2
Why Strata? 2 Revolutionary Sorbents 3 strata-X 3
strata-X-C 7
Screening Drugs of Abuse 11 Strata Screen-C 11
Strata Screen-A 11
Strata Screen-C GF 11
Method Development 13
Phase Descriptions 15 Reversed Phases 15
Normal Phases 16
Ion Exchange Phases 17
Ordering Information 18 Strata SPE Tubes 18
Large Format SPE 19
High-Throughput SPE 20 96-Well Plates 20
Bulk SPE 21
Sepra 21
Sample Processing Stations 22
SPE Accessories 22
Table of contents
?DEEN
PLE
H
Phenomenex technical consultants are available to help with your SPE method development. Please feel free to contact us or visit www.phenomenex.comfor SPE:
n Troubleshooting
n Technical Solutions
n Converting Liquid/LiquidExtraction to SPE
n Method Optimization
Tel: 310-212-0555 Fax: 310-328-7768 Web: www.phenomenex.com
2
Why Strata™?
If Strata SPE or Sepra Bulk products do not perform as well or better than your current SPE product of similar phase, mass and size, send in your comparative data within 45 days and keep the Strata SPE products or Sepra Bulk for FREE!
Rugged The unique manufacturing process makes sorbents extremely rugged and
provides consistently high recoveries for a wide range of applications.
ReproducibleSophisticated characterization techniques are used to ensure high
efficiencies and invariable masses from lot-to-lot resulting in highly
reproducible sorbents.
RevolutionaryThe Strata line is comprised of ultra-pure sorbents, which are designed
to give high recoveries for traditional SPE applications such as Strata
C18, and revolutionary, deconditioning resistant, sorbents that streamline
the method development process and redefine the limits of SPE such
as strata-X and strata-X-C.
GuaranteedA comprehensive certificate of analysis is included in every box. QC data
obtained throughout the production process is documented to provide
complete traceability and ensure guaranteed quality.
What More Could You Ask For?
Tel: 310-212-0555 Fax: 310-328-7768 Web: www.phenomenex.com
3
P
P
P
P
P
Feature strata-X C18Styrene-divinylbenzene
polymer
Surface Chemistry
Surface modified styrene-divinylbenzene polymer
Silica particle functionalized with C18 Highly crosslinked polymer
Retention Mechanism
Hydrophobic, H-bonding, andAromatic
Hydrophobic Hydrophobic and Aromatic
Hydrogen donating characteristics
Slightly acidic surface, shows a strong interaction with basic compounds
None None
Resistant to deconditioning
Yes, can run dry without negatively impacting retention
No No
Water-wettable Yes No No
Analyte Capacity 10-15% of sorbent bed mass 1-5% of sorbent bed mass 10-15% of sorbent bed mass
VersatilityEnhanced polar analyte retention compliments ability to extract hydrophobic compounds
Extracting hydrophobic compounds
Extracting hydrophobic compounds
Polymeric Reversed Phase Sorbent for Extraction of Acidic, Basic and Neutral Compounds
strata-X is a patent pending versatile sorbent that can be used to separate both polar and non-polar compounds. This revolutionary technology consists of hydrophilic, hydrophobic, and aromatic retention mechanisms that offer the following benefits:
• Strong π−π retention mechanism that provides high recoveries for aromatic compounds
• Deconditioning resistant sorbent bed that can run dry without losing selectivity
• Enhanced polar selectivity for polar metabolites
X-SPEct More from strata-X strata-X vs. Traditional SPE Sorbents.
Improved Recovery for Aromatics
strata-X is a water-wettable, surface modified styrene-divinylbenzene polymer which retains analytes by π−π interaction, giving high recoveries for aromatic compounds. Elution solvents that have strong π character such as acetonitrile can be used to disrupt the π−π interaction of the sorbent and analyte.
strata-X Ordering Information: p. 6
π electron density of aromatic
analyte
π electron density of strata-X
Sorbent Characteristics
Particle Size 33µm
Pore Size 85Å
Surface Area 800m2/g
pH stability 1-14
Tel: 310-212-0555 Fax: 310-328-7768 Web: www.phenomenex.com
Put A Stop To Stopcocks
The deconditioning resistant sorbent bed eliminates the need to adjust stop-cocks on a vacuum manifold during manual tube processing, and eliminates the well–to-well variability that often results from 96-well plate automation.
Maintains High Recovery Even After Vacuum Dried for 10 minutes!
The strata-X Method for Reversed Phase ExtractionVolumes suggested are for a 30mg bed mass.
4
CH3OHCH3OH
Analyte elutes!
5% CH3OH + H2O5% CH3OH + H2O
Impurities eluteoff the sorbent!
Analyte
Impurities
H2O + CH3OHH2O + CH3OH
H2OCH3OHCH3OH CH3OHCH3OH
Analyte elutes!
5% CH3OH + H2O5% CH3OH + H2O
Impurities eluteoff the sorbent!
Analyte
Impurities
H2O + CH3OHH2O + CH3OH
H2OCH3OHCH3OH CH3OHCH3OH
Analyte elutes!
5% CH3OH + H2O5% CH3OH + H2O
Impurities eluteoff the sorbent!
Analyte
Impurities
H2O + CH3OHH2O + CH3OH
H2OCH3OHCH3OH CH3OHCH3OH
Analyte elutes!
5% CH3OH + H2O5% CH3OH + H2O
Impurities eluteoff the sorbent!
Analyte
Impurities
H2O + CH3OHH2O + CH3OH
H2OCH3OHCH3OH
DoxepinRanitidine
CaffeineTheophylline Procainamide
Silica-basedC18
��
���
��
��
��
��
��
��
��
��
�
������������������
�� � � � ��
���
����
���
strata-X Ordering Information: p. 6
Conditions:Tubes: 30mg/1mL strata-X, 100mg/1mL Strata C18-E
Sample: Analytes spiked in phosphate buffer saline (PBS) solution at concentration of 1µg/mL, n=3
Method: The strata-X method was used. After the conditioning step the sorbent was dried under vacuum up to 10 min. Percent recoveries were determined by HPLC analysis.
Conditions:Method: Analysis spiked in porcine serum at concentration of 0.5 or 1.0µg/mL. The strata-X method was used, see above. Contact Phenomenex for more complete method details.
1.Condition
with 1mL methanol
2.Equilibratewith 1mL water
3.Load Sample
4.Wash Impuritieswith 1mL 5% methanol
in water and dry 30 sec. at full vacuum
5.Elute Analyte!with 1mL methanol
or 50:50 acetonitrile/ methanol
Relative Recovery of Acidic, Basic, and Neutral Compounds
CH3OHCH3OH
Analyte elutes!
