View
225
Download
0
Category
Preview:
Citation preview
8/10/2019 41-60Pages from Camfil Farr Product Catalog _product_catalogue_2008_en-gb-3.pdf
1/2039
P r e -
F i l t r a t
i o n
, C l a s s
G 3
t o
F 5
B a g a n
d
C o m p a c t
F i l t e r s
,
C l a s s
F 5
t o
F 9
H E P A
/ U L P A
F i l t e r s
, C l a s s
H 1
0
t o
U 1 7
C a r
b o n
a n
d
C h e m
i c a
l F i l t e r s
F i l t e r
F r a m e s a n
d
H o u s
i n g s
A i r F i l t e r
T e c
h n o
l o g y
C a m
f i l F a r r
S o
l u t
i o n sB a g a n d C o m p a c t F i l t e r s , C l a s s F 5 t o F 9
P l e a t e d C o m p a c t F i l t e r
Knowsley Road, Haslingden, Lancashire, BB4 4EG Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736
www.camfilfarr.co.uk A s p a r
t o f o u r c o n
t i n u o u s
i m p r o v e m e n
t , C a m
f i l F a r r r e s e r v e
t h e r i g h
t t o c h a n g e s p e c
i f i c a t
i o n s w
i t h o u
t n o t
i c e .
Riga-Flo
Advantages
Application: Air conditioning applications.Type: Rigid pleated filter.Case: Galvanised steel.Media: Glass fibre.EN 779:2002 efficiency: F5 (40-45%), F6 (55-65%), F7 (80-85%), F8 (90-95%).Eurovent 4/ 5 efficiency: EU5, EU6, EU7, EU8.Recommended final pressure drop: 450 Pa (suggested economical change point 250 Pa).Temperature: 70 C maximum in continuous service.Holding frames: Front and side access housings and frames are available.
W D
E F F I C I E N C Y G U A R A N T E E
Range of standard sizes Rigid design concept
High efficiency Suitable for turbulent airflow
Ref eren ce Type Model Di m ensi ons (WxHxD) m mFil ter c lassif icat ion EN779:2002Media surface
m2Air f low/presure drop at m3 /
h/PaUni t we igh t kgUnit volume m3
060558-007 Riga Flo Riga Flo 10 594x594x292 F5 5.4 3420/65 7.70 0.11
060558-012 Riga Flo Riga Flo 10 492x594x292 F5 4.4 2790/65 5.77 0.11
060558-008 Riga Flo Riga Flo 10 289x594x292 F5 2.6 1710/65 4.55 0.06
078367-007 Riga Flo Riga Flo 10 594x594x152 F5 2.7 2070/55 3.42 0.06
078367-016 Riga Flo Riga Flo 10 492x594x152 F5 2.2 1710/55 2.57 0.06
078367-008 Riga Flo Riga Flo 10 289x594x152 F5 1.3 990/55 2.21 0.03
060558-001 Riga Flo Riga Flo 15 594x594x292 F6 5.4 3420/70 7.70 0.11
060558-009 Riga Flo Riga Flo 15 492x594x292 F6 4.4 2790/70 5.77 0.11
060558-004 Riga Flo Riga Flo 15 289x594x292 F6 2.6 1710/70 4.55 0.06
078367-001 Riga Flo Riga Flo 15 594x594x152 F6 2.7 2070/65 3.42 0.06
078367-013 Riga Flo Riga Flo 15 492x594x152 F6 2.2 1710/65 2.57 0.06
078367-004 Riga Flo Riga Flo 15 289x594x152 F6 1.3 990/65 2.21 0.03
060558-002 Riga Flo Riga Flo 100 594x594x292 F7 5.4 3420/90 7.70 0.11
060558-010 Riga Flo Riga Flo 100 492x594x292 F7 4.4 2790/90 5.77 0.11
060558-005 Riga Flo Riga Flo 100 289x594x292 F7 2.6 1710/90 4.55 0.06
078367-002 Riga Flo Riga Flo 100 594x594x152 F7 2.7 2070/90 3.42 0.06
078367-014 Riga Flo Riga Flo 100 492x594x152 F7 2.2 1710/90 2.57 0.06
078367-005 Riga Flo Riga Flo 100 289x594x152 F7 1.3 990/90 2.21 0.03
060558-003 Riga Flo Riga Flo 200 594x594x292 F8 5.4 3420/130 7.70 0.11
060558-011 Riga Flo Riga Flo 200 492x594x292 F8 4.4 2790/130 5.77 0.11
060558-006 Riga Flo Riga Flo 200 289x594x292 F8 2.6 1710/130 4.55 0.06
078367-003 Riga Flo Riga Flo 200 594x594x152 F8 2.7 2070/175 3.42 0.06
078367-015 Riga Flo Riga Flo 200 492x594x152 F8 2.2 1710/175 2.57 0.06
078367-006 Riga Flo Riga Flo 200 289x594x152 F8 1.3 990/175 2.21 0.03
Other s izes are avai lable on request - PH version also avai lable (with header frame)
EN 779:2002
C E R
T I F I C A T E
I N D I V I D U A L L Y C E
R T I F
I E D
8/10/2019 41-60Pages from Camfil Farr Product Catalog _product_catalogue_2008_en-gb-3.pdf
2/20
B a g a n d C o m p a c t F i l t e r s , C l a s s F 5 t o F 9
40
P l e a t e d C o m p a c t F i l t e r
A s p a r
t o f o u r c o n
t i n u o u s
i m p r o v e m e n
t , C a m
f i l F a r r r e s e r v e
t h e r i g h
t t o c h
a n g e s p e c
i f i c a t
i o n s w
i t h o u
t n o t
i c e .
Knowsley Road, Haslingden, Lancashire, BB4 4EG Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736
www.camfilfarr.co.uk
OpakAir
Advantages
Application: High air flow air conditioning and process air applications.Type: High capacity compact filter.Case: Galvanised steel.Gasket: Half round EDPM.Media: Glass fibre paper.Separator: Hot-melt beads.Sealant: Polyurethane.EN 779:2002 efficiency: F8.Opacimetric efficiency: 95%.Recommended final pressure drop: 450 Pa (suggested economical change point 250 Pa).Temperature: 70 C maximum in continuous service.Mounting System: Front and side access housings and safechange systems are available.
W D
E F F I C I E N C Y G U A R A N T E E
Large surface area
U p to 6 0 0 0 m3 /hr air flow
Less frequent changes Low pressure drop
Ref erence Type Model Dimensions(WxHxD) mmFil ter c lass i f ica t ion
EN 779:2002Air f low/ pressure drop
m/hr /PaMedia
area m2Unit
weight kgUni t
volume m3
1514.13.05 OPAKAIR -95 OPR-E-F8 610x610x292 F8 4500/110 19,0 18,00 0,11
1514.53.05 OPAKAIR -95 OPR-E-F8 305x610x292 F8 2250/110 10,0 9,00 0,06
EN 779:2002
C E
R T I F I C A T E
I N D I V I D U A L L Y C E
R T I F I
E D
8/10/2019 41-60Pages from Camfil Farr Product Catalog _product_catalogue_2008_en-gb-3.pdf
3/2041
P r e -
F i l t r a t
i o n
, C l a s s
G 3
t o
F 5
B a g a n
d
C o m p a c t
F i l t e r s
,
C l a s s
F 5
t o
F 9
H E P A
/ U L P A
F i l t e r s
, C l a s s
H 1
0
t o
U 1 7
C a r
b o n
a n
d
C h e m
i c a
l F i l t e r s
F i l t e r
F r a m e s a n
d
H o u s
i n g s
A i r F i l t e r
T e c
h n o
l o g y
C a m
f i l F a r r
S o
l u t
i o n sB a g a n d C o m p a c t F i l t e r s , C l a s s F 5 t o F 9
P l e a t e d C o m p a c t F i l t e r
Knowsley Road, Haslingden, Lancashire, BB4 4EG Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736
www.camfilfarr.co.uk A s p a r
t o f o u r c o n
t i n u o u s
i m p r o v e m e n
t , C a m
f i l F a r r r e s e r v e
t h e r i g h
t t o c h
a n g e s p e c
i f i c a t
i o n s w
i t h o u
t n o t
i c e .
