Sales ProgramGendriveDiesel Engines Edition 1/15
valid from 01/2015
8/17/2019 3190171 MTU Gendrive SalesProgram
2/55
2 I Gendrive I Sales Program 2015 Sales Program 2015 I Gendrive I 3
04 A customer-oriented technological leader
06 MTU Gendrive rating definition
12 General specifications
13 Engine designation
14 New products
Gendrive engines - 50 Hz22 3D - Diesel engines for standby power
28 3E - Diesel engines for standby power with overload
30 3F - Diesel engines for data center continuous power
32 3H - Diesel engines for mission critical power
34 3C - Diesel engines for NPP standby power
36 3B - Diesel engines for prime power
42 3G - Diesel engines for grid stability power
44 3C - Diesel engines for prime power limited
46 3A - Diesel engines for continuous power
Gendrive engines - 60 Hz
48 3D - Diesel engines for standby power
52 3F - Diesel engines for data center continuous power54 3H - Diesel engines for mission critical power
56 3C - Diesel engines for NPP standby power
58 3B - Diesel engines for prime power
62 3G - Diesel engines for grid stability power
64 3A - Diesel engines for continuous power
Gendrive engines (switchable) - 50 / 60 Hz
66 3D - Diesel engines for standby power (switchable)
68 3B - Diesel engines for prime power (switchable)
70 3A - Diesel engines for continuous power (switchable)
72 Technical engine data
Cylinder data; dimensions and masses
82 Explanation emission optimization (TA-Luft)
Exhaust emissions
83 Stationary Power Plants
94 Nonroad Mobile Machinery
102 MTU ValueCare
104 Service network
107 Conversion table
Contents G e n e r a l
8/17/2019 3190171 MTU Gendrive SalesProgram
3/55
4 I Gendrive I Sales Program 2015 Sales Program 2015 I Gendrive I 5
A customer-orientedtechnology leader.
MTU is the core brand of Rolls-Royce Power Systems AG, which is
a world-leading provider of high- and medium-speed diesel and
gas engines, complete drive systems, distributed energy systems
and fuel injection systems for the most demanding requirements.
The product range of MTU is one of the widest and most modern
in the sector. We offer comprehensive, powerful and reliable
engine solutions for yachts, commercial ships and naval vessels,construction and industrial vehicles, agricultural machinery,
mining, rail and military vehicles as well as for the oil and gas
industry. We also provide a full line of service products to help
you maximize uptime and performance.
For over 100 years, MTU has been known for cutting-edge
innovation and technological leadership. That same spirit of
innovation inspires our sustainability efforts. Today and in the
future, our focus is on developing and implementing system
solutions to maximize efficiency and meet emissions standards.
MTU supplies its customers with technologically-
advanced products that are proven in the field.
MTU’s range of products and services for
off-highway applications is extensive and includes
both standard and customized solutions.
G e n e r a l
8/17/2019 3190171 MTU Gendrive SalesProgram
4/55
8/17/2019 3190171 MTU Gendrive SalesProgram
5/55
8 I Gendrive I Sales Program 2015 Sales Program 2015 I Gendrive I 9
MTU Gendriverating definition
NPP Standy Power (3C)
NPP Standby Power ratings apply
to installations in thermal power
stations. At constant or varying
load, the number of generator
set operating hours is unlimited.
Quoted ratings are in accordance
with ISO 3046 and are capable
of 10% overload. Products are
qualified in accordance with IEEE
and/or KTA requirements.
Typical applications:
nuclear thermal power plants or
nuclear research facilities
Prime Power (3B)
Prime Power ratings apply to
installations where utility power
is unavailable or unreliable. At
varying load, the number of
generator set operating hours is
unlimited. Quoted ratings are in
accordance with ISO 3046 and
are capable of 10% overload.
Typical applications:
construction sites, remote areas
Grid Stability Power (3G)
Grid Stability Power ratings
apply to installations operating
in support of utility networks
or grids (especially when renew-
able power sources are used).
At constant or varying load,
the number of generator set
operating hours is limited to
1000 hours per year. Full
power output is available for 500
hours non-stop operation per
year. Quoted ratings are in
accordance with ISO 3046 andare capable of 10% overload.
Typical applications:
peak shaving, grid stability and
capacity programs
Prime Power Limited (3C)
Prime Power limited ratings apply
to installations where utility
power is unavailable or unreliable.
At varying load, the number of
generator set operating hours is
limited to 1000 hours per year.
Quoted ratings are in accordance
with ISO 3046 and are capable
of 10% overload.
Main usage:
peak shaving, grid stability
G e n e r a l
8/17/2019 3190171 MTU Gendrive SalesProgram
6/55
10 I Gendrive I Sales Program 2015 Sales Program 2015 I Gendrive I 11
MTU Gendriverating definition G e
n e r a l
Continous Power (3A)
Continuous Power ratings apply
to installations where one or
several generator sets serve as
utility. At constant or varying
load, the number of generator
set operating hours is unlimited.
Quoted ratings are in accor-
dance with ISO 3046 and are
capable of 10% overload.
Typical applications:
power stations
Overview of values
Standby Power Standby Power Data Center Mission Critical NPP Standby
(3D) with Overload (3E) Continuous Power (3F) Power (3H) Power (3C)
Load variable variable constant & variable variable variable
Load factor ≤ 85 % ≤ 85 % ≤ 100 % ≤ 85 % acc. to KTA&IEEE regul.
10 % overload (ICXN) no yes yes 50 HZ: yes / 60 Hz: no yes
Max. operating hours
(per year) 500 h 1) 500 h 1) unlimited 2) 1000 h 1) unlimited 3)
Rating definition DIN ISO 3046 - IFN DIN ISO 3046 - ICXN DIN ISO 3046 – ICXN 50 Hz: ISO 3046 - ICXN DIN ISO 3046 – ICXN
60 Hz: ISO 3046 - IFN
Prime Power Grid Stability Prime Power Continuous
(3B) Power (3G) Limited (3C) Power (3A)
Load variable constant & variable variable constant & variable
Load factor ≤ 75 % ≤ 100 % ≤ 75 % ≤ 100 %
10 % overload (ICXN) yes yes yes yes
Max. operating hours
(per year) unlimited 1000 h 4) 1000 h unlimited
Rating definition DIN ISO 3046 - ICXN DIN ISO 3046 – ICXN DIN ISO 3046 - ICXN DIN ISO 3046 – ICXN
1) or for the duration of an emergency
2) in data center application where a reliable utility is present
3) where a reliable utility is present
4) 500h with 100% load without interruption
8/17/2019 3190171 MTU Gendrive SalesProgram
7/55
12 I Gendrive I Sales Program 2015 Sales Program 2015 I Gendrive I 13
Diesel engines for power generation with constant speed
> Four-stroke, direct-injection
> Water- and air cooled
> V or In-line configuration
Power Definition
Rated power of diesel engines in this Sales Program
corresponds to ISO 3046
ICFN = ISO standard (continuous) fuel stop power
ICXN = ISO standard (continuous) power exceedable by 10 %
IFN = ISO standard fuel stop power
(ratings also apply to SAE J1995 and J1349 standard conditions)
Standard conditions for diesel engines:
Barometric pressure: 1000 mbar;
Site altitude above sea level: 100 m
Ambient air temperature: 25°C
Charge-air coolant temp.:
Series 956 50°C
Series 2000 55°C for fuel consumption or for
TA-Luft optimized,
45°C for for emission optimized
Series 4000 55°C for fuel consumption or
TA-Luft optimizied,
45°C for emission optimized
Series 4000 Ex3 45°C
Unless otherwice stated rated power available up to:
Site altitude above sea level: 400 m
Ambient air temperature: 40°C
Power ratings for cogeneration plants and special applications
on request.
Please note, specifications are subject to change without further notice.
All dimensions are approximate, more detailed information is included
within installation drawings.
General
specifications
Explanation ofthe engine designation
Series 956
Example:
20 V 956 TB 34Design index
Application segment
Turbocharged/Charge-air cooling
Series
Cylinder-configuration: V = V-engine
No. of cylinders
Series 1600 / 2000 / 4000
Example:
12 V 4000 G 63 LAdditional engine features
Design index
Application segment
Application
Series
Cylinder-configuration: V = V-engine
R = Inline
No. of cylinders
Series 1600/2000/4000/956
Cooling variants
Water-to-air charge air cooling (W2A) 2000/4000/956
Air-to-air charge air cooling (A2A) 1600/2000
For more information about MTU gendrive diesel engines please visit:
www.mtu-online.com
G e n e r a l
8/17/2019 3190171 MTU Gendrive SalesProgram
8/55
14 I Gendrive I Sales Program 2015 Sales Program 2015 I Gendrive I 15
New products
Series 4000 Gx3 – 50 Hz & 60 Hz –
water-to-air charge air cooled (W2A)
Page 28 / 29: Standby Power with Overload (3E)
Page 30 / 31: Data Center Continuous Power (3F)
Page 32 / 33: Mission Critical Power (3H)
Page 34 / 35: NPP Standby Power (3C)Page 42 / 43: Grid Stability Power (3G)
The product portfolio of series 4000 Gx3 has been extended by the
following application groups:
Series 2000 Gx6 – 50 Hz –
air-to-air charge air cooled (A2A)
Page 24 / 25: Standby Power (3D)
Page 38 / 39: Prime Power (3B)
The new Series 2000 Gx6 air-to-air charge air cooled gendrive
engine with common rail injection system is certified to variousemission levels. It serves the power range 665 to 1102 kWm Prime
Power and up to 1235 kWm in Standby Power.