5% CH3OH + H2O5% CH3OH + H2O
Impurities eluteoff the sorbent!
Analyte
Impurities
H2O + CH3OHH2O + CH3OH
H2OCH3OHCH3OH
Tel: 310-212-0555 Fax: 310-328-7768 Web: www.phenomenex.com
5
�������������������������������
��������������
����������������������
���������������������������
�����������������������������������������������������������������
���������������������
�������������������������
�����������������
���������������������
���������������������������
���������������������������
����������
�������������
��������������
�������������������
��
���
��
��
��
�
���
����
���
strata-X Desalting Method
Polarity Scale Log P* Compounds % Recovery
PolarPolarPolarPolar
-0.78-0.07-0.020.46
TheobromineCaffeine
TheophyllineAcetaminophen
99969896
Moderately PolarModerately Polar
1.462.15
Phenol2-Chlorophenol
9597
Non-PolarNon-Polar
4.134.29
2,4,6-TribromophenolDoxepin
10193
Flexibility for a Wide Range of Applications
The surface chemistry of the strata-X sorbent allows for very selective interactions between the sorbent surface and analyte, resulting in versatility for a wide range of applications, as illustrated in the example below.
Selective Elution and Desalting of Peptides
Enhanced Polar Selectivity Great for the extraction of polar metabolites and non-polar parent compounds!
*Log P is the partition coefficient that can be used to determine the polarity of a compound.
An example of the compounds that can be retained by strata-X!
�������������������������������
��������������
����������������������
���������������������������
�����������������������������������������������������������������
���������������������
�������������������������
�����������������
���������������������
���������������������������
���������������������������
����������
�������������
��������������
�������������������
��
���
��
��
��
�
���
����
���
strata-X Ordering Information: p. 6
OH
BrBr
Br
OH
OH
Cl
O
N
Phenol
2-Chlorophenol
Doxepin Caffeine Theophylline
2,4,6-TribromophenolTheobromine
NO
NN
O
N
NH
N
O
N
NO
N
N
O
NO
NH
Tel: 310-212-0555 Fax: 310-328-7768 Web: www.phenomenex.com
6
1mL (100/box) 3mL (50/box) 6mL (30/box)
Phase 30mg 60mg 200mg 500mg 100mg 200mg 500mg
strata-X 8B-S100-TAK 8B-S100-UBJ 8B-S100-FBJ 8B-S100-HBJ 8B-S100-ECH 8B-S100-FCH 8B-S100-HCH
Note: tube sizes not proportional nor actual size.
• Extraction of Phenols from Water using
strata-X (TN-001)
• Extraction of Nitroanilines from Water
using strata-X (TN-003)
• Extraction of Acidic, Basic, and Neutral
Compounds using strata-X (TN-004)
• TCAs Extracted from Serum using
strata-X (TN-006)
• Fast Extraction of Acyclovir from Plasma
using strata-X On-line Cartridge (TN-009)
Ordering Information
strata-X Tubes
strata-X 96-Well plates (2/Box)
Phase 5mg 10mg 30mg 60mg
strata-X 8E-S100-NGB 8C-S100-AGB 8E-S100-TGB 8E-S100-UGB
strata-X On-Line Extraction Cartridge
Order No. Dimensions Unit/Box Price
00M-S033-B0-CB strata-X on-line extraction cartridge, 25µm, 20 x 20mm
ea
CH0-5845 Cartridge holder, 20mm ea
Technical Notes Available Contact your Phenomenex Distributor and Request A Technical Note Today.
Tel: 310-212-0555 Fax: 310-328-7768 Web: www.phenomenex.com
Feature strata-X-C Silica-Based Mixed-Mode
Surface Chemistry
Styrene-divinylbenzene polymer surfaced modified with a strong cation exchanger group
Functionalized silica particles (Alkyl chain + SCX)
Retention Mechanism
Hydrophobic, H-bonding, Aromatic and Ionic
Hydrophobic and Ionic
Resistant to deconditioning
Yes, can run dry without negatively impacting retention
No
pH Stability 1-14 2-7.5
Versatility
Multimode retention mechanism gives enhanced recoveries for all 1°, 2°, and 3° amines including those with aromatic and polar character
Traditionally used for 1°, 2°, and 3° amines
7
New Phase
Polymeric Cation Exchange Sorbent for Extraction of Basic Compounds
strata X-C is a patent pending sorbent that gives extremely high recoveries for bases using the strong interaction of ion exchange. The revolutionary selectivity of strata X-C offers significant advantages over silica-based cation exchange sorbents:
• Mixed-mode functionality includes π−π selectivity for aromatic bases and cation exchange selectivity for primary, secondary and tertiary amines
• Strong secondary interactions eliminate the use of
halogenated solvents when cleaning up drugs of abuse
• Deconditioning resistant sorbent that can run dry without losing ion exchange selectivity
• Ability to fractionate acidic and neutral components from bases
• 100% organic washes provide cleaner extracts from biological samples reducing ion suppression
X-SPEct More from strata-X-C strata-X-C vs. Silica-Based Mixed-Mode Sorbents.
Sorbent Characteristics
Particle Size 33µm
Pore Size 85Å
Surface Area 800m2/g
pH Stability 1-14
Ionic Capacity 1meq/g
strata-X-C Ordering Information: p. 10Tel: 310-212-0555 Fax: 310-328-7768 Web: www.phenomenex.com
8
New Phase
strata-X-C Method for THC
*After elution samples are reconstituted and derivatized, then analyzed on a GC/MS using a Zebron™ ZB-5. Contact Phenomenex for additional details about this method.
strata-X-C Ordering Information: p. 10
Strong Secondary Interactions Eliminate the Use of Halogenated SolventsSpecialized Extraction of THC from Urine on strata-X-C.
�
����
���
���
���
���
� ��
��
��
����
������������
�
����
���
��
���
THC-COOHTHC-COOH Glucuronide
(Base Hydrolysis)
Acrylamide
Verapamil
Doxepin
Naproxen
Diphenhydramine
Chlorpheniramine
Diazepam
Flunitrazepam
Flurazepam
Bromazepam
Pseudoephedrine
Phenylpropanolamine
Acetaminophen
Codeine
Metoprolol
Propranolol
Phencyclidine
Methadone
Methamphetamine
Neurotoxin
Antidepressant
TCA
NSAID
Antihistamine
Benzodiazepine
Decongestant
Analgesic
Beta Blockers
Drugs of Abuse
0 20 40 60 80 100
% Recovery
% Recovery for a Wide Range of Analytes on
strata-X-C
High Recoveries for Basic Compounds
1 Conditionwith 2mL methanol
2 Equilibratewith 2mL 0.1N HCl
3 LoadHydrolyzed samples
4 Wash 12mL 0.1N HCl
5Wash 2
2mL 0.1N HCl/acetonitrile 70:30* dry for 4 minutes
6Wash 3
200µL glacial acetic acid, let it percolate
under gravity 30-40 sec dry 1min
7 Elute2mL 2% glacial acetic acid in acetonitrile
5% NH4OH+ CH3OH5% NH4OH+ CH3OH
Analyte elutes!
