net Weight of Cables (kg/km)
BH code
1 x 2 x 0.75 9.3 11 149 A1040121
1 x 3 x 0.75 9.6 11.5 163 A1040131
2 x 2 x 0.75 12.5 15 254 A1040221
4 x 2 x 0.75 14 17 339 A1040421
7 x 2 x 0.75 17 20.5 510 A1040721
10 x 2 x 0.75 21 24.5 694 A1041021
14 x 2 x 0.75 22.5 26.5 857 A1041421
19 x 2 x 0.75 25 29.5 1061 A1041921
24 x 2 x 0.75 28.5 33.5 1299 A1042421
37 x 2 x 0.75 32.5 38 1744 A1043721
2 x 2 x 1.5 14.5 17.5 344 A1040222
4 x 2 x 1.5 17 20.5 539 A1040422
7 x 2 x 1.5 20 24 744 A1040722
10 x 2 x 1.5 25 29.5 1041 A1041022
Test Performance Flame Retardant : IEC 60332-3-22 Category A Smoke Emission : IEC 61034-2 Gases evolved during combustion : IEC 60754-1 : < 0.5% acid gas IEC 60754-2 : pH>= 4.3; conductivity <= 10 uSmm-1 Standards Construction and Design : IEC 60228, IEC 60092-350, IEC 60092-376 Materials : IEC 60092-351, IEC 60092-359
Type Approval Certificates - American Bureau of Shipping - Det Norske Veritas - Germanischer Lloyd - Lloyd’s Register - Bureau Veritas - NIPPON KAIJI KYOKAI - Russian Maritime Register of Shipping
Application Interconnection of all sorts of instrumentation and communication equipment Copper wire braiding provides shielding against EMI
Halogen Free Low Smoke Instrumentation Control and Telecommunication Cables, Individual Pair Screen with Copper Wire Braiding.
NTKOXSekf/ekw 150/250 (300V)
Number of Cross Sectional Area of Conductor (mm2)
Min Overall Diameter (mm)
Max Overall Diameter (mm)
Approx Net Weight of Cables (kg/km)
BH Code
1 x 1.5 4.7 5.8 38 A1010011
1 x 2.5 5 6.3 49 A1010021
1 x 4 5.4 6.9 66 A1010041
1 x 6 6 7.5 87 A1010061
1 x 10 7 8.7 132 A1010101
1 x 16 7.9 9.8 198 A1010168
1 x 25 9.7 12 306 A1010258
1 x 35 10.5 13 400 A1010358
1 x 50 12 15 536 A1010508
1 x 70 14 17 747 A1010708
1 x 95 16 19.5 1010 A1010958
1 x 120 17.5 21.5 1259 A1011208
1 x 150 19.5 23.5 1542 A1011508
1 x 300 27 32 3077 A1013008
2 x 1.5 8.3 10.5 116 A1012001
2 x 2.5 9.1 11 149 A1012002
2 x 4 10 12.5 201 A1012004
NKOXS 0.6/1 kV
Test Performance Flame Retardant : IEC 60332-3-22 Category A Smoke Emission : IEC 61034-2 Gases evolved during combustion : IEC 60754-1 : < 0.5% acid gas IEC 60754-2 : pH>= 4.3; conductivity <= 10 uSmm-1 Standards Construction and Design : IEC 60228, IEC 60092-350, IEC 60092-353 Materials : IEC 60092-351, IEC 60092-359
Type Approval Certificates - American Bureau of Shipping - Det Norske Veritas - Germanischer Lloyd - Lloyd’s Register - Bureau Veritas - NIPPON KAIJI KYOKAI - Russian Maritime Register of Shipping
Application Fixed installations in all areas in ships
Halogen Free Low Smoke Power Cables
Halogen Free Low Smoke Instrumentation Control and Telecommunication Cables, Overall Screen with Copper Wire Braiding.