Series 2000 Gx6 - 50 Hz
Frequency: 50 Hz
Cylinder version: 12V / 16V / 18V
Power range: 665 - 1235 kWm
Application groups: Prime Power (3B)
Standby Power (3D)
Emissions: Fuel consumption optimized,
Exhaust emission optimized (TA-Luft)*,
US EPA Nonroad Tier 2 compliant,
NEA Singapore for Off Road Diesel Engines
(ORDE), compliant EPA Tier 2
Series 4000 Gx3 - 50 Hz
Frequency: 50 Hz
Cylinder version: 12V / 16V / 20V
Application groups: Grid Stability Power (3G)
Standby Power with Overload (3E)
Data Center Continuous Power (3F)
Mission Critical Power (3H)
NPP Standby Power (3C)
Series 4000 Gx3 - 60 Hz
Frequency: 60 Hz
Cylinder version: 12V / 16V / 20V
Application groups: Grid Stability Power (3G)
Data Center Continuous Power (3F)
Mission Critical Power (3H)
NPP Standby Power (3C)
* Explanation see page 82Cooling Variants
A2A: air-to-air charge air cooling (TD)
W2A: water-to-air charge air cooling (TB)
N e w P r o u c t s
G e n e r a l
8/17/2019 3190171 MTU Gendrive SalesProgram
9/55
16 I Gendrive I Sales Program 2015 Sales Program 2015 I Gendrive I 17
New products
Seris 2000 Gx6 – 50 Hz –
water-to-air charge air cooled (W2A)
Page 38 / 39: Prime Power (3B)
The new Series 2000 Gx6 water-to-air charge air cooled gendrive
engine with EGR (exhaust gas recirculation) system and common
rail injection system is certified to India CPCB (ARAI) Stage II andTA-Luft emissions. It serves the power range 665 to 709 kWm.
Series 2000 Gx6 - 50 Hz
Frequency: 50 Hz
Cylinder version: 12V
Power range: 665 / 709 kWm
Application groups: Prime Power (3B)
Emissions: India CPCB (ARAI) Stage II,
Exhaust emission optimized (TA-Luft)*
N e w P r o u c t s
G e n e r a l
Series 2000 Gx6 – 60 Hz –
air-to-air charge a ir cooled (A2A)
Page 48 / 49: Standby Power (3D)
The new 18V 2000 Gx6 air-to-air charge air cooled gendrive engine
with common rail injection system is certified to US EPA Nonroad
Tier 2 Stationary.
Series 2000 Gx6 - 60 Hz
Frequency: 60 Hz
Cylinder version: 18V
Power range: 1371 kWm
Application groups: Standby Power (3D)
Emissions: Fuel consumption optimized,
US EPA Nonroad Tier 2 compliant,
US EPA Nonroad Tier 2 Stationary (40 CFR 60)
* Explanation see page 82Cooling Variants
A2A: air-to-air charge air cooling (TD)
W2A: water-to-air charge air cooling (TB)
8/17/2019 3190171 MTU Gendrive SalesProgram
10/55
18 I Gendrive I Sales Program 2015 Sales Program 2015 I Gendrive I 19
Series 2000 Bx6 – 50 Hz / 60 Hz –
switchable – air-to-air charge air cooled (A2A)
Page 68 / 69: Prime Power (3B)
The new Series 2000 Bx6 air-to-air charge air cooled gendrive
engines feature 50 or 60 Hz frequency selection. They are available
as 12V, 16V and 18V models.
Series 2000 Bx6 - 50 Hz / 60 Hz
Frequency: 50 Hz / 60 Hz
Cylinder version: 12V / 16V / 18V
Power range: 709 - 1097 kWm
Application groups: Prime Power (3B)
Emissions: Fuel consumption optimized,
Exhaust emission optimized (TA-Luft)*,
US EPA Nonroad Tier 2 compliant,
NEA Singapore for Off Road Diesel Engines
(ORDE), compliant EPA Tier 2
* Explanation see page 82Cooling Variants
A2A: air-to-air charge air cooling (TD)
W2A: water-to-air charge air cooling (TB)
G e n e r a lNew products
16V 4000 G83L – 60 Hz –
water-to-air charge air cooled (W2A)
Page 50 / 51: Standby Power (3D)
The 16V 4000 G83L water-to-air charge air cooled gendrive engine
is designed to serve the 2500 kWe power node and is certified to
US EPA Nonroad Tier 2 Stationary.
Series 4000 G83L - 60 Hz
Frequency: 60 Hz
Cylinder version: 16V
Power range: 2740 kWm
Application groups: Standby Power (3D)
Emissions: Fuel-consumption optimized,
US EPA Nonroad Tier 2 compliant,
US EPA Nonroad Tier 2 Stationary (40 CFR 60)
8/17/2019 3190171 MTU Gendrive SalesProgram
11/55
20 I Gendrive I Sales Program 2015 Sales Program 2015 I Gendrive I 21
New products
Series 956 TB34
Page 34 / 35: NNP Standby Power (3C)
Mission critical standby, grid stability / peak shaving services with
variable load. The engine family is available with NPP – standby
service specific qualifications such as KTA 3702 or IEEE.
Series 956 TB34 - 50 Hz
Frequency: 50 Hz
Cylinder Version: 12V / 16V / 20V
Power range: 3900 – 6500 kWm
Application groups: NPP Standby Power (3C)
Emissions: Fuel-consumption optimized
G e n e r a l
Cooling Variants
A2A: air-to-air charge air cooling (TD)
W2A: water-to-air charge air cooling (TB)
8/17/2019 3190171 MTU Gendrive SalesProgram
12/55
22 I Gendrive I Sales Program 2015 Sales Program 2015 I Gendrive I 23
kVA kWe kWm bhp
300 240 274 367 x x x x x A2A x 6R 1600 G70F
330 264 301 404 x x x x x A2A x 6R 1600 G80F
400 320 358 480 x x x x x A2A x 8V 1600 G70F
440 352 394 528 x x x x x A2A x 8V 1600 G80F
500 400 448 601 x x x x x A2A x 10V 1600 G70F
550 440 493 661 x x x x A2A x 10V 1600 G80F
650 520 576 772 x x x A2A x 12V 1600 G70F
715 572 634 850 x x x A2A x 12V 1600 G80F
F u e l c o n s u m p t i o n o p t i m i z e d
E x h a u s t e m i s s i o n o p t i m i z e d
( T A - L u f t ) ( 2 )
E U N o n r o a d
S t a g e I I I A
U S E P A N o n r o a d T i e r 2
c o m p l i a n t
N E A S i n g a p o r e f o r O R D E ,
c o m p l i a n t E P A T i e r 2
C o o l i n g v a r i a n t
C o o l i n g p a c k a g e i n c l u d e d
E n g i n e m o d e l
Typical Rating Emissions Standard Cooling Engine
Generator Set
output (1)
50 Hz – 1500 rpm
274 kWm - 634 kWmGendrive enginesStandby Power (3D)
Cooling Variants
A2A: air-to-air charge air cooling (TD)
W2A: water-to-air charge air cooling (TB)
(1) The quoted typical kVA / kWe ratings are based on typical generator
efficiencies.
The kVA figures are calculated with a 0.8 power factor.