Airopac
Advantages
Application: Air conditioning applications and preparatory filtration in clean rooms.Type: High efficiency compact filter, HF model with header frame.Case: Galvanised steel.Media: Glass fibre paper.Separator: Hot-melt beads.Sealant: Polyurethane.EN 779:2002 efficiency: F7.Opacimetric efficiency: 85%.Recommended final pressure drop: 450 Pa (suggested economical change point 250 Pa).Temperature: 70 C maximum in continuous service.
Mounting system: Front and side access housing and frames are available, type 8, type L andFC housings.
W D
E F F I C I E N C Y G U A R A N T E E
Low pressure drop Robust metal header frame
High dust holding capacity
Large surface area Rigid design concept
Ref erence Type Model Dimensions(WxHxD) mmAir f low/nominal
pressure drop m/h/PaMedia area
m2Unit
weight kgUni t
volume m3EnergyRat ing
304215 Airopac-90 3GGM-24246-90 610x610x150 3600/105 12,3 6,8 0,06 B
304219 Airopac-90 3GGM-12246-90 305x610x150 1800/110 6,1 4,0 0,03 B
301732 Airopac-HF-90 3GGMHF-24245-90 592x592x135 3600/135 10,3 6,8 0,05 B301739 Airopac-HF-90 3GGMHF-12245-90 287x592x135 1800/160 4,5 3,8 0,02 B
8/10/2019 41-60Pages from Camfil Farr Product Catalog _product_catalogue_2008_en-gb-3.pdf
4/20
B a g a n d C o m p a c t F i l t e r s , C l a s s F 5 t o F 9
42
N o t e s
A s p a r
t o f o u r c o n
t i n u o u s
i m p r o v e m e n
t , C a m
f i l F a r r r e s e r v e
t h e r i g h
t t o c h
a n g e s p e c
i f i c a t
i o n s w
i t h o u
t n o t
i c e .
Knowsley Road, Haslingden, Lancashire, BB4 4EG Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736
www.camfilfarr.co.uk
8/10/2019 41-60Pages from Camfil Farr Product Catalog _product_catalogue_2008_en-gb-3.pdf
5/2043
P r e -
F i l t r a t
i o n
, C l a s s
G 3
t o
F 5
B a g a n
d
C o m p a c t
F i l t e r s
,
C l a s s
F 5
t o
F 9
H E P A
/ U L P A
F i l t e r s
, C l a s s
H 1
0
t o
U 1 7
C a r
b o n
a n
d
C h e m
i c a
l F i l t e r s
F i l t e r
F r a m e s a n
d
H o u s
i n g s
A i r F i l t e r
T e c
h n o
l o g y
C a m
f i l F a r r
S o
l u t
i o n sH E PA / U L PA F i l t e r s, C l a ss H 1 0 t o U 1 7
Knowsley Road, Haslingden, Lancashire, BB4 4EG Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736
www.camfilfarr.co.uk A s p a r
t o f o u r c o n
t i n u o u s
i m p r o v e m e n
t , C a m
f i l F a r r r e s e r v e
t h e r i g h
t t o c h
a n g e s p e c
i f i c a t
i o n s w
i t h o u
t n o t
i c e .
Summary HEPA / ULPA Filters, Class H10 to U17
Filters for High EfficiencySofilair - H10 to H14
Page 45
Filters for High EfficiencySofilair GreenPage 46
Filters for High EfficiencyClose Pleat - H13
Page 47
Filters for High EfficiencyOpakfil G Micretain - H10
Page 4 8
HEPA/ ULPA PanelsMegalam MD, MX, MG
Page 49
HEPA/ULPA PanelsMegalam MX & MG - H14
Page 50
HEPA/ ULPA PanelsMegalam MD - H10 & H14
Page 51
HEPA/ULPA PanelsMegalam MD & MG - U15
Page 52
HEPA/ ULPA PanelsMegalam (Laminator) MDL &
MXL - U15 & U16Page 53
HEPA/ULPA PanelsSilent Hood Diffuser - H14
Page 54
HEPA/ ULPA PanelsMegalam U (Gel) - H14 & U15
Page 55
HEPA/ULPA PanelsMegalam T (Gel) - H14 & U15
Page 56
HEPA/ ULPA PanelsMegalam MD & MX e-PTFE -
U15Page 57
8/10/2019 41-60Pages from Camfil Farr Product Catalog _product_catalogue_2008_en-gb-3.pdf
6/20
H E PA / U L PA F i l t e rs , C l a ss H 1 0 t o U 1 7
44
E u r o p e a n S t a n d a r d E N 1 8 2 2
A s p a r
t o f o u r c o n
t i n u o u s
i m p r o v e m e n
t , C a m
f i l F a r r r e s e r v e
t h e r i g h
t t o c h
a n g e s p e c
i f i c a t
i o n s w
i t h o u
t n o t
i c e .
Knowsley Road, Haslingden, Lancashire, BB4 4EG Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736
www.camfilfarr.co.uk
All H EPA / U LPA filters produced byCamfil are supplied fully in accordancewith the European Standard EN 1822
SOFILAIR and M EGALAM what you canexpect: 100% control of everything weproduce.
Qualifi ed personnel responsible for te sting. Unique serial number for each filter. Clear, unambi guous control procedures specifying test
conditions, target values and actual performance ofour filters.
Complete traceability of materials and operations. Equipment and systems certified by accredited
bodies. Tested performance verified by installation testing
and validation.
The CAMFIL extra: Individual test results are recorded on a unique
product label. The label has a detachable copy whichcan be used to record the position of the individualfilters within your process.
It can also be used as part of the validation processensuring regulatory compliance of your installati on.
In shor t EN 1822 means:
Individually cert if ied f i l ters Tested using MPPS (Most Penetrating Particle Size)
challenge. Explicit, standardised test procedures. Full traceability of materials and test data. NB: the f i l te r grades EU1 3 e tc , a re incompat ib le wi th
EN 1 8 2 2 .