Cables
Pg 8
www.bhglobal.com.sg
Number of Cross Sectional Area of Conductor (mm2)
Min Overall Diameter (mm)
Max Overall Diameter (mm)
Approx Net Weight of Cables (kg/km)
BH Code
3 x 1.5 8.8 11 133 A1013001
3 x 2.5 9.8 12 179 A1013002
3 x 4 10.5 13 239 A1013004
3 x 6 12 14.5 315 A1013006
4 x 1.5 9.7 12 160 A1014001
4 x 2.5 10.5 13 213 A1014002
Number of Cross Sectional Area of Conductor (mm2)
Min Overall Diameter (mm)
Max Overall Diameter (mm)
Approx Net Weight of Cables (kg/km)
BH Code
1 x 0.75 2.4 3.1 13 A1080001
1 x 1 2.4 3.2 15 A1080011
1 x 1.5 2.7 3.5 19 A1080021
1 x 2.5 3.1 4 30 A1080031
1 x 4 3.6 4.6 44 A1080041
1 x 6 4.2 5.2 62 A1080061
1 x 10 5.2 6.6 105 A1080101
1 x 16 6.2 7.8 159 A1080161
1 x 25 7.6 9.6 245 A1080251
1 x 35 9 11.5 332 A1080351
1 x 50 10.5 13.5 479 A1080501
1 x 70 12 15.5 664 A1080701
1 x 95 14 17.5 879 A1080951
1 x 120 15.5 19.5 1104 A1081201
Number of Cross Sectional Area of Conductor (mm2)
Min Overall Diameter (mm)
Max Overall Diameter (mm)
Approx Net Weight of Cables (kg/km)
BH Code
1 x 25 13 15.5 431 A1121025
1 x 35 14.5 17.5 587 A1121035
1 x 50 16.5 19.5 756 A1121050
1 x 70 18 21.5 979 A1121070
1 x 95 20 24 1288 A1121095
1 x 120 22 26 1558 A1121120
Number of Cross Sectional Area of Conductor (mm2)
Min Overall Diameter (mm)
Max Overall Diameter (mm)
Approx Net Weight of Cable (kg/km)
BH Code
1 x 150 23.5 28 1859 A1121150
1 x 300 31.5 37 3496 A1121300
2 x 1.5 11 13.5 220 A1122000
2 x 2.5 12 14.5 267 A1122002
2 x 4 13.5 16 373 A1122004
2 x 6 14.5 17.5 423 A1122006
2 x 10 16.5 19.5 569 A1122010
2 x 16 18.5 22 759 A1122016
2 x 25 22.5 26.5 11110 A1122025
2 x 35 24.5 29 1382 A1122035
2 x 50 27.5 33 1827 A1122050
3 x 1.5 11.5 14 245 A1123000
3 x 2.5 13 16 353 A1123002
3 x 4 14 17 418 A1123004
3 x 6 15.5 18.5 512 A1123006
3 x 10 17.5 20.5 686 A1123010
3 x 16 19.5 23.5 926 A1123016
3 x 25 23.5 28 1353 A1123025
3 x 35 26 31 1728 A1123035
3 x 50 29.5 35 2270 A1123050
3 x 70 33.5 40 3020 A1123070
3 x 95 39 46.5 4193 A1123095
3 x 120 42 50 5069 A1123120
3 x 150 47 55 6195 A1123150
3 x 185 51.5 61 7562 A1123186
4 x 1.5 13 16 339 A1124001
4 x 2.5 14 17 396 A1124002
4 x 4 15.5 18.5 504 A1124004
4 x 6 17 20 591 A1124006
4 x 10 19 22.5 815 A1124010
5 x 1.5 14 17 380 A1125001
5 x 2.5 15.5 18.5 478 A1125002
7 x 1.5 15 18 450 A1126071
7 x 2.5 16.5 19.5 550 A1126072
9 x 1.5 18.5 21.5 570 A1126091
10 x 1.5 19 22 610 A1126101
12 x 1.5 19.5 23 677 A1126121
12 x 2.5 21 25 860 A1126122
16 x 1.5 21.5 25 828 A1126161
16 x 2.5 23.5 27.5 1049 A1126162
19 x 1.5 22.5 26.5 904 A1126191
24 x 1.5 26.5 30.5 1140 A1126241
24 x 2.5 28.5 33.5 1478 A1126242
30 x 1.5 27.5 32 1323 A1126301
37 x 1.5 30 34.5 1529 A1126371
Test Performance Flame Retardant : IEC 60332-1-2 Smoke Emission : IEC 61034-2 Gases evolved during combustion : IEC 60754-1 : < 0.5% acid gas IEC 60754-2 : pH>= 4.3; conductivity <= 10 uSmm-1 Standards Construction and Design : IEC 60228, IEC 60092-350, IEC 60092-354 Materials : IEC 60092-351, IEC 60092-359