Typical deductions for fan drive power and generator efficiency is appliedfor calculation and serves as guideline only.
reference to emission level in price list
(2) Explanation see page 82
24 22 251981
22 25 S t a n d b y P o w e r - 5 0 H z
241981
I n d i a C P C B ( A R A I ) S t a g e I
I n d i a C P C B ( A R A I ) S t a g e I I
8/17/2019 3190171 MTU Gendrive SalesProgram
13/55
24 I Gendrive I Sales Program 2015 Sales Program 2015 I Gendrive I 25
kVA kWe kWm bhp
715 572 635 852 x x A2A x 12V 2000 G25
715 572 635 852 x W2A 12V 2000 G25
825 660 732 982 x x x A2A x 12V 2000 G76F
860 688 765 1026 x x A2A x 12V 2000 G65
860 688 765 1026 x W2A 12V 2000 G65
1000 800 887 1189 x A2A x 12V 2000 G86F
1000 800 890 1194 x A2A x 16V 2000 G25
1000 800 890 1194 x W2A 16V 2000 G25
1100 880 975 1307 x A2A x 16V 2000 G65
1100 880 975 1307 x W2A 16V 2000 G65
1110 888 979 1313 x x x A2A x 16V 2000 G76F
1250 1000 1100 1475 x A2A x 18V 2000 G65 (3)
1250 1000 1100 1475 x A2A x 16V 2000 G86F
1250 1000 1100 1475 x W2A 18V 2000 G65 (3)
1400 1120 1235 1656 x A2A x 18V 2000 G76F
F u e l c o n s u m p t i o n o p t i m i z e d
E x h a u s t e m i s s i o n o p t i m i z e d
( T A - L u f t ) ( 2 )
E U N o n r o a d
S t a g e I I I A
U S E P A N o n r o a d T i e r 2
c o m p l i a n t
N E A S i n g a p o r e f o r O R D E ,
c o m p l i a n t E P A T i e r 2
Typical Rating Emissions Standard Cooling Engine
Generator Set
output (1)
50 Hz – 1500 rpm
635 kWm - 1235 kWmGendrive enginesStandby Power (3D)
Cooling Variants
A2A: air-to-air charge air cooling (TD)
W2A: water-to-air charge air cooling (TB)
(1) The quoted typical kVA / kWe ratings are based on typical generator
efficiencies.
The kVA figures are calculated with a 0.8 power factor.
Typical deductions for fan drive power and generator efficiency is applied
for calculation and serves as guideline only.
(2) Explanation see page 82
(3) Series 18V 2000 G65 without power
reduction available up to 35°C / 400 m
reference to emission level in price list
24 22 251981
C o o l i n g v a r i a n t
C o o l i n g p a c k a g e i n c l u d e d
E n g i n e m o d e l
22 25 S t a n d b y P o w e r - 5 0 H z
241981
I n d i a C P C B ( A R A I ) S t a g e I
I n d i a C P C B ( A R A I ) S t a g e I I
8/17/2019 3190171 MTU Gendrive SalesProgram
14/55
26 I Gendrive I Sales Program 2015 Sales Program 2015 I Gendrive I 27
kVA kWe kWm bhp
1800 1440 1575 2112 x x W2A 12V 4000 G23
2000 1600 1750 2347 x x W2A 12V 4000 G63 (4)
2250 1800 1965 2635 x x W2A 16V 4000 G23
2500 2000 2185 2930 x x W2A 16V 4000 G63
2800 2240 2420 3245 x x W2A 20V 4000 G23
3100 2480 2670 3581 x x W2A 20V 4000 G63 (3)
3300 2640 2850 3822 x x W2A 20V 4000 G63L (4)
F u e l c o n s u m p t i o n o p t i m i z e d
E x h a u s t e m i s s i o n o p t i m i z e d
( T A - L u f t ) ( 2 )
E U N o n r o a d
S t a g e I I I A
U S E P A N o n r o a d T i e r 2
c o m p l i a n t
N E A S i n g a p o r e f o r O R D E ,
c o m p l i a n t E P A T i e r 2
Typical Rating Emissions Standard Cooling Engine
Generator Set
output (1)
50 Hz – 1500 rpm
1575 kWm - 2850 kWmGendrive enginesStandby Power (3D)
Cooling Variants
A2A: air-to-air charge air cooling (TD)
W2A: water-to-air charge air cooling (TB)
(1) The quoted typical kVA / kWe ratings are based on typical generator
efficiencies.
The kVA figures are calculated with a 0.8 power factor.
Typical deductions for fan drive power and generator efficiency is applied
for calculation and serves as guideline only.
(2) Explanation see page 82
(3) Series 20V 4000 G63 without power
reduction available up to 35°C / 400 m
(4) Series 12V 4000 G63 / 20V 4000 G63L
without power reduction available up to
30°C / 400 m
reference to emission level in price list
24 22 251981
C o o l i n g v a r i a n t
C o o l i n g p a c k a g e i n c l u d e d
E n g i n e m o d e l
22 25 S t a n d b y P o w e r - 5 0 H z
241981
I n d i a C P C B ( A R A I ) S t a g e I
I n d i a C P C B ( A R A I ) S t a g e I I
8/17/2019 3190171 MTU Gendrive SalesProgram
15/55
28 I Gendrive I Sales Program 2015 Sales Program 2015 I Gendrive I 29
kVA kWe kWm bhp
1600 1280 1420 1904 x x x W2A 12V 4000 G23
1800 1440 1575 2112 x x x W2A 12V 4000 G63 (4)
2100 1680 1798 2411 x x x W2A 16V 4000 G23
2250 1800 1965 2635 x x x W2A 16V 4000 G63
2500 2000 2200 2950 x x x W2A 20V 4000 G23
2800 2240 2420 3245 x x x W2A 20V 4000 G63 (3)
3000 2400 2590 3473 x x x W2A 20V 4000 G63L (4)
F u e l c o n s u m p t i o n o p t i m i z e d
E x h a u s t e m i s s i o n o p t i m i z e d
( T A - L u f t ) ( 2 )
E U N o n r o a d
S t a g e I I I A
U S E P A N o n r o a d T i e r 2
c o m p l i a n t
N E A S i n g a p o r e f o r O R D E ,
c o m p l i a n t E P A T i e r 2
Typical Rating Emissions Standard Cooling Engine
Generator Set
output (1)
50 Hz – 1500 rpm
1420 kWm - 2590 kWmGendrive enginesStandby Powerwith Overload (3E)
Cooling Variants
A2A: air-to-air charge air cooling (TD)
W2A: water-to-air charge air cooling (TB)
(1) The quoted typical kVA / kWe ratings are based on typical generator
efficiencies.
The kVA figures are calculated with a 0.8 power factor.
Typical deductions for fan drive power and generator efficiency is applied
for calculation and serves as guideline only.
(2) Explanation see page 82
(3) Series 20V 4000 G63 without power
reduction available up to 35°C / 400 m
(4) Series 12V 4000 G63 / 20V 4000 G63L
without power reduction available up to
30°C / 400 m
reference to emission level in price list
24 22 251981
C o o l i n g v a r i a n t
C o o l i n g p a c k a g e i n c l u d e d
E n g i n e m o d e l
22 25
S t a n d b y P o w e r w i t h O v e r l o a d - 5 0 H z
241981
I n d i a C P C B ( A R A I ) S t a g e I
I n d i a C P C B ( A R A I ) S t a g e I I
8/17/2019 3190171 MTU Gendrive SalesProgram
16/55
30 I Gendrive I Sales Program 2015 Sales Program 2015 I Gendrive I 31
kVA kWe kWm bhp
1600 1280 1420 1904 x x x W2A 12V 4000 G23
1800 1440 1575 2112 x x x W2A 12V 4000 G63 (4)
2100 1680 1798 2411 x x x W2A 16V 4000 G23
2250 1800 1965 2635 x x x W2A 16V 4000 G63
2500 2000 2200 2950 x x x W2A 20V 4000 G23
2800 2240 2420 3245 x x x W2A 20V 4000 G63 (3)
3000 2400 2590 3473 x x x W2A 20V 4000 G63L (4)
F u e l c o n s u m p t i o n o p t i m i z e d
E x h a u s t e m i s s i o n o p t i m i z e d
( T A - L u f t ) ( 2 )
E U N o n r o a d
S t a g e I I I A
U S E P A N o n r o a d T i e r 2
c o m p l i a n t
N E A S i n g a p o r e f o r O R D E ,
c o m p l i a n t E P A T i e r 2
Typical Rating Emissions Standard Cooling Engine
Generator Set
output (1)
50 Hz – 1500 rpm
1420 kWm - 2590 kWmGendrive enginesData CenterContinuous Power (3F)
Cooling Variants
A2A: air-to-air charge air cooling (TD)
W2A: water-to-air charge air cooling (TB)
(1) The quoted typical kVA / kWe ratings are based on typical generator
efficiencies.
The kVA figures are calculated with a 0.8 power factor.
Typical deductions for fan drive power and generator efficiency is applied
for calculation and serves as guideline only.