EN1822N 8
8/10/2019 41-60Pages from Camfil Farr Product Catalog _product_catalogue_2008_en-gb-3.pdf
7/2045
P r e -
F i l t r a t
i o n
, C l a s s
G 3
t o
F 5
B a g a n
d
C o m p a c t
F i l t e r s
,
C l a s s
F 5
t o
F 9
H E P A
/ U L P A
F i l t e r s
, C l a s s
H 1
0
t o
U 1 7
C a r
b o n
a n
d
C h e m
i c a
l F i l t e r s
F i l t e r
F r a m e s a n
d
H o u s
i n g s
A i r F i l t e r
T e c
h n o
l o g y
C a m
f i l F a r r
S o
l u t
i o n sH E PA / U L PA F i l t e r s, C l a ss H 1 0 t o U 1 7
F i l t e r s f o r H i g h E f f i c i e n c y
Knowsley Road, Haslingden, Lancashire, BB4 4EG Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736
www.camfilfarr.co.uk A s p a r
t o f o u r c o n
t i n u o u s
i m p r o v e m e n
t , C a m
f i l F a r r r e s e r v e
t h e r i g h
t t o c h
a n g e s p e c
i f i c a t
i o n s w
i t h o u
t n o t
i c e .
Sof i lai r - H1 0 to H 1 4
Advantages
Application: Very high efficiency final filtration in air conditioning systems, housings anddiffusers.Type: High air flow HEPA filter.Frame: Galvanised steel.Media: Glass fibre paper.Separator: Hot-melt beads.Sealant: Polyurethane.Gasket: One piece half round continuous gasket.EN 1 8 22 efficiency: H10, H12, H13, and H14.MPPS efficiency: H10:>85%, H12:>99.5%, H13:>99.95%, H14:> 99.995%.Recommended final pressure drop: 600 Pa.Maximum air flow rate: See table, use nominal values otherwise a reduction in efficiency mayoccur.Temperature: 80 C maximum in continuous service.Mounting systems: Front and side access filter frames, FC Housings, terminal housings andsafe change systems.
W D
High air f low rates, up to 5000m 3 /hr
Tested in accordance withE N 1 8 2 2
Ne w ergonomic handl e t o assistwith filter changes
Low pressure drop
Ref erence Type Model Dimensions(WxHxD) mmFil ter c lass i f i ca t ion
EN 1822Media
area m3Air flow/preassure
drop m3 / h / PaUni t
weight kgUni t
volume m3
1575.02.00 Sofilair H10 SFR-E-2000-H10 305x610x292 H10 14 2000/230 8 0,06
1573.02.00 Sofilair H10 SFR-E-4000-H10 610x610x292 H10 21 4000/230 13 0,11
1570.01.00 Sofilair H10 SFR-E-5000-H10 610x610x292 H10 35 5000/230 16,5 0,111585.01.00 Sofilair H12 SFR-E-1500-H12 305x610x292 H12 16 1500/250 8,5 0,06
1580.01.00 Sofilair H12 SFR-E-3400-H12 610x610x292 H12 33 3400/250 16,5 0,11
1580.02.00 Sofilair H12 SFR-E-4000-H12 610x610x292 H12 40 4000/250 16,5 0,11
1568.01.00 Sofilair H13 SFR-E-1300-H13 289x595x292 H13 16 1300/250 8,5 0,06
1565.01.00 Sofilair H13 SFR-E-1500-H13 305x610x292 H13 16 1500/250 8,5 0,06
1567.01.00 Sofilair H13 SFR-E-3200-H13 595x595x292 H13 38 3200/250 15,5 0,11
1560.01.00 Sofilair H13 SFR-E-3400-H13 610x610x292 H13 33 3400/250 16,5 0,11
1560.02.00 Sofilair H13 SFR-E-4000-H13 610x610x292 H13 40 4000/250 16,5 0,11
1560.02.20 Sofilair H13 SFR-E-5000-H13 610x610x292 H13 40 5000/400 16,5 0,11
1565.01.02 Sofilair H14 SFR-E-1400-H14 610x305x292 H14 16 1400/280
1500/310* 8,5 0,06
1560.02.06 Sofilair H14 SFR-E-3500-H14 610x610x292 H14 40 3500/270
4000/310* 16,5 0,11
*Maximum airflow
EN1822N 8
8/10/2019 41-60Pages from Camfil Farr Product Catalog _product_catalogue_2008_en-gb-3.pdf
8/20
H E PA / U L PA F i l t e rs , C l a ss H 1 0 t o U 1 7
46
F i l t e r s f o r H i g h E f f i c i e n c y
A s p a r
t o f o u r c o n
t i n u o u s
i m p r o v e m e n
t , C a m
f i l F a r r r e s e r v e
t h e r i g h
t t o c h
a n g e s p e c
i f i c a t
i o n s w
i t h o u
t n o t
i c e .
Knowsley Road, Haslingden, Lancashire, BB4 4EG Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736
www.camfilfarr.co.uk
Sofilair Green
Advantages
Application: High efficiency final filtration in air conditioning systems, extraction from corrosiveor hazardous environments.Type: High air flow incinerable HEPA filter.Frame: ABS.Media: Glass fibre paper.Separator: Hot-melt beads.Sealant: Polyurethane.Gasket: One piece half round continuous gasket.EN 1 8 22 efficiency: H10, H12, H13, H14.MPPS efficiency: H10:>85%, H13:>99.95 & H14:>99.995%.Recommended final pressure drop: 600 Pa.Maximum air flow rate: See table, use nominal values otherwise a reduction in efficiency mayoccur.Temperature: 60 C maximum in continuous service.Mounting systems: Front and side access filter frames. Terminal housings and safe changesystems.
W D
Totally incinerable High air flow rates Light weight construction
Ne w ergonomic handl e to assistwith filter changes
Corrosion resista nt
Reference Type ModelDimensions
(LxHxD)mm
Filterc lass i f ica t ion
EN 1822
Media aream2
Airflow/pressured rop m3 / h / Pa
Uni tweight
kg
Uni tvolume
m3
1575.82.00 Sofilair Green H10 SFRG-P-2000-H10 305x610x292 H10 13 2000/230 6 0,06
1570.81.00 Sofilair Green H10 SFRG-P-5000-H10 610x610x292 H10 33 5000/230 12 0,11
1585.81.00 Sofilair Green H12 SFRG-P-1500-H12 305x610x292 H12 15 1500/250 10 0,061580.82.00 Sofilair Green H12 SFRG-P-4000-H12 610x610x292 H12 38 4000/250 13,5 0,11
1565.81.00 Sofilair Green H13 SFRG-P-1500-H13 305x610x292 H13 15 1500/250 6 0,06
1560.82.00 Sofilair Green H13 SFRG-P-4000-H13 610x610x292 H13 38 4000/250 12 0,11
1565.81.02 Sofilair Green H14 SFRG-P-1400-H14 305x610x292 H14 15 1400/280
1500/310* 6 0,06
1560.82.06 Sofilair Green H14 SFRG-P-3500-H14 610x610x292 H14 38 3500/270
4000/310* 12 0,11
EN1822N 8
8/10/2019 41-60Pages from Camfil Farr Product Catalog _product_catalogue_2008_en-gb-3.pdf
9/2047
P r e -
F i l t r a t
i o n
, C l a s s
G 3
t o
F 5
B a g a n
d
C o m p a c t
F i l t e r s
,
C l a s s
F 5
t o
F 9
H E P A
/ U L P A
F i l t e r s
, C l a s s
H 1
0
t o
U 1 7
C a r
b o n
a n
d
C h e m
i c a
l F i l t e r s
F i l t e r
F r a m e s a n
d
H o u s
i n g s
A i r F i l t e r
T e c
h n o
l o g y
C a m
f i l F a r r
S o
l u t
i o n sH E PA / U L PA F i l t e r s, C l a ss H 1 0 t o U 1 7
F i l t e r s f o r H i g h E f f i c i e n c y
Knowsley Road, Haslingden, Lancashire, BB4 4EG Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736
www.camfilfarr.co.uk A s p a r
t o f o u r c o n
t i n u o u s
i m p r o v e m e n
t , C a m
f i l F a r r r e s e r v e
t h e r i g h
t t o c h
a n g e s p e c
i f i c a t
i o n s w
i t h o u
t n o t
i c e .