Application Fixed wiring in switchboards, control panels and other enclosures
Halogen Free Low Smoke Switchboard Wire
KONS 0.6/1 kV
NKOGsekw 0.6/1 kV
Test Performance Fire Resistant : IEC 60331-21 : 3h, 950oC Flame Retardant : IEC 60332-3-22 Category A Smoke Emission : IEC 61034-2 : transmittance values > 70% Gases evolved during combustion : IEC 60754-1 : < 0.5% acid gas IEC 60754-2 : pH>= 4.3; conductivity <= 10 uSmm-1 Standards Construction and Design : IEC 60228, IEC 60092-350, IEC 60092-353 Materials : IEC 60092-351, IEC 60092-359
Application Fire resistant cables for fixed installations in all areas and open deck Copper wire braiding provides shielding against EMI
Halogen Free Low Smoke Fire Resistant Power Cables with Copper Wire Braiding
Number of Cross Sectional Area of Conductor (mm2)
Min Overall Diameter (mm)
Max Overall Diameter (mm)
Approx Net Weight of Cables (kg/km)
BH Code
1 x 2 x 0.75 7.1 8.8 91 A1130121
1 x 4 x 0.75 8 9.8 121 A1130141
2 x 2 x 0.75 10.5 13 175 A1130221
250V 0.75mm2
NTKOGsekw 150/250V (300V)
Test Performance Fire Resistant : IEC 60331-21 : 3h, 950oC Flame Retardant : IEC 60332-3-22 Category A Smoke Emission : IEC 61034-2 : transmittance values > 70% Gases evolved during combustion : IEC 60754-1 : < 0.5% acid gas IEC 60754-2 : pH>= 4.3; conductivity <= 10 uSmm-1 Standards Construction and Design : IEC 60228, IEC 60092-350, IEC 60092-376 Materials : IEC 60092-351, IEC 60092-359
Application Fire resistant cables, interconnection of all sorts of instrumentation and communication equipment Copper wire braiding provides shielding against EMI
Halogen Free Low Smoke Fire Resistant Instrumentation Control and Telecommunication Cables, Overall Screen with Copper Wire Braiding.
Type Approval Certificates - Det Norske Veritas
Type Approval Certificates - American Bureau of Shipping - Det Norske Veritas - Germanischer Lloyd - Lloyd’s Register - Bureau Veritas - NIPPON KAIJI KYOKAI - Russian Maritime Register of Shipping
Type Approval Certificates - American Bureau of Shipping - Det Norske Veritas - Germanischer Lloyd - Lloyd’s Register - Bureau Veritas - NIPPON KAIJI KYOKAI - Russian Maritime Register of Shipping
Cables ORDERLINE +65 6291 4444
Marine and Offshore Electrical Supply Pg 9
Prysmian Shipboard Cables
Number of Cross Sectional Area of Conductor (mm2)
Min Overall Diameter (mm)
Max Overall Diameter (mm)
Approx Net Weight of Cables
(kg/km) BH Code
3 x 35 49.5 54.5 4438 A1433035
3 x 70 56 61.5 6175 A1433070
3 x 95 59.5 65.5 7325 A1433095
3 x 150 66.5 73.5 9744 A1433150
Number of Cross Sectional Area of Conductor (mm2)
Min Overall Diameter (mm)
Max Overall Diameter (mm)
Approx Net Weight of Cables (kg/km)
BH Code
4 x 2 x 0.75 11.5 14 208 A1130421
7 x 2 x 0.75 13.5 16.5 286 A1130721
10 x 2 x 0.75 17.5 21 448 A1131021
14 x 2 x 0.75 19 22.5 552 A1131421
19 x 2 x 0.75 21 25 692 A1131921