(2) Explanation see page 82
(3) Series 20V 4000 G63 without power
reduction available up to 35°C / 400 m
(4) Series 12V 4000 G63 / 20V 4000 G63L
without power reduction available up to
30°C / 400 m
reference to emission level in price list
24 22 251981
C o o l i n g v a r i a n t
C o o l i n g p a c k a g e i n c l u d e d
E n g i n e m o d e l
22 25
D a t a C e n t e r C o n t i n u o u s P o w e r - 5 0 H
z241981
I n d i a C P C B ( A R A I ) S t a g e I
I n d i a C P C B ( A R A I ) S t a g e I I
8/17/2019 3190171 MTU Gendrive SalesProgram
17/55
32 I Gendrive I Sales Program 2015 Sales Program 2015 I Gendrive I 33
kVA kWe kWm bhp
1600 1280 1420 1904 x x x W2A 12V 4000 G23
1800 1440 1575 2112 x x x W2A 12V 4000 G63 (4)
2100 1680 1798 2411 x x x W2A 16V 4000 G23
2250 1800 1965 2635 x x x W2A 16V 4000 G63
2500 2000 2200 2950 x x x W2A 20V 4000 G23
2800 2240 2420 3245 x x x W2A 20V 4000 G63 (3)
3000 2400 2590 3473 x x x W2A 20V 4000 G63L (4)
F u e l c o n s u m p t i o n o p t i m i z e d
E x h a u s t e m i s s i o n o p t i m i z e d
( T A - L u f t ) ( 2 )
E U N o n r o a d
S t a g e I I I A
U S E P A N o n r o a d T i e r 2
c o m p l i a n t
N E A S i n g a p o r e f o r O R D E ,
c o m p l i a n t E P A T i e r 2
Typical Rating Emissions Standard Cooling Engine
Generator Set
output (1)
50 Hz – 1500 rpm
1420 kWm - 2590 kWmGendrive enginesMission Critical Power (3H)
Cooling Variants
A2A: air-to-air charge air cooling (TD)
W2A: water-to-air charge air cooling (TB)
(1) The quoted typical kVA / kWe ratings are based on typical generator
efficiencies.
The kVA figures are calculated with a 0.8 power factor.
Typical deductions for fan drive power and generator efficiency is applied
for calculation and serves as guideline only.
(2) Explanation see page 82
(3) Series 20V 4000 G63 without power
reduction available up to 35°C / 400 m
(4) Series 12V 4000 G63 / 20V 4000 G63L
without power reduction available up to
30°C / 400 m
reference to emission level in price list
24 22 251981
C o o l i n g v a r i a n t
C o o l i n g p a c k a g e i n c l u d e d
E n g i n e m o d e l
22 25
M i s s i o n C r i t i c a l P o w e r - 5 0 H z
241981
I n d i a C P C B ( A R A I ) S t a g e I
I n d i a C P C B ( A R A I ) S t a g e I I
8/17/2019 3190171 MTU Gendrive SalesProgram
18/55
34 I Gendrive I Sales Program 2015 Sales Program 2015 I Gendrive I 35
kVA kWe kWm bhp
1800 1440 1560 2092 x W2A 12V 4000 E63 (3) (4)
2400 1920 2080 2789 x W2A 16V 4000 E63 (3) (4)
3000 2400 2600 3487 x W2A 20V 4000 E63 (4)
4400 3520 3900 5230 x W2A 12V 956 TB34 (3)
5820 4656 5200 6973 x W2A 16V 956 TB34 (3)
7275 5820 6500 8717 x W2A 20V 956 TB34
F u e l c o n s u m p t i o n o p t i m i z e d
E x h a u s t e m i s s i o n o p t i m i z e d
( T A - L u f t ) ( 2 )
E U N o n r o a d
S t a g e I I I A
U S E P A N o n r o a d T i e r 2
c o m p l i a n t
N E A S i n g a p o r e f o r O R D E ,
c o m p l i a n t E P A T i e r 2
Typical Rating Emissions Standard Cooling Engine
Generator Set
output (1)
50 Hz – 1500 rpm
1560 kWm - 6500 kWm
C o o l i n g v a r i a n t
C o o l i n g p a c k a g e i n c l u d e d
E n g i n e m o d e l
22 25
Gendrive enginesNPP Standby Power (3C)
N P P S
t a n d b y P o w e r - 5 0 H z
241981
I n d i a C P C B ( A R A I ) S t a g e I
I n d i a C P C B ( A R A I ) S t a g e I I
Cooling Variants
A2A: air-to-air charge air cooling (TD)
W2A: water-to-air charge air cooling (TB)
(1) The quoted typical kVA / kWe ratings are based on typical generator
efficiencies.
The kVA figures are calculated with a 0.8 power factor.
Typical deductions for fan drive power and generator efficiency is applied
for calculation and serves as guideline only.
(2) Explanation see page 82
(3) Available on request
(4) S4000 E63 with KTA or IEEE
qualifications
reference to emission level in price list
24 22 251981
8/17/2019 3190171 MTU Gendrive SalesProgram
19/55
36 I Gendrive I Sales Program 2015 Sales Program 2015 I Gendrive I 37
kVA kWe kWm bhp
275 220 249 334 x x x x x x A2A x 6R 1600 G10F
300 240 274 367 x x x x x x A2A x 6R 1600 G20F
365 292 325 436 x x x x x x A2A x 8V 1600 G10F
400 320 358 480 x x x x x x A2A x 8V 1600 G20F
450 360 407 546 x x x x x x A2A x 10V 1600 G10F
500 400 448 601 x x x x x x A2A x 10V 1600 G20F
590 472 524 703 x x x x A2A x 12V 1600 G10F
650 520 576 772 x x x x A2A x 12V 1600 G20F
F u e l c o n s u m p t i o n o p t i m i z e d
E x h a u s t e m i s s i o n o p t i m i z e d
( T A - L u f t ) ( 2 )
E U N o n r o a d
S t a g e I I I A
U S E P A N o n r o a d T i e r 2
c o m p l i a n t
N E A S i n g a p o r e f o r O R D E ,
c o m p l i a n t E P A T i e r 2
C o o l i n g v a r i a n t
C o o l i n g p a c k a g e i n c l u d e d
E n g i n e m o d e l
Typical Rating Emissions Standard Cooling Engine
Generator Set
output (1)
50 Hz – 1500 rpm
249 kWm - 576 kWm
Cooling Variants
A2A: air-to-air charge air cooling (TD)
W2A: water-to-air charge air cooling (TB)
(1) The quoted typical kVA / kWe ratings are based on typical generator
efficiencies.
The kVA figures are calculated with a 0.8 power factor.
Typical deductions for fan drive power and generator efficiency is appliedfor calculation and serves as guideline only.
reference to emission level in price list
(2) Explanation see page 82
24 22 251981
22 25
Gendrive enginesPrime Power (3B)
P r i m e P o w e r - 5 0 H z
241981
I n d i a C P C B ( A R A I ) S t a g e I
I n d i a C P C B ( A R A I ) S t a g e I I
8/17/2019 3190171 MTU Gendrive SalesProgram
20/55
38 I Gendrive I Sales Program 2015 Sales Program 2015 I Gendrive I 39
kVA kWe kWm bhp
650 520 580 778 x x x A2A x 12V 2000 G25
650 520 580 778 x W2A 12V 2000 G25
750 600 665 892 x x x x A2A x 12V 2000 G16F
750 600 665 892 x x W2A 12V 2000 G56F
780 624 695 932 x x x A2A x 12V 2000 G65
780 624 695 932 x W2A 12V 2000 G65
800 640 709 951 x x x x A2A x 12V 2000 G26F
800 640 709 951 x x W2A 12V 2000 G66F
910 728 806 1081 x x x x A2A x 16V 2000 G16F
910 728 810 1086 x x A2A x 16V 2000 G25
910 728 810 1086 x W2A 16V 2000 G25
1000 800 890 1194 x x A2A x 16V 2000 G65
1000 800 890 1194 x x x x A2A x 16V 2000 G26F
1000 800 890 1194 x W2A 16V 2000 G65
1135 908 1000 1341 x x A2A x 18V 2000 G65
(3)
1135 908 1000 1341 x x x x A2A x 16V 2000 G36F
1135 908 1000 1341 x W2A 18V 2000 G65 (3)
1250 1000 1102 1478 x x x x A2A x 18V 2000 G26F
F u e l c o n s u m p t i o n o p t i m i z e d
E x h a u s t e m i s s i o n o p t i m i z e d
( T A - L u f t ) ( 2 )
E U N o n r o a d
S t a g e I I I A
U S E P A N o n r o a d T i e r 2
c o m p l i a n t
N E A S i n g a p o r e f o r O R D E ,
c o m p l i a n t E P A T i e r 2
C o o l i n g v a r i a n t
C o o l i n g p a c k a g e i n c l u d e d
E n g i n e m o d e l
Typical Rating Emissions Standard Cooling Engine
Generator Set
output (1)
Gendrive enginesPrime Power (3B)
50 Hz – 1500 rpm
580 kWm - 1102 kWm
Cooling Variants
A2A: air-to-air charge air cooling (TD)
W2A: water-to-air charge air cooling (TB)
(1) The quoted typical kVA / kWe ratings are based on typical generator
efficiencies.
The kVA figures are calculated with a 0.8 power factor.
Typical deductions for fan drive power and generator efficiency is applied
for calculation and serves as guideline only.