Close Pleat - H13
Advantages
Application: Very high efficiency final filtration in air conditioning systems, housings, ducts anddiffusers.Type: Close pleated very high efficiency filter.Frame: Galvanised steel / MDF.Gasket: Half round continuous expanded polyurethane.Media: Pleated glass paper.Separator: Hot melt beads.Sealant: Polyurethane.EN 1 8 22 efficiency: H13.MPPS efficiency: 99.95%.DOP efficiency 0.3 m: 99.99%.Recommended final pressure drop: 600 Pa.Maximum flow rate: See table, use nominal values otherwise a reduction in efficiency mayoccur.Temperature: 70 C maximum in continuous service.Mounting systems: FCB Housings, Ducts, Diffusers, CAMSAFE.
W D
Range of standard sizes Compact design concept
Very high efficiency
Ref erence Type Model Dimensions(WxHxD) mmFil ter c lass i f ica t ion
EN 1822Air f low/pressure drop
m/hr /PaMed ia a rea
m2Unit
weight kgUni t
volume m3
229004A1 Steel case HEPA TREA-1000 610x610x292 H13 2700 / 250 23,5 13 0,13
229002A1 Steel case HEPA TREA-450 305x610x292 H13 1350 / 250 11,7 7 0,07
231007A1 Steel case HEPA MXEA-600 610x610x150 H13 1625 / 250 13,4 12 0,07
231004A1 Steel case HEPA MXEA-220 305x610x150 H13 820 / 250 6,7 6 0,04
226001A1 MDF case HEPA TRSA-1000 610x610x292 H13 2450 / 250 21,4 13 0,13
226003A1 MDF case HEPA TRSA-450 305x610x292 H13 1160 / 250 10,1 7 0,07
225006A1 MDF case HEPA MXSA-600 610x610x150 H13 1475 / 250 12,1 12 0,07
225007A1 MDF case HEPA MXSA-220 305x610x150 H13 690 / 250 5,7 6
Alternative models, sizes and constructions are available.
EN1822N 8
8/10/2019 41-60Pages from Camfil Farr Product Catalog _product_catalogue_2008_en-gb-3.pdf
10/20
H E PA / U L PA F i l t e rs , C l a ss H 1 0 t o U 1 7
48
F i l t e r s f o r H i g h E f f i c i e n c y
A s p a r
t o f o u r c o n
t i n u o u s
i m p r o v e m e n
t , C a m
f i l F a r r r e s e r v e
t h e r i g h
t t o c h
a n g e s p e c
i f i c a t
i o n s w
i t h o u
t n o t
i c e .
Knowsley Road, Haslingden, Lancashire, BB4 4EG Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736
www.camfilfarr.co.uk
Opakfil G Micretain - H10
Advantages
Application: Final filtration in air conditioning systems, industrial processes.Type: Very high efficiency, incinerable, compact filter.Frame: 25 mm thick flange, polypropylene and ABS.Gasket: Half round continuous expanded polyurethane. Position: 01- rear, 10- front.Media: Glass fibre paper.Separator: Hot-melt beads.Sealant: Polyurethane.EN 1 8 22 efficiency: H10.MPPS efficiency: 85%.Recommended final pressure drop: 450 Pa.Maximum flow rate: See table, use nominal values otherwise a reduction in efficiency mayoccur.Temperature: 70 C maximum in continuous service.Holding Frames: Front and side access housings and frames are available. Type 8, Type L andFC housings.
W D
Easy to install Incinerable
U p to 4 0 0 0 m3 /hr air flow
Ref erence Type Model Dimensions(WxHxD) mmFilter
c lass i f ica t ion EN1822
Mediaarea m2
Air f low /pressure drop
m3 / h r/ Pa
Uni tweight
kg
Uni tvolume
m3
1511.36.51 70PGHF-241212 Opakfil-G Micretain 592x287x290-01 H10 9.0 1700/250 3 0.06
1511.35.51 70PGHF-242412 Opakfil-G Micretain 592x592x290-01 H10 19.0 4000/250 6 0.11
1511.36.52 70PGHF-241212 Opakfil-G Micretain 592x287x290-10 H10 9.0 1700/250 3 0.06
1511.35.52 70PGHF-242412 Opakfil-G Micretain 592x592x290-10 H10 19.0 4000/250 6 0.11
8/10/2019 41-60Pages from Camfil Farr Product Catalog _product_catalogue_2008_en-gb-3.pdf
11/2049
P r e -
F i l t r a t
i o n
, C l a s s
G 3
t o
F 5
B a g a n
d
C o m p a c t
F i l t e r s
,
C l a s s
F 5
t o
F 9
H E P A
/ U L P A
F i l t e r s
, C l a s s
H 1
0
t o
U 1 7
C a r
b o n
a n
d
C h e m
i c a
l F i l t e r s
F i l t e r
F r a m e s a n
d
H o u s
i n g s
A i r F i l t e r
T e c
h n o
l o g y
C a m
f i l F a r r
S o
l u t
i o n sH E PA / U L PA F i l t e r s, C l a ss H 1 0 t o U 1 7
H E PA / U L PA P a n e l s
Knowsley Road, Haslingden, Lancashire, BB4 4EG Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736
www.camfilfarr.co.uk A s p a r
t o f o u r c o n
t i n u o u s
i m p r o v e m e n
t , C a m
f i l F a r r r e s e r v e
t h e r i g h
t t o c h
a n g e s p e c
i f i c a t
i o n s w
i t h o u
t n o t
i c e .
M egalam MD, M X, M G
Advantages
W D
Less pressure drop Quieter
Longer operating lif e Higher flow rate
Example: Megalam H14 / 6P6
MD MX MG
Filter area 10m 2 12.5m 2 18m 2
Pressure drop 0.45 m/s (600m 3/h) 120 Pa 90 Pa (-25%) 70 Pa (-40%)
Maximum pressure drop 900 m 3/h (190 Pa) 600 m 3/h (90 Pa) 2000 m 3/h (250 Pa)
Energy -25% -42%
Lifespan x 1.5 x 2.5
Less pressure loss More Flow
Lower pressure dropHigher air ow rateMore energy savingsLonger operating life
EN1822N 8
8/10/2019 41-60Pages from Camfil Farr Product Catalog _product_catalogue_2008_en-gb-3.pdf
12/20
H E PA / U L PA F i l t e rs , C l a ss H 1 0 t o U 1 7
50
H E PA / U L PA P a n e l s
A s p a r
t o f o u r c o n
t i n u o u s
i m p r o v e m e n
t , C a m
f i l F a r r r e s e r v e
t h e r i g h
t t o c h
a n g e s p e c
i f i c a t
i o n s w
i t h o u
t n o t
i c e .