0.1% H3PO40.1% H3PO4
Impurities eluteoff the sorbent!
CH3OHCH3OH
Impurities eluteoff the sorbent!
Analyte
Impurities
H2O + CH3OHH2O + CH3OH
H2OCH3OHCH3OH
5% NH4OH+ CH3OH5% NH4OH+ CH3OH
Analyte elutes!
0.1% H3PO40.1% H3PO4
Impurities eluteoff the sorbent!
CH3OHCH3OH
Impurities eluteoff the sorbent!
Analyte
Impurities
H2O + CH3OHH2O + CH3OH
H2OCH3OHCH3OH
5% NH4OH+ CH3OH5% NH4OH+ CH3OH
Analyte elutes!
0.1% H3PO40.1% H3PO4
Impurities eluteoff the sorbent!
CH3OHCH3OH
Impurities eluteoff the sorbent!
Analyte
Impurities
H2O + CH3OHH2O + CH3OH
H2OCH3OHCH3OH
5% NH4OH+ CH3OH5% NH4OH+ CH3OH
Analyte elutes!
0.1% H3PO40.1% H3PO4
Impurities eluteoff the sorbent!
CH3OHCH3OH
Impurities eluteoff the sorbent!
Analyte
Impurities
H2O + CH3OHH2O + CH3OH
H2OCH3OHCH3OH
CH3COOHCH3COOH
Analyte elutes!
0.1N HCL0.1N HCL
Impurities eluteoff the sorbent!
0.1N HCL +ACN0.1N HCL +ACN
Impurities eluteoff the sorbent!
CH3COOH +ACNCH3COOH +ACN
Impurities elute!
Analyte
Impurities
0.1N HCLCH3OHCH3OH
CH3COOHCH3COOH
Analyte elutes!
0.1N HCL0.1N HCL
Impurities eluteoff the sorbent!
0.1N HCL +ACN0.1N HCL +ACN
Impurities eluteoff the sorbent!
CH3COOH +ACNCH3COOH +ACN
Impurities elute!
Analyte
Impurities
0.1N HCLCH3OHCH3OH
CH3COOHCH3COOH
Analyte elutes!
0.1N HCL0.1N HCL
Impurities eluteoff the sorbent!
0.1N HCL +ACN0.1N HCL +ACN
Impurities eluteoff the sorbent!
CH3COOH +ACNCH3COOH +ACN
Impurities elute!
Analyte
Impurities
0.1N HCLCH3OHCH3OH
Class of Compounds
The mixed-mode functionality and wide pH range of this sorbent make strata-X-C extremely versatile for toxicological and phar-maceutical analyses.
Tel: 310-212-0555 Fax: 310-328-7768 Web: www.phenomenex.com
New Phase
9
Ion suppression study performed with post column infusion of Atenolol, positive ESI mode m/z 267. Contact Phenomenex for additional method details.
���
�����������
���
���
���
� � � � � � � ����������
��������������������������������������������������������������������������������
����������
strata-X-C Ordering Information: p. 10
��
��
�
� �����������������������������������������������
��������������������������������������������������������������������������������������
����������������������������������
SPE Conditions: Tubes: 60mg/3mLMethod: The IS (5.0µg/mL) for acidic and neutral drugs was spiked with analytes in PBS before loading onto the tube. The ext. std. (50.0µg/mL) for basic drugs was added to elution 2 before evaporation.
HPLC Conditions: Luna® C18(2) Column was used. Contact Phenomenex for details.
Complete Removal of Biological Contaminants The strong ion exchange mechanism allows for aggressive washes with 100% organic solvents with no loss in recovery for analytes. This allows for the complete removal of components, which may cause ion suppression on a MS.
Reduce Ion Suppression with strata-X-C
Selective Recovery of Bases from Acidic and Neutral Components
The revolutionary mixed-mode selectivity of strata-X-C may be used to fractionate basic compounds from acidic and neutral components. This is especially useful for applications that may require selective elution of acidic, neutral and basic compounds.
Fractionation on strata-X-C
The strata-X-C MethodVolumes suggested are for a 60mg bed mass.
5% NH4OH+ CH3OH5% NH4OH+ CH3OH
Analyte elutes!
0.1% H3PO40.1% H3PO4
Impurities eluteoff the sorbent!
CH3OHCH3OH
Impurities eluteoff the sorbent!
Analyte
Impurities
H2O + CH3OHH2O + CH3OH
H2OCH3OHCH3OH
*Go Slow; Flow rate not to exceed 2 mL/min. The extract of this method is volatile and can be lost during evaporation.
1.Condition
with 2mL methanol
2.Equilibratewith 2mL water
3.Load Sample
acidified with 20µL H3PO4/mL
4.Wash Impuritieswith 2mL 0.1% H3PO4
and dry 1-3min*
5.Removal of
Neutral & Acidic Components
with 2mL methanol
6.Elute Analyte!
with 2mL 5% NH4OH/methanol
5% NH4OH+ CH3OH5% NH4OH+ CH3OH
Analyte elutes!
0.1% H3PO40.1% H3PO4
Impurities eluteoff the sorbent!
CH3OHCH3OH
Impurities eluteoff the sorbent!
Analyte
Impurities
H2O + CH3OHH2O + CH3OH
H2OCH3OHCH3OH 5% NH4OH+ CH3OH5% NH4OH+ CH3OH
Analyte elutes!
0.1% H3PO40.1% H3PO4
Impurities eluteoff the sorbent!
CH3OHCH3OH
Impurities eluteoff the sorbent!
Analyte
Impurities
H2O + CH3OHH2O + CH3OH
H2OCH3OHCH3OH
���
�����������
���
���
���
� � � � � � � ����������
��������������������������������������������������������������������������������
����������
5% NH4OH+ CH3OH5% NH4OH+ CH3OH
Analyte elutes!
0.1% H3PO40.1% H3PO4
Impurities eluteoff the sorbent!
CH3OHCH3OH
Impurities eluteoff the sorbent!
Analyte
Impurities
H2O + CH3OHH2O + CH3OH
H2OCH3OHCH3OH 5% NH4OH+ CH3OH5% NH4OH+ CH3OH
Analyte elutes!
0.1% H3PO40.1% H3PO4
Impurities eluteoff the sorbent!