(2) Explanation see page 82
(3) Series 18V 2000 G65 for fuel
consumption optimized / without
power reduction available up to
35°C / 400 m
reference to emission level in price list
24 22 251981
22 25
P r i m e P o w e r - 5 0 H z
241981
I n d i a C P C B ( A R A I ) S t a g e I
I n d i a C P C B ( A R A I ) S t a g e I I
8/17/2019 3190171 MTU Gendrive SalesProgram
21/55
40 I Gendrive I Sales Program 2015 Sales Program 2015 I Gendrive I 41
kVA kWe kWm bhp
1365 1092 1205 1616 x x x W2A 12V 4000 G23R
1600 1280 1420 1904 x x x W2A 12V 4000 G23
1800 1440 1575 2112 x x x W2A 12V 4000 G63 (4)
2100 1680 1798 2411 x x x W2A 16V 4000 G23
2250 1800 1965 2635 x x x W2A 16V 4000 G63
2500 2000 2200 2950 x x x W2A 20V 4000 G23
2800 2240 2420 3245 x x x W2A 20V 4000 G63 (3)
3000 2400 2590 3473 x x x W2A 20V 4000 G63L (4)
F u e l c o n s u m p t i o n o p t i m i z e d
E x h a u s t e m i s s i o n o p t i m i z e d
( T A - L u f t ) ( 2 )
E U N o n r o a d
S t a g e I I I A
U S E P A N o n r o a d T i e r 2
c o m p l i a n t
N E A S i n g a p o r e f o r O R D E ,
c o m p l i a n t E P A T i e r 2
C o o l i n g v a r i a n t
C o o l i n g p a c k a g e i n c l u d e d
E n g i n e m o d e l
Typical Rating Emissions Standard Cooling Engine
Generator Set
output (1)
Gendrive enginesPrime Power (3B)
50 Hz – 1500 rpm
1205 kWm - 2590 kWm
Cooling Variants
A2A: air-to-air charge air cooling (TD)
W2A: water-to-air charge air cooling (TB)
(1) The quoted typical kVA / kWe ratings are based on typical generator
efficiencies.
The kVA figures are calculated with a 0.8 power factor.
Typical deductions for fan drive power and generator efficiency is appliedfor calculation and serves as guideline only.
(2) Explanation see page 82
(3) Series 20V 4000 G63 without power
reduction available up to 35°C / 400 m
(4) Series 12V 4000 G63 / 20V 4000 G63Lwithout power reduction available up to
30°C / 400 m
reference to emission level in price list
24 22 251981
22 25
P r i m e P o w e r - 5 0 H z
241981
I n d i a C P C B ( A R A I ) S t a g e I
I n d i a C P C B ( A R A I ) S t a g e I I
8/17/2019 3190171 MTU Gendrive SalesProgram
22/55
42 I Gendrive I Sales Program 2015 Sales Program 2015 I Gendrive I 43
kVA kWe kWm bhp
1600 1280 1420 1904 x x x W2A 12V 4000 G23
1800 1440 1575 2112 x x x W2A 12V 4000 G63 (4)
2100 1680 1798 2411 x x x W2A 16V 4000 G23
2250 1800 1965 2635 x x x W2A 16V 4000 G63
2500 2000 2200 2950 x x x W2A 20V 4000 G23
2800 2240 2420 3245 x x x W2A 20V 4000 G63 (3)
3000 2400 2590 3473 x x x W2A 20V 4000 G63L (4)
F u e l c o n s u m p t i o n o p t i m i z e d
E x h a u s t e m i s s i o n o p t i m i z e d
( T A - L u f t ) ( 2 )
E U N o n r o a d
S t a g e I I I A
U S E P A N o n r o a d T i e r 2
c o m p l i a n t
N E A S i n g a p o r e f o r O R D E ,
c o m p l i a n t E P A T i e r 2
Typical Rating Emissions Standard Cooling Engine
Generator Set
output (1)
50 Hz – 1500 rpm
1420 kWm - 2590 kWmGendrive enginesGrid Stability Power (3G)
Cooling Variants
A2A: air-to-air charge air cooling (TD)
W2A: water-to-air charge air cooling (TB)
(1) The quoted typical kVA / kWe ratings are based on typical generator
efficiencies.
The kVA figures are calculated with a 0.8 power factor.
Typical deductions for fan drive power and generator efficiency is applied
for calculation and serves as guideline only.
(2) Explanation see page 82
(3) Series 20V 4000 G63 without power
reduction available up to 35°C / 400 m
(4) Series 12V 4000 G63 / 20V 4000 G63L
without power reduction available up to
30°C / 400 m
reference to emission level in price list
24 22 251981
C o o l i n g v a r i a n t
C o o l i n g p a c k a g e i n c l u d e d
E n g i n e m o d e l
22 25
G r i d S t a b i l i t y P o w e r - 5 0 H z
241981
I n d i a C P C B ( A R A I ) S t a g e I
I n d i a C P C B ( A R A I ) S t a g e I I
8/17/2019 3190171 MTU Gendrive SalesProgram
23/55
44 I Gendrive I Sales Program 2015 Sales Program 2015 I Gendrive I 45
kVA kWe kWm bhp
275 220 249 334 x x x A2A x 6R 1600 G40F
300 240 274 367 x x x A2A x 6R 1600 G50F
365 292 325 436 x x x A2A x 8V 1600 G40F
400 320 358 480 x x x A2A x 8V 1600 G50F
450 360 407 546 x x x A2A x 10V 1600 G40F
500 400 448 601 x x x A2A x 10V 1600 G50F
590 472 524 703 x x A2A x 12V 1600 G40F
650 520 576 772 x x A2A x 12V 1600 G50F
F u e l c o n s u m p t i o n o p t i m i z e d
E x h a u s t e m i s s i o n o p t i m i z e d
( T A - L u f t ) ( 2 )
E U N o n r o a d
S t a g e I I I A
U S E P A N o n r o a d T i e r 2
c o m p l i a n t
N E A S i n g a p o r e f o r O R D E ,
c o m p l i a n t E P A T i e r 2
C o o l i n g v a r i a n t
C o o l i n g p a c k a g e i n c l u d e d
E n g i n e m o d e l
Typical Rating Emissions Standard Cooling Engine
Generator Set
output (1)
Gendrive enginesPrime Power Limited (3C)
50 Hz – 1500 rpm
249 kWm - 576 kWm
Cooling Variants
A2A: air-to-air charge air cooling (TD)
W2A: water-to-air charge air cooling (TB)
(1) The quoted typical kVA / kWe ratings are based on typical generator
efficiencies.
The kVA figures are calculated with a 0.8 power factor.
Typical deductions for fan drive power and generator efficiency is appliedfor calculation and serves as guideline only.
reference to emission level in price list
(2) Explanation see page 82
24 22 251981
22 25
P r i m e P o w e r L i m i t e d - 5 0 H z
241981
I n d i a C P C B ( A R A I ) S t a g e I
I n d i a C P C B ( A R A I ) S t a g e I I
8/17/2019 3190171 MTU Gendrive SalesProgram
24/55
46 I Gendrive I Sales Program 2015 Sales Program 2015 I Gendrive I 47
kVA kWe kWm bhp
575 460 515 691 x A2A x 12V 2000 G65
575 460 515 691 x W2A 12V 2000 G65
740 592 655 878 x A2A x 16V 2000 G65
740 592 655 878 x W2A 16V 2000 G65
750 600 665 892 x A2A x 12V 2000 B26F
800 640 709 951 x A2A x 16V 2000 B26F
810 648 720 966 x A2A x 18V 2000 G65 (3)
810 648 720 966 x W2A 18V 2000 G65 (3)
1000 800 887 1189 x A2A x 18V 2000 B26F
1480 1184 1310 1757 x W2A 12V 4000 G63 (4)
1875 1500 1635 2193 x W2A 16V 4000 G63
2275 1820 2000 2682 x W2A 20V 4000 G63 (3)
2500 2000 2200 2950 x W2A 20V 4000 G63L (4)
F u e l c o n s u m p t i o n o p t i m i z e d
E x h a u s t e m i s s i o n o p t i m i z e d
( T A - L u f t ) ( 2 )
E U N o n r o a d
S t a g e I I I A
U S E P A N o n r o a d T i e r 2
c o m p l i a n t
N E A S i n g a p o r e f o r O R D E ,
c o m p l i a n t E P A T i e r 2
Typical Rating Emissions Standard Cooling Engine
Generator Set
output (1)
50 Hz – 1500 rpm
515 kWm - 2200 kWm
C o o l i n g v a r i a n t
C o o l i n g p a c k a g e i n c l u d e d
E n g i n e m o d e l
22 25
Gendrive enginesContinuous Power (3A)
C o n t i n u o u s P o w e r - 5 0 H z
241981
I n d i a C P C B ( A R A I ) S t a g e I
I n d i a C P C B ( A R A I ) S t a g e I I
Cooling Variants
A2A: air-to-air charge air cooling (TD)W2A: water-to-air charge air cooling (TB)
(1) The quoted typical kVA / kWe ratings are based on typical generator
efficiencies.