Knowsley Road, Haslingden, Lancashire, BB4 4EG Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736
www.camfilfarr.co.uk
M egalam M X & M G - H 1 4
Advantages
Application: Final or return filtration for clean rooms with turbulent flow.Type: HEPA filtering panel withseal for mechanical clamping systems.Frame: Extruded and anodised aluminium.Gasket: Half round continuous expanded polyurethane.Media: Glass fibre paper.Separator: Hot-melt beads.Sealant: Polyurethane.Grid: Mild steel painted grille upstream and downstream.EN 1 8 22 efficiency: H14.MPPS efficiency: 99.995%.Recommended final pressure drop: 600 Pa.Maximum flow rate: see table, use nominal values otherwise a reduction in efficiency mayoccur.Temperature: 70 C maximum in continuous service.Test: 100%individually scanned to EN 1822.Mounting system: Mechanical clamping structure, Terminal housing.
W D
Low pressure drop Quiet : LW = 3 5 dB Higher flow rate
Longer operating li fe Individually scanned in
accordance wi th EN 1 8 2 2
Ref erence Type Model Dimensions(WxHxD) mm
Filterc lass i f ica
tion EN1822
Me dia
aream2
Air flow/pressured rop m / sm3 / h / Pa
Air f low/pressuredrop maxm3 / h / Pa
Uni tweigh t kg
Uni tvolum em3
3440.00.20 MEGALAM MXA 3P6 305x610x90 H14 6.3 300/90 650/195 3.0 0.02
3440.00.30 MEGALAM MXA 6P6 610x610x90 H14 12.7 600/90 1300/195 6.0 0.05
3440.00.40 MEGALAM MXA 9P6 915x610x90 H14 19.1 900/90 1950/195 9.0 0.05
3440.00.50 MEGALAM MXA 12P6 1220x610x90 H14 28.3 1200/90 2500/195 12.0 0.07
3444.00.20 MEGALAM MGA 3P6 305x610x110 H14 9.8 300/70 1000/220 5.0 0.02
3444.00.30 MEGALAM MGA 6P6 610x610x110 H14 19.8 600/70 2000/220 8.0 0.04
3444.00.40 MEGALAM MGA 9P6 915x610x110 H14 27.0 900/70 3000/220 10.0 0.06
3444.00.50 MEGALAM MGA 12P6 1220x610x110 H14 36.3 1200/70 4000/220 13.0 0.08
Other d imensions avai lable on reques t - Also avai lable wi th laminat or
EN1822N 8
8/10/2019 41-60Pages from Camfil Farr Product Catalog _product_catalogue_2008_en-gb-3.pdf
13/2051
P r e -
F i l t r a t
i o n
, C l a s s
G 3
t o
F 5
B a g a n
d
C o m p a c t
F i l t e r s
,
C l a s s
F 5
t o
F 9
H E P A
/ U L P A
F i l t e r s
, C l a s s
H 1
0
t o
U 1 7
C a r
b o n
a n
d
C h e m
i c a
l F i l t e r s
F i l t e r
F r a m e s a n
d
H o u s
i n g s
A i r F i l t e r
T e c
h n o
l o g y
C a m
f i l F a r r
S o
l u t
i o n sH E PA / U L PA F i l t e r s, C l a ss H 1 0 t o U 1 7
H E PA / U L PA P a n e l s
Knowsley Road, Haslingden, Lancashire, BB4 4EG Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736
www.camfilfarr.co.uk A s p a r
t o f o u r c o n
t i n u o u s
i m p r o v e m e n
t , C a m
f i l F a r r r e s e r v e
t h e r i g h
t t o c h
a n g e s p e c
i f i c a t
i o n s w
i t h o u
t n o t
i c e .
M egal am M D - H 1 0 & H 1 4
Advantages
Application: Final or return filtration for clean rooms with turbulent flow.Type: HEPA filtering panel with seal for mechanical clamping mounting systems.Frame: Extruded and anodised aluminium.Gasket: Half round continuous expanded polyurethane.Media: Glass fibre paper.Separator: Hot-melt beads.Sealant: Polyurethane.Grid: Mild steel painted grille upstream and downstream.EN 1 8 22 efficiency: H10 / H14.MPPS efficiency: H10: 85%, H14: 99.995%.DOP efficiency: H10: 95%, H14: 99.999%.Recommended final pressure drop: 600 Pa.Maximum flow rate: See table, use nominal values otherwise a reduction in efficiency mayoccur.Temperature: 70 C maximum in continuous service.Test: : 100%individually scanned to EN 1822.Mounting system: Mechanical clamping structure, Terminal housings.
W D
Low pressure drop Protection via 2 grids
Guaranteed performance
Ref erence Type Model Dimensions(WxHxD) mmFilter
classification EN1822
Mediaa rea m2
Air flow / pressuredrop a t 0 .45 m/s
m3 / h / Pa
Uni tweight
kg
Uni tvolume
m3
3401.61.11 MEGALAM MDM 3P6 305x610x66 H10 4.6 300/70 2.0 0.02
3401.62.08 MEGALAM MDM 6P6 610x610x66 H10 9.3 600/70 4.0 0.03
3401.63.01 MEGALAM MDM 9P6 915x610x66 H10 14.0 900/70 6.0 0.053401.64.07 MEGALAM MDM 12P6 1220x610x66 H10 18.5 1200/70 9.0 0.07
3423.00.10 MEGALAM MDA 3P3 305x305x66 H14 2.4 150/140 1.0 0.01
3423.00.20 MEGALAM MDA 3P6 305x610x66 H14 4.8 300/130 3.0 0.02
3423.00.30 MEGALAM MDA 6P6 610x610x66 H14 10.0 600/120 5.0 0.03
3423.00.90 MEGALAM MDA 7P6 762x610x66 H14 12.3 750/120 5.0 0.04
3423.00.40 MEGALAM MDA 9P6 915x610x66 H14 14.8 900/120 6.0 0.05
3423.00.50 MEGALAM MDA 12P6 1220x610x66 H14 19.8 1200/120 9.0 0.07
3423.00.60 MEGALAM MDA 15P6 1525x610x66 H14 24.9 1500/120 10.0 0.07
3423.01.00 MEGALAM MDA 9P7 915x762x66 H14 18.6 1125/120 7.5 0.06
3423.01.10 MEGALAM MDA 12P7 1220x762x66 H14 24.9 1500/120 10.0 0.07
3423.01.20 MEGALAM MDA 15P7 1525x762x66 H14 31.0 1875/120 12.5 0.09
3423.01.30 MEGALAM MDA 18P7 1830x762x66 H14 37.2 2250/120 12.5 0.12
3423.01.40 MEGALAM MDA 3P9 305x915x66 H14 7.4 450/120 3.0 0.03
3423.01.50 MEGALAM MDA 9P9 915x915x66 H14 22.3 1350/120 9.0 0.06
3423.01.60 MEGALAM MDA 12P9 1220x915x66 H14 30.0 1800/120 12.0 0.08
Other dimensions available on request
EN1822N 8
8/10/2019 41-60Pages from Camfil Farr Product Catalog _product_catalogue_2008_en-gb-3.pdf
14/20
H E PA / U L PA F i l t e rs , C l a ss H 1 0 t o U 1 7
52
H E PA / U L PA P a n e l s
A s p a r
t o f o u r c o n
t i n u o u s
i m p r o v e m e n
t , C a m
f i l F a r r r e s e r v e
t h e r i g h
t t o c h
a n g e s p e c
i f i c a t
i o n s w
i t h o u
t n o t
i c e .