24 x 2 x 0.75 24.5 29 855 A1132421
37 x 2 x 0.75 28.5 33.5 1188 A1133721
1 x 2 x 1.5 8.2 10.1 123 A1130122
2 x 2 x 1.5 12.5 15 258 A1130222
4 x 2 x 1.5 14 17 355 A1130422
7 x 2 x 1.5 17 20.5 508 A1130722
10 x 2 x1.5 21.5 25.5 699 A1131022
14 x 2 x 1.5 23 27.5 896 A1131422
19 x 2 x 1.5 26 30.5 1139 A1131922
250V 1.5mm2
MVEPRHXCuHX 8.7/15 (17.5) kV
Test Performance Flame Retardant : IEC 60332-3-22 Category A Smoke Emission : IEC 61034-2 Gases evolved during combustion : IEC 60754-1 : < 0.5% acid gas IEC 60754-2 : pH>= 4.3; conductivity <= 10 uSmm-1 Standards Construction and Design : IEC 60228, IEC 60092-350, IEC 60092-354 Materials : IEC 60092-351, IEC 60092-359
Application Fixed installations in all areas and open deck
Halogen Free Low Smoke Medium Voltage Power Cables with Copper Wire Braiding
HFX‐A/Cu 0.6/1kV
Number of Cross Sectional Area of Conductor (mm2)
Min Overall Diameter (mm)
Max Overall Diameter (mm)
Approx Net Weight of Cables (kg/km)
BH Code
3 x 25 22.5 24 1120 A2023025
3 x 35 26.5 28 1660 A2023035
3 x 50 29 30.5 2100 A2023050
3 x 70 34 36 2950 A2023070
3 x 95 38.5 40.5 4010 A2023095
3 x 120 42 44 4990 A2023120
3 x 150 47.5 50 6150 A2023150
4 x 1.5 10.8 11.8 180 A2024001
4 x 2.5 12.2 23.2 225 A2024002
4 x 4 13.4 14.4 305 A2024004
4 x 6 15.5 16.5 410 A2024006
4 x 10 18 19 635 A2024010
4 x 16 20.5 22 905 A2024016
4 x 25 25 26.5 1360 A2024025
5 x 1.5 12 13 200 A2025001
7 x 1.5 12.8 13.8 245 A2026071
10 x 1.5 ‐ ‐ ‐ A2026101
12 x 1.5 17.5 18.5 435 A2026121
16 x 1.5 19 20 530 A2026161
19 x 1.5 20 21.5 610 A2026191
24 x 1.5 23.5 25 760 A2026241
27 x 1.5 24 25.5 730 A2026271
37 x 1.5 26.5 28 1060 A2026371
HFX‐OSA/Cu 250V
Number of Cross Sectional Area of Conductor (mm2)
Min Overall Diameter (mm)
Max Overall Diameter (mm)
Approx Net Weight of Cables (kg/km)
BH Code
2 x 1.5 9.6 10.6 120 A2022001
2 x 2.5 10.6 11.6 150 A2022002
2 x 4 11.8 12.8 195 A2022004
2 x 6 13 14 275 A2022006
2 x 10 15.5 16.5 425 A2022010
2 x 16 18 19 590 A2022016
3 x 1.5 10.2 11.2 145 A2023001
3 x 2.5 11 12 185 A2023002
3 x 4 12.4 13.4 243 A2023004
3 x 6 13.6 14.6 340 A2023006
3 x 10 16.5 17.5 520 A2023010
3 x 16 19 20 750 A2023016
Test Performance Flame Retardant : IEC 60332-1 Flame Retardant on bunched cables : IEC 60332-3A Smoke Emission : IEC 61034-1, IEC 61034-2 Halogen free properties : IEC 60754-1, IEC60754-2 Standards Construction and Design : IEC 60092-350, IEC 60092-353 Materials : IEC 60092-351, IEC 60092-359
Halogen Free Low Smoke Power Cables with Copper Wire Braiding
Test Performance Flame Retardant : IEC 60332-1 Flame Retardant on bunched cables : IEC 60332-3A Smoke Emission : IEC 61034-1, IEC 61034-2 Halogen free properties : IEC 60754-1, IEC60754-2 Standards Construction and Design : IEC 60092-3, IEC 60092-375 Materials : IEC 60092-351, IEC 60092-359
Halogen Free Low Smoke Collectively Screened and Armoured Telecommunication and Instrumentation Cables, Overall Screen with Copper Wire Braiding.