The kVA figures are calculated with a 0.8 power factor.
Typical deductions for fan drive power and generator efficiency is applied
for calculation and serves as guideline only.
(2) Explanation see page 82
(3) Series 18V 2000 G65 / 20V 4000 G63
without power reduction available up to
35°C / 400 m
(4) Series 12V 4000 G63 / 20V 4000 G63L
without power reduction available up to
30°C / 400 m
reference to emission level in price list
24 22 251981
8/17/2019 3190171 MTU Gendrive SalesProgram
25/55
48 I Gendrive I Sales Program 2015 Sales Program 2015 I Gendrive I 49
60 Hz – 1800 rpm
312 kWm - 1371 kWmGendrive enginesStandby Power (3D)
kWe kVA kWm bhp
275 344 312 418 x x A2A x 6R 1600 G70S
300 375 343 460 x x A2A x 6R 1600 G80S
365 456 408 547 x x A2A x 8V 1600 G70S
400 500 448 601 x x A2A x 8V 1600 G80S
450 563 511 685 x x A2A x 10V 1600 G70S
500 625 561 752 x x A2A x 10V 1600 G80S
550 688 613 822 x x A2A x 12V 1600 G70S
600 750 668 896 x x A2A x 12V 1600 G80S
710 888 780 1046 x x A2A x 12V 2000 G45
710 888 780 1046 x x W2A 12V 2000 G45
800 1000 890 1194 x x A2A x 12V 2000 G85
800 1000 890 1194 x x W2A 12V 2000 G85
925 1156 1010 1354 x x A2A x 16V 2000 G45
925 1156 1010 1354 x x W2A 16V 2000 G45
1000 1250 1115 1495 x x A2A x 16V 2000 G851000 1250 1115 1495 x x W2A 16V 2000 G85
1200 1500 1310 1757 x x A2A x 18V 2000 G85
1200 1500 1310 1757 x x W2A 18V 2000 G85
1250 1563 1371 1839 x x x A2A x 18V 2000 G76S
F u e l c o n s u m p t i o n o p t i m i z e d
U S E P A N o n r o a d T i e r 2
c o m p l i a n t
U S E P A N o n r o a d T i e r 2
S t a t i o n a r y ( 4 0 C F R 6 0 )
U S E P A N o n r o a d T i e r 3
c o m p l i a n t
U S E P A N o n r o a d T i e r 3
S t a t i o n a r y ( 4 0 C F R 6 0 )
C o o l i n g v a r i a n t
C o o l i n g p a c k a g e i n c l u d e d
E n g i n e m o d e l
Typical Rating Emissions Standard Cooling Engine
Generator Set
output (1)
Cooling Variants
A2A: air-to-air charge air cooling (TD)
W2A: water-to-air charge air cooling (TB)
(1) The quoted typical kVA / kWe ratings are based on typical generator
efficiencies.
The kVA figures are calculated with a 0.8 power factor.
Typical deductions for fan drive power and generator efficiency is applied
for calculation and serves as guideline only.
20 719 3
reference to emission level in price list
S t a n d b y P o w e r - 6 0 H z
20 719 3
8/17/2019 3190171 MTU Gendrive SalesProgram
26/55
50 I Gendrive I Sales Program 2015 Sales Program 2015 I Gendrive I 51
60 Hz – 1800 rpm
1736 kWm - 3490 kWmGendrive enginesStandby Power (3D)
kWe kVA kWm bhp
1600 2000 1736 2328 x x x W2A 12V 4000 G43
1750 2188 1910 2561 x x x W2A 12V 4000 G83
2100 2625 2280 3058 x x x W2A 16V 4000 G43
2300 2875 2500 3353 x x x W2A 16V 4000 G83
2550 3188 2740 3674 x x x W2A 16V 4000 G83L
2550 3188 2740 3674 x x x W2A 20V 4000 G43
2800 3500 3010 4036 x x x W2A 20V 4000 G83
3250 4063 3490 4680 x x x W2A 20V 4000 G83L
F u e l c o n s u m p t i o n o p t i m i z e d
U S E P A N o n r o a d T i e r 2
c o m p l i a n t
U S E P A N o n r o a d T i e r 2
S t a t i o n a r y ( 4 0 C F R 6 0 )
U S E P A N o n r o a d T i e r 3
c o m p l i a n t
U S E P A N o n r o a d T i e r 3
S t a t i o n a r y ( 4 0 C F R 6 0 )
Typical Rating Emissions Standard Cooling Engine
Generator Set
output (1)
C o o l i n g v a r i a n t
C o o l i n g p a c k a g e i n c l u d e d
E n g i n e m o d e l
20 719 3Cooling Variants
A2A: air-to-air charge air cooling (TD)
W2A: water-to-air charge air cooling (TB)
(1) The quoted typical kVA / kWe ratings are based on typical generator
efficiencies.
The kVA figures are calculated with a 0.8 power factor.
Typical deductions for fan drive power and generator efficiency is appliedfor calculation and serves as guideline only.
reference to emission level in price list
S t a n d b y P o w e r - 6 0 H z
20 719 3
8/17/2019 3190171 MTU Gendrive SalesProgram
27/55
52 I Gendrive I Sales Program 2015 Sales Program 2015 I Gendrive I 53
kWe kVA kWm bhp
1400 1750 1520 2038 x x x W2A 12V 4000 G43
1600 2000 1736 2328 x x x W2A 12V 4000 G83
1850 2313 2020 2709 x x x W2A 16V 4000 G43
2100 2625 2280 3058 x x x W2A 16V 4000 G83
2300 2875 2490 3339 x x x W2A 20V 4000 G43
2550 3188 2740 3674 x x x W2A 20V 4000 G83
2800 3500 3010 4036 x x x W2A 20V 4000 G83L
F u e l c o n s u m p t i o n o p t i m i z e d
U S E P A N o n r o a d T i e r 2
c o m p l i a n t
U S E P A N o n r o a d T i e r 2
S t a t i o n a r y ( 4 0 C F R 6 0 )
U S E P A N o n r o a d T i e r 3
c o m p l i a n t
U S E P A N o n r o a d T i e r 3
S t a t i o n a r y ( 4 0 C F R 6 0 )
C o o l i n g v a r i a n t
C o o l i n g p a c k a g e i n c l u d e d
E n g i n e m o d e l
Typical Rating Emissions Standard Cooling Engine
Generator Set
output (1)
60 Hz – 1800 rpm
1520 kWm - 3010 kWmGendrive enginesData CenterContinuous Power (3F)
20 719 3Cooling Variants
A2A: air-to-air charge air cooling (TD)
W2A: water-to-air charge air cooling (TB)
(1) The quoted typical kVA / kWe ratings are based on typical generator
efficiencies.
The kVA figures are calculated with a 0.8 power factor.
Typical deductions for fan drive power and generator efficiency is applied
for calculation and serves as guideline only.
reference to emission level in price list
D a t a C e n t e r C o n t i n u o u s P o w e r - 6 0 H
z20 719 3
8/17/2019 3190171 MTU Gendrive SalesProgram
28/55
54 I Gendrive I Sales Program 2015 Sales Program 2015 I Gendrive I 55
kWe kVA kWm bhp
1600 2000 1736 2328 x x x W2A 12V 4000 G43
1750 2188 1910 2561 x x x W2A 12V 4000 G83
2100 2625 2280 3058 x x x W2A 16V 4000 G43
2300 2875 2500 3353 x x x W2A 16V 4000 G83
2550 3188 2740 3674 x x x W2A 16V 4000 G83L
2550 3188 2740 3674 x x x W2A 20V 4000 G43
2800 3500 3010 4036 x x x W2A 20V 4000 G83
3250 4063 3490 4680 x x x W2A 20V 4000 G83L
F u e l c o n s u m p t i o n o p t i m i z e d
U S E P A N o n r o a d T i e r 2
c o m p l i a n t
U S E P A N o n r o a d T i e r 2
S t a t i o n a r y ( 4 0 C F R 6 0 )
U S E P A N o n r o a d T i e r 3
c o m p l i a n t
U S E P A N o n r o a d T i e r 3
S t a t i o n a r y ( 4 0 C F R 6 0 )
C o o l i n g v a r i a n t
C o o l i n g p a c k a g e i n c l u d e d
E n g i n e m o d e l
Typical Rating Emissions Standard Cooling Engine
Generator Set
output (1)
60 Hz – 1800 rpm
1736 kWm - 3490 kWmGendrive enginesMission Critical Power (3H)
20 719 3Cooling Variants
A2A: air-to-air charge air cooling (TD)
W2A: water-to-air charge air cooling (TB)
(1) The quoted typical kVA / kWe ratings are based on typical generator
efficiencies.
The kVA figures are calculated with a 0.8 power factor.
