62368 Mark Edge 3 - psma.com2019/06/20  · MET Laboratories, Inc. First in Certification |...

Preview:

Citation preview

Laboratories, Inc. Laboratories, Inc. Laboratories, Inc. Laboratories, Inc. First in Certification

62368-1 - HBSE

Presenter: Mark Edge

Presenter Title: Technical Manager - Safety Business Line

MET Laboratories, Inc. MET Laboratories, Inc. MET Laboratories, Inc. MET Laboratories, Inc. First in Certification First in Certification First in Certification First in Certification | info@metlabs.com | www.metlabs.com

What we’ll discuss

MET Laboratories, Inc. MET Laboratories, Inc. MET Laboratories, Inc. MET Laboratories, Inc. First in Certification First in Certification First in Certification First in Certification | info@metlabs.com | www.metlabs.com

What is 62368-1?

• Standard for Safety

– Audio/video,

– information and communication technology

equipment

• HBSE – Hazard Based Safety Engineering

– Hazard based,

– Performance oriented

MET Laboratories, Inc. MET Laboratories, Inc. MET Laboratories, Inc. MET Laboratories, Inc. First in Certification First in Certification First in Certification First in Certification | info@metlabs.com | www.metlabs.com

What is 62368-1, background

• 62368 was developed by IEC TC108;

• While it is new to most of us TC108 has been working on this since 2002;

• The 1st edition was released in January of 2010 as an IEC standard

– Was not well received (only the US and 4 other countries)

– TC108 suggested that the 1st ed. be adopted not earlier than five years

MET Laboratories, Inc. MET Laboratories, Inc. MET Laboratories, Inc. MET Laboratories, Inc. First in Certification First in Certification First in Certification First in Certification | info@metlabs.com | www.metlabs.com

What is 62368-1, background

• The 2nd edition was published in February of

2014.

• Almost immediately adopted by numerous

countries

MET Laboratories, Inc. MET Laboratories, Inc. MET Laboratories, Inc. MET Laboratories, Inc. First in Certification First in Certification First in Certification First in Certification | info@metlabs.com | www.metlabs.com

What 62368-1 is NOT

• 62368 is HAZARD based not RISK based:

– Does not require or (typically) utilize an ISO/IEC

Guide 51 based or ISO 14971 (60601) type risk

management assessment

• Not a direct merging of 60065 and 60950

– Incorporates Hazard based concepts

– Has both requirements and compliance criteria

• Performance based and/or prescribed constructions

MET Laboratories, Inc. MET Laboratories, Inc. MET Laboratories, Inc. MET Laboratories, Inc. First in Certification First in Certification First in Certification First in Certification | info@metlabs.com | www.metlabs.com

Why 62368-1

MET Laboratories, Inc. MET Laboratories, Inc. MET Laboratories, Inc. MET Laboratories, Inc. First in Certification First in Certification First in Certification First in Certification | info@metlabs.com | www.metlabs.com

Why 62368-1

MET Laboratories, Inc. MET Laboratories, Inc. MET Laboratories, Inc. MET Laboratories, Inc. First in Certification First in Certification First in Certification First in Certification | info@metlabs.com | www.metlabs.com

Some “how’s” of 62368

• Introduction

– To help DESIGNERS understand the underlying

principles… to design safe equipment

– Meant to be informative

– Not an alternative to the requirements of the standard

MET Laboratories, Inc. MET Laboratories, Inc. MET Laboratories, Inc. MET Laboratories, Inc. First in Certification First in Certification First in Certification First in Certification | info@metlabs.com | www.metlabs.com

Some “how’s” of 62368

• Defines three types of persons with corresponding safeguard requirements.

Ordinary people – end users and/or those with coincidental access

MET Laboratories, Inc. MET Laboratories, Inc. MET Laboratories, Inc. MET Laboratories, Inc. First in Certification First in Certification First in Certification First in Certification | info@metlabs.com | www.metlabs.com

Some “how’s” of 62368

• Skilled persons

– Has sufficient training and experience to know the

technology and to recognize and avoid hazards

• Instructed persons

– Instructed or trained by a skilled person; or

– Supervised by a skilled person

MET Laboratories, Inc. MET Laboratories, Inc. MET Laboratories, Inc. MET Laboratories, Inc. First in Certification First in Certification First in Certification First in Certification | info@metlabs.com | www.metlabs.com

How – 62368 Model for Pain or Injury

• Classifies energy sources;

• Prescribes safeguards;

• Provides guidance on their application

MET Laboratories, Inc. MET Laboratories, Inc. MET Laboratories, Inc. MET Laboratories, Inc. First in Certification First in Certification First in Certification First in Certification | info@metlabs.com | www.metlabs.com

62368 – Forms of energy

MET Laboratories, Inc. MET Laboratories, Inc. MET Laboratories, Inc. MET Laboratories, Inc. First in Certification First in Certification First in Certification First in Certification | info@metlabs.com | www.metlabs.com

How – 62368 Energy Sources

• Energy thresholds are not constant

– Different thresholds exist for different people

(even of the same size/mass)

– Body variables include:

• Age, health, emotional state, skin characteristics…

MET Laboratories, Inc. MET Laboratories, Inc. MET Laboratories, Inc. MET Laboratories, Inc. First in Certification First in Certification First in Certification First in Certification | info@metlabs.com | www.metlabs.com

How – 62368 Energy Limits

MET Laboratories, Inc. MET Laboratories, Inc. MET Laboratories, Inc. MET Laboratories, Inc. First in Certification First in Certification First in Certification First in Certification | info@metlabs.com | www.metlabs.com

How – 62368 Energy LimitsEnergy Source 1 (ES 1); a class 1 electrical energy

source

• not exceeding the ES 1 limits under

• Normal operating conditions;

• Abnormal operating conditions; and,

• Single fault conditions of:

• A component;

• Device; or,

• Insulation

and,

• Not exceeding ES 2 limits under single fault

conditions of a Basic safeguard

}Not serving as a safeguard;

MET Laboratories, Inc. MET Laboratories, Inc. MET Laboratories, Inc. MET Laboratories, Inc. First in Certification First in Certification First in Certification First in Certification | info@metlabs.com | www.metlabs.com

How – 62368 Energy Limits

ES1 does not exceed the limits of ES 1 under

normal, abnormal, or single fault (not safeguard)

conditions.

If the source Voltage is less than the ES 1 Voltage

limits (under normal, abnormal, or single fault

conditions) the Current limit is undefined.

MET Laboratories, Inc. MET Laboratories, Inc. MET Laboratories, Inc. MET Laboratories, Inc. First in Certification First in Certification First in Certification First in Certification | info@metlabs.com | www.metlabs.com

How – 62368 Energy Limits

ES1 does not exceed the limits of ES 1 under

normal, abnormal, or single fault (not safeguard)

conditions.

If the source Voltage is less than the ES 1 Voltage

limits (under normal, abnormal, or single fault

conditions) the Current limit is undefined.

Likewise, if the Current is less than the ES 1 Current

limits (under normal, abnormal, or single fault

conditions) the Voltage limit is undefined.

MET Laboratories, Inc. MET Laboratories, Inc. MET Laboratories, Inc. MET Laboratories, Inc. First in Certification First in Certification First in Certification First in Certification | info@metlabs.com | www.metlabs.com

How – 62368 Energy LimitsEnergy Source 1 (ES 1); a class 1 electrical

energy source

• not exceeding ES 2 limits under single

fault conditions of a Basic safeguard

Under single fault conditions of a Basic

safeguard; if the source Voltage is less than

the ES 2 Voltage limits, the Current limit is

undefined

MET Laboratories, Inc. MET Laboratories, Inc. MET Laboratories, Inc. MET Laboratories, Inc. First in Certification First in Certification First in Certification First in Certification | info@metlabs.com | www.metlabs.com

How – 62368 Energy LimitsEnergy Source 1 (ES 1); a class 1 electrical

energy source

• not exceeding ES 2 limits under single

fault conditions of a Basic safeguard

Under single fault conditions of a Basic

safeguard; if the source Current is less than

the ES 2 Current limits, the Voltage limit is

undefined

MET Laboratories, Inc. MET Laboratories, Inc. MET Laboratories, Inc. MET Laboratories, Inc. First in Certification First in Certification First in Certification First in Certification | info@metlabs.com | www.metlabs.com

How – 62368 Energy LimitsEnergy Source 2 (ES 2);

A class 2 electrical energy source where:

• Both the touch voltage and the touch current exceed

the limits of ES 1; and,

• Under: Normal; Abnormal; and, Single fault conditions

either:

• the touch voltage does not exceed ES 2 Limits; or,

MET Laboratories, Inc. MET Laboratories, Inc. MET Laboratories, Inc. MET Laboratories, Inc. First in Certification First in Certification First in Certification First in Certification | info@metlabs.com | www.metlabs.com

How – 62368 Energy LimitsEnergy Source 2 (ES 2);

A class 2 electrical energy source where:

• Both the touch voltage and the touch current exceed

the limits of ES 1; and,

• Under: Normal; Abnormal; and, Single fault conditions

either:

• the touch voltage does not exceed ES 2 Limits; or,

• the touch current does not exceed ES 2 Limits

MET Laboratories, Inc. MET Laboratories, Inc. MET Laboratories, Inc. MET Laboratories, Inc. First in Certification First in Certification First in Certification First in Certification | info@metlabs.com | www.metlabs.com

How – 62368 Energy LimitsEnergy Source 3 (ES 3);

A class 3 electrical energy source

where BOTH the touch voltage

and the touch current exceed the

limits for ES 2

MET Laboratories, Inc. MET Laboratories, Inc. MET Laboratories, Inc. MET Laboratories, Inc. First in Certification First in Certification First in Certification First in Certification | info@metlabs.com | www.metlabs.com

How – 62368 Energy Limits

MET Laboratories, Inc. MET Laboratories, Inc. MET Laboratories, Inc. MET Laboratories, Inc. First in Certification First in Certification First in Certification First in Certification | info@metlabs.com | www.metlabs.com