CH3OHCH3OH
Impurities eluteoff the sorbent!
Analyte
Impurities
H2O + CH3OHH2O + CH3OH
H2OCH3OHCH3OH 5% NH4OH+ CH3OH5% NH4OH+ CH3OH
Analyte elutes!
0.1% H3PO40.1% H3PO4
Impurities eluteoff the sorbent!
CH3OHCH3OH
Impurities eluteoff the sorbent!
Analyte
Impurities
H2O + CH3OHH2O + CH3OH
H2OCH3OHCH3OH
Tel: 310-212-0555 Fax: 310-328-7768 Web: www.phenomenex.com
10
Note: tube sizes not proportional nor actual size.
• Rapid Removal of Acrylamide from French
Fries using strata-X-C (TN-007)
• Basic Drugs from Biological Matrices on
strata-X-C (TN-008)
• Extraction of Sulfa Drugs from Plasma
using strata-X-C (TN-010)
Ordering Information
strata-X-C Tubes
strata-X-C 96-Well plates (2/Box)
1mL (100/box) 3mL (50/box) 6mL (30/box)
Phase 30mg 60mg 200mg 500mg 100mg 200mg 500mg
strata-X-C 8B-S029-TAK 8B-S029-UBJ 8B-S029-FBJ 8B-S029-HBJ 8B-S029-ECH 8B-S029-FCH 8B-S029-HCH
Phase 10mg 30mg 60mg
strata-X-C 8E-S029-AGB 8E-S029-TGB 8E-S029-UGB
New Phase
Technical Notes Available Contact your Phenomenex Distributor and Request A Technical Note Today.
Tel: 310-212-0555 Fax: 310-328-7768 Web: www.phenomenex.com
THC-COOH Recovery Comparison Cocaine Metabolite Recovery Comparison
Screen C is a great alternative to Varian Bond Elut Certify®, ISOLUTE® Confirm™ HCX, J.T. Baker narc-2™, Worldwide Monitoring® Clean Screen™ DAU*
Screen A is a great alternative to Varian Bond Elut Certify® II, ISOLUTE® Confirm™ HAX, J.T. Baker narc-1™, Worldwide Monitoring® Clean Screen™ THC*
���
��
��
��
�
�����
�����
���������������� �������������������������
���������������������
����������������������������������
���
��
��
��
�
���
����
���
��������
���������������������������������������������������������������������������������������������������
�����������������������������������������
Figure 2. Percent absolute recovery of a wide spectrum of analytes by Strata™ Screen-C GF. Contact Phenomenex for details concerning this method.
Figure 1. Average flow time of porcine serum (diluted 1:1 with PBS buffer) under gravity flow. Flow rate of Strata™ Screen-C GF is 70% and 270% faster than those of Xtrackt® and Certify HF®, respectively.
��
���
���
��
��
��
�
���
����
���
����
����
������� ��� ����������������� �������� �����������
�������������
��������������������
������������
��
���
��
��
��
�
���
����
���
�������������������������������
���������
Strata™ Screen-A & C
Extraction of Drugs of Abuse
Strata Screen-A and Screen-C silica-based sorbents combine hydrophobic retention of a C8 ligand plus a strong ion exchanger. The dual selectivity of these sorbents works well for extracting acidic and basic drugs of abuse from biological matrices such as serum and urine.
Strata Screen-C GF (Gravity Flow)
Strata Screen-C GF is a 200µm particle, mixed-mode sorbent that can be used to effectively clean up viscous samples and provide the following benefits:
• Superior flow in absence of a vacuum
• High extraction efficiency in comparison to traditional mixed- mode sorbents of smaller particle size
• Extraction of acidic, neutral and basic drugs
11
*Contact Phenomenex for details concerning this method.
Gravity Flow Comparison Recovery of a Wide Spectrum of Analytes
Tel: 310-212-0555 Fax: 310-328-7768 Web: www.phenomenex.com
Ordering Information
Strata Screen-A and Screen-C Tubes (for drugs of abuse)
1mL (100/box) 3mL (50/box) 6mL (30/box)
Phase 100mg 100mg 150mg 200mg 300mg 500mg 150mg 200mg 500mg
Screen-CScreen-A
8B-S016-EAK8B-S019-EAK
8B-S016-EBJ —
8B-S016-SBJ—
8B-S016-FBJ8B-S019-FBJ
8B-S016-RBJ—
——
8B-S016-SCH—
——
8B-S016-HCH8B-S019-HCH
Screen-C GF — — — 8B-S026-FBJ — 8B-S026-HBJ — 8B-S026-FCH 8B-S026-HCH
Note: tube sizes not proportional nor actual size.
Strata™ Screen-A & C
12
Strata Screen-A and Screen-C 96-Well plates (2/Box) Phase 25mg 50mg
Screen-C 8E-S016-CGB 8E-S016-DGB
Screen-A 8E-S019-CGB 8E-S019-DGB
• Extraction of Amphetamines from Urine using Strata Screen-C (ER-001)
• Extraction of Cocaine and Benzoylecgonine from Urine using Strata Screen-C (ER-002)
• Extraction of Opiates from Urine using Strata Screen-C (ER-003)
• Extraction of PCP from Urine using Strata Screen-C (ER-004)
• Extraction of 6-MAM from Urine using Strata Screen-C (TN-005)
• Extraction of THC-COOH from Urine using Strata Screen-A (ER-006)
Technical Notes Available Contact your Phenomenex Distributor and Request A Technical Note Today.
Tel: 310-212-0555 Fax: 310-328-7768 Web: www.phenomenex.com
Pore Size: the average diameter of the porous opening on the surface of a solvent particle.For a compound to be extracted in a SPE method, the molecule must not be too large to fit into the pores. For large molecules, sorbents with extra large pores must be used.
Bed Volume: the sum of the interstitial volume plus the pore volume of the sorbent.The bed volume of the sorbent determines the solvent volumes required in a SPE method. In general, solvent volumes between 4 to 8 times the bed volume are typically necessary to ensure proper conditioning, washing and elution. Conditioning with less than 4 to 8 bed volumes increases the risk of incomplete solvation of the bed and low or irreproducible recoveries, while more than 4 bed volumes is typically unnecessary.
Conventional packed bed, silica-based SPE products typically have a bed volume of approximately 150µL per 100mg of sorbent. Polymeric sorbents require larger solvent volumes for proper conditioning, washing and eluting. It is recommended to use 200-250µL per 100mg of sorbent.
Reservoir = Sample Capacity (i.e. 1mL, 3mL, 6mL, 12mL, 20mL, 60mL)
The column volume refers to the dimensions of the SPE tube. It determines the largest volume solvent or sample that can be delivered per aliquot.