Knowsley Road, Haslingden, Lancashire, BB4 4EG Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736
www.camfilfarr.co.uk
M egalam MD & M G - U1 5
Advantages
Application: Final or return filtration for clean rooms with turbulent flow.Type: ULPA filtering panel withseal for mechanical clamping systems.Frame: Extruded and anodised aluminium.Gasket: Half round continuous expanded polyurethane.Media: Glass fibre paper.Separator: Hot-melt beads.Sealant: Polyurethane.Grid: Mild steel painted grille upstream and downstream.EN 1 8 22 efficiency: U15.MPPS efficiency: 99.9995%.Recommended final pressure drop: 600 Pa.Maximum flow rate: See table, use nominal values otherwise a reduction in efficiency mayoccur.Temperature: 70 C maximum in continuous service.Test: 100%individually scanned to EN 1822.Mounting system: Mechanical clamping structure, Terminal housings.
W D
Guaranteed performance 100% individual scanning test
according to standard EN 1822
Protection via 2 grids Very high efficiency
Ref erence Type Model Dimensions(WxHxD) mmFil ter c lass i f ica t ion
EN 1822Media
area m2Air flow /
pressure dropm3 / hr / Pa
Uni tweight
kg
Uni tvolume
m3
3445.00.30 MEGALAM MGGS 6P6 610x610x110 U15 8.0
3418.00.10 MEGALAM MDGS 3P3 305x305x66 U15 2,8 150/140 1.0 0,01
3418.00.20 MEGALAM MDGS 3P6 305x610x66 U15 5,5 300/140 2.0 0,023418.00.30 MEGALAM MDGS 6P6 610x610x66 U15 11,2 600/140 4.0 0,03
3418.00.90 MEGALAM MDGS 7P6 762x610x66 U15 14 750/140 5.0 0,04
3418.00.40 MEGALAM MDGS 9P6 915x610x66 U15 16,9 900/140 6.0 0,05
3418.00.50 MEGALAM MDGS 12P6 1220x610x66 U15 22,5 1200/140 8.0 0,07
3418.00.60 MEGALAM MDGS 15P6 1525x610x66 U15 28,3 1500/140 10.0 0,07
3418.00.80 MEGALAM MDGS 3P7 305x762x66 U15 7 375/140 2.5 0,02
3418.01.00 MEGALAM MDGS 9P7 915x762x66 U15 21,1 1125/140 7.5 0,06
3418.01.10 MEGALAM MDGS 12P7 1220x762x66 U15 28,3 1500/140 10.0 0,07
3418.01.20 MEGALAM MDGS 15P7 1525x762x66 U15 35,3 1875/140 12.5 0,09
3418.01.40 MEGALAM MDGS 3P9 305x915x66 U15 8,3 450/140 3.0 0,03
3418.01.50 MEGALAM MDGS 9P9 915x915x66 U15 25,3 1350/140 9.0 0,06
3418.01.60 MEGALAM MDGS 12P9 1220x915x66 U15 33,9 1800/140 12.0 0,08
EN1822N 8
8/10/2019 41-60Pages from Camfil Farr Product Catalog _product_catalogue_2008_en-gb-3.pdf
15/2053
P r e -
F i l t r a t
i o n
, C l a s s
G 3
t o
F 5
B a g a n
d
C o m p a c t
F i l t e r s
,
C l a s s
F 5
t o
F 9
H E P A
/ U L P A
F i l t e r s
, C l a s s
H 1
0
t o
U 1 7
C a r
b o n
a n
d
C h e m
i c a
l F i l t e r s
F i l t e r
F r a m e s a n
d
H o u s
i n g s
A i r F i l t e r
T e c
h n o
l o g y
C a m
f i l F a r r
S o
l u t
i o n sH E PA / U L PA F i l t e r s, C l a ss H 1 0 t o U 1 7
H E PA / U L PA P a n e l s
Knowsley Road, Haslingden, Lancashire, BB4 4EG Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736
www.camfilfarr.co.uk A s p a r
t o f o u r c o n
t i n u o u s
i m p r o v e m e n
t , C a m
f i l F a r r r e s e r v e
t h e r i g h
t t o c h
a n g e s p e c
i f i c a t
i o n s w
i t h o u
t n o t
i c e .
M egalam (Laminator) M DL & M XL - U 1 5 & U 1 6
Advantages
Application: Final filtration for clean rooms, clean devices and units with laminar flow.Type: ULPA filtering panel with laminator and gasket for mechanical clamping systems.Frame: Extruded and anodised aluminium.Gasket: Half round continuous expanded polyurethane.Media: Glass fibre paper.Separator: Hot-melt beads.Sealant: Polyurethane.Laminator: Screen bonded downstream for laminar diffusion.Grid: Mild steel painted grille placed upstream.EN 1 8 22 efficiency: U15 / U16.MPPS efficiency: U15: 99.9995%, U16: 99.99995%.Recommended final pressure drop: 600 Pa.Maximum flow rate: See table, use nominal values otherwise a reduction in efficiency mayoccur.Temperature: 70 C maximum in continuous service.Test: 100%individually scanned to EN 1822.Mounting system: Mechanical clamping structure, Terminal housings.
W D
Laminarity better than +/- 20% 100% individual scanning test
according to standard EN 1822
Integrated laminator screen ULPA U15 and U16
Ref erence Type Model Dimensions(WxHxD) mmFilter
c lass i f ica t ion EN1822
Mediaarea m
Air f low/pressured r op m / h/ Pa
Un i t w ei g h tkg
Uni tvolume
m3
3449.20.40 MEGALAM MDLGS 9P6-01 915x610x66 U15 16.9 900/150 6.0 0.05
3449.00.40 MEGALAM MDLGS 9P6-10 915x610x66 U15 16.9 900/150 6.0 0.05
3449.20.50 MEGALAM MDLGS 12P6-01 1220x610x66 U15 22.5 1200/150 8.0 0.07
3449.00.50 MEGALAM MDLGS 12P6-10 1220x610x66 U15 22.5 1200/150 8.0 0.07
3450.20.40 MEGALAM MDLSGS 9P6-01 915x610x66 U16 18.4 900/165 6.0 0.05
3450.00.40 MEGALAM MDLSGS 9P6-10 915x610x66 U16 18.4 900/165 6.0 0.05
3450.00.50 MEGALAM MDLSGS 12P6-01 1220x610x66 U16 24.5 1200/165 8.0 0.07
3450.20.50 MEGALAM MDLSGS 12P6-01 1220x610x66 U16 24.5 1200/165 8.0 0.07
3425.20.30 MEGALAM MXLGS 6P6-01 610x610x90 U15 15.4 600/120 5.6 0.05
3425.00.30 MEGALAM MXLGS 6P6-10 610x610x90 U15 15.4 600/120 5.6 0.05
Other dimensions available on request
EN1822N 8
8/10/2019 41-60Pages from Camfil Farr Product Catalog _product_catalogue_2008_en-gb-3.pdf
16/20
H E PA / U L PA F i l t e rs , C l a ss H 1 0 t o U 1 7
54
H E PA / U L PA P a n e l s
A s p a r
t o f o u r c o n
t i n u o u s
i m p r o v e m e n
t , C a m
f i l F a r r r e s e r v e
t h e r i g h
t t o c h
a n g e s p e c
i f i c a t
i o n s w
i t h o u
t n o t
i c e .