Typical deductions for fan drive power and generator efficiency is appliedfor calculation and serves as guideline only.
reference to emission level in price list
M i s s i o n C r i t i c a l P o w e r - 6 0 H z
20 719 3
8/17/2019 3190171 MTU Gendrive SalesProgram
29/55
8/17/2019 3190171 MTU Gendrive SalesProgram
30/55
58 I Gendrive I Sales Program 2015 Sales Program 2015 I Gendrive I 59
kWe kVA kWm bhp
250 313 284 381 x x A2A x 6R 1600 G10S
275 344 312 418 x x A2A x 6R 1600 G20S
330 413 371 498 x x A2A x 8V 1600 G10S
365 456 408 547 x x A2A x 8V 1600 G20S
415 519 465 624 x A2A x 10V 1600 G10S
450 563 511 685 x x A2A x 10V 1600 G20S
500 625 561 752 x x A2A x 12V 1600 G10S
550 688 608 815 x x A2A x 12V 1600 G20S
640 800 710 952 x x A2A x 12V 2000 G45
640 800 710 952 x x W2A 12V 2000 G45
735 919 810 1086 x x A2A x 12V 2000 G85 (2)
735 919 810 1086 x x W2A 12V 2000 G85 (2)
830 1038 915 1227 x x A2A x 16V 2000 G45
830 1038 915 1227 x x W2A 16V 2000 G45
925 1156 1010 1354 x x A2A x 16V 2000 G85925 1156 1010 1354 x x W2A 16V 2000 G85
1100 1375 1191 1597 x x A2A x 18V 2000 G85
1100 1375 1191 1597 x x W2A 18V 2000 G85
F u e l c o n s u m p t i o n o p t i m i z e d
U S E P A N o n r o a d T i e r 2
c o m p l i a n t
U S E P A N o n r o a d T i e r 2
S t a t i o n a r y ( 4 0 C F R 6 0 )
U S E P A N o n r o a d T i e r 3
c o m p l i a n t
U S E P A N o n r o a d T i e r 3
S t a t i o n a r y ( 4 0 C F R 6 0 )
C o o l i n g v a r i a n t
C o o l i n g p a c k a g e i n c l u d e d
E n g i n e m o d e l
Typical Rating Emissions Standard Cooling Engine
Generator Set
output (1)
60 Hz – 1800 rpm
284 kWm - 1191 kWm
20 719 3
Gendrive enginesPrime Power (3B)
P r i m e P o w e r - 6 0 H z
20 719 3Cooling Variants
A2A: air-to-air charge air cooling (TD)
W2A: water-to-air charge air cooling (TB)
(1) The quoted typical kVA / kWe ratings are based on typical generator
efficiencies.
The kVA figures are calculated with a 0.8 power factor.
Typical deductions for fan drive power and generator efficiency is applied
for calculation and serves as guideline only.
(2) Series 12V 2000 G85 without power
reduction available up to 30°C / 400 m
reference to emission level in price list
8/17/2019 3190171 MTU Gendrive SalesProgram
31/55
60 I Gendrive I Sales Program 2015 Sales Program 2015 I Gendrive I 61
kWe kVA kWm bhp
1000 1250 1105 1482 x W2A 12V 4000 G73 (2)
1260 1575 1390 1864 x W2A 16V 4000 G73 (2)
1400 1750 1520 2038 x x x W2A 12V 4000 G43
1600 2000 1736 2328 x x x W2A 12V 4000 G83
1850 2313 2020 2709 x x x W2A 16V 4000 G43
2100 2625 2280 3058 x x x W2A 16V 4000 G83
2300 2875 2490 3339 x x x W2A 20V 4000 G43
2550 3188 2740 3674 x x x W2A 20V 4000 G83
2800 3500 3010 4036 x x x W2A 20V 4000 G83L
F u e l c o n s u m p t i o n o p t i m i z e d
U S E P A N o n r o a d T i e r 2
c o m p l i a n t
U S E P A N o n r o a d T i e r 2
S t a t i o n a r y ( 4 0 C F R 6 0 )
U S E P A N o n r o a d T i e r 3
c o m p l i a n t
U S E P A N o n r o a d T i e r 3
S t a t i o n a r y ( 4 0 C F R 6 0 )
C o o l i n g v a r i a n t
C o o l i n g p a c k a g e i n c l u d e d
E n g i n e m o d e l
Typical Rating Emissions Standard Cooling Engine
Generator Set
output (1)
60 Hz – 1800 rpm
1105 kWm - 3010 kWm
20 719 3
Gendrive enginesPrime Power (3B)
P r i m e P o w e r - 6 0 H z
20 719 3Cooling Variants
A2A: air-to-air charge air cooling (TD)
W2A: water-to-air charge air cooling (TB)
(1) The quoted typical kVA / kWe ratings are based on typical generator
efficiencies.
The kVA figures are calculated with a 0.8 power factor.Typical deductions for fan drive power and generator efficiency is applied
for calculation and serves as guideline only.
reference to emission level in price list
(2) 4000 G73 with 1200 rpm
8/17/2019 3190171 MTU Gendrive SalesProgram
32/55
62 I Gendrive I Sales Program 2015 Sales Program 2015 I Gendrive I 63
kWe kVA kWm bhp
1400 1750 1520 2038 x x x W2A 12V 4000 G43
1600 2000 1736 2328 x x x W2A 12V 4000 G83
1850 2313 2020 2709 x x x W2A 16V 4000 G43
2100 2625 2280 3058 x x x W2A 16V 4000 G83
2300 2875 2490 3339 x x x W2A 20V 4000 G43
2550 3188 2740 3674 x x x W2A 20V 4000 G83
2800 3500 3010 4036 x x x W2A 20V 4000 G83L
F u e l c o n s u m p t i o n o p t i m i z e d
U S E P A N o n r o a d T i e r 2
c o m p l i a n t
U S E P A N o n r o a d T i e r 2
S t a t i o n a r y ( 4 0 C F R 6 0 )
U S E P A N o n r o a d T i e r 3
c o m p l i a n t
U S E P A N o n r o a d T i e r 3
S t a t i o n a r y ( 4 0 C F R 6 0 )
C o o l i n g v a r i a n t
C o o l i n g p a c k a g e i n c l u d e d
E n g i n e m o d e l
Typical Rating Emissions Standard Cooling Engine
Generator Set
output (1)
60 Hz – 1800 rpm
1520 kWm - 3010 kWm
20 719 3Cooling Variants
A2A: air-to-air charge air cooling (TD)
W2A: water-to-air charge air cooling (TB)
(1) The quoted typical kVA / kWe ratings are based on typical generator
efficiencies.
The kVA figures are calculated with a 0.8 power factor.
Typical deductions for fan drive power and generator efficiency is applied
for calculation and serves as guideline only.
reference to emission level in price list
20 719 3
Gendrive enginesGrid Stability Power (3G)
G r i d S t a b i l i t y P o w e r - 6 0 H z
8/17/2019 3190171 MTU Gendrive SalesProgram
33/55
64 I Gendrive I Sales Program 2015 Sales Program 2015 I Gendrive I 65
kWe kVA kWm bhp
525 656 580 778 x A2A x 12V 2000 G45 (2)
525 656 580 778 x W2A 12V 2000 G45 (2)
550 688 620 831 x A2A x 12V 2000 G85 (2)
550 688 620 831 x W2A 12V 2000 G85 (2)
615 769 685 919 x A2A x 16V 2000 G45 (2)
615 769 685 919 x W2A 16V 2000 G45 (2)
715 894 790 1059 x A2A x 16V 2000 G85 (2)
715 894 790 1059 x W2A x 16V 2000 G85 (2)
790 988 870 1167 x W2A 12V 4000 G73 (3)
815 1019 900 1207 x A2A x 18V 2000 G85 (2)
815 1019 900 1207 x W2A 18V 2000 G85 (2)
1040 1300 1140 1529 x W2A 16V 4000 G73 (3)
1100 1375 1190 1596 x W2A 12V 4000 G43
1300 1625 1420 1904 x W2A 12V 4000 G83
1500 1875 1680 2253 x W2A 16V 4000 G431775 2219 1950 2615 x W2A 16V 4000 G83
2050 2563 2230 2990 x W2A 20V 4000 G83
2300 2875 2490 3339 x W2A 20V 4000 G83L
F u e l c o n s u m p t i o n o p t i m i z e d
U S E P A N o n r o a d T i e r 2
c o m p l i a n t
U S E P A N o n r o a d T i e r 2
S t a t i o n a r y ( 4 0 C F R 6 0 )
U S E P A N o n r o a d T i e r 3
c o m p l i a n t
U S E P A N o n r o a d T i e r 3
S t a t i o n a r y ( 4 0 C F R 6 0 )
C o o l i n g v a r i a n t
C o o l i n g p a c k a g e i n c l u d e d
E n g i n e m o d e l
Typical Rating Emissions Standard Cooling Engine
Generator Set
output (1)
60 Hz – 1800 rpm
580 kWm - 2490 kWm
20 719 3
Gendrive enginesContinuous Power (3A)
C o n t i n u o u s P o w e r - 6 0 H z
20 719 3Cooling Variants
A2A: air-to-air charge air cooling (TD)
W2A: water-to-air charge air cooling (TB)
(1) The quoted typical kVA / kWe ratings are based on typical generator
efficiencies.