Since the majority of SPE is performed on relatively “dirty” samples that contain many potential contaminants, it is common practice to be conservative and choose a slightly larger sorbent mass.
Determining Proper Bed MassSilica-based sorbents Non-ionic sorbents retain a mass of solute (analyte plus retained contaminants) that is equivalent to approximately 5% of the sorbent mass. Therefore, a 100mg cartridge can retain approximately 5mg of total solute mass.
Polymeric sorbents The large surface area of polymers give a higher capacity that is approximately 10-15% of the sorbent mass.
Ion exchange sorbents Capacity is determined by the number of charged sites on the sorbent available to interact with the analyte.
Sorbent Bed Mass = Analyte Capacity(i.e. 30mg, 50mg, 60mg, 100mg, 150mg, 200mg, 500mg, 1g, 2g, 5g, 10g, 20g)
The sorbent bed mass determines the maximum amount of analyte that can be retained by the sorbent.
Reduce breakthrough by selecting the proper bed mass!
?DEEN
PLE
H
Phenomenex technical consultants are available to help with your SPE method development. Please feel free to contact us or visit www.phenomenex.comfor SPE:
n Troubleshooting
n Technical Solutions
n Converting Liquid/LiquidExtraction to SPE
n Method Optimization
Selecting the Proper Tube
13 Tel: 310-212-0555 Fax: 310-328-7768 Web: www.phenomenex.com
Sorbent Selection
What exactly is my compound?
Separation Modes
aqueous
water
ionic
organic
organic
neutral
organic
neutral
nonpolar
reversedphase
strata-X
SDB-L
C18
C8
PH
(+)basic
ionexchange
strata-X-C
SCX
WCX
Screen-C
Screen-C GF
(-)acidic
ionexchange
SAX
NH2
Screen-A
polar
reversedphase*
strata-X
CN
neutral
moderatelypolar
reversedphase
strata-X
C8
CN
nonpolar
reversedphase
strata-X
SDB-L
C18
C8
PH
moderatelypolar
normalphase
Si-1
NH2
polar
normalphase
CN
Si-1
FL-PR
NH2
(+)basic
ionexchange
strata-X-C
SCX
WCX
Screen-C
Screen-C GF
(-)acidic
ionexchange
SAX
NH2
Screen-A
ionic
SeparationMode:
Selecting the Proper Strata Phase
*Note: These can be difficult to extract. Consider non-retentive reversed phase to remove interference.
SPE ReferenceManual & User GuideCD-Rom VersionOrder No.: AA0-6068Price:Hard Copy VersionOrder No.: AA0-6067
Price:
Polar compounds that have a log P value <1, example: Caffeine (log P= -0.07)
Moderately Polarcompounds that have a log P value between 1 and 3, example: Phenol (log P=1.46)
Non-Polarcompounds that have a log P value >3, example: Doxepin (log P = 4.29)
N
N N
N
O
O
N
O
OH
Do not know the log P values of your compound? Visit : http://esc.syrres.com/interkow/physdemo.htm
14
Mechanism Typical Application
Reversed Phase Extraction of hydrophobic or polar organic analytes from aqueous matrix
Normal Phase Extraction of polar analytes from non-polar organic solvents
Ion Exchange Extraction of charged analytes from aqueous or non-polar organic samples
Tel: 310-212-0555 Fax: 310-328-7768 Web: www.phenomenex.com
strata-X (patent pending)Selectivity: this revolutionary, patent-pending, polymeric SPE sorbent has numerous retention mechanisms, including hydropho-bic, hydrophilic and π-π interactions.
• General screening for acidic, neutral and basic organic compounds in same sample.
• Extracting a non-polar parent compound along with its more polar metabolite in same sample.
• Enhanced retention and clean up of polar compounds.
• Great starting point for all reversed phase applications
C18-ESelectivity: nonspecific non-polar retention mechanism with the surface end-capped to minimize secondary polar silanolinteractions.
• Extraction of hydrophobic molecules from aqueous and biological samples.
• Desalting a matrix, as ions are not retained by the sorbent.
• Separate large proteins from drugs. The drugs can be extracted from a sample, while macromolecules >15kD are too large to effectively interact with the sorbent.
C18-USelectivity: primarily non-polar retention mechanismcombined with secondary polar silanol interactions.
• Increased extraction efficiency and enhanced clean up of hydrophobic compounds that contain hydroxy or amine functional groups from water or biological fluids.
• Desalting a matrix.
• Separate large proteins from polar drugs or metabolites. The drugs can be extracted from a sample, while macromolecules >15kD are too large to effectively interact with the sorbent.
C18-T (wide pore)Selectivity: nonspecific non-polar retention mechanism withthe surface end-capped to minimize secondary polar silanolinteractions.
• Extracting large hydrophobic molecules (up to 75kD) from water or biological matrices.
• Desalting a matrix.
• Separate large proteins from drugs. The drugs can be extracted from a sample, while macromolecules >74kD are too large to effectively interact with the sorbent.
C8Selectivity: nonspecific non-polar retention mechanism with the surface end-capped to minimize secondary polar silanolinteractions.
• Extracting hydrophobic compounds from water or biological fluids that are retained too strongly on Strata C18-E or
strata-X.
PhenylSelectivity: unique non-polar retention mechanism via π-π andhydrophobic interactions.
• Extracting aromatic hydrophobic compounds.
CNSelectivity: unique selectivity toward non-polar and polarcompounds combined with secondary polar silanol interactions.
• Retaining non-polar, compounds that are retained too strongly on Strata C18-E or C8.
• A normal phase sorbent used to extract polar compounds from non-polar sorbents.
SDB-L (Styrene-divinylbenzene)Selectivity: combines non-polar retention mechanism via π-π and hydrophobic interactions completely free from secondary silanol interactions.
• Extraction of non-polar and polar molecules.
• Large volume environmental samples.
• Extracting large proteins (up to 90kD), which can effectively interact with the large pores of the sorbent, making it useful in applications such as desalting a sample.
Reversed Phases
Reversed Phase Material CharacteristicsPhase Particle Size
(µm)Pore Size
(Å)Surface Area
(m2/g)Carbon Load
(%)Bonding End Capping
strata-X 33 85 800 – – No
C18-E 55 70 500 17.0 trifunctional Yes
C18-U 55 70 500 18.0 trifunctional No
C18-T 55 140 300 15.0 trifunctional Yes
C8 55 70 500 10.5 trifunctional Yes
Phenyl 55 70 500 10.5 trifunctional Yes
CN 55 70 500 10.0 trifunctional No
SDB-L 100 260 500 – – No
15 Tel: 310-212-0555 Fax: 310-328-7768 Web: www.phenomenex.com
Normal Phases
Silica (Si-1)*Selectivity: unbonded surface results in hydrogen bonding, which gives strong retention mechanism for polar compounds.