How - 62368 Safeguards

• Products necessarily use energies capable of causing pain or injury

• Product design can’t eliminate it

MET Laboratories, Inc. MET Laboratories, Inc. MET Laboratories, Inc. MET Laboratories, Inc. First in Certification First in Certification First in Certification First in Certification | info@metlabs.com | www.metlabs.com

How - 62368 Safeguards

• There are many kinds of safeguards

– Equipment safeguards (Basic, Supplementary, Double, or Reinforced);

– Installation safeguards;

– Personal safeguards (requirements not addressed in 62368 – assumed present);

– Behavioral safeguards (Instructional, Precautionary, and Skill);

– Ordinary/Instructed person - service safeguards;

– Skilled person, equipment safeguards

MET Laboratories, Inc. MET Laboratories, Inc. MET Laboratories, Inc. MET Laboratories, Inc. First in Certification First in Certification First in Certification First in Certification | info@metlabs.com | www.metlabs.com

Electrically caused pain or injury

• Electrically caused pain or Injury

– A capable energy source;

– Transfer mechanism; and

– A body

MET Laboratories, Inc. MET Laboratories, Inc. MET Laboratories, Inc. MET Laboratories, Inc. First in Certification First in Certification First in Certification First in Certification | info@metlabs.com | www.metlabs.com

How – Bringing it all together - Ordinary

MET Laboratories, Inc. MET Laboratories, Inc. MET Laboratories, Inc. MET Laboratories, Inc. First in Certification First in Certification First in Certification First in Certification | info@metlabs.com | www.metlabs.com

How – Bringing it all together - Instructed

MET Laboratories, Inc. MET Laboratories, Inc. MET Laboratories, Inc. MET Laboratories, Inc. First in Certification First in Certification First in Certification First in Certification | info@metlabs.com | www.metlabs.com

How – Bringing it all together - Skilled

MET Laboratories, Inc. MET Laboratories, Inc. MET Laboratories, Inc. MET Laboratories, Inc. First in Certification First in Certification First in Certification First in Certification | info@metlabs.com | www.metlabs.com

62368 Who and When

• CB Scheme

– IEC 62368-1 2nd ed. was released in February of

2014

– Over 19 NCB’s from 14 countries are already

accredited to issue/recognize CB Reports/

Certificates

– 2 NCB’s are recognizing only

– 6 Countries have issued national differences

MET Laboratories, Inc. MET Laboratories, Inc. MET Laboratories, Inc. MET Laboratories, Inc. First in Certification First in Certification First in Certification First in Certification | info@metlabs.com | www.metlabs.com

62368 Who and When• European Union

– Has been published in the Official Journal

– And, a new corrigendum has been released

MET Laboratories, Inc. MET Laboratories, Inc. MET Laboratories, Inc. MET Laboratories, Inc. First in Certification First in Certification First in Certification First in Certification | info@metlabs.com | www.metlabs.com

62368 and the O.J.• Note 2.1: The new (or amended) standard

has the same scope as the superseded standard. On the date stated, the superseded standard ceases to give presumption of conformity with the essential or other requirements of the relevant Union legislation

– Therefore, to date, no dates of cessation have been published;

• No Group differences have been published

MET Laboratories, Inc. MET Laboratories, Inc. MET Laboratories, Inc. MET Laboratories, Inc. First in Certification First in Certification First in Certification First in Certification | info@metlabs.com | www.metlabs.com

62368 Who and When

• US/Canada

– Issued jointly

• ANSI/UL 62368-1-2014

• CAN/CSA C22.2 No. 62368-1-14

– Published December 1st, 2014

– DoW

• Also June 20, 2019

Baltimore, MD

410.354.3300

Union City, CA

510.489.6300

Santa Clara, CA

408.748.3585

Austin, TX

512.287.2500

Raleigh, NC

919.481.9319

Shenzhen, China

86.755.82911867

Seoul, Korea82.(0).2.2026.0191

Taiwan, R.O.C.

886.2.8227.8887

Europe

39.340.759.1189

OSHA NRTL Nationally Recognized Testing Laboratory

A2LA-Accredited to ISO/IEC 17025:2005 (Baltimore: #0591-01, Union City: #0591-02)

FCC TCB Telecommunications Certification Body

SCC CB Standards Council of Canada Certification Body

IECEE NCB National Certification Body

NVLAP-Accredited NIST CAB Conformity Assessment Body

Verizon ITL Independent Testing Laboratory

DSCC-Accredited for Designated MIL-STD Testing

EPCglobal Inc, Official Test Lab for RFID Hardware Certification Program

EPA- Recognized for ENERGY STAR® Testing & Certification

VCCI - Voluntary Council for Control of Interference (Japan)

ISTA Transit Tested Program Member - International Safe Transit Association

ACIL Member - American Council of Independent Laboratories

Measurement Canada Recognized Test Facility for electricity meters

Thank you!

Are there any questions?

MET Laboratories, Inc. MET Laboratories, Inc. MET Laboratories, Inc. MET Laboratories, Inc. First in Certification First in Certification First in Certification First in Certification | info@metlabs.com | www.metlabs.com