Knowsley Road, Haslingden, Lancashire, BB4 4EG Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736
www.camfilfarr.co.uk
Silent H ood Diffuser - H 1 4
Advantages
Application: Final filtration for clean rooms.Type: Ready to install HEPA/ULPA filter diffuser.Frame: Extruded and anodised aluminium, galvanised steel cover.Gasket: 10x5mm neoprene, self adhesive ready for installation.Media: Glass fibre paper.Separator: Hot melt beads.Sealant: Polyurethane.Connection: Spigot with outer dia. 315mm or 250mm depending on the model.Grid: Downstream in painted mild steel.EN 1 8 22 efficiency: H14.MPPS efficiency: 99.995%.Recommended final pressure drop: 600 Pa.Maximum flow rate: See table, use nominal values otherwise a reduction in efficiency mayoccur.Temperature: 70 C maximum in continuous service.Test: 100%individually scanned in accordance with EN 1822.Mounting system: Mechanical clamping structures.
H14 compact f i l ter-diffuser forclean room
Ready to install
Quiet : LW = 3 5 dB Laminar i ty +/ - 2 0 %
Ref erence Type Model Dimensions (WxHxD)m mFil ter c lass i f ica t ion
EN 1822media
area m2Air f low/nominal
pressure dropm/h/Pa
Uni tweight kg
Uni t volumem3
5970.00.21 Silent Hood MDSHA RF1 300x600x116/250 H14 4.2 300/140 10 0.03
5975.00.31 Silent Hood MDSHA RF1 600x600x116/315 H14 9.2 600/140 13 0.06
5975.00.41 Si lent Hood MDSHA RF 905x600x116/335 H14 14 900/140 16 0.09
5975.00.51 Silent Hood MDSHA RF1 1210x600x116/315 H14 19 1200/140 19 0.13
5975.00.20 Silent Hood MDSHA RF1 305x610x116/250 H14 4.3 300/140 10 0.03
5975.00.30 Silent Hood MDSHA RF1 610x610x116/315 H14 9.4 600/140 13 0.06
5975.00.40 Silent Hood MDSHA RF 915x610x116/315 H14 14.6 900/140 16 0.09
5975.00.50 Silent Hood MDSHA RF 1220x610x116/315 H14 19.5 1200/140 19 0.13
Other d imensions avai lable on reques t . Avai lable in o ther grades and wi th a lam inator
8/10/2019 41-60Pages from Camfil Farr Product Catalog _product_catalogue_2008_en-gb-3.pdf
17/2055
P r e -
F i l t r a t
i o n
, C l a s s
G 3
t o
F 5
B a g a n
d
C o m p a c t
F i l t e r s
,
C l a s s
F 5
t o
F 9
H E P A
/ U L P A
F i l t e r s
, C l a s s
H 1
0
t o
U 1 7
C a r
b o n
a n
d
C h e m
i c a
l F i l t e r s
F i l t e r
F r a m e s a n
d
H o u s
i n g s
A i r F i l t e r
T e c
h n o
l o g y
C a m
f i l F a r r
S o
l u t
i o n sH E PA / U L PA F i l t e r s, C l a ss H 1 0 t o U 1 7
H E PA / U L PA P a n e l s
Knowsley Road, Haslingden, Lancashire, BB4 4EG Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736
www.camfilfarr.co.uk A s p a r
t o f o u r c o n
t i n u o u s
i m p r o v e m e n
t , C a m
f i l F a r r r e s e r v e
t h e r i g h
t t o c h
a n g e s p e c
i f i c a t
i o n s w
i t h o u
t n o t
i c e .
M ega lam U (Ge l) - H1 4 & U1 5
Advantages
Application: Final filtration for clean rooms and housings.Type: HEPA/ULPA filter with gel seal.Frame: Anodized aluminium.Gasket: PU gel.Media: Glass fibre paper.Separator: Hot melt beads.Sealant: Polyurethane.Grid: Mild steel white epoxy paint upstream and downstream.EN 1 8 22 efficiency: H14 and U15.MPPS efficiency: H14 = 99.995%, U15 = 99.9995%.Temperature: 70 C maximum in continuous service.Test: 100%individually scanned in accordance with EN 1822.
W D
Leaktightness by means of gel 100% individual control
Can be assembled withoutclamping
Ref erence TypeFilter
c lass i f ica t ionEN 1822
Dimensions(WxHxD)mm
Mediaarea m
Air f low/pressured r op m / h / Pa
Ai r f l ow /pressure dropmax m/h/ Pa
Uni tvolume m
Uni tweight
kg
3413.08.96 MEGALAM MDA U H14 305x305x78 2.4 150/120 250/200 0.01 2.0
3413.08.89 MEGALAM MDA U H14 305x610x78 4.8 300/120 300/200 0.02 4.0
3413.08.79 MEGALAM MDA U H14 610x610x78 10.0 600/120 1000/200 0.03 6.0
3413.08.87 MEGALAM MDA U H14 915x610x78 14.8 900/120 1500/200 0.05 8.0
3413.08.90 MEGALAM MDA U H14 1220x610x78 19.8 1200/120 2000/200 0.06 11.0
3413.08.97 MEGALAM MDA U H14 305x762x78 6.1 375/120 625/200 0.02 4.5
3413.08.98 MEGALAM MDA U H14 915x762x78 18.6 1125/120 1875/200 0.05 9.03413.08.91 MEGALAM MDA U H14 1220x762x78 24.9 1500/120 2500/200 0.07 13.0
3413.08.88 MEGALAM MDA U H14 915x915x78 22.3 1350/120 2250/200 0.06 12.0
3413.08.95 MEGALAM MDA U H14 1220x915x78 29.0 1800/120 3000/200 0.08 15.0
3413.08.82 MEGALAM MDGS U U15 762x610x78 14.0 750/140 - 0.04 6.5
3413.08.81 MEGALAM MDGS U U15 915x610x78 16.9 900/140 - 0.05 8.0
3413.18.02 MEGALAM MDGS U U15 915x762x78 21.1 1125/140 - 0.05 9.0
3413.08.84 MEGALAM MDGS U U15 1220x762x78 28.3 1500/140 - 0.07 13.0
3413.08.80 MEGALAM MDGS U U15 915x915x78 25.3 1350/140 - 0.06 12.0
Other dimensions available on request .
EN1822N 8
8/10/2019 41-60Pages from Camfil Farr Product Catalog _product_catalogue_2008_en-gb-3.pdf
18/20
H E PA / U L PA F i l t e rs , C l a ss H 1 0 t o U 1 7
56
H E PA / U L PA P a n e l s
A s p a r
t o f o u r c o n
t i n u o u s
i m p r o v e m e n
t , C a m
f i l F a r r r e s e r v e
t h e r i g h
t t o c h
a n g e s p e c
i f i c a t
i o n s w
i t h o u
t n o t
i c e .
Knowsley Road, Haslingden, Lancashire, BB4 4EG Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736
www.camfilfarr.co.uk
M egalam T (Gel) - H1 4 & U1 5
Advantages
Application: Gel seal filter for terminal housings and laminar flow environments.Type: HEPA/ULPA filter with gel seal.Frame: Extruded anodised aluminium.Media: Glass fibre paper.Separator: Hot-melt beads.Sealant: Polyurethane.Gasket: PU Gel.EN 1 8 22 efficiency: H14 and U15.MPPS efficiency: H14 = 99.995%, U15 = 99.9995%.Recommended final pressure drop: 600 Pa.Maximum air flow rate: See table, use nominal values otherwise a reduction in efficiency mayoccur.Temperature: 70 C maximum in continuous service.Test: 100%individually scanned in accordance with EN 1822.Mounting systems: Ceiling mounted grid systems and terminal housings.