• Extraction of polar compounds that are similar in structure.
CNSelectivity: dual selectivity toward polar and non-polar compounds combined with secondary polar silanol interactions.
• Normal phase sorbent that can effectively extract polar compounds from non-polar solvents.
• Extracting polar compounds that may be retained too strongly on Strata Si-1 such as hydroxyl or amino groups.
Florisil (Pesticide Residue)Selectivity: polar retention attributed to magnesium ion on the silica surface.
• Extraction of pesticides from environmental samples.
• Extraction of halogented compounds.
NH2Selectivity: retention mechanism of polar analytes by either hydrogen bonding or weak anion exchange.
• Extraction of strong anions from aqueous samples.
• Extraction of polar compounds similar in structure.
• Extracting polar compounds that may be retained too strongly on Strata Si-1 such as hydroxyl groups.
Normal Phase Material CharacteristicsPhase Particle Size
(µm)Pore Size
(Å)Surface Area
(m2/g)Carbon Load
(%)Bonding End Capping
Si-1 (Silica) 55 70 550 – – –
FL-PR (Florisil) 170 80 300 – – –
CN 55 70 500 10.0 trifunctional No
NH2 55 70 500 5.0 trifunctional No
*Silica is hydroscopic, any water adsorbed to the surface can greatly reduce the retention of organic solutes. It is important to keep silica sorbents dry and free from water.
16Tel: 310-212-0555 Fax: 310-328-7768 Web: www.phenomenex.com
17
Ion Exchange Phases
strata-X-C (patent pending)Selectivity: unique selectivity of strata-X plus strong cationexchanger to give mixed-mode retention of target analytes.
• Extraction of aromatic bases by π-π selectivity.
• Aggressive clean up of basic compounds from organic solvents.
• Fractionation of acidic and neutral components from basic analytes.
WCX (weak cation exchange)Selectivity: unique selectivity of carboxylic acid (CBA)bonded to silica surface.
• Extraction of quaternary amines.
• Extraction of strong cations.
SCX (strong cation exchange)Selectivity: surface bonded benzene sulfonic acid groupfor the retention of organic bases from biological andaqueous sample matrices.
• Extraction of 1°, 2° and 3° amines from biological fluids.
• π-π selectivity of benzene ring allows for some hydrophobic retention of analytes.
Screen-CSelectivity: incorporates the selectivity of a C8 plus astrong cation exchanger to give mixed-mode retention fortarget analytes.
• Extraction of basic drugs from biological matrices such as blood, serum and urine.
• Available in gravity flow format, 200 µm particle size (Screen-C GF) for viscous samples such as horse urine and plasma.
SAX (strong anion exchange)Selectivity: unique selectivity of a quaternary amine always charged which allows for retention of analytes from biological and aqueous matrices.
• Extraction of organic acids.
• Extraction of biomolecules.
WAX (weak anion exchange)Selectivity: NH2 bonded to silica surface to give retentionmechanism by either hydrogen bonding or weak anionexchange.
• Extraction of strong ions from aqueous solvent.
• Extraction of biomolecules.
Screen-ASelectivity: incorporates the selectivity of a C8 plus a strong anion exchanger to give mixed-mode retention for target analytes.
• Extraction of acidic drugs from biological matrices such as blood, serum and urine.
Ion Exchange Phase Material CharacteristicsPhase Particle Size
(µm)Pore Size
(Å)Surface Area
(m2/g)Carbon Load
(%)Bonding End
CappingpKa Ionic Capacity
(meq/g)
strata-X-C 33 85 800 – – – <1.0 1.0
WCX 55 70 500 8.0 trifunctional No 4.5 0.8
SCX 55 70 500 9.0 trifunctional No <1.0 0.9
Screen-C 55 70 500 proprietary trifunctional – <1.0 proprietary
Screen-C GF 200 70 500 proprietary trifunctional – <1.0 proprietary
SAX 55 70 500 6.5 trifunctional No Alwayscharged
0.9
NH2 (WAX) 55 70 500 5.0 trifunctional No 9.8 1.3
Screen-A 55 70 500 proprietary trifunctional – Alwayscharged
proprietary
Ansys Captiva® and Bond Elut Certify® are registered trademarks of Varian Inc. Xtrackt® is a registered trademark of United Chemical Technologies Inc. Empore™ is a trademark of 3M. Strata™, Sepra™ and Zebron™ are a trademark of Phenomenex Inc. Luna® is a registered trademark of Phenomenex Inc. Phenomenex is in no way affiliated with Varian, United Chemical Technologies Inc., or 3M. Applications shown may not be representative of all SPE applications.
Tel: 310-212-0555 Fax: 310-328-7768 Web: www.phenomenex.com
18
Strata™ SPE TubesIf Strata SPE or Sepra Bulk products do not perform as well or better than your current SPE product of similar phase, mass and size, send in your comparative data within 45 days and keep the Strata SPE products or Sepra Bulk for FREE!
SPE ReferenceManual & User GuideCD-Rom VersionOrder No.: AA0-6068Price: Hard Copy VersionOrder No.: AA0-6067
Price:
Note: tube sizes not proportional nor actual size.