The kVA figures are calculated with a 0.8 power factor.
Typical deductions for fan drive power and generator efficiency is applied
for calculation and serves as guideline only.
(2) Available on request
(3) 4000 G73 with 1200 rpm
Series 1600: Heavy duty base load ratings
(3A) on request
reference to emission level in price list
8/17/2019 3190171 MTU Gendrive SalesProgram
34/55
66 I Gendrive I Sales Program 2015 Sales Program 2015 I Gendrive I 67
kVA kWe kWe kVA kWm bhp kWm bhp
50 Hz 50 Hz 60 Hz 60 Hz 50 Hz 50 Hz 60 Hz 60 Hz
1800 1440 1600 2000 1575 2112 1736 2328 x W2A 12V 4000 G23/G43(3)
2000 1600 1750 2188 1750 2347 1910 2561 x W2A 12V 4000 G63/G83(3)
2250 1800 2100 2625 1965 2635 2280 3058 x W2A 16V 4000 G23/G43(3)
2500 2000 2300 2875 2185 2930 2500 3353 x W2A 16V 4000 G63/G83(3)
F u e l c o n s u m p t i o n o p t i m i z e d
E x h a u s t e m i s s i o n o p t i m i z e d ( T A - L u f t
) ( 2 )
U S E P A N o n r o a d T i e r 2
c o m p l i a n t
U S E P A N o n r o a d T i e r 2
S t a t i o n a r y ( 4 0 C F R 6 0 )
U S E P A N o n r o a d T i e r 3
c o m p l i a n t
U S E P A N o n r o a d T i e r 3
S t a t i o n a r y ( 4 0 C F R 6 0 )
N E A S i n g a p o r e f o r O R D E ,
c o m p l i a n t E P A T i e r 2
C o o l i n g v a r i a n t
C o o l i n g p a c k a g e i n c l u d e d
E n g i n e m o d e l
Typical Generator Set Rating Emissions Standard Cooling Engine
output (1)
50/60 Hz – 1500/1800 rpm
1575 kWm – 2500 kWmGendrive engines (switchable)Standby Power (3D)
20 719 350 Hz 60 Hz 50 Hz 60 Hz
Cooling Variants
A2A: air-to-air charge air cooling (TD)
W2A: water-to-air charge air cooling (TB)
(1) The quoted typical kVA / kWe ratings are based on typical
generator efficiencies.
The kVA figures are calculated with a 0.8 power factor.
Typical deductions for fan drive power and generator efficiency is applied
for calculation and serves as guideline only.
(2) Explanation see page 82
(3) Available on request
reference to emission level in price list
19 31 20 7 24
241
S t a n d b y P o w e r -
5 0 / 6 0 H z ( s w i t c h a b l e )
8/17/2019 3190171 MTU Gendrive SalesProgram
35/55
68 I Gendrive I Sales Program 2015 Sales Program 2015 I Gendrive I 69
kVA kWe kWe kVA kWm bhp kWm bhp
50 Hz 50 Hz 60 Hz 60 Hz 50 Hz 50 Hz 60 Hz 60 Hz
275 220 250 313 249 334 284 381 x A2A x 6R 1600 B30S
300 240 275 344 274 367 312 418 x A2A x 6R 1600 B40S
365 292 330 413 325 436 371 498 x A2A x 8V 1600 B30S
400 320 365 456 358 480 408 547 x A2A x 8V 1600 B40S
450 360 415 519 448 601 511 685 x A2A x 10V 1600 B40S
500 400 450 563 524 703 561 752 x A2A x 12V 1600 B30S
590 472 500 625 576 772 608 815 x A2A x 12V 1600 B40S
800 640 650 813 709 951 716 960 x (3) x (4) x (4) A2A x 12V 2000 B76
1000 800 910 1138 890 1194 998 1338 x (3) x (4) x (4) A2A x 16V 2000 B76
1250 1000 1000 1250 1102 1478 1097 1471 x (3) x (4) x (4) A2A x 18V 2000 B76
1600 1280 1400 1750 1420 1904 1520 2038 x x W2A 12V 4000 G23/G43
1600 1280 1400 1750 1420 1904 1520 2038 x(3), (5) x(4), (5) W2A 12V 4000 G23/G43
1800 1440 1600 2000 1575 2112 1736 2328 x(5) x(4), (5) W2A 12V 4000 G63/G83
2100 1680 1850 2313 1798 2411 2020 2709 x W2A 16V 4000 G23/G43
2100 1680 1850 2313 1798 2411 2020 2709 x(3), (5) x(4), (5) W2A 16V 4000 G23/G43
2250 1800 2100 2625 1965 2635 2280 3058 x W2A 16V 4000 G63/G83
2250 1800 2100 2625 1965 2635 2280 3058 x(3), (5) x(4), (5) W2A 16V 4000 G63/G83
Cooling Variants
A2A: air-to-air charge air cooling (TD)
W2A: water-to-air charge air cooling (TB)
(1) The quoted typical kVA / kWe ratings are based on typical generator
efficiencies.
The kVA figures are calculated with a 0.8 power factor.
Typical deductions for fan drive power and generator efficiency is applied
for calculation and serves as guideline only.
(2) Explanation see page 82
(3) Only 60 Hz
(4) Only 50 Hz
(5) Available on request
F u e l c o n s u m p t i o n o p t i m i z e d
E x h a u s t e m i s s i o n o p t i m i z e d ( T A - L u f t
) ( 2 )
U S E P A N o n r o a d T i e r 2
c o m p l i a n t
U S E P A N o n r o a d T i e r 2
S t a t i o n a r y ( 4 0 C F R 6 0 )
U S E P A N o n r o a d T i e r 3
c o m p l i a n t
U S E P A N o n r o a d T i e r 3
S t a t i o n a r y ( 4 0 C F R 6 0 )
N E A S i n g a p o r e f o r O R D E ,
c o m p l i a n t E P A T i e r 2
C o o l i n g v a r i a n t
C o o l i n g p a c k a g e i n c l u d e d
E n g i n e m o d e l
Typical Generator Set Rating Emissions Standard Cooling Engine
output (1)
Gendrive engines (switchable)Prime Power (3B)
50 / 60 Hz – 1500/1800 rpm
249 kWm – 2280 kWm
50 Hz 60 Hz 50 Hz 60 Hz 1 20 7 2419 3
reference to emission level in price list
19 31 20 7 24
P r i m e P o w e r - 5 0 / 6 0 H z ( s
w i t c h a b l e )
8/17/2019 3190171 MTU Gendrive SalesProgram
36/55
70 I Gendrive I Sales Program 2015 Sales Program 2015 I Gendrive I 71
kVA kWe kWe kVA kWm bhp kWm bhp
50 Hz 50 Hz 60 Hz 60 Hz 50 Hz 50 Hz 60 Hz 60 Hz
1485 1188 1300 1625 1310 1757 1420 1904 x W2A 12V 4000 G63/G83(3)
1865 1492 1775 2219 1635 2193 1950 2615 x W2A 16V 4000 G63/G83(3)
F u e l c o n s u m p t i o n o p t i m i z e d
E x h a u s t e m i s s i o n o p t i m i z e d ( T A - L u f t
) ( 2 )
U S E P A N o n r o a d T i e r 2
c o m p l i a n t
U S E P A N o n r o a d T i e r 2
S t a t i o n a r y ( 4 0 C F R 6 0 )
U S E P A N o n r o a d T i e r 3
c o m p l i a n t
U S E P A N o n r o a d T i e r 3
S t a t i o n a r y ( 4 0 C F R 6 0 )
N E A S i n g a p o r e f o r O R D E ,
c o m p l i a n t E P A T i e r 2
C o o l i n g v a r i a n t
C o o l i n g p a c k a g e i n c l u d e d
E n g i n e m o d e l
Typical Generator Set Rating Emissions Standard Cooling Engine
output (1)
50 /60 Hz – 1500/1800 rpm
1310 kWm – 1950 kWmGendrive engines (switchable)Continuous Power (3A)
50 Hz 60 Hz 50 Hz 60 Hz
Cooling Variants
A2A: air-to-air charge air cooling (TD)
W2A: water-to-air charge air cooling (TB)
(1) The quoted typical kVA / kWe ratings are based on typical
generator efficiencies.
The kVA figures are calculated with a 0.8 power factor.
Typical deductions for fan
Recommended