Type Approval Certificates - American Bureau of Shipping - Det Norske Veritas - Russian Maritime Register of Shipping
Number of Cross Sectional Area of Conductor (mm2)
Max Overall Diameter (mm)
Approx Net Weight of Cables (kg/km)
BH Code
1 x 2 x 0.75 10.5 105 A2030121
1 x 3 x 0.75 ‐ ‐ A2030131
2 x 2 x 0.75 12.7 155 A2030221
4 x 2 x 0.75 15.8 265 A2030421
7 x 2 x 0.75 18.5 370 A2030721
10 x 2 x 0.75 22.5 500 A2031021
14 x 2 x 0.75 24.4 620 A2031421
19 x 2 x 0.75 27.3 800 A2031921
24 x 2 x 0.75 31.2 980 A2032421
37 x 2 x 0.75 ‐ ‐ A2033722
250V 1.5mm2 1 x 2 x 1.5 11.5 135 A2030122
1 x 3 x 1.5 11 160 A2030132
2 x 2 x 1.5 14.8 240 A2030222
4 x 2 x 1.5 18 365 A2030422
7 x 2 x 1.5 21.3 530 A2030722
10 x 2 x 1.5 26.2 740 A2031022
14 x 2 x 1.5 28.4 940 A2031422
19 x 2 x 1.5 31.6 1200 A2031922
24 x 2 x 1.5 36.4 1500 A2032422
37 x 2 x 1.5 ‐ ‐ A2033722
250V 0.75mm2
Cables
Pg 10
www.bhglobal.com.sg
Number of Cross Sectional Area of Conductor (mm2)
Max Overall Diameter (mm)
Approx Net Weight of Cables (kg/km)
BH Code
250V 0.75mm2 1 x 2 x 0.75 ‐ ‐ A2040121
1 x 3 x 0.75 ‐ ‐ A2041031
2 x 2 x 0.75 13.6 170 A2040221
4 x 2 x 0.75 17 300 A2040421
7 x 2 x 0.75 20.1 420 A2040721
10 x 2 x 0.75 24.9 630 A2041021
14 x 2 x 0.75 27.1 760 A2041421
19 x 2 x 0.75 30.1 1000 A2041921
24 x 2 x 0.75 34.1 1190 A2042421
37 x 2 x 0.75 34.1 1460 A2043721
1 x 2 x 1.5 ‐ ‐ A2040122
1 x 3 x 1.5 ‐ ‐ A2040132
2 x 2 x 1.5 15.7 285 A2040222
4 x 2 x 1.5 19.3 420 A2040422
7 x 2 x 1.5 22.8 620 A2040722
10 x 2 x 1.5 28.4 860 A2041022
14 x 2 x 1.5 30.9 1100 A2041422
19 x 2 x 1.5 34.7 1420 A2041922
24 x 2 x 1.5 39.9 1840 A2042422
37 x 2 x 1.5 42.3 2180 A2043722
250V 1.5mm2
HFX‐ISOSA/Cu 250V
HFX‐OSA/Cu‐FR 250V
Number of Cross Sectional Area of Conductor (mm2)
Min Overall Diameter (mm)
Max Overall Diameter (mm)
Approx Net Weight of Cables (kg/km)
BH Code
2 x 1.5 11.8 12.8 210 A2122001
2 x 2.5 13 14 250 A2122002
2 x 4 14 15 310 A2122004
3 x 1.5 12.6 13.6 240 A2123001
3 x 2.5 13.6 14.6 290 A2123002
3 x 4 14.6 15.6 355 A2123004
3 x 6 16.5 17.5 490 A2123006
3 x 10 19 20 690 A2123010
3 x 16 21.5 23 930 A2123016
3 x 25 25.5 27 1360 A2123025
3 x 35 28 29.5 1740 A2123035
3 x 50 30.5 32.5 2220 A2123050
3 x 70 35.5 37.5 3060 A2123070
3 x 95 40 42 4140 A2123095
3 x 120 44 46 5100 A2123120
HFX‐A/Cu‐FR 0.6/1kV
Number of Cross Sectional Area of Conductor (mm2)
Max Overall Diameter (mm)
Approx Net Weight of Cables (kg/km)
BH Code
1 x 2 x 0.75 ‐ ‐ A2150121
1 x 3 x 0.75 ‐ ‐ A2150131
2 x 2 x 0.75 21.6 538 A2150221
4 x 2 x 0.75 24.9 683 A2150421
250V 0.75mm2
HFX‐ISOSA/Cu‐FR 250V
Test Performance Flame Retardant : IEC 60332-1 Flame Retardant on bunched cables : IEC 60332-3A Smoke Emission : IEC 61034-1, IEC 61034-2 Halogen free properties : IEC 60754-1, IEC60754-2 Standards Construction and Design : IEC 60092-3, IEC 60092-375 Materials : IEC 60092-351, IEC 60092-359
Halogen Free Low Smoke Telecommunication and Instrumentation Cables, Individual Pair Screen with Copper Wire Braiding.