?DEEN
PLE
H
Phenomenex technical consultants are available to help with your SPE method development. Please feel free to contact us or visit www.phenomenex.comfor SPE:
n Troubleshooting
n Technical Solutions
n Converting Liquid/LiquidExtraction to SPE
n Method Optimization
Ordering Information
Strata Tubes
1mL (100/box) 3mL (50/box) 6mL (30/box)
Phase 50mg 100mg 100mg 200mg 500mg 500mg 1g
SDB-L — 8B-S014-EAK — 8B-S014-FBJ 8B-S014-HBJ 8B-S014-HCH 8B-S014-JCH
C18-E 8B-S001-DAK 8B-S001-EAK 8B-S001-EBJ 8B-S001-FBJ 8B-S001-HBJ 8B-S001-HCH 8B-S001-JCH
C18-U — 8B-S002-EAK — 8B-S002-FBJ 8B-S002-HBJ 8B-S002-HCH 8B-S002-JCH
C18-T — 8B-S004-EAK — 8B-S004-FBJ 8B-S004-HBJ 8B-S004-HCH 8B-S004-JCH
C8 — 8B-S005-EAK — 8B-S005-FBJ 8B-S005-HBJ 8B-S005-HCH 8B-S005-JCH
Phenyl — 8B-S006-EAK — 8B-S006-FBJ 8B-S006-HBJ — 8B-S006-JCH
SCX — 8B-S010-EAK 8B-S010-EBJ 8B-S010-FBJ 8B-S010-HBJ 8B-S010-HCH 8B-S010-JCH
WCX — 8B-S027-EAK — 8B-S027-FBJ 8B-S027-HBJ 8B-S027-HCH 8B-S027-JCH
SAX — 8B-S008-EAK 8B-S008-EBJ 8B-S008-FBJ 8B-S008-HBJ 8B-S008-HCH 8B-S008-JCH
NH2 — 8B-S009-EAK — 8B-S009-FBJ 8B-S009-HBJ 8B-S009-HCH 8B-S009-JCH
CN — 8B-S007-EAK — 8B-S007-FBJ 8B-S007-HBJ 8B-S007-HCH 8B-S007-JCH
Si-1 — 8B-S012-EAK — 8B-S012-FBJ 8B-S012-HBJ 8B-S012-HCH 8B-S012-JCH
Florisil — — — — 8B-S013-HBJ 8B-S013-HCH 8B-S013 -JCH
Tel: 310-212-0555 Fax: 310-328-7768 Web: www.phenomenex.com
19
Strata™ Giga™ Tubes
Benefits of Strata Giga Tubes • Large analyte capacity• Available in 12, 20, 60, and 150mL tube sizes for large volume samples• Pre-packed sorbent bed for consistent recoveries• Great alternative to Varian Mega Bond Elut Flash® and ISOLUTE® Flash columns • Can be used to directly scale-up from smaller SPE formats
Note: tube sizes not proportional nor actual size.*Available in 50g and 70g/150mL formats
Strata Giga Tube Ordering Information
12mL (20/box) 20mL (20/box) 60mL (16/box)
Phase 100mg 500mg 1g 2g 1g 5g 10g 20g
C18-E — 8B-S001-HDG — 8B-S001-KDG — 8B-S001-LEG 8B-S001-MFF 8B-S001-VFF
C8 — — — 8B-S005-KDG — 8B-S005-LEG 8B-S005-MFF —
Phenyl — — — 8B-S006-KDG — 8B-S006-LEG 8B-S006-MFF —
SCX — 8B-S010-HDG — 8B-S010-KDG — 8B-S010-LEG 8B-S010-MFF 8B-S010-VFF
SAX — 8B-S008-HDG — 8B-S008-KDG — 8B-S008-LEG 8B-S008-MFF 8B-S008-VFF
NH2 — 8B-S009-HDG — 8B-S009-KDG — 8B-S009-LEG 8B-S009-MFF 8B-S009-VFF
CN — — — 8B-S007-KDG — 8B-S007-LEG 8B-S007-MFF —
Si-1* — 8B-S012-HDG — 8B-S012-KDG — 8B-S012-LEG 8B-S012-MFF 8B-S012-VFF
Florisil — — — 8B-S013-KDG — 8B-S013-LEG 8B-S013-MFF —
strata-X — 8B-S100-HDG 8B-S100-JDG — 8B-S100-JEG — — —
strata-X-C 8B-S029-EDG 8B-S029-HDG 8B-S029-JDG — — — — —
A. Silica-based
Giga Format 500mg/12mL 2g/12mL 5g/20mL 10g/60mL 20g/60mL
Retention Capacity† 25mg 100mg 250mg 500mg 1000mg
Suggested Elution Volume† 5mL 20mL 50mL 100mL 200mL
B. Polymeric-based
Giga Format 100mg/12mL 500mg/12mL 1g/12mL 1g/20mL
Retention Capacity† 15mg 75mg 150mg 150mg
Suggested Elution Volume† 2mL 10mL 20mL 20mL
†Retention capacities and elution volumes are specific to the chemical nature of the analyte being extracted, its concentration in the sample, the chemical nature of the eluting solvent and the bed mass used. The above are only guidelines. An elution study should be conducted. As a general rule of thumb recommended solvent wash and elution volumes for silica-based material should be 150µL per 100mg of sorbent and 200µL per 100mg of polymeric sorbent. ISOLUTE® Flash columns are registered trademarks of Argonaut Technologies Inc. Varian Mega Bond Elut® is a registered trademark of Varian Inc.
New Format
Tel: 310-212-0555 Fax: 310-328-7768 Web: www.phenomenex.com
Strata Method Development 96-well plate • Each Strata 96-well plate contains six silica-based sorbents and
two polymeric resins. One row of C18-E, C18-U, C18-M, C18-T, C8, phenyl (50mg/well) and strata-X and SDB-L (30mg/well) for parallel screening.
Order No. Unit/box Price
KS0-7293 1
96-well plate AccessoriesOrder No. Description Unit Price
Manifold
AH0-7284 96-Well Plate Manifold, Acrylic 1 ea
Sealing Mats
AH0-7195 Pierceable sealing mats, 96 square well 50/pk
AH0-7362 Sealing tape pad 10/pk
Collection Plates
AH0-7192 0.35mL/well 96 square well collection plate 50/pk
AH0-7193 1mL/well 96 square well collection plate 50/pk
AH0-7194 2mL/well 96 square well collection plate 50/pk
AH0-7408 Solvent waste reservoir tray 25/pk
Ordering Information
Strata 96-well plate 2 Plates/Box
Manifold Replacement Gaskets available, contact your Phenomenex Technical Consultant.
96-Well Plates
20
Phase 5mg 10mg 15mg 25mg 30mg 50mg 60mg 100mg
strata-X-C — 8E-S029-AGB — — 8E-S029-TGB — 8E-S029-UGB —
strata-XSDB-L
8E-S100-NGB—
8E-S100-AGB—
——
—8E-S014-CGB
8E-S100-TGB—
—8E-S014-DGB
8E-S029-UGB—
——
— —
Screen-CScreen-A
——
——
——
8E-S016-CGB8E-S019-CGB
——
8E-S016-DGB8E-S019-DGB
——
——
C18-EC18-UC8PhenylNH2
CNWCXSCXSAXSi-1
——————————
——————————
8E-S001-BGB—————————
8E-S001-CGB—
8E-S005-CGB8E-S006-CGB8E-S009-CGB8E-S007-CGB8E-S027-CGB8E-S010-CGB8E-S008-CGB8E-S012-CGB
——————————
8E-S001-DGB8E-S002-DGB8E-S005-DGB8E-S006-DGB8E-S009-DGB8E-S007-DGB8E-S027-DGB8E-S010-DGB8E-S008-DGB8E-S012-DGB
——————————
8E-S001-EGB—
8E-S005-EGB8E-S006-EGB8E-S009-EGB8E-S007-EGB8E-S027-EGB8E-S010-EGB8E-S008-EGB8E-S012-EGB
Compatible with most liquid handling systems and robotic workstations
Tel: 310-212-0555 Fax: 310-328-7768 Web: www.phenomenex.com
Sepra™
Sepra is a high performance bulk SPE sorbents. Works well for applications such as MSPD*(matrix solid phase dispersion) in which drugs of interest are separated from homogenized animal tissue or food sources, and can also be used for flash analysis to effectively purify organic compounds. Overall Sepra sorbents are:
• Economical
• Rugged
• Available in polar and non-polar phases for wide range of selectivity
• Available in gram to multi-kilogram quantities
If Sepra Bulk products do not perform as well or better than your current SPE product of similar phase, mass and size, send in your comparative data within 45 days and keep the Sepra Bulk for FREE!