W D
Compact design Secure protection of the filter
media
1 0 0 % individually scann testedin accordance with EN 1822
Laminar air flow distribution
Ref erence Type ModelDimensions
(WxHxD)mm
Fi l t e r c l a s s i f i ca t ionEN 1822
Mediaaream2
Air f low/pressured ro p m3 / h / Pa
Uni t we igh tkg U n i t vo l u m e m
3
3471.x0.10 MEGALAM MDT14 U-305x305x71-2G 305x305x71 H14 2,4 150/120 1 0,01
3471.x0.20 MEGALAM MDT14 U-305x610x71-2G 305x610x71 H14 4,8 300/120 2 0,02
3471.x0.30 MEGALAM MDT14 U-610x610x71-2G 610x610x71 H14 10 600/120 4 0,03
3471.x0.90 MEGALAM MDT14 U-762x610x71-2G 762X610X71 H14 12,3 750/120 5 0,04
3471.x0.40 MEGALAM MDT14 U-915x610x71-2G 915x610x71 H14 14,8 900/120 6 0,05
3471.x0.50 MEGALAM MDT14 U-1220x610x71-2G 1220x610x71 H14 19,8 1200/120 8 0,06
3471.x0.80 MEGALAM MDT14 U-305x762x71-2G 305x762x71 H14 6 375/120 2,5 0,02
3471.x1.00 MEGALAM MDT14 U-915x762x71-2G 915x762x71 H14 18,6 1125/120 7,5 0,06
3471.x1.10 MEGALAM MDT14 U-1220x762x71-2G 1220x762x71 H14 24,9 1500/120 10 0,07
3471.x1.50 MEGALAM MDT14 U-915x915x71-2G 915x915x71 H14 22,3 1350/120 9 0,06
3471.x1.60 MEGALAM MDT14 U-1220x915x71-2G 1220x915x71 H14 30 1800/120 12 0,08
3472.x0.20 MEGALAM MDT15 U-305x610x71-2G 305x610x71 U15 5,5 300/140 2 0,017
3472.x0.30 MEGALAM MDT15 U-610x610x71-2G 610x610x71 U15 11,2 600/140 4 0,034
3472.x0.90 MEGALAM MDT15 U-762x610x71-2G 762X610X71 U15 14 750/140 5 0,042
3472.x0.40 MEGALAM MDT15 U-915x610x71-2G 915x610x71 U15 16,9 900/140 6 0,051
3472.x0.50 MEGALAM MDT15 U-1220x610x71-2G 1220x610x71 U15 22,5 1200/140 8 0,0683472.x0.80 MEGALAM MDT15 U-305x762x71-2G 305x762x71 U15 7 375/140 2,5 0,021
3472.x1.00 MEGALAM MDT15 U-915x762x71-2G 915x762x71 U15 21,1 1125/140 7,5 0,064
3472.x1.10 MEGALAM MDT15 U-1220x762x71-2G 1220x762x71 U15 28,3 1500/140 10 0,069
3472.x1.50 MEGALAM MDT15 U-915x915x71-2G 915x915x71 U15 25,3 1200/140 9 0,062
Please Note:
Seal Position "01" : x = 2Seal Position "10" : x = 3
Other dimensions available on request
EN1822N 8
8/10/2019 41-60Pages from Camfil Farr Product Catalog _product_catalogue_2008_en-gb-3.pdf
19/2057
P r e -
F i l t r a t
i o n
, C l a s s
G 3
t o
F 5
B a g a n
d
C o m p a c t
F i l t e r s
,
C l a s s
F 5
t o
F 9
H E P A
/ U L P A
F i l t e r s
, C l a s s
H 1
0
t o
U 1 7
C a r
b o n
a n
d
C h e m
i c a
l F i l t e r s
F i l t e r
F r a m e s a n
d
H o u s
i n g s
A i r F i l t e r
T e c
h n o
l o g y
C a m
f i l F a r r
S o
l u t
i o n sH E PA / U L PA F i l t e r s, C l a ss H 1 0 t o U 1 7
H E PA / U L PA P a n e l s
Knowsley Road, Haslingden, Lancashire, BB4 4EG Tel: +44 (0) 1706 238000, Fax: +44 (0) 1706 226736
www.camfilfarr.co.uk A s p a r
t o f o u r c o n
t i n u o u s
i m p r o v e m e n
t , C a m
f i l F a r r r e s e r v e
t h e r i g h
t t o c h
a n g e s p e c
i f i c a t
i o n s w
i t h o u
t n o t
i c e .
M egalam M D & M X e-PTFE - U1 5
Advantages
Application: Very high efficiency final filter for clean environments and LAF benches.Type: ULPA filter.Frame: Extruded anodised aluminium.Media: e PTFE (Teflon).Separator : Hot-melt beads.Sealant: Polyurethane.Gasket : Half round continuous expanded polyurethane.EN 1 8 22 efficiency: U15MPPS efficiency: > 99.9995%Maximum air flow rate: See table, use nominal values otherwise a reduction in efficiency mayoccur.Temperature: 70 C maximum in continuous service.Test: 100%individually scanned in accordance with EN 1822.Mounting system: Ceiling mounted grid systems, terminal housings and clean devices.
W D
Very high efficiency High mechanical strength
Chemical resistance No outgassing
Ref erence Type Fi l ter c lass i f ica t ionEN 1822Dimensions(WxHxD)mm
Mediaarea m
Air f low/Preassured r op m / h/ Pa
Uni tvolume m
Uni tweight kg
1645020Z MD15/PTFE-305610 U15 305x610x66 4,80 300/105 0,017 2,00
1645050B MD15/PTFE-610610 U15 610x610x66 9,70 605/100 0,034 4,00
1645150 MD15/PTFE-1220610 U15 1220x610x66 19,50 1205/100 0,068 8,00
164550P1 MD15/PTFE-1220915 U15 1220x915x66 29,20 1810/100 0,083 12,00
164902 MX15/PTFE-305610 U15 305x610x90 6,60 300/85 0,023 2,80164907 MX15/PTFE-610610 U15 610x610x90 13,20 605/80 0,046 5,60
1649000 MX15/PTFE-1220610 U15 1220x610x90 26,60 1205/80 0,092 11,20
16490000 MX15/PTFE-1220915 U15 1220x915x90 40,10 1810/80 0,112 16,80
EN1822N 8
8/10/2019 41-60Pages from Camfil Farr Product Catalog _product_catalogue_2008_en-gb-3.pdf
20/20
H E PA / U L PA F i l t e rs , C l a ss H 1 0 t o U 1 7
N o t e s
a r t o f o u r c o n
t i n u o u s
i m p r o v e m e n
t , C a m
f i l F a r r r e s e r v e
t h e r i g h
t t o c h
a n g e s p e c
i f i c a t
i o n s w
i t h o u
t n o t
i c e .
Knowsley Road, Haslingden, Lancashire, BB4 4EGTel: +44 (0) 1706 238000 Fax: +44 (0) 1706 226736
Recommended