Test Performance Fire Resistant : IEC 60331 Flame Retardant : IEC 60332-1 Flame Retardant on bunched cables : IEC 60332-3A Smoke Emission : IEC 61034-1, IEC 61034-2 Halogen free properties : IEC 60754-1, IEC60754-2 Standards Construction and Design : IEC 60092-350, IEC 60092-353 Materials : IEC 60092-351, IEC 60092-359
Halogen Free Low Smoke Fire Resistant Armoured Power and Control Cables with Copper Wire Braiding
Test Performance Fire Resistant : IEC 60331 Flame Retardant : IEC 60332-1 Flame Retardant on bunched cables : IEC 60332-3A Smoke Emission : IEC 61034-1, IEC 61034-2 Halogen free properties : IEC 60754-1, IEC60754-2 Standards Construction and Design : IEC 60092-3, IEC 60092-375 Materials : IEC 60092-351, IEC 60092-359
Halogen Free Low Smoke Fire Resistant Telecommunication and Instrumentation Cables, Individual Pair Screen with Copper Wire Braiding.
Test Performance Fire Resistant : IEC 60331 Flame Retardant : IEC 60332-1 Flame Retardant on bunched cables : IEC 60332-3A Smoke Emission : IEC 61034-1, IEC 61034-2 Halogen free properties : IEC 60754-1, IEC60754-2 Standards Construction and Design : IEC 60092-3, IEC 60092-375 Materials : IEC 60092-351, IEC 60092-359
Halogen Free Low Smoke Fire Resistant Telecommunication and Instrumentation Cables, Overall Screen with Copper Wire Braiding.
Number of Cross Sectional Area of Conductor (mm2)
Max Overall Diameter (mm)
Approx Net Weight of Cables (kg/km)
BH Code
1 x 2 x 0.75 13 247 A2130121
1 x 3 x 0.75 13.8 270 A2130131
2 x 2 x 0.75 19.3 462 A2130221
4 x 2 x 0.75 22.1 576 A2130421
7 x 2 x 0.75 25.4 785 A2130721
10 x 2 x 0.75 31.5 1051 A2131021
14 x 2 x 0.75 34 1261 A2131421
19 x 2 x 0.75 37.9 1571 A2131921
24 x 2 x 0.75 44.6 1998 A2132421
37 x 2 x 0.75 ‐ ‐ A2133721
250V 1.5mm2 1 x 2 x 1.5 14.3 300 A2130122
1 x 3 x 1.5 ‐ ‐ A2130132
2 x 2 x 1.5 18.1 450 A2130222
4 x 2 x 1.5 21.6 670 A2130422
7 x 2 x 1.5 25.5 920 A2130722
10 x 2 x 1.5 30.8 1250 A2131022
14 x 2 x 1.5 33.4 1530 A2131422
19 x 2 x 1.5 37.6 1920 A2131922
24 x 2 x 1.5 43.2 2470 A2132422
37 x 2 x 1.5 ‐ ‐ A2133722
250V 0.75mm2
Number of Cross Sectional Area of Conductor (mm2)
Min Overall Diameter (mm)
Max Overall Diameter (mm)
Approx Net Weight of Cables (kg/km)
BH Code
4 x 2.5 14.6 15.6 260 A2124002
5 x 1.5 14.6 15.6 300 A2125001
7 x 1.5 16.5 17.5 370 A2126071
10 x 1.5 20 21.5 540 A2126101
12 x 1.5 20.5 22 590 A2126121
16 x 1.5 22.5 24 730 A2126161
19 x 1.5 23.5 25 820 A2126191
24 x 1.5 27.5 29 1000 A2126241
27 x 1.5 28 29.5 1080 A2126271
37 x 1.5 31 33 1380 A2126371
3 x 150 47.5 50 6150 A2123150
4 x 1.5 13.4 14.4 210 A2124001
Recommended