*Interested in MPSD for your analysis? Please contact your Phenomenex Technical Consultant for technique and accessory information.
Sepra Material CharacteristicsPhase Particle
Size (µm)
Pore Size(Å)
Surface Area
(m2/g)
Carbon Load
%
Bonding End Capping
pH Stability
Ionic Capacity (meq/g)
Reversed Phase
C18-E C18-T C8Phenyl CN SDB-L
505050505095
65140656565225
520300520520520520
trifunctionaltrifunctionaltrifunctionaltrifunctionaltrifunctional
—
YesYesYesYesNoNo
1 to 81 to 81 to 81 to 81 to 8
1 to 14
——————
Normal Phase
Silica FL-PR (Florisil)
50165
6575
300300
——
NoNo
1 to 81 to 8
——
Ion Exchange
SCX SAXNH2
505050
656565
520520520
trifunctionaltrifunctionaltrifunctional
NoNoNo
1 to 81 to 81 to 8
0.90.91.3
Sepra Ordering InformationPhase 100g Price 1kg Price
Reversed Phase
C18-E C18-T (wide pore)C8Phenyl CN SDB-L
04G-434804G-440504G-440604G-440704G-440904G-4412
04K-434804K-440504K-440604K-440704K-440904K-4412
Normal Phase
Silica FL-PR (Florisil)
04G-441004G-4411
04K-441004K-4411
Ion Exchange
SCX SAXNH2
04G-441304G-441404G-4408
04K-441304K-441404K-4408
17.015.010.510.59.8—
——
9.06.55.0
21 Tel: 310-212-0555 Fax: 310-328-7768 Web: www.phenomenex.com
Vacuum Manifolds
Vacuum Manifold Replacement Parts
Adaptor Caps
Waste Container
Polypropylene Needles
Collection Racks
Stopcocks
24 – Position Vacuum Manifold
AH0-6024
SPE 24-Position Vacuum Manifold, Complete Assembly for 1 eafor 1, 3, 6mL Tubes
12 – Position Vacuum Manifold
AH0-6023
SPE 12-Position Vacuum Manifold,Complete Assembly 1 ea for 1, 3, 6mL Tubes
10 – Position Vacuum Manifold
AH0-7502
SPE 10-Position Tall-Boy Vacuum Manifold Complete Assembly 1 ea for Giga Tubes
SPE Accessories
Ordering InformationOrder No. Description Unit Price
24 – Position Vacuum Manifold Replacement Parts
AH0-6026AH0-6028AH0-6030AH0-6032AH0-6038
SPE Glass ChamberSPE Cover, Gasket and 24 StopcocksSPE GasketsSPE Vacuum GaugeSPE Collection Rack, including shelves, legs, clips and posts
eaea
2/pkeaea
AH0-6041AH0-6044
SPE Plate for 13mm Test TubeSPE Plate for 16mm Test Tube
eaea
AH0-6049AH0-6051
SPE StopcocksSPE Drying Attachment
24/pkea
12 – Position Vacuum Manifold Replacement Parts
AH0-6025AH0-6027AH0-6029AH0-6031AH0-6037
SPE 12-Position Glass ChamberSPE Cover, Gasket and 12 StopcocksSPE GasketsSPE Vacuum Gauge, Valve and Glass ChamberSPE Collection Rack, including shelves, legs, clips and posts
eaea
2/pkeaea
AH0-6040AH0-6043AH0-6042AH0-6045AH0-6046AH0-6047
SPE Plate for 13mm Test TubeSPE Plate for 16mm Test TubeSPE Plate for Volumetric FlaskSPE Plate for Autosampler VialSPE Plate, DimpleSPE Plate, Base
eaeaeaeaeaea
AH0-6048AH0-6050AH0-6052
SPE StopcocksSPE Drying AttachmentSPE 12-Position Vacuum Waste Container, polyproplyene
12/pkea
10/pk
10 – Position Vacuum Manifold Replacement Parts
AH0-7503 SPE 10-Position Tall-Boy Vacuum Manifold Glass Chamber ea
AH0-7504 SPE 10-Position Tall-Boy Vacuum Manifold Cover, Gasket and 10 Stopcocks
ea
General Vacuum Manifold Accessories
AH0-6033AH0-6034AH0-6035AH0-6036
SPE Manifold Needles, polypropyleneSPE Manifold Needles, polypropyleneSPE Manifold Needles, stainless steelSPE Manifold Needles, stainless steel
12/pk24/pk12/pk24/pk
AH0-6053AH0-6054
Female Luer FittingsMale Luer Fittings
2/pk2/pk
AH0-6055AH0-6056
Support Posts for RackLegs for Cover, black
3/pk4/pk
AH0-6057AH0-6058AH0-6059
Vacuum Gauge and Valve AssemblyValve Assembly OnlyVacuum Gauge Only
eaeaea
AH0-6060AH0-6061
Retaining ClipsVacuum Manifold Plugs
12/pk50/pk
AH0-6062AH0-6063
Control Valve, Teflon®
Control Valve, Teflon®
25/pk50/pk
AH0-6064AH0-6065
Teflon® NeedlesTeflon® Needles
100/pk500/pk
AH0-7191AH0-7378AH0-7379
Adaptor Caps for 1, 3 and 6mL SPE tubesAdaptor Caps for 12 and 20mL SPE tubesAdaptor Caps for 60mL SPE tubes
15/pk5/pk5/pk
22
Use an adaptor cap to attach an empty SPE tube.
Adaptor Cap(AH0-7191)
Tel: 310-212-0555 Fax: 310-328-7768 Web: www.phenomenex.com
����������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������
������������������������������������������������������������������������������������������
�����
���������
������
����������������������������������������������������������������������������������������������������������������
���������������������������������������������������������������������������������������������
���������������������������������������������������������������������������������������������������������������������������������������
�����������������������������������������������������
�������������������������������������������������
���������������������������������������������������������������������������������������������
�������������������������������������������������������������������������������������������������
SM
2242